Stationary Power Generation - Accessories Price List Series 2000 G05

12V 2000 G25/G65


12V 2000 G45/G85
16V 2000 G25/G65
16V 2000 G45/G85
Delivery mode

18V 2000 G65


18V 2000 G85
Pos.
Item Description Remarks
G00.10 BASIC ENGINE CONFIGURATION
with electronic engine management system, see Scope of Supply / Price List
G00.10c manufacture MTU, ADEC "Basic Engine Configuration"
G00.10a - fuel consumption-optimized engine version l - l - l - 12V also avaible for India ARAI
G00.10d - exhaust emission-optimized engine version, - l - l - l
without label (acc. to EPA 40 CFR 89 / Tier 2)

G00.22a Special applications


G00.22 - UPS (Uninterrupted Power Supply)       on request, only in conjunction with item
G03.60

G00.50f Optimizations
G00.50 Exhaust emission optimization without test  - - - - - only for 1500 rpm, 3B,
G00.50a measurement results (acc. to TA-Luft regu- - -  - - - only air charge air cooling
G00.50b lations, NOx < 1500 mg/m³ i.N.) - - - -  -

G00.51 Exhaust emission optimization with test  - - - - - only for 1500 rpm, 3B,
G00.51a measurement results and protocol (acc. to - -  - - - only air charge air cooling
G00.51b TA-Luft regulations, NOx < 1500 mg/m³ i.N.) - - - -  -

G00.62 Exhaust emission optimization with certification -  - - - - only for 1800 rpm, necessary for
G00.62a label on engine (acc. to EPA 40 CFR 60 Tier 2 - - -  - - use in USA and Canada
G00.62b Stationary Emergency, EPA 40 CFR 89 Tier 2 compliant - - - - - 
or flexibility)

G00.19 Exhaust emissions ARAI-Indien (2004), Stage I  - - - - - for Indian Market only
G00.19a (valid until 30.06.2014) with label

G00.80 Engine standard factory acceptance testing l l l l l l


(w/o customer participation)

G00.90 Engine internal preservation l l l l l l

G01.00 Starting System and Auxiliary Power Supply


G01.10 M Electric starter l l l l l l

G01.40 M Compressed air starter with electric   - - - - in place of item G01.10


G01.40a starting valve (24 VDC, max. 30 bar) - -    

G01.50 M Redundant starting system, consisting of: in place of item G01.10


G01.50a 2 electric starters   - - - -
G01.50b - -    

G01.51 M Electric starter and compressed air starter with   - - - - in place of item G01.10
G01.51a electric starting valve (24 VDC, max. 30 bar) - -    

G01.57 M Parallel starting system, consisting of: - -     in place of item G01.10


G01.57a 2 electric starters

G01.90 M Battery charging alternator, V-belt driven      

G01.92 M Battery charging alternator, V-belt driven       in place of item G01.90

G02.00 Fuel System


G02.10 M Main fuel filter (without diverter valve) l l l l l l

G02.20 S Fuel pre-filter with connecting parts for      


installation before low pressure fuel pump

G02.30 S Special fuel pre-filter, selectable with       in place of item G02.20


water separator and water-level sensor

OSO 07 461 (52 3E) 1/14 6


MTU Friedrichshafen GmbH
Stationary Power Generation - Accessories Price List Series 2000 G05

12V 2000 G25/G65


12V 2000 G45/G85
16V 2000 G25/G65
16V 2000 G45/G85
Delivery mode

18V 2000 G65


18V 2000 G85
Pos.
Item Description Remarks
G03.00 Lube Oil System
G03.10 M Oil filler neck, dipstick for measurement l l l l l l
on non-running engine

G03.20 M Lube oil multi-stage filter, without diverter valve l l l l l l

G03.25 M Closed crankcase breather system l l l l l l

G03.26 M Open crankcase without return to combustion air system       in place of item G03.25

