Professional Documents
Culture Documents
Pdesign: 100 Barg Line Pipe Material: API Grade X60
Pdesign: 100 Barg Line Pipe Material: API Grade X60
ZONE 1
HOOP STRESS
ZONE 2
ZONE 2
Design factor (F for Zone 2) 0.50 0.50 0.50 0.50
Calculeted Wall thickness (tcal) mm 12.816 11.589 10.824 9.597
PROPAGATION BUCKLING
Propagating pressure (Ppr) 1.767 2.468 2.128 3.259
Check with formula:
Pe<(Ppr/ym*ysc) PASS PASS PASS PASS
Units Value
Input Parameters
PRESSURE CONTAINMENT (BURSTING) (Check in accordance with DNV 2007: Sec. 5; P.46)
Pressure containment resistance (Pb) Mpa 23.43 26.873 25.12
Incidental pressure ( Pinc) Mpa 15.40 15.40 15.40
Local incidental pressure (Pli) Mpa 15.536 15.536 15.536
Elevation of the reference point ( href) m 20.00 20.00 20.00
Elevation of the local pressure point (hl)(positive
upwards) m -59.30 -59.30 -59.30
Content density kg/m3 175.20 175.20 175.20
External pressure( Pe) Mpa 0.596 0.596 0.596
Yeild stress (fy) Mpa 423.36 423.36 423.36
Tensile strength (fu) Mpa 503.04 503.04 503.04
fcb = Min[fy;(fu/1.15)] 423.36 423.36 423.36
Material resistance factor (ym) 1.15 1.15 1.15
Safety class resistance factor (ysc) 1.308 1.308 1.308
De-rating values due to temperature of yeild stress
(fy.tem) Mpa 7.00 7.00 7.00
De-rating values due to temperature of tensile
strength (fu.tem) Mpa 7.00 7.00 7.00
Minimum wall thickness (t1) mm 9.51 9.51 8.11
Wall thickness withoat tcor(t2) mm 11.30 11.30 9.70
Fabrication thickness tolerance mm 1.788 1.788 1.588
Material strenght factor (au) 0.960 0.960 0.960
Check with formula (Pli-Pe)<=(Pb/ym.ysc) PASS PASS PASS
LOCAL BUCKLING ( SYSTEM COLLAPSE)(Check in accordance with DNV 2007: Sec. 5; P.46)
ZONE 2
Design factor (F for Zone 2) 0.50 0.50 0.50
Calculeted Wall thickness (tcal) mm 15.700 14.113 13.122
Selected Wall thickness (tcal) mm 17.800 15.900 14.300
PRESSURE CONTAINMENT (BURSTING) (Check in accordance with DNV 2007: Sec. 5; P.46)
Pressure containment resistance (Pb) Mpa 31.219 30.953 29.583
Incidental pressure ( Pinc) Mpa 15.400 15.400 15.400
Local incidental pressure (Pli) Mpa 15.536 15.536 15.536
Elevation of the reference point ( href) m 20.000 20.000 20.000
Elevation of the locol pressure point (hl)(positive
upwards) m -59.300 -59.300 -59.300
Content density kg/m3 175.200 175.200 175.200
External pressure( Pe) Mpa 0.596 0.596 0.596
Yeild stress (fy) Mpa 423.360 423.360 423.360
Tensile strength (fu) Mpa 503.040 503.040 503.040
fcb = Min[fy;(fu/1.15)] 423.360 423.360 423.360
Material resistance factor (ym) 1.150 1.150 1.150
Safety class resistance factor (ysc) 1.308 1.308 1.308
De-rating values due to temperature of yeild stress
(fy.tem) Mpa 7.00 7.00 7.00
De-rating values due to temperature of tensile
strength (fu.tem) Mpa 7.00 7.00 7.00
Minimum wall thickness (t1) mm 12.575 10.913 9.513
Wall thickness withoat tcor(t2) mm 14.800 12.900 11.300
