Download as pdf or txt
Download as pdf or txt
You are on page 1of 816

Fiber Service Platform 3000R7

Module and System


Specification

Product Release 12.3


Document Issue A (March 2014)
Document Number 80000027945
Copyright © 2001-2014 ADVA Optical Networking SE
All rights reserved. Hardware and software mentioned in this document includes software developed
by ADVA Optical Networking SE ("ADVA Optical Networking"), the Apache Software Foundation
(http://www.apache.org), Teodor Danciu (http://jasperreports.sourceforge.net), and/or other open
source software. Some software was created using ORBacus for Java by Object-Oriented Concepts,
Inc.
Trademarks
The terms ADVA™ and FSP 3000® are trademarks or registered trademarks of ADVA Optical Network-
ing in the United States, Germany and/or other countries. All other company products or services men-
tioned in this document may be trademarks or service marks of ADVA Optical Networking or their
respective owner.
Patents
The content described in this document may be covered by patents or pending patent applications of
ADVA Optical Networking. The furnishing of this document does not give you any license to these pat-
ents.
Disclaimers
Nothing in this document shall be construed as granting any license or rights with respect to its content
or the patents and trademarks mentioned above. The content of this document may include technical
inaccuracies or typographical errors, and is subject to change at any time without notice. Reliance on
this content is at the relying party's sole risk and will not create any liability or obligation for ADVA Opti-
cal Networking. Any references in this document to publications and/or Internet sites that are not from
ADVA Optical Networking are provided for convenience only and do not in any manner serve as an
endorsement of those publications and/or Internet sites. The materials within those publications and/or
Internet sites are not part of the materials for any ADVA Optical Networking information, product, or
service, and use of those publications and/or Internet sites is at your own risk.
THE CONTENT OF THIS DOCUMENT IS PROVIDED ''AS IS'' AND ANY EXPRESSED OR IMPLIED
WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANT-
ABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL
ADVA OPTICAL NETWORKING, ITS AFFILIATES, EMPLOYEES, OFFICERS OR ITS SUPPLIERS
BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSE-
QUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE
GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
HOWEVER CAUSED AND BASED ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY
WAY OUT OF THE USE OF THIS DOCUMENT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
DAMAGE. THE SAME APPLIES FOR ANY HARDWARE OR SOFTWARE COVERED BY THIS DOC-
UMENT, UNLESS A SIGNED AGREEMENT WITH ADVA OPTICAL NETWORKING OR THE APPLI-
CABLE PRODUCT LIABILITY LAW EXPRESSLY STATES OTHERWISE.
ADVA Optical Networking SE
Fraunhoferstr. 9a
82152 Martinsried/Muenchen
Germany
Phone +49(0)89-890665-0
Fax +49(0)89-890665-199
http://www.advaoptical.com

2
Table of Contents
Related Documents Overview. . . . . . . . . . . . . . . . . . . . 13

Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Purpose and Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Publication History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Typographic Conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Safety Symbol and Message Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Obtaining Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
World Wide Web. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Documentation Disc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Ordering Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Documentation Feedback. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Obtaining Technical Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25


Customer Portal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Technical Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Contact ADVA Optical Networking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Acronyms and Abbreviations . . . . . . . . . . . . . . . . . . . . 27

Chapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . 55
Wavelength Plan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
DWDM Wavelengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
CWDM Wavelengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Defined Operating Network Wavelengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Interoperability of Channel Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
FEC Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Right to Use Versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Supported Shelf ID Range and Amount of Shelves per Node. . . . . . . . . . . . . . . . . . . . . . . . 62
Compliance Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
International . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
European Union . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
USA and Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

Module and System Specification 3


Jitter Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Module Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Latency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Optical Power Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

Chapter 2 Shelves and Components . . . . . . . . . . . . 69


SH9HU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
PSU/9HU-DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
PSU/9HU-AC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
FAN/9HU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
CEM/9HU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
SH7HU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
SH7HU-R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
PSU/7HU-DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
PSU/7HU-AC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
PSU/7HU-DC-HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
PSU/7HU-AC-HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
PSU/7HU-R-DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
PSU/7HU-R-DC-HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
PSU/7HU-AC-800. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
FAN/Plug-In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
SH1HU-HP/2DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
SH1HU-HP/E-TEMP/2DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
SH1HU-F/2DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
SH1HU-R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
SH1HU-R/PF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
PSU/1HU-R-AC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
PSU/1HU-R-AC-200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
PSU/1HU-R-DC-200. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
FAN/1HU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
SH1HU/PASSIVE/FT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
FMT/1HU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
OTDR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129

Chapter 3 Core Type Channel Modules . . . . . . . . . 133


WCC-PCTN-100GB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134

4 Module and System Specification


WCC-PCTN-100GA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
10TCC-PCTN-10G+100GB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
WCC-PCTN-10G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
4TCC-PCTN-2G7+10G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
10TCC-PCTN-4GUS+10G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
10TCC-PCN-2G7US+10G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
10WXC-PCN-10G. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
2WCC-PCN-10G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
2TWCC-PCN-2G7U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
WCC-PC1N-2G7U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227

Chapter 4 Access Type Channel Modules . . . . . . . 235


2PCA-PCN-10G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
10PCA-PCN-1G3+10G. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
2WCA-PCN-10G. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
4TCA-PCN-4GU+4G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
4TCA-PCN-4GUS+4G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
WCA-PCN-2G5U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Chapter 5 Enterprise Type Channel Modules. . . . . 273


WCE-PCN-100GB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274
WCE-PCN-100G. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282
10TCE-PCN-16GU+AES100G. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290
10TCE-PCN-10G+100G-GF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298
10TCE-PCN-10G+100G. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305
5TCE-PCTN-10GU+10G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313
5TCE-PCTN-10GU+AES10G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325
5TCE-PCTN-8GU+10GS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 337
5TCE-PCTN-8GU+AES10GS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 345
5TCE-PCN-10GU+10G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354
5TCE-PCN-10GU+AES10G. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364
4WCE-PCN-16GFC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374

Chapter 6 Pluggable Transceivers. . . . . . . . . . . . . 379


XFP/16GFC/#xxxxxL/SM/LC#Dxx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 382
XFP/16GFC/#19xxxL50/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384
XFP/11G/DCTV/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 386
XFP/11G/DCTLNR/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 388

Module and System Specification 5


XFP/11G/DCTLN/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390
XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev. 4.01) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 392
XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev. 5.01) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394
XFP/11G/#19xxxL50/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 396
XFP/OTN11G/#19xxxV/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 398
XFP/8G/#xxxxxL/SM/LC#Dxx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400
XFP/11G/CxxxxL/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402
XFP/11G/CxxxxV/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 404
XFP/8G/CxxxxL/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 406
XFP/10G/850I/MM/LC (HW Rev. 1.01) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 408
XFP/10G/850I/MM/LC (HW Rev. 2.01) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 409
XFP/11G/1310S/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 410
XFP/11G/1550L/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411
XFP/8G/1310S/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412
XFP/8G/850I/MM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413
SFP+/16GFC/1310S/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414
SFP+/16GFC/850I/MM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415
SFP+CDR/10GU/1550L/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 416
SFP+CDR/10GU/850I/MM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 417

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFP+CDR/11GU/1310S/SM/LC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 418
SFP+CDR/11GU/CxxxxL/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 420
SFP+CDR/11GU/CxxxxS/SM/LC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 422
SFP+/10G/1310S/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 424
SFP+/10G/850I/MM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 425
SFP+/11GU/#19xxxL50/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 426
SFP+/11GU/CxxxxL/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 428
SFP+/11GU/1310S/SM/LC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 430
SFP+/11GU/850I/MM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 431
SFP+/8GU/1310S/SM/LC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433
SFP+/8GU/850I/MM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 434
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 435
SFP/4GU/CxxxxV/SM/LC (HW Rev. 2.01). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 436
SFP/4GU/CxxxxV/SM/LC (HW Rev. 3.01). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 437
SFP/4GU/1310S/SM/LC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 438
SFP/4GU/850I/MM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 439
SFP/4GU/CxxxxL/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 440
SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 442
SFP/2G5U/CxxxxV/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 444
SFP/2G5U/CxxxxL/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 446

6 Module and System Specification


SFP/2G5U/1310S/SM/LC (HW Rev. 2.01). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 447
SFP/2G5U/1310L/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 448
SFP/3GSDI/#xxxxxV/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 449
SFP/3GSDI/ELECTRICAL/DIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 451
SFP/3GSDI/ELECTRICAL/HBNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 452
SFP/HS/1310S/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 453
SFP/CL/1310I/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 454
SFP/2G1/850I/MM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 455
SFP/GBE/1310S/SM/LC/TIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 457
SFP/GBE/1310L/SM/LC/TIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 458
SFP/GBE/1550V/SM/LC/TIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 459
SFP/GBE/850I/MM/LC/TIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 460
SFP/GBE/B1310S/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 461
SFP/GBE/B1490S/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 462
SFP/GBE/B1310L/SM/LC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 463
SFP/GBE/B1490L/SM/LC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 464
SFP/GBE/Electrical/RJ45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 465
SFP/FE/C1490U/SM/LC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 466
SFP/FE/C1510U/SM/LC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 467
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

SFP/FE/C1490V/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 468
SFP/FE/C1510V/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 469
SFP/FE/D1528.77E/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 470
SFP/FE/Dxxxx.xxV/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 471
CFP/112G/LR10R/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 472
CFP/112G/LR4/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 475
CFP/103G/SR10/MM/MPO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 478
CFP/4x28G/#19xxx-#19xxxL/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 480
CFP/4x28G/#DCTL/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 483

Chapter 7 Management and Switch Modules . . . . 487


NCU-II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 488
NCU-II-P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 490
UTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 492
PSCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 494
SCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 495
SCU-II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 497
SCU-S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 499
VSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 501
RSM-OLM#1630. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 503

Module and System Specification 7


OSCM-PN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 505

Chapter 8 Reconfigurable Optical Layer Devices . 509


ROADM-C80/0/OPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 510
8ROADM-C40/0/OPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 516
8ROADM-C80/0/OPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 521
9ROADM-C96/0/OPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 526
4ROADM-C96/0/OPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 532
CCM-C40/8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 537
CCM-C80/8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 541
CCM-C96/9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 545
4-OPCM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 550

Chapter 9 Optical Filter Modules . . . . . . . . . . . . . . 553


ILM50-#DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 555
2CLSM-#D01-#D64 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 557
40CSM/2HU-#Dxx-#Dyy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 558
40CSM/2HU-#19590-#19200. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 560

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
40CSM/2HU-#19595-#19205. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 562
40CSM-FL/2HU-#19590-#19200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 564
40CSM-C80/2HU-#19xxx-#19yyy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 566
40CSM/P-2HU#19590-#19200-DM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 568
96CSM/4HU-#19600-#19125. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 570
2BSM-#D01-#D32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 572
4GSM-#Dxx-#Dyy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 574
8GSM-#D01-#D32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 576
1GSM+#Dxx-#Dyy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 578
5GSM-#19590-#19200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 580
8CSM-#19xxx-#19yyy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 582
4CSM+#19xxx-#19yyy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 585
4CSM-#Dxx-#Dyy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 587
4CSM+#Dxx-#Dyy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 589
1CSM+#Dxx-E/W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 591
1CSM+#19xxx-E/W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 593
2CLSM-#D01-#D64-SFx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 595
16CSM-#D01-#D32-SFx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 597
16CSM-#D33-#D64-SFx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 599
OSFM+#1490-SFA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 601

8 Module and System Specification


OSFM+#1510-SFB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 603
2ABSM-#C1470-#C1610 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 605
3BSM-#G1310-#C1610 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 607
4CSM-#Cxxxx-#Cyyyy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 609
8CSM+#C1470-#C1610 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 611
1CSM+#G1310 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 614
1CSM+#Cxxxx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 616
5GSM/P-#19590-#19200-DM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 618
8CSM/P-#C1470-#C1610-DM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 620
2BSM/P-#C1270-#C1610-DM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 622
8CSM/P+#C1470-#C1610-DM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 624
8CSM/P-#19xxx-#19yyy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 626
8CSM/P-#C1270-#C1450. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 629
1CSM/P+#Cxxxx. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 631
OSFM+#1510 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 633
2-OTFM+#1650 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 635
5PSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 637
8PSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 638
PSM-95/5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 640
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

2PSM-95/5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 641
1PM/SM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 643
1PM/MM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 644
2PM/SM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 645
2PM/MM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 646
Y-Cable/SM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 647
Y-Cable/MM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 649
J/SM/4CS-#C1270-#C1330/LC/0400. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 651

Chapter 10 Optical Amplifiers . . . . . . . . . . . . . . . . . 653


EDFA-C-D17-GC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 654
EDFA-L-D17-GC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 657
EDFA-C-S20-GCB-DM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 660
EDFA-C-D20-VGC-DM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 663
EDFA-C-D20-VLGC-DM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 667
EDFA-C-S26-VGC-DM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 671
EDFA-C-S26-VGCB-DM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 675
RAMAN-C10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 679
2RAMAN-C15-LL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 684
AMP-S20H-C15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 692

Module and System Specification 9


AMP-S20L-C15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 699
EDFA-S20H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 706
EDFA-S20L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 711
2EDFA-S20L-S10L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 716

Chapter 11 Dispersion Compensation Modules . . . . 723


DCF-M/xxx/SSMF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 724
DCG-M/xxx/SSMF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 727
DCG50-M/xxx/SSMF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 729
DCG-M/xxx/TWRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 731
DCG50-M/xxx/TWRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 733
DCF1HU-P Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 735

Appendix A Overview of Modules . . . . . . . . . . . . . . 741


Client and Network Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 743
DWDM Modules - Channel Grid Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 746
Pluggable Interfaces - Channel Grid Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 747
Optical Amplifiers - Channel Grid Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 747

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ROADM Supported Channel Modules and Amplifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 748
CCM Supported Channel Modules and Amplifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 750
ROADM Compatible Pluggable Transceivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 752
CCM Compatible Pluggable Transceivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 753
Loop Functionality Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 753
Channel Module Protection Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 755
Channel Module Regeneration Capabilities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 758
Data Rates and Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 761
Channel Module Services. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 763
Channel Module Data Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 767
Channel Module In-band Management Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 771
Channel Module Error Signaling on Client Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 774
Pluggable Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 775
XFP/SFP/CFP Gray Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 775
XFP/SFP/CFP Colored Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 779
Assignment of Pluggable Transceivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 781
XFPs at the Client Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 781
XFPs at the Network Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 782
SFPs at the Client Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 783
SFPs at the Network Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 786

10 Module and System Specification


CFPs at the Client Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 787
CFPs at the Network Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 787

Appendix B Use of DCM with Doublestage EDFA . . . 789

Appendix C History of Changes . . . . . . . . . . . . . . . . 791


Releases 8.1.1 through 9.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 791
Release 12.1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 805
Release 12.2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 811
Release 12.3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 815
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 11


12
Module and System Specification
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Related Documents Overview
Refer to these documents when planning, installing, provisioning, operating,
troubleshooting, and working with FSP 3000R7 equipment and management
tools:

Planning
• Planning and Engineering Guide
This is a reference document. Part I describes the architecture and
principles behind major features such as transport protocols, protection,
optical amplification, reconfigurable OADMs, DCN, control plane, and
management-related features.

Part II describes physical details about each module such as front plate
pictures and markings, signal path description with block diagrams, and
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

allowed placement and labeling of the modules. For details related to the
supported configurations of each module, parameter values, and other
management related data, refer to the Management Data Guide.

Starting with Release 11.2, the Planning and Engineering Guide


PS

replaces the Detailed System Description, Deployment Rules, and


Hardware Description.
Note

• Module and System Specification


This document contains the technical specifications for the FSP 3000R7.

Installing
• Critical Warnings
This document lists the most important safety requirements as well as input
power restrictions for channel modules and pluggable transceivers. Read
this document before installing, provisioning, configuring or operating the
FSP 3000R7.
• Safety Guide
This document describes important safety precautions that are to be read
and observed before attempting to install, provision, configure or operate
the FSP 3000R7. Therefore, read this document first.

Module and System Specification 13


• Shipment Contents
This document is used to check and verify the contents of each shipping
box against the original purchase order.
• Installation and Commissioning Manual
This document includes procedures describing how to install an
FSP 3000R7 node. It covers everything from unpacking the shipment,
rack-mounting the equipment, connecting optical fibers, and includes basic
commissioning.
• OTDR Installation, Provisioning, and Operations Manual
This document covers installation, provisioning, operations,
troubleshooting, and maintenance of the OTDR unit.

Provisioning and Operating


• Network Element Director Online Help
This document describes how to provision, operate, and monitor the
FSP 3000R7 system using Network Element Director. For detailed
information about configuration and management options, refer to the
Management Data Guide.
• Provisioning and Operations Manual
This document contains procedures for provisioning, operating, and
monitoring the FSP 3000R7 system. Refer the Management Data Guide

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
while following the procedures in the Provisioning and Operations Manual to
look up provisioning and management-related details.
• Management Data Guide
This document contains all provisionable and read-only parameters for
each module, as well as the performance counters for the modules. This is
a useful reference both when planning and engineering a network and while
following the instructions in the management tool procedural
documentation.
• OTDR Installation, Provisioning, and Operations Manual
This document covers installation, provisioning, operations,
troubleshooting, and maintenance of the OTDR unit.

Working with Management Tools


• TL1 Commands and Syntax Guide
This document describes the TL-1 commands available to provision,
configure, operate, and monitor the FSP 3000R7.
• TL1 Module Parameters Guide
This document provides reference information about all TL1-based
provisioning and performance monitoring options for the FSP 3000R7
modules, as well as the conditions for them.

14 Module and System Specification


Troubleshooting
• Maintenance and Troubleshooting Manual
This document describes how to troubleshoot the FSP 3000R7 hardware
and software.
• TL-1 Maintenance and Troubleshooting Manual
This document describes how to troubleshoot the FSP 3000R7 when
managing it by using TL-1.
• OTDR Installation, Provisioning, and Operations Manual
This document covers installation, provisioning, operations,
troubleshooting, and maintenance of the OTDR unit.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 15


16
Module and System Specification
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Preface
The Preface gives general information for the effective use of the Fiber Service
Platform (FSP 3000R7) Module and System Specification.
This publication is provided "as is" without express or implied warranty for
accuracy and completeness.

Purpose and Scope


The purpose of this documentation is to provide module and system
specifications for the FSP 3000R7 Release 11.2.
For an overview of the supported modules and features of Release 11.2, please
refer to the Release Notes.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

In this specification, you can find short function descriptions and detailed
technical data. This is the correct reference if you are planning an optical
network containing FSP 3000R7 components.
This document lists the fault cause persistency filtered (FCPF) conditions for
each module in the corresponding fault monitoring tables. Please refer to the
Planning and Engineering Guide for more information about FCPF conditions.

Audience
This documentation is primarily intended to be read by any persons who need
details on technical data and short function descriptions of the supported
modules.

Module and System Specification 17


Publication History
For an overview of the content of any one product release, please refer to the
Appendix C: History of Changes of this document or to the Release Notes
provided with your system.

Product Document Document


Issue Date Description
Release Number Version
8.3 80000003764 Issue A February 2009 For details see 
Issue B March 2009 Appendix C: History of Changes
Issue C March 2009
Issue D April 2009
Issue E September 2009
9.1 80000003768 Issue A June 2009 For details see 
Issue B July 2009 Appendix C: History of Changes
Issue C August 2009
Issue D September 2009
Issue E October 2009
Issue F November 2009
9.2 80000008781 Issue A November 2009 For details see 
Issue B December 2009 Appendix C: History of Changes

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Issue C February 2010
9.3 80000010623 Issue A March 2010 For details see 
Issue B May 2010 Appendix C: History of Changes
Issue C May 2010
Issue D July 2010
Issue E August 2010
10.1 80000011726 Issue A September 2010 For details see 
Issue B Appendix C: History of Changes
Issue C
Issue D
Issue E January 2011
10.2 80000014010 Issue A October 2010 For details see 
Issue B December 2010 Appendix C: History of Changes
Issue C March 2011
Issue D April 2011
10.3 80000014672 Issue A May 2011 For details see 
Issue B July 2011 Appendix C: History of Changes
Issue C October 2011
11.1 80000015933 Issue A March 2012 For details see 
Issue B April 2012 Appendix C: History of Changes
Issue C June 2012

18 Module and System Specification


Product Document Document
Issue Date Description
Release Number Version
11.2 80000020928 Issue A September 2012 For details see 
80000020928 Issue B January 2013 Appendix C: History of Changes
80000020928 Issue C May 2013
12.1 80000024438 Issue A August 2013 For details see 
80000024438 Issue B October 2013 Appendix C: History of Changes
80000024438 Issue C November 2013
12.2 80000026935 Issue A December 2013 For details see 
80000026935 Issue B January 2014 Appendix C: History of Changes
80000026935 Issue C February 2014
12.3 80000027945 Issue A March 2014 For details see 
Appendix C: History of Changes

Organization
This documentation is organized as follows:

Preface
Describes the purpose, audience, organization and the conventions, that are
used throughout this documentation. In addition, important ADVA Optical
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Networking (ADVA) contact details, EMC, Laser Safety and Compliance


Statements as well as further useful information are provided.

Acronyms and Abbreviations


This section contains the acronyms, abbreviations and symbols used
throughout this documentation. The terms and their spelled out forms or their
meaning are listed in alphabetical order.

Chapter 1: Introduction
This chapter provides an overview of the wavelengths used for the Fiber Service
Platform (FSP 3000R7) and gives information about the defined operating
network wavelengths, FEC codes, equipment disposal, power consumption
values, conformance of laser products and EMC classification.

Chapter 2: Shelves and Components


This chapter provides short function descriptions and detailed technical data of
the various shelves that comprise the FSP 3000R7, such as the 1HU Shelf, 7HU
Shelf, 9HU Shelf and the DCM Shelf. In addition, the OTDR as a standalone unit
is described. Detailed information about the power supplies and the fan unit are
also provided.

Chapter 3: Core Type Channel Modules


This chapter provides short function descriptions and detailed technical data of
all core type channel modules available.

Module and System Specification 19


Chapter 4: Access Type Channel Modules
This chapter provides short function descriptions and detailed technical data of
all access type channel modules available.

Chapter 5: Enterprise Type Channel Modules


This chapter provides short function descriptions and detailed technical data of
all enterprise type channel modules available.

Chapter 6: Pluggable Transceivers


This chapter provides short function descriptions and detailed technical data of
the pluggable transceiver types used by the FSP 3000R7 channel modules.

Chapter 7: Management and Switch Modules


This chapter gives short function descriptions and detailed technical data of the
management modules, the optical supervisory channel modules and the optical
protection switch modules available.

Chapter 8: Reconfigurable Optical Layer Devices


This chapter gives short function descriptions and detailed technical data of the
reconfigurable optical layer devices available.

Chapter 9: Optical Filter Modules

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This chapter provides short function descriptions and detailed technical data of
the various types of passive optical modules, such as channel splitter modules
(CSMs), group splitter modules (GSMs), band splitter modules (BSMs), optical
supervisory filter module (OSFM) and protection modules (PMs) available.

Chapter 10: Optical Amplifiers


This chapter provides short function descriptions and detailed technical data of
the fixed pump power Erbium-Doped Fiber Amplifiers and the gain-controlled
Erbium-Doped Fiber Amplifier types as well as the Raman fiber amplifier
available.

Chapter 11: Dispersion Compensation Modules


This chapter gives short function descriptions and detailed technical data of the
Dispersion Compensation Modules (DCMs) used by the FSP 3000R7.

Appendix A: Overview of Modules


Appendix A contains tables with general information about channel modules as
well as their relationships to each other as an overview. An overview of
pluggable transceivers is also provide.

Appendix B: Use of DCM with Doublestage EDFA


Appendix B provides general information about the use of DCM modules with
doublestage optical amplifiers.

20 Module and System Specification


Appendix C: History of Changes:
Appendix C lists significant changes (additions, corrections, etc.) made in the
separate issues of this documentation.

Document Conventions
This section lists the common typographical and symbol use for FSP 3000R7
documents.

Typographic Conventions
The documentation follows these typographic conventions:

Convention Description
boldface font Indicates keywords and emphasized words when
appearing in main text areas. All warnings are in
boldface font.
blue font Indicates a reference to a chapter, section, figure,
table or related documentation when appearing in
main text areas.
CAPITALIZED font Refers to the keys on your keyboard, e.g. ENTER
marked 
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

courier Courier font is used to identify words that can be


read from or typed into the command line interface.
[] Elements in square brackets are optional.
| Alternative elements are separated by a vertical
bar.
^ The symbol ^ represents the key labeled Control -
for example, the key combination ^D means that
you have to hold down the Control key while you
press the D key.
< > References are enclosed in angle brackets, for
example:
<Esc> The escape key, marked Esc
<Enter> The Enter key, marked 
<username> This reference, including the angle
brackets, is replaced by the appropriate user name.
Nonprinting characters, such as passwords.
“” Double inverted commas are used to enclose
quoted text.
• (bullet symbol) Used in bulleted list of items where the sequence of
items is not relevant.
1, 2, 3 ...or These numbering styles are used in lists of items
a), b), c)... where the sequence of items is relevant.

Module and System Specification 21


Convention Description
* or 1, 2 etc. These are used to point to table footnotes. The
markers in the text are arranged as continuous
superscript numbers. Footnote text (in smaller
typeface) is placed at the bottom of a table and
starts with a superscript number.
-> Refers you to additional information.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

22 Module and System Specification


Safety Symbol and Message Conventions
The safety alert symbols with the appropriate signal words and the note signs
below are used throughout this documentation to identify warnings, cautions
and notes.

This symbol accompanies any instruction that draws attention to


the risks caused by electricity. These risks could result in death or
serious injury if the instruction is ignored or not followed correctly.
WARNING

This symbol accompanies any instruction that draws attention to


a potentially hazardous situation/condition. This
situation/condition, may result in minor or moderate injury, if the
CAUTION instruction is ignored or not followed correctly.

This symbol accompanies any instruction that draws attention to


the risk of possible laser radiation. This risk may result in serious
eye injury, if the instruction is ignored or not followed correctly.
CAUTION

This symbol accompanies any instruction that draws attention to


the possibility of equipment damage due to electrostatic
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

discharge (ESD). Damage can occur, if the ESD-prevention


instructions are ignored or not followed correctly.

This symbol accompanies any instruction that draws


attention to the risk of equipment damage, malfunction,
NOTICE process interruption or negative impacts on surroundings.
These events can occur, if the instruction is ignored or not
followed correctly.

A symbol that draws attention to the necessity and importance of


carefully reading all instructions before any installation or
operation takes place. Failure to do so may result in personal
injury or damage to equipment.

This symbol accompanies any instruction that draws attention to


the proper disposal of waste electrical or electronic equipment
and its components. Disregard of the instruction can threaten the
environment.

This symbol accompanies any statement, supplemental


PS

information or helpful recommendation that should be observed.


Note

Module and System Specification 23


Obtaining Documentation
World Wide Web
You can access the most current ADVA Optical Networking documentation on
the World Wide Web via the Customer Portal at:
http://www.advaoptical.com/
Contact your ADVA Optical Networking sales representative for details.

Documentation Disc
The FSP 3000R7 User Documentation Suite is available on the disc that is
delivered with the product. The disc also contains the USB driver required for
establishing a USB serial connection.

Ordering Documentation
ADVA Optical Networking customers can order the FSP 3000R7 User
Documentation Suite and additional literature through a local ADVA Optical
Networking sales representative. For more current product release information,
please refer to the home page, or contact the Technical Services of ADVA
Optical Networking. See “Obtaining Technical Assistance” on p. 25 and
“Contact ADVA Optical Networking” on p. 26 for contact details.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Documentation Feedback
We want our FSP 3000R7 documentation to be as helpful as possible.
Feedback regarding the guide is therefore always welcome.
You can e-mail your comments/suggestions to:
global-techdocu@advaoptical.com
To submit your comments/suggestions by mail, use the following address:
ADVA Optical Networking SE
Technical Documentation
Maerzenquelle 1-3
98617 Meiningen-Dreissigacker
Germany
We appreciate and value your comments/suggestions to improve the quality of
the guide.

24 Module and System Specification


Obtaining Technical Assistance
Product Maintenance Agreements and other customer assistance agreements
are available for ADVA Optical Networking products through your ADVA Optical
Networking distribution channel. Our service options include:
• 24 x 7 telephone support
• Web-based support tools
• On-site support
• Technical training, both on-site and at ADVA Optical Networking facilities in
Germany and the USA
• Expedited repair service
• Extended hardware warranty service

Customer Portal
The ADVA Optical Networking Customer Portal provides a suite of interactive,
networking services that provide immediate access to company information and
resources at any time, from anywhere in the world. This highly integrated
internet application is a powerful, easy-to-use tool for doing business with ADVA
Optical Networking.
The broad range of features and services provided by the portal help customers
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

and partners to streamline business processes and improve productivity.


Through the customer login, you will find information tailored especially for you,
including networking solutions, services, and programs. In addition, you can
resolve technical issues with online support services, download and test
software packages, and order ADVA Optical Networking training materials.
Access the Customer Portal via the ADVA Optical Networking home page at:
http://www.advaoptical.com/en/customer-portal.aspx
E-mail questions regarding the Customer Portal to:
customer-portal-admin@advaoptical.com

Technical Services
Technical services are available to warranty or maintenance contract customers
who need technical assistance with a product from ADVA Optical Networking
that is under warranty or covered by a maintenance contract. To access
Technical Services, including all contact information, go to the ADVA Optical
Networking home page at:
http://www.advaoptical.com

Module and System Specification 25


Obtaining Technical Assistance

To contact ADVA Optical Networking by E-mail, use one of the following


addresses:

Europe, Middle East, Africa:


Support@advaoptical.com

Americas:
Support-Americas@advaoptical.com

Asia Pacific:
SAsia@advaoptical.com

Contact ADVA Optical Networking


ADVA Optical Networking Europe, Middle East and Africa
Martinsried/Munich, Germany
+49 (0)89 89 06 65 0
info@advaoptical.com

ADVA Optical Networking America


Norcross, GA, USA

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
+1 687 728 8600
info@advaoptical.com

ADVA Optical Networking Asia


Shenzhen, China
+86 755 8621 7400
info@advaoptical.com

www.advaoptical.com

26 Module and System Specification


Acronyms and Abbreviations
This section contains the acronyms, abbreviations and symbols used in the
Module and System Specification. The terms and their spelled out forms or their
meaning are listed in alphabetical order.

Symbols/Numerics
°C degree Celsius
°F degree Fahrenheit
10 GbE 10 gigabit Ethernet
10 GbE LAN 10 gigabit Ethernet used in Local Area Network
10 GbE LAN PHY 10 gigabit Ethernet LAN physical layer
10 GbE WAN 10 gigabit Ethernet used in Wide Area Network
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

10 GbE WAN PHY 10 gigabit Ethernet WAN physical layer


1000BASE-T 1000 Mbit/s over twisted pair Cat 5e cable
100BASE-TX 100 Mbit/s over twisted pair Cat 5e cable (an Ethernet
standard IEEE 802.3)
10BASE-T 10 Mbit/s over twisted pair Cat 5 cable (an Ethernet
standard IEEE 802.3)
10G 10 gigabit
10G FC 10 gigabit Fibre Channel
10G IB 10 gigabit Infiniband
10PCA-PCN-1G3+10G 10PCA-PCN-1G3+10G is a 12-port packet channel access
module with ten 1 GbE client SFP and two 10 GbE network
XFP type pluggable interfaces.
10TCC-PCN-2G7US+10G Core type 10-port ADM channel module with ten client and
two network pluggable interfaces; up to eight GbE
services on the client interface if one network interface is
configured and up to ten GbE services with two network
interfaces configured
10TCC-PCTN-10G+100GB 100G Core type 10-port TDM channel module
(muxponder) with ten SFP+ interfaces on the client side
and an integrated single DWDM interface on the network
side; network interface is fully tunable over the C band at
50 GHz channel spacing; the client interfaces support
10GbE WAN, STM64/OC192, 10GbE LAN, OTU2, OTU2e
and OTU1e services; network data rate for OTU4 protocols

Module and System Specification 27


10TCC-PCTN-4GU+10G Core type 10-port TDM channel module with ten pluggable
interfaces on the client side and one integrated 10 Gigabit
DWDM interface on the network side that is fully tunable in
the C or L band; the client interfaces support 1GbE, 1GFC,
2GFC and 4GFC services; module is available in four
variants (collective name)
10TCC-PCTN-4GU+10G-LN#DC core type 10-port 10G TDM channel module with ten
pluggable interfaces on the client side and one 10G long
reach link, 50 GHz-spaced tunable DWDM interface on the
network side; for the use in the C band of the DWDM
transport system. client data rate of 1.25 Gbit/s, 
1.0625 Gbit/s, 2.125 Gbit/s or 4.250 Gbit/s; aggregated
data rate on the network port of 10 Gbit/s
10TCC-PCTN-4GU+10G-V#DC core type 10-port TDM channel module with ten pluggable
interfaces on the client side and one integrated, very-long
reach link distance, tunable DWDM interface on the
network side; support of 81 C-band channels at 50 GHz;
maximum client data rate of 4.25 Gbit/s; aggregated data
rate on the network port of 10 Gbit/s
10TCC-PCTN-4GU+10G-V#DL core type 10-port TDM channel module with ten pluggable
interfaces on the client side and one integrated, very-long
reach link distance, tunable DWDM interface on the
network side; support of 41 L-band channels at 100 GHz;
maximum client data rate of 4.25 Gbit/s; aggregated data

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
rate on the network port of 10 Gbit/s
10TCC-PCTN-4GUS+10G Core type 10-port TDM channel module with ten pluggable
interfaces on the client side and one integrated 10 Gigabit
DWDM interface on the network side that is fully tunable in
the C or L band; the client interfaces support GbE, 1GFC,
2GFC, 4GFC, STM-1/OC-3, STM-4/OC-12 and
STM-16/OC-48 services; module is available in three
variants (collective name)
10TCC-PCTN-4GUS+10G-LN#DC Core type 10-port TDM channel module with ten pluggable
interfaces on the client side and one integrated, 10 G long
reach link, noise optimized 50 GHz-spaced tunable DWDM
interface on the network side; support of C-band channels
only; client port data rates between 155.52 Mbit/s and
4.2500 Gbit/s; maximum aggregated data rate on the
network port of 10.7 Gbit/s
10TCC-PCTN-4GUS+10G-V#DC Core type 10-port TDM channel module with ten pluggable
interfaces on the client side and one integrated, 10G very
long reach link, 50 GHz-spaced tunable DWDM interface
on the network side; support of C-band channels only;
client port data rates between 155.52 Mbit/s and
4.2500 Gbit/s; maximum aggregated data rate on the
network port of 10.7 Gbit/s

28 Module and System Specification


10TCC-PCTN-4GUS+10G-V#DL Core type 10-port TDM channel module with ten pluggable
interfaces on the client side and one integrated, 10G very
long reach link, 100 GHz-spaced tunable DWDM interface
on the network side; support of L-band channels only;
client port data rates between 155.52 Mbit/s and
4.2500 Gbit/s; maximum aggregated data rate on the
network port of 10.7 Gbit/s
10TCE-PCN-10G+100G 100G Enterprise type TDM channel module with ten SFP+
interfaces on the client side (10x10G) and a single CFP
interface on the network side; aggregate network date rate
of 111.81Gb/s (according to OTU-4 G.709); enhanced
FEC (EFEC)
10TCE-PCN-10G+100G-GF 100G Enterprise type TDM channel module with ten SFP+
interfaces on the client side (10x10G) and a single CFP
interface on the network side; aggregate network date rate
of 111.81Gb/s (according to OTU-4 G.709); G.709
standard FEC (GFEC)
10TCE-PCN-16GU+AES100G 100G Enterprise type TDM channel module with ten
SFP(+) interfaces on the client side and a single CFP
interface on the network side; supports encrypting of
100Gbit/s on the network interface; maximum client data
rate of 14.025 Gbit/s; aggregated data rate on the network
port of 111.81 Gbit/s (according to OTU-4 G.709); two slots
wide module
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

10WXC-PCN-10G 10 x 10G ODU-Cross-Connect module with 100G capacity


providing ten XFP interfaces; supports cross-connect of
ODU2, ODU2e, ODU1 and ODU0s between OTU2/2e
ports in accordance with ITU-T G.709 as well as mapping
10G-LAN into OTN
16CSM-#D01-#D32-SFA 16-port channel splitter module - single-fiber working - C
band, location A
16CSM-#D01-#D32-SFB 16-port channel splitter module - single-fiber working - C
band, location B
16CSM-#D01-#D32-SFx 16-port channel splitter module - single-fiber working - C
band (short form for 16CSM-#D01-#D32-SFA and
16CSM-#D01-#D32-SFB)
16CSM-#D33-#D64-SFA 16-port channel splitter module - single-fiber working - L
band, location A
16CSM-#D33-#D64-SFB 16-port channel splitter module - single-fiber working - L
band, location B
16CSM-#D33-#D64-SFx 16-port channel splitter module - single-fiber working - L
band (short form for 16CSM-#D33-#D64-SFA and
16CSM-#D33-#D64-SFB)
16G FC 16 gigabit fibre channel (a network technology working at a
line rate of 14.025 Gbit/s)
1CSM/P+#Cxxxx passive optical single channel CWDM splitter and
combiner module with upgrade port; it adds/drops a
specific channel to/out of the CWDM channel spectrum

Module and System Specification 29


1CSM+#19xxx-E/W east/west single channel DWDM splitter and combiner
module with upgrade port; it adds/drops a specific channel
to/out of the DWDM channel spectrum #19560-#19240
1CSM+#Cxxxx single channel CWDM splitter module with upgrade port; it
adds/drops a specific channel to/out of the CWDM channel
spectrum
1CSM+#Dxx-E/W east/west single channel DWDM splitter module with
upgrade port; it adds/drops a single channel to/out of the
DWDM channel spectrum
1CSM+#G1310 single channel CWDM splitter module with upgrade port
and gray interface at 1310 nm; it adds/drops the
broadband 1310 nm channel to/out of the CWDM/DWDM
channel spectrum
1G 1 gigabit
1G CL 1 gigabit Coupling Link
1G FC 1 gigabit Fibre Channel (a network technology working at a
line rate of 1.0625 Gbit/s)
1GbE 1 gigabit Ethernet (a technology for transmitting Ethernet
packets at a rate of 1 Gbit/s)
1GSM+#Dxx-#Dyy 1-port DWDM group splitter module with upgrade port - C
band (collective name)
1HU Shelf 1 HU-high equipment shelf
1PM/MM single-port protection module multimode

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
1PM/SM single-port protection module single-mode
2-OTFM+#1650 optical time-domain reflectometer filter module with
upgrade port, OTDR wavelength at 1650 nm
2.5G 2.5 gigabit
2ABSM-#C1470-#C1610 2-port CWDM subband splitter module (It splits the 8
CWDM channels into two groups of 4 channels each and
vice versa.)
2BSM-#D01-#D32 2-port DWDM red/blue splitter module - C band
2BSM/P-#G1310-#C1610-DM passive 2-port CWDM band splitter module with gray
interface at 1310 nm and monitoring port for dual power
level monitoring
2CLSM C-band/L-band splitter (short form for 2CLSM-#D01-#D64
or 2CLSM-#D01-#D64-SFx)
2CLSM-#D01-#D64-SFA DWDM 2-port C/L band splitter module - single-fiber
working, location A
2CLSM-#D01-#D64-SFB DWDM 2-port C/L band splitter module - single-fiber
working, location B
2CLSM-#D01-#D64-SFx DWDM 2-port C/L band splitter module - single-fiber
working (collective name)
2EDFA-S20L-S10L dual optical amplifier module with 20dB and 10dB EDFAs;
supports 96 C-band channels, 15 to 30 dB span loss, OSC
filter and level control, Fiber Map Detection
2G CL 2 gigabit Coupling Link
2G FC 2 gigabit Fibre Channel (a network technology working at a
line rate of 2.125 Gbit/s)

30 Module and System Specification


2PCA-PCN-10G 4-port packet channel access module with two 10 GbE
client XFP and two 10 GbE network XFP type pluggable
interfaces
2PM/MM 2-port protection module multimode
2PM/SM 2-port protection module single-mode
2PSM-95/5 2-way power splitter module 95%/5%
It separates 5% of optical power from the received and
transmitted signals for power monitoring and optical
spectrum analyzing.
2R reshaping and reamplifying (signal regeneration)
2RAMAN-C15-LL full C-band dual fiber Raman amplifier module which
provides up to 30 dB of Raman gain in a G.652, G.653,
G.655 and other fiber types and which is optimized for use
in low latency networks
2TWCC-PCN-2G7U core type 2-port WDM channel module with two pluggable
client and two pluggable network interfaces; can operate
as a transponder or as a multiplexer; maximum client and
network data rate of 2.7 Gbit/s
2WCA-PCN-10G access type, 2-port multirate 10G WDM channel module
with two pluggable client and two pluggable network
interfaces
2WCC-PCN-10G core type WDM channel module with two pluggable client
interfaces and two pluggable network interfaces; client and
network port data rates from 9.9532 Gbit/s to 11.0957
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Gbit/s
3BSM-#G1310-#C1610 CWDM band splitter module with gray interface at 1310 nm
3R reshaping, reamplifying and retiming (signal regeneration)
4-OPCM 4-port Optical Power Control Module; the module has
VOAs (Variable Optical Attenuators) managed by the
NE-SW as alternative to pluggable fixed attenuators
40CSM-C80/2HU-#19590-#19200 40-port MUX/DMX channel splitter/combiner 2HU shelf -
even C band channels, used for dual client configuration
with the 8ROADM-C80/0/OPM
40CSM-C80/2HU-#19595-#19205 40-port MUX/DMX channel splitter/combiner 2HU shelf -
odd C-band channels, used for dual client configuration
with the 8ROADM-C80/0/OPM
40CSM-C80/2HU-#19xxx-#19yyy 40-port MUX/DMX channel splitter/combiner 2HU shelf -
C-band channels, used for dual client configuration with
the 8ROADM-C80/0/OPM (collective name)
40CSM-FL/2HU-#19590-#19200 40-port MUX/DMX channel splitter/combiner 2HU shelf -
even C band channels for signal transport and for fibers
going to the left side
40CSM/2HU-#19590-#19200 40-port MUX/DMX channel splitter/combiner 2HU shelf -
even C band channels and for fibers going to the right side
40CSM/2HU-#19595-#19205 40-port MUX/DMX Channel Splitter and Combiner 2HU
Shelf for 50-GHz interleaved C-band channels
40CSM/2HU-#D02-#D32 40-port MUX/DMX Channel Splitter 2HU Shelf - C band
40CSM/2HU-#D02-#D32 40-port MUX/DMX Channel Splitter 2HU Shelf - C band
40CSM/2HU-#D34-#D64 40-port MUX/DMX Channel Splitter 2HU Shelf - L band

Module and System Specification 31


40CSM/2HU-#D34-#D64 40-port MUX/DMX Channel Splitter 2HU Shelf - L band
40CSM/2HU-#Dxx-#Dyy 40-port MUX/DMX Channel Splitter 2HU Shelf - C or L
band (collective name)
40CSM/2HU-#Dxx-#Dyy 40-port MUX/DMX Channel Splitter 2HU Shelf - C or L
band (collective name)
40CSM/P-2HU#19590-#19200-DM passive 40-port MUX/DMX channel splitter and combiner
2HU shelf with monitoring port for dual power level
monitoring
4CSM-#Cxxxx-#Cyyyy 4-port CWDM channel splitter module - subband
#C1470-#C1610 or #C1510-#C1590 (collective name)
4CSM-#Dxx-#Dyy 4-port DWDM channel splitter module - C band (collective
name)
4CSM+#19xxx-#19yyy 4-port DWDM channel splitter and combiner module with
upgrade port - C band (collective name)
4CSM+#Dxx-#Dyy 4-port DWDM channel splitter module with upgrade port -
C band (collective name)
4G 4 Gigabit
4G FC 4 Gigabit Fibre Channel (a network technology working at
a line rate of 4.25 Gbit/s)
4GSM-#D01-#D16 4-port DWDM group splitter module - blue band (C band)
4GSM-#D17-#D32 4-port DWDM group splitter module - red band (C band)
4GSM-#Dxx-#Dyy 4-port DWDM group splitter module - C or L band
(collective name)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
4ROADM-C96/0/OPM Reconfigurable Optical Add Drop Multiplexer for up to
degree 4 interconnection nodes; supports 96 C-band
channels and optical power monitoring; WSS based, with
integrated 1x4 power splitter, directed/directionless,
gridless, colored/colorless, for dual client applications from
1 to 3 degrees. additional dual pass through
4TCA-PCN-4GU+4G access type 4-port TDM channel module with four client
and two network pluggable interfaces; maximum client
data rate of 4 Gbit/s; multirate clock user selectable;
aggregated data rate on the network port of 4 Gbit/s
4TCA-PCN-4GUS+4G Access type 4-port TDM channel module with four client
and two network pluggable interfaces; supports 1GbE,
STM-1/OC-3 and STM-4/OC-12 on the client ports;
aggregated data rate on the network port of 4.25 Gbit/s
4TCC-PCN-2G1U+2G5 core Type 4-Port multirate TDM channel module with four
client and two network pluggable interfaces; max. client
data rate of 2.125 Gbit/s; aggregated data rate on the
network port of 2.5 Gbit/s
4TCC-PCTN-2G7+10G-LN#DC core type 4-port TDM channel module with four pluggable
interfaces on the client side and one long reach link,
tunable DWDM network interface on the network side;
maximum client data rate of 2.7 Gbit/s; aggregated data
rate on the network port of 10 Gbit/s

32 Module and System Specification


4TCC-PCTN-2G7+10G-V#DC core type 4-port TDM channel module with four pluggable
interfaces on the client side and one integrated, very-long
reach link distance, tunable DWDM interface.on the
network side; support of C-band channels only; maximum
client data rate of 2.7 Gbit/s; aggregated data rate on the
network port of 10 Gbit/s
4TCC-PCTN-2G7+10G-V#DL core type 4-port TDM channel module with four pluggable
interfaces on the client side and one integrated, very-long
reach link distance, tunable DWDM interface.on the
network side; support of L-band channels only; maximum
client data rate of 2.7 Gbit/s; aggregated data rate on the
network port of 10 Gbit/s
4WCE-PCN-16GFC Enterprise type, multirate WDM quad transponder module
with four pluggable client interfaces and four pluggable
network interfaces, supports 16 G FC, 8 G FC and 10 GbE
LAN PHY on the client and network ports
5G IB 5 gigabit Infiniband
5GSM-#19590-#19200 5-port DWDM group splitter module - C band
5GSM/P-#19590-#19200-DM passive 5-port DWDM channel group splitter and combiner
module with monitoring port for dual power level
monitoring; separates/combines 5 DWDM C-band channel
groups
5PSM 5-port passive C-band optical power splitter and combiner
module, needed for the deployment of an CCM-C40/8 or
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

CCM-C80/8
5TCE-PCN-10GU+10G enterprise type 5-port TDM channel module with five
SFP/SFP+ interfaces on the client side and a single SFP+
interface on the network side; maximum client data rate of
10.5 Gbit/s; maximum aggregated data rate on the network
port of 11.3 Gbit/s
5TCE-PCN-10GU+AES10G enterprise type 5-port TDM channel module with five
SFP/SFP+ interfaces on the client side and a single SFP+
interface on the network side supporting data encryption;
maximum client data rate of 10.5 Gbit/s; maximum
aggregated data rate on the network port of 11.3 Gbit/s
5TCE-PCTN-10GU+10G enterprise type 5-port TDM channel module with five
pluggable client interfaces and one integrated 10 Gigabit
DWDM network interface that is fully tunable in the C or L
band; module is available in three variants (collective
name)
5TCE-PCTN-10GU+10G-LN#DC enterprise type 5-port TDM channel module with five
pluggable interfaces on the client side and one integrated
10 Gigabit long reach noise optimized tunable
50 GHz-spaced DWDM interface on the network side;
support of C-band channels only; maximum client data rate
of 10.5 Gbit/s; maximum aggregated data rate on the
network port of 11.3 Gbit/s

Module and System Specification 33


5TCE-PCTN-10GU+10G-V#DC enterprise type 5-port TDM channel module with five
pluggable interfaces on the client side and one integrated
10 Gigabit very long reach tunable 50 GHz-spaced DWDM
interface on the network side; support of C-band channels
only; maximum client data rate of 10.5 Gbit/s; maximum
aggregated data rate on the network port of 11.3 Gbit/s
5TCE-PCTN-10GU+10G-V#DL enterprise type 5-port TDM channel module with five
pluggable interfaces on the client side and one integrated
10 Gigabit very long reach tunable 100 GHz-spaced
DWDM interface on the network side; support of L-band
channels only; maximum client data rate of 10.5 Gbit/s;
maximum aggregated data rate on the network port of 11.3
Gbit/s
5TCE-PCTN-10GU+AES10G enterprise type 5-port TDM channel module with five
pluggable client interfaces and one integrated 10 Gigabit
DWDM network interface that is fully tunable in the C or L
band and supports data encryption; module is available in
three variants:
5TCE-PCTN-10GU+AES10G-V#DC,
5TCE-PCTN-10GU+AES10G-V#DL,
5TCE-PCTN-10GU+AES10G-LN#DC
5TCE-PCTN-10GU+AES10G-LN#DC enterprise type 5-port TDM channel module with five
pluggable interfaces on the client side and one integrated
10 Gigabit long reach, noise optimized, C-band tunable

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
50 GHz-spaced DWDM interface on the network side
supporting data encryption; maximum client data rate of
10.5 Gbit/s; maximum aggregated data rate on the network
port of 11.3 Gbit/s
5TCE-PCTN-10GU+AES10G-V#DC enterprise type 5-port TDM channel module with five
pluggable interfaces on the client side and one integrated
10 Gigabit very long reach C-band tunable 50 GHz-spaced
DWDM interface on the network side supporting data
encryption; maximum client data rate of 10.5 Gbit/s;
maximum aggregated data rate on the network port of 11.3
Gbit/s
5TCE-PCTN-10GU+AES10G-V#DL enterprise type 5-port TDM channel module with five
pluggable interfaces on the client side and one integrated
10 Gigabit very long reach, L-band tunable
100 GHz-spaced DWDM interface on the network side
supporting data encryption; maximum client data rate of
10.5 Gbit/s; maximum aggregated data rate on the network
port of 11.3 Gbit/s
5TCE-PCTN-8GU+10GS Enterprise type 5-port TDM channel module with five
pluggable client interfaces and one integrated 10 Gigabit
DWDM network interface that is fully tunable in the C band
and supports SDH/Sonet; module is available in two
variants:
5TCE-PCTN-8GU+10GS-LN#DC,
5TCE-PCTN-8GU+10GS-V#DC

34 Module and System Specification


5TCE-PCTN-8GU+10GS-LN#DC Enterprise type 5-port TDM channel module with five
pluggable interfaces on the client side and one integrated
10 Gigabit long reach, noise optimized, tunable
50 GHz-spaced C-band DWDM interface on the network
side; support of SDH/Sonet on the network interface;
maximum client data rate of 8.5 Gbit/s; aggregated data
rate on the network port of 9.95328 Gbit/s
5TCE-PCTN-8GU+10GS-V#DC Enterprise type 5-port TDM channel module with five
pluggable interfaces on the client side and one integrated
10 Gigabit very long reach, tunable 50 GHz-spaced
C-band DWDM interface on the network side; maximum
client data rate of 8.5 Gbit/s; aggregated data rate on the
network port of 9.95328 Gbit/s
5TCE-PCTN-8GU+AES10GS Enterprise type 5-port TDM channel module with five
pluggable client interfaces and one integrated DWDM
network interface that is fully tunable in the C band and
supports SDH/Sonet data encryption; module is available
in two variants:
5TCE-PCTN-8GU+AES10GS-LN#DC
5TCE-PCTN-8GU+AES10GS-V#DC
5TCE-PCTN-8GU+AES10GS-LN#DC Enterprise type 5-port TDM channel module with five
pluggable interfaces on the client side and one integrated
long reach, noise optimized, C-band tunable
50 GHz-spaced DWDM interface on the network side
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

supporting SDH/Sonet data encryption; maximum client


data rate of 8.5 Gbit/s; aggregated data rate on the
network port of 9.95328 Gbit/s
5TCE-PCTN-8GU+AES10GS-V#DC Enterprise type 5-port TDM channel module with five
pluggable interfaces on the client side and one integrated
10 Gigabit very long reach, tunable 50 GHz-spaced
C-band DWDM interface on the network side supporting
SDH/Sonet data encryption; maximum client data rate of
8.5 Gbit/s; aggregated data rate on the network port of
9.95328 Gbit/s
7HU Shelf 7 HU-high equipment shelf
8CSM-#19xxx-#19yyy 8-port DWDM channel splitter and combiner module for the
C band, separates/combines 8 DWDM C-band channels 
(collective name)
8CSM/P-#19xxx-#19yyy passive 8-port DWDM channel splitter and combiner
module; separates/combines 8 DWDM C-band channels
(collective name)
8CSM/P-#C1270-#C1450 passive 8-port CWDM channel splitter module with
monitoring port; separates/combines 8 CWDM channels
8CSM/P-#C1470-#C1610-DM passive 8-port CWDM channel splitter module with
monitoring port for dual power level monitoring;
separates/combines 8 CWDM channels and one gray
channel

Module and System Specification 35


8CSM/P+#C1470-#C1610-DM passive 8-port CWDM channel splitter and combiner
module with upgrade port and monitoring port for dual
power level monitoring; separates/combines 8 CWDM
channels and one gray channel
8CSM+#C1470-#C1610 8-port CWDM channel splitter module with upgrade port (It
separates/combines 8 CWDM channels and one gray
channel.)
8GSM-#D01-#D32 8-port DWDM group splitter module - C band
8PSM 8-port passive C-band optical power splitter and combiner
module, needed for deployment of the CCM-C96/9
8ROADM-C40/0/OPM Reconfigurable Optical Add Drop Multiplexer for up to
degree 8 interconnection nodes; supports 40 C-band
channels and optical power monitoring
8ROADM-C80/0/OPM Reconfigurable Optical Add Drop Multiplexer for up to
degree 8 interconnection nodes; supports 80 C-band
channels and optical power monitoring
96CSM/4HU-#19600-#19125 96-port MUX/DMX channel splitter and combiner shelf with
4HU design height supporting the C-band channels from
#19600 through #19125 spaced at 50 GHz
9HU Shelf 9 HU-high equipment shelf for high power consuming
CWDM or DWDM installations
9ROADM-C96/0/OPM Reconfigurable optical add-drop multiplexer for up to 10
degrees (interconnection to other nodes) supporting
ninety-six 50 GHz spaced C-band channels with channel

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
frequencies from 191.25 THz through 196.00 THz; each
client port used for add-drop services reduces the potential
number of degrees supported.
 ohm (SI unit of electrical impedance or, in the direct current
case, electrical resistance)
µm micrometer
µs microsecond

A
A ampere
AC alternating current
acc. according to
ADM add-drop multiplexer
ADVA ADVA Optical Networking
AES advanced encryption standard
AID access identifier
AINS automatic in-service
AIS alarm indication signal
ALS automatic laser shutdown
amp amplifier

36 Module and System Specification


AMP-S20H-C15 dual optical amplifier module with high gain EDFA and BWD Raman;
supports 96 C-band channels, 15 to 30 dB span loss, OSC filter and level
control, Fiber Map Detection
AMP-S20L-C15 dual optical amplifier module with low gain EDFA and BWD Raman; sup-
ports 96 C-band channels, 15 to 30 dB span loss, OSC filter and level
control, Fiber Map Detection
ANSI American National Standards Institute
APS automatic protection switching
ARC alarm reporting control
ASCII American Standard Code for Information Interchange
ASE amplified spontaneous emission
ASIC application specific integrated circuit
ATC adaptive threshold control
ATM asynchronous transfer mode
ATM 155 asynchronous transfer mode 155 Mbit/s
ATM 622 asynchronous transfer mode 622 Mbit/s
AWG american wire gauge (standard method of denoting wire diameter,
especially for electrically conducting wires)

B
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

B1 bit interleaved parity covers the complete frame including overhead


B2 bit interleaved parity covers payload area + multiplexer section overhead
BBE background block errors
BDI backward defect indicator
BER bit error ratio
BERCE bit error ratio based on corrected errors
BMP Bit-synchronous Mapping Procedure
BSM band splitter module (collective name)

C
CBS Committed Burst Size (bandwidth profile parameter according to MEF)
CCM-C40/8 8-port colorless channel module supporting 40 C-band channels, WSS
based
CCM-C80/8 8-port colorless channel module supporting 80 C-band channels, WSS
based
CCM-C96/9 9-port colorless channel module supporting 96 C-band channels, WSS
based
CDR clock and data recovery
CE corrected errors
CEM/9HU Common Equipment Module for 9HU Shelf, with PSCU and UTM
functionality, one CEM/9HU required per 9HU Shelf
CFP centum form factor pluggable

Module and System Specification 37


CH channel
CIR committed information rate
CL Coupling Link
CLEI common language equipment identifier (registered trademark of
Telcordia)
CLI command line interface
CLNP connectionless network protocol
CLSM C/L band splitter module (collective name)
CPE customer premises equipment
C-R receiver (connector) for the client port
CSF client signal fail
CSM channel splitter module (collective name)
C-T transmitter (connector) for the client port
C-tag customer VLAN tag (inner tag on network port)
CTS clear to send (serial connection)
CV coding violations
CVID customer edge VLAN Identification
CVLAN customer VLAN
CWDM coarse wavelength division multiplexing

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
D- data (line balanced)
D+ data (line balanced)
dB decibel
dBm decibel milliwatt
DC direct current
DCCm data communications channel for multiplexer section
DCCr data communications channel for regenerator section
DCD data carrier detect (serial connection)
DCF dispersion compensating fiber
DCF1HU-P dispersion compensation shelf with an integrated DCF spool,
rack-mountable, 1 HU high
DCF1HU-P/010/MCOR dispersion compensation shelf with an integrated DCF spool that
compensates for 10 km of G. 655 MetroCore fiber
DCF1HU-P/020/MCOR dispersion compensation shelf with an integrated DCF spool that
compensates for 20 km of G. 655 MetroCore fiber
DCF1HU-P/020/SSMF dispersion compensation shelf with an integrated DCF spool that
compensates for 20 km of G. 652 standard single-mode fiber
DCF1HU-P/030/MCOR dispersion compensation shelf with an integrated DCF spool that
compensates for 30 km of G. 655 MetroCore fiber
DCF1HU-P/040/MCOR dispersion compensation shelf with an integrated DCF spool that
compensates for 40 km of G. 655 MetroCore fiber
DCF1HU-P/040/SSMF dispersion compensation shelf with an integrated DCF spool that
compensates for 40 km of G. 652 standard single-mode fiber

38 Module and System Specification


DCF1HU-P/050/MCOR dispersion compensation shelf with an integrated DCF spool that
compensates for 50 km of G. 655 MetroCore fiber
DCF1HU-P/060/MCOR dispersion compensation shelf with an integrated DCF spool that
compensates for 60 km of G. 655 MetroCore fiber
DCF1HU-P/060/SSMF dispersion compensation shelf with an integrated DCF spool that
compensates for 60 km of G. 652 standard single-mode fiber
DCF1HU-P/100/LEAF dispersion compensation shelf with an integrated DCF spool that
compensates for 100 km of G. 655 standard large effective area fiber
DCF1HU-P/100/SSMF dispersion compensation shelf with an integrated DCF spool that
compensates for 100 km of G. 652 standard single-mode fiber
DCF1HU-P/100/TWRS dispersion compensation shelf with an integrated DCF spool that
compensates for 100 km of G. 655 standard true wave reduced slope
fiber
DCF1HU-P/120/LEAF dispersion compensation shelf with an integrated DCF spool that
compensates for 120 km of G. 655 standard large effective area fiber
DCF1HU-P/120/SSMF dispersion compensation shelf with an integrated DCF spool that
compensates for 120 km of G. 652 standard single-mode fiber
DCF1HU-P/120/TWRS dispersion compensation shelf with an integrated DCF spool that
compensates for 120 km of G. 655 standard true wave reduced slope
fiber
DCF1HU-P/140/LEAF dispersion compensation shelf with an integrated DCF spool that
compensates for 140 km of G. 655 standard large effective area fiber
DCF1HU-P/140/SSMF dispersion compensation shelf with an integrated DCF spool that
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

compensates for 140 km of G. 652 standard single-mode fiber


DCF1HU-P/140/TWRS dispersion compensation shelf with an integrated DCF spool that
compensates for 140 km of G. 655 standard true wave reduced slope
fiber
DCF1HU-P/160/LEAF dispersion compensation shelf with an integrated DCF spool that
compensates for 160 km of G. 655 standard large effective area fiber
DCF1HU-P/160/SSMF dispersion compensation shelf with an integrated DCF spool that
compensates for 160 km of G. 652 standard single-mode fiber
DCF1HU-P/160/TWRS dispersion compensation shelf with an integrated DCF spool that
compensates for 160 km of G. 655 standard true wave reduced slope
fiber
DCF1HU-P/180/LEAF dispersion compensation shelf with an integrated DCF spool that
compensates for 180 km of G. 655 standard large effective area fiber
DCF1HU-P/180/SSMF dispersion compensation shelf with an integrated DCF spool that
compensates for 180 km of G. 652 standard single-mode fiber
DCF1HU-P/180/TWRS dispersion compensation shelf with an integrated DCF spool that
compensates for 180 km of G. 655 standard true wave reduced slope
fiber
DCF-M/010/SSMF dispersion compensation module that compensates for 10 km of G. 652
standard single-mode fiber
DCF-M/020/SSMF dispersion compensation module that compensates for 20 km of G. 652
standard single-mode fiber
DCF-M/030/SSMF dispersion compensation module that compensates for 30 km of G. 652
standard single-mode fiber

Module and System Specification 39


DCF-M/040/SSMF dispersion compensation module that compensates for 40 km of G. 652
standard single-mode fiber
DCF-M/050/SSMF dispersion compensation module that compensates for 50 km of G. 652
standard single-mode fiber
DCF-M/060/SSMF dispersion compensation module that compensates for 60 km of G. 652
standard single-mode fiber
DCF-M/070/SSMF dispersion compensation module that compensates for 70 km of G. 652
standard single-mode fiber
DCF-M/080/SSMF dispersion compensation module that compensates for 80 km of G. 652
standard single-mode fiber
DCF-M/090/SSMF dispersion compensation module that compensates for 90 km of G. 652
standard single-mode fiber
DCF-M/100/SSMF dispersion compensation module that compensates for 100 km of G. 652
standard single-mode fiber
DCF-M/xxx/yyyy dispersion compensation module (collective name)
DCG-M/060/SSMF Fiber-Bragg-Grating dispersion compensation module that compensates
in a 100 GHz channel grid for 60 km of G. 652 standard single-mode fiber
DCG-M/080/SSMF Fiber-Bragg-Grating dispersion compensation module that compensates
in a 100 GHz channel grid for 80 km of G. 652 standard single-mode fiber
DCG-M/100/SSMF Fiber-Bragg-Grating dispersion compensation module that compensates
in a 100 GHz channel grid for 100 km of G. 652 standard single-mode
fiber
DCG-M/xxx/SSMF Fiber-Bragg-Grating dispersion compensation module (collective name)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The part /xxx of the module name refers to the compensation capability
of C-band channels in a 100 GHz channel grid.
DCG-M/160/TWRS Fiber-Bragg-Grating dispersion compensation module that compensates
in a 100 GHz channel grid for 160 km of true wave-reduced-slope fiber
DCG-M/240/TWRS Fiber-Bragg-Grating dispersion compensation module that compensates
in a 100 GHz channel grid for 240 km of true wave-reduced-slope fiber
DCG-M/320/TWRS Fiber-Bragg-Grating dispersion compensation module that compensates
in a 100 GHz channel grid for 320 km of true wave-reduced-slope fiber
DCG-M/xxx/TWRS Fiber-Bragg-Grating dispersion compensation module for compensating
the chromatic dispersion of true wave-reduced-slope fiber (collective
name)
The part /xxx of the module name refers to the compensation capability.
DCG50-M/060/SSMF Fiber-Bragg-Grating dispersion compensation module that compensates
in a 50 GHz channel grid for 60 km of G. 652 standard single-mode fiber
DCG50-M/080/SSMF Fiber-Bragg-Grating dispersion compensation module that compensates
in a 50 GHz channel grid for 80 km of G. 652 standard single-mode fiber
DCG50-M/100/SSMF Fiber-Bragg-Grating dispersion compensation module that compensates
in a 50 GHz channel grid for 100 km of G. 652 standard single-mode fiber
DCG50-M/xxx/SSMF Fiber-Bragg-Grating dispersion compensation module (collective name)
The part /xxx of the module name refers to the compensation capability
of C-band channels in a 50 GHz channel grid.
DCG50-M/160/TWRS Fiber-Bragg-Grating dispersion compensation module that compensates
in a 50 GHz channel grid for 160 km of true wave-reduced-slope fiber
DCG50-M/240/TWRS Fiber-Bragg-Grating dispersion compensation module that compensates
in a 50 GHz channel grid for 240 km of true wave-reduced-slope fiber

40 Module and System Specification


DCG50-M/320/TWRS Fiber-Bragg-Grating dispersion compensation module that compensates
in a 50 GHz channel grid for 320 km of true wave-reduced-slope fiber
DCG50-M/xxx/TWRS Fiber-Bragg-Grating dispersion compensation module for compensating
the chromatic dispersion of true wave-reduced-slope fiber (collective
name)
The part /xxx of the module name refers to the compensation capability
of C-band channels in a 50 GHz channel grid.
DCM dispersion compensation module (collective name)
DCN data communication network
DE disparity error
DEMUX (1) demultiplexer
(2) demultiplexing
DFB laser distributed feed-back laser
DP-QPSK Dual Polarization Quadrature Phase Shift Keying
DS defect seconds
DSA digital signature algorithm key encryption scheme
DSC digital supervisory channel
DSL digital subscriber line
DSR data set ready (serial connection)
DTR data terminal ready (serial connection)
DW digital wrapper
DWDM dense wavelength division multiplexing
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

E
E extension
e.g. for example (exempli gratia)
e/o electrical to optical conversion
ECC embedded control channel
EOC embedded operations channel
EDFA Erbium-Doped Fiber Amplifier (collective name)
EDFA-C-D17-GC optical amplifier, double stage 17 dBm maximum output power, gain
controlled (C band)
EDFA-C-D20-VGC-DM full-band, variable gain and transient-controlled, double-stage, dual
monitoring C-band EDFA module, 21.3 dBm maximum output power
EDFA-C-D20-VLGC-DM full-band, variable low gain and transient-controlled, double-stage, dual
monitoring C-band EDFA module, 20.5 dBm maximum output power
EDFA-C-S20-GCB-DM full-band, fixed gain and transient-controlled booster, single-stage, dual
monitoring C-band EDFA module, 18.5 dBm maximum output power
EDFA-C-S26-VGC-DM full band, variable gain and transient-controlled single-stage, C-band
EDFA module, maximum output power of 27 dBm, OSC center
wavelength of 1510 nm
EDFA-C-S26-VGCB-DM full band, variable gain and transient-controlled booster, single-stage,
dual monitoring, C-band EDFA module, maximum output power of
26 dBm, OSC center wavelength of 1528.77 nm

Module and System Specification 41


EDFA-L-D17-GC optical amplifier, double stage 17 dBm maximum output power, gain and
transient controlled (L band)
EDFA-S20H high gain, gain-controlled single-stage EDFA with up to 20 dBm output
power; includes OSFM add-drop filter (1528.77nm), dual monitor ports,
VOA at the output, and Fiber Map Detector; operates over spans
supporting 96-C band channels
EDFA-S20L low gain, gain-controlled single-stage EDFA with up to 20 dBm output
power; includes OSFM add-drop filter (1528.77nm), dual monitor ports,
VOA at the output, and Fiber Map Detector; operates over spans
supporting 96-C band channels
EFEC Enhanced forward error correction code
EFEC-1 Super FEC code according to ITU-T G. 975.1 I.7
EFEC-2 Super FEC code according to ITU-T G. 975.1 I.4
EFEC-3 Super FEC code according to ITU-T G. 975.1 I.6
EFEC-4 Proprietary Turbo-Product Code based soft-decision FEC with internal
Hamming code
EFEC-5 Proprietary Super FEC with configurable coding gain
EFEC-6 Proprietary Turbo-Product Code based soft-decision FEC
E-LAN Ethernet transparent LAN service
E-Line Ethernet Private Line service
EMC electromagnetic compatibility
EMI electromagnetic interference
EN european standard

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
EOC embedded operations channel
EPT error propagation code
EPL Ethernet Private Line
eROADM (1) electrically-reconfigurable optical add/drop multiplexer 
(2) enhanced reconfigurable optical add/drop multiplexer
EQPT equipment
ES errored seconds
E-TREE Ethernet tree service
ESCON enterprise system connection
ESD electrostatic discharge
ETSI European Telecommunications Standards Institute
ETH-CC Ethernet Continuity Check
EVC Ethernet Virtual Connection
Even channels channels with frequencies of 196.00 THz to 192.00 THz (#D01 to #D32)
with a spacing of 100 GHz
EVPL Ethernet Virtual Private Line

F
F2488 2.488 gigabit
F9953 9.953 gigabit
FAN/9HU plug-in fan unit for the 9HU Shelf

42 Module and System Specification


FAN/Plug-In plug-in fan unit for the 7HU Shelf
FC fibre channel (protocol)
FCU Fan Control Unit
FDDI fiber distributed data interface -> Glossary
FE fast ethernet
FEC forward error correction
FEND far end
FICON FIbre CONnection. This is the IBM implementation of the ANSI Fibre
Channel Standard. FICON is identical to the Fibre Channel Protocol up to
layer FC-3. All FSP 3000R7 channel modules supporting Fibre Channel
can transport FICON as well unless otherwise noted.
FICON FCV FICON FCV or Bridge is an IBM proprietary protocol operating at 
1.0625 Gbit/s. In general FCV cannot be transported by FSP 3000R7
channel modules even if they support Fibre Channel unless otherwise
noted.
FPGA field programmable gate array
FSP Fiber Service Platform
FSP 3000R7 Fiber Service Platform 3000 Release 7
FSP EM FSP Element Manager -> Glossary
FSP NM FSP Network Manager -> Glossary
FSP NP FSP Network Planner -> Glossary
FT-1 FT-1 Vertical Flame Test per CSA C22.2
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

FTP file transfer protocol


FWP firmware package

G
g gram (SI base unit of mass)
G gigabit
GbE gigabit ethernet
Gbit/s gigabits per second
GCC0 generic communication channel 0 in the OTU overhead
GCC1 generic communication channel 1 in the OTU overhead
GCC2 generic communication channel 2 in the OTU overhead
GFEC Reed-Solomon FEC code according to ITU-T G.975
GFP generic framing procedure according to ITU-T G.7041
GFP-F generic framing procedure, frame-mapped
GFP-T generic framing procedure, transparent-mapped
GHz gigahertz
G-Link Gigabit link
GMP Generic Mapping Procedure according to ITU-T G.709 (for mapping a
client signal with any bit rate less than the payload capacity to the ODU
GND signal ground (serial connection)
GSM group splitter module

Module and System Specification 43


H
h hour
HDLC high-level data link control -> Glossary
HP horizontal pitch (1 HP = 5.08 mm = 1/5 in)
HST hot standby
HU height unit (1 HU = 44.45 mm = 1.75 in)
HW hardware
Hz Hertz

I
IB InfiniBand (protocol)
i.e. that is (id est)
I/O input/output
IEC International Electronical Commission
ID identification (identification number)
ILM50-#DC passive optical module that provides signal interleaving and
de-interleaving in 50-GHz channel spacing DWDM systems. It is
optimized to cover the C-band channels only.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
I-NNI Internal-Network to Network Interface
in inch(es)
Intel IXF19303 Device bandwidth aggregation and channelizer devices with virtual
concatenation
IP [1] internet protocol
[2] ingress protection, a term that refers to the classification of the
protection level that electrical appliances provide
IPv4 internet protocol version 4
ITU International Telecommunication Union
ITU-T ITU Telecommunications Standardization Sector

J
J/SM/4CS-#C1270-#C1 5-port unidirectional CWDM channel splitter/combiner for channels
330/LC/0400 #C1270 - #C1330. It is designed for connecting a 40G transceiver CFP
(LR4) to four 10G transceiver SFP+ interfaces, enabling transmission of
40G traffic over 10G channels.

