Tech Planner
Tech Planner
14/08/2019
Content
Post office building
Luminaire list............................................................................................................................................................................................................. 3
Control groups...........................................................................................................................................................................................................4
Post office building
Glamox - C92-R625X625 LED 3200 840 MP (1xLED C92-R 3200 840)......................................................................................................... 5
Philips - RC125B W60L60 1 xLED36S/840 NOC (1xLED36S/840/-)...............................................................................................................8
Philips - RC484B W60L60 VPC 1xLED78S/TWH-3100 AC-MLO (1xLED78S/TWH-3100)...........................................................................11
Post offic
Post Ofiice Building
Storey 1
COnfre
Summary............................................................................................................................................................................................... 14
Luminaire layout plan............................................................................................................................................................................ 15
Luminaire list......................................................................................................................................................................................... 16
Page 2
Post office building 14/08/2019
Colourimetric data
1xLED C92-R 3200 840: CCT 4000 K, CRI 80
2969 lm
Colourimetric data
1xLED36S/840/-: CCT 3000 K, CRI 100
Colourimetric data
1xLED78S/TWH-3100: CCT 3000 K, CRI 100
Total lamp luminous flux: 920191 lm, Total luminaire luminous flux: 919319 lm, Total Load: 9274.0 W, Luminous efficacy: 99.1 lm/W
Page 3
Post office building 14/08/2019
Light scene -E
Control group Dimming values Control group Dimming values Control group Dimming values
Control group 35 100% Control group 36 0% Control group 37 100%
Life Safety
Control group Dimming values Control group Dimming values Control group Dimming values
Control group 35 0% Control group 36 0% Control group 37 100%
Page 4
Post office building 14/08/2019
Post offic / Post Ofiice Building / Storey 1 / Glamox C92-R625X625 LED 3200 840 MP 1xLED C92-R 3200 840 / Glamox - C92-
R625X625 LED 3200 840 MP (1xLED C92-R 3200 840)
Driver
HF or DALI. Driver life time up to 100.000 h/10 % (max failure) at Ta
25°C.
Mounting
C92-R is specifically designed to accommodate 35mm asymmetric
concealed T Bar ceiling tiles like Troldtekt T35 and OWA S 9a. C92-R
includes four mounting brackets that needs to be folded out in the
ceiling in order to mount it.
Mounted in cluster:
Absolute photometry As with conventional light sources you may perceive variations in
Luminaire luminous flux: 2969 lm colour temperature between luminaires mounted close together
Power: 24.0 W (cluster). Colour tolerances for LED light sources are normally better
Luminous efficacy: 123.7 lm/W or the same as for conventional light sources. For more information,
please contact any member of our sales staff.
Colourimetric data
1xLED C92-R 3200 840: CCT 4000 K, CRI 80 Optics
Standard with micro prismatic (MP) or Opalic (OP) in acrylic.
IK10 with diffusor made of polycarbonate (PC).
Luminous emittance 1 / Polar LDC
Sensors
105° 105°
Daylight and presence sensor (D2-SEN)
90° 90°
Emergency system
Standard (S), Self test (ST) or DALI. 1h or 3h.
75° 75°
400
60° 60°
600
800
45° 45°
1000
1200
cd 2969 lm
C0 - C180 C90 - C270
Page 5
Post office building 14/08/2019
Post offic / Post Ofiice Building / Storey 1 / Glamox C92-R625X625 LED 3200 840 MP 1xLED C92-R 3200 840 / Glamox - C92-
R625X625 LED 3200 840 MP (1xLED C92-R 3200 840)
1200
1000
800
600
400
200
E(0°) 5470
1.1 E(C90) 46.4° 902
0.50 1.1 E(C0) 46.7° 884
E(0°) 1367
2.1 E(C90) 46.4° 226
