Professional Documents
Culture Documents
Pressure Sensor Evolutions To Come
Pressure Sensor Evolutions To Come
Conforming to Certification
Recognition
EMC Directive [DP-101(A)/102(A) only]
2013.11 panasonic.net/id/pidsx/global
Achieved further efficiency with
4 upgrades, keeping the same
operability
Note: The upgrade will be implemented from production in October 2013, based on stock status.
Upgrade 1
Superior visibility
Improved visibility in Digital Display
Improvements to the digital display deliver a wide viewing
angle along with increased clarity. The display pressure
range and set pressure range have also been increased.
Old DP-100 series New DP-100 series
Upgrade 2
Long-distance transmission of analog output
Addition of analog current output capability to multifunctional models
Users can now select either voltage output or current output as analog output according to their
application.
Upgrade 3
Reduced environmental impact 14 % lower
after update
14% lower power consumption
(during normal operation)
Thanks to a redesign of its circuitry, power consumption of
Old DP-100 series New DP-100 series
the low-power-consumption DP-100 series during normal 840 mW (normal operation) 720 mW (normal operation)
operation has been reduced by 14%. The display is shut
off entirely during ECO / FULL mode operation for power Up to 50
% lower
in ECO mode
savings of up to 50% compared to normal operation, and
display brightness is lowered during ECO / STD mode
operation for power savings of up to 30% compared to Normal operation ECO / FULL operation
720 mW 360 mW
normal operation.
Upgrade 4
Enhanced power circuitry
Addition of a reverse polarity protection circuit to the
transistor output circuit
To prevent from breakage due to miswiring.
1
Dual Display
A new global standard Direct setting
Threshold value
ect setting
Dir
OFF: Green (or Red) ON: Red (or Green) SET: Orange
Main
Display
2
Copy function helps operation to be accurate and quick
+V +V
0V 0V
Comparative Comparative
output 1 output 1
Comparative Comparative
output 2 output 2
Details transmitted
Details received
Detail
s cop
ied
Note: Settings cannot be copied from the new version (Ver. 2) to the old version.
However, settings can be copied from the old version to the new version (Ver. 2).
Advantage
1 Setting man-hours are reduced and sensor setting time is shortened.
Reduction
3rd equipment:
5 minutes of lead time
approx.
Advantage
2 Human operating error is reduced.
Because all details are copied automatically, problems as a result of human error can be
prevented.
Instruction manuals can be updated easily when changes are made to equipment design.
3
Setting is smooth and easy
PRO mode
RUN operation RUN mode While setting MENU SETTING mode PRO mode
or
Default settings that can be used straight away Buttons with good clicking touch
Easy-to-use default settings are provided for applications that are The buttons have a good clicking touch,
used frequently by pressure sensors. The default settings for low allowing smooth setting.
pressure types are ideal for suction confirmation applications, and
those for high pressure types are ideal for checking reference
pressure.
4
Full range of performance and functions in a compact body
All lineup models are compound pressure High performance accomplished Low pressure type
types The low pressure type displays measurements in 0.1 kPa at a
No sensor settings are required to switch between positive pressure resolution of 1/2,000 and has a response time of 2.5 ms (variable up
and negative pressure, so that the number of registered part to 5,000 ms), ±0.5 % F.S. temperature characteristics and ±0.1 %
numbers can be decreased. F.S. repeatability, achieving high detection performance.
Equipped with independent dual output Standard type Three output modes are suitable for a wide
Equipped with two independent comparative outputs, and separate range of applications
sensing modes can be selected for each of them. Since there are
two comparative outputs, one of the comparative outputs can even
be used for alarm output. In addition, output, which is not being
1 EASY mode
used, can be disabled. This mode is used for comparative output ON / OFF control.
suction applications! P
0
ON ON
Comparative output 1 Comparative output H: Fixed
OFF
EASY mode Suction checking
OFF Notes: 1) Hysteresis can be fixed to one of eight different levels.
2) “ ” appears in the sub display for comparative output 1,
and “ ” appears for comparative output 2.
ON
Comparative output 2
EASY mode
2 Hysteresis mode
OFF
Vacuum breakdown checking This mode is used for setting comparative output hysteresis to
the desired level and for carrying out ON / OFF control.
