Hydroleduc Accu Us

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 32

HY DR OPN EU M AT IC ACCUMULATORS

DIAPHRAGM
BLADDER
BLADDER-DIAPHRAGM
PISTON
2 Contents
Operating principle, functions and characteristics. 4

ACS(L) Welded accumulators. . . . . . . . . . . . . . . . . . . 6

Technical description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Dimensions and characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Order code system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Hydraulic and gas connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
ACS(L) low temperature version. . . . . . . . . . . . . . . . . . . . . . . . . . 10
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

AS Spherical accumulators . . . . . . . . . . . . . . . . . . . . 12
HYDROPNEUMATIC
Technical description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
ACCUMULATORS
BLADDER, DIAPHRAGM Characteristics and dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . 13
BLADDER-DIAPHRAGM, Order code system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
PISTON Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

ABVE Bladder accumulators. . . . . . . . . . . . . . . . . . . 16

Technical description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Characteristics and dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Order code system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

AP(L) Piston accumulators. . . . . . . . . . . . . . . . . . . . . 20


Technical description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Characteristics and dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Order code system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Accessoires. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Safety blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Pressure relief valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Charging equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Safety precautions & maintenance recommendations.29
The complete LEDUC product range. . . . . . . . . . . . . . 30
The LEDUC hydropneumatic accumulators range 3

ACS(L)

ACS(L) series
▪ Nitrogen capacities from 0.18 to 1.06 gallons (0.7 to 4 litres)
▪ Maximum pressure 4786 psi (330 bar) depending on model
▪ Extreme operating temperatures (standard): -4°F to +212°F (-20°C to +100°C)
▪ Low temperature version: -40°F to +212°F (-40°C to +100°C)

AS

AS series
▪ Nitrogen capacities from 0.005 to 2.64 gallons (0.02 to 10 litres)
▪ Maximum pressure 5800 psi (400 bar) depending on model
▪ Extreme operating temperatures (standard): -4°F to +248°F (-20°C to +120°C)

ABVE

ABVE series
▪ Nitrogen capacities from 1.06 to 13.21 gallons (4 to 50 litres)
▪ Maximum pressure 4786 psi (330 bar) depending on model
▪ Extreme operating temperatures: -4°F to +176°F (-20°C to +80°C)

APL
APL series
▪ Nitrogen capacities from 0.04 to 1.06 gallons (0.16 to 4 litres)
▪ Maximum pressure 3626 psi (250 bar) depending on model
▪ Extreme operating temperatures: -4°F to +176°F (-20°C to +80°C)
4 Operating principle, functions and characteristics

OPERATING PRINCIPLE ► A simple principle


► Energy storage If the very low compressibility of fluids makes it difficult to store their
energy in small volumes, it does, however, enable them to transfer a
A hydro-pneumatic accumulator is a vessel which, in hydraulic circuits, is significant force. Gas on the other hand is highly compressible, and can
capable of storing a large amount of energy in a small volume. therefore store considerable amounts of energy in small volumes. The
hydropneumatic accumulator makes use of these two properties.

 The hydropneumatic accumulator is a tank divided into two Gas

chambers by a flexible separator. One chamber is for fluid under


pressure, the other for nitrogen gas.
Oil

 It is pre-charged with nitrogen to a pressure P0. P0 V0

 When a fluid travels through the accumulator, and the pressure P0 V0

P1 of that fluid is higher than the pre-charge pressure P0 of the P1 V1 P2 V2


accumulator, then the gas compresses to P1, the separator changes
shape, and the accumulator can take in the corresponding volume of
fluid.

 Any pressure drop in the hydraulic circuit causes the accumulator P1 V1 P0 V0


to return fluid to the circuit, until pressure reverts to the initial P0.

FUNCTIONS
► Surge control
The accumulator takes in the cinetic energy produced by a moving
column of fluid when the circuit is suddenly shut off (valve, solenoid etc.),
or more generally, when there is a sudden change in circuit pressure.
► Th ermal expansion
The increase in volume due to increased temperature will be absorbed
by the LEDUC accumulator.
► Shock absorbing-suspension
LEDUC accumulators, in a shock absorbing function, reduce fatigue of
hydraulic and mechanical components.
Examples: lifts, forklift trucks, agricultural machinery, construction
equipment, etc.

► Energy recovery and restitution


The energy supplied by a given load can be absorbed by the
accumulator and put back into a hydraulic cylinder to produce a
mechanical movement.
Example: closing railcar hopper doors.
► Leak compensation
A leak in a hydraulic circuit can lead to pressure drop. The LEDUC
accumulator compensates the loss in volume and thus maintains circuit
pressure virtually constant.
Operating principle, functions and characteristics 5

► Pulsation dampening
Adding a LEDUC accumulator to a hydraulic circuit smooths out any
flow irregularities from the pumps. This leads to better operation of the
system, protection of the components and thus increased service life,
and reduced noise levels.
Example: dosing pumps.

► Transfer of fluid
The LEDUC accumulator makes it possible to transfer hydraulic
pressure between two incompatible fluids, via the diaphragm which
separates the two fluids.
Examples:
ƒƒ transfer between hydraulic fluid and sea water,
ƒƒ test bench, etc.
► Energy storage
In a circuit under pressure, the LEDUC accumulators mean a reserve of
fluid may be kept permanently available. Thus a large amount of energy,
accumulated by a low power system during periods of low or no usage,
can be used in a very short time and within one cycle.
Examples:
ƒƒ automatic machines,
ƒƒ braking or declutching of vehicles or construction equipment,
ƒƒ emergency completion of working cycle in case of failure of main
power source.

CHARACTERISTICS

Main Diaphragm Bladder Bladder-diaphragm Piston


characteristics
Without limit
Volumetric ratio
0.75 0.75 0.75 except to reach
(capacity to store a volume)
service pressure

For higher volumetric ratio,


Mounting position Vertical position Vertical position Any positions
vertical position preferred

Capacity for total discharge Yes No, except particular conditions Yes, in particular conditions Yes

Flow control No No No Yes

Control of the Yes


No Reduced No
presence of fluid (indicator possible)

Suitable
Use with special fluids Limited Limited Limited
(special seals)

Service life Good Good Good Very good

Resistance to contaminations Good Good Good Low

Response time Good Medium Good Low

Maintenance interval Short Short Short Long


6 ACS(L) Welded cylindrical accumulators

► Technical description

The ACS(L) type welded accumulators are made up of a shell in high


ACS 4786 psi (330 bar)
Maximum pressure: 4786 (330 bar)
resistance steel containing a fluid-gas bladder-diaphragm. This bladder- Extreme operating temperature:
diaphragm is made of nitrile for the standard ACS range, and of hydro-
ƒƒ Standard version: -4°F to 212°F (-20°C to +100°C)
genated nitrile for low temperature applications. The bladder-diaphragm
is fitted with an anti-extrusion stud, thus allowing rapid and ƒƒ Low temperature version: -40°F to 212°F (-40°C to +100°C)
total discharge of the accumulator.
► Advantages ACSL 3045 or 3626 psi (210 or 250 bar)
Maximum pressure: 3045 or 3626 psi (210 or 250 bar)
ƒƒ Low temperature versions suitable for operation at temperatures depending on the version.
down to -40°F. Extreme operating temperature:
ƒƒ Completely modular from 0.18 to 1.06 gallons (0.7 to 4 litres). ƒƒ Standard version: -4°F to 212°F (-20°C to +100°C)
This design concept means easy addition of intermediate models
ƒƒ Low temperature version:-40°F to 212°F (-40°C to +100°C)
if required.
ƒƒ The bladder-diaphragm offers exceptionally good resistance to ► Deformation of the bladder-diaphragm
fatigue.
ƒƒ Rapid and total discharge possible due to the anti-extrusion stud
actually fitted onto the bladder-diaphragm.
► Operating fluids

P2 V2
P1 V1
P0 V0
ƒƒ Mineral-based hydraulic fluids.
ƒƒ Other fluids: please ask.

