Digital Pressure Sensor


DP-101(A) / 102(A) SERIES Ver. 2

Conforming to Certification
Recognition
EMC Directive [DP-101(A)/102(A) only]

Pressure Sensor Evolutions


To Come

2013.11 panasonic.net/id/pidsx/global
Achieved further efficiency with
4 upgrades, keeping the same
operability
Note: The upgrade will be implemented from production in October 2013, based on stock status.

Upgrade 1
Superior visibility
Improved visibility in Digital Display
Improvements to the digital display deliver a wide viewing
angle along with increased clarity. The display pressure
range and set pressure range have also been increased.
Old DP-100 series New DP-100 series

Upgrade 2
Long-distance transmission of analog output
Addition of analog current output capability to multifunctional models
Users can now select either voltage output or current output as analog output according to their
application.

Upgrade 3
Reduced environmental impact 14 % lower
after update
14% lower power consumption
(during normal operation)
Thanks to a redesign of its circuitry, power consumption of
Old DP-100 series New DP-100 series
the low-power-consumption DP-100 series during normal 840 mW (normal operation) 720 mW (normal operation)
operation has been reduced by 14%. The display is shut
off entirely during ECO / FULL mode operation for power Up to 50
% lower
in ECO mode
savings of up to 50% compared to normal operation, and
display brightness is lowered during ECO / STD mode
operation for power savings of up to 30% compared to Normal operation ECO / FULL operation
720 mW 360 mW
normal operation.

Upgrade 4
Enhanced power circuitry
Addition of a reverse polarity protection circuit to the
transistor output circuit
To prevent from breakage due to miswiring.

1
Dual Display
A new global standard Direct setting

“Current value” and “threshold value”


can be checked at the same time!
Current value

Threshold value

ect setting
Dir

Works like a dial


Main display
control type sensor
Comparative Output 1 operation indicator
Sub display
Comparative Output 2 operation indicator
Work as analog voltage output operation
indicator in Multi-function type

Mode selection key Decrement key


Increment key

Dual display allows direct Previous model with single display

setting of threshold value


Equipped with a 30 mm 1.181 in square
Threshold value setting method

compact-sized dual display. The current


value and the threshold value can be
-91.8
checked at the same time, so the
threshold value can be set and checked
smoothly without switcing to another Take a note on current value Operate MODE key Adjust threshold value Return to RUN operation
screen mode. ON / OFF operations still
continue while the threshold values are
being set, so setting to the same DP-100 with dual display
sensitivity as dial control-type sensors is
possible. Key lock function is equipped
as well.
Simply press a button Man-hours reduced by 3/
during RUN operation
4

3-color display (Red, Green, Orange) Readable digital display!


The main display changes color in line with changes in the Alphanumeric indication in 12 segments is used. This improved
status of output ON / OFF operation, and it also changes color visual checking.
while setting is in progress. The sensor status can therefore be
understood easily, and operating errors can be reduced.

OFF: Green (or Red) ON: Red (or Green) SET: Orange
Main
Display

During normal operation During setting

2
Copy function helps operation to be accurate and quick

Copy function reduces man-hours and human error


Sensors can be connected to a master sensor one by one, and a copy of the setting details for the master sensor can be transmitted as data
to other sensors. If making the same settings for multiple sensors, this prevents setting errors among other sensors and in addition, when
machinery design are changed, there would be less change in work orders.

Setting details can be copied.

Copying via wiring Master sensor


Power supply
Slave sensor

+V +V

0V 0V
Comparative Comparative
output 1 output 1
Comparative Comparative
output 2 output 2

Details transmitted

Details received

Detail
s cop
ied

Note: Settings cannot be copied from the new version (Ver. 2) to the old version.
However, settings can be copied from the old version to the new version (Ver. 2).

Advantage
1 Setting man-hours are reduced and sensor setting time is shortened.

Number of pressure sensor: 1 unit per 1 equipment, 4 equipment per 1 line


4th equipment:
5 minutes
approx.

Reduction
3rd equipment:
5 minutes of lead time
approx.

The setting details for the master sensor are


2nd equipment:
5 minutes retained, so continuous copying is possible.
approx. 20 seconds
4th equipment:
3rd equipment:
For 2nd and subsequent lines, the data
approx. 2nd equipment: transmission time only is required.
1st equipment:

5 minutes Master 5 minutes


1st equipment:
approx. sensor approx. 4th equipment:
20 seconds 3rd equipment:
approx. 2nd equipment:
1st equipment:
Sensor setting time: Sensor setting time: Sensor setting time:
20 minutes approx. 5 minutes 20 seconds approx. 20 seconds approx.
Previously DP-100, 1st line DP-100, 2nd line

Advantage
2 Human operating error is reduced.
‡ Because all details are copied automatically, problems as a result of human error can be
prevented.
‡ Instruction manuals can be updated easily when changes are made to equipment design.

3
Setting is smooth and easy

The sensor’s setting operation mode has a 3-level


configuration to suit the frequency of use.
The setting levels are clearly separated into “RUN mode” for operation RUN mode
settings that are carried out daily, “MENU SETTING mode” for basic settings,
and “PRO mode” for special and detailed setting. These make setting Settings such as threshold value
operations easy to understand and easy to carry out. adjustment and key lock operation
can be carried out while the
sensor is operating.

Simple setting RUN mode

MENU SETTING mode


MENU SETTING mode
Basic settings such as output
mode setting and NO / NC
Special and PRO mode switching can be carried out.
detailed setting

PRO mode

High-level function settings such


as hysteresis adjustment and the
copy function can be carried out.

Displayed in orange while setting is in progress


The display appears in red and green during RUN operation, but it changes to orange while setting is in progress, so that the sensor status
can be viewed at a glance.

RUN operation RUN mode While setting MENU SETTING mode PRO mode

or

Red or green when output is ON / OFF Orange while setting is in progress

Default settings that can be used straight away Buttons with good clicking touch
Easy-to-use default settings are provided for applications that are The buttons have a good clicking touch,
used frequently by pressure sensors. The default settings for low allowing smooth setting.
pressure types are ideal for suction confirmation applications, and
those for high pressure types are ideal for checking reference
pressure.

Low pressure type High pressure type


The clicking feeling is
Comparative output 1 Comparative output 1
Hysterisys 3digits Ideal for Hysterisys 3digits
transmitted even through gloves.
ON checking
suction
Ideal for
checking
OFF reference
pressure
Reset function
–100 kPa –50 kPa 0 kPa 0 MPa 0.5 MPa 1 MPa
If a problem ever occurs with the sensor settings, they can be reset
to the default settings.

4
Full range of performance and functions in a compact body

All lineup models are compound pressure High performance accomplished Low pressure type
types The low pressure type displays measurements in 0.1 kPa at a
No sensor settings are required to switch between positive pressure resolution of 1/2,000 and has a response time of 2.5 ms (variable up
and negative pressure, so that the number of registered part to 5,000 ms), ±0.5 % F.S. temperature characteristics and ±0.1 %
numbers can be decreased. F.S. repeatability, achieving high detection performance.

