Professional Documents
Culture Documents
Hydroleduc Accu Us
Hydroleduc Accu Us
Hydroleduc Accu Us
DIAPHRAGM
BLADDER
BLADDER-DIAPHRAGM
PISTON
2 Contents
Operating principle, functions and characteristics. 4
Technical description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Dimensions and characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Order code system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Hydraulic and gas connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
ACS(L) low temperature version. . . . . . . . . . . . . . . . . . . . . . . . . . 10
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
AS Spherical accumulators . . . . . . . . . . . . . . . . . . . . 12
HYDROPNEUMATIC
Technical description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
ACCUMULATORS
BLADDER, DIAPHRAGM Characteristics and dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . 13
BLADDER-DIAPHRAGM, Order code system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
PISTON Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Technical description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Characteristics and dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Order code system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Safety blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Pressure relief valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Charging equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Safety precautions & maintenance recommendations.29
The complete LEDUC product range. . . . . . . . . . . . . . 30
The LEDUC hydropneumatic accumulators range 3
ACS(L)
ACS(L) series
▪ Nitrogen capacities from 0.18 to 1.06 gallons (0.7 to 4 litres)
▪ Maximum pressure 4786 psi (330 bar) depending on model
▪ Extreme operating temperatures (standard): -4°F to +212°F (-20°C to +100°C)
▪ Low temperature version: -40°F to +212°F (-40°C to +100°C)
AS
AS series
▪ Nitrogen capacities from 0.005 to 2.64 gallons (0.02 to 10 litres)
▪ Maximum pressure 5800 psi (400 bar) depending on model
▪ Extreme operating temperatures (standard): -4°F to +248°F (-20°C to +120°C)
ABVE
ABVE series
▪ Nitrogen capacities from 1.06 to 13.21 gallons (4 to 50 litres)
▪ Maximum pressure 4786 psi (330 bar) depending on model
▪ Extreme operating temperatures: -4°F to +176°F (-20°C to +80°C)
APL
APL series
▪ Nitrogen capacities from 0.04 to 1.06 gallons (0.16 to 4 litres)
▪ Maximum pressure 3626 psi (250 bar) depending on model
▪ Extreme operating temperatures: -4°F to +176°F (-20°C to +80°C)
4 Operating principle, functions and characteristics
FUNCTIONS
► Surge control
The accumulator takes in the cinetic energy produced by a moving
column of fluid when the circuit is suddenly shut off (valve, solenoid etc.),
or more generally, when there is a sudden change in circuit pressure.
► Th ermal expansion
The increase in volume due to increased temperature will be absorbed
by the LEDUC accumulator.
► Shock absorbing-suspension
LEDUC accumulators, in a shock absorbing function, reduce fatigue of
hydraulic and mechanical components.
Examples: lifts, forklift trucks, agricultural machinery, construction
equipment, etc.
► Pulsation dampening
Adding a LEDUC accumulator to a hydraulic circuit smooths out any
flow irregularities from the pumps. This leads to better operation of the
system, protection of the components and thus increased service life,
and reduced noise levels.
Example: dosing pumps.
► Transfer of fluid
The LEDUC accumulator makes it possible to transfer hydraulic
pressure between two incompatible fluids, via the diaphragm which
separates the two fluids.
Examples:
transfer between hydraulic fluid and sea water,
test bench, etc.
► Energy storage
In a circuit under pressure, the LEDUC accumulators mean a reserve of
fluid may be kept permanently available. Thus a large amount of energy,
accumulated by a low power system during periods of low or no usage,
can be used in a very short time and within one cycle.
Examples:
automatic machines,
braking or declutching of vehicles or construction equipment,
emergency completion of working cycle in case of failure of main
power source.
CHARACTERISTICS
Capacity for total discharge Yes No, except particular conditions Yes, in particular conditions Yes
Suitable
Use with special fluids Limited Limited Limited
(special seals)
► Technical description
P2 V2
P1 V1
P0 V0
Mineral-based hydraulic fluids.
Other fluids: please ask.
► Examples of applications
En e rg y stor age
► Filling gas
Nitrogen only.
(1)
M28 x 1 5
ACS(L) series
7 87 (200)
Charging screw or valve
0 53 (13 5)
Ø 4 25 (108) (ACSL)
Ø 4 5 (114 3) (ACS)
Bladder diaphragm
A
Anti-extrusion stud
(2)
B
Ø 1 46 (37) (ACSL)
Ø 2 20 (56) (ACS)
For ACS 0.7 L, or ACS(L) low temperature version 104°F (-40°C), please refer to the tables on page 10. For other accumulators, make your choice
as a function of the possible combinations, using the columns below, and use the code in the far right-hand column.
