2017/2018
ELITE INVERTER
N E W P R E M I U M I N V E RT E R
Please read the Installation Instructions carefully before installing the unit,
and the Operating Instructions before using it.
Specifications are subject to change without prior notice.
The contents of this catalogue are accurate as of January 2017.
Due to printing considerations, the actual colours may vary slightly from those shown.
All graphics are provided merely for the purpose of illustrating a point.
AC-IND-C-17
CONTENTS KAI KEN BI
!"#$%#$& $'%()'*+"&")',("-().#.&"#*!
02 - 03 20 - 21
At Panasonic, air conditioning is more than just about cool air.
KAI KEN BI INVERTER It is about how cool air is delivered to create a living space that
brings you comfort when you need it most, takes care of
04 - 05 22 - 33 your health and beautifies your homes and lives.
#AIRTHATMOVESYOU PRODUCT LINE-UP
DIRECT & INDIRECT COOLING
34 - 35
06 - 07 RADIANT COOLING
SKY SERIES TECHNICAL EXPLANATION KAI KEN
08 - 09 36 - 39
AERO SERIES nanoe-G
TECHNICAL EXPLANATION
10 - 11
DIRECT COOLING 40 - 41
-SKY SERIES iAUTO-X & iAUTO
TECHNICAL EXPLANATION BI
12 - 13
DIRECT COOLING 42 - 43
-AERO SERIES FEATURES COMPARISON
14 - 15 44 - 45
INDIRECT COOLING FEATURES EXPLANATION
-SKY SERIES COMFORT
& ACCESSORIES
Essential air conditioner functions
KAI that cool you in a more natural way.
16 - 17 46 - 47
INDIRECT COOLING MODEL LINE-UP
-AERO SERIES HEALTH
02 04
02 03
#AIRTHATMOVESYOU DIRECT COOLING & INDIRECT COOLING
!"#$%&'()*%+',-
Is it the uplifting feeling of a cool gentle breeze? For the perfect cooling experience,
Or is it the exhilarating blast of cool air on a hot day? Panasonic Air Conditioners are designed
to deliver comfort through Direct Cooling
Experience cooling comfort inspired by nature with
and Indirect Cooling.
Panasonic SKY Series and AERO Series.
INDIRECT COOLING
NEW
04 04 05
SKY SERIES SKY SERIES
ELITE INVERTER
A I R CO N D I T I O N E R
!"#.+-,
6.<:,1*LVDQLQQRYDWLYHWRSIODSWKDWFDQEHWWHUGLUHFW
FRRODLUWRZDUGVWKHFHLOLQJ7KHFRRODLUWKHQQDWXUDOO\
glides along the ceiling surface, spreading throughout
the room and down the walls. Heat is removed
from the ceiling and walls, resulting in a feeling of even,
DOOURXQGFRROQHVVä5$',$17&22/,1*
!"#$!%&'()$*'!+,-
MODERN & MINIMALIST SLIDING LED PANEL BACKLIT FAST COOLING RADIANT COOLING
LINES SKY CONTROLLER SKYWING angles downwards After reaching the set temperature,
î6OHHNDQGVWULNLQJGHVLJQ î:KHQVZLWFKHGRQ î%DFNOLW/('6FUHHQ to deliver powerful airflow SKYWING angles upwards to direct
î/X[XULRXVFRPSOHPHQW the panel slides open î'LVWLQFWLYH6OLGLQJ&RYHU at start up. cool air towards ceiling and walls,
to designer interior. to reveal its setting î3UHFLVH7HPSHUDWXUH spreading cool air evenly
Please refer to Pg10-11
indicators. &RQWURO$GMXVWDEOHDW throughout the room.
r&
Please refer to Pg14-15
06 07
AERO SERIES AERO SERIES
N E W P R E M I U M I N V E RT E R
AIR CONDITIONER
!"#$-(,+&
AEROWINGS are flexible twin flaps that can direct and
FRQFHQWUDWHDLUIORZWRFRRODQDUHDHIIHFWLYHO\7KHVHIODSV
are able to channel and concentrate cool air upwards,
which showers down over the room for gentle
DQGHYHQFRROQHVVä6+2:(5&22/,1*
!"#$%&'()%*"&(+,
236mm 199mm
SLIM & SLEEK OUTLINE LUSTROUS PEARL AERO CONTROLLER FAST COOLING SHOWER COOLING
FINISHING AEROWINGS twin flaps AEROWINGS angles upwards to
îPPVOLPPHUWKDQ î&ODVV\WRQHZLWKDVRIW î3UHFLVH7HPSHUDWXUH angle downwards to deliver spread cool air over a wider area,
previous models. pearly glow. Control - Adjustable at concentrated airflow to cool then showers down gently
î&KURPHHVFXWFKHRQZLWK 0.5°C. you instantly at start up. and evenly across the room after
a sense of luxury. reaching the set temperature.
