D E S C R I P T I O N
T E C H N O L O G Y
• Comprehensive diagnostics with faults, warnings & E3 MODULEVEL is capable of tracking the interface
status history level of two immiscible liquids with different densities.
Each unit is custom-made with a displacer specially
• HART or FOUNDATION fieldbus digital communications
designed for the user’s application. This allows it to
• PACTware PC program using HART communication detect the position of a clean interface or an emulsion
for advanced configuration and troubleshooting layer and convert it into a stable 4 –20 mA signal. Contact
(see bulletin 59-101) the factory for assistance in specifying an E3 for interface
• IS, XP and Non-incendive approvals by FM, CSA, service. Note that for proper interface detection, the
ATEX, IEC entire displacer must always be immersed in liquid.
• Standard output range from 3.8 to 20.5 mA
• 11 VDC turn on voltage D E N S I T Y
• Maximum loop resistance of 620 ohms at 24 VDC Yet another capability of E3 MODULEVEL is to track the
• Process temperatures to +850 °F (+454 °C) for changing density of a liquid over a known density range
non-steam applications and convert that into a stable 4–20 mA output signal.
As the density of the liquid changes, so does the mass
• Level ranges from 14 to 120+ inches
of the liquid displaced by the specially designed dis-
(356 to 3048+ mm)
placer. The resulting change in buoyancy force on the
• Specific gravity as low as 0.23 displacer causes the movement of the LVDT core nec-
• Cast aluminum or stainless steel, TYPE 4X, essary to convert the density change to the 4–20 mA
Cl I Div 1 Groups B, C, D housing signal.
5
D I M E N S I O N A L S P E C I F I C A T I O N S
STANDARD PRESSURE MODELS E3A, E3B, E3C, E3D, E3E, E3F
I N C H E S ( M M )
D C
2.81 3.86
0.87 (71) (98)
(22)
Level range
H 3.95
(100)
6.28
(159)
10.32
J (262) 8.10
(206)
4.04
(103) 70°
E
Dia.
F
HT Integral Side/Bottom Mount E3A/E3B Series with Integral Top Mounting Integral Transmitter Head
Fourth Digit Codes A, B, C Fourth Digit Codes J, K, L
2.84 502
(72) (128)
3.99
¾" NPT Dual Conduit Entries
(101)
K 3.96 (101)
8.73
(222)
5.31 5.42
15.95 3.85 (135) (138) 15.95
(405) (98) 45° (405)
A minus 3.34 (85)
A minus 3.34 (85) 6.25 (159)
6.48
(165)
D D
4.02 2.39
(102) (61)
(121) (186) (186) (84) (181) (76) (76 + range) (138) (262)
4.75 7.31 7.31 3.31 7.13 3.00 3.00 + range 5.43 10.32
1.10 – 2.20
(121) (186) (186) (84) (181) (76) (76 + range) (138) (262)
6.75 9.31 9.31 3.19 7.00 3.00 3.00 + range 5.43 10.32
11⁄2" 0.55 – 1.09
(171) (236) (236) (81) (178) (76) (76 + range) (138) (262)
900# ANSI
6.75 9.31 9.31 3.31 7.13 3.00 3.00 + range 5.43 10.32
2" 0.55 – 1.09
(171) (236) (236) (84) (181) (76) (76 + range) (138) (262)
6.75 9.31 9.31 3.19 7.00 3.44 3.44 + range 6.43 10.32
11⁄2" 0.55 – 1.09
(171) (236) (236) (81) (178) (87) (87 + range) (163) (262)
1500# ANSI
6.75 9.31 9.31 3.31 8.13 3.44 3.44 + range 7.43 10.32
2" 0.55 – 1.09
(171) (236) (236) (84) (207) (87) (87 + range) (189) (262)
6.75 9.31 9.31 4.00 9.00 3.44 3.44 + range 10.21 10.32
11⁄2" 0.55 – 1.09
(171) (236) (236) (102) (229) (87) (87 + range) (259) (262)
2500# ANSI
6.75 9.31 9.31 4.38 9.81 3.44 3.44 + range 11.08 10.32
2" 0.55 – 1.09
(171) (236) (236) (111) (249) (87) (87 + range) (281) (262)
8.25 9.31 9.31 3.19 7.00 3.00 3.00 + range 5.43 11.60
11⁄2" 0.55 – 1.09
150#, 300# & (210) (236) (236) (81) (178) (76) (76 + range) (138) (295)
600# 8.25 9.31 9.31 3.31 7.13 3.00 3.00 + range 5.43 11.60
2" 0.55 – 1.09
(210) (236) (236) (84) (181) (76) (76 + range) (138) (295)
8.25 9.31 9.31 3.19 7.00 3.00 3.00 + range 5.43 11.60
11⁄2" 0.55 – 1.09
(210) (236) (236) (81) (178) (76) (76 + range) (138) (295)
900#
8.25 9.31 9.31 3.31 7.13 3.00 3.00 + range 5.43 11.60
2" 0.55 – 1.09
(210) (236) (236) (84) (181) (76) (76 + range) (138) (295)
8 8.25 9.31 9.31 3.19 7.00 3.44 3.44 + range 6.43 11.60
11⁄2" 0.55 – 1.09
(210) (236) (236) (81) (178) (87) (87 + range) (163) (295)
1500#
8.25 9.31 9.31 3.31 8.13 3.44 3.44 + range 7.43 11.60
2" 0.55 – 1.09
(210) (236) (236) (84) (207) (87) (87 + range) (189) (295)
8.25 9.31 9.31 4.00 9.00 3.44 3.44 + range 1021 11.60
11⁄2" 0.55 – 1.09
(210) (236) (236) (102) (229) (87) (87 + range) (259) (295)
2500#
8.25 9.31 9.31 4.38 9.81 3.44 3.44 + range 11.08 11.60
2" 0.55 – 1.09
(210) (236) (236) (111) (249) (87) (87 + range) (281) (295)
7
N O N - S T E A M S E R V I C E
M O D E L N U M B E R
Models available for quick shipment, usually within one week after factory
receipt of a complete purchase order, through the Expedite Ship Plan (ESP).