G03.40 S Hand pump for lube oil extraction      

G03.60 Electrical interval pre-lubrication pump


G03.60a S (400 VAC / 3 ph / 50 Hz / 0,75 kW)  -  -  -
G03.60b S (440 VAC / 3 ph / 60 Hz / 0,75 kW) -  -  - 

G03.61 S Set of connecting parts for interval pre-lubrication pump       contained in item G03.60, in case of
customer supplied pre-lubrication pump

G04.00 Combustion Air System


G04.10 S Set of dry-type air filters with contamination indicator l l l l l l
and mounting parts (air intake vertical)

G04.11 S Set of dry-type air filters with pre-separator,   - - - - for medium to heavy duty use
G04.11a safety element, contamination indicator, - -     in place of item G04.10
G04.11b rain cap and mounting parts

G05.00 Exhaust System


G05.10 S Set of bellows (2x) with gaskets and companion      
flanges for connection to exhaust elbow

G05.11 S Set of companion flanges (2x) with gaskets for       in place of item G05.10
connection to exhaust elbow

G06.00 Cooling System (air charge air cooling)


G06.10 S Set of connecting parts for charge air l l l l l l
(Charge air piping)

G06.61 S Radiator-Cooler with mechanically driven fan l l l l l l


for engines with air charge air cooling
including connection parts for engine coolant
circuit designed for 100% 3D or 110% 3A/3B
engine power (except 18V 60 Hz 3B and 50 Hz
TA-Luft designed for 100%), backpressure 200 Pa,
40 °C / 104 °F ambient air temperature

G06.62 S Radiator-Cooler with mechanically driven fan  - - - - - RK: size 3.1


G06.62a for engines with air charge air cooling including - -  - - - RK: size 3.2
G06.62b connection parts for engine coolant circuit - - - -  - RK: size 3.3
G06.62c designed for 100 % 3D or 110% 3A/3B engine -  - - - - RK: size 4.1
G06.62d power (except 18V 60 Hz 3B designed for 100%), - - -  - - RK: size 4.2
G06.62e backpressure 200 Pa 50 °C / 122 °F ambient - - - - -  RK: size 4.3 for 18V 3B
G06.62f air temperature - - - - -  RK: size 4.4 for 18V 3D
G06.62g In place of item G06.61 (not for TA-Luft)

G06.63 S Radiator-Cooler with mechanically driven fan   - - - - RK: size 1.7/1.8/2.5/3.4/4.5/5.7/5.8/6.5


for engines with air charge air cooling in place of item G06.61/G06.62/G06.69
including connection parts for engine coolant circuit
designed for 100% 3D and 110% 3A/3B engine
power (except 50 Hz TA-Luft designed for 100%),
with optimized fan power, backpressure 200 Pa,
40 °C / 104 °F ambient air temperature

OSO 07 461 (52 3E) 1/14 7


MTU Friedrichshafen GmbH
Stationary Power Generation - Accessories Price List Series 2000 G05

12V 2000 G25/G65


12V 2000 G45/G85
16V 2000 G25/G65
16V 2000 G45/G85
Delivery mode

18V 2000 G65


18V 2000 G85
Pos.
Item Description Remarks
G06.69 S Radiator-Cooler with mechanically driven fan  - - - - - RK: size 5.1/5.2
G06.69a for engines with air charge air cooling including -  - - - - RK: size 6.1
G06.69b connection parts for engine coolant circuit - -  - - - RK: size 5.3/5.4
G06.69c designed for 100% 3D or 110% 3A/3B engine - - -  - - RK: size 6.2
G06.69d power (except 18V 60 Hz 3B and 50 Hz TA-Luft - - - -  RK: size 5.5/5.6
G06.69e designed for 100%), backpressure 300 Pa, - - - - -  RK: size 6.3
G06.69f 40 °C / 104 °F ambient air temperature - - - - -  RK: size 6.4
G06.69g in place of item G06.61

