Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Key Plan:

SHEET-1 SHEET-2 SHEET-3 SHEET-4


6 8 9 10 -

I
I

13000 12475 12500 8500 14000


- I I I
. II

E
ll I
. •
DVE CERTIFIED
Ref.: M006-MML-ELE-DRS-01101 Rev 0.10
I I Date:29-MAY-2018
I I

• ..... • ('i) I I
0 0
I ('i)
.....
NI I ('i)
.....
NI
SAFETY, HEALTH AND
ENVIRONMENTAL INFORMATION
• 6,
(9 (9 In addition to the hazards/risks normally associated with the
VRVUNITS
55 1 <( types of work detailed on this drawing, note the following :

~ (9 0
·so 1-b
1
(ol)42)
6·s b <(
0
I
CONSTRUCTION

lws
wen lo I-
·en r I
ws
·w r
WU)

MAINTENANCE/CLEANING
z C9 1zOsC9
I

l.I-Os0
<( I
.I- 0
<( I
::> w
I=> w
DECOMMISSIONING/DEMOLITION

SAw12 I ~
z.1- co

wZ~ I- co
:JIB
IO
o (9 :JIB
IO
o (9 It is assumed that all works will be carried out by a competent
0
.o::: cb cb contractor working , where appropriate, to an approved method
I- 0 statement
0 I- .o::: 0
<( 0 0 <( 0 0
Notes:

~ILL~ ~ILL~
1
21302 SCALE 1:100

6
\ FOR CONSTRUCT ION I
13000 12475

2Nos.GI CONDUITS DROP


Reference Documents:
I FVEL ELE ROOM(-1 027)
M006-GDB-ARC-MD3-YWST070-ZZ-13580_Rev-7 .11
E GG/B8/L16/006
M006-G DB-ARC-M D3-YWSTO?O-ZZ-80560 _ Rev-7
M006-GDB-STR-MD3-YWST070-ZZ-43231_Rev-70.5
M006-GDB-ELE-DWG-YWST070-AG-43643 Rev-3
-----€)
I /B7/L 16/004
'
I'
GGIBB/L 16/001
i' Scale: o
I I I I
1
!I I I
2
I I j I
3
I I I I
4
I I I I
5 [m}
j
'
I Scale: 1:100
: Drawing Revision History
GG/B8/L 16/005 Rev Description App. Date
1 SHOP DRAWING· ISSUED FOR APPROVAL HBG 08/06!2017
2 SHOP DRAW ING - ISSUED FOR APPROVAL PVN. 29/1);1 '20,ta.
G/B7/L 16/001
' Purpose of Issue:
PCU-AG-02 I ISSUED FOR APPROVAL
I
' Design Validation:
LIGHTING GENERAL NOTES
VRV UNITS 1 j 2 1. ALL DIMENSIONS ARE IN MILLIMETERS AND UNLESS OTHERWISE
SONO Reference:
DVE Reference:
Date.
Date:
( 0.042 ) '
GG/B8/L 16/004 GG/88/L 16/ 002
INDICATED. Client:
ALL MATERIALS SHALL BE AS PER APPROVED MATERIAL SUBMITTAL
FOR STANDARD NOTES AND LEGENDS, REFER TO DWGS,
Qatar Railways Company
0 6- DB-ELE-DWG-YCA N N-Z - 4 01 Rev-1 240 2 R v-2
FOR ELECTRICAL SYSTEM STANDARD INSTALLATION DETAILS .REFER TO P.O. Box 29988 ~ \
PCU-AG-01 RAIL J--.;! jJI
DRAWING M006-GDB-ELE-DWG-YCSTNNN- ZZ-24001,24002,2401 O_Rev-4 & Doha - Qatar
24008,240 11 TO 24014_Rev-3, 24003 TO 24007,24009_Rev-5 CL.....,191 •~ .! II 1 ·,
Accampti~ 1 ing Vislan
FOR LIGHTING LUX LEVEL CALCULATIONS REFER TO DIALUX LIGHTING
CALCULATION REPORT M006-GDB-ELE-CLN-00031_Rev-2 Originator: Contractor:

SA
G/87/L 16/003

L__________________ ______________ _J
: GG/88/l16/003
G/B7/ L 16/002

:
REFER TO BASIC OF DESIGN M006-GDB-ELE-RPT-00001_Rev-05 FOR
LUMINAIRE SCHEDULE.
7. FOR TRUNKING INSTALLATION REFER LV CONTAINMENT DRAWING
M006-GDB-ELE-DWG-YWST070-AG-21201 TO 21024_Rev-3.
ALYSJ
joint vent"r e