<For low pressure>


Ideal for applications such
as suction. No mis- Resolution: 1/2,000
operations due to vacuum <For high pressure>
breakdown occur. Ideal for applications such
Response time: 2.5 ms
as checking reference Temperature characteristics: ±0.5 % F.S.
– 100 kPa 0 kPa 100 kPa pressure. Can also be used
For low for simple suction.
Repeatability: ±0.1 % F.S.
pressure DP-101Ƒ
1 MPa
Displays measurements in 0.1 kPa
For high
pressure DP-102Ƒ

Equipped with independent dual output Standard type Three output modes are suitable for a wide
Equipped with two independent comparative outputs, and separate range of applications
sensing modes can be selected for each of them. Since there are
two comparative outputs, one of the comparative outputs can even
be used for alarm output. In addition, output, which is not being
1 EASY mode
used, can be disabled. This mode is used for comparative output ON / OFF control.

Ɣ Vacuum breakdown can also be notified during H (Hysteresis)


Pressure

suction applications! P

0
ON ON
Comparative output 1 Comparative output H: Fixed
OFF
EASY mode Suction checking
OFF Notes: 1) Hysteresis can be fixed to one of eight different levels.
2) “ ” appears in the sub display for comparative output 1,
and “ ” appears for comparative output 2.
ON
Comparative output 2
EASY mode
2 Hysteresis mode
OFF
Vacuum breakdown checking This mode is used for setting comparative output hysteresis to
the desired level and for carrying out ON / OFF control.
– 100 kPa P-1 0 kPa P-2
Pressure

Hi
H (Hysteresis)
Lo
Ɣ Reference pressure alarm output is possible during 0
reference pressure checking! Comparative output
ON
H: 1 digit or more
OFF

Comparative output 1 ON Reference Note: “ ” or “ ” appears in the sub display for comparative
Hysteresis pressure output 1, and “ ” or “ ” appears for comparative output 2.
mode checking
OFF

3 Window comparator mode


Alarm output This mode is used for setting comparative output ON and OFF
ON
Comparative output 2 at pressures within the setting range.
EASY mode
OFF H (Hysteresis)
Pressure

Hi
H (Hysteresis)
0 kPa Lo-1 Hi-1 P-2
Lo
0
ON
Comparative output H: Fixed
OFF

Notes: 1) Hysteresis can be fixed to one of eight different levels.


2) “ ” or “ ” appears in the sub display for comparative
output 1, and “ ” or “ ” appears for comparative output 2.

5
Equipped with auto-reference / remote zero-adjustment functions,
More precise pressure management is achieved with a minimum of effort Multi-function type
If the reference pressure of the
device changes, two functions Without auto-reference and remote zero-adjustment functions
are selectable. One is Comparative output: Window comparator mode
auto-reference function, which Hi-1 ‡ ‡ ‡ 30, Lo-1 ‡ ‡ ‡ 25
partially shift the comparative Fixed set value
output judgment level by the
amount that the reference 40
pressure shifts. The other is NG?
remote zero-adjustment 30
function, which can reset the Leak threshold level
OK
display value to zero via 25
external input. These functions 20
are ideal for places where the NG?
reference pressure fluctuates 15
wildly, or where fine settings are Variation in the filling pressure
Trial 1
required. Trial 2
Trial 3
Pressure
0 Time
Because the threshold level is fixed for conventional pressure sensors,
changes in the reference pressure result in wrong decisions.

With auto-reference function applied With remote zero-adjustment function applied


Comparative output: Window comparator mode Comparative output: Window comparator mode
Hi-1 ‡ ‡ ‡ 0, Lo-1 ‡ ‡ ‡ – 5 Hi-1 ‡ ‡ ‡ 0, Lo-1 ‡ ‡ ‡ – 5
Sets the absolute threshold level Sets the absolute threshold level
Auto-reference input Remote zero-adjustment input
The display remains at “30” and The display is forced to “0”, and only the
only the threshold level is changed. filling pressure drop range is displayed.

30 30
0
25 OK 25 –5 OK
20 20
Threshold level after applying Threshold level after applying
15 auto-reference input remote zero-adjustment input
15
Threshold level before applying Threshold level before applying
auto-reference input remote zero-adjustment input
Trial 1 Trial 1
Pressure 0 Pressure 0
Displayed when remote zero-
–5 Auto-reference input value‡ ‡ ‡ –5 adjustment input is applied‡ ‡ ‡
Time Time

When auto-reference input is applied, the reference pressure “30” is When remote zero-adjustment input is applied, the reference pressure is forced to “0”.
added to the threshold level. If the reference pressure changes to “20” or If the reference pressure changes to “20” or “40”, the remote zero-adjustment input
“40”, the auto-reference input compensates for this every time by changing adjusts the reference pressure to “0” every time the reference pressure changes, so
the threshold level, so any variation in the filling pressure can be ignored. any variation in the filling pressure can be ignored.

Peak hold and Bottom hold functions Energy-saving design! Equipped with an ECO mode
The peak values and bottom values for fluctuating pressures can be This mode lowers the display luminance to cut power consumption
displayed using the dual display. by approximately 30 %. The displays can also be turned off
completely to achieve a power saving of approximately 40 %.
Power consumption Power consumption
Approx. Approx.
Normal ECO-STD 30 % less ECO-FULL 40 % less

Blinks alternately

Current consumption for Current consumption for Current consumption for


24 V power supply: 35 mA or less 24 V power supply: 25 mA or less 24 V power supply: 20 mA or less

6
Other useful functions

Sub display can be customized Setting details can be recognized at a glance


The sub display can be set to indicate any other desired values or The DP-100 setting details appear in the digital display. Because
letters apart from the threshold value. This eliminates the need for the settings are in numeric form that can be easily understood, it is
tasks such as affixing a label to the device to indicate the normal useful such as when receiving technical support by telephone.
pressure value.

What are the check The code on the main display is 3205.
codes for the setting? The sub display shows 7011.

2nd digit: Setting status for


comparative output 2 3rd digit: Threshold value setting
1st digit: Setting status for 4th digit: Display color setting
comparative output 1

Indicates desired values and letters

5th digit: Response time


setting 8th digit: ECO mode setting
<Unit display> <Number display> <Desired letter display> 6th digit: Display unit setting 7th digit: Display refresh rate setting

Cable can be connected with one-touch


Connector attached cable (2m 6.562 ft), as an accessory, can be Ɣ Types without connector attached DP-10Ƒ-J
connected easily with one-touch connection. cable are also available
Commercially-available connectors can be used for cable
connections. Cables in required length can be used, so this
contributes to reduction in waste of unwanted cables.

Environmentally
friendly
Commercially-available
Connection cable * parts can be used!