Fabrication thickness tolerance mm 2.225 1.988 1.788
Material strenght factor (au) 0.96 0.96 0.96
Check with formula (Pli-Pe)<=(Pb/ym.ysc) PASS PASS PASS
LOCAL BUCKLING ( SYSTEM COLLAPSE)(Check in accordance with DNV 2007: Sec. 5; P.46)
Elastic collapse pressure (Pel) Mpa 21.973 21.719 19.318
Plastic collapse pressure (Pp) Mpa 30.835 30.716 29.540
Maximum fabrication factor (afab: for seamless) 1.000 1.000 1.000
Ovality ( fo) 0.015 0.015 0.015
Collapse pressure ( Pc) = y-1/3*b Mpa 16.373 16.301 14.864
Parameter b = -Pel -21.973 -21.719 -19.318
Parameter c = -( PP^2+ Pp*Pel*f0*(D/t)) -1182.850 -1167.290 -1066.480
Parameter d = Pel *Pp^2 20891.935 20491.718 16856.836
Parameter u = (1/3)*((-1/3)*b^2 +c) -447.928 -441.510 -396.958
609
D=10"
207,000.00
448.00
531.00
0.30
1,025.00
9.81
59.30
14.00
20.70
60.00
3.00
1.00
273.10
1.00
0.72
8.93
12.70
14.00
144.12
322.56
PASS
29.93
15.40
15.536
20.00
-59.30
175.20
0.596
423.36
503.04
423.36
1.15
1.308
7.00
7.00
8.11
9.70
1.588
0.960
PASS
20.385
30.074
1.00
0.015
15.657
-20.385
-1,102.186
18,436.936
-413.567
5,160.070
2.231
8.862
3.523
PASS
0.50
11.534
14.300
127.992
224.00
PASS
46)
35.284
15.400
15.536
20.000
-59.300
175.200
0.596
423.360
503.040
423.360
1.150
1.308
7.00
7.00
9.513
11.300
1.788
0.96
PASS
46)
32.228
35.035
1.000
0.015
22.298
-32.228
-1550.866
39556.905
-632.358
10208.591
2.268
11.555
5.160
PASS
IN CASE:
MAOP = 100 Barg
Pdesign = 110 Barg
Line pipe Material: API Grade X65
Units Value
Input Parameters
Specified Minimum Tensile Strength (SMTS) Mpa 531.00 531.00 531.00 531.00
Poisson's ratio(ν) 0.30 0.30 0.30 0.30
Water density kg/m^3 1,025.00 1,025.00 1,025.00 1,025.00
Gravity acceleration (g) m/c^2 9.81 9.81 9.81 9.81
Maximum water depth m 59.30 59.30 59.30 59.30
Calculated Wall thickness (tcal) for Zone 1 mm 9.93 9.06 8.52 7.66
Selected Wall thickness (t) for Zone 1 mm 12.70 11.90 11.10 11.10
HOOP STRESS ( Check in with B31.8: Section A842.221)
Internal Pressure (Pi) Mpa 11.00 11.00 11.00 11.00
Hoop stress (Sh) Mpa 166.46 155.44 151.79 127.98
Allowable Hoop stress Mpa 322.56 322.56 322.56 322.56
Check with formula: Sh<=allowable hoop
stress PASS PASS PASS PASS
PRESSURE CONTAINMENT (BURSTING) (Check in accordance with DNV 2007: Sec. 5; P.46)
Pressure containment resistance (Pb) Mpa 19.91 20.814 20.69 24.64
Incidental pressure ( Pinc) Mpa 12.10 12.10 12.10 12.10
Local incidental pressure (Pli) Mpa 12.212 12.212 12.212 12.212
Elevation of the reference point ( href) m 20.00 20.00 20.00 20.00
Elevation of the local pressure point (hl)(positive
upwards) m -59.30 -59.30 -59.30 -59.30
LOCAL BUCKLING ( SYSTEM COLLAPSE)(Check in accordance with DNV 2007: Sec. 5; P.46)
Elastic collapse pressure (Pel) Mpa 6.186 7.133 7.115 11.870
Plastic collapse pressure (Pp) Mpa 20.210 21.192 21.175 25.113
Maximum fabrication factor (afab: for seamless) 1.00 1.00 1.00 1.00
