instruments
ELEMENTAL
SPECTROSCOPY
PRODUCT BROCHURE
Analytical
Instruments
for
Science
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 4
Contents
PAGE NO.
Introduction 5
Detection Limits 7
AAWin2 Software 20
PFWin Software 31
Consumables 38
Analytical
Instruments
for
Science
3
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 5
4
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 6
l Burner Assembly
A hollow cathode lamp containing a coated cathode of
the element that is to be analysed is used as a light
l Optics
source. The light source emits a beam of a specific
wavelength through the flame and into the l Detector
5
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 7
57 58 59 75
76
60 61 62 63 64 65 66 67 68 69 70 71
Lanthanides
La Ce Pr Nd
Os
Re Pm Sm Eu Gd Tb Dy Ho Er Tm Yb Lu
89 90 91 107
108
92 93 94 95 96 97 98 99 100 101 102 103
Actinides
Ac Th Pa Bh
Hs
U Np Pu Am Cm Bk Cf Es Fm Md No Lr
Hydride Analysis
Flame Analysis
The hydride technique requires an additional unit to
Flame AAS is the standard technique used for general
add to the flame AAS system. The Hydride Generator is
purpose analysis. The readings are normally accepted to
used to produce a hydride vapour, for the hydride
be trace levels of ppm and nearly all elements can be
forming elements, by means of a heated tube which fits
analysed to this level. There is a choice of Air/Acetylene
directly to the top of the flame burner. The unit can also
flame used for easily ionised elements and Nitrous
be used for cold vapour technique primarily for Mercury
Oxide/Acetylene flame for the less easily excited
analysis. The hydride technique requires the following
elements. The flame technique requires a number of
extra components to complete the installation.
extra components to complete the installation.
l Pure Argon gas
l Oil free Air Compressor
l Suitable fume extraction system
l Ultra pure Acetylene Gas
l Autosampler (optional)
6
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 8
Detection limits
Element Wavelength Air/C2H2 N2O/C2H2/C2H2 Air/LPG Graphite Vapour
(nm) mg/l(ppm) mg/l(ppm) mg/l(ppm) µg/l(ppb) µg/l(ppb)
Aluminium (Al) 309.3 n/a 0.028 n/a 0.13 n/a
Antimony (Sb) 217.6 0.092 n/a 0.21 0.29 0.26
Arsenic (As) 193.7 0.12 n/a n/a 0.33 0.05
Barium (Ba) 553.6 n/a 0.031 n/a 0.23 n/a
Beryllium (Be) 234.9 n/a 0.0036 n/a 0.02 n/a
Bismuth (Bi) 223.1 0.0049 n/a 0.03 0.26 0.19
Boron (B) 249.7 n/a 3.5 n/a n/a n/a
Cadmium (Cd) 228.8 0.0028 n/a 0.008 0.01 n/a
Calcium (Ca) 422.7 n/a 0.0037 0.07 0.60 n/a
Chromium (Cr) 357.9 0.0054 n/a 0.6 0.025 n/a
Cobalt (Co) 240.7 0.01 n/a 0.018 2.00 n/a
Copper (Cu) 324.8 0.0045 n/a 0.0026 0.065 n/a
Dysprosium (Dy) 421.7 n/a 0.2 n/a n/a n/a
Europium (Eu) 459.4 n/a 0.04 n/a n/a n/a
Gold (Au) 242.8 0.013 n/a 0.026 3.00 n/a
Indium (In) 303.9 0.07 n/a 0.04 n/a n/a
Iron (Fe) 248.3 0.0043 n/a 0.015 0.06 n/a
Lead (Pb) 217.0 0.013 n/a 0.02 0.03 n/a
Lead (Pb) 283.3 0.016 n/a 0.04 0.08 n/a
Lithium (Li) 670.8 0.0021 n/a 0.004 0.70 n/a
Magnesium (Mn) 285.2 0.0022 n/a 0.002 0.09 n/a
Manganese (Mn) 279.5 0.0016 n/a 0.0019 0.03 n/a
Mercury (Hg) 253.7 n/a n/a n/a 40.0 0.15
Molybdenum(Mo) 313.3 n/a 0.021 n/a 0.14 n/a
