** ON A/C 001-001, 003-004, 006-007

Subtask 24-00-00-810-075-C
C.Air Conditioning
(1)Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

21 CAB PR SYS 1(2) FAULT CABIN For CPC 1:


PRESSURE - On panel 49VU, open the
CONTROLLER circuit breaker 1HL.
(CPC) 1(2) FOR CPC 2:
- On panel 122VU, open the
circuit breaker 2HL.
After five seconds, close the
circuit breaker.

21 COND ZONE REGUL ZONE On panel 122VU:


FAULT TEMPERATURE - Open the circuit breaker
1HK.
CONTROLLER
- Open the circuit breaker
2HK.
After five seconds, close the
circuit breaker.

21 AIR FWD (AFT) CRG CARGO On panel 49VU:


VENT VENTILATION - Open the circuit breaker
FAULT 31HN.
CONTROLLER
After five seconds, close the
circuit breaker.

21 VENT AVNCS SYS FAULT AVIONICS EQUIPMENT VENTILATION On panel 122VU:


COMPUTER
- Open the circuit breaker
3HQ.
After five seconds, close the
circuit breaker.

21 AIR PACK 1(2) REGUL PACK For the PC 1:


FAULT
CONTROLLER - On panel 122VU, open
(PC) 1(2) then close the circuit breaker
2HH.
For the PC 2:
- On panel 122VU, open
then close the circuit breaker
22HH.

21 COND AFT CRG HEAT AFT CARGO On panel 49VU:


FAULT
HEAT - Open the circuit breaker
31HN.
CONTROLLER
- After five seconds, close the
circuit breaker.

** ON A/C 011-099, 101-199, 201-300


Subtask 24-00-00-810-075-E
C.Air Conditioning
(1)Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

21 CAB PR SYS 1(2) FAULT CABIN For CPC 1:


PRESSURE - On panel 49VU, open the
CONTROLLER circuit breaker 1HL.
(CPC) 1(2) FOR CPC 2:
- On panel 122VU, open the
circuit breaker 2HL.
After five seconds, close the
circuit breaker.

21 AIR FWD (AFT) CRG VENT CARGO On panel 49VU:


FAULT VENTILATION - Open the circuit breaker
31HN
CONTROLLER
After five seconds, close the
circuit breaker.

21 VENT AVNCS SYS FAULT AVIONICS EQUIPMENT VENTILATION On panel 122VU:


COMPUTER
- Open the circuit breaker
3HQ.
After five seconds, close the
circuit breaker.

21 AIR PACK 1(2) REGUL AIR COND For the ACSC 1:


FAULT
SYSTEM - On panel 122VU, open
CONTROLLER the circuit breaker 49HH,
(ACSC) 1(2) circuit breaker 50HH
and circuit breaker 51HH.
- On panel 49VU, open
the circuit breaker 52HH.
Then close the circuit
breakers.
For the ACSC2:
- On panel 122VU, open
the circuit breaker 53HH,
circuit breaker 54HH,
circuit breaker 55HH and
circuit breaker 56HH.
Then close the circuit
breakers.

21 COND AFT CRG HEAT AFT CARGO On panel 49VU:


FAULT
HEAT - Open the circuit breaker
CONTROLLER 31HN.
- After five seconds, close
the circuit breaker.

** ON A/C ALL
Subtask 24-00-00-810-076-A
D.Auto Flight
(1)Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

FAULT Yellow and Green hydraulic


systems pressurized:
- for the FAC 1: on the
panel 49VU, C/B 5CC1
- for the FAC 2: on the
panel 121VU, C/B 5CC2
Then close the C/Bs after 10
seconds.

22 WINDSHEAR DET FAULT or FAC 1+2 Open then close the C/Bs in
REAC W/S DET FAULT this the order:
- on the panel 49VU, C/B
5CC1 and C/B 14CC1
- on the panel 121VU, C/B
5CC2 and C/B 14CC2.

