6” Pressure Gauges (Panel Mount Style)


2000B Pressure Gauge……………………………………………………16
2400 Pressure Gauge……………………………………………………...19
6” Pressure Gauges (All-in-One Style)
M100 Pressure Gauge……………………………………………………..22
2000P Pressure Gauge.………………………………...…………………..25
4-20mA Transmitters
2021 Pressure Transmitter..………………………………………………...28
Pump Stroke Counters
2100 Pump Stroke Counter………………………………………………..30
Choke Position Indicators
2200 Choke Position Indicator……………………………………………..32
2522 Choke Position Indicator……………………………………………..35
Valve Position Indicator
2250 Valve Position Indicator………………………………….(coming soon)
Mud Gas Separator Monitoring
3200 Mud Gas Differential Monitoring System……………….(coming soon)
6” Temperature Gauges (Panel Mount Style)
3300 Temperature Gauge……………………………………...(coming soon)
Choke Control Console
9000 Choke Console…………………………………………………...….38

Service Plans….………………………………………………………………….45

3 of 74 Version 17.2.0
Table of Contents

Data Sheets……………………………………………………………………...49

M100 Pressure Gauge……………………………………………………50


2000B Pressure Gauge…………………………………………………...52
2000P Pressure Gauge…………………………………………………...54
2021 Pressure Transmitter……………………………………………….56
2100 Pump Stroke Counter……………………………………………...58
2200 Choke Position Indicator…………………………………………..60
2250 Valve Position Indicator…………………………………………….62
2400 Pressure Gauge…………………………………………………….64
2522 Choke Position Indicator…………………………………………..66
3200 Mud Gas Differential Monitoring System………………………….68
3300 Temperature Gauge………………………………………………...70

International - Authorized Agents………………………………………...….…72


Contact Information…………………………………………………….….…...74

4 of 74 Version 17.2.0
Company Overview

In the early 1990s, HDI Instruments, LLC was encouraged by leading oil and gas operators to
develop a safe, accurate replacement for the inaccurate, hydraulic pressure gauges seen through-
out the industry. By 1991, HDI had successfully field proven the HDI 2000, a 6” Panel Gauge.
Its successor, the HDI 2000B, is used heavily in offshore well control applications by leading in-
ternational oil and gas operators and drilling contractors.

Today, HDI continues to be an industry leader in providing certified, intrinsically safe, and accu-
rate instrumentation for oil and gas applications worldwide. Our various types of instruments
are industry leading control and monitoring systems for high pressure, high temperature applica-
tions. Over the past 25 years, HDI has developed and continues to improve upon a suite of
products focused on surface monitoring which include: Pressure Gauges, Pressure Transmitters,
Pump Stroke Counters, Choke Position Indicators, and more.

Safety is critical to HDI’s success. Compared with the industry alternatives, HDI’s product line
enhances safety by providing more accurate and reliable instrumentation that is critical during
operations. With proper service, HDI’s instrumentation will give the user less downtime and
greater accuracy than industry alternatives.

HDI’s Products Support Industry Leaders

5 of 74 Version 17.2.0
Applications

Acidizing

BOP Testing

Cementing

Coil Tubing

Drilling

Fracking

Misc. Pumping

Production

Hazardous Areas and Compliance

- CSA and ATEX Certifications


Available

- API 6A, 16C Compliant

- IP Ratings

6 of 74 Version 17.2.0
7 of 74 Version 17.2.0
Battery Powered Instrumentation

Models:
 M100 Pressure Gauge
 2000B Pressure Gauge
 2000P Pressure Gauge
 2100 Pump Stroke Counter
 2200 Choke Position Indicator
 2400 Pressure Gauge
 2500 Choke Position Indicator
 3300 Temperature Gauge
 9000 Choke Console

Features:
 Retrofits existing instrumentation
 Certified systems by CSA and ATEX for Class 1, Div 1 Hazardous Envi-
ronments
 Prevents high pressure and high temperature signal loss during critical rig
power outages; independently powered system; over 18 month battery
life with continued use
 Long life span on system components due to consistent current draw
from battery

8 of 74 Version 17.2.0
Rig Powered Instrumentation

Models:
 2021 Pressure Transmitter
 2250 Valve Position Indicator
 3200 Mud Gas Differential Monitoring System
 V9000 Virtual Choke Console

Features:
 Retrofits existing instrumentation
 Certified systems by CSA and ATEX for Class 1, Div 1 Hazardous Envi-
ronments
 4-20mA output signal for simple integration into drilling, monitoring, and
measurement systems

9 of 74 Version 17.2.0
System Overview

1 of 74 Version 17.2.0
2 of 74
The System Overview seen on the next page summarizes the battery power versus rig power distinction when
it comes to HDI’s products. There are two main options to achieve a battery powered system while providing 4
-20mA signals to a remote display in the Driller’s Cabin. During operations, rig crews should always be able to
read their pressures accurately from a distance, regardless of other operations onboard.

HDI’s battery powered instruments (shown in green) will continue to operate independently from any other
system, and will accurately give the user feedback when other systems may not be working. Transmitters and
other 4-20mA sensors (shown in red) require rig power at all times to operate leaving the sensors vulnerable
during unexpected losses in rig power.

HDI offers both battery powered and rig powered solutions, but recommends the battery power design be
strongly considered as a primary back up system as it gives the user a secondary display that is more accurate
and durable than industry alternatives, namely hydraulic pressure gauges.

Version 17.2.0
12 of 74 Version 17.2.0
13 of 74 Version 17.2.0
Product Configurators

14 of 74 Version 17.2.0
15 of 74 Version 17.2.0
2000B PRESSURE GAUGE VERSION 17.1

SPECIFICATIONS
Pressure Range: 10k
Sensor Connection: 1502 Hammer Union
Certification: CSA
Configuration: No Output

ACCESSORIES
Flange/Adapter: See Sections 3 and 4
Slave Gauge: See Section 6
Cable: See Section 7

1. PRESSURE RANGE (SELECT ONE)

30PSI 100PSI 300PSI 1KPSI 3KPSI 6KPSI 10KPSI 16KPSI

2. SENSOR CONNECTION (SELECT ONE)

2” 1502 Hammer Union


( Standard )
1” NPT

2” 1502 H2S Hammer Union

9/16” Autoclave Sensor


2” 2202 H2S Hammer Union Note: Only Compatible with
HDI Autoclave Flanges

3. AUTOCLAVE FLANGES (MUST SELECT 9/16” AUTOCLAVE SENSOR)

Specify Pressure Rating and Size

Pressure Rating: 5M 10M 15M

Size: 1 13/16 ” 2 1/16 ”

4130 Directors Row, Houston, TX 77092 | 713-688-8555

16 of 74 Version 17.2.0
2000B PRESSURE GAUGE VERSION 17.1

4. CROSS OVER FLANGES/WYE ADAPTERS (MUST SELECT 1502 OR 2202 HAMMER UNION SENSOR)

For Cross Over Flange: Specify Pressure Rating, Size, and Connection Type

For Wye Adapter: Specify Connection Type

Pressure Rating: 5M 10M 15M

Size: 1 13/16 ” 2 1/16 ”

Connection Type: 1502 2202


Cross Over Flange Wye Adapter

5. CONFIGURATION (SELECT ONE) 6. SLAVE GAUGE (MUST SELECT SLAVE OUTPUT)

No Output ( Standard ) Slave Gauge w/ No Output

4-20mA Output Slave Gauge w/ 4-20mA Output

Slave Output ATEX Slave Gauge w/ No Output

ATEX Slave Gauge w/ 4-20mA Output

7. CABLE

The 2000B Pressure Gauge System does not include any cable. Inline Cable is required for new orders; clients with
existing Inline Cable may use the existing cable with a new 2000B Pressure Gauge System. 4-20mA Cable and
Slave Cable are only used if the 4-20mA Output or Slave Output Configuration was selected in Section 5. Cable is
purchased in 5’ increments.

Inline Cable: Distance from Pressure Transducer (Sensor) to 2000B Gauge Display

4-20mA Output Cable: Distance from 2000B Gauge Display to Local J-Box Termination

Slave Cable: Distance from 2000B Gauge (Master) Display to 2000B Slave Display

8. CERTIFICATION

CSA: Intrinsically Safe Class 1, Division 1, Groups A, B, C, and D ( Standard )

ATEX: optional, II 1 G, Ex ia IIC T4

4130 Directors Row, Houston, TX 77092 | 713-688-8555

17 of 74 Version 17.2.0
2000B PRESSURE GAUGE VERSION 17.1

APPENDIX A: REPLACEMENT SYSTEMS AND PARTS

Full Replacement 2000B Gauge Display

Specify Pressure Range, Configuration (Output), and Certification. Must be calibrated with existing HDI 2000B Sensor.

Full Replacement 2000B Sensor (Transducer)

Specify Pressure Range, Sensor Connection, and Certification. Must be calibrated with existing 2000B Gauge Display.