* Options: 1 m 3.281 ft / 3 m 9.843 ft / 5 m 16.404 ft


types are also available.

Ɣ M8 plug-in connector types are also available (Only for Europe) DP-11Ƒ-E-P-J

M8 connector
Mating cable
CN-24A-C2 (cable length 2 m 6.562 ft)
CN-24A-C5 (cable length 5 m 16.404 ft)

G 1/8 male thread


M5 female thread

7
Installation is also easy!

Tight installation to panels is possible


An exclusive mounting bracket that is suitable for 1 to 6 mm 0.039
to 0.236 in panel thickness is available.

Neat and
Front protection
space cover available
Tight installation is possible saving MS-DP1-3

A single mounting hole!

Ɣ An exclusive mounting bracket that supports tight installation is available


Space savings can also be achieved even when an L-shaped mounting bracket is used.
Tight installation is possible
‡ MS-DP1-1 ‡ MS-DP1-5

Positioning bosses for easier


Ceiling mounting Floor mounting Rear mounting
mounting bracket installation

Short pressure port type is lightweight and takes up little space


Space saving! Light weight of 30 g! *
Compact size with a depth of only 30 mm 1.181 in, so that it can 10 g lighter than standard types. This reduces the loads on movable
easily fit into narrow spaces. parts such as robot arms.
Short pressure
port type DP-10Ƒ-M
Standard type M5 female thread+R1 8 male thread

Elbow joint

* Excluding cables with connector attached

Short pressure port type

Shortened to Ideal for clean environments!


12.5 mm 0.492 in ! Stainless steel (SUS303) which does not rust or generate gas is
Light weight used as the port material.
30g approx.

30 mm M5 female thread [Material: Stainless steel (SUS)]


1.181 in
* The illustration shows connection using an elbow joint. The elbow joint is sold separately.

8
DP-100

Flat installation on the wall by shifting the direction Rc1/8 conversion bushing is available. Compatible
of the pressure port For short pressure port type with previous model For short pressure port type
By mounting the flat attachment By equipping the push-in converter with DP-10Ƒ-M(-P), pressure
Previous model DP2 / DP3
to DP-10Ƒ-M(-P), pressure port series can be switched over to port can be converted from M5 female thread to Rc1/8 female thread.
and cable can now be pulled out DP-100 series. Bore diameter conversion to the DP2 / DP3 series is possible.
in downward, left or right
Previous model
directions. Flat mounting on M5 female thread Rc1/8 female thread
surfaces such as the wall is
made possible.

Flat attachment
06'3)Ƒ 20 mm 20 mm
0.787 in pitch 0.787 in pitch

Conversion bushing
Model No. Pressure port
MS-DP1-7
MS-DP1-FM M5 female thread
MS-DP1-FR Rc1/8 female thread
MS-DP1-FN NPT1/8 female thread
MS-DP1-FE G1/8 female thread

3 possible directions to mount

ORDER GUIDE

Type Appearance Rated pressure range Model No. Pressure port Comparative output

For low pressure í100.0 to +100.0 NPa DP-101


Standard M5 female thread
For high pressure í0.100 to +1.000 MPa DP-102 +
Asia

NPN open-collector transistor


For low pressure í100.0 to +100.0 NPa DP-101A R 1/8
Multi-function male thread
For high pressure í0.100 to +1.000 MPa DP-102A
For low pressure í100.0 to +100.0 NPa DP-101-E-P
Standard M5 female thread
For high pressure í0.100 to +1.000 MPa DP-102-E-P +
PNP open-collector transistor
For low pressure í100.0 to +100.0 NPa DP-101A-E-P G 1/8
Standard pressure port type

Multi-function male thread


Europe

For high pressure í0.100 to +1.000 MPa DP-102A-E-P


M8 plug-in connector type

For low pressure í100.0 to +100.0 NPa DP-111-E-P-J


Standard M5 female thread
For high pressure í0.100 to +1.000 MPa DP-112-E-P-J +
PNP open-collector transistor
For low pressure í100.0 to +100.0 NPa DP-111A-E-P-J G 1/8
Multi-function male thread
For high pressure í0.100 to +1.000 MPa DP-112A-E-P-J
DP-101-N NPN open-collector transistor
For low pressure í100.0 to +100.0 NPa
DP-101-N-P PNP open-collector transistor
Standard
DP-102-N NPN open-collector transistor
North America

For high pressure í0.100 to +1.000 MPa M5 female thread


* CN-14A-C2 DP-102-N-P PNP open-collector transistor
+
(Connector attached
cable 2 m 6.562 ft ) DP-101A-N NPT 1/8 NPN open-collector transistor
For low pressure is attached. í100.0 to +100.0 NPa male thread
DP-101A-N-P PNP open-collector transistor
Multi-function (Excluding M8 plug-in
connector type ) DP-102A-N NPN open-collector transistor
For high pressure í0.100 to +1.000 MPa
DP-102A-N-P PNP open-collector transistor
DP-101-M NPN open-collector transistor
For low pressure í100.0 to +100.0 NPa
Short pressure port type

DP-101-M-P PNP open-collector transistor


Standard
DP-102-M NPN open-collector transistor
For high pressure í0.100 to +1.000 MPa
DP-102-M-P PNP open-collector transistor
Asia

M5 female thread
DP-101A-M NPN open-collector transistor
For low pressure í100.0 to +100.0 NPa
DP-101A-M-P PNP open-collector transistor
Multi-function
DP-102A-M NPN open-collector transistor
For high pressure í0.100 to +1.000 MPa
DP-102A-M-P PNP open-collector transistor

Type without connector attached cable


Type without connector attached cable CN-14A-C2 is available. When ordering this type, suffix “-J” to the end of Model No.
(e.g.) Type without connector attached cable of DP-101-N is “DP-101-N-J”

Accessory
‡CN-14A-C2
(Connector attached cable 2 m 6.562 ft)