Accumulator type
ACSL ACS ACSL ACS ACSL ACS ACSL ACS ACSL ACS ACSL
ACS 330 bar ● ● ● ● ● ACS
01
ACSL 250 bar ● ● ● ● ● ● ACSL
Volume (L)
02 0.7 1 1.5 2 2.5 4
Operating temperature
03 -20 +100°C ACSL ACS ACSL ACS ACSL ACS ACSL ACS ACSL ACS ACSL S
G3/8" G1
G1/2" ● ● ● ● ● ● ● ● ● ● G2
G3/4" ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● G3
04
M16 x 1.5 M1
M18 x 1.5 ● ● ● ● ● ● ● ● ● ● ● ● M2
3/4 - 16 UNF ● ● ● ● ● ● ● ● ● ● ● ● ● ● U1
1 1/16" - 12 UN ● ● ● ● ● ● ● U2
Charging screw
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● V
M28 x 1.5
05 P1620 valve
● ● ● ● ● ● ● ● ● ● ● ● ● W
(M16x200)
SCHRADER valve
● ● ● ● Y
(8V1)
Without protection
(P1620, SCHRADER)
06 ● ● ● ● ● ● ● ● ● ● ● N
Plastic plug
(Screw M28 x1.5)
Without connection ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● N
Male connection
● ● ● ● ● ● ● M
M33 x 1.5 - G1/2"
07 Male connection
● ● ● ● ● ● ● D
M18 x 1.5
Male connection
● ● ● ● ● ● ● E
M27 x 2
Male connection
● ● ● ● ● ● ● J
G3/8’’
Charging pressure
08 Specify the charging pressure (in bar)
ACS(L) Fluid and gas connections 9
Code
ACS(L) series
Implantation following ISO 1179 Implantation
Implantation Øfollowing
B SAEISO
following J5141179 Implantation following SAE J514
ISO 9974 04 ISO 9974 Code
ØB
04
G1 G3/8’’
U1 3/4-16UNF - 2B
G2 G1/2’’
U2 1’’1/16 - 12UNF - 2B
B G3 G3/4’’ B B B
B see order code system code 4
M1
B seeBorder
M
see order16 x 1,5
code
code systemsystem
code 4code 4 B see order code system code 4
M2 M 18 x 1,5
V W Y
M28 x 1 5
1 42 (36)
Ø 0 78 (20)
0 77 (19 6)
M8
0 53 (13 5)
0 53 (13 5)
0 53 (13 5)
36 on flats
M28 x 1 5
36 on flats
N P P P
36 on flats
Ø 0 78 (20)
36 on flats
M28x1 5
36 on flats
M28 x 1 5
36 on flats
M28 x 1 5
1 41 (36)
2 36 (60)
M8
0 77 (19 6)
M8
1 73 (44)
0 53 (13 5)
0 94 (24)
0 53 (13 5)
0 53 (13 5)
0 53 (13 5)
N M D E J
ØB ØB ØB
C3 on flats
C3 on flats
C3 on flats
C2
C2
ØB
C2
C1
0 63 (16)
C1
C1
ØC ØC
ØD
ØC Ø C Male, for implantation following ISO 6149 Ø C Male, for implantation following ISO 1179 (Form E)
Code
ØB ØC C1 C2 C3 D
07
Code
N - - - - -
04
M G1/2’’ M33 x 1.5 0.78 (20) 0.47 (12) 1.61 (41) G1/2’’
D G1/2’’ M18 x 1.5 0.49 (12.5) 0.61 (15.5) 1.06 (27) -
E G1/2’’ M27 x 2 0.55 (14) 0.63 (16) 1.26 (32) -
J G1/2’’ G3/8’’ 0.47 (12) 0.61 (15.5) 1.06 (27) -
10 ACS and ACSL Low temperature version -40°F
The ACS(L) low temperature models accumulators are equiped with a hydrogenated nitrile diaphragm (ref. E/7).
► ACS 0.7
066695 0.18 (0.7) 4786 (330) 9 (4) 6.89 (175) G1/2" / M33 x 1.5 MALE screw
ACS(L) Accessories 11
5 47 (139)
AC C ES S O R I E S 3 42 (87)
Série ACS(L)
1 57 (40)
0 35 (9)
► ACS(L) adjustable clamps 1 38 (35) 0 95 (24)
00 0 51 (13)
6( 3 54 (90)
1,5
Volume Code )
Caracteristics Ø4 25 to 4 67
(L) LEDUC
M8
(108 to Ø 118 5)
Zinc-plated steel 254021
2 87 (73)
0.7 - 1 - 1.5 Zinc-plated steel
0 12 (3)
254031
2 - 2.5 - 4 quick-tightening
Stainless steel 254032 6 30 (160)
0 79 (20)
► ACS(L) fixed clamp
Ø 4 53 (115)
Volume Code
Caracteristics
(L) LEDUC
0.7 - 1 - 1.5 Zinc-plated steel C001028
3 54 (90)
1 77 (45)
Tightening torque of the fixation screws: 20 Nm.
