RC14-1352 Concrete Building Structures

Seismic Analysis, Design and Detailing


of
Reinforced Concrete Buildings Elements
according to
SNI 2847/ACI 318M

RC14-1352: Concrete Building Structures

Prof. Tavio, Ph.D 1

Table 5 - Splice Requirements

Prof. Tavio, Ph.D. 1


RC14-1352 Concrete Building Structures

100 mm

Figure 3 - Lap Splice Requirements

Table 6 - Transverse Reinforcement Requirements

Prof. Tavio, Ph.D. 2


RC14-1352 Concrete Building Structures

Prof. Tavio, Ph.D. 3


RC14-1352 Concrete Building Structures

Prof. Tavio, Ph.D. 4


RC14-1352 Concrete Building Structures

Prof. Tavio, Ph.D. 5


RC14-1352 Concrete Building Structures

Acv = shear area


1.For Rectangular Sections
ACV = b w .d
where
here
Av f c' .bw b w
( )min = max( ; )
s 4fys 3fys
2. ForCircularSections
1
ACV = Ag = πD2
4
where
Av f c' .D 0.8.D
( )min = max( ; )
s 4fys 3fys

Prof. Tavio, Ph.D. 6


RC14-1352 Concrete Building Structures

Required Shear Reinforcements


2
Vm ax = V c + ( f c' .) A C V N
3

ϕ .V c A v
If V u ≤ ( ) = 0 .0
2 s
ϕ .V c
e ls e if ( < V u ≤ ϕ .V m a x ,
2
Av V u - ϕ .V c f c' b
= ≤ m ax ( .b w ; w )
s ϕ .f y s .d 4 .f y s 3 .f y s
e ls e if V u > ϕ .V m a x ,
a fa ilu re c o n d itio n is d e c la re d

Figure 4 - Transverse Reinforcement Requirements

Prof. Tavio, Ph.D. 7


RC14-1352 Concrete Building Structures

6db (≥75 mm)

Figure 5 - Hoop Reinforcement

2. Special Moment Frame Members


Subjected to Bending and Axial
Load
General Requirements
wSpecial moment frame members subjected to
bending and axial load must satisfy the
provisions of 23.4. These requirements are for
frame members in regions of high seismic risk or
for structures assigned to high seismic
performance or design categories. The
geometric constraints in 23
23.4.1,
4 1 which are
summarized in Table 7 and Fig. 6, follow from
previous practice.
wNote that any frame members in the structure
that do not satisfy 23.3.1 are to be proportioned
and detailed according to 23.4.

Prof. Tavio, Ph.D. 8


RC14-1352 Concrete Building Structures

Table 7 - General Requirements

300 mm

Figure 6 - General Requirements

Prof. Tavio, Ph.D. 9


RC14-1352 Concrete Building Structures

Longitudinal Reinforcement
based on Design Load Combinations

Prof. Tavio, Ph.D. 10


RC14-1352 Concrete Building Structures

Section Capacity with


Column Interaction Diagram

Prof. Tavio, Ph.D. 11


RC14-1352 Concrete Building Structures

Graphical view of the Capacity

Prof. Tavio, Ph.D. 12