Column Design: Position of Column We Will Design Was Sawn On The Picture Below

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 7

Column design

Position of column we will design was sawn on the picture below

First of all we need to calculate the total load of the structure of a specific arbitrary load we have
defined.

f'c  30MPa fs  390MPa

d_s  20mm f's  390MPa

n  24 B  6m
t  150mm
a  0.5m
Le  4m
b  0.5m
kN
cover  50mm 22
3
m
kN
Load On Slab slab  150mm 25
3
m

kN
ceiling  0.4
2
m

kN
mechanical  0.2
2
m
kN
partition  1
2
m
kN kN
DL  cover  slab  ceiling  mechanical  partition  6.45 LL  3
2 2
m m

2
AT  B Le  24 m
Tributary area
KLL  4
2
AI  KLL AT  96 m

4.572
LL  0.25   0.717
AI
2
m

3
LLo  LL LL  2.15  10 Pa
Loads of wall
4 3
Void  30mm 30mm 190mm 4  6.84  10  m
Brick_halo10   120mm  Void 
55  kN 3
 20  1.648  10 Pa
 2 3
 1m  m

Load on column
5
Pd_slab  DL B Le  1.548  10 N

4
Pl_slab  LL B Le  7.2  10 N

kN 4
Pb1  25cm ( 70cm  150mm) 25 Le  1.375  10 N
3
m

kN 4
Pb2  25cm ( 70cm  150mm) 25 Le  1.375  10 N
3
Cross Sectional Area m

Pwall1  Brick_halo10 ( 4m  70cm)  Le  21.748 kN

4
Pwall2  Brick_halo10 ( 4m  70cm)  B  3.262  10 N

Number of floors number  12

3
P_D  ( Pd_slab  Pb1  Pb2  Pwall1)  number  2.449  10  kN

5   0.75
P_L  Pl_slab number  8.64  10 N
g  0.03
6
Pu  1.2 P_L  1.6 P_D  4.955  10 N

Calculate The Cross Sectional Area


Pu
Ag 
0.8(0.85f  g (f y  0.85f c' ))
'
c

Pu : the total axially ultimate 0load


f 'c : Concrete compression strength
f y :Rebar strength
Pu 2
Ag   0.227 m

0.8  0.85 f'c  g f's  0.85 f'c
 

we take b  0.5m h  0.5

Ag_Design  b  h  0.25m Accepted

Radius of Gyration
Ic
r
A
r : Radius of giration
1
Ic = bh3 :moment Inertia
12
A  bh :cross sectinal area

1 3 3
Ic   b  h  5.208  10 m
12
Ic
r   0.144
Ag_Design

k  1 Lu  4m

k  Lu
 27.713 m
r

12M1
34   44.364
M2

This Column Is swaying column


Rebar Calculation
 Mux M  2d
 ey  ,ex  uy    (compression _ control)
 Pu Pu  3

  ey
P bhf 'c   0.5
As   u   d  d'
  3hey  1.18  fy
 2 
 d 

  ex
 Pu bhf 'c  d  d'  0.5
As    
  3hex  1.18  fy
 d2 

min  b  h
A s  A 's 
2

A st

Ag

Mux  30kN m d  500mm  20mm  0.48m


Muy  35kN m d'  20mm

Mux 3 Muy 3
ey   6.055  10 m ex   7.064  10 m
Pu Pu

ey
 0.5
 Pu b  h  f'c  d  d' 3 2
As      8.238  10 m
 3
h  ey
 1.18mm
 1 f's
 2 
 d 

ex
 0.5
 Pu b  h  f'c  d  d' 3 2
As'      8.721  10 m
 3
h  ex
 1.18mm
 1 f's
 2 
 d 

As'
 0.038 min  0.038
Ag
2
( 30mm) 3 2
( 11 2  9 2)   9  10 m
4
11 2  9 2  40 40DB30
Stirrup Calculation
Vu  max(abs(Vux ),abs(Vuy ))
Nu
Vc  0.17(1  ) f 'c bd
14A g
Vu  Vc
Vs 

Vc1  0.33 f 'c bd

d 2stirrup _ steel _ diameter


Av 
4
A V  f yt
S3  ,
0.35  b
d
S2  min( ,600mm)
2
Smax  min(S2 ,S3 )

6
Nu  Pu  4.955  10 N
Stirrup Calculation
6
Vu  0.8Pu  3.964  10 N
2
Nu  m
Vc  0.17  265.455 kN
14 Ag

Vu    Vc 6
Vs   5.019  10 N

2
  ( 10mm) 5 2
Av   7.854  10 m
4

Av f's kN
S1   175.032
0.35 b m
Load moment interaction diagram
a) Point A—Pure Axial Load.
b) Point B—Zero Tension, Onset of Cracking.
c) Region A–C—Compression-Controlled Failures.
d) Point C—Balanced Failure, Compression-Controlled Limit Strain.
e) 5. Point D—Tensile-Controlled Limit.
f) Region C–D—Transition Region.
g) 7. Strain Limit for Beams
Interaction diagram is a graph of parametric function, where

Abscissa: Mn(a)

Ordinate: Pn(a)

Pn ( a) min[   ( a) ( 0.85fc  a b  As  Fs ( a)  As  fs ( a) ) Pn_maz ]

 ( a)  As  b    0.85fc  a b  a  h   As  b  a  
h
Mn ( a)  2 2  2  d 
 2  d    

P(kN) Moment Interaction diagram


5

2
Moment Interaction
1
diagram
0 M(0.1kN.m)
0 2 4 6 8
-1

-2

-3

You might also like