Panasonic Cs Cu Pn18ukj

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

AIR CONDITIONER

2017/2018

ELITE INVERTER

N E W P R E M I U M I N V E RT E R

Please read the Installation Instructions carefully before installing the unit,
and the Operating Instructions before using it.
Specifications are subject to change without prior notice.
The contents of this catalogue are accurate as of January 2017.
Due to printing considerations, the actual colours may vary slightly from those shown.
All graphics are provided merely for the purpose of illustrating a point.

Do not add or replace refrigerant other


than the specified type. Manufacturer
is not responsible for the damage and
deterioration in safety due to usage of
other refrigerant.

AC-IND-C-17
CONTENTS KAI KEN BI

!"#$%#$& $'%()'*+"&")',("-().#.&"#*!

02 - 03 20 - 21
At Panasonic, air conditioning is more than just about cool air.
KAI KEN BI INVERTER It is about how cool air is delivered to create a living space that
brings you comfort when you need it most, takes care of
04 - 05 22 - 33 your health and beautifies your homes and lives.
#AIRTHATMOVESYOU PRODUCT LINE-UP
DIRECT & INDIRECT COOLING
34 - 35
06 - 07 RADIANT COOLING
SKY SERIES TECHNICAL EXPLANATION KAI KEN

08 - 09 36 - 39
AERO SERIES nanoe-G
TECHNICAL EXPLANATION
10 - 11
DIRECT COOLING 40 - 41
-SKY SERIES iAUTO-X & iAUTO
TECHNICAL EXPLANATION BI
12 - 13
DIRECT COOLING 42 - 43
-AERO SERIES FEATURES COMPARISON

14 - 15 44 - 45
INDIRECT COOLING FEATURES EXPLANATION
-SKY SERIES COMFORT
& ACCESSORIES
Essential air conditioner functions
KAI that cool you in a more natural way.
16 - 17 46 - 47
INDIRECT COOLING MODEL LINE-UP
-AERO SERIES HEALTH

Clean and fresh air that


18 - 19 KEN improves your health and wellbeing.
nanoe-G
BEAUTY

Minimalist and modern air conditioners


BI that beautify your home.

02 04
02 03
#AIRTHATMOVESYOU DIRECT COOLING & INDIRECT COOLING

!"#$%&'()*%+',-
Is it the uplifting feeling of a cool gentle breeze? For the perfect cooling experience,
Or is it the exhilarating blast of cool air on a hot day? Panasonic Air Conditioners are designed
to deliver comfort through Direct Cooling
Experience cooling comfort inspired by nature with
and Indirect Cooling.
Panasonic SKY Series and AERO Series.

! "#$%&$'()*+,(- DIRECT COOLING

Cools you fast with powerful and concentrated cool air


at start up.
SKY Series AERO Series

INDIRECT COOLING

Cools you gently after reaching the set temperature


by cooling your surroundings.
SKY Series AERO Series

NEW

04 04 05
SKY SERIES SKY SERIES

ELITE INVERTER

A I R CO N D I T I O N E R

!"#.+-,
6.<:,1*LVDQLQQRYDWLYHWRSIODSWKDWFDQEHWWHUGLUHFW
FRRODLUWRZDUGVWKHFHLOLQJ7KHFRRODLUWKHQQDWXUDOO\
glides along the ceiling surface, spreading throughout
the room and down the walls. Heat is removed
from the ceiling and walls, resulting in a feeling of even,
DOOURXQGFRROQHVVä5$',$17&22/,1*

CONTROLLED BY A MULTIDIRECTIONAL ARM

!"#$!%&'()$*'!+,-

7KH6.<675($0GHVLJQKLJKOLJKWVPRGHUQDQGPLQLPDOLVWOLQHVPDNLQJLW SKYWING can cool you in two ways :


DOX[XULRXVFRPSOHPHQWWRGHVLJQHULQWHULRU DIRECT COOLING INDIRECT COOLING

MODERN & MINIMALIST SLIDING LED PANEL BACKLIT FAST COOLING RADIANT COOLING
LINES SKY CONTROLLER SKYWING angles downwards After reaching the set temperature,
î6OHHNDQGVWULNLQJGHVLJQ î:KHQVZLWFKHGRQ î%DFNOLW/('6FUHHQ to deliver powerful airflow SKYWING angles upwards to direct
î/X[XULRXVFRPSOHPHQW the panel slides open î'LVWLQFWLYH6OLGLQJ&RYHU at start up. cool air towards ceiling and walls,
to designer interior. to reveal its setting î3UHFLVH7HPSHUDWXUH spreading cool air evenly
Please refer to Pg10-11
indicators.  &RQWURO$GMXVWDEOHDW throughout the room.
 r&
Please refer to Pg14-15

06 07
AERO SERIES AERO SERIES

N E W P R E M I U M I N V E RT E R

AIR CONDITIONER

!"#$-(,+&
AEROWINGS are flexible twin flaps that can direct and
FRQFHQWUDWHDLUIORZWRFRRODQDUHDHIIHFWLYHO\7KHVHIODSV
are able to channel and concentrate cool air upwards,
which showers down over the room for gentle
DQGHYHQFRROQHVVä6+2:(5&22/,1*

AEROWINGS WITH FLEXIBLE TWIN FLAPS

!"#$%&'()%*"&(+,

7KH$(526/,0GHVLJQIHDWXUHVVOHHNOLQHVDQGJUDFHIXOFXUYHVZKLOH AEROWINGS can cool you in two ways :


the lustrous pearl finishing and chrome escutcheon exude a sense of luxury. DIRECT COOLING INDIRECT COOLING

236mm 199mm

2016 2017 AERO Series

SLIM & SLEEK OUTLINE LUSTROUS PEARL AERO CONTROLLER FAST COOLING SHOWER COOLING
FINISHING AEROWINGS twin flaps AEROWINGS angles upwards to
îPPVOLPPHUWKDQ î&ODVV\WRQHZLWKDVRIW î3UHFLVH7HPSHUDWXUH angle downwards to deliver spread cool air over a wider area,
previous models. pearly glow. Control - Adjustable at concentrated airflow to cool then showers down gently
î&KURPHHVFXWFKHRQZLWK 0.5°C. you instantly at start up. and evenly across the room after
a sense of luxury. reaching the set temperature.

Please refer to Pg16-17


Please refer to Pg12-13

*AEROWINGS now available across all models. Design may vary according to models.

08 09
DIRECT COOLING - SKY SERIES DIRECT COOLING - SKY SERIES
ELITE INVERTER

A I R CO N D I T I O N E R

!"#$%&'%(()"*+
,(-$#./)'.01&'%(()"*+
.223'&42'&45633678'%993'-67:

At start up, SKYWING tilts down to bring you powerful and direct airflow
to cool down instantly. Together with the high-powered Inverter compressor
technology, P-TECh, SKY Series can achieve the desired temperature
in the shortest time possible.

How DIRECT COOLING works in SKY Series:

1 Powerful cool air is


1 directed downwards
at start up.

2 The steady airflow


%0#$1 cools you down quickly.

