EN 795 - Horizontal Lifeline Prediction Sheet: Input Data Design Loads

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Version 5.

2 | October 2018

EN 795 - Horizontal Lifeline Prediction Sheet Sheet 1 of 2


6 kN + 6 kN + 1 kN Ø12 mm STAINLESS STEEL CABLE SYSTEM

Input Data Design Loads


System type (Single Span/Multispan) MULTISPAN 9 No of Intermediate Supports 2
End Support Load 22.6 kN 22.6
0 No of Energy Absorbers 0 14 Applied Loading to EN 795 14.0 kN

Number of men on system v


Min Breaking Load for Cable 85.4 kN Fall Height Values (m)
Wire Factor of Safety 2.0 Height of wire above catwalk 1.8
Allowable Min Obstacle Clearance 5.00 m Width of catwalk 1
Bracket Factor Of Safety 2.0 Height of catwalk above floor 10
Design Strength of End Bracket/ fixings 85.4 kN
Design Strength of Intermediate Bracket 28.0 kN

Total Cable Length 36.0 m


Total Cable Extension 0.28 m
Max. Span (m) Min. Span (m)
12.0 0

Intermediate Supports

End Anchor Support End Anchor Support


T T
T
Max Cable Sag 0.92 1.24
7 daN
Length of Lanyard 1.80
Tension (T) at End Support 34.7 kN Length of Shock Absorber 1.75
Length of Harness 1.80
11.8 (back dorsal attachment to feet)
Height of cable above floor (m) Fall Load 14.0 kN Maximum Fall = 6.27 m
Floor Clearance height = 5.64 m
Obstacle Clearance Height = 0.64 m

35 daN

35 daN
Results & System Design Check Summary

Description Criteria Status Result Utilisation Ratio


Fall in Maximum Span (Max Cable Tension) 2 x Predicted Results Pass 45.2 kN 0.53
Fall in Minimum Span (Max Cable Tension) 2 x Predicted Results #N/A #N/A #N/A
Maximum Cable Tension 85.4 kN Pass 45.2 kN 0.53
Fall height safe by 0.641 metres high
Obstacle Clearance is greater than 5.00 m Pass N/A
above obstacle
Mid Bracket Fixing Check Pass Use 1 x M12 Gr.8.8 Bolt 0.33
Mid Bracket Strength Check Pass Use Standard RRGB Mid Bracket 0.14
End Bracket Fixing Check Pass Use 2 x M16 Gr.8.8 Bolts 0.49
End Bracket Strength Check Pass Use Standard RRGB End Bracket 0.63
If supporting structure cannot withstand end
anchor and/or intermediate loads then If < 33 kN fit 1 EAD.
N/A
consider fitting 1 or 2 EAD's. If > 33 kN fit 2 EAD's.

SYSTEM DESIGN IS SAFE


Client : ESI

Job Number : Revision:

Date : 12-Oct-19

Written By: Approved By:

Notes & Recommendations

STE017-5.2 MR 24/10/2018 Date printed 12-Oct-19 Time printed 9:41 AM


Version 5.1 | May 2015

EN 795 - Horizontal Lifeline Prediction Sheet Sheet 2 of 2


6 kN + 6 kN + 1 kN Ø12 mm STAINLESS STEEL CABLE SYSTEM

Loads on the System

Key Dimensions
A 12 m
B 6 m
C 0.45 m
D 0.81 m
B
Lifeline Deflection 0.92 m
A Cable Tension 45.2 kN
Ø1 60.9 °
Ø2 81.3 °
Walkway Width 1 m
C
Forces on Brackets
B (unfactored)
Fx 44.7 kN
Lifeline Fy 6.0 kN
deflection Fz 3.3 kN
D
Factored Loads

Fx 53.6 kN
Fy 7.2 kN
Fz 4.0 kN

Strength Check - End Bracket

Max Shear Fx = 53.64kN (ULS) + Fy Component of shear = 7.2kN (ULS) = resultant shear force of 54.1kN (ULS)
Max Tension = 3.96kN (ULS)

Max Load per bolt Capacity of M16 Grade 8.8 Bolts Bolt Utilisation 0.49 Pass
Tension 1.98 Tension 70.3 0.03
Shear 27.05 Shear 58.9 0.46
Bracket Utilisation 0.63 Pass
Bracket Strength (Maximum Shear Force) 85.4 kN 0.63

Strength Check - Mid Bracket

Max shear Fy = 7.2kN (ULS) Full load resisted by one M12 Grade 8.8 Bolt.
Max Tension Fz = 3.96kN (ULS)

Max Load per bolt Capacity of an M12 Grade 8.8 Bolt Bolt Utilisation 0.33 Pass
Tension 4.0 Tension 37.8 0.10
Shear 7.2 Shear 31.6 0.23
Bracket Utilisation 0.14 Pass
Bracket Tensile Strength 28.0 kN 0.14

Strength Check - Cable

Maximum cable tension = 44.7kN (SLS) the capacity of the cable is 85.4kN (ULS)

Utilisation of cable under applied loading Cable Utilisation 0.53 Pass

Note: EAD (if used) does not need checking, as it will become a cable once fully deployed.

Serviceability Check - Fall Height & Clearance

Check the safe fall distance based on the lifleine prediction, considering the width of the walkway.
D = Vertical deflection of lifeline 0.81 m
E = Length of Lanyard 1.80 m
D F = Length of Harness + Absorber 3.55 m
H G = Clear Distance from floor 5.64 m
H = Height of Lifeline above walkway 1.8 m
J = Height of walkway above floor 10 m
E K = Clear Distance from obstacles 0.64 m
L = Obstacle Height 5.00 m

Width of
Walkway
F
J Deflection is Safe for User

K
G
L
OVERALL DESIGN CHECK RESULTS: SYSTEM DESIGN IS SAFE

STE017-5.2 MR 24/10/2018 Date printed 12-Oct-19 Time printed 9:41 AM