M8 M8
5 (127)
►ACS(L) clamps
Ø0
Volume Code 31
Caracteristics (8 Ø 4 53 (115)
(L) LEDUC )
0.7 - 1 - 1.5 Zinc-plated steel C001031
2 - 2.5 - 4 Stainless steel C001032
2 95 (75)
1 97 (50)
M8
4 84 (123)
12 AS Spherical accumulators
► Technical description
The diaphragm only changes position, the elastomer in fact works little.
The LEDUC spherical accumulator owes most of its qualities to its
diaphragm and metal pin:
excellent gas/fluid tightness,
possibility of total and rapid discharge, P1 V1 P2 V2
can be adapted to suit a wide range of fluids hanged.
► Operating fluids
► Protection
On request, ARCOR® anti-corrosion treatment or paint.
► Tests and certifications
► After-sales service
HYDRO LEDUC provides after sales service, supplies spare parts and can
requalify your accumulators (retesting), only for the accumulators operated in
Tra n sfer France.
AS Characteristics, dimensions and accessories 13
CH A R A C T ER I S T IC S A N D D IME N SIONS
Charging valve
ØC
A
Diaphragm
D
E
B
ØF
AS series
Anti-extrusion stud
ØH
K
ØG
1 26 (32) on flats
Charging valve
1 42 (36)
0 40 (10)
4 41 (112)
Nitrogen Dimensions
Max.
LEDUC capacity Weight inches (mm)
AS pressure
code Vo gallons lbs (kg)
psi (bar) A B ØC D E ØF ØG ØH K
(litres)
ØC
AS 00 20 060932 0.05 (0.19) 5801 (400) 3 (1.2) 5.91 (150) 2.72 (69) 3.33 (84.5) 0.35 (9) 0.79 (20) 3.29 (83.5) 1.14 (29) G1/4" 0.47 (12)
0 47 (12)
0 39 (10)
AS 00 50 060972 0.12 (0.45) 5801 (400) 6 (2.8) 7.24 (184) 3.50 (89) 4.49 (114) 0.47 (12) 0.91 (23) 4.43 (113) 1.57 (40) G3/8" 0.36 (16)
A
AS 00 70 060782 0.17 (0.65) 3626 (250) 7 (3) 7.76 (197) 3.50 (89) 4.70 (119.5) 0.35 (9) 0.94 (24) 4.67 (119) 1.18 (30) G3/8" 0.51 (13)
G1/4" Diaphragm
D
AS 01 00 060110 0.29 (1.1) 5801 (400) 12 (5.5) 7.76 (197) 4.41 (112) 6.44 (163.5) 1.99 (50.5) 1.99 (50.5) 6.44 (164) 1.57 (40) M18 x 1.5 0.47 (12)
1 42 (36) on flats
E
AS 02 50 060812 0.66
Ø 1(2.55)
64 (41 8) 5801 (400) 31 (14) 9.88 (251) 6.34 (161) 8.41 (213.5) 1.46 (37) 1.14 (29) 8.27 (210) 2.01 (51) G3/4" 0.67 (17)
B
AS 04 00 060121 1.07 (4.1) 5801 (400) 49 (22) 11.73 (298) 7.95 (202) 9.88 (251) 1.73 (44) 1.57 (40) 9.72 (247) 4.13 (105) M33 x 2 0.79 (20)
AS 10 00 060141 2.65 (10.19) 5801 (400) 117 (53) 15.39 (391) 10.55 (268) 13.35 (339) Ø F 2.07 (52.5) 2.07 (52.5) 13.11 (333) 4.14 (105.1) M33 x 2 0.79 (20)
Anti-extrusion stud
AC 00 02 060955 0.004 (0.017) 5801 (400) 1 (0.640) see drawing
ØH
K
HYDRO LEDUC provides after sales service, supplies spare parts and can requalify your accumulators (retesting).
ØG
1 26 (32) on flats
1 42 (36)
0 40 (10)
4 41 (112)
0 47 (12)
0 39 (10)
G1/4"
1 42 (36) on flats
Ø 1 64 (41 8)
14 AS Spherical accumulators
Make your choice as a function of the possible combinations, using the columns below, and use the code in the far right-hand column.