*AEROWINGS now available across all models. Design may vary according to models.
08 09
DIRECT COOLING - SKY SERIES DIRECT COOLING - SKY SERIES
ELITE INVERTER
A I R CO N D I T I O N E R
!"#$%&'%(()"*+
,(-$#./)'.01&'%(()"*+
.223'&42'&45633678'%993'-67:
At start up, SKYWING tilts down to bring you powerful and direct airflow
to cool down instantly. Together with the high-powered Inverter compressor
technology, P-TECh, SKY Series can achieve the desired temperature
in the shortest time possible.
.(#';(/#' 2
$*<(;=$*&
î&RROV<RX'RZQ
Instantly At Start Up P-TECh enables the compressor to achieve warmer cooler
maximum frequency in the shortest time
SKYWING directs CONVENTIONAL FAST COOLING
from start up, giving you powerful cooling
airflow downwards COOLING
the moment the air conditioner is switched on.
and straight to Cool air blows Powerful airflow
DASH & HIGH COMPRESSOR FREQUENCY room occupants for downwards and cools cools rapidly.
Y
2017 Panasonic a fast cooling effect.
EQUENC
the room at a slow Room is evenly cooled.
P-TECh
pace, resulting in
MAX FR
2014 Panasonic
uneven cooling.
DASH TO
The edge of the room
remains warm.
Time (min.)
10 11
DIRECT COOLING - AERO SERIES DIRECT COOLING - AERO SERIES
N E W P R E M I U M I N V E RT E R
AIR CONDITIONER
2.%$-,)-""(./0
!"#$%&'()&*+,)-""(./0
#.,1)-"/-$/,%*,$2)*.%&("#
34)0544647)#869)*)3:;<6)"= )->>:)*85
î,QVWDQW5HOLHI
From The Heat P-TECh enables the compressor to achieve warmer cooler
maximum frequency in the shortest time
AEROWINGS directs CONVENTIONAL FAST COOLING
from start up, giving you powerful cooling
airflow downwards COOLING
the moment the air conditioner is switched on.
and straight to Cool air blows Concentrated airflow
DASH & HIGH COMPRESSOR FREQUENCY room occupants for downwards and cools cools instantly.
Y
2017 Panasonic a fast cooling effect.
EQUENC
the room at a slow Room is evenly cooled.
P-TECh
pace, resulting in
MAX FR
2014 Panasonic
uneven cooling.
DASH TO
The edge of the room
remains warm.
Time (min.)
12 13
INDIRECT COOLING - SKY SERIES INDIRECT COOLING - SKY SERIES
ELITE INVERTER
A I R CO N D I T I O N E R
$%#$!;(&'())*$%+
!"#$"%&'())*$%+
#,-./012'%345236'"667!/589'(//6,8:
4 Room is evenly
cooled down.
How RADIANT COOLING works:
î &RROLQJ(IIHFW
Inspired By Caves
warmer cooler
That Prevents Instead of blowing RADIANT COOLING Hot air is drawn in
([FHVVLYH&RROLQJ cold air directly onto SKYWING directs from the bottom,
people, SKYWING cool air upwards, and cool air is
directs the airflow removing heat from discharged from
î 6NLQ6WD\V upwards to cool ceiling and walls the top to facilitate
the ceiling and walls. for an all-round the even distribution
Moist And Supple cooling effect. of cool air.
14 15
INDIRECT COOLING - AERO SERIES INDIRECT COOLING - AERO SERIES
N E W P R E M I U M I N V E RT E R
AIR CONDITIONER
*+8*&%(='(##)*+,
!"#$%&'(##)*+,
-../',.01/.'(22/')34.'5260307'8.9
2 Cool air
2
spreads evenly
(:&%! and showers down.
3
-#&';#<&' Room is evenly
3
(#5-#&= cooled down.