Nickel (Ni) 232.0 0.008 n/a 0.012 0.065 n/a
Palladium (Pd) 247.6 0.03 n/a 0.018 0.04 n/a
Phosphorus (P) 213.6 n/a 10.0 n/a n/a n/a
Platinum (Pt) 265.9 0.12 n/a 0.22 0.04 n/a
Potassium (K) 766.5 0.0009 n/a 0.0041 0.40 n/a
Rhodium (Rh) 343.5 0.009 n/a 0.037 0.02 n/a
Rubidium (Rb) 780.0 0.003 n/a 0.005 n/a n/a
Scandium (Sc) 391.2 n/a 0.02 n/a n/a n/a
Selenium (Se) 196.0 0.23 n/a n/a 0.32 0.27
Silicon (Si) 251.6 n/a 0.30 n/a 17.0 n/a
Silver (Ag) 328.1 0.0032 n/a 0.0023 0.04 n/a
Sodium (Na) 589.0 0.0037 n/a 0.0086 n/a n/a
Strontium (Sr) 460.7 n/a 0.005 n/a 0.01 n/a
Tantalum (Ta) 271.5 n/a 2.2 n/a n/a n/a
Tellurium (Te) 214.3 0.054 n/a n/a 3.20 0.43
Thallium (Tl) 276.8 0.014 n/a n/a 0.015 n/a
Tin (Sn) 224.6 n/a 0.21 n/a 15.0 1.39
Titanium (Ti) 365.4 n/a 0.05 n/a 0.5 n/a
Tungsten (W) 255.1 n/a 1.2 n/a n/a n/a
Vanadium (V) 318.5 n/a 0.11 n/a 0.03 n/a
Zinc (Zn) 213.9 0.0033 n/a 0.0037 0.08 n/a
7
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 9
AA500
AT O M I C A B S O R P T I O N S P E C T R O M E T E R
8
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 10
U A om nt
N RA ABLion alys
Fu lti
PG IL at an
AV Aut leme
EW D E fo is
m
ll -e
u
E r
The AA500 Atomic Absorption Spectrometer is
a high performance automated instrument
designed to meet the requirements of the
modern laboratory. Due to its versatility and
performance it can be used for a wide range of
applications including:
l Agricultural l Clinical
l Environmental l Food
l Metal l Mining
l Geological l Petrochemical
l Pharmaceutical
9
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 11
AA500 continued
Air/Acetylene
F E AT U R E S & F U N C T I O N S
l The Air/Acetylene flame uses a 100mm single slot
l Embedded PC system built into the instrument as
burner for the standard configuration.
standard on all configurations. Pre-installed AAWin3
l The high sensitivity (Cu 2ppm >0.280abs) is due to
software, user manuals, cook book and Windows
the inert adjustable nebuliser fitted as standard.
operating system.
An acid resistant replacement is available with a
l AAWin3 software provides full control of the
Pt/Ir capillary.
instrument and autosampler with easy method
l The flame can be easily set from blue lean flame
change for each technique. Now GLP compliant.
through stoichiometric to fuel rich by means of
l Automatic 8 Hollow Cathode lamp turret controlled
computer control.
and optimised by the AAWin3 software. Operating
lamp current and warm-up lamp current can be N20/Acetylene
l The N2O/Acetylene flame uses a 50mm single slot
individually controlled to eliminate drift commonly
associated with lamp warming. burner and is available as an optional extra.
l D2 lamp background correction system fitted as
l This flame configuration is used to measure elements
standard to all configurations. High energy D2 lamp less prone to ionization such as: Aluminium, Tin,
and adjustable beam splitter mirror are optimised by Titanium, Calcium, Vanadium and Molybdenum.
the AAWin3 software.
l Switching from Air/Acetylene to N2O/Acetylene to
l Self Reversal background correction system fitted as
Flame Off is fully controlled by the AAWinPro
standard to all configurations. The high performance software.