– 100 kPa P-1 0 kPa P-2
Pressure
Hi
H (Hysteresis)
Lo
Ɣ Reference pressure alarm output is possible during 0
reference pressure checking! Comparative output
ON
H: 1 digit or more
OFF
Comparative output 1 ON Reference Note: “ ” or “ ” appears in the sub display for comparative
Hysteresis pressure output 1, and “ ” or “ ” appears for comparative output 2.
mode checking
OFF
Hi
H (Hysteresis)
0 kPa Lo-1 Hi-1 P-2
Lo
0
ON
Comparative output H: Fixed
OFF
5
Equipped with auto-reference / remote zero-adjustment functions,
More precise pressure management is achieved with a minimum of effort Multi-function type
If the reference pressure of the
device changes, two functions Without auto-reference and remote zero-adjustment functions
are selectable. One is Comparative output: Window comparator mode
auto-reference function, which Hi-1 30, Lo-1 25
partially shift the comparative Fixed set value
output judgment level by the
amount that the reference 40
pressure shifts. The other is NG?
remote zero-adjustment 30
function, which can reset the Leak threshold level
OK
display value to zero via 25
external input. These functions 20
are ideal for places where the NG?
reference pressure fluctuates 15
wildly, or where fine settings are Variation in the filling pressure
Trial 1
required. Trial 2
Trial 3
Pressure
0 Time
Because the threshold level is fixed for conventional pressure sensors,
changes in the reference pressure result in wrong decisions.
30 30
0
25 OK 25 –5 OK
20 20
Threshold level after applying Threshold level after applying
15 auto-reference input remote zero-adjustment input
15
Threshold level before applying Threshold level before applying
auto-reference input remote zero-adjustment input
Trial 1 Trial 1
Pressure 0 Pressure 0
Displayed when remote zero-
–5 Auto-reference input value –5 adjustment input is applied
Time Time
When auto-reference input is applied, the reference pressure “30” is When remote zero-adjustment input is applied, the reference pressure is forced to “0”.
added to the threshold level. If the reference pressure changes to “20” or If the reference pressure changes to “20” or “40”, the remote zero-adjustment input
“40”, the auto-reference input compensates for this every time by changing adjusts the reference pressure to “0” every time the reference pressure changes, so
the threshold level, so any variation in the filling pressure can be ignored. any variation in the filling pressure can be ignored.
Peak hold and Bottom hold functions Energy-saving design! Equipped with an ECO mode
The peak values and bottom values for fluctuating pressures can be This mode lowers the display luminance to cut power consumption
displayed using the dual display. by approximately 30 %. The displays can also be turned off
completely to achieve a power saving of approximately 40 %.
Power consumption Power consumption
Approx. Approx.
Normal ECO-STD 30 % less ECO-FULL 40 % less
Blinks alternately
6
Other useful functions
What are the check The code on the main display is 3205.
codes for the setting? The sub display shows 7011.
Environmentally
friendly
Commercially-available
Connection cable * parts can be used!
Ɣ M8 plug-in connector types are also available (Only for Europe) DP-11Ƒ-E-P-J
M8 connector
Mating cable
CN-24A-C2 (cable length 2 m 6.562 ft)
CN-24A-C5 (cable length 5 m 16.404 ft)
7
Installation is also easy!
Neat and
Front protection
space cover available
Tight installation is possible saving MS-DP1-3
Elbow joint
8
DP-100
Flat installation on the wall by shifting the direction Rc1/8 conversion bushing is available. Compatible
of the pressure port For short pressure port type with previous model For short pressure port type
By mounting the flat attachment By equipping the push-in converter with DP-10Ƒ-M(-P), pressure
Previous model DP2 / DP3
to DP-10Ƒ-M(-P), pressure port series can be switched over to port can be converted from M5 female thread to Rc1/8 female thread.
and cable can now be pulled out DP-100 series. Bore diameter conversion to the DP2 / DP3 series is possible.
in downward, left or right
Previous model
directions. Flat mounting on M5 female thread Rc1/8 female thread
surfaces such as the wall is
made possible.
Flat attachment
06'3)Ƒ 20 mm 20 mm
0.787 in pitch 0.787 in pitch
Conversion bushing
Model No. Pressure port
MS-DP1-7
MS-DP1-FM M5 female thread
MS-DP1-FR Rc1/8 female thread
MS-DP1-FN NPT1/8 female thread
MS-DP1-FE G1/8 female thread
ORDER GUIDE
Type Appearance Rated pressure range Model No. Pressure port Comparative output
M5 female thread
DP-101A-M NPN open-collector transistor
For low pressure í100.0 to +100.0 NPa
DP-101A-M-P PNP open-collector transistor
Multi-function
DP-102A-M NPN open-collector transistor
For high pressure í0.100 to +1.000 MPa
DP-102A-M-P PNP open-collector transistor
Accessory
CN-14A-C2
(Connector attached cable 2 m 6.562 ft)
9
DP-100
OPTIONS
ñ101
.3kP
a
OUT
0-AD 2
J
MOD
E
can be installed on
MS-DP1-4.