Part Number Description


HDIBATTE260DOTAA Micro P Power Pack, include MSDS Class IX UN 3090 or 3091

The enclosed adaptor is used to convert older “E391” batteries to use the common E260.
HDIBATTE260ADPTR
If the HDI 202 PCB is newer style, this may not be required. No charge

FAB2000M993 1502 Diaphragm

FAB2000-M1124 2202 Diaphragm

HDI201AC01106HD 6K PSI LCD Assembly HDI 201 PCB

HDI201AC01210HD 10K PSI LCD Assembly HDI 201 PCB

HDI201AC01316HD 16K PSI LCD Assembly HDI 201 PCB

HDI202AB005STD-06 HDI 202 2KB Processor Board Assy Standard 6K Preloaded Software

HDI202AB005STD-10 HDI 202 2KB Processor Board Assy Standard 10K Preloaded Software

HDI202AB005STD16 HDI 202 2KB Processor Board Assy Standard 16K Preloaded Software

HDI202A-B005-420-06 HDI 202 2KB Processor Board Assy Standard 6K Preloaded Software 4-20mA Output

HDI202A-B005-420-10 HDI 202 2KB Processor Board Assy Standard 10K Preloaded Software 4-20mA Output

HDI202A-B005-420-16 HDI 202 2KB Processor Board Assy Standard 16K Preloaded Software 4-20mA Output

HDI202AB005-SLV-06 HDI 202 2KB Processor Board Assy Standard 6K Preloaded Software Slave Output

HDI202AB005-SLV-10 HDI 202 2KB Processor Board Assy Standard 10K Preloaded Software Slave Output

HDI202AB005-SLV-16 HDI 202 2KB Processor Board Assy Standard 16K Preloaded Software Slave Output

HDI20000600STDAA 600 Bar Pill And Temp Comp Board Assy For 6K or 10K PSI Pressure Gauge Sensors

HDI20001000STDAA 1000 Bar Pill And Temp Comp Board Assy For 10K or 16K PSI Pressure Sensors

6-32 Screws, Standoffs, Corrosion Inhibitor, Desi Pack, Humidity Indicator,


KIT2000103RPRKT
Outer Seal Gasket and Protective Lense
Pill Replacement Kit: Includes Pill Rubber Diaphragm, Snap Ring, Rubber
KIT2000104SNSRR Grommet for Kellum’s Grip Design (Wire Mesh, Post 2009), Rubber
Grommet for M983 Design (No Wire Mesh, Pre 2009), and Pill Insertion Tool

4130 Directors Row, Houston, TX 77092 | 713-688-8555

18 of 74 Version 17.2.0
2400 PRESSURE GAUGE VERSION 17.1

SPECIFICATIONS
Pressure Range: 10k
Sensor Connection: 1502 Hammer Union
Certification: CSA
Configuration: No Output
Alarm Kickoff: Sourcing

ACCESSORIES
Flange/Adapter: See Sections 3 and 4
Slave Gauge: See Section 6
Cable: See Section 7

1. PRESSURE RANGE (SELECT ONE)

6KPSI 10KPSI 16KPSI

2. SENSOR CONNECTION (SELECT ONE)

2” 1502 Hammer Union 9/16” Autoclave Sensor


( Standard )
Note: Only Compatible with
2” 1502 H2S Hammer Union HDI Autoclave Flanges

2” 2202 H2S Hammer Union

3. AUTOCLAVE FLANGES (MUST SELECT 9/16” AUTOCLAVE SENSOR)

Specify Pressure Rating and Size

Pressure Rating: 5M 10M 15M

Size: 1 13/16 ” 2 1/16 ”

4130 Directors Row, Houston, TX 77092 | 713-688-8555

19 of 74 Version 17.2.0
2400 PRESSURE GAUGE VERSION 17.1

4. CROSS OVER FLANGES/WYE ADAPTERS (MUST SELECT 1502 OR 2202 HAMMER UNION SENSOR)

For Cross Over Flange: Specify Pressure Rating, Size, and Connection Type

For Wye Adapter: Specify Connection Type

Pressure Rating: 5M 10M 15M

Size: 1 13/16 ” 2 1/16 ”

Connection Type: 1502 2202


Cross Over Flange Wye Adapter

5. CONFIGURATION (SELECT ONE) 6. ALARM KICKOUT

No Output ( Standard ) Sourcing

4-20mA Output Syncing

Dry Contact

If Alarm kickout is not needed, see 2000B Pressure Gauge

7. CABLE

The 2400 Pressure Gauge System does not include any cable. Inline Cable is required for new orders; clients with
existing Inline Cable may use the existing cable with a new 2400 Pressure Gauge System. 4-20mA output cable is only
used if the 4-20mA Output was selected in Section 5. Cable is purchased in 5’ increments.

Inline Cable: Distance from Pressure Transducer (Sensor) to 2400 Gauge Display

4-20mA Output Cable: Distance from 2400 Gauge Display to Local J-Box Termination

Alarm Cable: Distance from 2400 Gauge Display to Local J-Box Termination

8. CERTIFICATION

CSA: Intrinsically Safe Class 1, Division 1, Groups A, B, C, and D ( Standard )

ATEX: optional, II 1 G, Ex ia IIC T4

4130 Directors Row, Houston, TX 77092 | 713-688-8555

20 of 74 Version 17.2.0
2400 PRESSURE GAUGE VERSION 17.1

APPENDIX A: REPLACEMENT SYSTEMS AND PARTS

Full Replacement 2400 Gauge Display

Specify Pressure Range, Configuration (Output), Alarm Kickout, and Certification. Must be calibrated with existing HDI 2400

Sensor.

Full Replacement 2400 Sensor (Transducer)

Specify Pressure Range, Sensor Connection, and Certification. Must be calibrated with existing 2400 Gauge Display.

Part Number Description


HDIBATTE260DOTAA Micro P Power Pack, Include MSDS Class IX UN 3090 or 3091

HDI001DS272DISAD HDI 001 LCD Assy - HDI 2400

HDI002DS273DIG06 HDI 002 Digital PCB Assy - Preloaded w/ 6K PSI Software

HDI002DS273DIG10 HDI 002 Digital PCB Assy - Preloaded w/ 10K PSI Software

HDI002DS273DIG16 HDI 002 Digital PCB Assy - Preloaded w/ 16K PSI Software

HDI003DS274ANAAD HDI 003 Analog PCB Assy

FAB2400M376FGBAA 4BTN Piezo Front Panel Assy

HDI104ALARMPCB HDI 104 Alarm PCB Assy

KIT24000103RPRKT Hardware Kit HDI 2400 Needed When Replacing PCB Boards Only

KIT24000103HRWKT Gauge Hardware Repair Kit: Screws, Desi Pack, Inhibitor, ETC

4130 Directors Row, Houston, TX 77092 | 713-688-8555

21 of 74 Version 17.2.0
M100 PRESSURE GAUGE Version 17.1

SPECIFICATIONS
Pressure Range: 10k
Sensor Connection: 1502 Hammer Union
Certification: None, See 2000P Pressure Gauge
Configuration: No Output

ACCESSORIES
Adapter: See Section 3
Slave Gauge: See Section 6
Cable: See Section 7

1. PRESSURE RANGE (SELECT ONE)

6KPSI 10KPSI 16KPSI

2. SENSOR CONNECTION (SELECT ONE)

2” 1502 Hammer Union ( Standard )


2” 2202 H2S Hammer Union
2” 1502 H2S Hammer Union

Flange Sensor
Specify Pressure Rating and Size

Pressure Rating: 5M 10M 15M





Size: 1 /16 ”
13
2 1/16 ”

4130 Directors Row, Houston, TX 77092 | 713-688-8555

22 of 74 Version 17.2.0
M100 PRESSURE GAUGE Version 17.1

3. CROSS OVER FLANGES/WYE ADAPTERS (MUST SELECT 1502 OR 2202 HAMMER UNION SENSOR)

For Cross Over Flange: Specify Pressure Rating, Size, and Connection Type

For Wye Adapter: Specify Connection Type

Pressure Rating: 5M 10M 15M

Size: 1 13/16 ” 2 1/16 ”

Connection Type: 1502 2202


Cross Over Flange Wye Adapter

4. CONFIGURATION (SELECT ONE) 5. SLAVE GAUGE (MUST SELECT SLAVE OUTPUT)

No Output ( Standard ) Slave Gauge w/ No Output

4-20mA Output Slave Gauge w/ 4-20mA Output

Slave Output

Backlight

6. CABLE

The M100 Pressure Gauge System does not include any cable. 4-20mA Cable, Slave Cable, and Backlight Cable
are only used if the 4-20mA Output, Slave Output, or Backlight Configuration was selected in Section 4. Cable is
purchased in 5’ increments.

4-20mA Output Cable: Distance from M100 Gauge Display to Local J-Box Termination

Slave Cable: Distance from M100 Gauge (Master) Display to 2000B Slave Display

Backlight Cable: Distance from M100 Gauge Display to Local J-Box Termination

7. CERTIFICATION

None, See 2000P Pressure Gauge

4130 Directors Row, Houston, TX 77092 | 713-688-8555

23 of 74 Version 17.2.0
M100 PRESSURE GAUGE Version 17.1

APPENDIX A: REPLACEMENT SYSTEMS AND PARTS

Part Number Description


HDIM100BATT001 HDI M100 Standard 1 Year Power Pack, include MSDS Class XI UN 3090 or 3091

FAB2000M993 1502 Diaphragm

FAB2000-M1124 2202 Diaphragm

4130 Directors Row, Houston, TX 77092 | 713-688-8555

24 of 74 Version 17.2.0
2000P PRESSURE GAUGE Version 17.1

SPECIFICATIONS
Pressure Range: 10k
Sensor Connection: 1502 Hammer Union
Certification: CSA
Configuration: No Output

ACCESSORIES
Adapter: See Section 3
Slave Gauge: See Section 5
Cable: See Section 6

1. PRESSURE RANGE (SELECT ONE)

6KPSI 10KPSI 16KPSI

2. SENSOR CONNECTION (SELECT ONE)

2” 1502 Hammer Union ( Standard )


2” 2202 H2S Hammer Union
2” 1502 H2S Hammer Union

Flange Sensor
Specify Pressure Rating and Size

Pressure Rating: 5M 10M 15M





Size: 1 /16 ”
13
2 1/16 ”

4130 Directors Row, Houston, TX 77092 | 713-688-8555

25 of 74 Version 17.2.0
2000P PRESSURE GAUGE Version 17.1

3. CROSS OVER FLANGES/WYE ADAPTERS (MUST SELECT 1502 OR 2202 HAMMER UNION SENSOR)

For Cross Over Flange: Specify Pressure Rating, Size, and Connection Type

For Wye Adapter: Specify Connection Type

Pressure Rating: 5M 10M 15M

Size: 1 13/16 ” 2 1/16 ”

Connection Type: 1502 2202


Cross Over Flange Wye Adapter

4. CONFIGURATION (SELECT ONE) 5. SLAVE GAUGE (MUST SELECT SLAVE OUTPUT)

No Output ( Standard ) Slave Gauge w/ No Output

Slave Output Slave Gauge w/ 4-20mA Output

6. CABLE

The 2000P Pressure Gauge System does not include any cable. Slave Cable is only used if the Slave Output
Configuration was selected in Section 4. Cable is purchased in 5’ increments.

