The Pointing and Alignment of XMM
The Pointing and Alignment of XMM
+Z EMCH-3
EMCH-2
MM-4
RGA-2
+X
RGA-1
STR 1&2
MM-3 +Y
RFC-2
RFC-1
EPCH
OM
Figure 1. Exploded view of
the XMM spacecraft,
showing the main elements Roland Circle
of the optical system MM-2
r bulletin 100 — december 1999 bull
t2
Reconstructed
knowledge
intended
attitude
Time
t1
There are typically four requirements that are of AMA is therefore a very important performance
particular interest to the scientists (Fig. 2): parameter to allow the investigator to
accurately reconstruct the energy spectrum of
The Absolute Pointing Error (APE), defined as an X-ray source.
the angular separation between the actual
direction and the intended telescope line-of- The Absolute Pointing Drift over 16 hours
sight. The APE must be such that the image of (APD), defined as the change in the angular
the observed target will fall onto the instrument separation between the actual direction and the
detector. Since all of the instrument detectors intended direction of the telescope over the
on XMM are relatively large, being at least observation time. The APD is an indication of
~6 arcmin, in practice this requirement is not how well data from individual exposures can be
very stringent. superimposed without further processing in
order to establish an integrated image. For
The Absolute Measurement Accuracy (AMA), XMM, images are superimposed a posteriori,
defined as the angular separation between the on-board for the OM instrument and on the
actual direction and the reconstructed (a ground for RGS and EPIC, and thus the APD
posteriori) direction of the telescope. The RGS requirement is not too stringent.
instrument, and to some extent also the EPIC
instrument, uses the location of a photon event The Relative Pointing Error over 2 minutes
on the CCD relative to the observed target as (RPE), defined as the angular separation
an indication of the energy of the photon. The between the actual direction of an axis and a
reference axis, over the instrument exposure
time. The allowed magnitude of RPE is usually
Table 1. Instrument pointing requirements and goals
defined as less than half of the instrument
angular resolution, in order to ensure that the
Instrument EPIC RGS OM
exposure is not ‘blurred’ by the instrument/
APE spacecraft motion. The RPE requirement for
Req. 60 60 60 the OM is very stringent, since this instrument
Goal - - - has very high resolution in the visible/UV
spectrum, ~1 arcsec.
AMA
Req. 10 10 10
The applicable pointing requirements and goals
Goal 1 4 -
for each instrument’s line of sight in arcseconds
at 95% confidence level are shown in Table 1.
APD
Req. 45 45 45
Goal - 2 - Alignment
In the case of alignment as well, thorough
RPE negotiation with the scientists has led to the
Req. 5 5 5 definition of the relevant payload requirements,
Goal 1 (5 sec) 2 (30 sec) 0.25 (10 sec) driven by the characteristics of the XMM optical
system.
pointing and alignment
The alignment requirements for each EPIC After a first round of error-budget iterations, the
‘primary focus’ camera are expressed in terms requirement and goal type of specifications
of its maximum allowed translation and rotation were again carried forward into the subsystem
with respect to the Mirror Module focus and unit specifications, to obtain the best
position and bore-sight. Because of the long price/performance procurement.
Mirror Module focal length (7.5 m), its focal
depth, which is a measure of the sensitivity of Pointing verification
the optics to de-focussing, is of the order of The pointing verification process has been
several millimetres. Such insensitivity, based on a combination of analysis,
combined with CCD detector dimensions of simulations and direct testing of the actual
the order of several centimetres, led to performances of the most critical contributors,
maximum allowed translation and rotation namely:
requirements of the order of some millimetres
and arcminutes, respectively. – bias and noise performance measurements
of the star tracker
Somewhat more complex has been the – micro-vibration measurements of the
definition of the alignment requirements in the reaction wheels
case of the ‘secondary focus’ RGS CCD – thermal gradient test of the mirror support
cameras combined with the grating platform and of the telescope tube
assemblies, mounted on the Mirror Modules. In – telescope-tube characterisation by deflec-
order to minimise optical aberrations for this tion measurements under an imposed
‘three-body’ optical configuration, it is required temperature gradient.
that the three units involved - MM, RGA and
RFC - lie on an imaginary 6.7 m-diameter As an example, Table 2 shows the specifications
‘Rowland circle’. Consequently, a careful and actual performance of the star tracker.
apportionment of the alignment requirements
had to be established early in the programme. Calibration campaign and alignment
verification
Another important consequence of the 7.5 m An end-to-end test of the complete XMM
distance between the X-ray mirrors and the spacecraft in order to check the X-ray
CCD cameras is that related to the stability performances and the correct alignment of all
requirements imposed on the structure in- the elements is not possible due to its sheer
between, which in the case of RGS camera, for dimensions. For this reason, already before
example, must be <0.1 mm over 16 hours and the start of Phase-B, the alignment-related
<0.2 mm over 3 months. Assembly, Integration and Verification (AIV)
strategy was developed along two main
Analysis and Verification directions, with the aim of avoiding ‘late
Pointing and alignment budget surprises’ during the spacecraft alignment. It
Having defined the requirements and goals was decided to:
applicable to each instrument, an exhaustive
pointing and alignment budget was – carry out an extensive characterisation of the
established. The initial use of this budget was Mirror Modules, both in stand-alone
to make error allocations to the relevant configuration and in integrated configuration
subsystems, i.e. structure, thermal, AOCS, together with the grating assembly. Such a
instruments, AIV alignment and ground calibration campaign allowed the verification
processing. It became apparent that there are at an early stage in the programme that the
two dominating error contributors to the main parameters of the optical system were
challenging measurement accuracy (AMA) within the allocated alignment budget, i.e. the
goals: focal length and the ‘Rowland circle’ diameter
– the thermo-elastic stability between the star
trackers and the Mirror Modules and between
the latter and the focal-plane cameras, and Table 2. Star-tracker specifications and performances
– the star position-determination accuracy of
the star tracker, i.e. the bias error. Error type Requirement Measured Estimated
end-of-life begin.-of-life end-of-life
To achieve the short-term pointing stability
(RPE) goals, it is essential to reduce the Bias (2 σ, in arcsec) 3.5 1.5 1.5
following two effects as much as possible:
– the measurement noise of the star tracker Noise (1 σ, in arcsec):
– the micro-vibrations originating from subtle Magnitude 8.5 2.5 1.5 1.6
imbalances or imperfections within the Magnitude 6.5 2.5 0.3 0.3
reaction wheels.
r bulletin 100 — december 1999 bull
Table 3 Acknowledgement
The authors wish to acknowledge the team
Errors Requirement Predicted Predicted effort by all personnel in the groups involved,
in arcsec goal worst case ~90% of obs. i.e. the Dornier team, the teams at Centre
Spatial de Liège, and at the MPE-Panter facility
AMA 10 5 in Garching and the ESTEC metrology group.
for RGS 4 3.1 They are to be congratulated on their success
in the timely and accurate design, implementation
RPE 5 1 and determination of the optical performance of
for OM 0.25 0.33 the XMM telescope. r
pointing and alignment