Front protection cover Remove
MS-DP1-3
MS-DP1-5
Insert M3 (length 6 mm 0.236 in)
DP-100 Mounting holes screws with washers
for DP2 / DP3 series
can be used as is. (Accessory for
MS-DP1-5 )
Panel mounting bracNet Panel mounting bracNet MS-DP1-4
MS-DP1-2
Sensor mounting
bracNet
Flat attachment MS-DP1-5
MS-DP1-FM MS-DP1-FR
MS-DP1-FN
MS-DP1-FE
10
DP-100
SPECIFICATIONS
Standard Multi-function
Type
For low pressure For high pressure For low pressure For high pressure
Asia (Note 2) DP-101(-M)(-P) DP-102(-M)(-P) DP-101A(-M)(-P) DP-102A(-M)(-P)
Model No.
Pressure withstandability 500 kPa 1.5 MPa 500 kPa 1.5 MPa
Applicable fluid Non-corrosive gas
Selectable unit For low pressure: kPa, kgf/cm2, bar, psi, mmHg, inHg, For high pressure: MPa, kPa, kgf/cm2, bar, psi
Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less
Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
Power consumption ECO mode: 480 mW or less at STD (Current consumption 20 mA or less at 24 V supply voltage)
360 mW or less at FULL (Current consumption 15 mA or less at 24 V supply voltage)
<Asia (NPN output), North America (NPN output)> <Asia (PNP output), Europe, North America (PNP output)>
NPN open-collector transistor PNP open-collector transistor
Comparative output Ma[imum sink current: 100 mA Ma[imum source current: 100 mA
Applied voltage: 30 V DC or less (between comparative output and 0 V) Applied voltage: 30 V DC or less (between comparative output and +V)
Residual voltage: 2 V or less (at 100 mA sink current) Residual voltage: 2 V or less (at 100 mA source current)
Output operation / Output modes NO / NC (selectable by key operation) / EASY mode / Hysteresis mode / Window comparator mode
Hysteresis Minimum 1 digit (variable) (however, 2 digits when using psi unit)
Repeatability ±0.1 % F.S. (within ±2 digits) ±0.2 % F.S. (within ±2 digits) ±0.1 % F.S. (within ±2 digits) ±0.2 % F.S. (within ±2 digits)
Response time 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Short-circuit protection Incorporated
<Asia (NPN output), North America (NPN output)> <Asia (PNP output), Europe, North America (PNP output)>
E[ternal input (Note 3)
ON voltage: 0.4 V DC or less ON voltage: 5 V to +V DC
Auto-reference function /
OFF voltage: 5 to 30 V DC, or open OFF voltage: 0.6 V DC or less, or open
Remote zero-adjustment
,nput impeGance: 0 Nȍ appro[. Input impeGance: 10 Nȍ appro[.
function
Input time: 1 ms or more Input time: 1 ms or more
Output voltage: 1 to 5 V DC Output voltage: 0.6 to 5 V
Zero point: within 3 V ±5 % F.S. Zero point: within 1 V ±5 % F.S.
Analog voltage output (Note 3) Span: within 4 V ±5 % F.S. Span: within 4.4 V ±5 % F.S.
Linearity: within ±1 % F.S. Linearity: within ±1 % F.S.
Output impeGance: 1 Nȍ appro[. Output impeGance: 1 Nȍ appro[.
Output current: 4 to 20 mA Output current: 2.4 to 20 mA
Zero point: 12 mA ±5 % F.S. Zero point: 4 mA ±5 % F.S.
Analog current output (Note 3) Span: 16 mA ±5 % F.S. Span: 17.6 mA ±5 % F.S.
Linearity: within ±1 % F.S. Linearity: within ±1 % F.S.
LoaG resistance: 250 ȍ (ma[.) LoaG resistance: 250 ȍ (ma[.)