K
kg kilogram (SI base unit of mass)
km kilometer (SI unit of length in the metric system)

44 Module and System Specification


L
L2 layer two
L2CP Layer 2 Control Protocol
LAD layer adjacency discovery
LAG Link Aggregation Group
LAN local area network
LASER Laser failure alarm
LBCL laser bias current level
LBCLANR laser bias current level abnormal
LC connector type
LCD liquid crystal display
LCK locked defect
LDCC line data communications channel
LED light emitting diode
LKDO-CSF Locked out - client signal fail (autonomous shutdown)
LKDO-OFF Locked out - laser off (autonomous shutdown)
LLP loss of link pulse
LOC loss of clock
LOF loss of frame
LOL loss of logical lane
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

LOM loss of multiframe


LOS loss of signal
LTC loss of tandem connection

M
m meter
MAC media access control
MAN metropolitan area network
max. maximum
Mbit/s megabits per second
MDF Medium Dispersion fiber
MEA mismatch equipment alarm
MEF Metro Ethernet Forum (is a nonprofit international industry consortium,
dedicated to worldwide adoption of Carrier Ethernet networks and
services)
MEP Maintenance Entity Group End Point
mi mile(s)
MIB management information base -> Glossary
min. minimum
mm millimeter
MOD module
ms millisecond

Module and System Specification 45


MSA Multi-Sourcing Agreement standard
MSIM multiplex structure identifier mismatch
MSP multiplexer section protection
MUX (1) multiplexer
(2) multiplexing

N
NAT network address translation
N-C bidirectional regeneration network-to-client interface
NCU network element control unit
NCU-II network element control unit, second generation, with high performance
processor
NCU-II-P network element control unit, second generation, supporting High
Availability set-ups
NE network element
NEBS Network Equipment Building Standards
NECG net electrical coding gain
NEND near end
NE-R receiver (connector) for the network port east
NE-T transmitter (connector) for the network port east

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
nm nanometer
NMS network management system
N-N bidirectional regeneration network-to-network interface
NNI Network to Network Interface (is an interface which specifies signaling
and management functions between two networks)
NPCUP network protected client unprotected protection
N-R receiver (connector) for the network port
NSAP network service access point
N-T transmitter (connector) for the network port
NTP network time protocol
NW-R receiver (connector) for the network port west
NW-T transmitter (connector) for the network port west

O
o/e optical to electrical conversion
OA optical amplifier
OAM remote operations, administration and maintenance
OC-1 optical carrier level 1 (with 51.84 Mbit/s)
OC-12 optical carrier level 12 (with 622 Mbit/s)
OC-192 optical carrier level 192 (with 9.953 Gbit/s)
OC-3 optical carrier level 3 (with 155 Mbit/s)
OC-48 optical carrier level 48 (with 2.5 Gbit/s)

46 Module and System Specification


OCI open connection indication
Odd channels channels with frequencies of 195.95 THz to 192.05 THz with a spacing of
50 GHz
ODTU4.ts optical channel data tributary unit 4 with an specific amount of tributary
slots (ts)
ODU optical channel data unit
ODU0 optical channel data unit (1.22 Gbit/s)
ODU1 optical channel data unit (2.666 Gbit/s)
ODU2 optical channel data unit (10.7092 Gbit/s)
ODUflex concept of a flexible rate ODU structure allowing an alternative mapping
method (GMP) without complexity of Virtual Concatenation defined by
ITU-T G.709.
OOFS out of frame seconds
OPM optical power monitor
OPR optical power receive
OPSM Optical Physical Section Multilane (a layer in the OTN standard)
OPT optical power transmit
OPU4 optical channel payload unit 4 (frame structure for transport of 100GbE
according to ITU-T G.709)
OSC optical supervisory channel
OSCM OSC module (collective name)
OSCM-PN Optical Supervisory Channel Module with optical line monitoring and dual
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

pluggable optical network interfaces


OSF optical supervisory channel filter
OSFM optical supervisory channel filter module (collective name)
OSFM+#1510 optical supervisory channel filter module with upgrade port, OSC
transmitter wavelength at 1510 nm
OSFM+#1490-SFB optical supervisory channel filter module - single-fiber working, location B
OSFM+#1510-SFA optical supervisory channel filter module - single-fiber working, location A
OSNR optical signal-to-noise ratio
OSP outside plant
OTDR optical time domain reflectometer that combines a test head controller
(OTDR/THC/2HU/AC) unit and optical test head (OTDR/8-OTH/1HU/AC)
unit
OTDR/8-OTH/1HU/AC Optical Time Domain Reflectometer, 8-port Optical Test Head
OTDR/THC/2HU/AC Optical Time Domain Reflectometer, Test Head Controller
OTH optical transport hierarchy (ITU-T G.709)
OTN optical transport network (ITU-T G.709)
OTU1 optical channel transport unit 1 (2.666 Gbit/s)
OTU1e Overclocked OTN data rate for transportation of 10Gbe-LAN
transparently over OTN networks. The fixed stuff bytes of the 10GbELAN
signal are removed. The data rate is 11.0491 Gbit/s +/- 100 ppm.
OTU2 optical channel transport unit 2 (10.7092 Gbit/s)

Module and System Specification 47


OTU2e Overclocked OTN data rate for transportation of 10Gbe-LAN
transparently over OTN networks. The 10GbE signal with fixed stuff
bytes are mapped into an OPU signal. As the stuff bytes are not removed
the data rate of OTU2e is 11.0957 Gbit/s +/- 100 ppm, which is
somewhat lower than the rate of OTU1e.
OTU4 optical channel transport unit 4 (111.809 Gbit/s)

P
PC personal computer
PCB printed circuit board
PCS physical coding sublayer
PDU (1) protocol data unit
(2) power distribution unit
PG (1) protection group mode
(2) protection group (a pair of client ports on the same or different
channel modules)
PG-P protection group mode - protection traffic
PG-W protection group mode - working traffic
Pin max maximum permissible optical input power at network port receiver
PLC planar lightwave circuit

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
PLM payload mismatch
PM protection module (collective name)
performance monitoring
PMD polarization mode dispersion
ppm (oscillator) parts-per-million
PPP point-to-point protocol
ps pico second
PSCP PuTTY secure copy program
PSCU Passive Shelf Control Unit
PSM-95/5 power splitter module for power monitoring and optical spectrum analysis
PSU power supply unit
PSU/1HU-R-AC AC power supply unit for a 1HU shelf with rear power access
PSU/1HU-R-AC-200 AC power supply unit for a 1HU shelf with rear power access;
It delivers a maximum output power of 200 W
PSU/1HU-R-DC-200 DC-input power supply unit for a 1HU shelf with rear power access; 
It delivers a maximum output power of 200 W
PSU/7HU-AC AC power supply unit for a 7HU Shelf
PSU/7HU-AC-800 AC power supply unit for a 7HU Shelf and 9HU Shelf; 800W output
power are needed for operation in the shelf
PSU/7HU-DC DC power supply unit for a 7HU Shelf
PSU/7HU-R-DC DC power supply unit for a 7HU Shelf rear power access
PSU/7HU-AC-HP High-Power AC Power Supply Unit for a 7HU Shelf and 9HU Shelf with
front power access

48 Module and System Specification


PSU/7HU-DC-HP High-Power DC power supply unit for a 7HU Shelf with front power
access
PSU/7HU-R-DC-HP High-Power DC power supply unit for a 7HU Shelf with front power
access
PSU/9HU-AC AC-input power supply unit for a 9HU Shelf
PSU/9HU-DC DC-input power supply unit for a 9HU Shelf
pwr 1 power feed 1
pwr 2 power feed 2

R
R receive
RADIUS Remote Authentication Dial-In User Service
RAM random access memory
RAMAN-C10 C-band Distributed Fiber Raman Amplifier with constant pump
power, which provides up to 10 dB of Raman gain in a G.652
fiber.
RCVCLK receiver clock failure (loss of clock)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

RDI remote defect indicator (defect indication signal)


RFC request for comments
RI ring indicator (serial connection)
RJ-45 registered jack-45
RLM remote line monitoring
RMA return materials authorization
ROADM Reconfigurable Optical Add/Drop Multiplexer
ROADM-C80/0/OPM Reconfigurable Optical Add/Drop Multiplexer (ROADM) 2
degree, 80 channels in C-Band, WSS based, with integrated
performance monitor
RoHS Restriction of the Use of Certain Hazardous Substances in
electrical and electronical equipment
rpm revolutions per minute
RTS request to send (serial connection)
RS read salomon
RS 232 recommended standard-232
RSA Rivest, Shamir and Adelman key encryption scheme
RSM-OLM remote switch module with optical line monitoring (collective
name)
RSM-OLM#1630 remote switch module with optical line monitoring, the pilot laser
of which operates at a wavelength of 1630 nm
Rx receiver
RxD received data (serial connection)
RxESFail Rx elastic storage failure

Module and System Specification 49


S
s second
SCP secure copy program
SCU shelf control unit
SCU-S Shelf Control Unit for 1HU Shelf
SCU-II Shelf Control Unit, second generation, supporting High
Availability set-ups
SD signal degrade
SD-SDI serial digital interface
HD-SDI high-definition serial digital interface
SDCC section data communications channel
SDH synchronous digital hierarchy
SE synch header error
SEFS severely errored framing seconds
SES severely errored seconds
sec. second
Ser serial
SF single fiber
SFP small form-factor pluggable transceiver
SFTP secure file transfer protocol

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFW single-fiber working
SGEO-RATE supporting entity outage alarm - data rate not supported
SH1HU-F/2DC 1HU Shelf equipped with a DC power supply unit and dual front
access power feeds
SH1HU-HP/2DC 1HU Shelf High Power equipped with a DC-input power supply
unit and dual front access power feeds; It is intended for
applications requiring higher wattage and cooling airflow rates.
SH1HU-HP/E-TEMP/2DC 1HU Shelf High Power equipped with a DC-input power supply
unit and dual front access power feeds; It is intended for
extended low ambient temperature operation and applications
requiring higher wattage and cooling airflow rates.
SH1HU-R 1HU Shelf Rear Power Access
SH1HU-R/PF 1HU Shelf Rear Power Access equipped with a pluggable fan
unit, an replaceable air filter and redundant AC power supply
SH1HU/PASSIVE/FT 1HU Passive Shelf with fiber tray
SH7HU 7HU Shelf
SH7HU-R 7HU Shelf rear power access
SH9HU 9HU Shelf
SNMP simple network management protocol
SONET synchronous optical network
SQM loss of sequence
SSF server signal fail
SSH secure shell protocol
SSMF standard single-mode fiber

50 Module and System Specification


S-tag service tag; it designates the service in the provider network.
(outer network tag on network port)
STM-1 synchronous transfer mode, Level 1 (150 Mbit/s)
STM-16 synchronous transfer mode, Level 3 (2.5 Gbit/s)
STM-4 synchronous transfer mode, Level 2 (622 Mbit/s)
STM-64 synchronous transfer mode, Level 4
STP CAT 6 shielded twisted pair category 6 (copper cable type)
SUB D9 9 pins D-subminiature connector
SVID service provider VLAN Identification
SW software

T
T transmit
TCA access type TDM channel module
threshold crossing alert
TCC core type TDM channel module
TCE enterprise type TDM channel module
TCM tandem correction monitoring
TCP transmission control protocol
TDM time division multiplexing
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Telnet teletype network, a telecommunications protocol


TFTP trivial file transfer protocol
TIF telemetry interface
TIM trace trail identifier mismatch
TWRS true wave reduced slope fiber
Tx transmitter
TxD transmitted data (serial connection)
TxClkFail transmitter clock failure

U
UAS unavailable seconds
UBE uncorrected block errors
ULL Ultra Low Loss fiber
UNEQ unequipped
UNI User Network Interface (is a demarcation point between the
responsibility of the service provider and the responsibility of the
subscriber)
USB universal serial bus
UTC universal time coordinated
UTM Utility Module

Module and System Specification 51


V
V volts
VCAT virtual concatenation
VCC +5 V operating voltage
VCCI Voluntary Control Council for Interference by Information Technology
Equipment
VCG virtual container group
VLAN Virtual Local Area Network
VID VLAN Identification (number)
VOA Variable optical attenuator
VSM versatile switch module, triggered by system software via backplane
VW-1 vertical-wire flame test (UL 1581)

W
W (1) width
(2) watt (SI derived unit of power – a term that refers to power
produced as electricity)
WAN wide area network
WCA WDM channel module access type

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
WCA-PCN-2G5U access type 2.5G WDM channel module with a single client and
dual network pluggable interfaces
WCC core type WDM channel module
WCC-PC1N-2G7U core type 2.7G WDM channel module with a pluggable client and
network port.
Both ports are designed for the support of intra office, standard and
long reach as well for the support of CWDM long and very long
reach and DWDM very long and ultra-long reach
WCC-PCTN-10G-LN#DC core type WDM channel module with a pluggable interface on the
client side and a single tunable integrated long reach DWDM
interface on the network side; maximum client and network data
rate of 11.0957 Gbit/s (#DC stands for one of 81 DWDM channels in
the C and L band at 50 GHz)
WCC-PCTN-10G-V#DC core type 10G WDM channel module with pluggable client interface
and integrated, very long reach link distance, tunable DWDM
network interface; maximum client and network data rate of 11.0957
Gbit/s (#DC stands for one of 81 DWDM channels in the C band at
50 GHz according to ITU-T G.694.1.)
WCC-PCTN-10G-V#DL core type 10G WDM channel module with pluggable client interface
and integrated, very long reach link distance, tunable DWDM
network interface; maximum client and network data rate of 11.0957
Gbit/s (#DL stands for one of 41 DWDM channels in the L band at
100 GHz according to ITU-T G.694.1.)

52 Module and System Specification


WCC-PCTN-100GA five-slot core type channel module with pluggable client interface for
CFP transceiver and a single integrated DWDM interface; network
interface is tunable in 50 GHz channel spacing, maximum client
data rate for 100 GBE and OTU4 protocols and network data rate
for OTU4 protocols
WCC-PCTN-100GB four-slot core type channel module with pluggable client interface
for CFP transceiver and a single integrated DWDM interface;
network interface is tunable in 50 GHz channel spacing, maximum
client data rate for 100 GBE and OTU4 protocols and network data
rate for OTU4 protocols
WCE enterprise type WDM channel module (collective name)
WCE-PCN-100G enterprise type 100G WDM channel module with a single CFP client
interface and a single CFP network interface; client port data rates
of 103.1Gbit/s (100GbE); network data rate of 111.81Gbit/s (OTU4);
three slots wide module
WCE-PCN-100GB enterprise type 100G WDM channel module with a single CFP client
interface and a single CFP network interface; client port data rates
of 103.1Gbit/s (100GbE); network data rate of 111.81Gbit/s (OTU4);
two slots wide module
WDM wavelength division multiplexing
WEEE waste electrical and electronic equipment

X
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

XFP extended form-factor pluggable transceiver


xTCA x-port Access Type TDM Channel Module (x stands for number of
client ports)
xTCC x-port Core Type TDM Channel Module (x stands for number of client
ports)
xTCE x-port Enterprise Type TDM Channel Module (x stands for number of
client ports)

Y
y-cable/MM 3-port multimode fiber-optic cable with an integrated 50/50 coupler on
the common end to facilitate channel card protection.
y-cable/SM 3-port single-mode fiber-optic cable with an integrated 50/50 coupler
on the common end to facilitate channel card protection.

Module and System Specification 53


54
Module and System Specification
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Chapter 1

Introduction
This chapter provides an overview of the wavelengths used for the Fiber Service
Platform (FSP 3000R7) and gives information about the defined operating
network wavelengths, FEC codes, equipment disposal, power consumption
values, conformance of laser products and EMC classification.

Wavelength Plan
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

The wavelength plan consists of tables. These tables provide references


between channel name, frequency and wavelength for FSP 3000R7 and FSP
2000.

While the system allows the use of any of the values listed in the table
below on input, it is recommended that when specifying the value of
DWDM channel attributes, the numeric form (e.g. 19200) be used.
This format provides a consistent specification format for the input
PS

value of all DWDM channels, regardless of channel spacing or


Note channel width. The numeric format is used exclusively by the system
within responses and autonomous output messages, regardless of
the format used for channel value input within any related commands.

DWDM Wavelengths
Table 1 and Table 2 are subsets of the ITU-T 694.1 (DWDM) as used by the
FSP 3000R7 system.
"Even" channels refer to the channels with frequencies of 196.00 THz to 192.00
THz with a spacing of 100 GHz. “Odd” channels refer to the channels with
frequencies of 195.95 THz to 192.05 THz with a spacing of 100 GHz as well.
The channel with the frequency of 196.00 THz is available for fixed banded filter
modules only.

Module and System Specification 55


Table 1 contains the DWDM C-band wavelengths used by the FSP 3000R7.

Table 1: C-Band Wavelengths Used by FSP 3000R7


FSP 3000R7 FSP 3000R7
Frequency Wavelength FSP 2000
Old Channel New Channel
THz nm 64 ch. name
Name Name
196.00 1529.55 #D01 19600 E01
195.95 1529.94 19595
195.90 1530.33 #D02 19590 1
195.85 1530.73 19585
195.80 1531.12 #D03 19580 E02
195.75 1531.51 19575
195.70 1531.90 #D04 19570 2
195.65 1532.29 19565
195.60 1532.68 #DC1 19560 E03
195.55 1533.07 19555
195.50 1533.47 #D05 19550 3
195.45 1533.86 19545
195.40 1534.25 #D06 19540 E04
195.35 1534.64 19535
195.30 1535.04 #D07 19530 4
195.25 1535.43 19525

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
195.20 1535.82 #D08 19520
195.15 1536.22 19515
195.10 1536.61 #DC2 19510
195.05 1537.00 19505
195.00 1537.40 #D09 19500
194.95 1537.79 19495
194.90 1538.19 #D10 19490 5
194.85 1538.58 19485
194.80 1538.98 #D11 19480 E05
194.75 1539.37 19475
194.70 1539.77 #D12 19470 6
194.65 1540.16 19465
194.60 1540.56 #DC3 19460 E06
194.55 1540.95 19455
194.50 1541.35 #D13 19450 7
194.45 1541.75 19445
194.40 1542.14 #D14 19440 E07
194.35 1542.54 19435
194.30 1542.94 #D15 19430 8
194.25 1543.33 19425
194.20 1543.73 #D16 19420 E08
194.15 1544.13 19415
194.10 1544.53 #DC4 19410
194.05 1544.92 19405

56 Module and System Specification


Chapter 1 Introduction

Table 1: C-Band Wavelengths Used by FSP 3000R7 (Continued)


FSP 3000R7 FSP 3000R7
Frequency Wavelength FSP 2000
Old Channel New Channel
THz nm 64 ch. name
Name Name
194.00 1545.32 #DC9 19400
193.95 1545.72 19395
193.90 1546.12 #DC5 19390
193.85 1546.52 19385
193.80 1546.92 #D17 19380 E09
193.75 1547.32 19375
193.70 1547.72 #D18 19370 9
193.65 1548.12 19365
193.60 1548.52 #D19 19360 E10
193.55 1548.92 19355
193.50 1549.32 #D20 19350 10
193.45 1549.72 19345
193.40 1550.12 #DC6 19340 E11
193.35 1550.52 19335
193.30 1550.92 #D21 19330 11
193.25 1551.32 19325
193.20 1551.72 #D22 19320 E12
193.15 1552.12 19315
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

193.10 1552.52 #D23 19310 12


193.05 1552.93 19305
193.00 1553.33 #D24 19300
192.95 1553.73 19295
192.90 1554.13 #DC7 19290
192.85 1554.54 19285
192.80 1554.94 #D25 19280
192.75 1555.34 19275
192.70 1555.75 #D26 19270 13
192.65 1556.15 19265
192.60 1556.56 #D27 19260 E13
192.55 1556.96 19255
192.50 1557.36 #D28 19250 14
192.45 1557.77 19245
192.40 1558.17 #DC8 19240 E14
192.35 1558.58 19235
192.30 1558.98 #D29 19230 15
192.25 1559.39 19225
192.20 1559.79 #D30 19220 E15
192.15 1560.20 19215
192.10 1560.61 #D31 19210 16
192.05 1561.01 19205
192.00 1561.42 #D32 19200 E16

Module and System Specification 57


Table 1: C-Band Wavelengths Used by FSP 3000R7 (Continued)
FSP 3000R7 FSP 3000R7
Frequency Wavelength FSP 2000
Old Channel New Channel
THz nm 64 ch. name
Name Name
191.95 1561.83 19195
191.90 1562.23 19190
191.85 1562.64 19185
191.80 1563.05 19180
191.75 1563.45 19175
191.70 1563.86 19170
191.65 1564.26 19165
191.60 1564.67 19160
191.55 1565.08 19155
191.50 1565.48 19150
191.45 1565.89 19145
191.40 1566.30 19140
191.35 1566.70 19135
191.30 1567.11 19130
191.25 1567.52 19125

Modules / transceivers supporting the 100GHz channel grid in the C Band with
41 channels offer channel frequencies from 196.00 THz to 192.00 THz.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Modules / transceivers supporting the 50GHz channel grid in the C Band with 81
channels offer channel frequencies from 196.00 THz to 192.00 THz.
Modules / transceivers supporting the 50GHz channel grid in the C Band with 96
channels offer channel frequencies from 196.00 THz to 191.25 THz.
Table 2 contains the DWDM L-band wavelengths used by the FSP 3000R7.

Table 2: L-Band Wavelengths Used by FSP 3000R7


FSP 3000R7 FSP 3000R7
Frequency Wavelength FSP 2000
Old Channel New Channel
THz nm 64 ch. name
Name Name
191.00 1569.59 #D33 19100 E17
190.90 1570.42 #D34 19090 17
190.80 1571.24 #D35 19080 E18
190.70 1572.06 #D36 19070 18
190.60 1572.89 #DL1 19060 E19
190.50 1573.71 #D37 19050 19
190.40 1574.54 #D38 19040 E20
190.30 1575.37 #D39 19030 20
190.20 1576.20 #D40 19020
190.10 1577.03 #DL2 19010
190.00 1577.86 #D41 19000
189.90 1578.69 #D42 18990 21
189.80 1579.52 #D43 18980 E21

58 Module and System Specification


Chapter 1 Introduction

Table 2: L-Band Wavelengths Used by FSP 3000R7 (Continued)


FSP 3000R7 FSP 3000R7
Frequency Wavelength FSP 2000
Old Channel New Channel
THz nm 64 ch. name
Name Name
189.70 1580.35 #D44 18970 22
189.60 1581.18 #DL3 18960 E22
189.50 1582.02 #D45 18950 23
189.40 1582.85 #D46 18940 E23
189.30 1583.69 #D47 18930 24
189.20 1584.53 #D48 18920 E24
189.10 1585.37 #DL4 18910
189.00 1586.20 #DL9 18900
188.90 1587.04 #DL5 18890
188.80 1587.88 #D49 18880 E25
188.70 1588.73 #D50 18870 25
188.60 1589.59 #D51 18860 E26
188.50 1590.41 #D52 18850 26
188.40 1591.26 #DL6 18840 E27
188.30 1592.10 #D53 18830 27
188.20 1592.95 #D54 18820 E28
188.10 1593.79 #D55 18810 28
188.00 1594.64 #D56 18800
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

187.90 1595.49 #DL7 18790


187.80 1596.34 #D57 18780
187.70 1597.19 #D58 18770 29
187.60 1598.04 #D59 18760 E29
187.50 1598.89 #D60 18750 30
187.40 1599.75 #DL8 18740 E30
187.30 1600.60 #D61 18730 31
187.20 1601.46 #D62 18720 E31
187.10 1602.31 #D63 18710 32
187.00 1603.17 #D64 18700 E32

CWDM Wavelengths
Table 3 contains the CWDM wavelengths according to ITU-T 694.2 and channel
names used by the FSP 3000R7.

Table 3: CWDM Wavelengths Used by FSP 3000R7


Wavelength nm FSP 3000R7 Channel Name
1271.00 #C1270
1291.00 #C1290
1311.00 #C1310
1331.00 #C1330
1351.00 #C1350
1371.00 #C1370

Module and System Specification 59


Table 3: CWDM Wavelengths Used by FSP 3000R7 (Continued)
Wavelength nm FSP 3000R7 Channel Name
1431.00 #C1430
1451.00 #C1450
1471.00 #C1470
1491.00 #C1490
1511.00 #C1510
1531.00 #C1530
1551.00 #C1550
1571.00 #C1570
1591.00 #C1590
1611.00 #C1610

Defined Operating Network Wavelengths


All CWDM/DWDM filter modules have a defined wavelength range and
transmission bandwidth where their optical characteristics are guarantied. The
network interfaces of the FSP 3000R7 channel modules are compatible with the
FSP 3000R7 filter modules.
Some DWDM channel modules cannot be used together with a 50 GHz grid
filter system. Some other DWDM channel modules offer 50 GHz wavelength
stability, but 50 GHz odd channels are not available. Please refer to the

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
specification of the respective channel module or to Appendix A: DWDM
Modules - Channel Grid Support.
The receiver sensitivity of CWDM and DWDM interfaces is given for the
respective transmitter wavelength range. These receivers, excepting the
modules supporting 40G and 100G, can operate with 1310 nm grey signals as
well. In this case the receiver sensitivity may be reduced by up to 2 dB.
The receivers of client interfaces with 1310 nm transmitter can operate with
CWDM or DWDM data signals as well even if not specified. If the specified
receiver wavelength range does not cover the C band and/or L band the
receiver sensitivity may be reduced by up to 2 dB.
850 nm grey interfaces cannot operate with 1310 nm, CWDM or DWDM signals
and vice versa.

60 Module and System Specification


Chapter 1 Introduction

Interoperability of Channel Modules


If not explicitly otherwise stated, e.g. for regeneration purposes, interoperability
of channel modules in one link is guaranteed only if the channel modules are of
the same type with identical firmware version. For replacing a discontinued
module by its successor it could be desirable to connect two modules of
different type. In this case please ask your local ADVA Optical Networking
representative.
Interoperability of channel modules in daisy chaining is not allowed for test
purposes.

FEC Codes
Depending on the type of channel module the following forward error correction
codes are used by the FSP 3000R7 system:
Table 4: FEC Codes
FEC Code Equipment Type
GFEC, Reed-Solomon (255,239) FEC WCC40GT, 4TCC40GT,
code according to ITU-T G.709 WCC10GT-D, 4TCC10GT,
(Annex A) 2TWCC2G7, WCC2G7,
2WCC10G, WCC100GT-D
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

10TCC10GT, 10TCCS10GT,
5TCE10GT, 5TCE10GTAES,
5TCE10G, 5TCE10GAES,
10TCC10G, 10TCE100G1
EFEC-1, Super FEC Code according 4TCC10GT
to ITU-T G.975.1 I.7
EFEC-2, Super FEC Code according WCC10GT, 10TCC10GT,
to ITU-T G.975.1 I.4 10TCCS10GT, 2WCC10G,
10TCC10G
EFEC-3, Super FEC Code according WCC40GT, 4TCC40GT
to ITU-T G.975.1 I.6
EFEC-4, proprietary Turbo-Product WCC100GT-D 
Code based soft-decision FEC (WCC-PCTN-100GA)
(providing 11.2 dB net coding gain)
EFEC-5, proprietary Super FEC with 10TCE100G2, WCE100G,
configurable coding gain WCE100GB, 10TCE100GAES
EFEC-6, proprietary Turbo-Product WCC100GT-D
Code based soft-decision FEC (WCC-PCTN-100GB)
(providing 11.2 dB net coding gain)
1. GFEC only supported on the 10TCE-PCN-10G+100G-GF
2. EFEC-5 only supported on the 10TCE-PCN-10G+100G

Module and System Specification 61


Right to Use Versions
Use of software provided together with the ADVA equipment is subject to the
Right-to-Use (“RTU”) License. You are obliged to retain a certificate as proof
that you have obtained the right to use certain functionalities provided with the
ADVA equipment. For more detailed information, please refer to the current
FSP 3000R7 Release Notes.

Supported Shelf ID Range and Amount of


Shelves per Node
Table 5 provides information about the supported shelf-ID range and amount of
shelves per node.

Table 5: Shelf ID Range and Shelves supported per Node Controller


Supported shelf ID range 1 … 99 if node contains only SCU-II
1 … 50 if node contains at least one SCU
1 … 20 if node contains at least one
ROADM-C40/40/OPM (module
discontinued)
Maximum amount of shelves 20 if node controlled by NCU or NCU2E
(modules discontinued)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
20 if node contains SCU-II deployed in a
protected ring topology
26 if node controlled by NCU-II or NCU-II-P
(may be limited to 20 by shelf ID range)

Compliance Statements
The FSP 3000R7 product family has to comply with EMC, product safety, laser
safety and product marking standards. An overview of the standards applied to
the FSP 3000R7 product family can be found the in the following subsections.

Laser safety requires permissible configurations of amplifiers. Please


PS

refer to the Planning and Engineering Guide and Safety Guide for
allowed configurations.
Note

International
Table below lists EMC, product and laser safety standards valid for international
users. Further information can be found in the Safety Guide.

Table 6: International Standards


EMC Standards CISPR 22, CISPR 24

62 Module and System Specification


Chapter 1 Introduction

Table 6: International Standards (Continued)


Product Safety Standards IEC 60950-1
Laser Safety Standards IEC 60825-1, IEC 60825–2

European Union
Table below lists EMC, product and laser safety standards valid for european
users. Further information can be found in the Safety Guide.

Table 7: Directives and European Standards


EMC directive 2004/108//EC (EMC),
EN 55022:2010, EN 55022:2010/AC:2011, (class A),
EN 55024:2010,
EN 61000-3-2:2006+A2:2009 (for AC versions only),
EN 61000-3-3:2008 (for AC versions only),
EN 300386 V.1.6.1:2012
Product Safety directive 2006/95//EC (LVD),
EN 60950-1:2005+A1:2010
EN 41003:2008
EN 62479:2011
Laser Safety directive 2006/95//EC (LVD),
EN 60825-1:20011,
EN 60825–2:2012/19/EU
WEEE directive 2008/34//EC (WEEE),
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

EN 50419:2006
RoHS directive 2011/65/EU (ROHS),
EN 50581:2012
1. Certified as a Class 1M laser product with hazard level 1M.

The FSP 3000R7 supplied to the community market for the first time meets the
standards valid in the european union.

USA and Canada


Table below lists EMC, product and laser safety standards valid for american
and canadian users. Further information can be found in the Safety Guide.

Table 8: Regulations and American and Canadian Standards


EMC Telcordia GR 1089:2011,
47 CFR Part 15 Subpart B (FCC):2011, class A,
ICES 003:2012
Product Safety UL 60950-1:2011
CAN/CSA 22.2 No. 60950-1-07 (2012)
Laser Safety 21 CFR 1040.101
1. Except for deviations pursuant to Laser Notice No. 50 
(dated 24 June, 2007).

Module and System Specification 63


Jitter Compliance
All channel modules designed for the transport of one of the following
applications are fulfilling the applicable jitter standards at the client ports if not
otherwise stated in the description in chapter 3 of the respective module. The
applicable standards are:

Table 9: Jitter Compliance


Application Standard
1G FC, 2G FC • ANSI / INCITS /T11 1235D /FC-PI5 Rev8.0 apr/2000
• T11.2/Project 1316-DT/ "Fibre Channel Methodolo-
gies" Rev 10 jun/2004
4G FC, 8G FC, • ANSI / INCITS /T11 2118-D /FC-PI5 Rev 6.10
16G FC jan/2011
• T11.2/Project 1734-DT "Fibre Channel Methodolo-
gies" Rev 3.2 sep/2010
• T11.2/Project 1230-DT "Fibre Channel
Methodologies" Rev 5.0
10G FC • NCITS xxx-200x T11/Project 1413-D/Rev 1.1
STM-1, STM-4, • ITU-T recommendations G. 783, G. 813, G.823, G.
STM-16, 824 G.825,
STM-64, • ITU-T recommedations O.171, O.172

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
STM-256
OC-3, OC-12, • Telcordia GR-253, GR-1377,
OC-48, OC-192,
• ANSI T1.101, T1.105.03
OC-768
OTU1, OTU2, • ITU-T recommendations G.709, G.8251,
OTU3, OTU4
• ITU-T recommendation O.173
1 GbE • IEEE 802.3 Clause 38 formerly (IEEE 802.3z)
10 GbE • IEEE 802.3ae 2002, IEEE 802.3ap 2007
40 GbE, 100 • IEEE P802.3ba/D0.9, 25th Aug 200:
GbE LR4
• Draft P802.3ba/D3.11 16th Mar 2010
100 GbE SR10, • IEEE 802.3 2012, subclauses 86.7.3, 86.8.2, 86.8.4,
LR10 86.8.3.3

Environmental Conditions
The FSP 3000R7 product family fulfills several environmental conditions
(ambient temperatures and relative humidity levels) for storage, transportation
and stationary operation of the equipment. These environmental conditions are
specified in:
• Telcordia GR-63-CORE, Issue 4, April 2012 (Telcordia SR-3580:2012 level
3 (NEBS))
• ETSI EN 300 019-1-1 V2.1.8 (2013-12) Storage Class 1.2

64 Module and System Specification


Chapter 1 Introduction

• ETSI EN 300 019-1-2 V2.1.7 (2013-12) Transportation Class 2.2


• ETSI EN 300 019-1-3 V2.3.7 (2013-12) Stationary use at weatherprotected
locations Class 3.1

For temperature and humidity limits, see the individual module


PS

specifications.
Note

Power-on of the FSP 3000R7 system is allowed in operating


PS

temperature range only.


Note

Temperature too high alarms may occur if the ambient temperature is


PS

close to the operating temperature limit. It does not affect proper


operation.
Note

Short-term refers to a period of not more than 96 consecutive hours


and a total of not more than 15 days in 1 year. (This refers to a total of
PS
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

360 hours in any given year, but no more than 15 occurrences during
Note that 1-year period.)

These minimum and maximum values of temperature and humidity are not met
simultaneously.

All specifications in this document are valid for end of life and over the
PS

whole temperature range if not otherwise stated.


Note

Power Consumption
The Power Consumption values given in this document for all modules are
worst case. They are valid for end of life and over the whole temperature range.
Channel modules may be equipped with DWDM pluggable transceivers on the
network ports and CWDM or DWDM pluggable transceivers on the client ports
(where applicable).
For channel modules and amplifiers typical power consumption values are
stated. These values are given for end of life and room temperature (25°C).
Channel modules may be equipped with DWDM pluggable transceivers on the
network ports and grey pluggable transceivers on the client ports (where
applicable).

Module and System Specification 65


Module Delay
Module delay of a channel module is the maximum amount of time to transmit a
data signal in one direction. This number comprises the delay or latency of a
signal applied from the client receive port (C-Rx) to the network transmit port
(N-Tx) of the near-end module and the delay of the signal applied from the
network receive port (N-Rx) to the client transmit port (C-Tx) of the far-end
module in one span. It does not comprise any fiber delay.
Figure 1 illustrates the module delay of channel modules at the near-end and
far-end.

Figure 1: Module Delay of two Channel Modules in one Span


Near‐End Far‐End
Module delay
Time for passing through the data signal from Cx‐R to Cx‐T
Client port  Network ports Client port 

Cx‐R N‐T N‐R Cx‐T

Attenuator

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Module delay of a pluggable transceiver is the sum of delays which are caused
by the optical-electrical conversion of the receiver and the electrical-optical
conversion of the transmitter.
Figure 2 illustrates the module delay of pluggable transceivers.

Figure 2: Module Delay of a Pluggable Transceiver


Module delay
Optical signal
T Time of delays 
Electrical signal loop required for 
Attenuator electrical‐optical/
R optical‐electrical 
conversion. 

66 Module and System Specification


Chapter 1 Introduction

Latency
Latency of an optical filter module is the measured time to transmit the data
signal from the multiplexer ingress port to the multiplexer egress port or from the
demultiplexer ingress port to the demultiplexer egress port.
Figure 3 illustrates the latency of optical filter modules.

Figure 3: Latency of an Optical Filter Module


Mux Demux

Cx‐M Cx‐D
N‐M N‐D

Latency Latency
Time for passing  Time for passing 
through the data  through the data 
signal from  signal from 
multiplexer ingress  demultiplexer ingress 
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

port to multiplexer  port to demultiplexer 
egress port egress port

Optical Power Measurement


The optical interfaces of all channel modules, amplifiers and all pluggable
transceivers feature optical input power (OPR) as well as optical output power
(OPT) measurements. Besides the optical output power and receiver sensitivity
range, the measurement accuracy and optical input power measurement range
are given for every of the above mentioned optical interfaces. Due to the
accuracy of the inbuilt optical input power measurement this feature must not be
used for leveling the input power during installation. OPR and OPT are means
for monitoring changes of the output and input power values as indication of e.g.
degradation of the transmitter or the insertion loss of the attached fiber. The
physical performance monitoring capability of channel modules and amplifiers
displays the current optical power and records the low, mean and maximum
values in predefined time intervals. OPR / OPT too high and OPR / OPT too low
alarms are raised if the respective power value cross the associated alarm
threshold. The OPT too high and too low alarm thresholds are fixed and cannot
be adjusted, whereas the OPR too high and too low alarm thresholds are user
configurable within the default OPR too high and too low threshold range. The
fixed OPT thresholds and the default OPR thresholds are outside the transmitter
output power range and optical receiver dynamic range takes the accuracy of
the power measurement into account. In most cases this tolerance is +/- 3dB,
but for some interfaces it is less in case of better measurement accuracy.

Module and System Specification 67


68
Module and System Specification
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Chapter 2

Shelves and Components


This chapter describes the shelves and components of the FSP 3000R7.
The descriptions of the discontinued shelves can be found in a former version of
the FSP 3000R7 Module and System Specification.
The following sections are provided:
“SH9HU” on p. 71
“PSU/9HU-DC” on p. 73
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

“PSU/9HU-AC” on p. 75
“FAN/9HU” on p. 78
“CEM/9HU” on p. 79
“SH7HU” on p. 82
“SH7HU-R” on p. 84
“PSU/7HU-DC” on p. 86
“PSU/7HU-AC” on p. 88
“PSU/7HU-DC-HP” on p. 90
“PSU/7HU-AC-HP” on p. 92
“PSU/7HU-R-DC” on p. 94
“PSU/7HU-R-DC-HP” on p. 96
“PSU/7HU-AC-800” on p. 98
“FAN/Plug-In” on p. 101
“SH1HU-HP/2DC” on p. 103
“SH1HU-HP/E-TEMP/2DC” on p. 106
“SH1HU-F/2DC” on p. 111
“SH1HU-R” on p. 113
“SH1HU-R/PF” on p. 115
“PSU/1HU-R-AC” on p. 117

Module and System Specification 69


“PSU/1HU-R-AC-200” on p. 120
“PSU/1HU-R-DC-200” on p. 123
“FAN/1HU” on p. 126
“SH1HU/PASSIVE/FT” on p. 127
“FMT/1HU” on p. 128
“OTDR” on p. 129

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

70 Module and System Specification


Chapter 2 Shelves and Components

SH9HU
The 9HU Shelf (SH9HU) features 22 slots. Slots 1 through 20 are 4 HP wide
and 5 HU high. Slots A and B are the two leftmost slots. They are half the height
of all other slots. These slots are predetermined for the Shelf Control Unit (SCU
and SCU-II) and Network Element Control Unit (NCU-II). Instead of installing an
NCU-II into slot A, two NCU-II-P modules can be installed into the shelf. The two
NCU-II-P modules are used to protect against communication failures. These
modules are full-height modules and have to be placed into slot 3 and 18.
Please note: The installation of a NCU-II-P always requires the installation of a
second standby NCU-II-P in the same shelf. If only one NCU-II-P is installed, an
alarm will be generated.
The power supply units have to be plugged in the slots 1 and 2 or 19 and 20 (or
both). All other modules of the FSP 3000R7 can be plugged anywhere in slots 3
through 18.

To achieve power redundancy the PSU/7HU-AC-HP and


PSU/7HU-AC-800 can be mixed in one shelf. Other combinations are
PS

not allowed. The supported power supplies may provide different


output power. Therefore the shelf operates with redundant power
Note
limited by the lower-rated PSU.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

A mix of one PSU/9HU-AC and one PSU/9HU-DC per 9HU Shelf is


PS

supported.
Note

The SH9HU can be equipped with the following management modules:


• Network Element Control Unit
o
NCU-II in slot A
o
NCU-II-P in slot 3 and 18 for redundant configurations
• Shelf Control Unit
o SCU in slot B
o SCU-II in slot B
An FSP 3000R7 shelf is called:
• master shelf if it is equipped with one NCU-II and one SCU/SCU-II (for
non-redundant configurations)
• master shelf if it is equipped with two NCU-II-P modules (for redundant NCU
configurations) and one SCU-II
• main shelf if it is equipped with one SCU/SCU-II only

Module and System Specification 71


SH9HU

Following network configurations are not allowed:

PS
• using NCU-II together with NCU-II-P
Note • using NCU-II-P together with SCU/SCU-S

Channel modules working in a protection group for channel module protection


do not need to be positioned in neighboring slots.
Three of the fan plug-ins (FAN/9HU) are required to operate a 9HU Shelf. Each
of them is separately exchangeable.They can be exchanged in less than one
minute. The fan plug-ins are located at the top of the shelf.

Table 10: General Information


Equipment type SH9HU
First release 9.2
Width (dimension without adaptor 446 mm (17.56”)
brackets and front cover)
Height 399 mm (15.71”)
Depth (dimension without adaptor 276 mm (10.86”)
brackets)
Weight with three FAN/9HUs and a approx. 16.2 kg (35 lbs)
CEM/9HU, all slots unpopulated

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Max. weight with three FAN/9HUs approx. 32 kg (70 lbs)
and a CEM/9HU, all slots are fully
populated
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
GR-63, Issue 4:2012 NEBS Use of supplied NEBS-KIT/9HU
requirement required
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 1,204,268 h
Number of half size slots 2
Number of full size slots 20
Power supply (two fully redundant PSU/9HU-DC, PSU/9HU-AC,
power supplies possible) PSU/7HU-AC-HP, PSU/7HU-AC-800
Fan 3 x FAN/9HU
Applicable management modules NCU-II, NCU-II-P, SCU, SCU-II

72 Module and System Specification


Chapter 2 Shelves and Components

PSU/9HU-DC
The PSU/9HU-DC is a two slot, plug-in DC power supply unit specifically
designed for a 9HU Shelf (SH9HU). Up to two power supplies can be installed
into the shelf. If two power supplies are installed load sharing and redundancy
are supported. As opposed to the PSU/7HU-DC the PSU/9HU-DC has no DC
power terminal on the faceplate. The DC power terminals are located on the
SH9HU. A mix of one PSU/9HU-AC and one PSU/9HU-DC per shelf is
permitted.

Pay attention that for permanent power redundancy the total


maximum power consumption of the modules installed in an
PS

SH9HU Shelf does not exceed the maximum output power of the
Note PSU/9HU-DC.

Table 11 provides general information about the PSU/9HU-DC and its


environment.

Table 11: General Information


Equipment type PSU9HU-DC
First release 9.2
Width 8 HP
Height 5 HU
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Weight 1.9 kg (4 lbs)


Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 516,553 h
Slot positions SH9HU: 1+2 and 19+20

Table 12 lists all electrical specifications concerning the PSU/9HU-DC.

Table 12: Electrical Specifications


Power cord min. AWG 10, use of the cable
delivered by ADVA Optical Networking
is mandatory
Input voltage -36 V to -72 V DC
Maximum input current 30 A at -40 V DC
Inrush current does not exceed nominal current
Nominal power consumption 1165 W at -48 V DC
Max. power consumption under 1200 W
worst case conditions
Max. output power 1000 W
Nominal output voltage 12.2 V

Module and System Specification 73


PSU/9HU-DC

Table 12: Electrical Specifications (Continued)


Max. output current 83.3 A
Recommended external circuit min. 35 A hydraulic magnetic circuit
breaker for full load conditions breaker, characteristic curve C, D
according to IEC/EN 60898 or similar,
50 A thermic circuit breaker.

Risk of electric shock or burns!


The protective grounding terminal must be used for altitudes
above 2000 m (1.24 mi.) and for voltages equal to or greater than
WARNING 60 V.

If the power supply is operated in the range of -36 V to -40 V the


PS

output power must not exceed 925 W.


Note

The following tables provide information about fault monitoring of the module.

Table 13: Fault Monitoring Input


Alarm set interval (undervoltage) 32 V to 35 V

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Alarm clear interval (undervoltage) 34 V to 37 V
Turn off undervoltage interval 30 VAC to 34 VAC
Turn on undervoltage interval 31.5 VAC to 35.9 VAC

Table 14: Fault Monitoring Output


Output voltage > 13.7 V; < 10.8 V
Output current > 83.3 A

Table below provides information about performance monitoring of the module.

Table 15: Performance Monitoring


Output monitoring output current
Digital monitoring input voltage alarm (input voltage failure)
severe PSU failure (voltage out of range)
Temperature module temperature in °C

74 Module and System Specification


Chapter 2 Shelves and Components

PSU/9HU-AC
The PSU/9HU-AC is a two slot, plug-in AC power supply unit specifically
designed for the 9HU Shelf (SH9HU). Up to two power supplies can be installed
into the shelf. If two power supplies are installed load sharing and redundancy
are supported. A mix of one PSU/9HU-AC and one PSU/9HU-DC per shelf is
permitted.

1 The PSU/9HU-AC has to be powered by an alternating


current (AC) source directly provided from the mains supply.
It is not intended to be powered by AC derived from a direct
current (DC) source.
PS

2 To maintain correct power redundancy the maximum power


Note consumption of the modules installed in an SH9HU Shelf
should not exceed the maximum output power of the
PSU/9HU-AC.

Table 16 provides general information about the PSU/9HU-AC and its


environment.

Table 16: General Specifications


Equipment type PSU9HU-AC
First release 12.1
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Width 8 HP
Height 5 HU
Weight 1.65 kg (3.6 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1e
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 381,274 h
Slot positions SH9HU: 1+2 and 19+20

Table 17 provides information about the power cords.

Table 17: Power Cords


Female coupler AC Appliance Coupler
according to IEC/EN 60320/C19
Power cord North America plug type: NEMA 5-15P,
wall plug rating: 125 VAC, 15A,
device plug: IEC 60320 C19, right
angled,
min. power cord rating: 
SJTW 14AWG*3C, 125 VAC, 15 A,
with hot, neutral and ground
conductors, UL, C-UL (CSA)

Module and System Specification 75


PSU/9HU-AC

Table 17: Power Cords (Continued)


Power cord Continental Europe1 plug type: CEE 7/7
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 VAC, 10 A,
H05VV-F, 105°C, 3-pole
Power cord United Kingdom plug type: BS1363
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 VAC, 10 A,
H05VV-F, 105°C, 3-pole
fuse type: 10 A
Power cord International plug type: according to your local and
national electrical codes with L, N and
PE pin
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 V AC, 10 A
1. excepting Switzerland and Denmark

Table 18 lists the electrical specifications for the PSU/9HU-AC.

Table 18: Electrical Specifications


Recommended external circuit min. current rating:
breaker for full load conditions 16 A, type B or C, at 100 VAC to
(Each PSU/9HU-AC should have its 127 VAC
own dedicated, fused-branch 16 A, type B or C, at 220 VAC to

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
circuit.) 240 VAC
Input
AC-input type Autoranging input
Rated input voltage 100 V to 240 V AC
Input voltage range 90 V to 264 V AC
Input frequency 47 Hz to 63 Hz
Active PFC > 0.97 (pursuant to EN 61000-3-2).
Measured at 100/230 Vac, rated laod.
Maximum input current 12.5 A at 100 V AC full load and 
5.4 A at 230 V AC full load
Rated input current 11.8 A at 100 V AC full load and 
5.4 A at 240 V AC full load
Inrush current (1 ms after power on) <38 A at 264 V AC
Power
Typical power consumption 1110 W
Maximum power consumption 1160 W
under worst case conditions
Standby power consumption 5 W at 100 -127 VAC
4 W at 220 -240 VAC
Output
Nominal output voltage 12.2 V (+/- 2.5%)
Minimum output current 0A
Maximum output current 82.0 A at 12.2 V

76 Module and System Specification


Chapter 2 Shelves and Components

Table 18: Electrical Specifications (Continued)


Maximum output power 1000 W
Minimum hold-up time 10 ms

Table 19 provides information about efficiency values.


Table 19: Typical Efficiency
Load 115 V AC 230 V AC
100% load 88.0% 90.0%
50% load 91.0% 92.5%
20% load 90.0% 91.5%

The efficiency values meet the requirements of the 80PLUS® Energy Star
class: “Gold”
Table 20 provides information about fault monitoring input for the PSU/9HU-AC.

Table 20: Protection


Turn off undervoltage interval 70 VAC to 78 VAC
Turn on undervoltage interval 75 VAC to 85 VAC
Turn off overvoltage set point > 280 VAC
Turn on overvoltage set point < 275 VAC
Alarm set interval (undervoltage) 80 V to 88 V
Alarm clear interval (undervoltage) 85 V to 90 V
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Overtemperature alarm set point 75 °C module temperature


Overtemperature turn off set point 78 °C module temperature
Recover from Overtemperature turn off 72 °C module temperature
set point
Output overvoltage turn off interval > 14.1 V; < 15.3 V (latching)
Output overcurrent interval 90 A to 100 A
Output overcurrent alarm set point 82 A
Output short circuit Hiccup mode

Table 21 provides information about performance monitoring for the


PSU/9HU-AC.

Table 21: Performance Monitoring


Input monitoring Input voltage
Input current
Output monitoring Output current
Temperature module temperature in °C

Table 22 provides information about fault monitoring for the PSU/9HU-AC.

Table 22: Fault Monitoring


Voltage input voltage alarm (input voltage failure)
severe PSU failure (voltage out of range)
Current output overcurrent alarm
Temperature overtemperature alarm

Module and System Specification 77


FAN/9HU

FAN/9HU
The FAN/9HU for the SH9HU is a plug-in unit located above the module slots
and the CEM/9HU. Three of these fans are required to operate a 9HU Shelf.
Each of them is individually replaceable. A hinged handle on the front of the
panel supports an easy remove. The FAN/9HU are speed controlled fans which
exhaust the air from all slots for cooling of the FSP 3000R7 modules. They are
attached directly to the backplane with a backplane connector and are fed by
the power supplies of the shelf. A controller module allows access from the
management system. The front panel of the FAN/9HU unit has one status LED.
Table 23 contains general information about the FAN/Plug-In and its
environment.

Table 23: General Information


Equipment type FAN9HU
First release 9.2
Dimensions for use in the SH9HU
Weight 1.1 kg (2 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Air filter pad replacement intervals A dirty air filter pad negatively
influences cooling efficiency. Taking air
pollution into consideration, replace
dirty air filter pads at least once a year.
ADVA Optical Networking strongly
recommends replacing the air filter pad
every 90 days.
Typ. power consumption 9 W (full loaded shelf and 27°C ambient
temperature)
Max. power consumption 56 W
MTBF at 25°C ambient temperature 7,345,159 h
Slot positions slot above the CEM/9HU
Mean time to replace < 1 min

This table provides information about the fan data.

Table 24: Fan Data


Number of fans 3
Fan rotation speed 3000 to 7400 rpm temperature
controlled

The following table lists all kinds of indicators of the FAN/9HU.

Table 25: Indicator


Number of LEDs 1
Fan status LED to visualize fan status

78 Module and System Specification


Chapter 2 Shelves and Components

CEM/9HU
The CEM/9HU (Common Equipment Module for the 9HU Shelf) is a plug-in unit.
It is located between the module slots and the FAN/9HU in an SH9HU shelf.
The CEM/9HU includes the Fan Control Unit (FCU), LED signaling and
alarm-LED control, LCD and foil pushbuttons. It provides the combined
functionality of the PSCU (4 ports) and the UTM (3 x RJ45 + 16 x In + 4 x Out).
One CEM/9HU is required per 9HU Shelf.
The front panel of the CEM/9HU has the following LEDs:
• Network Element alarm status LEDs
• Module status LED
• Slot status LEDs for slots A, B, 1 to 20
• Telemetry port LEDs 1 - 20
• Interconnect port LEDs 1 - 4
• Ethernet port LAN LEDs 1 - 3
In addition the shelf number can be set via push buttons to be displayed on the
front panel.
Table 26 shows general information about the CEM/9HU and its environment.

Table 26: General Information


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Equipment type CEM9HU


First release 9.2
Dimensions for use in an SH9HU:
50.8 mm x 444 mm x 236 mm
Height 50.8 mm (1.14 HU)
Weight 1 kg (2.3 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Typ. power consumption 7W
Max. power consumption 8 W (all LEDs turned on for lamp test)
MTBF at 25°C ambient temperature 322,623 h
Placement between module slots and FAN/9HU

This table provides information about the telemetry interface.

Table 27: Telemetry Interface


Number of interfaces 1
Connector type HD SUB-D 44

Module and System Specification 79


CEM/9HU

Table 27: Telemetry Interface (Continued)


Cable type proprietary cable,
25 m (984.25”) link distance,
shielded,
stranded copper wire with a diameter
of 1.1 mm (0.043”),
AWG24,
compliant to UL1061, UL2464 and 
VDE 0881
Number of alarm inputs 16
Number of alarm outputs 4

The following table shows information about telemetry alarm input parameters.

Table 28: Telemetry Alarm Input Parameters


Description Pin pairs connected to an opto coupler
isolated voltage source (from DC-DC
converter). Inputs can be configured to
create an alarm if a contact is closed or
opened.
Max. voltage on open input pin < 5 V DC
Max. current through a closed < 15 mA
external switch
Alarms Inputs can be configured to create an

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
alarm if the contact is closed or opened.

This table provides information about telemetry alarm output parameters.

Table 29: Telemetry Alarm Output Parameters


Max. switching voltage < 42 V AC, < 60 V DC
Max. switching power < 50 VA AC, < 60 W DC
Min. permissible load > 10 µA at 10 mV DC
Max. contact resistance < 50 mOhm
Max. operating frequency < 1800 op/hr

The following table contains information about the ethernet interfaces.

Table 30: Ethernet Interfaces


Number of interfaces 3
Electrical connector type RJ45
Cable category CAT5E
Cable type unshielded for cable length: < 3 m
shielded (S/FTP) for cable length: 3 m to 100 m
Performance 10/100 Mbit/s Fast Ethernet half/full duplex
10/100 Mbit/s auto-negotiation can be disabled
Automatic MDI/MDI-X crossover capabilities

80 Module and System Specification


Chapter 2 Shelves and Components

The following table contains information about the interconnect ports.

Table 31: Ports


Number of interfaces 4
Interface types Support of 4 management interfaces
(interconnect ports) for monitoring,
controlling and powering 40CSM/2HU
and 96CSM/4HU-#19600-#19125
shelves

The following table contains information about the hardware reset possibility.

Table 32: Reset


Alarm reset Push-button

This table gives information about the module monitoring.

Table 33: Module Monitoring


Temperature board temperature in °C
Voltage power fail
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 81


SH7HU

SH7HU
The 7HU Shelf (SH7HU) features 22 slots. Slots 1 through 20 are 4 HP wide
and 5 HU high. Slots A and B are the two leftmost slots. They are half the height
of all other slots. These slots are predetermined for the Shelf Control Unit
(SCU/SCU-II) and Network Element Control Unit (NCU, NCU-II). All other
modules of the FSP 3000R7 system can be plugged in anywhere in slots 1
through 20.
The SH7HU can be equipped with the following management modules:
• Network Element Control Unit (NCU, NCU-II in slot A)
• Shelf Control Unit
o
SCU in slot B
o
SCU-II in slot B
o
SCU-II in slot A and B for redundant configurations but only in the main
shelves
An FSP 3000R7 shelf is called:
• master shelf if it is equipped with one NCU/NCU-II and one SCU/SCU-II
• main shelf if it is equipped with one SCU/SCU-II
• main shelf if it is equipped with two SCU-II modules only (for redundant
SCU configurations)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
For redundant SCU-II configurations in an SH7HU main shelf it is
PS

mandatory that the master shelf is a SH9HU shelf equipped with


NCU-II-P.
Note

Channel modules working in a protection group for channel module protection


do not need to be positioned in neighboring slots.
The SH7HU may optionally be powered by hot-swap AC or DC power supply
units. Power is available from the front side of the shelf. For power redundancy,
two independent power supply units connected to separate power sources are
needed.

To achieve power redundancy the PSU/7HU-AC, PSU/7HU-DC,


PSU/7HU-DC-HP and PSU/7HU-AC-HP can be mixed in one shelf. It
is also possible to mix the PSU/7HU-AC-HP and PSU/7HU-AC-800.
PS

Other combinations are not allowed. The supported power supplies


Note may provide different output power. Therefore the shelf operates with
redundant power limited by the lower-rated PSU.

82 Module and System Specification


Chapter 2 Shelves and Components

The FAN/Plug-In unit of the SH7HU is a plug-in module, which can be


exchanged in less than one minute. It is located at top of the shelf.

Table 34: General Information


Equipment type SH7HU
First release 7.0
Width (dimension without adaptor 452 mm (17.79”)
brackets and front cover)
Height 311 mm (12.25”)
Depth (dimension without adaptor 270 mm (10.63”)
brackets)
Weight with FAN/Plug-In unit, all approx. 10 kg (22 lbs)
slots unpopulated
Max. weight with FAN/Plug-In unit, approx. 26.5 kg (58 lbs)
all slots are fully populated
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient 1,514,854 h
temperature
Number of half size slots 2
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Number of full size slots 20


Power supply (two fully redundant PSU/7HU-DC, PSU/7HU-AC,
power supplies possible) PSU/7HU-DC-HP, PSU/7HU-AC-HP,
PSU/7HU-AC-800
Fan FAN/Plug-In
Applicable management modules NCU, NCU-II, SCU, SCU-II
Maximum RAM consumption on 242 Kbytes
NCU

Module and System Specification 83


SH7HU-R

SH7HU-R
The SH7HU-R Shelf features 22 slots. The slots 1 through 20 are 4 HP wide and
5 HU high. The two slots most left are of half size height and named A and B.
These slots are predetermined for the Shelf Control Unit (SCU/SCU-II) and
Network Control Unit (NCU/NCU-II). All other modules of the FSP system with
except of the PSU/7HU-R-DC and PSU/7HU-R-DC-HP can be plugged in
anywhere in slots 1 through 20. The PSU/7HU-R-DC and PSU/7HU-R-DC-HP
have to be installed in slot 1+2 and 19+20.
PS

The SH7HU-R is exclusively designed for the use in the USA.


Note

The SH7HU-R can be equipped with the following management modules:


• Network Element Control Unit (NCU/NCU-II in slot A)
• Shelf Control Unit
o SCU in slot B
o SCU-II in slot B for non-redundant configurations
o SCU-II in slot A and B for redundant configurations but only in the main
shelves
An FSP 3000R7 shelf is called:

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• master shelf if it is equipped with one NCU/NCU-II and one SCU/SCU-II
only (for non-redundant configurations)
• main shelf if it is equipped with one SCU/SCU-II only (for non-redundant
configurations)
• main shelf if it is equipped with two SCU-II modules only (for redundant
SCU configurations)

For redundant SCU-II configurations in an SH7HU main shelf it is


PS

mandatory that the master shelf is a SH9HU shelf equipped with


NCU-II-P.
Note

Channel modules working in a protection group for channel module protection


do not need to be positioned in neighboring slots.
The SH7HU-R may optionally be powered by hot-swap AC or DC power supply
units. For power redundancy, two independent power supply units connected to
separate power sources are needed. The power plugs for PSU/7HU-R-DC and
PSU/7HU-R-DC-HP are located at the rear of the shelf for rear access. The
power plug of the PSU/7HU-AC and PSU/7HU-AC-HP is located on the front of
the power supply for front access.

84 Module and System Specification


Chapter 2 Shelves and Components

To achieve power redundancy following modules can be mixed in one


shelf:
• PSU/7HU-R-DC and PSU/7HU-R-DC-HP
• PSU/7HU-AC and PSU/7HU-AC-HP
PS

• PSU/7HU-AC-HP and PSU/7HU-AC-800


Note
Other combinations are not allowed. The supported power supplies
may provide different output power. Therefore the shelf operates with
redundant power limited by the lower-rated PSU.

The FAN/Plug-In unit of the SH7HU-R is a plug-in module, which can be


exchanged in less than one minute. It is located at the top of the shelf.

Table 35: General Information SH7HU-R


Equipment type SH7HU
First Release 7.0
Width 452 mm (17.79”), Adapter brackets for
NEBS racks available
Height 311 mm (12.25”)
Depth 299 mm (11.77”)
Weight with FAN/Plug-In unit, all approx. 10 kg (22 lbs)
slots unpopulated
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Max. weight with FAN/Plug-In unit, approx. 26.5 kg (58 lbs)


all slots are fully populated
Environmental conditions Telcordia SR-3580 level 3 (NEBS)
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 1,514,854 h
Number of half size slots 2
Number of full size slots 20
Power supply PSU/7HU-R-DC, PSU/7HU-R-DC-HP,
PSU/7HU-AC, PSU/7HU-AC-HP,
PSU/7HU-AC-800
Rear power connector (only for 2 x terminal blocks with transparent
PSU/7HU-R-DC and protective cover
PSU/7HU-R-DC-HP)
Recommended tightening torque of 1.4 Nm (12.4 lbf-in)
terminal screws
Fan FAN/Plug-In
Applicable management modules NCU, NCU-II, SCU, SCU-II
Maximum RAM consumption on 242 Kbytes
NCU

Module and System Specification 85


PSU/7HU-DC

PSU/7HU-DC
The PSU/7HU-DC is a two slot, plug-in DC power supply unit specifically
designed for a 7HU Shelf. Up to two power supplies can be installed into the
shelf. If two power supplies are installed load sharing and redundancy are
supported. For power feeding, the power supply unit has a terminal block on its
faceplate.

Pay attention that for permanent power redundancy the total


maximum power consumption of the modules installed an
PS

SH7HU Shelf does not exceed the maximum output power of the
Note PSU/7HU-DC.

Table 36 provides general information about the PSU/7HU-DC and its


environment.

Table 36: General Information


Equipment type PSU7HU-DC
First release 7.0
Width 8 HP
Height 5 HU
Weight 1.6 kg (3.5 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient 531,166 h
temperature
Maximum RAM consumption on 29 Kbytes
NCU
Slot positions SH7HU: 1+2 and 19+20

Table 37 lists all electrical specifications concerning this module.

Table 37: Electrical Specifications


Input connector DC terminal block
Recommended tightening torque of 1.4 Nm (12.4 lbf-in)
terminal screws
Power cord min. AWG 14 with jacketed cord,
min. FT1 or VW1, max. 3.05 m length
Rated voltage 48 V DC
Input voltage range -36 V to -72 V DC
Rated input current range 15 A to 7 A
Inrush current (1 ms after power on) 51 A
Nominal power consumption 480 W

86 Module and System Specification


Chapter 2 Shelves and Components

Table 37: Electrical Specifications (Continued)


Max. power consumption under 500 W
worst case conditions
Max. output power 400 W
Nominal output voltage 12.2 V
Max. output current 33.5 A
Recommended external circuit min. 16 A hydraulic magnetic circuit
breaker for full load conditions breaker, characteristic curve C, D
according to IEC/EN 60898 or similar

Table below provides information about performance monitoring of the module.

Table 38: Performance Monitoring


Output monitoring output current
Digital monitoring input voltage alarm (input voltage failure)
severe PSU failure (voltage out of range)
Temperature module temperature in °C

Risk of electric shock or burns!


The protective grounding terminal must be used for altitudes
above 2000 m (1.24 mi.) and for voltages equal to or greater than
WARNING 60 V.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

If the input voltage might rise above 60 V, a 3-conductor supply


cable with protective grounding must be used.
WARNING

Module and System Specification 87


PSU/7HU-AC

PSU/7HU-AC
The PSU/7HU-AC is a two slot, plug-in AC power supply unit specifically
designed for a 7HU Shelf. Up to two power supplies can be installed into the
shelf. If two power supplies are installed load sharing and redundancy are
supported. For power feeding, the power supply unit has an AC appliance
coupler on its faceplate.

1 The PSU/7HU-AC has to be powered by an alternating


current (AC) source directly provided from the mains supply.
It is not intended to be powered by AC derived from a direct
current (DC) source.
PS

2 To maintain correct power redundancy the maximum power


Note consumption of the modules installed in an
SH7HU/SH7HU-R Shelf should not exceed the maximum
output power of the PSU/7HU-AC.

Table 39 contains general information about the PSU/7HU-AC and its


environment.

Table 39: General Information


Equipment type PSU7HU-AC
First release 7.0

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Width 8 HP
Height 5 HU
Weight 1.3 kg (2.9 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 517,131 h
Maximum RAM consumption on 26 Kbytes
NCU
Slot positions SH7HU, SH7HU-R: 1+2 and 19+20

The following table provides information about the power cords.

Table 40: Power Cords


Female coupler AC Appliance Coupler
according to IEC/EN 60320/C13
Power cord North America plug type: NEMA 5-15P, NEMA 6-20
wall plug rating: 125 VAC, 10 A
min. power cord rating: 18/3 SVT, 125
VAC, 10 A, VW-1, 105°C with L, N and
PE pin

88 Module and System Specification


Chapter 2 Shelves and Components

Table 40: Power Cords (Continued)


Power cord Continental Europe1 plug type: CEE 7/7
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 VAC, 10 A,
H05VV-F, 105°C, 3-pole
Power cord United Kingdom plug type: BS1363
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 VAC, 10 A,
H05VV-F, 105°C, 3-pole
fuse type: 5 A or 10 A
Power cord International plug type: according to your local and
national electrical codes with L, N and
PE pin
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 V AC, 10 A
1. excepting Switzerland and Denmark

This table lists all electrical specifications concerning the PSU/7HU-AC.

Table 41: Electrical Specifications


Recommended external circuit breaker min. current rating:
for full load conditions 8 A, type B or C, at 100 -127 VAC
(Each PSU/7HU-AC should have its own 4 A, type B or C, at 220 -240 VAC
dedicated, fused-branch circuit.)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Input voltage 100 V to 240 V AC (+/- 10%)


Frequency 50 Hz to 60 Hz
Rated input current range 4.8 A to 2.1 A
Inrush current (1 ms after power on) 22 A
Nominal power consumption 480 W
Max. power consumption under worst 510 W
case conditions
Max. output power 400 W
Nominal output voltage 12.2 V
Max. output current 33.5 A

Table below provides information about performance monitoring of the module.

Table 42: Performance Monitoring


Output monitoring output current
Digital monitoring input voltage alarm (input voltage failure)
severe PSU failure (voltage out of range)
Temperature module temperature in °C

Module and System Specification 89


PSU/7HU-DC-HP

PSU/7HU-DC-HP
The PSU/7HU-DC-HP is a two slot, plug-in high power DC power supply unit
specifically designed for a 7HU Shelf. Up to two power supplies can be installed
into the shelf. If two power supplies are installed load sharing and redundancy
are supported. For power feeding, the power supply unit has a terminal block on
its faceplate.

Pay attention that for permanent power redundancy the total


maximum power consumption of the modules installed in an
PS

SH7HU Shelf does not exceed the maximum output power of the
Note PSU/7HU-DC-HP.

Table 43 contains general information about the PSU/7HU-DC-HP and its


environment.

Table 43: General Information


Equipment type PSU7HU-DC
First release 8.2
Width 8 HP
Height 5 HU
Weight 1.5 kg (3.3 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient 483,325 h
temperature
Maximum RAM consumption on 29 Kbytes
NCU
Slot positions SH7HU: 1+2 and 19+20

The following table lists all electrical specifications concerning this module.

Table 44: Electrical Specifications


Input connector DC terminal block
Recommended tightening torque of 1.4 Nm (12.4 lbf-in)
terminal screws
Power cord min. AWG 14 AWM-Style 1015
(105°C) with jacketed cord, 
max. 3.05 m length
Rated voltage 48 V DC
Input voltage range -36 V to -72 V DC
Rated input current range 21 A to 10 A
Inrush current (1 ms after power 31 A
on)

90 Module and System Specification


Chapter 2 Shelves and Components

Table 44: Electrical Specifications (Continued)


Nominal power consumption 720 W
Max. power consumption under 745 W
worst case conditions
Max. output power 600 W
Nominal output voltage 12.2 V
Max. output current 50 A
Recommended external circuit min. 22 A hydraulic magnetic circuit
breaker for full load conditions breaker, characteristic curve C, D
according to IEC/EN 60898 or similar

Table below provides information about performance monitoring of the module.

Table 45: Performance Monitoring


Output monitoring output current
Digital monitoring input voltage alarm (input voltage failure)
severe PSU failure (voltage out of range)
Temperature module temperature in °C

Risk of electric shock or burns!


The protective grounding terminal must be used for altitudes
above 2000 m (1.24 mi.) and for voltages equal to or greater than 
WARNING 60 V.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

If the input voltage might rise above 60 V, a 3-conductor supply


cable with protective grounding must be used.
WARNING

Module and System Specification 91


PSU/7HU-AC-HP

PSU/7HU-AC-HP
The PSU/7HU-AC-HP is a two slot, plug-in high power AC power supply unit
specifically designed for a 7HU Shelf and 9HU Shelf. Up to two power supplies
can be installed into the shelf. If two power supplies are installed load sharing
and redundancy are supported. For power feeding, the power supply unit has an
AC appliance coupler on its faceplate.

1 The PSU/7HU-AC-HP has to be powered by an alternating


current (AC) source directly provided from the mains supply.
It is not intended to be powered by AC derived from a direct
current (DC) source.
PS

2 To maintain correct power redundancy the maximum power


Note consumption of the modules installed in an
SH7HU/SH7HU-R or SH9HU Shelf should not exceed the
maximum output power of the PSU/7HU-AC-HP.

Table 46 contains general information about the PSU/7HU-AC-HP and its


environment.

Table 46: General Information


Equipment type PSU7HU-AC
First release 8.2

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Width 8 HP
Height 5 HU
Weight 1.5 kg (3.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 467,727 h
Maximum RAM consumption on 26 Kbytes
NCU
Slot positions SH7HU, SH7HU-R, SH9HU: 1+2 and
19+20

The following table provides information about the power cords.

Table 47: Power Cords


Female coupler AC Appliance Coupler
according to IEC/EN 60320/C13
Power cord North America plug type: NEMA 5-15P, NEMA 6-20
wall plug rating: 125 VAC, 10 A
min. power cord rating: 18/3 SVT, 125
VAC, 10 A, VW-1, 105°C with L, N and
PE pin

92 Module and System Specification


Chapter 2 Shelves and Components

Table 47: Power Cords (Continued)


Power cord Continental Europe1 plug type: CEE 7/7
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 VAC, 10 A,
H05VV-F, 105°C, 3-pole
Power cord United Kingdom plug type: BS1363
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 VAC, 10 A,
H05VV-F, 105°C, 3-pole
fuse type: 5 A or 10 A
Power cord International plug type: according to your local and
national electrical codes with L, N and
PE pin
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 V AC, 10 A
1. excepting Switzerland and Denmark

This table lists all electrical specifications concerning this module.

Table 48: Electrical Specifications


Recommended external circuit breaker min. current rating:
for full load conditions 10 A, type B or C, at 100 -127 VAC
(Each PSU/7HU-AC-HP should have 5 A, type B or C, at 220 -240 VAC
its own dedicated, fused-branch
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

circuit.)
Input voltage 100 V to 240 V AC (+/- 10%)
Frequency 50 Hz to 60 Hz
Rated input current range 7.2 A to 3 A
Inrush current (1 ms after power on) 7.5 A
Nominal power consumption 720 W
Max. power consumption under worst 730 W
case conditions
Max. output power 600 W
Nominal output voltage 12.2 V
Max. output current 50 A

Table below provides information about performance monitoring of the module.

Table 49: Performance Monitoring


Output monitoring output current
Digital monitoring input voltage alarm (input voltage failure)
severe PSU failure (voltage out of range)
Temperature module temperature in °C

Module and System Specification 93


PSU/7HU-R-DC

PSU/7HU-R-DC
The PSU/7HU-R-DC is a plug-in DC power supply unit specifically designed for
an SH7HU-R Shelf. Up to two power supplies can be installed into the shelf. If
two power supplies are installed load sharing and redundancy are supported.
This power supply has no terminal block on its faceplate. For power feeding, the
3-pin input power connector of the unit connects to the corresponding connector
on the backplane. This connector is electrically linked with the external terminal
block at the rear of the shelf.

1 The PSU/7HU-R-DC is exclusively designed for the use in


the USA.
PS

2 Pay attention that the total maximum power consumption of


Note
the modules installed in an SH7HU-R Shelf does not exceed
the maximum output power of the PSU/7HU-R-DC.

Table 50 provides general information on the PSU/7HU-R-DC and its


environment.

Table 50: General Information PSU/7HU-R-DC


Equipment type PSU7HU-DC
First Release 7.0

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Width 8 HP
Height 5 HU
Weight 1.3 kg (2.9 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS)
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient 827,130 h
temperature
Maximum RAM consumption on 29 Kbytes
NCU
Slot positions SH7HU-R: 1+2 and 19+20

Table 51 lists all electrical specifications concerning this module.

Table 51: Electrical Specifications


Power cord at the shelf min. AWG 16 with jacketed cord,
min. FT1 or VW1, max. 3.05 m length
Input voltage range -40 V to -57 V DC
Rated input current range 15 A to 7 A
Inrush current (1 ms after power on) 51 A
Nominal power consumption 480 W
Max. power consumption under 540 W
worst case conditions
Max. output power 400 W

94 Module and System Specification


Chapter 2 Shelves and Components

Table 51: Electrical Specifications (Continued)


Nominal output voltage 12.2 V
Max. output current 33.5 A
Recommended external circuit min. 16 A hydraulic magnetic circuit
breaker for full load conditions breaker, characteristic curve C, D
according to IEC/EN 60898 or similar

Table below provides information about performance monitoring of the module.

Table 52: Performance Monitoring


Output monitoring output current
Digital monitoring input voltage alarm (input voltage failure)
severe PSU failure (voltage out of range)
Temperature module temperature in °C
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 95


PSU/7HU-R-DC-HP

PSU/7HU-R-DC-HP
The PSU/7HU-R-DC-HP is a plug-in high power DC power supply unit
specifically designed for an SH7HU-R Shelf. Up to two power supplies can be
installed into the shelf. If two power supplies are installed load sharing and
redundancy are supported.
This power supply has no terminal block on its faceplate. For power feeding, the
3-pin input power connector of the unit connects to the corresponding connector
on the backplane. This connector is electrically linked with the external terminal
block at the rear of the shelf.

1 The PSU/7HU-R-DC-HP is exclusively designed for the use


in the USA.
PS

2 Pay attention that the total maximum power consumption of


Note
the modules installed in an SH7HU-R Shelf does not exceed
the maximum output power of the PSU/7HU-R-DC-HP.

Table 53 contains general information on the PSU/7HU-R-DC-HP and its


environment.

Table 53: General Information PSU/7HU-R-DC-HP


Equipment type PSU7HU-DC
First Release 8.2

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Width 8 HP
Height 5 HU
Weight 1.5 kg (3.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS)
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 483,325 h
Maximum RAM consumption on 29 Kbytes
NCU
Slot positions SH7HU-R: 1+2 and 19+20

The following table lists all electrical specifications concerning this module.

Table 54: Electrical Specifications


Power cord min. AWG 14 AWM-Style 1015 (105°C)
with jacketed cord, max. 3.05 m length
Input voltage range -40 V to -57 V DC
Rated input current range 21 A to 10 A
Inrush current (1 ms after power 31 A
on)
Nominal power consumption 720 W
Max. power consumption under 745 W
worst case conditions

96 Module and System Specification


Chapter 2 Shelves and Components

Table 54: Electrical Specifications (Continued)


Max. output power 600 W
Nominal output voltage 12.2 V
Max. output current 50 A
Recommended external circuit min. 20 A hydraulic magnetic circuit
breaker for full load conditions breaker, characteristic curve C, D
according to IEC/EN 60898 or similar

Table below provides information about performance monitoring of the module.

Table 55: Performance Monitoring


Output monitoring output current
Digital monitoring input voltage alarm (input voltage failure)
severe PSU failure (voltage out of range)
Temperature module temperature in °C
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 97


PSU/7HU-AC-800

PSU/7HU-AC-800
The PSU/7HU-AC-800 is a two slot, plug-in AC power supply unit specifically
designed for an SH7HU/SH7HU-R Shelf. It can also be used by an SH9HU
Shelf. Up to two power supplies can be installed into the shelf. If two power
supplies are installed load sharing and redundancy are supported. For power
feeding the power supply unit has an AC appliance coupler on its faceplate.

1 The PSU/7HU-AC-800 has to be powered by an alternating


current (AC) source directly provided by the mains. It is not
intended to be powered by AC derived from a direct current
(DC) source.
PS

2 To maintain correct power redundancy the maximum power


Note
consumption of the modules installed in an
SH7HU/SH7HU-R or SH9HU Shelf does not exceed the
specified value of the maximum output power of the
PSU/7HU-AC-800.

Table 56 contains general information about the PSU/7HU-AC-800 and its


environment.

Table 56: General Information


Equipment type PSU7HU-AC

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
First release 11.1
Width 8 HP
Height 5 HU
Weight 1.5 kg (3.3 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient 403,197 h
temperature
Maximum RAM consumption on 26 Kbytes
NCU
Slot positions SH7HU, SH7HU-R: 1+2 and 19+20
SH9HU: 1+2 and 19+20

98 Module and System Specification


Chapter 2 Shelves and Components

The following table provides information about the power cords.