î3UHYHQWV2YHUFRROLQJ
From Direct Airflow warmer cooler
16 17
AIR PURIFICATION SYSTEM AIR PURIFICATION SYSTEM
".#&1*#.'.!"2.(/
%)%2$3 -9567>5&'95?>&@&!A56;
)RURYHUDOOZHOOEHLQJ3DQDVRQLF$LU&RQGLWLRQHUVIHDWXUH
DQDGYDQFHGDLUSXULILFDWLRQV\VWHPFDOOHGQDQRHG
ZKLFKUHOHDVHVDFWLYHLRQVWKDWDWWDFKWRSDUWLFOHVDVVPDOODV30
How nanoe-G works:
1 AIRBORNE
Airborne particles:
Natural Ion Wind 3 trillion*
PM2.5
Bacteria Viruses Mould
spreads nanoe-G nanoe-G
fine particles that fine particles
are released from released from the
+$,,-$./0 Mechanism
Odour Particle nanoe-G
nanoe-G catches
airborne particles
3 the mentioned conditions. Actual
measured nanoe-G fine particles
at the centre of the room
(13m2):100k/cc calculated number
of nanoe-G fine particles in the
ADHESIVE
2
entire room assuming they are
evenly distributed.
Strike Odour Particles Decompose and Remove Odour
1 2 3
REMOVES DEACTIVATES ADHESIVE IN-FILTER DEACTIVATION
AIRBORNE PARTICLES PARTICLES & DEODORISES (Up to 99%*4)
(Up to 99%*1 *2) ADHESIVE ODOURS
(Up to 99%*3) 'HDFWLYDWHVEDFWHULDDQG
5HPRYHVDLUERUQHSDUWLFOHV YLUXVHVWUDSSHGLQWKHILOWHU
HYHQGRZQWR30*1 'HDFWLYDWHVDGKHVLYH 3OHDVHUHIHUWR3J
*4
456789:;< &=*%2&%$/%(#
*Only applicable to SKY Series.
6.<6HULHVDOVRIHDWXUHVDQDGGLWLRQDO'8676(1625
ZKLFKFRQVWDQWO\PRQLWRUVDLUTXDOLW\DQG
DXWRPDWLFDOO\DFWLYDWHVQDQRHGZKHQDKLJKOHYHO
RISDUWLFOHFRQFHQWUDWLRQLVGHWHFWHG
18 19
INVERTER INVERTER
$.$#0)(%"1-.0%
6DYHVHQHUJ\E\DOWHUQDWLQJFRPSUHVVRUVSHHG +9:;<4:(=:7>:965?9:(!23592@
,19(57(5SUHYHQWVZDVWHIXOHQHUJ\FRQVXPSWLRQE\YDU\LQJ
WKHFRPSUHVVRUURWDWLRQVSHHGWRPDLQWDLQWKHVHWWHPSHUDWXUH
NON-INVERTER
Room Big temperature
temperature fluctuations
$FRQYHQWLRQDOQRQ,19(57(5DLUFRQGLWLRQHU
Set
temperature FDQRQO\RSHUDWHDWDFRQVWDQWVSHHGZKLFKLVWRR
SRZHUIXOWRPDLQWDLQWKHVHWWHPSHUDWXUH7KXVLW
Output power
VZLWFKHVWKHFRPSUHVVRURQDQGRIIUHSHDWHGO\
ON OFF ON OFF ON
7KLVUHVXOWVLQZLGHUWHPSHUDWXUHIOXFWXDWLRQV
Time
OHDGLQJWRZDVWHIXOFRQVXPSWLRQRIHQHUJ\
!"#$% Legend: Output Power Temperature
&'#()'*#(
Remark: Energy is wasted by switching the compressor
ON and OFF to maintain the set temperature.
+$"!$('&(,-./ INVERTER
Output power
Set temperature
7KXV3DQDVRQLF,19(57(5DLUFRQGLWLRQHUVJLYH
ON
\RXH[FHSWLRQDOHQHUJ\VDYLQJSHUIRUPDQFHZKLOH
Time
HQVXULQJ\RXVWD\FRPIRUWDEOHDWDOOWLPHV
Legend: Output Power Temperature
Remark: Saves energy by varying the rotation speed of the
compressor to maintain the set temperature.
î 6WD\&RPIRUWDEOH !2345635(!278295
:KLOH6DYLQJ(QHUJ\
3UHFLVHWHPSHUDWXUHFRQWUROZLWKDZLGHSRZHURXWSXWUDQJHHQDEOHVDQ
,19(57(5DLUFRQGLWLRQHUWRPHHWGLIIHUHQWURRPRFFXSDQF\OHYHOVäWKXV
î 3UHFLVH7HPSHUDWXUH HQVXULQJFRQVWDQWFRPIRUW
&RQWURO
MAXIMUM POWER MEDIUM POWER MINIMUM POWER
î6DYHRQ
(OHFWULFLW\%LOOV
Compressor rotation speed: HIGH Normal condition Compressor rotation speed: SLOW
When required, the unit operates When not required, the unit operates
at full power. at low power to save energy.
Power: 4.20kW Power: 3.67kW Power: 0.92kW
Graph shows the 1.5HP PREMIUM INVERTER model’s wide power output range during cooling.