Slave Cable: Distance from 2000P Gauge (Master) Display to 2000B Slave Display

7. CERTIFICATION

CSA: Intrinsically Safe Class 1, Division 1, Groups A, B, C, and D ( Standard )

4130 Directors Row, Houston, TX 77092 | 713-688-8555

26 of 74 Version 17.2.0
2000P PRESSURE GAUGE Version 17.1

APPENDIX A: REPLACEMENT SYSTEMS AND PARTS

Part Number Description


HDIBATTE260D0TAA Micro P Power Pack, include MSDS Class IX UN 3090 or 3091

FAB2000M993 1502 Diaphragm

FAB2000-M1124 2202 Diaphragm

4130 Directors Row, Houston, TX 77092 | 713-688-8555

27 of 74 Version 17.2.0
2021 PRESSURE TRANSMITTER VERSION 17.1

SPECIFICATIONS
Pressure Range: 10k
Sensor Connection: 1502 Hammer Union
Certification: CSA

ACCESSORIES
Flange/Adapter: See Sections 3 and 4
Cable: See Section 5

1. PRESSURE RANGE (SELECT ONE)

6KPSI 10KPSI 16KPSI

2. SENSOR CONNECTION (SELECT ONE)

2” 1502 Hammer Union 9/16” Autoclave Sensor


( Standard )
Note: Only Compatible with
HDI Autoclave Flanges
2” 1502 H2S Hammer Union

2” 2202 H2S Hammer Union

3. AUTOCLAVE FLANGES (MUST SELECT 9/16” AUTOCLAVE SENSOR)

Specify Pressure Rating and Size

Pressure Rating: 5M 10M 15M

Size: 1 13/16 ” 2 1/16 ”

4130 Directors Row, Houston, TX 77092 | 713-688-8555

28 of 74 Version 17.2.0
2021 PRESSURE TRANSMITTER VERSION 17.1

4. CROSS OVER FLANGES/WYE ADAPTERS (MUST SELECT 1502 OR 2202 HAMMER UNION SENSOR)

For Cross Over Flange: Specify Pressure Rating, Size, and Connection Type

For Wye Adapter: Specify Connection Type

Pressure Rating: 5M 10M 15M

Size: 1 13/16 ” 2 1/16 ”

Connection Type: 1502 2202


Cross Over Flange Wye Adapter

5. CABLE

The 2021 Pressure Transmitter System does not include any cable. 4-20mA Output Cable is required for new orders;
clients with existing 4-20mA Output Cable may use the existing cable with a new 2021 Pressure Transmitter System.
Cable is purchased in 5’ increments.

4-20mA Output Cable: Distance from 2021 Pressure Transmitter to Local J-Box Termination

6. CERTIFICATION

CSA: Intrinsically Safe Class 1, Division 1, Groups A, B, C, and D ( Standard )

ATEX: optional, II 1 G, Ex ia IIC T4

APPENDIX A: REPLACEMENT PARTS

Part Number Description


HDI20000600STDAA 600 Bar Pill And Temp Comp Board Assy For 6K or 10K PSI Pressure Gauge Sensors

HDI20001000STDAA 1000 Bar Pill And Temp Comp Board Assy For 10K or 16K PSI Pressure Sensors

Pill Replacement Kit: Includes Pill Rubber Diaphragm, Snap Ring, Rubber Grommet for
KIT2000104SNSRR Kellum’s Grip Design (Wire Mesh, Post 2009), Rubber Grommet for M983 Design
(No Wire Mesh, Pre 2009), and Pill Insertion Tool

4130 Directors Row, Houston, TX 77092 | 713-688-8555

29 of 74 Version 17.2.0
2100 PUMP STROKE COUNTER VERSION 17.1

SPECIFICATIONS
Number of Pumps: 3
Sensor Connection: Proximity
Certification: CSA

ACCESSORIES
Cable: See Section 3

1. NUMBER OF PUMPS (SELECT ONE)

1 2 3 4

2. SENSOR CONNECTION (SELECT ONE)

Proximity (Standard) Micro-Switch

Dual Proximity (4-20mA) Dual Micro-Switch (4-20mA)

3. CABLE

The 2100 Pump Stroke Counter Systems includes cable. Cable is required for new orders; clients with existing cable
may use the existing cable with a new 2100 Pump Stroke Counter System. Two cable lengths are required, main cable
and leg cable.

Main Cable: Distance from 2100 Gauge Display to Junction Box/Y-Split

Leg Cable: Distance from Junction Box/Y-split to Pumps

4. CERTIFICATION

CSA: Intrinsically Safe Class 1, Division 1, Groups A, B, C, and D ( Standard )

ATEX: optional, II 1 G, Ex ia IIC T4

4130 Directors Row, Houston, TX 77092 | 713-688-8555

30 of 74 Version 17.2.0
2100 PUMP STROKE COUNTER VERSION 17.1

APPENDIX A: REPLACEMENT SYSTEMS AND PARTS

Full Replacement 2100 Gauge Display

Specify Number of Pumps and Certification. Must be calibrated with existing HDI 2100 Sensor.

Full Replacement 2100 Sensor (Transducer)

Specify Sensor Connection and Certification. Must be calibrated with existing 2100 Gauge Display.

Part Number Description


HDIBATTE260DOTAA Micro P Power Pack, Include MSDS Class IX UN 3090 or 3091

HDI012DPS0COMPL HDI 012 Processor Board Assy-

FAB2100M485PNLAA PSC Piezo Panel 4BTN

KIT21000103RPRKT PSC Repair Hardware Kit: Desi Pack, Corrison Inhibitor, Humidity Indicator and Screws

4130 Directors Row, Houston, TX 77092 | 713-688-8555

31 of 74 Version 17.2.0
2200 CHOKE POSITION INDICATOR VERSION 17.1

SPECIFICATIONS
Sensor Connection: Linear Pontentiometer
Certification: CSA
Configuration: No Output

ACCESSORIES
Cable: See Section 3

1. SENSOR CONNECTION (SELECT ONE)

Retractable Potentiometer
Linear Potentiometer
(Standard)
Dual Retractable
Potentiometer (4-20mA)
Dual Linear Potentiometer
(4-20mA)

Rotary (M3D) Potentiometer

Rotary (Swaco)
Potentiometer

2. CONFIGURATION (SELECT ONE)

No Output ( Standard )

4-20mA Output

4130 Directors Row, Houston, TX 77092 | 713-688-8555

32 of 74 Version 17.2.0
2200 CHOKE POSITION INDICATOR VERSION 17.1

3. CABLE

The 2200 Choke Position Indicator System does not include any cable. Inline Cable is required for new orders; clients
with existing Inline Cable may use the existing cable with a new 2200 Choke Position Indicator System. 4-20mA Cable
is only used if the 4-20mA Output Configuration was selected in Section 2. Cable is purchased in 5’ increments.

Inline Cable: Distance from Sensor to 2200 Gauge Display

4-20mA Output Cable: Distance from 2200 Gauge Display to Local J-Box Termination

4. CERTIFICATION

CSA: Intrinsically Safe Class 1, Division 1, Groups A, B, C, and D ( Standard )

ATEX: optional, II 1 G, Ex ia IIC T4

4130 Directors Row, Houston, TX 77092 | 713-688-8555

33 of 74 Version 17.2.0
2200 CHOKE POSITION INDICATOR VERSION 17.1

APPENDIX A: REPLACEMENT SYSTEMS AND PARTS

Full Replacement 2200 Gauge Display

Specify Configuration (Output) and Certification. Must be calibrated with existing HDI 2200 Sensor.

Full Replacement 2200 Sensor (Transducer)

Specify Sensor Connection and Certification. Must be calibrated with existing 2200 Gauge Display.

Part Number Description


HDIBATTE260DOTAA Micro P Power Pack, Include MSDS Class IX UN 3090 or 3091

HDI013BS515MEMAA HDI 013 Membrane PCP Assembly

HDI016A0420PCBAA HDI 016 4-20MA PCB Assy

HDI2200M901MEMAA HDI 2200 Membrane Panel

KIT22000103RPRKT CPI Hardware Kit: Desi Pack, Corrison Inhibitor, Humidity Indicator and Screws

4130 Directors Row, Houston, TX 77092 | 713-688-8555

34 of 74 Version 17.2.0
2522 CHOKE POSITION INDICATOR VERSION 17.1

SPECIFICATIONS
Sensor Connection: Linear Pontentiometer
Certification: None, See 2200 Choke Position Indicator
Configuration: No Output

ACCESSORIES
Cable: See Section 3

1. SENSOR CONNECTION (SELECT ONE)

Retractable Potentiometer
Linear Potentiometer
(Standard)
Dual Retractable
Potentiometer (4-20mA)
Dual Linear Potentiometer
(4-20mA)

Rotary (M3D) Potentiometer

Rotary (Swaco)
Potentiometer

2. CONFIGURATION (SELECT ONE)

No Output ( Standard )

4-20mA Output

4130 Directors Row, Houston, TX 77092 | 713-688-8555


2522 CHOKE POSITION INDICATOR VERSION 17.1

3. CABLE

The 2522 Choke Position Indicator System does not include any cable. Inline Cable is required for new orders; clients
with existing Inline Cable may use the existing cable with a new 2522 Choke Position Indicator System. 4-20mA Cable
is only used if the 4-20mA Output Configuration was selected in Section 2. Cable is purchased in 5’ increments.

Inline Cable: Distance from Sensor to 2522 Gauge Display

4-20mA Output Cable: Distance from 2522 Gauge Display to Local J-Box Termination

4. CERTIFICATION

None, See 2200 Choke Position Indicator

4130 Directors Row, Houston, TX 77092 | 713-688-8555


2522 CHOKE POSITION INDICATOR VERSION 17.1

APPENDIX A: REPLACEMENT SYSTEMS AND PARTS

Full Replacement 2522 Gauge Display

Specify Configuration (Output) and Certification. Must be calibrated with existing HDI 2522 Sensor.