Ovality ( fo) 0.015 0.015 0.015 0.015
Collapse pressure ( Pc) = y-1/3*b Mpa 5.329 6.110 6.117 9.825
Parameter b = -Pel -6.186 -7.133 -7.115 -11.870
Parameter c = -( PP^2+ Pp*Pel*f0*(D/t)) -468.437 -516.844 -514.305 -740.688
Parameter d = Pel *Pp^2 2,526.555 3203.169 3,190.134 7,486.092
Parameter u = (1/3)*((-1/3)*b^2 +c) -160.397 -177.934 -177.060 -262.551
PRESSURE CONTAINMENT (BURSTING) (Check in accordance with DNV 2007: Sec. 5; P.46)
Pressure containment resistance (Pb) Mpa 26.977 26.873 29.583 29.932
Incidental pressure ( Pinc) Mpa 12.100 12.100 12.100 12.100
Local incidental pressure (Pli) Mpa 12.212 12.212 12.212 12.212
Elevation of the reference point ( href) m 20.000 20.000 20.000 20.000
PIPELINE MATERIAL DATA D=16" D= 14" D=12" D=10"
Elevation of the locol pressure point (hl)(positive
upwards) m -59.300 -59.300 -59.300 -59.300
Content density kg/m3 144.500 144.500 144.500 144.500
External pressure( Pe) Mpa 0.596 0.596 0.596 0.596
Yeild stress (fy) Mpa 423.360 423.360 423.360 423.360
Tensile strength (fu) Mpa 503.040 503.040 503.040 503.040
fcb = Min[fy;(fu/1.15)] 423.360 423.360 423.360 423.360
Material resistance factor (ym) 1.150 1.150 1.150 1.150
Safety class resistance factor (ysc) 1.308 1.308 1.308 1.308
De-rating values due to temperature of yeild
stress (fy.tem) Mpa 7.00 7.00 7.00 7.00
De-rating values due to temperature of tensile
strength (fu.tem) Mpa 7.00 7.00 7.00 7.00
Minimum wall thickness (t1) mm 10.913 9.513 9.513 8.113
Wall thickness withoat tcor(t2) mm 12.900 11.300 11.300 9.700
Fabrication thickness tolerance mm 1.988 1.788 1.788 1.588
Material strenght factor (au) 0.96 0.96 0.96 0.96
Maximum fabrication factor (afab: for seamless) 1.000 1.000 1.000 1.000
Ovality ( fo) 0.015 0.015 0.015 0.015
Collapse pressure ( Pc) = y-1/3*b Mpa 11.575 11.666 14.864 15.657
Parameter b = -Pel -14.550 -14.599 -19.318 -20.385
Parameter c = -( PP^2+ Pp*Pel*f0*(D/t)) -872.287 -870.473 -1066.480 -1102.186
Parameter d = Pel *Pp^2 10510.385 10568.711 16856.836 18436.936
Parameter u = (1/3)*((-1/3)*b^2 +c) -314.285 -313.837 -396.958 -413.567
Specified Minimum Yield Stress (SYMS) [5] Mpa 414.00 414.00 414.00 414.00
Specified Minimum Tensile Strength (SMTS)
[5] Mpa 517.00 517.00 517.00 517.00
Poisson's ratio(ν) 0.30 0.30 0.30 0.30
Water density kg/m^3 1,025.00 1025.000 1,025.00 1,025.00
Gravity acceleration (g) m/c^2 9.81 9.810 9.81 9.81
Maximum water depth m 48.50 48.50 48.50 48.50
Calculated Wall thickness (tcal) for Zone 1 mm 9.82 8.96 8.43 7.58
Selected Wall thickness (t) for Zone 1 mm 12.70 12.70 12.70 11.10
HOOP STRESS ( Check in with [1])
Internal Pressure (Pi) Mpa 10.00 10.00 10.00 10.00
Hoop stress (Sh) Mpa 152.20 133.17 121.30 117.02
Allowable Hoop stress Mpa 298.08 298.08 298.08 298.08
Check with formula: Sh< allowable hoop
stress PASS PASS PASS PASS
APPENDIX 2
ZONE 2
Design factor (F for Zone 2) 0.50 0.50 0.50 0.50
