6.0 Design Criteria 6.1 Dead Load Slab: Calculation Note For
6.0 Design Criteria 6.1 Dead Load Slab: Calculation Note For
WALL
Exterior Wall Full Grout (150 mm – 16.5 kN/m3 Density of Unit) 2.87 kPa
Interior Wall Full Grout (150 mm – 16.5 kN/m3 Density of Unit) 2.87 kPa
THIS DOCUMENT IS THE PROPERTY OF PROJECT NAME. IT MAY CONTAIN INFORMATION DESCRIBING TECHNOLOGY OWNED BY PROJECT NAME AND IS DEEMED TO BE
COMMERCIALLY SENSITIVE. IT IS TO BE USED ONLY IN CONNECTION WITH WORK PERFORMED BY PROJECT NAME.
LOGO CALCULATION NOTE FOR PROJECT NAME Rev 0
Occupancy Category I
Importance Factor 1.50
Zone 4
Seismic Zone Factor 0.4
Basic Seismic-Force Moment-Resisting Frame System
Resisting System Special Reinforced Concrete
Moment Frames
R 8.5
ΩO 2.8
Seismic Source Type B
Near Source Factor, Na 1.0
Near Source Factor, Nv 1.2
Soil Profile Type SD
Seismic Coefficient, Ca 0.44
Seismic Coefficient, Cv 0.768
Structure Type Reinforced Concrete Moment-
Resisting Frames
Ct 0.0731
Height of the Structure, hn 26
Structure Period 0.84168 s