Professional Documents
Culture Documents
Asas
Asas
NSCP 2015WIND LOAD CALCULATION FOR MAIN WIND FORCE RESISTING SYSTEM
Based on SECTION 207C
Section 207C discusses about Envelope Procedure for Enclosed & Partially Enclosed Low-Rise Buildings:
This Procedure is the former "low-rise buildings method" in NSCP 2010 (ASCE 7-05) Method 2.
This section also incorporates NSCP 2010 (ASCE7-05) Method 1 for MWFRS applicable to the MWFRS
of enclosed simple diaphragm building less than 18m in height
PARAMETERS
Wind Speed, V 150 kph
total height, z 8.85 m
height bottom of roof 6.6 m
horizontal dim. Parallel to wind dir., L 81 m
horizontal dim. Normal to wind dir., B 18 m
mean roof height , h 7.725 m
Roof Angle, θ 14 degrees
EXPOSURE C
Total Ht. above ground, z (m) α = 9.5
zg = 274.32
8.85 0.9755177431
EXPOSURE C
Mean Ht. above ground, z (m) α = 9.5
Mean Ht. above ground, z (m)
zg = 274.32
7.725 0.9479920436
A.2 Kzt = Topographic factor, Kzt, See Section 207 A.8 and Figure 207 A.8-1
= 1
A.3 Kd = Wind Directionality Factor , Kd, see Section 207 A.6 and Table 207 A.6-1
0.85
A.4 V = basic wind speed, V, for the applicable risk category See Figure 207 A.5-1A, B or C
41.666667 m/s
where:
qh = velocity pressure evaluated at mean roof height h using exposure defi
= 0.86 KPa
External Pressure Coefficient, GCpf on Low-Rise Walls & Roofs Enclosed, Partially Enclosed Buildings <= 18m,
(LOAD CASE A)
External Pressure Coefficient, GCpf on Low-Rise Walls & Roofs Enclosed, Partially Enclosed Buildings <= 18m,
(LOAD CASE B)
BUILDING SURFACE, LOAD CASE B
GCpi
1 2 3 4 5 6 1E 2E
0 -90 -0.45 -0.69 -0.37 -0.45 0.40 -0.29 0.48 -1.07
w-Rise Buildings:
o the MWFRS
3.2 •→
3.3 •→
3.4 •→
3.5 •→
(interpolated values)
CASE B
3E 4E 5E 6E
-0.53 -0.48 0.61 -0.43
3E 4E 5E 6E
-12.72 -11.82 7.70 -10.93
-6.27 -5.37 14.15 -4.48
3E 4E 5E 6E
-0.61 -0.57 0.37 -0.52
-0.30 -0.26 0.68 -0.21
PS TO DETERMINE WIND LOADS ON MWFRS
LOW-RISE BUILDINGS