.(#';(/#' 2
$*<(;=$*&

P-TECh – THE POWER BEHIND FAST COOLING AIRFLOW ASSESSMENT


FAST COOLING AIRFLOW TEMPERATURE DISTRIBUTION TEST
P-TECh
SMOKE TEST

î&RROV<RX'RZQ 
Instantly At Start Up P-TECh enables the compressor to achieve warmer cooler
maximum frequency in the shortest time
SKYWING directs CONVENTIONAL FAST COOLING
from start up, giving you powerful cooling
airflow downwards COOLING
the moment the air conditioner is switched on.
and straight to Cool air blows Powerful airflow
DASH & HIGH COMPRESSOR FREQUENCY room occupants for downwards and cools cools rapidly.

Y
2017 Panasonic a fast cooling effect.

EQUENC
the room at a slow Room is evenly cooled.

Compressor Frequency (Hz)


HIGHEST FREQUENCY

P-TECh
pace, resulting in

MAX FR
2014 Panasonic
uneven cooling.

DASH TO
The edge of the room
remains warm.

Time (min.)

10 11
DIRECT COOLING - AERO SERIES DIRECT COOLING - AERO SERIES
N E W P R E M I U M I N V E RT E R

AIR CONDITIONER

2.%$-,)-""(./0
!"#$%&'()&*+,)-""(./0
#.,1)-"/-$/,%*,$2)*.%&("#
34)0544647)#869)*)3:;<6)"= )->>:)*85

AEROWINGS with twin flaps direct airflow downwards, delivering concentrated


cool air the moment you switch on the air conditioner.

How DIRECT COOLING works in AERO Series:

1 Concentrated cool air


is delivered straight
1 to you.

2 The steady airflow


-*%$+ cools you down quickly.
2
&"%)?"'%)
$/@"?A$/,

P-TECh – THE POWER BEHIND FAST COOLING AIRFLOW ASSESSMENT


FAST COOLING AIRFLOW TEMPERATURE DISTRIBUTION TEST
P-TECh
SMOKE TEST

î,QVWDQW5HOLHI
From The Heat P-TECh enables the compressor to achieve warmer cooler
maximum frequency in the shortest time
AEROWINGS directs CONVENTIONAL FAST COOLING
from start up, giving you powerful cooling
airflow downwards COOLING
the moment the air conditioner is switched on.
and straight to Cool air blows Concentrated airflow
DASH & HIGH COMPRESSOR FREQUENCY room occupants for downwards and cools cools instantly.

Y
2017 Panasonic a fast cooling effect.

EQUENC
the room at a slow Room is evenly cooled.

Compressor Frequency (Hz)


HIGHEST FREQUENCY

P-TECh
pace, resulting in

MAX FR
2014 Panasonic
uneven cooling.

DASH TO
The edge of the room
remains warm.

Time (min.)

12 13
INDIRECT COOLING - SKY SERIES INDIRECT COOLING - SKY SERIES
ELITE INVERTER

A I R CO N D I T I O N E R

$%#$!;(&'())*$%+
!"#$"%&'())*$%+
#,-./012'%345236'"667!/589'(//6,8:

RADIANT COOLING is inspired by caves, where the cool surfaces


create an all-round cooling effect. After reaching the set temperature,
SKYWING angles upwards to direct airflow towards ceiling and walls
to remove the heat trapped in these surfaces for
an overall cool environment.

How RADIANT COOLING works:

1 Cool air is directed


2 towards the ceiling.
1 Cool air spreads
2
evenly throughout
the room.
("!;< 3
Heat trapped in
=)!'>)?! 4
3
ceiling and walls
@;**%;<< is removed.

4 Room is evenly
cooled down.
How RADIANT COOLING works:

RADIANT COOLING AIRFLOW ASSESSMENT


AIRFLOW TEMPERATURE BOTTOM AIR INTAKE
SMOKE TEST DISTRIBUTION TEST

î &RROLQJ(IIHFW 
Inspired By Caves
warmer cooler
That Prevents Instead of blowing RADIANT COOLING Hot air is drawn in
 ([FHVVLYH&RROLQJ cold air directly onto SKYWING directs from the bottom,
people, SKYWING cool air upwards, and cool air is
directs the airflow removing heat from discharged from
î 6NLQ6WD\V upwards to cool ceiling and walls the top to facilitate
the ceiling and walls. for an all-round the even distribution
Moist And Supple cooling effect. of cool air.

14 15
INDIRECT COOLING - AERO SERIES INDIRECT COOLING - AERO SERIES
N E W P R E M I U M I N V E RT E R

AIR CONDITIONER

*+8*&%(='(##)*+,
!"#$%&'(##)*+,
-../',.01/.'(22/')34.'5260307'8.9

SHOWER COOLING is the feeling that gently washes over you


like a cool morning. After reaching the set temperature, AEROWINGS
directs airflow upwards to spread cool air evenly across the room,
and showers down for endless comfort.

How SHOWER COOLING works:

1 Cool air is directed


1 upwards.

2 Cool air
2
spreads evenly
(:&%! and showers down.
3
-#&';#<&' Room is evenly
3
(#5-#&= cooled down.

SHOWER COOLING AIRFLOW ASSESSMENT


AIRFLOW TEMPERATURE TOP AIR INTAKE
SMOKE TEST DISTRIBUTION TEST

î3UHYHQWV2YHUFRROLQJ
From Direct Airflow warmer cooler

Instead of blowing SHOWER COOLING Hot air is drawn in


cold air directly onto AEROWINGS directs from the top, and
people, AEROWINGS cool air further cool air is discharged
directs airflow and higher towards from the bottom to
upwards over the ceiling to avoid facilitate cool air
a wider area, direct cooling. showering down over
then showers down the entire area.
gently and evenly
across the room.

16 17
AIR PURIFICATION SYSTEM AIR PURIFICATION SYSTEM

".#&1*#.'.!"2.(/
%)%2$3 -9567>5&'95?>&@&!A56;

)RURYHUDOOZHOOEHLQJ3DQDVRQLF$LU&RQGLWLRQHUVIHDWXUH
DQDGYDQFHGDLUSXULILFDWLRQV\VWHPFDOOHGQDQRHG
ZKLFKUHOHDVHVDFWLYHLRQVWKDWDWWDFKWRSDUWLFOHVDVVPDOODV30
How nanoe-G works:

1 AIRBORNE

Airborne particles:
Natural Ion Wind 3 trillion*
PM2.5
Bacteria Viruses Mould
spreads nanoe-G nanoe-G
fine particles that fine particles
are released from released from the

!"#$%&'(#& the nanoe-G


generator.
generator.

)(*#& IN-FILTER Remark:


* 3 trillion is the simulated number
DEACTIVATION of nanoe-G fine particles under

+$,,-$./0 Mechanism
Odour Particle nanoe-G
nanoe-G catches
airborne particles
3 the mentioned conditions. Actual
measured nanoe-G fine particles
at the centre of the room
(13m2):100k/cc calculated number
of nanoe-G fine particles in the
ADHESIVE
2
entire room assuming they are
evenly distributed.
Strike Odour Particles Decompose and Remove Odour

1 2 3
REMOVES DEACTIVATES ADHESIVE IN-FILTER DEACTIVATION
AIRBORNE PARTICLES PARTICLES & DEODORISES (Up to 99%*4)
(Up to 99%*1 *2) ADHESIVE ODOURS
(Up to 99%*3) 'HDFWLYDWHVEDFWHULDDQG
5HPRYHVDLUERUQHSDUWLFOHV YLUXVHVWUDSSHGLQWKHILOWHU
HYHQGRZQWR30*1 'HDFWLYDWHVDGKHVLYH 3OHDVHUHIHUWR3J
*4

7KHVHSDUWLFOHV LQFOXGH PLFURRUJDQLVPVDQG


î)UHVKHU EDFWHULDYLUXVHVDQGPRXOG GHRGRULVHVDGKHVLYHRGRXUV
  
3OHDVHUHIHUWR3J
,QKLELWVPRXOGJURZWKWKDW
 $QG&OHDQHU$LU VHWWOHVRQVXUIDFHVDURXQG\RX

3OHDVHUHIHUWR3J

456789:;< &=*%2&%$/%(#
*Only applicable to SKY Series.