background system uses the same hollow cathode
lamp as installed for the analysis. Minimum extra Air/Propane (LPG)
l This flame uses a 3 slot burner and with the low
components are required and optical alignment is
very simple. Self Reversal can be used for any element pressure requirement it is also much safer to operate.
at any wavelength making it extremely versatile.
l Due to the low temperature of the flame it is ideal for
l High precision minimal optics ensures maximum light
analysing alkali metals such as: Potassium, Sodium and
throughput to the computer controlled Czerny- Lithium, especially when used in the emission mode.
Turner monochromator.
l Some remote areas of the world have difficulty
l A universal autosampler is available as an optional
obtaining Acetylene gas of a high enough purity to
accessory which is conveniently mounted on the operate the flame correctly, LPG can give a real
front of the AA500 instrument. alternative and offer comparable results for most
l Optional XYZ autosampler provides appropriate elements throughout the wavelength range.
sample volume for multi element analysis, along with
scalable sample capacity for high sample throughput.
l Absorption and Emission modes are standard features
in the AAWin3 software as well as peak height, peak
area, sequential and manual integration modes.
F L A M E AT O M I S E R F E AT U R E S
The flame atomiser offers three flame options:
Air/acetylene is the standard configuration with the
N2O/acetylene and Air/LPG as options.
10
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 12
11
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 13
AAWin3 Software
AAWin3 Software is a powerful and intuitive software product designed to
allow control and data acquisition from the PG Instruments AA500 series
Atomic Absorption Spectrometer.
12
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 14
N
O
CO
G
W
M
LP
PL
IA
N
Full Automation for Multi-Element Analysis
T
Ensure optimal peak position at the chosen analytical
line by scanning the emissions spectra.
Use the sample table to perform quick measurements
of both Standards and Samples.
Easily append the sample table to add new samples or
even revise calibration curves either by manual
introduction or using an Autosampler.
For more details and ordering information please visit our website www.pginstruments.com 13
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 15
Specifications
Spectrometer System
Wavelength range 185nm - 910nm
Light Source Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
Modulation Square Wave Pulse
Modulation frequency 100hz Self reversal (SR) background, 400hz Deuterium Arc (D2) background
Monochromator
Grating 1800 grooves/mm diffraction grating
Blazed Wavelength 250nm
Focus 300nm
Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm (Software selectable)
Scan mode Automatic
Photometric Type Single Beam
Wavelength Accuracy +/-0.15nm
Wavelength Resolution 0.2nm +/-0.02nm
Wavelength Reproducibility < 0.05nm
Baseline Stability 0.005Abs/30min
Background Correction Deuterium Arc (D2) 1.0Abs, Self Reversal (SR) 3.0Abs
Flame Analysis
Flame Types Air/Acetylene, Nitrous Oxide/Acetylene, Air/Propane (LPG)
Sensitivity (Cu) 2µg/ml Absorption >0.280Abs
Characteristic Concentration Cu < 0.02µg/ml, Ba < 0.15µg/ml ( N2O/Acetylene)
Detection Limit Cu < 0.004µg/ml
Repeatability Cu < 0.7% (Air/Acetylene Flame)
Ba < 1.0% (Nitrous Oxide/Acetylene Flame)
Burner heads Titanium Alloy
Nebuliser Inert Adjustable Nebuliser, Flow Rate from 2ml - 6ml/min. Pt/Ir capillary
available for high acid concentration
Pre-mix Chamber Corrosion Resistant
Atomiser Selection Automatic changeover (AA500FG), Manual (AA500F)
Safety Features Burner identification, Flame Sensor, Gas Leak Sensor, Low Gas Pressure Sensor,
Drain Trap Sensor, Power Loss Protection
14
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 16
Specifications
Spectrometer System
Data Processing
PC System Embedded PC, Windows Professional Operating System
Operating Program AA Win Pro software
Analytical Methods Flame AA, Flame AE, Graphite Furnace, Hydride Generation
Readout Mode Continuous, Manual, Peak Height, Peak Area
Calibrations Multi-Standard Calibration, Standard Addition, Interpolation
Data Storage Analytical results, instrument and measurement parameters, signal profile,
calibration curve
Power Requirements
Main Unit 110/230Vac 50/60hz 200W
Graphite Power Supply 220Vac 50/60hz Instantaneous power 5KW Current rating??
