Bilant termic

Qcedat=Qprimit

Qprimit=mr*e*r

Qprimit= 2036666.66666667 J/s


Qprimit= 2036.667 kW

Qcedat=mc*cp*Δtc
cp mot =[(2964-1332*d)+(6.148-2.308*d)*t]*(0,0538*K+0.3544)
cp mot= 2796.59 J/kg°C

Qcedat=Qprimit
mc*cp*Δtc=mr*e*r

mc=(mr*e*r*1000)/cp*Δtc
mc= 14.565 kg/s

Qcedat=mc*Cpmot*Δtc
Qcedat= 2036666.66666667 J/s
Qcedat= 2036.667 kW

Verificare mc si Qcedat
Qcedat=mc*cp*Δtc=mc* ( ic1 – ic2)
i=((2.964-1.332*d15/15)*t+(0.003074-0.001154*d15/15)*t^2)*(0.0538*KkJ/kg
ic1= 691.58 kJ/kg
ic2= 551.75 kJ/kg

mc* ( ic1 – ic2) =mr*e*r

mc=(mr*e*r)/( ic1 – ic2)


mc= 14.565 kg/s
Qcedat=mc* ( ic1 – ic2)
Qcedat= 2036.6666666667 kW
r= 244.4 kJ/kg
mr=50 t/h= 13.89 kg/s
d4/20= 0.86 g/cm3
d15/15==0.9952*d4/20+0. 0.8639 g/cm3
k= 11
tc1= 300 °C
tc2= 250 °C
tr1= 194.6 °C
tr2= 194.6 °C
de= 0.025 m
di= 0.02 m
e= 0.6
P= 5 bar
tm=(tc1+tc2)/2 275 °C
Δtc=tc1-tc2 50 °C