ATFD Condenser Tube Side Velocity

ATFD Evaporation Rate 350 Kg/hr


Operating Vacuum 100 mmhg
Operating Pressure 88 Kpa
Vapour Temprature 92 °C
Universal Gas constant, R 8.314 m3 kpa/kmol k
Vapour Temprature 92 °C
Molecular Weight of Vapour 18 Kg/kmol
Vapour Density 0.521 Kg/m3
Operating Vacuum 100 mmhg
Vapour mass Flow Rate 350 Kg/hr
Volumetric Flow Rater of Vapour 672 M3/hr

No of Tubes 250 Nos


Length of Tube 1.900 m
Tube I.D 14.5 mm
Tube C/S Area 0.0413 m2

Avg. Velocity of Vapour Tube Side 4.53 m/sec