OM S70 TunnelDamper 11 2014
OM S70 TunnelDamper 11 2014
Table of Contents
Safety Instructions - Definition of Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.1 Hazard-free use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2 Qualified Personnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Principle Of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Electrical Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Mechanical Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CW vs CCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Elevated Temperature Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Manual Override Operation (Declutchable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Pre-Installation Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Mounting to a Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Field Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Travel Limit Switch and Mechanical Travel Stop Adjustment . . . . . . . . . . . . . . . . . . . . . . . . 5
Clockwise Travel Switch adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Counter-Clockwise Travel Switch adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Typical Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Disassembly and Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Appendix A - Basic Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Appendix B - Actuator Troubleshooting Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Exploded View Series 70 Tunnel Damper Model Housing Size 12 . . . . . . . . . . . . . . . . . . . . . . . 10
Exploded View Series 70 Tunnel Damper Model Housing Size 30 . . . . . . . . . . . . . . . . . . . . . . . 11
1
BRAY Series 70 Tunnel Damper Electric Actuator
Operation and Maintenance Manual
! WARNING
indicates a potentially hazardous situation which, if not avoided, could re-
sult in death or serious injury.
! CAUTION
indicates a potentially hazardous situation which, if not avoided, may result
in minor or moderate injury.
used without the safety alert symbol indicates a potential situation which, if
! NOTICE not avoided, may result in an undesirable result or state, including property
damage.
1.1 HAZARD-FREE USE • Is trained in the proper use and care of personal
protective equipment (PPE) in accordance with
This device left the factory in proper condition to be safely
established safety practices
installed and operated in a hazard-free manner. The notes
• Is trained in first aid
and warnings in this document must be observed by the
• In cases where the device is installed in a potentially
user if this safe condition is to be maintained and hazard-
explosive (hazardous) location – is trained in the
free operation of the device assured.
operation, commissioning, operation and maintenance
of equipment in hazardous locations
Take all necessary precautions to prevent damage to the
actuator due to rough handling, impact, or improper
storage. Do not use abrasive compounds to clean the
actuator, or scrape metal surfaces with any objects.
! WARNING
The control systems in which the actuator is installed must The actuator must only be installed, commissioned,
have proper safeguards to prevent injury to personnel, or operated and repaired by qualified personnel.
damage to equipment, should failure of system components
The device generates large mechanical force during
occur.
normal operation.
All installation, commissioning, operation and
1.2 QUALIFIED PERSONNEL maintenance must be performed under strict observation
A qualified person in terms of this document is one who of all applicable codes, standards and safety regulations.
is familiar with the installation, commissioning and opera-
Reference is specifically made here to observe all
tion of the device and who has appropriate qualifications,
applicable safety regulations for actuators installed in
such as:
potentially explosive (hazardous) locations.
2
BRAY Series 70 Tunnel Damper Electric Actuator
Operation and Maintenance Manual
Part Numbering System Reference chart W - DESIGNATES THE SPEED
2 15/18 seconds
Series Torque Code Speed Product Style Voltage Trim DIR
70 AAA W 113 X Y 536 /Z X - DESIGNATES STYLE
E Basic Unit - Declutchable
Housing Torque Speed, ¼ Turn Supply
Part Number
Size (In.Lbs) (Seconds) (Voltage) Y - DESIGNATES THE VOLTAGE
12 70-0122-113E0-536 1200 15 120 VAC 0 120VAC
12 70-0202-113E0-536 2000 15 120 VAC
/Z - DESIGNATES DIRECTION OF OPEN TRAVEL
30 70-0302-113E0-536 3000 18 120 VAC
30 70-0502-113E0-536 5000 18 120 VAC /CW Clockwise
Use this chart as a guide to interpret the S70 Tunnel Damper electric actuator part number. /CCW Counter-Clockwise
3
BRAY Series 70 Tunnel Damper Electric Actuator
Operation and Maintenance Manual
MANUAL OVERRIDE OPERATION
(DECLUTCHABLE)
The manual override operates similar to a watch adjusting
! NOTICE
knob. To engage the manual override, simply pull the hand- The standard mounting position for the actuator is to
wheel to its outermost position. A yellow stripe is revealed orient the unit with its handwheel in a vertical plane and
for visual indication that the unit cannot run electrically. parallel to the pipeline. If the actuator is to be mounted
The two handwheel positions, engaged and disengaged, on a vertical pipe, it is recommended that the unit be
are held in place with the use of spring plungers. The hand- positioned with the conduit entries on the bottom to
wheel remains in position until physically moved. Rotating prevent condensation from entering the actuator by
the handwheel in the clockwise direction will rotate the way of the conduit. In all cases, the conduit should be
output shaft in the same clockwise direction and vice-versa. positioned to prevent drainage into the actuator.