9
DP-100

OPTIONS

Connector attached cable


Designation Model No. Description ‡&1$&Ƒ
‡&1$5&Ƒ
CN-14A-C1 Length: 1 m 3.281 ft
0.2 mm2 4-core cabtyre cable with
Connector CN-14A-C2 (Note) Length: 2 m 6.562 ft
attached cable connector on one end
CN-14A-C3 Length: 3 m 9.843 ft Cable outer diameter: ø3.7 mm ø0.146 in
CN-14A-C5 Length: 5 m 16.404 ft
CN-14A-R-C1 Length: 1 m 3.281 ft
Connector Length: 2 m 6.562 ft 0.2 mm2 4-core flexible cabtyre cable
CN-14A-R-C2
attached cable with connector on one end
(Flexible cable) CN-14A-R-C3 Length: 3 m 9.843 ft Cable outer diameter: ø3.7 mm ø0.146 in
CN-14A-R-C5 Length: 5 m 16.404 ft
CN-24A-C2 Length: 2 m 6.562 ft For M8 plug-in connector type
M8 connector
The connector on one end M8 connector attached cable
attached cable
CN-24A-C5 Length: 5 m 16.404 ft Cable outer diameter: ø4 mm ø0.157 in
‡&1$&Ƒ
Connector CN-14A Set of 10 housings and 40 contacts
Allows sensors to be installed on the flooring or ceiling.
Sensor MS-DP1-1 Multiple sensors can also be mounted closely.
mounting
bracNet Allows sensors to be installed on the wall. Multiple sensors
MS-DP1-5 can also be mounted closely.
Allows installation to panels with thicNness of 1 to 6 mm 0.039
MS-DP1-2 to 0.236 in. Multiple sensors can also be mounted closely.
Panel mounting
bracNet Allows replacement from DP2 / DP3 series to DP-100 series. For newly designed
MS-DP1-4 set-up, please use panel mounting bracNet MS-DP1-2 for panel mounting. 31.4 ø4
1.236 ø0.157
Front protection Protects the adjustment surfaces of sensors.
cover MS-DP1-3 (Can be attached when using the panel mounting bracNet)
ø9
Conversion By equipping with DP-10Ƒ-M(-P), pressure port can be converted to ø0.354 (Unit: mm in)
bushing
MS-DP1-7 Rc1/8 female thread. Replacement from DP2 / DP3 series is possible.
MS-DP1-FM M5 female thread
Pressure port and cable can now be
Flat MS-DP1-FR Rc1/8 female thread pulled out in downward, left or right Sensor mounting bracket
attachment MS-DP1-FN NPT1/8 female thread directions. Flat mounting on surfaces ‡MS-DP1-1
such as the wall is made possible.
MS-DP1-FE G1/8 female thread
M3 (length 6 mm 0.236 in)
Note: The connector attached cable CN-14A-C2 is supplied with the DP-100 series. screws with washers
(Excluding M8 plug-in connector type). (Accessory for
MS-DP1-1 )
Sensor mounting
Panel mounting bracket, Front protection cover bracNet
‡MS-DP1-2 ‡MS-DP1-4 DP2 / DP3
MS-DP1-1
‡MS-DP1-3
Front protection cover
DP
2-2
0

ñ101
.3kP
a

DPX-04 (optional) Remove


OUT
1

OUT
0-AD 2
J
MOD
E

can be installed on
MS-DP1-4.
Front protection cover Remove
MS-DP1-3
‡MS-DP1-5
Insert M3 (length 6 mm 0.236 in)
DP-100 Mounting holes screws with washers
for DP2 / DP3 series
can be used as is. (Accessory for
MS-DP1-5 )
Panel mounting bracNet Panel mounting bracNet MS-DP1-4
MS-DP1-2
Sensor mounting
bracNet
Flat attachment MS-DP1-5
‡MS-DP1-FM ‡MS-DP1-FR
‡MS-DP1-FN
‡MS-DP1-FE

Net weight: MS-DP1-FM 15g approx. Conversion bushing


MS-DP1-FR/FN/FE 25g approx. ‡MS-DP1-7
Two M3 (length 8 mm 0.315 in) screws,
M5 female Rc1/8 female
two M4 (length 20 mm 0.787 in) screws are attached. thread thread
Recommended connector
Contact: SPHD-001T-P0.5, Housing: PAP-04V-S
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.

Recommended crimping tool Conversion bushing


MS-DP1-7
Model No.: YC-610R
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.

10
DP-100

SPECIFICATIONS

Standard Multi-function
Type
For low pressure For high pressure For low pressure For high pressure
Asia (Note 2) DP-101(-M)(-P) DP-102(-M)(-P) DP-101A(-M)(-P) DP-102A(-M)(-P)
Model No.

Europe DP-101-E-P DP-102-E-P DP-101A-E-P DP-102A-E-P


M8 plug-in connector type DP-111-E-P-J DP-112-E-P-J DP-111A-E-P-J DP-112A-E-P-J
Item North America (Note 2) DP-101-N(-P) DP-102-N(-P) DP-101A-N(-P) DP-102A-N(-P)
Type of pressure Gauge pressure
Rated pressure range í100.0 to +100.0 kPa í0.100 to +1.000 MPa í100.0 to +100.0 kPa í0.100 to +1.000 MPa
í101.0 to +101.0 kPa í0.101 to +1.010 MPa í101.0 to +101.0 kPa í0.101 to +1.010 MPa
í1.030 to +1.030 kgf/cm2 í101 to +1,010 kPa í1.030 to +1.030 kgf/cm2 í101 to +1,010 kPa
í1.010 to +1.010 bar í1.03 to +10.30 kgf/cm2 í1.010 to +1.010 bar í1.03 to +10.30 kgf/cm2
Set pressure range
í14.64 to +14.64 psi í1.01 to +10.10 bar í14.64 to +14.64 psi í1.01 to +10.10 bar
í757 to +757 mmHg í757 to +757 mmHg
í29.8 to 29.8 inHg í14.6 to +146.4 psi í29.8 to 29.8 inHg í14.6 to +146.4 psi

