0.3365 20,000 100 3,559.57 16.66 1,200.48 20.01 2,965.13 177.91 26,856.92
The 10" STD pipeline (ID = 254.4mm) has a total distance of 10km,
The water volume requirement to fill throughout the length was 100m 3
12"x12.7mm
14"x9.53mm
40"x9.53mm
18"
16"
12" STD
42"
3"
OIL
Pig's Speed Flowrate Pipe ID
m/hour m/min m/s BBL/Day inch
Hours km m/s
6.944 50.00 2
GAS
Production (Q) Pig's velocity Pipe ID
m3/day scfm m/s m
0.5 30"
Mimimum Require
Design
Thickness ASME B31.3 Pipe OD S (Temp) E
Pressure
Liquid
mm inch psig inch psi
Mimimum Require
Design
Thickness ASME B31.4 Pipe OD SMYS (psi) E
Pressure
Liquid
mm inch psig inch psi
inch
0 0
0 0.1
0 0.125
0.4 0
Corrosion Design
Mill Tolerance
Allowance Factor
inch Class? inch
0.125 0.5 0
Minimum
Maximum Allowable Corrosion Inspection
thickness Pipe OD
Working Pressure (MAWP) rate Inteval
found
bar psi inch inch inch/year year
psi inch
18900 1 0
ASME B31.G Original L (mm) OD (mm) t (mm) SMYS (MPa) Depth (mm) f_S f_T
BYGP SP-NP 20" 20.90 508.00 11.20 448.06 3.36 0.72 1.00
Sflow
flow stress
SF estimated failure stress level
PS
safe operating preessure
SF
safety factor
1-(2/3)*(d/t) 1-(2/3)*(d/t)/M [] P_safe ERF Log Distance Sflow
BYGP SP-NP 20" 20.00 609.60 6.35 290.00 3.36 0.72 1.00
30%
MAOP (MPa) 2*(t*f_S*f_T/D) P z = L^2/Dt M d/t 0.85(d/t) 1-0.85(d/t) 1-0.85(d/t)/M
Mpa
psi
SF ERF Hoop Stress (MPa) SMYS 72% SMYS (MPa) psi
1
145.038
ASME B31.G Modified L (mm) OD (mm) t (mm) SMYS (MPa) Depth (mm) f_S f_T
BYGP SP-NP 20" 20.90 508.00 11.20 448.06 3.36 0.72 1.00
30%
MAOP (MPa) 2*(t*f_S*f_T/D) P z = L^2/Dt M d/t 0.85(d/t) 1-0.85(d/t) 1-0.85(d/t)/M
Mpa
psi
SF ERF Hoop Stress (MPa) SMYS 50% SMYS (MPa) psi
1
145.038
UTMC
Tool Resolution
Amount of Switching
Tool Velocity Pipe OD
Axial Circum. Transducer rate
mm mm m/s unit Hz mm
inch
24.00
24.00
Mimimum Require
Design
Thickness ASME B31.3 Pipe OD S (Temp) E
Pressure
Liquid
mm inch psig inch psi
0.4 0 0
0
10"
0
16"
PTTEP S1 - UT In-Line Inspection of Oil & Gas Flowlines
Design
Flow Direction
Items Services Equipment Number Pressure Original Last
Installed Inspection
Begin End psig
7 Crude TRT-CC 10"x 2.0Km (15.87mm_thk) TRT-Cext LKU-B 2,000 2014 27 Jul 19
ID
Items Pigging Sequence
m
1 Cleaning pig 0.5909
4 UT Pig 0.5909
ID
Items Pigging Sequence
m
1 Cleaning pig 0.5399
4 UT Pig 0.5399
ID
Section Pigging Sequence
m
12" x 75 km (Kamphaengphet/Phichit) 12" Caliper & MFL Batching 0.3047
14" x 292 km (Bang Pa-in/Kamphaengphet) 14" Caliper & MFL Batching 0.3365
Total
ID
Section Pigging Sequence
Pig
L Bypass Total Volume Duration Flow rate
Velocity
m % m3 m/min minutes hours l/min m3/hr
1,800 0 494 60 30 0.50 16,463 988
Pig
L Bypass Total Volume Duration Flow rate
Velocity
m % m3 m/min minutes hours l/min m3/hr
1,800 0 412 60 30 0.50 13,744 825
Acummulative
Length Bypass Volume at Receiving Pig Velocity Duration Flow rate
end
m % m3 m/min minutes hours l/min m3/hr
75,000 0 5,472 30 2,500 41.67 2,189 131
25,985 162.22
Acummulative
Length Bypass Volume at Receiving Pig Velocity Duration Flow rate
end
m % m3 m/min minutes hours l/min m3/hr
Pressure at
wellhead ID of Pipe Specific gravity of Length of line Temp of gas
(Absolute) m gas m K
(Kpa)
Launcher
Results:
Qsc 1,563,941 sm3/d 55230.06 MMscfd
18.10 sm3/sec 38.3542070201 cfm
Reference:
Campbell gas conditioning & processing VOL1
Panhandle B equation for gas transmission lines
ing Panhandle B Eqn (No liquids in line)
Zavg E K P2
Reciever
Total Pig
ID L Bypass Duration
Items Pigging Sequence Volume Velocity
m m % m3 m/min minutes
Acummulative
Duration Flow rate Resolution (mm)
Volume
Circum
1.60
1.60
1.60
36" CRUDE LINE FOR PTT KHOABOYA
No weather-related or outside-force
Weather and outside force
issues
0.302 1,415.00
0.009 0.439
19.833 0.120
17.712 0.140
SP 20" Pipeline - Pipeline Data
Example
API 5L GR - X65
20 in. (508 mm)
0.439 in. (11.2 mm)
0.0625 in. (1.6 mm)
Seamless weld (SMLS)
TBA
TBA
TBA
TBA
None
TBA
Good
None
ent Plan for BYGP NP-SP 20" Pipeline - Integritry Assessment Plan
Interval
Integrity Assessment Mitigation
(Year)
0.307 0.009
Min_Structural thickness from API 574
0.307 0.009
Min_Alert thickness from API 574
Depth (mm) f_S f_T MAOP (MPa)2*(St*f_S*f_T/D) P z = L^2/Dt M d/t 0.85(d/t)
3.36 0.72 1.00 9.75 14.22 14.22 0.08 1.02 0.30 0.26
30%
Psafe / MAOP
Psafe / MAOP
Pfail / MAOP
0.75 0.75 0.9921076087 15.52389031 0.63 sample 492.86 488.97 21.56 15.52
###
1.59
#DIV/0!
2.21
FPR (Failure Pressure Ratio)
Mpa
psi
SF ERF Po So Hoop Stress (MPa) SMYS 50% SMYS (MPa)
Sf >= SF x So ACCEPTED
Pf >= SF x Po ACCEPTED
9.75
1414.121