Professional Documents
Culture Documents
Salmo 6579
Salmo 6579
Methods
DOI 10.1007/s12161-016-0602-7
Abstract An alternative method for detection of Salmonella inclusive and 100 % exclusive. The interlaboratory trial in-
spp. in animal feed, based on the use of loop-mediated ampli- volved ten laboratories from eight European countries, testing
fication (LAMP) in conjunction with a standard culturing pro- eight samples at three contamination levels: 0 cfu/100 g, 1–
cedure, was compared with the standard ISO 6579 as refer- 5 cfu/100 g and 14–68 cfu/100 g. The trial specificity, or
ence method, using soya meal as the test matrix. In the method percentage correct identification of uncontaminated samples,
comparison study, the sensitivities for both the alternative and was 96.3 % for both the reference methods and the
reference methods were 100 %. The relative level of detection LAMP/ISO 6579 alternative method, thus demonstrating its
was 1.000. Tested against 100 Salmonella and 30 non- suitability for adoption as a procedure for rapid identification
Salmonella strains, the LAMP-based method was 99 % of Salmonella uncontaminated soya meal.
1
Food and Environment Research Agency (FERA), North
Yorkshire, UK Introduction
2
Present address: Campden BRI, Station Road, Chipping Campden,
Gloucestershire GL55 6LD, UK Currently, analysis of animal feed for Salmonella is generally
3
Danish Meat Research Institute, Taastrup, Denmark performed using the standard ISO 6579:2002 (Anonymous,
4
Agricultural University of Athens, Athens, Greece
2002). ISO 6579 is based on bacterial culturing followed by
5
biochemical tests. This enables the identification of uncon-
University of Patras, Patras, Greece
taminated samples in 3 days; any presumptive positive
6
Teagasc Food Research Centre, Dublin, Ireland Salmonella isolated from a sample at that time are confirmed
7
Istituto Superiore di Sanita, Rome, Italy through further growth on selective media, and biochemical
8
National Veterinary Research Institute, Pulawy, Poland testing, in 7 days. To provide more rapid screening for
9
Scientific Veterinary Institute BNovi Sad^, Novi Sad, Serbia
Salmonella-free samples, a loop-mediated amplification
10
(LAMP)-based method has been developed for the analysis
Instituto Tecnológico Agrario de Castilla y León (ITACyL),
Valladolid, Spain
of animal feed for the presence of Salmonella spp.
11
(D’Agostino et al., 2015). LAMP is a nucleic acid amplifica-
University of Burgos, Burgos, Spain
tion technique that operates isothermally without the need for
12
Nottingham Trent University, Nottingham, UK complex thermocycling instrumentation (Notomi et al., 2000).
13
Queen’s University Belfast, Belfast, UK The LAMP-based method is compatible with the standard
Food Anal. Methods
culture based method ISO 6579, as the first steps of both stuffs – Horizontal method for the detection of Salmonella
methods—pre-enrichment of the sample in buffered peptone spp.^ with the following exceptions:
water—are the same. This novel method allows identification
of uncontaminated samples in 2 days, which would provide a 1. For primary enrichment of the sample, 100 g soya meal
significant time saving during routine use. was added to 900 ml room temperature-buffered peptone
In the originating laboratory, the method of D’Agostino water (BPW; Oxoid, Basingstoke, UK).
et al. (2015) worked consistently and efficiently. However, it 2. Secondary enrichment was performed using only the
is well known that the results of methods developed and pub- Rappaport-Vassiliadis medium with soya (RVS broth;
lished by one laboratory can sometimes be difficult to repro- Oxoid, Basingstoke, UK).
duce in other laboratories. The ability to reproduce results 3. Plating out was performed using only xylose lysine
successfully in different laboratories is an absolute prerequi- desoxycholate agar (XLD; Oxoid, Basingstoke, UK).
site for adoption of a detection method as a routine diagnostic
tool (Rodriguez-Lazaro and Hernandez, 2016). Validation of Biochemical characterisation of presumptive positive col-
any method should be necessary for its adoption as a standard onies was performed using the API20e kit (bioMérieux,
(Jones and Marengo, 2016). The international standard proce- Basingstoke, UK).