20 21
PRODUCT LINE-UP PRODUCT LINE-UP
Indoor (H / L / Q-Lo) dB (A) 36/25/18 - 36/25/18 41/27/19 - 41/27/19 46/36/33 - 46/36/33 which avoids direct cooling. 1
Noise Level
Outdoor (H / L) dB (A) (47) - (48) (48) - (49) (49) - (49)
mm 318 (511) 318 (542) 318 (619) 4 Press up or down to set the 2
Height temperature. 3
inch 12-17/32 (20-1/8) 12-17/32 (21-11/32) 12-17/32 (24-3/8) 4 OUTDOOR
mm 950 (650) 950 (780) 950 (824) Toggles between RADIANT COOLING 5
Dimensions Width 5
inch 37-13/32 (25-19/32) 37-13/32 (30-23/32) 37-13/32 (32-15/32) (INDIRECT) and Fast Cooling (DIRECT).
7
*The term “RADIANT” was replaced based on 6 8
mm 280 (230) 280 (289) 280 (299)
Depth running change effective for new 2017 production.
inch 11-1/32 (9-1/16) 11-1/32 (11-13/32) 11-1/32 (11-25/32)
9 10
Indoor kg (lb) 13 (29) 13 (29) 13 (29) 6 Activates the nanoe-G even when CU-VU10SKP
Net Weight
Outdoor kg (lb) 21 (46) 29 (64) 33 (73)
the air conditioner is switched off.
11
mm ø 6.35
Liquid Side 7 Set the airflow.
Refrigerant Pipe inch 1/4
12
Diameter mm ø 9.52 ø 12.70
Gas Side 8 Adjusts the fan speed.
inch 3/8 1/2 CU-VU13SKP
Chargeless Pipe Length m 7.5 10
9 Toggles between COOL and DRY
Maximum Pipe Length m 20 30 setting mode.
Pipe Extension
Maximum Elevation Length m 15 20
CU-VU18SKP
11 Set the 24-hour ON & OFF Timer or
Caution For CS-VU10/VU13/VU18SKP (Important) Please do not use copper pipes that are less than 0.6mm in thickness.
*When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit. 24-hour Dual ON & OFF Timer.
Wireless
Applicable to ELITE Inverter
22 23
PRODUCT LINE-UP PRODUCT LINE-UP
SPECIFICATIONS Cooling ( ): Outdoor Unit 3 Toggles between iAUTO, COOL and COOLING MODELS
DRY setting mode. 1
MODEL (50Hz) CS-PU9TKP CS-PU12TKP CS-PU18TKP CS-PU24TKP
[CU-PU9TKP] [CU-PU12TKP] [CU-PU18TKP] [CU-PU24TKP] 4 Press up or down to set the
(min-max) kW 2.50 (0.84 - 2.73) 3.50 (0.92 - 4.00) 5.20 (1.10 - 5.80) 6.10 (1.12 - 6.90) temperature.
Cooling Capacity 2 SLEEP
(min-max) Btu/h 8,530 (2,860 - 9,310) 11,900 (3,140 - 13,600) 17,700 (3,750 - 19,800) 20,800 (3,820 - 23,500) CS-PU9TKP CS-PU18TKP
5 Delays off timer with temperature 4 CS-PU12TKP CS-PU24TKP
EER (min-max) Btu/hW 12.36 [12.17 - 11.22] 12.02 [11.63 - 11.33] 12.29 [12.50 - 11.58] 11.95 [11.58 - 10.68] control for better sleep. 3
Voltage V 220
CS-PU9TKP (Random)
Electrical Data Current A 3.4 4.8 6.9 8.3 6 Quiet function allows you to sleep 5
CS-PU12TKP
comfortably at night. 8
Power Input (min-max) W 690 (235 - 830) 990 (270 - 1,200) 1,440 [300 - 1,710] 1,740 (330 - 2,200) 7
20m 30m
L/h 6
1.5 2.0 2.9 3.4 (Optional) CS-PU9TKP CS-PU18TKP
Moisture Removal 7 Adjusts the fan speed. CS-PU12TKP
CS-PU24TKP
(Pt/h) 3.2 4.2 6.1 7.2
Indoor m3/min (ft3/min) 9.9 10.9 17.7 18.1 9
Air Circulation
8 Set the airflow.
Outdoor m3/min (ft3/min) 350 385 625 640
Indoor (H / L / Q-Lo) dB (A) 36/26/23 38/28/25 44/32/29 45/36/31 9 Set the 24-hour ON & OFF Timer or 10
Noise Level
Outdoor (H / L) dB (A) 46 47 49 51
24-hour Dual ON & OFF Timer.