► Examples of applications

En e rg y stor age
► Filling gas

Nitrogen only.

► Volumetric ratio (V0–V2)/V0

The recommended volumetric ratio of this type of accumulator is 0.75.


For example: an ACS 4 accumulator can take in a maximum volume of
0.75 V0 = 0.75 x 4 = 3 litres.
► Tests et certifications

Designed and certified according to the European Directive


Su s pension 2014/68/UE. Other certifications on request.
ACS(L) Characteristics and dimensions 7

(1)
M28 x 1 5

ACS(L) series
7 87 (200)
Charging screw or valve
0 53 (13 5)

Ø 4 25 (108) (ACSL)
Ø 4 5 (114 3) (ACS)

Bladder diaphragm
A

Anti-extrusion stud

(2)
B
Ø 1 46 (37) (ACSL)
Ø 2 20 (56) (ACS)

(1) Dimensions for setting up the charging and gauging device


(2) Hydraulic connections - see order code system code 4 (next page)
4

CHARACTERISTICS AND DIMENSIONS


Volume Max. pressure Weight Length A
gallons (L) psi (bar) lbs (kg) inches (mm)
0.18 (0.7) 8.8 (4) 6.9 (175)
0.29 (1.1) 13 (5.9) 9.2 (236)
ACS
0.40 (1.5) 17.2 (7.8) 12.4 (315)
4786 (330)
0.53 (2) 21.8 (9.9) 15.4 (392)
0.66 (2.5) 25.3 (11.5) 18.2 (463)
1.06 (4) 38.6 (17.5) 27.3 (695)

Volume Max. pressure Masse Length A


gallons (L) psi (bar) lbs (kg) inches (mm)
0.18 (0.7) 6.6 (3) 6.9 (175)
0.26 (1) 9.9 (4.5) 9.5 (241)
ACSL
0.40 (1.5) 13 (5.9) 12.4 (315)
3626 (250)
0.53 (2) 16.8 (7.6) 15.4 (392)
0.66 (2.5) 19.6 (8.9) 18.2 (463)
1.06 (4) 30.6 (13.9) 27.4 (696)
8 ACS(L) Order code system

ACS(L) ... S .. .. . . . To obtain the code of your welded cylindrical accumulator


ACS(L), complete the different parameters from 01 to 08 in the
01 02 03 04 05 06 07 08 table on the left according to the options you require (see table below).

For ACS 0.7 L, or ACS(L) low temperature version 104°F (-40°C), please refer to the tables on page 10. For other accumulators, make your choice
as a function of the possible combinations, using the columns below, and use the code in the far right-hand column.
Accumulator type
ACSL ACS ACSL ACS ACSL ACS ACSL ACS ACSL ACS ACSL
ACS 330 bar ● ● ● ● ● ACS
01
ACSL 250 bar ● ● ● ● ● ● ACSL

Volume (L)
02 0.7 1 1.5 2 2.5 4

Operating temperature
03 -20 +100°C ACSL ACS ACSL ACS ACSL ACS ACSL ACS ACSL ACS ACSL S

Fluid side connections


ACSL ACS ACSL ACS ACSL ACS ACSL ACS ACSL ACS ACSL

G3/8" G1

G1/2" ● ● ● ● ● ● ● ● ● ● G2

G3/4" ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● G3
04
M16 x 1.5 M1

M18 x 1.5 ● ● ● ● ● ● ● ● ● ● ● ● M2

3/4 - 16 UNF ● ● ● ● ● ● ● ● ● ● ● ● ● ● U1

1 1/16" - 12 UN ● ● ● ● ● ● ● U2

Gas side connections


ACSL ACS ACSL ACS ACSL ACS ACSL ACS ACSL ACS ACSL

Charging screw
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● V
M28 x 1.5
05 P1620 valve
● ● ● ● ● ● ● ● ● ● ● ● ● W
(M16x200)

SCHRADER valve
● ● ● ● Y
(8V1)

Gas side connections protection


ACSL ACS ACSL ACS ACSL ACS ACSL ACS ACSL ACS ACSL

Without protection
(P1620, SCHRADER)
06 ● ● ● ● ● ● ● ● ● ● ● N
Plastic plug
(Screw M28 x1.5)

With metallic plug ● ● ● ● ● ● ● ● ● ● ● P

Fluid side options


ACSL ACS ACSL ACS ACSL ACS ACSL ACS ACSL ACS ACSL

Without connection ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● N
Male connection
● ● ● ● ● ● ● M
M33 x 1.5 - G1/2"

07 Male connection
● ● ● ● ● ● ● D
M18 x 1.5
Male connection
● ● ● ● ● ● ● E
M27 x 2
Male connection
● ● ● ● ● ● ● J
G3/8’’

Charging pressure
08 Specify the charging pressure (in bar)
ACS(L) Fluid and gas connections 9

► Hydraulic connections - Code 04

Code

ACS(L) series
Implantation following ISO 1179 Implantation
Implantation Øfollowing
B SAEISO
following J5141179 Implantation following SAE J514
ISO 9974 04 ISO 9974 Code
ØB
04
G1 G3/8’’
U1 3/4-16UNF - 2B
G2 G1/2’’
U2 1’’1/16 - 12UNF - 2B
B G3 G3/4’’ B B B
B see order code system code 4
M1
B seeBorder
M
see order16 x 1,5
code
code systemsystem
code 4code 4 B see order code system code 4

M2 M 18 x 1,5

►Gas side connections - Code 05

V W Y

M28 x 1 5
1 42 (36)

Ø 0 78 (20)
0 77 (19 6)

M8
0 53 (13 5)

0 53 (13 5)
0 53 (13 5)

►Gas side protections - Code 06

36 on flats
M28 x 1 5
36 on flats
N P P P
36 on flats

Ø 0 78 (20)
36 on flats

M28x1 5
36 on flats
M28 x 1 5
36 on flats

M28 x 1 5
1 41 (36)
2 36 (60)

M8
0 77 (19 6)

M8
1 73 (44)
0 53 (13 5)
0 94 (24)

0 53 (13 5)
0 53 (13 5)
0 53 (13 5)

►Hydraulic options - Code 07

N M D E J
ØB ØB ØB
C3 on flats

C3 on flats
C3 on flats

C2
C2

ØB
C2
C1
0 63 (16)

C1
C1

ØC ØC
ØD
ØC Ø C Male, for implantation following ISO 6149 Ø C Male, for implantation following ISO 1179 (Form E)

Code
ØB ØC C1 C2 C3 D
07

Code
N - - - - -
04
M G1/2’’ M33 x 1.5 0.78 (20) 0.47 (12) 1.61 (41) G1/2’’
D G1/2’’ M18 x 1.5 0.49 (12.5) 0.61 (15.5) 1.06 (27) -
E G1/2’’ M27 x 2 0.55 (14) 0.63 (16) 1.26 (32) -
J G1/2’’ G3/8’’ 0.47 (12) 0.61 (15.5) 1.06 (27) -
10 ACS and ACSL Low temperature version -40°F

► ACS low temperature version models

Nitrogen Weight Hydraulic


LEDUC Max. pressure Length A
capacity V0 connection Gas side
code psi (bar) lbs (kg) inches (mm)
gallons (litres) ØB
ACS 0.7 0610415 0.18 (0.7) 4786 (330) 9 (4) 6.89 (175) G1/2" screw
ACS 1.5 0610425 0.40 (1.5) 4786 (330) 17.2 (7.8) 12.40 (315) G3/4" screw
ACS 2 0610430 0.53 (2) 4786 (330) 21.8 (9.9) 15.43 (392) G3/4" screw
ACS 2.5 0610435 0.66 (2.5) 4786 (330) 25.3 (11.5) 18.22 (463) G3/4" screw
ACS 4 0610440 1.06 (4) 4786 (330) 36.6 (17.5) 27.36 (695) G3/4" screw