dure ISO 16140:2016 (Anonymous, 2016) can be used to Samples were considered as uncontaminated by
demonstrate that the performance characteristics of a novel Salmonella if, after examination of the selective agar plates,
method are at least as good as those of a standard method, no typical or atypical colonies (as described in Section 9.4 of
and thereby validate the newer method. Validation strictly the standard) were present. Samples were considered as con-
according to ISO 16140:2016 is however very intensive and taminated by Salmonella if any typical or atypical colonies
requires substantial resource. In this report, validation of the which were present were confirmed as being Salmonella
method of D’Agostino et al. (2015) against the method of through biochemical testing as specified in the standard.
Anonymous (2002) has been performed based partially on
Anonymous (2016). This is the first reported validation of a
LAMP-based method as an alternative to an existing standard Loop-Mediated Amplification/ISO 6579-Based Method for
method. Analysing Animal Feed for the Presence of Salmonella The
alternative detection method was described in D’Agostino
et al. (2015). Samples comprising 100 g feed were pre-
Materials and Methods enriched in 900 ml buffered peptone water, and then
2 × 100 μl aliquots were taken, one for secondary enrichment
Salmonella Strains Bespoke LENTICULE® discs were ob- in a LAMP-friendly broth and the other for secondary enrich-
tained from Public Health England (PHE; Colindale, London, ment according to ISO 6579:2002. A 3 μl aliquot of the
UK), containing a low level of Salmonella enterica subsp. LAMP-friendly culture was added directly into a LAMP reac-
Enterica serovar Typhimurium (expected range of 1–5 tion. The LAMP assay incorporated an internal amplification
colony-forming units [cfu] per disc). PHE also supplied a control (IAC); the target and IAC signals were distinguished
bespoke set of Bblank^ lenticules containing no microorgan- by the difference in annealing temperatures of the amplicons.
isms. Lenticules containing a medium level of Salmonella Samples were considered as uncontaminated by Salmonella if
enterica subsp. Enterica serovar Typhimurium (expected no target signal was obtained but a IAC signal was present
range of 14–68 cfu per disc) were available as an Boff-the- indicating that no inhibition had occurred during the LAMP
shelf^ product from PHE. Other Salmonella serotypes were reaction. Samples were considered as presumptively contam-
obtained from the Food and Environment Research Agency inated by Salmonella if target signals were obtained; confir-
(FERA)’s in-house culture collection. mation was performed by continuation of ISO 6579:2002,
with biochemical testing (e.g. utilisation of citrate, fermenta-
Inclusivity and Exclusivity Test Strains All non-Salmonella tion of sucrose) performed using the API 20E kit.
strains used in this study are listed in Table 3.
Animal Feed Soya meal was used as a representative animal Principle of the Validation
feed. Soya meal was kindly supplied by John Thompson and
Sons Ltd., Belfast, UK. The principles of the validation were adapted from FDIS ISO
16140–2:2015. However, due to reasons of limited resource
Detection of Salmonella Spp. in Animal Feed by ISO 6579 available within the study, adherence to the exact procedures
The reference method used was based on that described in was restricted. The study comprised two main parts: a method
BISO 6579:2002 - Microbiology of food and animal feeding comparison study and an interlaboratory trial.
Food Anal. Methods
Table 2 Summary of the results for the various descriptors in the paired as follows: specificity for the reference method and the alter-
sensitivity study of the reference method ISO 6579 for the detection of
native method, and sensitivity for the reference method and
Salmonella in animal feed and the alternative method of D’Agostino
et al. (2015) the alternative method.
*Field isolate
†Obtained from Public Health England
Food Anal. Methods
L0 L1 L2
Presumptive positive Confirmed positive Presumptive positive Confirmed positive Presumptive positive Confirmed positive
Table 6 Percentage specificity of the reference method (ISO 6579) and Salmonella-contaminated soya meal was not available during
the alternative method (LAMP/ISO 6579)
this study, and therefore artificially contaminated samples were
Descriptor Formula Value (%) used instead (as has been done in other validation studies e.g.