mm 296 (511) 296 (542) 296 (619) 296 (695)
OUTDOOR
Height 10 Set the actual time (hour and
inch 11-21/32 (20-1/8) 11-21/32 (21-11/32) 11-21/32 (24-3/8) 11-21/32 (27-3/8) minute).
mm 870 (650) 870 (780) 1,070 (824) 1,070 (875)
Dimensions Width
inch 34-9/32 (25-19/32) 34-9/32 (30-23/32) 42-5/32 (32-15/32) 42-5/32 (34-15/32)
Wireless CU-PU9TKP
mm 236 (230) 236 (289) 241 (299) 241 (320)
Depth Applicable to CS-PU18/24TKP
inch 9-5/16 (9-1/16) 9-5/16 (11-13/32) 9-1/2 (11-25/32) 9-1/2 (12-5/8)
Indoor kg (lb) 9 (20) 9 (20) 12 (26) 12 (26)
Net Weight
Outdoor kg (lb) 20 (44) 27 (60) 33 (73) 46 (101)
mm ø 6.35
Liquid Side CU-PU12TKP
Refrigerant Pipe inch 1/4
Diameter mm ø 9.52 ø 12.70 ø 15.88
Gas Side TO SET THE TIMER
inch 3/8 1/2 5/8
Chargeless Pipe Length m 7.5 10
To turn the unit ON or OFF at a preset time.
Maximum Pipe Length m 20 30 20
Pipe Extension 1 2 3
Maximum Elevation Length m 15 20
TIMER CU-PU18TKP
Additional Refrigerant Gas* g/m 10 15 25 ON SET
1 2 33
Power Supply Indoor OFF CANCEL
CAN CEL
Caution For CS-PU9/PU12/PU18/PU24TKP (Important) Please do not use copper pipes that are less than 0.6mm in thickness.
*When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit. Select ON or OFF Timer Set the time.
Example:
OFF at 22:00
OFF
CU-PU24TKP
2
Confirm.
SET
TIMER
26 27
RADIANT COOLING TECHNICAL EXPLANATION RADIANT COOLING TECHNICAL EXPLANATION
()1,)!&'())*$%+
The SKY Series makes the room evenly cool, even though no airflow feeling.
The cooling system of SKY Series gives comfort based on the principle of RADIANT COOLING.
28 28 The temperature in
27 27
26 26 all areas of the room
25 ”It's comfortable!" 25 can be evenly set at
24 24 ”It's comfortable!"
Temperature 23
22
23
22
a comfortable level.
21 "It's cold!" 21
distribution 20 20
19 19
18 18
17 17
˚C ˚C
direct contact with cold air for too long, some people experience Air velocity
distribution Discharge
No Air Feeling Area
*Meter per second
airflow
discomfort and dry skin. No Air Feeling Area
Intake airflow
Test conditions: Measured in stable operation at 25˚C cooling with fan speed set at "HI."
Inspired by the cooling effect of caves,
Doctor Naoshi Kakitsuba investigated the
benefits of RADIANT COOLING. He found that this RADIANT COOLING REMOVES HEAT FROM CEILING AND WALLS
gentler and more even cooling method results in
a greater feeling of comfort and wellbeing. SKY Series makes people comfortable because the radiant heat from ceiling is less.
DR NAOSHI KAKITSUBA
Average Average
ceiling temperature: ceiling temperature:
DEPT. OF ENVIRONMENTAL 35˚C 30˚C
SCIENCE AND TECHNOLOGY, Radiant heat
from roof top
MEIJO UNIVERSITY JAPAN and ceiling
Mean Radiant Temperature Mean Radiant Temperature
(Measured by Globe Thermometer) (Measured by Globe Thermometer)
Average 26.2˚C Average 26.2˚C
room temperature: room temperature:
25˚C 25˚C
The globe temperature is about 0.8˚C higher
(=About 1.1˚C higher in terms of how people feel comfortable)
The globe temperature is a composite temperature used to estimate the
effect of temperature, humidity, and solar radiation on humans.
Slightly
THE PRINCIPLE OFTHE PRINCIPLE
RADIANT OF RADIANT COOLING
COOLING uncomfortable Slightly Comfortable
comfortable
20%
Sensation
100%
evaluation
Room
Heat is absorbed by the breeze on the skin, Temp.
Room
Temp.
resulting in a cool feeling. 25 ºC 25 ºC
Conventional Cooling Slightly comfortable Comfortable /
Neither or
Slightly comfortable
Conventional air conditioner Slightly
any side comfortable
The breeze directly contacts Measured in stable operation at 25˚C cooling with fan speed set at "MEDIUM." The actual average room temperature is the same.