Accumulator type
01 Spherical accumulator ● ● ● ● ● ● ● AS
Compact accumulator ● AC
Shell protection
Without protection ● ● ● ● ● ● ● ● N
03
ARCOR® treatment ○ ○ ○ ○ ○ ○ ○ ○ P
Diaphragm material
NBR ● ● ● ● ● ● E1
End stop adherized ● ○ ○ ● ○ ○ ○ ○ E1A
Stainless steel end stop ○ ○ ○ ○ ○ ○ E2
04
ECO (epichlorohydrin) ○ ○ E3
EPDM (epr) ○ ○ ○ ○ ○ E4
FKM (Viton®) ○ ○ ○ ○ ○ ○ E5
Charging valve
P1620 valve (M16x200) ● ● ● ● ● ● ● ● W
P1620 stainless steel valve
05 (M16x200) ○ ○ ○ ○ ○ ○ ○ ○ X
● Standard version
○ Special version on request.
15
AC C ES S O R I E S
M8
(108 to 118 5)
(L) LEDUC
Zinc-plated steel 254021
2 97 (73)
0 12 (3)
Zinc-plated steel
0.13 (0.5) - 0.17 (0.7) 254031
quick tightening
Stainless steel 254032 6 30 (160)
► Fixation clamps
AS series
Dimensions M12 x 65 8 8
1 18 (30)
Volume LEDUC 0 94 (24)
inches (mm) Characteristics 0 51 (13) ØD
gallons (Liters) code
ØD L1 L2
0.26 (1) 6.61 (168) 7.24 (184) 5.83 (148) Zinc-plated steel 254022
0 33 (8 5)
0.66 (2.5) 8.27 (210) 10 (254) 8.35 (212) Zinc-plated steel 254006
1.06 (4) 9.72 (247) 11.81 (300) 9.76 (248) Zinc-plated steel 254005
L1
► Technical description
The ABVE bottle type acccumulators consist of:
ABVE 4786 psi (330 bar)
a forged steel body, Maximum pressure: 4786 (330 bar)
a bladder, ABVE 4 maximum pressure: 5076 (350 bar)
a charging valve,
Extreme operating temperature:
an oil side orifice fitted with a poppet valve which prevents extru-
sion of the bladder, and an air bleed screw used during system Standard version: -4°F to +176°F (-20°C to +80°C)
start-up.
► Advantages
► Deformation of the bladder
Bladder accumulator component parts are interchangeable with those of
major accumulators available.
Dimensions allow for easy installation and also use in batteries.
P0V0 P1V1 P2V2
► Operating fluids
► Examples of applications
E nergy stora ge
► Filling gas
Nitrogen only.
► After-sales service
HYDRO LEDUC provides after sales service, supplies spare parts and can
requalify your accumulators (retesting) only for the accumulators operated in
France.
ABVE Characteristics, dimensions and accessories 17
CH A R A C T ER IS T IC S A N D D IME N SIONS
Charging valve
Bladder
ØC Poppet
valve
ØD 48
B ØE
39 5
Bleed screw
G1"1/4 G2"
(Dimensions in mm)
ØF
ABVE series
Nitrogen Dimensions
Max.
capacity Weight inches (mm)
ABVE pressure
Vo gal lbs (kg)
psi (bar) A B ØC ØD ØE ØF G
(litres)
ABVE 4 0.96 (3.7) 5076 (350) 28.66 (13) (417.4) 141.09 (64) 370.38 (168) 149.91 (68) 116.84 (53) G1 1/4" 144.18 (65.4)
ABVE 10 2.54 (9.6) 5076 (350) 71.65 (32.5) (575.4) 224.87 (102) 491.63 (223) 222.67 (101) 167.55 (76) G2" 144.18 (65.4)
ABVE 20 4.65 (17.6) 5076 (350) 99.20 (45) (878.4) 224.87 (102) 491.63 (223) 222.67 (101) 167.55 (76) G2" 144.18 (65.4)
ABVE 32 8.64 (32.7) 5076 (350) 176.37 (80) (1403.4) 224.87 (102) 491.63 (223) 222.67 (101) 167.55 (76) G2" 144.18 (65.4)
ABVE 50 12.92 (48.9) 5076 (350) 246.90 (110) (1926) 224.87 (102) 491.63 (223) 222.67 (101) 167.55 (76) G2" 144.18 (65.4)
18 ABVE Bladder accumulators
ABVE To obtain the code of your welded cylindrical accumulator ABVE, complete
the different parameters from 01 to 07 in the table on the left according to
01 02 03 04 05 06 07 the options you require (see table below).
Make your choice as a function of the possible combinations, using the columns below, and use the code in the far right-hand column.