Dimensions
Main unit 110cm x 54cm x 54cm 75Kg
Graphite Power Supply 50cm x 54cm x 54cm 70Kg
Standard packaging
AA500F AA500G AA500FG
1 Main unit 1 Main unit 1 Main unit
1 AA500F instruction Manual 1 AA500G instruction Manual 1 AA500F instruction Manual
1 Cook Book 1 Cook book 1 Cook Book
1 Safety Manual 1 Safety Manual 1 Safety Manual
1 System validation document 1 System Validation document 1 System validation document
1 Data coded Air/Acetylene 8 Hollow cathode Lamp 1 Data coded Air/Acetylene
burner Holders burner
1 Inert adjustable Nebuliser 1 Monitor 1 Inert adjustable Nebuliser
8 Hollow cathode Lamp Holders 1 Keyboard and Mouse 8 Hollow cathode Lamp
1 Monitor 1 Low Voltage Power Supply Holders
1 Keyboard and Mouse 2 Power Cables 1 Monitor
1 Low Voltage power Supply 1 Tool Kit 1 Keyboard and Mouse
2 Power Cables 1 Various Gas Fittings 1 Low Voltage power Supply
1 Gas tubing Air 10 Graphite Tubes 2 Power Cables
1 Gas Tubing Acetylene 1 Gas Tubing Argon 1 Gas tubing Air
1 Drain Trap and Tubing 1 Connection Cable (Graphite) 1 Gas Tubing Acetylene
1 Tool Kit 1 Pipette 1 Drain Trap and Tubing
1 Various gas Fittings 1bag Pipette Tips 1 Tool Kit
1 Various gas Fittings
10 Graphite tubes
1 Gas Tubing Argon
1 Connection Cable (graphite)
1 Pipette
1bag Pipette Tips
15
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 17
Accessories
Autosampler (500-004)
The AS500 Autosampler is an accessory specifically designed for the AA500 Atomic Absorption Spectrometer.
The AS500 can be used to automatically introduce standard and unknown samples to the atomiser for analysis.
It can be used with both flame and graphite furnace instruments.
Flame Analysis
l 38 sample positions (6 for standard samples, 32 for unknown
samples).
l Sample vial size 6ml
l Standard sample vial size 12ml
l Pressure protection for wash
l Position adjustment by AA Win software
l Reproducibility Cu < 0.6% (air/acetylene) Cu< 1.0% (air/LPG)
Ba <1.0% (nitrous oxide/acetylene)
Graphite Analysis
l 76 sample positions (10 for standard samples, 6 for modifier
solutions, 60 for unknown samples)
l Sample vial size 1.5ml
l Modifier vial size 12ml
l Pressure protection for wash
l Up to 3 modifier additions
l Position adjustments by AA-Win Pro software
l Reproducibility Cu <2.0%, Cd <2.0%
16 For more details and ordering information please visit our website www.pginstruments.com
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 18
For more details and ordering information please visit our website www.pginstruments.com 17
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 19
AA990F
AT O M I C A B S O R P T I O N S P E C T R O M E T E R
18
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 20
F E AT U R E S & F U N C T I O N S
l The instrument has a motorised 8 hollow cathode
lamp turret which allows the automatic positioning
and optimisation of each hollow cathode lamp by
the software.
l The control of the gas flows for the fuel gas (C2H2) of
the burner is also carried out directly from the software
thus allowing optimisation of the instrument for the
best analytical parameters for a selected analysis.
l Two methods of background correction are available.