60 min. 60 min.
71% 98%
Skin moisture
after 60 minutes 210μS 150μS 210μS 206μS
The breeze cools the walls and ceiling,
which absorb the body heat.
Measured in stable operation at 25˚C cooling with fan speed set at "HI."
34 35
nanoe-G TECHNICAL EXPLANATION nanoe-G TECHNICAL EXPLANATION
!"#$%&'%()*+,-% $".%.//.0$&1.2.''%3/%()*+,
"Particulate matter," also known as PM is made up of a number of components including AIRBORNE
extremely small particles and liquid droplets. Sized at less than 2.5 micrometers (PM2.5), DATA ON REMOVAL OF AIRBORNE BACTERIA WAS PRESENTED BY HARVARD SCHOOL OF PUBLIC HEALTH
RESEARCHERS AT NANO-SYMPOSIUM AT KYOTO UNIVERSITY, 2012
these particles are said to pose health problems as they can easily enter our lungs.
In a large space of 40 m³
Removal effect has been evaluated.
PARTICLE SIZE COMPARISON The effect after 100 minutes in a 40 m³ test space [about the size of a 10 September 2012 by Harvard University and Kyoto University.
POLLEN BACTERIA / FINE 1 tatami mat room], not the effect in a space where actually used. Test methods: Bacteria removal method: Release of nanoe-G ions.
MOULD PARTICLES Target: Airborne bacteria, Test results: It is estimated that after three hours
Size “Performance evaluation of a novel ionizer for air purification applications”. of operation the nanoe-G will achieve 2.7 log10 reductions, ~ 1 log10 reduction
POLLEN
∙ Exhaust Gas
0.001µm-0.1µm ∙ Haze
∙ Cigarette Smoke
Small AIRBORNE
SOURCES OF PM2.5
TARGET SUBSTANCE EFFECTIVENESS TESTING TEST REPORT METHOD RESULT
PM2.5 can be found suspended in the air, including dust, SUBSTANCE NAME INSTITUTE NO
dirt, smoke and liquid droplets. These fine particles The AC with nanoe-G was
come from man-made sources such as the combustion PM2.5
Cigarette Smoke
(as PM2.5) 99%
FCG Research Test Report
operated in a test room (23m³) and
the concentration of PM2.5 was
99% removal from the
air after 202 minutes of
Institute, Inc No. 25034
of fossil fuels, open burning and industrial processes as measured by PM2.5 Digital Dust
Indicator.
operation.
1.8
Kitasato nanoe-G was operated in a test
1.6 Research KRCES-Env. chamber (200 Litre) and the 99% removal from the
1.4 99% Center for Test Report phages were collected and phage air after 5 minutes of
Environmental 1RB count of the collected air was operation.
1.2 80 min 202 min Science calculated.
1.0
0.8
90% removal 99% removal
nanoe-G was operated in a test
0.6 chamber (200 Litre) and the
influenza viruses were collected 99% removal from the
0.4 air after 5 minutes of
Virus and the virus titers were
0.2 operation.
calculated by the Reed and
0.0 Muench method.
0 30 60 90 120 150 180 210 240 270 300
99% 99%
í Test Report no. : 25034 í.5&(6%LR7HVW5HSRUWQRB air-conditioners in a larger test room (25m³) would be able to
UP TO *1 UP TO *2 Bacteria : Staphylococcus aureus (NBRC 12732)
PM2.5 : Cigarette Smoke (as PM2.5) remove the influenza virus as effectively as the phage.
Effectiveness is measured on 0.3μm-2.5μm. í .5&(6(QY7HVW5HSRUWQRB
PM2.5 BACTERIA Virus : Escherichia coli phage (øX-174 ATCC
(Specific size only)
VIRUSES 13706-B1) Kitasato The AC with nanoe-G was
This removal effect is not proven for all the and MOULD Research KRCES-Bio. operated in a test room (25m³) and 99% removal from the
: Influenza (H1N1) 2009 Virus Penicillium pinophilum
airborne toxic substances. Mould 99% Center for Test Report aerosol was collected and fungal air after 90 minutes of
í .5&(6(QY7HVW5HSRUWQRB (NBRC 6345) 1RB
All results are based on specific testing conditions. Mould : Penicillium pinophilum (NBRC 6345) Environmental spores count was calculated. operation.
All tests are not demonstrated under actual usage Science
All results are based on specific testing conditions.
situation.
All tests are not demonstrated under actual usage situation.