G06.01 Cooling System (water charge air cooling)


G06.30 M V-belt fan drive without belt tensioner, without fan in place of item G06.61

G06.30a fan speed 1500 rpm  -  - - -


G06.30b fan speed 1800 rpm -  -  - -

G06.31 M V-belt fan drive, with belt tensioner, in place of item G06.30
without fan, selective fan speed:

G06.31a 945, 1005, 1140, 1200 or 1290 rpm  -  -  -


G06.31b 1134, 1206, 1368, 1440 or 1548 rpm -  -  - 

G06.40 M Radiator-Cooler with electric driven fan for separate       on request


installation, consisting of:
- two-circuit cooler
- with expansion tank
- fan
- safety cover for fan drive
- stone guard at cooler air outlet
- fan drive motor:
at 50 Hz: 380 - 415 V, 3 Ph, IP 55
at 60 Hz: 440 - 480 V, 3 Ph, IP 55

G06.02 Cooling System (coolant preheating)


G06.70 S Set of connecting parts for preheating unit on-engine      

G06.72 S Electric coolant preheating unit with circulating


pump, non-return flap and thermostat
G06.72a (230 V / 1 ph / 50 Hz / 3 kW)  -  - - -
G06.72b (254 V / 1 ph / 60 Hz / 3 kW) -  -  - -

G06.73 S Electric coolant preheating unit with circulating


pump, non-return flap and thermostat
G06.73a (400 VAC / 3 ph / 50 Hz / 6,75 kW)  -  -  -
G06.73b (440 VAC / 3 ph / 60 Hz / 9 kW) -  -  - 

G06.74 S Electric coolant preheating unit with circulating


pump, non-return flap and thermostat
G06.74a (400 VAC / 3 ph / 50 Hz / 9 kW)  -  -  -
G06.74b (440 VAC / 3 ph / 60 Hz / 12 kW) -  -  - 

G07.04 Resilient Engine and Alternator Mounting


G07.30 M Engine mounting brackets for resilient mount
G07.30a on engine free end and driving end l l l l l l

G07.32 S Resilient engine mounts (Rubber Elements)       4 pcs.


on engine free end and driving end

G07.34 S Resilient alternator mounting elements       2 pcs.


(Rubber Elements)

G07.35 S Resilient alternator mounting elements       4 pcs., in place of item G07.34


(Rubber Elements)

OSO 07 461 (52 3E) 1/14 8


MTU Friedrichshafen GmbH
Stationary Power Generation - Accessories Price List Series 2000 G05

12V 2000 G25/G65


12V 2000 G45/G85
16V 2000 G25/G65
16V 2000 G45/G85
Delivery mode

18V 2000 G65


18V 2000 G85
Pos.
Item Description Remarks
G07.02 Rigid Engine Mounting (with flange-mounted
alternator B5/B20 or B16)
G07.50 M Engine mounting brackets for rigid mounting on engine       in place of item G07.30
free end and driving end

G09.00 Engine Management


G09.10 Electronic "Speed governor", manufacture MTU, l l l l l l
ADEC, Power supply 24 VDC

G09.11 Speed setting, binary inputs for Up-/Down-triggering l l l l l l

G09.12 Speed setting, analog (0 - 10 VDC) in place of item G09.11


G09.12a Speed setting range 1400 - 1600 rpm (50 Hz)  -  -  -
G09.12b Speed setting range 1700 - 1900 rpm (60 Hz) -  -  - 

G09.13 Speed setting, analog (0 - 5 VDC) in place of item G09.11


G09.13a Speed setting range 1400 - 1600 rpm (50 Hz)  -  -  -
G09.13b Speed setting range 1700 - 1900 rpm (60 Hz) -  -  - 

