Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Technical

specification

Submersible pump C 3152, 50 Hz


C 3152

7G4+2x1,5 mm2
7G6+2x1,5 mm2

Monitoring equipment
Thermal contacts opening temperature 125 °C

Material
Impeller Cast iron
Pump housing Cast iron
Stator housing Cast iron
Shaft Stainless steel
O-rings Nitrile rubber
Mechanical face seals

Alternative Inner seal Outer seal


1 Corrosion resistant Corrosion resistant
cemented carbide/ cemented carbide/
Carbon Corrosion resistant
cemented carbide
2 Corrosion resistant Corrosion resistant
cemented carbide/ cemented carbide/

C 3152
Corrosion resistant Corrosion resistant
cemented carbide cemented carbide

Surface Treatment
All cast parts are primed with a water-borne primer. The finishing coat
Product is a high-solid two pack paint.
Submersible pump for pumping clean water, surface water and waste
water containing solids or long-fibred material. Weight
See dimensional drawing.
Denomination
Product code 3152.181 Option
Installation P, S, T, Z 3152.091 Ex. proof design
Impeller characteristics LT, MT, HT, SH Warm liquid version on request
Leakage sensor in stator housing FLS
Process data Leakage sensor in oil housing CLS
Liquid temperature max +40 °C Surface treatment Epoxy treatment
Depth of immersion max 20 m Other cables
The pH of the pumped liquid pH 5,5-14 Zinc anodes
Liquid density max. 1100 kg/m3
Impeller throughlet See Motor rating table Accessories
Discharge connections, adapters, hose connections and other
Motor data mechanical accessories.
Frequency 50 Hz Electrical accessories such as pump controller, control panels, starters,
monitoring relays, cables.
Insulation class H (+180 °C)
See separate booklet for further information.
Voltage variation
- continuously running max ± 5%
- intermittent running max ± 10%
Voltage imbalance between phases max 2%
No. of starts/hour max 30

Cable
Direct-on-line start
SUBCAB® 4G4+2x1,5 mm2
4G6+2x1,5 mm2
4G10+2x1,5 mm2
Y/D start
SUBCAB® 7G2,5+2x1,5 mm2

2
C 3152

LT-Motor rating and performance


curve P2 [kW]

Ex proof version available


10
Impeller thoughlet, mm
Power factor cos ϕ
Starting current, A
Curve/Impeller No

8
Rated power, kW

Rated current, A

616
6 620
618

624 622

H [m]
Installation
P S T Z LT
9
400 V, 50 Hz, 3 ~, 955 r/min
616 8,8 18 87 0,87 102 • • • • • 8
618 8,8 18 87 0,87 102 • • • • • 7
620 8,8 18 87 0,87 102 • • • • •
6
622 8,8 18 87 0,87 102 • • • • •
624 8,8 18 87 0,87 102 • • • • • 5
230 V, 50 Hz, 3 ~, 955 r/min
4
616 8,8 31 156 0,86 102 • • • • •
618 8,8 31 156 0,86 102 • • • • • 3
620 8,8 31 156 0,86 102 • • • • • 2
622 8,8 31 156 0,86 102 • • • • •
1 620 618
616
624 8,8 31 156 0,86 102 • • • • • 624 622

Y/D starting current is approximately 1/3 of D starting current.


0
0 50 100 150 200 250
Q [l/s]

3
C 3152

MT-Motor rating and performance


curve P2 [kW]

Ex proof version available


14

Impeller thoughlet, mm
12
430
Power factor cos ϕ
Starting current, A

431
Curve/Impeller No

10
Rated power, kW

Rated current, A

8 432

6 434
436

H [m]
Installation
P S T Z MT
400 V, 50 Hz, 3 ~, 1455 r/min
25
432 9,0 19 116 0,81 100 • • • • •
434 9,0 19 116 0,81 100 • • • • •
436 9,0 19 116 0,81 93 • • • • • 20

400 V, 50 Hz, 3 ~, 1450 r/min


430 13,5 27 162 0,83 100 • • • • • 15
431 13,5 27 162 0,83 100 • • • • •
432 13,5 27 162 0,83 100 • • • • •
10
434 13,5 27 162 0,83 100 • • • • •
436 13,5 27 162 0,83 93 • • • • •
430
230 V, 50 Hz, 3 ~, 1455 r/min 5
432 431
434
432 9,0 33 198 0,81 100 • • • • • 436

434 9,0 33 198 0,81 100 • • • • • 0


436 9,0 33 198 0,81 93 • • • • • 0 20 40 60 80 100
Q [l/s]
230 V, 50 Hz, 3 ~, 1450 r/min
430 13,5 77 270 0,84 100 • • • • •
431 13,5 77 270 0,84 100 • • • • •
432 13,5 77 270 0,84 100 • • • • •
434 13,5 77 270 0,84 100 • • • • •
436 13,5 77 270 0,84 93 • • • • •

Y/D starting current is approximately 1/3 of D starting current.