Remark: All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
36 37
nanoe-G TECHNICAL EXPLANATION nanoe-G TECHNICAL EXPLANATION
ADHESIVE
Odour Intensity
Test Subject: Adhesive smell of tobacco smoke 3.25
(detection threshold) 1 Level Down
Test Chamber: 20m³ 2 Able to recognise a smell,
3
0
The air-conditioner first The fan operation will run Natural Ion Wind spreads nanoe-G deactivates bacteria
Initial After 2 hours
has to be turned off. automatically for 30 minutes with the nanoe-G particles that are and viruses that are trapped in
flaps slightly open to ensure the released from the nanoe-G the filter within 2 hours.
internal components are dry and free generator.
from condensation.
ADHESIVE Remark: Remark: Remark:
Main power must be switched The 30-minute fan operation is only applicable Depending on the Air Conditioner’s accumulated operation time, nanoe-G In-Filter
on for the entire duration. when the unit has been operated in COOL /DRY Deactivation may be activated only once a day.
TARGET SUBSTANCE TESTING TEST
EFFECTIVENESS METHOD RESULT mode.
SUBSTANCE NAME INSTITUTE REPORT
NO
Fan Operation : On Fan Operation : Off
Flap : Flaps slightly open Flap : Closed
The AC with nanoe-G was operated 99% inactivation after 24 nanoe-G LED : On nanoe-G LED : On
Staphylococcus Japan Food Test Report in a test space (10m³) and viable hour operation of
Bacteria aureus 99% Research No. cells were counted by pour plate nanoe-G. (compared to the
(NBRC 12732) Laboratories 11047933001-02 method. original condition/
ventilation mode) IN-FILTER DEACTIVATION
99% 99%
UP TO *3 UP TO *4 AVERAGE
90%
í7HVW5HSRUWQXPEHU
Bacteria : Staphylococcus aureus (NBRC 12732) ADHESIVE ODOUR í7HVW5HSRUW1R
UP TO
BACTERIA í7HVW5HSRUWQXPEHU All results are based on specific BACTERIA
and VIRUSES Virus : Bacteriophage (Phi X 174 NBRC 103405) (TOBACCO SMELL) testing conditions. and VIRUSES INFLUENZA
í7HVW5HSRUWQXPEHU All tests are not demonstrated under actual (H1N1)
INHIBITS MOULD GROWTH usage situation. INHIBITS MOULD GROWTH
Mould : Cladosporium cladosporioides (NBRC 6348) 2009 VIRUS
38 39
iAUTO-X TECHNICAL EXPLANATION iAUTO TECHNICAL EXPLANATION
)-+!$"%&'';*4< !"#$%&'()'"!
*+%,#+!%-%!'#&.%-/-0
iAUTO-X cools you down 35% faster compared to
35 %*
Panasonic Standard non-Inverter model with high fan.
Room Temperature SINE WAVE DRIVE 1. FAST COOLING
AT START UP
35ºC Faster Cooling iAUTO utilises high efficient Sine Wave DC motor to
realise both powerful cooling and energy saving. At start up, iAUTO will run at
* Comparison of 1.5HP PREMIUM Inverter super high fan speed to cool
with iAUTO-X mode and Standard
non-Inverter model with cooling mode the room faster, 15% faster
SINE WAVE COMPARISONS
PREMIUM Inverter: iAUTO-X Mode for cooler comfort.
29ºC iAUTO-X Mode, Outside Temperature: 35˚C
/24˚C
75
-#!'(-!*&%)-4%+9$$:
3. AUTOMATIC FAN SPEED
Efficiency (%)
Reduced current distortion enables fan motor to start faster, 70
65
at super high fan speed to help reduce power consumption. Speed (r/min)
3. LOW VIBRATION
LOW SPEED Motor loads run smoother with low vibrations resulting in quieter operation.
warmer cooler
Indoor temperature is measured using 150 sensors to get the average room temperature. Total power consumption amount is measured
for 2 hours under stable operation.
This ensures the accuracy of indoor temperature data. At Panasonic Amenity Room (size: 16.6m²)
The effect differs according to conditions
in installation and usage.
*Applicable to PREMIUM INVERTER only. *Applicable to STANDARD INVERTER, STANDARD Non-INVERTER & DELUXE Non-INVERTER.