Accumulateur type
01 ABVE ● ● ● ● ● ABVE
Volume (L)
02 04 10 20 32 50
Ø 50 mm ● S1
G2" ● ● ● ● G5
G2"G1" ● ● ● ● B
G2"full ● ● ● ● C
Charging pressure
07 Specify the charging pressure (in bar)
AC C E S S O R I E S
1 18 (30)
0 35 (9)
► Fixation clamps
30
0 51 L2 13 L2
9
(13)
M12x65 0 35 (8 8)
1 18 (30)
ØD ØD
1 36 (34 5) 1 36 (34 5)
Volume Dimensions (mm) M12x65 0 35 (8 8) M12x65
Characteristics Code
(L) ØD L1 L2 0 35 (8 8)
0 33 (8 5)
4 6.61 (168) 7.24 (184) 5.83 (148) 254022
0 33 (8 5)
10 - 20 Zinc-plated steel L1
8.70 (221) 10.16 (258) 8.50 (216) 254007 L1
32 - 50
254022 254007
► Fixation seats
59)
Volume Code 26 (1
0 98 (25)
3 15 (80)
25 (1
08) Ø6
Ø4
(L) LEDUC
25
1 57 (40)
2x
4 254012 Ø 0 67 (17)
63
0 5)
8 2 (160 (17 4x 35)
7 (2 ) 6 89 7
10 87 (2 5 (2
92
10 - 20 - 32 - 50 254008 10) Ø0 67 (17) 24 00
(26 )
0)
254012 254008
► Adaptors
Volume Dimensions Code
Characteristics A
(L) A B C (mm) LEDUC
G3/4" 0.63 (16) 066305
4 G1 1/4"
Full 0.63 (16) 066307 C
ABVE series
G3/4" 0.51 (13) Steel 066074
B
10 - 20 - 32 - 50 G2" G1" 0.75 (19) 066068
Full 0.75 (19) 066069
► Technical description
APL accumulators are designed with a high mechanical resistance
APL 5076 psi (350 bar)
Maximum pressure: 5076 (350 bar)
forged steel body. Extreme operating temperature:
The fluid-gas separating piston is equipped with seals adapted to:
Standard version: -4°F to 176°F (-20°C to + 80°C)
the fluids to convey,
For other temperatures, please consult us.
the operating temperature,
The APL accumulators can be fitted with a charging screw or charging
valve, and are a modern solution for the needs of hydraulic circuits.
APL 3626 psi (250 bar)
Maximum pressure: 3626 (250 bar)
► Advantages Extreme operating temperature:
Standard version: -4°F to 176°F (-20°C to + 80°C)
LEDUC APL piston accumulators, are designed: For other temperatures, please consult us.
to withstand very high volumetric ratios,
to ensure total and rapid discharge of fluid,
for assembly in any position,
to guarantee minimal nitrogen loss overtime,
for easy adaptation for use with different fluids and tempera- ► Movement of the piston
tures.
► Operating fluids
P1V1
P2V2
P0V0
Non-standard and/or corrosive fluids: please consult our
Customer Service Department.
► Example of applications
E nergy stora ge
► Filling gas
Nitrogen only.
► Charging
Two versions available:
with charging screw,
with charging valve.
► Tests and certifications
M28 x 1,5
Charging screw
or charging valve (1)
0 53 (13 5)
Ø 3 72 (94 6)
Ø 3 74 (95)
Piston
A
Ø (2)
Ø 1 46 (37)
Make your choice as a function of the possible combinations, using the columns below, and use the code in the far right-hand column.
Accumulator type
AP 350 bar ● ● ● - - ● ● - ● ● - ● - - - - - AP
01
APL 250 bar - - - ● ● - ● - ● - ● ● ● ● ● APL
Volume (L)
02 0,16 0,32 0,5 0,7 0,75 1 1,25 1,5 1,8 2 2,5 3 3,5 4
Type of seal
03 Double sealing ● ● ● ● ● ● ● ● ● ● ● ● ● ● D
Piston diameter
Ø 50 mm ● ● ● - - ● ● - ● ● - ● - - - - - 06
04
Ø 80 mm - - - ● ● - - ● - - ● - ● ● ● ● ● 08
05 9/16 - 18 UNF ● ● ● ● ● ● ● ● U0
3/4 - 16 UNF ● ● ● - - ● ● - ● ● - ● - - - - - U1
1"1/16 - 12 UNF - - - ● ● - - ● - - ● - ● ● ● ● ● U2
Charging pressure
09 Specify the charging pressure (in bar)
APL Connections and accessories 23
Code Code
Implantation following ISO 1179 ØImplantation
B SAE J514
Implantation following following ISO 1179 Implantation following SAE J514 ØB
05 05
G2 G1/2’’ U0 9/16 - 18 UNF- 2B
G3 G3/4’’ U1 3/4-16UNF - 2B
B B B B U2 1’’1/16 - 12UNF - 2B
V W N P P
36 on flats
M28X1 5
36 on flats
Ø 0 78 (20)
1 42 (36)
M28X1 5 M28X1 5
M8 M8
1 62 (36)
2 36 (60)
M8
0 53 (13 5)
0 53 (13 5)
0 94 (24)
0 53 (13 5)
0 53 (13 5)
0 53 (13 5)
M28x1 5
AC C E S S O R I E S F O R A P L
► Adjustable clamps
0 98 (25)
0 51 (13)
Volume Dimensions inches (mm)
Model Characteristics Code
gallons (L) A B C D E F G
Ø3.74 Zinc-plated steel C001026
to
Zinc-plated steel
3.74 C001033
0.13 to 1.06 2.60 6.30 3.54 3.42 1.38 1.57 quick tightening
APL
(0.5 to 4) (66) (160) (90) (87) (35) (40) 00
Ø95 6(
15
D
to Stainless steel C001027 ØA
)
E
100 M8
0 35 (9)
G
Ø2.36
B F
to
2.76 1.59 4.72 2.76 3.35 0.75 1.97 C
AP 0.16 to 1.8 Zinc-plated steel C002160 0 12 (3)
(40.5) (120) (70) (85) (19) (50)
Ø60
to 70
APL series
► Fixed clamps
DE SC R I P T I O N CODIFICATION
These safety and shut-off blocks are designed to bring together in To obtain the code of your safety block, complete the different parameters
a single block the necessary safety organs required for the correct from 01 to 06 in the table on the left according to the options you require
operation of hydraulic circuits incorporating accumulators. (see table below).
