PRESENTATION OF PROJECT
This part of the project presents the Architectural, Structural, Electrical and
FIGURE 4.1
Figure 4.1 shows the perspective of the Two-Storey Multi-purpose Building which
FIGURE 4.2
Figure 4.2 shows the Vicinity Map of the Two-Storey Multi-purpose Building
which is located at Golingan I Brgy. Mabuhay, General Santos City, South Cotabato. The
vicinity map shows the location of the building where it will be built.
.
Proposed Two-storey Multi-purpose Building Presentation of Project 39
FIGURE 4.3
Figure 4.3 shows the site development plan of the Two-Storey Multi-purpose
Building which is located at Golingan I Brgy. Mabuhay, General Santos City, South
Cotabato. In site development plan it shows the position of the building in its lot area.
Proposed Two-storey Multi-purpose Building Presentation of Project 40
FIGURE 4.4
Figure 4.4 shows the Ground Floor Plan of the Two-Storey Multi-purpose
Building. A total area of 120 square meter convenience store. It has a two air-conditioned
unit, eating area, cashier counter, one comfort room and a stock room.
Proposed Two-storey Multi-purpose Building Presentation of Project 41
FIGURE 4.5
Figure 4.5 shows the Second Floor Plan of the Two-Storey Multi-purpose
Building. A total area of 120 square meter and consists of five rooms, in each rooms have
a one comfort room, and one bedroom and it has a fire exit.
Proposed Two-storey Multi-purpose Building Presentation of Project 42
FIGURE 4.6
Figure 4.6 shows the Roof deck Plan of Two-Storey Multi-purpose Building. A
total area of 120 square meter and it is for laundry area and recreational area.
Proposed Two-storey Multi-purpose Building Presentation of Project 43
FIGURE 4.7
Figure 4.7 shows Front View of the Two-Storey Multi-purpose Building. The total
height of the multi-purpose building which measure 8.70m above the finish floor line. In
this front view you can see the signage, translucent glass was used in the convenience
FIGURE 4.8
Figure 4.8 shows Left View of the Two-Storey Multi-purpose Building. The total
height of the multi-purpose building which measure 8.70m above the finish floor line.
Tinted translucent glass was used in the convenience store and a steel stair for the fire
exit.
Proposed Two-storey Multi-purpose Building Presentation of Project 45
FIGURE 4.9
Figure 4.9 shows Rear or Back View of the Two-Storey Multi-purpose Building.
The total height of the multi-purpose building which measure 8.70m above the finish
floor line.
Proposed Two-storey Multi-purpose Building Presentation of Project 46
FIGURE 4.10
Figure 4.10 shows Right View of the Two-Storey Multi-purpose Building, the
total height of the multi-purpose building which measure 8.70m above the finish floor
line.
Proposed Two-storey Multi-purpose Building Presentation of Project 47
FIGURE 4.11
the total height of the multi-purpose building which measure 8.70m above the finish floor
line. It shows what is inside the building. A convenience store at ground floor and a
FIGURE 4.12
Building, the total height of the multi-purpose building which measure 8.70m above the
finish floor line. It shows what is inside the building. A stock room and comfort room at
ground floor and a room at the second floor. It also shows the design of stair.
Proposed Two-storey Multi-purpose Building Presentation of Project 49
FIGURE 4.13
Figure 4.13 shows the doors and windows details of Multi-purpose Building, the
total height of the multi-purpose building which measure 8.70m above the finish floor
FIGURE 4.14
Figure 4.14 shows Stairs Details of Multi-purpose Building, the total height of the
multi-purpose building which measure 8.70m above the finish floor line. Stairs has a 200
FIGURE 4.15
Figure 4.15 shows ground floor lighting plan of the Two-Storey Multi-purpose
Building. It has two circuits, circuit one has 13 lighting outlets and circuit two has five
FIGURE 4.16
Figure 4.16 shows second floor lightning plan of the Two-Storey Multi-purpose
Building. At the second floor, circuit two has four lightning outlets and circuit three has
15 lightning outlets.
Proposed Two-storey Multi-purpose Building Presentation of Project 53
FIGURE 4.17
Figure 4.17 shows roof deck lightning plan of the Two-Storey Multi-purpose
Building. At the roof deck, circuit four has five lightning outlets.
Proposed Two-storey Multi-purpose Building Presentation of Project 54
FIGURE 4.18
Figure 4.18 shows ground floor power plan of the Two-Storey Multi-purpose
FIGURE 4.19
Figure 4.19 shows second floor power plan of the Two-Storey Multi-purpose
Building. Second floor has only one circuit and it has 15 convenient outlets.
Proposed Two-storey Multi-purpose Building Presentation of Project 56
FIGURE 4.20
Figure 4.20 shows roof deck power plan of the Two-Storey Multi-purpose
Building. Roof deck has only one circuit and it has 3 water proof convenient outlets.