6.<6HULHVDOVRIHDWXUHVDQDGGLWLRQDO'8676(1625
ZKLFKFRQVWDQWO\PRQLWRUVDLUTXDOLW\DQG
DXWRPDWLFDOO\DFWLYDWHVQDQRHGZKHQDKLJKOHYHO
RISDUWLFOHFRQFHQWUDWLRQLVGHWHFWHG

18 19
INVERTER INVERTER

$.$#0)(%"1-.0%
6DYHVHQHUJ\E\DOWHUQDWLQJFRPSUHVVRUVSHHG +9:;<4:(=:7>:965?9:(!23592@
,19(57(5SUHYHQWVZDVWHIXOHQHUJ\FRQVXPSWLRQE\YDU\LQJ
WKHFRPSUHVVRUURWDWLRQVSHHGWRPDLQWDLQWKHVHWWHPSHUDWXUH

NON-INVERTER
Room Big temperature
temperature fluctuations

$FRQYHQWLRQDOQRQ,19(57(5DLUFRQGLWLRQHU
Set
temperature FDQRQO\RSHUDWHDWDFRQVWDQWVSHHGZKLFKLVWRR
SRZHUIXOWRPDLQWDLQWKHVHWWHPSHUDWXUH7KXVLW

Output power
VZLWFKHVWKHFRPSUHVVRURQDQGRIIUHSHDWHGO\
ON OFF ON OFF ON
7KLVUHVXOWVLQZLGHUWHPSHUDWXUHIOXFWXDWLRQV
Time
OHDGLQJWRZDVWHIXOFRQVXPSWLRQRIHQHUJ\
!"#$% Legend: Output Power Temperature

&'#()'*#(
Remark: Energy is wasted by switching the compressor
ON and OFF to maintain the set temperature.

+$"!$('&(,-./ INVERTER

Room Little temperature


temperature fluctuations
7KH3DQDVRQLF,19(57(5DLUFRQGLWLRQHUYDULHVWKH
URWDWLRQVSHHGRIWKHFRPSUHVVRUSURYLGLQJD
SUHFLVHPHWKRGRIPDLQWDLQLQJWKHVHWWHPSHUDWXUH

Output power
Set temperature
7KXV3DQDVRQLF,19(57(5DLUFRQGLWLRQHUVJLYH
ON
\RXH[FHSWLRQDOHQHUJ\VDYLQJSHUIRUPDQFHZKLOH
Time
HQVXULQJ\RXVWD\FRPIRUWDEOHDWDOOWLPHV
Legend: Output Power Temperature
Remark: Saves energy by varying the rotation speed of the
compressor to maintain the set temperature.

î 6WD\&RPIRUWDEOH !2345635(!278295
 :KLOH6DYLQJ(QHUJ\
3UHFLVHWHPSHUDWXUHFRQWUROZLWKDZLGHSRZHURXWSXWUDQJHHQDEOHVDQ
,19(57(5DLUFRQGLWLRQHUWRPHHWGLIIHUHQWURRPRFFXSDQF\OHYHOVäWKXV
î 3UHFLVH7HPSHUDWXUH HQVXULQJFRQVWDQWFRPIRUW
 &RQWURO
MAXIMUM POWER MEDIUM POWER MINIMUM POWER

î6DYHRQ
 (OHFWULFLW\%LOOV
Compressor rotation speed: HIGH Normal condition Compressor rotation speed: SLOW
When required, the unit operates When not required, the unit operates
at full power. at low power to save energy.
Power: 4.20kW Power: 3.67kW Power: 0.92kW

Graph shows the 1.5HP PREMIUM INVERTER model’s wide power output range during cooling.

20 21
PRODUCT LINE-UP PRODUCT LINE-UP

WALL-MOUNTED : !"#$! Single-Split Type

BACKLIT SKY CONTROLLER

Enjoy innovative design at your


fingertips with the new stylish and
sleek Backlit Sky Controller.

With fast access to key operations


and a smooth gliding cover
revealing more options, controlling
CS-VU10SKP | CS-VU13SKP | CS-VU18SKP Wireless Wired (Optional) your settings has become simple
and intuitive.

With a width of 58.9mm and (CS-VU10SKP)

a length of 164.7mm, the Sky 22.0mm


SPECIFICATIONS Cooling ( ): Outdoor Unit
Controller fits comfortably into
MODEL (50Hz) CS-VU10SKP CS-VU13SKP CS-VU18SKP
[CU-VU10SKP] [CU-VU13SKP] [CU-VU18SKP] your hand. COOLING MODELS
(min-max) kW 2.55 (0.84-3.20) 3.40 (1.02-4.20) 5.20 (1.10-5.80)
Cooling Capacity
(min-max) Btu/h 8,700 (2,860-10,900) 11,600 (3,480-14,300) 17,700 (3,750-19,800) RADIANT COOLING DUST SENSOR

EER (min-max) Btu/hW 13.81 (12.71-12.39) 14.15 (12.21-12.43) 12.21 (12.93-11.86)

Voltage V 220 - 240


Electrical Data Current A 3.1 - 2.9 4.0 - 3.7 7.0 - 6.4 1 Backlit LED screen lets you view
operations status in the dark.
Power Input (min-max) W 630 (225-880) 820 (285-1,150) 1,450 (290-1,670)

L/h 1.6 2.0 2.9 2 Power Button. (Random)


Moisture Removal
(Pt/h) 3.4 4.2 6.1
Indoor m3/min (ft3/min) 10.5 (370) 12.0 (425) 13.4 (475) 3 iCOMFORT lets you come home to
Air Circulation fast cooling. Then enjoy continuous CS-VU10SKP CS-VU18SKP
Outdoor m3/min (ft3/min) 21.6 (760) - 24.9 (880) 29.0 (1,020) - 30.4 (1,070) 34.9 (1,230) - 34.9 (1,230) (Optional)
comfort with RADIANT COOLING CS-VU13SKP

