Professional Documents
Culture Documents
GeoTalk VI Sindhu
GeoTalk VI Sindhu
GeoTalk VI Sindhu
by
SINDHU RUDIANTO
PT GE0-PRIMA
Project Plan
Presentation
Reduction Factor () versus quc Reduction Factor () versus Rock
Mass (after Tomlinson, 1995)
• RQD = 40% design UCS = 24 Mpa
• α = 0.07, β = 0.65
• Rock socket friction (fs) = 0.07 x 0.65 x 24,000 = 1,092 kPa.
• This is consistent with local practice, where (fs) is 5% of unconfined
compressive strength of rock or concrete, whichever is less.
• For limestone with UCS = 24 MPa and concrete grade 60 with UCS = 60 MPa
(cube strength), the computed fs = 0.05 x 24,000 = 1,200 kPa.
Pile Design Criteria
Aging effect
bentonite pile
D = 100 cm
Leff = 53 m
Residual Load Instrumented pile
Jacked pile
1. Memakai rumus driven pile > Ref. Tomlinson
2. Gaya jacking > 2 DL (2.5x DL kalau memakai dolly, 2.3
DL kalau tidak).
3. Memastikan gaya jacking refusal (ditekan max. jack load
3 x berturut-turut, sett < 10 mm.
4. Masalah utama “ heave” dalam jacking group pile besar.
Survey kepala tiang dalam radius sepanjang tiang. Kalau
heave > 15-25 mm, rejack ulang. Jika memakai dolly,
survey dan rejacking sulit dilakukan.
5. Sambungan splice dari jacked pile harus diperhatikan
jika desain tiang menahan tarik.
Load-Movement at Pile Top
(D = 80 cm, Leff = 39 m)
Efek Residual Load
(D = 80 cm, Leff = 39 m)
Thanks and Questions