Pressure withstandability 500 kPa 1.5 MPa 500 kPa 1.5 MPa
Applicable fluid Non-corrosive gas
Selectable unit For low pressure: kPa, kgf/cm2, bar, psi, mmHg, inHg, For high pressure: MPa, kPa, kgf/cm2, bar, psi
Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less
Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
Power consumption ECO mode: 480 mW or less at STD (Current consumption 20 mA or less at 24 V supply voltage)
360 mW or less at FULL (Current consumption 15 mA or less at 24 V supply voltage)
<Asia (NPN output), North America (NPN output)> <Asia (PNP output), Europe, North America (PNP output)>
NPN open-collector transistor PNP open-collector transistor
Comparative output ‡ Ma[imum sink current: 100 mA ‡ Ma[imum source current: 100 mA
‡ Applied voltage: 30 V DC or less (between comparative output and 0 V) ‡ Applied voltage: 30 V DC or less (between comparative output and +V)
‡ Residual voltage: 2 V or less (at 100 mA sink current) ‡ Residual voltage: 2 V or less (at 100 mA source current)
Output operation / Output modes NO / NC (selectable by key operation) / EASY mode / Hysteresis mode / Window comparator mode
Hysteresis Minimum 1 digit (variable) (however, 2 digits when using psi unit)
Repeatability ±0.1 % F.S. (within ±2 digits) ±0.2 % F.S. (within ±2 digits) ±0.1 % F.S. (within ±2 digits) ±0.2 % F.S. (within ±2 digits)
Response time 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Short-circuit protection Incorporated
<Asia (NPN output), North America (NPN output)> <Asia (PNP output), Europe, North America (PNP output)>
E[ternal input (Note 3)
ON voltage: 0.4 V DC or less ON voltage: 5 V to +V DC
Auto-reference function /
OFF voltage: 5 to 30 V DC, or open OFF voltage: 0.6 V DC or less, or open
Remote zero-adjustment
,nput impeGance: 0 Nȍ appro[. Input impeGance: 10 Nȍ appro[.
function
Input time: 1 ms or more Input time: 1 ms or more
Output voltage: 1 to 5 V DC Output voltage: 0.6 to 5 V
Zero point: within 3 V ±5 % F.S. Zero point: within 1 V ±5 % F.S.
Analog voltage output (Note 3) Span: within 4 V ±5 % F.S. Span: within 4.4 V ±5 % F.S.
Linearity: within ±1 % F.S. Linearity: within ±1 % F.S.
Output impeGance: 1 Nȍ appro[. Output impeGance: 1 Nȍ appro[.
Output current: 4 to 20 mA Output current: 2.4 to 20 mA
Zero point: 12 mA ±5 % F.S. Zero point: 4 mA ±5 % F.S.
Analog current output (Note 3) Span: 16 mA ±5 % F.S. Span: 17.6 mA ±5 % F.S.
Linearity: within ±1 % F.S. Linearity: within ±1 % F.S.
LoaG resistance: 250 ȍ (ma[.) LoaG resistance: 250 ȍ (ma[.)
Display 4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
í101.0 to +101.0 kPa í0.101 to +1.010 MPa í101.0 to +101.0 kPa í0.101 to +1.010 MPa
í1.030 to +1.030 kgf/cm2 í101 to +1,010 kPa í1.030 to +1.030 kgf/cm2 í101 to +1,010 kPa
í1.010 to +1.010 bar í1.03 to +10.30 kgf/cm2 í1.010 to +1.010 bar í1.03 to +10.30 kgf/cm2
Displayable pressure range í14.64 to +14.64 psi í14.64 to +14.64 psi
í1.01 to +10.10 bar í1.01 to +10.10 bar
í757 to +757 mmHg í757 to +757 mmHg
í29.8 to 29.8 inHg í14.6 to +146.4 psi í29.8 to 29.8 inHg í14.6 to +146.4 psi
Orange LED Orange LED
Indicator
( Comparative output 1 operation indicator, comparative output 2 operation indicator:
Lights up when each comparative output is ON )( Comparative output 1 operation indicator: Lights up when comparative output is ON,
Analog voltage output operation indicator: Lights up when setting )
Protection IP40 (IEC)
Environmental resistance

Ambient temperature í10 to +50 °C +14 to +122 °F, Storage: í10 to +60 °C +14 to +140 °F
Ambient humidity 35 to 85 % RH (No dew condensation or icing allowed), Storage: 35 to 85 % RH
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50Mȍ or more with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 500 Hz frequency, 3 mm 0.118 in amplitude, in X, Y and Z directions for two hours each (when panel is mounted: 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude, in X, Y and Z directions for two hours each)
Shock resistance 100 m/s2 acceleration (10 G appro[.) in X, Y and Z directions for three times each
Temperature characteristics Within ±0.5 % F.S. (at +20 °C +68 °F) Within ±1 % F.S. (at +20 °C +68 °F) Within ±0.5 % F.S. (at +20 °C +68 °F) Within ±1 % F.S. (at +20 °C +68 °F)
Pressure port Asia: M5 female thread + R (PT) 1/8 male thread >e[cluding DP-Ƒ-M(-P)], Europe: M5 female thread + G 1/8 male thread, North America: M5 female thread + NPT 1/8 male thread
Material Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS303) , Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber
Connecting method / Cable length Connector / Total length up to 100 m 328.084 ft (less than 30 m 98.425 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable
Weight Net weight: 40 g appro[. (DP-10Ƒ-M(-P): 30 g appro[.), Gross weight: 135 g appro[. (DP-10Ƒ-M(-P):125 g appro[.)
Accessories CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1pc. (e[cluding M8 plug-in connector type)
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) Model Nos. of Asia type having “-M´ are short pressure port type. Model Nos. of Asia and North America types having the suffi[ “-P” are PNP output type.
3) Cannot be used at the same time.
11
DP-100

I/O CIRCUIT AND WIRING DIAGRAMS

DP-10Ƒ NPN output type


Terminal No.
I/O circuit diagram Terminal No. Multi-function type Color code of connector attached cable

Standard type Color code of connector attached cable


1
(Brown) +V
(Brown) +V 5V D1
1 D3
D1 (White) Analog output
(Black) Tr1

Sensor circuit
3
D2 Load or E[ternal input Load
Comparative output 1 + 12 to 24 V DC
Sensor circuit

Tr1 2
Load 1kȍ D2 (Black) Comparative output 1
100 mA ma[. + í ±10 %
12 to 24 V DC Tr2 2
ZD1 D3 (White) Comparative output 2 ±10 %
Tr2 3 í 100 mA ma[.
ZD1
100 mA ma[. (Blue) 0 V
ZD2 4
(Blue) 0 V
4 Internal circuit Users’ circuit
Internal circuit Users’ circuit
Symbols ‡ ‡ ‡ D1, D2 : Reverse supply polarity protection diode
Symbols ‡ ‡ ‡ D : Reverse supply polarity protection diode ZD1 : Surge absorption zener diode
ZD1, ZD2 : Surge absorption zener diode Tr1 : PNP input transistor
Tr1, Tr2 : NPN output transistor Tr2 : NPN output transistor

Terminal arrangement diagram


Terminal Designation
1 +V
2 Comparative output 1
Standard type: Comparative output 2
3
1 2 3 4 Multi-function type: Analog output or E[ternal input
4 0V

DP-10Ƒ-P PNP output type


Terminal No.
I/O circuit diagram Terminal No. Multi-function type Color code of connector attached cable

Standard type Color code of connector attached cable


1
(Brown) +V
(Brown) +V D1
1
ZD1
D Tr1 100 mA ma[.
Sensor circuit

ZD1 2 +
100 mA ma[.
Sensor circuit

(Black) Comparative output 1 12 to 24 V DC


Tr1 1kȍ D3 ±10 %
2 + 12 to 24 V DC í
ZD2 (Black) Comparative output 1
Tr2 (White) Analog output Load
100 mA ma[. í ±10 % 3
D2 or E[ternal input
Tr2 3
Load
(White) Comparative output 2 (Blue) 0 V
Load 4
(Blue) 0 V
4 Internal circuit Users’ circuit
Internal circuit Users’ circuit
Symbols ‡ ‡ ‡ D1, D2 : Reverse supply polarity protection diode
Symbols ‡ ‡ ‡ D : Reverse supply polarity protection diode ZD1: Surge absorption zener diode
ZD1, ZD2 : Surge absorption zener diode Tr1 : PNP output transistor
Tr1, Tr2 : PNP output transistor Tr2 : NPN input transistor

Terminal arrangement diagram


Terminal Designation
1 +V
2 Comparative output 1
Standard type: Comparative output 2
3
1 2 3 4 Multi-function type: Analog output or E[ternal input
4 0V