Indoor (H / L / Q-Lo) dB (A) 36/25/18 - 36/25/18 41/27/19 - 41/27/19 46/36/33 - 46/36/33 which avoids direct cooling. 1
Noise Level
Outdoor (H / L) dB (A) (47) - (48) (48) - (49) (49) - (49)
mm 318 (511) 318 (542) 318 (619) 4 Press up or down to set the 2
Height temperature. 3
inch 12-17/32 (20-1/8) 12-17/32 (21-11/32) 12-17/32 (24-3/8) 4 OUTDOOR
mm 950 (650) 950 (780) 950 (824) Toggles between RADIANT COOLING 5
Dimensions Width 5
inch 37-13/32 (25-19/32) 37-13/32 (30-23/32) 37-13/32 (32-15/32) (INDIRECT) and Fast Cooling (DIRECT).
7
*The term “RADIANT” was replaced based on 6 8
mm 280 (230) 280 (289) 280 (299)
Depth running change effective for new 2017 production.
inch 11-1/32 (9-1/16) 11-1/32 (11-13/32) 11-1/32 (11-25/32)
9 10
Indoor kg (lb) 13 (29) 13 (29) 13 (29) 6 Activates the nanoe-G even when CU-VU10SKP
Net Weight
Outdoor kg (lb) 21 (46) 29 (64) 33 (73)
the air conditioner is switched off.
11
mm ø 6.35
Liquid Side 7 Set the airflow.
Refrigerant Pipe inch 1/4
12
Diameter mm ø 9.52 ø 12.70
Gas Side 8 Adjusts the fan speed.
inch 3/8 1/2 CU-VU13SKP
Chargeless Pipe Length m 7.5 10
9 Toggles between COOL and DRY
Maximum Pipe Length m 20 30 setting mode.
Pipe Extension
Maximum Elevation Length m 15 20

Additional Refrigerant Gas** g/m 10 15 10 Delays off timer with temperature


Power Supply
control for better sleep.
Indoor

CU-VU18SKP
11 Set the 24-hour ON & OFF Timer or
Caution For CS-VU10/VU13/VU18SKP (Important) Please do not use copper pipes that are less than 0.6mm in thickness.
*When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit. 24-hour Dual ON & OFF Timer.

12 Set the actual time [hour and


minute].

Wireless
Applicable to ELITE Inverter

22 23
PRODUCT LINE-UP PRODUCT LINE-UP

WALL-MOUNTED : STANDARD Single-Split Type

EASY-TO-USE REMOTE CONTROLLER

Panasonic’s wireless remote controller features a large


Liquid Crystal Display (LCD) panel which makes it even
Wireless Wired (Optional) more user-friendly. So you can sit back and enjoy easy
CS-PU9TKP | CS-PU12TKP
operation and long-lasting comfort from your Panasonic
Air Conditioner.

1 LCD display for an easy overview of


the operation status.

2 Come home to fast cooling. Then


enjoy continuous comfort with Shower
CS-PU18TKP | CS-PU24TKP Wireless Wired (Optional) Cooling which avoids direct cooling.

SPECIFICATIONS Cooling ( ): Outdoor Unit 3 Toggles between iAUTO, COOL and COOLING MODELS
DRY setting mode. 1
MODEL (50Hz) CS-PU9TKP CS-PU12TKP CS-PU18TKP CS-PU24TKP
[CU-PU9TKP] [CU-PU12TKP] [CU-PU18TKP] [CU-PU24TKP] 4 Press up or down to set the
(min-max) kW 2.50 (0.84 - 2.73) 3.50 (0.92 - 4.00) 5.20 (1.10 - 5.80) 6.10 (1.12 - 6.90) temperature.
Cooling Capacity 2 SLEEP
(min-max) Btu/h 8,530 (2,860 - 9,310) 11,900 (3,140 - 13,600) 17,700 (3,750 - 19,800) 20,800 (3,820 - 23,500) CS-PU9TKP CS-PU18TKP
5 Delays off timer with temperature 4 CS-PU12TKP CS-PU24TKP
EER (min-max) Btu/hW 12.36 [12.17 - 11.22] 12.02 [11.63 - 11.33] 12.29 [12.50 - 11.58] 11.95 [11.58 - 10.68] control for better sleep. 3
Voltage V 220
CS-PU9TKP (Random)
Electrical Data Current A 3.4 4.8 6.9 8.3 6 Quiet function allows you to sleep 5
CS-PU12TKP

comfortably at night. 8
Power Input (min-max) W 690 (235 - 830) 990 (270 - 1,200) 1,440 [300 - 1,710] 1,740 (330 - 2,200) 7
20m 30m
L/h 6
1.5 2.0 2.9 3.4 (Optional) CS-PU9TKP CS-PU18TKP
Moisture Removal 7 Adjusts the fan speed. CS-PU12TKP
CS-PU24TKP
(Pt/h) 3.2 4.2 6.1 7.2
Indoor m3/min (ft3/min) 9.9 10.9 17.7 18.1 9
Air Circulation
8 Set the airflow.
Outdoor m3/min (ft3/min) 350 385 625 640
Indoor (H / L / Q-Lo) dB (A) 36/26/23 38/28/25 44/32/29 45/36/31 9 Set the 24-hour ON & OFF Timer or 10
Noise Level
Outdoor (H / L) dB (A) 46 47 49 51
24-hour Dual ON & OFF Timer.
mm 296 (511) 296 (542) 296 (619) 296 (695)
OUTDOOR
Height 10 Set the actual time (hour and
inch 11-21/32 (20-1/8) 11-21/32 (21-11/32) 11-21/32 (24-3/8) 11-21/32 (27-3/8) minute).
mm 870 (650) 870 (780) 1,070 (824) 1,070 (875)
Dimensions Width
inch 34-9/32 (25-19/32) 34-9/32 (30-23/32) 42-5/32 (32-15/32) 42-5/32 (34-15/32)
Wireless CU-PU9TKP
mm 236 (230) 236 (289) 241 (299) 241 (320)
Depth Applicable to CS-PU18/24TKP
inch 9-5/16 (9-1/16) 9-5/16 (11-13/32) 9-1/2 (11-25/32) 9-1/2 (12-5/8)
Indoor kg (lb) 9 (20) 9 (20) 12 (26) 12 (26)
Net Weight
Outdoor kg (lb) 20 (44) 27 (60) 33 (73) 46 (101)
mm ø 6.35
Liquid Side CU-PU12TKP
Refrigerant Pipe inch 1/4
Diameter mm ø 9.52 ø 12.70 ø 15.88
Gas Side TO SET THE TIMER
inch 3/8 1/2 5/8
Chargeless Pipe Length m 7.5 10
To turn the unit ON or OFF at a preset time.
Maximum Pipe Length m 20 30 20
Pipe Extension 1 2 3
Maximum Elevation Length m 15 20
TIMER CU-PU18TKP
Additional Refrigerant Gas* g/m 10 15 25 ON SET

1 2 33
Power Supply Indoor OFF CANCEL
CAN CEL

Caution For CS-PU9/PU12/PU18/PU24TKP (Important) Please do not use copper pipes that are less than 0.6mm in thickness.
*When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit. Select ON or OFF Timer Set the time.
Example:
OFF at 22:00
OFF
CU-PU24TKP
2

Confirm.
SET
TIMER

26 27
RADIANT COOLING TECHNICAL EXPLANATION RADIANT COOLING TECHNICAL EXPLANATION

!"#$"%&'())*$%+ Conventional air conditioner SKY SERIES

,)!'-./!.0 COOLS GENTLY AND EVENLY

()1,)!&'())*$%+
The SKY Series makes the room evenly cool, even though no airflow feeling.
The cooling system of SKY Series gives comfort based on the principle of RADIANT COOLING.
28 28 The temperature in
27 27
26 26 all areas of the room
25 ”It's comfortable!" 25 can be evenly set at
24 24 ”It's comfortable!"
Temperature 23
22
23
22
a comfortable level.
21 "It's cold!" 21
distribution 20 20
19 19
18 18
17 17
˚C ˚C

Conventional air conditioners are built to blow cold air downwards


Discharge airflow Comfortable in living
and directly at people to cool them instantly. However, when in
No Air Feeling Area Intake airflow
space with no wind
"I feel cold wind!" "I don’t feel much wind!" (less than 0.2 m/s*)

direct contact with cold air for too long, some people experience Air velocity
distribution Discharge
No Air Feeling Area
*Meter per second

airflow
discomfort and dry skin. No Air Feeling Area
Intake airflow

Test conditions: Measured in stable operation at 25˚C cooling with fan speed set at "HI."
Inspired by the cooling effect of caves,
Doctor Naoshi Kakitsuba investigated the
benefits of RADIANT COOLING. He found that this RADIANT COOLING REMOVES HEAT FROM CEILING AND WALLS
gentler and more even cooling method results in
a greater feeling of comfort and wellbeing. SKY Series makes people comfortable because the radiant heat from ceiling is less.