The first utilises a Deuterium Arc lamp and the second
is the proven method of Self Reversal.
l High precision minimal optics ensures maximum light
throughput to the computer controlled Czerny-Turner
Monochromator.
l The location of the wavelength and peak selection is
automatically controlled from the software.
l The spectral bandwidth is automated and is available
with a choice of five slit sizes.
l The electronic parameters for the photomultiplier tube
detector, the hollow cathode lamp current and the
balancing of the absorbance and background energies
are controlled from the software.
l The ignition of the flame is computer controlled
and the various safety interlocks offer a very safe
operating system.
SAFETY
l The flame conditions are continuously monitored and
should the flow rates change, an audible alarm sounds.
l The pressure of the support gas (oxidant) is monitored
constantly. If the pressure changes then the flow of
the fuel gas will be stopped and the flame will be
safely extinguished.
l A sensor monitors the level of liquid in the drain
and will prevent ignition if too low. The flame will also
be extinguished if the level of liquid in the drain
changes significantly.
l A flame sensor monitors the flame and safely turns off the
gas flow to the burner if the flame suddenly extinguishes.
l The burner is identified by a switch making it
impossible to light without the burner being fitted.
l An emergency flame off button is installed in case a
problem is observed. The flame can be extinguished
safely.
19
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 21
AAWin2 Software
AAWin2 Software is a powerful and intuitive software product designed to
allow control and data acquisition from the PG Instruments PG990 Atomic
Absorption Spectrometer.
20
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 22
For more details and ordering information please visit our website www.pginstruments.com 21
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 23
Specifications
Spectrometer system
Wavelength range 190nm - 900nm
Light Source Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
Modulation Square Wave Pulse
Modulation frequency 100hz Self reversal (SR) background, 400hz Deuterium Arc (D2) background
Monochromator
Grating 1800 grooves/mm diffraction grating
Blazed Wavelength 250nm
Focus 300nm
Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm (Software selectable)
Scan mode Automatic
Photometric Type Single Beam
Wavelength Accuracy +/-0.15nm
Wavelength Resolution 0.2nm +/-0.02nm
Wavelength Reproducibility < 0.05nm
Baseline Stability 0.005Abs/30min
Background Correction Deuterium Arc (D2) 1.0Abs, Self Reversal (SR) 3.0Abs
Flame Analysis
Flame Type Air/Acetylene
Sensitivity (Cu) 2ug/ml Absorption >0.28Abs
Characteristic Concentration Cu < 0.02ug/ml
Detection Limit Cu < 0.004ug/ml
Repeatability Cu < 0.7%
Burner head Titanium Alloy
Nebuliser Inert Adjustable Nebuliser, Flow Rate from 2ml - 6ml/min. Pt/Ir capillary
available for high acid concentration
Pre-mix Chamber Corrosion Resistant
Safety Functions Burner switch, Flame Sensor, Gas Leak Sensor, Low Gas Pressure Sensor,
Drain Trap Sensor, Power Loss Protection
Data Processing
Operating Program AA Win software
Analytical Methods Flame AA, Flame AE, Hydride
Readout Mode Continuous, Manual, Peak Height, Peak Area
Calibrations Multi-Standard Calibration, Standard Addition, Interpolation
Data Storage Analytical results, Instrument and measurement parameters, Signal profile,
Calibration curve
Power Requirements 220Vac 50/60hz 200W
Dimensions 110cm x 54cm x 54cm 75Kg
Standard packaging
1 Main Unit 1 Air/Acetylene Burner 1 Gas Tubing Acetylene
1 PG990 Instruction Manual 1 Inert Adjustable Nebuliser 1 Drain Trap and Tubing
1 Cook Book 8 Hollow Cathode Lamp Holders 1 Tool Kit
1 Safety Manual 1 Power Cable 1 Various Gas Fittings
1 System Validation Document 1 Gas Tubing Air
22
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 24
Accessories
Inert Adjustable Nebuliser (500-011) Flame Autosampler
l Excellent RSD’s typically samples and calibration
Patent pending
<1.0% standards.
l Typical read back values l The system allows for
better than 2% automatic update of
l Enhanced sensitivity standard values and curve
l Can be used on all PG parameters by using up
Instruments AA500 and to 8 standards, blanks
l Acid resistant nebuliser
AA990 series atomic and QC standards.
with Pt/Ir capillary (500-012)
absorption systems l A double wash station
l Adjustable uptake from
l Redesigned spray chamber for probe wash avoids
2-6ml/min
to ensure excellent sample and standard
l Fully adjustable impact
drainage properties l Sequential auto-sampler contamination.
bead
allows the automated l An inert Teflon probe is
analysis of 50 or more supplied as standard.