Table 57: Power Cords


Female coupler AC Appliance Coupler
according to IEC/EN 60320/C13
Power cord North America plug type: NEMA 5-15P, NEMA 6-20
wall plug rating: 125 VAC, 10 A
min. power cord rating: 18/3 SVT, 125
VAC, 10 A, VW-1, 105°C with L, N and
PE pin
Power cord Continental Europe1 plug type: CEE 7/7
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 VAC, 10 A,
H05VV-F, 105°C, 3-pole
Power cord United Kingdom plug type: BS1363
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 VAC, 10 A,
H05VV-F, 105°C, 3-pole
fuse type: 6 A or 10 A
Power cord International plug type: according to your local and
national electrical codes with L, N and
PE pin
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 V AC, 10 A
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

1. excepting Switzerland and Denmark

This table lists all electrical specifications concerning this module.

Table 58: Electrical Specifications


Recommended external circuit min. current rating:
breaker for full load conditions 13 A, type B or C, at 100 - 127 VAC
(Each PSU/7HU-AC-800 should have 10 A, type B or C, at 220 - 240 VAC
its own dedicated, fused-branch
circuit.)
Input voltage 100 V to 240 V AC (+/- 10%)
Frequency 50 Hz to 60 Hz
Rated input current 9 A to 4 A
Inrush current (1 ms after power on) 3.5 A
Nominal power consumption 870 W at 240 V
910 W at 100 V
Max. power consumption under worst 915 W
case conditions
Max. output power 800 W
Nominal output voltage 12.2 V
Max. output current 65.6 A

Module and System Specification 99


PSU/7HU-AC-800

The following tables provide information about fault monitoring of the module.

Table 59: Fault Monitoring Input


Alarm set interval (undervoltage) 80 V to 88 V
Alarm clear interval (undervoltage) 80 V to 89.9 V
Turn off undervoltage interval 70 VAC to 78 VAC
Turn on undervoltage interval 75 VAC to 85 VAC

Table 60: Fault Monitoring Output


Output voltage > 13.7 V; < 10.8 V
Output current > 65.6 A

Table below provides information about performance monitoring of the module.

Table 61: Performance Monitoring


Output monitoring output current
Digital monitoring input voltage alarm (input voltage failure)
severe PSU failure (voltage out of range)
Temperature module temperature in °C

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

100 Module and System Specification


Chapter 2 Shelves and Components

FAN/Plug-In
The FAN/Plug-In for the SH7HU and SH7HU-R is a plug-in module located atop
the slots. It has three speed controlled fans which exhaust the air from all slots
for cooling of the FSP 3000R7 modules. It is attached directly to the backplane
with a backplane connector and is fed by the power supplies of the shelf. A
controller module allows access from the management system.
The front panel of the FAN/Plug-In unit has the following LEDs:
• Network Element status LEDs
• Fan status LED (fan)
• Slot status LEDs for slots A,B, 1 to 20
In addition the shelf number can be set via push buttons to be displayed on the
front panel.
Table below contains general information about the FAN/Plug-In and its
environment.

Table 62: General Information


Equipment type FCU7HU
First release 7.0
Dimensions for use in the SH7HU
Weight 2.3 kg (5 lbs)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Environmental conditions Telcordia SR-3580 level 3 (NEBS),


ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Air filter pad replacement intervals A dirty air filter pad negatively
influences cooling efficiency. Taking air
pollution into consideration, replace
dirty air filter pads at least once a year.
ADVA Optical Networking strongly
recommends replacing the air filter pad
every 90 days.
Typ. power consumption 12 W (25°C ambient temperature)
Max. power consumption 30 W
MTBF at 25°C ambient temperature 658,309 h
Slot position SH7HU, SH7HU-R: venting slot atop of
module slots
Mean time to replace < 1 min

This table provides information about the fan data.

Table 63: Fan Data


Number of fans 3
Fan rotation speed 1100 to 3300 rpm temperature
controlled

Module and System Specification 101


FAN/Plug-In

The failure of a single fan does not endanger the cooling of the
modules in the shelf up to 45°C ambient temperature. However,

PS
the whole plug-in fan unit should be replaced by Service
Personnel at the earliest opportunity. If two fans fail, the plug-in
Note
fan unit should be replaced within 48 hours after fan failure.

The following table lists all kinds of indicators of the FAN/Plug-In.

Table 64: Indicators


LCD display 28.1 mm x 16.7 mm graphical display
used for Shelf ID (1 to 20, 1E to 20E)
Network Element status LEDs Critical (red)
(only used in master shelf with Major (yellow)
NCU) Minor (yellow)
Slot status LEDs for slots A, B, 1 to one for each of the 22 slots below to
20 visualize slot status
Fan status LED to visualize fan status

This table gives information about the available push buttons of the
FAN/Plug-In.

Table 65: Operating Elements


Push buttons for setting Shelf ID Up, Down and Set

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

102 Module and System Specification


Chapter 2 Shelves and Components

SH1HU-HP/2DC
The SH1HU-HP/2DC (1HU Shelf High Power with redundant DC PSU) is a
rack-mountable, 1 HU-high, DC-powered shelf, which includes an entire 
FSP 3000R7 system. The internal power supply is integrated on the left side.
Six individual fans ensure the effective cooling of the modules. The
SH1HU-HP/2DC shelf provides an increased power output and a large increase
in airflow. This is required for using 10PCA-PCN-1G3+10G modules.
The SH1HU-HP/2DC shelf features 4 slots. Slots 1 and 2 are 4 HP wide and 5
HU high. The remaining two slots are half the height of the other slots and
named A and B. These slots are predetermined for the SCU/SCU-S/SCU-II and
NCU-II/NCU. All other modules of the FSP 3000R7 system can be plugged in
anywhere in slots 1 and 2.
The SH1HU-HP/2DC can be equipped with the following management modules:
• Network Element Control Unit (NCU-II/NCU in slot A)
• Shelf Control Unit
o
SCU/SCU-S in slot B
o
SCU-II in slot B
An FSP 3000R7 shelf is called:
• master shelf if it is equipped with one NCU-II/NCU and one
SCU/SCU-S/SCU-II
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

• main shelf if it is equipped with one SCU/SCU-S/SCU-II only


The following table shows general information about the shelf and its
environment.

Table 66: General Information


Equipment type SH1HU-DC
First release 9.2
Width (dimension without adaptor 446 mm (17.56”)
brackets)
Height 44 mm (1.72”)
Depth (dimension without adaptor 224 mm (8.82”)
brackets)
Weight all slots unpopulated 2.8 kg (6.2 lbs)
Max. weight all slots fully populated 5.5 kg (12.1 lbs)
Environmental conditions ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 695,141 h
Number of half size slots 2
Number of full size slots 2
Power supply built-in with two redundant power feeds
Fan built-in two redundant three-fan groups

Module and System Specification 103


SH1HU-HP/2DC

Table 66: General Information (Continued)


Applicable management modules NCU-II, NCU, SCU, SCU-S, SCU-II
Maximum RAM consumption on 87 Kbytes
NCU

The following table lists all electrical specifications concerning this shelf.

Table 67: Electrical Specifications


Input voltage -36 V DC to -72 V DC
Max. input current 6 A at 36 V
DC input connector 4-pole PHOENIX connector
Power cord min. AWG 16 with jacketed cord,
min. FT1 or VW1, max. 3.05 m length
Inrush current (1 ms after power on) <7A
Typ. power consumption 15 W 
(25°C ambient temperature, 48 V)
Max. power consumption 240 W
Max. output power (for plug-in modules) 170 W
Recommended external circuit breaker min. 7 A hydraulic magnetic circuit
for full load conditions breaker, characteristic curve C, D
according to IEC/EN 60898 or similar

The following table provides information about the module monitoring.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 68: Shelf Monitoring
Digital monitoring input voltage alarm
Fan fail
Temperature module temperature in °C

The following tables provide information about fan data, indicators and
operating elements.

Table 69: Fan Data


Number of fans 6
Fan rotation speed 5000 to 13000 rpm temperature
controlled

Table 70: Indicators


Seven-segments digital display 28 mm x 13 mm, used for Shelf ID
(1 to 20, 1E to 20E)
Network Element status LEDs (only Critical (red), Major (yellow)
used in master shelf with NCU) Minor (yellow)
Slot status LEDs for slots A, B, 1, 2 one for each of the 4 slots to visualize
slot status
Fan status LED to visualize fan status

104 Module and System Specification


Chapter 2 Shelves and Components

Table 71: Operating Elements


Push buttons for setting Shelf ID Up
Down
Set
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 105


SH1HU-HP/E-TEMP/2DC

SH1HU-HP/E-TEMP/2DC
The SH1HU-HP/E-TEMP/2DC is a rack-mountable, DC-powered 1 HU Shelf
High Power with dual front access power feeds. This shelf is based on the
design of the SH1HU-HP/2DC. It is primarly intended for extended low ambient
temperature operation and applications requiring higher wattage and cooling
airflow rates.
The SH1HU-HP/E-TEMP/2DC includes an entire FSP 3000R7 system. The
internal DC-input power supply is integrated on the left side. Six individual fans
ensure the effective cooling of the modules. The fans cannot be swapped. This
shelf has a built-in temperature control in order to keep the operating
temperatures for the equipped modules within the working range at ambient
temperatures down to -33°C. Therefore modules, which are used within this
shelf can be operated down to -33°C ambient temperature, independent of their
environmental temperature specification. The upper temperature limits of the
modules remain still valid.
After power fail the shelf will establish an internal temperature towards the
specified working temperature for the equipped modules and is then powering
up the modules.
The SH1HU-HP/E-TEMP/2DC shelf features 4 slots. Slots 1 and 2 are 4 HP
wide and 5 HU high. The remaining two slots are half the height of the other
slots and named A and B. These slots are predetermined for the SCU-S and
NCU-II. All other modules of the FSP 3000R7 system can be plugged anywhere

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
in slots 1 and 2.
The SH1HU-HP/E-TEMP/2DC can be equipped with the following management
modules:
• Network Element Control Unit (NCU-II only) in slot A
• Shelf Control Unit (SCU-S only) in slot B
An FSP 3000R7 shelf is called:
• master shelf if it is equipped with one NCU-II and one SCU-S
• main shelf if it is equipped with one SCU-S only

This equipment shall be installed in a lightning protection zone 2 only.


CAUTION

Table 72 provides general information about the shelf and its environment.

Table 72: General Information


Equipment type SH1HU-DC-ETEMP
First release 12.2
Width (dimension without adaptor 446 mm (17.56”)
brackets)
Height 44 mm (1.72”)

106 Module and System Specification


Chapter 2 Shelves and Components

Table 72: General Information (Continued)


Depth (dimension without adaptor 224 mm (8.82”)
brackets)
Weight all slots unpopulated 3.3 kg (6.2 lbs)
Max. weight all slots fully populated 5.5 kg (12.1 lbs)
Environmental operational ETSI EN 300 019-1-3 Class 3.31 (Non-
conditions temperature controlled, weather
protected locations, low air temperature
as many as -33°C (-27.4°F))
Degree of protection according to  IP20
IEC 60529
MTBF at 25°C ambient temperature 618,381 h
Number of half size slots 2
Number of full size slots 2
Power supply built-in with two redundant power feeds
Fan built-in two redundant three-fan groups
Applicable management modules NCU-II, SCU-S
1. For use in outdoor areas, the SH1HU-HP/E-TEMP/2DC must be
installed in a weatherproof cabinet to fulfill IP20 requirements and to
protect the shelf from dripping water, driven rain, snow, hail, etc.

Table 73 provides information about the power cords recommended for


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

connecting the SH1HU-HP/E-TEMP/2DC to the DC power sources.

Table 73: Power Cables Recommended


Order Number DC Cable Variants
1036700022 CBL/DC300/2AWG16/1HU-HP/R-/B+
1036700014 CBL/DC300/2AWG16/1HU-HP/BL-BK
1036700011 CBL/DC300/2AWG16/1HU-HP/GR-BL

Table 74 lists all electrical specifications concerning this shelf.

Table 74: Electrical Specifications


Recommended external circuit min. 7 A hydraulic magnetic circuit
breaker requirement for full load breaker, characteristic curve C, D
conditions according to IEC/EN 60898 or similar;
10 A thermic circuit breaker
Power cord min. AWG 16 with jacketed cord, min.
FT1 or VW1, max. 3.05 m length;
Use of the cables provided by ADVA
Optical Networking is recommended.
See Table 73.
Input
DC input connector 4-pole PHOENIX connector on the
front panel
Input voltage -48V DC
Rated input voltage range -36 V DC to -72 V DC

Module and System Specification 107


SH1HU-HP/E-TEMP/2DC

Table 74: Electrical Specifications (Continued)


Maximum input voltage range -36 V DC to -75 V DC
Maximum input current < 6 A at -36 V DC full load
Inrush current (1 ms after power on) < 7 A at -72 V, cool and warm status
Output
Nominal output voltage 12.0 V (+/- 0.2 % initial set point)
Hold-Up time 10 ms
Dwell time 10 ms
Power
Typ. power consumption 13 W (empty shelf, 25°C ambient
temperature, -48 V)
Nominal power consumption 225 W (at -48 V, full load)
Maximum power consumption under 230 W
worst case conditions
Maximum power output (for plug-in 170 W
modules)

Table 75 provides information about the Typical Efficiency.

Table 75: Typical Efficiency


Load -48 V DC
100% load > 93.5%

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
50% load tbd
20% load tbd

The efficiency values meet the requirements of the 80PLUS® Energy Star
class: “Platinum”.
Table 76 provides information about power-up modes.

Table 76: Power-Up Modes


Power-Up Modes
Cold startup with Cold startup time < 3 min if ambient temperature
module test is > 0°C
5 min if ambient temperature is
-33°C and shelf operating is
short-period (< 2 min)
interrupted
3 min … 90 min if ambient
temperature is 0°C … -33°C
Warm startup (reboot) Warm startup (reboot) not traffic affecting
after manual reset Warm startup < 2 min after controller reset
command time < 2 min after manual reset
command or watchdog reset

108 Module and System Specification


Chapter 2 Shelves and Components

Table 77 provides information about fault monitoring input and protection for the
SH1HU-HP/E-TEMP/2DC.

Table 77: Fault Consecutive Actions/Protection


DC failure alarm set point -32 VDC to -35 V DC
DC failure alarm clear point -34 VDC to -37 V DC
PSU turn off point -32.5 VDC to -35.0 V DC
PSU turn on point -33.5 VDC to -36.5 VDC
Turn on/off hysteresis 1.0 V to 2.0 V
Output overvoltage turn off interval 14.1 V to 15.3 V
Output overcurrent alarm set point 18.0 A to 19.7 A
Protection
Output short circuit Hiccup mode
Over temperature protection Auto-recoverable with 
5°C to 10°C hysteresis
Input overvoltage protection components single pole fuse per feed, MOS
Reverse input polarity long endurance protected

Table 78 provides information about the shelf performance monitoring.

Table 78: Performance Monitoring


Input monitoring Input voltage
Fan fail
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Temperature Shelf operating temperature in °C


Shelf air intake temperature in °C

Table 79 provides information about the fan data.

Table 79: Fan Data


Number of fans 6
Fan rotation speed 5,000 to 13,000 rpm temperature
controlled

Table 80 provides information about the indicators available on the shelf.

Table
‘s 80: Indicators
Seven-segments digital display 28 mm x 13 mm, used for Shelf ID
(1 to 20, 1E to 20E)
Network Element status LEDs (only Critical (red), Major (yellow)
used in master shelf with NCU) Minor (yellow)
Slot status LEDs for slots A, B, 1, 2 one for each of the 4 slots to visualize
slot status
Fan status LED to visualize fan status

Module and System Specification 109


SH1HU-HP/E-TEMP/2DC

Table 81 provides information about the shelf’s operating elements.

Table 81: Operating Elements


Push buttons for setting the Shelf Up
ID Down
Set

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

110 Module and System Specification


Chapter 2 Shelves and Components

SH1HU-F/2DC
The SH1HU-F/2DC features 4 slots. Slots 1 and 2 are 4 HP wide and 5 HU high.
The remaining two slots are of half size height and named A and B. These slots
are predetermined for the Shelf Control Unit (SCU/SCU-S/SCU-II) and Network
Element Control Unit (NCU/NCU-II). All other modules of the FSP 3000R7
system can be plugged in anywhere in slots 1 and 2.
The SH1HU-F/2DC can be equipped with the following management modules:
• Network Element Control Unit (NCU/NCU-II in slot A)
• Shelf Control Unit
o
SCU/SCU-S in slot B
o
SCU-II in slot B
An FSP 3000R7 shelf is called:
• master shelf if it is equipped with one NCU/NCU-II and one
SCU/SCU-S/SCU-II
• main shelf if it is equipped with one SCU/SCU-S/SCU-II only
The following table shows general information about the shelf and its
environment.

Table 82: General Information


Equipment type SH1HU-DC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

First release 8.1.1


Width (dimension without adaptor 453 mm (17.83”)
brackets)
Height 44 mm (1.72”)
Depth (dimension without adaptor 223 mm (8.78”)
brackets)
Weight all slots unpopulated 2.8 kg (6.2 lbs)
Max. weight all slots fully populated 5.5 kg (12.1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 680,470 h
Number of half size slots 2
Number of full size slots 2
Power supply built-in with two redundant power feeds
Fan built-in two redundant three-fan groups
Applicable management modules NCU, NCU-II, SCU, SCU-S, SCU-II
Maximum RAM consumption on 87 Kbytes
NCU

Module and System Specification 111


SH1HU-F/2DC

This table lists all electrical specifications concerning this shelf.

Table 83: Electrical Specifications


Input voltage range -36 V to -72 V DC
Max. input current 3.9 A at 36 V
DC input connector 4-pole DC terminal block
Recommended tightening torque of 0.8 Nm (7.08 lbf-in)
terminal screws
Power cord min. AWG 16 with jacketed cord, 
min. FT1 or VW1, max. 3.05 m length
Inrush current (1 ms after power on) < 3.5 A
Typ. power consumption 14 W 
(25°C ambient temperature, 48 V)
Max. power consumption 140 W
Max. output power (for plug-in 120 W
modules)
Recommended external circuit min. 5 A hydraulic magnetic circuit
breaker for full load conditions breaker, characteristic curve C, D 
according to IEC/EN 60898 or similar

The following table provides information about the module monitoring.

Table 84: Shelf Monitoring


Digital monitoring input voltage alarm

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Fan fail
Temperature module temperature in °C

The following tables provide information about fan data, indicators and
operating elements.

Table 85: Fan Data


Number of fans 6
Fan rotation speed 4000 to 9500 rpm temperature controlled

Table 86: Indicators


Display three 7-segment LEDs used for Shelf
ID (1 to 20, 1E to 20E)
Network Element status LEDs (only Critical (red), Major (yellow)
used in master shelf with NCU) Minor (yellow)
Slot status LEDs for slots A, B, 1, 2 one for each of the 4 slots to visualize
slot status
Fan status LED to visualize fan status
Power status LEDs to visualize DC power status
for "PWR1" and "PWR2"

Table 87: Operating Elements


Push buttons for setting Shelf ID Up
Down
Set

112 Module and System Specification


Chapter 2 Shelves and Components

SH1HU-R
The SH1HU-R of the FSP 3000R7 features 6 slots. The slots 1 and 2 are 4 HP
wide and 5 HU high. The neighboring two slots are of half size height and
named A and B. These slots are predetermined for the Shelf Control Unit
(SCU/SCU-S/SCU-II) and Network Element Control Unit (NCU/NCU-II). The
remaining two slots are dedicated AC power supply modules located in the rear
side. All other modules of the FSP 3000R7 system can be plugged in anywhere
in slots 1 and 2.
The SH1HU-R can be equipped with the following management modules:
• Network Element Control Unit (NCU-II/NCU in slot A)
• Shelf Control Unit
o
SCU/SCU-S in slot B
o
SCU-II in slot B
An FSP 3000R7 shelf is called:
• master shelf if it is equipped with one NCU-II/NCU and one
SCU/SCU-S/SCU-II
• main shelf if it is equipped with one SCU/SCU-S/SCU-II only
The following table shows general information about the shelf and its
environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 88: General Information


Equipment type SH1HU
First release 8.1.1
Width (dimension without adaptor 453 mm (17.83”)
brackets)
Height 44 mm (1.72”)
Depth (dimension without adaptor 363 mm (14.29”)
brackets, but with power supplies)
Weight all slots unpopulated 4 kg (8.8 lbs)
Max. weight all slots fully populated 9 kg (19.8 lbs)
Environmental conditions ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 1,105,076 h
Number of half size slots 2
Number of full size slots 2
Power supply two redundant pluggable power
supplies (PSU/1HU-R-AC)
Fan built-in two redundant three-fan groups
Typ. power consumption 6.5 W 
(25°C ambient temperature)
Max. power consumption (empty 12 W
shelf)

Module and System Specification 113


SH1HU-R

Table 88: General Information (Continued)


Maximum RAM consumption on 162 Kbytes
NCU
Applicable management modules NCU, NCU-II, SCU, SCU-S, SCU-II

The following table provides information about the module monitoring.

Table 89: Shelf Monitoring


Digital monitoring input voltage alarm
Fan fail
Temperature module temperature in °C

This table provides information about the fan data.

Table 90: Fan Data


Number of fans 6
Fan rotation speed 4000 to 9500 rpm temperature
controlled

The following table contains information about the available indicators of the
shelf.

Table 91: Indicators

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Display three 7-segment LEDs used for Shelf
ID (1 to 20, 1E to 20E)
Network Element status LEDs Critical (red), Major (yellow),
(only used in master shelf with NCU) Minor (yellow)
Slot status LEDs for slots A, B, 1, 2 one for each of the 4 slots to visualize
slot status
Fan status LED to visualize fan status
Power status LEDs for "pwr1" and to visualize AC power status
"pwr2"

The following table shows the available push buttons of the shelf.

Table 92: Operating Elements


Push buttons for setting Shelf ID Up, Down and Set

114 Module and System Specification


Chapter 2 Shelves and Components

SH1HU-R/PF
The SH1HU-R/PF is a rack-mountable, rear power access 1HU Shelf equipped
with a pluggable fan module, a replaceable air intake filter and redundant AC
power supplies. The shelf can be used to house any FSP 3000R7 modules. The
SH1HU-R/PF features four horizontal slots accessible from the front for
accommodating standard FSP 3000R7 modules, two half height ones for
housing management modules and two full height ones for housing traffic
modules.
The shelf also has an air filter unit which is made up of a fixed filter guide frame
and a removable frame which contains the air filter pad. The air filter guide
frame ensures sufficient space for fiber management from below (for slot 1) or
above (for slot 2) the air filter frame.

Never operate the shelf without having an air filter pad


fitted in the air filter unit. Without the filter pad in place
then dirt could enter the unit and could then block the air
inlets and outlets. Blocked air inlets and outlets will then
NOTICE lead to inefficient cooling and considerable increase in
fire risk.
A dirty air filter pad should be replaced at least once a
year. ADVA Optical Networking strongly recommends
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

replacing the air filter pad every 90 days.

The assignment of NCU and SCU type modules to the A and B slots
of this shelf are the reverse of all other 1HU Shelf types, due to the
PS

required physical placement of certain internal components of the


Note shelf.

The SH1HU-R/PF can be equipped with the following management modules:


• Network Element Control Unit (NCU or NCU-II in slot A)
• Shelf Control Unit (SCU/SCU-S/SCU-II in slot B)
An FSP 3000R7 shelf is called:
• master shelf if it is equipped with one NCU/NCU-II and one
SCU/SCU-S/SCU-II
• main shelf if it is only equipped with one SCU/SCU-S/SCU-II
The following table shows general information about the shelf and its
environment.

Table 93: General Information


Equipment type SH1HUPF
First release 10.3
Width (dimension without adaptor 446 mm (17.56”)
brackets)
Height 44 mm (1.72”)

Module and System Specification 115


SH1HU-R/PF

Table 93: General Information (Continued)


Depth (dimension without adaptor 422 mm (16.61”)
brackets and power connectors of the
power supplies)
Weight with FAN/1HU module, all 4.3 kg (9.5 lbs)
slots unpopulated
Max. weight with FAN/1HU module, 9.3 kg (20.5 lbs)
all slots are fully populated
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IEC IP20. Use in a pollution degree 2
60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 851,361 h
Number of half size slots 2
Number of full size slots 2
Power supply two redundant pluggable power
supplies (PSU/1HU-R-AC-200)
Max. power consumption 3.0 W
Fan pluggable FAN/1HU
Applicable management modules NCU, NCU-II, SCU, SCU-S, SCU-II
Maximum RAM consumption on NCU 213 Kbytes

The following table provides information about the module monitoring.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 94: Shelf Monitoring
Digital monitoring input voltage alarm
Fan fail
Temperature module temperature in °C1
1. is equivalent to the air exhaust temperature (in °C)

Table below contains information about the available indicators of the shelf.

Table 95: Indicators


Display dot matrix LCD display used for shelf ID
(1...20, 1E ... 20E)
Network Element status LEDs Critical (red), Major (yellow),
(only used in master shelf with NCU) Minor (yellow)
Slot status LEDs for slots A, B, 1, 2 one for each of the 4 slots to visualize
slot status
Fan module status LED to visualize the status of the pluggable
FAN/1HU
Power status LEDs for "pwr1" and to visualize AC power status
"pwr2"

The following table shows the available push buttons of the shelf.

Table 96: Operating Elements


Push buttons for setting Shelf ID Up, Down and Set

116 Module and System Specification


Chapter 2 Shelves and Components

PSU/1HU-R-AC
The Power Supply (PSU/1HU-R-AC) provides the power needed to operate an
SH1HU-R shelf. Up to two power supplies can be installed into the shelf. If two
power supplies are installed load sharing and redundancy are supported.

1 The PSU/1HU-R-AC has to be powered by an alternating


current (AC) source directly provided from the mains supply.
It is not intended to be powered by AC derived from a direct
current (DC) source.
PS

2 To maintain correct power redundancy the maximum power


Note consumption of the modules installed in an SH1HU-R Shelf
should not exceed the maximum output power of the
PSU/1HU-R-AC.

The following table contains general information about the PSU/1HU-R-AC and
its environment.

Table 97: General Information


Equipment type PSU1HU-AC
First release 8.1.1
Width 200 mm (7.9”)
Height 40 mm (1.6”)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Depth (including connectors and handles) 165 mm (6.5”)


Weight 1.2 kg (2.7 lbs)
Degree of protection according to IEC IP20. Use in a pollution degree 2
60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 645,161 h
Slot positions PSU1 or PSU2 on rear side of the
SH1HU-R

The following table provides information about the power cords.

Table 98: Power Cords


Female coupler AC Appliance Coupler
according to IEC/EN 60320/C13
Power cord North America plug type: NEMA 5-15P, NEMA 6-20
wall plug rating: 125 VAC, 10 A
min. power cord rating: 18/3 SVT, 125
VAC, 10 A, VW-1, 105°C with L, N and
PE pin
Power cord Continental Europe1 plug type: CEE 7/7
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 VAC, 10 A,
H05VV-F, 105°C, 3-pole

Module and System Specification 117


PSU/1HU-R-AC

Table 98: Power Cords (Continued)


Power cord United Kingdom plug type: BS1363
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 VAC, 10 A,
H05VV-F, 105°C, 3-pole
fuse type: 2 A, 3 A, 5 A or 10 A acc. to
BS1362
Power cord International plug type: according to your local and
national electrical codes with L, N and
PE pin
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 V AC, 10 A
1. excepting Switzerland and Denmark

This table lists electrical specifications concerning the PSU/1HU-R-AC.

Table 99: Electrical Specifications


Recommended external circuit min. current rating:
breaker for full load conditions 3 A, type B or C, at 100 -127 VAC
(Each PSU/1HU-R-AC should have 3 A, type B or C, at 220 -240 VAC
its own dedicated, fused-branch
circuit.)
Input voltage 100 V to 240 V AC (+/- 10%)
50 Hz to 60 Hz

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Rated input current 1.8 A at 100 VAC
0.7 A at 240 VAC
Inrush current < 15 A, < 5 ms
Nominal power consumption 165 W
Max. power consumption under 170 W
worst case conditions
Max. output power 120 W
Nominal output voltage 12.2 V
Max. output current 10 A

The following tables provide information about fault monitoring of the module.

Table 100: Fault Monitoring Input


Alarm set interval (undervoltage) 65 V to 85 V
Alarm clear interval (undervoltage) 75 V to 89.9 V
Turn off undervoltage interval 60 VAC to 78 VAC
Turn on undervoltage interval 70 VAC to 85 VAC

Table 101: Fault Monitoring Output


Output voltage > 13.7 V; < 10.8 V
Output current > 10 A

118 Module and System Specification


Chapter 2 Shelves and Components

Table below provides information about performance monitoring of the module.

Table 102: Performance Monitoring


Output monitoring output current
Digital monitoring input voltage alarm (input voltage failure)
severe PSU failure (voltage out of range)
Temperature module temperature in °C
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 119


PSU/1HU-R-AC-200

PSU/1HU-R-AC-200
The Power Supply (PSU/1HU-R-AC-200) provides the power needed to operate
an SH1HU-R/PF shelf. Up to two power supplies can be installed into the shelf.
If two power supplies are installed load sharing and redundancy are supported.

1 The PSU/1HU-R-AC-200 has to be powered by an alternating


current (AC) source directly provided from the mains supply.
It is not intended to be powered by AC derived from a direct
current (DC) source.
PS

2 To maintain correct power redundancy the maximum power


Note consumption of the modules installed in an SH1HU-R/PF
should not exceed the maximum output power of the
PSU/1HU-R-AC-200.

The following table contains general information about the PSU/1HU-R-AC-200


and its environment.

Table 103: General Information


Equipment type PSU1HU-AC
First release 10.3
Width 200 mm (7.9”)
Height 40 mm (1.6”)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Depth (including connectors and handles) 165 mm (6.5”)
Weight 1.2 kg (2.8 lbs)
Degree of protection according to IEC IP20. Use in a pollution degree 2
60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 634,456 h
Slot positions PSU1 and/or PSU2 slot on rear
side of the SH1HU-R/PF

The following table provides information about the power cords.

Table 104: Power Cords


Female AC Appliance Coupler
coupler according to IEC/EN 60320/C13
Power cord plug type: NEMA 5-15P, NEMA 6-20
North wall plug rating: 125 V AC, 10 A
America min. power cord rating: 18/3 SVT, 125 V AC, 10 A, VW-1,
105°C with L, N and PE pin
Power cord plug type: CEE 7/7
Continental wall plug rating: 250 V AC, 10 A
Europe1 min. power cord rating: 250 V AC, 10 A, H05VV-F, 105°C,
3-pole

120 Module and System Specification


Chapter 2 Shelves and Components

Table 104: Power Cords (Continued)


Power cord plug type: BS1363
United wall plug rating: 250 V AC, 10 A
Kingdom min. power cord rating: 250 VAC, 10 A, H05VV-F, 105°C,
3-pole
fuse type: 2 A, 3 A, 5 A or 10 A acc. to BS1362
Power cord plug type: according to your local and national electrical
International codes with L, N and PE pin
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 V AC, 10 A
1. excepting Switzerland and Denmark

This table lists electrical specifications concerning the PSU/1HU-R-AC-200.

Table 105: Electrical Specifications


Recommended external circuit min. current rating:
breaker for full load conditions 3 A, type B or C, at 100 - 127 V AC
(Each PSU/1HU-R-AC-200 should 2 A, type B or C, at 220 - 240 V AC
have its own dedicated, fused-branch
circuit.)
Input voltage 100 V to 240 V AC (+/- 10%)
50 Hz to 60 Hz
Rated input current 2.5 A at 100 V AC
1.1 A at 240 V AC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Inrush current < 15 A, < 5 ms


Nominal efficiency > 80%
Nominal power consumption 240 W
Max. power consumption under worst 250 W
case conditions
Max. output power 200 W
Nominal output voltage 12.2 V
Max. output current 16.4 A
Output over current protection point > 17.4 A

The following tables provide information about fault monitoring of the module.

Table 106: Fault Monitoring Input


Alarm set interval (undervoltage) 65 V to 85 V
Alarm clear interval (undervoltage) 75 V to 89.9 V
Turn off undervoltage interval 60 VAC to 78 VAC
Turn on undervoltage interval 70 VAC to 85 VAC

Table 107: Fault Monitoring Output


Output voltage > 13.7 V; < 10.8 V
Output current > 16.4 A

Module and System Specification 121


PSU/1HU-R-AC-200

Table below provides information about performance monitoring of the module.

Table 108: Performance Monitoring


Output monitoring output current
Digital monitoring input voltage alarm (input voltage failure)
severe PSU failure (voltage out of range)
Temperature module temperature in °C

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

122 Module and System Specification


Chapter 2 Shelves and Components

PSU/1HU-R-DC-200
The PSU/1HU-R-DC-200 is a plug-in 200-W DC-input power supply unit specifi-
cally designed for the SH1HU-R/PF shelf. Up to two power supplies can be
installed into the shelf. If two power supplies are installed load sharing and
redundancy are supported. Permanent mixed operation is supported with the
PSU/1HU-R-AC-200 per shelf.

Pay attention that for permanent power redundancy the total


maximum power consumption of the modules installed in an
PS

SH1HU-R/PF shelf does not exceed the maximum output power of


Note the PSU/1HU-R-DC-200.

The PSU/1HU-R-DC-200 is forced-air cooled.

Table 109: General Specifications


Equipment type PSU1HU-DC
First release 12.1
Width 200 mm (7.9”)
Height 40 mm (1.6”)
Depth (including connectors and 175 mm (6.9”)
handles)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Weight 1.2 kg ( 2.8 lbs)


Cooling one integrated fan, temperature
controlled
Air dust filter replaceable air filter pad, accessible
on the front panel
Air filter pad replacement intervals every 90 days
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IEC IP20. Use in a pollution degree 2
60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 285,687 h
Slot positions PSU1 and/or PSU2 slots on rear side
of the SH1HU-R/PF

Module and System Specification 123


PSU/1HU-R-DC-200

Table 110: Power Cables For Connedting the PSU/1HU-R-DC-200


Order Number DC Cable Variants
Cable Length of 3 meters (10 ft.)
1036700026 CABLE PWR DC 3XAWG14 PHX 3M00 B+ R
1036700027 CABLE PWR DC 3XAWG14 PHX 3M00 BK BL
1036700028 CABLE PWR DC 3XAWG14 PHX 3M00 BL GR
Cable Length of 10 meters (32.8 ft.)
1036700029 CABLE PWR DC 3XAWG14 PHX 10M00 B+ R
1036700030 CABLE PWR DC 3XAWG14 PHX 10M00 BK BL
1036700031 CABLE PWR DC 3XAWG14 PHX 10M00 BL GR

Table 111: Electrical Specifications


Recommended external circuit min. 7 A hydraulic magnetic circuit
breaker requirement for full load breaker, characteristic curve C, D
conditions according to IEC/EN 60898 or similar or
10 A thermic circuit breaker
Power cord AWG 14 AWM-Style 1015 (105°C) with
jacketed cord, min. FT1 or VW1,
standard length 3.05 m (10 ft.); 10 m
(32.8 ft.) on request); female Phoenix
connector; Use of the cables provided

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
by ADVA Optical Networking is
mandatory. See Table 110.
Input
DC Input connector male 3-pin Dinkle power connector
(Plus, Minus, PE) on the front panel
Rated input voltage -48 V DC
Input voltage range -36 V to 72 V DC
Rated input current range < 6.25 A to 3.2 A
Maximum input current < 6.6 A at 36 V, full load
Inrush current (0.1 ms after power < 10 A at 72 V, cool and warm status
on)
Power
Typical power consumption 215 W
Max. power consumption under 220 W
worst case conditions
Standby power consumption 5W
Output
Nominal output voltage 12.2 V (+/- 0.2 % initial set point)
Minimum output current 0A
Max. output current 16.4 A (voltage can drop to 11.9 V at
full load
Max. output power 200 W
Minimum hold-up time 10 ms

124 Module and System Specification


Chapter 2 Shelves and Components

Table 112: Typical Efficiency


Load -48 V DC
100% load 93.0%
50% load 93.5%
20% load 90.0%

The efficiency values meet the requirements of the 80PLUS® Energy Star
class: “Platinum”.

Table 113: Fault Consecutive Actions


Reverse Input polarity long endurance protected
Turn off undervoltage interval -32 VDC to -34 VDC
Turn on undervoltage interval -34 VDC to -36 VDC
Turn off overvoltage intervall -77 VDC to -79 VDC
Turn on overvoltage intervall -75 VDC to -77 VDC
Alarm set interval (undervoltage) -32 VDC to -35 VDC
Alarm clear interval (undervoltage) -34 VDC to -37 VDC
Overtemperature alarm set point 90 °C module temperature
Overtemperature turn off set point 110 °C module temperature
Recover from Overtemperature turn off 100 °C module temperature
set point
Output overvoltage turn off intervall > 14.1 V; < 15.3 V (latching)
Output overcurrent intervall 18.0 A to 19.7 A
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Output overcurrent alarm set point 16.4 A


Output short circuit Hiccup mode

Table 114: Performance Monitoring


Input monitoring Input voltage
Input current
Output monitoring Output current
Temperature module temperature in °C

Table 115: Fault Monitoring


Voltage input voltage alarm (input voltage failure)
severe PSU failure (voltage out of range)
Current output overcurrent alarm
Temperature overtemperature alarm

Module and System Specification 125


FAN/1HU

FAN/1HU
The FAN/1HU is a plug-in fan module specifically designed for the SH1HU-R/PF
shelf. The module consists of three high-power fans to generate sufficient air
flow for module cooling. Each fan is supplied separately and operates
independently of one another. The fans are powered using a common
backplane connector.
The FAN/1HU module can only be installed in the left most slot of the
SH1HU-R/PF shelf. This slot is covered by the display panel during normal
operation. The fan module has a single tri-color LED labeled "Fan" on the front
panel of the SH1HU-R/PF shelf to indicate the different operating states of the
three fans.
Table below contains general information about the FAN/1HU and its
environment.

Table 116: General Information


Equipment type FAN1HU
First release 10.3
Dimensions for use in the SH1HU-R/PF
Weight 166 g (0.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
IEC 60529 environment and indoor controlled
office environments only.
Typ. power consumption 1.5 W (25°C ambient temperature)
Max. power consumption 20.0 W
MTBF at 25°C ambient temperature 4,687,387 h
Slot position The fan unit is placed in the left most
slot and is covered by the display
panel. When the display panel is
removed the fans stop automatically
and the fan unit can be accessed
safely.
Mean time to replace < 1 min

This table provides information about the fan data.


Table 117: Fan Data
Number of fans 3
Fan rotation speed 4000...19000 rpm temperature controlled

The failure of a single fan does not affect the cooling of the
modules in the shelf up to an ambient temperature of 45°C within 
PS

48 hours. The whole plug-in fan unit should be replaced by ADVA


Optical Networking approved Service Personnel within 48 hours
Note
after a single fan failure.

126 Module and System Specification


Chapter 2 Shelves and Components

SH1HU/PASSIVE/FT
The SH1HU/PASSIVE/FT is a standalone, non-managed shelf with a fiber tray.
It is intended to carry passive modules, such as filters, splitters and dispersion
compensation modules. It can hold up to
• four modules with a width of 4 HP or
• two modules with a width of 4 HP and one module with a width of 8 HP or
• two modules with a width of 8 HP
The following table shows general information about the shelf and its
environment.

Table 118: General Information


Equipment type SH1HU-P
First release 8.3
Width (dimension without adaptor 446 mm (17.6’’)
brackets),
Height 71.5 mm (2.82’’)
Depth (dimension without adaptor 270.5 mm (10.65’’)
brackets)
Slots for passive modules 4
Weight empty 2.9 kg (6.4 lbs)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Environmental conditions Telcordia SR-3580 level 3 (NEBS),


ETSI EN 300 019-1-3 Class 3.1
Extended temperature range -25°C to +70°C
only if passive filter modules are used
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient n.a.
temperature
Power consumption n.a.

Module and System Specification 127


FMT/1HU

FMT/1HU
The FMT/1HU is a rack-mountable, 1HU-high fiber management shelf. It
includes a fiber optic tray to efficiently manage the optical fibers used within an
FSP 3000R7 system deployment. The fiber management shelf is used to
orderly maintain the fiber storage of an SH1HU, SH7HU or SH9HU shelf. Two
screws on the front side of the shelf allow access to the fiber optic tray.
The following table shows general information about the shelf and its
environment.

Table 119: General Information


First release 9.2
Width (dimension without adaptor 443 mm (17.441’’)
brackets)
Height 43.4 mm (1.709’’)
Depth (dimensions without adaptor 273 mm (10.748’’)
brackets)
Cable capacity for 26 cables, lengths 45 to 145 cm
3 mm diameter cable 15 cables, lengths 146 to 240 cm
11 cables, lengths 241 to 340 cm
Cable capacity for 60 cables, lengths 45 to 145 cm
2 mm diameter cable 35 cables, lengths 146 to 240 cm
25 cables, lengths 241 to 340 cm

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Cable capacity for 83 cables, lengths 45 to 145 cm
1,7 mm diameter cable 48 cables, lengths 146 to 240 cm
35 cables, lengths 241 to 340 cm
Weight empty 4.7 kg (10.3 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient n.a.
temperature
Power consumption n.a.

128 Module and System Specification


Chapter 2 Shelves and Components

OTDR
The optical time reflectometer (OTDR) is a rack-mounted unit that combines a
test head controller (OTDR/THC/2HU/AC) unit and optical test head
(OTDR/8-OTH/1HU/AC) unit.
Placed at an installation site, the OTDR directly controls the measurements.
The OTDR/THC/2HU/AC unit has an Ethernet port for local access on the front
panel and ports on the rear panel for connecting to the OTH unit, LAN,
telephone line, and to an optional external optical switch.
The OTDR has an integrated Web application for managing fiber monitoring and
can store the data on a RAID protected hard disk.
For integration into the FSP 3000R7 system the OTDR/THC/2HU/AC has to be
connected via Ethernet LAN to NCU1.

The OTDR must not be deployed in RAMAN-C10 and


PS

2RAMAN-C15-LL configurations.
Note

Table 120 provides general information about the shelf and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 120: General Information


Equipment type
OTDR/8-OTH/1HU/AC OTDR8OTH1HU-AC
OTDR/THC/2HU/AC OTDRTHC2HU-AC
First release 9.3
OTDR/8-OTH/1HU/AC dimensions
Width (dimension without adaptor 426 mm (16.772”)
brackets)
Height 44 mm (1.732”)
Total depth (dimension without 309 mm (12.165”)
adaptor brackets, but with power
supplies)
OTDR/THC/2HU/AC dimensions
Width (dimension without adaptor 426 mm (16.772”)
brackets)
Height 88.5 mm (3.484”)
Total depth (dimension without 318 mm (12.52”)
adaptor brackets, but with power
supplies)

1. An NCU with a CF of 512 MB requires a separate procedure for an OTDR


software upgrade. Contact Technical Services for details.

Module and System Specification 129


OTDR

Table 120: General Information (Continued)


Total OTDR dimensions
Width (dimension without adaptor 426 mm (16.8”)
brackets)
Height 132.5 mm (5.2”)
Total depth (dimension without 318 mm (12.9”)
adaptor brackets, but with power
supplies)
Total weight (all slots unpopulated) 13.45 kg (29.7 lbs)
Weight OTH 5.3 kg (11.7 lbs)
Weight THC 8.15 kg (17.9 lbs)
Environmental conditions ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 35,047 h
Storage Capacity (HDDs) 80 GB in RAID
Fans
OTDR/8-OTH/1HU/AC 1 built-in non-replaceable fan
OTDR/THC/2HU/AC 2 built-in redundant fans

This table lists electrical specifications concerning the OTDR.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 121: Electrical Specifications
Input connector AC Appliance Coupler
according to IEC/EN 60320
Power cord North America plug type: NEMA 5-15P, NEMA 6-20
wall plug rating: 125 VAC, 10 A
min. power cord rating: 18/3 SVT, 125
VAC, 10 A, VW-1, 105°C with L, N and
PE pin
Power cord Continental Europe plug type: CEE 7/7, CEE 7/4
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 VAC, 10 A,
HO5W-F, 105°C, 3-pole
Power cord United Kingdom plug type: BS1363
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 VAC, 10 A,
H05VV-F, 105°C, 3-pole
fuse type: 3 A, 5 A or 10 A
Power cord International plug type: according to your local and
national electrical codes with L, N and 
PE pin
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 V AC, 10 A
Input voltage 100 V to 240 V AC (+/- 10%)
50 Hz to 60 Hz
Recommended external circuit min. current rating 3 A
breaker for full load conditions

130 Module and System Specification


Chapter 2 Shelves and Components

Table 121: Electrical Specifications (Continued)


Max. power consumption
OTDR/8-OTH/1HU/AC 17 W
OTDR/THC/2HU/AC 91 W
Total OTDR 107.8 W
Steady state power consumption
OTDR/8-OTH/1HU/AC 18 W
OTDR/THC/2HU/AC 74 W
Total OTDR 92 W

Table below contains information about the available indicators of the unit.

Table 122: Indicators


THC unit LEDs to visualize status of THC unit
OTH unit LEDs to visualize status of OTH unit
OTDR laser LED to visualize status of OTDR laser
EMS LED to visualize status of EMS
communication

Following table contains information about the optical connector and fiber type.

Table 123: Optical Interfaces


Number of OTDR ports 8
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Number of ethernet interface 1


Optical connector type of OTDR FC/APC 8 degrees angled connector
ports for 1650nm OTDR monitoring
Optical connector type Ethernet port RJ-45 management port at the rear
Fiber type SM G.652

Table below contains information about the ethernet interface and cable type.

Table 124: Ethernet Interface


Electrical connector type RJ45
Cable category CAT5E
Cable type unshielded for cable length: < 3 m
shielded (S/FTP) for cable length: 3 m to 100 m
Performance 10/100 Mbit/s Fast Ethernet half/full duplex

This table shows information about the optical specifications.

Table 125: Optical Specifications


Min. working wavelength 1644.5 nm
Typ. working wavelength 1650 nm
Max. working wavelength 1657.5 nm
Dynamic range at normal resolution min: 17.3 dB; typ: 19.9 dB
for average time = 30 s, measurement
range = 80 km, pulse width = 100 ns1

Module and System Specification 131


OTDR

Table 125: Optical Specifications (Continued)


Dynamic range at normal resolution min: 24.3 dB; typ: 26.5 dB
for average time = 30 s, measurement
range = 160 km, pulse width = 1 µs1
Dynamic range at normal resolution min: 34.4 dB; typ: 38.2 dB
for average time = 30 s, measurement
range = 160 km pulse width = 10 µs1
Dynamic range at normal resolution min: 34.5 dB; typ: 39.5 dB
average time = 30 s, measurement
range = 160 km, pulse width = 20 µs1
Dynamic range at high resolution for min: 18 dB; typ: 20.7 dB
average time = 60 s, measurement
range = 80 km, pulse width = 100 ns1
Dynamic range at high resolution for min: 25.2 dB; typ: 27.4 dB
average time = 60 s, measurement
range = 160 km, pulse width = 1 µs1
Dynamic range at high resolution for min: 34.6 dB; typ: 38.8 dB
average time = 60 s, measurement
range = 160 km, pulse width = 10 µs1
Dynamic range at high resolution for min: 35 dB; typ: 40.2 dB
average time = 60 s, measurement
range = 160 km, pulse width = 20 µs1

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Event dead zone typ: 0.8 m; max: 1 m
Attenuation dead zone typ: 4.5 m; max: 5.5 m
Linearity +/- 0.03
1. at Signal to noise ratio = 1

132 Module and System Specification


Chapter 3

Core Type Channel Modules


This chapter describes core type channel modules of the FSP 3000R7.
The descriptions of the discontinued core type channel modules can be found in
a former version of the FSP 3000R7 Module and System Specification.
The following sections are provided:
“WCC-PCTN-100GB” on p. 134
“WCC-PCTN-100GA” on p. 143
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

“10TCC-PCTN-10G+100GB” on p. 149
“WCC-PCTN-10G” on p. 159
“4TCC-PCTN-2G7+10G” on p. 170
“10TCC-PCTN-4GUS+10G” on p. 180
“10TCC-PCN-2G7US+10G” on p. 192
“10WXC-PCN-10G” on p. 202
“2WCC-PCN-10G” on p. 209
“2TWCC-PCN-2G7U” on p. 218
“WCC-PC1N-2G7U” on p. 227

Module and System Specification 133


WCC-PCTN-100GB

WCC-PCTN-100GB
The WCC-PCTN-100GB core transponder provides transparent transport of
100GbE or OTU4 client side service in a four-slot module. The OTU4 client
interface enables Reed-Solomon (RS) FEC (GFEC) according to ITU-T G.709.
The WCC-PCTN-100GB transponder supports a limited set of physical level
fault reporting and performance monitoring of the OTU4 client interface.
Enhanced FEC (EFEC-6) at the network port enables ultra long reach perfor-
mance.
The WCC-PCTN-100GB transponder module contains a single network side
interface with an internal Dual Polarization Quadrature Phase Shift Keying
(DP-QPSK) transponder module and a single client side interface with a CFP
MSA standard compliant pluggable transceiver.
The client signal is internally mapped according to G.709 resulting in an OTU4V
signal for transport over a core optical transport network. The DWDM network
side optics with DP-QPSK modulation is tunable within the 50 GHz channel grid.
Input wavelength selection is supported by a coherent receiver.
The client side CFP performs the optical-to-electrical and electrical-to-optical
conversion function as well as collection of physical Layer PMs and Fault moni-
toring. The optical performance of the client interface is specified by the
equipped CFP module. See the selected CFP module specification for addi-
tional information.
The WCC-PCTN-100GB provides performance monitoring data at the client port

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
as well as at the network port for the physical layer, service layer, and FEC. Per-
formance monitoring data is also provided at the PCS layer for 100 GbE client
interface service.
The module supports Client Channel Card Protection (CCCP) for LR4 and LR10
CFP transceivers. CCCP for SR10 CFP transceivers is not supported.
Table 126 provides general information about the module and its environment.

Table 126: General Information


Equipment type WCC100GB
First release 12.1
Width 16 HP
Height 5 HU
Weight 2540 g (5.6 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 197,598 h
Typ. power consumption 145 W
(incl. pluggable transceivers)
Max. power consumption 160 W
(incl. pluggable transceivers)

134 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 126: General Information (Continued)


Slot positions Only the SH9HU, slots: 3...15
NCU types NCU-II, NCU-II-P

Table 127 provides information about the client port.

Table 127: Client Port - Specifications


Number of client ports 1
Data rates 103.1 Gbit/s, 111.8 Gbit/s
Protocols 100 GbE, OTU4
Type of client port Pluggable CFP
Optical connector type Depends on plug type. (LC or MPO)
Fiber type 9 µm (Depends on plug type)

Table 128 provides information about jitter and wander compliance.

Table 128: Jitter and Wander Compliance


Jitter and wander GbE according to IEEE802.3 and G.8262 for
compliance for transparent transport of SyncE
GbE compliant for transparent transport of
1588v2 PTP frequency synchronization acc to
G.8265
STM-n according to G.783 and G.813
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 129 provides information about the recommended maximum client port
pre-FEC bit error ratio for (GFEC).

Table 129: Recommended Maximum Client Port Pre-FEC BER


GFEC 1 x 10-5

Table 130 provides information about the CFPs supported by the client ports.
Please refer to the Pluggable Transceiver Specifications in Chapter 6 of this
manual for individual CFP specifications.

Table 130: Supported Client CFP Types


LR4 type CFP/112G/LR4/SM/LC
LR10 type CFP/112G/LR10R/SM/LC
SR10 type CFP/103G/SR10/MM/MPO

Table 131 provides information about the network port.

Table 131: Network Port - Specifications


Number of network ports 1
Optical connector type LC
Fiber type SM 9 µm
Type of network port Tunable DWDM interface

Module and System Specification 135


WCC-PCTN-100GB

Table 131: Network Port - Specifications (Continued)


Data rate 120.579 Gbit/s (includes 15%
overhead due to SD-FEC)
Protocol OTU4V
Modulation Format DP-QPSK with coherent detection
Transmitter output power range -5.0 dBm ... +1.0 dBm
OPT accuracy +/-1.0 dB
OPT measurement range -6.0 dBm to +2.0 dBm
Transmitter wavelength range Supports 96 C-band wavelengths on
50 GHz spacing with a tunable
interface from 1529.55 to 1567.54nm.
Wavelength stability (operating) +/- 60 pm
Max. cold startup time of controller 3 min
Max. cold startup time with new <15 min
optical link
Max. cold startup time with 3 min
unchanged optical link
Min. side mode suppression ratio 40 dB
Receiver wavelength range 1529.55 nm to 1567.52 nm
Receiver dynamic range -18 dBm to -2 dBm
OPR measurement range -18.0 dBm to -2.0 dBm
OPR accuracy +/-0.5 dB

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
PMD tolerance 30 ps max.
CD tolerance -6,000 ps/nm to +60,000 ps/nm

Table 132 provides information about the bit error rate versus OSNR.
Table 132: Bit Error Rate Versus OSNR
Pre FEC bit error ratio for 1.9 x 10-2 at 13.8 dB OSNR at 0.1 nm EOL
EFEC-61 with Post FEC bit
error ratio of 10-12
1. Soft-decision FEC providing 11.2 dB net coding gain

To achieve a post-FEC BER better than 10-12, ADVA Optical


Networking recommends operating the network port of the
PS

module at pre-FEC BER values not higher than stated in the


Note following table.

Table 133 provides information about the recommended maximum network port
pre-FEC bit error ratio for (EFEC-6).

Table 133: Recommended Maximum Network Port Pre-FEC BER


EFEC-6 1.9 x 10-2

136 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 134 provides information about the system performance.

Table 134: System Performance


Max. module delay 16.3 µs for 100 GbE at the client side
22 µs for OTU4 at the client side
Max. Ethernet Frame Size 9224 bytes

0
Whether fault/performance monitoring entries listed in the
PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

Table 135 provides information about fault monitoring of the module in general.

Table 135: Fault Monitoring - General


Equipment Alarm Name TL-1 Keyword
Equipment Equipment Removed RMVD
Equipment Mismatch MEA__CONDITION
Voltage Out of Range VOLTANR
Equipment Fault HWFLT
FWP-Mismatch (NSA) FWPM-NSA
FWP-Mismatch (SA) FWPM-SA
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 136 provides information about fault monitoring of the client port in
general.

Table 136: Fault Monitoring Client Interface - General


Layer Alarm Name TL-1 Keyword
Physical Laser Failure LASER
layer Laser-Current
Abnormal LBCLANR
Rx Clock-Loss of Sync RCVCLK
Loss of Signal LOS

Table 137 provides information about fault monitoring of the client port in
ingress direction.

Table 137: Fault Monitoring Client Interface - Ingress Direction


Layer Alarm Name TL-1 Keyword
100 GbE Loss of Lane Alignment LOL
Bit Error Rate High HIBER
Local Fault LOCAL-FLT
Loss of Char Sync CHARSYNC

Module and System Specification 137


WCC-PCTN-100GB

Table 137: Fault Monitoring Client Interface - Ingress Direction (Continued)


OCH/ OTU OTU-Loss of Frame LOF-OTU
layer OTU-Loss of multiframe LOM-OTU
OTU-Loss of Lane
Alignment LOL-OTU
OTU-Signal Degrade SD-OTU
ODU-PM byte ODU-AIS AIS-ODU
ODU-Lock LCK-ODU
ODU-Signal Degrade SD-ODU

Table 138 provides information about fault monitoring of the network ports in
general.

Table 138: Fault Monitoring Network Interface - General


Layer Alarm Name TL-1 Keyword
Physical layer Laser Failure LASER
Rx Clock-Loss of Sync RCVCLK
Loss of Signal LOS
Laser-Current Abnormal LBCLANR
Rx Laser-Abnormal LOCLANR

Table 139 provides information about fault monitoring of the network ports in
egress direction.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 139: Fault Monitoring Network Interface - Egress Direction
Layer Alarm Name TL-1 Keyword
OTU4 layer OTU-Loss of Frame LOF-OTU
OTU-Loss of multiframe LOM-OTU
OTU-Loss of Lane LOL-OTU
Alignment
OTU4 layer - SM byte OTU-BDI BDI-OTU
OTU-Signal Degrade SD-OTU
OTU-TIM TIM-OTU
ODU4 layer - PM byte ODU-AIS AIS-ODU
ODU-BDI BDI-ODU
ODU-Open Connection OCI-ODU
ODU-Lock LCK-ODU
ODU-Signal Degrade SD-ODU
ODU-TIM ODU-TIM

138 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 139: Fault Monitoring Network Interface - Egress Direction


OPU4 layer AIS AIS
Payload Mismatch PLM
Client Signal Fail CSF
TCMx layer TCM_x-AIS AIS-TCMx
TCM_x-BDI BDI-TCMx
TCM_x-Open
Connection OCI-TCMx
TCM_x-Lock LCK-TCMx
TCM_x-Signal Degrade SD-TCMx
TCM_x-TIM TIM-TCMx
TCM_x-Connection
Loss LTC-TCMx

Table 140 provides information about performance monitoring of the module in


general.
Table 140: Performance Monitoring - General
Layer Alarm Name TL-1 Keyword
Equipment Module temperature TEMP
(Fix threshold crossing (current value)
alert for module
temperature too high
available)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 141 provides information about performance monitoring of the client ports
in ingress direction.

Table 141: Performance Monitoring Client Interface - Ingress Direction


Layer Alarm Name TL-1 Keyword
Physical layer OPR; OPT (+/- OPR
(15 min/24 h records available for 0.5dB accuracy)
PM values except current values;
Fixed threshold crossing alerts
and too high/too low available)
Physical layer (current values) Laser Bias Current LBCL
Physical layer Laser LSRTEMP
(current values; Fixed threshold Temperature
crossing alerts and too high/too
low available)
Ethernet PCS Layer  PCS Errored
(15 min/24 h records with user Seconds ES-PCS
configurable threshold crossing PCS Code
alerts available) Violations CV-PCS
Ethernet MAC Layer (current Frames Rx FRRCV
value only) Pause Frames Rx PSFRRCV
CRC Errors Rx1 CRCFRRCV
BYTES Rx BYTERCV

Module and System Specification 139


WCC-PCTN-100GB

Table 142 provides information about performance monitoring of the client ports
in egress direction.

Table 142: Performance Monitoring Client Interface - Egress Direction


Layer Alarm Name TL-1 Keyword
Ethernet Mac Layer (current Frames Tx FRTRMT
value only) Pause Frames Tx PSFRTRMT
Egress CRC
Errors1 CRCFREGRS
BYTES Tx BYTETRMT

1. Received Ethernet frames are transparently transported. The Ethernet frame


monitor operates in parallel to the transport stream and performs a Cyclic
Redundancy Check (CRC) using the IEEE defined CRC-32 polynomial
according to IEEE 802.3 clause 3.2.9 (FCS). Sending equipment using an
alternate CRC-32 polynomial for extended frame sizes will cause the
Ethernet Frame Monitor on the WCC100GB to accumulate a CRC error for
those frames.
Table 143 provides information about performance monitoring of the network
ports in general.

Table 143: Performance Monitoring Network Interface - General


Layer Alarm Name TL-1 Keyword
Physical layer OPR (+/- 0.5dB OPR

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
(15 min/24 h records available accuracy)
for PM values except current CD Compensation CD
values; Diff Group Delay DGD
Fixed threshold crossing alerts SNR SNR
and too high available except OPT (+/- 0.5dB
SNR; accuracy) OPT
Fixed threshold crossing alerts Carrier Frequency
and too low available on OPR, Offset CFOT
CD Compensation, SNR, Carrier RX Laser Bias
Frequency Offset, OPT and Rx Current LOCL
Laser Temperature) Rx Laser
Temperature LOTEMP
Physical layer (current values) Laser Bias Current LBCL
Physical layer Laser Temperature LSRTEMP
(current values; Fixed threshold
crossing alerts and too high/too
low available)

140 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 144 provides information about performance monitoring of the network


ports in egress direction.

Table 144: Performance Monitoring Network Interface - Egress Direction


Layer Alarm Name TL-1 Keyword
OTU4 FEC layer FEC-Corrected
(15 min/24 h records with Errors CE-FEC
user configurable threshold FEC-UBE UBE-FEC
crossing alerts available, FEC-BERCE BERCE-FEC
except BERCE)
OTU4 layer - SM byte OTU-Errored
(15 min/24 h records with Seconds ES-OTU
user configurable threshold OTU-SES SES-OTU
crossing alerts available) OTU-UAS UAS-OTU
OTU-BBE BBE-OTU
ODU4 layer - PM byte ODU-Errored
(15 min/24 h records with Seconds ES-ODU
user configurable threshold ODU-SES SES-ODU
crossing alerts available) ODU-UAS UAS-ODU
ODU-BBE BBE-ODU

TCMX layer TCM_x-Errored


(15 min/24 h records with Seconds ES-TCMx
user configurable threshold TCM_x-SES SES-TCMx
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

crossing alerts available) TCM_x-UAS UAS-TCMx


TCM_x-BBE BBE-TCMx

OPU layer Elapsed Time ET


Error Free ERRFREE
Average Bit Error
Rate AVGBER
Max Measured BER MAXBER

Table 145 provides information about the loop functionality.

Table 145: Loop Functionality


Client port Terminal and facility loop
Network ports Terminal and facility loop

Table 146 provides information about protection switching.

Table 146: Protection Switching


Protection scheme Client Channel card protection
Protection switching time < 150 ms
Signal fail switching criteria physical LOS
Restoration scheme Versatile switched protection
(RSM-OLM, VSM)
Service restoration time TBD

Module and System Specification 141


WCC-PCTN-100GB

Table 147 provides information about the link test functionality. This test
function is available on the network port only.

Table 147: Link Test PRBS Functionality


Initiate Transmit Test Enable/Release status
Initiate Receive Test Enable/Release status
Reset test
Test elapsed time
Error free elapsed time
Average BER during Test
Maximum BER during Test

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

142 Module and System Specification


Chapter 3 Core Type Channel Modules

WCC-PCTN-100GA
The WCC-PCTN-100GA core transponder provides transparent transport of 
100 GbE or OTU4 client side service in a five-slot module. The OTU4 client
interface enables Reed-Solomon (RS) FEC (GFEC) according to ITU-T G.709.
The WCC-PCTN-100GA transponder supports physical level fault reporting and
performance monitoring of the OTU4 client interface. Enhanced FEC (EFEC-4)
at the network port enables ultra long reach performance.
The WCC-PCTN-100GA transponder module contains a single network side
interface with an internal Dual Polarization Quadrature Phase Shift Keying
(DP-QPSK) transponder module and a single client side interface with a CFP
MSA standard compliant pluggable transceiver.
The client signal is internally mapped according to G.709 resulting in an OTU4V
signal for transport over a core optical transport network.The DWDM network
side optics with DP-QPSK modulation is tunable within the 50 GHz channel grid.
Input wavelength selection is supported by a coherent receiver.
The client side CFP performs the optical-to-electrical and electrical-to-optical
conversion function as well as collection of physical Layer PMs and Fault
monitoring. The optical performance of the client interface is specified by the
equipped CFP module. See the selected CFP module specification for
additional information.
The WCC-PCTN-100GA provides performance monitoring data at the client port
as well as at the network port for the physical layer, service layer and FEC.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Performance monitoring data is also provided at the PCS layer for 100 GbE
client interface service.
Table 148 contains general information about the module and its environment.

Table 148: General Information


Equipment type WCC100GT-D
First release 11.1
Width 20 HP
Height 5 HU
Weight 3.3 kg (7.2 lbs)
Environmental conditions 0 ... 40 °C,
10% ... 90% humidity non condensing
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 270,489 h
Typ. power consumption 200 W for HW rev. 1.01
(incl. pluggable transceivers) 160 W for HW rev. 1.02
Max. power consumption 230 W for HW rev. 1.01
(incl. pluggable transceivers) 175 W for HW rev. 1.02
Slot positions Only the SH9HU, slots: 3...14
NCU types NCU-II, NCU-II-P

Module and System Specification 143


WCC-PCTN-100GA

The following table provides information about the client port.

Table 149: Client Port


Number of client ports 1
Data rates 103.1 Gbit/s, 111.8 Gbit/s
Protocols 100 GbE, OTU41
Type of client port Pluggable CFP
Optical connector type LC
Fiber type 9 µm
1. OTU4 client interface supports physical layer fault reporting and
performance monitoring only.

In the following the CFPs supported by the client ports. Please refer to the
specifications for the individual CFP type.
• CFP/112G/LR4/SM/LC
• CFP/112G/LR10R/SM/LC

The following table contains information about the network port.

Table 150: Network Port


Number of network ports 1

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type LC
Fiber type SM 9 µm
Type of network port Tunable DWDM interface
Data rates 120.579 Gbit/s
Protocols OTU4V
Transmitter output power range -5 dBm ... +1 dBm
Transmitter wavelength range Supports 96 C-band wavelengths on
50 GHz spacing with a tunable
interface from 1529.55 to 1567.54nm.
Wavelength stability (operating) +/- 60 pm
Max. cold startup time of controller 3 min
Max. cold startup time with new <15 min
optical link
Max. cold startup time with 3 min
unchanged optical link
Min. side mode suppression ratio 40 dB
Receiver wavelength range 1529.55 nm to 1567.52 nm
Receiver dynamic range -18 dBm to -2 dBm
Max input power 10 dBm
PMD tolerance 30 ps max.
CD tolerance -50,000 ps/nm to +50,000 ps/nm

144 Module and System Specification


Chapter 3 Core Type Channel Modules

This table provides information about the bit error rate versus OSNR.
Table 151: Bit Error Rate Versus OSNR
Pre FEC bit error ratio for 1.9 x 10-2 at 14.5 dB OSNR at 0.1 nm EOL
EFEC-41 with Post FEC bit
error ratio of 10-12
1. soft-decision FEC providing 11.2 dB net coding gain

To achieve a post-FEC BER better than 10-12, ADVA Optical


Networking recommends operating the network port of the
PS

module at pre-FEC BER values not higher than stated in the


Note following table.

This table shows the recommended maximum pre-FEC bit error ratio for client
port (GFEC) and network port (EFEC-4).

Table 152: Recommended Maximum Pre-FEC BER


GFEC 1 x 10-5
EFEC-4 1.9 x 10-2

This table contains information about the system performance.

Table 153: System Performance


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Max. module delay 16.3 µs for 100 GbE at the client side
22 µs for OTU4 at the client side

0
Whether fault/performance monitoring entries listed in the
PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

This table shows information about fault monitoring of the module in general.

Table 154: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Capability Level mismatch

Module and System Specification 145


WCC-PCTN-100GA

This table shows information about fault monitoring of the client port in general.

Table 155: Fault Monitoring Client Interface - General


Physical layer Laser failure;
Laser degrade (based on bias current);
Receiver clock synch failure;
Loss of signal (LOS)

This table shows information about fault monitoring of the client port in ingress
direction.

Table 156: Fault Monitoring Client Interface - Ingress Direction


100 GbE LOL; HIBER; LOCAL FAULT; CHAR SYNC
OCH/ OTU layer LOF; LOM; AIS; LOL
ODU-PM byte AIS; LCK

This table shows information about fault monitoring of the network ports in
general.

Table 157: Fault Monitoring Network Interface - General


Physical layer Laser failure;
Receiver clock synch failure;
Loss of signal (LOS)
Laser degrade (Laser Bias Current)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Local Oscillator degrade (Loc Osc
Bias Curr Lvl (LO Bias))

This table provides information about fault monitoring of the network ports in
egress direction.

Table 158: Fault Monitoring Network Interface - Egress Direction


OTU4 layer LOF; LOM; AIS; LOL
OTU4 layer - SM byte BDI; SD; TIM
ODU4 layer - PM byte AIS; BDI; OCI; LCK; SD
OPU4 layer AIS; PLM; CSF
TCMX layer AIS; BDI; OCI; LCK; SD; TIM; LTC

The following table provides information about performance monitoring of the


module in general.
Table 159: Performance Monitoring - General
Equipment Module temperature (current value)
(Fix threshold crossing alert for
module temperature too high
available)

146 Module and System Specification


Chapter 3 Core Type Channel Modules

The following table gives information about performance monitoring of the client
ports in ingress direction.

Table 160: Performance Monitoring Client Interface - Ingress Direction


Physical layer OPR; OPT
(15 min/24 h records available for PM values
except current values;
Fixed threshold crossing alerts and too high/too
low available)
Physical layer (current values) LBCL
Physical layer LSRTEMP
(current values; Fixed threshold crossing alerts
and too high/too low available)
Ethernet PCS Layer  Rx-ES, Rx-CV
(15 min/24 h records with user configurable
threshold crossing alerts available)
Ethernet PCS Layer Tx-ES, Tx-CV
(15 min/24 h records with user configurable
threshold crossing alerts available)

This table shows information about performance monitoring of the network ports
in general.

Table 161: Performance Monitoring Network Interface - General


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Physical layer OPR; CD; DGD; SNR;


(15 min/24 h records available for PM values OPT; CFOT; LOCL;
except current values; LOTEMP
Fixed threshold crossing alerts and too high
available except SNR;
Fixed threshold crossing alerts and too low
available on OPR, CD, SNR, CFOT, OPT and
LOTEMP)
Physical layer (current values) LBCL
Physical layer LSRTEMP
(current values; Fixed threshold crossing
alerts and too high/too low available)

The following table gives information about performance monitoring of the


network ports in egress direction.

Table 162: Performance Monitoring Network Interface - Egress Direction


OTU4 FEC layer CE; UBE; BERCE
(15 min/24 h records with user
configurable threshold crossing alerts
available, except BERCE)
OTU4 layer - SM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)

Module and System Specification 147


WCC-PCTN-100GA

Table 162: Performance Monitoring Network Interface - Egress Direction


ODU4 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
TCMX layer ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
OPU layer ET; ERRFREE; AVGBER;
MAXBER

The following table contains information about the loop functionality.

Table 163: Loop Functionality


Client port Terminal and facility loop
Network ports Terminal and facility loop

The following table contains information about the link test functionality. This
test function is available on the network port only.

Table 164: Link Test PRBS Functionality


Initiate Transmit Test Enable/Release status

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Initiate Receive Test Enable/Release status
Reset test
Test elapsed time
Error free elapsed time
Loss of sequence synchronization
Average BER during Test
Maximum BER during Test

148 Module and System Specification


Chapter 3 Core Type Channel Modules

10TCC-PCTN-10G+100GB
The 10TCC-PCTN-10G+100GB is a 100G core type four-slot TDM channel
module (muxponder) with ten small form-factor pluggable (SFP+) interfaces on
the client side and an integrated single DWDM interface on the network side.
The network interface incorporating a dual polarization quadrature phase shift
keying (DP QPSK) modulation is fully tunable over the C band at 50 GHz
channel spacing. Input wavelength selection is supported by a coherent
receiver. The client-side optics are included within the SFP+ transceiver
modules. Each of the 10 client interfaces can be configured individually to any of
the supported client services.
The 10TCC-PCTN-10G+100GB provides muxponder functionality for the
transport of 10GbE WAN, STM64/OC192, 10GbE LAN, OTU2, OTU2e and
OTU1e client services over long-haul distances. Any combination of the
supported client services is possible. The network port supports OTU4V
according to ITU-T G.709 transmitted at a data rate of 120 Gbit/s. Soft Decision
FEC (SD-FEC) Enhanced FEC (EFEC) core for OTN signals is supported on
the OTU4 network port to enable ultra long reach performance.
The 10TCC-PCTN-10G+100GB provides fault management, performance
monitoring data and alarm generation for each the client ports as well as the
network port.
Table 165 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 165: Module - General Information


Equipment type 10TCC100GTB-D
First release 12.1
Width 16 HP
Height 5 HU
Weight 2860 g (6.305 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1e
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient 140,152 h
temperature
Typ. power consumption (incl. 10 150 W
pluggable transceivers)
Max. power consumption (incl. 10 170 W
pluggable transceivers)
Slot positions SH9HU: slots 3...15
NCU types NCU-II, NCU-II-P

The following table provides information about the client ports.

Table 166: Client Ports


Number of client ports 10
Type of client port SFP+

Module and System Specification 149


10TCC-PCTN-10G+100GB

Table 166: Client Ports (Continued)


Data rates 9.9532 Gbit/s, 10.3125 Gbit/s, 10.71 Gbit/s, 11.05
Gbit/s, 11.095 Gbit/s
Protocols OTU1e, OTU2, OTU2e, 10GbE LAN, SDH STM-64,
SONET OC-192, 10GbE WAN PHY1
1. STM-64 or OC-192 facility type has to be selected on the corresponding port
in the system management.

Table 167 provides information about jitter and wander compliance.

Table 167: Jitter and Wander Compliance


Jitter and wander GbE according to IEEE802.3 and G.8262 for
compliance for transparent transport of SyncE
GbE compliant for transparent transport of
1588v2 PTP frequency synchronization acc to
G.8265
STM-n according to G.783 and G.813

Table below provides a summary of the supported SFP+ client transceiver


types. Please refer to the specifications for the individual SFP+ transceiver type.

Table 168: Supported SFP+ Client Transceiver Types


850 nm type SFP+/11GU/850I/MM/LC

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
1310 nm type SFP+/11GU/1310S/SM/LC
CWDM type SFP+/11GU/CxxxxL/SM/LC

The following table contains information about the network port.

Table 169: Network Port


Number of network ports 1
Optical connector type LC
Fiber type SM 9 µm
Type of network port Tunable DWDM interface
Data rate 120.579 Gbit/s (includes 15%
overhead due to SD-FEC)
Protocol OTU4V
Transmitter output power range -5.0 dBm to +1.0 dBm
OPT measurement accuracy +/- 1.0 dB
Transmitter wavelength range Supports 96 C-band wavelengths on
50 GHz spacing with a tunable
interface from 1529.55 to 1567.54 nm
Modulation Format DP-QPSK with coherent detection
Wavelength stability (operating) +/- 60 pm
Max. cold startup time of controller 3 min
Max. cold startup time with new <15 min
optical link

150 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 169: Network Port (Continued)


Max. cold startup time with 3 min
unchanged optical link
Min. side mode suppression ratio 40 dB
Receiver wavelength range 1529.55 nm to 1567.54 nm
Receiver dynamic range -18 dBm to -2 dBm
OPR measurement accuracy +/- 0.5 dB
OPR measurement range -18.0 to -2.0 dBm
PMD tolerance 30 ps max.
CD tolerance -6,000 ps/nm to +60,000 ps/nm

To achieve a post-FEC BER better than 10-12, ADVA Optical


Networking recommends operating the network port of the
PS

module at pre-FEC BER values not higher than stated in the


Note following table.

This table provides information about the bit error rate versus OSNR.

Table 170: Bit Error Rate Versus OSNR


Pre FEC bit error ratio for 1.9 x 10-2 at 13.8 dB OSNR at 0.1 nm EOL
EFEC-61 with Post FEC bit error
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

ratio of 10-12

1. Soft-decision FEC providing 11.2 dB net coding gain.


The following table provides information about the operation modes and sup-
ported client services.