Calculeted Wall thickness (tcal) mm 12.816 11.589 10.824 9.597
Selected Wall thickness (tcal) mm 15.90 15.90 12.70 12.70
PROPAGATION BUCKLING
Propagating pressure (Ppr) 2.455 3.428 2.122 3.251
Check with formula: Pe<(Ppr/ym*ysc) PASS PASS PASS PASS
IN CASE:
MAOP = 100 Barg
Pdesign = 110 Barg
Line pipe Material: API Grade X60
Units Value
Input Parameters
PRESSURE CONTAINMENT (BURSTING) (Check in accordance with DNV 2007: Sec. 5; P.46)
Pressure containment resistance (Pb) Mpa 18.38 21.066 19.10
Incidental pressure ( Pinc) Mpa 12.10 12.10 12.10
Local incidental pressure (Pli) Mpa 12.236 12.236 12.236
Elevation of the reference point ( href) m 20.00 20.00 20.00
Elevation of the local pressure point (hl)(positive
upwards) m -59.30 -59.30 -59.30
Content density kg/m3 175.20 175.20 175.20
External pressure( Pe) Mpa 0.596 0.596 0.596
Yeild stress (fy) Mpa 390.72 390.72 390.72
Tensile strength (fu) Mpa 489.60 489.60 489.60
fcb = Min[fy;(fu/1.15)] 390.72 390.72 390.72
Material resistance factor (ym) 1.15 1.15 1.15
Safety class resistance factor (ysc) 1.308 1.308 1.308
De-rating values due to temperature of yeild stress
(fy.tem) Mpa 7.00 7.00 7.00
De-rating values due to temperature of tensile
strength (fu.tem) Mpa 7.00 7.00 7.00
Minimum wall thickness (t1) mm 8.11 8.11 6.71
Wall thickness withoat tcor(t2) mm 9.70 9.70 8.10
Fabrication thickness tolerance mm 1.588 1.588 1.388
Material strenght factor (au) 0.960 0.960 0.960
Check with formula (Pli-Pe)<=(Pb/ym.ysc) PASS PASS PASS
LOCAL BUCKLING ( SYSTEM COLLAPSE)(Check in accordance with DNV 2007: Sec. 5; P.46)
ZONE 2
Design factor (F for Zone 2) 0.50 0.50 0.50
Calculeted Wall thickness (tcal) mm 13.798 12.448 11.606
Selected Wall thickness (tcal) mm 15.90 15.90 14.30
PRESSURE CONTAINMENT (BURSTING) (Check in accordance with DNV 2007: Sec. 5; P.46)
Pressure containment resistance (Pb) Mpa 24.898 28.567 27.302
Incidental pressure ( Pinc) Mpa 12.100 12.100 12.100
Local incidental pressure (Pli) Mpa 12.236 12.236 12.236
Elevation of the reference point ( href) m 20.000 20.000 20.000
Elevation of the locol pressure point (hl)(positive
upwards) m -59.300 -59.300 -59.300
Content density kg/m3 175.200 175.200 175.200
External pressure( Pe) Mpa 0.596 0.596 0.596
Yeild stress (fy) Mpa 390.720 390.720 390.720
Tensile strength (fu) Mpa 489.600 489.600 489.600
fcb = Min[fy;(fu/1.15)] 390.720 390.720 390.720
Material resistance factor (ym) 1.150 1.150 1.150
Safety class resistance factor (ysc) 1.308 1.308 1.308
De-rating values due to temperature of yeild stress
(fy.tem) Mpa 7.00 7.00 7.00
De-rating values due to temperature of tensile
strength (fu.tem) Mpa 7.00 7.00 7.00
Minimum wall thickness (t1) mm 10.913 10.913 9.513
Wall thickness withoat tcor(t2) mm 12.900 12.900 11.300
Fabrication thickness tolerance mm 1.988 1.988 1.788
Material strenght factor (au) 0.96 0.96 0.96