► ACSL low temperature version models

Nitrogen Weight Hydraulic


LEDUC Max. pressure Length A
capacity V0 connection Gas side
code psi (bar) lbs (kg) inches (mm)
gallons (litres) ØB
ACSL 0.7 068360 0.18 (0.7) 3045 (210) 6.6 (3) 6.89 (175) G1/2" screw
0610210 0.26 (0.99) 3045 (210) 9.9 (4.5) 9.48 (241) G1/2" screw
G1/2" / M33 x 1.5
ACSL 1 0610335 0.26 (0.99) 3045 (210) 9.9 (4.5) 9.48 (241) screw
MALE
068355 0.26 (0.99) 3045 (210) 9.9 (4.5) 9.48 (241) G3/4" screw
ACSL 1.5 068350 0.40 (1.5) 3045 (210) 13 (5.9) 12.40 (315) G3/4" screw
ACSL 2 068345 0.53 (2) 3045 (210) 16.7 (7.6) 15.43 (392) G3/4" screw
ACSL 2.5 068265 0.66 (2.5) 3045 (210) 19.6 (8.9) 18.22 (463) G3/4" screw

The ACS(L) low temperature models accumulators are equiped with a hydrogenated nitrile diaphragm (ref. E/7).

ACS 0.7 L model, not in the code system

► ACS 0.7

Nitrogen Weight Hydraulic


LEDUC Max. pressure Length A
capacity V0 connection Gas side
code psi (bar) lbs (kg) inches (mm)
gallons (litres) ØB
065947 0.18 (0.7) 4786 (330) 9 (4) 6.89 (175) 3/4-16UNF-2B SCHRADER valve
065950 0.18 (0.7) 4786 (330) 9 (4) 6.89 (175) M16 x 1.5 screw
065952 0.18 (0.7) 4786 (330) 9 (4) 6.89 (175) M18 x 1.5 screw
065975 0.18 (0.7) 4786 (330) 9 (4) 6.89 (175) G3/8" P1620 valve
066035 0.18 (0.7) 4786 (330) 9 (4) 6.89 (175) G3/4" screw
066130 0.18 (0.7) 4786 (330) 9 (4) 6.89 (175) G1/2" screw
066445 0.18 (0.7) 4786 (330) 9 (4) 6.89 (175) G3/8" screw

066695 0.18 (0.7) 4786 (330) 9 (4) 6.89 (175) G1/2" / M33 x 1.5 MALE screw
ACS(L) Accessories 11

5 47 (139)

AC C ES S O R I E S 3 42 (87)

Série ACS(L)
1 57 (40)

0 35 (9)
► ACS(L) adjustable clamps  1 38 (35) 0 95 (24)
00 0 51 (13)
6( 3 54 (90)
1,5
Volume Code )
Caracteristics Ø4 25 to 4 67
(L) LEDUC

M8
(108 to Ø 118 5)
Zinc-plated steel 254021

2 87 (73)
0.7 - 1 - 1.5 Zinc-plated steel

0 12 (3)
254031
2 - 2.5 - 4 quick-tightening
Stainless steel 254032 6 30 (160)

0 79 (20)
► ACS(L) fixed clamp 
Ø 4 53 (115)
Volume Code
Caracteristics
(L) LEDUC
0.7 - 1 - 1.5 Zinc-plated steel C001028

3 54 (90)
1 77 (45)
Tightening torque of the fixation screws: 20 Nm.

M8 M8
5 (127)

►ACS(L) clamps 

Ø0
Volume Code 31
Caracteristics (8 Ø 4 53 (115)
(L) LEDUC )
0.7 - 1 - 1.5 Zinc-plated steel C001031
2 - 2.5 - 4 Stainless steel C001032

Tightening torque of the fixation screws: 20 Nm.

2 95 (75)
1 97 (50)
M8
4 84 (123)
12 AS Spherical accumulators

► Technical description

LEDUC spherical accumulators consist of two hemispherical shells


AS 5800 psi (400 bar)
Maximum pressure: 5800 psi (400 bar)
which are screwed together and which hold a diaphragm. This Extreme operating temperature:
diaphragm has a metal stud which closes off the operation hole when
the fluid is completely discharged. There is therefore no danger of ƒƒ Standard version : -4°F to + 212°F (-20°C to + 100°C)
damage to the diaphragm. Low temperature version: -40°F to + 212°F (-40°C to + 100°C)
The gas side port is fitted with a charging valve allowing the pressure in
the accumulator to be checked or changed.
Separator: ► Deformation of the diaphragm
ƒƒ Standard, Nitrile: from -4°F to + 212°F (-20°C to +100°C)
ƒƒ Special: from -40°F to + 212°F (-40°C to +100°C) dynamic use.
► Advantages P0 V0

The diaphragm only changes position, the elastomer in fact works little.
The LEDUC spherical accumulator owes most of its qualities to its
diaphragm and metal pin:
ƒƒ excellent gas/fluid tightness,
ƒƒ possibility of total and rapid discharge, P1 V1 P2 V2
ƒƒ can be adapted to suit a wide range of fluids hanged.
► Operating fluids

ƒƒ Mineral-based hydraulic fluids: standard diaphragm.


ƒƒ Corrosive or non-standard fluids: please consult our Customer ► Filling gas
Service Department.
Nitrogen only.
► Examples of applications
► Volumetric ratio(V0–V2)/V0
Pu l s ati ons dam penin g The volumetric ratio of this type of accumulator is 0.75.
For example: an AS 1 accumulator can take in a maximum volume of 0.75 V0:
0.75 V0 = 0.75 x 1.1 = 0.82 litres.

► Protection
On request, ARCOR® anti-corrosion treatment or paint.
► Tests and certifications

Designed and certified according to the European Directive


2014/68/UE. Other certifications on request.

► After-sales service
HYDRO LEDUC provides after sales service, supplies spare parts and can
requalify your accumulators (retesting), only for the accumulators operated in
Tra n sfer France.
AS Characteristics, dimensions and accessories 13

CH A R A C T ER I S T IC S A N D D IME N SIONS

Charging valve

ØC
A

Diaphragm
D
E
B

ØF

AS series
Anti-extrusion stud

ØH
K

ØG

1 26 (32) on flats

Charging valve
1 42 (36)

0 40 (10)
4 41 (112)

Nitrogen Dimensions
Max.
LEDUC capacity Weight inches (mm)
AS pressure
code Vo gallons lbs (kg)
psi (bar) A B ØC D E ØF ØG ØH K
(litres)
ØC
AS 00 20 060932 0.05 (0.19) 5801 (400) 3 (1.2) 5.91 (150) 2.72 (69) 3.33 (84.5) 0.35 (9) 0.79 (20) 3.29 (83.5) 1.14 (29) G1/4" 0.47 (12)
0 47 (12)

0 39 (10)

AS 00 50 060972 0.12 (0.45) 5801 (400) 6 (2.8) 7.24 (184) 3.50 (89) 4.49 (114) 0.47 (12) 0.91 (23) 4.43 (113) 1.57 (40) G3/8" 0.36 (16)
A

AS 00 70 060782 0.17 (0.65) 3626 (250) 7 (3) 7.76 (197) 3.50 (89) 4.70 (119.5) 0.35 (9) 0.94 (24) 4.67 (119) 1.18 (30) G3/8" 0.51 (13)
G1/4" Diaphragm
D

AS 01 00 060110 0.29 (1.1) 5801 (400) 12 (5.5) 7.76 (197) 4.41 (112) 6.44 (163.5) 1.99 (50.5) 1.99 (50.5) 6.44 (164) 1.57 (40) M18 x 1.5 0.47 (12)
1 42 (36) on flats
E

