1 Boiling of The broken of It is toxic if Read lab manual 4 5 20 The awareness of
water thermometer inhaled and easily before do the students to handle
(health, absorbed through experiment thermometer
radioactivity) lungs and
alimentary system
2 titration of Corrosive to Causes of corrosive Use low 4 4 16 Handle the chemical
acid and base metal (safety, to metal when the concentration of with safe distance
chemical) chemical spillage acid and base the at proper place
on it
3 Using Burned socket Causes short circuit Ensure that the 3 4 12 Change with a new
electrical (safety, electrical socket
appliance electrical) installation is
safe
4 Observation Burning the Burns to skin Ensure Bunsen 3 2 6 Wear safety goggle,
of colour of compound of and tubing in wear high
cations cations good working temperature glove
(safety, order and use container
physical)
5 Dropping of the rustic Can cause tetanus Applied another 2 1 2 Replace the metal
high cabinet holder due exposure of layer to the with the new one.
concentration (health, rusted substance rusted part
chemical biological)
6 Sitting on the The painful Causes of Sitting with 2 1 2 Change with a
chair chair (health, backbone injury good position suitable chair at the
ergonomic) and body position laboratory
deviates from
neutral position
Table 7
HIRARC FORM
1. Hazard Identification 2. Risk Analysis 3. Risk Control
No. Task/work Hazard Which can Existing risk Likeli Severity Risk Value Recommended PIC/ (Due
activity cause/effect control hood control measure Date/Status)
1 Boiling of The broken of It is toxic if Read lab manual 4 5 20 The awareness of
water thermometer inhaled and easily before do the students to handle
(health, absorbed through experiment thermometer
radioactivity) lungs and
alimentary system
2 titration of Corrosive to Causes of corrosive Use low 4 4 16 Handle the chemical
acid and base metal (safety, to metal when the concentration of with safe distance
chemical) chemical spillage acid and base the at proper place
on it
3 Using Burned socket Causes short circuit Ensure that the 3 4 12 Change with a new
electrical (safety, electrical socket
appliance electrical) installation is
safe
4 Observation Burning the Burns to skin Ensure Bunsen 3 2 6 Wear safety goggle,
of colour of compound of and tubing in wear high
cations cations (safety, good working temperature glove
physical) order and use container
5 Dropping of the rustic fume Can cause tetanus Applied another 2 1 2 Replace the metal
high hood (health, due exposure of layer to the with the new one.
concentratio biological) rusted substance rusted part
n chemical
6 Sitting on the The painful Causes of Sitting with 2 1 2 Change with a
chair chair (health, backbone injury good position suitable chair at the
ergonomic) and body position laboratory
deviates from
neutral position