The actuator should be mounted to the valve as follows:
1. Manually operate the actuator until the output shaft
! CAUTION
of the actuator is in line with the valve stem. If pos-
sible, select an intermediate position (i.e. valve disc/
A label on the handwheel hub warns users not to exceed stem and actuator both half open).
a specific rim pull force, for each size of actuator. If the 2. Place the proper adapter, if required, onto the valve
rim pull force is exceeded, the roll pin securing the hand- stem. It is recommended that a small amount of grease
wheel onto the manual override shaft is designed to shear, be applied to the adapter to ease assembly.
thus preventing more serious internal gearing damage. 3. Mount the actuator onto the valve stem. It may be
necessary to swing or manually override the actuator
to align the bolt patterns.
PRE-INSTALLATION STORAGE
4. Install the furnished mounting studs by threading them
Actuators are not weatherproof until properly installed all the way into the actuator base.
on the valve or prepared for storage. Bray cannot accept 5. Fasten in place with the furnished hex nuts and lock
responsibility for deterioration caused on-site once the washers.
cover is removed.
FIELD WIRING
! NOTICE ! WARNING
Units are shipped with two metal screw-in plugs to pre- Turn off all power and lock out service panel before
vent foreign matter from entering the unit. To prevent installing or modifying any electrical wiring.
condensation from forming inside these units, maintain
a near constant external temperature and store in a well- Each actuator is provided with two (2) conduit entries (one
ventilated, clean, dry room away from vibration. for power and one for control).
Power should be supplied to the heater via conduit entry 1. The motor full load current is noted on the nameplate
and appropriate sealing gland. of the actuator. The terminal strip will accept wire
sizes ranging from 14 to 22 AWG.
Store units on a shelf or wooden pallet in order to protect
against floor dampness.
Keep units covered to protect against dust and dirt. ! NOTICE
18 AWG minimum wire is recommended for all field
INSTALLATION
wiring.
MOUNTING TO A VALVE Note that heaters use approximately 0.5 amps at 110 volts.
All Bray Series 70 electric actuators are suitable for direct 2. All actuators have their applicable wiring diagram
mounting on Bray butterfly valves. With proper mounting attached to the inside of the cover. Field wiring
hardware, the S70 actuator can be installed onto other should be terminated at the actuator terminal strip
quarter-turn valves or devices, such as a damper. in accordance with this wiring diagram.
4
BRAY Series 70 Tunnel Damper Electric Actuator
Operation and Maintenance Manual
Striker Bar
! NOTICE
The conduit connections must be properly sealed to main-
tain the weatherproof integrity of the actuator enclosure.
! CAUTION
Do not reverse motor instantaneously when it is still run-
ning. Reversing direction to actuator motor when it is
running can cause damage to motor, switches and gear- CLOCKWISE TRAVEL SWITCH ADJUSTMENT
ing. Directional control switching can be done by PLC in
1. Loosen the mechanical stop for the CW position and
20ms or by a small relay in 46ms. Therefore time delay
back it off so that it does not interfere with actuator
of 1s has to be incorporated into the control scheme to
travel (CW stop located on right when viewed from
avoid damage.
travel stop side of actuator).
2. Reference the striker bar for damper position.
TRAVEL LIMIT SWITCH AND MECHANICAL
TRAVEL STOP ADJUSTMENT 3. Manually operate the actuator handwheel clockwise
until the valve reaches the desired fully CW position.
! CAUTION
4. Rotate the red adjusting knob by hand or with a flat
head screwdriver until the cam lobe just activates (de-
presses) the switch from a clockwise direction.
The electrical travel switches must be set to activate
(depress) prior to reaching the mechanical travel stops. NOTICE: All actuators have a cam locking screw. Cam
The cams are color coded (green for CCW, red for CW). locking screw must be slackened before cam adjust-
ments and re-tightened after cam adjustments.
NOTE: Manual travel stops are designed to prevent manual
overtravel from turning the handwheel, not to stop the UPPER GREEN
“CCW” CAM
electric motor. The travel stops have an adjustment range
of approximately 10-degrees. LOWER RED
“CW” CAM
CAM
LOCKING
SCREW
5
BRAY Series 70 Tunnel Damper Electric Actuator
Operation and Maintenance Manual
COUNTER-CLOCKWISE TRAVEL SWITCH
ADJUSTMENT
1. Loosen the mechanical stop for the CCW position and
! WARNING
back it off, so that it does not interfere with actua- The heater surface can reach temperatures in excess of
tor travel. The CCW stop is located on the left, when 200 degrees Celsius (392°F)
viewed from travel stop side of actuator.