AS 02 50 060812 0.66
Ø 1(2.55)
64 (41 8) 5801 (400) 31 (14) 9.88 (251) 6.34 (161) 8.41 (213.5) 1.46 (37) 1.14 (29) 8.27 (210) 2.01 (51) G3/4" 0.67 (17)
B

AS 04 00 060121 1.07 (4.1) 5801 (400) 49 (22) 11.73 (298) 7.95 (202) 9.88 (251) 1.73 (44) 1.57 (40) 9.72 (247) 4.13 (105) M33 x 2 0.79 (20)
AS 10 00 060141 2.65 (10.19) 5801 (400) 117 (53) 15.39 (391) 10.55 (268) 13.35 (339) Ø F 2.07 (52.5) 2.07 (52.5) 13.11 (333) 4.14 (105.1) M33 x 2 0.79 (20)

Anti-extrusion stud
AC 00 02 060955 0.004 (0.017) 5801 (400) 1 (0.640) see drawing
ØH
K

HYDRO LEDUC provides after sales service, supplies spare parts and can requalify your accumulators (retesting).
ØG

1 26 (32) on flats
1 42 (36)

0 40 (10)
4 41 (112)
0 47 (12)

0 39 (10)

G1/4"
1 42 (36) on flats
Ø 1 64 (41 8)
14 AS Spherical accumulators

To obtain the code of your welded cylindrical accumulator


AS/AC AS or AC, complete the different parameters from 01 to 06
in the table on the left according to the options you require
01 02 03 04 05 06
(see table below).

Make your choice as a function of the possible combinations, using the columns below, and use the code in the far right-hand column.

Accumulator type

01 Spherical accumulator ● ● ● ● ● ● ● AS
Compact accumulator ● AC

Nominal size (L)

02 0,02 0,2 0,5 0,7 1 2,5 4 10

Shell protection
Without protection ● ● ● ● ● ● ● ● N
03
ARCOR® treatment ○ ○ ○ ○ ○ ○ ○ ○ P

Diaphragm material
NBR ● ● ● ● ● ● E1
End stop adherized ● ○ ○ ● ○ ○ ○ ○ E1A
Stainless steel end stop ○ ○ ○ ○ ○ ○ E2
04
ECO (epichlorohydrin) ○ ○ E3
EPDM (epr) ○ ○ ○ ○ ○ E4
FKM (Viton®) ○ ○ ○ ○ ○ ○ E5

Charging valve
P1620 valve (M16x200) ● ● ● ● ● ● ● ● W
P1620 stainless steel valve
05 (M16x200) ○ ○ ○ ○ ○ ○ ○ ○ X

SCHRADER valve (8V1) ○ ○ ○ ○ ○ ○ ○ ○ Y

Gas charging pressure


06 Specify the charging pressure (in bar)

● Standard version
○ Special version on request.
15

AC C ES S O R I E S

► Fixation clamps   00 3 54 (90)


6(
15
)
Volume Code Ø 4 25 to 4 67
Characteritics

M8
(108 to 118 5)
(L) LEDUC
Zinc-plated steel 254021

2 97 (73)

0 12 (3)
Zinc-plated steel
0.13 (0.5) - 0.17 (0.7) 254031
quick tightening
Stainless steel 254032 6 30 (160)

► Fixation clamps 

AS series
Dimensions M12 x 65 8 8

1 18 (30)
Volume LEDUC 0 94 (24)
inches (mm) Characteristics 0 51 (13) ØD
gallons (Liters) code
ØD L1 L2
0.26 (1) 6.61 (168) 7.24 (184) 5.83 (148) Zinc-plated steel 254022

0 33 (8 5)
0.66 (2.5) 8.27 (210) 10 (254) 8.35 (212) Zinc-plated steel 254006
1.06 (4) 9.72 (247) 11.81 (300) 9.76 (248) Zinc-plated steel 254005
L1

Dimensions in inches (mm)


16 ABVE Bladder accumulators

► Technical description
The ABVE bottle type acccumulators consist of:
ABVE 4786 psi (330 bar)
ƒƒ a forged steel body, Maximum pressure: 4786 (330 bar)
ƒƒ a bladder, ABVE 4 maximum pressure: 5076 (350 bar)
ƒƒ a charging valve,
Extreme operating temperature:
ƒƒ an oil side orifice fitted with a poppet valve which prevents extru-
sion of the bladder, and an air bleed screw used during system ƒƒ Standard version: -4°F to +176°F (-20°C to +80°C)
start-up.
► Advantages
► Deformation of the bladder
Bladder accumulator component parts are interchangeable with those of
major accumulators available.
Dimensions allow for easy installation and also use in batteries.
P0V0 P1V1 P2V2
► Operating fluids

ƒƒ Mineral-based hydraulic fluids: standard bladder.


ƒƒ Non-standard and/or corrosive fluids: please consult our Cus-
tomer Service Department.

► Examples of applications

E nergy stora ge

► Filling gas

Nitrogen only.

► Volumetric ratio (V0–V2)/V0


The volumetric ratio of this type of accumulator is 0.75.
For example, an ABVE 4 accumulator can take in a maximum volume of : 0.75
V0 = 0.75 x 3.7 = 2.8 Litres.
► Tests et certifications

Designed and certified according to the European Directive


2014/68/UE. Other certifications on request.
HYDRO LEDUC tests its ABVE accumulators for 2 000 000
cycles with a ∆P = 4351 psi (300 bar).

► After-sales service
HYDRO LEDUC provides after sales service, supplies spare parts and can
requalify your accumulators (retesting) only for the accumulators operated in
France.
ABVE Characteristics, dimensions and accessories 17

CH A R A C T ER IS T IC S A N D D IME N SIONS

Charging valve

Bladder

ABVE - - G4-N ABVE - - G5-N


A

ØC Poppet 
valve

bleed screw M5x80 bleed screw M12x100

ØD 48
B ØE
39 5
Bleed screw
G1"1/4 G2"
(Dimensions in mm)
ØF 

ABVE series
Nitrogen Dimensions
Max.
capacity Weight inches (mm)
ABVE pressure
Vo gal lbs (kg)
psi (bar) A B ØC ØD ØE ØF G
(litres)
ABVE 4 0.96 (3.7) 5076 (350) 28.66 (13) (417.4) 141.09 (64) 370.38 (168) 149.91 (68) 116.84 (53) G1 1/4" 144.18 (65.4)
ABVE 10 2.54 (9.6) 5076 (350) 71.65 (32.5) (575.4) 224.87 (102) 491.63 (223) 222.67 (101) 167.55 (76) G2" 144.18 (65.4)
ABVE 20 4.65 (17.6) 5076 (350) 99.20 (45) (878.4) 224.87 (102) 491.63 (223) 222.67 (101) 167.55 (76) G2" 144.18 (65.4)
ABVE 32 8.64 (32.7) 5076 (350) 176.37 (80) (1403.4) 224.87 (102) 491.63 (223) 222.67 (101) 167.55 (76) G2" 144.18 (65.4)
ABVE 50 12.92 (48.9) 5076 (350) 246.90 (110) (1926) 224.87 (102) 491.63 (223) 222.67 (101) 167.55 (76) G2" 144.18 (65.4)
18 ABVE Bladder accumulators

ABVE To obtain the code of your welded cylindrical accumulator ABVE, complete
the different parameters from 01 to 07 in the table on the left according to
01 02 03 04 05 06 07 the options you require (see table below).

Make your choice as a function of the possible combinations, using the columns below, and use the code in the far right-hand column.

Accumulateur type
01 ABVE ● ● ● ● ● ABVE

Volume (L)
02 04 10 20 32 50

Gas side diameter


Ø 22 mm ● ● ● ● ● S2

Ø 50 mm ● S1

Oil side connections


G1 1/4" ● G4

G2" ● ● ● ● G5

Gas side connections


P1620 valve (M16x200) ● ● ● ● ● W

V15 valve (5/8"UNF) ● ● ● ● ● T

Oil side options


Without option ● ● ● ● ● N
G3/4" ● ● ● ● ● A

G2"G1" ● ● ● ● B

G2"full ● ● ● ● C

Charging pressure
07 Specify the charging pressure (in bar)

Flanged connection on request.


