Professional Documents
Culture Documents
EN 795 - Horizontal Lifeline Prediction Sheet: Input Data Design Loads
EN 795 - Horizontal Lifeline Prediction Sheet: Input Data Design Loads
EN 795 - Horizontal Lifeline Prediction Sheet: Input Data Design Loads
2 | October 2018
Intermediate Supports
35 daN
35 daN
Results & System Design Check Summary
Date : 12-Oct-19
Key Dimensions
A 12 m
B 6 m
C 0.45 m
D 0.81 m
B
Lifeline Deflection 0.92 m
A Cable Tension 45.2 kN
Ø1 60.9 °
Ø2 81.3 °
Walkway Width 1 m
C
Forces on Brackets
B (unfactored)
Fx 44.7 kN
Lifeline Fy 6.0 kN
deflection Fz 3.3 kN
D
Factored Loads
Fx 53.6 kN
Fy 7.2 kN
Fz 4.0 kN
Max Shear Fx = 53.64kN (ULS) + Fy Component of shear = 7.2kN (ULS) = resultant shear force of 54.1kN (ULS)
Max Tension = 3.96kN (ULS)
Max Load per bolt Capacity of M16 Grade 8.8 Bolts Bolt Utilisation 0.49 Pass
Tension 1.98 Tension 70.3 0.03
Shear 27.05 Shear 58.9 0.46
Bracket Utilisation 0.63 Pass
Bracket Strength (Maximum Shear Force) 85.4 kN 0.63
Max shear Fy = 7.2kN (ULS) Full load resisted by one M12 Grade 8.8 Bolt.
Max Tension Fz = 3.96kN (ULS)
Max Load per bolt Capacity of an M12 Grade 8.8 Bolt Bolt Utilisation 0.33 Pass
Tension 4.0 Tension 37.8 0.10
Shear 7.2 Shear 31.6 0.23
Bracket Utilisation 0.14 Pass
Bracket Tensile Strength 28.0 kN 0.14
Maximum cable tension = 44.7kN (SLS) the capacity of the cable is 85.4kN (ULS)
Note: EAD (if used) does not need checking, as it will become a cable once fully deployed.
Check the safe fall distance based on the lifleine prediction, considering the width of the walkway.
D = Vertical deflection of lifeline 0.81 m
E = Length of Lanyard 1.80 m
D F = Length of Harness + Absorber 3.55 m
H G = Clear Distance from floor 5.64 m
H = Height of Lifeline above walkway 1.8 m
J = Height of walkway above floor 10 m
E K = Clear Distance from obstacles 0.64 m
L = Obstacle Height 5.00 m
Width of
Walkway
F
J Deflection is Safe for User
K
G
L
OVERALL DESIGN CHECK RESULTS: SYSTEM DESIGN IS SAFE