2. Reference the striker bar for damper position. Heater Kit Consists of:
1. Heater with flying leads
3. Manually operate the actuator handwheel counter-
2. Heater Mounting Bracket
clockwise until the valve reaches the desired CCW
3. #10 pan head screw, Phillips drive
position.
4. Rotate the green adjusting knob until the cam lobe Tools required:
just activates (depresses) the switch from a counter- • For terminal wiring: Screwdriver, 1/4” tip flat blade
DIVISION THIRD ANGLE THE INFORMATION CONTAINED HEREIN ERN DRAWING NO.
CUSTOMER PROJECT
locking screw must be slackened before cam adjust- Installation procedure: SERIES
FLANGE DRILLING 70, SIZE 30 - NYCTA MODEL
ELECTRIC ACTUATOR
CUSTOMER PROJECT NO. PRESSURE RATING
ISOMETRIC EXPLODED VIEW
ments and re-tightened after cam adjustments.
CUSTOMER P.O. NO.
The heater is mounted through a hole provided in the
CERTIFIED CORRECT BY
switchplate.
BUSA Jim Schmidt
NOTE: It is possible that the rotation of one cam will 11/11/2014
move the other cam. If this occurs, hold the other Before servicing unit, switch all power off at the service panel
knobs or cams during adjustment. and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service discon-
5. With the travel switch in the open position, rotate the
necting means cannot be locked, securely fasten a prominent
handwheel counterclockwise 1 turn for Housing Size
warning device, such as a tag, to the service panel.
12 and ½ turn for Housing Size 30. Adjust the CCW
travel stop bolt until it bottoms against the output
gear and lock in position with the locknut.
6. After all travel stop adjustments have been completed,
secure the actuator cover.
HEATER
To prevent condensation from forming inside the actuator,
Bray offers a heater as standard in Series 70 Tunnel
Damper models. The heater is a PTC (Positive Temperature
Coefficient) style which has a unique temperature -
resistance characteristic. The heater self-regulates by
increasing its electrical resistance relative to its temperature.
The heater does not require external thermostats or
switches to control its heat output. It is constructed of
a polycrystalline ceramic, sandwiched between two Disconnect all power to the unit.
conductors, and wrapped inside a thermally conductive 1. Place the heater snugly into its mounting bracket until
electrical insulator. approx. 1/2 to 1” is left above the bracket as shown
Connect the heater wires to the terminal strip as indicated in diagram.
on the wiring diagram. 2. Slip the heater into its mounting hole.
3. Align the fastening hole in the bracket with the
NOTE: The heater must have a constant power supply to
threaded screw hole in the plate. Fasten the heater
be effective.
to the switchplate.
4. Connect the heater wires to the terminal strip as
indicated on the wiring diagram.
6
BRAY Series 70 Tunnel Damper Electric Actuator
Operation and Maintenance Manual
TYPICAL WIRING DIAGRAMS
Wiring diagram for CCW Open Unit with form-ZZ (DPDT-DB) travel switches
(Drawn for actuator in its fully closed [CW] condition)
Note: Bray Series 70 Tunnel Damper electric actuator wiring is the same, regardless of
CW or CWW application. Control is achieved through field wiring.
7
BRAY Series 70 Tunnel Damper Electric Actuator
Operation and Maintenance Manual DIVISION
BUSA
THIRD ANGLE THE INFORMATION CONTAINED HEREIN ERN
SHALL NOT BE COPIED, TRANSFERRED,
CONVEYED OR DISPLAYED IN ANY MANNER ERN-161731
DRAWING NO.
GA-03075
PRIMARY UNITS THAT WOULD VIOLATE ITS PROPRIETARY RELEASED BUSA Cindy Downey SHEET REV.
NATURE WITHOUT THE EXPRESS WRITTEN
R A Division of BRAY INTERNATIONAL, Inc.
DECIMAL INCH PERMISSION OF BRAY INTERNATIONAL,INC. 11/11/2014 3 OF 5 3
CUSTOMER NAME BRAY ORDER NO.
Tools required:
CUSTOMER P.O. NO. CERTIFIED CORRECT BY
mechanical travelDECIMAL
stops.