Hydride Unit (990-007)
l Supplied with
temperature controlled Air Compressor (GS-003)
heated absorption cell l Efficient, Horizontal Twin
l Cell is easily installed with pump unit
burner attachment l Innovative Compact
l Can be used for Mercury Design, perfect for
cold vapour analysis limited space
l Sensitivity for most l 10 bar Maximum pressure
elements <1ng/ml l 15 Litre tank for stable air
l Only 2.0ml – 2.5ml per l Ultra low noise when supply
sample required running – just 53-59dB (A) l 104L/min supply at 3 bar
l Universal design l RSD < 3% l 100% Oil Free Design l Easy to ship only 14Kg
l Full reaction cycle from l Quick analysis < 30
press of start button seconds per measurement
For more details and ordering information please visit our website www.pginstruments.com 23
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 25
24
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 26
accuracy.
l Qualification Workbook.
25
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 27
Atomic Fluoresc
Spectroscopy
26
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 28
27
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 29
AF402
S I M U LTA N E O U S AT O M I C
FLUORESCENCE SPECTROMETER
28
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 30
S TA N D A R D F E AT U R E S
Light Source
l High Intensity Hollow Cathode lamps for greater
intensity and stability.
l Up to three lamps can be installed for simultaneous
analysis.
l All lamps are uniquely data coded offering important
information to the PF Win operating software.
Optical System
l Shielded optical design greatly reduces light interference.
Atomiser System
l High precision quartz atomiser tube designed for
optimum performance, durability and long life.
l Self-igniting Argon/ Hydrogen flame with software
controlled heater coil.
l Adjustable height control for improved optimisation.
29
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 31
AF402
Hydride generator
continued
Autosampler
l Integrated autosampler.
l XYZ configuration.
Detection Limits
Element Detection Limit(ug/l) RSD %
Arsenic (As) <0.01ug/l <1%
Bismuth (Bi) <0.01ug/l <1%
Cadmium (Cd) <0.001ug/l <1%
Germanium (Ge) <0.05ug/l <1%
Mercury Hg) <0.001ug/l <1%
Lead (Pb) <0.01ug/l <1%
Antimony (Sb) <0.01ug/l <1%
Selenium (Se) <0.01ug/l <1%
Tin (Sn) <0.01ug/l <1%
Tellurium (Te) <0.01ug/l <1%
Zinc (Zn) <1.0ug/l <1%
30
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 32
PFWinSoftware
The intuitive software package provides ease of
operation, method development control and data
acquisition. Software wizards simplify the operation
and configuration.
31
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 33
Specifications
Sample Atomisation
Atomiser Quartz tube furnace with auto ignition of argon/hydrogen flame
Furnace heating Computer controlled heating
Hydride Generator Continuous flow high performance for cold-vapour mercury and hydride
determinations of As, Se, Te, Bi, Sb, Sn, Zn, Pb, Cd, Ge
Gas Requirement High purity Argon gas(99.99%) 30psi pressure
Autosampler
Type Integrated XYZ
Sample Introduction High sample capacity, automated introduction of sample and standards by
motorised syringe drive.
Sample capacity 2 x 45 standard test tube sample racks
Optics
Optical Design Short focal length, non-dispersive integrated optical design.
Light source 3 channel simultaneous element analysis using computer controlled.
Modulated and pulsed, hollow cathode light source.