Full Replacement 2522 Sensor (Transducer)

Specify Sensor Connection and Certification. Must be calibrated with existing 2522 Gauge Display.

4130 Directors Row, Houston, TX 77092 | 713-688-8555


9000 CHOKE
CONSOLE SYSTEM
DATA SHEET
W: 36” D: 36” H: 48”

API 16C COMPLIANT

APPLICATION
The HDI 9000 Choke Console Series is a fully customizable choke console, adaptable to a variety of industry standards and regulations. The HDI
9000 Series operates independent of rig power and is the ultimate backup system for critical well control situations. By using HDI Instrumentation
(battery powered, intrinsically safe, and certified), the HDI 9000 Series is ideal for Class 1, Division 1 Hazardous Environments commonly seen on
the drill floor. HDI Instrumentation is designed around a user friendly, field proven platform that has been used for over 20 years.

Attached is a General Assembly Drawing of the HDI 9000 System, giving the user a sense of type of system they will receive.

Prior to ordering a HDI 9000 System, HDI asks our clients to confirm all relevant specifications by filling out the attached questionnaire.
This form will ensure that HDI is delivering a system that is compliant with all rig specific standards.
Below is a standard configuration offered by HDI. Pricing is available upon request.

INSTRUMENTATION HPU/SUB-SYSTEM
• (2) HDI 2000B Pressure Gauge(s): • Directional Control Valves


0-16,000 psi display • Ball Valve


Sensor(s): 2” 2202 Hammer Union Transducers • Speed Adjust Control


with 2’ Pigtails • Hydraulic Reservoir Tank



Cable: 100’ Inline Cable • Pneumatic Air Regulator/Filter


• (1) HDI 2000B Pressure Gauge(s): • Hydraulic Regulating Valve


0-10,000 psi display • Air Driven Hydraulic Pump


Sensor(s): 2” 1502 Hammer Union Transducers • Manual Hydraulic Pump


with 2’ Pigtails • Accumulator Bottle


Cable: 100’ Inline Cable

• (1) HDI 2100 Pump Stroke Counter HDI provides options and solutions for a variety of choke

3 Pump Configuration working pressures and swept volumes.

Sensor(s): 3 Micro-switches

Cable: 100’ Inline Cable, (3) 50’ Pump Leg Cables AVAILABLE ADD-ONS

• (2) HDI 2200 Choke Position Indicator
• Additional Local Indication (Master/Slave Gauges)

0-100% display

• Rig Specific Transducer and Flange Connections Available

Sensor(s): Linear Potentiometer

• 4-20mA Output

Cable: 100’ Inline Cable


• (2) Hydraulic 2 ½” Gauges for Rig Air and Hydraulic Pressure

Rig Air: 0-200 psi

Hydraulic: 0-3,000 psi SAFETY

PRECISION
HDI provides options and solutions for a variety of
INNOVATION
gauge, choke, and pump configurations.
WELL CONTROL MONITORING AT ITS FINEST

4130 Directors Row, Houston, TX 77092 | 713-688-8555

38 of 74 Version 17.2.0
9000 CHOKE CONSOLE SERIES VERSION 16.9

Client: Project Name: Delivery Target:

9000 Choke Console Series - Instrumentation 9000 Choke Console Series - HPU

Pressure Gauges Nominal Choke Working Pressure: _______________ psi


Choke and Kill Pressure Range(s): ________________ psi Swept/Choke Volume: _______________ cubic inches
Standpipe Pressure Range(s): ________________ psi Choke Model: Cameron Expro Shaffer Swaco
Standpipe Gauge Quantity: 1 2 Other: ___________________


Output Option: None 4-20mA
Additional Back-Up Systems (Hand Pump Included):
Slave Gauge(s) (for redundant display)

None Accumulator Bottle
Sensor Connection: 2” 1502 2” 2202 9/16” Autoclave



2” 1502 H2S Other: ______________ Minimum Choke Working Pressure: __________ psi



Inline Cable (Length from Pressure Sensor to Gauge Display in Console): Installation Dimensions: _________ in. x _________ in.

Choke: _______________ ft./mtr.* External Hydraulic Connections: ½” Hard Pipe Hose



Kill: _______________ ft./mtr.* Specify Type/Brand of Hose Connection: _________________

Standpipe: _______________ ft./mtr.* Specify Length (if part of HDI supply): ________ft./mtr.*

Hazardous Location Specification:
If using Slave Output for redundant display: _______________________________________________________________
(Slave Cable Length from Gauge Display to Slave Display): Third Party Testing: ABS DNV Other: ________________
Choke: _______________ ft./mtr.*

Kill: _______________ ft./mtr.* Notes, Exceptions, and Additional Information:

Standpipe: _______________ ft./mtr.* _______________________________________________________________

_______________________________________________________________

Pump Stroke Counter _______________________________________________________________


Number of Pumps: 1 2 3 4 _______________________________________________________________




Sensors: Micro-switch Proximity _______________________________________________________________
Inline Cable: Gauge Display to Common Point (in Pump Room) _____ft./mtr.* _______________________________________________________________
Common Point to each Pump _______ ft./mtr.*

Choke Position Indicator(s)


Quantity: Single Dual


Sensor: Linear Retractable Rotary

Output Option: None 4-20mA

Inline Cable (Length from Sensor to Gauge Display): __________ft./mtr. *

Remote Monitoring/Control: See V9000 Questionnaire


SAFETY
PRECISION
INNOVATION
*Circle ft. or mtr.
WELL CONTROL MONITORING AT ITS FINEST

4130 Directors Row, Houston, TX 77092 | 713-688-8555

39 of 74 Version 17.2.0
40 of 74
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH
01 01
02 02
03 03
04 04
05 05
06 06
07 07
08 08
09 09
10 10
11 11
12 12
13 13
14 14
15 15
16 16
17 17
18 18
19 19
20 20
21 21
22 22
23 23
24 24
25 25
26 26
27 27
28 28
29 29
30 30
31 31
32 32
33 33
34 34

4130 Directors Row, Houston, TX 77092 | 713-688-8555


35 35
36 36
37 37
9000 CHOKE CONSOLE SERIES

38 38
39 39
40 RELEASE RELEASE DATE RELEASE DESCRIPTION AND NOTES DRAFTER ENGINEER APPROVER
40

DATE PROJECT NUMBER SCALE LOCATION REV


HDI Instruments, LLC 4130 Directors Row Houston TX 77092
HDI
Phone: 1.713.688.8555 Fax: 1.713.688.2228 DRAWING NUMBER:
THIS SHEET:
NEXT SHEET:

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH

Version 17.2.0
VERSION 16.9
41 of 74
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH
01 01
02 02
03 03
04 04
05 05
06 06
07 07
08 08
09 09
10 10
11 11
12 12
13 13
14 14
15 15
16 16
17 17
18 18
19 19
20 20
21 21
22 22
23 23
24 24
25 25
26 26
27 27
28 28
29 29
30 30
31 31
32 32
33 33
34 34

4130 Directors Row, Houston, TX 77092 | 713-688-8555


35 35
36 36
9000 CHOKE CONSOLE SERIES

37 37
38 38
39 39
40 RELEASE RELEASE DATE RELEASE DESCRIPTION AND NOTES DRAFTER ENGINEER APPROVER
40

DATE PROJECT NUMBER SCALE LOCATION REV


HDI Instruments, LLC 4130 Directors Row Houston TX 77092
HDI
Phone: 1.713.688.8555 Fax: 1.713.688.2228 DRAWING NUMBER:
THIS SHEET:
NEXT SHEET:

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH

Version 17.2.0
VERSION 16.9
42 of 74
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH
01 01
02 02
03 03
04 04
05 05
06 06
07 07
08 08
09 09
10 10
11 11
12 12
13 13
14 14
15 15
16 16
17 17
18 18
19 19
20 20
21 21
22 22
23 23
24 24
25 25
26 26
27 27
28 28
29 29
30 30
31 31
32 32
33 33

4130 Directors Row, Houston, TX 77092 | 713-688-8555


34 34
35 35
9000 CHOKE CONSOLE SERIES

36 36
37 37
38 38
39 39
40 RELEASE RELEASE DATE RELEASE DESCRIPTION AND NOTES DRAFTER ENGINEER APPROVER
40

DATE PROJECT NUMBER SCALE LOCATION REV


HDI Instruments, LLC 4130 Directors Row Houston TX 77092
HDI
Phone: 1.713.688.8555 Fax: 1.713.688.2228
DRAWING NUMBER:
THIS SHEET:
NEXT SHEET:

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH

Version 17.2.0
VERSION 16.9
43 of 74 Version 17.2.0
44 of 74 Version 17.2.0
Service Plans

45 of 74 Version 17.2.0
Service Plans

HDI offers expert field service of HDI’s products for our clients through HDI’s Service Plans:

Rig Reactivation Plan


&
Annual Preventative Maintenance Plan

HDI’s Service Plans will reactivate stacked rigs efficiently and facilitate a fleet-wide annual preventa-
tive maintenance plan for rigs currently in operation. This service will professionally inspect, re-
pair, and calibrate all HDI systems onboard, and will result in reduced downtime. These plans
will provide HDI systems at the lowest possibly price by offering cost saving incentives.

