Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

LKS FRLP.zm2 - v0.

0 Title

Program information
Author : Author
Project name : Title
Version : 0.0
Module : SR3B261FU
Cycle time in the module : 9 x 2 ms
WATCHDOG action : Inactive
Type of Hardware Input Filtering : Slow (3ms)
Zx keys inactive

Date format : dd/mm/yyyy


Daylight Saving Time change activated
Zone : Europe
Change to Daylight Saving Time : March, Last Sunday
Return to winter time : October, Last Sunday

Author 11/18/2019 1/6


LKS FRLP.zm2 - v0.0 Title

Program diagram
No Contact 1 Contact 2 Contact 3 Contact 4 Contact 5 Coil Comment
I5 I2 I6 q2 iC ± Q1
001

Manual S2 Pb Kiri + LS 1 LS 1 Nc Putar Kiri NO OL + EM Putar Kanan


Q1
002

Putar Kanan
T5
003

M4 m5 m6
004

I5 I1 I9 q1 iC ± Q2
005

Manual S3 Pb Kanan + L... LS 2 Nc Putar Kanan NO OL + EM Putar Kiri


Q2
006

Putar Kiri
T4
007

IB ° M1
008

Out Put S6
M1 ± Q4
009

Past Stop Kontak


± Q5
010

Out Put sensor


I4 TT6
011

Out Put T1
T6 ± Q3
012

Past Pijar Kanan


I3
013

Out Put T2
qA m2 ± Q8
014

Merah Hijau
I7 t1 T2 ± Q9
015

Out Put S4 Kuning


I8 TT1
016

Out Put S5
M2 TT2
017

qA ± M2
018

Merah
T1 TT3
019

M3 q8 ± M3
020

Hijau
t3 ± QA

Author
021
11/18/2019 2/6
Merah
IA ± M4
Out Put S5
M2 TT2
017

LKS FRLP.zm2 - v0.0 qA ± M2


Title
018

Merah
T1 TT3
019

M3 q8 ± M3
020

No Contact 1 Contact 2 Contact 3 Contact 4 Hijau


Contact 5 Coil Comment
t3 ± QA
021

Merah
IA ± M4
022

Otomatis

023

M4 I2 I9 ± M5
024

S2 Pb Kiri + LS 1 LS 2 Nc
M5 TT4
025

I1 I6 TT5
026

S3 Pb Kanan + L... LS 1 Nc
M6 ± M6
027

028

029

030

031

032

033

034

035

036

037

038

039

040

Author
041
11/18/2019 3/6
LKS FRLP.zm2 - v0.0 Title

Physical inputs
No Symbol Function Lock Parameters Location of (L/C) Comment
I1 Discrete inputs --- No parameters (5/2) (26/2) S3 Pb Kanan + LS 2

I2 Discrete inputs --- No parameters (1/2) (24/2) S2 Pb Kiri + LS 1

I3 Discrete inputs --- No parameters (13/2) Out Put T2

I4 Discrete inputs --- No parameters (11/2) Out Put T1

I5 Discrete inputs --- No parameters (1/1) (5/1) Manual

I6 Discrete inputs --- No parameters (1/3) (26/3) LS 1 Nc

I7 Discrete inputs --- No parameters (15/1) Out Put S4

I8 Discrete inputs --- No parameters (16/1) Out Put S5

I9 Discrete inputs --- No parameters (5/3) (24/3) LS 2 Nc

IA Discrete inputs --- No parameters (22/1) Otomatis

IB Discrete inputs --- No parameters (8/1) Out Put S6

IC Discrete inputs --- No parameters (1/5) (5/5) NO OL + EM

Physical outputs
No Symbol Function Latching Location of (L/C) Comment
Discrete
Q1 No (1/6) (2/2) (5/4) Putar Kanan
outputs
Discrete
Q2 No (1/4) (5/6) (6/2) Putar Kiri
outputs
Discrete
Q3 No (12/6) Past Pijar Kanan
outputs
Discrete
Q4 No (9/6) Past Stop Kontak
outputs
Discrete
Q5 No (10/6) Out Put sensor
outputs
Discrete
Q8 No (14/6) (20/5) Hijau
outputs
Discrete
Q9 No (15/6) Kuning
outputs
Discrete
QA No (14/1) (18/5) (21/6) Merah
outputs

Configurable functions
No Symbol Function Lock Latching Parameters Location of (L/C) Comment
M1 Auxiliary relays --- No No parameters (8/6) (9/1)

M2 Auxiliary relays --- No No parameters (14/2) (17/1) (18/6)

M3 Auxiliary relays --- No No parameters (20/1) (20/6)

M4 Auxiliary relays --- No No parameters (4/1) (22/6) (24/1)

M5 Auxiliary relays --- No No parameters (4/2) (24/6) (25/2)

Author 11/18/2019 4/6


LKS FRLP.zm2 - v0.0 Title

No Symbol Function Lock Latching Parameters Location of (L/C) Comment


M6 Auxiliary relays --- No No parameters (4/3) (27/2) (27/6)

T1 Timers No No See details below (15/2) (16/6) (19/1)

T2 Timers No No See details below (15/3) (17/6)

T3 Timers No No See details below (19/6) (21/5)

T4 Timers No No See details below (7/1) (25/6)

T5 Timers No No See details below (3/1) (26/6)

T6 Timers No No See details below (11/6) (12/3)

Timer

T1 Timers
Function A: Active, control held down
Time: 005.0 s

T2 Timers
Function D: Symmetrical flashing
Time: 000.5 s

T3 Timers
Function A: Active, control held down
Time: 010.0 s

Author 11/18/2019 5/6


LKS FRLP.zm2 - v0.0 Title

T4 Timers
Function A: Active, control held down
Time: 002.0 s

T5 Timers
Function A: Active, control held down
Time: 002.0 s

T6 Timers
Function D: Symmetrical flashing
Time: 000.5 s

Author 11/18/2019 6/6

You might also like