DR NAOSHI KAKITSUBA
Average Average
ceiling temperature: ceiling temperature:
DEPT. OF ENVIRONMENTAL 35˚C 30˚C
SCIENCE AND TECHNOLOGY, Radiant heat
from roof top
MEIJO UNIVERSITY JAPAN and ceiling
Mean Radiant Temperature Mean Radiant Temperature
(Measured by Globe Thermometer) (Measured by Globe Thermometer)
Average 26.2˚C Average 26.2˚C
room temperature: room temperature:
25˚C 25˚C
The globe temperature is about 0.8˚C higher
(=About 1.1˚C higher in terms of how people feel comfortable)
The globe temperature is a composite temperature used to estimate the
effect of temperature, humidity, and solar radiation on humans.

Slightly
THE PRINCIPLE OFTHE PRINCIPLE
RADIANT OF RADIANT COOLING
COOLING uncomfortable Slightly Comfortable
comfortable

20%
Sensation

100%
evaluation
Room
Heat is absorbed by the breeze on the skin, Temp.
Room
Temp.
resulting in a cool feeling. 25 ºC 25 ºC
Conventional Cooling Slightly comfortable Comfortable /
Neither or
Slightly comfortable
Conventional air conditioner Slightly
any side comfortable

The breeze directly contacts Measured in stable operation at 25˚C cooling with fan speed set at "MEDIUM." The actual average room temperature is the same.

the body for cooling.

THE BENEFITS OF RADIANT COOLING


Heat is absorbed by the cool surrounding
SKYWING angles upwards to cool without direct airflow,
walls and ceiling, resulting in a cool feeling.
RADIANT COOLING thus PREVENTING OVERCOOLING AND MAINTAINS SKIN MOISTURE.
SKY SERIES

60 min. 60 min.

71% 98%
Skin moisture
after 60 minutes 210μS 150μS 210μS 206μS
The breeze cools the walls and ceiling,
which absorb the body heat.
Measured in stable operation at 25˚C cooling with fan speed set at "HI."

*Applicable to ELITE INVERTER only.


*All test results are based on internal test.

34 35
nanoe-G TECHNICAL EXPLANATION nanoe-G TECHNICAL EXPLANATION

!"#$%&'%()*+,-% $".%.//.0$&1.2.''%3/%()*+,
"Particulate matter," also known as PM is made up of a number of components including AIRBORNE
extremely small particles and liquid droplets. Sized at less than 2.5 micrometers (PM2.5), DATA ON REMOVAL OF AIRBORNE BACTERIA WAS PRESENTED BY HARVARD SCHOOL OF PUBLIC HEALTH
RESEARCHERS AT NANO-SYMPOSIUM AT KYOTO UNIVERSITY, 2012
these particles are said to pose health problems as they can easily enter our lungs.
In a large space of 40 m³
Removal effect has been evaluated.
PARTICLE SIZE COMPARISON The effect after 100 minutes in a 40 m³ test space [about the size of a 10 September 2012 by Harvard University and Kyoto University.
POLLEN BACTERIA / FINE 1 tatami mat room], not the effect in a space where actually used. Test methods: Bacteria removal method: Release of nanoe-G ions.
MOULD PARTICLES Target: Airborne bacteria, Test results: It is estimated that after three hours
Size “Performance evaluation of a novel ionizer for air purification applications”. of operation the nanoe-G will achieve 2.7 log10 reductions, ~ 1 log10 reduction
POLLEN

C/Co (Normalized spore concentration)


(μm) Dr. S. Rudnick et al. Harvard School of Public Health, Environmental Health more, as compared to without nanoe-G.
PM2.5 10µm-100µm 0.1
Large Nanoscience Lab.
nanoe-G on
10µm nanoe-G off
nanoe-G
BACTERIA 0.01
1 log10 reduction A study of the removal effect of airborne bacteria by using an
1µm-10µm Experimental data Projection
air-conditioner incorporating nanoe-G was carried out in a large space,
DIAMETER 2.5µm and the results were presented at Nano-Symposium jointly held in
0.001
0 20 40 60 80 100 120 140 160 180
PM2.5 is found in
>10μm <10μm
<2.5μm VIRUS ∙ Industrial Smoke
time (min)

∙ Exhaust Gas
0.001µm-0.1µm ∙ Haze
∙ Cigarette Smoke
Small AIRBORNE
SOURCES OF PM2.5
TARGET SUBSTANCE EFFECTIVENESS TESTING TEST REPORT METHOD RESULT
PM2.5 can be found suspended in the air, including dust, SUBSTANCE NAME INSTITUTE NO
dirt, smoke and liquid droplets. These fine particles The AC with nanoe-G was
come from man-made sources such as the combustion PM2.5
Cigarette Smoke
(as PM2.5) 99%
FCG Research Test Report
operated in a test room (23m³) and
the concentration of PM2.5 was
99% removal from the
air after 202 minutes of
Institute, Inc No. 25034
of fossil fuels, open burning and industrial processes as measured by PM2.5 Digital Dust
Indicator.
operation.

well as natural ones, which include sea sprays and dust


Kitasato The AC with nanoe-G was
carried by strong winds. Staphylococcus
Research KRCES-Bio. operated in a test room (25m³) and 99% removal from the
Bacteria 99% Center for Test Report aerosol was collected and air after 150 minutes of
aureus (NBRC 12732)
Environmental 1RB bacterial count was calculated. operation.
Science
PM2.5 REMOVAL EFFICIENCY BASED ON TIME
Kitasato The AC with nanoe-G was
Research KRCES-Env. operated in a test room (25m³) and 99% removal from the
99% Center for Test Report airborne phages were collected air after 120 minutes of
SERIAL MEASUREMENT OF PM2.5 CONCENTRATION Legend: Environmental 1RB and phage count of the collected operation.
Science air was calculated.
2.0 Air conditioner with nanoe-G Escherichia coli phage
(øX-174 ATCC 13706-B1)
PM2.5 Concentration (mg/ m3)

1.8
Kitasato nanoe-G was operated in a test
1.6 Research KRCES-Env. chamber (200 Litre) and the 99% removal from the
1.4 99% Center for Test Report phages were collected and phage air after 5 minutes of
Environmental 1RB count of the collected air was operation.
1.2 80 min 202 min Science calculated.
1.0
0.8
90% removal 99% removal
nanoe-G was operated in a test
0.6 chamber (200 Litre) and the
influenza viruses were collected 99% removal from the
0.4 air after 5 minutes of
Virus and the virus titers were
0.2 operation.
calculated by the Reed and
0.0 Muench method.
0 30 60 90 120 150 180 210 240 270 300

Time Elapsed (min.)