INCH Remove the 11/11/2014
retaining5 ring
PRIMARY UNITS THAT WOULD VIOLATE ITS PROPRIETARY RELEASED BUSA Cindy Downey SHEET REV.
NATURE WITHOUT THE EXPRESS WRITTEN
R A Division of BRAY INTERNATIONAL, Inc.
OF 5 3 PERMISSION OF BRAY INTERNATIONAL,INC.
CUSTOMER NAME BRAY ORDER NO.
Procedure:
CUSTOMER NAME
R A Division of BRAY INTERNATIONAL, Inc.
BUSA
PRIMARY UNITS
DECIMAL INCH
THIRD ANGLE
WARNING
THE INFORMATION CONTAINED HEREIN ERN
SHALL NOT BE COPIED, TRANSFERRED,
CONVEYED OR DISPLAYED IN ANY MANNER
THAT WOULD VIOLATE ITS PROPRIETARY RELEASED
NATURE WITHOUT THE EXPRESS WRITTEN
PERMISSION OF BRAY INTERNATIONAL,INC.
ERN-161731
DRAWING NO.
GA-03075
BUSA Cindy Downey SHEET
11/11/2014 4 OF 5
REV.
! CAUTION
8. Further disassembly of the unit requires special tools and
procedures, and thus will not be covered in this manual.
8
BRAY Series 70 Tunnel Damper Electric Actuator
Operation and Maintenance Manual
APPENDIX A - BASIC TOOLS
Common To All Units
Terminal connections, cam adjustment Screwdriver, 1/4” tip flat tip blade
All switches, terminal strip, torque switch plate Screwdriver, No.1 Phillips
Switchplate screws, capacitor Screwdriver, No.2 Phillips
9
BRAY Series 70 Tunnel Damper Electric Actuator
Operation and Maintenance Manual
EXPLODED VIEW SERIES 70 TUNNEL DAMPER
1 MODEL HOUSING SIZE 12
2
ON / OFF
3 1 COVER PLATE WITH STUD 38 WORM SHAFT
2 OIL RESISTANT GASKET 39 OVERRIDE DRIVE PIN
3 COVER FASTENING SCREW 40 SPRING PLUNGER
4 4 COVER 41 MANUAL OVERRIDE SHAFT
5 O RING-S271 42 MANUAL OVERRIDE SLEEVE
5 6 STEEL BACK PLATE 43 O RING-S-126
7 WASHER 44 O RING-S118
8 HEX NUT,NYLOCK 45 RETAINING RING
9 INDICATOR SHAFT ASSY 46 HAND WHEEL, CW TO OPEN
10 CCW SWITCH LABEL 47 HANDWHEEL WARNING LABEL
6
11 CW SWITCH LABEL 48 HANDWHEEL CCW TO OPEN
7 12 SWITCH MOUNTING SCREW 49 PIN,SLOT SPRING 1/8”DIA
80 13 FIBER WASHER 50 MANUAL OVERRIDE BUSHING
8
79 9 14 SWITCH ASSY,CCW 51 THRUST WASHER
10 15 SWITCH ASSY,CW 52 THRUST ROLLER BEARING
78 12
11
13
16 COVER PLATE 53 THRUST WASHER
14 17 PAN HD SCREW 54 DISC SPRING
77 18 HEATER MOUNTING BRACKET 55 WORM
15
19 HEATER 56 WORM GEAR ROLL PIN
76 16 20 WIRE ASSEMBLY 57 RETAINING RING
75 21 INSULATOR 58 THRUST WASHER
17 22 O’RIDE SWITCH(SPDT FORM C) 59 BASE
18 23 SCREW, PAN HEAD 60 3/4”-14 NPT PLUG
74 19 24 OVERRIDE SWITCH TRIGGER PIN 61 NAME TAG
73 25 BUSHING 62 BUSHING
72 20 26 THRUST WASHER 63 GEAR SPACER
71 21 27 RETAINING RING 64 DOWEL PIN
70 22 28 OUTPUT WORM GEAR SEGMENT 65 DRIVE GEAR
23 29 O RING-S-128 66 RETAINING RING
24 30 CAPACITOR 67 GEARMOTOR
69 25 31 TERMINAL STRIP 68 LOCK WASHER
26 32 ARMACELL TUBING 69 SOCKET HEAD CAP SCREW
68 33 OVERRIDE SPRING PIN 70 CONDUIT WIRE DEFLECTOR
