O n e pa rt C e m e n t i t i o u s S e l f-s m o ot h i n g I n d u st r i a l
Topping
Description
Dr. Fixit CSL 4000 is composed of special cement, properly selected & graded aggregates, modified with
polymers, plasticiser and set of control additives. It is a one part self-smoothing compound which only requires a
measured amount of clean water to produce a self-smoothing, free flowing material.
It is used as an Industrial grade Cementitious topping and also for leveling of floors before application of any
808 Dr. Fixit CSL 4000
modern flooring system because it provides smooth & leveled surface. Dr Fixit CSL 4000 is applied at thickness
from 3 to 15 mm (Thickness parameters mentioned in Features & Benefits).
Dr. Fixit CSL 4000 is used extensively for upgrading floors to specified levels prior to the installation of high risk
stocking systems.
Specification
Specification meets requirement of BS: 6319, BS: 1881.
Areas of Application
Dr Fixit CSL 4000 is used as self smoothing topping for
}} Finishing rough undulated floors which demands high degree of wear resistance.
}} Seamless floor refurbishment topping.
}} Renovation & up gradation of existing & new concrete floors.
}} Industrial & ware house concrete floors.
}} Pre-fabricated concrete floors.
}} Cementitious underlay for tiles, carpets, vinyl sheets, linoleum, rubber & other flooring materials.
Method of Application
1 S u r face P r epa r at i o n
}} The substrate should be clean, sound and free from loose material and contamination such as plaster, oil, paint,
grease, etc. Wire brush or abrade the surface by mechanical means or light sand blasting.
}}Degrease oil & grease by using degreasing solvents like xylene, toluene, acetone, thinner, etc.
}} New concrete should be at least 7 days old.
266
808-29-12-11
Industrial Floorings
}} Large cracks and holes may be filled using a mix consisting of equal volumes of Dr. Fixit CSL 4000 and clean
sharp sand made up to a trowelable mortar consistency, by the addition of required quantity of water.
2 Priming
}}Prime the substrate with Dr. Fixit Pidicrete MPB in 1:3 dilution with water initially. After this first coat dries, the
area should be be primed with Dr.Fixit Pidicrete MPB in 1:1 dilution with water prior to the application of Dr. Fixit
Note : Start with minimum recommended water powder ratio and then keep adding water until the desired con-
sistency is achieved. In any case do not use more water than the outer limit of recommended water powder ratio.
4 Appl i c at i o n
}}Lay the mix in bays marked to ensure coverage/ required thickness.
}} Pour the mixed material onto the primed substrate, spread with a serrated trowel or squeegee and allow to self-
level.
}} The material must then be rolled with spiked roller to release air and achieve final leveling. Rolling must be done
immediately after placing the material. Do not attempt to float the setting surface.
}} The required thickness must be achieved in one application. Also the best results are achieved when the pouring
and leveling is a continuous process until the designated area is completed. Good site organization is essential.
}} The discharge point of the pump hose should be approximately 200 mm from the floor to prevent splashing &
air entrapment.
}} Do not create new edges & fill the material in the middle.
}} Large areas should be subdivided by using temporary dividing strips.
}} Freshly laid Dr. Fixit CSL 4000 should be protected from direct sunlight and/or strong drying winds until the
material is hard (Minimum 24 hours).
5 C le a n i n g
All tools & tackles are to be cleaned immediately after application with soap water solution.
6 C u r i n g
Curing is generally not required, as it is a self curing system.
267
Dr. Fixit CSL 4000
Industrial Floorings
Where floors with extensive damage or contamination or floor level deviation is more than 15mm, the
}}
}}
Technical Information
Pidilite Industries Limited DISCLAIMER The product information & application details given by the company
Construction Chemicals Division & its agents has been provided in good faith & meant to serve only as a general
Ramkrishna Mandir Road, Post Box No. 17411 guideline during usage. Users are advised to carry out tests & take trials to ensure on
the suitability of products meeting their requirement prior to full scale usage of our
Andheri (E) Mumbai 400059 INDIA
products. Since the correct identification of the problems, quality of other materials
Tel +91-22-2835 7000 • Fax +91-22-2835 7008
used and the on-site workmanship are factors beyond our control, there are no
www.doctor-fixit.com • drfixitadvice@pilmail.com expressed or implied guarantee / warranty as to the results obtained. The company
269
Dr. Fixit Advice Centre (Toll Free No.) 1800-209-5504 does not assume any liability or consequential damage for unsatisfactory results,
arising from the use of our products.