Professional Documents
Culture Documents
PR1012365 - Juniper Networks PR Search
PR1012365 - Juniper Networks PR Search
PR1012365 - Juniper Networks PR Search
Downloads Cases Contracts & Licenses Documentation & Tools Account Assistance MyJuniper
Number PR1012365
Title Improve interface hold-time down behavior on MPC3E, MPC4E, MPC5E, MPC6E cards
Release Note On MX Series routers with MPC3E, MPC4E, MPC5E, and MPC6E, Junos OS does not
support short (sub-second) interface hold-time down configuration. A hidden
configuration statement is introduced to ignore DFE tuning state during the
hold-down timer period. This configuration statement allows sub-second hold-
down timer on MPC3E, MPC4E, MPC5E, and MPC6E: set interfaces <intf name> hold- Your response will be used to improve
time up <U ms> down <D ms> alternative our document content.
Submit
The configuration statement does not work on or support 'MPC5E 3D Q 2CGE+4XGE'
and 'MIC6 2X100GE CFP2 OTN', and therefore we recommend configuring hold-time
down of more than 3 seconds for these two cards.
Severity Major
Status Open
Resolved In
Release junos
15.1X49-D40 x
15.1R3 x
15.1F6 x
16.1R1 x
Product MX-series
Triggers This issue might be seen if the following conditions are met:
** Sub-second hold down timer is configured on ethernet interfaces.
** MPC3E, MPC4E, MPC5E, MPC6E are used.