Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

A B C D E F G H J K L M N P R S T

159054 06-14 RELEASED

ITEM PART NO. REQ'D NAME


1 1
1 SEE TABLE A 1 CONVERTER, CATALYTIC
6
2 CA214476B 1 WIRE WAY ASM., CATALYTIC CONVERTER HARNESS
3 214481A 2 BRACKET, CAT. CONVERTER HEAT SHIELD
13
4 P314941 1 FLEX, EXHAUST, 14"
18 5 5 214493 3 GASKET, EXHAUST FLANGE, 14"

19 6 A740121C 2 SENSOR, TEMP. ASM., RTD, CSA


DOOR HARDWARE TORQUE: 20 FT-LBS
2 22 7 740133 1 SENSOR, STABLESENSE OXYGEN 2
4
INLET 8
9
214565
214494
1
1
BRACKET, O2 SENSOR CONNECTOR
PROBE, EMISSIONS
5
10 194769E 2 CONNECTOR, MALE , 0.25 OD X 1/4 NPT
1
11 214582 1 CONNECTOR, THERMOCOUPLE , 0.38 OD X 3/8 NPT
23 12 21174 2 NUT, HEX STD., .25-20 UNC, STEEL, ZINC PLATED
13 21206 4 NUT, HEX STD., .50-13 UNC, STEEL, ZINC PLATED
19
3 14 21246 39 NUT, HEX STD., 1-8 UNC, STEEL, ZINC PLATED 3
23
15 21274 2 CAPSCREW, HEX HEAD, 1/4-20 X .625 LG., GRADE 5
16 21432 4 CAPSCREW, HEX HEAD, 1/2-13 X 1.500 LG., GRADE 5
23
17 21536 2 WASHER, LOCK , 0.250, ZINC PLATED
18 21539 4 WASHER, LOCK , 0.500, ZINC PLATED
20 19 28839 36 CAPSCREW, HEX HEAD, 1-8 X 3.500 LG., GRADE 5
20 28840 38 WASHER, LOCK , 1.000, ZINC PLATED
4 14 21 28848 2 CAPSCREW, HEX HEAD, 1-8 X 2.500 LG., GRADE 5 4
22 Y18814K 8 WASHER, FLAT .500, PLATED

DETAIL A
23 Y18814R 76 WASHER, FLAT 1.000, PLATED
24 SEE TABLE A 1 TUBE, DELTA P SENSING, LEFT SIDE
SCALE 0.500
25 SEE TABLE A 1 TUBE, DELTA P SENSING, RIGHT SIDE
19 14
20
5 5
SEE NOTE 7 9 23
TABLE A
SEE NOTE 8
11 3 ITEM PART NO. OPTION ITEM PART NO. OPTION

1 214639 1 214639A
SERVICE CODE 1005S
24 214504L 24 214504L
23 VHP 12 Cyl VHP 12 Cyl
6 25 214504M 25 214504M 6

1 214640 1 214640A
SERVICE CODE 1004S
OUTLET 6
24
25
214504X
214504Y
VHP 12 Cyl
24
25
214504X
214504Y
VHP 12 Cyl

NOTES:
7 1. THERE ARE (0) KEY DESIGN FEATURES SHOWN BY PER STD-02-0107. 7
2. PARTS LISTED ARE IN THE 082 GROUP - CATALYTIC CONVERTER.

20 2 SEE NOTES 9 & 10 3. UNLESS OTHERWISE SPECIFIED, THE FOLLOWING TORQUES APPLY
(PLATED THREADS W/ ANTI-SEIZE):
.50-13 UNC 67 FT-LBS
1.00-8 UNC 580 FT-LBS

8 4. APPLY PERMA-BOND LH050 PIPE SEALANT OR ENGINEERING APPROVED


EQUIVALENT TO ALL PIPE THREADS.

MAKE NO REVISIONS ON
THIS REPRODUCIBLE
23 6. APPLY HIGH TEMPERATURE ANTI-SEIZE SUCH AS LOCTITE C5-A OR
20 23 ENGINEERING APPROVED EQUIVALENT TO ALL .25-20 UNC, .31-18 UNC,
14 .50-13 UNC, AND 1.00-8 UNC THREADS.
21 14
7. INSERT EMISSIONS PROBE (ITEM 9) INTO FITTING (ITEM 11) UP TO
SCRIBED LINE ON PROBE.
9

CREO
8. USE SUPPLIED CLAMP TO SUPPORT ENGINE TO CATALYTIC CONVERTER
HARNESS.

B
9. THE WIRE WAY ASSEMBLY (ITEM 2), INCLUDING THE HEAT SHIELD AND

101
SUPPORTING BRACKETS, ARE DESIGNED TO BE MOUNTED ON EITHER
5 7 SEE DETAIL A 8 12 17 15 22 16 SIDE OF THE CATALYTIC CONVERTER UNIT. THE HARNESS CONNECTION

REV No.
MUST ALWAYS BE ON THE INLET SIDE OF THE CONVERTER AS SHOWN.
SEE SHEET 2 FOR INSTRUCTIONS ON ALTERNATING THE ASSEMBLY
10 CONFIGURATION.

159054
10. WHEN MOUNTING THE WIREWAY ASSEMBLY, USE SLOTS IN HEAT SHIELD
MARKED "A" FOR P9394GSI APPLICATIONS AND "B" FOR VHP 12 CYL.
10 24 10 25
APPLICATIONS.