Table 171: Operation Modes


Unprotected terminal Up to 10 of any mix of the following service types:
multiplexer 10GbE LAN, OTU1e, OTU2, OTU2e, STM64/OC192
Channel Card Up to 10 of any mix of the following service types:
Protected terminal 10GbE LAN, OTU1e, OTU2, OTU2e, STM64/OC192
multiplexer

Table below provides information about the mapping and multiplexing schemes.

Table 172: Mapping and Multiplexing Schemes


Client service BMP mapping of client services into OPUk/ODUk
mapping (k=1e, 2, 2e) according to ITU-T Rec. G.709 02/12
ODTU4.ts mapping ODUk(L) k=1e,2,2e GMP mapped into ODTU4.8 in
accordance with ITU-T Rec. G.709
ODTU4.ts Network side multiplexing of ODTU4.8 into OPU4/
multiplexing ODTUG4 according to ITU-T Rec. G.709 02/12

Module and System Specification 151


10TCC-PCTN-10G+100GB

Table below provides information about the system performance.

Table 173: System Performance


Max. module delay <23.1µs for OTUk (k=1e,2,2e) to OTU4 with SD-FEC
Max. Ethernet 9224 bytes
Frame Size
Number of 7 using WCC-PCTN-100GB as back-to-back
regenerators regenerator

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

The following table provides information about fault monitoring on the module
equipment level in general.

Table 174: Fault Monitoring Equipment - General


Equipment Alarm Name TL-1 Keyword
Module Equipment removed RMVD
Equipment mismatch MEA__CONDITION
Voltage Out of Range VOLTANR
Equipment Fault HWFLT
Temperature High T-TEMP-FHT

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Temperature 2 High T-SUBTEMP-FHT
FWP-Mismatch (NSA) FWPM-NSA
FWP-Mismatch (SA) FWPM-SA
Client Port SFP+ Equipment Removed RMVD
Voltage Out of Range VOLTANR
Plug-Incompatible MEA-ACCEPT
Plug-Physical Mismatch MEA-PHYS
Plug-Not Approved MEA-APPROVE
Plug-Provision Mismatch MEA-DIFFER
Temperature High T-TEMP-FHT
Temperature Low T-TEMP-FLT

The following table provides information about fault monitoring of the client ports
in ingress direction.

Table 175: Fault Monitoring Client Interface - Ingress Direction


Layer Alarm Name TL-1 Keyword
Physical layer Rx Clock - Loss of Sync RCVCLK
Loss of signal LOS
Optical Power Rx High T-OPR-HT
Optical Power Rx Low T-OPR-LT
OCH/OTUk layer, OTU-Loss of Frame OTU-LOF
(k = 1e, 2, 2e) OTU-Loss of Multiframe OTU-LOM
OTU-AIS OTU-AIS

152 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 175: Fault Monitoring Client Interface - Ingress Direction (Continued)


OTU layer - SM OTU-BDI OTU-BDI
byte OTU-Signal Degrade OTU-SD
OTU-TIM OTU-TIM
ODUk layer - PM ODU-AIS ODU-AIS
byte,  ODU-BDI ODU-BDI
(k = 1e, 2, 2e) ODU-Open Connection ODU-OCI
ODU-Lock ODU-LCK
ODU-Signal Degrade ODU-SD
ODU-TIM ODU-TIM
ODUk layer - TCMx TCM_x-AIS AIS-TCMx
byte,  TCM_x-BDI BDI-TCMx
x= 1...6 TCM_x-Open Connection OCI-TCMx
TCM_x-Lock LCK-TCMx
TCM_x-Connection Loss LTC-TCMx
TCM_x-Signal Degrade SD-TCMx
TCM_x-TIM TIM-TCMx
TCM_x-BDI BDI-TCMx
Physical coding Loss of Char SYNC CHARSYNC
sublayer (Ethernet Bit Error Rate High HIBER
PCS)1 Local Fault LOCAL-Fault
1. valid for 10 GbE
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

The following table provides information about fault monitoring of the client ports
in egress direction.

Table 176: Fault Monitoring Client Interface - Egress Direction


Layer Alarm Name TL-1 Keyword
Physical layer Laser-fail LASER
Laser- Current Abnormal LBCLANR
Optical Power Tx High T-OPT-HT
Optical Power Tx Low T-OPT-LT
Auto Shutdown-Forward LKDO-OFF
Auto Shutdown (EPC) LKDO-EPC

The following table provides information about fault monitoring of the network
port in general.

Table 177: Fault Monitoring Network Interface - General


Layer Alarm Name TL-1 Keyword
Physical layer Laser-fail LASER
Rx Clock - Loss of Sync RCVCLK
Loss of signal LOS
Laser- Current Abnormal LBCLANR
Rx Laser - Abnormal LOCLANR

Module and System Specification 153


10TCC-PCTN-10G+100GB

This table provides information about fault monitoring of the network ports in
egress direction.

Table 178: Fault Monitoring Network Interface - Egress Direction


Layer Alarm Name TL-1 Keyword
OTU4 layer OTU-Loss of Lane
Alignment LOL-OTU
OTU-Loss of Frame LOF-OTU
OTU-Loss of multiframe LOM-OTU
OTU4 layer - SM byte OTU-BDI BDI-OTU
OTU-Signal Degrade SD-OTU
OTU-TIM TIM-OTU
ODU4 layer - PM byte ODU-AIS AIS-ODU
ODU-BDI BDI-ODU
ODU-Open Connection OCI-ODU
ODU-Lock LCK-ODU
ODU-Signal Degrade SD-ODU
ODU-TIM TIM-ODU
OPU4 layer Loss of Test Sync LSS
Payload Mismatch PLM
Loss of Frame Align LOOMFI
TCM layer AIS AIS
Open Connection OCI
Lock LCK

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Connection Loss LTC
TIM TIM
Signal Degrade SD
BDI BDI

The following table provides information about performance monitoring on the


module equipment level in general.
Table 179: Performance Monitoring - General
Layer Alarm Name TL-1 Keyword
Equipment Module temperature - TEMP
current analogue value
(Fix threshold crossing
alert for module
temperature too high
available)
SFP+ transceiver TEMP
temperature - current
analogue value
(Threshold crossing
alert for SFP+
transceiver
temperature too
high/too low TCA
thresholds available)

154 Module and System Specification


Chapter 3 Core Type Channel Modules

The following table provides information about performance monitoring values


supported on the client interfaces in ingress direction.

Table 180: Client Interface Ingress Performance Monitoring


Layer PM Name TL-1 Keyword
Physical layer Optical input power OPR
(15 min/24 h records for OPR Rx - current analogue
values available; user value
configurable threshold
crossing alerts for OPR Low,
OPR Mean OPR High; fix
threshold crossing alerts for
OPR High available)
FEC Layer FEC-Corrected Errors CE-FEC
(15min/24h records for these FEC-UBE UBE-FEC
PM values including user FEC-BERCE BERCE-FEC
configurable threshold
crossing alerts are available)
OTU layer OTU-Errored
(15min/24h records for these Seconds ES-OTU
PM values including user OTU-SES SES-OTU
configurable threshold OTU-BBE BBE-OTU
crossing alerts are available)
TCM layer TCM-Errored
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

(15min/24h records for these Seconds ES-TCM


PM values including user TCM-SES SES-TCM
configurable threshold TCM-BBE BBE-TCM
crossing alerts are available) TCM-UAS UAS-TCM
ODU layer  ODU-Errored ES-ODU
(15min/24h records for these Seconds
PM values including user ODU-SES SES-ODU
configurable threshold ODU-BBE BBE-ODU
crossing alerts are available) ODU-UAS UAS-ODU
PCS Layer Errored
(Current records for these PM Seconds-PCS ES-PCS
values) Code Violations-PCS CV-PCS
PCS Sync Header
Errors SE-PCS
Ethernet Layer Frames Rx FRRCV
(Current records for these PM CRC Errors Rx CRCFRRCV
values) Bytes Rx BYTERCV

Module and System Specification 155


10TCC-PCTN-10G+100GB

The following table provides information about performance monitoring values


supported on the client interfaces in egress direction.

Table 181: Client Interface Egress Performance Monitoring


Layer Alarm Name TL-1 Keyword
Physical layer Optical output power OPT
(15 min/24 h records for PM Tx - current analogue
values available; user value
configurable threshold Laser bias current LBCL
crossing alerts for OPT too level - current
high/too low available; fix analogue value
threshold crossing alerts for Laser temperature TEMP
OPT too high/too low
available)
Ethernet Layer Frames Tx FRTRMT
CRC Frames Tx CRCFTRMT
Bytes Tx BYTETRMT

This table shows information about performance monitoring of the network port
in general.

Table 182: Performance Monitoring Network Interface - General


Layer Alarm Name TL-1 Keyword
Physical layer OPR OPR

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
(15 min/24 h records available CD Compensation CD
for PM values except current Diff Group Delay DGD
values; SNR SNR
Fixed threshold crossing alerts OPT OPT
and too high available except Carrier Frequency
SNR; Offset CFOT
Fixed threshold crossing alerts Rx Laser Bias
and too low available on OPR, Current LOCL
CD, SNR, CFOT, OPT and Rx Laser
LOTEMP) Temperature LOTEMP
Physical layer (current values) Laser Bias Current LBCL
Physical layer Laser Temperature LSRTEMP
(current values; Fixed threshold
crossing alerts and too high/too
low available)

The following table gives information about performance monitoring of the


network port in egress direction.

Table 183: Performance Monitoring Network Interface - Egress Direction


Layer PM Name TL-1 Keyword
OTU4 FEC layer FEC-Corrected
(15 min/24 h records with Errors CE-FEC
user configurable threshold FEC-UBE UBE-FEC
crossing alerts available, FEC-BERCE BERCE-FEC
except BERCE)

156 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 183: Performance Monitoring Network Interface - Egress Direction


OTU4 layer - SM byte OTU-Errored
(15 min/24 h records with Seconds ES-OTU
user configurable threshold OTU-SES SES-OTU
crossing alerts available) OTU-UAS UAS-OTU
OTU-BBE BBE-OTU
ODU4 layer - PM byte ODU-Errored
(15 min/24 h records with Seconds ES-ODU
user configurable threshold ODU-SES SES-ODU
crossing alerts available) ODU-UAS UAS-ODU
ODU-BBE BBE-ODU
TCMx layer TCM_x-Errored ES-TCMx
(15 min/24 h records with Seconds
user configurable threshold TCM_x-SES SES-TCMx
crossing alerts available) TCM_x-UAS UAS-TCMx
TCM_x-BBE BBE-TCMx
OPU layer Elapsed Time ET
Error Free ERRFREE
Average Bit Error
Rate AVGBER
Max Measured BER MAXBER

The following table contains information about the loop functionality.


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 184: Loop Functionality


Client port Terminal and facility loopback
Network ports Terminal and facility loopback

The following table contains information about protection switching.

Table 185: Protection Switching


Protection scheme Client Channel card protection
Protection switching time <50 ms
Signal fail switching criteria physical Loss of Signal (LOS), LOC
Signal fail switching criteria OTN OTU-LOF, OTU-LOM, ODU-AIS,
ODU-LCK, ODU-OCI, OPU-PLM
Signal degrade switching criteria OTN SNC/N ODU-SD, (based on PM[2])
with provisionable threshold.
Support of enabling/disabling SD
based on PM[2] as protection.
Restoration scheme Versatile switched protection
(RSM-OLM, VSM)
Service Restoration Time TBD

Module and System Specification 157


10TCC-PCTN-10G+100GB

This table provides information about the ECC.

Table 186: Embedded Control Channel (ECC)


Network port One of the following DCN channels:
GCC0 (OTU4; 13702 kbit/s)
GCC1 (ODU4; 13702 kbit/s)
GCC2 (ODU4; 13702 kbit/s)
Client port One of the following DCN channels on each client port:
GCC0 (OTU; 1312kbit/s)
GCC1 (ODU; 1312kbit/s)
GCC2 (ODU; 1312kbit/s)

The following table contains information about the link test functionality. This
test function is available on the network port only.

Table 187: Link Test PRBS Functionality


Initiate Transmit Test Enable/Release status
Initiate Receive Test Enable/Release status
Reset test
Test elapsed time
Error free elapsed time
Loss of sequence synchronization
Average BER during Test
Maximum BER during Test

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

158 Module and System Specification


Chapter 3 Core Type Channel Modules

WCC-PCTN-10G
The WCC-PCTN-10G channel module is a 10G channel module with one XFP
type pluggable client interface and one tunable DWDM network interface.
It is intended for transport of STM-64/OC-192, 10G FC, 10 GbE LAN PHY, 
10 GbE WAN PHY, OTU2, OTU1e and OTU2e services. STM-64/OC-192, 10G
FC, 10 GbE LAN PHY and 10 GbE WAN PHY can be transmitted natively or,
with exception of 10G FC, can be mapped according to G.709 resulting in an
OTU2, OTU1e or OTU2e service.
GFEC can be enabled for OTU2, OTU1e and OTU2e services at both the client
port and the network port. EFEC-2 with higher coding gain is only supported on
the network port. For the support of OTU1e and OTU2e the module does not
meet the payload type standard. Only in that case OTU2e was implemented for
OTU2LAN with stuff bytes and OTU1e is used for OTU2LAN without stuff bytes.
The WCC-PCTN-10G module is available in three variants:
• WCC-PCTN-10G-LN#DC
• WCC-PCTN-10G-V#DC
• WCC-PCTN-10G-V#DL
The network ports of the WCC-PCTN-10G-LN#DC and WCC-PCTN-10G-V#DC
are fully tunable in the C band in a wavelength grid of 50 GHz. The network port
of the WCC-PCTN-10G-V#DL is fully tunable in the L band in a wavelength grid
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

of 100 GHz.
The WCC-PCTN-10G-V#DC, WCC-PCTN-10G-V#DL have very long reach
network interfaces whereas the WCC-PCTN-10G-LN#DC features a long reach
noise optimized network interface. Due to the high extinction ratio the
WCC-PCTN-10G-LN#DC is suitable for links with a large amount of amplifiers
and low OSNR.
The following table contains general information about all module variants and
their environment.

Table 188: Module - General Information for all Variants


Equipment type WCC10GT-D
First release 8.2 for WCC-PCTN-10G-LN#DC
8.3 for WCC-PCTN-10G-V#DC
9.2 for WCC-PCTN-10G-V#DL
MTBF at 25°C ambient temperature 198,774 h for WCC-PCTN-10G-LN#DC
232,195 h for WCC-PCTN-10G-V#DC
232,195 h for WCC-PCTN-10G-V#DL
Typ. power consumption (incl. XFP) 28 W
Max. power consumption (incl. 30 W
XFP)
Maximum RAM consumption on 365 Kbytes
NCU
Width 4 HP
Height 5 HU
Weight (incl. XFP) 650 g (1.4 lbs)

Module and System Specification 159


WCC-PCTN-10G

Table 188: Module - General Information for all Variants (Continued)


Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P

This table provides information about the client port for all variants.

Table 189: Client Port - Specifications for all Variants


Number of client ports 1
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s, 10.6642 Gbit/s,
10.7092 Gbit/s, 11.0491 Gbit/s,
11.0957 Gbit/s
Protocols STM-64, OC-192, 10 GbE LAN PHY,
10 GbE WAN PHY1, 10G FC, OTU2,
OTU1e (OTU2LAN without stuffing),
OTU2e (OTU2LAN with stuffing),

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ITU-T G.8262 and IEEE 1588v2
compliant transparent Ethernet
transport
Type of client ports XFP
1. STM-64 or OC-192 facility type has to be selected on the corresponding port
in the system management.

The following table provides a summary of the supported client XFPs. Please
refer to the specifications of the individual XFP type.

Table 190: Supported Client XFPs for all Variants


850 nm types XFP/10G/850I/MM/LC
1310 nm types XFP/11G/1310S/SM/LC
1550 nm types XFP/11G/1550L/SM/LC
CWDM types XFP/11G/CxxxxL/SM/LC
XFP/11G/CxxxxV/SM/LC
DWDM types XFP/11G/Dxxxx.xxV/SM/LC#Dxx

The following table provides information about the network port for all variants.

Table 191: Network Port - General Information for all Variants


Number of network ports 1
Optical connector type LC
Fiber type SM 9 µm
Type of network port Tunable DWDM interface

160 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 191: Network Port - General Information for all Variants (Continued)
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s, 10.6642 Gbit/s,
10.7092 Gbit/s, 11.0491 Gbit/s,
11.0957 Gbit/s
Protocols STM-64, OC-192, 10 GbE LAN PHY,
10 GbE WAN PHY1, 10G FC, OTU2,
OTU1e (OTU2LAN without stuffing),
OTU2e (OTU2LAN with stuffing)2
Tuning time (any channel to any < 45 s
oh.)
Tuning time cold start (any channel < 60 s
to any channel)
Max. shuttered output power -30 dBm
(dark tuning)
1. STM-64 or OC-192 facility type has to be selected on the corresponding port
in the system management.
2. 10G FC with FEC not supported

The following table provides information about the network port for the
WCC-PCTN-10G-LN#DC.

Table 192: Network Port - Optical Performance for WCC-PCTN-10G-LN#DC


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Transmitter output power range -3 dBm ... 0 dBm


Transmitter wavelength range 81 channels, 50 GHz spacing in C
band acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 60 pm
Min. extinction ratio 11 dB at 10.7092 Gbit/s
Min. side mode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -14 dBm ... -1 dBm
Receiver dynamic range for -16 dBm ... -1 dBm
operation with FEC starting Rel. 8.3
OPR measurement range -18 dBm ... 2 dBm
OPR/OPT accuracy +/- 2 dB
OSNR penalty at -16 dBm Rx input 1 dB
power
For operation without FEC or with
FEC in Rel. 8.2
OSNR penalty at -18 dBm Rx input 1 dB
power
For operation with FEC starting 
Rel. 8.3
Optimum dispersion load range -300 ps/nm ... +300 ps/nm
Dispersion load range with 1 dB -500 ps/nm ... -300 ps/nm and 
OSNR penalty +300 ps/nm ... +500 ps/nm
Dispersion load range with 2 dB -700 ps/nm ... -500 ps/nm and 
OSNR penalty +500 ps/nm ... +700 ps/nm

Module and System Specification 161


WCC-PCTN-10G

Table 192: Network Port - Optical Performance for WCC-PCTN-10G-LN#DC


OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)
OSNR penalty at 10 GbE LAN PHY 1 dB
with FEC (OTU1e and OTU2e)

This table provides information about the bit error rate versus OSNR for
WCC-PCTN-10G-LN#DC.

Table 193: Bit Error Rate Versus OSNR for WCC-PCTN-10G-LN#DC


Bit Error Ratio for operation without 10-12 at 23 dB OSNR
FEC
Pre-FEC Bit Error Ratio < 10-5 at 15 dB OSNR at 0.1 nm
For operation with FEC starting 
< 10-4 at 13 dB OSNR at 0.1 nm
Rel. 8.3 (ATC)1
< 10-3 at 12 dB OSNR at 0.1 nm
Pre-FEC Bit Error Ratio < 10-5 at 17 dB OSNR at 0.1 nm
For operation with FEC up to Rel. 8.2
< 10-4 at 15 dB OSNR at 0.1 nm
(without ATC)
< 10-3 at 14 dB OSNR at 0.1 nm
1. To achieve the specified Pre-Fec Bit error ratio at OSNR values below 13 dB
the ATC may need up to 10 minutes for adjusting the threshold.

The following table provides information about the network port for the

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
WCC-PCTN-10G-V#DC.

Table 194: Network Port - Optical Performance for WCC-PCTN-10G-V#DC


Transmitter output power range 4 dBm ... 6 dBm
Transmitter wavelength range 81 channels, 50 GHz spacing in C
band acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 60 pm
Min. extinction ratio 10 dB
Min. side mode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -20 dBm ... -8 dBm
OPR measurement range -22 dBm ... -5 dBm
OPR/OPT accuracy +/- 2 dB
OSNR penalty at -22 dBm Rx input 1 dB
power
Optimum dispersion load range +200 ps/nm ... +900 ps/nm
Dispersion load range with 1 dB -150 ps/nm ... +200 ps/nm and 
OSNR penalty +900 ps/nm ... +1250 ps/nm
Dispersion load range with 2 dB -500 ps/nm ... -150 ps/nm and 
OSNR penalty +1250 ps/nm ... +1600 ps/nm
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)
OSNR penalty at 10 GbE LAN PHY 1 dB
with FEC (OTU1e, OTU2e)

162 Module and System Specification


Chapter 3 Core Type Channel Modules

This table provides information about the bit error rate versus OSNR for
WCC-PCTN-10G-V#DC.

Table 195: Bit Error Rate Versus OSNR for WCC-PCTN-10G-V#DC


Pre-FEC Bit < 10-12 at 25 dB OSNR at 0.1 nm
Error Ratio
< 10-9 at 23 dB OSNR at 0.1 nm
< 10-5 at 19 dB OSNR at 0.1 nm
< 10-4 at 17 dB OSNR at 0.1 nm
< 10-3 at 16 dB OSNR at 0.1 nm

The following table provides information about the network port for the
WCC-PCTN-10G-V#DL.

Table 196: Network Port - Optical Performance for WCC-PCTN-10G-V#DL


Transmitter output power range 3 dBm ... 5 dBm
Transmitter wavelength range 41 channels, 100 GHz spacing in L
band acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 100 pm
Min. extinction ratio 9 dB
Min. side mode suppression ratio 35 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -20 dBm ... -8 dBm
OPR measurement range -22 dBm ... -5 dBm
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

OPR/OPT accuracy +/- 2 dB


OSNR penalty at -22 dBm Rx input 1 dB
power
Optimum dispersion load range +200 ps/nm ... +900 ps/nm
Dispersion load range with 1 dB -150 ps/nm ... +200 ps/nm and 
OSNR penalty +900 ps/nm ... +1250 ps/nm
Dispersion load range with 2 dB -500 ps/nm ... -150 ps/nm and 
OSNR penalty +1250 ps/nm ... +1600 ps/nm
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)
OSNR penalty at 10 GbE LAN PHY 1 dB
with FEC (OTU1e, OTU2e)

Module and System Specification 163


WCC-PCTN-10G

This table provides information about the bit error rate versus OSNR for
WCC-PCTN-10G-V#DL.

Table 197: Bit Error Rate Versus OSNR for WCC-PCTN-10G-V#DL


Pre-FEC Bit Error Ratio < 10-12 at 25 dB OSNR at 0.1 nm
< 10-9 at 23 dB OSNR at 0.1 nm
< 10-5 at 19 dB OSNR at 0.1 nm
< 10-4 at 17 dB OSNR at 0.1 nm
< 10-3 at 16 dB OSNR at 0.1 nm

To achieve a post-FEC BER better than 10-12, ADVA Optical


Networking recommends operating the network port of the
PS

module at pre-FEC BER values not higher than stated in the


Note following table.

This table shows the recommended maximum pre-FEC bit error ratio for all
variants.

Table 198: Recommended Maximum Pre-FEC BER for all Variants


GFEC 1 x 10-5
EFEC-2 5 x 10-4

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table contains information about the system performance for all variants.
Table 199: System Performance for all Variants
Max. module 3 µs with all supported protocols excepting OTU2 at the client
delay without port and with all supported protocols without FEC at the
client XFP network port;
10 µs with all supported protocols excepting OTU2 at the
client port and with OTU2 and GFEC at the network port;
55 µs with all supported protocols excepting OTU2 at the
client port and with OTU2 and EFEC-2 at the network port;
10 µs with OTU2 and with or without GFEC at the client port
and with OTU2 and without FEC at the network port;
20 µs with OTU2 and with or without GFEC at the client port
and with OTU2 and GFEC at the network port;
65 µs with OTU2 and with or without GFEC at the client port
and with OTU2 and EFEC-2 at the network port
Number of 15 using 2WCC-PCN-10G as bidirectional single module
regenerators N-N regenerator (OTU2, OTU1e and OTU2e with EFEC-2
only)
7 using 2WCC-PCN-10G as bidirectional single module C-N
regenerator (no FEC or GFEC on client ports only)
7 using WCC-PCTN-10G as back-to-back regenerator
(SDH/SONET/OTN only).
3 using 2WCA-PCN-10G (FEC bypass, C band, ALS
disabled) as bidirectional single module C-N regenerator
(SDH/SONET/10 GbE/10G FC and OTU2 with 10.709 Gbit/s
only).

164 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 199: System Performance for all Variants (Continued)


Max. frame no limitation in transmission (for performance monitoring
size limited to 16387 bytes)

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

This table shows information about fault monitoring of the module in general for
all variants.

Table 200: Fault Monitoring - General for all Variants


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Client port XFP missing;
Client port XFP mismatch

This table shows information about fault monitoring of the client ports for all
variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 201: Fault Monitoring Client Interface - General for all Variants
Physical layer Laser failure; Laser degrade (based
on bias current); Receiver clock synch
failure; Loss of signal (LOS)

The following table gives information about fault monitoring of the client ports in
ingress direction for all variants.

Table 202: Fault Monitoring Client Interface - Ingress Direction for all
Variants
STM-64 RS/OC-192 section layer LOF; TIM
STM-64 MS/OC-192 line layer AIS; RDI; SD
OCH/OTU2 layer LOF; LOM; AIS
OTU2 layer - SM byte BDI; SD; TIM
ODU2 layer - PM byte AIS; BDI; OCI; LCK; SD; TIM
ODU2 layer - TCMi byte, i = 1...6 AIS; BDI; OCI; LCK; LTC; SD; TIM
Physical coding sublayer  Loss of synchronization; Hi_BER;
(PCS 64B66B)1 Local fault; SD
1. valid for 10 GbE LAN PHY and 10G FC

Module and System Specification 165


WCC-PCTN-10G

This table shows information about fault monitoring of the network ports for all
variants.

Table 203: Fault Monitoring Network Interface - General for all Variants
Physical layer Laser failure; Receiver clock synch
failure; Loss of signal (LOS); Optical
power Rx too high/too low (OPR);
Optical power Tx too high/too low
(OPT)

This table provides information about fault monitoring of the network ports in
egress direction for all variants.

Table 204: Fault Monitoring Network Interface - Egress Direction for all
Variants
STM-64 RS/OC-192 section layer LOF; TIM
STM-64 MS/OC-192 line layer AIS; RDI; SD
OCH/OTU2 layer LOF; LOM; AIS
OTU2 layer - SM byte BDI; SD; TIM
ODU2 layer - PM byte AIS; BDI; OCI; LCK; SD; TIM
ODU2 layer -TCMi byte, i = 1 ... 6 AIS; BDI; OCI; LCK; LTC; SD; TIM
OPU2 layer AIS; PLM
Physical coding sublayer Loss of synchronization; Hi_BER;
(PCS 64B66B)1 Local fault; SD

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
1. valid for 10 GbE LAN PHY and 10G FC

The following table provides information about performance monitoring of the


module in general for all variants.

Table 205: Performance Monitoring - General for all Variants


Equipment Module temperature (current value)
(Fix threshold crossing alert for
module temperature too high
available)

This table shows information about performance monitoring of the client ports
for all variants.

Table 206: Performance Monitoring Client Interface - General for all Variants
Physical layer Transmitter bias current
(15 min/24 h records available for PM (current);
values except current values; Optical power Rx (current, low,
user configurable threshold crossing mean, high);
alerts for OPR too high/too low available; Optical power Tx (current, low,
fix threshold crossing alerts for OPT too mean, high)
high/too low available)

166 Module and System Specification


Chapter 3 Core Type Channel Modules

The following table gives information about performance monitoring of the client
ports in ingress direction for all variants.

Table 207: Performance Monitoring Client Interface - Ingress Direction for all
Variants
STM-64 RS/OC-192 section layer ES; SES; OOFS/SEFS;
(15 min/24 h records with user BBE/CV
configurable threshold crossing alerts
available)
STM-64 MS/OC-192 line layer ES; SES; UAS; BBE/CV
(15 min/24 h records with user
configurable threshold crossing alerts
available)
OCH/OTU2 layer ES; SES; UBE; CE
(15 min/ 24 h records with user
configurable threshold crossing alerts
available)
OTU2 layer - SM byte ES; SES; UAS; BBE
(15 min/ 24 h records with user
configurable threshold crossing alerts
available)
ODU2 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

ODU2 layer - TCMi byte, i = 1 ... 6 ES; SES; UAS; BBE


(15 min/24 h records with user
configurable threshold crossing alerts
available)
Physical coding sublayer (PCS 64B66B)1 ES; CV; SE
Framed 10 GbE services RX Good frames; RX Pause
frames; RX CRC frames;
Received bytes
1. valid for 10 GbE LAN PHY and 10G FC

The following table gives information about performance monitoring of the client
ports in egress direction for all variants.

Table 208: Performance Monitoring Client Interface - Egress Direction for all
Variants
Framed 10 GbE services TX Good frames; TX Pause
frames; TX CRC frames;
Transmitted bytes

Module and System Specification 167


WCC-PCTN-10G

This table shows information about performance monitoring of the network ports
for all variants.

Table 209: Performance Monitoring Network Interface for all Variants


Physical layer Transmitter bias current
(15 min/24 h records available for PM (current);
values except current values; Optical power Rx (current, low,
user configurable threshold crossing alerts mean, high);
for OPR too high/too low available; Optical power Tx (current, low,
fix threshold crossing alerts for OPT too mean, high)
high/too low available)
STM-64 RS/OC-192 section layer ES; SES; OOFS/SEFS;
(15 min/24 h records with user BBE/CV
configurable threshold crossing alerts
available)
STM-64 MS/OC-192 line layer ES; SES; UAS; BBE/CV
(15 min/24 h records with user
configurable threshold crossing alerts
available)
OCH/OTU2 layer ES; SES; UBE; CE
(15 min/ 24 h records with user
configurable threshold crossing alerts
available)
OTU2 layer - SM byte ES; SES; UAS; BBE
(15 min/ 24 h records with user

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
configurable threshold crossing alerts
available)
ODU2 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
ODU2 layer - TCMi byte, i = 1 ... 6 ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
Physical coding sublayer (PCS 64B66B)1 ES; CV; SE
Framed 10 GbE services RX Good frames; RX Pause
frames; RX CRC frames;
Received bytes
1. valid for 10 GbE LAN PHY and 10G FC

The following table provides information about the loop functionality for all
variants.

Table 210: Loop Functionality for all Variants


Client port Facility loop, Terminal loop
Network ports Facility loop, Terminal loop

168 Module and System Specification


Chapter 3 Core Type Channel Modules

This table provides information about protection switching for all variants.

Table 211: Protection Switching for all Variants


Protection scheme Channel card protection
Protection switching time < 50 ms
Signal fail switching criteria LOS, Receiver clock synch failure
physical
Signal fail switching criteria LOF-S
STM-64/OC-192
Signal fail switching criteria OTN OTU-LOF, OTU-AIS, OTU-LOM,
ODU-AIS, ODU-LCK, ODU-OCI
Signal degrade switching criteria SD-L (MS-DEG/SD based on B2) with
STM-64/OC-192 provisionable threshold.
Support of enabling/disabling SD-L
based on B2 as protection.
Signal degrade switching criteria SNC/N ODU-SD (based on PM[2])
OTN with provisionable threshold.
Support of enabling/disabling SD
based on PM[2] as protection.
Physical coding switching criteria PCS-SD (for 10 GbE only), Loss of
Synch, HI_BER, Local Fault
Restoration scheme Versatile switched protection,
The module must not be configured to
channel card protection.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

(RSM-SF, RSM-OLM, VSM)


Restoration time <1s

This table provides information about the ECC for all variants.

Table 212: Embedded Control Channel (ECC) for all Variants


Network port SDCC (192 kbit/s), GCC0 (1312 kbit/s)
GCC0S (82 kbit/s), GCC1 (1312 kbit/s)
GCC2 (1312 kbit/s), Proprietary ECC
for wrapped 10 GbE (1359 kbit/s)
Client port SDCC (192 kbit/s), GCC0 (1312 kbit/s)
GCC0S (82 kbit/s), GCC1 (1312 kbit/s)
GCC2 (1312 kbit/s), Proprietary ECC
for wrapped 10 GbE (1359 kbit/s)

Module and System Specification 169


4TCC-PCTN-2G7+10G

4TCC-PCTN-2G7+10G
The 4TCC-PCTN-2G7+10G module is a 4-port time division multiplexing
channel modules with SFP type pluggable client interfaces. The client ports
support STM-16/OC-48 and OTU1. These services are multiplexed according to
OTN as described in ITU-T G.709 using transparent asynchronous aggregation
of ODU1 tributaries into OTU2. STM-16/OC-48 client interface signals at 2.488
Gbit/s are either transported transparently or regenerated at the RS/Section
layer. The client interface signals are end-to-end clock transparent and can be
used for clock distribution, but holdover is not supported. If demultiplexing fails,
a local 20 ppm oscillator will be used as clock source. The OTU1 client interface
signals at 2.666 Gbit/s are terminated at the OTU1 SM layer, and the ODU1 PM
is transparently multiplexed into OPU2. The network port supports OTU2 with
GFEC at 10.709 Gbit/s or OTU2V with EFEC-1 at 11.003 Gbit/s.
The module is available in three variants:
• 4TCC-PCTN-2G7+10G-LN#DC
• 4TCC-PCTN-2G7+10G-V#DC
• 4TCC-PCTN-2G7+10G-V#DL
The network ports of the 4TCC-PCTN-2G7+10G-LN#DC and
4TCC-PCTN-2G7+10G-V#DC are fully tunable in the C band in a wavelength
grid of 50 GHz.
The network port of the 4TCC-PCTN-2G7+10G-V#DL is fully tunable in the L

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
band in a wavelength grid of 100 GHz. The 4TCC-PCTN-2G7+10G-V#DC and
4TCC-PCTN-2G7+10G-V#DL have very long reach network interfaces whereas
the 4TCC-PCTN-2G7+10G -LN#DC features a long reach noise optimized
network interface. Due to the high extinction ratio the
4TCC-PCTN-2G7+10G-LN#DC is suitable for links with a large amount of
amplifiers and low OSNR.
Table 213 contains general information about all module variants and their
environment.

Table 213: Module - General Information for all Variants


Equipment type 4TCC10GT-D
First release 8.2 for 4TCC-PCTN-2G7+10G-LN#DC
8.3 for 4TCC-PCTN-2G7+10G-V#DC
8.3 for 4TCC-PCTN-2G7+10G-V#DL
MTBF at 25°C ambient 251,483 h for 4TCC-PCTN-2G7+10G-LN#DC
temperature 290,966 h for 4TCC-PCTN-2G7+10G-V#DC
290,966 h for 4TCC-PCTN-2G7+10G-V#DL
Typ. power consumption 33 W
(incl. SFPs)
Max. power consumption 37 W
(incl. SFPs)
Maximum RAM 898 Kbytes
consumption on NCU
Width 8 HP
Height 5 HU

170 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 213: Module - General Information for all Variants (Continued)


Weight (incl. SFPs) 1.3 kg (2.9 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection IP20. Use in a pollution degree 2 environment
according to and indoor controlled office environments only.
IEC 60529
Slot positions SH9HU: 3...17
SH7HU, SH7HU-R: 3...17
SH1HU: 1
NCU types NCU, NCU-II, NCU-II-P

This table provides information about the client ports for all variants.

Table 214: Client Ports - Specifications for all Variants


Number of client ports 4
Data rates 2.48832 Gbit/s, 2.666057 Gbit/s
Protocols STM-16, OC-48, OTU1
Type of client ports SFP

The following table provides a summary of the supported client SFPs. Please
refer to the specifications for the individual SFP type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 215: Supported Client SFPs for all Variants


1310 nm types SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
CWDM types SFP/2G5U/CxxxxL/SM/LC
SFP/2G5U/CxxxxV/SM/LC
DWDM types SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx 
(C band only)

This table provides information about the network port for all variants.

Table 216: Network Port - General Information for all Variants


Number of network ports 1
Optical connector type LC
Fiber type SM 9 µm
Type of network port Tunable DWDM interface
Data rates 10.7092 Gbit/s, 11.0032 Gbit/s
Protocols OTU2, OTU2V
Tuning time (any channel to any < 45 s
ch.)
Tuning time cold start < 60 s
(any channel to any channel)
Max. shuttered output power -30 dBm
(dark tuning)

Module and System Specification 171


4TCC-PCTN-2G7+10G

The following table provides information about the network port for the
4TCC-PCTN-2G7+10G-LN#DC.

Table 217: Network Port- Optical Performance for


4TCC-PCTN-2G7+10G-LN#DC
Transmitter output power range -3 dBm ... 0 dBm
Transmitter wavelength range 81 channels, 50 GHz spacing in C
band at acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 60 pm
Min. extinction ratio 11 dB at 10.7092 Gbit/s
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -14 dBm ... -1 dBm
Receiver dynamic range for -16 dBm ... -1 dBm
operation with FEC starting Rel. 8.3
OPR measurement range -16 dBm ... 2 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range -300 ps/nm ... +300 ps/nm
Dispersion load range with 1 dB -500 ps/nm ... -300 ps/nm and 
OSNR penalty +300 ps/nm ... +500 ps/nm
Dispersion load range with 2 dB -700 ps/nm ... - 500 ps/nm and 
OSNR penalty +500 ps/nm ... +700 ps/nm
OSNR PMD penalty 1 dB at 10 ps 
(outage probability 4x10-5)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
OSNR penalty at -16 dBm Rx input 1 dB
power
For operation without FEC or with
FEC in Rel. 8.2
OSNR penalty at -18 dBm Rx input 1 dB
power
For operation with FEC starting
Rel. 8.3
OSNR penalty at 11.0032 Gbit/s 1 dB

This table provides information about the bit error rate versus OSNR for
4TCC-PCTN-2G7+10G-LN#DC.

Table 218: Bit Error Rate Versus OSNR for 4TCC-PCTN-2G7+10G-LN#DC


Bit Error Ratio for operation without < 10-12 at 23 dB OSNR at 0.1 nm
FEC
Pre-FEC Bit Error Ratio < 10-9 at 19 dB OSNR at 0.1 nm
For operation with FEC starting 
< 10-5 at 15 dB OSNR at 0.1 nm
Rel. 8.3 (ATC)1
< 10-4 at 13 dB OSNR at 0.1 nm
< 10-3 at 12 dB OSNR at 0.1 nm
Pre-FEC Bit Error Ratio < 10-9 at 21 dB OSNR at 0.1 nm
For operation with FEC up to Rel. 8.2
< 10-5 at 17 dB OSNR at 0.1 nm
(without ATC)
< 10-4 at 15 dB OSNR at 0.1 nm
< 10-3 at 14 dB OSNR at 0.1 nm

172 Module and System Specification


Chapter 3 Core Type Channel Modules

1. To achieve the specified Pre-Fec Bit error ratio at OSNR values below 13 dB
the ATC may need up to 10 minutes for adjusting the threshold.

The following table provides information about the network port for the
4TCC-PCTN-2G7+10G-V#DC.

Table 219: Network Port- Optical Performance for


4TCC-PCTN-2G7+10G-V#DC
Transmitter output power range +4 dBm ... +6 dBm
Transmitter wavelength range 81 channels, 50 GHz spacing in C
band acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 60 pm
Min. extinction ratio 10 dB
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -20 dBm ... -8 dBm
OPR measurement range -22 dBm ... -5 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range +200 ps/nm ... +900 ps/nm
Dispersion load range with 1 dB -150 ps/nm ... +200 ps/nm and 
OSNR penalty +900 ps/nm ... +1250 ps/nm
Dispersion load range with 2 dB -500 ps/nm ... -150 ps/nm and 
OSNR penalty +1250 ps/nm ... +1600 ps/nm
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

OSNR PMD penalty 1 dB at 10 ps 


(outage probability 4x10-5)
OSNR penalty at -22 dBm input 1 dB
power
OSNR penalty at 11.0032 Gbit/s 1 dB

This table provides information about the bit error rate versus OSNR for
4TCC-PCTN-2G7+10G-V#DC.
Table 220: Bit Error Rate Versus OSNR for 4TCC-PCTN-2G7+10G-V#DC
Pre-FEC Bit Error Ratio < 10-12 at 25 dB OSNR at 0.1 nm
< 10-9 at 23 dB OSNR at 0.1 nm
< 10-5 at 19 dB OSNR at 0.1 nm
< 10-4 at 17 dB OSNR at 0.1 nm
< 10-3 at 16 dB OSNR at 0.1 nm

The following table provides information about the network port for the
4TCC-PCTN-2G7+10G-V#DL.

Table 221: Network Port- Optical Performance for


4TCC-PCTN-2G7+10G-V#DL
Transmitter output power range +3 dBm ... +5 dBm
Transmitter wavelength range 41 channels, 100 GHz spacing in L
band acc. to ITU-T G.694 (tunable)

Module and System Specification 173


4TCC-PCTN-2G7+10G

Table 221: Network Port- Optical Performance for


4TCC-PCTN-2G7+10G-V#DL (Continued)
Wavelength stability (operating) +/- 100 pm
Min. extinction ratio 10 dB
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -20 dBm ... -8 dBm
OPR measurement range -22 dBm ... -5 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range +200 ps/nm ... +900 ps/nm
Dispersion load range with 1 dB -150 ps/nm ... +200 ps/nm and 
OSNR penalty +900 ps/nm ... +1250 ps/nm
Dispersion load range with 2 dB -500 ps/nm ... -150 ps/nm and 
OSNR penalty +1250 ps/nm ... +1600 ps/nm
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)
OSNR penalty at -22 dBm input 1 dB
power
OSNR penalty at 11.0032 Gbit/s 1 dB

This table provides information about the bit error rate versus OSNR for
4TCC-PCTN-2G7+10G-V#DL.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 222: Bit Error Rate Versus OSNR for 4TCC-PCTN-2G7+10G-V#DL
Pre-FEC Bit Error Ratio < 10-12 at 25 dB OSNR at 0.1 nm
< 10-9 at 23 dB OSNR at 0.1 nm
< 10-5 at 19 dB OSNR at 0.1 nm
< 10-4 at 17 dB OSNR at 0.1 nm
< 10-3 at 16 dB OSNR at 0.1 nm

To achieve a post-FEC BER better than 10-12, ADVA Optical


Networking recommends operating the network port of the
PS

module at pre-FEC BER values not higher than stated in the


Note following table.

This table shows recommended maximum pre-FEC bit error ratio for all variants.

Table 223: Recommended Maximum Pre-FEC BER for all Variants


GFEC 1 x 10-5
EFEC-1 5 x 10-4

174 Module and System Specification


Chapter 3 Core Type Channel Modules

The following table provides information about the multiplexing scheme for all
variants.

Table 224: Multiplexing Scheme for all Variants


STM-16/OC-48 client signals wrapped into ODU1
4 x ODU1 multiplexed into OTU2
OTU1 client signals termination of OTU1
ODU1 multiplexed into OTU2

The following table contains information about the system performance for all
variants.

Table 225: System Performance for all Variants


Max. module delay 20 µs without FEC, 20 µs with GFEC,
150 µs with EFEC-1
Number of regenerators 7 using 2WCC-PCN-10G as
bidirectional single module C-N
regenerator (no FEC or GFEC on
client ports only)
7 using WCC-PCTN-10G without
EFEC-1 as back-to-back regenerator
3 using 2WCA-PCN-10G (FEC
bypass, C band, ALS disabled) as
bidirectional single module C-N
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

regenerator.
Number of back-to-back cascades 7 using 4TCC-PCTN-2G7+10G
(without protection capability)

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

This table shows information about fault monitoring of the module in general for
all variants.

Table 226: Fault Monitoring - General for all Variants


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Client port SFP missing;
Client port SFP mismatch;

Module and System Specification 175


4TCC-PCTN-2G7+10G

This table shows information about fault monitoring of the client ports for all
variants.

Table 227: Fault Monitoring Client Interface - General for all Variants
Physical layer Laser failure;
Laser degrade (based on bias
current);
Receiver clock synch failure;
Loss of signal (LOS)

The following table gives information about fault monitoring of the client ports in
ingress direction for all variants.

Table 228: Fault Monitoring Client Interface - Ingress Direction for all
Variants
STM-16 RS/OC-48 section layer LOF; TIM
STM-16 MS/OC-48 line layer AIS; RDI
OCH/OTU1 layer LOF; LOM; AIS
OTU1 layer - SM byte BDI; SD; TIM
ODU1 layer - PM byte AIS; BDI; OCI; LCK; SD; TIM
ODU1 layer - TCMi byte, i = 1...6 AIS; BDI; OCI; LCK; LTC; SD; TIM

This table shows information about fault monitoring of the client ports in egress
direction for all variants.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 229: Fault Monitoring Client Interface - Egress Direction for all
Variants
STM-16 RS/OC-48 section layer LOF
ODU1 layer - PM byte AIS; BDI; OCI; LCK; Loss of
frame/multiframe (LOFLOM); SD; TIM
OPU1 layer AIS; PLM

This table shows information about fault monitoring of the network ports for all
variants.

Table 230: Fault Monitoring Network Interface - General for all Variants
Physical layer Laser failure;
Receiver clock synch failure;
Loss of signal (LOS)

This table provides information about fault monitoring of the network ports in
egress direction for all variants.

Table 231: Fault Monitoring Network Ports - Egress Direction for all Variants
OCH/OTU2 layer LOF; LOM; AIS
OTU2 layer - SM byte BDI; SD; TIM
ODU2 layer - PM byte AIS; BDI; OCI; LCK; SD; TIM
ODU2 layer -TCMi byte, i = 1 ... 6 AIS; BDI; OCI; LCK; SD; TIM
OPU2 layer PLM; MSIM

176 Module and System Specification


Chapter 3 Core Type Channel Modules

The following table provides information about performance monitoring of the


module in general for all variants.

Table 232: Performance Monitoring - General for all Variants


Equipment Module temperature (current value)
(Fix threshold crossing alert for
module temperature too high
available)

This table shows information about performance monitoring of the client ports
for all variants.

Table 233: Performance Monitoring Client Interface - General for all Variants
Physical layer Transmitter bias current
(15 min/24 h records available for PM (current);
values except current values; Optical power Rx (current, low,
user configurable threshold crossing mean, high);
alerts for OPR too high/too low available; Optical power Tx (current, low,
fix threshold crossing alerts for OPT too mean, high)
high/too low available)

The following table gives information about performance monitoring of the client
ports in ingress direction for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 234: Performance Monitoring Client Interface - Ingress Direction for all
Variants
STM-16 RS/OC-48 section layer ES; SES; OOFS/SEFS;
(15 min/24 h records with user BBE/CV
configurable threshold crossing alerts
available)
STM-16 MS/OC-48 line layer ES; SES; UAS; BBE/CV
(15 min/24 h records with user
configurable threshold crossing alerts
available)
OTU1 layer - SM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
ODU1 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
Physical coding sublayer (PCS) SD; Loss of character
synchronization
ODU1 layer - TCMi byte, i = 1 ... 6 ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)

Module and System Specification 177


4TCC-PCTN-2G7+10G

The following table gives information about performance monitoring of the client
ports in egress direction for all variants.
Table 235: Performance Monitoring Client Interface - Egress Direction for all
Variants
ODU1 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)

This table shows information about performance monitoring of the network ports
for all variants.

Table 236: Performance Monitoring Network Interface - General for all


Variants
Physical layer Optical power Rx
(15 min/24 h records available for PM values except (current, low, mean,
current values; user configurable threshold crossing high);
alerts for OPR too high/too low available; Optical power Tx
fix threshold crossing alerts for OPT too high/too low (current, low, mean,
available) high)

The following table gives information about performance monitoring of the


network ports in egress direction for all variants.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 237: Performance Monitoring Network Interface - Egress Direction for
all Variants
OCH/OTU2 layer CE; UBE; ES; SES
(15 min/24 h records with user
configurable threshold crossing alerts
available)
OTU2 layer - SM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
ODU2 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
ODU2 layer - TCMi byte, i = 1 ... 6 ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)

This table shows information about the loop functionality for all variants.

Table 238: Loop Functionality for all Variants


Client ports Terminal loop on individual port
Facility loop on individual port
Network port Terminal loop, Facility loop

178 Module and System Specification


Chapter 3 Core Type Channel Modules

This table provides information about protection switching for all variants.

Table 239: Protection Switching for all Variants


Protection scheme Channel card protection
Protection switching time < 50 ms
Switching criteria LOS, Receiver clock synch failure,
OTU2-LOF, OTU2-LOM, OTU2-AIS,
ODU2-PM-AIS, ODU2-PM-OCI,
ODU2-PM-LCK, ODU2-PM-SD
Restoration scheme Versatile switched protection,
The module must not be configured to
channel card protection.
(RSM-SF, RSM-OLM, VSM)
Restoration time <1s

The following table contains information about the ECC for all variants.

Table 240: Embedded Control Channel (ECC) for all Variants


Notice: One GCC or DCC channel is supported per port
Client ports SDCC (192 kbit/s), GCC0 (326 kbit/s)
GCC1 (326 kbit/s), GCC2 (326 kbit/s)
GCC0S (82 kbit/s)
Network port GCC0 (1312 kbit/s), GCC0S (82 kbit/s)
GCC1 (1312 kbit/s), 
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

GCC2 (1312 kbit/s)

Module and System Specification 179


10TCC-PCTN-4GUS+10G

10TCC-PCTN-4GUS+10G
The 10TCC-PCTN-4GUS+10G channel modules are 10-port TDM channel
modules with pluggable client interfaces and one fixed 10 G long reach link,
tunable DWDM network interface. The network port is tunable in the C band or L
band, depending on the module variant.
The 10TCC-PCTN-4GUS+10G module is available in three variants:
• 10TCC-PCTN-4GUS+10G-LN#DC
• 10TCC-PCTN-4GUS+10G-V#DC
• 10TCC-PCTN-4GUS+10G-V#DL
The network port is configurable to either OTN or SDH/SONET. When running
OTN, three FEC operational modes are configurable:
• standard FEC,
• enhanced FEC and
• FEC bypass.
When the network interface is configured as OTN, the network transmission rate
is 10.709 Gbit/s.
In SDH/SONET mode, the network interface transmits at 9.953 Gbits/s.
The client interfaces support GbE, 1G FC, 2G FC, 4G FC, STM-1/OC-3,
STM-4/OC-12 and STM-16/OC-48 services.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The mixture of any of these services is possible as long as the total amount of
VC4s/STS-3c-SPEs is not exceeded.
The network ports of the 10TCC-PCTN-4GUS+10G-LN#DC and
10TCC-PCTN-4GUS+10G-V#DC are fully tunable in the C band to 50 GHz
wavelength spacing. In the L band, the network port of the
10TCC-PCTN-4GUS+10G-V#DL is fully tunable to 100 GHz wavelength
spacing.
The 10TCC-PCTN-4GUS+10G-V#DC and 10TCC-PCTN-4GUS+10G-V#DL
have very long reach network interfaces.
The 10TCC-PCTN-4GUS+10G-LN#DC features a long reach noise optimized
network interface. With a higher extinction ratio, it is suitable for links with a
higher number of amplifiers and a lower OSNR.

This module is not compatible with ITU-T G.813 and cannot be used
PS

for SDH/SONET clock distribution


Note

180 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 241 contains general information about all module variants and their
environment.

Table 241: Module - General Information for all Variants


Equipment type 10TCCS10GT-D
First release 9.3
MTBF at 25°C ambient 254,750 h
temperature
Typ. power consumption 55 W
(incl. SFPs)
Max. power consumption 67 W
(incl. SFPs)
Maximum RAM consumption on 2,205 Kbytes
NCU
Width 8 HP
Height 5 HU
Weight (incl. SFPs) 1.6 kg (3.5 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according IP20. Use in a pollution degree 2
to environment and indoor controlled office
IEC 60529 environments only.
Slot positions SH9HU: 3...17
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

SH7HU, SH7HU-R: 3...17


SH1HU: 1
NCU types NCU, NCU-II, NCU-II-P

The following table provides information about the client ports for all variants.

Table 242: Client Ports - Specifications for all Variants


Number of client ports 10
Data rates 155 Mbit/s, 622 Mbit/s, 2.48832 Gbit/s,
1.250 Gbit/s, 1.0625 Gbit/s, 2.125 Gbit/s
or 4.250 Gbit/s
Protocols1 STM-1/OC-3, STM-4/OC-12,
STM-16/OC-48, GbE, 1G FC, 2G FC,
4G FC
Type of client ports SFP
1. SDH/SONET is supported but must not be used for clock synchronization.
SDH/SONET client equipment requires external clock synchronization.

Module and System Specification 181


10TCC-PCTN-4GUS+10G

This table provides a summary of the supported client SFPs. Please refer to the
specifications for the individual SFP type.

Table 243: Supported Client SFPs for all Variants


850 nm types SFP/2G1/850I/MM/LC
SFP/4GU/850I/MM/LC
1310 nm types SFP/HS/1310S/SM/LC
SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
SFP/4GU/1310S/SM/LC
CWDM types SFP/2G5U/CxxxxL/SM/LC
SFP/2G5U/CxxxxV/SM/LC
SFP/4GU/CxxxxL/SM/LC
SFP/4GU/CxxxxV/SM/LC
DWDM types SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx 
(C band only)
Electrical types SFP/GBE/ELECTRICAL/RJ45

The following table provides information about the network port for all variants.

Table 244: Network Port - General Information for all Variants


Number of network ports 1
Type of network port Tunable DWDM interface

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type LC
Fiber type SM 9 µm
Data rates 9.95328 Gbit/s, 10.7092 Gbit/s
Protocols STM-64, OC-192, OTU2
Tuning time (any channel to any < 45 s
ch.)
Tuning time cold start (any channel < 60 s
to any channel)
Max. shuttered output power -30 dBm
(dark tuning)

The following table provides information about the network port for the
10TCC-PCTN-4GUS+10G-LN#DC.

Table 245: Network Port - Optical Performance for


10TCC-PCTN-4GUS+10G-LN#DC
Transmitter output power range -3 dBm ... 0 dBm
Transmitter wavelength range 81 channels, 50 GHz spacing in C
band acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 60 pm
Min. extinction ratio 11 dB at 10.7092 Gbit/s
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range without -14 dBm ... -1 dBm
FEC

182 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 245: Network Port - Optical Performance for


10TCC-PCTN-4GUS+10G-LN#DC (Continued)
Receiver dynamic range for -16 dBm ... -1 dBm
operation with FEC
OPR measurement range -18 dBm ... 2 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range -300 ps/nm ... +300 ps/nm
Dispersion load range with 1 dB -500 ps/nm ... -300 ps/nm and 
OSNR penalty +300 ps/nm ... +500 ps/nm
Dispersion load range with 2 dB -700 ps/nm ... -500 ps/nm and 
OSNR penalty +500 ps/nm ... +700 ps/nm
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)
OSNR penalty at -16 dBm Rx input 1 dB
power without FEC
OSNR penalty at -18 dBm Rx input 1 dB
power with FEC

This table provides information about the bit error rate versus OSNR for
10TCC-PCTN-4GUS+10G-LN#DC.
Table 246: Bit Error Rate Versus OSNR for
10TCC-PCTN-4GUS+10G-LN#DC
Bit Error Ratio without FEC < 10-12 at 23 dB OSNR at 0.1 nm
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Pre-FEC Bit Error Ratio1 < 10-9 at 19 dB OSNR at 0.1 nm


< 10-5 at 15 dB OSNR at 0.1 nm
< 10-4 at 13 dB OSNR at 0.1 nm
< 10-3 at 12 dB OSNR at 0.1 nm
1. To achieve the specified Pre-Fec Bit error ratio at OSNR values below 13dB
the ATC may need up to 10 minutes for adjusting the threshold.

The following table provides information about the network port for the
10TCC-PCTN-4GUS+10G-V#DC.

Table 247: Network Port - Optical Performance for


10TCC-PCTN-4GUS+10G-V#DC
Transmitter output power range +4 dBm ... +6 dBm
Transmitter wavelength range 81 channels, 50 GHz spacing in C
band acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 60 pm
Min. extinction ratio 10 dB
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -20 dBm ... -8 dBm
OSNR penalty at -22 dBm input 1 dB
power
OPR measurement range -22 dBm ... -5 dBm

Module and System Specification 183


10TCC-PCTN-4GUS+10G

Table 247: Network Port - Optical Performance for


10TCC-PCTN-4GUS+10G-V#DC (Continued)
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range +200 ps/nm ... +900 ps/nm
Dispersion load range with 1 dB -150 ps/nm ... +200 ps/nm and 
OSNR penalty +900 ps/nm ... +1250 ps/nm
Dispersion load range with 2 dB -500 ps/nm ... -150 ps/nm and 
OSNR penalty +1250 ps/nm ... +1600 ps/nm
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)

This table provides information about the bit error rate versus OSNR for
10TCC-PCTN-4GUS+10G-V#DC.
Table 248: Bit Error Rate Versus OSNR for 10TCC-PCTN-4GUS+10G-V#DC
Pre-FEC Bit Error Ratio < 10-12 at 25 dB OSNR at 0.1 nm
< 10-9 at 23 dB OSNR at 0.1 nm
< 10-5 at 19 dB OSNR at 0.1 nm
< 10-4 at 17 dB OSNR at 0.1 nm
< 10-3 at 16 dB OSNR at 0.1 nm

The following table provides information about the network port for the
10TCC-PCTN-4GUS+10G-V#DL.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 249: Network Port - Optical Performance for
10TCC-PCTN-4GUS+10G-V#DL
Transmitter output power range +3 dBm ... +5 dBm
Transmitter wavelength range 41 channels, 100 GHz spacing in L
band acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 100 pm
Min. extinction ratio 10 dB
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -20 dBm ... -8 dBm
OSNR penalty at -22 dBm input 1 dB
power
OPR measurement range -22 dBm ... -5 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range +200 ps/nm ... +900 ps/nm
Dispersion load range with 1 dB -150 ps/nm ... +200 ps/nm and 
OSNR penalty +900 ps/nm ... +1250 ps/nm
Dispersion load range with 2 dB -500 ps/nm ... -150 ps/nm and 
OSNR penalty +1250 ps/nm ... +1600 ps/nm
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)

184 Module and System Specification


Chapter 3 Core Type Channel Modules

This table provides information about the bit error rate versus OSNR for
10TCC-PCTN-4GUS+10G-V#DL.

Table 250: Bit Error Rate Versus OSNR for 10TCC-PCTN-4GUS+10G-V#DL


Pre-FEC Bit Error Ratio < 10-12 at 25 dB OSNR at 0.1 nm
< 10-9 at 23 dB OSNR at 0.1 nm
< 10-5 at 19 dB OSNR at 0.1 nm
< 10-4 at 17 dB OSNR at 0.1 nm
< 10-3 at 16 dB OSNR at 0.1 nm

To achieve a post-FEC BER better than 10-12, ADVA Optical


Networking recommends operating the network port of the
PS

module at pre-FEC BER values not higher than stated in the


Note following table.

This table shows the recommended maximum pre-FEC bit error ratio for all
variants.

Table 251: Recommended Maximum Pre-FEC BER for all Variants


GFEC 1 x 10-5
EFEC-2 5 x 10-4
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

This table contains information about the multiplexing scheme for all variants.

Table 252: Multiplexing Scheme for all Variants


OTN/SONET STS3c-SPE - STS3c - STS192 -
OPU2 - ODU2 - OTU2 - OCh
OTN/SDH VC4 - AU4 - AUG1 - AUG64 - STM64 -
OPU2 - ODU2 - OTU2 - OCh
GFP GFP-T acc. to ITU-T G.7041
Max packet size: GbE:
9k (with no packet loss)
64k with possible packet loss

Module and System Specification 185


10TCC-PCTN-4GUS+10G

Table below provides information about the operation modes for all variants.

Table 253: Operation Modes for all Variants


Supported services All services supported on all ports.
A mix of services is supported.
The total capacity of the STM-64 signal is 64 x
VC4.
The required capacity per GFP-T service is: 1G FC:
6 x VC4
GbE: 7 x VC4
2G FC: 12 x VC4
4G FC: 24 x VC4
STM-1/OC-3: 2 x VC4
STM-4/OC-12: 5 x VC4
STM-16/OC-48: 18 x VC4
The total capacity of OC-192 signal is
64 x STS-3c.
The required capacity per GFP-T service is: 1G FC:
6 x STS-3c SPE
GbE: 7 x STS-3c SPE
2G FC: 12 x STS-3c SPE
4G FC: 24 x STS-3c SPE
STM-1/OC-3: 2 x STS-3c SPE
STM-4/OC-12: 5 x STS-3c SPE
STM-16/OC-48: 18 x STS-3c SPE

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table contains information about the system performance for all variants.
Table 254: System Performance for all Variants
Max. module delay for STM64: 47 µs
GbE OTU2: 48 µs without FEC, 54 µs with GFEC, 97 µs
with EFEC
Max. module delay for STM64: 53 µs
1G FC OTU2: 54 µs without FEC, 60 µs with GFEC, 105
µs with EFEC
Max. module delay for STM64: 36 µs
2G FC OTU2: 36 µs without FEC, 43 µs with GFEC, 86 µs
with EFEC
Max. module delay for STM64: 28 µs
4G FC OTU2: 28 µs without FEC, 35 µs with GFEC, 78 µs
with EFEC
Max. module delay for STM64: 124 µs
STM1/OC3 OTU2: 127 µs without FEC, 160 µs with GFEC,
210 µs with EFEC
Max. module delay for STM64: 72 µs
STM4/OC12 OTU2: 64 µs without FEC, 80 µs with GFEC, 110
µs with EFEC
Max. module delay for STM64: 40 µs
STM16/OC48 OTU2: 45 µs without FEC, 50 µs with GFEC, 90 µs
with EFEC
Max. differential VCAT 122.5 µs
delay

186 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 254: System Performance for all Variants (Continued)


Number of 15 using 2WCC-PCN-10G as bidirectional single
regenerators1 module N-N regenerator (OTU2 with EFEC-2
only)
7 using 2WCC-PCN-10G as bidirectional single
module C-N regenerator (no FEC or GFEC on
client ports only)
3 using WCC-PCTN-10G as back-to-back
regenerator
3 using 2WCA-PCN-10G (FEC bypass, C band,
ALS disabled) as bidirectional single module C-N
regenerator.
Number of back-to-back 7 for GbE, 1G FC, 2G FC and 4G FC using
cascades (without 10TCC-PCTN-4GUS+10G
protection capability) 3 for STM-1, STM-4 and STM-16 using
10TCC-PCTN-4GUS+10G
1. Only one regeneration is allowed for SDH / SONET services.

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

This table shows information about fault monitoring of the module in general for
all variants.

Table 255: Fault Monitoring - General for all Variants


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Capability Level mismatch;
Client port SFP missing;
Client port SFP mismatch;

This table shows information about fault monitoring of the client ports in general
for all variants.

Table 256: Fault Monitoring Client Interface General for all Variants
Physical layer Laser failure;
Laser degrade (based on bias
current);
Loss of signal (LOS)

Module and System Specification 187


10TCC-PCTN-4GUS+10G

This table shows information about fault monitoring of the client ports in ingress
direction for all variants.

Table 257: Fault Monitoring Client Interface - Ingress Direction for all
Variants
Physical coding sublayer (PCS) Loss of character synchronization 
(not supported for STM-1/OC-3,
STM-4/OC-12, STM-16/OC-48
services)

This table shows information about fault monitoring of the network ports for all
variants.

Table 258: Fault Monitoring Network Interface - General for all Variants
Physical layer Laser failure;
Receiver clock synch failure;
Loss of signal (LOS)

This table provides information about fault monitoring of the network ports for all
variants.

Table 259: Fault Monitoring Network Interface - Egress Direction for all
Variants
STM-64 RS/OC-192 section layer LOF

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
STM-64 MS/OC-192 line layer AIS, RDI, SD
VC-4/STS3c-SPE layer AIS, LOP, RDI, PLM, UNEQ
OCH/OTU2 layer LOF, LOM, AIS
OTU2 layer - SM byte BDI, SD, TIM
ODU2 layer - PM byte AIS, BDI, OCI, LCK, SD, TIM
ODU2 layer -TCMi byte, i = 1...6 AIS, BDI, OCI, LCK, LTC, SD, TIM
OPU2 layer AIS, PLM
GFP common LOF, PLM, SSF
GFP-T Loss of client signal far end (10B_ERR,
CMF UPI)
Loss of character synchronization far
end (CMF UPI)

188 Module and System Specification


Chapter 3 Core Type Channel Modules

The following table provides information about performance monitoring of the


module in general for all variants.

Table 260: Performance Monitoring - General for all Variants


Equipment Module temperature
(Fix threshold crossing alert for module (current value)
temperature too high available)

This table shows information about performance monitoring of the client ports for
all variants.

Table 261: Performance Monitoring Client Interface - General for all Variants
Physical layer Transmitter bias current
(15 min/24 h records available for PM values (current); Optical power
except current values; user configurable Rx (current, low, mean,
threshold crossing alerts for OPR too high/too high); Optical power Tx
low available; fix threshold crossing alerts for (current, low, mean,
OPT too high/too low available) high)1
1. Transmitter bias current, optical power Rx and optical power Tx are not
supported for electrical SFPs.

The following table gives information about performance monitoring of the client
ports in ingress direction for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 262: Performance Monitoring Client Interface - Ingress Direction for all
Variants
Ethernet PM Rx Received frames, Pause frames,
Bad frames (CRC), Received
bytes
Ethernet PM Tx Transmitted frames, Pause
frames, Bad frames (CRC),
Transmitted bytes
Physical coding sublayer (PCS) ES; CV; DE1 (not supported for
STM-1/OC-3, STM-4/OC-12,
STM-16/OC-48 services)
1. DE counter is not supported for electrical SFPs.

This table shows information about performance monitoring of the network ports
for all variants.

Table 263: Performance Monitoring Network Interface - General for all


Variants
Physical layer Optical power Rx
(15 min/24 h records available for PM values (current, low, mean,
except current values; user configurable high);
threshold crossing alerts for OPR too high/too low Optical power Tx
available; (current, low, mean,
fix threshold crossing alerts for OPT too high/too high)
low available)

Module and System Specification 189


10TCC-PCTN-4GUS+10G

The following table gives information about performance monitoring of the


network ports in egress direction for all variants.

Table 264: Performance Monitoring Network Interface - Egress Direction for


all Variants
STM-64 RS/OC-192 section layer ES; SES; OOFS/SEFS; BBE/CV
(15 min/24 h records with user configurable
threshold crossing alerts available)
STM-64 RS/OC-192 section layer ES; SES; UAS; BBE/CV
(15 min/24 h records with user configurable
threshold crossing alerts available)
OCH/OTU2 layer CE; UBE; ES; SES
(15 min/24 h records with user configurable
threshold crossing alerts available)
OTU2 layer - SM byte ES; SES; UAS; BBE
(15 min/24 h records with user configurable
threshold crossing alerts available)
OTU2 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user configurable
threshold crossing alerts available)
ODU2 layer - TCMi byte, i = 1 ... 6 ES; SES; UAS; BBE
(15 min/24 h records with user configurable
threshold crossing alerts available)
GFP common Good GFP frames;

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
(15 min/24 h records available) Discarded GFP frames due to
cHEC errors;
Discarded GFP frames due to
tHEC errors
GFP-T (15 min/24 h records available) Discarded superblocks due to
CRC errors

This table provides information about the loop functionality for all variants.

Table 265: Loop Functionality for all Variants


Client ports Facility loop on individual port,
Terminal loop on individual port
Network port Facility loop, Terminal loop

This table shows information about protection setting for all variants.

Table 266: Protection Switching for all Variants


Protection scheme Channel card protection 
(not supported if an electrical SFP is
provisioned)
Protection switching time < 50 ms
Switching criteria: LOS, Receiver clock synch failure,
OTU2 on network port OTU2-LOF, OTU2-LOM, OTU2-AIS,
ODU2-AIS, ODU2-OCI, ODU2-LCK,
ODU2-PM-SD (optional)

190 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 266: Protection Switching for all Variants (Continued)


Switching criteria: LOS, Receiver clock synch failure,
SDH/SONET on network port LOF, MS-AIS, MS-SD (optional)
Restoration scheme Versatile switched protection,
The module must not be configured to
channel card protection.
(RSM-SF, RSM-OLM, VSM)
Restoration time < 10 s

This table contains information about the ECC for all variants.

Table 267: Embedded Control Channel (ECC) for all Variants


Notice: One GCC or DCC channel is supported per port
Client ports none
Network port GCC0 (1312 kbit/s), GCC0S (82 kbit/s)
GCC1 (1312 kbit/s), GCC2 (1312 kbit/s)
DCCr/SDCC (STM64/OC192; 192 kbit/s)
DCCm/LDCC (STM64/OC192; 576
kbit/s)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 191


10TCC-PCN-2G7US+10G

10TCC-PCN-2G7US+10G
The 10TCC-PCN-2G7US+10G is a 10-port 10G Add Drop Multiplexer (ADM)
module that can be configured to provide a single ADM function within an ADM
network of modules. The ADM function provides up to 10 interfaces for client
signals to be added and dropped or passed through and transported over the
ADM network (which is a subnetwork of the core optical network). The client
interfaces are customer-facing and the network interfaces are network-facing.
Since the client interfaces are lower rate services (lower than 10 Gbit/s), the
module cannot be used as a regenerator.
This module can transport up to ten GbE services (including synchronous GbE),
STM1/OC3, STM4/OC12, or up to eight STM-16/OC-48 and OTU1 services with
two network interfaces configured. Any Client service can be routed to either of
the Network interfaces. An OTU1 client service can be terminated at the OPU
layer, and up to two ODU0s can be de-multiplexed and routed individually. One
or both of the ODU0s de-multiplexed from a client OTU1 service can be routed
to another Client interface and the mapped GbE service can be add/dropped
(Local C-to-C service).
The module supports path protection and Client Channel Card Protection
(CCCP). Performance monitoring and fault management of physical layer
alarms and service-related alarms are also supported.
Table 268 provides general information about the module and the environment.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 268: Module - General Information
Equipment type 10TCC10G
First release 11.1
MTBF at 25°C ambient 194,214 h
temperature
Typ. power consumption 80 W
(incl. SFPs)
Max. power consumption 100 W
(incl. SFPs)
Width 8 HP
Height 5 HU
Weight (incl. SFPs) 1.3 kg
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according IP20. Use in a pollution degree 2
to IEC 60529 environment and indoor controlled office
environments only.
Slot positions SH9HU: 3...17
SH7HU, SH7HU-R: 3...171
SH1HU-HP/2DC, SH1HU-R/PF and
SH1HU-HP/E-TEMP/2DC: 1
NCU types NCU-II, NCU-II-P

192 Module and System Specification


Chapter 3 Core Type Channel Modules

1. If redundant 400 W power supplies are installed in a 7HU shelf a maximum


of three 10TCC-PCN-2G7US+10G modules can be deployed.
If redundant 600 W power supplies are installed in a 7HU shelf a maximum
of five 10TCC-PCN-2G7US+10G modules can be deployed.

Table 269 provides information about the client ports.

Table 269: Client Ports - Specifications


Number of client ports 10
Data rates 155.52 Mbit/s, 622.08 Mbit/s,
1.250 Gbit/s, 2.48832 Gbit/s,
2.666 Gbit/s
Protocols GbE, STM-1, STM-4, STM-16, OC-3,
OC-12, OC-48, OTU1
Type of client ports SFP

Table 271 provides information about jitter and wander compliance.

Table 270: Jitter and Wander Compliance


Jitter and wander GbE according to IEEE802.3 and G.8262 for
compliance for transparent transport of SyncE
GbE compliant for transparent transport of
1588v2 PTP frequency synchronization acc to
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

G.8265
STM-n according to G.783 and G.813

Table 271 provides a summary of the supported client SFPs. Please refer to the
specifications for the individual SFP type.

Table 271: Supported Client SFPs


850 nm types SFP/2G1/850I/MM/LC
SFP/GBE/850I/MM/LC/TIN
SFP/HS/850I/MM/LC
1310 nm types SFP/GBE/1310S/SM/LC/TIN
SFP/GBE/1310L/SM/LC/TIN
SFP/CL/1310I/SM/LC
SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
SFP/HS/1310S/SM/LC
1550 nm types SFP/GBE/1550V/SM/LC/TIN
CWDM types SFP/2G5U/CxxxxL/SM/LC
SFP/2G5U/CxxxxV/SM/LC
DWDM types SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx

Module and System Specification 193


10TCC-PCN-2G7US+10G

Table 272 provides information about the network ports.

Table 272: Network Ports - Specifications


Number of network ports 2
Data rates 10.7092 Gbit/s
Protocols OTU2
Type of network ports XFP

Table 273 provides a summary of the supported network XFPs. Please refer to
the specifications for the individual XFP type.

Table 273: Supported Network XFPs


1310 nm types XFP/11G/1310S/SM/LC
XFP/10G/1310S/SM/LC
1550 nm types XFP/11G/1550L/SM/LC
XFP/10G/1550L/SM/LC
CWDM types XFP/11G/CxxxxL/SM/LC
XFP/11G/CxxxxV/SM/LC
DWDM types XFP/11G/#19xxxL50/SM/LC
XFP/11G/Dxxxx.xxV/SM/LC
XFP/11G/DCTLNR/SM/LC
XFP/11G/DCTLN/SM/LC
XFP/11G/DCTV/SM/LC

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 274 provides information about the recommended maximum pre-FEC bit
error ratio.

Table 274: Recommended Maximum Pre-FEC BER


GFEC 1 x 10-5
EFEC-2 5 x 10-4

Table 275 provides information about mapping, termination, and multiplexing


schemes.

Table 275: Mapping, Termination, and Multiplexing Schemes


Mapping Protocols STM-1/OC3 and STM-4/OC12 signals
are GMP mapped into an ODU0
GbE signals are TTT encoded and
then GMP mapped into OPU0/ODU0;
STM-16 and OC-48 signals are BMP
mapped into ODU1

194 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 275: Mapping, Termination, and Multiplexing Schemes


Termination of OTU1 Client OTU1 signals can be terminated at the
Services ODU layer on the client port and the
resulting ODU1 transported
transparently
OTU1 signals can be terminated at the
OPU layer on the client port and up to
two ODU0s are de-multiplexed and
transported separately
Multiplexing LO ODU into OPU2 Up to four ODU1s can be multiplexed
into one OPU2; each ODU1 is
multiplexed into two OPU2 tributary
slots via ODTU12 as defined in G.709
Up to eight ODU0s can be multiplexed
into one OPU2; each ODU0 is
multiplexed into an OPU2 tributary slot
via ODTU2.1 as defined in G.709

Table 276 provides information about the system performance.