G09.14 Speed setting, analog (4 - 20 mA) in place of item G09.11


G09.14a Speed setting range 1400 - 1600 rpm (50 Hz)  -  -  -
G09.14b Speed setting range 1700 - 1900 rpm (60 Hz) -  -  - 

G09.15 Selectable droop l l l l l l


Droop setting 1: 4 %
Droop setting 2: 0 %

G09.16 Selectable droop       in place of item G09.15


Droop setting 1: ... %
Droop setting 2: ... %

G09.19 Speed setting by CAN analog       only in conjunction with G10.22

G09.21 Speed setting by CAN up/down       only in conjunction with G10.22

G09.00c Governor configuration for speed governor


G09.30 ADEC governor control response engine l l l l l l
shut-down in case of sensor malfunction

G09.31 ADEC governor control response no engine       in place of item G09.30


shut-down in case of sensor malfunction

G09.00d Cable sets for speed governor


G09.40a Set of cables, W 005 (for ADEC power supply)
and W 001 (interface cable)
G09.40 S - length 10 m l l l l l l
G09.41 S - length 15 m       in place of item G09.40
G09.42 S - length 25 m       in place of item G09.40

OSO 07 461 (52 3E) 1/14 9


MTU Friedrichshafen GmbH
Stationary Power Generation - Accessories Price List Series 2000 G05

12V 2000 G25/G65


12V 2000 G45/G85
16V 2000 G25/G65
16V 2000 G45/G85
Delivery mode

18V 2000 G65


18V 2000 G85
Pos.
Item Description Remarks
G10.00 Monitoring, Displays
G10.01 Service Application Module (SAM), suitable for
installation in switchgear cabinet, service voltage
24 VDC, data communication with ADEC via CAN-Bus

G10.19 S SAM - Advanced l l l l l l


with extensive customer interface (e.g. warnings,
alarms, operating signals and fault codes), redun-
dant data storage, possibility for webserver access,
remote control, life data storage, level indicator for
day and storage tank with limit configuration, fuel
pump control, fan resp. louver control, generator
excitation control, monitoring of generator winding
temperature (L1, L2, L3), preheating control, circu-
lation pump control, load step control, speed and
load-transfer control, monitoring of fuel pre-filter
(single and double) and selection of a second PID
governor data record

G10.22 S Bus card (CCB 2) for connection to a non MTU-Controller      


via CANOPEN / SAE J1939.
Note: Communication between engine and controller
must be certified by MTU

G10.30 S DISPLAY DIS10 - LCD monitor      


Monitoring of relevant operating values and alarms

G10.31 S Lube oil temperature gauge,       DC/DC-transformer necessary see item


round version (52 mm diameter) G10.35

G10.32 S Engine speed gauge,       DC/DC-transformer necessary see item


round version (85 mm diameter) G10.35

G10.33 S Lube oil pressure gauge,       DC/DC-transformer necessary see item


round version (52 mm diameter) G10.35

G10.34 S Coolant temperature gauge,       DC/DC-transformer necessary see item


round version (52 mm diameter) G10.35

G10.35 S DC/DC transformer for maximum 8 gauges,      


for power supply

G10.37 S Engine speed gauge, round version, J1939      

G10.38 S Lube oil pressure gauge, round version, J1939      

G10.39 S Coolant temperature gauge, round version, J1939      

G10.40 S 1 coolant level sensor with cable (5 m) l l l l l l air charge air cooling
G10.40a (Bedia sensor, magnetic-inductive)       water charge air cooling
for installation in coolant circuit expansion tank

G10.41 S 1 coolant level sensor with cable (15 m)       water charge air cooling
(Bedia sensor, magnetic-inductive)
for installation in coolant circuit expansion tank

G10.42 S 1 coolant level sensor with cable (25 m)       water charge air cooling
(Bedia sensor, magnetic-inductive)
for installation in coolant circuit expansion tank

OSO 07 461 (52 3E) 1/14 10


MTU Friedrichshafen GmbH
Stationary Power Generation - Accessories Price List Series 2000 G05