Kitasato In view of health hazard associated with spatial distribution of
Research KRCES-Env. Influenza (H1N1) 2009 virus, nanoe-G removal effectiveness
Influenza (H1N1) 2009 Test Report
99% Center for cannot be tested in large test room (25m³). When tested in 200
virus
Environmental 1RB Litre chamber, nanoe-G was able to decrease Influenza (H1N1)
Science 2009 virus (99%) when it was operated for 5 minutes. Additionally
AIRBORNE when tested in larger test room (25m³), nanoe-G can remove
99.5% of Coli phage virus when operated for 120 minutes. It was
validated that evaluation on the influenza virus could be
*1 PM2.5 Removal was certified by FCG Research *² Airborne Removal was certified by Kitasato Research speculated from the results on the phage according to the test
Institute, Inc Center for Environmental Science
REMOVES REMOVES results in a 200 Litre test chamber. It appeared that the

99% 99%
í Test Report no. : 25034 í.5&(6%LR7HVW5HSRUWQRB air-conditioners in a larger test room (25m³) would be able to
UP TO *1 UP TO *2 Bacteria : Staphylococcus aureus (NBRC 12732)
PM2.5 : Cigarette Smoke (as PM2.5) remove the influenza virus as effectively as the phage.
Effectiveness is measured on 0.3μm-2.5μm. í .5&(6(QY7HVW5HSRUWQRB
PM2.5 BACTERIA Virus : Escherichia coli phage (øX-174 ATCC
(Specific size only)
VIRUSES 13706-B1) Kitasato The AC with nanoe-G was
This removal effect is not proven for all the and MOULD Research KRCES-Bio. operated in a test room (25m³) and 99% removal from the
: Influenza (H1N1) 2009 Virus Penicillium pinophilum
airborne toxic substances. Mould 99% Center for Test Report aerosol was collected and fungal air after 90 minutes of
í .5&(6(QY7HVW5HSRUWQRB (NBRC 6345) 1RB
All results are based on specific testing conditions. Mould : Penicillium pinophilum (NBRC 6345) Environmental spores count was calculated. operation.
All tests are not demonstrated under actual usage Science
All results are based on specific testing conditions.
situation.
All tests are not demonstrated under actual usage situation.

Remark: All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.

36 37
nanoe-G TECHNICAL EXPLANATION nanoe-G TECHNICAL EXPLANATION

ADHESIVE

ODOUR DEODORISATION: THE ODOUR ADHERED ON THE CURTAINS AND SOFA


!"#$%"&'$()*+(,-&.$%&/0-(1/-(")$#".23
5
Decrease in odour intensity by one level Odour Intensity Degree of Smell
after 2 hours of operation. 4.17
0 No odour 4
1 Barely able to detect

Odour Intensity
Test Subject: Adhesive smell of tobacco smoke 3.25
(detection threshold) 1 Level Down
Test Chamber: 20m³ 2 Able to recognise a smell,
3

Measurement Method: Six-level odour intensity but weak (recognition threshold)


2.25
indication method 3 Easily perceptible
2
Natural AC with
Test report No.: 13-1204 4 Strong
1
Decay nanoe-G 1. POWER “OFF” 2. FAN OPERATION 3. nanoe-G OPERATION 4. DEACTIVATION EFFECT
5 Very Strong

0
The air-conditioner first The fan operation will run Natural Ion Wind spreads nanoe-G deactivates bacteria
Initial After 2 hours
has to be turned off. automatically for 30 minutes with the nanoe-G particles that are and viruses that are trapped in
flaps slightly open to ensure the released from the nanoe-G the filter within 2 hours.
internal components are dry and free generator.
from condensation.
ADHESIVE Remark: Remark: Remark:
Main power must be switched The 30-minute fan operation is only applicable Depending on the Air Conditioner’s accumulated operation time, nanoe-G In-Filter
on for the entire duration. when the unit has been operated in COOL /DRY Deactivation may be activated only once a day.
TARGET SUBSTANCE TESTING TEST
EFFECTIVENESS METHOD RESULT mode.
SUBSTANCE NAME INSTITUTE REPORT
NO
Fan Operation : On Fan Operation : Off
Flap : Flaps slightly open Flap : Closed
The AC with nanoe-G was operated 99% inactivation after 24 nanoe-G LED : On nanoe-G LED : On
Staphylococcus Japan Food Test Report in a test space (10m³) and viable hour operation of
Bacteria aureus 99% Research No. cells were counted by pour plate nanoe-G. (compared to the
(NBRC 12732) Laboratories 11047933001-02 method. original condition/
ventilation mode) IN-FILTER DEACTIVATION

TARGET SUBSTANCE EFFECTIVENESS TESTING TEST METHOD RESULT


Bacteriophage Japan Food Test Report nanoe-G was operated in a test box 99% inactivation after 120 SUBSTANCE NAME INSTITUTE REPORT
Virus (Phi X 174 99% Research No. (90 Litre) and phage infectivity titer minutes operation of NO
NBRC 103405) Laboratories 11073649001-02 was determined by plaque nanoe-G. (compared to
technique. non-operation)
The test piece impregnated with Staphylococcus aureus was placed on 99% of deactivation
Staphylococcus Japan Food Test Report the filter of the Air Conditioner indoor unit, and then nanoe-G was after 2-hour
Bacteria aureus 99% Research No. 12037932001 operated. After the test piece was collected, viable cells were counted. nanoe-G
(NBRC 12732) Laboratories * test substance was placed on the 4 locations of the filter; upper/lower operation.
right and upper/lower left.
Cladosporium Inhibit Japan Food Test Report nanoe-G was operated in a test box The growth of the subject
Mould cladosporioides Mould Research No. (1m³) and colonies on the plate was inhibited.
(NBRC 6348) Growth Laboratories 11047937001-02 were counted. (>85% after 7 days) The test piece impregnated with Escherichia coli phage was placed on
99% of
Escherichia the filter of the Air Conditioner indoor unit, and then nanoe-G was
Japan Food deactivation
coli phage Test Report operated. After the test piece was collected, phage infectivity titer was
99% Research after 2-hour
(øX-174 ATCC No. 12014705001 determined.
Laboratories nanoe-G
13706-B1) * test substance was placed on the 4 locations of the filter; upper/lower
operation.
The AC with nanoe-G was operated right and upper/lower left.
in a test room (20m³) and the
OMI deodorisation effect on a piece of Decrease in odour The test piece impregnated with Influenza (H1N1) 2009 Virus was placed Average 90%
Smell of Average 90% on Kitasato KRCES-Virus
Decrease by ODOR-AIR Test Report cloth impregnated with odour intensity by one level after Virus Influenza on the filter of the Air Conditioner indoor unit, and then nanoe-G was deactivation after
Odour tobacco filter (The Research Test Report
one level SERVICE No. 13-1204 components of cigarette smoke 120 minutes of operation. (H1N1) 2009 operated. After the test piece was collected, virus infectivity titer was 2-hour nanoe-G
smoke percentage varies Center for No. 24_0013
Co.Ltd. was evaluated using six-level Virus determined. operation.
from 78.9% to Environmental
odour intensity indication method. 96.1% depending Science * test substance was placed on the 4 locations of the filter; upper/lower (The percentage
on its location) right and upper/lower left. varies from 78.9% to
96.1%, depending on
its location on filter)
Remark: All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
Remark: All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.

