Check the power connections to the RE2100, or check the internal power regulators.
21 The communication link between RE2100 and control unit C2140 or DSC/telex RM2150/
RM2151 has been stopped. Check the SP-BUS coax cable to the external equipment. If the
“Error 21” flashes up again after the button <STOP/ENT> has been pressed, then check the
SP-BUS interrupt line (J03-5 pin 6). This line has to be normal “High” (approx. +5V).
22 The communication link between the RE2100 and the Duplex/Telegraphy Receiver R2120T
has been stopped. Check the SP-BUS coax cable between these units.
Normally a fault in the ATU itself, but occasionally coursed by the Filter Board.
Please check the fuse F4 on the T2130 Connection Board.
71. VFORWARD LOW
The level of the Vforward voltage is low (< 0.7 Volt) measured at the output of the SWR detector
on the Output Filter (2).
SP-22-0 displays the latest measured Vforward.
The RF-signal is probably missing.
Check the RF-signal path from the Exciter Unit (4) in the RE2100 to the SWR Detector and the
Vforward path to the TX-processor.
Check output from RE2100 using the SP-05-0. The output from RE2100 module 8 has to be
3,8Vpp two-tone signal. Please check if a 10KΩ resistor is mounted across the output from
RE2100.
Check if the error 71 occurs on all frequency bands. If not, it is probably a fault in the Output
Filter.
If the output from the RE2100 is OK, use the SP-29 test program to trace the fault. This will
activate the transmitter on 1.6MHz Low Power, enabling you to measure the signal through the
system. Please refer to the diagrams test points and voltage values.
Normally coursed by antenna problem and/or Grounding problem. Specially grounding of the
AT2110 ATU is important. Please check if the four mounting plates of the AT2110 has a good
connection to ships ground (not corroded).
It is seen, that a fault in the AT2110 can give this error code.