Table 276: System Performance


Max. module delay for No FEC = 80 µs
1GbE GFEC = 90 µs
EFEC-2 = 130 µs
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Max module delay for No FEC = 190 µs


STM-1/OC-3 GFEC = 200 µs
EFEC-2 = 240 µs
Max module delay for No FEC = 60 µs
STM-4/OC-12 GFEC = 70 µs
EFEC-2 = 120 µs
Max. module delay for No FEC = 60 µs
STM-16/OC-48 GFEC = 70 µs
EFEC-2 = 110 µs
Max. module delay for No FEC = 80 µs
OTU1 GFEC = 90 µs
EFEC-2 = 130 µs
Number of regenerators 15 using 2WCC-PCN-10G as bidirectional
single module N-N regenerator (OTU2 with
EFEC-2 only)
7 using 2WCC-PCN-10G as bidirectional
single module C-N regenerator (no FEC or
GFEC on client ports only)
3 using WCC-PCTN-10G as back-to-back
regenerator (SDH/SONET/OTN only).
Max. number of modules in 30
Add Drop configurations
Max. Ethernet frame size 9612 bytes

Module and System Specification 195


10TCC-PCN-2G7US+10G

Whether fault/performance monitoring entries listed in the

PS
following tables are applicable for a specific deployment depends
on the configuration of the respective interface.
Note

Table 277 provides information about fault monitoring of the module in general.

Table 277: Fault Monitoring - Module


Equipment Module removed;
Equipment mismatch;
Module voltage out of range;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Capability Level mismatch

Table 278 provides information about fault monitoring of the client ports for the
physical layer.

Table 278: Fault Monitoring Client Interface Physical Layer


Physical layer Laser failure; Loss of signal (LOS);
Rx clk sync failure; Plug rate not
supported

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 279 provides information about fault monitoring of the client ports in
ingress direction.

Table 279: Fault Monitoring Client Interface [CH] - Ingress Direction


Physical coding sublayer  Loss of character synchronization
(GbE PCS) (near end)
STM-16 RS/OC-48 section layer LOF; TIM
STM-16 MS/OC-48 line layer SD-L, AIS-L, RDI-L
OCH/OTU1 layer LOF; LOM; AIS
OTU layer - SM byte TIM; SD; BDI
ODU layer - PM byte TIM; SD; BDI; AIS; OCI, LCK
TCMODU layer TCMi byte, i = 1...6 TIM; SD; BDI; AIS; OCI; LCK; LTC
OPU layer AIS; PLM

Table 280 provides information about the Client VCH alarms.

Table 280: Fault Monitoring Client ODU [VCH] with mapped Client signal
(STM1/OC3, STM4/OC12, STM16/OC48, GbE)
ODU layer - PM byte AIS, OCI, LCK, BDI, TIM
OPU layer CSF, AIS, PLM
GFP LOF, PLM, LOSFWD, CHARSYNC-FEND

196 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 281 provides information about the Client VCH1 alarms.

Table 281: Fault Monitoring Client De-multiplexed ODU0 [VCH1]


(de-multiplexed from a Client OTU1)
ODU Layer - PM byte TIM, SD, BDI, AIS, OCI, LCK, ODU-TRIB-MISM
ODU Layer - TCMi byte,  TIM, SD, BDI, AIS, OCI, LCK, LTC
i = 1...6

Table 282 provides information about fault monitoring of the network ports for
the physical layer.

Table 282: Fault Monitoring Network Interface - Physical Layer


Physical layer Laser failure;
Loss of signal (LOS);
Rx clk sync failure; Plug rate not supported
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 197


10TCC-PCN-2G7US+10G

Table 283 provides information about fault monitoring of the network ports for
the data layer in egress direction.

Table 283: Fault Monitoring Network Interface [CH] - Egress Direction


OCH/OTU2 layer LOF, LOM
OTU2 layer - SM byte AIS, BDI, SD, TIM
ODU2 layer - PM byte AIS, BDI, OCI, LCK, SD, TIM
ODU2 layer -TCMi byte, i = 1...6 AIS, BDI, OCI, LCK, LTC, SD, TIM
OPU2 layer AIS, PLM

Table 284 provides information about fault monitoring of the network ports for the
data layer from Network OTU2.

Table 284: Fault Monitoring Network De-Multiplexed ODU [VCH1] from


Network OTU2
ODU layer - PM byte LOF, LOM, AIS, BDI, OCI, LCK, SD, TIM
ODU - TCMi byte; i = 1 .. 6 AIS, BDI, OCI, LCK, SD, TIM, LTC,
ODU-TRIB-MISM

Table 285 provides information about performance monitoring of the module in


general.

Table 285: Performance Monitoring - Module

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Equipment Module temperature (current value)
(Fix threshold crossing alert for module
temperature too high available)

Table 286 provides information about performance monitoring of the client ports
for the physical layer.

Table 286: Performance Monitoring Client Interface - Physical Layer


Physical layer Laser bias current
(15 min/24 h records available for PM values (current); Optical power
except current values; user configurable Rx (current, low, mean,
threshold crossing alerts for OPR too high/too high); Optical power Tx
low available; Fix threshold crossing alerts for (current, low, mean,
OPT too high/too low available) high)
User configurable threshold crossing alerts for
OPR and OPT too high/too low available)

198 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 287 provides information about performance monitoring of the client ports
in ingress direction.

Table 287: Performance Monitoring Client Interface - Data Layer


Physical coding sublayer GbE (near end)
(15 min/24 h records available) ES, DE, CV
Ethernet Layer Rx Direction
- Frames Received (FRRCV)
- PAUSE Frames Received
(PSFRRCV)
- CRC-errored Frames Received
(CRCFRRCV)
- Bytes Received (BYTERCV)
Tx Direction
- Frames Transmitted (FRTRMT)
- PAUSE Frames Transmitted
(PSFRTRMT)
- CRC-errored Frames Egress
(CRCFREGRS)
- Bytes Transmitted (BYTETRMT)
STM-16 RS/OC-48 - RS/ Section layer ES; SES; SEFS; CV
(15 min/24 h records with user
configurable threshold crossing alerts
available)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

STM-16 RS/OC-48 - MS/Line layer ES; SES; UAS; CV


(15 min/24 h records with user
configurable threshold crossing alerts
available)
OCH/OTU(OTU FEC) layer CE; UBE; BERCE
(15 min/24 h records with user
configurable threshold available for CE,
UBE if FEC is enabled)
OTU layer ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold available)
ODU layer ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold available)
TCM layer ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold available)

Table 288 provides information about the LO-ODU0 (de-multiplexed from a


client OTU1 service) for the Client Port.

Table 288: Performance Monitoring Client De-multiplexed ODU0 [VCH1]


from Client OTU1
ODU Layer ES, SES, BBE, UAS
TCMi Layer ES, SES, BBE, UAS

Module and System Specification 199


10TCC-PCN-2G7US+10G

Table 289 provides information about performance monitoring of the network


ports.

Table 289: Performance Monitoring Network Interface - Physical Layer


Physical layer Laser bias current
(15 min/24 h records available for PM values (current); Optical power
except current values; user configurable Rx (current, low, mean,
threshold crossing alerts for OPR too high/too low high); Optical power Tx
available) (current, low, mean,
high)

Table 290 provides information about performance monitoring of the network


ports for the data layer.

Table 290: Performance Monitoring Network Interface [CH] - Data Layer


OCH/ OTU (OTU FEC) layer PMs CE; UBE; BERCE
(15 min/24 h records available for CE, UBE if FEC
is enabled)
OTU layer PMs ES, SES; BBE; UAS
(15 min/24 h records with user configurable
threshold available)
ODU layer PMs ES; SES; BBE; UAS
(15 min/24 h records with user configurable

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
threshold available)
TCM layer PMs ES; SES; BBE; UAS
(15 min/24 h records with user configurable
threshold available)

Table 291 provides information about performance monitoring of the network


ports for the data layer.

Table 291: Performance Monitoring Network De-multiplexed ODU [VCH1]


from Network OTU2
ODU layer PMs ES; SES; BBE; UAS
TCM layer PMs ES; SES; BBE; UAS

Table 292 provides information about the loop functionality.

Table 292: Loop Functionality


Client ports Facility loop, Terminal loop
Network port Facility loop, Terminal loop

Table 293 provides information about protection switching.

Table 293: Protection Switching


Protection scheme Path protection;
Client Channel Card Protection (CCCP)
Protection switching time < 50 ms

200 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 293: Protection Switching (Continued)


Switching criteria:
ODTU SSF (due to PHY layer LOS and LOC
and OTU layer LOF, LOM, or AIS),
LOF/LOM, TRIB-MISM
ODU AIS, LCK, OCI
OPU PLM, CSF, AIS
Client PHY Plug Removed (applies to CCCP only)
Restoration scheme Versatile switched protection
(RSM-SF, RSM-OLM, VSM)
Restoration time < 10 s

Table 294 provides information about the ECC.

Table 294: Embedded Control Channel (ECC)


Notice: One GCC channel is supported per port
Client ports GCC0S (82 kbit/s), GCC0 (326 kbit/s),
GCC1 (326 kbit/s), GCC2 (326 kbit/s)
SDCC (192 kbit/s)
Network ports GCC0S (82 kbit/s), GCC0 (1312 kbit/s), 
GCC1 (1312 kbit/s), GCC2 (1312 kbit/s)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 201


10WXC-PCN-10G

10WXC-PCN-10G
The 10WXC-PCN-10G is an ODU switching module providing 10x 10G ports for
a combined switching capability of 100Gbps.
Each 10 x 10G port supports service types of OTU2, OTU2e, STM-64/OC-192,
10GBE WAN, and 10GBE LAN. The STM-64/OC-192, 10GBE WAN, and
10GBE LAN service types are mapped into ODU2 or ODU2e for switching.
OTU2e services may be switched as an ODU2e and/or demapped back to
10GBE LAN.
OTU2 services are either switched as ODU2 and/or demapped back to
STM-64/OC-192, 10GBE WAN or demultiplexed to component ODU1s or
ODU0s which are space and time switched to another port where the
component ODU1s and ODU0s are multiplexed back into an OTU2.
All 10G ports accept a range of XFP MSA compliant pluggable transceivers.
The 10WXC-PCN-10G is capable of operating as a stand-alone module
interfacing to other FSP 3000R7 10G modules or to third party equipment.
Table 295 contains general information about the module and its environment.

Table 295: General Information


Equipment type 10WXC10G
First release 12.1
Width 8 HP

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Height 5 HU
Weight approx. 1.5 kg (3.500 lbs)
Environmental conditions1 Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 140,887 h
Typ. power consumption 165 W
Max. power consumption 185 W
Max power consumption in 175 W
stand-alone applications
Slot positions SH9HU: 3...17
NCU types NCU-II, NCU-II-P
1. If the module is operated in the 9HU shelf, the fan speed will automatically be
increased to generate greater airflow.

Table 296 provides information about the optical ports.

Table 296: Optical Port - Specifications


Number of ports 10
Optical connector type LC
Fiber Type SM 9 µm
Type of optical port XFP Pluggable

202 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 296: Optical Port - Specifications


Data rates 9.9532 Gbit/s (STM-64)
9.9532 Gbit/s (OC-192)
9.9532 Gbit/s (10GbE WAN)
10.3125 Gbit/s (10GE LAN)
10.7092 Gbit/s (OTU2)
11.0957 Gbit/s (OTU2e)
Protocols STM-64, OC-192, 10 GbE WAN, 10
GbE LAN, OTU2, OTU2e

Table 297 provides information about jitter and wander compliance.

Table 297: Jitter and Wander Compliance


Jitter and wander GbE according to IEEE802.3 and G.8262 for
compliance for transparent transport of SyncE
GbE compliant for transparent transport of
1588v2 PTP frequency synchronization acc to
G.8265
STM-n according to G.783 and G.813
OC-192 according to Telcordia GR-253

Table 298 provides a summary of the supported XFP transceivers.

Table 298: Supported XFPs


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

850 nm types XFP/10G/850I/MM/LC (HW Rev. 1.01 or newer, for data


rates up to 10.519 Gbit/s)
1310 nm types XFP/11G/1310S/SM/LC (HW Rev. 3.01 or newer, for data
rates up to 11.317 Gbit/s)
XFP/10G/1310S/SM/LC (for data rates up to
10.709 Gbit/s)
1550 nm types XFP/11G/1550L/SM/LC (HW Rev. 2.00 or newer, for data
rates up to 11.317 Gbit/s)
XFP/10G/1550L/SM/LC (for data rates up to 10.709Gbit/s)
CWDM types XFP/11G/CxxxxL/SM/LC (HW Rev. 2.00 or newer, for data
rates up to 11.317 Gbit/s)
XFP/11G/CxxxxV/SM/LC (HW Rev. 2.00 or newer, for data
rates up to 11.317 Gbit/s)
DWDM types XFP/11G/Dxxxx.xxV/SM/LC#Dxx (for data rates up to
11.317 Gbit/s)
XFP/11G/DCTV/SM/LC (for data rates up to
11.3176 Gbit/s)
XFP/11G/DCTLNR/SM/LC (HW Rev 1.01 or newer, for
data rates up to 11.317 Gbit/s)
XFP/11G/DCTLN/SM/LC (HW Rev 1.01 or newer, for data
rates up to 11.317 Gbit/s)

Module and System Specification 203


10WXC-PCN-10G

Table 299 provides information about the system performance.

Table 299: System Performance


Transit delay per port
No FEC GFEC EFEC-2
ODU0 40 ... 60 µs 50 ... 55 µs 90 ... 95 µs
ODU1 23 ... 28 µs 30 ... 35 µs 70 ... 75 µs
ODU2 10 ... 15 µs 17 ... 22 µs 60 ... 65 µs
ODU2e 10 ... 15 µs 17 ... 22 µs 60 ... 65 µs
10GbE LAN 25 µs NA NA
10GbE WAN 25 µs NA NA
STM-64 25 µs NA NA
OC-192 25 µs NA NA

Table 300 the recommended maximum pre-FEC bit error ratio for the traffic
ports.

Table 300: Recommended Maximum Pre-FEC BER


GFEC 1 x 10-5
EFEC- 2 5 x 10-4

Table 301 provides information about the mapping and multiplexing schemes.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 301: Multiplexing and Mapping Schemes
OTN multiplexing
Mapping OTU2/ODU2
Mapping OTU2e/ODU2e
Multiplexing OTU2/ODU2/OPU2/ODTUG2/(4x)ODTU12/ODU1 (4x ODU1)
Multiplexing OTU2/ODU2/OPU2/ODTUG2/(8x)ODTU2.1/ODU0 (8x ODU0)
Non-blocking cross-connect of ODU2 between any ports
Non-blocking cross-connect of ODU2e between any ports
Non-blocking cross-connect of ODU1 between any ports
Non-blocking cross-connect of ODU0 between any ports
Multiplexing into ODU2: any combination of supported ODUs on the same
ODU2
Multiplexing into ODU2: supported ODUs multiplexed into any tributary slot
OTN mapping
Bit synchronous mapping of 10G LAN into OPU2e
Bit synchronous mapping of 10G WAN into OPU2
Bit synchronous mapping of STM-64 into OPU2
Bit synchronous mapping of OC-192 into OPU2

204 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 302 provides information about Synchronization and Timing.

Table 302: Synchronization and Timing


Traffic Ports
Timing source OTU2 when internal timing
cross-connecting ODU1/0
Timing source OTU2 when derived from corresponding incoming
cross-connecting ODU2: OTU2. When LOS/LOC: internal timing
Timing source OTU2e when derived from corresponding incoming
cross-connecting ODU2e OTU2e. When LOS/LOC: internal timing
Timing source OTU2e when internal timing
mapping clients into ODU2e
Timing source when traffic test derived from corresponding incoming port
loop (facility/terminal) is activated
Timing source when LOS/LOC internal timing
Timing source 10G LAN internal clock
Timing source 10G WAN derived from ODU2 demapped 10GE
WAN or from corresponding incoming
10G WAN port
Timing source OTU2 when derived from corresponding incoming
mapping STM-64/OC-192/10G client signal
WAN clients into ODU2
Timing source STM-64 derived from ODU2 demapped STM-64
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

or from corresponding incoming STM-64


port
Timing source OC192 derived from ODU2 demapped OC-192 or
from corresponding incoming OC-192
port
Internal OTU2 clock accuracy +/-20ppm
Internal OTU2e clock accuracy +/-20ppm
Internal 10G LAN clock accuracy +/-100ppm
Internal 10G WAN clock accuracy +/-20ppm
Internal STM-64 clock accuracy +/-20ppm
Internal OC-192 clock accuracy +/-20ppm
SDH/SONET timing and synchronzation (SETS)
Timing marker (S1) untouched
ITU-T G.8261 Ethernet Synchronzation (SyncE)
10G LAN transparent for SyncE
IEEE 1588v2 Precision Time Protocol (PTP)
10G LAN transparent for PTP
Real time clock
Real time clock ticks received from NCU; if not, default is free-running

Module and System Specification 205


10WXC-PCN-10G

Whether fault/performance monitoring entries listed in the

PS
following tables are applicable for a specific deployment depends
on the configuration of the respective interface.
Note

Table 303 provides information about fault monitoring on the module equipment
level in general.OK

Table 303: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
XFP not approved;
XFP missing;
XFP voltage alarm;

Table 304 provides information about fault monitoring of the traffic interfaces in
general. OK

Table 304: Fault Monitoring Traffic Interfaces - General

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Physical layer Laser failure
Laser degrade (based on bias current)
Receiver clock synch failure (RCVCLK)
Loss of signal (LOS)

Table 305 provides information about fault monitoring of the Rx Traffic


Interfaces.

Table 305: Fault Monitoring Rx Traffic Interfaces


OCH/OTU2/2e layer LOF, LOM, AIS
OTU2/2e layer - SM byte BDI, SD, TIM
ODU2/2e layer - TCMi byte, i=1..6 AIS, BDI, OCI, LCK, LTC, SD, TIM
ODU2/2e layer - PM byte AIS, BDI, OCI, LCK, SD, TIM
OPU2/2e layer AIS, PLM, CSF
ODU1 - PM byte AIS, BDI, OCI, LCK, SD, TIM, MSIM,
LOFLOM
ODU0 - PM byte AIS, BDI, OCI, LCK, SD, TIM, MSIM,
LOFLOM
10GBE LAN Physical Coding HIBER; Local Fault; Loss of
Sublayer Character synchronization
10GBE WAN section Layer LOF-S, TIM-S
10GBE WAN line layer AIS-L, RDI-L, SD-L
STM-64 RS/OC-192 section layer LOF-S; TIM-S
STM-64 MS/OC-192 line layer AIS-L, RDI-L, SD-L

206 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 306 provides information about performance monitoring of the module in


general.

Table 306: Performance Monitoring - General


Equipment Module temperature (current)
(Fix threshold crossing alert for module
temperature too high)
XFP XFP temperature (current)
(Fix threshold crossing alert for XFP
temperature too high or too low)

Table 307 provides information about performance monitoring of the traffic


interfaces.
Table 307: Performance Monitoring Traffic Ports
Physical layer (15 min/24 h records available Transmitter bias current
for PM values except current values; user (current);
configurable threshold crossing alerts for OPR Optical power Rx (current,
too high/too low available; fix threshold low, mean, high);
crossing alerts for OPT too high/too low Optical power Tx (current,
available) low, mean, high)
OCH/OTU2/2E layer (15 min/24 h records with CE, UBE, BERCE
user configurable threshold for CE and UBE)
ODU2/2E - TCMi byte, i=1..6 (15 min/ 24 h ES; SES; UAS; BBE
records with user configurable threshold)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

ODU2 layer - PM byte (15 min/ 24 h records ES; SES; UAS; BBE
with user configurable threshold)
ODU2 layer - PM byte (15 min/ 24 h records ES; SES; UAS; BBE
with user configurable threshold)
ODU1 layer - PM byte (15 min/ 24 h records ES; SES; UAS; BBE
with user configurable threshold)
ODU0 layer - PM byte (15 min/ 24 h records ES; SES; UAS; BBE
with user configurable threshold)
10GBE LAN - Physical Coding Sublayer ES, CV, SE
10GBE LAN Ethernet Rx Framed Statistics Good Frames; Pause
(15 min/24h records) Frames; CRC Frames;
Bytes
10GBE LAN Ethernet Tx Framed Statistics Good Frames, Pause
(15 min/24 h records) Frames, CRC Frames,
Bytes
10GBE WAN section layer (15 min/24 h ES, SES, SEFS/OOFS,
recored with user configurable threshold CV/BBE
crossing)
10GBE WAN line layer (15 min/24 h recored ES, SES, UAS, CV/BBE
with user configurable threshold crossing)
STM-64/OC192 section layer (15 min/24 h ES, SES, SEFS/OOFS,
recored with user configurable threshold CV/BBE
crossing)
STM-64/OC192 line layer (15 min/24 h recored ES, SES, UAS, CV/BBE
with user configurable threshold crossing)

Module and System Specification 207


10WXC-PCN-10G

Table 308 provides information about provides information about the ECC.

Table 308: Embedded Control Channel (ECC)


ECC on OTU2 GCC0, (1312 kbit/s) on each traffic port
ECC on OTU2e GCC0 (1360 kbit/s) on each traffic port
ECC on ODU2 GCC1, GCC2 (1312 kbit/s) on each traffic port
ECC on ODU2e GCC1, GCC2 (1360 kbit/s) on each traffic port
ECC on STM-64, DCCr/ SDCC (192 kbit/s) on each traffic port
OC-192,
10GBE WAN

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

208 Module and System Specification


Chapter 3 Core Type Channel Modules

2WCC-PCN-10G
The 2WCC-PCN-10G channel module is a 10G dual core channel module with
two XFP type pluggable client interfaces and two XFP type pluggable network
interfaces.
The 2WCC-PCN-10G is intended for transport of STM-64, OC-192, 8G FC, 
10 GbE, OTU2, OTU1e, and OTU2e services.
All applications can be transmitted natively. STM-64, OC-192, 8G FC, and 10
GbE services can be mapped into an OTU2 signal. 10 GbE services can also be
mapped into an OTU1e signal or an OTU2e signal. OTU2, OTU1e, and OTU2e
services cannot be mapped. GFEC can be enabled for OTU2, OTU1e and
OTU2e services at both the client port and the network port. EFEC with higher
coding gain is only supported on the network port.
The module provides performance monitoring data at the client port as well as at
the network port for the physical layer and the SDH/SONET or the OTN layer.
Other levels of PMs like PCS and Packet are also supported.
All optical interfaces utilize XFP pluggable optics. Therefore, if only a single
transponder function is desired, then only one Client interface and one Network
interface needs to be populated with XFPs. The XFP pluggable optics provides
the optical-to-electrical conversion (and vice versa) and collection of all PHY
(Physical) Layer PMs for each interface. It also provides the Loss Of Signal
(LOS) alarm monitoring.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

The following table contains general information about the module and their
environment.

Table 309: Module - General Information


Equipment type 2WCC10G
First release 10.2
MTBF at 25°C ambient temperature 301,306 h
Typ. power consumption (incl. XFP) 40 W
Max. power consumption (incl. XFP) 45 W
Maximum RAM consumption on NCU 571 Kbytes
Width 4 HP
Height 5 HU
Weight (incl. XFP) 876 g (1.9 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Slot positions SH9HU: 3...18
SH7HU/SH7HU-R: 3...18
SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P

Module and System Specification 209


2WCC-PCN-10G

This table provides information about the client ports.

Table 310: Client Port - Specifications


Number of client ports 2
Optical connector type LC
Fiber Type SM 9 µm
Type of client port XFP Pluggable
Data rates 8.5 Gbit/s, 9.9532 Gbit/s, 
10.3125 Gbit/s, 10.7092 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s
Protocols 8G FC, STM-64, OC-192, 10 GbE
LAN PHY, 10 GbE WAN PHY1,
OTU2, OTU1e (OTU2LAN without
stuffing), OTU2e (OTU2LAN with
stuffing), ITU-T G.8262 and IEEE
1588v2 compliant transparent
Ethernet transport
1. STM-64 or OC-192 facility type has to be selected on the corresponding port
in the system management.

The following table provides a summary of the supported client port XFPs.

Table 311: Supported Client XFPs

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
850 nm types XFP/10G/850I/MM/LC (HW Rev. 1.01 or newer)
XFP/8G/850I/MM/LC
1310 nm types XFP/11G/1310S/SM/LC (HW Rev. 3.01 or newer)
XFP/8G/1310S/SM/LC
1550 nm types XFP/11G/1550L/SM/LC (HW Rev. 2.00 or newer)
CWDM types XFP/11G/CxxxxL/SM/LC (HW Rev. 2.00 or newer)
XFP/11G/CxxxxV/SM/LC (HW Rev. 2.00 or newer)
XFP/8G/CxxxxL/SM/LC
DWDM types XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev. 4.01, 5.01 or
newer)
XFP/11G/#19xxxL50/SM/LC
XFP/11G/DCTV/SM/LC (HW Rev. 1.01 or newer)
XFP/11G/DCTLNR/SM/LC (HW Rev 1.01 or newer)
XFP/11G/DCTLN/SM/LC (HW Rev 1.01 or newer)
XFP/8G/#xxxxxL/SM/LC#Dxx (HW Rev. 2.00 or newer)1
1. The maximum ambient temperature is restricted to 50°C.

Table below provides information about the 2WCC-PCN-10G network ports.

Table 312: Network Port - General Information


Number of network ports 2
Optical connector type LC
Fiber type SM 9 µm
Type of network port XFP Pluggable

210 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 312: Network Port - General Information (Continued)


Data rates 8.5 Gbit/s, 9.9532 Gbit/s, 10.3125
Gbit/s, 10.7092 Gbit/s, 11.0491 Gbit/s,
11.0957 Gbit/s
Protocols 8G FC, STM-64, OC-192, 10 GbE LAN
PHY, 10 GbE WAN PHY1, OTU2,
OTU1e (OTU2LAN without stuffing),
OTU2e (OTU2LAN with stuffing)
1. STM-64 or OC-192 facility type has to be selected on the corresponding port
in the system management.

The following table provides a summary of the supported network port XFPs.

Table 313: Supported Network Port XFPs


850 nm types XFP/10G/850I/MM/LC (HW Rev. 1.01 or newer)
XFP/8G/850I/MM/LC
1310 nm types XFP/11G/1310S/SM/LC (HW Rev. 3.01 or newer)
XFP/8G/1310S/SM/LC
1550 nm types XFP/11G/1550L/SM/LC (HW Rev. 2.00 or newer)
CWDM types XFP/11G/CxxxxL/SM/LC (HW Rev. 2.00 or newer)
XFP/11G/CxxxxV/SM/LC (HW Rev. 2.00 or newer)
XFP/8G/CxxxxL/SM/LC
DWDM types XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev. 4.01, 5.01 or
newer)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

XFP/11G/#19xxxL50/SM/LC
XFP/11G/DCTV/SM/LC (HW Rev. 1.01 or newer)
XFP/11G/DCTLNR/SM/LC (HW Rev 1.01 or newer)
XFP/11G/DCTLN/SM/LC (HW Rev 1.01 or newer)
XFP/8G/#xxxxxL/SM/LC#Dxx (HW Rev. 2.00 or newer)

This table shows the recommended maximum pre-FEC bit error ratio.

Table 314: Recommended Maximum Pre-FEC BER


GFEC 1 x 10-5
EFEC-2 5 x 10-4

Optical performance of the 2WCC-PCN-10G module is


determined by the XFP pluggable interface. Refer to Chapter 6:
PS

Pluggable Transceivers, of the Module and System Specification


Note Manual, for individual optical specifications.

Module and System Specification 211


2WCC-PCN-10G

This table contains information about the module system performance.


Table 315: System Performance
Max. module 2 µs with OC192 at the client ports and network ports.
delay 3 µs with OC192 at the client ports and OTU2 without FEC at
the network ports.
10 µs with OC192 at the client ports and OTU2 with GFEC at
the network ports.
53 µs with OC192 at the client ports and OTU2 with EFEC at
the network ports.
3 µs with OTU2 without FEC at the client ports and network
ports.
17 µs with OTU2 with GFEC at the client ports and network
ports.
53 µs with OTU2 without FEC at the client ports and OTU2
with EFEC at the network ports.
60 µs with OTU2 with GFEC at the client ports and OTU2
with EFEC at the network ports.
2 µs with 10 GbE LAN PHY at the client ports and network
ports.
2 µs with 10 GbE LAN PHY at the client ports and OTU2,
OTU1e, or OTU2e without FEC at the network ports.
8 µs with 10 GbE LAN PHY at the client ports and OTU2,
OTU1e, or OTU2e with GFEC at the network ports.
50 µs with 10 GbE LAN PHY at the client ports and OTU2,
OTU1e, or OTU2e with EFEC at the network ports.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
3 μs with 8G FC at the client ports and network ports
25 μs with 8G FC at the client ports and OTU without FEC at
the network ports.
32 μs with 8G FC at the client ports and OTU2 with GFEC at
the network ports.
75 μs with 8G FC at the client ports and OTU2 with EFEC at
the network ports.
Number of 15 using 2WCC-PCN-10G as bidirectional single module
regenerators N-N regenerator (OTU2, OTU1e and OTU2e only; no FEC,
allowed in GFEC or EFEC)
data path 15 using 2WCC-PCN-10G as dual bidirectional single
module C-N regenerator (no FEC or GFEC on client ports
only)
7 using WCC-PCTN-10G as back-to-back regenerator
(SDH/SONET/OTN only).
3 using 2WCA-PCN-10G (FEC bypass, C band, ALS
disabled) as bidirectional single module C-N regenerator
(SDH/SONET/10 GbE and OTU2 with 10.709 Gbit/s only).
Max. frame no limitation in transmission (for performance monitoring
size limited to 16387 bytes)

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

212 Module and System Specification


Chapter 3 Core Type Channel Modules

This table shows information about fault monitoring of the module in general.

Table 316: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Client port XFP not approved;
Client port XFP missing;
Client port XFP voltage alarm;
Client port XFP temperature;
Network port XFP not approved;
Network port XFP missing;
Network port XFP voltage alarm;
Network port XFP temperature;

This table shows information about fault monitoring of the client ports.

Table 317: Fault Monitoring Client Interface - General


Physical layer Laser failure;
Laser degrade (based on bias
current);
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Receiver clock synch failure;


Loss of signal (LOS)
STM-64 RS/OC-192 section layer LOF; TIM
STM-64 MS/OC-192 line layer AIS; RDI; SD
OCH/OTU2 layer LOF; LOM; AIS
OTU2 layer - SM byte BDI; SD; TIM
ODU2 layer - PM byte AIS; BDI; OCI; LCK; SD; TIM
ODU2 layer - TCMi byte, i = 1...6 AIS; BDI; OCI; LCK; LTC; SD; TIM
Physical coding sublayer (Ethernet Loss of synchronization; Hi_BER;
PCS)1 Local fault
8G FC Physical coding sublayer Loss of synchronization
(PCS)
1. valid for 10 GbE

This table shows information about fault monitoring of the module network ports.

Table 318: Fault Monitoring Network Interface - General


Physical layer Laser failure;
Laser degrade;
Receiver clock synch failure;
Loss of signal (LOS)
STM-64 RS/OC-192 section layer LOF; TIM
STM-64 MS/OC-192 line layer AIS; RDI; SD
OCH/OTU2 layer LOF; LOM; AIS
OTU2 layer - SM byte BDI; SD; TIM

Module and System Specification 213


2WCC-PCN-10G

Table 318: Fault Monitoring Network Interface - General


ODU2 layer - PM byte AIS; BDI; OCI; LCK; SD; TIM
ODU2 layer -TCMi byte, i = 1 ... 6 AIS; BDI; OCI; LCK; LTC; SD; TIM
OPU2 layer AIS; PLM
Physical coding sublayer (Ethernet Loss of synchronization; Hi_BER;
PCS)1 Local fault
8G FC Physical coding sublayer Loss of synchronization
(PCS)
1. valid for 10 GbE

The following table provides information about performance monitoring of the


module in general.

Table 319: Performance Monitoring - General


Equipment Module temperature (current value)
(Fix threshold crossing alert for
module temperature too high
available)
Physical layer Transmitter bias current (current);
(15 min/24 h records available for PM Optical power Rx (current, low,
values except current values; mean, high);
user configurable threshold crossing Optical power Tx (current, low,
alerts for OPR too high/too low mean, high)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
available;
fix threshold crossing alerts for OPT
too high/too low available)

The following table gives information about performance monitoring of the client
ports in the ingress direction.

Table 320: Performance Monitoring Client Interface - Ingress Direction


STM-64 RS/OC-192 section layer ES; SES; OOFS/SEFS;
(15 min/24 h records with user BBE/CV
configurable threshold crossing alerts
available)
STM-64 MS/OC-192 line layer ES; SES; UAS; BBE/CV
(15 min/24 h records with user
configurable threshold crossing alerts
available)
OCH/OTU2 layer ES; SES; UBE; CE;
(15 min/ 24 h records with user BERCE-FEC
configurable threshold crossing alerts
available)
OTU2 layer - SM byte ES; SES; UAS; BBE
(15 min/ 24 h records with user
configurable threshold crossing alerts
available)

214 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 320: Performance Monitoring Client Interface - Ingress Direction


ODU2 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
ODU2 layer - TCMi byte, i = 1 ... 6 ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
Ethernet Physical coding sublayer (PCS)1 ES; CV; SE
Framed 10 GbE services RX Good frames; RX Pause
frames; RX CRC frames;
Received bytes
8G FC Physical coding sublayer (PCS) ES; CV; DE
1. valid for 10 GbE

The following table gives information about performance monitoring of the client
ports in the egress direction.

Table 321: Performance Monitoring Client Interface - Egress Direction


Framed 10 GbE services TX Good frames; TX Pause
frames; TX CRC frames;
Transmitted bytes
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

This table shows information about performance monitoring of the network


ports.

Table 322: Performance Monitoring Network Interface


STM-64 RS/OC-192 section layer ES; SES; SEFS/OOFS;
(15 min/24 h records with user CV/BBE
configurable threshold crossing alerts
available)
STM-64 MS/OC-192 line layer ES; SES; UAS; CV/BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
OCH/OTU2 layer ES; SES; UBE; CE;
(15 min/ 24 h records with user BERCE-FEC
configurable threshold crossing alerts
available)
OTU2 layer - SM byte ES; SES; UAS; BBE
(15 min/ 24 h records with user
configurable threshold crossing alerts
available)
ODU2 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)

Module and System Specification 215


2WCC-PCN-10G

Table 322: Performance Monitoring Network Interface (Continued)


ODU2 layer - TCMi byte, i = 1 ... 6 ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
Physical coding sublayer (PCS)1 ES
Framed 10 GbE services RX Good frames; RX Pause
frames; RX CRC frames;
Received bytes
1. valid for 10 GbE

The following table provides information about the loop functionality.

Table 323: Loop Functionality


Client ports Facility loop, Terminal loop
Network ports Facility loop, Terminal loop

This table provides information about protection switching.


Table 324: Protection Switching
Protection scheme Client channel card protection,
channel protection
Protection switching time < 50 ms

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Client port switching criteria Client XFP removed, (Switching
criteria applies to Client Channel Card
Protection only, but not to Channel
Protection.)
Network signal fail switching LOS, Receiver clock synch failure
criteria physical
Network signal fail switching LOF-S, AIS-L
criteria
STM-64/OC-192
Network signal fail switching OTU-LOF, OTU-AIS, OTU-LOM,
criteria OTN ODU-AIS, ODU-LCK, ODU-OCI
Network signal degrade switching SD-L (MS-DEG/SD based on B2) with
criteria provisionable threshold.
STM-64/OC-192 Support of enabling/disabling SD-L
based on B2 as protection.
Network signal degrade switching SNC/N ODU-SD (based on PM[2])
criteria OTN with provisionable threshold.
Support of enabling/disabling SD
based on PM[2] as protection.
Network physical coding switching Loss of Synch, HI_BER, Local Fault
criteria
Restoration scheme Versatile switched protection,
The module must not be configured to
Client channel card protection.
(RSM-OLM, VSM)
Restoration time <1s

216 Module and System Specification


Chapter 3 Core Type Channel Modules

This table provides information about the ECC.

Table 325: Embedded Control Channel (ECC)


Network ports SDCC (192 kbit/s), GCC0 (1312 kbit/s)
GCC0S (82 kbit/s), GCC1 (1312 kbit/s)
GCC2 (1312 kbit/s)
Client ports SDCC (192 kbit/s), GCC0 (1312 kbit/s)
GCC0S (82 kbit/s), GCC1 (1312 kbit/s)
GCC2 (1312 kbit/s)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 217


2TWCC-PCN-2G7U

2TWCC-PCN-2G7U
The 2TWCC-PCN-2G7U is a 2.7 Gbit/s core type WDM channel module with
two pluggable client and two pluggable network interfaces. The module can
operate as a single or a dual transponder or as a multiplexer. When operating
as a single transponder, it is possible to transport one unprotected or channel
protected OTU1, one STM-16/OC-48/OTU1 or one STM-16/OC-48 wrapped
into an OTU1. When operating as a dual transponder, it is possible to transport
two unprotected STM-16/OC-48/OTU1, or two STM-16/OC-48 wrapped into
OTU1, or two OTU1 services.
The Transponder Modes (both dual transponder and protected transponder)
support the following applications:
• OTU1 to OTU1
• STM-16/OC-48 to STM-16/OC-48
• STM-16/OC-48 to OTU1
When operating as a 2 port Multiplexer, two mapping/multiplexing methods are
available, an SDH/SONET method and an OTN method.
When operating as a SDH/SONET multiplexer, unprotected or channel
protected transport of 2x GbE or 2x G FC or 1GbE and 1G FC or 1x 2G FC
services are possible. The client signals are multiplexed into one
STM-16/OC-48 using GFP-T and continuous concatenation. The STM-16/OC48
signal may be transported in its native form or as an OTU1 (the STM-16/OC48

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
signal is wrapped into the OTU1). The 2G FC service is only allowed to be
applied at client port 1.
The OTN method maps GbE into an ODU0 which are multiplexed into an OTU1.
When rate limiting is not used, GBE is mapped into the ODU0 using TTT/GMP.
When rate limiting is used, GBE is mapped into ODU0 using GFP-F. The
resulting ODU0s are multiplexed into an OPU1/ODU1/OTU1 for transport.
The module supports Channel protection and Client Channel Card protection
(CCCP). CCCP is available for all modes and conditions with the exception of
an OTN Muxponder when rate limiting is used.
Performance monitoring and fault management of physical layer alarms on
client and network ports are also supported.
Table 326 provides general information about the module and its environment.

Table 326: General Information


Equipment type 2TWCC2G7
First release 8.3
Width 4 HP
Height 5 HU
Weight with SFP 620 g (1.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
MTBF at 25°C ambient temperature 394,047 h
Typ. power consumption (incl. SFPs) 25 W
Max. power consumption (incl. SFPs) 30 W

218 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 326: General Information (Continued)


Maximum RAM consumption on NCU 859 Kbytes
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P

Table 327 provides information about the client ports.

Table 327: Client Ports


Number of client ports 2
Data rates multiplexer mode and 1.0625 Gbit/s, 1.250 Gbit/s, 
SDH/SONET mapping/multiplexing 2.125 Gbit/s,
method
Data rates multiplexer mode and 1.250 Gbit/s
OTN mapping/multiplexing method
Data rates transponder mode 2.48832 Gbit/s, 2.666057 Gbit/s
Protocols multiplexer mode and GbE, 1G FC, 2G FC1
SDH/SONET mapping method
Protocols multiplexer mode and GbE
OTN mapping method
Protocols transponder mode STM-16, OC-48, OTU1
Type of client ports SFP
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

1. 2G FC is not supported on client port 2

Table 328 provides a summary of the supported client SFPs. Please refer to the
specifications for the individual SFP type.

Table 328: Supported Client SFPs


850 nm types SFP/2G1/850I/MM/LC
1310 nm types SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
SFP/HS/1310S/SM/LC
SFP/CL/1310I/SM/LC
CWDM types SFP/2G5U/CxxxxL/SM/LC
SFP/2G5U/CxxxxV/SM/LC
DWDM types SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx1
1. supported in pass-through only (OTU1 regenerator)

Table 329 provides information about the network ports.

Table 329: Network Ports


Number of network ports 2
Data rates 2.48832 Gbit/s STM-16/OC-48,
2.666057 Gbit/s OTU1
Protocols OTU1, STM-16, OC-48
Type of network ports SFP

Module and System Specification 219


2TWCC-PCN-2G7U

Table 330 provides a summary of the supported network SFPs. Please refer to
the specifications of the individual SFP type.

Table 330: Supported Network SFPs


1310 nm types SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
CWDM types SFP/2G5U/CxxxxL/SM/LC
SFP/2G5U/CxxxxV/SM/LC
DWDM types SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx

Table 331 provides information about the framing/mapping.

Table 331: Framing/Mapping


Multiplexer mode: SDH multiplexing structure for GbE, FC services:
SDH/SONET VC4 - VC4-8c - STM16
mapping/multiplexing SDH multiplexing structure for 2G FC services: VC4
method - VC4-16c - STM16
SONET multiplexing structure for GbE, FC services:
GFP -> STS-24c -> STS48.
SONET multiplexing structure for 2G FC services:
STS3cSPE - STS48c - STS48
Support of continuous concatenation
Multiplexer mode: Without rate limit:
OTN GBE->TTT/GMP->ODU0->OPU1/ODU1/OTU1.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
mapping/multiplexing With rate limit:
method GBE->GFP-F->ODU0->OPU1/ODU1/OTU1.
Transponder mode Transmission without protocol modification and
change of data rate (OC-48/STM-16/OTU1 only)
Wrapping Synchronous mapping of STM-16/OC48 into ODU1
and transport of OTU1 acc. to ITU-T G.709

220 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 332 provides information about the system performance.

Table 332: System Performance


Max. module delay STM-16/OC-48 to STM-16/OC-48 with G.709
FEC 2µs
STM-16/OC-48 to OTU1 without G.709 FEC 60µs
STM-16/OC-48 to OTU1 with G.709 FEC 100µs
OTU1 to OTU1 without G.709 FEC 60µs
OTU1 to OTU1 with G.709 FEC 110µs
GbE to STM-16/OC-48 with G.709 FEC 10µs
GbE to OTU1 without G.709 FEC 70µs
GbE to OTU1 with G.709 FEC 110µs
GBE to TTT/GMP/ODU0 without G.709 FEC
<TBDµs
GBE to TTT/GMP/ODU0 with G.709 FEC
<TBDµs
Number of regenerators 7 using WCC-PC1N-2G7U as bidirectional single
module N-C regenerator or back-to-back
regenerator (SDH/SONET/OTN only).
7 using any mixture of the above described
regenerator configurations.
2 using WCA-PCN-2G5U as bidirectional single
module N-N regenerator.
7 using 2TWCC-PCN-2G7U as bidirectional
single module N-C regenerator.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Max. frame size for GbE 9612 bytes

The performance monitoring entry has a monitoring function and has


PS

no impact on the transport services.


Note

Whether fault/performance monitoring entries listed in the following


PS

tables are applicable for a specific deployment depends on the


configuration of the respective interface.
Note

Module and System Specification 221


2TWCC-PCN-2G7U

Table 333 provides information about fault monitoring of the module in general.

Table 333: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Client port SFP missing;
Client port SFP mismatch;
Network port SFP missing;
Network port SFP mismatch

Table 334 provides information about fault monitoring of the client ports.

Table 334: Fault Monitoring Client Interface - General


Physical layer Laser failure;
Laser degrade (based on bias
current);
Receiver clock synch failure;
Loss of signal (LOS)

Table 335 provides information about fault monitoring of the client ports in

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ingress direction.

Table 335: Fault Monitoring Client Interface - Ingress Direction


STM-16 RS/OC-48 section layer LOF, TIM
STM-16 MS / OC-48 line layer AIS; RDI; SD
OCH/OTU1 layer LOF; LOM; AIS
OTU1 layer - SM byte BDI; SD, TIM
ODU1 layer - PM byte AIS; BDI; OCI; LCK; SD, TIM
ODU1 layer - TCMi byte i = 1...6 AIS, BDI, OCI, LCK, LTC, SD, TIM
Physical coding sublayer Loss of character synchronization; SD

Table 336 provides information about fault monitoring of the network ports.

Table 336: Fault Monitoring Network Interface - General


Physical layer Laser failure;
Laser degrade (based on bias
current);
Receiver clock synch failure;
Loss of signal (LOS)

222 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 337 provides information about fault monitoring of the network ports in
egress direction.

Table 337: Fault Monitoring Network Interface - Egress Direction


STM-16 RS/OC-48 section layer LOF, TIM
STM-16 MS / OC-48 line layer AIS; RDI; SD (signal degrade)
OCH/OTU1 layer LOF; LOM; AIS
OTU1 layer - SM byte BDI; SD (signal degrade), TIM
ODU1 layer - PM byte AIS; BDI; OCI; LCK; SD (signal
degrade), TIM
OPU1 layer AIS; PLM
ODU1 layer - TCMi byte i = 1...6 AIS, BDI, OCI, LCK, LTC, SD, TIM
VC-4-8C/STS-24c layer AIS; LOP; RDI; PLM; UNEQ
VC-4-16c/STS-48c layer AIS; LOP; RDI; PLM; UNEQ
GFP common LOF; PLM
GFP-T Loss of client signal far end (10B_ERR,
CMF UPI); Loss of character
synchronization far end (CMF UPI)
ODU0 layer: MSIM, LOFLOM, AIS, BDI, OCI, LCK,
SD, TIM
OPU0 layer: CSF, AIS, PLM

Table 338 provides information about performance monitoring of the module in


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

general.

Table 338: Performance Monitoring - General


Equipment Module temperature (current value)
(Fix threshold crossing alert for
module temperature too high
available)

Table 339 provides information about performance monitoring of the client


ports.

Table 339: Performance Monitoring Client Interface - General


Physical layer Transmitter bias current
(15 min/24 h records available for PM (current);
values except current values; Optical power Rx (current, low,
user configurable threshold crossing mean, high);
alerts for OPR too high/too low available; Optical power Tx (current, low,
fix threshold crossing alerts for OPT too mean, high)
high/too low available)

Module and System Specification 223


2TWCC-PCN-2G7U

Table 340 provides information about performance monitoring of the client ports
in ingress direction.

Table 340: Performance Monitoring Client Interface - Ingress Direction


STM-16 RS/OC-48 section layer ES; SES; OOFS/SEFS;
(15 min/24 h records with user BBE/CV
configurable threshold crossing alerts
available)
STM-16 MS/OC-48 line layer ES; SES; UAS; BBE/CV
(15 min/24 h records with user
configurable threshold crossing alerts
available)
OCH/OTU1 layer CE; UBE; ES; SES; BERCE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
OTU1 layer - SM byte ES; SES; UAS; BBE
(15 min/ 24 h records with user
configurable threshold crossing alerts
available)
ODU1 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ODU1 layer - TCMi byte i = 1...6 ES; SES; UAS; BBE
Physical coding sublayer ES; CV; DE
Ethernet layer GbE service Good frames;
Pause frames;
Discarded frames;
Bad frames (CRC);
Received bytes

Table 341 provides information about performance monitoring of the client ports
in egress direction.

Table 341: Performance Monitoring Client Interface - Egress Direction


Ethernet layer GbE service Good frames;
Pause frames;
Discarded frames;
Bad frames (CRC);
Transmit bytes

224 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 342 provides information about performance monitoring of the network


ports.

Table 342: Performance Monitoring Network Interface - General


Physical layer Transmitter bias current
(15 min/24 h records available for PM (current);
values except current values; Optical power Rx (current, low,
user configurable threshold crossing mean, high);
alerts for OPR too high/too low available; Optical power Tx (current, low,
fix threshold crossing alerts for OPT too mean, high)
high/ too low available)

Table 343 provides information about performance monitoring of the network


ports in egress direction.

Table 343: Performance Monitoring Network Interface - Egress Direction


STM-16 RS/OC-48 section layer ES; SES; OOFS;/SEFS
(15 min/24 h records with user configurable BBE/CV
threshold crossing alerts available)
STM-16 MS/OC-48 line layer ES; SES; UAS; BBE/CV
(15 min/24 h records with user configurable
threshold crossing alerts available)
OCH/OTU1 layer CE; UBE; ES; SES; BERCE
(15 min/24 h records with user configurable
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

threshold crossing alerts available)


OTU1 layer - SM byte ES; SES; UAS; BBE
(15 min/ 24 h records with user configurable
threshold crossing alerts available)
ODU1 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user configurable
threshold crossing alerts available)
ODU1 layer - TCMi byte i = 1...6 ES; SES; UAS; BBE
GFP-T (15 min/24 h records available) Discarded superblocks due to
CRC errors
ODU0 layer - PM byte (15min/24 h records ES; SES, UAS, BBE
with user configurable threshold crossing
alerts available)

Table 344 provides information about the loop functionality.

Table 344: Loop Functionality


Client port Facility loop, Terminal loop
Network ports Facility loop, Terminal loop

Module and System Specification 225


2TWCC-PCN-2G7U

Table 345 provides information about protection switching.

Table 345: Protection Switching


Protection scheme Channel protection, Client Channel
Card Protection (CCCP)
Protection switching time < 50 ms
Signal fail switching criteria LOS, LOC, client plug removal (CCCP)
physical
Signal fail switching criteria LOF-S, AIS-L
SDH/SONET
Signal degrade switching criteria SD-L (MS-DEG/SD based on B2) with
SDH/SONET provisionable threshold.
Support of enabling/disabling
protection switching based on SD-L
(B2)
Signal fail switching criteria OTN OTU-LOF, OTU-AIS, OTU-LOM,
ODU-AIS, ODU-LCK, ODU-OCI
Signal degrade switching criteria SNC/N ODU-SD (based on PM[2]) with
OTN provisionable threshold;
Support of enabling / disabling
protection switching based on SD
(PM[2]);
OTU-SD (based on SM[2]) with
provisionable threshold;

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Support of enabling/ disabling SD
based on SM[2] as protection criteria
Signal fail switching criteria AIS-P, LOP-P, UNEQ-P, PLM-P
STM/SONET muxponder path:
Signal Fail switching criteria OTN MSIM, LOFLOM, AIS, LCK, OCI,
muxponder, ODU0 layer:
Signal Fail switching criteria OTN CSF, AIS, PLM
muxponder, OPU0 layer
Signal Fail switching criteria LOF, PLM, client loss of signal, client
loss of character sync.
muxponder, GFP layer:
Restoration scheme Versatile switched protection,
The module must not be configured for
channel protection.
(RSM-SF, RSM-OLM, VSM)
Restoration time <1s

Table 346 provides information about the ECC.

Table 346: Embedded Control Channel (ECC)


Client port GCC0S (82 kbit/s), SDCC (192 kbit/s),
GCC0 (326 kbit/s), GCC1 (326 kbit/s),
GCC2 (326 kbit/s)
Network port GCC0S (82 kbit/s), SDCC (192 kbit/s),
GCC0 (326 kbit/s), GCC1 (326 kbit/s),
GCC2 (326 kbit/s)

226 Module and System Specification


Chapter 3 Core Type Channel Modules

WCC-PC1N-2G7U
The WCC-PC1N-2G7U is a channel module with one SFP type pluggable client
and one SFP type pluggable network interface for data rates up to 2.7 Gbit/s. It
supports STM-1, STM-4, STM-16, OC-3, OC-12, OC-48, OTU1 and GbE
services. STM-16/OC-48 can be mapped according to G.709 resulting in an
OTU1 service. GFEC can be enabled for OTU1 services at both the client port
and the network port.
Table 347 contains general information about the module and its environment.

Table 347: General Information


Equipment type WCC2G7-1N
First release 7.1
Width 4 HP
Height 5 HU
Weight with SFP 520 g (1.1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
MTBF at 25°C ambient temperature 309,477 h
Typ. power consumption (incl. SFPs) 18 W
Max. power consumption (incl. SFPs) 20 W
Maximum RAM consumption on NCU 302 Kbytes
Slot positions SH9HU: 3...18
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

SH7HU, SH7HU-R: 3...18


SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P

The following table provides information about the client port.

Table 348: Client Port


Number of client ports 1
Data rates 155.52 Mbit/s, 622.08 Mbit/s, 1.250 Gbit/s,
2.48832 Gbit/s, 2.666057 Gbit/s
Protocols STM-1, STM-4, STM-16, OC-3, OC-12,
OC-48, OTU1, GbE, ITU-T G.8262 and IEEE
1588v2 compliant transparent Ethernet
transport
Type of client ports SFP

This table provides a summary of the supported client SFPs. Please refer to the
specifications for the individual SFP type.

Table 349: Supported Client SFPs


850 nm types SFP/2G1/850I/MM/LC
1310 nm types SFP/CL/1310I/SM/LC
SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
SFP/HS/1310S/SM/LC

Module and System Specification 227


WCC-PC1N-2G7U

Table 349: Supported Client SFPs (Continued)


CWDM types SFP/2G5U/CxxxxL/SM/LC
SFP/2G5U/CxxxxV/SM/LC
DWDM types SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx

The following table provides information about the network port.

Table 350: Network Port


Number of network ports 1
Data rates 155.52 Mbit/s, 622.08 Mbit/s, 1.250 Gbit/s,
2.48832 Gbit/s, 2.666057 Gbit/s
Protocols STM-1, STM-4, STM-16, OC-3, OC-12,
OC-48, OTU1, GbE
Type of network port SFP

This table provides a summary of the supported network SFPs. Please refer to
the specifications for the individual SFP type.

Table 351: Supported Network SFPs


1310 nm types SFP/CL/1310I/SM/LC
SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
CWDM types SFP/2G5U/CxxxxL/SM/LC

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFP/2G5U/CxxxxV/SM/LC
DWDM types SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx

The following table contains information about framing/mapping.

Table 352: Framing/Mapping


Wrapping mode Wrapping into an OTU1 frame without FEC or with GFEC
on the network interface (only for STM-16 and OC-48)
Transponder Transmission without protocol modification and change
mode of data rate

This table provides information about the system performance.

228 Module and System Specification


Chapter 3 Core Type Channel Modules

Table 353: System Performance


Max. module 20 µs with STM-16, OC-48 and GbE at the client port and
delay with STM-16, OC-48, GbE and OTU1 without FEC at the
network port;
80 µs with STM-16 and OC-48 at the client port and with
OTU1 with GFEC at the network port;
80 µs with OTU1 at the client port and with OTU1 without
FEC at the network port;
120 µs with OTU1 at the client port and with OTU1 with
GFEC at the network port
30 µs with STM-4 and OC-12 at the client and network port
100 µs with STM-1 and OC-3 at both client and network port
Number of 7 using WCC-PC1N-2G7U as bidirectional single module
regenerators N-C regenerator or back-to-back regenerator
(SDH/SONET/OTN only).
7 using any mixture of the above described regenerator
configurations.
2 using WCA-PCN-2G5U as bidirectional single module N-N
regenerator.
Max. frame no limitation
size

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

on the configuration of the respective interface.


Note

This table shows information about fault monitoring of the module in general.

Table 354: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Client port SFP missing;
Client port SFP mismatch;
Network port SFP missing;
Network port SFP mismatch

This table shows information about fault monitoring of the client ports.

Table 355: Fault Monitoring Client Interface


Physical layer Laser failure;
Laser degrade (based on bias
current);
Receiver clock synch failure;
Loss of signal (LOS)

Module and System Specification 229


WCC-PC1N-2G7U

The following table gives information about fault monitoring of the client ports in
ingress direction.

Table 356: Fault Monitoring Client Interface - Ingress Direction


STM-1/4/16 RS/OC-3/12/48 section LOF; TIM
layer
STM-1/4/16 MS/OC-3/12/48 line layer AIS; RDI; SD
OCH/OTU1 layer LOF; LOM; AIS
OTU1 layer - SM byte BDI; SD; TIM
ODU1 layer - PM byte AIS; BDI; OCI; LCK; SD; TIM
ODU1 layer -TCMi byte, i = 1 ... 6 AIS; BDI; OCI; LCK; LTC; SD;
TIM
Physical coding sublayer (PCS) SD; Loss of character
synchronization

This table shows information about fault monitoring of the network ports.

Table 357: Fault Monitoring Network Interface - General


Physical layer Laser failure;
Laser degrade (based on bias current);
Receiver clock synch failure;
Loss of signal (LOS)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table gives information about fault monitoring of the network ports
in egress direction.

Table 358: Fault Monitoring Network Interface - Egress Direction


STM-1/4/16 RS/OC-3/12/48 section LOF; TIM
layer
STM-1/4/16 MS/OC-3/12/48 line layer AIS; RDI; SD
OCH/OTU1 layer LOF; LOM; AIS
OTU1 layer - SM byte BDI; SD; TIM
ODU1 layer - PM byte AIS; BDI; OCI; LCK; SD; TIM
ODU1 layer -TCMi byte, i = 1 ... 6 AIS; BDI; OCI; LCK; LTC; SD; TIM
OPU1 layer PLM
Physical coding sublayer (PCS) SD; Loss of character
synchronization

This table provides information about performance monitoring of the module.

Table 359: Performance Monitoring - General


Equipment Module temperature (current
(Fix threshold crossing alert for module value)
temperature too high available)

230 Module and System Specification


Chapter 3 Core Type Channel Modules

These tables show information about performance monitoring of the client ports.

Table 360: Performance Monitoring Client Interface - General


Physical layer Transmitter bias current
(15 min/24 h records available for PM (current);
values except current values; Optical power Rx (current, low,
user configurable threshold crossing mean, high);
alerts for OPR too high/too low available; Optical power Tx (current, low,
fix threshold crossing alerts for OPT too mean, high)
high/too low available)

Table 361: Performance Monitoring Client Interface - Ingress Direction


STM-1/4/16 RS/OC-3/12/48 section layer ES; SES; OOFS/SEFS;
(15 min/24 h records with user BBE/CV
configurable threshold crossing alerts
available)
STM-1/4/16 MS/OC-3/12/48 line layer ES; SES; UAS; BBE/CV
(15 min/24 h records with user
configurable threshold crossing alerts
available)
OCH/OTU1 layer CE; UBE; ES; SES
(15 min/24 h records with user
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

configurable threshold crossing alerts


available)
OTU1 layer - SM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
ODU1 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
ODU1 layer -TCMi byte, i = 1 ... 6 ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
Physical coding sublayer (PCS) ES; Coding Violation +
Disparity Error (CVDE)

Module and System Specification 231


WCC-PC1N-2G7U

This table shows information about performance monitoring of the network


ports.

Table 362: Performance Monitoring Network Interface - General


Physical layer Transmitter bias current
(15 min/24 h records available for PM (current);
values except current values; Optical power Rx (current, low,
user configurable threshold crossing mean, high);
alerts for OPR too high/too low available; Optical power Tx (current, low,
fix threshold crossing alerts for OPT too mean, high)
high/too low available)

This table shows information about performance monitoring of the network ports
in egress direction.

Table 363: Performance Monitoring Network Interface - Egress Direction


STM-1/4/16 RS/OC-3/12/48 section layer ES; SES; OOFS/SEFS;
(15 min/24 h records with user BBE/CV
configurable threshold crossing alerts
available)
STM-1/4/16 MS/OC-3/12/48 line layer ES; SES; UAS; BBE/CV
(15 min/24 h records with user
configurable threshold crossing alerts
available)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
OCH/OTU1 layer CE; UBE; ES; SES
(15 min/24 h records with user
configurable threshold crossing alerts
available)
OTU1 layer - SM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
ODU1 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
ODU1 layer -TCMi byte, i = 1 ... 6 ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
Physical coding sublayer (PCS) ES; Coding Violation +
Disparity Error (CVDE)

The following table contains information about the loop functionality.

Table 364: Loop Functionality


Client port Facility loop, Terminal loop
Network ports Facility loop, Terminal loop

232 Module and System Specification


Chapter 3 Core Type Channel Modules

This table provides information about protection switching.

Table 365: Protection Switching


Protection scheme Channel card protection
Protection switching time < 50 ms
Signal fail switching criteria physical LOS, Receiver clock synch failure
Signal fail switching criteria LOF-S, AIS-L
SDH/SONET
Signal fail switching criteria OTN OTU-LOF, OTU-AIS, OTU-LOM,
ODU-AIS, ODU-LCK, ODU-OCI
Signal degrade switching criteria SD-L (MS-DEG/SD based on B2) with
SDH/SONET provisionable threshold. Support of
enabling/disabling
SD-L based on B2 as protection.
Signal degrade switching criteria SNC/N ODU-SD (based on PM[2])
OTN with provisionable threshold. Support
of enabling/disabling SD based on
PM[2] as protection.
Signal degrade switching criteria SD-PCS with provisionable threshold.
PCS
Signal fail switching criteria PCS Loss of Synch
Restoration scheme Versatile switched protection,
The module must not be configured to
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

channel card protection.


(RSM-SF, RSM-OLM, VSM)
Restoration time <1s

The following table contains information about the ECC.

Table 366: Embedded Control Channel (ECC)


Client port SDCC (192 kbit/s), GCC0 (326 kbit/s)
GCC0S (82 kbit/s), GCC1 (326 kbit/s)
GCC2 (326 kbit/s)
Network port SDCC (192 kbit/s), GCC0 (326 kbit/s)
GCC0S (82 kbit/s), GCC1 (326 kbit/s)
GCC2 (326 kbit/s)

Module and System Specification 233


234
WCC-PC1N-2G7U

Module and System Specification


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Chapter 4

Access Type Channel Modules


This chapter describes access type channel modules of the FSP 3000R7.
The descriptions of the discontinued access type channel modules can be found
in a former version of the FSP 3000R7 Module and System Specification.
The following sections are provided:
“2PCA-PCN-10G” on p. 236
“10PCA-PCN-1G3+10G” on p. 243
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

“2WCA-PCN-10G” on p. 251
“4TCA-PCN-4GU+4G” on p. 256
“4TCA-PCN-4GUS+4G” on p. 262
“WCA-PCN-2G5U” on p. 268

Module and System Specification 235


2PCA-PCN-10G

2PCA-PCN-10G
The 2PCA-PCN-10G is a 4-port packet channel access module with two 
10 GbE client XFP and two 10 GbE network XFP type pluggable interfaces. It
supports transport, aggregation and cross-connect of up to 400 Ethernet Virtual
Connections (EVCs) in accordance with IEEE 802.1ad Provider Bridges and
MEF10.1 specifications of Ethernet services.
This module is intended to be deployed in an SH9HU, SH7HU, SH1HU-HP/2DC
or SH1HU-R/PF with the following requirements:
• use of the NCU-II or NCU-II-P modules in the network element (NE) of an
SH9HU Shelf
• use of the NCU-II module in the network element (NE) of an SH7HU,
SH1HU-HP/2DC, SH1HU-HP/E-TEMP/2DC or SH1HU-R/PF Shelf
• deployment of a maximum of six Ethernet L2 aggregation modules (six
2PCA-PCN-10G modules or in total a mix of six 2PCA-PCN-10G and
10PCA-PCN-1G3+10G modules) per network element
• support of a maximum of 1600 EVCs per network element
This module can also be deployed in an SH7HU, with the following
requirements and resulting condition:
• deployment of a maximum of three 2PCA-PCN-10G modules in specific slot
positions in the shelf (due to heat dissipation)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• adjacent slots may be equipped with modules with a maximum power
requirement of 10 W
• the network element uses the NCU-II controller
• the network element will be ETSI compliant (maximum ambient temperature
of +45°C or +113°F)
Table 367 contains general information about the module and its environment.

Table 367: General Information


Equipment type 2PCA10G
First release 10.1
Width 8 HP
Height 5 HU
Weight (incl. SFPs and 1.4 kg (3 lbs)
XFPs)
Environmental conditions NEBS Level 3 (not in combination with SH7HU)
ETSI EN 300 019-1-3 Class 3.1
Degree of protection IP20. Use in a pollution degree 2 environment
according to IEC 60529 and indoor controlled office environments only.
MTBF at 25°C ambient 157,634 h
temperature
Typ. power consumption 120 W
(incl. XFPs)
Max. power consumption 135 W
(incl. XFPs)

236 Module and System Specification


Chapter 4 Access Type Channel Modules

Table 367: General Information (Continued)


Slot positions SH9HU: 3...17
SH7HU, SH7HU-R: 3+4, 11+12 and 17+18 only
SH1HU-HP/2DC, SH1HU-R/PF and
SH1HU-HP/E-TEMP/2DC: 1
NCU type1 NCU-II, NCU-II-P (only in SH9HU)
1. NCU-II supports a maximum of six 2PCA-10G modules and 1600 EVCs.

This table provides information about the client port.

Table 368: Client Port


Number of client ports 2
Data rates 10.3125 Gbit/s
Protocols 10 GbE LAN PHY
Type of client ports XFP

The following table provides a summary of the supported client XFPs.

Table 369: Supported Client XFPs


850 nm types XFP/10G/850I/MM/LC
1310 nm types XFP/11G/1310S/SM/LC
1550 nm types XFP/11G/1550L/SM/LC
CWDM types XFP/11G/CxxxxL/SM/LC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

XFP/11G/CxxxxV/SM/LC
DWDM types XFP/11G/Dxxxx.xxV/SM/LC#Dxx
XFP/OTN11G/#19xxxV/SM/LC
XFP/11G/DCTV/SM/LC

This table contains information about the network ports.

Table 370: Network Ports


Number of network ports 2
Data rates 10.3125 Gbit/s
Protocols 10 GbE LAN PHY
Type of network port XFP

The following table provides a summary of the supported network XFPs. Please
refer to the specifications for the individual XFP type.

Table 371: Supported Network XFPs


850 nm types XFP/10G/850I/MM/LC
1310 nm types XFP/11G/1310S/SM/LC
1550 nm types XFP/11G/1550L/SM/LC
CWDM types XFP/11G/CxxxxL/SM/LC
XFP/11G/CxxxxV/SM/LC
DWDM types XFP/11G/Dxxxx.xxV/SM/LC#Dxx
XFP/OTN11G/#19xxxV/SM/LC
XFP/11G/DCTV/SM/LC

Module and System Specification 237


2PCA-PCN-10G

This table provides information about the operation modes.

Table 372: Operation Modes


Port modes Port-based, C-tagged or S-tagged
(IEEE802.1ad)
Port roles of client and network ports UNI, I-NNI, NNI (MEF4)
Ethernet services E-Line: EPL and EVPL (MEF10.1)
E-LAN: EPLAN, EVPLAN (MEF10.1)
Number of Ethernet services (EVCs) 400
Class of service support 1
Routing Add-drop (UNI to NNI, UNI to I-NNI)
Pass-through (NNI to I-NNI, I-NNI to
I-NNI)
Hairpin (UNI to UNI)
Link aggregation Max 2 LAGs per module,
Max 2 ports per LAG (for “1:1”-like
protection switching only)
Max. frame size User configurable in the range 1518 to
9600 bytes (inclusive tags)
Tag handling SVID translation, CVID translation,
Ethertype configurable
S-tag add/drop in S-tagged and port
based modes, C-tag add/drop in
C-tagged mode

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
L2CP (layer 2 control protocol) filter Fixed filters in acc. with MEF6.1
(peer/tunnel/discard)
Policing properties CIR, CBS. User-configurable, individual
per EVC
Shaping properties CIR, CBS. User-configurable, individual
per EVC
MAC learning No
Buffer size 1 Mbit per EVC

This table contains information about the system performance.

Table 373: System Performance


Average module delay between 60 µs
10 GbE LAN PHY ports for 64
byte frames1
Average module delay between 29 µs
10 GbE LAN PHY ports for 1518
byte frames1

238 Module and System Specification


Chapter 4 Access Type Channel Modules

Table 373: System Performance (Continued)


Average module delay between 55 µs
10 GbE LAN PHY ports for 9600
byte frames1
Number of regenerators 3 using WCC-PCTN-10G as back-to-back
regenerator (C band only, ALS disabled).
3 using 2WCC-PCN-10G as bidirectional
single module C-N regenerator
3 using 2WCA-PCN-10G as bidirectional
single module C-N regenerator.
1. Typical module delay measured from Rx on one port to Tx on another port
(uni-directional) on the same module. No congestion. Measuring method:
store and forward according to RFC 1242.

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

This table shows information about fault monitoring of the module in general.

Table 374: Fault Monitoring - General


Equipment Module removed; Module mismatch;
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module voltage abnormal; General hardware


fault; Firmware package mismatch NSA;
Firmware package mismatch SA; Capability
Level mismatch; XFP missing; XFP mismatch
Physical layer Laser failure; Loss of signal (LOS)
Physical coding sublayer Loss of Char Sync (CHARSYNC, IEEE: Block
(PCS) Lock), High BER (HIBER)

The following tables provide information about performance monitoring.

Table 375: Performance Monitoring - General


Equipment (Fix threshold crossing alert for Module temperature
module temperature too high available) (current value)

This table shows information about performance monitoring of the client ports.

Table 376: Performance Monitoring Client Interface - General


Physical layer Transmitter bias current
(15 min/24 h records available for PM values (current);
except current values; user configurable Optical power Rx
threshold crossing alerts for OPR too high/too (current, low, mean, high);
low available; fix threshold crossing alerts for Optical power Tx
OPT too high/too low available) (current, low, mean, high)

Module and System Specification 239


2PCA-PCN-10G

This table shows details about performance monitoring of the network ports.

Table 377: Performance Monitoring Network Interface - General


Physical layer Transmitter bias current (current);
(15 min/24 h records available for PM Optical power Rx
values except current values; user (current, low, mean, high);
configurable threshold crossing alerts Optical power Tx
for OPR too high/too low available) (current, low, mean, high)

This table shows information about performance monitoring of the network ports
and client ports on Rx.

Table 378: Performance Monitoring Client and Network Interface - Rx


Physical coding sublayer (PCS) None
Ethernet MAC layer Rx Bytes1 (excl. pause frames)
Frames1 (excl. pause frames)
Broadcast frames
Multicast frames
Pause frames
64 bytes frames
65 - 127 bytes frames
128 - 255 bytes frames
256 - 511 bytes frames
512 - 1023 bytes frames

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
1024 - 1518 bytes frames
1519 - max frame size frames
Undersized frames (<64 bytes)
Oversized frames (> max frame size)
FCS error frames
Inter-packet junk
Per EVC Rx Unicast frames (prior to policing)
Multicast frames (prior to policing)
Frames marked green (by policer)
Bytes marked green (by policer)
Frames marked red and dropped (by policer)
Bytes marked red and dropped (by policer)
Frames dropped due to buffer overflow
Bytes dropped due to buffer overflow
1. There is a small time difference between the capture of the Bytes and
Frames counters. This is observable when testing with fixed length frames.
The Bytes counter will then not be equal to the Frames counter “frame
length”. The size of the deviation is only linked to the packet rate at the time
the counters are captured.

240 Module and System Specification


Chapter 4 Access Type Channel Modules

The following table shows information about performance monitoring of the


network ports and client ports on Tx.

Table 379: Performance Monitoring Client and Network Interface - Tx


Ethernet MAC layer Tx Bytes (excl. pause frames)
Frames (excl. pause frames)
Broadcast frames
Multicast frames
Pause frames
64 bytes frames
65 - 127 bytes frames
128 - 255 bytes frames
256 - 511 bytes frames
512 - 1023 bytes frames
1024 - 1518 bytes frames
1519 - max frame size frames
Per EVC Tx Unicast frames
Multicast frames

The following table provides information about the loop functionality.

Table 380: Loop Functionality


Client port Facility loop on individual port1
Terminal loop on individual port1
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Network ports Facility loop on individual port1


Terminal loop on individual port1
1. These are not fully transparent, IPG adjustment may occur.

This table provides information about EOC.

Table 381: Embedded Operations Channel (EOC)


Max. number of EOC per module 4
Capacity 1 Mbit/s per EOC
Protocol Ethernet ELine-PPP (IP over PPP
over VLAN EVC) - for interconnect
between 10PCA and 2PCA modules
Ethernet E-TREE (PtMP VLAN EVC) -
for tunneling of FSP150 DCN or an
unit supporting standardized IP over
VLAN management channel
Max. frame size 1500 bytes

This table provides information about connectivity fault management and


ethernet OAM.

Table 382: Connectivity Fault Management / Ethernet OAM


Standard references MEF 17, ITU-T Y.1731, IEEE 802.1ag
Number of MEPs per module 400

Module and System Specification 241


2PCA-PCN-10G

Table 382: Connectivity Fault Management / Ethernet OAM (Continued)


Supported on interfaces UNI, NNI, I-NNI
Supported on port modes S-tagged
Type of MEPs supported Down-MEP
Protocols supported CCM / ETH-CC, RDI
CCM rates 3.3 ms, 10 ms, 100 ms, 1 sec, 10 sec,
1 min, 10 min

This table provides information about ethernet linear protection.

Table 383: Protection Switching - Ethernet Linear Protection


Protection scheme Ethernet Linear Protection (ITU-T G.8031)
Protection characteristics 1+1 uni-directional switching, non-revertive
Protection switching time < 50 ms
Number of protected EVCs 200
Protection group supported on I-NNI (S-tagged always)
Protected services E-Line (EVP, EVPL)
Operations Manual switch, Freeze, Clear
Switching criteria Loss of CCM / ETH-CC

This table provides information about Link Aggregation protection.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 384: Protection Switching - Link Aggregation Protection
Protection scheme Link Aggregation, active-standby 
(IEEE 802.1ax)
Protection characteristics • "1:1"-like protection, bi-directional
switching
• revertive and non-revertive
Protection switching time < 6 sec
Protection group supported on all ports, all port modes, all port roles
Operations Switching possible by manipulating port
priority
Switching criteria LOS, LACP timeout

242 Module and System Specification


Chapter 4 Access Type Channel Modules

10PCA-PCN-1G3+10G
The 10PCA-PCN-1G3+10G is a 12-port packet channel access module with ten
1 GbE client SFP and two 10 GbE network XFP type pluggable interfaces. It
supports transport, aggregation and cross-connect of up to 400 Ethernet Virtual
Connections (EVCs) in accordance with IEEE 802.1ad Provider Bridges and
MEF10.1 specifications of Ethernet services.
This module is intended to be deployed in an SH9HU, SH7HU, SH1HU-HP/2DC
or SH1HU-R/PF with the following requirements:
• use of the NCU-II or NCU-II-P modules in the network element (NE) of an
SH9HU Shelf
• use of the NCU-II module in the network element (NE) of an SH7HU,
SH1HU-HP/2DC, SH1HU-HP/E-TEMP/2DC or SH1HU-R/PF Shelf
• deployment of a maximum of six Ethernet L2 aggregation modules (six
10PCA-PCN-1G3+10G modules or in total a mix of six 2PCA-PCN-10G and
10PCA-PCN-1G3+10G modules) per network element
• support of a maximum of 1600 EVCs per network element
This module can also be deployed in an SH7HU, with the following
requirements and resulting condition:
• deployment of a maximum of three 10PCA-PCN-1G3+10G modules in
specific slot positions in the shelf (due to heat dissipation)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

• adjacent slots may be equipped with modules with a maximum power


requirement of 10 W
• the network element uses the NCU-II controller
• the network element will be ETSI compliant (maximum ambient temperature
of +45°C or +113°F)
Table 385 contains general information about the module and its environment.