DESIGN TYPE
E3 Standard Construction Electronic MODULEVEL
LEVEL RANGE
All Pressures / 9th Digit = 8 600# and below
14 32 48 60 72 84 96 108 120 Inches
356 813 1219 1524 1829 2134 2438 2743 3048 mm
A B C D E F G H I Code
E 3
8
N O N - S T E A M S E R V I C E
M O D E L N U M B E R
SIGNAL OUTPUT
F FOUNDATION fieldbus™ Digital Communications (English only)
S 4–20 mA/HART, SIL 2/3 Certified
MOUNTING/TEMPERATURE
Integral Mount
Use with Specific Gravity and
Maximum Process Temperature
Process Temperature codes (4th Digit):
1 +550 °F (+290 °C) J, K, L, A, B, C, M, N, P, D, E, F
3 +551 to +600 °F (+291 to +315 °C) M, N, P
Remote Mount ∆
Use with Specific Gravity and
Maximum Process Temperature
Process Temperature codes:
4 +550 °F (+290 °C) J, K, L, A, B, C, M, N, P, D, E, F
6 +551 to +600 °F (+291 to +315 °C) M, N, P
8 +601 to +850 °F (+316 to +454 °C) E, N
∆ Cable for remote mounting transmitter is 037-3226-xxx up to +400 °F (+204 °C) and
037-3227-xxx (Belden 88777) above +400 °F (+204 °C) where -xxx is the length in
feet from 10 (-010) to 400 (-400) feet.
E 3
9
S T E A M S E R V I C E
M O D E L N U M B E R
DESIGN TYPE
E3 Standard Construction Electronic MODULEVEL
LEVEL RANGE
All Pressures / 9th Digit = 8 600# and below
14 32 48 60 72 84 96 108 120 Inches
356 813 1219 1524 1829 2134 2438 2743 3048 mm
A B C D E F G H I Code
E 3
10
S T E A M S E R V I C E
M O D E L N U M B E R
SIGNAL OUTPUT
F FOUNDATION fieldbus™ Digital Communications (English only)
S 4–20 mA/HART, SIL 2/3 Certified
MOUNTING/TEMPERATURE
Integral Mount
Use with Specific Gravity and
Maximum Process Temperature
Process Temperature codes (4th Digit):
1 +300 °F (+150 °C) K
2 +301 to +450 °F (+151 to +230 °C) B, N
3 +451 to +500 °F (+231 to +260 °C) E
Remote Mount ≈
Use with Specific Gravity and
Maximum Process Temperature
Process Temperature codes (4th Digit):
4 +300 °F (+150 °C) K
5 +301 to +450 °F (+151 to +230 °C) B, K, N
6 +451 to +500 °F (+231 to +260 °C) E, N
8 +501 to +800 °F (+261 to +427 °C) E, N ∆
≈ Cable for remote mounting transmitter is 037-3226-xxx up to +400 °F (+204 °C) and
037-3227-xxx (Belden 88777) above +400 °F (+204 °C) where -xxx is the length in feet
from 10 (-010) to 400 (-400) feet.
∆ 4th digit N with 9th digit 8 has a maximum temperature of +700 °F (+371 °C).
E 3
11
Q U A L I T Y
The quality assurance system in place at The MAGNETROL quality assurance system
Magnetrol® guarantees the highest level of is registered to ISO 9001 affirming its com-
quality throughout the company. MAGNETROL mitment to known international quality
is committed to providing full customer standards providing the strongest assurance
satisfaction both in quality products and of product/service quality available.
quality service.
E S P
Several Electronic MODULEVEL Displacer To take advantage of ESP, simply match the
Expedite
Transmitters are available for quick ship- color coded model number codes (standard
ment, usually within one week after factory dimensions apply).
Plan
units or more. Contact your local representa-
Models covered by ESP service are color tive for lead times on larger volume orders,
coded in the selection data charts. as well as other products and options.
W A R R A N T Y
All MAGNETROL electronic level and flow control at no cost to the purchaser (or
controls are warranted free of defects in ma- owner) other than transportation.
terials or workmanship for eighteen months MAGNETROL shall not be liable for misap-
from the date of original factory shipment. plication, labor claims, direct or consequen-
If returned within the warranty period; and, tial damage or expense arising from the
upon factory inspection of the control, the installation or use of equipment. There are
cause of the claim is determined to be no other warranties expressed or implied,
covered under the warranty; then, except special written warranties covering
MAGNETROL will repair or replace the some MAGNETROL products.
Magnetrol, Magnetrol logotype and Modulevel are registered trademarks of Magnetrol International, Incorporated. BULLETIN: 48-135.10
EFFECTIVE: August 2017
SUPERSEDES: October 2016