Autoranging Digital Clampmeters - 1200A DC / 1000A AC TRMS

1080-TRMS 3600

TRMS, Auto / Manual, 35/6 Digit, 1200A DC & 1000A AC (TRMS) DC Current 400A, 1200A
6,000 Count LCD with Backlight, APO, 3¾ Digit, 4,000 Counts, 40 Segment Accuracy ±(1.5%rdg+5dgts)
Capacitance, Frequency, Duty Cycle & Bargraph, Auto & Manual Ranging, (upto 700A)
Temperature Ranges PEAK HOLD, MAX / MIN, D ZERO, ±(2%rdg + 5dgts)
DATA HOLD functions, APO (700~1200A)
Ranges Ranges TRMS Overload 1200 A DC max. for 1 min.
DC Voltage 600mV / 6 / 60 / 600 / 1000V AC Current 400A, 1000A DC Volt 400mV, 4V, 40V, 400V, 600V
Accuracy TRMS ±(0.5%rdg + 3dgt) Accuracy ±(2.5% rdg + 5dgt) (50~60Hz) (Auto & Manual Ranging)
AC Voltage 600mV / 6 / 60 / 600 / 750V ±(3.5%rdg + 5dgt)
Accuracy ±(1.0% rdg + 5dgt) Accuracy ±(0.25% rdg + 4dgts)
(40~500Hz)
AC Response 40Hz~1000Hz Resistance 400V, 4kV, 40kV, 400kV,
Overload 1000A AC max. for 1 min.
DC Current 600 / 6000mA / 60 / 600 / TRMS 4MV, 40MV
AC Voltages 4V, 40V, 400V, 600V
1200A (Auto & Manual Ranging)
(Auto & Manual Ranging)
Accuracy ±(1.2% rdg + 10dgt) Accuracy ±(0.3%rdg + 5dgt) on 400V
Accuracy ±(0.75%rdg + 4dgt)
on 600 / 6000mA (50~60Hz)
±(0.3%rdg + 4dgt)
±(2.0% rdg + 30dgt) on 4kV~400kV
±(2%rdg + 4dgt) (40~500Hz)
on 60 / 600 / 1200A ±(0.5%rdg + 4dgt) on 4MV
Note : 400mV AC for Referance
Overload 1200A DC Max. for 1min. ±(2.0%rdg + 4dgt) on 40MV
only
TRMS
for A Capacitance 4nF, 40nF, 400nF, 4mF, 40mF
AC Current 600 / 6000µA / 60 / 600 / (Auto & Manual Ranging)
1200A on - 20°C~400°C
Accuracy ±(3%rdg + 20dgt)
Accuracy ±(2.0% rdg + 30dgt) ±(1.5% rdg + 15dgt)
on 4nF (Use D ZERO)
on all Ranges on 400°C~1000°C
±(3%rdg + 4dgt)
AC Response 40 Hz~1000Hz ±(0.75% rdg + 5 dgt)
on 40nF to 20mF
Overload 1200A AC Max. for 1min. on 0°F~750°F
±(6%rdg + 4dgts) above 20mF
for A ±(1.5% rdg + 15 dgt)
on 750°F~1832°F Frequency 4kHz, 40kHz
Resistance 600V / 6 / 60 / 600kV / 6 / (Auto & Manual Ranging)
60MV µA
(For Non Distorted Waveforms
Accuracy ±(0.8% rdg + 5dgt) Measurement
Only)
on 600V for HVAC 600.0µA / 6000µA
Flame Accuracy ±(0.1%rdg + 2dgts)
±(0.8% rdg + 3dgt)
on 6 / 60 / 600kV / 6MV Sensors Sp. Function Audible Continuity,
±(1.0% rdg + 25dgt) Accuracy ±(1% rdg + 20 dgt) Diode Test function
on 60MV Sp. Function Diode Test, Audible Power One 9V Battery
Capacitance 9.999 / 99.99 / 999.9nF / Continuity, Data Hold Battery Life 150 hours (typical)
9.999 / 99.99 / 999.9µF / Power One 9V Battery Low Battery ‘ ‘ is indicated.
9.999mF Low Battery ‘ + ’ is indicated Protection 600VDC or AC rms overload
Accuracy ±(3.5% rdg + 60dgt) Battery Life 200 hours typical protection in DCV, ACV,
on all ranges except Dimensions 238 x 90 x 48mm (approx.) Diode, Ohms, Hz, Continuity.
±(5.0% rdg + 10dgt) Weight 320gms Including Battery
Dimensions 250 x 100 x 46 mm (approx.)
on 999.9µF & 9.999mF (approx.)
Weight 386 gms Including Battery
Frequency 99.99Hz~10.00MHz Jaw Opening 30mm
(approx.)
Accuracy ±(0.01% rdg + 3dgt) Measuring CAT IV 600V
Duty Cycle 0.1%~99.9% Catagory Jaw Cable Dia 55mm max.
Accuracy ±(0.01% rdg + 3dgt) Accessories Supplied with Pair of Test Opening
Temperature -20°C~1000°C / Leads, Battery, K Type Accessories Supplied with a Pair of Test
0°F~1832°F Thermocouple (upto 260°C), Leads, Carrying Case, Battery
Accuracy ±(1% rdg + 5dgt) Inst. Manual & Carrying Case (installed) & Inst. Manual