Baseline stability <2%
Linear range >103
Computer system
Type Built in embedded PC system
Operating system Windows
Operating software PFWin software
Safety Alarm for low gas <60ml/min. Gas cut off in the event of power supply loss
Power requirements 220Vac ±10% 50/60hz, 300W
Dimensions 100.6cm x 58cm x 55cm
32
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 34
Accessories
Argon Gas Regulator
l Direct fitting to gas cylinder
l 240Vac 50/60hz
For more details and ordering information please visit our website www.pginstruments.com 33
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 35
FP902
FLAME PHOTOMETER
34
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 36
NW U
BA
O ITH M
W
RI
Flame photometry provides a simple method
of analysis and concentration determination of
elements which cannot easily be measured
using any other technique. PG Instruments
application notes for users of our versatile
new flame photometers cover a wide range
of industrial sectors, from food and drink to
cement, minerals and glass, as well as
agricultural, biological and clinical applications.
The FP902 uses a soft touch key pad for ease of data entry
and features electronic ignition, automatic flame failure
safety and will operate using butane, natural gas or LPG.
35
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 37
T Y P I C A L A P P L I C AT I O N S
l Soil and Agricultural Analysis
l Biological Fluids
l Petrochemical Industry
F E AT U R E S & F U N C T I O N S
l Five element measurement in a single aspiration
(Na, K, Li, Ca and Ba).
l Curve calibration using up to 5 standards.
l Printer attachment.
36
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 38
Specifications
General Analytical
Mode Applications Serum Urine
Compressor Unit
Air Supply Oil free compressor unit with pressure regulator
Combustion Gas LPG Controlled by precision regulator
Power 230 V + 10% AC, 50/60 Hz
Dimensions 290 x 255 x 210 mm (L x B x H) (Approx)
Weight 8Kg. (Approx.)
37
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 39
Consumables
AA500
Hollow Cathode Lamps Multi Element Standards
l 2 inch lamps available l 500ml volume bottles
l 70 single-element lamps l More than 40 individual
l More than 120 multi elements available
element lamps, up to l 1.000g/ml (1000ppm)
5 element per lamp concentration
l Low current operation l Individual elements made
l Long life >5000mA Hours up in a choice of acid
l 11/2 inch standard lamp l Designed for use with SR solutions
fitting background system
38
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 40
Consumables
AA500
Auto Sampler Vials – Flame Standards Auto Sampler Vials – Graphite Samples/Standards
l Re-useable glass vials l Re-usable vials
l For use with AS500 Auto l For use with AS500
Sampler autosampler
l Larger volume for l 1.5ml volume for samples
standards 12ml and standards
39
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 41
Consumables
AA990
Hollow Cathode Lamps Multi Element Standards
l 2 inch lamps available l 500ml volume bottles
l 70 single-element lamps l More than 40 individual
l More than 120 multi elements available
element lamps, up to l 1000g/ml (1000ppm)
5 element per lamp concentration
l Low current operation l Individual elements made
l Long life >5000mA Hours up in a choice of acid
l 11/2 inch standard lamp l Designed for use with SR solutions
fitting background system
40
AA SPEC BRO – 060_Layout 1 09/10/2013 12:43 Page 42
Consumables
AF402
Hollow Cathode Lamps Quartz Atomiser
l High performance – High l Quartz Glass – to
output lamps withstand heat and
l Lamps designed for use chemicals
with AF402 system l Replacement required at
l Built in circuit for coding regular intervals
and usage recording l Inputs for gas and hydride
l Available for analysis of a vapout
variety of elements
including: Sb, As, Bi, Cd,
Ge, Pb, Hg, Se, Te, Sn, Zn
41
AA SPEC BRO – 060_Layout 1 09/10/2013 12:43 Page 43
Consumables
FP902
Air Compressor Nebuliser
l Matching air compressor l Cross flow design
l Adjustable uptake rate
designed only for use with
42
AA SPEC BRO – 060_Layout 1 09/10/2013 12:43 Page 44
We reserve the right to modify, revise/upgrade, suspend or discontinue any Product in whole or in part,
either temporarily or permanently, with or without notice.