Timer (RRC)
Following table is from 36.331 7.3 Timers (Informative)
Timer Start Stop At expiry
T300 Transmission of RRCConnectionRequest Reception of RRCConnectionSetup or Perform the
RRCConnectionReject message, cell actions as
re-selection and upon abortion of specified in
connection establishment by upper 5.3.3.6
layers
T301 Transmission of Reception of Go to RRC_IDLE
RRCConnectionReestabilshmentRequest RRCConnectionReestablishment or
RRCConnectionReestablishmentReject
message as well as when the selected
cell becomes unsuitable
T302 Reception of RRCConnectionReject Upon entering RRC_CONNECTED and Inform upper
while performing RRC connection upon cell re-selection layers about
establishment barring alleviation
as specified in
5.3.3.7
T303 Access barred while performing RRC Upon entering RRC_CONNECTED and Inform upper
connection establishment for mobile upon cell re-selection layers about
originating calls barring alleviation
as specified in
5.3.3.7
T304 Reception of Criterion for successful completion of In case of cell
RRCConnectionReconfiguration handover to EUTRA or cell change change order
message including the MobilityControl order is met (the criterion is specified from E-UTRA or
Info or reception of in the target RAT in case of inter-RAT) intra E-UTRA
MobilityFromEUTRACommand message handover, initiate
including CellChangeOrder the
RRCconnection
re-establishment
procedure; In
case of handover
to E-UTRA,
perform the
actions defined in
the specifications
applicable for the
source RAT.
T305 Access barred while performing Upon entering RRC_CONNECTED and Inform upper
RRCconnection establishment for upon cell re-selection layers about
mobile originating signalling barring alleviation
as specified in
5.3.3.7
T310 Upon detecting physical layer problems Upon receiving N311 consecutive in- If security is not
i.e. upon receiving N310 consecutive sync indications from lower layers, activated: go to
out-of-sync indications from lower layers upon triggering the handover RRC_IDLE
procedure and upon initiating the
connection re-establishment else: initiate the
procedure connection re-
establishment
procedure
T311 Upon initiating the RRCconnection Selection of a suitable E-UTRA cell or a Enter RRC_IDLE
reestablishmentmprocedure cell using another RAT.
T320 Upon receiving t320 or upon cell Upon entering RRC_CONNECTED, Discard the cell
(re)selection to E-UTRA from another when PLMN selection is performed on reselection
RAT with validity time configured for request by NAS, or upon cell priority
dedicated priorities (in which case the (re)selection to another RAT (in which information
remaining validity time is applied). case the timer is carried on to the provided by
other RAT). dedicated
signalling.
T321 Upon receiving measConfig including a Upon acquiring the information Initiate the
reportConfig with the purpose set to needed to set all fields of cellGlobalId measurement
reportCGI for the requested cell, upon receiving reporting
measConfig that includes removal of procedure, stop
the reportConfig with the purpose set performing the
to reportCGI related
measurements
and remove the
corresponding
measId