22 AUTO FLT FCU 1(2) FAULT FCU For the FCU1:


- on the panel 49VU, open
the C/B 9CA1.
For the FCU2:
- on the panel 121VU, open
the C/B 9CA2.
Close the C/B after 5
seconds.
If the fault does not
continue, do a check of the
target and barometer
references shown, and
correct them if necessary
(reset successful).
If the fault continues, open
again the two C/Bs 9CA1
on 49VU and 9CA2 on 121VU.
Close the C/Bs after 7 min,
with an interval less than
5 sec between side 1 and
side 2.
At least 30 sec are necessary
until the end of the FCU1
and FCU2 safety test.
If the fault does not
continue, do a check of the
target and barometer
references shown, and
correct them if necessary
(reset successful)
If the fault continues, end
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

22 One MCDU locked or blank MCDU Open then close the C/B of
Both MCDUs locked or blank FMGC the defective MCDU after 10
seconds:
- For the MCDU1: on the
panel 121VU or panel 49VU,
C/B 11CA1.
- For the MCDU2: on the
panel 121VU, C/B 11CA2.
- For the MCDU3: on the
panel 121VU, C/B 11CA3.

22 FMGC malfunction FMGC On the panel 121VU or 49VU:


- open the FMGC 1 C/B 10CA1
and close it after 10
seconds.
If there is no reset of the
FMGC 1, do a reset of the
FMGC 2 on the panel 121VU:
- open the C/B 10CA2 and
close it after 10 seconds.

** ON A/C 001-001, 003-007


Subtask 24-00-00-810-077-A
E.Communications
(1)Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

23 COM CIDS 1+2 FAULT CIDS - Open the C/Bs in this


order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
- After 10 seconds, close
the C/Bs in this order:
151RH, 150RH.

23 Uncommanded EVAC horn CIDS Press the EVAC/HORN SHUT


actuation OFF switch.
If unsuccessful:
- Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
- After 10 seconds, close
the C/Bs in this order:
151RH, 150RH.
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

other.
On the RMP control panel:
- set the ON/OFF switch to
OFF
- after 5 seconds, set the
ON/OFF switch to ON.

23 Frozen FAP Tape On the panel 121VU, open


reproducer the FAP C/B 170RH.
- After 10 seconds, close
the C/B 170RH.
If unsuccessful:
on the panel 2000VU
- open the tape reproducer
/PRAM C/B 2RX.
After 10 seconds, close the
C/B.

** ON A/C 011-099, 101-199


Subtask 24-00-00-810-077-D
E.Communications
(1)Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

23 COM CIDS 1+2 FAULT CIDS - Open the C/Bs in this


order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
on the panel 49VU, C/B 157RH
on the panel 121VU, C/B
156RH
- After 10 seconds, close
the C/Bs in this order:
156RH, 157RH, 151RH and
150RH.

23 Uncommanded EVAC horn CIDS Press the EVAC/HORN SHUT


actuation OFF switch.
If unsuccessful:
- Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

156RH
- After 10 seconds, close
the C/Bs in this order:
156RH, 157RH, 151RH and
150RH.

23 Frozen RMP RMP You must do a reset of all


the RMPs, one after the
other.
On the RMP control panel:
- set the ON/OFF switch to
OFF
- after 5 seconds, set the
ON/OFF switch to ON.

23 Frozen FAP FAP Open the C/Bs in this order:


On the panel 49VU, CB 171RH
On the panel 121VU, CB
170RH
- After 10 seconds, close
the C/Bs in this order:
170RH, 171RH
If unsuccessful:
on the panel 2000VU
- open the tape reproducer
/PRAM C/B 2RX.
After 10 seconds, close the
C/B.

** ON A/C ALL
Subtask 24-00-00-810-088-A
F.Electrical Power
(1)Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

24 GPU cannot be connected GAPCU If at least one power source


to the aircraft (IDG 1 or IDG 2, APU GEN or
batteries) is connected to
the electrical network of
the aircraft:
- On the ELEC control panel
35VU:
. Push and release the
EXT PWR pushbutton
switch.
If no power source is
connected to the electrical
network of the aircraft:
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

. Push the BAT 1 and BAT 2


pushbutton switches
(the OFF legend goes
off).

** ON A/C 001-001, 003-007


Subtask 24-00-00-810-078-A
G.Fire Protection
(1)Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

26 SMOKE LAV + CRG DET FAULT SDCU On the panel 49VU:


- open the C/B 11WQ
On the panel 122VU:
- open the C/B 12WQ
After 10 seconds, close the
two C/B's.