Check with formula (Pli-Pe)<=(Pb/ym.ysc) PASS PASS PASS
LOCAL BUCKLING ( SYSTEM COLLAPSE)(Check in accordance with DNV 2007: Sec. 5; P.46)
Elastic collapse pressure (Pel) Mpa 14.550 21.719 19.318
Plastic collapse pressure (Pp) Mpa 23.068 26.364 25.354
609
D=10"
207,000.00
414.00
517.00
0.30
1,025.00
9.81
59.30
11.00
20.70
60.00
3.00
1.00
273.10
1.00
0.72
8.04
11.10
11.00
127.98
298.08
PASS
22.74
12.10
12.236
20.00
-59.30
175.20
0.596
390.72
489.60
390.72
1.15
1.308
7.00
7.00
6.71
8.10
1.388
0.960
PASS
11.870
21.555
0.93
0.015
9.466
-11.870
-559.029
5,514.837
-201.998
1,589.537
2.158
5.509
1.927
PASS
0.50
10.256
12.70
111.861
207.00
PASS
46)
27.624
12.100
12.236
20.000
-59.300
175.200
0.596
390.720
489.600
390.720
1.150
1.308
7.00
7.00
8.113
9.700
1.588
0.96
PASS
46)
20.385
25.812
0.930
0.015
14.763
-20.385
-836.006
13582.080
-324.840
3636.985
2.241
7.968
3.024
PASS
IN CASE:
MAOP = 100 Barg
Pdesign = 110 Barg
Line pipe Material: API Grade X65
Units Value
Input Parameters
PRESSURE CONTAINMENT (BURSTING) (Check in accordance with DNV 2007: Sec. 5; P.46)
Pressure containment resistance (Pb) Mpa 19.91 18.811 20.69
Incidental pressure ( Pinc) Mpa 12.10 12.10 12.10
Local incidental pressure (Pli) Mpa 12.236 12.236 12.236
Elevation of the reference point ( href) m 20.00 20.00 20.00
Elevation of the local pressure point (hl)(positive
upwards) m -59.30 -59.30 -59.30
Content density kg/m3 175.20 175.20 175.20
External pressure( Pe) Mpa 0.596 0.596 0.596
Yeild stress (fy) Mpa 423.36 423.36 423.36
Tensile strength (fu) Mpa 503.04 503.04 503.04
fcb = Min[fy;(fu/1.15)] 423.36 423.36 423.36
Material resistance factor (ym) 1.15 1.15 1.15
Safety class resistance factor (ysc) 1.308 1.308 1.308
De-rating values due to temperature of yeild stress
(fy.tem) Mpa 7.00 7.00 7.00
De-rating values due to temperature of tensile
strength (fu.tem) Mpa 7.00 7.00 7.00
Minimum wall thickness (t1) mm 8.11 6.71 6.71
Wall thickness withoat tcor(t2) mm 9.70 8.10 8.10
Fabrication thickness tolerance mm 1.588 1.388 1.388
Material strenght factor (au) 0.960 0.960 0.960
Check with formula (Pli-Pe)<=(Pb/ym.ysc) PASS PASS PASS
LOCAL BUCKLING ( SYSTEM COLLAPSE)(Check in accordance with DNV 2007: Sec. 5; P.46)
ZONE 2
Design factor (F for Zone 2) 0.50 0.50 0.50
Calculeted Wall thickness (tcal) mm 12.979 11.731 10.953
Selected Wall thickness (tcal) mm 15.900 14.300 14.300
PRESSURE CONTAINMENT (BURSTING) (Check in accordance with DNV 2007: Sec. 5; P.46)
Pressure containment resistance (Pb) Mpa 26.977 26.873 29.583
Incidental pressure ( Pinc) Mpa 12.100 12.100 12.100
Local incidental pressure (Pli) Mpa 12.236 12.236 12.236
Elevation of the reference point ( href) m 20.000 20.000 20.000
Elevation of the locol pressure point (hl)(positive
upwards) m -59.300 -59.300 -59.300
Content density kg/m3 175.200 175.200 175.200
External pressure( Pe) Mpa 0.596 0.596 0.596