Proposed Two-storey Multi-purpose Building Presentation of Project 57
FIGURE 4.21
SCALE: NTS
Figure 4.21 shows the Location of Electrical Plan of the Two-Storey Multi-
purpose Building.
Proposed Two-storey Multi-purpose Building Presentation of Project 58
LEGENDS:
SERVICE ENTRANCE
M KWH-METER
CIRCUIT BREAKER
GENERAL NOTES
1. ALL ELECTRICAL WORKS SHALL CONFORM WITH THE LATEST EDITION
OF PHILIPPINE ELECTRICAL CODE AND STANDARDS SET BY THE LOCAL
AUTHORITIES.
2. STANDARD TYPE OF ACCESSORIES, SPLICING DEVICES TERMINATION
AND OTHER APPLIANCES FOR ENTIRE ELECTRICAL INSTALLATION
SHALL BE USED.
3. ALL MATERIALS SHALL BE NEW AND OF APPROVED TYPE.
4. MINIMUM SIZE OF POWER LINES FOR LIGHTINGS AND OUTLETS SHALL
BE 2.0mmØ THWN COPPER WIRE,STRANDED.
5. ALL METAL FRAME SHALL BE PROPERLY GROUNDED AND BONDED
TOGETHER THAT SHALL CONFORM WITH THE LATEST EDITION OF
PHILIPPINE ELECTRICAL CODE.
6. CONVENIENCE OUTLETS SHALL BE LAID OUT 30.48cm ABOVE THE
FLOOR.
7. LIGHT SWITCHES SHALL BE MOUNTED ON THE WALL OF 1.40m ABOVE
THE FLOOR.
8. POWER LINES FROM THE TRANSFORMER GOING TO THE LIGHTING
PANEL SHALL BE CONCEALED IN A PVC PIPE.
9. MAIN DISTRIBUTION LINES SHALL BE IN WIRE TRAY AND POWER LINES
GOING TO ITS SPECIFIC LOAD SHALL BE CONCEALED IN A PVC PIPE.
ALL SPLICING SHALL BE DONE IN A SPLICING BOXES. THERE WILL BE
NO OPEN WIRING.
10. POWER SERVICE TO THE SUPPLIES SHALL BE 220 VOLTS.
11. ALL ELECTRICAL WORKS SHALL BE UNDER THE DIRECT SUPERVISION
OF A LICENSED ELECTRICAL OR MASTER ELECTRICIAN.
FIGURE 4.22
SCALE: NTS
Figure 4.22 shows the Single Line Diagram for the Electrical Plan the Two-Storey
Multi-purpose Building.
Proposed Two-storey Multi-purpose Building Presentation of Project 59
Table 4.1 shows the Typical Panel Board Schedule of Loads for the Electrical Plan
FIGURE 4.23
SCALE: NTS
Figure 4.23 shows the Waterline Plan Layout for Ground Floor of the Two-Storey
Multi-purpose Building.
Proposed Two-storey Multi-purpose Building Presentation of Project 61
FIGURE 4.24
SCALE: NTS
Figure 4.24 shows the Waterline Plan Layout for Second Floor of the Two-Storey
Multi-purpose Building.
Proposed Two-storey Multi-purpose Building Presentation of Project 62
FIGURE 4.25
SCALE: NTS
Figure 4.25 shows the Waterline Plan Layout for Second Floor of the Two-Storey
Multi-purpose Building.
Proposed Two-storey Multi-purpose Building Presentation of Project 63
FIGURE 4.26
SCALE: NTS
Figure 4.26 shows the Isometric Waterline Plan Layout of the the Two-Storey
Multi-Purpose Building.
Proposed Two-storey Multi-purpose Building Presentation of Project 64
FIGURE 4.27
SCALE: NTS
Figure 4.27 shows the Sewer Plan Layout for Ground Floor of the Two-Storey
Multi-purpose Building.
Proposed Two-storey Multi-purpose Building Presentation of Project 65
FIGURE 4.28
SCALE: NTS
Figure 4.28 shows the Sewer Plan Layout for Second Floor of the Two-Storey
Multi-purpose Building.
Proposed Two-storey Multi-purpose Building Presentation of Project 66
FIGURE 4.29
SCALE: NTS
Figure 4.29 shows the Sewer Plan Layout for roof deck of the Two-Storey Multi-
purpose Building.
Proposed Two-storey Multi-purpose Building Presentation of Project 67
FIGURE 4.30
SCALE: NTS
Figure 4.30 shows the Isometric Sewer Plan Layout of the Two-Storey Multi-
purpose Building.
Proposed Two-storey Multi-purpose Building Presentation of Project 68
Ø PVC S RY
TEE % SLOPE)
FIGURE 4.31
SCALE: NTS
Figure 4.31 shows the Septic Tank Details of Two-Storey Multi-Purpose Building.
It is a three-chamber septic tank.