26 ENG1(2) LOOP k FAULT ENGINE FDU On the panel 49VU:


- For ENG1 FDU, open the
C/B 7WD1.
- For ENG2 FDU, open the
C/B 8WD2.
On the panel 121VU:
- For ENG1 FDU, open the
C/B 8WD1.
- For ENG2 FDU, open the
C/B 7WD2.
- After 5 seconds, close
the C/Bs.

26 APU FIRE LOOP k FAULT APU FDU On the panel 121VU:


- Open the C/Bs 2WG and 1WG.
- After 5 seconds, close the
C/Bs.

** ON A/C ALL
Subtask 24-00-00-810-079-A
H.Flight Controls
(1)Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

27 F/CTL ELAC 1(2) FAULT ELAC Reset the defective ELAC:


F/CTL ALTN LAW FAULT - Make sure that the
hydraulic systems are
depressurized before the
reset.
- Set the ELAC pushbutton
switch to OFF, then to ON.
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

- Make sure that the


hydraulic systems are
depressurized before the
reset.
Open, then close the C/B of
the defective ELAC or SEC.
For the ELAC 1(2):
- On the panel 49VU, C/B
15CE1.
- On the panel 121VU, C/B
15CE2.
For the SEC 1(2)(3):
- On the panel 49VU, C/B
21CE1.
- On the panel 121VU, C/B
21CE2 or 21CE3.

27 E/W FCDC1(2) FAULT FCDC On the panel 49VU:


- For FCDC1, open the C/B
20CE1.
- For FCDC2, open the C/B
20CE2.
- After 5 seconds, close
the C/Bs.

Subtask 24-00-00-810-089-A
J.Fuel
(1)Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

28 Loss of fuel quantity FQIC On the overhead circuit


indication or, breaker panel 49VU:
Simultaneous triggering - Open the C/B 1QT.
of FUEL L XFR VALVE On the rear circuit
CLOSED and FUEL R XFR breaker panel 121VU:
VALVE CLOSED, although - Open the C/B 2QT.
FUEL SD indicates no After 5 seconds, close the
anomaly. two C/B's.

Subtask 24-00-00-810-080-A
K.Ice and Rain Protection
(1)Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

30 ANTI ICE WHC Open then close the C/B of


L(R)/WINSHIELD (WINDOW) the defective WHC.
For the WHC1:
- on the panel 122VU, C/B
5DG1.
For the WHC2:
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

5DG2.

Subtask 24-00-00-810-081-A
L.Indicating/Recording Systems
(1)Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

31 FWS FWC 1(2) FAULT FWC Open then close the C/B of
the defective FWC
For the FWC1:
- on the panel 49VU, C/B 3WW
For the FWC2:
- on the panel 121VU, C/B
2WW.

31 EIS DMC 1(2)(3) FAULT DMC Open then close the


circuit breaker of
the defective DMC
For the DMC1:
- on the overhead C/B panel
49VU, the circuit breaker
10WT1.
For the DMC2:
- on the rear C/B panel
121VU, the circuit breaker
10WT2.
For the DMC3:
- on the rear C/B panel
121VU, the circuit breaker
10WT3.

31 CAPT PFD DU malfunction CAPT PFD DU On the CAPT lightning/loud


speaker control-panel 301VU,
turn the PFD potentiometer
from the BRT position to
the OFF position.
- Wait for more than five
seconds.
On the CAPT lightning/loud
speaker control-panel 301VU,
turn the PFD potentiometer
from the OFF position to
the BRT position.

31 CAPT ND DU malfunction CAPT ND DU On the CAPT lightning/loud


speaker control-panel 301VU,
turn the ND potentiometer
from the BRT position to
the OFF position.
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

On the CAPT lightning/loud


speaker control-panel 301VU,
turn the ND potentiometer
from the OFF position to
the BRT position.

31 F/O PFD DU malfunction F/O PFD DU On the F/O lightning/loud


speaker control-panel 500VU,
turn the PFD potentiometer
from the BRT position to
the OFF position.
- Wait for more than five
seconds.
On the F/O lightning/loud
speaker control-panel 500VU,
turn the PFD potentiometer
from the OFF position to
the BRT position.