Display 4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
í101.0 to +101.0 kPa í0.101 to +1.010 MPa í101.0 to +101.0 kPa í0.101 to +1.010 MPa
í1.030 to +1.030 kgf/cm2 í101 to +1,010 kPa í1.030 to +1.030 kgf/cm2 í101 to +1,010 kPa
í1.010 to +1.010 bar í1.03 to +10.30 kgf/cm2 í1.010 to +1.010 bar í1.03 to +10.30 kgf/cm2
Displayable pressure range í14.64 to +14.64 psi í14.64 to +14.64 psi
í1.01 to +10.10 bar í1.01 to +10.10 bar
í757 to +757 mmHg í757 to +757 mmHg
í29.8 to 29.8 inHg í14.6 to +146.4 psi í29.8 to 29.8 inHg í14.6 to +146.4 psi
Orange LED Orange LED
Indicator
( Comparative output 1 operation indicator, comparative output 2 operation indicator:
Lights up when each comparative output is ON )( Comparative output 1 operation indicator: Lights up when comparative output is ON,
Analog voltage output operation indicator: Lights up when setting )
Protection IP40 (IEC)
Environmental resistance
Ambient temperature í10 to +50 °C +14 to +122 °F, Storage: í10 to +60 °C +14 to +140 °F
Ambient humidity 35 to 85 % RH (No dew condensation or icing allowed), Storage: 35 to 85 % RH
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50Mȍ or more with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 500 Hz frequency, 3 mm 0.118 in amplitude, in X, Y and Z directions for two hours each (when panel is mounted: 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude, in X, Y and Z directions for two hours each)
Shock resistance 100 m/s2 acceleration (10 G appro[.) in X, Y and Z directions for three times each
Temperature characteristics Within ±0.5 % F.S. (at +20 °C +68 °F) Within ±1 % F.S. (at +20 °C +68 °F) Within ±0.5 % F.S. (at +20 °C +68 °F) Within ±1 % F.S. (at +20 °C +68 °F)
Pressure port Asia: M5 female thread + R (PT) 1/8 male thread >e[cluding DP-Ƒ-M(-P)], Europe: M5 female thread + G 1/8 male thread, North America: M5 female thread + NPT 1/8 male thread
Material Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS303) , Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber
Connecting method / Cable length Connector / Total length up to 100 m 328.084 ft (less than 30 m 98.425 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable
Weight Net weight: 40 g appro[. (DP-10Ƒ-M(-P): 30 g appro[.), Gross weight: 135 g appro[. (DP-10Ƒ-M(-P):125 g appro[.)
Accessories CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1pc. (e[cluding M8 plug-in connector type)
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) Model Nos. of Asia type having “-M´ are short pressure port type. Model Nos. of Asia and North America types having the suffi[ “-P” are PNP output type.
3) Cannot be used at the same time.
11
DP-100
Sensor circuit
3
D2 Load or E[ternal input Load
Comparative output 1 + 12 to 24 V DC
Sensor circuit
Tr1 2
Load 1kȍ D2 (Black) Comparative output 1
100 mA ma[. + í ±10 %
12 to 24 V DC Tr2 2
ZD1 D3 (White) Comparative output 2 ±10 %
Tr2 3 í 100 mA ma[.
ZD1
100 mA ma[. (Blue) 0 V
ZD2 4
(Blue) 0 V
4 Internal circuit Users’ circuit
Internal circuit Users’ circuit
Symbols D1, D2 : Reverse supply polarity protection diode
Symbols D : Reverse supply polarity protection diode ZD1 : Surge absorption zener diode
ZD1, ZD2 : Surge absorption zener diode Tr1 : PNP input transistor
Tr1, Tr2 : NPN output transistor Tr2 : NPN output transistor
ZD1 2 +
100 mA ma[.
Sensor circuit
12
DP-100
Sensor circuit
Tr1 100 mA max.
ZD1 4 +
Sensor circuit
Condition
The line to connect with this sensor should be less than
30 m 98.425 ft.
13
DP-100
Mounting Piping
The MS-DP1-4 panel mounting bracket is available when If connecting a commercially-available 12 mm 0.472 in
spanner
switching from the DP2 / DP3 series. coupling to the pressure port, attach a
DP2 / DP3 12 mm 0.472 in spanner (14 mm 0.551 in
DP
2-2
0
ñ10
1.3k
Pa
spanner for DP-100-E type) to the hexagonal
Front protective cover OUT
1
$'
-
OUT
MO
2
Conversion bushing MS-DP1-7 The tightening torque should be 1 N·m or less when connecting a
coupling to the pressure port of MS-DP1-FM.
The MS-DP1-FƑ flat attachment is available.
If using the MS-DP1-FƑ flat attachment (optional), install by
following the procedures given below.
①Decide the direction of this product to mount with the sensor.
Pressure port
Coupling (Purchase separately.)
Pressure port
faces upward
②Mount this product with the M3 female threads of the sensor by
using the attached M3 (length 8 mm 0.315 in) screws. The
tightening torque should be 0.5 N·m or less.