The basic block consists of: :
a ball valve with quarter turn closure, to isolate the accumulator
BS
from the circuit;
needle valve ensuring the manual decompression of the circuit; 01 02 03 04 05 06
relief valve (directly operated) set at the maximum operating pres-
sure of the accumulator. This relief valve should never be used as Make your choice as a function of the possible combinations, using the
a limiter to protect the hydraulic pump; columns below, and use the code in the far right-hand column.
the Q version is fitted with a one-way adjustable flow limiter.
Mounted on the main block, this limiter controls the accumulator Type
outlet flow, whilst inlet flow remains unrestricted. 01 Safety blocks BS
G3/4ʺ ● ● ● A
06
G1 ¼" ● ● ● B
G2ʺ ● ● ● ● C
*The pressure limiter setting is given for a flow at 13.21 gal/min (50 l/min).
6
Pressure loss (bar)
BS1
5
► Graph of pressure drop
as a function of flow 4
BS2
3
D I M EN S I O N S
89 A
A 0 9 (22 5) 3 15 (80)
0 70 3 30 (84)
7 30 (185 5)
M
(17 6)
1 38 (35)
2 83 (72)
2 (51)
T
1 93 (49)
3 15 (80)
0 7 (17)
1 26 (32)
T M
3 30 (84)
P P
G1/4’’ 2 84 (72 2) T
depth 0 47 (12) 1 38 (35) G1/4’’
Ø 1 30 (33) depth 0 10 (2 5)
P G3/4’’ depth 0 63 (16) depth 0 47 (12) 1 38 (35)
G3/4’’ depth 0 63 (16) 2 (50 5)
Ø 1 40 (35 5) depth 0 06 (1 5) 3 03 (77)
P
2 36 (60) 2 36 (60)
1 52 (38 5)
1 32 (33 5)
1 97 (50)
1 31 (33 4)
4xM10x1 5
1 97 (50)
A
depth 0 41 (10 5)
G2’’
1 85 (47)
1 85 (47)
185 5
0 95 (24)
M
0 81 (20 50)
0 61 (15 6)
T
4 72 (120)
G1’’1/4
3 31 (84)
G3/4’’
P
1 97 (50)
1 81 (46)
G1/4’’
depth 0 47 (12)
G3/4’’ depth 0 63 (16)
Ø 1 40 (35 5) depth 0 06 (1 5)
6 34 (161) 3 03 (77)
2 36 (60)
1 32 (33 5)
1 97 (50)
5 48 (139 1)
M 4x M14 x 0 08 (2)
1 90 (48)
depth 0 80 (20) M
T 4x M14 x 0 08 (2)
depth 0 80 (20)
(3 24
)
15
1
P
P 2 03 (51 6) 4
2 03 (51 6) 2 2 1 5)
(3
4 57 (116)
2 11 (53 5) 3 78 (96)
3 78 (96) G2’’
4 57 (116)
0 98 (25)
G2’’ A
3 78 (96) A
0 98 (25)
1 38 (35)
1 38 (35)
2 70 (68 5)
8 70 (221)
1 18 (30) 8 86 (225)
0 98 (25)
1 77 (45)
2 64 (67)
M
4 57 (116)
1 30 (33)
4 57 (116)
M
T 2 70
(68 5)
G3/8’’ T
depth 0 51 (13) 1 46 (37) G3/8’’
2 46 (62 5) depth 0 51 (13)
3 78 (96) 3 78 (96) 3 78 (96)
3 78 (96) 3 78 (96)
2 83 (72) 2 83 (72)
3 78 (96)
2 83 (72)
1 89 (48)
1 90 (48)
A A
3 78 (96)
2 83 (72)
DBDS cartridges
The pressure relief valve integrated in BS1 and BS2 safety blocks (see
pages 24 and 25) are designed to limit the maximum pressure of the
circuit to ensure it cannot exceed the maximum rated pressure of the
accumulator.
