Table A – Cement Content and W/C Ratio for Concrete Modifications to ASTM C94/
Item Structural Concrete Non-structural Concrete Silica fume, when used as replacement
Cement Content for cement in concrete, it shall not be
Min.
Max. 370 Min. 350 Max. - less than 7% and shall not exceed 10%
(Kg/M3) 250
by weight of cement.
W/C Ratio 0.4 - 0.6 -
28-Days Design Comp. (28 Mpa) (14 Mpa) Commentary Note:
Strength (ASTM - -
4000 PSI 2000 PSI When silica fume is used in
C39/C39M)
combination with other mineral
Precast & Prestressed CONCRETE SLUMP admixtures, minimum value of silica
Concrete & Water fume can be 5%.
Nom. 150mm (+/-40mm)
Retaining Structures
Cement Content
Ready Mix Concrete
All ready-mix concrete shall be delivered to the site with a batch ticket listing
the following:
Name of the ready-mix company
Serial number of the ticket, date, truck number
Name of purchaser
Name of the job and location
Saudi Aramco mix design number
Amount of concrete in cubic meters (or yards)
Time of loading if wet mix
Amount of water added by the receiver of concrete with his initials
Reading of the revolution counter at the first addition of water
Type, brand and amount of cement, silica fume, aggregates and admixtures
Truck mixing is allowed if the discharge of the concrete cannot be achieved
within 90 minutes after introduction of the mixing water to the cement and
aggregates or before the drum of the truck has revolved 300 revolutions,
provided that:
The discharge of the concrete shall be completed within three hours or before
the drum of the truck has revolved 600 revolutions, whichever comes first PREBARED BY: ENG/ IBRAHIM NAGUIB