19

AC C E S S O R I E S

1 18 (30)
0 35 (9)
► Fixation clamps

30
 0 51 L2 13 L2

9
(13)
M12x65 0 35 (8 8)

1 18 (30)
ØD ØD
1 36 (34 5) 1 36 (34 5)
Volume Dimensions (mm) M12x65 0 35 (8 8) M12x65
Characteristics Code
(L) ØD L1 L2 0 35 (8 8)

0 33 (8 5)
4 6.61 (168) 7.24 (184) 5.83 (148) 254022

0 33 (8 5)
10 - 20 Zinc-plated steel L1
8.70 (221) 10.16 (258) 8.50 (216) 254007 L1
32 - 50
254022 254007

► Fixation seats  
59)
Volume Code 26 (1

0 98 (25)
3 15 (80)
25 (1
08) Ø6
Ø4

(L) LEDUC

25

1 57 (40)
2x
4 254012 Ø 0 67 (17)
63
0 5)
8 2 (160 (17 4x 35)
7 (2 ) 6 89 7
10 87 (2 5 (2
92
10 - 20 - 32 - 50 254008 10) Ø0 67 (17) 24 00
(26 )
0)

254012 254008

► Adaptors 

Volume Dimensions Code
Characteristics A
(L) A B C (mm) LEDUC
G3/4" 0.63 (16) 066305
4 G1 1/4"
Full 0.63 (16) 066307 C

ABVE series
G3/4" 0.51 (13) Steel 066074
B
10 - 20 - 32 - 50 G2" G1" 0.75 (19) 066068
Full 0.75 (19) 066069

Dimensions in inches (mm).


20 APL Piston accumulators

► Technical description
APL accumulators are designed with a high mechanical resistance
APL 5076 psi (350 bar)
Maximum pressure: 5076 (350 bar)
forged steel body. Extreme operating temperature:
The fluid-gas separating piston is equipped with seals adapted to:
ƒƒ Standard version: -4°F to 176°F (-20°C to + 80°C)
ƒƒ the fluids to convey,
ƒƒ For other temperatures, please consult us.
ƒƒ the operating temperature,
The APL accumulators can be fitted with a charging screw or charging
valve, and are a modern solution for the needs of hydraulic circuits.
APL 3626 psi (250 bar)
Maximum pressure: 3626 (250 bar)
► Advantages Extreme operating temperature:
ƒƒ Standard version: -4°F to 176°F (-20°C to + 80°C)
LEDUC APL piston accumulators, are designed: ƒƒ For other temperatures, please consult us.
ƒƒ to withstand very high volumetric ratios,
ƒƒ to ensure total and rapid discharge of fluid,
ƒƒ for assembly in any position,
ƒƒ to guarantee minimal nitrogen loss overtime,
ƒƒ for easy adaptation for use with different fluids and tempera- ► Movement of the piston
tures.
► Operating fluids

ƒƒ Mineral-based hydraulic fluids.

P1V1

P2V2
P0V0
ƒƒ Non-standard and/or corrosive fluids: please consult our
Customer Service Department.

► Example of applications
E nergy stora ge

► Filling gas

Nitrogen only.

► Charging
Two versions available:
ƒƒ with charging screw,
ƒƒ with charging valve.
► Tests and certifications

Designed and certified according to the European Directive


2014/68/UE. Other certifications on request.
APL Characteristics and dimensions 21

M28 x 1,5
Charging screw
or charging valve (1)
0 53 (13 5)

Ø 3 72 (94 6)

Ø 3 74 (95)

Piston
A

Ø (2)
Ø 1 46 (37)

(1) See order code system code 06 (next page)


(2) Hydraulic connections - see order code system code 05 (next page)

CHARACTERISTICS AND DIMENSIONS


Volume Max. pressure A ØD ØC Weight
gallons (L) psi (bar) (mm) (mm) (mm) (kg)
0.04 (0.16) 5.89 (149.5) 5.29 (2.4)
0.08.(0.32) 9.09 (231) 7.05 (3.2)
0.13 (0.5) 12.72 (323) 9.04 (4.1)
AP
0.20 (0.75) 17.72 (450) 13.45 (6.1)
5076 (350) 2.52 (64) 2.50 (63.5)
0.26 (1) 22.72 (577) 16.76 (7.6)
0.33 (1.25) 27.76 (705) 21.16 (9.6)
0.40 (1.5) 32.76 (832) 23.37 (10.6)
0.48 (1.8) 38.78 (985) 27.34 (12.4) APL series

Volume Max. pressure A ØD ØC Weight


gallons (L) psi (bar) (mm) (mm) (mm) (kg)
0.13 (0.5) 7.95 (202.3) 13.67 (6.2)
0.20 (0.75) 9.93 (252.1) 15.43 (7)
0.26 (1) 11.89 (301.8) 17.42 (7.9)

APL 0.40 (1.5) 15.80 (401.3) 20.84 (9.5)


0.53 (2) 3626 (250) 19.72 (500.8) 3.74 (95) 3.72 (94.6) 24.47 (11.1)
0.66 (2.5) 23.63 (600.2) 28.22 (12.8)
0.79 (3) 27.55 (699.7) 31.75 (14.4)
0.82 (3.5) 31.46 (799.2) 35.27 (16)
1.06 (4) 35.38 (898.6) 38.80 (17.6)

Dimensions in inches (mm).


22 APL Order code system

AP(L) To obtain the code of your piston accumulator AP(L), complete


the different parameters from 01 to 08 in the table on the left
01 02 03 04 05 06 07 08 according to the options you require (see table below).

Make your choice as a function of the possible combinations, using the columns below, and use the code in the far right-hand column.

Accumulator type
AP 350 bar ● ● ● - - ● ● - ● ● - ● - - - - - AP
01
APL 250 bar - - - ● ● - ● - ● - ● ● ● ● ● APL

Volume (L)
02 0,16 0,32 0,5 0,7 0,75 1 1,25 1,5 1,8 2 2,5 3 3,5 4

Type of seal
03 Double sealing ● ● ● ● ● ● ● ● ● ● ● ● ● ● D

Piston diameter
Ø 50 mm ● ● ● - - ● ● - ● ● - ● - - - - - 06
04
Ø 80 mm - - - ● ● - - ● - - ● - ● ● ● ● ● 08

Fluid side connection


G1/2” ● ● ● - - ● ● - ● ● - ● - - - - - G2
G3/4” - - - ● ● - - ● - - ● - ● ● ● ● ● G3

05 9/16 - 18 UNF ● ● ● ● ● ● ● ● U0
3/4 - 16 UNF ● ● ● - - ● ● - ● ● - ● - - - - - U1
1"1/16 - 12 UNF - - - ● ● - - ● - - ● - ● ● ● ● ● U2

Gas side connection


M28 x 1.5 screw ● ● ● ● ● ● ● ● ● ● ● ● ● ● V
06
P1620 ● ● ● ● ● ● ● ● ● ● ● ● ● ● W

Gas side options


Without
● ● ● ● ● ● ● ● ● ● ● ● ● ● N
protection
07 With metallic
plug ● ● ● ● ● ● ● ● ● ● ● ● ● ● P

Fluid side options


08 Without
● ● ● ● ● ● ● ● ● ● ● ● ● ● N
protection

Charging pressure
09 Specify the charging pressure (in bar)
APL Connections and accessories 23

► Hydraulic connections - Code 05

Code Code
Implantation following ISO 1179 ØImplantation
B SAE J514
Implantation following following ISO 1179 Implantation following SAE J514 ØB
05 05
G2 G1/2’’ U0 9/16 - 18 UNF- 2B
G3 G3/4’’ U1 3/4-16UNF - 2B