12
DP-100

I/O CIRCUIT AND WIRING DIAGRAMS

'3Ƒ(3- PNP output type


Terminal No.
I/O circuit diagram Terminal No. Multi-function type Color code of connection cable
Standard type Color code of connection cable (Brown) +V
1
(Brown) +V D1
1
ZD1
D

Sensor circuit
Tr1 100 mA max.
ZD1 4 +
Sensor circuit

100 mA max. 1k (Black) Comparative output 1 12 to 24 V DC


Tr1 4 + í ±10 %
ZD2 (Black) Comparative output 1 12 to 24 V DC
Tr2 (White) Analog voltage output Load
100 mA max. í ±10 % 2
D2 or External input
Tr2 2
Load
(White) Comparative output 2 (Blue) 0 V
Load 3
(Blue) 0 V
3 Internal circuit Users’ circuit
Internal circuit Users’ circuit Symbols ‡ ‡ ‡ D1, D2 : Reverse supply polarity protection diode
ZD1: Surge absorption zener diode
Symbols ‡ ‡ ‡ D : Reverse supply polarity protection diode
Tr1 : PNP output transistor
ZD1, ZD2 : Surge absorption zener diode
Tr2 : NPN input transistor
Tr1, Tr2 : PNP output transistor

Terminal arrangement diagram


1
2 Terminal Designation
1 +V
4
Standard type: Comparative output 2
3 2
Multi-function type: Analog output or External input
3 0V
4 Comparative output 1

PRECAUTIONS FOR PROPER USE

‡Never use this product as a sensing device for Mounting


personnel protection. ‡MS-DP1-1/MS-DP1-5 sensor mounting brackets are available
‡In case of using sensing devices for personnel separately, and it should be used for mounting. When tightening
protection, use products which meet laws and standards, the sensor to the sensor mounting bracket, use a tightening torque
such as OSHA, ANSI or IEC etc., for personnel of 0.5 N·m or less.
protection applicable in each region or country. M3 (length 6 mm 0.236 in)
‡The DP-100 series is designed for use with non-corrosive screws with washers
gas. It cannot be used with liquid or corrosive gas. Accessory for MS-DP1-1
(
and MS-DP1-5 )
Wiring
‡Make sure that the power supply is off while wiring.
Sensor mounting bracket
‡Verify that the supply voltage variation is within the rating. MS-DP1-1 (Optional)
‡If power is supplied from a commercial switching regulator, ensure
that the frame ground (F.G.) terminal of the power supply is
connected to an actual ground.
‡In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this sensor, connect the frame ‡The MS-DP1-2 panel mounting bracket (optional) and the MS-DP1-3
ground (F.G.) terminal of the equipment to an actual ground. front protection cover (optional) are also available.
‡Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
‡Incorrect wiring will cause problems with operation.
Connection Connector
attached cable
‡Do not apply stress directly to the [CN-14A(-R)-CƑ] Front protection cover
MS-DP1-3 (optional)
connection cable leader or to the
connector.

Conditions in use for CE conformity


Panel mounting bracket
‡The DP-100 series is a CE conformity product complying with
MS-DP1-2 (optional)
EMC Directive. The harmonized standard with regard to immunity
that applies to this product is EN 61000-6-2 and the following
condition must be met to conform to that standard.

Condition
‡The line to connect with this sensor should be less than
30 m 98.425 ft.

13
DP-100

PRECAUTIONS FOR PROPER USE

Mounting Piping
‡The MS-DP1-4 panel mounting bracket is available when ‡If connecting a commercially-available 12 mm 0.472 in
spanner
switching from the DP2 / DP3 series. coupling to the pressure port, attach a
DP2 / DP3 12 mm 0.472 in spanner (14 mm 0.551 in
DP
2-2
0

ñ10
1.3k
Pa
spanner for DP-100-E type) to the hexagonal
Front protective cover OUT
1

$'
-
OUT

MO
2

DE Remove section of the pressure port to secure it, and


DPX-04 (Optional) tighten at a torque of 9.8 N·m or less. If it is
can be installed on
MS-DP1-4. tightened using excessive torque, it may
Remove damage the coupling or the pressure port.
In addition, wrap sealing tape around the
coupling when connecting it to prevent leaks.
Insert ‡If connecting a commercially-available joint to the pressure port of
DP-100
Mounting holes the DP-10Ƒ-M, hold the main unit in your hand to steady it, and
for DP2 / DP3 series tighten to a torque of 1.0 N·m or less. If it is tightened to an
can be used as is.
excessive torque, the joint or the main unit may become
Panel mounting bracket MS-DP1-4 damaged.
‡If connecting a commercially-available joint to the pressure port of
the MS-DP1-7, tighten to a torque of 9.8 N·m or less.
‡An conversion bushing is available for when using the DP-10Ƒ-M short 14 mm 0.551 in
spanner
pressure port type. It can be used to switch between this model and the
DP2 / DP3 series. When connecting to the pressure port, use a tightening
torque of 1.0 N·m or less. M5 female thread Rc 1 8 female thread

Conversion bushing MS-DP1-7 ‡The tightening torque should be 1 N·m or less when connecting a
coupling to the pressure port of MS-DP1-FM.
‡The MS-DP1-FƑ flat attachment is available.
If using the MS-DP1-FƑ flat attachment (optional), install by
following the procedures given below.
①Decide the direction of this product to mount with the sensor.

Pressure port
Coupling (Purchase separately.)

Pressure port Pressure port Pressure port


faces downward faces leftward faces rightward
‡When connecting the coupling to the pressure port of
Note: It is not possible to mount this product such MS-DP1-FR/FE/FN, hold the pressure port with a 14 mm 0.551 in
that the pressure port faces upward. spanner and make sure that the tightening torque is 9.8 N·m or
less.
In addition, in order to prevent any leakage, wind a sealing tape
on the coupling when connecting.

Pressure port
faces upward
②Mount this product with the M3 female threads of the sensor by
using the attached M3 (length 8 mm 0.315 in) screws. The
tightening torque should be 0.5 N·m or less.
M3 female thread

14 mm 0.551 in
M3 (length 8 mm 0.315 in) spanner
screw (Accessory)

Note: Do not tighten the pressure port by holding the product with the
M3 female thread spanner. It may cause the product breakage.

