Mounting of Test Connectors

Choose the test connector according


to your need. USB 2.0 test connector holder
in this example. test connector

connector

Align the median level of the


connector to be tested and of the
test connector.
test connector
alignment of
the levels

connector

Align the lower level of the test connector test connector


connector to the lower internal level
of the connector to be tested.

alignment of
the levels

Edition 11/2016. All rights reserved. not all combinations are available. Further version can be found at www.feinmetall.com
Mounting of Test Connectors

Place two M3 holes face to face on


the back plate. Two CHC M3x8 screws
are needed to fix the holding device drill hole M3
with the test connector.

back plate

drill hole M3

Make a sufficient cut to push the


test conenctor through to the back. drill hole M3
Plan at least 1 mm of space between
notch and test connector.

notch for
connector
notch for
connector
drill hole M3

For mounting the test connector


loosen the retaining screw. Insert the
test connector into the connector to retaining
be tested on stop at the bottom. screw back plate
Move it back about 0.5 to 1 mm in
order not to risk a damage of the
connector to be tested. Tighten the
notch
retaining screw of the connector.
distance
0,5 - 1,0 mm

test connector
holder