Table 385: General Information


Equipment type 10PCA10G
First release 9.1
Width 8 HP
Height 5 HU
Weight (incl. SFPs and 1.4 kg (3 lbs)
XFPs)
Environmental conditions NEBS Level 3 (not in combination with SH7HU)
ETSI EN 300 019-1-3 Class 3.1
Degree of protection IP20. Use in a pollution degree 2 environment
according to and indoor controlled office environments only.
IEC 60529
MTBF at 25°C ambient 156,666 h
temperature
Typ. power consumption 120 W
(incl. SFPs and XFPs)
Max. power consumption 135 W
(incl. SFPs and XFPs)

Module and System Specification 243


10PCA-PCN-1G3+10G

Table 385: General Information (Continued)


Slot positions SH9HU: 3...17
SH7HU/SH7HU-R: 3+4, 11+12 and 17+18 only
SH1HU-HP/2DC, SH1HU-HP/E-TEMP/2DC,
SH1HU-R/PF: 1
NCU type1 NCU-II, NCU-II-P (only in SH9HU)
1. NCU-II supports a maximum of six 10PCA modules and 1600 EVCs.

This table provides information about the client port.

Table 386: Client Port


Number of client ports 10
Data rates 1.250 Gbit/s
Protocols GbE
Type of client ports SFP

The following table provides a summary of the supported client SFPs. Please
refer to the specifications for the individual SFP type.

Table 387: Supported Client SFPs


850 nm types SFP/2G1/850I/MM/LC
1310 nm types SFP/HS/1310S/SM/LC
SFP/2G5U/1310S/SM/LC

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFP/2G5U/1310L/SM/LC
CWDM SFP/2G5U/CxxxxL/SM/LC
SFP/2G5U/CxxxxV/SM/LC
DWDM types SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx

This table contains information about the network ports.

Table 388: Network Ports


Number of network ports 2
Data rates 10.3125 Gbit/s
Protocols 10 GbE LAN PHY
Type of network port XFP

The following table provides a summary of the supported network XFPs. Please
refer to the specifications for the individual XFP type.

Table 389: Supported Network XFPs


850 nm types XFP/10G/850I/MM/LC
1310 nm types XFP/11G/1310S/SM/LC
1550 nm types XFP/11G/1550L/SM/LC
CWDM types XFP/11G/CxxxxL/SM/LC
XFP/11G/CxxxxV/SM/LC
DWDM types XFP/11G/Dxxxx.xxV/SM/LC#Dxx
XFP/OTN11G/#19xxxV/SM/LC
XFP/11G/DCTV/SM/LC

244 Module and System Specification


Chapter 4 Access Type Channel Modules

This table provides information about the operation modes.

Table 390: Operation Modes


Port modes Port-based, C-tagged or S-tagged
(IEEE802.1ad)
Port roles of client and network ports UNI, I-NNI, NNI (MEF4)
Ethernet services E-Line: EPL and EVPL (MEF10.1)
E-LAN: EPLAN, EVPLAN (MEF10.1)
Number of Ethernet services (EVCs) 400
Class of service support 1
Routing Add-drop (UNI to NNI, UNI to I-NNI)
Pass-through (NNI to I-NNI, I-NNI to
I-NNI)
Hairpin (UNI to UNI)
Link aggregation Max 6 LAGs per card,
Max 2 ports per LAG (for “1:1”-like
protection switching only)
Max. frame size User configurable in the range 1518 to
9600 bytes (inclusive tags)
Tag handling SVID translation, CVID translation,
Ethertype configurable
S-tag add/drop in S-tagged and port
based modes, C-tag add/drop in
C-tagged mode
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

L2CP (layer 2 control protocol) filter Fixed filters in acc. with MEF6.1
(peer/tunnel/discard)
Policing properties CIR, CBS. User-configurable, individual
per EVC
Shaping properties CIR, CBS. User-configurable, individual
per EVC
MAC learning No
Buffer size 1 Mbit per EVC

This table contains information about the system performance.


Table 391: System Performance
40 flows1 400 flows1
(4 per client port) (40 per client port)
Average module delay for 64 153 µs (50% load) 284 µs (50% load)
byte frames2 178 µs (80% load) 239 µs (80% load)
200 µs (90% load) 234 µs (90% load)
202 µs (95% load) 240 µs (95% load)
Average module delay for 162 µs (50% load) 188 µs (50% load)
128 byte frames2 171 µs (80% load) 247 µs (80% load)
190 µs (90% load) 236 µs (90% load)
201 µs (95% load) 235 µs (95% load)

Module and System Specification 245


10PCA-PCN-1G3+10G

Table 391: System Performance (Continued)


Average module delay for 143 µs (50% load) 86 µs (50% load)
256 byte frames2 174 µs (80% load) 158 µs (80% load)
182 µs (90% load) 166 µs (90% load)
205 µs (95% load) 176 µs (95% load)
Average module delay 81 µs (50% load) 54 µs (50% load)
between for 512 byte 98 µs (80% load) 115 µs (80% load)
frames2 123 µs (90% load) 134 µs (90% load)
135 µs (95% load) 163 µs (95% load)
Average module delay 60 µs (50% load) 60 µs (50% load)
between for 1024 byte 61 µs (80% load) 61 µs (80% load)
frames2 62 µs (90% load) 62 µs (90% load)
62 µs (95% load) 62 µs (95% load)
Average module delay 65 µs (50% load) 65 µs (50% load)
between for 1280 byte 66 µs (80% load) 65 µs (80% load)
frames2 66 µs (90% load) 66 µs (90% load)
67 µs (95% load) 67 µs (95% load)
Average module delay 62 µs (50% load) 69 µs (50% load)
between for 1518 byte 70 µs (80% load) 69 µs (80% load)
frames2 71 µs (90% load) 71 µs (90% load)
70 µs (95% load) 70 µs (95% load)
Average module delay 184 µs (50% load) 221 µs (50% load)
between for 9600 byte 235 µs (80% load) 233 µs (80% load)
frames2 235 µs (90% load) 233 µs (90% load)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
231 µs (95% load) 231 µs (95% load)
Number of regenerators 3 using WCC-PCTN-10G as back-to-back
regenerator (C band only, ALS disabled)
3 using 2WCC-PCN-10G as bidirectional
single module C-N regenerator
3 using 2WCA-PCN-10G as bidirectional
single module C-N regenerator
1. The 40 and 400 flows columns are the number of flows scheduled on the
network port in each case. The load numbers are the traffic load on the
network port.
2. The module delay numbers are the sum of module delay from client port to
network port and from network port back to client port.

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

246 Module and System Specification


Chapter 4 Access Type Channel Modules

This table shows information about fault monitoring of the module in general.

Table 392: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Capability Level mismatch;
Client port SFP missing;
Client port SFP mismatch;
Network port XFP missing;
Network port XFP mismatch

The following tables show information about fault monitoring.

Table 393: Fault Monitoring Client Interface - General


Physical layer Laser failure; Loss of signal (LOS)
Physical coding sublayer (PCS) Link down (based on Autoneg)

This table shows information about fault monitoring of the network ports.

Table 394: Fault Monitoring Network Interface - General


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Physical layer Laser failure; Loss of signal (LOS)


Physical coding Loss of Char Sync (CHARSYNC, IEEE: Block Lock)
sublayer (PCS) High BER (HIBER)

The following tables provide information about performance monitoring.

Table 395: Performance Monitoring - General


Equipment Module temperature (current value)
(Fix threshold crossing alert for module
temperature too high available)

This table shows information about performance monitoring of the client ports in
general.

Table 396: Performance Monitoring Client Interface - General


Physical layer Transmitter bias current
(15 min/24 h records available for PM values (current);
except current values; user configurable Optical power Rx
threshold crossing alerts for OPR too high/too low (current, low, mean, high);
available; fix threshold crossing alerts for OPT too Optical power Tx
high/too low available) (current, low, mean, high)

Module and System Specification 247


10PCA-PCN-1G3+10G

The following table shows information about performance monitoring of the


network ports in general.

Table 397: Performance Monitoring Network Interface - General


Physical layer Transmitter bias current (current);
(15 min/24 h records available for PM Optical power Rx
values except current values; user (current, low, mean, high);
configurable threshold crossing alerts for Optical power Tx
OPR too high/too low available) (current, low, mean, high)

This table shows information about performance monitoring of the network and
client ports on Rx.

Table 398: Performance Monitoring Client and Network Interface - Rx


Physical coding sublayer (PCS) None
Ethernet MAC layer Rx Bytes1 (excl. pause frames)
Frames1 (excl. pause frames)
Broadcast frames
Multicast frames
Pause frames
64 bytes frames
65 - 127 bytes frames
128 - 255 bytes frames
256 - 511 bytes frames

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
512 - 1023 bytes frames
1024 - 1518 bytes frames
1519 - max frame size frames
Undersized frames (<64 bytes)
Oversized frames (> max frame size)
FCS error frames
Inter-packet junk (Network Interface only)
Per EVC Rx Unicast frames (prior to policing)
Multicast frames (prior to policing)
Frames marked green (by policer)
Bytes marked green (by policer)
Frames marked red and dropped (by policer)
Bytes marked red and dropped (by policer)
Frames dropped due to buffer overflow
Bytes dropped due to buffer overflow
1. There is a small time difference between the capture of the Bytes and
Frames counters. This is observable when testing with fixed length frames.
The Bytes counter will then not be equal to the Frames counter “frame
length”. The size of the deviation is only linked to the packet rate at the time
the counters are captured.

248 Module and System Specification


Chapter 4 Access Type Channel Modules

The following table shows information about performance monitoring of the


network ports and client ports on Tx.

Table 399: Performance Monitoring Client and Network Interface - Tx


Ethernet MAC layer Tx Bytes (excl. pause frames)
Frames (excl. pause frames)
Broadcast frames
Multicast frames
Pause frames
64 bytes frames
65 - 127 bytes frames
128 - 255 bytes frames
256 - 511 bytes frames
512 - 1023 bytes frames
1024 - 1518 bytes frames
1519 - max frame size frames
Per EVC Tx Unicast frames
Multicast frames

The following table provides information about the loop functionality.

Table 400: Loop Functionality


Client port Facility loop on individual port1
Terminal loop on individual port1
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Network ports Facility loop on individual port1


Terminal loop on individual port1
1. These are not fully transparent, IPG adjustment may occur.

This table provides information about EOC.

Table 401: Embedded Operations Channel (EOC)


Max. number of EOC per module 12
Capacity 1 Mbit/s per EOC
Protocol Ethernet ELine-PPP (IP over PPP
over VLAN EVC) - for interconnect
between 2PCA and 10PCA modules
Ethernet E-TREE (PtP VLAN EVC) -
for tunneling of FSP150 DCN or a unit
supporting standardized IP over VLAN
management channel
Max. frame size 1500 bytes

This table provides information about connectivity fault management and


ethernet OAM.

Table 402: Connectivity Fault Management / Ethernet OAM


Standard references MEF 17, ITU-T Y.1731, IEEE 802.1ag
Number of MEPs per module 400

Module and System Specification 249


10PCA-PCN-1G3+10G

Table 402: Connectivity Fault Management / Ethernet OAM (Continued)


Supported on interfaces UNI, NNI, I-NNI
Supported on port modes S-tagged
Type of MEPs supported Down-MEP
Protocols supported CCM / ETH-CC, RDI
CCM rates 3.3 ms, 10 ms, 100 ms, 1 sec, 10 sec,
1 min, 10 min

This table provides information about ethernet linear protection.

Table 403: Protection Switching - Ethernet Linear Protection


Protection scheme Ethernet Linear Protection (ITU-T G.8031)
Protection characteristics 1+1 uni-directional switching, non-revertive
Protection switching time < 50 ms
Number of protected EVCs 200
Protection group supported on I-NNI (S-tagged always)
Protected services E-Line (EVP, EVPL)
Operations Manual switch, Freeze, Clear
Switching criteria Loss of CCM / ETH-CC

This table provides information about Link Aggregation protection.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 404: Protection Switching - Link Aggregation Protection
Protection scheme Link Aggregation, active-standby 
(IEEE 802.1ax)
Protection characteristics • "1:1"-like protection, bi-directional
switching
• revertive and non-revertive
Protection switching time < 6 sec
Protection group supported on all ports, all port modes, all port roles
Operations Switching possible by manipulating port
priority
Switching criteria LOS, LACP timeout

250 Module and System Specification


Chapter 4 Access Type Channel Modules

2WCA-PCN-10G
The 2WCA-PCN-10G is a 10G channel module with two XFP type pluggable 
client and two XFP type pluggable network interfaces. The module supports 4G
FC, 8G FC, STM-64/OC-192, 10G FC, 10 GbE WAN PHY, 10 GbE LAN PHY
and OTU2.
The 2WCA-PCN-10G is intended to be used as:
• Unprotected single transponder or regenerator (C1 to NE or C2 to NW)
• Unprotected dual transponder or regenerator (C1 to NE and C2 to NW)
• Channel protected single transponder (C1 to NW/NE)
It provides performance monitoring at the client as well as at the network ports
for the physical layer.
Table 405 contains general information about the module and its environment.

Table 405: General Information


Equipment type 2WCA10G
First release 9.1
Width 4 HP
Height 5 HU
Weight (incl. XFP) 650 g (1.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

ETSI EN 300 019-1-3 Class 3.1


Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 489,200 h
Typ. power consumption (incl. XFPs) 14 W
Max. power consumption (incl. XFP) 20 W
Maximum RAM consumption on 440 Kbytes
NCU
Slot positions SH9HU: 3...18,
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P

The following table provides information about the client port.

Table 406: Client Port


Number of client ports 2
Data rates 4.25 Gbit/s, 8.5 Gbit/s, 9.9532 Gbit/s, 
10.3125 Gbit/s, 10.51875 Gbit/s, 10.709 Gbit/s
Protocols 4G FC, 8G FC, 10 GbE WAN PHY, 10 GbE LAN
PHY, STM-64/OC-192, 10G FC, OTU2
Type of client port XFP

Module and System Specification 251


2WCA-PCN-10G

The following table provides a summary of the supported client XFPs. Please
refer to the specifications of the individual XFP type.

Table 407: Supported Client XFPs


850 nm types XFP/10G/850I/MM/LC
XFP/8G/850I/MM/LC
1310 nm types XFP/11G/1310S/SM/LC
(HW Rev. 2.03 or newer)
XFP/8G/1310S/SM/LC
1550 nm types XFP/11G/1550L/SM/LC
CWDM types XFP/8G/CxxxxL/SM/LC
XFP/11G/CxxxxL/SM/LC
XFP/11G/CxxxxV/SM/LC
DWDM types XFP/8G/#xxxxxL/SM/LC#Dxx1
XFP/11G/Dxxxx.xxV/SM/LC#Dxx1
XFP/11G/DCTV/SM/LC1
XFP/11G/#19xxxL50/SM/LC 1
XFP/16GFC/#19xxxL50/SM/LC1
1. In regenerator mode only.

The following table provides information about the network port.

Table 408: Network Port

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Number of network ports 2
Type of network ports XFP
Data rates 4.25 Gbit/s, 8.5 Gbit/s, 9.9532 Gbit/s, 
10.3125 Gbit/s, 10.51875 Gbit/s, 10.709 Gbit/s

The following table provides a summary of the supported network XFPs. Please
refer to the specifications of the individual XFP type.
Table 409: Supported Network XFPs
850 nm types XFP/10G/850I/MM/LC
1310 nm types XFP/11G/1310S/SM/LC
(HW Rev. 2.03 or newer)
1550 nm types XFP/11G/1550L/SM/LC
CWDM types XFP/8G/CxxxxL/SM/LC
XFP/11G/CxxxxL/SM/LC
XFP/11G/CxxxxV/SM/LC
DWDM types XFP/8G/#xxxxxL/SM/LC#Dxx
XFP/11G/Dxxxx.xxV/SM/LC#Dxx1
XFP/11G/DCTV/SM/LC
XFP/11G/#19xxxL50/SM/LC
XFP/16GFC/#19xxxL50/SM/LC

252 Module and System Specification


Chapter 4 Access Type Channel Modules

1. When the XFP/11G/Dxxxx.xxV/SM/LC#Dxx with HW revisions 2.xx or 4.xx


are being used in a network containing 2RAMAN-C15-LL optical amplifiers
and TWRS fiber, the user must select "FWD RAMAN" for the Decision
Threshold setting to ensure proper operation. Using an
XFP/11G/Dxxxx.xxV/SM/LC#Dxx with HW revisions 5.xx in such a network a
“Threshold setting fail” alarm will be raised.

This table contains information about the system performance.

Table 410: System Performance


Max. module delay (without < 4 ns
XFPs)
Number of regenerators 15 using 2WCA-PCN-10G as bidirectional
single module C-N regenerator.
Max. frame size no limitation

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

This table shows information about fault monitoring of the module in general.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 411: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Client port XFP missing;
Client port XFP mismatch;
Capability mismatch

This table shows information about fault monitoring of the client ports in general.

Table 412: Fault Monitoring Client Interface - General


Physical layer Laser failure;
Laser degrade (based on bias current);
Loss of signal (LOS)

This table shows information about fault monitoring of the network ports in
general.

Table 413: Fault Monitoring Network Interface - General


Physical layer Laser failure;
Receiver clock synch failure;
Loss of signal (LOS)

Module and System Specification 253


2WCA-PCN-10G

The following table provides information about performance monitoring of the


module in general.

Table 414: Performance Monitoring - General


Equipment Module temperature (current value)
(Fix threshold crossing alert for module
temperature too high available)

This table shows information about performance monitoring of the client ports in
general.

Table 415: Performance Monitoring Client Interface - General


Physical layer Transmitter bias current (current);
(15 min/24 h records available for PM Optical power Rx (current, low,
values except current values; mean, high);
user configurable threshold crossing alerts Optical power Tx (current, low,
for OPR too high/too low available; mean, high)
fix threshold crossing alerts for OPT too
high/too low available)

This table gives information about performance monitoring of the client ports.

Table 416: Performance Monitoring Client Interface


Data layer (15 min/24 h records available) Defect seconds (DS)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table shows information about performance monitoring of the network ports
in general.

Table 417: Performance Monitoring Network Interface - General


Physical layer Transmitter bias current (current);
(15 min/24 h records available for PM Laser temperature (current);
values except current values; Optical power Rx (current, low,
user configurable threshold crossing alerts mean, high)
for OPR too high/too low available)

The following table gives information about performance monitoring of the


network ports.

Table 418: Performance Monitoring Network Interface


Data layer (15 min/24 h records available) Defect seconds (DS)

The following table provides information about the loop functionality.

Table 419: Loop Functionality


Client port Facility loop
Network port Facility loop

254 Module and System Specification


Chapter 4 Access Type Channel Modules

This table provides information about protection switching.

Table 420: Protection Switching


Protection scheme Versatile switched protection
(RSM-SF, RSM-OLM, VSM), if the
module is not configured to channel
protection;
Channel protection
Protection switching time < 50 ms
Protection switching criteria for LOS, Receiver clock sync failure
channel protection
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 255


4TCA-PCN-4GU+4G

4TCA-PCN-4GU+4G
The 4TCA-PCN-4GU+4G is an access type 4-port time division multiplexing
channel module with four client and two network SFP type pluggable interfaces.
All client and network interfaces are SFP types. It supports the transport of GbE,
1G, 2G or 4G FC signals. These applications are multiplexed to a data rate of
4.25 Gbit/s with a proprietary protocol for transmission at the network interfaces.
The network interfaces provide channel protection as well. 
The 4TCA-PCN-4GU+4G features dynamic add/drop traffic per client interface
to multiplex and demultiplex the transmitted signal.
Table 421 contains general information about the module and its environment.

Table 421: General Information


Equipment type 4TCA4G
First release 8.1
Width 4 HP
Height 5 HU
Weight (incl. SFPs) 640 g (1.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 355,216 h
Typ. power consumption (incl. SFPs) 16 W in converter mode (TRANSW)
22 W in all other modes
Max. power consumption (incl. SFPs) 18 W in converter mode (TRANSW)
25.0 W in all other modes
Maximum RAM consumption on NCU 1,376 Kbytes
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P

The following table provides information about the client ports.

Table 422: Client Ports


Number of client ports 4
Data rates 1.0625 Gbit/s, 1.25 Gbit/s, 2.125 Gbit/s, 4.25 Gbit/s
Protocols GbE, 1G FC, 2G FC, 4G FC, 2G Coupling Link with
disabled disparity control, ITU-T G.8262 and IEEE
1588v2 compliant transparent Ethernet transport 1
Type of client ports SFP

1. Not for pass-through network-to-network

256 Module and System Specification


Chapter 4 Access Type Channel Modules

The following table provides a summary of the supported client SFPs. Please
refer to the specifications of the individual SFP type.

Table 423: Supported Client SFPs


850 nm types SFP/2G1/850I/MM/LC
SFP/4GU/850I/MM/LC
SFP/GBE/850I/MM/LC/TIN
1310 nm types SFP/HS/1310S/SM/LC
SFP/CL/1310I/SM/LC
SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
SFP/4GU/1310S/SM/LC
SFP/GBE/1310S/SM/LC/TIN
SFP/GBE/1310L/SM/LC/TIN
1550 nm types SFP/GBE/1550V/SM/LC/TIN
CWDM types SFP/2G5U/CxxxxL/SM/LC
SFP/2G5U/CxxxxV/SM/LC
SFP/4GU/CxxxxL/SM/LC
SFP/4GU/CxxxxV/SM/LC
DWDM types SFP/4GU/Dxxxx.xxV/SM/LC#Dxx on client port C1
(In bi-directional C1-NW regenerator mode
(TRANSW), only C band is supported.)
Electrical types SFP/GBE/ELECTRICAL/RJ45
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

The following table provides information about the network ports.

Table 424: Network Ports


Number of network ports 2
Data rates 4.25 Gbit/s
Protocols 4G FC transparent in C-N regenerator mode
(TRANSW mode)
proprietary in all other modes
Type of network ports SFP

The following table provides a summary of the supported network SFPs. Please
refer to the specifications of the individual SFP type.

Table 425: Supported Network SFPs


850 nm types SFP/4GU/850I/MM/LC
1310 nm types SFP/4GU/1310S/SM/LC
CWDM types SFP/4GU/CxxxxL/SM/LC
SFP/4GU/CxxxxV/SM/LC
DWDM types SFP/4GU/Dxxxx.xxV/SM/LC#Dxx

Module and System Specification 257


4TCA-PCN-4GU+4G

This table contains information about the operation modes.

Table 426: Operation Modes


Terminal multiplexer • 1 GbE/1G FC on C1, C2, C3, C4
(Protected NE and NW (HST mode)
• 2G FC on C1 and C3
or unprotected - NE or NW
(Multiplexer East/West mode)) for • 4G FC on C1
the transport of the following It is possible to mix 1 GbE and 1G FC
services: services. Services of 1 GbE, 1G FC
and 2G FC can be combined up to a
4G network stream.
Dual terminal multiplexer (2MUX) • 1 GbE/1G FC on C1, C2, C3, C4
• 2G FC on C1, C2, C3, C4
Unprotected dual terminal
multiplexer with two network ports • 4G FC on C1 and C3
equipped for the transport of the It is possible to mix 1 GbE and 1G FC
following services: services. Services of 1 GbE, 1G FC
and 2G FC can be combined up to a
4G network stream to NE and
another 4G network stream to NW.
Add/Drop Multiplexer (ADM) • 1 GbE/1G FC on C1, C2, C3, C4
Dynamic Add/Drop capability with • 2G FC on C1, C2, C3, C4
two network ports equipped of the
following services: • 4G FC on C1 and C3

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
No fixed mapping. Every service has
to be cross-connected.
It is possible to mix 1 GbE and 1G FC
services. Services of 1 GbE, 1G FC
and 2G FC can be combined up to a
4G network stream to NE and
another 4G network stream to NW.
Pass-through network to network is
not possible for 4G FC as transported
service.

Drop and Continue capability with 1 GbE towards C1, C2, C3, C4
two network ports equipped of the
following services:
Bi-directional C1-NW regenerator 4G FC on C1
(Transponder West (TRANSW)),
only C band is supported for client
and network port

258 Module and System Specification


Chapter 4 Access Type Channel Modules

This table contains information about the system performance.

Table 427: System Performance


Max. module delay in 150 ns
C-N regenerator mode
(TRANSW)
Max. module delay in 2 µs for 4G FC
all other modes 2.5 µs for 2G FC
4 µs for 1G FC, 1GbE
Number of 2 using 4TCA-PCN-4GU-4G in TRANSW mode as
regenerators transparent bidirectional single module C-N
regenerator (C1-NW).
15 using 4TCA-PCN-4GU-4G in ADM mode as
bidirectional single module N-N regenerator for
regeneration of GbE, 1G FC, 2G FC applications
multiplexed into the proprietary framed 4G signal.
Number of 15 using 4TCA-PCN-4GU-4G in dual terminal
back-to-back cascades multiplexer mode as bidirectional single module
(without protection N-N regenerator for regeneration 4G FC mapped
capability) into the proprietary framed 4G signal. In this
application the client ports 1 and 3 have to be
equipped with SFPs and connected back-to-back.
Max. frame size 9600 bytes (GbE)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

This table shows information about fault monitoring of the module in general.

Table 428: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Capability Level mismatch
Client port SFP missing;
Client port SFP mismatch;
Network port SFP missing;
Network port SFP mismatch

Module and System Specification 259


4TCA-PCN-4GU+4G

This table shows information about fault monitoring of the client ports in general.

Table 429: Fault Monitoring Client Interface - General


Physical layer Laser failure;
Laser degrade (based on bias current);
Receiver clock synch failure;
Loss of signal (LOS)

This table shows information about fault monitoring of the network ports in
general.

Table 430: Fault Monitoring Network Interface - General


Physical layer Laser failure;
Laser degrade (based on bias current);
Loss of signal (LOS)

This table shows information about fault monitoring of the network ports in
egress direction.

Table 431: Fault Monitoring Network Interface - Egress Direction


Data layer Loss of proprietary framing;
Loss of character synchronisation far end
(sub-aggregate service alarm indication);
Sub-aggregate service signal failure on link;

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Server Signal Failure of sub-aggregate service

The following table provides information about performance monitoring of the


module in general.

Table 432: Performance Monitoring - General


Equipment Module temperature (current value)
(Fix threshold crossing alert for module
temperature too high available)

This table shows information about performance monitoring of the client ports.

Table 433: Performance Monitoring Client Interface - General


Physical layer Transmitter bias current (current);
(15 min/24 h records available for PM Optical power Rx (current, low,
values except current values; mean, high);
user configurable threshold crossing alerts Optical power Tx (current, low,
for OPR too high/too low available; mean, high)
fix threshold crossing alerts for OPT too
high/too low available)

260 Module and System Specification


Chapter 4 Access Type Channel Modules

The following table gives information about performance monitoring of the client
ports in ingress direction.

Table 434: Performance Monitoring Client Interface - Ingress Direction


Data layer ES; CV; DE
(not supported in TRANSW mode)

This table shows information about performance monitoring of the network


ports.

Table 435: Performance Monitoring Network Interface - General


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high);
values except current values; Optical power Tx (current, low,
user configurable threshold crossing alerts mean, high);
for OPR too high/too low available) Transmitter bias current (current)

The following table gives information about performance monitoring of the


network ports in egress direction.

Table 436: Performance Monitoring Network Interface - Egress Direction


Data layer ES; SES; CRC errors (CRC)

This table contains information about the loop functionality.


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 437: Loop Functionality


Client ports Facility loop, Terminal loop
Network ports Facility loop, Terminal loop

The following table provides information about protection switching.

Table 438: Protection Switching


Protection scheme Versatile switched protection
(RSM-SF, RSM-OLM, VSM)
Channel protection per sub-aggregate
service (path protection)
Client channel card protection per
sub-aggregate service
Protection switching time < 50 ms
Protection switching criteria LOS;
SFP missing, mismatch;
Loss of proprietary framing;
Loss of sub-aggregate service

This table contains information about the EOC.

Table 439: Embedded Operations Channel (EOC)


Network ports Proprietary (1000 kbit/s)
(not in TRANSW mode)

Module and System Specification 261


4TCA-PCN-4GUS+4G

4TCA-PCN-4GUS+4G
The 4TCA-PCN-4GUS+4G is an access type 4-port time division multiplexing
channel module with four client and two network SFP type pluggable interfaces.
All client and network interfaces are SFP types. It supports the transport of
STM-1/OC-3, STM-4/OC-12 and GbE signal types. These applications are
multiplexed to a data rate of 4.25 Gbit/s with a proprietary protocol for
transmission at the network interfaces. The network interfaces provide channel
protection as well. The 4TCA-PCN-4GUS+4G features dynamic add/drop traffic
per client interface to multiplex and demultiplex the transmitted signal.

This module is not compatible with ITU-T G.813 and cannot be used
PS

for SDH/SONET clock distribution.


Note

Table 440 contains general information about the module and its environment.

Table 440: General Information


Equipment type 4TCA4GUS
First release 9.3
Width 4 HP
Height 5 HU

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Weight (incl. SFPs) 640 g (1.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 486,509 h
Typ. power consumption (incl. SFPs) 22 W
Max. power consumption (incl. SFPs) 25 W
Maximum RAM consumption on NCU 3,074 Kbytes
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P

The following table provides information about the client ports.

Table 441: Client Ports


Number of client ports 4
Data rates 155 Mbit/s, 622 Mbit/s, 1.25 Gbit/s,
Protocols STM-1/OC-3, STM-4/OC-12, GbE
Type of client ports SFP

262 Module and System Specification


Chapter 4 Access Type Channel Modules

The following table provides a summary of the supported client SFPs. Please
refer to the specifications of the individual SFP type.

Table 442: Supported Client SFPs


850 nm types SFP/2G1/850I/MM/LC
1310 nm types SFP/HS/1310S/SM/LC
SFP/CL/1310I/SM/LC
SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
SFP/GBE/B1310S/SM/LC
SFP/GBE/B1310L/SM/LC
1490 nm types SFP/GBE/B1490L/SM/LC
SFP/GBE/B1490S/SM/LC
CWDM types SFP/2G5U/CxxxxL/SM/LC
SFP/2G5U/CxxxxV/SM/LC
SFP/2G5U/CxxxxV/SM/LC
Electrical types SFP/GBE/ELECTRICAL/RJ45

The following table provides information about the network ports.

Table 443: Network Ports


Number of network ports 2
Data rates 4.25 Gbit/s
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Protocols proprietary
Type of network ports SFP

The following table provides a summary of the supported network SFPs. Please
refer to the specifications of the individual SFP type.

Table 444: Supported Network SFPs


850 nm types SFP/4GU/850I/MM/LC
1310 nm types SFP/4GU/1310S/SM/LC
CWDM types SFP/4GU/CxxxxL/SM/LC
SFP/4GU/CxxxxV/SM/LC
DWDM types SFP/4GU/Dxxxx.xxV/SM/LC#Dxx

Module and System Specification 263


4TCA-PCN-4GUS+4G

This table contains information about the operation modes.

Table 445: Operation Modes


Terminal multiplexer: 4x 1GbE, STM-1/OC-3, STM-4/OC-12
Protected (NE and NW) with two
network ports equipped. It is possible to mix 1GbE,
Unprotected (NE and NW) with one STM-1/OC-3 and STM-4/OC-12
network port equipped. services
Dual terminal multiplexer: 2x 2x GbE, STM-1/OC-3,
Unprotected dual terminal STM-4/OC-12
multiplexer with two network ports
equipped for the transport of the It is possible to mix 1GbE,
following services: STM-1/OC-3 and STM-4/OC-12
services
Drop and Continue multiplexer: 4x 1GbE
Drop and Continue capability with
two network ports equipped of the
following services:
Add/Drop multiplexer: • 24 x STM-1/OC-3
Dynamic Add/Drop capability with
• 18 x STM-1/OC-3 and 1 x 1GbE
two network ports equipped of the
following services: • STM-4/OC-12
• 12 x STM-1/OC-3 and 2 x 1GbE
• STM-4/OC-12

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• 6 x STM-1/OC-3 and 3 x 1GbE
• STM-4/OC-12
• 4 x 1GbE
• STM-4/OC-12

This table contains information about the system performance.

Table 446: System Performance


Max. module delay 5 µs
Number of 15 using 4TCA-PCN-4GUS-4G in ADM mode as
regenerators bidirectional single module N-N regenerator for
regeneration of the proprietary framed 4G signal.
Max. frame size 9600 bytes (GbE)

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

264 Module and System Specification


Chapter 4 Access Type Channel Modules

This table shows information about fault monitoring of the module in general.

Table 447: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Capability Level mismatch
Client port SFP missing;
Client port SFP mismatch;
Network port SFP missing;
Network port SFP mismatch

This table shows information about fault monitoring of the client ports in general.

Table 448: Fault Monitoring Client Interface - General


Physical layer Laser failure;
Laser degrade (based on bias current);
Receiver clock synch failure;
Loss of signal (LOS)

This table shows information about fault monitoring of the network ports in
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

general.

Table 449: Fault Monitoring Network Interface - General


Physical layer Laser failure;
Laser degrade (based on bias current);
Loss of signal (LOS)

This table shows information about fault monitoring of the network ports in
egress direction.

Table 450: Fault Monitoring Network Interface - Egress Direction


Data layer Loss of proprietary framing;
Loss of character synchronisation far end
(sub-aggregate service alarm indication);
Sub-aggregate service signal failure on link;
Server Signal Failure of sub-aggregate service

The following table provides information about performance monitoring of the


module in general.

Table 451: Performance Monitoring - General


Equipment Module temperature (current value)
(Fix threshold crossing alert for module
temperature too high available)

Module and System Specification 265


4TCA-PCN-4GUS+4G

This table shows information about performance monitoring of the client ports.

Table 452: Performance Monitoring Client Interface - General


Physical layer Transmitter bias current (current);
(15 min/24 h records available for PM Optical power Rx (current, low,
values except current values; mean, high);
user configurable threshold crossing alerts Optical power Tx (current, low,
for OPR too high/too low available; mean, high)
fix threshold crossing alerts for OPT too
high/too low available)

The following table gives information about performance monitoring of the client
ports in ingress direction.

Table 453: Performance Monitoring Client Interface - Ingress Direction


Data layer ES; CV; DE

This table shows information about performance monitoring of the network


ports.

Table 454: Performance Monitoring Network Interface - General


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high);
values except current values; Optical power Tx (current, low,

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
user configurable threshold crossing alerts mean, high);
for OPR too high/too low available) Transmitter bias current (current)

The following table gives information about performance monitoring of the


network ports in egress direction.

Table 455: Performance Monitoring Network Interface - Egress Direction


Data layer ES; SES; CRC errors (CRC)

This table contains information about the loop functionality.

Table 456: Loop Functionality


Client ports Facility loop, Terminal loop
Network ports Facility loop, Terminal loop

The following table provides information about protection switching.

Table 457: Protection Switching


Protection scheme Channel protection per sub-aggregate
service (path protection)
Client channel card protection per
sub-aggregate service
Protection switching time < 50 ms

266 Module and System Specification


Chapter 4 Access Type Channel Modules

Table 457: Protection Switching


Protection switching criteria LOS;
SFP missing, mismatch;
Loss of proprietary framing;
Loss of sub-aggregate service
Restoration scheme Versatile switched protection
(RSM-SF, RSM-OLM, VSM)
Restoration time <1s

This table contains information about the EOC.

Table 458: Embedded Operations Channel (EOC)


Network ports Proprietary (1000 kbit/s)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 267


WCA-PCN-2G5U

WCA-PCN-2G5U
The WCA-PCN-2G5U is a channel module with one pluggable client and two
pluggable network interfaces of SFP type. This module supports data rates of
100 Mbit/s up to 2.67 Gbit/s at the client interfaces. All services are transmitted
transparently. The module can be equipped with two network interfaces in order
to provide channel protection. The second network SFP is not necessary if
protection is not required. In addition the module can be used as bidirectional
single module N-N regenerator. In this case the client SFP may not be
equipped.
Table 459 contains general information about the module and its environment.

Table 459: General Information


Equipment type WCA2G5
First release 7.0
Width 4 HP
Height 5 HU
Weight (incl. 3 SFPs) 450 g (1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 433,839 h
Typ. power consumption (incl. SFPs) 10 W
Max. power consumption (incl. SFPs) 12 W
Maximum RAM consumption on NCU 248 Kbytes
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P

268 Module and System Specification


Chapter 4 Access Type Channel Modules

This table provides information about the client port.

Table 460: Client Port


Number of client ports 1
Data rates in fixed or adaptive discrete 125 Mbit/s, 155 Mbit/s, 200 Mbit/s,
clocked mode 622 Mbit/s, 1.0625 Gbit/s, 1.250
Gbit/s, 2.125 Gbit/s, 2.488 Gbit/s
Data rates in adaptive odd clocked 100 Mbit/s ... 2.67 Gbit/s
mode
Protocols1 ESCON, 1G FICON FCV, 1G FC,
2G FC, 1G Coupling Link, 2G
Coupling Link, FE, GbE, STM-1,
STM-4, STM-16, OC-3, OC-12,
OC-48, ATM 155, ATM 622, OTU1
Type of client ports SFP
1. SD-SDI and HD-SDI protocols for video transmission are also supported in
adaptive odd clocked mode

The following table provides a summary of the supported client SFPs. Please
refer to the specifications for the individual SFP type.

Table 461: Supported Client SFPs


850 nm types SFP/2G1/850I/MM/LC
1310 nm types SFP/HS/1310S/SM/LC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
SFP/CL/1310I/SM/LC
CWDM SFP/2G5U/CxxxxL/SM/LC
SFP/2G5U/CxxxxV/SM/LC
SFP/FE/C1510U/SM/LC
SFP/FE/C1490U/SM/LC
Electrical types SFP/GBE/ELECTRICAL/RJ45
SFP/3GSDI/ELECTRICAL/DIN1 2
SFP/3GSDI/ELECTRICAL/HBNC1 2
1. WCA-PCN-2G5U with HW rev. 2.01 required.
2. Can be used in transponder mode only.

This table contains information about the network ports.

Table 462: Network Ports


Number of network ports 2
Data rates transparent, see client port
Protocols transparent, see client port
Type of network port SFP

Module and System Specification 269


WCA-PCN-2G5U

The following table provides a summary of the supported network SFPs. Please
refer to the specifications for the individual SFP type.

Table 463: Supported Network SFPs


850 nm types SFP/2G1/850I/MM/LC
1310 nm types SFP/HS/1310S/SM/LC
SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
SFP/CL/1310I/SM/LC
CWDM types SFP/2G5U/CxxxxL/SM/LC
SFP/2G5U/CxxxxV/SM/LC
SFP/FE/C1510U/SM/LC
SFP/FE/C1490U/SM/LC
DWDM types SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx
(In amplified links the maximum input
power is reduced to -17 dBm)
SFP/3GSDI/#xxxxxV/SM/LC1 2
1. WCA-PCN-2G5U with HW rev. 2.01 required.
2. Can be used in transponder mode only.

This table contains information about the system performance.

Table 464: System Performance

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Bit Error Ratio <= 10-15 for ESCON
Max. module delay for data 10 ns
rates of 1.25 Gbit/s to 2.7 Gbit/s
Max. module delay for data 50 ns
rates up to 1.06 Gbit/s
Number of regenerations with 15 using WCA-PCN-2G5U as bidirectional
ALS disabled single module N-N regenerator.
Number of regenerations with 3 using WCA-PCN-2G5U as bidirectional
ALS enabled single module N-N regenerator
Max. frame size no limitation

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

270 Module and System Specification


Chapter 4 Access Type Channel Modules

This table shows information about fault monitoring of the module in general.

Table 465: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
Equipment fault;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Client port SFP missing;
Client port SFP mismatch;
Network port SFP missing;
Network port SFP mismatch

The following tables show information about fault monitoring.

Table 466: Fault Monitoring Client Interface - General


Physical layer Laser failure;
Laser degrade (based on bias current);
Receiver clock synch failure;
Loss of signal (LOS)

This table shows information about fault monitoring of the network ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 467: Fault Monitoring Network Interface - General


Physical layer Laser failure;
Laser degrade (based on bias current);
Receiver clock synch failure;
Loss of signal (LOS)

The following tables provide information about performance monitoring.

Table 468: Performance Monitoring - General


Equipment Module temperature (current value)
(Fix threshold crossing alert for module
temperature too high available)

Module and System Specification 271


WCA-PCN-2G5U

These tables show information about performance monitoring of the client ports.

Table 469: Performance Monitoring Client Interface - General


Physical layer Transmitter bias current
(15 min/24 h records available for PM values (current);
except current values; user configurable Optical power Rx
threshold crossing alerts for OPR too high/too low (current, low, mean, high);
available; fix threshold crossing alerts for OPT too Optical power Tx
high/too low available) (current, low, mean, high)

Table 470: Performance Monitoring Client Interface


Data layer (15 min/24 h records available) Defect seconds (DS)

These tables show information about performance monitoring of the network


ports.

Table 471: Performance Monitoring Network Interface - General


Physical layer Transmitter bias current
(15 min/24 h records available for PM values (current);
except current values; user configurable Optical power Rx
threshold crossing alerts for OPR too high/too low (current, low, mean, high);
available; fix threshold crossing alerts for OPT too Optical power Tx
high/too low available) (current, low, mean, high)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 472: Performance Monitoring Network Interface
Data layer (15 min/24 h records available) Defect seconds (DS)

The following table shows information about the loop functionality.

Table 473: Loop Functionality


Client port Facility loop
Network ports Facility loop on individual port

This table provides information about protection switching.

Table 474: Protection Switching Network Port


Protection scheme Versatile switched protection (RSM-SF,
RSM-OLM, VSM); Channel protection
Protection switching time < 50 ms
Switching criteria LOS
Max. switching time 50 ms

272 Module and System Specification


Chapter 5

Enterprise Type Channel Modules


This chapter describes enterprise type channel modules of the FSP 3000R7.
The descriptions of the discontinued enterprise type channel modules can be
found in a former version of the FSP 3000R7 Module and System Specification.
The following sections are provided:
“WCE-PCN-100GB” on p. 274
“WCE-PCN-100G” on p. 282
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

“10TCE-PCN-16GU+AES100G” on p. 290
“10TCE-PCN-10G+100G-GF” on p. 298
“10TCE-PCN-10G+100G” on p. 305
“5TCE-PCTN-10GU+10G” on p. 313
“5TCE-PCTN-10GU+AES10G” on p. 325
“5TCE-PCTN-8GU+10GS” on p. 337
“5TCE-PCTN-8GU+AES10GS” on p. 345
“5TCE-PCN-10GU+10G” on p. 354
“5TCE-PCN-10GU+AES10G” on p. 364
“4WCE-PCN-16GFC” on p. 374

Module and System Specification 273


WCE-PCN-100GB

WCE-PCN-100GB
The WCE-PCN-100GB enterprise transponder provides transport of 100 GbE
client side service in a two-slot module. The client signal is internally mapped
according to G.709 resulting in an OTU4 signal for transport over an enterprise
optical transport network.
The WCE-PCN-100GB transponder module includes a single client side inter-
face and a single network side interface with CFP MSA standard compliant
pluggable transceivers (CFP transceivers). The CFP transceivers perform the
optical-to-electrical and electrical-to-optical conversion function as well as col-
lection of all Physical Layer performance monitorings and Fault monitoring for
each optical lane. The optical performance of the client interface and the net-
work interface is specified by the equipped CFP transceiver module. See the
selected CFP transceiver module specification for additional information.
Enhanced FEC (EFEC-5) is supported on the OTU4 network port to enable
metro reach performance.
The WCE-PCN-100GB provides fault management and performance monitoring
data at the client interface as well as at the network interface for different layers.
The WCE-PCN-100GB supports Client Channel Card Protection (CCCP), 1+1
bidirectional switching.
Table 475 provides general information about the module and its environment.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 475: Module - General Information
Equipment type WCE100GB
First release 12.3
Width 8 HP
Height 5 HU
Weight 1.9 kg (4.19 lbs)
Environmental conditions Operating temperature: +5°C … +40°C
5% ... 85% relative humidity
(non-condensing)
Short-term temperature: -5°C … +40°C
5% ... 90% relative humidity
(non-condensing)
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 426,576 h
Typ. power consumption (incl. CFP 115 W
transceivers)
Max. power consumption (incl. CFP 130 W
transceivers)
Slot positions SH9HU: slots 3...17
SH1HU-HP/2DC, SH1HU-R/PF1,
SH1HU-HP/E-TEMP/2DC: slot 1
NCU types NCU-II, NCU-II-P

274 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 476 provides information about the client port.

Table 476: Client Port


Number of client ports 1
Type of client port CFP
Optical connector type LC
Data rates 103.125 Gbit/s
Protocols 100 GbE
Maximum skew 180 ns

Table 477 provides a summary of the supported client CFPs. Please refer to the
specifications for the individual CFP type.

Table 477: Supported Client CFP Types


LR4 type CFP/112G/LR4/SM/LC1
LR10 type CFP/112G/LR10R/SM/LC
SR10 type CFP/103G/SR10/MM/MPO
1. HW revision 2.01 or newer only

Table 478 provides information about the network port.

Table 478: Network Port


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Number of network ports 1


Type of network port CFP
Data rate 111.81Gbit/s
Protocol OTU4
Maximum skew 500 ns

Table 479 provides a summary of the supported network CFPs. Please refer to
the specifications for the individual CFP type.

Table 479: Supported Network CFP Types


DWDM type CFP/4x28G/#DCTL/SM/LC1
CFP/4x28G/#19xxx-#19xxxL/SM/LC2
1. 96 wavelengths in C band supported
2. 80 wavelengths in C band supported

Table 480 provides information about the 100GbE mapping.

Table 480: 100GbE Mapping


Transponder mode Client 100GbE mapped into OPU4 in accordance with
ITU-T G.709 Clause 17.7.5

Module and System Specification 275


WCE-PCN-100GB

Table 481 provides information about the module system performance.

Table 481: System Performance


Recommended max. 1 x 10-6 for low gain
pre-FEC BER for
5 x 10-5 for mid gain
EFEC-5 1
1 x 10-3 for high gain
Error coding Setting values Module delay
performance for EFEC-5 Low 4.5µs
Mid 7µs
High 10µs

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

Table 482 provides information about fault monitoring on the module equipment
level in general.

Table 482: Fault Monitoring Equipment - General


Equipment Alarm Name TL-1 Keyword
Module Equipment removed RMVD
Equipment mismatch MEA__CONDITION

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Voltage Out of Range VOLTANR
Equipment Fault HWFLT
FWP-Mismatch (NSA) FWPM-NSA
FWP-Mismatch (SA) FWPM-SA

Table 483 provides information about fault monitoring of the client ports.

Table 483: Fault Monitoring Client Interface


Layer Alarm Name TL-1 Keyword
Physical layer Laser-fail1 LASER
Laser degrade (based on bias current) LBCLANR
- applicable per optical lane
Rx Clock - Loss of Sync1 RCVCLK
Loss of signal1 LOS
CFP Removed RMVD
CFP Physical Mismatch MEA-PHYS
CFP Not Approved MEA-APPROVE
CFP Voltage Out of Range VOLTANR
CFP Incompatible MEA-ACCEPT
CFP Provision Mismatch MEA-DIFFER
Auto Shutdown-laser off LKDO-OFF

276 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 483: Fault Monitoring Client Interface (Continued)


Ethernet PCS Loss of PCS lane LOL
layer (ingress High BER HIBER
direction only) Local fault LOCAL_FAULT
Loss of character synchronization CHARSYNCH
Proprietary signal degrade SD-PCS
Auto shutdown - transmitting error LKDO-EPC
propagation code condition
1. One instance supported per optical lane as well as a single instance
supported for the aggregate status of all optical lanes.

Table 484 provides information about fault monitoring of the network interface.

Table 484: Fault Monitoring Network Interface


Layer Alarm Name TL-1 Keyword
Physical layer Laser-fail1 LASER
Laser degrade (based on bias current) LBCLANR
- applicable per optical lane
Rx Clock - Loss of Sync1 RCVCLK
Loss of signal 1 LOS
CFP Removed RMVD
CFP Physical Mismatch MEA-PHYS
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

CFP Not Approved MEA-APPROVE


CFP Voltage Out of Range VOLTANR
CFP Incompatible MEA-ACCEPT
CFP Provision Mismatch MEA-DIFFER
OPSM layer Loss of logical lane LOL
OCH layer Loss of multi-frame LOM-OTU
OTU4 layer Backward defect indication BDI-OTU
SM BIP-8 based signal degrade SD-OTU
ODU4 layer Alarm indication signal AIS-ODU
Backward defect indication BDI-ODU
Open connection indication OCI-ODU
Locked LCK-ODU
PM BIP-8 based signal degrade SD-ODU
OPU4 layer Client signal fail CSF
Payload mismatch PLM
Auto shutdown - transmitting client LKDO-CSF-OPU
signal fail
1. One instance supported per optical lane as well as a single instance
supported for the aggregate status of all optical lanes.

Module and System Specification 277


WCE-PCN-100GB

Table 485 provides information about performance monitoring of the module in


general.

Table 485: Performance Monitoring - General


Layer Alarm Name TL-1 Keyword
Equipment Module temperature - current T-TEMP-FHT
analogue value
(Fix threshold crossing alert for
module temperature too high
available)

Table 486 provides information about client service performance monitoring for
the different layers collected for both the receive direction and transmit direction.
Each of these PMs is collected for multiple instances of physical interfaces
supported by the client side CFP pluggable transceiver.

Table 486: Client Interface Performance Monitoring


Layer PM Name TL-1 Keyword
Physical layer Optical input power Rx - current, T-OPR-HT
low, mean, high T-OPR-LT
(15 min/24 h records available for
PM values except current value;
user configurable threshold

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
crossing alerts for OPR too high /
OPR too low)
Optical output power Tx - current, T-OPT-FHT
low, mean, high T-OPT-FLT
(15 min/24 h records available for
PM values except current value; fix
threshold crossing alerts for OPT
too high / OPT too low)
CFP transceiver temperature - T-TEMP-FHT
current analogue value T-TEMP-FLT
(Fix threshold crossing alert for
CFP transceiver temperature too
high/too low available)
Laser bias current level (current LBCL
analogue value)

278 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 486: Client Interface Performance Monitoring (Continued)


PCS layer - ingress Errored seconds ES
direction only (15 min/24 h records available;
user configurable threshold
crossing alerts for ES too high)
BIP8 based block errors BBE
(15 min/24 h records available;
user configurable threshold
crossing alerts for BBE too high)
Timing skew between signals in SKEW
PCS lanes (15 min/24 h records
available; user configurable
threshold crossing alerts for SKEW
too high)

Table 487 provides information about network service performance monitoring


for the different layers collected for both the receive direction and transmit
direction. Each of these PMs is collected for multiple instances of physical
interfaces supported by the network side CFP pluggable transceiver.

Table 487: Network Interface Performance Monitoring


Layer PM Name TL-1 Keyword
Physical layer Optical input power Rx - current, T-OPR-HT
low, mean, high T-OPR-LT
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

(15 min/24 h records available for


PM values except current value;
user configurable threshold
crossing alerts for OPR too high /
OPR too low)
Optical output power Tx - current, T-OPT-FHT
low, mean, high T-OPT-FLT
(15 min/24 h records available for
PM values except current value; fix
threshold crossing alerts for OPT
too high / OPT too low)
CFP transceiver T-TEMP-FHT
temperature - current analogue T-TEMP-FLT
value
(Fix threshold crossing alert for
CFP transceiver temperature too
high/too low available)
Laser bias current level (current LBCL
analogue value)

Module and System Specification 279


WCE-PCN-100GB

Table 487: Network Interface Performance Monitoring (Continued)


FEC layer FEC-corrected errors CE-FEC
(15 min/24 h records available;
user configurable threshold
crossing alerts for CE too high)
FEC-Uncorrectable block errors UBE-FEC
(15 min/24 h records available;
user configurable threshold
crossing alerts for UBE too high)
BER pre-FEC BERCE-FEC
OTU4 layer OTU-Errored Seconds ES-OTU
(15 min/24 h records available;
user configurable threshold
crossing alerts for ES too high)
OTU-Severely Errored Seconds SES-OTU
(15 min/24 h records available;
user configurable threshold
crossing alerts for SES too high)
OTU-Unavailable Seconds UAS-OTU
(15 min/24 h records available;
user configurable threshold
crossing alerts for UAS too high)
OTU-Background Block Errors BBE-OTU
(15 min/24 h records available;

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
user configurable threshold
crossing alerts for BBE too high)
OTU-Skew between Logical Lanes SKEW
(user configurable threshold
crossing alerts for SKEW too high)
ODU4 layer ODU-Errored Seconds ES-ODU
(15 min/24 h records available;
user configurable threshold
crossing alerts for ES too high)
ODU-Severely Errored Seconds SES-ODU
(15 min/24 h records available;
user configurable threshold
crossing alerts for SES too high)
ODU-Unavailable Seconds UAS-ODU
(15 min/24 h records available;
user configurable threshold
crossing alerts for UAS too high)
ODU-Background Block Errors BBE-ODU
(15 min/24 h records available;
user configurable threshold
crossing alerts for BBE too high)

280 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 488 provides information about the loop functionality.

Table 488: Loop Functionality


Client port Terminal and facility loop
Network ports Terminal and facility loop

Table 489 provides information about protection switching.

Table 489: Protection Switching


Protection scheme Client channel card protection (bidirectional
switching)
Protection switching time < 150 ms
Signal fail switching criteria CFP missing on client interface, 
CFP module mismatch on client interface,
Card failure, LOS or RCVCLK on any of the
supported optical lanes, LOL, LOM, ODU4
AIS, ODU4 OCI, ODU4 LCK, OPU4 PLM
(100GbE only), OPU4 CSF (100GbE only)
Restoration scheme Versatile switched protection (RSM-OLM,
VSM)
Restoration time1 < 5s for all services with the conditions below:
Settling time: 30 min
Minimum OSNR: 24 dB
OSNR difference between working and
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

protected path: max. 6 dB


RX input power range: +1 to -8 dB
Dispersion load: 0 ps/nm ... +/- 150 ps/nm
1. If these conditions are not met the restoration time can be up to 2 minutes.

Table 490 provides information about the Embedded Control Channels (ECCs).

Table 490: Embedded Control Channels


Notice: One GCC channel is supported per port
Client ports none
Network port GCC0 (maximum bandwidth limited to 13702
kbit/s)

Module and System Specification 281


WCE-PCN-100G

WCE-PCN-100G
The WCE-PCN-100G enterprise transponder provides transport of 100 GbE cli-
ent side service in a three-slot module. The client signal is internally mapped
according to G.709 resulting in an OTU4 signal for transport over an enterprise
optical transport network.
The WCE-PCN-100G transponder module includes a single client side interface
and a single network side interface with CFP MSA standard compliant plugga-
ble transceivers (CFP transceivers). The CFP transceivers perform the opti-
cal-to-electrical and electrical-to-optical conversion function as well as collection
of all Physical Layer performance monitorings and Fault monitoring for each
optical lane. The optical performance of the client interface and the network
interface is specified by the equipped CFP transceiver module. See the selected
CFP transceiver module specification for additional information.
Enhanced FEC (EFEC-5) is supported on the OTU4 network port to enable
metro reach performance.
The WCE-PCN-100G provides fault management and performance monitoring
data at the client interface as well as at the network interface for different layers.
The WCE-PCN-100G supports Client Channel Card Protection (CCCP), 1+1
bidirectional switching.
Table 491 provides general information about the module and its environment.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 491: Module - General Information
Equipment type WCE100G
First release 11.2
Width 12 HP
Height 5 HU
Weight 2.25 kg (4.96 lbs)
Environmental conditions Operating temperature: +5°C … +40°C
5% ... 85% relative humidity
(non-condensing)
Short-term temperature: -5°C … +45°C
5% ... 90% relative humidity
(non-condensing)
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 279,876 h
Typ. power consumption (incl. CFP 115 W
transceivers)
Max. power consumption (incl. CFP 135W
transceivers)
Slot positions Only the SH9HU, slots: 3...16
NCU types NCU-II, NCU-II-P

282 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

The following table provides information about the client port.

Table 492: Client Port


Number of client ports 1
Type of client port CFP
Optical connector type LC
Data rates 103.125 Gbit/s
Protocols 100 GbE
Maximum skew 180 ns

The following table provides a summary of the supported client CFPs. Please
refer to the specifications for the individual CFP type.

Table 493: Supported Client CFP Types


LR4 type CFP/112G/LR4/SM/LC
LR10 type CFP/112G/LR10R/SM/LC
SR10 type CFP/103G/SR10/MM/MPO

The following table provides information about the network port.

Table 494: Network Port


Number of network ports 1
Type of network port CFP
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Data rate 111.81Gbit/s


Protocol OTU4
Maximum skew 500 ns

The following table provides a summary of the supported network CFPs. Please
refer to the specifications for the individual CFP type.

Table 495: Supported Network CFP Types


DWDM type CFP/4x28G/#DCTL/SM/LC1
CFP/4x28G/#19xxx-#19xxxL/SM/LC2
1. 96 wavelengths in C band supported
2. 80 wavelengths in C band supported

The following table provides information about the 100GbE mapping.

Table 496: 100GbE Mapping


Transponder mode Client 100GbE mapped into OPU4 in accordance with
ITU-T G.709 Clause 17.7.5

Module and System Specification 283


WCE-PCN-100G

The following table provides information about the module system performance.

Table 497: System Performance


Recommended max. 1 x 10-6 for low gain
pre-FEC BER for
5 x 10-5 for mid gain
EFEC-5 1
1 x 10-3 for high gain
Error coding Setting values Module delay
performance for EFEC-5 Low 4.5µs
Mid 7µs
High 10µs

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

Table 498 provides information about fault monitoring on the module equipment
level in general.

Table 498: Fault Monitoring Equipment - General


Equipment Alarm Name TL-1 Keyword
Module Equipment removed RMVD
Equipment mismatch MEA__CONDITION

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Voltage Out of Range VOLTANR
Equipment Fault HWFLT
FWP-Mismatch (NSA) FWPM-NSA
FWP-Mismatch (SA) FWPM-SA

Table 499 provides information about fault monitoring of the client ports.

Table 499: Fault Monitoring Client Interface


Layer Alarm Name TL-1 Keyword
Physical layer Laser-fail1 LASER
Laser degrade (based on bias current) LBCLANR
- applicable per optical lane
Rx Clock - Loss of Sync1 RCVCLK
Loss of signal1 LOS
CFP Removed RMVD
CFP Physical Mismatch MEA-PHYS
CFP Not Approved MEA-APPROVE
CFP Voltage Out of Range VOLTANR
CFP Incompatible MEA-ACCEPT
CFP Provision Mismatch MEA-DIFFER
Auto Shutdown-laser off LKDO-OFF

284 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 499: Fault Monitoring Client Interface (Continued)


Ethernet PCS Loss of PCS lane LOL
layer (ingress High BER HIBER
direction only) Local fault LOCAL_FAULT
Loss of character synchronization CHARSYNCH
Proprietary signal degrade SD-PCS
Auto shutdown - transmitting error LKDO-EPC
propagation code condition
1. One instance supported per optical lane as well as a single instance
supported for the aggregate status of all optical lanes.

Table 500 provides information about fault monitoring of the network interface.

Table 500: Fault Monitoring Network Interface


Layer Alarm Name TL-1 Keyword
Physical layer Laser-fail1 LASER
Laser degrade (based on bias current) - LBCLANR
applicable per optical lane
Rx Clock - Loss of Sync1 RCVCLK
Loss of signal 1 LOS
CFP Removed RMVD
CFP Physical Mismatch MEA-PHYS
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

CFP Not Approved MEA-APPROVE


CFP Voltage Out of Range VOLTANR
CFP Incompatible MEA-ACCEPT
CFP Provision Mismatch MEA-DIFFER
OPSM layer Loss of logical lane LOL
OCH layer Loss of multi-frame LOM-OTU
OTU4 layer Backward defect indication BDI-OTU
SM BIP-8 based signal degrade SD-OTU
ODU4 layer Alarm indication signal AIS-ODU
Backward defect indication BDI-ODU
Open connection indication OCI-ODU
Locked LCK-ODU
PM BIP-8 based signal degrade SD-ODU
OPU4 layer Client signal fail CSF
Payload mismatch PLM
Auto shutdown - transmitting client LKDO-CSF-OPU
signal fail
1. One instance supported per optical lane as well as a single instance
supported for the aggregate status of all optical lanes.

Module and System Specification 285


WCE-PCN-100G

Table 501 provides information about performance monitoring of the module in


general.

Table 501: Performance Monitoring - General


Layer Alarm Name TL-1 Keyword
Equipment Module temperature - current T-TEMP-FHT
analogue value
(Fix threshold crossing alert for
module temperature too high
available)

Table 502 provides information about client service performance monitoring for
the different layers collected for both the receive direction and transmit direction.
Each of these PMs is collected for multiple instances of physical interfaces
supported by the client side CFP pluggable transceiver.

Table 502: Client Interface Performance Monitoring


Layer PM Name TL-1 Keyword
Physical layer Optical input power Rx - current, T-OPR-HT
low, mean, high T-OPR-LT
(15 min/24 h records available for
PM values except current value;
user configurable threshold

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
crossing alerts for OPR too high /
OPR too low)
Optical output power Tx - current, T-OPT-FHT
low, mean, high T-OPT-FLT
(15 min/24 h records available for
PM values except current value; fix
threshold crossing alerts for OPT
too high / OPT too low)
CFP transceiver temperature - T-TEMP-FHT
current analogue value T-TEMP-FLT
(Fix threshold crossing alert for
CFP transceiver temperature too
high/too low available)
Laser bias current level (current LBCL
analogue value)

286 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 502: Client Interface Performance Monitoring (Continued)


PCS layer - ingress Errored seconds ES
direction only (15 min/24 h records available;
user configurable threshold
crossing alerts for ES too high)
BIP8 based block errors BBE
(15 min/24 h records available;
user configurable threshold
crossing alerts for BBE too high)
Timing skew between signals in SKEW
PCS lanes (15 min/24 h records
available; user configurable
threshold crossing alerts for SKEW
too high)

Table 503 provides information about network service performance monitoring


for the different layers collected for both the receive direction and transmit
direction. Each of these PMs is collected for multiple instances of physical
interfaces supported by the network side CFP pluggable transceiver.

Table 503: Network Interface Performance Monitoring


Layer PM Name TL-1 Keyword
Physical layer Optical input power Rx - current, T-OPR-HT
low, mean, high T-OPR-LT
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

(15 min/24 h records available for


PM values except current value;
user configurable threshold
crossing alerts for OPR too high /
OPR too low)
Optical output power Tx - current, T-OPT-FHT
low, mean, high T-OPT-FLT
(15 min/24 h records available for
PM values except current value; fix
threshold crossing alerts for OPT
too high / OPT too low)
CFP transceiver T-TEMP-FHT
temperature - current analogue T-TEMP-FLT
value
(Fix threshold crossing alert for
CFP transceiver temperature too
high/too low available)
Laser bias current level (current LBCL
analogue value)

Module and System Specification 287


WCE-PCN-100G

Table 503: Network Interface Performance Monitoring (Continued)


FEC layer FEC-corrected errors CE-FEC
(15 min/24 h records available;
user configurable threshold
crossing alerts for CE too high)
FEC-Uncorrectable block errors UBE-FEC
(15 min/24 h records available;
user configurable threshold
crossing alerts for UBE too high)
pre-FEC BER BERCE-FEC
OTU4 layer OTU-Errored Seconds ES-OTU
(15 min/24 h records available;
user configurable threshold
crossing alerts for ES too high)
OTU-Severely Errored Seconds SES-OTU
(15 min/24 h records available;
user configurable threshold
crossing alerts for SES too high)
OTU-Unavailable Seconds UAS-OTU
(15 min/24 h records available;
user configurable threshold
crossing alerts for UAS too high)
OTU-Background Block Errors BBE-OTU
(15 min/24 h records available;

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
user configurable threshold
crossing alerts for BBE too high)
OTU-Skew between Logical Lanes SKEW
(user configurable threshold
crossing alerts for SKEW too high)
ODU4 layer ODU-Errored Seconds ES-ODU
(15 min/24 h records available;
user configurable threshold
crossing alerts for ES too high)
ODU-Severely Errored Seconds SES-ODU
(15 min/24 h records available;
user configurable threshold
crossing alerts for SES too high)
ODU-Unavailable Seconds UAS-ODU
(15 min/24 h records available;
user configurable threshold
crossing alerts for UAS too high)
ODU-Background Block Errors BBE-ODU
(15 min/24 h records available;
user configurable threshold
crossing alerts for BBE too high)

288 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

The following table provides information about the loop functionality.

Table 504: Loop Functionality


Client port Terminal and facility loop
Network ports Terminal and facility loop

The following table provides information about protection switching.

Table 505: Protection Switching


Protection scheme Client channel card protection (bidirectional
switching)
Protection switching time < 150 ms
Signal fail switching CFP missing on client interface, 
criteria CFP module mismatch on client interface, Card
failure, LOS or RCVCLK on any of the
supported optical lanes, LOL, LOM, ODU4 AIS,
ODU4 OCI, ODU4 LCK, OPU4 PLM (100GbE
only), OPU4 CSF (100GbE only)
Restoration scheme Versatile switched protection (RSM-OLM, VSM)
Restoration time1 < 5s for all services with the conditions below:
Settling time: 30 min
Minimum OSNR: 24 dB
OSNR difference between working and
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

protected path: max. 6 dB


RX input power range: +1 to -8 dB
Dispersion load: 0 ps/nm ... +/- 150 ps/nm
1. If these conditions are not met the restoration time can be up to 2 minutes.

The following table provides information about the Embedded Control Channels
(ECCs).

Table 506: Embedded Control Channels


Notice: One GCC channel is supported per port
Client ports none
Network port GCC0 (maximum bandwidth limited to 13702 kbit/s)

Module and System Specification 289


10TCE-PCN-16GU+AES100G

10TCE-PCN-16GU+AES100G
The 10TCE-PCN-16GU+AES100G module is a 100G enterprise type TDM
channel module with ten cages for client side SFP+ pluggable transceivers and
a single cage for a network side CFP pluggable transceiver. The module
supports encrypting of 100Gbit/s, is designed according to FIPS Publication
140-2 with security level 2, and can be used for the transport of security-related
data. The aggregated data stream is encrypted/decrypted using the Advanced
Encryption Standard (AES). Data encryption and the use of an endpoint
authentication mechanism protect the network link between two communicating
10TCE-PCN-16GU+AES100G modules against man-in-the-middle attacks.
Table 507 provides general information about the module and its environment.

Table 507: Module - General Information


Equipment type 10TCE100GAES
First release 12.3
Width 8 HP
Height 5 HU
Weight 1700 g (3.75 lbs)
Environmental conditions for ETSI EN 300 019-1-3 Class 3.1e
SH1HU-HP/2DC and Operating temperature: +5°C … +40°C
SH1HU-HP/E-TEMP/2DC 5% ... 85% relative humidity
(non-condensing)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Environmental conditions for ETSI EN 300 019-1-3 Class 3.1e
SH9HU and SH1HU-R/PF Operating temperature: +5°C … +40°C
5% ... 85% relative humidity
(non-condensing)

Short-term temperature: -5°C … +50°C


5% ... 90% relative humidity
(non-condensing)
Degree of protection according IP20. Use in a pollution degree 2
to IEC 60529 environment and indoor controlled office
environments only.
MTBF at 25°C ambient 474,042 h
temperature
Typ. power consumption 80 W
Max. power consumption 100 W
Slot positions SH9HU: slots 3...17
SH1HU-HP/2DC, SH1HU-R/PF,
SH1HU-HP/E-TEMP/2DC: slot 1
NCU types NCU-II, NCU-II-P

290 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 508 provides information about the client ports.

Table 508: Client Ports - Specifications


Number of client ports 10
Type of client port SFP+
Data rates 8.5 Gbit/s, 14.025 Gbit/s1, 10.3125 Gbit/s
Protocols 8G FC, 16G FC1, 10GbE LAN PHY, 
40GbE2, and 100GbE3
1. Client interfaces 4 through 10 only
2. 4 x 10.3125 Gbit/s on client ports C1 through C4 and C6 through C9
3. 10 x 10.3125 Gbit/s on client ports C1 through C10

Table 509 provides a summary of the supported SFP/SFP+ client transceiver


types. Please refer to the specifications for the individual SFP/SFP+ transceiver
type.

Table 509: Supported SFP/SFP+ Client Transceiver Types


850 nm types SFP+/16GFC/850I/MM/LC1
SFP+CDR/10GU/850I/MM/LC
1310 nm types SFP+/16GFC/1310S/SM/LC1
SFP+CDR/11GU/1310S/SM/LC
CWDM types SFP+CDR/11GU/CxxxxL/SM/LC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

SFP+CDR/11GU/CxxxxS/SM/LC2
1. Released for 16G FC operation only
2. Intended to be used only to connect to 40GBASE-LR4 using
J/SM/4CS-#C1270-#C1330/LC breakout cable

Table 510 provides information about the network port.

Table 510: Network Port


Number of network ports 1
Type of network ports CFP
Data rate 111.81Gbit/s
Protocol OTU4

Table 511 provides a summary of the supported CFP network transceiver types.
Please refer to the specifications for the individual CFP transceiver type.

Table 511: Supported CFP Network Transceiver Types


DWDM type CFP/4x28G/#DCTL/SM/LC1
CFP/4x28G/#19xxx-#19xxxL/SM/LC2
Grey type CFP/112G/LR10R/SM/LC
1. 96 wavelengths in C band supported
2. 80 wavelengths in C band supported

Module and System Specification 291


10TCE-PCN-16GU+AES100G

Table 512 provides information about encryption on the network port.

Table 512: Network Port - Encryption


Encryption of payload acc. Advanced Encryption Standard
with 256 bit key in counter mode
Module design acc. NIST FIPS 140-2 “Security
Requirements for Cryptographic
Modules” - security level 2
Key exchange (hardware true every 1 minute
random number generator)
Typ. initial key exchange before < 1 min
data transmission
Far-end authentication PACE protocol
Key exchange with Diffie-Hellman Diffie-Hellman group #14 from
RFC3526 with 2048 bit key length

Table 513 provides information about the operation mode and supported client
services.

Table 513: Operation Modes


Unprotected terminal Supported Services: 
multiplexer 8G FC, 16G FC, 10 GbE LAN PHY, 40 GbE and 
100 GbE
Mixture of unprotected client services supported

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 514 provides information about the mapping and multiplexing schemes.

Table 514: Mapping and Multiplexing Schemes


Client service Client services bit synchronously GMP mapped into
mapping OPUflex in accordance with ITU-T Rec. G.709 12/09
Clause 17.9; ODUflex framed
ODTU4.M mapping Client ODUflex mapped into ODTU4.M in accordance
with ITU-T Rec. G.709 Clause 19.6/ 19.6.3
Mapping of 8-bit data entities supported
ODTU4.M ODTU4.M multiplexed into OPU4 in accordance with
multiplexing ITU-T Rec. G.709 Clause 19.3.7

Table 515 provides information about the system performance.

Table 515: System Performance


Max. module delay < 8 µs for 10 GbE LAN PHY w/o FEC
< 8 µs for 8G FC/16G FC w/o FEC
< 8 µs for 40 GbE w/o FEC
< 8 µs for 100 GbE w/o FEC
EFEC transit delay penalty (to be 1 µs < penalty <6.5µs
added to transit delay without FEC)
EFEC coding gain 4.3dB < coding gain < 9.0dB
Maximum skew between individual < 70 ns
client services mapped

292 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Whether fault/performance monitoring entries listed in the

PS
following tables are applicable for a specific deployment depends
on the configuration of the respective interface.
Note

Table 516 provides information about fault monitoring on the module equipment
level in general.

Table 516: Fault Monitoring Equipment - General


Equipment Alarm Name TL-1 Keyword
Module Equipment removed RMVD
Equipment mismatch MEA-CONDITION
Voltage Out of Range VOLTANR
Equipment Fault HWFLT
FWP-Mismatch (NSA) FWPM-NSA
FWP-Mismatch (SA) FWPM-SA

Table 517 provides information about fault monitoring of the client ports.

Table 517: Fault Monitoring Client Interfaces


Layer Alarm Name TL-1 Keyword
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Physical layer Laser-fail LASER


Laser degrade (based on bias current) LBCLANR
Rx Clock - Loss of Sync RCVCLK
Loss of signal LOS
SFP+ Removed RMVD
SFP+ Physical Mismatch MEA-PHYS
SFP+ Not Approved MEA-APPROVE
SFP+ Voltage Out of Range VOLTANR
SFP+ Incompatible MEA-ACCEPT
SFP+ Provision Mismatch MEA-DIFFER
Auto Shutdown-Forward LKDO-OFF
Data rate not supported SGEO-RATE

Module and System Specification 293


10TCE-PCN-16GU+AES100G

Table 518 provides information about fault monitoring of the network port.

Table 518: Fault Monitoring Network Interface


Layer Alarm Name TL-1 Keyword
Physical layer Laser-fail1 LASER
Laser degrade (based on bias current) LBCLANR
- applicable per optical lane
Rx Clock - Loss of Sync1 RCVCLK
Loss of signal1 LOS
CFP Removed RMVD
CFP Physical Mismatch MEA-PHYS
CFP Not Approved MEA-APPROVE
CFP Voltage Out of Range VOLTANR
CFP Incompatible MEA-ACCEPT
CFP Provision Mismatch MEA-DIFFER
Auto Shutdown-laser off LKDO-OFF
Data rate not supported SGEO-RATE
OPSM layer Loss of logical lane LOL
OTU4 layer Backward defect indication BDI-OTU
ODU4 layer Alarm indication signal AIS-ODU
Open connection indication OCI-ODU

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Locked LCK-ODU
OPU layer Client signal fail CSF-OPU
Proprietary provisioning payload PPLM-OPU
mismatch
Auto shutdown - transmitting client signal LKDO-CSF
fail
1. One instance supported per optical lane as well as a single instance
supported for the aggregate status of all optical lanes.

Table 519 provides information about performance monitoring on the module


equipment level in general.

Table 519: Performance Monitoring - General


Layer PM Name TL-1 Keyword
Equipment Module temperature - current analogue T-TEMP-FHT
value
(Fix threshold crossing alert for module
temperature too high available)

294 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 520 provides information about performance monitoring values supported


on the client interfaces in ingress direction.

Table 520: Performance Monitoring Client Interface - General


Layer PM Name TL-1 Keyword
Physical layer Optical input power Rx - current, low, T-OPR-HT
mean, high T-OPR-LT
(15 min/24 h records for available for PM
values except current value; user
configurable threshold crossing alerts for
OPR too high / OPR too low)
Optical output power Tx- current, low, T-OPT-FHT
mean, high T-OPT-FLT
(15 min/24 h records for available for PM
values except current value; fix threshold
crossing alerts for OPT too high / OPT too
low)
SFP+ transceiver temperature - current T-TEMP-FHT
analogue value T-TEMP-FLT
(Fix threshold crossing alert for SFP+
transceiver temperature too high/too low
available)
Laser bias current level - current analogue LBCL
value
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 521 provides information about performance monitoring for the different
layers collected for both the receive direction and transmit direction. Each of
these PMs is collected for multiple instances of physical interfaces supported by
the network side CFP pluggable transceiver.