③Mount this product with the mounting surface by using the


attached M4 (length 20 mm 0.787 in) screws. The tightening Flat attachment
torque should be 1.2 N·m or less. ‡Make sure to mount MS-DP1-FƑ with the sensor properly. If it is
not mounted properly, air leakage may occur.
‡Take care that the excessive mounting and dismounting of this
Groove product may cause deterioration of the O-ring.
‡If you touch the O-ring of MS-DP1-FƑ, or any scratch or dust, etc.
is attached to it, air leakage may occur and the sensing
Connector attached cable performance may deteriorate.
M4 (length 20 mm 0.787 in) Take sufficient care when using and storing MS-DP1-FƑ.
screw (Accessory)
Note: Take care that if the cable with connector is sticking out of the side
groove of this product when mounting, the cable may disconnected.
14
DP-100

PRECAUTIONS FOR PROPER USE

Others PRO mode


‡This product has been developed / produced for industrial use. ‡ If the mode selection key is pressed and held for 5 seconds in
‡Use within the rated pressure range. RUN mode, the mode will switch to PRO mode.
‡Do not apply pressure exceeding the pressure withstandability ‡If the mode selection key is pressed while a setting is being made,
value. The diaphragm will get damaged and correct operation shall the mode will switch to RUN mode. In this case, the settings that
not be maintained. have been changed will be entered.
‡Do not use during the initial transient time (0.5 sec. approx.) after
the power supply is switched on.
Setting item Description
‡Avoid dust, dirt, and steam.
Changes the information in the sub display
‡Take care that the sensor does not come in direct contact with
Sub display switching during RUN mode operation to the desired
water, oil, grease, or organic solvents, such as, thinner, etc. alphanumeric display.
‡Do not insert wires, etc., into the pressure port. The diaphragm will
Display refresh rate Changes the display refresh rate for the
get damaged and correct operation shall not be maintained.
switching pressure value displayed in the main display.
‡Do not operate the keys with pointed or sharp objects.
Hysteresis fix value Sets the hysteresis for EASY mode and window
switching comparator mode. (8 steps)
RUN mode
Linked display color Allows the display color for the main display to
‡7KLVLVWKHQRUPDORSHUDWLQJPRGH
switching be switched in line with the output operation for
(standard type only) comparative output 1 or comparative output 2.
Setting item Description
Allows power consumption to be reduced by
ECO mode setting
Threshold value The threshold values for ON / OFF operation can be changed directly dimming the display or turning it off.
setting by pressing the increment key (UP) and the decrement key (DOWN).
Allows the setting details to be checked via
Setting check code
Zero-adjustment This forces the pressure value display to be reset to zero when codes.
function the pressure port is open on the atmospheric pressure side.
Allows the setting details for the master sensor
Setting copy mode
to be copied to slave sensors.
Key lock function Stops key operations from being accepted.
Reset setting Resets the settings to the factory settings.
Displays the peak value and bottom value for fluctuating
Peak hold /
pressure. The peak value appears in the main display,
bottom hold function
and the bottom value appears in the sub display. Table of codes
2nd digit 4th digit
1st digit Multi-function 3rd digit Standard
Code

MENU SETTING mode Standard type type type only


‡If the mode selection key is pressed and held for 2 seconds in Comparative output 1 NO / NC Comparative output 2 NO / NC Analog voltage output / Threshold Display color for Display
output mode switching output mode switching External input value display main display color linking
RUN mode, the mode will switch to MENU SETTING mode.
Analog voltage Comparative
‡If the mode selection key is pressed while a setting is being made, NO OFF OFF P-1, Lo-1
output Red output 1
the mode will switch to RUN mode. In this case, the settings that EASY
Auto- when ON Comparative
have been changed will be entered. NC NO reference Hi-1 output 2
Setting item Description EASY
Remote Comparative
NO NC
Comparative output 1 zero-adjustment P-2, Lo-2 Green output 1
Sets the output mode for comparative output 1. Hysteresis
output mode setting Analog current when ON Comparative
NC NO Hi-2
output output 2
Comparative output 2 output mode Hysteresis
Sets the output mode for comparative output 2.
setting (standard type only) — Comparative
NO NC ADJ.
Window Always output 1
Analog output / external Allows switching between analog voltage output / comparator red
— — Comparative
input switching analog current output, and auto-reference input / NC NO
Window output 2
(multi-function type only) remote zero-adjust-ment input.
comparator Comparative
— — NC — —
NO / NC switching Sets normally open (NO) or normally closed (NC).
Always output 1
Sets the response time. green Comparative
— — — — — —
The response time can be selected from 2.5 ms, output 2
Response time setting
5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms,
500 ms, 1,000 ms and 5,000 ms.

Allows the color for the main display to be changed.


Display color switching The colors can be set to ‘red / green’ or ‘green / red’
for main display to correspond to ON / OFF output, or it can be fixed
at ‘red’ or ‘green’ all the time.

Unit switching Pressure unit can be changed.


Code

5th digit 6th digit 7th digit 8th digit


Response time Unit switching Display refresh rate ECO mode
2.5 ms MPa 250 ms OFF
5 ms kPa 500 ms STD
10 ms kgf/cm2 1,000 ms FULL
25 ms bar — —
50 ms psi — —
100 ms mmHg — —
250 ms inchHg — —
500 ms — — —
1,000 ms — — —
5,000 ms — — —

15
DP-100

DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from the website.

DP-10Ƒ Sensor

42.5
30 1.673 20
1.181 25.5 7.5 9.5 0.787 Connector
1.004 0.295 0.374

30 20 12
1.181 0.787 0.472

R (PT) 1/ 8
male thread
(North America: NPT 1/ 8)
1.5 M5 female thread
0.059
M3 female thread, 4 0.157 deep

Europe Europe
10 7
0.394 0.276

14
0.551

G 1/ 8
male thread

DP-10Ƒ-M(-P) Sensor

30 20
30 1.181
1.181 0.787
25.5 4.5
1.004 0.177

30 ø8.3 20
1.181 ø0.327 0.787 connector

1.5 M3 female thread, M5 female thread,


0.059 4 0.157 deep 4 0.157 deep

DP-11Ƒ-E-P-- Sensor

47.5
1.870 20
30
1.181 25.5 7 0.787
1.004 0.276 M8 connector

9.5
0.374 20
30
1.181 0.787 14
0.551
4.5
0.177
G 1/8 male thread M5 female thread
1.5 15 7 M3 female thread,
0.059 0.591 0.276 4 0.157 deep

16
DP-100
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from the website.

MS-DP1-1 Sensor mounting bracket (Optional)


ø2.3 Assembly dimensions
ø0.091 Mounting drawing with DP-1Ƒ
22 2-R2.1 R0.083
9.5 0.866 9.5
14.5
0.571 0.374 1 0.374
0.039
14.5
4.2 2-R2.1 R0.083 0.571
0.165 22
0.866 4.2
0.165 25.5
30 2-ø3.5 ø0.138 1.004
1.181 42.5
20 1.673
0.787
13 7.5 9.5
0.512 0.295 0.374

20 R13 45
0.787 R0.512 (0.209
5.3
) 44
1.772 30 12
5.5 1.181 45 0.472
1.732
t2 0.217 1.772
t 0.079 20 30
0.787 15 1.181
0.591 1.5
0.059
Material: Cold rolled carbon steel (SPCC) 30 t2
1.181 t 0.079
(Uni-chrome plated)
Two M3 (length 6 mm 0.236 in) screws with washers are attached.