31 F/O ND DU malfunction F/O ND DU On the F/O lightning/loud


speaker control-panel 500VU,
turn the ND potentiometer
from the BRT position to
the OFF position.
- Wait for more than five
seconds.
On the F/O lightning/loud
speaker control-panel 500VU,
turn the ND potentiometer
from the OFF position to
the BRT position.

31 EWD malfunction EWD On the ECAM control panel


turn the UPPER DISPLAY
potentiometer from the
BRT + position to the OFF
position.
- Wait for more than five
seconds.
On the ECAM control panel
turn the UPPER DISPLAY
potentiometer from the
OFF position to the BRT +
position.

31 SD malfunction SD On the ECAM control panel


turn the LOWER DISPLAY
potentiometer from the
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

- Wait for more than five


seconds.
On the ECAM control panel
turn the LOWER DISPLAY
potentiometer from the
OFF position to the BRT
position.

Subtask 24-00-00-810-082-A
M.Landing Gear
(1)Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

32 Braking malfunction BSCU On the panel 121VU:


- open the C/Bs 1GG, 2GG,
3GG and 4GG
- after 5 seconds, close
the CB's

32 L/G LGCIU 1(2) FAULT LGCIU 1(2) For the LGCIU 1:


- on the panel 121VU, open
the C/B 52GA then on 49VU,
C/B 1GA. Then close the
C/B 1GA and C/B 52GA
For the LGCIU 2:
- on the panel 121VU, open
then close the C/B 2GA.

Subtask 24-00-00-810-083-A
N.Navigation
(1)Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

34 NAV MMR 1(2) FAULT MMR1(2) For the MMR 1:


- On the panel 49VU, open
the C/B 42RT1.
- After 5 seconds, close the
C/B.
For the MMR 2:
- On the panel 121VU, open
the C/B 42RT2.
- After 5 seconds, close the
C/B.

34 NAV TCAS FAULT TCAS On the panel 121VU:


- Open the C/B 4SG.
- After 5 seconds, close
the C/B.

34 NAV GPWS FAULT GPWC On the panel 121VU:


NAV GPWS TERR DET FAULT Open the C/B 3WZ.
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

the C/B.

34 NAV GPS 1(2) FAULT GPSSU On the panel 121VU:


- For GPSSU1, open the C/B
2SN1.
- For GPSSU2, open the C/B
2SN2.
- After 5 seconds, close
the C/Bs.

34 NAV RA 1(2) FAULT XCVR-RA On the panel 121VU:


- For XCVR-RA 1, open the
C/B 1SA1.
- For XCVR-RA 2, open the
C/B 1SA2.
- After 5 seconds, close
the C/Bs.

** ON A/C 001-001, 003-007


Subtask 24-00-00-810-084-A
P.Water/Waste
(1)Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

38 Fault messages on the Vacuum On the panel 2001VU:


FAP in the cabin System - open the C/B 35MG
Controller - after 30 seconds, close
the C/B.

** ON A/C 005-007, 011-099, 101-199, 201-300


Subtask 24-00-00-810-085-A
Q.Information Systems
(1)Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

46 ATSU malfunction ATSU On the rear circuit


breaker panel 121VU:
- Open the C/Bs in this
order: 3TX1 and 5TX1.
- After 5 seconds, close
the C/Bs in this order:
5TX1 and 3TX1.

** ON A/C ALL
Subtask 24-00-00-810-086-A
R.Engine
(1)Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

70 ENG IGN A+B FAULT FADEC and On the panels 49VU and 121VU
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

70 ENG 1(2) FADEC A(B) FAULT FADEC - For the FADEC 1, C/Bs
2KS1 and 4KS1.
- For the FADEC 2, C/Bs
2KS2 and 4KS2.

Subtask 24-00-00-810-090-A
S.Engine Indicating
(1)Computer Reset Table
ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE

77 Loss of N1VIB and N2VIB EVMU On the panel 121VU:


indications for ENG1(2) - Open the C/B 2EV.
in ECAM SD - After 5 seconds, close the
C/B.