Yeild stress (fy) Mpa 423.360 423.360 423.360
Tensile strength (fu) Mpa 503.040 503.040 503.040
fcb = Min[fy;(fu/1.15)] 423.360 423.360 423.360
Material resistance factor (ym) 1.150 1.150 1.150
Safety class resistance factor (ysc) 1.308 1.308 1.308
De-rating values due to temperature of yeild stress
(fy.tem) Mpa 7.00 7.00 7.00
De-rating values due to temperature of tensile
strength (fu.tem) Mpa 7.00 7.00 7.00
Minimum wall thickness (t1) mm 10.913 9.513 9.513
Wall thickness withoat tcor(t2) mm 12.900 11.300 11.300
Fabrication thickness tolerance mm 1.988 1.788 1.788
Material strenght factor (au) 0.96 0.96 0.96
Check with formula (Pli-Pe)<=(Pb/ym.ysc) PASS PASS PASS
LOCAL BUCKLING ( SYSTEM COLLAPSE)(Check in accordance with DNV 2007: Sec. 5; P.46)
Elastic collapse pressure (Pel) Mpa 14.550 14.599 19.318
Plastic collapse pressure (Pp) Mpa 26.877 26.906 29.540
Maximum fabrication factor (afab: for seamless) 1.000 1.000 1.000
Ovality ( fo) 0.015 0.015 0.015
Collapse pressure ( Pc) = y-1/3*b Mpa 11.575 11.666 14.864
Parameter b = -Pel -14.550 -14.599 -19.318
Parameter c = -( PP^2+ Pp*Pel*f0*(D/t)) -872.287 -870.473 -1066.480
Parameter d = Pel *Pp^2 10510.385 10568.711 16856.836
Parameter u = (1/3)*((-1/3)*b^2 +c) -314.285 -313.837 -396.958
609
D=10"
207,000.00
448.00
531.00
0.30
1,025.00
9.81
59.30
11.00
20.70
60.00
3.00
1.00
273.10
1.00
0.72
7.66
11.10
11.00
127.98
322.56
PASS
24.64
12.10
12.236
20.00
-59.30
175.20
0.596
423.36
503.04
423.36
1.15
1.308
7.00
7.00
6.71
8.10
1.388
0.960
PASS
11.870
25.113
1.00
0.015
9.825
-11.870
-740.688
7,486.092
-262.551
2,215.782
2.119
5.868
2.245
PASS
0.50
9.706
12.700
111.861
224.00
PASS
46)
29.932
12.100
12.236
20.000
-59.300
175.200
0.596
423.360
503.040
423.360
1.150
1.308
7.00
7.00
8.113
9.700
1.588
0.96
PASS
46)
20.385
30.074
1.000
0.015
15.657
-20.385
-1102.186
18436.936
-413.567
5160.070
2.231
8.862
3.523
PASS
IN CASE:
Units Value
Input Parameters
PRESSURE CONTAINMENT (BURSTING) (Check in accordance with DNV 2007: Sec. 5; P.46)
Pressure containment resistance (Pb) Mpa 23.43 26.873 25.12
Incidental pressure ( Pinc) Mpa 15.40 15.40 15.40
Local incidental pressure (Pli) Mpa 15.536 15.536 15.536
Elevation of the reference point ( href) m 20.00 20.00 20.00
Elevation of the local pressure point (hl)(positive
upwards) m -59.30 -59.30 -59.30
Content density kg/m3 175.20 175.20 175.20
External pressure( Pe) Mpa 0.596 0.596 0.596
Yeild stress (fy) Mpa 423.36 423.36 423.36
Tensile strength (fu) Mpa 503.04 503.04 503.04
fcb = Min[fy;(fu/1.15)] 423.36 423.36 423.36
Material resistance factor (ym) 1.15 1.15 1.15
Safety class resistance factor (ysc) 1.308 1.308 1.308
De-rating values due to temperature of yeild stress
(fy.tem) Mpa 7.00 7.00 7.00
De-rating values due to temperature of tensile
strength (fu.tem) Mpa 7.00 7.00 7.00
Minimum wall thickness (t1) mm 9.51 9.51 8.11