ECO
VIEW FROM ARROW B MODELS DIMENSIONS ARE IN INCHES [MM] GE CLASS II (INTERNAL NON-CRITICAL)
VHP DESCRIPTION

11 12 Cyl GSI GE POWER


INSTALLATION INSTRUCTIONS
emPact DISTRIBUTED POWER CATALYTIC CONVERTER
THIRD ANGLE PROJECTION WAUKESHA, WI
REFERENCE DOCS.
DRW. JJH 1/25/16 THIS DOCUMENT CONTAINS PROPRIETARY/CONFIDENTIAL INFORMATION FILE C.C. PART NO.
S-07232-374 OF GENERAL ELECTRIC COMPANY AND MAY NOT BE USED, COPIED OR

D S-07232-477
DISCLOSED TO OTHERS WITHOUT THE WRITTEN PERMISSION OF
CHK. BID 06/27/16 GENERAL ELECTRIC COMPANY. THE INFORMATION CONTAINED IN THIS
DOCUMENT MAY BE SUBJECT TO US EXPORT CONTROL LAWS.
415
A B C D E F G H J K L M
UNAUTHORIZED EXPORT OR RE-EXPORT IS PROHIBITED.
APP. RHN 06/27/16 COPYRIGHT© 2016, GENERAL ELECTRIC COMPANY SCALE 0.250 SHEET 1 OF 3
A B C D E F G H J K L M N P R S T
159054 06-16 RELEASED

1 1
STEP 1 ALTERNATING ASSEMBLY CONFIGURATION STEP 2
(CAT. CONVERTER HARNESS WIRE WAY ASSEMBLY)

SEE STEP a.

2 2

SEE STEP a.

3 3

4 4

SEE STEP b.

5 5
SEE STEP b.

DISASSEMBLY:
a. REMOVE HARDWARE AND PULL WIRE WAY OFF OF BRACKETS ROTATE HEAT SHIELD 180 $ (HARNESS CLAMP WILL ALWAYS
b. REMOVE HARDWARE MOUNTING BRACKETS TO HEAT SHIELD, BE ON THE INLET SIDE OF THE CATALYTIC CONVERTER)
6 REMOVE BRACKETS 6

STEP 3 STEP 4

7 7

MAKE NO REVISIONS ON
THIS REPRODUCIBLE
9

CREO
101
REV No.
10
ROTATE WIRE WAY 180° SO THAT IT MATCHES ORIENTATION SHOWN,

159054
ASSEMBLE WIRE WAY TO BRACKETS - APPLY A TORQUE OF 183 IN-LBS

FASTEN BRACKETS TO HEAT SHIELD - APPLY A TORQUE OF 67 FT-LBS

ECO
MODELS DIMENSIONS ARE IN INCHES [MM] GE CLASS II (INTERNAL NON-CRITICAL)
VHP DESCRIPTION

11 12 Cyl GSI GE POWER


INSTALLATION INSTRUCTIONS
emPact DISTRIBUTED POWER CATALYTIC CONVERTER
THIRD ANGLE PROJECTION WAUKESHA, WI
REFERENCE DOCS.
DRW. JJH 1/25/16 THIS DOCUMENT CONTAINS PROPRIETARY/CONFIDENTIAL INFORMATION FILE C.C. PART NO.
S-07232-374 OF GENERAL ELECTRIC COMPANY AND MAY NOT BE USED, COPIED OR

D S-07232-477
DISCLOSED TO OTHERS WITHOUT THE WRITTEN PERMISSION OF
CHK. BID 06/27/16 GENERAL ELECTRIC COMPANY. THE INFORMATION CONTAINED IN THIS
DOCUMENT MAY BE SUBJECT TO US EXPORT CONTROL LAWS.
415
A B C D E F G H J K L M
UNAUTHORIZED EXPORT OR RE-EXPORT IS PROHIBITED.
APP. RHN 06/27/16 COPYRIGHT© 2016, GENERAL ELECTRIC COMPANY SCALE 0.250 SHEET 2 OF 3
A B C D E F G H J K L M N P R S T
159054 06-16 RELEASED

1 1

2 2

INLET
3 3

4 4
OUTLET
OUTLET

5 5

6 6

7 7

SLIDE CONNECTORS INTO CLIPS ON


WIRE WAY IN ORIENTATION SHOWN SLIDE CONNECTORS INTO CLIPS ON
8 WIRE WAY IN ORIENTATION SHOWN

INLET

MAKE NO REVISIONS ON
THIS REPRODUCIBLE
WIRE WAY ASSEMBLY MOUNTED ON SIDE 1 WIRE WAY ASSEMBLY MOUNTED ON SIDE 2
9

CREO
101
REV No.
10

159054
ECO
MODELS DIMENSIONS ARE IN INCHES [MM] GE CLASS II (INTERNAL NON-CRITICAL)
VHP DESCRIPTION

11 12 Cyl GSI GE POWER


INSTALLATION INSTRUCTIONS
emPact DISTRIBUTED POWER CATALYTIC CONVERTER
THIRD ANGLE PROJECTION WAUKESHA, WI
REFERENCE DOCS.
DRW. JJH 1/25/16 THIS DOCUMENT CONTAINS PROPRIETARY/CONFIDENTIAL INFORMATION FILE C.C. PART NO.
S-07232-374 OF GENERAL ELECTRIC COMPANY AND MAY NOT BE USED, COPIED OR

D S-07232-477
DISCLOSED TO OTHERS WITHOUT THE WRITTEN PERMISSION OF
CHK. BID 06/27/16 GENERAL ELECTRIC COMPANY. THE INFORMATION CONTAINED IN THIS
DOCUMENT MAY BE SUBJECT TO US EXPORT CONTROL LAWS.
415
A B C D E F G H J K L M
UNAUTHORIZED EXPORT OR RE-EXPORT IS PROHIBITED.
APP. RHN 06/27/16 COPYRIGHT© 2016, GENERAL ELECTRIC COMPANY SCALE 0.250 SHEET 3 OF 3

You might also like