HDI will ensure that the Service Plan is well implemented to cater to the specific needs of our cus-
tomers in order to achieve overall HDI product reliability and increased efficiency,

For a detailed proposal, contact HDI’s Service Manager

Joseph Ebenezer

713-446-2212

joseph@hdigauges.com

46 of 74 Version 17.2.0
Service Plans

Plan Incentives

20% off Service Job Repair Parts

50% off Batteries when using 10+ HDI Gauge Systems

Highly Reduced Day Rates for 4+ Rigs

Key Advantages

 Significant Cost Reduction and Guaranteed Long-Term Savings

 Industry Standard Gauge Calibration Certificates - Annually

 Reduced Downtime

 Expert OEM Technicians

 Complete System Inspection, Repair, and Calibration

 24 x 7 Dedicated OEM Technical Support

 After Sales Support, Maintenance Planning, and Risk Management

 Improved Operations and Maintenance Manual

 Flexible Options Available for Rig Personnel and Spares

 Training for End Clients and Rig Personnel

47 of 74 Version 17.2.0
48 of 74 Version 17.2.0
Data Sheets

49 of 74 Version 17.2.0
M100 PRESSURE
GAUGE SYSTEM
DATA SHEET

APPLICATION
The HDI M100 Pressure Gauge is a solid-state electronic pressure gauge primarily used for standpipe, pumping, and cementing measurement applica-
tions. The HDI M100 is used where indication at the point of measurement is a must and the ability to handle high vibration and harsh environments is
crucial. It is easily readable regardless of the lighting conditions. This model offers pressure ranges up to 16,000 psi with accuracy of 0.5% of full scale
to NIST. It has been used in the field for over 10 years and is based on HDI’s 25 year field proven platform. All HDI Gauges provide safety, accuracy,
reliability, and low maintenance for the user.

FEATURES OPTIONS
• Battery powered • 4-20mA output (additional barrier required)


• Field repairable system • 0-1 volt output


• Low battery indicator • Slave, secondary displays available


• 6,000 psi, 10,000 psi, 16,000 psi; kPa and bar equivalents included • Backlight, 12VDC or 24VDC required


• 10 psi resolution

• 2” 1502, 2” 2202, or flanged connections

• Solid state platform; no fluids or moving parts CERTIFICATIONS

• Analog bar graph w/ divided scale • No certifications available, see HDI 2000P


• Consistent performance in high vibration environments

SAFETY
PRECISION
INNOVATION
WELL CONTROL MONITORING AT ITS FINEST
50 of 74 Version 17.2.0
M100 PRESSURE GAUGE SYSTEM
DATA SHEET

SPECIFICATIONS DIMENSIONS
• Weight: 25.1 Lbs (as shown with 1502 Hammer Union) All dimensions given are in inches and [millimeters] unless

• Case Material: High impact polyurethane otherwise noted.

• Accuracy: 0.5% of full scale to NIST

• Pressure Range: 6,000 psi, 10,000 psi, 16,000 psi resolutions and

kPa/bar equivalents
• Engineering Units: psi, bar, and kPa available

• Resolution: 10 psi increments

• Power: HDI E260 Battery Pack, 1 year life span

• Gauge Head Operating Temperature: -40°F to 176°F (-40°C to 80°C)

• Media (Process) Temperature: -30°F to 212°F (-30°C to 100°C)

• Display: 5 digit digital display, circular analog bar graph, low battery

indicator
• Viewing Distance: 30 feet

• Electronics Protection: Weatherproof sealed and mounted in shock

protection material
• Front Panel Protection: 1/4” thick clear lens

• Sensor Housing: 2” 1502, 2” 2202, flanged connections

• Sensor Protection: Primary and secondary rubber diaphragms

• Media Pressure Port: Fluids compatible with 410 QDT

stainless steel
• Maximum 4-20mA Output Cable Length: 250 feet

SAFETY
Specifications subject to change without notice. HDI Instruments, LLC is a registered ISO 9001:2000 company.
PRECISION
Copyright 2015 HDI Instruments, LLC
HDI Instruments, LLC, 4130 Directors Row, Houston, TX 77092 USA
INNOVATION
Phone: 713-688-8555 | Fax: 713-688-2228 | Contact Email: info@hdigauges.com | Website: www.hdigauges.com WELL CONTROL MONITORING AT ITS FINEST
Version 1.5
51 of 74 Version 17.2.0
2000B PRESSURE
GAUGE SYSTEM
DATA SHEET

APPLICATION
The HDI Pressure Gauge is the product HDI was founded on. The HDI 2000B is our latest battery-operated cornerstone product; it is an intrinsically
safe, certified, solid-state electronic pressure gauge primarily used for choke console applications. It is easily readable regardless of the lighting
conditions. HDI routinely builds, installs, and services custom HDI 9000 Choke Console Systems designed with HDI 2000B gauges, but the 2000B
can also be purchased to retrofit standard 6” hydraulic gauges or for OEM use. HDI additionally offers stand-alone monitoring systems with the
2000B – anywhere the user needs a primary and/or secondary (slave option available) display. This model offers pressure ranges up to up to 16,000
psi with accuracy of 0.5% of full scale to NIST. Each 2000B is comprised of a Gauge Display, Inline Cable, and Sensor Assembly allowing the display
to be close or far from the connection point. It has been used in the field for over 25 years and is based on HDI’s 25 year field proven platform. All HDI
Gauges provide safety, accuracy, reliability, and low maintenance for the user.

FEATURES OPTIONS
• Battery powered • 4-20mA output (additional barrier required)


• Field repairable system • 4-20mA input (non-certified option)


• Low battery indicator • Backlight, 12VDC or 24VDC required (non-certified option)


• 30 psi, 100 psi, 300 psi, 1,000 psi, 3,000 psi, 6,000 psi, 10,000 psi, • Externally powered, 12VDC or 24VDC required


16,000 psi pressure ranges; kPa and bar equivalents included (non-certified option)
• 1” Male NPT, 2” 1502, 2” 2202, or 9/16” Autoclave x Flanged • 0-1 volt output


Connections • Slave, secondary displays available

• Solid state platform; no fluids or moving parts

• Analog bar graph w/ divided scale

• Simple interface for calibration CERTIFICATIONS

• CSA: Intrinsically Safe Class 1, Division 1, Groups A, B, C and D
• ATEX: optional, II 1 G, Ex ia IIC T4
• IECEX: (in progress)

SAFETY
PRECISION
INNOVATION
WELL CONTROL MONITORING AT ITS FINEST
52 of 74 Version 17.2.0
2000B PRESSURE GAUGE SYSTEM
DATA SHEET

SPECIFICATIONS DIMENSIONS
• Weight: 3.4 Lbs (as shown gauge display only) All dimensions given are in inches and [millimeters] unless

• Case Material: black phenolic, aluminum optional otherwise noted.

• Accuracy: 0.5% of full scale to NIST

• Pressure Range: 30 psi, 100 psi, 300 psi, 1,000 psi, 3,000 psi,

6,000 psi, 10,000 psi, and 16,000 psi, resolutions and kPa/bar
equivalents
• Engineering Units: psi, bar, and kPa available

• Resolution: 10 psi increments

• Power: HDI E260 Battery Pack, 1 year life span

• Gauge Head Operating Temperature: -40°F to 176°F (-40°C to 80°C)

• Media (Process) Temperature: -30°F to 212°F (-30°C to 100°C)

• Display: 5 digit digital display, circular analog bar graph, low

battery indicator
• Viewing Distance: 30 feet

• Electronics Protection: Gasket seal

• Front Panel Protection: 0.015” clear lens

• Sensor Housing: 1” Male NPT, 2” 1502, 2” 2202, 9/16” Autoclave x

Flanged Connections
• Sensor Protection: Primary and secondary rubber diaphragms

• Media Pressure Port: Fluids compatible with 410 QDT stainless steel

• Mounting: Standard 3-hole and 4-hole mounting patterns

• Maximum Inline Cable Length (distance from gauge head to point of

measurement): 1,500 feet
• Maximum 4-20mA Output Cable Length: 250 feet

SAFETY
Specifications subject to change without notice. HDI Instruments, LLC is a registered ISO 9001:2008 company.
PRECISION
Copyright 2015 HDI Instruments, LLC
HDI Instruments, LLC, 4130 Directors Row, Houston, TX 77092 USA
INNOVATION
Phone: 713-688-8555 | Fax: 713-688-2228 | Contact Email: info@hdigauges.com | Website: www.hdigauges.com WELL CONTROL MONITORING AT ITS FINEST
Version 1.5
53 of 74 Version 17.2.0
2000P PRESSURE
GAUGE SYSTEM
DATA SHEET

APPLICATION
The HDI 2000P Pressure Gauge is an intrinsically safe, certified, solid-state electronic pressure gauge primarily used for Standpipe, Pumping, and
Cementing applications. The 2000P can act as a primary or secondary pressure readout for the user. It is easily readable regardless of the lighting
conditions. The HDI 2000P is used where indication at the point of measurement is a must while also needing to handle high vibration and/or rugged
environments. This model offers pressure ranges up to 16,000 psi with accuracy of 0.5% of full scale to NIST. It is based on the M100 (non-certified
version) which has been used in the field for over 10 years and is based on HDI’s 25 year field proven platform. All HDI Gauges provide safety,
accuracy, reliability, and low maintenance for the user.

FEATURES OPTIONS
• Battery powered • 4-20mA output (under development)


• Field repairable system • 0-1 volt output


• Low battery indicator • Slave, secondary displays available


• 6,000 psi, 10,000 psi, 16,000 psi; kPa and bar equivalents included

• 10 psi resolution

• 2” 1502, 2” 2202, or flanged connections

• Solid state platform; no fluids or moving parts CERTIFICATIONS

• Analog bar graph w/ divided scale • CSA: Intrinsically Safe Class 1, Division 1, Groups A, B, C and D

• Consistent performance in high vibration environments • ATEX: optional, II 1 G, Ex ia IIC T4

• Simple interface for calibration • IECEX: (in process)

SAFETY
PRECISION
INNOVATION
WELL CONTROL MONITORING AT ITS FINEST
54 of 74 Version 17.2.0
2000P PRESSURE GAUGE SYSTEM
DATA SHEET

SPECIFICATIONS DIMENSIONS
• Weight: 25.1 Lbs (as shown with 1502 Hammer Union) All dimensions given are in inches and [millimeters] unless

• Case Material: High impact polyurethane otherwise noted.