Module and System Specification 295


10TCE-PCN-16GU+AES100G

Table 521: Performance Monitoring Network Interface -General


Layer PM Name TL-1 Keyword
Physical layer Optical input power Rx - current, low, T-OPR-HT
mean, high  T-OPR-LT
(15 min/24 h records for available for
PM values except current value; user
configurable threshold crossing
alerts for OPR too high / OPR too
low)
Optical output power Tx - current, T-OPT-FHT
low, mean, high  T-OPT-FLT
(15 min/24 h records for available for
PM values except current value; fix
threshold crossing alerts for OPT too
high / OPT too low)
CFP transceiver temperature - T-TEMP-FHT
current analogue value T-TEMP-FLT
(Fix threshold crossing alert for
CFPtransceiver temperature too
high/too low available)
Laser bias current level - current LBCL
analogue value
FEC layer FEC-corrected errors CE-FEC
(15 min/24 h records available; user
configurable threshold crossing

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
alerts for CE too high)
FEC-Uncorrectable block errors UBE-FEC
(15 min/24 h records available; user
configurable threshold crossing
alerts for UBE too high)
pre-FEC BER BERCE-FEC
OTU4 layer OTU-Errored Seconds ES-OTU
(15 min/24 h records available; user
configurable threshold crossing
alerts for ES too high)
OTU-Severely Errored Seconds (15 SES-OTU
min/24 h records available; user
configurable threshold crossing
alerts for SES too high)
OTU-Unavailable Seconds UAS-OTU
(15 min/24 h records available; user
configurable threshold crossing
alerts for UAS too high)
OTU-Background Block Errors BBE-OTU
(15 min/24 h records available; user
configurable threshold crossing
alerts for BBE too high)
OTU-Skew between Logical Lanes SKEW
(user configurable threshold crossing
alerts for SKEW too high)

296 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 522 information about performance monitoring for encryption.

Table 522: Performance Monitoring for Encryption


15 min/24 h records encryption running
encryption running in “degraded mode”
encryption not running
time stamp last successful key exchange
last failed key exchange
last change of Crypto-Officer password
last failed Crypto-Officer password
timer (countdown) remaining session- key lifetime
remaining time running in bypass mode

Table 523 provides information about the loop functionality.

Table 523: Loop Functionality


Client ports Terminal and facility loopback

Table 524 provides information about protection setting.

Table 524: Protection Switching


Restoration scheme Versatile switched protection (RSM-OLM, VSM)
Restoration time 1 < 1s for all services with the conditions below:
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Settling time: 30 min


Minimum OSNR: 24 dB
OSNR difference between working and
protected path: max. 6 dB
RX input power range: +1 to -8 dB
Dispersion load: 0 ps/nm ... +/- 150 ps/nm
1. If these conditions are not met the restoration time can be up to 2 minutes.

Table 525 provides information about the Embedded Control Channels (ECCs).

Table 525: Embedded Control Channels


Notice: One GCC channel is supported per port
Client ports none
Network port GCC0 (maximum bandwidth limited to 13702 kbit/s)

Module and System Specification 297


10TCE-PCN-10G+100G-GF

10TCE-PCN-10G+100G-GF
The 10TCE-PCN-10G+100G-GF is a 100G enterprise type TDM channel
module with ten SFP+ interfaces on the client side (10x10G) and a single CFP
interface on the network side. This module supports ODU4 according to ITU-T
G.709 with reduced functionality, ODUflex and GMP. It can map combinations
of up to ten 10Gbit/s client signals into an OTU4 interface. The aggregate 100G
service signal (OTU4) is transmitted at a data rate of 111.81Gbit/s using the
multi-lane concept according to the above-mentioned standard. G.709 standard
FEC (GFEC) is provided on the network interface. 
The 10TCE-PCN-10G+100G-GF supports versatile switched protection.
Performance monitoring and fault management of physical layer alarms and
service-related alarms are also supported.
Table 526 provides general information about the module and its environment.

Table 526: Module - General Information


Equipment type 10TCE100G
First release 11.2
Width 8 HP
Height 5 HU
Weight 1700 g (3.748lbs)
Environmental conditions Operating temperature: +5°C...+40°C
5% ... 85% relative humidity

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
(non-condensing)
Short-term temperature1: -5°C...+50°C
5% ... 90% relative humidity
(non-condensing)
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient 307,314 h
temperature
Typ. power consumption (incl. 80 W
pluggable transceivers)
Max. power consumption (incl. 100 W
pluggable transceivers)
Slot positions SH9HU: slots 3...17
SH1HU-HP/2DC, SH1HU-R/PF,
SH1HU-HP/E-TEMP/2DC: slot 1
NCU types NCU-II, NCU-II-P
1. The maximum short-term temperature in an SH1HU-HP/2DC is restricted to
45°C.

The following table provides information about the client ports.

Table 527: Client Ports


Number of client ports 10
Type of client port SFP+

298 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 527: Client Ports (Continued)


Data rates 8.5000Gbit/s, 9.9532Gbit/s, 10.3125 Gbit/s,
Protocols 8G FC, 10GbE LAN PHY, 10GbE WAN PHY,
STM-64, OC-192

The following table provides a summary of the supported SFP+ client trans-
ceiver types. Please refer to the specifications for the individual SFP+ trans-
ceiver type.

Table 528: Supported SFP+ Client Transceiver Types


850 nm types SFP+/11GU/850I/MM/LC
SFP+CDR/10GU/850I/MM/LC
1310 nm types SFP+/11GU/1310S/SM/LC
SFP+CDR/11GU/1310S/SM/LC
1550 nm types SFP+CDR/10GU/1550L/SM/LC

The following table provides information about the network port.

Table 529: Network Port


Number of network ports 1
Type of network ports CFP
Data rate 111.81Gbit/s
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Protocol OTU4
Maximum skew 500 ns

The following table provides a summary of the supported CFP network trans-
ceiver types. Please refer to the specifications for the individual CFP transceiver
type.

Table 530: Supported CFP Network Transceiver Types


DWDM type CFP/4x28G/#DCTL/SM/LC1
CFP/4x28G/#19xxx-#19xxxL/SM/LC2
Gray type CFP/112G/LR10R/SM/LC
1. 96 wavelengths in C band supported
2. 80 wavelengths in C band supported

The following table provides information about the operation modes and sup-
ported client services.

Table 531: Operation Modes


Unprotected terminal Supported Services:
multiplexer 8G FC, 10GbE LAN PHY, 10GbE WAN PHY,
STM64/ OC192, 
Mixture of unprotected client services supported

Module and System Specification 299


10TCE-PCN-10G+100G-GF

Table below provides information about the mapping and multiplexing schemes.

Table 532: Mapping and Multiplexing Schemes


Client service Client services bit synchronously GMP mapped into
mapping OPUflex in accordance with ITU-T Rec. G.709 12/09
Clause 17.9; ODUflex framed
ODTU4.ts mapping Client ODUflex mapped into ODTU4.ts in accordance
with ITU-T Rec. G.709 Clause 19.6/ 19.6.3
Mapping of 8-bit data entities supported
ODTU4.ts ODTU4.ts multiplexed into OPU4 in accordance with
multiplexing ITU-T Rec. G.709 Clause 19.3.7

The following table provides information about the system performance.

Table 533: System Performance


Recommended maximum pre FEC bit 5 x 10-5
error ratio for GFEC
Module delay < 8.5µs
Max. frame size for 10GbE services 9216 bytes

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Note

The following table provides information about fault monitoring on the module
equipment level in general.

Table 534: Fault Monitoring Module - General


Equipment Module removed
Module mismatch
Module voltage abnormal
General hardware fault
Module temperature alarm
Firmware package mismatch NSA
Firmware package mismatch SA
Client port SFP+ removed
Client port SFP+ voltage abnormal
Client port SFP+ not accepted
Client port SFP+ physical mismatch
Client port SFP+ not approved
Client port SFP+ provisioning mismatch
Client port SFP+ temperature
Network port CFP removed
Network port CFP voltage abnormal
Network port CFP not accepted
Network port CFP physical mismatch
Network port CFP not approved
Network port CFP provisioning mismatch
Network port CFP temperature

300 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

The following table provides information about fault monitoring of the client ports
in ingress direction.

Table 535: Fault Monitoring Client Interface - Ingress Direction


Physical layer Loss of signal (LOS);
Receiver clock loss (RCVCLK)
Data rate not supported (SGEO-RATE)

The following table provides information about fault monitoring of the client ports
in egress direction.

Table 536: Fault Monitoring Client Interface - Egress Direction


Physical layer Laser failure (LASER)
Laser bias current abnormal (LBCLANR)
Autonomous shutdown - laser off (LKDO-OFF)

The following table provides information about fault monitoring of the network
interface in ingress direction. All conditions applying to the physical layer
including the TCA on the performance of the optical lanes will be reported N
times 
(N = number of physical interfaces on the pluggable CFP transceiver module).

Table 537: Fault Monitoring Network Interface - Ingress Direction


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Physical layer Optical power received too low with configurable


threshold (T-OPR-LT) - applicable per optical lane
Optical power received too high with configurable
threshold (T-OPR-HT) - applicable per optical lane
Receiver clock loss (RCVCLK)
Loss of signal (LOS) - applicable per optical lane
Data rate not supported (SGEO-RATE)
OTN layer Loss of logical lane (LOL)
Loss of frame (LOF)
Backward defect indication (BDI)
Alarm indication signal condition (AIS)
Open connection indication condition (OCI)
Locked condition (LCK)

The following table provides information about fault monitoring of the network
interface in egress direction. All conditions applying to the physical layer includ-
ing the TCA on the performance of the optical lanes will be reported N times (N
= number of physical interfaces on the pluggable CFP transceiver module).

Module and System Specification 301


10TCE-PCN-10G+100G-GF

Table 538: Fault Monitoring Network Interface - Egress Direction


Physical layer Laser failure (LASER) - applicable per optical lane
Optical power transmit too high with fix threshold
(T-OPT-FHT) - applicable per optical lane
Laser bias current abnormal (LBCLANR) - applicable per
optical lane
Optical power transmit too low with fix threshold
(T-OPT-FLT) - applicable per optical lane
OTN layer Autonomous shutdown - transmitting client signal fail
(LKDO-CSF)

The following table provides information about performance monitoring on the


module equipment level in general.

Table 539: Performance Monitoring Module - General


Equipment Module temperature - current analogue value
(with fix threshold crossing alert for module temperature
too high)
SFP+ transceiver temperature - current analogue value
(with fix threshold crossing alert for SFP+ transceiver
temperature too high/too low TCA thresholds)
CFP transceiver temperature - current analogue value
(with fix threshold crossing alert for CFP transceiver

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
temperature too high/too low TCA thresholds)

The following table provides information about performance monitoring values


supported on the client interfaces in ingress direction.

Table 540: Client Interface Ingress Performance Monitoring


Physical layer Optical input power Rx (OPR) -
(15 min/24 h records for OPR values current, low, mean and high
available; user configurable threshold value
crossing alerts for OPR too high/too low
available)

The following table provides information about performance monitoring values


supported on the client interfaces in egress direction.

Table 541: Client Interface Egress Performance Monitoring


Physical layer Optical output power Tx (OPT) -
(15 min/24 h records for PM values current, low, mean, high
available; fix threshold crossing alerts for Laser bias current level - current
OPT too high/too low available analogue value (LBCL)
LBCL current value TCA
LBCL too high TCA threshold
LBCL too high TCA threshold
(LBCL) crossed condition

302 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

The following table provides information about performance monitoring values


supported on the network interface in ingress direction.

Table 542: Network Interface Ingress Performance Monitoring


Physical layer Optical input power Rx (OPR) -
(15 min/24 h records for OPR values current, low, mean, high
available; user configurable threshold
crossing alerts for OPR too high & too low
available)
FEC layer CE; UBE; BERCE
(15min/24h records for these PM values
including user configurable threshold
crossing alerts are available)
OTU4 layer ES; SES; UAS; BBE; SKEW1
(15min/24h records for these PM values
including user configurable threshold
crossing alerts are available)
1. The TCA on the measured skew can be set up to 1000ns to allow customers
to operate the module outside its specified operational range on their own
risk and still set the TCA such that no alarm is raised under the extended
operational conditions. To prevent a TCA to be raised if the user just uses
the default value for the TCA threshold it is set to its outer value range.

The following table provides information about performance monitoring values


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

supported on the network interface in egress direction.

Table 543: Network Interface Egress Performance Monitoring


Physical layer Optical output power Tx (OPT) -
(15 min/24 h records for PM values current, low, mean, high
available; fix threshold crossing alerts for Laser bias current level - current
OPT too high/too low available) analogue value (LBCL)
LBCL current value TCA
LBCL too high TCA threshold
LBCL too high TCA threshold
(LBCL) crossed condition

The following table provides information about the loop functionality.

Table 544: Loop Functionality


Client ports Terminal loop on individual port
Facility loop on individual port
Network port Terminal loop

The following table provides information about protection switching.

Table 545: Protection Switching


Restoration scheme Versatile switched protection (RSM-OLM, VSM)

Module and System Specification 303


10TCE-PCN-10G+100G-GF

Table 545: Protection Switching (Continued)


Restoration time1 < 1 s for all services with the conditions below:
Settling time: 30 min
Minimum OSNR: 24 dB
OSNR difference between working and
protected path: max. 6 dB
RX input power range: +1 to -8 dB
Dispersion load: 0 ps/nm ... +/- 150 ps/nm
1. If these conditions are not met the restoration time can be up to 1 minute.

The following table provides information about the Embedded Control Channels
(ECCs).

Table 546: Embedded Control Channels


NOTICE: One GCC channel is supported per port
Client ports none
Network port GCC0 (maximum bandwidth limited to 1312kbit/s)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

304 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

10TCE-PCN-10G+100G
The 10TCE-PCN-10G+100G is a 100G enterprise type TDM channel module
with ten SFP+ interfaces on the client side (10x10G) and a single CFP interface
on the network side. This module supports ODU4 according to ITU-T G.709 with
reduced functionality, ODUflex and GMP. It can map combinations of up to ten
10Gbit/s client signals into an OTU4 interface. The aggregate 100G service sig-
nal (OTU4) is transmitted at a data rate of 111.81Gbit/s using the multi-lane con-
cept according to the above-mentioned standard. Enhanced FEC (EFEC-5)
optimized for minimum latency is provided on the network interface. 
Performance monitoring and fault management of physical layer alarms and
service-related alarms are supported.
Table 547 provides general information about the module and its environment.

Table 547: Module - General Information


Equipment type 10TCE100G
First release 11.2
Width 8 HP
Height 5 HU
Weight 1700 g (3.748lbs)
Environmental conditions Operating temperature: +5°C...+40°C
5% ... 85% relative humidity
(non-condensing)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Short-term temperature1: -5°C...+50°C


5% ... 90% relative humidity
(non-condensing)
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient 307,314 h
temperature
Typ. power consumption (incl. 80 W
pluggable transceivers)
Max. power consumption (incl. 100 W
pluggable transceivers)
Slot positions SH9HU: slots 3...17
SH1HU-HP/2DC, SH1HU-R/PF,
SH1HU-HP/E-TEMP/2DC: slot 1
NCU types NCU-II, NCU-II-P
1. The max. short-term temperature in an SH1HU-HP/2DC is restricted to 45°C.

The following table provides information about the client ports.

Table 548: Client Ports


Number of client ports 10
Type of client port SFP+

Module and System Specification 305


10TCE-PCN-10G+100G

Table 548: Client Ports (Continued)


Data rates 8.5000Gbit/s, 9.9532Gbit/s, 10.3125 Gbit/s
Protocols 8G FC, 10GbE LAN PHY, 10GbE WAN PHY,
STM-64, OC-192

Table below provides a summary of the supported SFP+ client transceiver


types. Please refer to the specifications for the individual SFP+ transceiver type.

Table 549: Supported SFP+ Client Transceiver Types


850 nm types SFP+/11GU/850I/MM/LC
SFP+CDR/10GU/850I/MM/LC
1310 nm types SFP+/11GU/1310S/SM/LC
SFP+CDR/11GU/1310S/SM/LC
1550 nm types SFP+CDR/10GU/1550L/SM/LC

The following table provides information about the network port.

Table 550: Network Port


Number of network ports 1
Type of network ports CFP
Data rate 111.81Gbit/s
Protocol OTU4

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Maximum skew 500 ns

Table below provides a summary of the supported CFP network transceiver


types. Please refer to the specifications for the individual CFP transceiver type.

Table 551: Supported CFP Network Transceiver Types


DWDM type CFP/4x28G/#DCTL/SM/LC1
CFP/4x28G/#19xxx-#19xxxL/SM/LC2
Gray type CFP/112G/LR10R/SM/LC
1. 96 wavelengths in C band supported
2. 80 wavelengths in C band supported

The following table provides information about the operation modes and sup-
ported client services.

Table 552: Operation Modes


Unprotected terminal Supported Services: 8G FC, 10GbE LAN PHY, 10GbE
multiplexer WAN PHY, STM64/ OC192, Mixture of unprotected
client services supported

306 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table below provides information about the mapping and multiplexing schemes.

Table 553: Mapping and Multiplexing Schemes


Client service Client services bit synchronously GMP mapped into
mapping OPUflex in accordance with ITU-T Rec. G.709 12/09
Clause 17.9; ODUflex framed
ODTU4.ts mapping Client ODUflex mapped into ODTU4.ts in accordance
with ITU-T Rec. G.709 Clause 19.6/ 19.6.3
Mapping of 8-bit data entities supported
ODTU4.ts ODTU4.ts multiplexed into OPU4 in accordance with
multiplexing ITU-T Rec. G.709 Clause 19.3.7

The following table provides information about the system performance.

Table 554: System Performance


Recommended max. pre-FEC BER 1 x 10-6 for low gain
for EFEC-5
5 x 10-5 for mid gain
1 x 10-3 for high gain
Error coding performance for Setting values Module delay
EFEC-5 Low 9 µs
Mid 12 µs
High 15 µs
Max. frame size for 10GbE services 9216 bytes
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

Module and System Specification 307


10TCE-PCN-10G+100G

The following table provides information about fault monitoring on the module
equipment level in general.

Table 555: Fault Monitoring Module - General


Equipment Module removed
Module mismatch
Module voltage abnormal
General hardware fault
Module temperature alarm
Firmware package mismatch NSA
Firmware package mismatch SA
Client port SFP+ removed
Client port SFP+ voltage abnormal
Client port SFP+ not accepted
Client port SFP+ physical mismatch
Client port SFP+ not approved
Client port SFP+ provisioning mismatch
Client port SFP+ temperature
Network port CFP removed
Network port CFP voltage abnormal
Network port CFP not accepted
Network port CFP physical mismatch
Network port CFP not approved
Network port CFP provisioning mismatch
Network port CFP temperature

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table provides information about fault monitoring of the client ports
in ingress direction.

Table 556: Fault Monitoring Client Interface - Ingress Direction


Physical layer Loss of signal (LOS);
Receiver clock loss (RCVCLK)
Data rate not supported (SGEO-RATE)

The following table provides information about fault monitoring of the client ports
in egress direction.

Table 557: Fault Monitoring Client Interface - Egress Direction


Physical layer Laser failure (LASER)
Laser bias current abnormal (LBCL)
Autonomous shutdown - laser off (LKDO-OFF)

308 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

The following table provides information about fault monitoring of the network
interface in ingress direction. All conditions applying to the physical layer includ-
ing the TCA on the performance of the optical lanes will be reported N times (N
= number of physical interfaces on the pluggable CFP transceiver module).

Table 558: Fault Monitoring Network Interface - Ingress Direction


Physical layer Optical power received too low with configurable
threshold (T-OPR-LT) - applicable per optical lane
Optical power received too high with configurable
threshold (T-OPR-HT) - applicable per optical lane
Receiver clock loss (RCVCLK)
Loss of signal (LOS) - applicable per optical lane
Data rate not supported (SGEO-RATE)
OTN layer Loss of logical lane (LOL)
Loss of frame (LOF)
Backward defect indication (BDI)
Alarm indication signal condition (AIS)
Open connection indication condition (OCI)
Locked condition (LCK)

The following table provides information about fault monitoring of the network
interface in egress direction. All conditions applying to the physical layer includ-
ing the TCA on the performance of the optical lanes will be reported N times (N
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

= number of physical interfaces on the pluggable CFP transceiver module).

Table 559: Fault Monitoring Network Interface - Egress Direction


Physical layer Laser failure (LASER) - applicable per optical lane
Optical power transmit too high with fix threshold
(T-OPT-FHT) - applicable per optical lane
Laser bias current abnormal (LBCLANR) - applicable per
optical lane
Optical power transmit too low with fix threshold
(T-OPT-FLT) - applicable per optical lane
OTN layer Autonomous shutdown - transmitting client signal fail
(LKDO-CSF)

Module and System Specification 309


10TCE-PCN-10G+100G

The following table provides information about performance monitoring on the


module equipment level in general.

Table 560: Performance Monitoring Module - General


Equipment Module temperature - current analogue value
(with fix threshold crossing alert for module temperature
too high)
SFP+ transceiver temperature - current analogue value
(with fix threshold crossing alert for SFP+ transceiver
temperature too high/too low TCA thresholds)
CFP transceiver temperature - current analogue value
(with fix threshold crossing alert for CFP transceiver
temperature too high/too low TCA thresholds)

The following table provides information about performance monitoring values


supported on the client interfaces in ingress direction.

Table 561: Client Interface Ingress Performance Monitoring


Physical layer Optical input power Rx (OPR) -
(15 min/24 h records for OPR values current, low, mean, high
available; user configurable threshold
crossing alerts for OPR too high/too low
available)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table provides information about performance monitoring values
supported on the client interfaces in egress direction.

Table 562: Client Interface Egress Performance Monitoring


Physical layer Optical output power Tx (OPT) -
(15 min/24 h records for PM values current, low, mean, high
available; fix threshold crossing alerts for Laser bias current level - current
OPT too high/too low available) analogue value (LBCL)
LBCL current value TCA
LBCL too high TCA threshold
LBCL too high TCA threshold
(LBCL) crossed condition

310 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

The following table provides information about performance monitoring values


supported on the network interface in ingress direction.

Table 563: Network Interface Ingress Performance Monitoring


Physical layer Optical input power Rx (OPR) -
(15 min/24 h records for OPR values current, low, mean, high
available; user configurable threshold
crossing alerts for OPR too high & too low
available)
FEC layer CE; UBE; BERCE
(15min/24h records for these PM values
including user configurable threshold
crossing alerts are available)
OTU4 layer ES; SES; UAS; BBE; SKEW1
(15min/24h records for these PM values
including user configurable threshold
crossing alerts are available)
1. The TCA on the measured skew can be set up to 1000ns to allow customers
to operate the module outside its specified operational range on their own
risk and still set the TCA such that no alarm is raised under the extended
operational conditions. To prevent a TCA to be raised if the user just uses
the default value for the TCA threshold it is set to its outer value range.

The following table provides information about performance monitoring values


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

supported on the network interface in egress direction.

Table 564: Network Interface Egress Performance Monitoring


Physical layer Optical output power Tx (OPT) -
(15 min/24 h records for PM values current, low, mean, high
available; fix threshold crossing alerts for Laser bias current level - current
OPT too high/too low available) analogue value (LBCL)
LBCL current value TCA
LBCL too high TCA threshold
LBCL too high TCA threshold
(LBCL) crossed condition

The following table provides information about the loop functionality.

Table 565: Loop Functionality


Client ports Terminal loop on individual port
Facility loop on individual port
Network port Terminal loop

The following table provides information about protection switching.

Table 566: Protection Switching


Restoration scheme Versatile switched protection (RSM-OLM, VSM)

Module and System Specification 311


10TCE-PCN-10G+100G

Table 566: Protection Switching (Continued)


Restoration time1 < 1 s for all services with the conditions below:
Settling time: 30 min
Minimum OSNR: 24 dB
OSNR difference between working and
protected path: max. 6 dB
RX input power range: +1 to -8 dB
Dispersion load: 0 ps/nm ... +/- 150 ps/nm
1. If these conditions are not met the restoration time can be up to 1 minute.

The following table provides information about the Embedded Control Channels
(ECCs).

Table 567: Embedded Control Channels


NOTICE: One GCC channel is supported per port
Client ports none
Network port GCC0 (maximum bandwidth limited to 1312kbit/s)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

312 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

5TCE-PCTN-10GU+10G
The 5TCE-PCTN-10GU+10G module is a 5-port TDM channel module with
pluggable client interfaces and one DWDM network interface.
The module can operate in three different modes:
• TDM mode
o
Transparent multiplexer mode: 
The incoming data stream is mapped bit for bit in a simplified G.709
frame. The client ports support 1G FC, 2G FC, 4G FC, 5G IB and 1GbE.
The data rate on the network port depends on the application. Transport
of 5G IB services is supported in the TDM mode multiplexing up to 2 x
5G IB. 5G IB transport requires the use of the appropriate SFP+ devices
in the client interfaces C1 and C2.
o Framed mode: 
In framed mode the physical coding sublayer (PCS) is terminated. The
8B/10B coding is removed prior to multiplexing. Rate adaption is
performed through byte stuffing. The client ports support 1G FC, 2G FC,
4G FC, 8G FC and 1GbE. 8G FC can be applied at client port 1 only.
• Transparent transponder mode:
This mode is similar to the transparent multiplexer mode, but it allows to
transport 8G FC, 10G FC, 10GbE LAN and 10G IB as single service only
applied at client port 1.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

The 5TCE-PCTN-10GU+10G is available in three variants:


• 5TCE-PCTN-10GU+10G-LN#DC
• 5TCE-PCTN-10GU+10G-V#DC
• 5TCE-PCTN-10GU+10G-V#DL
The 5TCE-PCTN-10GU+10G-V#DC and 5TCE-PCTN-10GU+10G-V#DL have
very long reach network interfaces. The 5TCE-PCTN-10GU+10G-LN#DC
features a long reach noise optimized network interface, which has a high
extinction ratio suitable for links with a large amount of amplifiers and low
OSNR.
Table 568 contains general information about the module and its environment.

Table 568: Module - General Information for all Variants


Equipment type 5TCE10GT-D
First release 9.3
MTBF at 25°C ambient 262,395 h
temperature
Typ. power consumption 30 W in TDM mode
26 W in transponder mode
Max. power consumption 42 W
Maximum RAM consumption 763 Kbytes
on NCU
Width 4 HP
Height 5 HU
Weight 725 g (1.6 lbs)

Module and System Specification 313


5TCE-PCTN-10GU+10G

Table 568: Module - General Information for all Variants (Continued)


Environmental conditions for Telcordia SR-3580 level 3 (NEBS), ETSI
SH9HU EN 300 019-1-3 Class 3.1
Environmental conditions for Operating temperature: +5°C … +40°C
SH7HU, SH7HU-R, SH1HU-R, 5% ... 85% relative humidity
SH1HU-F/2DC, (non-condensing)
SH1HU-HP/2DC,
SH1HU-HP/E-TEMP/2DC Short-term temperature: -5°C … +45°C
5% ... 90% relative humidity
(non-condensing)
Environmental conditions for Operating temperature: +5°C … +40°C
SH1HU-R/PF 5% ... 85% relative humidity
(non-condensing)

Short-term temperature: -5°C … +55°C


5% ... 90% relative humidity
(non-condensing)
Degree of protection according IP20. Use in a pollution degree 2
to IEC 60529 environment and indoor controlled office
environments only.
Slot positions SH9HU: slots 3...18
SH7HU, SH7HU-R: slots 3...18
SH1HU: slots 1, 2
NCU types NCU, NCU-II, NCU-II-P

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table provides information about the client ports for all variants.

Table 569: Client Ports - Specifications for all Variants


Number of client ports 5
Optical connector type LC
Type of client ports SFP (client port 1 to 5)
SFP+ (client ports 1 and 2 only)
Data rates (transparent transponder 8.5 Gbit/s, 10.51875 Gbit/s, 
mode), client port C1 only 10.313 Gbit/s, 10 Gbit/s
Data rates (transparent multiplexer 1.250 Gbit/s, 1.0625 Gbit/s, 
mode) 2.125 Gbit/s, 4.250 Gbit/s
Data rates (transparent multiplexer 5.0 Gbit/s
mode), client port C1 and C2 only
Data rates (framed mode) 1.250 Gbit/s, 1.0625 Gbit/s, 
2.125 Gbit/s, 4.250 Gbit/s
Data rates (framed mode), client 8.5 Gbit/s
port C1 only
Protocols (transparent transponder 8G FC, 10G FC, 10 GbE LAN PHY, 
mode) 10G IB, ITU-T G.8262 and IEEE 1588v2
compliant transparent Ethernet
transport

314 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 569: Client Ports - Specifications for all Variants


Protocols (transparent multiplexer GbE, 1G FC, 2G FC (incl. 2G Coupling
mode) Link), 4G FC, 5G IB, ITU-T G.8262 and
IEEE 1588v2 compliant transparent
Ethernet transport
Protocols (framed mode) GbE, 1G FC, 2G FC, 4G FC, 8G FC

This table provides a summary of the supported client SFPs. Please refer to the
specifications for the individual SFP type.
Table 570: Supported Client SFPs for all Variants
850 nm types SFP/2G1/850I/MM/LC
SFP/4GU/850I/MM/LC
SFP+/8GU/850I/MM/LC (client port 1)
SFP+/10G/850I/MM/LC (client ports 1 and 2)
SFP+/11GU/850I/MM/LC
1310 nm types SFP/HS/1310S/SM/LC
SFP/CL/1310I/SM/LC
SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
SFP/4GU/1310S/SM/LC
SFP+/8GU/1310S/SM/LC (client port 1)
SFP+/10G/1310S/SM/LC (client ports 1 and 2)
SFP+/11GU/1310S/SM/LC
SFP/GBE/B1310S/SM/LC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

SFP/GBE/B1310L/SM/LC
1490 nm types SFP/GBE/B1490L/SM/LC
SFP/GBE/B1490S/SM/LC

Module and System Specification 315


5TCE-PCTN-10GU+10G

The following table provides information about the network port for all variants.,
Table 571: Network Port - General Information for all Variants
Number of network ports 1
Type of network port Tunable DWDM interface
Optical connector type LC
Fiber type SM 9 µm
Data rates 10.9747 Gbit/s for 8G FC,
(transparent transponder mode) 10.7595 Gbit/s for 10G IB,
11.0957Gbit/s for 10 GbE,
11.3176 Gbit/s for 10G FC
Data rates (Multiplexer mode, transparent as 11.3176 Gbit/s
well as framed)
Protocols Subset G.709 OTU2
Tuning time (any channel to any ch.) < 45 s
Tuning time cold start (any channel to any < 60 s
channel)
Max. shuttered output power (dark tuning) -30 dBm

The following table provides information about the network port for the
5TCE-PCTN-10GU-LN#DC.

Table 572: Network Port - Optical Performance for


5TCE-PCTN-10GU-LN#DC

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmitter output power range -3 dBm ... 0 dBm
Transmitter wavelength range 81 channels, 50 GHz spacing in C
band acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 60 pm
Min. extinction ratio 11 dB at 10.7595 Gbit/s
10 dB at 11.3176 Gbit/s
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -14 dBm ... -1 dBm
Receiver dynamic range for operation -16 dBm ...-1 dBm
with FEC starting Rel. 10.2
OPR measurement range -18 dBm ... +2 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range -300 ps/nm ... +300 ps/nm
Dispersion load range with 1 dB -500 ps/nm ... -300 ps/nm and 
OSNR penalty +300 ps/nm ... +500 ps/nm
Dispersion load range with 2 dB -700 ps/nm ... -500 ps/nm and 
OSNR penalty +500 ps/nm ... +700 ps/nm
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)
OSNR penalty at -16 dBm Rx input 1 dB
power for operation without FEC or
with FEC up to Rel. 10.2

316 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 572: Network Port - Optical Performance for


5TCE-PCTN-10GU-LN#DC (Continued)
OSNR penalty at -18 dBm Rx input 1 dB
power for operation with FEC starting
Rel. 10.2
OSNR penalty at 10.9747 Gbit/s, 1 dB
11.0957Gbit/s and 11.3176 Gbit/s

This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-10GU-LN#DC.

Table 573: Bit Error Rate Versus OSNR for 5TCE-PCTN-10GU-LN#DC


Bit Error Ratio for operation w/o FEC < 10-12 at 23 dB OSNR at 0.1 nm
Pre-FEC Bit Error Ratio for operation < 10-9 at 19 dB OSNR at 0.1 nm
with FEC starting Rel. 10.2 (ATC)
< 10-5 at 15 dB OSNR at 0.1 nm
Pre-FEC Bit Error Ratio for operation < 10-9 at 21 dB OSNR at 0.1 nm
with FEC up to Rel. 10.2 (w/o ATC)
< 10-5 at 17 dB OSNR at 0.1 nm

The following table provides information about the network port for the
5TCE-PCTN-10GU+10G-V#DC.

Table 574: Network Port - Optical Performance for


5TCE-PCTN-10GU+10G-V#DC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Transmitter output power range +4 dBm ... +6 dBm


Transmitter wavelength range 81 channels, 50 GHz spacing in C band
acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 60 pm
Min. extinction ratio 10 dB
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -20 dBm ... -8 dBm
OSNR penalty at -22 dBm Rx input 1 dB
power
OPR measurement range -22 dBm ... -5 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range +200 ps/nm ... +800 ps/nm
Dispersion load range with 1dB -100 ps/nm ... +200 ps/nm and 
OSNR penalty +800 ps/nm ... +1100 ps/nm
Dispersion load range with 2dB -400 ps/nm ... -100 ps/nm and 
OSNR penalty +1100 ps/nm ... +1400 ps/nm
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)
OSNR penalty at 10.9747 Gbit/s, 1 dB
11.0957Gbit/s and 11.3176 Gbit/s

Module and System Specification 317


5TCE-PCTN-10GU+10G

This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-10GU+10G-V#DC.

Table 575: Bit Error Rate Versus OSNR for 5TCE-PCTN-10GU+10G-V#DC


Pre-FEC Bit Error Ratio < 10-12 at 25 dB OSNR at 0.1 nm
< 10-9 at 23 dB OSNR at 0.1 nm
< 10-5 at 19 dB OSNR at 0.1 nm

The following table provides information about the network port for the
5TCE-PCTN-10GU+10G-V#DL.

Table 576: Network Port - Optical Performance for


5TCE-PCTN-10GU+10G-V#DL
Transmitter output power range +3 dBm ... +5 dBm
Transmitter wavelength range 41 channels, 100 GHz spacing in the 
L band acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 100 pm
Min. extinction ratio 10 dB
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -20 dBm ... -8 dBm
OSNR penalty at -22 dBm Rx input 1 dB
power

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
OPR measurement range -22 dBm ... -5 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range +200 ps/nm ... +800 ps/nm
Dispersion load range with 1dB -100 ps/nm ... +200 ps/nm and 
OSNR penalty +800 ps/nm ... +1100 ps/nm
Dispersion load range with 2dB -400 ps/nm ... -100 ps/nm and 
OSNR penalty +1100 ps/nm ... +1400 ps/nm
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)
OSNR penalty at 10.9747 Gbit/s, 1 dB
11.0957Gbit/s and 11.3176 Gbit/s

This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-10GU+10G-V#DL.
Table 577: Bit Error Rate Versus OSNR for 5TCE-PCTN-10GU+10G-V#DL
Pre-FEC Bit Error Ratio < 10-12 at 25 dB OSNR at 0.1 nm
< 10-9 at 23 dB OSNR at 0.1 nm
< 10-5 at 19 dB OSNR at 0.1 nm

To achieve a post-FEC BER better than 10-12, ADVA Optical


Networking recommends operating the network port of the
PS

module at pre-FEC BER values not higher than stated in the


Note following table.

318 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

This table shows the recommended maximum pre-FEC bit error ratio for all
variants.

Table 578: Recommended Maximum Pre-FEC BER for all Variants


GFEC 1 x 10-5
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 319


5TCE-PCTN-10GU+10G

The following table provides information about the operation modes for all
variants.

Table 579: Operation Modes for all Variants


Transparent transponder 8G FC, 10G FC, 10GbE LAN and 
mode (single service) 10G IB as single service only
Transparent multiplexer Support of 12 virtual containers (VC).
mode Number of concatenated VCs needed:
1GbE = 2 VC 
(starting at VC number 1 through 11 only)

1G FC = 2 VC
(starting at VC number 1 through 11 only)

2G FC = 3 VC
(starting at VC number 1 through 10 only)

4G FC = 5 VC
(starting at VC number 1 through 8 only)

5G IB = 6VC
(starting at VC number 1, 7 only)
Framed mode Support of 12 virtual containers (VC).
Number of concatenated VCs needed:
1G FC = 1 VC

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
(starting at every VC number possible)

2G FC or 1GbE = 2 VC
(starting at VC number 1, 3, 5, 7, 9, 11 only)

4G FC = 4 VC
(starting at VC number 1, 5, 9 only)

8G FC = 8 VC
(starting at VC number 1, 5 only)
Mapping / Framing Mapping into proprietary used 
OPU2 / ODU2 framing acc. to ITU-T G.709.
Max. frame size for 
FC services < 2200 bytes
GbE services 9600 bytes

The virtual containers required for an individual service have to be


PS

concatenated. In addition there is a restriction of the starting virtual


container in framed mode as stated in the table above.
Note

This table contains information about the system performance for all variants.

320 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 580: System Performance for all Variants


Max. module delay in 1G FC: 5 µs without FEC / 10 µs with FEC
transparent multiplexer 2G FC: 3.5 µs without FEC / 8.5 µs with FEC
mode and transparent 4G FC: 2.5 µs without FEC / 7.5 µs with FEC
transponder mode 8G FC: 1.5 µs without FEC / 7 µs with FEC
10G FC: 1.5 µs without FEC / 7 µs with FEC
GbE: 5 µs without FEC / 10 µs with FEC
10 GbE LAN PHY and 10G IB: 
1.5 µs without FEC / 7 µs with FEC
5G IB: 2.5 µs without FEC / 8 µs with FEC
Max. module delay in 1G FC: 7.5 µs without FEC / 13 µs with FEC
framed mode 2G FC: 4.5 µs without FEC / 10 µs with FEC
4G FC: 3 µs without FEC / 8 µs with FEC
8G FC: 2.3 µs without FEC / 7.5 µs with FEC
GbE: 6 µs without FEC / 11 µs with FEC
Number of back-to-back 3 using 5TCE-PCTN-10GU+10G
cascades (without
protection capability)
Number of regenerators 2 using 2WCA-PCN-10G as bidirectional single
module C-N regenerator using
XFP/11G/Dxxxx.xxV/SM/LC#Dxx and
XFP/11G/DCTV/SM/LC supporting data rates
between 9.9532 Gbit/s and 11.3176 Gbit/s at a
max. ambient temperature of 45°C1
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

1. In this application the 2WCA-PCN-10G has to be provisioned to a data rate


between 9.9532 Gbit/s and 10.709 Gbit/s even if the transported data rate is
higher.

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

This table shows information about fault monitoring of the module in general for
all variants.

Table 581: Fault Monitoring - General for all Variants


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Capability level mismatch;
Client port SFP missing;
Client port SFP mismatch;
Latency (low, high)

Module and System Specification 321


5TCE-PCTN-10GU+10G

This table shows information about fault monitoring of the client ports in general
for all variants.

Table 582: Fault Monitoring Client Interface - General for all Variants
Physical layer Laser failure;
Laser degrade (based on bias current);
Loss of signal (LOS)

This table shows information about fault monitoring of the client ports in ingress
direction for all variants.

Table 583: Fault Monitoring Client Interface - Ingress Direction for all
Variants
Physical coding sublayer (PCS) Loss of character synchronization1
1. Only supported in framed mode.

This table shows information about fault monitoring of the network ports for all
variants.

Table 584: Fault Monitoring Network Interface - General for all Variants
Physical layer Laser failure;
Receiver clock synch failure;
Loss of signal (LOS)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table provides information about fault monitoring of the network ports in
egress direction for all variants.

Table 585: Fault Monitoring Network Interface - Egress Direction for all
Variants
OCH/OTU2 layer LOF
OPU2 layer AIS
Proprietary aggregate VF layer SSF-VF; AIS-VF

The following table provides information about performance monitoring of the


module in general for all variants.

Table 586: Performance Monitoring - General for all Variants


Equipment Module temperature (current value)
(with fix threshold crossing alert for
module temperature too high)

322 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

This table shows information about performance monitoring of the client ports
for all variants.

Table 587: Performance Monitoring Client Interface - Ingress Direction for all
Variants
Physical layer Transmitter bias current
(15 min/24 h records available for PM values (current); Optical power
except current values; user configurable threshold Rx (current, low, mean,
crossing alerts for OPR too high/too low available; high); Optical power Tx
fix threshold crossing alerts for OPT too high/too (current, low, mean, high);
low available) Latency (current, low,
mean, high)
Physical coding sublayer CV; DE; ES1
(15 min/24 h records with user configurable
threshold crossing alerts available)
1. CV, DE and ES - only supported in framed mode

This table shows information about performance monitoring of the network ports
for all variants.

Table 588: Performance Monitoring Network Interface - General for all


Variants
Physical layer Optical power Rx
(15 min/24 h records available for PM values (current, low, mean,
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

except current values; user configurable threshold high),


crossing alerts for OPR too high/too low available) Optical power Tx
fix threshold crossing alerts for OPT too high/too (current, low, mean, high)
low available) Latency (current, low,
mean, high)

The following table gives information about performance monitoring of the


network ports in egress direction.

Table 589: Performance Monitoring Network Interface - Egress Direction for


all Variants
OTU2 layer - SM byte ES; SES; UAS; BBE
(15 min/24 h records with user configurable
threshold crossing alerts available)
FEC layer CE; UBE; ES; SES; BERCE
(15 min/24 h records with user configurable
threshold crossing alerts available)

This table provides information about the loop functionality for all variants.

Table 590: Loop Functionality for all Variants


Client ports Facility loop on individual port,
Terminal loop on individual port
Network port Facility loop, Terminal loop

Module and System Specification 323


5TCE-PCTN-10GU+10G

This table shows information about protection setting for all variants.

Table 591: Protection Switching for all Variants


Protection scheme Versatile switched protection
(RSM-SF, RSM-OLM, VSM)
Client channel card protection
Protection switching time < 50 ms
Signal fail switching criteria LOS; SSF-VF; AIS-VF; AIS-OPU;
physical Client SFP removed; Tx failure on
client interface

This table contains information about the Embedded Controlled Channels


(ECCs) for all variants.

Table 592: Embedded Control Channels for all Variants


Notice: One GCC channel is supported per port
Client ports none
Network port GCC0 (1312 kbit/s)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

324 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

5TCE-PCTN-10GU+AES10G
The 5TCE-PCTN-10GU+AES10G module is a 5-port TDM channel module with
five pluggable client interfaces and one DWDM network interface supporting
data encryption. The module is designed according to FIPS Publication 140-2
with security level 2, and can be used for the transport of security-related data.
The aggregated data stream is encrypted/decrypted using the Advanced
Encryption Standard (AES). Data encryption and the use of an endpoint
authentication mechanism protect the network link between two communicating
5TCE-PCTN-10GU+AES10G modules against man-in-the-middle attacks.
The module can operate in following modes:
• TDM mode
o Transparent multiplexer mode: 
The incoming data stream is mapped bit for bit in a simplified G.709
frame. The client ports support 1G FC, 2G FC, F2488, 4G FC, 5G IB
and 1GbE. The data rate on the network port depends on the
application. Transport of 5G IB services is supported in the TDM mode
multiplexing up to 2 x 5G IB. 5G IB transport requires the use of the
appropriate SFP+ devices in the client interfaces C1 and C2.
o Framed mode: 
In framed mode the physical coding sublayer (PCS) is terminated. The
8B/10B coding is removed prior to multiplexing. Rate adaption is
performed through byte stuffing. The client ports support 1G FC, 2G FC,
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

4G FC, 8G FC and 1GbE. 8G FC can be applied at client port 1 only.


• Transparent transponder mode:
This mode is similar to the transparent multiplexer mode, but it allows to
transport 8G FC, F9953, 10G FC, 10GbE LAN and 10G IB as single service
only applied at client port 1.
The 5TCE-PCTN-10GU+AES10G is available in three variants:
• 5TCE-PCTN-10GU+AES10G-LN#DC
• 5TCE-PCTN-10GU+AES10G-V#DC
• 5TCE-PCTN-10GU+AES10G-V#DL
5TCE-PCTN-10GU+AES10G-V#DC and 5TCE-PCTN-10GU+AES10G-V#DL
have very long reach network interfaces.
The 5TCE-PCTN-10GU+AES10G-LN#DC features a long reach noise
optimized network interface, which has a high extinction ratio suitable for links
with a large amount of amplifiers and low OSNR.

Module and System Specification 325


5TCE-PCTN-10GU+AES10G

Table 593 contains general information about the module and its environment.

Table 593: Module - General Information for all Variants


Equipment type 5TCE10GTAES-D
First release 10.3
MTBF at 25°C ambient 344,482 h for
temperature 5TCE-PCTN-10GU+AES10G-LN#DC
269,336 h for
5TCE-PCTN-10GU+AES10G-V#DC
308,337 h for
5TCE-PCTN-10GU+AES10G-V#DL
Typ. power consumption 32 W in TDM mode
28 W in transponder mode
Max. power consumption 45 W
Width 4 HP
Height 5 HU
Weight 725 g (1.6 lbs)
Environmental conditions for Telcordia SR-3580 level 3 (NEBS), ETSI
SH9HU EN 300 019-1-3 Class 3.1
Environmental conditions for Operating temperature: +5°C … +40°C
SH7HU, SH7HU-R, SH1HU-R, 5% ... 85% relative humidity
SH1HU-F/2DC, (non-condensing)
SH1HU-HP/2DC,

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SH1HU-HP/E-TEMP/2DC Short-term temperature: -5°C … +45°C
5% ... 90% relative humidity
(non-condensing)
Environmental conditions for Operating temperature: +5°C … +40°C
SH1HU-R/PF 5% ... 85% relative humidity
(non-condensing)

Short-term temperature: -5°C … +55°C


5% ... 90% relative humidity
(non-condensing)
Degree of protection according IP20. Use in a pollution degree 2
to IEC 60529 environment and indoor controlled office
environments only.
Slot positions SH9HU: slots 3...18
SH7HU, SH7HU-R: slots 3...18
SH1HU: slots 1, 2
NCU types NCU-II, NCU-II-P

The following table provides information about the client ports for all variants.

Table 594: Client Ports - Specifications for all Variants


Number of client ports 5
Optical connector type LC
Type of client ports SFP (client port 1 to 5)
SFP+ (client ports 1 and 2 only)

326 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 594: Client Ports - Specifications for all Variants (Continued)


Data rates (transparent 8.5 Gbit/s, 9.953 Gbit/s,10.51875 Gbit/s,
transponder mode), client port 10.313 Gbit/s, 10.0 Gbit/s
C1 only
Data rates (transparent 1.250 Gbit/s, 1.0625 Gbit/s, 2.125 Gbit/s,
multiplexer mode) 2.48832 Gbit/s, 4.250 Gbit/s
Data rates (transparent 5.0 Gbit/s
multiplexer mode), client port C1
and C2 only
Data rates (framed mode) 1.250 Gbit/s, 1.0625 Gbit/s, 2.125 Gbit/s,
4.250 Gbit/s
Data rates (framed mode), client 8.5 Gbit/s
port C1 only
Protocols (transparent 8G FC, F9953, 10G FC, 10 GbE LAN PHY,
transponder mode) 10G IB, ITU-T G.8262 and IEEE 1588v2
compliant transparent Ethernet transport
Protocols (transparent GbE, 1G FC, 2G FC (incl. 2G Coupling
multiplexer mode) Link), F2488, 4G FC, 5G IB, ITU-T G.8262
and IEEE 1588v2 compliant transparent
Ethernet transport
Protocols (framed mode) GbE, 1G FC, 2G FC, 4G FC, 8G FC

This table provides a summary of the supported client SFPs. Please refer to the
specifications for the individual SFP type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 595: Supported Client SFPs for all Variants


850 nm types SFP/2G1/850I/MM/LC
SFP/4GU/850I/MM/LC
SFP+/8GU/850I/MM/LC (client port 1)
SFP+/10G/850I/MM/LC (client ports 1 and 2)
SFP+/11GU/850I/MM/LC
1310 nm types SFP/HS/1310S/SM/LC
SFP/CL/1310I/SM/LC
SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
SFP/4GU/1310S/SM/LC
SFP+/8GU/1310S/SM/LC (client port 1)
SFP+/10G/1310S/SM/LC (client ports 1 and 2)
SFP+/11GU/1310S/SM/LC

The following table provides information about the network port for all variants.

Table 596: Network Port - General Information for all Variants


Number of network ports 1
Type of network port Tunable DWDM interface
Optical connector type LC
Fiber type SM 9 µm

Module and System Specification 327


5TCE-PCTN-10GU+AES10G

Table 596: Network Port - General Information for all Variants (Continued)
Data rates 10.9747 Gbit/s for 8G FC,
(transparent transponder mode) 10.7092 Gbit/s for F9953,
10.7595 Gbit/s for 10G IB,
11.0957Gbit/s for 10 GbE,
11.3176 Gbit/s for 10G FC
Data rates 11.3176 Gbit/s
(Multiplexer mode, transparent as
well as framed)
Protocols Subset G.709 OTU2
Tuning time (any channel to any ch.) < 45 s
Tuning time cold start (any channel < 60 s
to any channel)
Maximum shuttered output power -30 dBm
(dark tuning)

Table below provides information about encryption on the network port for all
variants.
Table 597: Network Port - Encryption for all Variants
Encryption of payload acc. Advanced Encryption Standard
with 256 bit key in counter mode
Module design acc. NIST FIPS 140-2 “Security
Requirements for Cryptographic
Modules” - security level 2

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Key exchange (hardware true every 10 minutes
random number generator)
Typ. initial key exchange before < 3 min
data transmission
Far-end authentication PACE protocol
Key exchange with Diffie-Hellman Diffie-Hellman group #5 from RFC3526
with 1536 bit key length

The following table provides information about the network port for the
5TCE-PCTN-10GU+AES10G-LN#DC.

Table 598: Network Port - Optical Performance for


5TCE-PCTN-10GU+AES10G-LN#DC
Transmitter output power range -3 dBm ... 0 dBm
Transmitter wavelength range 81 channels, 50 GHz spacing in C
band acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 60 pm
Min. extinction ratio 11 dB at 10.7595 Gbit/s
10 dB at 11.3176 Gbit/s
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range for operation -14 dBm ... -1 dBm
without FEC
Receiver dynamic range for operation -16 dBm ...-1 dBm
with FEC

328 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 598: Network Port - Optical Performance for


5TCE-PCTN-10GU+AES10G-LN#DC (Continued)
OPR measurement range -18 dBm ... +2 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range -300 ps/nm ... +300 ps/nm
Dispersion load range with 1dB OSNR -500 ps/nm ... -300 ps/nm and 
penalty +300 ps/nm ... +500 ps/nm
Dispersion load range with 2dB OSNR -700 ps/nm ... -500 ps/nm and 
penalty +500 ps/nm ... +700 ps/nm
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)
OSNR penalty at -16 dBm Rx input 1 dB
power
OSNR penalty at -18 dBm Rx input 1 dB
power for operation with FEC
OSNR penalty at 10.9747 Gbit/s, 1 dB
11.0957Gbit/s and 11.3176 Gbit/s

This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-10GU+AES10G-LN#DC.

Table 599: Bit Error Rate Versus OSNR for 5TCE-PCTN-10GU-LN#DC


Bit Error Ratio for operation w/o FEC < 10-12 at 23 dB OSNR at 0.1 nm
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Pre-FEC Bit Error Ratio for operation < 10-9 at 19 dB OSNR at 0.1 nm
with FEC
< 10-5 at 15 dB OSNR at 0.1 nm

The following table provides information about the network port for the
5TCE-PCTN-10GU+AES10G-V#DC.

Table 600: Network Port - Optical Performance for


5TCE-PCTN-10GU+AES10G-V#DC
Transmitter output power range +4 dBm ... +6 dBm
Transmitter wavelength range 81 channels, 50 GHz spacing in C band
acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 60 pm
Min. extinction ratio 10 dB
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -20 dBm ... -8 dBm
OSNR penalty at -22 dBm Rx input 1 dB
power
OPR measurement range -22 dBm ... -5 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range +200 ps/nm ... +800 ps/nm
Dispersion load range with 1dB -100 ps/nm ... +200 ps/nm and 
OSNR penalty +800 ps/nm ... +1100 ps/nm
Dispersion load range with 2dB -400 ps/nm...-100 ps/nm and 
OSNR penalty +1100 ps/nm... +1400 ps/nm

Module and System Specification 329


5TCE-PCTN-10GU+AES10G

Table 600: Network Port - Optical Performance for


5TCE-PCTN-10GU+AES10G-V#DC (Continued)
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)
OSNR penalty at 10.9747 Gbit/s, 1 dB
11.0957Gbit/s and 11.3176 Gbit/s

This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-10GU+AES10G-V#DC.

Table 601: Bit Error Rate Versus OSNR for


5TCE-PCTN-10GU+AES10G-V#DC
Pre-FEC Bit Error Ratio < 10-12 at 25 dB OSNR at 0.1 nm
< 10-9 at 23 dB OSNR at 0.1 nm
< 10-5 at 19 dB OSNR at 0.1 nm

The following table provides information about the network port for the
5TCE-PCTN-10GU+AES10G-V#DL.

Table 602: Network Port - Optical Performance for


5TCE-PCTN-10GU+AES10G-V#DL
Transmitter output power range +3 dBm ... +5 dBm
Transmitter wavelength range 41 channels, 100 GHz spacing in the L

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
band acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 100 pm
Min. extinction ratio 10 dB
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -20 dBm ... -8 dBm
OSNR penalty at -22 dBm Rx input 1 dB
power
OPR measurement range -22 dBm ... -5 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range +200 ps/nm ... +800 ps/nm
Dispersion load range with 1dB -100 ps/nm ... +200 ps/nm and 
OSNR penalty +800 ps/nm ... +1100 ps/nm
Dispersion load range with 2dB -400 ps/nm ... -100 ps/nm and 
OSNR penalty +1100 ps/nm ... +1400 ps/nm
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)
OSNR penalty at 10.9747 Gbit/s, 1 dB
11.0957Gbit/s and 11.3176 Gbit/s

330 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-10GU+AES10G-V#DL.

Table 603: Bit Error Rate Versus OSNR for


5TCE-PCTN-10GU+AES10G-V#DL
Pre-FEC Bit Error Ratio < 10-12 at 25 dB OSNR at 0.1 nm
< 10-9 at 23 dB OSNR at 0.1 nm
< 10-5 at 19 dB OSNR at 0.1 nm

To achieve a post-FEC BER better than 10-12, ADVA Optical


Networking recommends operating the network port of the
PS

module at pre-FEC BER values not higher than stated in the


Note following table.

This table shows the recommended maximum pre-FEC bit error ratio for all
variants.

Table 604: Recommended Maximum Pre-FEC BER for all Variants


GFEC 1 x 10-5
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 331


5TCE-PCTN-10GU+AES10G

Table below provides information about the operation modes for all variants.

Table 605: Operation Modes for all Variants


Transparent transponder mode 8G FC, F9953, 10G FC, 10GbE LAN and
10G IB as single service only
Transparent multiplexer mode Support of 12 virtual containers (VC).
Number of concatenated VCs needed:
1GbE = 2 VC 
(starting at VC number 1 through 11 only)

1G FC = 2 VC
(starting at VC number 1 through 11 only)

2G FC, F2488 = 3 VC
(starting at VC number 1 through 10 only)

4G FC = 5 VC
(starting at VC number 1 through 8 only)

5G IB = 6VC
(starting at VC number 1, 7 only)
Framed mode Support of 12 virtual containers (VC).
Number of concatenated VCs needed:
1G FC = 1 VC
(starting at every VC number possible)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
2G FC or 1GbE = 2 VC
(starting at VC number 1, 3, 5, 7, 9, 11 only)
4G FC = 4 VC
(starting at VC number 1, 5, 9 only)
8G FC = 8 VC
(starting at VC number 1, 5 only)
Mapping / Framing Mapping into proprietary used 
OPU2 / ODU2 framing acc. to ITU-T G.709.
Max. frame size for 
FC services < 2200 bytes
GbE services 9600 bytes

The virtual containers required for an individual service have to be


PS

concatenated. In addition there is a restriction of the starting virtual


container in framed mode as stated in the table above.
Note

332 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

This table contains information about the system performance for all variants.

Table 606: System Performance for all Variants


Max. module delay in 1G FC: 5 µs without FEC / 10 µs with FEC
transparent multiplexer 2G FC: 3.5 µs without FEC / 8.5 µs with FEC
mode and transparent F2488: 3.5 µs without FEC / 8.5 µs with FEC
transponder mode 4G FC: 2.5 µs without FEC / 7.5 µs with FEC
8G FC: 1.5 µs without FEC / 7 µs with FEC
10G FC: 1.5 µs without FEC / 7 µs with FEC
GbE: 5 µs without FEC / 10 µs with FEC
F9953: 1.5 µs without FEC / 7 µs with FEC
10 GbE LAN PHY and 10G IB: 
1.5 µs without FEC / 7 µs with FEC
5G IB: 2.5 µs without FEC / 8 µs with FEC
Max. module delay in 1G FC: 7.5 µs without FEC / 13 µs with FEC
framed mode 2G FC: 4.5 µs without FEC / 10 µs with FEC
4G FC: 3 µs without FEC / 8 µs with FEC
8G FC: 2.3 µs without FEC / 7.5 µs with FEC
GbE: 6 µs without FEC / 11 µs with FEC
Number of back-to-back 3 using 5TCE-PCTN-10GU+AES10G
cascades (without
protection capability)
Number of regenerators 2 using 2WCA-PCN-10G as bidirectional single
module C-N regenerator using
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

XFP/11G/Dxxxx.xxV/SM/LC#Dxx and
XFP/11G/DCTV/SM/LC supporting data rates
between 9.9532 Gbit/s and 11.3176 Gbit/s at a
max. ambient temperature of 45°C1
1. In this application the 2WCA-PCN-10G has to be provisioned to a data rate
between 9.9532 Gbit/s and 10.709 Gbit/s even if the transported data rate is
higher.

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

This table shows information about fault monitoring of the module in general for
all variants.

Table 607: Fault Monitoring - General for all Variants


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Capability level mismatch;
Client port SFP missing;
Client port SFP mismatch;
Latency (low, high)

Module and System Specification 333


5TCE-PCTN-10GU+AES10G

This table shows information about fault monitoring of the client ports in general
for all variants.

Table 608: Fault Monitoring Client Interface - General for all Variants
Physical layer Laser failure;
Laser degrade (based on bias current);
Loss of signal (LOS)

This table shows information about fault monitoring of the client ports in ingress
direction for all variants.

Table 609: Fault Monitoring Client Interface - Ingress Direction for all
Variants
Physical coding sublayer (PCS) Loss of character synchronization1
1. Only supported in framed mode.

This table shows information about fault monitoring of the network ports for all
variants.

Table 610: Fault Monitoring Network Interface - General for all Variants
Physical layer Laser failure;
Receiver clock synch failure;
Loss of signal (LOS)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table provides information about fault monitoring of the network ports in
egress direction for all variants.

Table 611: Fault Monitoring Network Interface - Egress Direction for all
Variants
OCH/OTU2 layer LOF
OPU2 layer AIS
Proprietary aggregate VF layer SSF-VF; AIS-VF

The following table provides information about performance monitoring of the


module in general for all variants.

Table 612: Performance Monitoring - General for all Variants


Equipment Module temperature (current value)
(with fix threshold crossing alert for
module temperature too high)

334 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

This table shows information about performance monitoring of the client ports
for all variants.

Table 613: Performance Monitoring Client Interface - Ingress Direction for all
Variants
Physical layer Transmitter bias current
(15 min/24 h records available for PM values (current); Optical power
except current values; user configurable threshold Rx (current, low, mean,
crossing alerts for OPR too high/too low available; high); Optical power Tx
fix threshold crossing alerts for OPT too high/too (current, low, mean, high);
low available) Latency (current, low,
mean, high)
Physical coding sublayer CV; DE; ES1
(15 min/24 h records with user configurable
threshold crossing alerts available)
1. CV, DE and ES - only supported in framed mode

This table shows information about performance monitoring of the network ports
for all variants.

Table 614: Performance Monitoring Network Interface - General for all


Variants
Physical layer Optical power Rx
(15 min/24 h records available for PM values (current, low, mean,
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

except current values; user configurable threshold high),


crossing alerts for OPR too high/too low available) Optical power Tx
fix threshold crossing alerts for OPT too high/too (current, low, mean, high)
low available) Latency (current, low,
mean, high)

The following table gives information about performance monitoring of the


network ports in egress direction.

Table 615: Performance Monitoring Network Interface - Egress Direction for


all Variants
OTU2 layer - SM byte ES; SES; UAS; BBE
(15 min/24 h records with user configurable
threshold crossing alerts available)
FEC layer CE; UBE; ES; SES; BERCE
(15 min/24 h records with user configurable
threshold crossing alerts available)

Module and System Specification 335


5TCE-PCTN-10GU+AES10G

The following table gives information about performance monitoring for


encryption.

Table 616: Performance Monitoring - Encryption for all Variants


15 min/24 h records encryption running
encryption running in “degraded mode”
encryption not running
time stamp last successful key exchange
last failed key exchange
last change of Crypto-Officer password
last failed Crypto-Officer password
timer (countdown) remaining session- key lifetime
remaining time running in bypass mode

This table provides information about the loop functionality for all variants.

Table 617: Loop Functionality for all Variants


Client ports Facility loop on individual port,
Terminal loop on individual port
Network port Facility loop, Terminal loop 
(Facility and terminal loop on the
network port is only allowed for bypass
applications when encryption is
disabled.)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table shows information about protection setting for all variants.

Table 618: Protection Switching for all Variants


Protection scheme Client channel card protection
Protection switching time < 50 ms
Signal fail switching criteria LOS; SSF-VF; AIS-VF; AIS-OPU;
physical Client SFP removed; Tx failure on
client interface
Restoration scheme Versatile switched protection
(RSM-SF, RSM-OLM, VSM)
Restoration time <500 ms

This table contains information about the Embedded Controlled Channels


(ECCs) for all variants.

Table 619: Embedded Control Channels for all Variants


Notice: One GCC channel is supported per port
Client ports none
Network port GCC0 (1312 kbit/s)

336 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

5TCE-PCTN-8GU+10GS
The 5TCE-PCTN-8GU+10GS module is a 5-port TDM channel module with five
pluggable client interfaces and one DWDM network interface.
The module can operate in following TDM modes:
• Transparent multiplexer mode: 
The incoming data stream is physically terminated and mapped bit for bit
into VC4-64c or STS192c payload, and then mapped into STM64 or OC192
framing structure with reduced functionality according to ITU-T G.707 or
Telcordia GR-253. The client ports support 1G FC, 2G FC, 4G FC and
1GbE.
• Framed mode: 
In framed mode the physical coding sublayer (PCS) is terminated. The
8B/10B coding is removed prior to multiplexing. Rate adaption is performed
through byte stuffing. The client ports support 1G FC, 2G FC, 4G FC, 8G FC
and 1GbE. 8G FC can be applied at client port 1 only.
The 5TCE-PCTN-8GU+10GS is available in two variants:
• 5TCE-PCTN-8GU+10GS-LN#DC
• 5TCE-PCTN-8GU+10GS-V#DC
The 5TCE-PCTN-8GU+10GS-V#DC has very long reach network interfaces.
The 5TCE-PCTN-8GU+10GS-LN#DC features a long reach noise optimized
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

network interface, which has a high extinction ratio suitable for links with a large
amount of amplifiers and low OSNR.
Table 620 contains general information about the module and its environment.

Table 620: Module - General Information for all Variants


Equipment type 5TCES10GT-D
First release 11.1
MTBF at 25°C ambient 233,770 h
temperature
Typ. power consumption 30 W
Max. power consumption 42 W
Width 4 HP
Height 5 HU
Weight 725 g (1.6 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS), ETSI EN
for SH9HU 300 019-1-3 Class 3.1
Environmental conditions Operating temperature: +5°C … +40°C
for SH7HU, SH7HU-R, 5% ... 85% relative humidity (non-condensing)
SH1HU-R, SH1HU-F/2DC,
SH1HU-HP/2DC, Short-term temperature: -5°C … +45°C
SH1HU-HP/E-TEMP/2DC 5% ... 90% relative humidity (non-condensing)

Module and System Specification 337


5TCE-PCTN-8GU+10GS

Table 620: Module - General Information for all Variants (Continued)


Environmental conditions Operating temperature: +5°C … +40°C
for SH1HU-R/PF 5% ... 85% relative humidity (non-condensing)

Short-term temperature: -5°C … +55°C


5% ... 90% relative humidity (non-condensing)
Degree of protection IP20. Use in a pollution degree 2 environment
according to IEC 60529 and indoor controlled office environments only.
Slot positions SH9HU: slots 3...18
SH7HU, SH7HU-R: slots 3...18
SH1HU: slots 1, 2
NCU types NCU-II, NCU-II-P

The following table provides information about the client ports for all variants.

Table 621: Client Ports - Specifications for all Variants


Number of client ports 5
Optical connector type LC
Type of client ports SFP (client ports 1 to 5)
SFP+ (client port 1 only)
Data rates (transparent multiplexer 1.250 Gbit/s, 1.0625 Gbit/s, 
mode) 2.125 Gbit/s, 4.250 Gbit/s
Data rates (framed mode) 1.250 Gbit/s, 1.0625 Gbit/s, 
2.125 Gbit/s, 4.250 Gbit/s

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Data rates (framed mode), client 8.5 Gbit/s
port C1 only
Protocols (transparent multiplexer GbE, 1G FC, 2G FC (incl. 2G Coupling
mode) Link), 4G FC
Protocols (framed mode) GbE, 1G FC, 2G FC, 4G FC, 8G FC

This table provides a summary of the supported client SFPs. Please refer to the
specifications for the individual SFP type.
Table 622: Supported Client SFPs for all Variants
850 nm types SFP/2G1/850I/MM/LC
SFP/4GU/850I/MM/LC
SFP+/8GU/850I/MM/LC (client port 1)
SFP+/11GU/850I/MM/LC
1310 nm types SFP/HS/1310S/SM/LC
SFP/CL/1310I/SM/LC
SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
SFP/4GU/1310S/SM/LC
SFP+/8GU/1310S/SM/LC (client port 1)
SFP+/11GU/1310S/SM/LC
SFP/GBE/B1310S/SM/LC
SFP/GBE/B1310L/SM/LC
1490 nm types SFP/GBE/B1490L/SM/LC
SFP/GBE/B1490S/SM/LC

338 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

The following table provides information about the network port for all variants.
Table 623: Network Port - General Information for all Variants
Number of network ports 1
Type of network port Tunable DWDM interface
Optical connector type LC
Fiber type SM 9 µm
Data rates (multiplexer and framed mode) 9.95328 Gbit/s
Protocols STM-64, OC-192
Tuning time (any channel to any ch.) < 45 s
Tuning time cold start (any channel to any < 60 s
channel)
Max. shuttered output power (dark tuning) -30 dBm

The following table provides information about the network port for the
5TCE-PCTN-8GU+10GS-LN#DC.

Table 624: Network Port - Optical Performance for


5TCE-PCTN-8GU+10GS-LN#DC
Transmitter output power range -3 dBm ... 0 dBm
Transmitter wavelength range 81 channels, 50 GHz spacing in C
band acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 60 pm
Min. extinction ratio 11 dB
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Min. sidemode suppression ratio 40 dB


Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -14 dBm ... -1 dBm
OPR measurement range -18 dBm ... +2 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range -300 ps/nm ... +300 ps/nm
Dispersion load range with 1 dB -500 ps/nm ... -300 ps/nm and 
OSNR penalty +300 ps/nm ... +500 ps/nm
Dispersion load range with 2 dB -700 ps/nm ... -500 ps/nm and 
OSNR penalty +500 ps/nm ... +700 ps/nm
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)
OSNR penalty at -16 dBm Rx input 1 dB
power

This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-8GU+10GS-LN#DC.

Table 625: Bit Error Rate Versus OSNR for


5TCE-PCTN-8GU+10GS-LN#DC
Bit Error Ratio < 10-12 at 23 dB OSNR at 0.1 nm

Module and System Specification 339


5TCE-PCTN-8GU+10GS

The following table provides information about the network port for the
5TCE-PCTN-8GU+10GS-V#DC.

Table 626: Network Port - Optical Performance for


5TCE-PCTN-8GU+10GS-V#DC
Transmitter output power range +4 dBm ... +6 dBm
Transmitter wavelength range 81 channels, 50 GHz spacing in C band
acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 60 pm
Min. extinction ratio 10 dB
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -20 dBm ... -8 dBm
OSNR penalty at -22 dBm Rx input 1 dB
power
OPR measurement range -22 dBm ... -5 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range +200 ps/nm ... +800 ps/nm
Dispersion load range with 1dB -100 ps/nm ... +200 ps/nm and 
OSNR penalty +800 ps/nm ... +1100 ps/nm
Dispersion load range with 2dB -400 ps/nm ... -100 ps/nm and 
OSNR penalty +1100 ps/nm ... +1400 ps/nm
OSNR PMD penalty 1 dB at 10 ps

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
(outage probability 4x10-5)

This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-8GU+10GS-V#DC.

Table 627: Bit Error Rate Versus OSNR for 5TCE-PCTN-8GU+10GS-V#DC


Bit Error Ratio < 10-12 at 25 dB OSNR at 0.1 nm

The following table provides information about the operation modes for all
variants.

340 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 628: Operation Modes for all Variants


Transparent multiplexer Support of 11 virtual containers (VC).
mode Number of concatenated VCs needed:
1GbE = 2 VC
(starting at VC number 1 through 10 only)

1G FC = 2 VC
(starting at VC number 1 through 10 only)

2G FC = 3 VC
(starting at VC number 1 through 9 only)

4G FC = 5 VC
(starting at VC number 1 through 7 only)
Framed mode Support of 11 virtual containers (VC).
Number of concatenated VCs needed:
1G FC = 1 VC
(starting at every VC number possible)

2G FC or 1GbE = 2 VC
(starting at VC number 1, 3, 5, 7, 9 only)

4G FC = 4 VC
(starting at VC number 1, 5 only)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

8G FC = 8 VC
(starting at VC number 1, 4 only)
Mapping / Framing Mapping into proprietary used 
STM-64 framing acc. to ITU-T G.707 and
OC-192 according GR-253
Max. frame size for 
FC services 2148 bytes
GbE services 9600 bytes

The virtual containers required for an individual service have to be


PS

concatenated. In addition there is a restriction of the starting virtual


container in framed mode as stated in the table above.
Note

This table contains information about the system performance for all variants.

Module and System Specification 341


5TCE-PCTN-8GU+10GS

Table 629: System Performance for all Variants


Max. module delay in 1G FC: 5.5 µs
transparent multiplexer 2G FC: 4 µs
mode 4G FC: 3 µs
GbE: 5 µs
Max. module delay in 1G FC: 8.5 µs
framed mode 2G FC: 5 µs
4G FC: 3.5 µs
8G FC: 3 µs
GbE: 6 µs
Number of back-to-back 3 using 5TCE-PCTN-8GU+10GS
cascades (without
protection capability)
Number of regenerators 2 using 2WCA-PCN-10G as bidirectional single
module C-N regenerator using
XFP/11G/Dxxxx.xxV/SM/LC#Dxx and
XFP/11G/DCTV/SM/LC at a max. ambient
temperature of 45°C
7 using 2WCC-PCN-10G as bidirectional single
module C-N regenerator without FEC

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Note

This table shows information about fault monitoring of the module in general for
all variants.

Table 630: Fault Monitoring - General for all Variants


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Client port SFP missing;
Client port SFP mismatch

342 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

This table shows information about fault monitoring of the client ports in general
for all variants.

Table 631: Fault Monitoring Client Interface - General for all Variants
Physical layer Laser failure;
Laser degrade (based on bias current)
Loss of signal (LOS);
Auto shutdown (laser off condition);
Physical coding sublayer Loss of character synchronization1;
Auto shutdown - transmitting error
propagation code condition
1. Only supported in framed mode.

This table provides information about fault monitoring of the network ports in
general for all variants.

Table 632: Fault Monitoring Network Interface - General for all Variants
Physical layer Laser failure; Receiver clock synch failure;
Loss of signal (LOS)
SDH/SONET layer LOF; AIS; RDI; SD; LOP; UNEQ; PLM; RDI
Proprietary aggregate VF layer SSF; AIS; LKDO-AIS, SGEO-LASER

The following table provides information about performance monitoring of the


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

module in general for all variants.

Table 633: Performance Monitoring - General for all Variants


Equipment Module temperature (current value)
(with fix threshold crossing alert for
module temperature too high)

This table shows information about performance monitoring of the client ports
for all variants.

Table 634: Performance Monitoring Client Interface - General for all Variants
Physical layer (15 min/24 h records available for Transmitter bias current
PM values except current values; user (current); Optical power
configurable threshold crossing alerts for OPR too Rx (current, low, mean,
high/too low available; fix threshold crossing high); Optical power Tx
alerts for OPT too high/too low available) (current, low, mean, high)
Physical coding sublayer CV; DE; ES1
(15 min/24 h records with user configurable
threshold crossing alerts available)
1. CV, DE and ES - only supported in framed mode

Module and System Specification 343


5TCE-PCTN-8GU+10GS

This table shows information about performance monitoring of the network ports
for all variants.

Table 635: Performance Monitoring Network Interface - General for all


Variants
Physical layer Optical power Rx
(15 min/24 h records available for PM values (current, low, mean,
except current values; user configurable threshold high),
crossing alerts for OPR too high/too low available) Optical power Tx
fix threshold crossing alerts for OPT too high/too (current, low, mean, high)
low available)
STM-64/OC-192 layer ES; SES; UAS;
(15 min/24 h records with user configurable OOFS/SEFS; BBE/CV
threshold crossing alerts available)

This table provides information about the loop functionality for all variants.

