The control of Indoor Air Quality Berlin, Ecosummit,

19 May 2015
Indoor Air Quality becomes a major human health concern

Everyday !
Food Water Air
1 kg 2 kg 12 kg
Uncontrolled source

s
s
Human breath indoor air
more than 80% of its time s A growing Regulatory context

Body exposure to
Many chemical pollution
sources
s environment pollutants
induces and/or accelerates
diseases
More and more hermetic
Impact of indoor air quality
buildings
starts to be quantified

Considering Indoor Air Impact on Health,


Authorities are enforcing Regulations
2
Because pollution becomes visible Shanghai 5 Feb 2015

3
Paris, 20 March 2015

4
An increasing global market

CAGR
Total Market 2013-2018**
2014*

$ 3,3B +7.3 %

Developed countries Emerging countries

• High environmental concern • Big polluted megalopolis


• Buildings performances Labels • People want to feel protected in
(LEED, HQE, BREEAM…) their homes

à Manage Energy à Purification to ensure


efficiency & Health in an healthy air in house
buildings and transportation

* Sources : *Navigant Research, **TechNavio 2014 5


Mastering indoor air quality implies multiple skills

Diagnosis Purification
ü Few identified risky
pollutants (formaldehyde,
benzene, VOCs…)

ü At very low concentrations


part per billions

Monitoring

A global need of efficient technologies enabling to concentrate


6
selectively pollutants
Existing products
Diagnosis Monitoring Purification

Profil’air
• Formaldehyde
• Active & Passive sampling,
• Individual exposure
• Emission & source detection

Manon: IAQ Monitor


• CO2, Formaldehyde, Light
Trichlor’air VOCs, T°, RH
• NCl3 - Nitrogen • Continuous measurement
trichloride • 7-years autonomy
• Active sampling • Customized communication to
proprietary system

PureTECH
filtering media
NEMo : IAQ Logger • Proven long-term efficiency
• CO2, Formaldehyde, Light for formaldehyde
VOCs, T°, RH • No retro-diffusion
• Continuous measurement • Saturation level indicator
• Autonomous • Integration in
• 1 press-button diagnosis Rowenta/Supor air purifier
• Easy Report edition

7
Diagnosis products roadmap

2015 2016 > 2017

NEMo Pool
• NCl3 - Nitrogen trichloride
• Passive sampling ü More parameters
• Continous measurement ü Higher performances
• Individual exposure ü Lower cost
ü Easy intuitive use
NEMo 1.2 NEMo 2
• TCOV • PM10, CO, O3
• Bluetooth • Active sampling
• iOS, Android app • Communicating hub

NEMo 3
• Aldéhyde, BTEX, Low Cost
CO2
• Higher sensor performance
• Cost reduction

From IAQ to Medical


applications : CO2 &
8
Bacterial contamination
Monitoring products roadmap

2015 2016 > 2017

Manon I/O Supply an efficient IAQ


• TCOV, PM10, CO, O3, NO2
• Outdoor module
Intelligence I/O to buildings
• Communicating hub
• Cloud software ü Dashboard & Report
• Indoor intelligence I/O
ü Actions
ü Air Purifier & HVAC
management

Manon Waterplant
• H2S, Mercaptan

From IAQ monitoring to


intelligent buildings

9
Pure air needs smart devices and intelligence

Different possible strategies depending on


indoor/outdoor pollutant

Outdoor
pollutants

VENTILATE
Indoor
pollutants

PURIFY

CONFORT

ENERGY REDUCTION

10
Purification products roadmap

2015 2016 > 2017

Formaldehyde
Formaldehyde • Individual protection
Formaldehyde
• Consumer air Purifier • HVAC systems molecular filter

O3 – NOx

VOCs & Odors


• Aldehyde
• BTEX
• H2S, Mercaptan…

11
A unique technology with 6 patent Families
Proprietary SolGel Customized electronic /
Nanoporous material optical systems

Capacity to concentrate Integrate & analyse signals with


very low level (ppb) specificity and sensibility
of chemicals :

600m2/ of air exchange


per gram of material

ANALYSIS
PURIFICATION

Specific and definitive Direct immediate optical


capture measurement

Saturation Level Indicator 12


Granules production unit

Fully automated plant


Investment: € 2 Millions
Area: 800 m2
Capacity: 12 tons/year

13
Our customers

14
Multiple markets to grow sales A +€980M TAM
Only for Formaldehyde

16
Diagnosis Purification Monitoring 400
14 M€

12
Turnover (M€)

10

8 400
M€

2
180
M€

Adressable
0

market
2014 2015 2016 2017 2018 2019
A dynamic sales growth through an international distributor network
and industrial partnerships to leverage the development
15
A dynamic company, a +100yrs of experience’s team

Sylvain Colomb, Eng. Xavier MATHIAUD, MS


Chief Business Officer Sales Director

Thomas CARON, Eng, PhD


Experience, Value, Team Spirit, Efficacy Industrial Director

Frederic Hammel, MS, MBA


CEO

Emmanuel CHEVALLIER, PhD


Scientific Director
Karine MACQUET, MA Fahrad ABEDINI, Eng.
Admin/HR Director R&D instrumentation Director
16
Thank you
Frederic Hammel, CEO

www.ethera-labs.com
frederic.hammel@ethera-labs.com

You might also like