BDU A (OLD) TYPE 30 AMP (1006-0111) NOTE: SW7 IS ON BDC (LOWER) BOARD
BDU A (OLD) TYPE 50 AMP (1006-0112) NOTE: SW7 IS ON BDC (LOWER) BOARD
BDU A (OLD) TYPE 75 AMP (1006-0113) NOTE: SW7 IS ON BDC (LOWER) BOARD
BDU A (NEW) TYPE 30 AMP (1006-0111) NOTE: SW7 IS ON BDC (LOWER) BOARD
MOTOR BL-25E-20 BL50E-20 BL-H50E-20 BL-H100E-12 BL-M55OE-20 BL-M550E-20-1
SW1 356 1245 1245 6 136 136
SW2 356 1245 1245 6 136 136
SW3U 23 123 23 13 24 14
SW3V 23 123 23 13 24 14
SW4U 34 34 3 34 34 3
SW4V 34 34 3 34 34 3
SW5 246 56 56 46 46 46
SW6 - - - - - -
SW7 1 1 1 1 1 1
BDU A (NEW) TYPE 50 AMP (1006-0112) NOTE: SW7 IS ON BDC (LOWER) BOARD
MOTOR BL-80E-20 BL-80E-30 BL-H100E-20 BL-H200E-12 BL-H100E-30 BL-M55OE-20BL-MS75E-20BL-MS75E-630
SW1 146 12345 136 6 2345 56 56 6
SW2 146 12345 136 6 2345 56 56 6
SW3U 123 123 14 123 4 24 23 24
SW3V 123 123 14 123 4 24 23 24
SW4U 34 3 34 34 3 3 3 3
SW4V 34 3 34 34 3 3 3 3
SW5 146 46 146 46 6 46 46 46
SW6 - - - - - - - -
SW7 2 2 2 2 2 2 2 2
BDU A (NEW) TYPE 75 AMP (1006-0113) NOTE: SW7 IS ON BDC (LOWER) BOARD
MOTOR BL-120E-20 BL-180E-20 BL-120E-30 BL-H200E-20 BL-H300E-20 BL-H300E-12 BL-400E-12 BL-H200E-30 BL-MS125E-20 BL-MS125E-30
SW1 146 6 6 6 6 6 6 6 246 6
SW2 146 6 6 6 6 6 6 6 246 6
SW3U 4 124 34 24 134 123 4 134 4 124
SW3V 4 124 34 24 134 123 4 134 4 124
SW4U 3 134 34 13 134 34 34 13 3 3
SW4V 3 134 34 13 134 34 34 13 3 3
SW5 236 45 36 136 35 236 2345 35 46 36
SW6 - - - - - - - - - -
SW7 3 3 3 3 3 3 3 3 3 3
CNCREPAIR.COM PHONE # 408-331-1970
OKUMA BLD-A AXIS DRIVE SETTING CHART
FOR BOARDS E4809-770-015-B to E4809-770-015-D MARKED SWITCHES ARE ON