B B B B U2 1’’1/16 - 12UNF - 2B

B see order code system code 5 B see order B see


code ordercode
system code5system code 5 B see order code system code 5

► Gas side connexion - Code 06 ► Gas side connexion - Code 07

V W N P P

36 on flats
M28X1 5

36 on flats
Ø 0 78 (20)
1 42 (36)

M28X1 5 M28X1 5
M8 M8

1 62 (36)
2 36 (60)
M8
0 53 (13 5)

0 53 (13 5)

0 94 (24)
0 53 (13 5)

0 53 (13 5)
0 53 (13 5)
M28x1 5

AC C E S S O R I E S F O R A P L

► Adjustable clamps 
 0 98 (25)
0 51 (13)
Volume Dimensions inches (mm)
Model Characteristics Code
gallons (L) A B C D E F G
Ø3.74 Zinc-plated steel C001026
to
Zinc-plated steel
3.74 C001033
0.13 to 1.06 2.60 6.30 3.54 3.42 1.38 1.57 quick tightening
APL
(0.5 to 4) (66) (160) (90) (87) (35) (40) 00
Ø95 6(
15
D
to Stainless steel C001027 ØA
)
E
100 M8

0 35 (9)
G
Ø2.36
B F
to
2.76 1.59 4.72 2.76 3.35 0.75 1.97 C
AP 0.16 to 1.8 Zinc-plated steel C002160 0 12 (3)
(40.5) (120) (70) (85) (19) (50)
Ø60
to 70
APL series

► Fixed clamps  

Volume Dimensions inches (mm)


Model Characteristics Code 0 79 (20)
gallons (L) A B C D E
00
0.13 to 1.06 3.94 4.41 2.76 2.17 1.37 Zinc-plated steel C001029 8(
2)
ØA
APL
(0.5 to 4) (100) (112) (70) (55) (35) Stainless steel C001030
0.04 to 0.48 2.56 3.03 1.97 1.97 0.79
E

AP Zinc-plated steel C002163


(0.16 to 1.8) (65) (77) (50) (50) (20) M8
D C
B
Tightening torque of the fixation screws: 14.7 lbf.ft (20 N.m).

Dimensions in inches (mm).


24 Safety blocks

DE SC R I P T I O N CODIFICATION

These safety and shut-off blocks are designed to bring together in To obtain the code of your safety block, complete the different parameters
a single block the necessary safety organs required for the correct from 01 to 06 in the table on the left according to the options you require
operation of hydraulic circuits incorporating accumulators. (see table below).
The basic block consists of: :
ƒƒ a ball valve with quarter turn closure, to isolate the accumulator
BS
from the circuit;
ƒƒ needle valve ensuring the manual decompression of the circuit; 01 02 03 04 05 06
ƒƒ relief valve (directly operated) set at the maximum operating pres-
sure of the accumulator. This relief valve should never be used as Make your choice as a function of the possible combinations, using the
a limiter to protect the hydraulic pump; columns below, and use the code in the far right-hand column.
ƒƒ the Q version is fitted with a one-way adjustable flow limiter.
Mounted on the main block, this limiter controls the accumulator Type
outlet flow, whilst inlet flow remains unrestricted. 01 Safety blocks BS

► General technical characteristics Nominal crossing diameter


DN16 ● ● ● 1
ƒƒ nominal crossing diameter: 0.63 in (16 mm) (BS 1 Block), 02
0.95 in (24 mm) (BS 2 Block); DN24 ● 2
ƒƒ maximum working pressure: 5076 psi (350 bar) ;
ƒƒ Temperature ranges : – 15°C to + 70°C; Decompression control
ƒƒ fluid: mineral based hydraulic oil (for other fluids please contact Without control ● N
03
our Customer Service department); Manual ● ● ● M
ƒƒ flow: see pressure loss graph;
ƒƒ relief valve (nominal diameter): 0.24 in (6 mm) (BS1) Flow limiter
0.40 (10 mm) (BS2); Without limiter ● ● ● N
ƒƒ fitting of the BS2 Safety block, output side: welding-neck flange 04
With limiter ● ● Q
CETOP 5800 psi (400 bar) standard.
ƒƒ Equipped with FKM seals. Safety relief valve setting*
NB : as standard, BS2 is fitted with a 2’’ port (accumulator side). 210 bar ● ● ● ● 210

250 bar ● ● ● ● 250


The safety and shut-off blocks are available in a 05
simplified version. 330 bar ● ● ● ● 330

350 bar ● ● ● ● 350


They consist of a relief valve (directly operated) set at the maximum
operating pressure of the accumulator. This relief valve should never be
used as the limiter to protect the hydraulic pump. Adapter connection
Without flange ● ● N

G3/4ʺ ● ● ● A
06
G1 ¼" ● ● ● B

G2ʺ ● ● ● ● C

*The pressure limiter setting is given for a flow at 13.21 gal/min (50 l/min).

6
Pressure loss (bar)

BS1
5
► Graph of pressure drop
as a function of flow 4
BS2
3

100 200 300 400 500 600


BS1 and BS2 Pressure loss Flow: l/min
Oil viscosity: 30 cSt
Ve r s i o n s a v a i l a b l e 25

D I M EN S I O N S

BS1 - N - N - ...N BS1 - M - N - ... - N 2 02 (51 3)

89 A
A 0 9 (22 5) 3 15 (80)
0 70 3 30 (84)

7 30 (185 5)
M
(17 6)
1 38 (35)

2 83 (72)

2 (51)
T

1 93 (49)
3 15 (80)

0 7 (17)
1 26 (32)
T M

3 30 (84)
P P

G1/4’’ 2 84 (72 2) T
depth 0 47 (12) 1 38 (35) G1/4’’
Ø 1 30 (33) depth 0 10 (2 5)
P G3/4’’ depth 0 63 (16) depth 0 47 (12) 1 38 (35)
G3/4’’ depth 0 63 (16) 2 (50 5)
Ø 1 40 (35 5) depth 0 06 (1 5) 3 03 (77)
P

2 36 (60) 2 36 (60)
1 52 (38 5)
1 32 (33 5)
1 97 (50)

1 31 (33 4)
4xM10x1 5

1 97 (50)
A
depth 0 41 (10 5)

Flanges available for BS1 blocks


3 31 (84) 2 02 (51 3) 3 03 (77)
BS1 - M - Q -...

BS1 - ... - A BS1 - ... - B BS1 - ... - C A

G2’’

1 85 (47)

1 85 (47)
185 5
0 95 (24)

M
0 81 (20 50)
0 61 (15 6)

T
4 72 (120)

G1’’1/4

3 31 (84)
G3/4’’
P
1 97 (50)
1 81 (46)

G1/4’’
depth 0 47 (12)
G3/4’’ depth 0 63 (16)
Ø 1 40 (35 5) depth 0 06 (1 5)
6 34 (161) 3 03 (77)
2 36 (60)

1 32 (33 5)
1 97 (50)
5 48 (139 1)

BS2 - M - N - ... - C BS2 - M - Q - ... - C


4x M12 x 0 08 (2) 2
4x M12 x 0 07 (1 75) 2 depth 0 80 (20) (66 63
(66 63 A P 7)
A depth 0 80 (20) P 7)
2 03 (51 6)
1 89 (48)
2 03 (51 6)

M 4x M14 x 0 08 (2)
1 90 (48)

depth 0 80 (20) M
T 4x M14 x 0 08 (2)
depth 0 80 (20)
(3 24
)
15
1

P
P 2 03 (51 6) 4
2 03 (51 6) 2 2 1 5)
(3
4 57 (116)
2 11 (53 5) 3 78 (96)
3 78 (96) G2’’
4 57 (116)
0 98 (25)

G2’’ A
3 78 (96) A
0 98 (25)

1 38 (35)
1 38 (35)

2 70 (68 5)
8 70 (221)

1 18 (30) 8 86 (225)
0 98 (25)
1 77 (45)

2 64 (67)

M
4 57 (116)

1 30 (33)
4 57 (116)

M
T 2 70
(68 5)

G3/8’’ T
depth 0 51 (13) 1 46 (37) G3/8’’
2 46 (62 5) depth 0 51 (13)
3 78 (96) 3 78 (96) 3 78 (96)

3 78 (96) 3 78 (96)
2 83 (72) 2 83 (72)
3 78 (96)
2 83 (72)
1 89 (48)
1 90 (48)

A A
3 78 (96)
2 83 (72)

Dimensions in inches (mm).