• Accuracy: 0.5% of full scale to NIST

• Pressure Range: 6,000 psi, 10,000 psi, 16,000 psi resolutions

and kPa/bar equivalents
• Engineering Units: psi, bar, and kPa available

• Resolution: 10 psi increments

• Power: HDI E260 Battery Pack, 1 year life span

• Gauge Head Operating Temperature: -40°F to 176°F (-40°C to 80°C)

• Media (Process) Temperature: -30°F to 212°F (-30°C to 100°C)

• Display: 5 digit digital display, circular analog bar graph, low

battery indicator
• Viewing Distance: 30 feet

• Electronics Protection: Weatherproof sealed and mounted in shock

protection material
• Front Panel Protection: 1/4” thick clear lens

• Sensor Housing: 2” 1502, 2” 2202, flanged connections

• Sensor Protection: Primary and secondary rubber diaphragms

• Media Pressure Port: Fluids compatible with 410 QDT

stainless steel

SAFETY
Specifications subject to change without notice. HDI Instruments, LLC is a registered ISO 9001:2008 company.
PRECISION
Copyright 2015 HDI Instruments, LLC
HDI Instruments, LLC, 4130 Directors Row, Houston, TX 77092 USA
INNOVATION
Phone: 713-688-8555 | Fax: 713-688-2228 | Contact Email: info@hdigauges.com | Website: www.hdigauges.com WELL CONTROL MONITORING AT ITS FINEST
Version 1.5
55 of 74 Version 17.2.0
2021 PRESSURE
TRANSMITTER SYSTEM
DATA SHEET

APPLICATION
The HDI 2021 Pressure Transmitter is an intrinsically safe, certified, field-repairable 4-20mA transmitter built with high quality components HDI is
known for throughout its line of products. The transducer (sensor) is an embedded strain gauge placed in a stainless steel housing. HDI’s Transmitter
is unique because of its field repairability. If the pill or internal board are damaged due to use over time, the user is able to order the spare parts
necessary to fix the unit quickly onsite, reducing downtime and saving on overall cost. Video tutorials are available to assist in the repair online.

The 2021 Transmitter is commonly housed in a 1502 Hammer Union. However, the customer may specify a variety of housings to suit their application
(2” 1502 Hammer Union, 2” 2202 Hammer Union, or a flanged connection). The transmitter is delivered as a complete assembly ready for installation.
All HDI Transmitters provide safety, accuracy, reliability, and low maintenance for the user.

FEATURES CERTIFICATIONS
• 4-20mA output • CSA: Intrinsically Safe Class 1, Division 1, Groups A, B, C and D

• Field repairable system • ATEX: optional, II 1 G, Ex ia IIC T4

• 6,000 psi, 10,000 psi, 16,000 psi • IECEX: (in process)

• 2” 1502, 2” 2202, or 9/16” Autoclave x Flanged Connections

• Solid state platform; no fluids or moving parts

SAFETY
PRECISION
INNOVATION
WELL CONTROL MONITORING AT ITS FINEST
56 of 74 Version 17.2.0
2021 PRESSURE TRANSMITTER SYSTEM
DATA SHEET

SPECIFICATIONS DIMENSIONS
• Weight: 18.2 lbs (as shown with 1502 hammer union) All dimensions given are in inches and [millimeters] unless

• Accuracy: 0.5% of full scale to NIST otherwise noted.

• Pressure Range: 6,000 psi, 10,000 psi, 16,000 psi resolutions

• Power: Customer supplied 24 vdc

• Media (Process) Temperature: -30°F to 212°F (-30°C to 100°C)

• Sensor Housing: 2” 1502, 2” 2202, 9/16” Autoclave x Flanged

Connections
• Sensor Protection: Primary and secondary rubber diaphragms

• Media Pressure Port: Fluids compatible with 410 QDT stainless steel

• Maximum 4-20mA Output Cable Length: 250 feet

SAFETY
Specifications subject to change without notice. HDI Instruments, LLC is a registered ISO 9001:2008 company.
PRECISION
Copyright 2015 HDI Instruments, LLC
HDI Instruments, LLC, 4130 Directors Row, Houston, TX 77092 USA
INNOVATION
Phone: 713-688-8555 | Fax: 713-688-2228 | Contact Email: info@hdigauges.com | Website: www.hdigauges.com WELL CONTROL MONITORING AT ITS FINEST
Version 1.5
57 of 74 Version 17.2.0
2100 PUMP STROKE
COUNTER SYSTEM
DATA SHEET

APPLICATION
The HDI 2100 Pump Stroke Counter is an intrinsically safe, certified, solid-state electronic stroke counter primarily used for monitoring mud pumps.
Found most commonly within the HDI 9000 Choke Console System, the HDI 2100 monitors and displays the total accumulated mud pump strokes
and the stroke rate of up to 4 individual mud pumps simultaneously. The stroke rate for each mud pump can be individually selected for display and
is updated every second. Once installed, there is virtually no maintenance or calibration required. The quartz crystal oscillator provides high preci-
sion counts with no drift. The stainless steel case is completely sealed and features stainless steel piezo switches for long life. The entire package is
constructed to operate in harsh environments and high vibration conditions encountered in land and offshore drilling. All HDI Gauges provide safety,
accuracy, reliability, and low maintenance for the user.

FEATURES OPTIONS
• Battery powered • Externally powered, 12VDC or 24VDC required


• Field repairable system (non-certified option)

• Low battery indicator • Backlight, 12VDC or 24VDC required (non-certified option)


• Monitor 1, 2, 3, or 4 pumps simultaneously

• Micro-switch or proximity sensor

• Dual sensors available for HMI/PLC integration
CERTIFICATIONS

• Solid state display

• CSA: Intrinsically Safe Class 1, Division 1, Groups A, B, C and D
• Simple interface for calibration

• ATEX: optional, II 1 G, Ex ia IIC T4
• IECEX: (in process)

SAFETY
PRECISION
INNOVATION
WELL CONTROL MONITORING AT ITS FINEST
58 of 74 Version 17.2.0
2100 PUMP STROKE COUNTER SYSTEM
DATA SHEET

SPECIFICATIONS DIMENSIONS
• Weight: 5 lbs (as shown gauge display only) All dimensions given are in inches and [millimeters] unless

• Case Material: Stainless steel otherwise noted.

• Stroke Rate Range: 11 - 300 spm

• Total Accumulated Strokes Displayed: 65,535 strokes

• Power: HDI E260 Battery Pack, 1 year life span

• Gauge Head Operating Temperature: -40°F to 176°F (-40°C to 80°C)

• Display: Liquid crystal display of total strokes and selected

pump spam
• Time Base: Quartz crystal oscillator

• Viewing Distance: 30 feet HDI

www.hdigauges.com
• Electronics Protection: Gasket seal POWER

DISPLAY

• Sensor Housing: Micro-switch or proximity sensor


CLEAR

TTL STROKES
• Maximum Inline Cable Length (distance from gauge head to point of LOW BATT SELECT

measurement): 1,500 feet

PUMP STROKES / MIN

1 2 3 4

PUMP SELECT

HDI
www.hdigauges.com
POWER
DISPLAY

CLEAR
TTL STROKES
LOW BATT SELECT

PUMP STROKES / MIN

1 2 3 4

PUMP SELECT

SAFETY
Specifications subject to change without notice. HDI Instruments, LLC is a registered ISO 9001:2008 company.
PRECISION
Copyright 2015 HDI Instruments, LLC
HDI Instruments, LLC, 4130 Directors Row, Houston, TX 77092 USA
INNOVATION
Phone: 713-688-8555 | Fax: 713-688-2228 | Contact Email: info@hdigauges.com | Website: www.hdigauges.com WELL CONTROL MONITORING AT ITS FINEST
Version 1.5
59 of 74 Version 17.2.0
2200 CHOKE POSITION
INDICATOR SYSTEM
DATA SHEET

APPLICATION
The HDI 2200 Choke Position Indicator System is an intrinsically safe, certified, solid-state electronic choke position indicator used to monitor the
choke position in 1% increments from 0% to 100%. Found most commonly within the HDI 9000 Choke Console System, the HDI 2200 can adapt to
a variety of chokes found within the oil and gas industry using a linear potentiometer, rotary potentiometer, or retractable potentiometer. The HDI 2200
eliminates the need for air lines to the position indicator. All HDI Gauges provide safety, accuracy, reliability, and low maintenance for the user.

FEATURES OPTIONS
• Battery powered • 4-20mA output (additional barrier required)


• Field repairable system • 4-20mA input (non-certified option)


• Low battery indicator • Externally powered, 12VDC or 24VDC required


• Interfaces with linear, rotary, or retractable potentiometers (non-certified option)

• Replaces pneumatically controlled units • Backlight, 12VDC or 24VDC required (non-certified option)


• Dual sensors available for HMI/PLC integration • 0-1 volt output


• Solid state display

• Analog bar graph w/ divided scale

• Simple interface for calibration CERTIFICATIONS

• CSA: Intrinsically Safe Class 1, Division 1, Groups A, B, C and D
• ATEX: optional, II 1 G, Ex ia IIC T4
• IECEX: (in process)

SAFETY
PRECISION
INNOVATION
WELL CONTROL MONITORING AT ITS FINEST
60 of 74 Version 17.2.0
2200 CHOKE POSITION INDICATOR SYSTEM
DATA SHEET

SPECIFICATIONS DIMENSIONS
• Weight: 5 lbs (as shown gauge display only) All dimensions given are in inches and [millimeters] unless

• Case Material: Stainless steel otherwise noted.