ADHESIVE ADHESIVE ODOURS IN-FILTER DEACTIVATION

*³ Adhesive Deactivation was certified by Adhesive odour deodorisation was certified by


DEACTIVATES Japan Food Research Laboratories OMI ODOR-AIR SERVICE Co. Ltd. DEACTIVATES DEACTIVATES
DEODORISES

99% 99%
UP TO *3 UP TO *4 AVERAGE

90%
í7HVW5HSRUWQXPEHU
Bacteria : Staphylococcus aureus (NBRC 12732) ADHESIVE ODOUR í7HVW5HSRUW1R
UP TO
BACTERIA í7HVW5HSRUWQXPEHU All results are based on specific BACTERIA
and VIRUSES Virus : Bacteriophage (Phi X 174 NBRC 103405) (TOBACCO SMELL) testing conditions. and VIRUSES INFLUENZA
í7HVW5HSRUWQXPEHU All tests are not demonstrated under actual (H1N1)
INHIBITS MOULD GROWTH usage situation. INHIBITS MOULD GROWTH
Mould : Cladosporium cladosporioides (NBRC 6348) 2009 VIRUS

All results are based on specific testing conditions.


All tests are not demonstrated under actual usage situation. In-Filter Deactivation was certified by Kitasato
*⁴ In-Filter Deactivation was certified by Japan Food Research Laboratories
Research Center for Environmental Science
í7HVW5HSRUWQXPEHU
í7HVW5HSRUWQXPEHU.5&(69LUXV7HVW5HSRUW
Bacteria : Staphylococcus aureus (NBRC 12732)
No. 24_0013
í7HVW5HSRUWQXPEHU Virus : Influenza (H1N1) 2009 Virus
Virus : Escherichia coli phage (φΧ-174 ATCC 13706-B1) All results are based on specific testing conditions.
All results are based on specific testing conditions. All tests are not demonstrated under actual usage
situation.
All tests are not demonstrated under actual usage situation.

38 39
iAUTO-X TECHNICAL EXPLANATION iAUTO TECHNICAL EXPLANATION

)-+!$"%&'';*4< !"#$%&'()'"!
*+%,#+!%-%!'#&.%-/-0
iAUTO-X cools you down 35% faster compared to

35 %*
Panasonic Standard non-Inverter model with high fan.
Room Temperature SINE WAVE DRIVE 1. FAST COOLING
AT START UP
35ºC Faster Cooling iAUTO utilises high efficient Sine Wave DC motor to
realise both powerful cooling and energy saving. At start up, iAUTO will run at
* Comparison of 1.5HP PREMIUM Inverter super high fan speed to cool
with iAUTO-X mode and Standard
non-Inverter model with cooling mode the room faster, 15% faster
SINE WAVE COMPARISONS
PREMIUM Inverter: iAUTO-X Mode for cooler comfort.
29ºC iAUTO-X Mode, Outside Temperature: 35˚C
/24˚C

Quick Remote setting temperature: 25˚C with Fan


Speed: Auto
Horizontal Airflow direction: Auto, Vertical
Airflow direction: Straight Sine Wave drive produces smooth wave
curves.This reduces power loss or
2. MAINTAIN
25ºC Standard non-Inverter: Cooling Mode with energy waste.
High Fan
COOL Mode, Outside Temperature: 35˚C Sine Wave (blue)
COOLING COMFORT
/24˚C curves smoothly Conventional rectangle drive produces
Remote setting temperature : 25˚C with Fan
Speed: High
compared to conventional distortions which results in power Once the room cools down,
Horizontal Airflow direction: Auto, Vertical rectangle (grey) efficiency loss.
Time Airflow direction: Straight iAUTO provides constant
cool airflow to maintain a
PREMIUM Inverter with iAUTO-X The time to reach the setting temperature
was measured. comfortable level of relative
At Panasonic Amenity Room (size: 16.6m²)
Standard non-Inverter model with The effect differs according to conditions in humidity, to stay cool
high fan installation and usage.
ADVANTAGES OF SINE WAVE
and comfortable all day
1. EFFICIENCY UP EVEN AT MOTOR EFFICIENCY DATA (EX. INDOOR UNIT) long.
HIGH ROTATIONAL SPEED PER MINUTE (RPM) 80

75

-#!'(-!*&%)-4%+9$$:
3. AUTOMATIC FAN SPEED

Efficiency (%)
Reduced current distortion enables fan motor to start faster, 70

65

run cooler and perform more efficiently even while running


iAUTO automatically
60
300 500 700 900 1100 1300 1500

at super high fan speed to help reduce power consumption. Speed (r/min)

switches fan speed to high


iAUTO-X will automatically switch fan speed CONVENTIONAL COOLING FAST COOLING Legend: Sine Wave Conventional rectangle

and super high fan speed


to high fan speed and super high fan speed 2. STABLE OPERATION depending on
depending on the temperature difference Sine Wave regulates power voltage that is identical to power supplied, ensuring consistent the temperature difference
performance and stable operation. between the room
between the room and the set temperature.
and the set temperature.

3. LOW VIBRATION
LOW SPEED Motor loads run smoother with low vibrations resulting in quieter operation.
warmer cooler

MEDIUM SPEED QUALITY CONTROL THROUGH SIMULATED LABORATORY TEST


FASTER
COOLING
Panasonic carried out testing at our own Environmental
HIGH FAN SPEED Testing Room which simulates a standard living room
* Comparison of 1.5HP DELUXE Non-INVERTER model
condition. This makes it possible to ensure the with iAUTO Mode and Cooling Mode

air conditioner operates at optimum performance level 123%+$4+'"+ iAUTO Mode


iAUTO Mode, Outside Temperature: 35°C / 24°C
SUPER HIGH FAN SPEED under varying conditions.
Remote setting temperature: 25˚C with Fan Speed: Auto
Horizontal Airflow direction: Middle, Vertical Airflow
156578 direction: Straight

Remark: Cooling Mode with High Fan


Applicable for PREMIUM Inverter with iAUTO-X COOL Mode, Outside Temperature: 35˚C/24˚C
Remote setting temperature: 25˚C with Fan Speed: High
Horizontal Airflow direction: Middle, Vertical Airflow
Testing is done in a large space of 16.6m² to simulate the size of an actual living room. direction: Straight

Indoor temperature is measured using 150 sensors to get the average room temperature. Total power consumption amount is measured
for 2 hours under stable operation.
This ensures the accuracy of indoor temperature data. At Panasonic Amenity Room (size: 16.6m²)
The effect differs according to conditions
in installation and usage.

*Applicable to PREMIUM INVERTER only. *Applicable to STANDARD INVERTER, STANDARD Non-INVERTER & DELUXE Non-INVERTER.