40 41
FEATURES COMPARISON FEATURES COMPARISON
FEATURES COMPARISON
Split Type ELITE Inverter PREMIUM Inverter STANDARD Inverter DELUXE Low Watt Low Watt STANDARD Non-Inverter Low Voltage
Wall-Mounted
CS-VU10SKP CS-U10TKP CS-U18TKP CS-PU9TKP CS-PU18TKP CS-XN5SKJ CS-KN5SKJ CS-PN5SKJ CS-PN18SKP CS-YN5SKJ CS-UV5SKP
CS-VU13SKP CS-U13TKP CS-U24TKP CS-PU12TKP CS-PU24TKP CS-XN7SKJ CS-KN7SKJ CS-PN7SKJ CS-PN24SKP CS-YN7SKJ CS-UV9SKP
CS-VU18SKP CS-XN9SKJ CS-KN9SKJ CS-PN9SKJ CS-YN9SKJ
CS-PN12SKJ
Cooling Models
COMFORT
RADIANT COOLING
Radiant Cooling
iCOMFORT
iAUTO-X
SLEEP SLEEP
Inverter Control
iAUTO
Quiet Mode
Powerful Mode
Personal Airflow
Creation
Airflow Direction
Control (Up & Down)
Manual Horizontal
Airflow Direction
Control
Automatic Operation
Mode (Cooling)
CLEANER AIR
nanoe-G
Anti-Dust Coating
Anti-Bacterial Filter
DUST SENSOR
Dust Sensor
Odour-Removing
Function
Removable,
Washable Panel
CONVENIENCE
24-Hour Dual
ON & OFF
Real Setting Timer
24-Hour
ON & OFF Real
Setting Timer
LCD Wireless
Remote Control
Wired Remote
Control (Optional) (Optional) (Optional) (Optional) (Optional)
RELIABILITY
Random Auto Restart
(32 Restart Patterns)
(Random)
Top-Panel
Maintenance Access
Self-Diagnostic
Function
42 43
FEATURES EXPLANATION ACCESSORIES
CZ-RD514C
iAUTO-X POWERFUL MODE
Come home to fast cooling. Then enjoy
continuous comfort with Shower Cooling which MANUAL HORIZONTAL
avoids direct cooling.
AIRFLOW DIRECTION CONTROL CS-VU10SKP, CS-VU13SKP, CS-VU18SKP
SOFT DRY OPERATION MODE CS-U10TKP, CS-U13TKP, CS-U18TKP, CS-U24TKP
Starts with cooling to dehumidify, then provides CS-PU9TKP, CS-PU12TKP, CS-PU18TKP, CS-PU24TKP
SLEEP MODE continuous breeze at a low frequency to keep a
Delays off timer with temperature control SLEEP room dry without much change to the temperature.
for better sleep.
AUTOMATIC OPERATION MODE
CLEANER AIR
The unit must be in cool or dry mode and the fan speed
must be set to automatic.
DUST SENSOR ANTI-BACTERIAL FILTER
Monitors particle concentration levels and DUST SENSOR The Anti-Bacterial Filter combines three effects
turns on nanoe-G if levels are high. in one: anti-allergen, anti-virus and anti-bacteria REMOVABLE, WASHABLE
protection to provide clean air. PANEL
CONVENIENCE
24-HOUR DUAL ON & OFF 24-HOUR ON & OFF LCD WIRELESS REMOTE
REAL SETTING TIMER REAL SETTING TIMER CONTROL
This feature enables you to preset two different The exact operating time (hour and minute) of the air
sets of start/stop operation timer (hour and conditioner can be set in advance. From here on, the
minute) within a 24-hour time frame. unit will operate in accordance to these preset hours
every day until the system is reset.
RELIABILITY
44 45
MODEL LINE-UP MODEL LINE-UP
Wall-Mounted
ELITE
INVERTER
Page 22-23
CS-VU10SKP CS-VU13SKP CS-VU18SKP
(CU-VU10SKP) (CU-VU13SKP) (CU-VU18SKP) (CS-VU10SKP)
Wall-Mounted
PREMIUM
INVERTER
Page 24-25 CS-U10TKP CS-U13TKP CS-U18TKP CS-U24TKP
(CU-U10TKP) (CU-U13TKP) (CU-U18TKP) (CU-U24TKP)
Wall-Mounted
STANDARD
INVERTER
Page 26-27 CS-PU9TKP CS-PU12TKP CS-PU18TKP CS-PU24TKP
(CU-PU9TKP) (CU-PU12TKP) (CU-PU18TKP) (CU-PU24TKP)
XN MODEL
Wall-Mounted
DELUXE
LOW WATT
Page 28
KN MODEL
Wall-Mounted
LOW WATT
Page 29
PN MODEL
Wall-Mounted
STANDARD
NON-INVERTER
Page 30
Wall-Mounted
STANDARD
NON-INVERTER CS-PN18SKP CS-PN24SKP
Page 31 (CU-PN18SKP) (CU-PN24SKP)
YN MODEL
Wall-Mounted
STANDARD
NON-INVERTER
Page 32
UV MODEL
Wall-Mounted
LOW VOLTAGE
Page 33
46 47