M3 female thread
14 mm 0.551 in
M3 (length 8 mm 0.315 in) spanner
screw (Accessory)
Note: Do not tighten the pressure port by holding the product with the
M3 female thread spanner. It may cause the product breakage.
15
DP-100
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from the website.
DP-10Ƒ Sensor
42.5
30 1.673 20
1.181 25.5 7.5 9.5 0.787 Connector
1.004 0.295 0.374
30 20 12
1.181 0.787 0.472
R (PT) 1/ 8
male thread
(North America: NPT 1/ 8)
1.5 M5 female thread
0.059
M3 female thread, 4 0.157 deep
Europe Europe
10 7
0.394 0.276
14
0.551
G 1/ 8
male thread
DP-10Ƒ-M(-P) Sensor
30 20
30 1.181
1.181 0.787
25.5 4.5
1.004 0.177
30 ø8.3 20
1.181 ø0.327 0.787 connector
DP-11Ƒ-E-P-- Sensor
47.5
1.870 20
30
1.181 25.5 7 0.787
1.004 0.276 M8 connector
9.5
0.374 20
30
1.181 0.787 14
0.551
4.5
0.177
G 1/8 male thread M5 female thread
1.5 15 7 M3 female thread,
0.059 0.591 0.276 4 0.157 deep
16
DP-100
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from the website.
20 R13 45
0.787 R0.512 (0.209
5.3
) 44
1.772 30 12
5.5 1.181 45 0.472
1.732
t2 0.217 1.772
t 0.079 20 30
0.787 15 1.181
0.591 1.5
0.059
Material: Cold rolled carbon steel (SPCC) 30 t2
1.181 t 0.079
(Uni-chrome plated)
Two M3 (length 6 mm 0.236 in) screws with washers are attached.
29.5 ø4.5 16
1.161 ø0.177 0.630
20 28
4.5 0.787 8.5 1.102
0.177 0.335
30
1.181
4.5
44.5 0.177
30 1.752
20
0.787
1.181
(1.949
49.5
) ø8.3
ø0.327
t 1.5 20 49.5
2-ø3.5 ø0.138 t 0.059 0.787 28.5 1.949
13.5 1.122
0.531
20 1.5
ø4.5 0.059
0.787 ø0.177 20 4.5 28 t 1.5
Material: Cold rolled carbon steel (SPCC) 0.787 0.177 1.102 t0.059
29.5 53.5
(Uni-chrome plated) 1.161 2.106
Two M3 (length 6 mm 0.236 in) screws with washers are attached. 30
1.181
MS-DP1-2
MS-DP1-3 Panel mounting bracket (Optional), Front protection cover (Optional)
Assembly dimensions
Mounting drawing with '3Ƒ Panel cut-out dimensions
When 1 unit is installed
0
31í
0
1.220 í0.016
0
31í
0
7.2 1.220 í0.016
18.3 7.5 9.5
39.3
( 1.547 ) 0.283
11
0.720 0.295 0.374
34.5 0.433
1.358 When “n” units are installed horizontally in series When “n” units are
0
installed vertically in series
31í
0
Front 31 1.220 Xn + 3.5 0.138 X (n-1) 1.220 í0.016
protection
(
34.5 20
1.358 0.787 ) cover
12
0.472
0
31í
0
1.220 í0.016
R(PT) 1/ 8 55 2.165
50 male thread 31 1.220 Xn + 3.5 0.138 X (n-1)
1.969 or more
8.7
33.4 0.343 Panel thickness dimension
1.315 1 to 6 mm 0.039 to 0.236 in
33.4 Connector
55 2.165
1.315 M5 female thread, or more
4 0.157 deep Note: The panel thickness should be Note: The panel thickness should be
M3 female thread, 1 to 6 mm 0.039 to 0.236 in. 1 to 6 mm 0.039 to 0.236 in.
(52 2.047 max) 4 0.157 deep
View A
Material: POM (Panel mounting bracket)
Polycarbonate (Front protection cover)
17
DP-100
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from the website.
30 3
1.181 0.118 R 1/ 8 Connector
male thread 80
3.150 36 +0.5
0
12 M5 female 1.417+0.020
0
14
0.551
3.5 7.8
0.138 0.307 M5 male thread
Gasket
( 0.5
0.020 )
11 0.433 10 0.394 8
0.315
18
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from the website.
No. CE-DP100V2-5 November, 2013 Specifications are subject to change without notice. Printed in Japan