1.0 2.1 E(C0) 46.7° 221
E(0°) 608
3.2 E(C90) 46.4° 100
1.5 3.2 E(C0) 46.7° 98
E(0°) 342
4.2 E(C90) 46.4° 56
2.0 4.2 E(C0) 46.7° 55
E(0°) 219
5.3 E(C90) 46.4° 36
2.5 5.3 E(C0) 46.7° 35
E(0°) 152
6.3 E(C90) 46.4° 25
3.0 6.4 E(C0) 46.7° 25
Page 6
Post office building 14/08/2019
Post offic / Post Ofiice Building / Storey 1 / Glamox C92-R625X625 LED 3200 840 MP 1xLED C92-R 3200 840 / Glamox - C92-
R625X625 LED 3200 840 MP (1xLED C92-R 3200 840)
C270 C90
800
1200
2000
C315 C0 C45
cd/m²
g = 65.0° g = 75.0° g = 85.0°
The UGR values are calculated in acc. with CIE Publ. 117. Spacing-
to-Height-Ratio = 0.25
Page 7
Post office building 14/08/2019
Post offic / Post Ofiice Building / Storey 1 / Philips RC125B W60L60 1 xLED36S/840 NOC 1xLED36S/840/- / Philips - RC125B
W60L60 1 xLED36S/840 NOC (1xLED36S/840/-)
Colourimetric data
1xLED36S/840/-: CCT 3000 K, CRI 100
90° 90°
75° 75°
60° 60°
160
45° 45°
240
cd/klm η = 100%
C0 - C180 C90 - C270
Page 8
Post office building 14/08/2019
Post offic / Post Ofiice Building / Storey 1 / Philips RC125B W60L60 1 xLED36S/840 NOC 1xLED36S/840/- / Philips - RC125B
W60L60 1 xLED36S/840 NOC (1xLED36S/840/-)
300
250
200
150
100
50
E(0°) 4784
1.3 E(C90) 52.6° 537
0.50 1.9 E(C0) 62.4° 238
E(0°) 1196
2.6 E(C90) 52.6° 134
1.0 3.8 E(C0) 62.4° 60
E(0°) 532
3.9 E(C90) 52.6° 60
1.5 5.7 E(C0) 62.4° 26
E(0°) 299
5.2 E(C90) 52.6° 34
2.0 7.7 E(C0) 62.4° 15
E(0°) 191
6.5 E(C90) 52.6° 21
2.5 9.6 E(C0) 62.4° 9.5
E(0°) 133
7.8 E(C90) 52.6° 15
3.0 11 E(C0) 62.4° 6.6
Page 9
Post office building 14/08/2019
Post offic / Post Ofiice Building / Storey 1 / Philips RC125B W60L60 1 xLED36S/840 NOC 1xLED36S/840/- / Philips - RC125B
W60L60 1 xLED36S/840 NOC (1xLED36S/840/-)
C270 C90
2000
5000
C315 C0 C45
cd/m²
g = 65.0° g = 75.0° g = 85.0°
The UGR values are calculated in acc. with CIE Publ. 117. Spacing-
to-Height-Ratio = 0.25
Page 10
Post office building 14/08/2019
Post offic / Post Ofiice Building / Storey 1 / Philips RC484B W60L60 VPC 1xLED78S/TWH-3100 AC-MLO 1xLED78S/TWH-3100 /
Philips - RC484B W60L60 VPC 1xLED78S/TWH-3100 AC-MLO (1xLED78S/TWH-3100)
Colourimetric data
1xLED78S/TWH-3100: CCT 3000 K, CRI 100
90° 90°
75° 75°
200
60° 60°
300
600
cd/klm η = 100%
C0 - C180 C90 - C270
Page 11
Post office building 14/08/2019
Post offic / Post Ofiice Building / Storey 1 / Philips RC484B W60L60 VPC 1xLED78S/TWH-3100 AC-MLO 1xLED78S/TWH-3100 /
Philips - RC484B W60L60 VPC 1xLED78S/TWH-3100 AC-MLO (1xLED78S/TWH-3100)
500
400
300
200
100
E(0°) 8074
0.50 0.99 E(C0) 44.8° 1444
E(0°) 2018
1.0 2.0 E(C0) 44.8° 361
E(0°) 897
1.5 3.0 E(C0) 44.8° 160
E(0°) 505
2.0 4.0 E(C0) 44.8° 90
E(0°) 323
2.5 5.0 E(C0) 44.8° 58
E(0°) 224
3.0 6.0 E(C0) 44.8° 40
Page 12
Post office building 14/08/2019
Post offic / Post Ofiice Building / Storey 1 / Philips RC484B W60L60 VPC 1xLED78S/TWH-3100 AC-MLO 1xLED78S/TWH-3100 /
Philips - RC484B W60L60 VPC 1xLED78S/TWH-3100 AC-MLO (1xLED78S/TWH-3100)
C270 C90
800
1200
2000
2400
C315 C0 C45
cd/m²
g = 65.0° g = 75.0° g = 85.0°
The UGR values are calculated in acc. with CIE Publ. 117. Spacing-
to-Height-Ratio = 0.25
Page 13
Post office building 14/08/2019
COnfre
Clearance height: 2.550 m, Reflection factors: Ceiling 70.0%, Walls 13.4%, Floor 15.0%, Maintenance factor: 0.80
Lighting power density: 6.75 W/m² (Floor area of room 85.37 m²),
Lighting power density: 11.45 W/m² (Area of working plane 50.33 m²)
The energy consumption quantities do not take into account light scenes and their dimming levels.
Page 14
Post office building 14/08/2019
Post offic / Post Ofiice Building / Storey 1 / COnfre / Luminaire layout plan
COnfre
Page 15
Post office building 14/08/2019
COnfre
Quantity Luminaire (Luminous emittance)
24 Glamox - C92-R625X625 LED 3200 840 MP
Luminous emittance 1
Fitting: 1xLED C92-R 3200 840
Absolute photometry
Luminaire luminous flux: 2969 lm
Power: 24.0 W
Luminous efficacy: 123.7 lm/W
Colourimetric data
1xLED C92-R 3200 840: CCT 4000 K, CRI 80
2969 lm
Total lamp luminous flux: 71256 lm, Total luminaire luminous flux: 71256 lm, Total Load: 576.0 W, Luminous efficacy: 123.7 lm/W
Page 16