Wall thickness withoat tcor(t2) mm 11.30 11.30 9.70
Fabrication thickness tolerance mm 1.788 1.788 1.588
Material strenght factor (au) 0.960 0.960 0.960
Check with formula (Pli-Pe)<=(Pb/ym.ysc) PASS PASS PASS
LOCAL BUCKLING ( SYSTEM COLLAPSE)(Check in accordance with DNV 2007: Sec. 5; P.46)
ZONE 2
Design factor (F for Zone 2) 0.50 0.50 0.50
Calculeted Wall thickness (tcal) mm 15.700 14.113 13.122
Selected Wall thickness (tcal) mm 17.800 15.900 14.300
PRESSURE CONTAINMENT (BURSTING) (Check in accordance with DNV 2007: Sec. 5; P.46)
Pressure containment resistance (Pb) Mpa 31.219 30.953 29.583
Incidental pressure ( Pinc) Mpa 15.400 15.400 15.400
Local incidental pressure (Pli) Mpa 15.536 15.536 15.536
Elevation of the reference point ( href) m 20.000 20.000 20.000
Elevation of the locol pressure point (hl)(positive
upwards) m -59.300 -59.300 -59.300
Content density kg/m3 175.200 175.200 175.200
External pressure( Pe) Mpa 0.596 0.596 0.596
Yeild stress (fy) Mpa 423.360 423.360 423.360
Tensile strength (fu) Mpa 503.040 503.040 503.040
fcb = Min[fy;(fu/1.15)] 423.360 423.360 423.360
Material resistance factor (ym) 1.150 1.150 1.150
Safety class resistance factor (ysc) 1.308 1.308 1.308
De-rating values due to temperature of yeild stress
(fy.tem) Mpa 7.00 7.00 7.00
De-rating values due to temperature of tensile
strength (fu.tem) Mpa 7.00 7.00 7.00
Minimum wall thickness (t1) mm 12.575 10.913 9.513
Wall thickness withoat tcor(t2) mm 14.800 12.900 11.300
Fabrication thickness tolerance mm 2.225 1.988 1.788
Material strenght factor (au) 0.96 0.96 0.96
Check with formula (Pli-Pe)<=(Pb/ym.ysc) PASS PASS PASS
LOCAL BUCKLING ( SYSTEM COLLAPSE)(Check in accordance with DNV 2007: Sec. 5; P.46)
Elastic collapse pressure (Pel) Mpa 21.973 21.719 19.318
Plastic collapse pressure (Pp) Mpa 30.835 30.716 29.540
Maximum fabrication factor (afab: for seamless) 1.000 1.000 1.000
Ovality ( fo) 0.015 0.015 0.015
Collapse pressure ( Pc) = y-1/3*b Mpa 16.373 16.301 14.864
Parameter b = -Pel -21.973 -21.719 -19.318
Parameter c = -( PP^2+ Pp*Pel*f0*(D/t)) -1182.850 -1167.290 -1066.480
Parameter d = Pel *Pp^2 20891.935 20491.718 16856.836
Parameter u = (1/3)*((-1/3)*b^2 +c) -447.928 -441.510 -396.958
609
D=10"
207,000.00
448.00
531.00
0.30
1,025.00
9.81
59.30
14.00
20.70
60.00
3.00
1.00
273.10
1.00
0.72
8.93
12.70
14.00
144.12
322.56
PASS
29.93
15.40
15.536
20.00
-59.30
175.20
0.596
423.36
503.04
423.36
1.15
1.308
7.00
7.00
8.11
9.70
1.588
0.960
PASS
20.385
30.074
1.00
0.015
15.657
-20.385
-1,102.186
18,436.936
-413.567
5,160.070
2.231
8.862
3.523
PASS
0.50
11.534
14.300
127.992
224.00
PASS
46)
35.284
15.400
15.536
20.000
-59.300
175.200
0.596
423.360
503.040
423.360
1.150
1.308
7.00
7.00
9.513
11.300
1.788
0.96
PASS
46)
32.228
35.035
1.000
0.015
22.298
-32.228
-1550.866
39556.905
-632.358
10208.591
2.268
11.555
5.160
PASS