26 Pressure relief valves

DBDS cartridges
The pressure relief valve integrated in BS1 and BS2 safety blocks (see
pages 24 and 25) are designed to limit the maximum pressure of the
circuit to ensure it cannot exceed the maximum rated pressure of the
accumulator.

► General technical characteristics

LEDUC Pressure range* Tightening torque Weight


Type Reference Ø D11
code psi (bar) (N.m) lbs (kg)

C001997 3046 (210)


C001998 3626 (250)

Size 6 DBDS 6 C001999 4786 (330) M 28 x 1.5 80 0.88 (0.4)


C002000 5076 (350)

C002001 5800 (400)

C002003 3046 (210)

C002004 3626 (250)

Size 10 DBDS 10 C002005 4786 (330) M 35 x 1.5 140 1.10 (0.5)

C002006 5076 (350)

C002007 5800 (400)

*The pressure limiter setting is given for a flow at 13.21 gal/min (50 l/min).

Hydraulic fluid Mineral hydraulic oil


Required fluid cleanliness class ISO 4406 class 20/18/15
Nominal fluid viscosity 37 mm2/s at 131 °F (55°C)
Viscosity range De 2.8 at 380 Cst

Fluid temperature range Recommended: from 104 to 131 °F (40 to 55°C)


(in tank) Maxi: from -4 to 158 °F (-20°C +70°C)
Ambient temperature range From -4 to 158 °F (-20°C +70°C)
DBDS 6 DBDS 10
Max. operating pressure
5800 psi (400 bar) 9137 (630 bar)
Max. pressure in T port 43 psi (3 bar)

S4 S3 S2 S1
Ø D11
Ø D1
Ø 0 10 (2 5)

L1

► Dimensions

Type S1 S2 S3 S4 L1
0 05 A
01 A

L27
Size 6 1.26 (32) 1.18 (30) 0.75 (19) 0.24 (6) 2.83 (72) Ø D13
Ø D14

Size 10 1.42 (36) 1.18 (30) 0.75 (19) 0.24 (6) 2.68 (68)
T P
α
ØD12H9

These dimensions in inches (mm) are given as an indication.


ØD11

Ø D15

A
90°

1 25
S4 S3 S2 S1

Pressure relief valves 27

Ø D11
Ø D1
Ø 0 10 (2 5)
L1
► Dimensions

0 05 A

01 A
L27
Ø D13

Ø D14
T P
α
ØD12H9
ØD11

Ø D15
A
90°

1 25

T P
L21
L22 Ø D16
L23 0 5-45°
L24
L25
1 25

L28

► Dimensions of the implantation of the DBDS cartridge

Type Ø D11 Ø D12 Ø D13 Ø D14 Ø D15 Ø D16 L21 L22 L23 L24 L25 L27 L28 α

2.22
Size 6 M 28 x 1.5 0.98 (25) 0.24 (6) 0.59 (15) 0.98 (24.9) 0.24 (6) 0.60 (15) 0.75 (19) 1.18 (30) 1.38 (35) 1.78 (45) 2.56 (65) 15°
(56.5) ±5

2.66
Size 10 M 35 x 1.5 1.26 (32) 0.39 (10) 0.73 (18.5) 1.26 (31.9) 0.39 (10) 0.71 (18) 0.91 (23) 1.38 (35) 1.61 (41) 2.05 (52) 3.15 (80) 15°
(67.5) ±7

► Performance curves

Mesured at :
ƒƒ Viscosity v = 41 Cst
ƒƒ Temperature t = 122 °F (50°C).

SIZE 6 SIZE 10

400 400 600 600


500 500
300 300
400 400
Bar

Bar
Bar

Bar

200 200 300 300


200 200
100 100 100 100

0 050 0 0
25 25 30 60 50 80 120 30 60 80 120
Q [l/min] Q [l/min] Q [l/min] Q [l/min]

These dimensions inches (mm) are given as an indication.


28 Charging equipment

CH A R G I N G VA LV E S
The P 1620 universal valve exists in two versions:
ƒƒ P 1620: standard valve, thread M 16 x 200.
ƒƒ PX 1620: stainless steel valve, thread M 16 x 200.

Gas side
LEDUC Accumulator
Valve type Implantation Remark Charging device Adaptor
code type
A
310367 G 1/4 ACS-ACSL-AS-APL Standard
P1620
310379 M10 x 1.50 ABVE Standard M 16 x 2.00
VGL4
PX1620 310527 G 1/4 AS Stainless steel
V15N 310308 M10 x 1.50 ABVE Stainless steel 5/8’’ 18 UNF

M8 x 1.25
Screw 066542 with ring ACS - ACSL Standard VGL 4 None
BS 130331A

Schrader 067210 G1/4 ACS-ACSL-AS-APL VGL 4 8V1

Ø 0 79 (20)

LEDUC B C on flats
code inches (mm) inches (mm)
310367 1.42 (36) 0.75 (19)
B

310379 1.50 (38) 0.67 (17) C

310527 1.42 (36) 0.75 (19)

6 on flats M28x1 50

CH A R G I N G K IT CHARGING AND GAUGING DE VIC E

Reference : CGLU 4F 066650 Reference : VGL 4 066660


Includes: Description:
• VGL 4 universal pressure charging and gauging device The VGL 4 charging and gauging device is the essential instrument to
(M28 x 1.50 outlet); the checking and the nitrogen purge or the accumulator.
• one gauge pressure from 0 to 363 psi (0 to 25 bar); The VGL 4 includes:
• one gauge pressure from 0 to 3626 psi (0 to 250 bar); • a charging device VGL 4 for gas valve M 28 x 1,50;
(additional gauge pressure on request 0-450; 0-5800 psi (0-100 ; 0-400); • a manometer kit from 0 to 5800 psi (400 bar);
• adapters for connection to charging valves • an adapter for connection to gas valve M 16 x 200.
(M 16 x 200 - 5/8’’ 18UNF - G3/4’’ - 7/8’’ 14UNF - 8V1);
• 98.4 inches (2.50 m) -long hose, for connection to a source of nitrogen, Technical characteristics:
max. pressure at 5800 psi (400 bar) as standard (equipped with an • Max. pressure: 5800 psi (400 bar).
adaptation for french or german bottle); • Gauge pressure Ø 2.48 (63) with glycerin filled and quick connection G¼".
• 6 mm A/F Allen wrench; • Scale 0 to 5800 psi (400 bar) (or other on request) with accuracy of 1.6;
• spare seal kit. • The universal charging device has a female adapter
M28X1.50 - 0.23 inches (6 mm) A/F allen wrench.
Precautions and maintenance 29

► Installing your accumulator: Check that the hydraulic installation is capable of withstanding the
maximum service pressure engraved on the accumulator. Check that
Before installation, it is essential to visually check the accumulator for
maximum service pressure of the accumulator never exceeds the maxi-
any external damage.
mum service pressure engraved on the shell and on the name plate.
For optimal operation, the accumulator should be placed as close as
possible to the application. It should be installed in a vertical position
Volumetric ratio (V0-V2/V0) must not be exceeded, see page 5.
with the charging valve or screw at the top. For use in a horizontal posi-
tion, please contact our Technical Department. The accumulator should
Bleed the pipework of any air.
be installed in an easily accessible place and be fixed using robust
collars , a seat etc. ► Maintenance:

It is strictly forbidden to make any modification to the ƒƒ Before intervening on any circuit which has a gas filled pressure
accumulator (welding, grinding, machining etc.), or to change the vessel, the pressure must be discharged from the circuit.
information engraved on the accumulator. ƒƒ Check nitrogen pressure during the first few weeks of operation
and adjust the frequency of checks depending on application.
The circuit should include an isolation valve to isolate ƒƒ Ensure at every check that the accumulator has been isolated
the accumulator, and also a means of checking that the from the circuit, and that there is no more pressure in fluid side.
hydraulic pressure never exceeds the maximum service 1
Use the charging and gauging device VGL reference 066660
pressure engraved on the accumulator. The accumu- (see page 28).
lator must be connected to a relief valve  set at the 5
ƒƒ Be careful to use a manometer with a measuring range compati-
accumulator’s maximum authorized service pressure.
All of these functions are ensured by HYDRO LEDUC 2
3 ble with the nitrogen pressure to be checked.
safety and shut-off blocks BS1M and BS2M
4
ƒƒ Visually inspect the accumulator regularly for any signs of deteri-
(see pages 24-25). oration such as corrosion, deformation etc.
ƒƒ For cleaning recommendations and precautions : please contact
Check that the fluid is compatible with the materials used in the our Technical Department.
accumulator: the shell, elastomer, and the fluid used for the hydraulic ƒƒ For spare parts, only use LEDUC parts.
testing. ƒƒ The user is not authorized to change any part of the acuumulator
Suitable fluid : mineral-based hydraulic fluid or equivalent. without the manufacturer’s prior approval. An accumulator is
For other fluids, please consult our Technical Department. made up of sub-assemblies. Any modification not authorized
► Start up: by the manufacturer and its notified body invalidates the CE
certification of the whole accumulator.
Accumulators are supplied either with a pre-charge pressure for storage of
around 5 bar, or with pre-charge pressure as specified and corresponding ► Legislation
to the requirement calculated depending on working conditions. The pre-
Hydraulic accumulators are gas pressure vessels.
charge pressure is engraved on the accumulator shell.
The manufacture of such products must conform to Directive 2014/68/UE.
Pre-charge pressure of LEDUC accumulators (all sizes).
Local regulations and legislation must be strictly respected regarding the use of
For all pre-charge pressures greater than or equal to 20 bar, the tolerance accumulators.
is -29/+87 psi (-2/+6 bar).
For a tighter tolerance, please contact our Technical Department. ► Pressure Equipment Directive (PED) 2014/68/EU
All pre-charge pressures done by HYDRO LEDUC are adjusted at ambiant LEDUC accumulators of less than 1 litre capacity are supplied with a
temperature of 68°F (20°C). manufacturer’s certificate. They cannot be stamped CE, but conform to the
ƒƒ Pre-charge pressure should be checked before start-up : see the Directive 2014/68/UE.
recommendations sheet supplied with each accumulator. LEDUC accumulators of 1 litre capacity or more are supplied with a Certificate
ƒƒ Check pre-charge pressure, or charge to required pressure level, UE of conformity. They bear the CE stamp and the reference of the official
organisation certifying their conformity.
using the charging and gauging device (see page 24), see also
Use of these accumulators in France is governed by decree dated 15 March
instructions supplied with the device. The influence of tempera- 2000 (Official Bulletin n°96).
ture on pre-charge pressure must be taken into consideration.
ƒƒ Please note that a slight loss of nitrogen is possible when check- ► Useful addresses:
ing pre-charge pressure.
-- French legislation and application of directive 2014/68/UE:
It is strictly forbidden to use any gas containing oxygen or an air http://www.adminet.com/jo
compressor which would lead to danger of explosion. -- European legislation: http://europa.eu.int
Use only bottled dry nitrogen.
Independent approved organisations: APAVE, TÜV, VERITAS...

Determine the right LEDUC accumulator for your application:


Our calculations software, free of charge, is available by e-mail on
request.
30 The LEDUC range

P I S TO N PU MP S M OBILE & HYDRAULIC


F O R T RU C K S IN D USTRIAL PUM PS M OTORS

M/MA
MSI
X Pi/XAi TXV
D ELTA
index able Va r i a b l e
m o to r

HYDRO LEDUC offers 3 types of piston pumps The W range is composed of fixed Fixed and variable displacement piston motors
perfectly suited to all truck and PTO-mount displacement pumps, and the DELTA range, of ƒ Models from 0 31 to 11 02 cu in/rev
applications variable displacement pumps. These pumps (5 to 180 cc/rev)
can operate at high pressures within minimal ƒ Available in DIN and SAE versions
ƒ Fixed displacement from 0 73 to 7 93 size. ƒ In fixed displacement, special drainless
cu in/rev (12 to 130 cc/rev) motor
► W and WA (SAE)* pumps:
ƒ Fixed displacement, twin-flow,
from 2x 1.53 to 4.58 cu.in ƒ Fixed displac. from 0 73 to 7 65 cu in/rev
( 2x25 to 2x75 cc/rev) (12 to 125 cc/rev)
ƒ Variable displacement, with LS control ƒ ISO 3019/2 or SAE flanges.
(load sensing) from 2 44 to 9 15 cu in/ ƒ DIN 5480 or SAE shafts.
rev (40 to 150 cc/rev)
► DELTA pumps:
ƒ Variable displac. from 2 44
to 5 61 cu in/rev (40 to 92 cc/rev)
ƒ SAE shafts and flanges.

* For SAE version, please ask.


31

Complete catalogue available at www.hydroleduc.com

H Y D R O P N E U MAT IC M ICRO
A C C U M U LATO R S HYDRAULICS

A dedicated R&D team


means HYDRO LEDUC
is able to adapt or create
products to meet specific
customer requirements

Working in close cooperation


with the decision-making
Diaphragm, bladder, bladder-diaphragm and This is a field of exceptional HYDRO LEDUC teams of its customers,
piston accumulators know-how:
Capacities from 0 005 to 13 21 gallons
HYDRO LEDUC optimizes
(0 02 to 50 liters) ƒ Axial and radial piston pumps, of fixed proposals based on the
and variable displacement specifications submitted.
ƒ Operating pressure up to 5800 psi 400 bar ƒ Axial piston micro-hydraulic motors
ƒ Accessories for use with hydraulic ƒ Micro-hydraulic units incorporating
accumulators pump, electric motors, valving, controls,
etc

HYDRO LEDUC offers complete, original and


reliable solutions for even the most difficult
environments, and within the smallest size
envelopes

µ
A passion for hydraulics

HYDRO LEDUC SAS


Head Office & factory
BP 9 - F-54122 AZERAILLES
FRANCE
Tél . +33 (0)3 83 76 77 40
Fax +33 (0)3 83 75 21 58

HYDRO LEDUC GmbH


Haselwanderstr. 5
D-77746 SCHUTTERWALD
DEUTSCHLAND
Tel. +49 (0) 781-9482590
Fax + 49 (0) 781-9482592

HYDRO LEDUC AB
Betongvägen 11
461 38 TROLLHÄTTEN
SWEDEN
Tel. 46 (0) 520 10 820

HYDRO LEDUC BV
Graaf Engelbertlaan 75
4837 DS Breda
THE NETHERLANDS
+31 6 202 40 651

HYDRO LEDUC N.A. Inc.


19416 Park Row - Suite 170
HOUSTON, TEXAS 77084
USA
Tel. +1 281 679 9654
Fax +1 832 321 3553

m��� i� ������ HYDRO LEDUC


SAS au capital de 4 065 000 €
EORI FR31902742100019
RC Nancy B 319 027 421

www.hydroleduc.com contact@hydroleduc.com

US_ACCUS_20180420

You might also like