27
67 28 34 TRAVEL STOP BOLT 71 SWITCH PLATE
29 35 HEX NUT 72 WASHER TERMINAL GROUND
30 36 NYLON FLAT WASHER 73 GROUND SCREW
31 37 O RING 74 FLAT HEAD SCREW
66 32 75 TERMINAL STRIP TAG: 1 - 9
65 33 34 76 TERMINAL STRIP
77 SCREW
64 35
78 TERMINAL STRIP TAG: 10 - 18
63 36
62 79 RELAY KIT
37 80 SCREW, PAN HEAD
61
38 39 40 41 42
51 52
53 54
43 44 45
60 59 58 57
56 55 54 53 52 51 50 49 48 47 46
81
10
BRAY Series 70 Tunnel Damper Electric Actuator
Operation and Maintenance Manual
EXPLODED VIEW SERIES 70 TUNNEL DAMPER
MODEL HOUSING SIZE 30
ON / OFF
1 COVER FASTENING SCREW 38 O RING-S-126
2 COVER 39 O RING-S118
1
3 O-RING 40 RETAINING RING, INTERNAL
4 CAM ASSEMBLY 41 HAND WHEEL, CW TO OPEN
2 5 SWITCH MOUNTING SCREW 42 HANDWHEEL WARNING LABEL
6 FIBER WASHER 43 HAND WHEEL, CCW TO OPEN
3 7 SWITCH ASSY,CCW 44 PIN,SLOT SPRING 1/8”DIA
4 8 SWITCH ASSY,CW 45 MANUAL OVERRIDE BUSHING
76 9 CW SWITCH LABEL 46 THRUST WASHER
5
10 CCW SWITCH LABEL 47 THRUST ROLLER BEARING
75 6
7
11 SWITCH PLATE COVER 48 THRUST WASHER
12 PAN HD SCREW 49 DISC SPRING
74 8 13 HEATER MOUNTING BRACKET 50 WORM
73 9 14 HEATER 51 WORM GEAR ROLL PIN
10 11 15 WIRE ASSEMBLY 52 RETAINING RING,EXT
72
16 INSULATOR 53 THRUST WASHER
71 12 17 O’RIDE SWITCH(SPDT FORM C) 54 BASE
13 18 SCREW, PAN HEAD 55 3/4”-14 NPT PLUG
70 14 19 OVERRIDE SWITCH TRIGGER PIN 56 NAME TAG
20 BUSHING 57 BUSHING
69 15 21 THRUST WASHER 58 DRIVE GEAR KEY
16 22 RETAINING RING 59 DRIVE GEAR
68
17 23 OUTPUT WORM GEAR SEGMENT 60 RET RING, BOWED E-RING
67 18
66 24 O RIBG-S-232 61 GEARMOTOR
19
25 CAPACITOR 62 LOCK WASHER
26 TERMINAL STRIP 63 SOCKET HEAD CAP SCREW
20 27 ARMACELL TUBING 64 DOWEL PIN
21 28 OVERRIDE SPRING PIN 65 SOCKET HEAD SHOULDER SCREW
22 29 TRAVEL STOP BOLT 66 WIRE ENTRY GUARD
23
65 30 LOCK NUT 67 SWITCH PLATE
24 31 NYLON FLAT WASHER 68 WASHER,GROUND TERMINAL
64 25 32 O-RING 69 GROUND SCREW
63 33 WORM SHAFT 70 FLAT HEAD SCREW
26
62
27
34 OVERRIDE DRIVE PIN 71 TERMINAL STRIP TAG: 1 - 9
61 28 35 SPRING PLUNGER 72 TERMINAL STRIP TAG: 10 - 18
60
29 36 MANUAL OVERRIDE SHAFT 73 TERMINAL STRIP
59 37 MANUAL OVERRIDE SLEEVE 74 SCREW
30
58 31 75 RELAY KIT
32 76 SCREW, PAN HEAD
57
56
33 34 35 36 37 38 39 40
46
47
48
49
55 54 53 52
51 50 49 48 47 46 45
44 43 42 41
11
BRAY Series 70 Tunnel Damper Electric Actuator
Operation and Maintenance Manual
12
BRAY Series 70 Tunnel Damper Electric Actuator
Operation and Maintenance Manual
13
R
CONTROLS
A Division of BRAY INTERNATIONAL, Inc.
13333 Westland East Blvd. Houston, Texas 77041
281-894-5454 FAX 281/894-9499 www.bray.com
Bray® is a registered trademark of BRAY INTERNATIONAL, Inc.
© 2014 Bray International. All rights reserved. OM-70TD-001 11-2014