PO Box 24375 Doha , State of Qatar


,1,~!,~~
PO Box 24375
lfil ~
Doha, State of Qatar
8. PULL BOXES FIXAT MAXIMUM 10M SPACING AND TO LIMIT THE NUMBER Tel -t97444109400 Fax +974 44 109500 Tel ..-974 44 109400 Fax -t-974 44109500
OF BENDS IN CONDUIT TO NOT MORE THAN TWO 90° BENDS. Project:
POSITION OF THE CONDUIT AND BOXES SHOWN ARE INDICATIVE ONLY.
EXACT ROUTING OF THE CONDUIT AND POSITION OF BOX SHALL BE AS Qatar Integrated Railway Project
NEAR AS POSSIBLE TO THE LIGHT FIXTURE AS PER SITE CONDITIONS. Doha Metro: Gold Line Underground
10. EMERGENCY LIGHTING CIRCUIT MAY BE INSTALLED WITH CONDUITS
M006
2 AT GRADE ROOF LEVEL LIGHTING LAYOUT SHEET 2
ACCORDING TO DETAIL : M006-GDB-ELE-DWG-YCSTNNN-ZZ-24004_REV-5
1. ALL LIGHTING CABLE SIZE SHALL BE AS PER DB SCHEDULE.
12. DIMENSIONS MAY VARY AS PER CONSTRUCTION CONDITIONS AND
Discipline:
ELECTRICAL
21302 SCALE 1:100 CONSTRUCTION TOLERANCES. Drawing Title:
13.LIGHTING LAYOUT IS UPDATED AS PER GSAS REQUIREMENT CENTRAL
BATTERY SYSTEM & LIGHTING CONTROL GROUPING . AL AZIZIYAH STATION
LIGHT FIXTURE NUMBERING PHILOSOPHY 14. FOR AREA LIGHTING FIXTURES ARE CONTROLLED THROUGH LIGHTING AT GRADE LEVEL
CONTROL SYSTEM INTERFACED WITH BACS. LIGHTING LAYOUT SHEET 2
A-R1 - L1 - 01 5 .FOR LIGHTING LOAD SCHEDULE SHOP DRAWINGS REFER TO DRAWING
M006-GDB-ELE-DWG-YWST070-UL-21320_Rev-3 , Originator: Contractor·

TT M006-GDB-ELE-DWG-YWST070-PL-21320 &21321_Rev-3 , Draw n RPS 29/04/2018

~
LIGHT FIXTURE SEQUENCE NUMBER Checked
DISTRIBUTION BOARD ABBREVIATION SCHEDULE M006-GDB-ELE-DWG-YWST070-SW-21320 &21321 Rev-3, Checked KD 29/04/2018
LIGHT FIXTURE TYPE M006-GDB-ELE-DWG-YWST070-CL-21320 &21321_Rev-3, Approved PVN 29/04/2018 Approved

DB ABBREVIATION NORMAL DB NAME EMERGENCY DB NAME M006-GDB-ELE-DWG-YWST070-AG-21320 _Rev-2.


DB ABBREVIATION -----CIRCUIT NUMBER Scale: 1:100 Sheet Size:
16.EMERGENCY VITAL LIGHTING SYSTEM SHALL BE DESIGNED AS PER
Drawing No: Rev:
G AZI-GL-NS-DBL-CL-001 GG AZI-GL-LS-DBL-CL-001 ~ - - - - - D I S T RIBUTION BOARD REFERENCE NFPA 101 STANDARD.
M006-GDB-ELE-DWG-YWST070-AG-21302 2
THE DRAVVING AND ANY INFORMATION OR DESCRIPTIVE MATTER SET OUT HEREON IS LICENSED TO THE QATAR RA ILWAYS COMPANY AND JS CONFIDENTIAL AND SUBJECT TO COPYRIGHT. IT M UST NOT BE DISCLOSED, LOANED COPIED OR USED FOR MAN UFA CTURING, TEN DERING OR FOR ANY OTHER PURPOSE WITHOUT WRITTEN PERMISSIO N. ©QATAR RAILWAYS C OMPANY.
100mm on Oriaina!