*The pressure limiter setting is given for a flow at 13.21 gal/min (50 l/min).
S4 S3 S2 S1
Ø D11
Ø D1
Ø 0 10 (2 5)
L1
► Dimensions
Type S1 S2 S3 S4 L1
0 05 A
01 A
L27
Size 6 1.26 (32) 1.18 (30) 0.75 (19) 0.24 (6) 2.83 (72) Ø D13
Ø D14
Size 10 1.42 (36) 1.18 (30) 0.75 (19) 0.24 (6) 2.68 (68)
T P
α
ØD12H9
Ø D15
A
90°
1 25
S4 S3 S2 S1
Ø D11
Ø D1
Ø 0 10 (2 5)
L1
► Dimensions
0 05 A
01 A
L27
Ø D13
Ø D14
T P
α
ØD12H9
ØD11
Ø D15
A
90°
1 25
T P
L21
L22 Ø D16
L23 0 5-45°
L24
L25
1 25
L28
Type Ø D11 Ø D12 Ø D13 Ø D14 Ø D15 Ø D16 L21 L22 L23 L24 L25 L27 L28 α
2.22
Size 6 M 28 x 1.5 0.98 (25) 0.24 (6) 0.59 (15) 0.98 (24.9) 0.24 (6) 0.60 (15) 0.75 (19) 1.18 (30) 1.38 (35) 1.78 (45) 2.56 (65) 15°
(56.5) ±5
2.66
Size 10 M 35 x 1.5 1.26 (32) 0.39 (10) 0.73 (18.5) 1.26 (31.9) 0.39 (10) 0.71 (18) 0.91 (23) 1.38 (35) 1.61 (41) 2.05 (52) 3.15 (80) 15°
(67.5) ±7
► Performance curves
Mesured at :
Viscosity v = 41 Cst
Temperature t = 122 °F (50°C).
SIZE 6 SIZE 10
Bar
Bar
Bar
0 050 0 0
25 25 30 60 50 80 120 30 60 80 120
Q [l/min] Q [l/min] Q [l/min] Q [l/min]
CH A R G I N G VA LV E S
The P 1620 universal valve exists in two versions:
P 1620: standard valve, thread M 16 x 200.
PX 1620: stainless steel valve, thread M 16 x 200.
Gas side
LEDUC Accumulator
Valve type Implantation Remark Charging device Adaptor
code type
A
310367 G 1/4 ACS-ACSL-AS-APL Standard
P1620
310379 M10 x 1.50 ABVE Standard M 16 x 2.00
VGL4
PX1620 310527 G 1/4 AS Stainless steel
V15N 310308 M10 x 1.50 ABVE Stainless steel 5/8’’ 18 UNF
M8 x 1.25
Screw 066542 with ring ACS - ACSL Standard VGL 4 None
BS 130331A
Ø 0 79 (20)
LEDUC B C on flats
code inches (mm) inches (mm)
310367 1.42 (36) 0.75 (19)
B
6 on flats M28x1 50
► Installing your accumulator: Check that the hydraulic installation is capable of withstanding the
maximum service pressure engraved on the accumulator. Check that
Before installation, it is essential to visually check the accumulator for
maximum service pressure of the accumulator never exceeds the maxi-
any external damage.
mum service pressure engraved on the shell and on the name plate.
For optimal operation, the accumulator should be placed as close as
possible to the application. It should be installed in a vertical position
Volumetric ratio (V0-V2/V0) must not be exceeded, see page 5.
with the charging valve or screw at the top. For use in a horizontal posi-
tion, please contact our Technical Department. The accumulator should
Bleed the pipework of any air.
be installed in an easily accessible place and be fixed using robust
collars , a seat etc. ► Maintenance:
It is strictly forbidden to make any modification to the Before intervening on any circuit which has a gas filled pressure
accumulator (welding, grinding, machining etc.), or to change the vessel, the pressure must be discharged from the circuit.
information engraved on the accumulator. Check nitrogen pressure during the first few weeks of operation
and adjust the frequency of checks depending on application.
The circuit should include an isolation valve to isolate Ensure at every check that the accumulator has been isolated
the accumulator, and also a means of checking that the from the circuit, and that there is no more pressure in fluid side.
hydraulic pressure never exceeds the maximum service 1
Use the charging and gauging device VGL reference 066660
pressure engraved on the accumulator. The accumu- (see page 28).
lator must be connected to a relief valve set at the 5
Be careful to use a manometer with a measuring range compati-
accumulator’s maximum authorized service pressure.