• Resolution: 1% increments

• Power: HDI E260 Battery Pack, 1 year life span

• Display: 4 digit digital display, 0-100% and 1/8” scale, linear analog

bar graph, low battery indicator
• Gauge Head Operating Temperature: -40°F to 176°F (-40°C to 80°C)

• Viewing Distance: 30 feet

• Electronics Protection: Gasket seal HDI

• Sensor Housing: Linear potentiometer, rotary potentiometer, or M

retractable potentiometer
• Maximum Inline Cable Length (distance from gauge head to point of 100

95
90

measurement): 1,500 feet 85


80
75

• Maximum 4-20mA Output Cable Length: 250 feet


70
65

60
55
50 E
45
40
35
30
25
20
15
10
5
0
RUN

POWER

www.hdigauges.com

HDI
M

100
95
90
85
80
75
70
65
60
55
50 E
45
40
35
30
25
20
15
10
5
0
RUN

POWER

www.hdigauges.com

SAFETY
Specifications subject to change without notice. HDI Instruments, LLC is a registered ISO 9001:2008 company.
PRECISION
Copyright 2015 HDI Instruments, LLC
HDI Instruments, LLC, 4130 Directors Row, Houston, TX 77092 USA
INNOVATION
Phone: 713-688-8555 | Fax: 713-688-2228 | Contact Email: info@hdigauges.com | Website: www.hdigauges.com WELL CONTROL MONITORING AT ITS FINEST
Version 1.5
61 of 74 Version 17.2.0
2250 VALVE POSITION
INDICATOR SYSTEM
DATA SHEET

APPLICATION
The HDI 2250 Valve Position Indicator (VPI) System allows the user to monitor the position of manual and hydraulically actuated gate valves found
primarily on the choke manifold. Traditionally, manual gate valves do not have a position indicator found on the valve. The 2250 System solves this
problem by adding an adapter onto the valve, while not compromising the integrity or certification of the valve, to give the user valve position locally.
The user can also remotely see the position of all valves being monitored on a virtual P&ID of the entire manifold.

The 2250 can be utilized for non-rising stem gate valves taking into account various bonnet sizes and manufacturers. Once installed, this System
has little maintenance. The VPI System can be easily integrated with HDI’s V9000 Virtual Choke Console System and has been field proven for over 5
years offshore.

FEATURES OPTIONS
• Adapts to various manual gate valve sizes and models • Remote virtual position with client specific P&ID
• Does not compromise the integrity of the valve being monitored • Integration with HDI V9000 Virtual Choke Console System
• Namur and proximity switch capabilities
• Local and remote visual displays of valve position

CERTIFICATIONS
• Comprised of components certified for Class 1, Division 1
hazardous environments

SAFETY
PRECISION
INNOVATION
WELL CONTROL MONITORING AT ITS FINEST
62 of 74 Version 17.2.0
2250 VALVE POSITION INDICATOR SYSTEM
DATA SHEET

SPECIFICATIONS DIMENSIONS
• Weight : 15.3 lbs with Junction Box mounted All dimensions given are in inches and [millimeters] unless
Case
• Material: 316 Stainless Steel otherwise noted.
• Sensor: Inductive Namur Sensor
• Sensor Power : 5 to 25 VDC
• Type of Valve : Rising Stem Gate Valves

Lower adapter diameter will change and is dependent on valve bonnet size

SAFETY
Specifications subject to change without notice. HDI Instruments, LLC is a registered ISO 9001:2008 company.
PRECISION
Copyright 2015 HDI Instruments, LLC
HDI Instruments, LLC, 4130 Directors Row, Houston, TX 77092 USA
INNOVATION
Phone: 713-688-8555 | Fax: 713-688-2228 | Contact Email: info@hdigauges.com | Website: www.hdigauges.com
WELL CONTROL MONITORING AT ITS FINEST
Version 1.5
63 of 74 Version 17.2.0
2400 PRESSURE
GAUGE SYSTEM
DATA SHEET

APPLICATION
The HDI 2400 Pressure Gauge System has the same overall function and application as the 2000B Panel Gauge System. However, the HDI 2400 has
alarm options that give the user a gauge system with the ability to automatically shut down pumps or put engines into neutral when the set point is
reached. This model offers pressure ranges up to 16,000 psi with accuracy of 0.5% of full scale. Each 2400 is comprised of a Gauge Display, Inline
Cable, and Sensor Assembly allowing the display to be close or far from the connection point. It has been used in the field for over 20 years and is
based on HDI’s 25 year field proven platform. All HDI Gauges provide safety, accuracy, reliability, and low maintenance for the user.

FEATURES OPTIONS
• Battery powered • 4-20mA output (additional barrier required)


• Field repairable system • 4-20mA input (non-certified option)


• Low battery indicator • Externally powered, 12VDC or 24VDC required


• 6,000 psi, 10,000 psi, 16,000 psi pressure ranges; kPa and bar (non-certified option)

equivalents included • Backlight, 12VDC or 24VDC required (non-certified option)

• 10 psi resolution • 0-1 volt output


• 1” Male NPT, 2” 1502, 2” 2202, or 9/16” Autoclave x Flanged • Slave, secondary displays available, independent alarm set points


Connections
• Solid state platform; no fluids or moving parts

• Analog bar graph w/ divided scale, automatically scales to high CERTIFICATIONS

alarm set point • CSA: Intrinsically Safe Class 1, Division 1, Groups A, B, C and D
• Multiple engineering units • ATEX: optional, II 1 G, Ex ia IIC T4

• Adjustable high/low alarm set point

SAFETY
PRECISION
INNOVATION
WELL CONTROL MONITORING AT ITS FINEST
64 of 74 Version 17.2.0
2400 PRESSURE GAUGE SYSTEM
DATA SHEET

SPECIFICATIONS DIMENSIONS
• Weight: 5 lbs (as shown gauge display only) All dimensions given are in inches and [millimeters] unless

• Case Material: black phenolic, aluminum optional otherwise noted.

• Accuracy: 0.5% of full scale

• Pressure Range: 6,000 psi, 10,000 psi, 16,000 psi resolutions and

kPa/bar equivalents
• Engineering Units: psi, bar, and kPa available

• Resolution: 10 psi increments

• Power: HDI E260 Battery Pack, 1 year life span 500 600

400 700

• Gauge Head Operating Temperature: -40°F to 176°F (-40°C to 80°C) 300 800

200 7 8 9 10 900
6

• Media (Process) Temperature: -30°F to 212°F (-30°C to 100°C)


5 11
4 12

HDI
3 13

2 14

• Display: 5 digit digital display, circular analog bar graph, low 1


0
15
16

hdigauges.com
battery indicator BAR PSI PSI BAR

• Viewing Distance: 30 feet



• Electronics Protection: Gasket seal

• Sensor Housing: 1” Male NPT, 2” 1502, 2” 2202, flanged connections

• Sensor Protection: Primary and secondary rubber diaphragms

• Media Pressure Port: Fluids compatible with 410 QDT stainless steel

• Mounting: Standard 3-hole and 4-hole mounting patterns

• Maximum Inline Cable Length (distance from gauge head to point of

measurement): 1,500 feet
• Maximum 4-20mA Output Cable Length: 250 feet

500 600
400 700

300 800

200 7 8 9 10 900
6
5 11
4 12

HDI
3 13
2 14
1 15
0 16
hdigauges.com
BAR PSI PSI BAR

SAFETY
Specifications subject to change without notice. HDI Instruments, LLC is a registered ISO 9001:2008 company. PRECISION
Copyright 2015 HDI Instruments, LLC
HDI Instruments, LLC, 4130 Directors Row, Houston, TX 77092 USA
INNOVATION
Phone: 713-688-8555 | Fax: 713-688-2228 | Contact Email: info@hdigauges.com | Website: www.hdigauges.com
WELL CONTROL MONITORING AT ITS FINEST
Version 1.5
65 of 74 Version 17.2.0
2522 CHOKE POSITION
INDICATOR SYSTEM
DATA SHEET

APPLICATION
The HDI 2522 Choke Position Indicator System is a 4” solid-state electronic choke position indicator used to monitor the choke position in 1% incre-
ments from 0% to 100%. The HDI 2522 can adapt to a variety of chokes in the oil and gas industry using a linear potentiometer, rotary potentiometer,
or retractable potentiometer. The HDI 2522 eliminates the need for air lines to the position indicator. All HDI Gauges provide safety, accuracy, reliability,
and low maintenance for the user.

FEATURES OPTIONS
• Battery powered • 4-20mA output (under development)


• Field repairable system

• Low battery indicator

• Interfaces with linear, rotary, or retractable potentiometers

• Replaces pneumatically controlled units

• Dual sensors available for HMI/PLC integration CERTIFICATIONS

• Solid state display • IECEX: (in process)

• Analog bar graph w/ divided scale • ATEX: (in process)

• Simple interface for calibration

SAFETY
PRECISION
INNOVATION
WELL CONTROL MONITORING AT ITS FINEST
66 of 74 Version 17.2.0
2522 CHOKE POSITION INDICATOR SYSTEM
DATA SHEET

SPECIFICATIONS DIMENSIONS
• Weight: 2 lbs (as shown gauge display only) All dimensions given are in inches and [millimeters] unless

• Case Material: Polycarbonate/PBT Alloy, Impact modified, otherwise noted.

UV stabilized
• Resolution: 1% increments

• Power: HDI E610 Battery Pack, 1 year life span

• Gauge Head Operating Temperature: -40°F to 176°F (-40°C to 80°C)

• Display: 3 digit digital display, 0-100% and 1/8” scale, linear analog

bar graph, low battery indicator
• Viewing Distance: 15 feet HDI
hdigauges.com

• Electronics Protection: Gasket seal

• Potentiometer: accepts linear, rotary, retractable, and a wide range of

2k-25k ohm potentiometers
• Maximum Inline Cable Length (distance from gauge head to point of

measurement): 1,500 feet  

HDI
hdigauges.com

 

SAFETY
Specifications subject to change without notice. HDI Instruments, LLC is a registered ISO 9001:2008 company.
PRECISION
Copyright 2015 HDI Instruments, LLC
HDI Instruments, LLC, 4130 Directors Row, Houston, TX 77092 USA
INNOVATION
Phone: 713-688-8555 | Fax: 713-688-2228 | Contact Email: info@hdigauges.com | Website: www.hdigauges.com WELL CONTROL MONITORING AT ITS FINEST
Version 1.5
67 of 74 Version 17.2.0
3200 MGS DIFFERENTIAL
MONITORING SYSTEM
DATA SHEET

APPLICATION
The HDI 3200 Mud Gas Separator Monitoring System is composed of intrinsically safe, solid-state electronic pressure gauges used to monitor the
liquid seal pressure, mud gas pressure, differential pressure between the liquid seal and mud gas pressures, and temperature parameters found within
the Mud Gas Separator. The 3200 System is comprised of HDI 2000B or 2400 Gauge Systems as well as the 3300 Temperature Gauge.