Delibato et al., 2014; Maurischat et al., 2014). Anonymous
Specificity for the (1 − ((C)P0/N_)) × 100 96.3 (2016) recommends (although does not mandate) that artificial
reference method (SPref)
Specificity for the (1 − ((C)P0/N_)) × 100 96.3
contamination levels lower than 1 cfu are used, to achieve frac-
alternative method (SPalt) tional recovery in the RLOD study. However, the lowest artificial
contamination level in this study was 1 cfu (assuming that some
(C)P0 is the total number of false-positive results obtained with blank of the low level lenticules contained this minimum quantity).
samples using the alternative method before and after additional confir-
mation. N_ is the number of all L0 tests
Although therefore the validation standard was not adhered to
precisely, it may still be concluded that using a very low artificial
contamination level can reflect natural contamination situations.
Discussion Therefore, with the RLOD in this study being 1.000, the method
of D’Agostino et al. (2015) can reasonably be considered to be
Alternative methods for Salmonella detection, based on the equivalent to the standard method with regard to their respective
polymerase chain reaction (PCR), have been published levels of detection of Salmonella.
(Delibato et al., 2014; Maurischat et al., 2014; McCabe One Salmonella strain (S. enterica subsp. arizonae) failed
et al., 2011), but this is the first report of a validation of a to amplify during the inclusivity testing, thus affecting the
LAMP-based method for detection of Salmonella, as an alter- specificity value. The reason for this failure is unknown. The
native to an existing standard method. The study performed LAMP assay used the primers designed by Hara-Kudo et al.
here is referred to in Anonymous (2016) as a BPaired^ trial. (2005); these authors found that they were able to mediate the
This means that the 1° enrichment broth is the same for the detection of all seven strains of S. enterica subsp. arizonae
reference method as it is for the alternative method. Due to which they tested. Although it has been occasionally isolated
resource limitations, it was only possible within this study to from food (Hall and Rowe, 1992), S. enterica subsp. arizonae
use one feed matrix, soya meal, for the validation; other is not a common foodborne Salmonella and is usually associ-
molecular-based method validation studies using the approach ated with those who handle reptiles or travel abroad (Di Bella
of ISO 16140 have likewise used only one matrix (Delibato et al., 2011). There are no reports of this bacterium being
et al., 2014; Maurischat et al., 2014). In a previous study isolated from animal feed.
(D’Agostino et al., 2015), seven other animal feed types (corn In the interlaboratory study, it was decided for reasons of
gluten, distillers grains, rape meal, fish meal, microalgae bio- cost and logistics not to send out Salmonella-contaminated
mass powder, organic full fat soya and whole rape) were suc- soya meal samples which were prepared in the originating lab-
cessfully analysed by the LAMP-based method. The LAMP- oratory. The use of commercially available certified Salmonella
based method validated on soya meal should be generically reference materials was considered advantageous, as they were
applicable to these other feed types. supplied directly to the participants by the manufacturer, and as
In the sensitivity study performed during the method compar- they were stabilised materials it reduced the possibility of fluc-
ison study, the AL values of ND − PD and ND + PD were both tuating temperatures during transit affecting the viability thus
zero, and thus below the parameters of 3 and 6 as prescribed in introducing unacceptable variation into the trial. On the other
Anonymous (2016) for one category of feed type. The method of hand, the natural variation created by the participants’ prepara-
D’Agostino et al. (2015) is thus within the limits of acceptability tion of the growth medium is an advantage, as the validation
for sensitivity as an alternative method to the use of ISO 6579 protocol (ISO 16140) recommends natural variability during
alone for detection of Salmonella in soya meal. the trial in order to provide more robustness to the data.
Ideally, to follow the method prescribed in Anonymous During the interlaboratory trial, one laboratory reported two
(2016) exactly, naturally contaminated samples would have been false-positive results and another laboratory reported one false-
used, particularly for the sensitivity study. However, naturally positive result. However, there was no evidence of deviation