MS-DP1-5 Sensor mounting bracket (Optional)


Assembly dimensions
Mounting drawing with DP-1Ƒ-M
R6.75
22.75 R0.266
0.896

29.5 ø4.5 16
1.161 ø0.177 0.630
20 28
4.5 0.787 8.5 1.102
0.177 0.335
30
1.181
4.5
44.5 0.177
30 1.752
20
0.787
1.181
(1.949
49.5
) ø8.3
ø0.327
t 1.5 20 49.5
2-ø3.5 ø0.138 t 0.059 0.787 28.5 1.949
13.5 1.122
0.531
20 1.5
ø4.5 0.059
0.787 ø0.177 20 4.5 28 t 1.5
Material: Cold rolled carbon steel (SPCC) 0.787 0.177 1.102 t0.059
29.5 53.5
(Uni-chrome plated) 1.161 2.106
Two M3 (length 6 mm 0.236 in) screws with washers are attached. 30
1.181

MS-DP1-2
MS-DP1-3 Panel mounting bracket (Optional), Front protection cover (Optional)
Assembly dimensions
Mounting drawing with '3Ƒ Panel cut-out dimensions
When 1 unit is installed
0
31í
0
1.220 í0.016
0
31í
0
7.2 1.220 í0.016
18.3 7.5 9.5
39.3
( 1.547 ) 0.283
11
0.720 0.295 0.374
34.5 0.433
1.358 When “n” units are installed horizontally in series When “n” units are
0
installed vertically in series
31í
0
Front 31 1.220 Xn + 3.5 0.138 X (n-1) 1.220 í0.016
protection
(
34.5 20
1.358 0.787 ) cover
12
0.472
0
31í
0
1.220 í0.016
R(PT) 1/ 8 55 2.165
50 male thread 31 1.220 Xn + 3.5 0.138 X (n-1)
1.969 or more
8.7
33.4 0.343 Panel thickness dimension
1.315 1 to 6 mm 0.039 to 0.236 in

33.4 Connector
55 2.165
1.315 M5 female thread, or more
4 0.157 deep Note: The panel thickness should be Note: The panel thickness should be
M3 female thread, 1 to 6 mm 0.039 to 0.236 in. 1 to 6 mm 0.039 to 0.236 in.
(52 2.047 max) 4 0.157 deep
View A
Material: POM (Panel mounting bracket)
Polycarbonate (Front protection cover)

17
DP-100
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from the website.

MS-DP1-4 Panel mounting bracket (Optional)


Assembly dimensions Panel cut-out dimensions
Mounting drawing with DP-10Ƒ 36
1.417 56
2.205
( 42.7
1.681 ) ( 9.7
0.382 ) 26.5
1.043
40 6.5 36 +0.5
0
1.575 0.256 1.417+0.020
0

30 3
1.181 0.118 R 1/ 8 Connector
male thread 80
3.150 36 +0.5
0

12 M5 female 1.417+0.020
0

40 30 42.7 0.472 thread


1.575 1.181 1.681
Panel mounting
bracket body Spacer

Front protection cover (DPX-04) 8


0.315 Panel mounting
Panel thickness dimension 1 to 3.2 mm bracket Note: The panel tickness should be 1 to 32 mm 0.039 to 1.260 in.
0.039 to 0.126 in
Material: Panel mounting bracket body ‡ ‡ ‡ Nylon 6
Panel mounting bracket ‡ ‡ ‡ Stainless steel (SUS304)
Spacer ‡ ‡ ‡ Cold rolled carbon steel (SPCC)(Uni-chrome plated)

MS-DP1-7 Conversion bushing (Optional)


15.8
0.622

14
0.551
3.5 7.8
0.138 0.307 M5 male thread
Gasket
( 0.5
0.020 )
11 0.433 10 0.394 8
0.315

Rc1/8 female thread


Material: Brass (Nickel plated)
Weight: 10 g approx.

MS-DP1-FM Flat attachment (Optional) MS-DP1-FR/FN/FE Flat attachment (Optional)


Assembly dimensions Assembly dimensions
Mounting drawing with DP-10Ƒ-M Mounting drawing with DP-10Ƒ-M
52.5
( 2.067 ) 37
(44.5
1.752 ) 37
1.457 (0.945
24
) 1.457
11.5
11.5 0.453
(
24
0.945 ) 0.453
30 11
1.181 0.433
30 11 52.5 24
1.181 0.433 2.067 0.945
44.5 24
1.752 6.5 0.256
0.945 5.5 0.217 13.5
6.5 0.256 0.531
5.5 0.217
20 2-ø4.3 14
2-ø4.3 ø0.169 ø0.169 0.551 8.5
0.787 20 Product distinguishing mark
24 17.5 0.335
0.689 0.787 MS-DP1-FR: 0 line 17.5
0.945 24 MS-DP1-FN: 1 line 0.689
30 0.945
1.181 30 MS-DP1-FE: 2 line
1.181
M5 female thread Material: Enclosure ‡‡‡Polybutylene
terephthalate (PBT) Pressure port Material: Enclosure ‡‡‡ Polybutylene terephthalate (PBT)
(Glass fiber reinforced) G1/8 female thread (Note) (Glass fiber reinforced)
Pressure port ‡‡‡Stainless steel Pressure port ‡‡‡ Stainless steel (SUS303)
(SUS303) O-ring ‡‡‡ Hydrogenated Nitrile
8.5 0.335 O-ring ‡‡‡Hydrogenated Nitrile Butadiene Rubber (H-NBR)
Butadiene Rubber Weight: 25 g approx. (flat attachment only)
(H-NBR)
Note: MS-DP1-FR has a Two M3 (length 8 mm 0.315 in) screws, two M4
Weight: 15 g approx. (flat attachment only) Rc1/ 8 female thread. (length 20 mm 0.787 in) screws are attached.
Two M3 (length 8 mm 0.315 in) screws, MS-DP1-FN has a
NPT1/ 8 female thread.
two M4 (length 20 mm 0.787 in) screws are
attached.

18
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from the website.

CN-14A(-R)-CƑ Connector attached cable (Optional, CN-14A-C2 is attached to the sensor)


L
Model No. Cable length L (mm in)
(1.378
35
) (1.969
50
) CN-14A(-R)-C1 1,000 39.370
(0.3158 ) (0.3158 ) CN-14A(-R)-C2 2,000 78.740

CN-14A(-R)-C3 3,000 118.110

ø3.7 ø0.146 cable CN-14A(-R)-C5 5,000 196.850

Please contact ..........

2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan


Global Sales Department
■Telephone: +81-568-33-7861 ■Facsimile: +81-568-33-8591
panasonic.net/id/pidsx/global

All Rights Reserved © 2013

No. CE-DP100V2-5 November, 2013 Specifications are subject to change without notice. Printed in Japan

You might also like