This System can monitor pressure ranges up to 300 psi and temperatures up to 150 Celsius with 0.5% accuracy of full scale. Each 2000B and 3300 is
comprised of a Gauge Display, Inline Cable, and Sensor Assembly allowing the display to be close or far from the point of measurement. This System
is customizable to client specifications and/or space constraints, and it is based on HDI’s 25 year field proven platform. All HDI Gauges provide safety,
accuracy, reliability, and low maintenance for the user.

FEATURES OPTIONS
• Battery powered • 4-20mA output (additional barrier required)


• Field repairable system • 4-20mA input (non-certified option)


• Low battery indicator • Backlight, 12VDC or 24VDC required (non-certified option)


• 30 psi, 100 psi, 300 psi; kPa or bar available upon request • Externally powered, 12VDC or 24VDC required



• 1 psi resolution (non-certified option)

• -50 to 150 celsius; -50 to 300 fahrenheit • 0-1 volt output


• 1” Male NPT, 2” Male NPT, 2” 1502, 2” 2202, or 9/16” Autoclave x • Slave, secondary displays available


Flanged Connections
• Solid state platform; no fluids or moving parts
CERTIFICATIONS

• Analog bar graph w/ divided scale

• Simple interface for calibration • CSA: Intrinsically Safe Class 1, Division 1, Groups A, B, C and D


• Verify temperatures with a solid state RTD • ATEX: optional, II 1 G, Ex ia IIC T4


• Customizable bracket sizes and gauge configurations • IECEX: (in progress)


SAFETY
PRECISION
INNOVATION
WELL CONTROL MONITORING AT ITS FINEST
68 of 74 Version 17.2.0
3200 MGS DIFFERENTIAL MONITORING
SYSTEM
DATA SHEET

BRACKET SPECIFICATIONS GAUGE SPECIFICATIONS


• Weight: 30.4 lbs (as shown bracket with gauges only) • (3) 2000B Pressure Gauge Systems Included


• Case Material: 316 stainless steel (See 2000B Data Sheet for further details)

• Viewing Angle: 45 degrees or

• Viewing Distance: 30 feet • (3) 2400 Pressure Gauge Systems Included


(See 2400 Data Sheet for further details)

• (1) 3300 Temperature Gauge System Included


(See 3300 Data Sheet for further details)

DIMENSIONS
All dimensions given are in inches and [millimeters] unless
otherwise noted.

HDI
www.hdigauges.com

HDI
50 50 50
40 60 40 60 40 60

30 70 30 70 30 70
www.hdigauges.com
50 50 50
80 80 40 60 40 80 60 40 60
20 20 20
3 4 3 4 70
3 4 70 70
30 30 30
2 5 2 5 2 5
90 90 20 80 90 80 80
10 10 10

HDI HDI HDI


20 20
3 4 3 4 3 4
1 6 1 6 1 6
2 5 2 5 2 5
90 90 90
10 10 10

HDI HDI HDI


0 7 0 7 1 6 0 17 6 1 6

hdigauges.com hdigauges.com 7
hdigauges.com 7 7
0 0 0
PSI BAR BAR PSI PSI BAR BAR PSI hdigauges.com PSI BAR BARhdigauges.com
PSI hdigauges.com
PSI BAR BAR PSI PSI BAR BAR PSI PSI BAR BAR PSI

LIQUID SEAL DIFFERENTIAL MGS PRESS MGS TEMP


LIQUID SEAL DIFFERENTIAL MGS PRESS MGS TEMP

STANDARD BRACKET
STANDARD BRACKET

SAFETY
Specifications subject to change without notice. HDI Instruments, LLC is a registered ISO 9001:2008 company.
PRECISION
Copyright 2015 HDI Instruments, LLC
HDI Instruments, LLC, 4130 Directors Row, Houston, TX 77092 USA
INNOVATION
Phone: 713-688-8555 | Fax: 713-688-2228 | Contact Email: info@hdigauges.com | Website: www.hdigauges.com WELL CONTROL MONITORING AT ITS FINEST
Version 1.5
69 of 74 Version 17.2.0
3300 TEMPERATURE
GAUGE SYSTEM
DATA SHEET

APPLICATION
The HDI 3300 Temperature Gauge System is an intrinsically safe, certified, solid-state electronic temperature gauge routinely used for monitoring
high pressure nitrogen pumping, geothermal and mud based drilling, bulk liquid storage, well control manifolds, and flare stacks. This model offers
temperature ranges up to 150 Celsius or 300 Fahrenheit with 0.5% accuracy of full scale. Each gauge system is comprised of a Gauge Display, Inline
Cable, and Sensor Assembly allowing the display to be close or far from the point of measurement. All HDI Gauges provide safety, accuracy, reliability,
and low maintenance for the user.

FEATURES OPTIONS
• Battery powered • 4-20mA output (additional barrier required)


• Field repairable system • 4-20mA input (non-certified option)


• Low battery indicator • Externally powered, 12VDC or 24VDC required


• -50°F to 300°F (-50°C to 150°C) (non-certified option)

• 0.1 degree resolution • Backlight, 12VDC or 24VDC required (non-certified option)


• 1” Male NPT, 2” 1502, 2” 2202, or flanged connections • 0-1 volt output


• Solid state platform; no fluids or moving parts • Slave, secondary displays available


• Analog bar graph w/ divided scale

• Simple interface for calibration

• Verify temperatures with a solid state RTD

• Toggle between fahrenheit and celsius
CERTIFICATIONS

• CSA: Intrinsically Safe Class 1, Division 1, Groups A, B, C and D
• ATEX: optional, II 1 G, Ex ia IIC T4

SAFETY
PRECISION
INNOVATION
WELL CONTROL MONITORING AT ITS FINEST
70 of 74 Version 17.2.0
3300 TEMPERATURE GAUGE SYSTEM
DATA SHEET

SPECIFICATIONS DIMENSIONS
• Weight: 5 lbs (as shown gauge display only) All dimensions given are in inches and [millimeters] unless

• Case Material: black phenolic, aluminum optional otherwise noted.

• Accuracy: 0.5% of full scale

• Engineering Units: celsius, fahrenheit

• Resolution: 0.1 degree increments

• Power: HDI E260 Battery Pack, 1 year life span

• Gauge Head Operating Temperature: -40°F to 176°F (-40°C to 80°C) HDI
www.hdigauges.com

• Displayed Ranges: -50°F to 300°F (-50°C to 150°C)

• Display: 5 digit digital display, circular analog bar graph, low

battery indicator
• Viewing Distance: 30 feet

• Electronics Protection: Gasket seal

• Sensor Housing: 1” Male NPT, 2” 1502, 2” 2202, flanged connections

• Sensor Protection: Primary and secondary rubber diaphragms

• Media Pressure Port: Fluids compatible with 410 QDT stainless steel

• Mounting: Standard 3-hole and 4-hole mounting patterns

• Maximum Inline Cable Length (distance from gauge head to point of

measurement): 1,500 feet
• Maximum 4-20mA Output Cable Length: 250 feet

HDI
www.hdigauges.com

SAFETY
Specifications subject to change without notice. HDI Instruments, LLC is a registered ISO 9001:2008 company.
PRECISION
Copyright 2015 HDI Instruments, LLC
HDI Instruments, LLC, 4130 Directors Row, Houston, TX 77092 USA
INNOVATION
Phone: 713-688-8555 | Fax: 713-688-2228 | Contact Email: info@hdigauges.com | Website: www.hdigauges.com WELL CONTROL MONITORING AT ITS FINEST
Version 1.5
71 of 74 Version 17.2.0
International - Authorized Agents

HDI’s Global Headquarters is in Houston, Texas. HDI products, however, are used by clients
worldwide. The need for local sales, repair, and support for our clients is critical. Since 2014,
we have expanded our reach by establishing Authorized Agents in key regions around the world.

These Authorized Agents will offer sales support and provide calibration and basic repair services at
their facilities to HDI clients in their region. The Agents have been trained by HDI Technicians
to properly replace batteries, troubleshoot, fix, and calibrate HDI Systems.

HDI continues to look for new, competent, qualified Authorized Agents to actively sell and support
HDI products within their region.

For further information, contact HDI’s International Business Development Manager

Will Condon

713-303-9580

will@hdigauges.com

72 of 74 Version 17.2.0
International - Authorized Agents

Aberdeen, Scotland

Monitor Systems Scotland Limited

3 Merkland Road East

Aberdeen: AB24 5PS

Scotland, United Kingdom

www.monitor-systems-engineering.com

Contact: Brian Sinclair

Office: +44 (0) 1224 621 073

Mobile: +44 (0) 7713 620 608

Email: sales@monitor-systems.co.uk

Dubai, United Arab Emirates

Adghal Oilfield Supplies LLC

Al Qusais Industrial Area No: 1

P.O. Box - 62738, Dubai

www.adghaloilfield.com

Contact: Mohammed Shafee

Office: +971 4 2679402

Mobile: +971 50 6996627

Email: adghal@eim.ae

73 of 74 Version 17.2.0
Contact Information
Sales Service
Mike Rodriguez Joe Colotta
Inside Sales Manager Operations Manager
info@hdigauges.com joe@hdigauges.com
Office: 713-688-8555 Mobile: 713-819-6103

Brian Harrington Joseph Ebenezer


Project Manager Service Manager
brian@hdigauges.com joseph@hdigauges.com
Mobile: 512-563-7604 Mobile: 713-446-2212

Shane Hulin
Project Manager
shane@hdigauges.com
Mobile: 337-368-5426

4130 Directors Row Houston, Texas 77092


713-688-8555

www.hdigauges.com

You might also like