All of these functions are ensured by HYDRO LEDUC 2
3 ble with the nitrogen pressure to be checked.
safety and shut-off blocks BS1M and BS2M
4
Visually inspect the accumulator regularly for any signs of deteri-
(see pages 24-25). oration such as corrosion, deformation etc.
For cleaning recommendations and precautions : please contact
Check that the fluid is compatible with the materials used in the our Technical Department.
accumulator: the shell, elastomer, and the fluid used for the hydraulic For spare parts, only use LEDUC parts.
testing. The user is not authorized to change any part of the acuumulator
Suitable fluid : mineral-based hydraulic fluid or equivalent. without the manufacturer’s prior approval. An accumulator is
For other fluids, please consult our Technical Department. made up of sub-assemblies. Any modification not authorized
► Start up: by the manufacturer and its notified body invalidates the CE
certification of the whole accumulator.
Accumulators are supplied either with a pre-charge pressure for storage of
around 5 bar, or with pre-charge pressure as specified and corresponding ► Legislation
to the requirement calculated depending on working conditions. The pre-
Hydraulic accumulators are gas pressure vessels.
charge pressure is engraved on the accumulator shell.
The manufacture of such products must conform to Directive 2014/68/UE.
Pre-charge pressure of LEDUC accumulators (all sizes).
Local regulations and legislation must be strictly respected regarding the use of
For all pre-charge pressures greater than or equal to 20 bar, the tolerance accumulators.
is -29/+87 psi (-2/+6 bar).
For a tighter tolerance, please contact our Technical Department. ► Pressure Equipment Directive (PED) 2014/68/EU
All pre-charge pressures done by HYDRO LEDUC are adjusted at ambiant LEDUC accumulators of less than 1 litre capacity are supplied with a
temperature of 68°F (20°C). manufacturer’s certificate. They cannot be stamped CE, but conform to the
Pre-charge pressure should be checked before start-up : see the Directive 2014/68/UE.
recommendations sheet supplied with each accumulator. LEDUC accumulators of 1 litre capacity or more are supplied with a Certificate
Check pre-charge pressure, or charge to required pressure level, UE of conformity. They bear the CE stamp and the reference of the official
organisation certifying their conformity.
using the charging and gauging device (see page 24), see also
Use of these accumulators in France is governed by decree dated 15 March
instructions supplied with the device. The influence of tempera- 2000 (Official Bulletin n°96).
ture on pre-charge pressure must be taken into consideration.
Please note that a slight loss of nitrogen is possible when check- ► Useful addresses:
ing pre-charge pressure.
-- French legislation and application of directive 2014/68/UE:
It is strictly forbidden to use any gas containing oxygen or an air http://www.adminet.com/jo
compressor which would lead to danger of explosion. -- European legislation: http://europa.eu.int
Use only bottled dry nitrogen.
Independent approved organisations: APAVE, TÜV, VERITAS...
M/MA
MSI
X Pi/XAi TXV
D ELTA
index able Va r i a b l e
m o to r
HYDRO LEDUC offers 3 types of piston pumps The W range is composed of fixed Fixed and variable displacement piston motors
perfectly suited to all truck and PTO-mount displacement pumps, and the DELTA range, of Models from 0 31 to 11 02 cu in/rev
applications variable displacement pumps. These pumps (5 to 180 cc/rev)
can operate at high pressures within minimal Available in DIN and SAE versions
Fixed displacement from 0 73 to 7 93 size. In fixed displacement, special drainless
cu in/rev (12 to 130 cc/rev) motor
► W and WA (SAE)* pumps:
Fixed displacement, twin-flow,
from 2x 1.53 to 4.58 cu.in Fixed displac. from 0 73 to 7 65 cu in/rev
( 2x25 to 2x75 cc/rev) (12 to 125 cc/rev)
Variable displacement, with LS control ISO 3019/2 or SAE flanges.
(load sensing) from 2 44 to 9 15 cu in/ DIN 5480 or SAE shafts.
rev (40 to 150 cc/rev)
► DELTA pumps:
Variable displac. from 2 44
to 5 61 cu in/rev (40 to 92 cc/rev)
SAE shafts and flanges.
H Y D R O P N E U MAT IC M ICRO
A C C U M U LATO R S HYDRAULICS
µ
A passion for hydraulics
HYDRO LEDUC AB
Betongvägen 11
461 38 TROLLHÄTTEN
SWEDEN
Tel. 46 (0) 520 10 820
HYDRO LEDUC BV
Graaf Engelbertlaan 75
4837 DS Breda
THE NETHERLANDS
+31 6 202 40 651
www.hydroleduc.com contact@hydroleduc.com
US_ACCUS_20180420