12V 2000 G25/G65


12V 2000 G45/G85
16V 2000 G25/G65
16V 2000 G45/G85
Delivery mode

18V 2000 G65


18V 2000 G85
Pos.
Item Description Remarks
G15.00 Painting
G15.30 Standard paintwork, single-coat, water-based paint l l l l l l
brilliant blue, RAL 5007

G15.32 Special paintwork, two-component hydro paint   - - - - in place of item G15.30


G15.32a arrangement - -   - - special coloring on request
G15.32b (not available for stock engines) - - - -  

G15.39 Primer (not available for stock engines)       in place of item G15.30

G16.00 Documentation
G16.10 S Set of standard documentation (Hardcopy German) l l l l l l
consisting of:
- Installation instruction
- Fuel regulations
- Operating instructions

Set of standard documentation (CD-ROM) consisting of:


- Fuel regulations
- Operating instructions
- Functional descript
- Tool catalogue

G16.20 S Set of standard documentation (Hardcopy English) l l l l l l in place of item G16.10


consisting of:
- Installation instruction
- Fuel regulations
- Operating instructions

Set of standard documentation (CD-ROM) consisting of:


- Fuel regulations
- Operating instructions
- Functional descript
- Tool catalogue

G16.11 S Additional set of standard documentation (Hardcopy      


German) consisting of:
- Installation instruction
- Fuel regulations
- Operating instructions
- Functional descript
- Tool catalogue

G16.21 S Additional set of standard documentation (Hardcopy      


English) consisting of:
- Installation instruction
- Fuel regulations
- Operating instructions
- Functional descript
- Tool catalogue

G16.15 S Additional set of standard documentation (CD-ROM)      


consisting of:
- Fuel regulations
- Operating instructions
- Functional descript
- Tool catalogue

OSO 07 461 (52 3E) 1/14 11


MTU Friedrichshafen GmbH
Stationary Power Generation - Accessories Price List Series 2000 G05

12V 2000 G25/G65


12V 2000 G45/G85
16V 2000 G25/G65
16V 2000 G45/G85
Delivery mode

18V 2000 G65


18V 2000 G85
Pos.
Item Description Remarks
G16.25 S Additional set of standard documentation (CD-ROM      
English) consisting of:
- Fuel regulations
- Operating instructions
- Functional descript
- Tool catalogue

G17.00 Technical Calculations


G17.10 Torsional vibration calculation with report       only 1x for all identical
(for standard-configuration units) units per order

G17.11 Torsional vibration calculation with report       on request


(for special-configuration plant e.g. UPS gensets) only 1x for all identical
units per order
(1x per system)

G17.15 Calculation for the layout of the exhaust / cooling /       only 1x for all identical
fuel piping system (for standard design) designs per order
(1x per system)

G17.16 Calculation for the layout of the exhaust / cooling /       on request


fuel piping system (for special design) only 1x for all identical
designs per order
(1x per system)

G18.00 Packing
G18.10 Container-transportation cradle for engine in l l l l l l
G18.10a PVC cover and crate for accessories

G19.00 Additional Supplies


G19.10 Attendance of customer representative during      
engine standard factory acceptance testing

G19.20 Engine training for customers       on request


details see training program

G19.60 Delivery condition FCA manufacturer facility (Incoterms l l l l l l


2010)

G19.62 Delivery condition CIP (Incoterms 2010)       on request

G19.01 Laboratory Services

G19.30 Fluids and lubricants analyses (engine oils, engine       on request


coolants and diesel fuels)

G19.40 Metallurgical laboratory services (e.g. material-related       on request


consultancy service, particles analyses)

l included in price for 'Basic Engine Configuration'


G60.01 M engine-mounted  strongly recommended optional equipment
G60.02 S supplied separately  optional equipment
- not available

G60.03 Accessory prices are only valid concurrently with engine order.