4
C 3152

HT-Motor rating and performance


P2 [kW]
curve
14 450

Ex proof version available


452
12
Impeller thoughlet, mm 10
Power factor cos ϕ
Starting current, A
Curve/Impeller No

Rated power, kW

454
Rated current, A

8
6

H [m]
Installation
HT
P S T Z
30
400 V, 50 Hz, 3 ~, 1455 r/min
454 9,0 19 116 0,81 76 • • • • •
25
400 V, 50 Hz, 3 ~, 1450 r/min 450
450 13,5 27 162 0,83 76 • • • • •
20
452 13,5 27 162 0,83 76 • • • • •
454 13,5 27 162 0,83 76 • • • • •
15
230 V, 50 Hz, 3 ~, 1455 r/min
454 9,0 33 198 0,81 76 • • • • •
10
230V, 50 Hz, 3 ~, 1450 r/min 452
450 13,5 47 270 0,84 76 • • • • • 454
5
452 13,5 47 270 0,84 76 • • • • •
454 13,5 47 270 0,84 76 • • • • •
0
Y/D starting current is approximately 1/3 of D starting current. 0 10 20 30 40 50 60 70
Q [l/s]

SH-Motor rating and performance


curve
Ex proof version available
Impeller thoughlet, mm

P2 [kW]
Power factor cos ϕ
Starting current, A
Curve/Impeller No

Rated power, kW

Rated current, A

20

263 264
15 265
266
267
10 268
Installation 269

P S T Z
400 V, 50 Hz, 3 ~, 2920 r/min H [m]
263 15 28 229 0,89 40 • • • • •
263 SH
264 15 28 229 0,89 40 • • • • •
60
265 15 28 229 0,89 40 • • • • •
266 15 28 229 0,89 40 • • • • • 264
50
267 15 28 229 0,89 40 • • • • •
268 15 28 229 0,89 40 • • • • •
40
269 15 28 229 0,89 40 • • • • •
230 V, 50 Hz, 3 ~, 2915 r/min 265
30
263 15 47 375 0,90 40 • • • • • 266

264 15 47 375 0,90 40 • • • • • 267


20
265 15 47 375 0,90 40 • • • • • 268

266 15 47 375 0,90 40 • • • • • 269


10
267 15 47 375 0,90 40 • • • • •
268 15 47 375 0,90 40 • • • • •
0
269 15 47 375 0,90 40 • • • • •
0 5 10 15 20 25
Q [l/s]
Y/D starting current is approximately 1/3 of D starting current.

5
C 3152

Dimensional drawing
All drawings are available as Acrobat documents (.pdf)
and AutoCad drawings (.dwg). Download the drawings
from www.xyleminc.com or contact your Xylem represent-
ative for more information.
All dimensions are in mm.
LT, P-installation LT, P-installation

6
C 3152

LT, S-installation LT, T-installation

HT, T-installation MT, P-installation

7
C 3152

MT, P-installation MT, S-installation

MT, S-installation MT, T-installation

8
C 3152

HT-SH, T-installation HT, P-installation

HT-SH, P-installation HT-SH, S-installation

9
C 3152

HT, S-installation HT, S-installation

10
Xylem |’zīləm|
1) The tissue in plants that brings water upward from the roots
2) A leading global water technology company

We're 12,000 people unified in a common purpose: creating


innovative solutions to meet our world's water needs. Developing new
technologies that will improve the way water is used, conserved, and
re-used in the future is central to our work. We move, treat, analyze,
and return water to the environment, and we help people use water
efficiently, in their homes, buildings, factories and farms. In more than
150 countries, we have strong, long-standing relationships with
customers who know us for our powerful combination of leading
product brands and applications expertise, backed by a legacy of
innovation.

For more information on how Xylem can help you, go to xyleminc.com

Xylem Water Solutions AB Visit our Web site for the latest version of this document and
more information
Gesällvägen 33
174 87 Sundbyberg The original instruction is in English. All non-English
instructions are translations of the original instruction.
Sweden
Tel. +46-8-475 60 00 © 2011 Xylem Inc

Fax +46-8-475 69 00
http://tpi.xyleminc.com

895238_2.1_en.GB_2012-06_TS_C3152_50Hz

You might also like