Professional Documents
Culture Documents
Register User Forum List Calendar Active Topics FAQ
Register User Forum List Calendar Active Topics FAQ
Register User Forum List Calendar Active Topics FAQ
Topic Options Who's Online
Pipe rack design #41106 - 02/18/11 06:01 PM
0 registered (), 41
Guests and
1 Spider
Nodal
online.
Member
I want to know some basic thumb rules to give pipe rack loading Key:
Admin,
Global Mod,
to structural, without doing any formal stress analysis. Mod
Registered:
10/07/09
Posts: 20
I heard about some UDL concept but do not much November
Loc: Canada
Su
M
Tu
W
Th
F
Sa
Any help will be highly appreciated.
1 2
Thanks, 3 4 5 6 7 8 9
10 11 12 13 14 15 16
Top
17 18 19 20 21 22 23
Re: Pipe rack design
[Re: Nodal] #41110 - 02/19/11 02:04 AM 24 25 26 27 28 29 30
stressguy81
Forum Stats
Vertical Loads:
11720 Members
Member
Generally Pipe size 10" Lines and below are given as UDL and
14 Forums
other larger bore dia as point load.
Registered: 16052 Topics
07/03/08
71945 Posts
Posts: 71
Incase you want actual UDL for Pipe size 10" and below pipes,
Loc: India calculate the dead weight,operating and hydro weight considering
Max Online: 126 @
pipes to be supported as simply supported beam. 05/09/18 04:29 PM
Based on the intermediate beams(span) and pipe rack width
(occupied width) covert reaction to UDL either KN/m2 or KN/m.
Top Posters (30
In case of vertical load (UDL) for Dia 10" and below a minimum Days)
of 1.75KN/m2 may be used.
Michael_Fletcher 19
Horizontal loads: Vanman 15
For high temperature lines(typically greater than 200 Deg C) and Chill-N 15
Pipe size greater than 10", perfrom stress analysis to get lateral vermaccio 13
loads and axial loads, Richard Ay 13
For other lines(<=10") use limiting friction value to get horizontal
loads.
Top
Re: Pipe rack design
[Re: stressguy81] #41152 - 02/22/11 12:40 AM
stress river
stressguy81:
Member
Posts: 81
thanks
Loc: china
b regards
_________________________
Know what you are doing!
Top
Re: Pipe rack design
[Re: stress river] #41189 - 02/23/11 07:24 AM
stressguy81
Vertical loads:
Member
While doing pipe rack loading/ sleeper loading for Proposal jobs
or early stages of detailed engineering, getting Actual "Point
Registered:
07/03/08
Typically for a Rack, vertical load (UDL) for Dia 10" and below a
minimum of 1.75KN/m2 is good to go.
Horizontal loads:
Top
Previous Topic
Index
Next Topic
Tweet
.
Moderator: Dave Diehl, Richard Ay
Hop to:
CAESAR
CAESAR IIII
Go
Privacy statement ·
Board Rules · Mark all read
Contact Us
·
Home Page
·
Top
GooG_v2_copy_copy_copy
GooG_v2_copy_copy_copy
Generated in 0.019 seconds in which 0.006 seconds were spent on a total of 14 queries. Zlib compression disabled.
Powered by UBB.threads™ 7.5.7