40 41
FEATURES COMPARISON FEATURES COMPARISON

FEATURES COMPARISON

Split Type ELITE Inverter PREMIUM Inverter STANDARD Inverter DELUXE Low Watt Low Watt STANDARD Non-Inverter Low Voltage

Wall-Mounted

CS-VU10SKP CS-U10TKP CS-U18TKP CS-PU9TKP CS-PU18TKP CS-XN5SKJ CS-KN5SKJ CS-PN5SKJ CS-PN18SKP CS-YN5SKJ CS-UV5SKP
CS-VU13SKP CS-U13TKP CS-U24TKP CS-PU12TKP CS-PU24TKP CS-XN7SKJ CS-KN7SKJ CS-PN7SKJ CS-PN24SKP CS-YN7SKJ CS-UV9SKP
CS-VU18SKP CS-XN9SKJ CS-KN9SKJ CS-PN9SKJ CS-YN9SKJ
CS-PN12SKJ
Cooling Models

COMFORT

RADIANT COOLING
Radiant Cooling

iCOMFORT

iAUTO-X

SLEEP SLEEP

Inverter Control

iAUTO

Quiet Mode

Powerful Mode

Soft Dry Operation


Mode

Personal Airflow
Creation

Airflow Direction
Control (Up & Down)

Airflow Direction Control


(Left & Right)

Manual Horizontal
Airflow Direction
Control

Automatic Operation
Mode (Cooling)

CLEANER AIR

nanoe-G

Anti-Dust Coating

Anti-Bacterial Filter

DUST SENSOR
Dust Sensor

Odour-Removing
Function

Removable,
Washable Panel

CONVENIENCE
24-Hour Dual
ON & OFF
Real Setting Timer

24-Hour
ON & OFF Real
Setting Timer

12-Hour On & Off Setting


Timer

LCD Wireless
Remote Control

Wired Remote
Control (Optional) (Optional) (Optional) (Optional) (Optional)

RELIABILITY
Random Auto Restart
(32 Restart Patterns)
(Random)

Blue Fin Condenser

Long Piping (Numbers


indicate the maximum 20m (VU10/13) 20m 30m 20m 30m (PU18) 30m
pipe length) 30m (VU18) 20m (PU24)

Top-Panel
Maintenance Access

Self-Diagnostic
Function

42 43
FEATURES EXPLANATION ACCESSORIES

FEATURES EXPLANATION OPTIONAL ACCESSORIES


COMFORT REMOTE CONTROL

RADIANT COOLING iAUTO AIRFLOW DIRECTION CONTROL


Cools the ceiling and walls first, providing RADIANT COOLING Automatic Intelligence switches fan speed for (UP & DOWN) Wired Remote Control
continuous cooling comfort without direct faster cooling with just one touch of a button.
airflow.

iCOMFORT QUIET MODE


Let you come home to fast cooling. Then enjoy AIRFLOW DIRECTION CONTROL
continuous comfort with RADIANT COOLING which
avoids direct cooling. (LEFT & RIGHT)

CZ-RD514C
iAUTO-X POWERFUL MODE
Come home to fast cooling. Then enjoy
continuous comfort with Shower Cooling which MANUAL HORIZONTAL
avoids direct cooling.
AIRFLOW DIRECTION CONTROL CS-VU10SKP, CS-VU13SKP, CS-VU18SKP
SOFT DRY OPERATION MODE CS-U10TKP, CS-U13TKP, CS-U18TKP, CS-U24TKP
Starts with cooling to dehumidify, then provides CS-PU9TKP, CS-PU12TKP, CS-PU18TKP, CS-PU24TKP
SLEEP MODE continuous breeze at a low frequency to keep a
Delays off timer with temperature control SLEEP room dry without much change to the temperature.
for better sleep.
AUTOMATIC OPERATION MODE

INVERTER CONTROL PERSONAL AIRFLOW CREATION


Vertical and horizontal airflow patterns can be
Varies the rotation speed of the compressor for
combined as desired to achieve optimum comfort,
higher energy savings.
with operation possible by remote even from a
distance.

CLEANER AIR

nanoe-G ANTI-DUST COATING ODOUR-REMOVING FUNCTION


nanoe-G works effectively on airborne particles Anti-dust coating prevents dust from With this function, there's no unpleasant odor when
including PM2.5, adhesive and in-filter accumulating on cross flow fan by the unit starts up. That's because the fan remains off
micro-organisms such as bacteria, viruses and keeping it clean. momentarily, while the source of the odour inside the
mould ensuring a cleaner living environment. air conditioner is suppressed.

The unit must be in cool or dry mode and the fan speed
must be set to automatic.
DUST SENSOR ANTI-BACTERIAL FILTER
Monitors particle concentration levels and DUST SENSOR The Anti-Bacterial Filter combines three effects
turns on nanoe-G if levels are high. in one: anti-allergen, anti-virus and anti-bacteria REMOVABLE, WASHABLE
protection to provide clean air. PANEL

CONVENIENCE

24-HOUR DUAL ON & OFF 24-HOUR ON & OFF LCD WIRELESS REMOTE
REAL SETTING TIMER REAL SETTING TIMER CONTROL
This feature enables you to preset two different The exact operating time (hour and minute) of the air
sets of start/stop operation timer (hour and conditioner can be set in advance. From here on, the
minute) within a 24-hour time frame. unit will operate in accordance to these preset hours
every day until the system is reset.

12-HOUR ON & OFF SETTING WIRED REMOTE CONTROL


TIMER

RELIABILITY

RANDOM AUTO RESTART SELF-DIAGNOSTIC FUNCTION LONG PIPING


Should a malfunction occur, the unit
(Random) diagnoses the problem and shows the
corresponding alphanumeric code. This
allows for quicker servicing.

BLUE FIN CONDENSER TOP-PANEL MAINTENANCE


ACCESS

44 45
MODEL LINE-UP MODEL LINE-UP

Capacity (Btu/h) 5,000/7,000 9,000 10,000 12,000 13,000 18,000 24,000


ELITE INVERTER ELITE INVERTER WIDE FEATURES

Wall-Mounted
ELITE
INVERTER
Page 22-23
CS-VU10SKP CS-VU13SKP CS-VU18SKP
(CU-VU10SKP) (CU-VU13SKP) (CU-VU18SKP) (CS-VU10SKP)

PREMIUM INVERTER PREMIUM INVERTER WIDE FEATURES

Wall-Mounted
PREMIUM
INVERTER
Page 24-25 CS-U10TKP CS-U13TKP CS-U18TKP CS-U24TKP
(CU-U10TKP) (CU-U13TKP) (CU-U18TKP) (CU-U24TKP)

STANDARD INVERTER STANDARD INVERTER WIDE FEATURES

Wall-Mounted
STANDARD
INVERTER
Page 26-27 CS-PU9TKP CS-PU12TKP CS-PU18TKP CS-PU24TKP
(CU-PU9TKP) (CU-PU12TKP) (CU-PU18TKP) (CU-PU24TKP)

DELUXE LOW WATT DELUXE LOW WATT WIDE FEATURES

XN MODEL
Wall-Mounted
DELUXE
LOW WATT
Page 28

LOW WATT LOW WATT WIDE FEATURES

KN MODEL
Wall-Mounted
LOW WATT
Page 29

STANDARD NON-INVERTER STANDARD NON-INVERTER WIDE FEATURES

PN MODEL
Wall-Mounted
STANDARD
NON-INVERTER
Page 30

STANDARD STANDARD WIDE FEATURES

Wall-Mounted
STANDARD
NON-INVERTER CS-PN18SKP CS-PN24SKP
Page 31 (CU-PN18SKP) (CU-PN24SKP)

STANDARD STANDARD WIDE FEATURES

YN MODEL
Wall-Mounted
STANDARD
NON-INVERTER
Page 32

LOW VOLTAGE LOW VOLTAGE WIDE FEATURES

UV MODEL
Wall-Mounted
LOW VOLTAGE
Page 33

( ): Outdoor Unit Cooling Models

46 47

You might also like