Table 636: Loop Functionality for all Variants


Client ports Facility loop on individual port,
Terminal loop on individual port
Network port Facility loop, Terminal loop

This table shows information about protection setting for all variants.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 637: Protection Switching for all Variants
Protection scheme Versatile switched protection
(RSM-SF, RSM-OLM, VSM)
Protection switching time < 50 ms

This table contains information about the Embedded Controlled Channels


(ECCs) for all variants.
Table 638: Embedded Control Channel for all Variants
Notice: One DCC channel is supported per port
Client ports none
Network port SDCC (192 kbit/s); LDCC (576 kbit/s)

344 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

5TCE-PCTN-8GU+AES10GS
The 5TCE-PCTN-8GU+AES10GS module is a 5-port TDM channel module with
five pluggable client interfaces and one DWDM network interface supporting
data encryption. The module is designed according to FIPS Publication 140-2
with security level 2, and can be used for the transport of security-related data.
The aggregated data stream is encrypted/decrypted using the Advanced
Encryption Standard (AES). Data encryption and the use of an endpoint
authentication mechanism protect the network link between two communicating
5TCE-PCTN-8GU+AES10GS modules against man-in-the-middle attacks.
The module can operate in following TDM modes:
• Transparent multiplexer mode: 
The incoming data stream is physically terminated and mapped bit for bit
into VC4-64c or STS192c payload, and then mapped into STM64 or OC192
framing structure with reduced functionality according to ITU-T G.707 or
Telcordia GR-253. The client ports support 1G FC, 2G FC, 4G FC and
1GbE. The data rate on the network port depends on the application.
• Framed mode: 
In framed mode the physical coding sublayer (PCS) is terminated. The
8B/10B coding is removed prior to multiplexing. Rate adaption is performed
through byte stuffing. The client ports support 1G FC, 2G FC, 4G FC, 8G FC
and 1GbE. 8G FC can be applied at client port 1 only.
The 5TCE-PCTN-8GU+AES10GS is available in two variants:
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

• 5TCE-PCTN-8GU+AES10GS-LN#DC
• 5TCE-PCTN-8GU+AES10GS-V#DC
The 5TCE-PCTN-8GU+AES10GS-V#DC has very long reach network
interfaces.
The 5TCE-PCTN-8GU+AES10GS-LN#DC features a long reach noise
optimized network interface, which has a high extinction ratio suitable for links
with a large amount of amplifiers and low OSNR.
Table 639 contains general information about the module and its environment.

Table 639: Module - General Information for all Variants


Equipment type 5TCES10GTAES-D
First release 11.1
MTBF at 25°C ambient 210,109 h
temperature
Typ. power consumption 32 W
Max. power consumption 42 W
Width 4 HP
Height 5 HU
Weight 725 g (1.6 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS), ETSI EN
for SH9HU 300 019-1-3 Class 3.1

Module and System Specification 345


5TCE-PCTN-8GU+AES10GS

Table 639: Module - General Information for all Variants (Continued)


Environmental conditions Operating temperature: +5°C … +40°C
for SH7HU, SH7HU-R, 5% ... 85% relative humidity (non-condensing)
SH1HU-R, SH1HU-F/2DC,
SH1HU-HP/2DC Short-term temperature: -5°C … +45°C
SH1HU-HP/E-TEMP/2DC 5% ... 90% relative humidity (non-condensing)
Environmental conditions Operating temperature: +5°C … +40°C
for SH1HU-R/PF 5% ... 85% relative humidity (non-condensing)

Short-term temperature: -5°C … +55°C


5% ... 90% relative humidity (non-condensing)
Degree of protection IP20. Use in a pollution degree 2 environment
according to IEC 60529 and indoor controlled office environments only.
Slot positions SH9HU: slots 3...18
SH7HU, SH7HU-R: slots 3...18
SH1HU: slots 1, 2
NCU types NCU-II, NCU-II-P

The following table provides information about the client ports for all variants.

Table 640: Client Ports - Specifications for all Variants


Number of client ports 5
Optical connector type LC

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Type of client ports SFP (client ports 1 to 5)
SFP+ (client port 1 only)
Data rates (transparent multiplexer 1.250 Gbit/s, 1.0625 Gbit/s, 
mode) 2.125 Gbit/s, 4.250 Gbit/s
Data rates (framed mode) 1.250 Gbit/s, 1.0625 Gbit/s, 
2.125 Gbit/s, 4.250 Gbit/s
Data rates (framed mode), client 8.5 Gbit/s
port C1 only
Protocols (transparent multiplexer GbE, 1G FC, 2G FC (incl. 2G Coupling
mode) Link), 4G FC
Protocols (framed mode) GbE, 1G FC, 2G FC, 4G FC, 8G FC

This table provides a summary of the supported client SFPs. Please refer to the
specifications for the individual SFP type.
Table 641: Supported Client SFPs for all Variants
850 nm types SFP/2G1/850I/MM/LC
SFP/4GU/850I/MM/LC
SFP+/8GU/850I/MM/LC (client port 1)
SFP+/11GU/850I/MM/LC (client port 1)
1310 nm types SFP/HS/1310S/SM/LC
SFP/CL/1310I/SM/LC
SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
SFP/4GU/1310S/SM/LC
SFP+/8GU/1310S/SM/LC (client port 1)
SFP+/11GU/1310S/SM/LC (client port 1)

346 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

The following table provides information about the network port for all variants.
Table 642: Network Port - General Information for all Variants
Number of network ports 1
Type of network port Tunable DWDM interface
Optical connector type LC
Fiber type SM 9 µm
Data rates (multiplexer and framed mode) 9.95328 Gbit/s
Protocols STM-64, OC-192
Tuning time (any channel to any ch.) < 45 s
Tuning time cold start (any channel to any channel) < 60 s
Max. shuttered output power (dark tuning) -30 dBm

Table below provides information about encryption on the network port for all
variants.

Table 643: Network Port - Encryption for all Variants


Encryption of payload acc. Advanced Encryption Standard
with 256 bit key in counter mode
Module design acc. NIST FIPS 140-2 “Security
Requirements for Cryptography
Modules” - security level 2
Key exchange (hardware true every 10 minutes
random number generator)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Typ. initial key exchange before < 3 min


data transmission
Far-end authentication PACE protocol
Key exchange with Diffie-Hellman Diffie-Hellman group #5 from RFC3526
with 1536 bit key length

The following table provides information about the network port for the
5TCE-PCTN-8GU+AES10GS-LN#DC.

Table 644: Network Port - Optical Performance for


5TCE-PCTN-8GU+AES10GS-LN#DC
Transmitter output power range -3 dBm ... 0 dBm
Transmitter wavelength range 81 channels, 50 GHz spacing in C
band acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 60 pm
Min. extinction ratio 11 dB
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -14 dBm ... -1 dBm
OPR measurement range -18 dBm ... +2 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range -300 ps/nm ... +300 ps/nm
Dispersion load range with 1 dB OSNR -500 ps/nm ... -300 ps/nm and 
penalty +300 ps/nm ... +500 ps/nm
Dispersion load range with 2 dB OSNR -700 ps/nm ... -500 ps/nm and 
penalty +500 ps/nm ... +700 ps/nm

Module and System Specification 347


5TCE-PCTN-8GU+AES10GS

Table 644: Network Port - Optical Performance for


5TCE-PCTN-8GU+AES10GS-LN#DC (Continued)
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)
OSNR penalty at -16 dBm Rx input power 1 dB

This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-8GU+10GS-LN#DC.

Table 645: Bit Error Rate Versus OSNR for


5TCE-PCTN-8GU+AES10GS-LN#DC
Bit Error Ratio < 10-12 at 23 dB OSNR at 0.1 nm

The following table provides information about the network port for the
5TCE-PCTN-8GU+10GS-V#DC.

Table 646: Network Port - Optical Performance for


5TCE-PCTN-8GU+AES10GS-V#DC
Transmitter output power range +4 dBm ... +6 dBm
Transmitter wavelength range 81 channels, 50 GHz spacing in 
C band acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 60 pm
Min. extinction ratio 10 dB

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -20 dBm ... -8 dBm
OSNR penalty at -22 dBm Rx input 1 dB
power
OPR measurement range -22 dBm ... -5 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range +200 ps/nm ... +800 ps/nm
Dispersion load range with 1dB OSNR -100 ps/nm ... +200 ps/nm and 
penalty +800 ps/nm ... +1100 ps/nm
Dispersion load range with 2dB OSNR -400 ps/nm ... -100 ps/nm and 
penalty +1100 ps/nm ... +1400 ps/nm
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)

This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-8GU+10GS-V#DC.

Table 647: Bit Error Rate Versus OSNR for


5TCE-PCTN-8GU+AES10GS-V#DC
Bit Error Ratio < 10-12 at 25 dB OSNR at 0.1 nm

348 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table below provides information about the operation modes for all variants.

Table 648: Operation Modes for all Variants


Transparent multiplexer Support of 11 virtual containers (VC).
mode Number of consecutive VCs needed:
1GbE = 2 VC
(starting at VC number 1 through 10 only)

1G FC = 2 VC
(starting at VC number 1 through 10 only)

2G FC = 3 VC
(starting at VC number 1 through 9 only)

4G FC = 5 VC
(starting at VC number 1 through 7 only)
Framed mode Support of 11 virtual containers (VC).
Number of consecutive VCs needed:
1G FC = 1 VC
(starting at every VC number possible)

2G FC or 1GbE = 2 VC
(starting at VC number 1, 3, 5, 7, 9 only)

4G FC = 4 VC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

(starting at VC number 1, 5 only)

8G FC = 8 VC
(starting at VC number 1, 4 only)
Mapping / Framing Mapping into proprietary used STM-64
framing acc. to ITU-T G.707 and OC-192
according GR-253
Max. frame size for 
FC services 2148 bytes
GbE services 9600 bytes

The virtual containers required for an individual service have to be


PS

concatenated. In addition there is a restriction of the starting virtual


container in framed mode as stated in the table above.
Note

Module and System Specification 349


5TCE-PCTN-8GU+AES10GS

This table contains information about the system performance for all variants.

Table 649: System Performance for all Variants


Max. module delay in 1G FC: 5.5 µs
transparent multiplexer mode 2G FC: 4 µs
4G FC: 3 µs
GbE: 5 µs
Max. module delay in framed 1G FC: 8.5 µs
mode 2G FC: 5 µs
4G FC: 3.5 µs
8G FC: 3 µs
GbE: 6 µs
Number of back-to-back 3 using 5TCE-PCTN-8GU+AES10GS
cascades (without protection
capability)
Number of regenerators 2 using 2WCA-PCN-10G as bidirectional
single module C-N regenerator using
XFP/11G/Dxxxx.xxV/SM/LC#Dxx and
XFP/11G/DCTV/SM/LC at a max. ambient
temperature of 45°C
7 using 2WCC-PCN-10G as bidirectional
single module C-N regenerator without
FEC

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Whether fault/performance monitoring entries listed in the
PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

This table shows information about fault monitoring of the module in general for
all variants.

Table 650: Fault Monitoring - General for all Variants


Equipment Module removed; Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Client port SFP missing;
Client port SFP mismatch

350 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

This table shows information about fault monitoring of the client ports in general
for all variants.

Table 651: Fault Monitoring Client Interface - General for all Variants
Physical layer Laser failure;
Laser degrade (based on bias current)
Loss of signal (LOS);
Auto shutdown (laser off condition);
Physical coding sublayer Loss of character synchronization1;
Auto shutdown - transmitting error
propagation code condition
1. Only supported in framed mode.

This table provides information about fault monitoring of the network ports in
general for all variants.

Table 652: Fault Monitoring Network Interface - General for all Variants
Physical layer Laser failure; Receiver clock synch failure;
Loss of signal (LOS)
SDH/SONET layer LOF; AIS; RDI; SD; LOP; UNEQ; PLM; RDI
Proprietary VF layer SSF; AIS; LKDO-AIS, SGEO-LASER

The following table provides information about performance monitoring of the


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

module in general for all variants.

Table 653: Performance Monitoring - General for all Variants


Equipment Module temperature (current value)
(with fix threshold crossing alert for
module temperature too high)

This table shows information about performance monitoring of the client ports
for all variants.

Table 654: Performance Monitoring Client Interface - General for all Variants
Physical layer Transmitter bias current
(15 min/24 h records available for PM values (current); Optical power
except current values; user configurable threshold Rx (current, low, mean,
crossing alerts for OPR too high/too low available; high); Optical power Tx
fix threshold crossing alerts for OPT too high/too (current, low, mean, high)
low available)
Physical coding sublayer CV; DE; ES1
(15 min/24 h records with user configurable
threshold crossing alerts available)
1. CV, DE and ES - only supported in framed mode

Module and System Specification 351


5TCE-PCTN-8GU+AES10GS

This table shows information about performance monitoring of the network ports
for all variants.

Table 655: Performance Monitoring Network Interface - General for all


Variants
Physical layer Optical power Rx
(15 min/24 h records available for PM values (current, low, mean,
except current values; user configurable threshold high),
crossing alerts for OPR too high/too low available) Optical power Tx
fix threshold crossing alerts for OPT too high/too (current, low, mean, high)
low available)
STM-64/OC-192 layer ES; SES; UAS;
(15 min/24 h records with user configurable OOFS/SEFS; BBE/CV
threshold crossing alerts available)

Table below gives information about performance monitoring for encryption.

Table 656: Performance Monitoring - Encryption for all Variants


15 min/24 h records encryption running
encryption running in “degraded mode”
encryption not running
time stamp last successful key exchange
last failed key exchange
last change of Crypto-Officer password

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
last failed Crypto-Officer password
timer (countdown) remaining session- key lifetime
remaining time running in bypass mode

This table provides information about the loop functionality for all variants.

Table 657: Loop Functionality for all Variants


Client ports Facility loop on individual port,
Terminal loop on individual port
Network port Facility loop, Terminal loop
(Facility and terminal loop on the
network port is only allowed for bypass
applications when encryption is
disabled.)

This table shows information about restoration setting for all variants.

Table 658: Restoration Scheme for all Variants


Restoration scheme Versatile switched protection
(RSM-SF, RSM-OLM, VSM)
Restoration time <500 ms

352 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

This table contains information about the Embedded Controlled Channels


(ECCs) for all variants.
Table 659: Embedded Control Channels for all Variants
Notice: One DCC channel is supported per port
Client ports none
Network port SDCC (192 kbit/s); LDCC (576 kbit/s)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 353


5TCE-PCN-10GU+10G

5TCE-PCN-10GU+10G
The 5TCE-PCN-10GU+10G module is a 5-port 10G enterprise type TDM
channel module with five SFP/SFP+ interfaces on the client side and a single
SFP+ interface on the network side.
The module can operate in following modes:
• TDM mode
o
Transparent multiplexer mode: 
The incoming data stream is mapped bit for bit in a simplified G.709
frame. The client ports support 1G FC, 2G FC, F2488 (STM16/OC-48),
4G FC, 5G IB, and 1GbE. The data rate on the network port depends on
the application. Transport of 5G IB services is supported in the TDM
mode multiplexing up to 2 x 5G IB. 5G IB transport requires the use of
the appropriate SFP+ devices in the client interfaces C1 and C2.
o Framed mode: 
In framed mode the physical coding sublayer (PCS) is terminated. The
8B/10B coding is removed prior to multiplexing. Rate adaption is
performed through byte stuffing. The client ports support 1G FC, 2G FC,
4G FC, 8G FC and 1GbE. 8G FC can be applied at client port 1 only.
• Transparent transponder mode:
This mode is similar to the transparent multiplexer mode, but it allows to
transport 8G FC, F9953 (STM64/OC-192), 10G FC, and 10GbE LAN as
single service only applied at client port 1.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 660 provides general information about the module and its environment.

Table 660: Module - General Information


Equipment type 5TCE10G
First release 12.3
MTBF at 25°C ambient 407,352 h
temperature
Typ. power consumption (incl. 26 W in TDM mode
pluggable transceivers) 22 W in transponder mode
Max. power consumption 38 W
Width 4 HP
Height 5 HU
Weight 725 g (1.6 lbs)
Environmental conditions for Telcordia SR-3580 level 3 (NEBS), ETSI
SH9HU EN 300 019-1-3 Class 3.1
Environmental conditions for Operating temperature: +5°C … +40°C
SH7HU, SH7HU-R, SH1HU-R, 5% ... 85% relative humidity
SH1HU-F/2DC, (non-condensing)
SH1HU-HP/2DC
Short-term temperature: -5°C … +45°C
5% ... 90% relative humidity
(non-condensing)

354 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 660: Module - General Information (Continued)


Environmental conditions for Operating temperature: +5°C … +40°C
SH1HU-R/PF 5% ... 85% relative humidity
(non-condensing)

Short-term temperature: -5°C … +55°C


5% ... 90% relative humidity
(non-condensing)
Degree of protection according IP20. Use in a pollution degree 2
to IEC 60529 environment and indoor controlled office
environments only.
Slot positions SH9HU: slots 3...18
SH7HU, SH7HU-R: slots 3...18
SH1HU-F/2DC, SH1HU-HP/2DC,
SH1HU-HP/E-TEMP/2DC: slots 1, 2
NCU types NCU-II, NCU-II-P

Table 661 provides information about the client ports.

Table 661: Client Ports - Specifications


Number of client ports 5
Optical connector type LC
Type of client ports SFP (client port 1 to 5)
SFP+ (client ports 1 and 2 only)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Data rates (transparent 8.5 Gbit/s, 9.95328 Gbit/s, 10.51875 Gbit/s,


transponder mode), client port 10.3125 Gbit/s
C1 only
Data rates (transparent 1.25 Gbit/s, 1.0625 Gbit/s, 2.125 Gbit/s,
multiplexer mode) 2.48832 Gbit/s, 4.250 Gbit/s
Data rates (transparent 5.0 Gbit/s
multiplexer mode), client port C1
and C2 only
Data rates (framed mode) 1.25 Gbit/s, 1.0625 Gbit/s, 2.125 Gbit/s,
4.250 Gbit/s
Data rates (framed mode), client 8.5 Gbit/s
port C1 only
Protocols (transparent 8G FC, F9953, 10G FC, 10 GbE LAN PHY,
transponder mode) ITU-T G.8262 and IEEE 1588v2 compliant
transparent Ethernet transport
Protocols (transparent GbE, 1G FC, 2G FC (incl. 2G Coupling
multiplexer mode) Link), F2488, 4G FC, 5G IB, ITU-T G.8262
and IEEE 1588v2 compliant transparent
Ethernet transport
Protocols (framed mode) GbE, 1G FC, 2G FC, 4G FC, 8G FC

Module and System Specification 355


5TCE-PCN-10GU+10G

Table 662 provides a summary of the supported client SFP/SFP+ transceivers.


Please refer to the specifications for the individual SFP/SFP+ type.

Table 662: Supported Client SFP/SFP+ Transceivers


850 nm types SFP/2G1/850I/MM/LC
SFP/4GU/850I/MM/LC
SFP+/11GU/850I/MM/LC1 (client ports 1 and 2)
1310 nm types SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
SFP/4GU/1310S/SM/LC
SFP+/11GU/1310S/SM/LC1 (client ports 1 and 2)
1. 10G data rates supported on client port C1 only.

Table 663 provides information about the network port.

Table 663: Network Port - Specifications


Number of network ports 1
Type of network ports SFP+
Data rates 10.9747 Gbit/s for 8G FC,
(transparent transponder mode) 11.3176 Gbit/s for 10G FC
11.0957Gbit/s for 10 GbE,
10.7092Gbit/s for F9953
Data rates 11.3176 Gbit/s

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
(multiplexer mode, transparent as well as
framed)
Protocols Subset G. 709 OTU2

Table 664 provides a summary of the supported network SFP+ transceivers.


Please refer to the specifications for the individual SFP+ type.

Table 664: Supported Network SFP+ Transceivers


CWDM types SFP+/11GU/CxxxxL/SM/LC
DWDM types SFP+/11GU/#19xxxL50/SM/LC

356 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 665 provides information about the operation modes.

Table 665: Operation Modes


Transparent transponder mode 8G FC, F9953, 10G FC, and 10GbE LAN
as single service only
Transparent multiplexer mode Support of 12 virtual containers (VC).
Number of concatenated VCs needed:
1GbE = 2 VC 
(starting at VC number 1 through 11 only)

1G FC = 2 VC
(starting at VC number 1 through 11 only)

2G FC, F2488 = 3 VC
(starting at VC number 1 through 10 only)

4G FC = 5 VC
(starting at VC number 1 through 8 only)

5G IB = 6VC
(starting at VC number 1, 7 only)
Framed mode Support of 12 virtual containers (VC).
Number of concatenated VCs needed:
1G FC = 1 VC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

(starting at every VC number possible)


2G FC or 1GbE = 2 VC
(starting at VC number 1, 3, 5, 7, 9, 11 only)
4G FC = 4 VC
(starting at VC number 1, 5, 9 only)
8G FC = 8 VC
(starting at VC number 1, 5 only)
Max. frame size for:  
FC services < 2200 bytes
GbE services 9600 bytes

The virtual containers required for an individual service have to be


PS

concatenated. In addition there is a restriction of the starting virtual


container in framed mode as stated in the table above.
Note

Module and System Specification 357


5TCE-PCN-10GU+10G

Table 666 provides information about the system performance.

Table 666: System Performance


Max. module delay in 1G FC: 5 µs without FEC / 10 µs with FEC
transparent multiplexer 2G FC: 3.5 µs without FEC / 8.5 µs with FEC
mode and transparent F2488: 3.5 µs without FEC / 8.5 µs with FEC
transponder mode 4G FC: 2.5 µs without FEC / 7.5 µs with FEC
8G FC: 1.5 µs without FEC / 7 µs with FEC
10G FC: 1.5 µs without FEC / 7 µs with FEC
1 GbE: 5 µs without FEC / 10 µs with FEC
F9953: 1.5 µs without FEC / 7 µs with FEC
10 GbE LAN PHY: 1.5 µs without FEC / 7 µs with
FEC
5G IB: 2.5 µs without FEC / 8 µs with FEC
Max. module delay in 1G FC: 7.5 µs without FEC / 13 µs with FEC
framed mode 2G FC: 4.5 µs without FEC / 10 µs with FEC
4G FC: 3 µs without FEC / 8 µs with FEC
8G FC: 2.3 µs without FEC / 7.5 µs with FEC
1GbE: 6 µs without FEC / 11 µs with FEC
Number of back-to-back 3 using 5TCE-PCN-10GU+10G
cascades (without
protection capability)
Number of regenerators 2 using 2WCC-PCN-10G as bidirectional single
module C-N regenerator supporting data rates of

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
10.709 Gbit/s and 11.0957 Gbit/s;
For these data rates the module can interwork
with the 10TCC-PCTN-100G as OTU2
aggregator.

Table 667 provides information about the multiplexing and mapping schemes.

Table 667: Multiplexing and Mapping Schemes


TDM (muxponder) Multiplexed aggregated client signal mapped into
mode proprietary used OPU2/ ODU2 framing structure acc.
to ITU-T G.7091
Transponder mode Client service mapped into proprietorial used OPU2/
ODU2 framing structure acc. to ITU-T G.7091
1. No full standard compliant implementation in all aspects of ITU-T G.709

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

358 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 668 provides information about fault monitoring on the module equipment
level in general.

Table 668: Fault Monitoring Equipment - General


Equipment Alarm Name TL-1 Keyword
Module Equipment removed RMVD
Equipment mismatch MEA-CONDITION
Equipment Fault HWFLT
Voltage Out of Range VOLTANR
FWP-Mismatch (NSA) FWPM-NSA
FWP-Mismatch (SA) FWPM-SA

Table 669 provides information about fault monitoring of the client interfaces.

Table 669: Fault Monitoring Client Interfaces


Layer Alarm Name TL-1 Keyword
Physical layer Laser-fail LASER
Laser degrade (based on bias current) LBCLANR
Loss of signal LOS
SFP/SFP+ Removed RMVD
SFP/SFP+ Physical Mismatch MEA-PHYS
SFP/SFP+ Not Approved MEA-APPROVE
SFP/SFP+ Voltage Out of Range VOLTANR
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Auto Shutdown-Forward LKDO-OFF


PCS layer Loss of character synchronization1 CHARSYNCH
Autonomous shutdown LKDO-EPC
1. Only supported in framed mode

Table 670 provides information about fault monitoring of the network interface.

Table 670: Fault Monitoring Network Interface


Layer Alarm Name TL-1 Keyword
Physical layer Laser-fail LASER
Laser degrade (based on bias current) LBCLANR
Rx Clock - Loss of Sync RCVCLK
Loss of signal LOS
SFP+ Removed RMVD
SFP+ Physical Mismatch MEA-PHYS
SFP+ Not Approved MEA-APPROVE
SFP+ Voltage Out of Range VOLTANR
OCH//OTU2 layer OTU-Loss of Frame OTU-LOF
ODU layer Alarm Indication Signal AIS-ODU
Open connection indication OCI-ODU
Lock LCK-ODU
OPU2 layer Auto Shutdown AIS LKDO-AIS-OPU
Generic AIS AIS-OPU

Module and System Specification 359


5TCE-PCN-10GU+10G

Table 670: Fault Monitoring Network Interface (Continued)


Proprietary Forward Client Fail LKDO-AIS-VF
aggregate VF FEND Client Fail-AIS AIS-VF
layer Server Signal Failure SSF-VF
Entity Outage SGEO-LASER

Table 671 provides information about performance monitoring on the module


equipment level in general.

Table 671: Performance Monitoring - General


Layer PM Name TL-1 Keyword
Equipment Module temperature - current analogue value T-TEMP-FHT
(Fix threshold crossing alert for module
temperature too high available)

Table 672 provides information about performance monitoring values supported


on the client interfaces in ingress direction.

Table 672: Client Interface Performance Monitoring


Layer PM Name TL-1 Keyword
Physical layer Optical input power Rx - T-OPR-HT
current, low, mean, high T-OPR-LT
(15 min/24 h records available
for PM values except current

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
value; user configurable
threshold crossing alerts for
OPR too high / OPR too low)
Optical output power Tx - T-OPT-FHT
current, low, mean, high T-OPT-FLT
(15 min/24 h records available
for PM values except current
value; fix threshold crossing
alerts for OPT too high / OPT
too low)
SFP/SFP+ T-TEMP-FHT
current analogue value T-TEMP-FLT
(Fix threshold crossing alert for
CFP transceiver temperature
too high/too low available)
Laser bias current level LBCL
(current analogue value)
Latency - measured round trip T-LATENCY-HT
client-to-client T-LATENCY-LT
- current, low, mean, high
(15 min/24 h records available
for PM values except current
value; user configurable
threshold crossing alerts for
latency too high / latency too
low)

360 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 672: Client Interface Performance Monitoring (Continued)


PCS layer - ingress Coding violations 1 CV
direction only (15 min/24 h records available;
user configurable threshold
crossing alerts for CV too high)
Disparity Errors 1 DE
(15 min/24 h records available;
user configurable threshold
crossing alerts for DE too high)
Errored seconds 1 ES
(15 min/24 h records available;
user configurable threshold
crossing alerts for ES too high)
1. CV, DE and ES are supported in framed mode only.

Table 673 provides information about performance monitoring values supported


on the network interface.

Table 673: Network Interface Performance Monitoring


Layer PM Name TL-1 Keyword
Physical layer Optical input power Rx - current, T-OPR-HT
low, mean, high T-OPR-LT
(15 min/24 h records available for
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

PM values except current value;


user configurable threshold
crossing alerts for OPR too high /
OPR too low)
Optical output power Tx - current, T-OPT-FHT
low, mean, high T-OPT-FLT
(15 min/24 h records available for
PM values except current value; fix
threshold crossing alerts for OPT
too high / OPT too low)
SFP/SFP+ T-TEMP-FHT
current analogue value T-TEMP-FLT
(Fix threshold crossing alert for
CFP transceiver temperature too
high/too low available)
Laser bias current level (current LBCL
analogue value)
Latency - measured round trip T-RNDTRPDLY-HT
network-to-network T-RNDTRPDLY-LT
- current, low, mean, high
(15 min/24 h records available for
PM values except current value;
user configurable threshold
crossing alerts for latency too high /
latency too low)

Module and System Specification 361


5TCE-PCN-10GU+10G

Table 673: Network Interface Performance Monitoring (Continued)


FEC layer Corrected errors CE-FEC
(15 min/24 h records; user
configurable threshold crossing
alerts for CE too high)
Uncorrectable block errors UBE-FEC
(15 min/24 h records; user
configurable threshold crossing
alerts for UBE too high)
Errored seconds ES-FEC
(15 min/24 h records; user
configurable threshold crossing
alerts for ES too high)
Severely errored seconds SES-FEC
(15 min/24 h records; user
configurable threshold crossing
alerts for SES too high)
pre-FEC BER BERCE-FEC
(15 min/24 h records; user
configurable threshold crossing
alerts for pre-FEC BER too high)
OTU2 layer Errored seconds ES-OTU
(15 min/24 h records; user
configurable threshold crossing

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
alerts for ES too high)
Severely errored seconds SES-OTU
(15 min/24 h records; user
configurable threshold crossing
alerts for SES too high)
Unavailable seconds UAS-OTU
(15 min/24 h records; user
configurable threshold crossing
alerts for UAS too high)
Background block errors BBE-OTU
(15 min/24 h records; user
configurable threshold crossing
alerts for BBE too high)

Table 674 provides information about the loop functionality.

Table 674: Loop Functionality


Client ports Facility loop on individual port,
Terminal loop on individual port
Network port Facility loop, Terminal loop

Table 675 provides information about protection setting for all variants.

Table 675: Protection Switching


Protection scheme Client channel card protection
Protection switching time < 50 ms

362 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 675: Protection Switching (Continued)


Protection switching criteria Physical signal fail (SF) switching
criteria:
LOS; SSF-VF; AIS-VF; AIS-OPU;
Client SFP removed; Network SFP+
removed
OTN signal fail (SF) switching criteria:
ODU-AIS; ODU-LCK; ODU-OCI
Restoration scheme Versatile switched protection
(RSM-SF, RSM-OLM, VSM)
Restoration time <50 ms

Table 676 provides information about the Embedded Controlled Channels


(ECCs).

Table 676: Embedded Control Channels


Notice: One GCC channel is supported per port
Client ports none
Network port GCC0 (1312 kbit/s)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 363


5TCE-PCN-10GU+AES10G

5TCE-PCN-10GU+AES10G
The 5TCE-PCN-10GU+AES10G module is a 5-port 10G enterprise type TDM
channel module with five SFP/SFP+ interfaces on the client side and a single
SFP+ interface on the network side supporting data encryption. The module is
designed according to FIPS Publication 140-2 with security level 2, and can be
used for the transport of security-related data. The aggregated data stream is
encrypted/decrypted using the Advanced Encryption Standard (AES). Data
encryption and the use of an endpoint authentication mechanism protect the
network link between two communicating 5TCE-PCN-10GU+AES10G modules
against man-in-the-middle attacks.
The module can operate in following modes:
• TDM mode
o Transparent multiplexer mode: 
The incoming data stream is mapped bit for bit in a simplified G.709
frame. The client ports support 1G FC, 2G FC, F2488 (STM16/OC-48),
4G FC, 5G IB, and 1GbE. The data rate on the network port depends on
the application. Transport of 5G IB services is supported in the TDM
mode multiplexing up to 2 x 5G IB. 5G IB transport requires the use of
the appropriate SFP+ devices in the client interfaces C1 and C2.
o Framed mode: 
In framed mode the physical coding sublayer (PCS) is terminated. The
8B/10B coding is removed prior to multiplexing. Rate adaption is

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
performed through byte stuffing. The client ports support 1G FC, 2G FC,
4G FC, 8G FC and 1GbE. 8G FC can be applied at client port 1 only.
• Transparent transponder mode:
This mode is similar to the transparent multiplexer mode, but it allows to
transport 8G FC, F9953 (STM64/OC-192), 10G FC, and 10GbE LAN as
single service only applied at client port 1.
Table 677 provides general information about the module and its environment.

Table 677: Module - General Information


Equipment type 5TCE10GAES
First release 12.3
MTBF at 25°C ambient 408,248 h
temperature
Typ. power consumption (incl. 29 W in TDM mode
pluggable transceivers) 25 W in transponder mode
Max. power consumption (incl. 42 W
pluggable transceivers)
Width 4 HP
Height 5 HU
Weight 725 g (1.6 lbs)
Environmental conditions for Telcordia SR-3580 level 3 (NEBS), ETSI
SH9HU EN 300 019-1-3 Class 3.1

364 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 677: Module - General Information (Continued)


Environmental conditions for Operating temperature: +5°C … +40°C
SH7HU, SH7HU-R, SH1HU-R, 5% ... 85% relative humidity
SH1HU-F/2DC, (non-condensing)
SH1HU-HP/2DC,
SH1HU-HP/E-TEMP/2DC Short-term temperature: -5°C … +45°C
5% ... 90% relative humidity
(non-condensing)
Environmental conditions for Operating temperature: +5°C … +40°C
SH1HU-R/PF 5% ... 85% relative humidity
(non-condensing)

Short-term temperature: -5°C … +55°C


5% ... 90% relative humidity
(non-condensing)
Degree of protection according IP20. Use in a pollution degree 2
to IEC 60529 environment and indoor controlled office
environments only.
Slot positions SH9HU: slots 3...18
SH7HU, SH7HU-R: slots 3...18
SH1HU-F/2DC, SH1HU-HP/2DC,
SH1HU-HP/E-TEMP/2DC: slots 1, 2
NCU types NCU-II, NCU-II-P
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 678 provides information about the client ports.

Table 678: Client Ports - Specifications


Number of client ports 5
Optical connector type LC
Type of client ports SFP (client port 1 to 5)
SFP+ (client ports 1 and 2 only)
Data rates (transparent 8.5 Gbit/s, 9.95328 Gbit/s,10.51875 Gbit/s,
transponder mode), client port 10.3125 Gbit/s
C1 only
Data rates (transparent 1.25 Gbit/s, 1.0625 Gbit/s, 2.125 Gbit/s,
multiplexer mode) 2.48832 Gbit/s, 4.250 Gbit/s
Data rates (transparent 5.0 Gbit/s
multiplexer mode), client port C1
and C2 only
Data rates (framed mode) 1.25 Gbit/s, 1.0625 Gbit/s, 2.125 Gbit/s,
4.250 Gbit/s
Data rates (framed mode), client 8.5 Gbit/s
port C1 only
Protocols (transparent 8G FC, F9953, 10G FC, 10 GbE LAN PHY,
transponder mode) ITU-T G.8262 and IEEE 1588v2 compliant
transparent Ethernet transport

Module and System Specification 365


5TCE-PCN-10GU+AES10G

Table 678: Client Ports - Specifications (Continued)


Protocols (transparent GbE, 1G FC, 2G FC, F2488, 4G FC, 5G IB,
multiplexer mode) ITU-T G.8262 and IEEE 1588v2 compliant
transparent Ethernet transport
Protocols (framed mode) GbE, 1G FC, 2G FC, 4G FC, 8G FC

Table 679 provides a summary of the supported client SFP/SFP+ transceivers.


Please refer to the specifications for the individual SFP/SFP+ type.

Table 679: Supported Client SFP/SFP+ Transceivers


850 nm types SFP/2G1/850I/MM/LC
SFP/4GU/850I/MM/LC
SFP+/11GU/850I/MM/LC1 (client ports 1 and 2)
1310 nm types SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
SFP/4GU/1310S/SM/LC
SFP+/11GU/1310S/SM/LC1 (client ports 1 and 2)
1. 10G data rates supported on client port C1 only.

Table 680 provides information about the network port.

Table 680: Network Port - Specifications


Number of network ports 1

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Type of network ports SFP+
Data rates 10.9747 Gbit/s for 8G FC,
(transparent transponder mode) 11.3176 Gbit/s for 10G FC
11.0957Gbit/s for 10 GbE,
10.709Gbit/s for F9953
Data rates 11.3176 Gbit/s
(multiplexer mode, transparent as well as
framed)
Protocols Subset G. 709 OTU2

Table 681 provides a summary of the supported network SFP+ transceivers.


Please refer to the specifications for the individual SFP+ type.

Table 681: Supported Network SFP+ Transceivers


CWDM types SFP+/11GU/CxxxxL/SM/LC
DWDM types SFP+/11GU/#19xxxL50/SM/LC

Table 682 provides information about encryption on the network port.

Table 682: Network Port - Encryption


Encryption of payload acc. Advanced Encryption Standard
with 256 bit key in counter mode
Module design acc. NIST FIPS 140-2 “Security
Requirements for Cryptographic
Modules” - security level 2

366 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 682: Network Port - Encryption (Continued)


Key exchange (hardware true every 10 minutes
random number generator)
Typ. initial key exchange before < 3 min
data transmission
Far-end authentication PACE protocol
Key exchange with Diffie-Hellman Diffie-Hellman group #5 from RFC3526
with 1536 bit key length

Table 683 provides information about the operation modes.

Table 683: Operation Modes


Transparent transponder mode 8G FC, F9953, 10G FC, 10GbE LAN as
single service only
Transparent multiplexer mode Support of 12 virtual containers (VC).
Number of concatenated VCs needed:
1GbE = 2 VC 
(starting at VC number 1 through 11 only)

1G FC = 2 VC
(starting at VC number 1 through 11 only)

2G FC, F2488 = 3 VC
(starting at VC number 1 through 10 only)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

4G FC = 5 VC
(starting at VC number 1 through 8 only)

5G IB = 6VC
(starting at VC number 1, 7 only)
Framed mode Support of 12 virtual containers (VC).
Number of concatenated VCs needed:
1G FC = 1 VC
(starting at every VC number possible)
2G FC or 1GbE = 2 VC
(starting at VC number 1, 3, 5, 7, 9, 11 only)
4G FC = 4 VC
(starting at VC number 1, 5, 9 only)
8G FC = 8 VC
(starting at VC number 1, 5 only)
Max. frame size for:  
FC services < 2200 bytes
GbE services 9600 bytes

The virtual containers required for an individual service have to be


PS

concatenated. In addition there is a restriction of the starting virtual


container in framed mode as stated in the table above.
Note

Module and System Specification 367


5TCE-PCN-10GU+AES10G

Table 684 provides information about the system performance.

Table 684: System Performance


Max. module delay in 1G FC: 5 µs without FEC / 10 µs with FEC
transparent multiplexer 2G FC: 3.5 µs without FEC / 8.5 µs with FEC
mode and transparent F2488: 3.5 µs without FEC / 8.5 µs with FEC
transponder mode 4G FC: 2.5 µs without FEC / 7.5 µs with FEC
8G FC: 1.5 µs without FEC / 7 µs with FEC
10G FC: 1.5 µs without FEC / 7 µs with FEC
1 GbE: 5 µs without FEC / 10 µs with FEC
F9953: 1.5 µs without FEC / 7 µs with FEC
10 GbE LAN PHY: 1.5 µs without FEC / 7 µs with
FEC
5G IB: 2.5 µs without FEC / 8 µs with FEC
Max. module delay in 1G FC: 7.5 µs without FEC / 13 µs with FEC
framed mode 2G FC: 4.5 µs without FEC / 10 µs with FEC
4G FC: 3 µs without FEC / 8 µs with FEC
8G FC: 2.3 µs without FEC / 7.5 µs with FEC
1GbE: 6 µs without FEC / 11 µs with FEC
Number of back-to-back 3 using 5TCE-PCN-10GU+AES10G
cascades (without
protection capability)
Number of regenerators 2 using 2WCC-PCN-10G as bidirectional single
module C-N regenerator supporting data rates of

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
10.709 Gbit/s and 11.0957 Gbit/s;
For these data rates the module can interwork
with the 10TCC-PCTN-100G as OTU2
aggregator.

Table 685 provides information about the multiplexing and mapping schemes.

Table 685: Multiplexing and Mapping Schemes


TDM (muxponder) Multiplexed aggregated client signal mapped into
mode proprietary used OPU2/ ODU2 framing structure acc.
to ITU-T G.7091
Transponder mode Client service mapped into proprietary used OPU2/
ODU2 framing structure acc. to ITU-T G.7091
1. No full standard compliant implementation in all aspects of ITU-T G.709

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

368 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 686 provides information about fault monitoring on the module equipment
level in general.

Table 686: Fault Monitoring Equipment - General


Equipment Alarm Name TL-1 Keyword
Module Equipment removed RMVD
Equipment mismatch MEA-CONDITION
Equipment Fault HWFLT
Voltage Out of Range VOLTANR
FWP-Mismatch (NSA) FWPM-NSA
FWP-Mismatch (SA) FWPM-SA

Table 687 provides information about fault monitoring of the client interfaces.

Table 687: Fault Monitoring Client Interfaces


Layer Alarm Name TL-1 Keyword
Physical layer Laser-fail LASER
Laser degrade (based on bias current) LBCLANR
Loss of signal LOS
SFP/SFP+ Removed RMVD
SFP/SFP+ Physical Mismatch MEA-PHYS
SFP/SFP+ Not Approved MEA-APPROVE
SFP/SFP+ Voltage Out of Range VOLTANR
Auto Shutdown-Forward LKDO-OFF
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

PCS layer Loss of character synchronization1 CHARSYNCH


Autonomous shutdown LKDO-EPC
1. Only supported in framed mode

Table 688 provides information about fault monitoring of the network interface.

Table 688: Fault Monitoring Network Interface


Layer Alarm Name TL-1 Keyword
Physical layer Laser-fail LASER
Laser degrade (based on bias current) LBCLANR
Rx Clock - Loss of Sync RCVCLK
Loss of signal LOS
SFP+ Removed RMVD
SFP+ Physical Mismatch MEA-PHYS
SFP+ Not Approved MEA-APPROVE
SFP+ Voltage Out of Range VOLTANR
OCH//OTU2 OTU-Loss of Frame OTU-LOF
layer
ODU layer Alarm Indication Signal AIS-ODU
Open connection indication OCI-ODU
Lock LCK-ODU
OPU2 layer Auto Shutdown AIS LKDO-AIS-OPU
Generic AIS AIS-OPU

Module and System Specification 369


5TCE-PCN-10GU+AES10G

Table 688: Fault Monitoring Network Interface (Continued)


Proprietary Forward Client Fail LKDO-AIS-VF
aggregate VF FEND Client Fail-AIS AIS-VF
layer Server Signal Failure SSF-VF
Entity Outage SGEO-LASER

Table 689 provides information about performance monitoring on the module


equipment level in general.

Table 689: Performance Monitoring - General


Layer PM Name TL-1 Keyword
Equipment Module temperature - current analogue value T-TEMP-FHT
(Fix threshold crossing alert for module
temperature too high available)

Table 690 provides information about performance monitoring values supported


on the client interfaces in ingress direction.

Table 690: Client Interface Performance Monitoring


Layer PM Name TL-1 Keyword
Physical layer Optical input power Rx - T-OPR-HT
current, low, mean, high T-OPR-LT
(15 min/24 h records available
for PM values except current

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
value; user configurable
threshold crossing alerts for
OPR too high / OPR too low)
Optical output power Tx - T-OPT-FHT
current, low, mean, high T-OPT-FLT
(15 min/24 h records available
for PM values except current
value; fix threshold crossing
alerts for OPT too high / OPT
too low)
SFP/SFP+ T-TEMP-FHT
current analogue value T-TEMP-FLT
(Fix threshold crossing alert for
CFP transceiver temperature
too high/too low available)
Laser bias current level (current LBCL
analogue value)
Latency - measured round trip T-LATENCY-HT
client-to-client T-LATENCY-LT
- current, low, mean, high
(15 min/24 h records available
for PM values except current
value; user configurable
threshold crossing alerts for
latency too high / latency too
low)

370 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 690: Client Interface Performance Monitoring (Continued)


PCS layer - ingress Coding violations 1 CV
direction only (15 min/24 h records available;
user configurable threshold
crossing alerts for CV too high)
Disparity Errors 1 DE
(15 min/24 h records available;
user configurable threshold
crossing alerts for DE too high)
Errored seconds 1 ES
(15 min/24 h records available;
user configurable threshold
crossing alerts for ES too high)
1. CV, DE and ES are supported in framed mode only.

Table 691 provides information about performance monitoring values supported


on the network interface.

Table 691: Network Interface Performance Monitoring


Layer PM Name TL-1 Keyword
Physical layer Optical input power Rx - T-OPR-HT
current, low, mean, high T-OPR-LT
(15 min/24 h records available
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

for PM values except current


value; user configurable
threshold crossing alerts for
OPR too high / OPR too low)
Optical output power Tx - T-OPT-FHT
current, low, mean, high T-OPT-FLT
(15 min/24 h records available
for PM values except current
value; fix threshold crossing
alerts for OPT too high / OPT
too low)
SFP/SFP+ T-TEMP-FHT
current analogue value T-TEMP-FLT
(Fix threshold crossing alert for
CFP transceiver temperature
too high/too low available)
Laser bias current level LBCL
(current analogue value)
Latency - measured round trip T-RNDTRPDLY-HT
network-to-network T-RNDTRPDLY-LT
- current, low, mean, high
(15 min/24 h records available
for PM values except current
value; user configurable
threshold crossing alerts for
latency too high / latency too
low)

Module and System Specification 371


5TCE-PCN-10GU+AES10G

Table 691: Network Interface Performance Monitoring (Continued)


FEC layer Corrected errors CE-FEC
(15 min/24 h records; user
configurable threshold
crossing alerts for CE too high)
Uncorrectable block errors UBE-FEC
(15 min/24 h records; user
configurable threshold
crossing alerts for UBE too
high)
Errored seconds ES-FEC
(15 min/24 h records; user
configurable threshold
crossing alerts for ES too high)
Severely errored seconds SES-FEC
(15 min/24 h records; user
configurable threshold
crossing alerts for SES too
high)
pre-FEC BER BERCE-FEC
(15 min/24 h records; user
configurable threshold
crossing alerts for pre-FEC
BER too high)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
OTU2 layer Errored seconds ES-OTU
(15 min/24 h records; user
configurable threshold
crossing alerts for ES too high)
Severely errored seconds SES-OTU
(15 min/24 h records; user
configurable threshold
crossing alerts for SES too
high)
Unavailable seconds UAS-OTU
(15 min/24 h records; user
configurable threshold
crossing alerts for UAS too
high)
Background block errors BBE-OTU
(15 min/24 h records; user
configurable threshold
crossing alerts for BBE too
high)

372 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 692 provides information about performance monitoring for encryption.

Table 692: Performance Monitoring - Encryption


15 min/24 h records encryption running
encryption running in “degraded mode”
encryption not running
time stamp last successful key exchange
last failed key exchange
last change of Crypto-Officer password
last failed Crypto-Officer password
timer (countdown) remaining session- key lifetime
remaining time running in bypass mode

Table 693 provides information about the loop functionality.

Table 693: Loop Functionality for all Variants


Client ports Facility loop on individual port,
Terminal loop on individual port
Network port Facility loop, Terminal loop 
(Facility and terminal loop on the
network port is only allowed for bypass
applications when encryption is
disabled.)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 694 provides information about protection setting for all variants.

Table 694: Protection Switching


Protection scheme Client channel card protection
Protection switching time < 50 ms
Protection switching criteria Physical signal fail (SF) switching
criteria:
LOS; SSF-VF; AIS-VF; AIS-OPU;
Client SFP removed; Network SFP+
removed
OTN signal fail (SF) switching criteria:
ODU-AIS; ODU-LCK; ODU-OCI
Restoration scheme Versatile switched protection
(RSM-SF, RSM-OLM, VSM)
Restoration time <50 ms

Table 695 provides information about the Embedded Controlled Channels


(ECCs).

Table 695: Embedded Control Channels for all Variants


Notice: One GCC channel is supported per port
Client ports none
Network port GCC0 (1312 kbit/s)

Module and System Specification 373


4WCE-PCN-16GFC

4WCE-PCN-16GFC
The 4WCE-PCN-16GFC is an enterprise type, WDM quad transponder module.
It can have up to four client SFP+ type pluggable interfaces and four network
XFP type pluggable interfaces. The module converts up to four client side
signals to four specific ITU-T compliant network side wavelengths.
The 4WCE-PCN-16GFC contains four independent transponders especially
designed for the transport of 16 G FC services even though 8 G FC and 10 GbE
LAN PHY services are also supported on the client and network interfaces.
Table 696 contains general information about the module and its environment.

Table 696: General Information


Equipment type 4WCE16G
First release 11.2
Width 4 HP
Height 5 HU
Weight (incl. pluggable transceiver) 720 g (1.587 lbs)
Environmental conditions for SH9HU Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Environmental conditions for SH7HU, Operating temperature: +5°C to
SH7HU-R, SH1HU-F/2DC, SH1HU-R +40°C, 5% to 85% relative
humidity (non condensing)
Short-term temperature: -5°C to

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
+40°C, 5% to 90% relative
humidity (non condensing)
Environmental conditions for Operating temperature: +5°C to
SH1HU-HP/2DC, SH1HU-R/PF, +40°C, 5% to 85% relative
SH1HU-HP/E-TEMP/2DC humidity (non condensing)
Short-term temperature: -5°C to
+45°C, 5% to 90% relative
humidity (non condensing)
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 365,630 h
Typ. power consumption (incl. 24 W
transceivers)
Max. power consumption (incl. 30 W
transceivers)
Slot positions SH9HU: slots 3...18,
SH7HU, SH7HU-R: slots 3...18
SH1HU: slots 1, 2
NCU types NCU-II, NCU-II-P

The following table provides information about the client port.

Table 697: Client Port


Number of client ports 4
Type of client port SFP+

374 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

Table 697: Client Port (Continued)


Data rates 8.5 Gbit/s, 10.3125 Gbit/s, 14.025 Gbit/s
Protocols 8G FC, 10 GbE LAN PHY, 16G FC

The following table provides a summary of the supported client SFPs. Please
refer to the specifications of the individual SFP+ type.

Table 698: Supported Client SFP+ Types


850 nm types SFP+/11GU/850I/MM/LC
SFP+/16GFC/850I/MM/LC
SFP+/10G/850I/MM/LC1
1310 nm types SFP+/11GU/1310S/SM/LC
SFP+/16GFC/1310S/SM/LC
SFP+/10G/1310S/SM/LC1
1. For 10GbE only

The following table provides information about the network port.

Table 699: Network Port


Number of network ports 4
Type of network ports XFP
Data rates 8.5 Gbit/s, 10.3125 Gbit/s, 14.025 Gbit/s
Protocols 8G FC, 10 GbE LAN PHY, 16G FC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

The following table provides a summary of the supported network XFPs. Please
refer to the specifications of the individual XFP type.
Table 700: Supported Network XFPs
DWDM types XFP/16GFC/#xxxxxL/SM/LC#Dxx
XFP/16GFC/#19xxxL50/SM/LC
XFP/11G/#19xxxL50/SM/LC
XFP/11G/DCTV/SM/LC
XFP/11G/Dxxxx.xxV/SM/LC#Dxx
CWDM types XFP/11G/CxxxxV/SM/LC

This table contains information about the system performance.

Table 701: System Performance


Max. module delay (without transceivers) 10 ns
Number of regenerators 2 using 4WCE-PCN-16GFC as
back-to-back regenerator
Max. frame size no limitation

Module and System Specification 375


4WCE-PCN-16GFC

This table contains information about synchronization and timing.

Table 702: Synchronization and Timing


Client port Timing Source received network signal
Network port Timing Source received client signal

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

This table shows information about fault monitoring of the module in general.

Table 703: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Temperature alarm;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Client port SFP+ not approved;
Client port SFP+ missing;
Client port SFP+ voltage alarm;

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Client port SFP+ temperature;
Network port XFP not approved;
Network port XFP missing;
Network port XFP voltage alarm;
Network port XFP temperature

This table shows information about fault monitoring of the client ports in general.

Table 704: Fault Monitoring Client Interface - General


Physical layer Laser failure;
Laser degrade (based on bias current);
Loss of signal (LOS);
Autonomous shutdown LKDO-OFF

This table shows information about fault monitoring of the network ports in
general.

Table 705: Fault Monitoring Network Interface - General


Physical layer Laser failure;
Laser degrade (based on bias current);
Loss of signal (LOS)

376 Module and System Specification


Chapter 5 Enterprise Type Channel Modules

The following table provides information about performance monitoring of the


module in general.

Table 706: Performance Monitoring - General


Equipment Module temperature (current
(with fix threshold crossing alert for analogue value)
module temperature too high)

This table shows information about performance monitoring of the client ports in
general.

Table 707: Performance Monitoring Client Interface - General


Physical layer Transmitter bias current (current
(15 min/24 h records available for PM analogue);
values; user configurable threshold Optical input power Rx (current,
crossing alerts for OPR too high/too low low, mean, high);
available; fix threshold crossing alerts for Optical output power Tx (current,
OPT too high/too low available) low, mean, high)
Data layer (15 min/24 h records available) Defect seconds (DS)

This table shows information about performance monitoring of the network ports
in general.

Table 708: Performance Monitoring Network Interface - General


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Physical layer Transmitter bias current (current


(15 min/24 h records available for PM analogue);
values; user configurable threshold Optical input power Rx (current,
crossing alerts for OPR too high/too low low, mean, high);
available; fix threshold crossing alerts for Optical output power Tx (current,
OPT too high/too low available) low, mean, high)
Data layer (15 min/24 h records available) Defect seconds (DS)

The following table provides information about the loop functionality.

Table 709: Loop Functionality


Client port Facility loop (only supported for 8 G FC and
10 GbE LAN PHY)
Network port Facility loop (only supported for 8 G FC and
10 GbE LAN PHY)

This table provides information about protection switching.


Table 710: Protection Switching
Protection scheme Versatile switched protection
(RSM-SF, RSM-OLM, VSM)
Protection switching time < 50 ms

Module and System Specification 377


378
4WCE-PCN-16GFC

Module and System Specification


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Chapter 6

Pluggable Transceivers
This chapter describes pluggable transceivers of the FSP 3000R7.
The descriptions of the discontinued pluggable transceivers can be found in a
former version of the FSP 3000R7 Module and System Specification.
The following sections are provided:
“XFP/16GFC/#xxxxxL/SM/LC#Dxx” on p. 382
“XFP/16GFC/#19xxxL50/SM/LC” on p. 384
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

“XFP/11G/DCTV/SM/LC” on p. 386
“XFP/11G/DCTLNR/SM/LC” on p. 388
“XFP/11G/DCTLN/SM/LC” on p. 390
“XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev. 4.01)” on p. 392
“XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev. 5.01)” on p. 394
“XFP/11G/#19xxxL50/SM/LC” on p. 396
“XFP/OTN11G/#19xxxV/SM/LC” on p. 398
“XFP/8G/#xxxxxL/SM/LC#Dxx” on p. 400
“XFP/11G/CxxxxL/SM/LC” on p. 402
“XFP/11G/CxxxxV/SM/LC” on p. 404
“XFP/8G/CxxxxL/SM/LC” on p. 406
“XFP/10G/850I/MM/LC (HW Rev. 1.01)” on p. 408
“XFP/10G/850I/MM/LC (HW Rev. 2.01)” on p. 409
“XFP/11G/1310S/SM/LC” on p. 410
“XFP/11G/1550L/SM/LC” on p. 411
“XFP/8G/1310S/SM/LC” on p. 412
“XFP/8G/850I/MM/LC” on p. 413
“SFP+/16GFC/1310S/SM/LC” on p. 414
“SFP+/16GFC/850I/MM/LC” on p. 415

Module and System Specification 379


“SFP+CDR/10GU/1550L/SM/LC” on p. 416
“SFP+CDR/10GU/850I/MM/LC” on p. 417
“SFP+CDR/11GU/1310S/SM/LC” on p. 418
“SFP+CDR/11GU/CxxxxL/SM/LC” on p. 420
“SFP+CDR/11GU/CxxxxS/SM/LC” on p. 422
“SFP+/10G/1310S/SM/LC” on p. 424
“SFP+/10G/850I/MM/LC” on p. 425
“SFP+/11GU/#19xxxL50/SM/LC” on p. 426
“SFP+/11GU/CxxxxL/SM/LC” on p. 428
“SFP+/11GU/1310S/SM/LC” on p. 430
“SFP+/11GU/850I/MM/LC” on p. 431
“SFP+/8GU/1310S/SM/LC” on p. 433
“SFP+/8GU/850I/MM/LC” on p. 434
“SFP/4GU/Dxxxx.xxV/SM/LC#Dxx” on p. 435
“SFP/4GU/CxxxxV/SM/LC (HW Rev. 2.01)” on p. 436
“SFP/4GU/CxxxxV/SM/LC (HW Rev. 3.01)” on p. 437
“SFP/4GU/1310S/SM/LC” on p. 438
“SFP/4GU/850I/MM/LC” on p. 439

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
“SFP/4GU/CxxxxL/SM/LC” on p. 440
“SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx” on p. 442
“SFP/2G5U/CxxxxV/SM/LC” on p. 444
“SFP/2G5U/CxxxxL/SM/LC” on p. 446
“SFP/2G5U/1310S/SM/LC (HW Rev. 2.01)” on p. 447
“SFP/2G5U/1310L/SM/LC” on p. 448
“SFP/3GSDI/#xxxxxV/SM/LC” on p. 449
“SFP/3GSDI/ELECTRICAL/DIN” on p. 451
“SFP/3GSDI/ELECTRICAL/HBNC” on p. 452
“SFP/HS/1310S/SM/LC” on p. 453
“SFP/CL/1310I/SM/LC” on p. 454
“SFP/2G1/850I/MM/LC” on p. 455
“SFP/GBE/1310S/SM/LC/TIN” on p. 457
“SFP/GBE/1310L/SM/LC/TIN” on p. 458
“SFP/GBE/1550V/SM/LC/TIN” on p. 459
“SFP/GBE/850I/MM/LC/TIN” on p. 460
“SFP/GBE/B1310S/SM/LC” on p. 461
“SFP/GBE/B1490S/SM/LC” on p. 462
“SFP/GBE/B1310L/SM/LC” on p. 463

380 Module and System Specification


Chapter 6 Pluggable Transceivers

“SFP/GBE/B1490L/SM/LC” on p. 464
“SFP/GBE/Electrical/RJ45” on p. 465
“SFP/FE/C1490U/SM/LC” on p. 466
“SFP/FE/C1510U/SM/LC” on p. 467
“SFP/FE/C1490V/SM/LC” on p. 468
“SFP/FE/C1510V/SM/LC” on p. 469
“SFP/FE/D1528.77E/SM/LC” on p. 470
“SFP/FE/Dxxxx.xxV/SM/LC” on p. 471
“CFP/112G/LR10R/SM/LC” on p. 472
“CFP/112G/LR4/SM/LC” on p. 475
“CFP/103G/SR10/MM/MPO” on p. 478
“CFP/4x28G/#19xxx-#19xxxL/SM/LC” on p. 480
“CFP/4x28G/#DCTL/SM/LC” on p. 483
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 381


XFP/16GFC/#xxxxxL/SM/LC#Dxx

XFP/16GFC/#xxxxxL/SM/LC#Dxx
The XFP/16GFC/#xxxxxL/SM/LC#Dxx is an MSA-compliant pluggable trans-
ceiver for data rates of 4.25 Gbit/s, 8.5 Gbit/s and 14.025 Gbit/s. It is used for
bidirectional communication over single-mode fiber.
This transceiver is operating at DWDM wavelengths according to ITU-T G.694.1
and provides digital diagnostic monitoring of operating parameters such as opti-
cal input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.

Table 711: Technical Data


Equipment type XFP-D
First release 11.2
Module type XFP
Weight 50 g (0.11 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 2,410,826 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 4.25 Gbit/s, 8.5 Gbit/s, 14.025 Gbit/s
Protocols 4G FC, 8G FC, 16G FC
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelength range 41 channels, 100 GHz spacing in 
C band acc. to ITU-T G.694.1
Wavelength stability (operating) +/- 125 pm
Min. extinction ratio 8.2 dB
Min. sidemode suppression ratio 35 dB
Receiver wavelength range 1500 nm ... 1600 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -13 dBm ... -1 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -18 dBm ... 0 dBm
Optimum dispersion load range 0 ps/nm ... +400ps/nm
Dispersion load range with 2 dB -400 ps/nm... 0 ps/nm and 
OSNR penalty in case of amplified +400 ps/nm ... +700 ps/nm
links or 2 dB receive power penalty
in case of unamplified links
OSNR penalty at 10 ps PMD for 1 dB (outage probability 4x10-5)
BER > 10-5

382 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 711: Technical Data (Continued)


Bit error ratio < 10-12 at 27 dB OSNR (0.1 nm)
Max. module delay < 3 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 383


XFP/16GFC/#19xxxL50/SM/LC

XFP/16GFC/#19xxxL50/SM/LC
The XFP/16GFC/#19xxxL50/SM/LC is an MSA-compliant pluggable transceiver
for data rates of 4.25 Gbit/s, 8.5 Gbit/s and 14.025 Gbit/s. It is used for bidirec-
tional communication over single-mode fiber.
This transceiver is operating at DWDM wavelengths according to ITU-T G.694.1
and provides digital diagnostic monitoring of operating parameters such as opti-
cal input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.

Table 712: Technical Data


Equipment type XFP-D
First release 12.1
Module type XFP
Weight 50 g (0.11lbs)
Maximum power consumption 3.5 W
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
office environments only.
MTBF at 25°C ambient temperature 2,410,826 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 4.25 Gbit/s, 8.5 Gbit/s, 14.025 Gbit/s
Protocols 4G FC, 8G FC, 16G FC
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelength range 96 channels, 50 GHz spacing in 
C band acc. to ITU-T G.694.1
Wavelength stability (operating) 60 pm operating
Min. extinction ratio 8.2 dB
Min. sidemode suppression ratio 35 dB
Receiver wavelength range 1500 nm ... 1600 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -12 dBm ... 0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -14 dBm ... +3 dBm
Optimum dispersion load range -100 ps/nm ... +100 ps/nm
Dispersion load range with 1 dB -200 ps/nm... -100 ps/nm and 
OSNR penalty +100 ps/nm ... +400 ps/nm
Dispersion load range with 2 dB -400 ps/nm... -200 ps/nm and 
OSNR penalty +400 ps/nm ... +700 ps/nm

384 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 712: Technical Data (Continued)


OSNR penalty at 10 ps PMD for 1 dB (outage probability 4x10-5)
BER > 10-5
Bit error ratio < 10-12 at 27 dB OSNR (0.1 nm)
Max. module delay < 3 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 385


XFP/11G/DCTV/SM/LC

XFP/11G/DCTV/SM/LC
The XFP/11G/DCTV/SM/LC is a Multi-Protocol Optical XFP that provides a high
speed serial link at data rates from 9.95 Gbit/s to 11.35 Gbit/s. It is used for
bidirectional communication over single-mode fiber.
The transmitter is fully tunable to any of the C-band channels. Each channel can
be tuned in the system management by using the NE management tools.
It is intended for use in FSP 3000R7 modules with tunable XFP interface cages.
Proper functionality and valid certification of transponder modules can be
guaranteed with XFP types approved by ADVA Optical Networking only.

Table 713: Technical Data


Equipment type XFPT-D
First release 9.3
Module type XFP
Weight 50 g (0.11 lbs)
Environmental conditions Telcordia SR-3580 level 3
(NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 2,600,000 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s, 10.6642 Gbit/s,
10.709 Gbit/s, 11.0032 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s,
11.3176 Gbit/s
Protocols STM-64/OC-192, 10 G FC,
10 GbE LAN PHY,
10 GbE WAN PHY, OTU1e,
OTU2, OTU2e
Transmitter output power range -1 dBm ... +3 dBm
Transmitter wavelength range 81 channels, 50 GHz spacing in C
band acc. to ITU-T G.698.1
(tunable)
Wavelength stability (operating) +/- 60 pm
Min. extinction ratio 8 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1260 nm ... 1610 nm
Max. receiver reflectance 27 dB
Receiver dynamic range for OSNR  -22 dBm ... -7 dBm
> 30 dB (0.1 nm)

386 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 713: Technical Data (Continued)


Receiver dynamic range for OSNR  -20 dBm ... -7 dBm
< 30 dB (0.1 nm)
OPR/OPT accuracy +/- 3 dB
OPR measurement range -22 dBm ... -4 dBm
Optimum dispersion load range +300 ps/nm ... +1000 ps/nm
Dispersion load range with 1 dB OSNR -100 ps/nm ... +300 ps/nm and
penalty +1000 ps/nm ... +1300 ps/nm
Dispersion load range with 2 dB OSNR -400 ps/nm ... -100 ps/nm and 
penalty +1300 ps/nm ... +1500 ps/nm
OSNR penalty at 10 ps PMD for BER  1 dB (outage probability 4x10-5)
> 10-5
OSNR penalty at 7 ps PMD for BER  1 dB (outage probability 4x10-5)
< 10-12
OSNR penalty at 11.1 Gbit/s data rate 2 dB
OSNR penalty at 11.3 Gbit/s data rate 3 dB
Bit error ratio < 10-12 at 25 dB OSNR (0.1 nm)
< 10-9 at 23 dB OSNR (0.1 nm)
< 10-5 at 19 dB OSNR (0.1 nm)
< 10-4 at 17 dB OSNR (0.1 nm)
< 10-3 at 15 dB OSNR (0.1 nm)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Max. module delay < 50 ns

Module and System Specification 387


XFP/11G/DCTLNR/SM/LC

XFP/11G/DCTLNR/SM/LC
The XFP/11G/DCTLNR/SM/LC is an Multi-Protocol Optical XFP that provides a
high speed serial link at data rates from 9.95 Gbit/s to 11.317 Gbit/s. It is used
for bidirectional communication over single-mode fiber. This tunable DWDM
XFP transceiver is an MSA-compliant pluggable transceiver, which complies
with the ITU-T G.698.1 SD100S1-2D for the C band in a wavelength grid of
50 GHz.
The transmitter is fully tunable to any of the C-band channels. Each channel can
be tuned in the system management by using the NE management tools.
The XFP/11G/DCTLNR/SM/LC offers a high extinction ratio and thus it is
suitable for links with a high amount of amplifiers and low OSNR. It features
reduced set of technical data in comparison to other FSP 3000R7 modules also
offering high extinction ratio.
This transceiver is intended for use in FSP 3000R7 modules with tunable XFP
interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with XFP types approved by ADVA Optical
Networking only.

Table 714: Technical Data


Equipment type XFPTLN-D
First release 10.3

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Module type XFP
Weight 50 g (0.11 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 1,421,464 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s, 10.6642 Gbit/s,
10.709 Gbit/s, 11.0032 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s,
11.3176 Gbit/s
Protocols STM-64/OC-192, 10G FC,
10 GbE LAN PHY,
10 GbE WAN PHY, OTU1e, OTU2,
OTU2e
Transmitter output power range -1 dBm ... +3 dBm
Transmitter wavelength range 81 channels, 50 GHz spacing in C
band acc. to ITU-T G.698.1
(tunable)
Wavelength stability (operating) +/- 60 pm

388 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 714: Technical Data (Continued)


Min. extinction ratio 12 dB
Min. sidemode suppression ratio 35 dB
Receiver wavelength range 1260 nm ... 1610 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -17 dBm to 0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -21 dBm ... +3 dBm
Optimum dispersion load range -300 ps/nm ... +300 ps/nm
Dispersion load range with 1 dB -500 ps/nm ... -300 ps/nm and 
OSNR penalty +300 ps/nm ... +500 ps/nm
Dispersion load range with 2 dB -700 ps/nm ... -500 ps/nm and 
OSNR penalty +500 ps/nm ... +700 ps/nm
OSNR penalty at -18 dBm optical 1 dB
input power
OSNR penalty at 10 ps PMD for BER  1 dB (outage probability 4x10-5)
> 10-5
OSNR penalty at 7 ps PMD for BER  1 dB (outage probability 4x10-5)
< 10-12
OSNR penalty at 11.1 Gbit/s data rate 1 dB
OSNR penalty at 11.3 Gbit/s data rate 2 dB
Bit error ratio < 10-12 at 23 dB OSNR (0.1 nm)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Pre-Fec Bit error ratio1 < 10-5 at 17 dB OSNR (0.1 nm)


< 10-4 at 15 dB OSNR (0.1 nm)
< 10-3 at 14 dB OSNR (0.1 nm)
Max. module delay < 50 ns
1. The performance at low OSNR values and bit error ratios above 10-4 can be
achieved with enabled FEC and adaptive threshold control (ATC) of the
respective channel module only. For adjusting the threshold the ATC may
need up to 10 minutes.

Module and System Specification 389


XFP/11G/DCTLN/SM/LC

XFP/11G/DCTLN/SM/LC
The XFP/11G/DCTLN/SM/LC is an Multi-Protocol Optical XFP that provides a
high speed serial link at data rates from 9.95 Gbit/s to 11.317 Gbit/s. It is used
for bidirectional communication over single-mode fiber. This tunable DWDM
XFP transceiver is an MSA-compliant pluggable transceiver, which complies
with the ITU-T G.698.1 SD100S1-2D for the C band in a wavelength grid of 
50 GHz.
The transmitter is fully tunable to any of the C-band channels. Each channel can
be tuned in the system management by using the NE management tools.
The XFP/11G/DCTLN/SM/LC offers a high extinction ratio and thus it is suitable
for links with a high amount of amplifiers and low OSNR.
This transceiver is intended for use in FSP 3000R7 modules with tunable XFP
interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with XFP types approved by ADVA Optical
Networking only.

Table 715: Technical Data


Equipment type XFPTLN-D
First release 11.1
Module type XFP
Weight 50 g (0.11 lbs)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Environmental conditions Operating temperature: +5°C … +40°C
5% ... 85% relative humidity
(non-condensing)

Short-term temperature: -5°C … +45°C


5% ... 90% relative humidity
(non-condensing)
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled office
environments only.
MTBF at 25°C ambient 3,500,000 h
temperature
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s, 10.6642 Gbit/s,
10.709 Gbit/s, 11.0032 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s,
11.3176 Gbit/s
Protocols STM-64/OC-192, 10 GbE LAN PHY,
10 GbE WAN PHY, 10 G FC, OTU2,
OTU1e, OTU2e
Transmitter output power range 0 dBm ... +3 dBm
Transmitter wavelength range 81 channels, 50 GHz spacing in C band
acc. to ITU-T G.698.1 (tunable)

390 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 715: Technical Data (Continued)


Wavelength stability (operating) +/- 60 pm
Min. extinction ratio 11 dB at 10.7092 Gbit/s
Min. sidemode suppression ratio 35 dB
Receiver wavelength range 1260 nm ... 1610 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -16 dBm to 0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -21 dBm ... +3 dBm
Optimum dispersion load range -300 ps/nm ... +300 ps/nm
Dispersion load range with 1 dB -500 ps/nm ... -300 ps/nm and 
OSNR penalty +300 ps/nm ... +500 ps/nm
Dispersion load range with 2 dB -700 ps/nm ... -500 ps/nm and 
OSNR penalty +500 ps/nm ... +700 ps/nm
OSNR penalty at -18 dBm optical 1 dB
input power
OSNR penalty at 10 ps PMD for 1 dB (outage probability 4x10-5)
BER > 10-5
OSNR penalty at 7 ps PMD for 1 dB (outage probability 4x10-5)
BER < 10-12
OSNR penalty at 11.1 Gbit/s data 1 dB
rate
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

OSNR penalty at 11.3 Gbit/s data 2 dB


rate
Bit error ratio < 10-12 at 23 dB OSNR (0.1 nm)
Pre-Fec Bit error ratio1 < 10-5 at 15 dB OSNR (0.1 nm)
< 10-4 at 13.5 dB OSNR (0.1 nm)
< 10-3 at 12 dB OSNR (0.1 nm)
Max. module delay < 50 ns
1. The performance at low OSNR values and bit error ratios above 10-4 can be
achieved with enabled FEC and adaptive threshold control (ATC) of the
respective channel module only. For adjusting the threshold the ATC may
need up to 10 minutes.

Module and System Specification 391


XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev. 4.01)

XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev.


4.01)

The XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev. 4.01) is an MSA-compliant


pluggable transceiver for 11 Gbit/s data rates and bidirectional communication
over single-mode fiber. It is operating at DWDM wavelengths according to ITU-T
G.694.1 and it provides digital diagnostic monitoring of operating parameters
such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.

Table 716: Technical Data


Equipment type XFP-D
First release 9.3
Module type XFP
Weight 50 g (0.11 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 924,214 h

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s, 10.6642 Gbit/s,
10.709 Gbit/s, 11.0032 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s,
11.3176 Gbit/s
Protocols STM-64/OC-192, 10 GbE LAN PHY,
10 GbE WAN PHY, 10 G FC, OTU2,
OTU1e, OTU2e
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelength range 41 channels, 100 GHz spacing in C
band acc. to ITU-T G.694.1
Wavelength stability (operating) +/- 100 pm
Min. extinction ratio 8 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1260 nm ... 1610 nm
Max. receiver reflectance 27 dB
Receiver dynamic range at OSNR  -23 dBm ... -7 dBm
> 30 dB
Receiver dynamic range at OSNR  -20 dBm ... -7 dBm
< 30 dB
OPR/OPT accuracy +/- 3 dB

392 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 716: Technical Data (Continued)


OPR measurement range -23 dBm ... -6 dBm
Optimum dispersion load range +100 ps/nm ... +800 ps/nm
Dispersion load range with 1 dB -200 ps/nm ... +100 ps/nm and 
OSNR penalty +800 ps/nm ... +1100 ps/nm
Dispersion load range with 2 dB -500 ps/nm ... -200 ps/nm and 
OSNR penalty +1100 ps/nm ... +1400 ps/nm
OSNR penalty at 10 ps PMD for BER  1 dB (outage probability 4x10-5)
> 10-5
OSNR penalty at 7 ps PMD for BER  1 dB (outage probability 4x10-5)
< 10-12
OSNR penalty at 11.1 Gbit/s data 2 dB
rate
OSNR penalty at 11.3 Gbit/s data 3 dB
rate
Bit error ratio < 10-12 at 25 dB OSNR (0.1 nm)
< 10-9 at 23 dB OSNR (0.1 nm)
< 10-5 at 19 dB OSNR (0.1 nm)
< 10-4 at 17 dB OSNR (0.1 nm)
< 10-3 at 15 dB OSNR (0.1 nm)
Max. module delay < 3 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 393


XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev. 5.01)

XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev.


5.01)

The XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev. 5.01) is an MSA-compliant


pluggable transceiver for 11 Gbit/s data rates and bidirectional communication
over single-mode fiber. It is operating at DWDM wavelengths according to ITU-T
G.694.1 and it provides digital diagnostic monitoring of operating parameters
such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.

Table 717: Technical Data


Equipment type XFP-D
First release 9.3
Module type XFP
Weight 50 g (0.11 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 924,214 h

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s, 10.6642 Gbit/s,
10.709 Gbit/s, 11.0032 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s,
11.3176 Gbit/s
Protocols STM-64/OC-192, 10 GbE LAN PHY,
10 GbE WAN PHY, 10 G FC, OTU2,
OTU1e, OTU2e
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelength range 41 channels, 100 GHz spacing in C
band acc. to ITU-T G.694.1
Wavelength stability (operating) +/- 100 pm
Min. extinction ratio 8 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1260 nm ... 1610 nm
Max. receiver reflectance 27 dB
Receiver dynamic range at OSNR  -23 dBm ... -7 dBm
> 30 dB
Receiver dynamic range at OSNR  -20 dBm ... -7 dBm
< 30 dB
OPR/OPT accuracy +/- 3 dB

394 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 717: Technical Data (Continued)


OPR measurement range -23 dBm ... -6 dBm
Optimum dispersion load range +100 ps/nm ... +800 ps/nm
Dispersion load range with 1 dB -200 ps/nm ... +100 ps/nm and 
OSNR penalty +800 ps/nm ... +1100 ps/nm
Dispersion load range with 2 dB -500 ps/nm ... -200 ps/nm and 
OSNR penalty +1100 ps/nm ... +1400 ps/nm
OSNR penalty at 10 ps PMD for BER  1 dB (outage probability 4x10-5)
> 10-5
OSNR penalty at 7 ps PMD for BER  1 dB (outage probability 4x10-5)
< 10-12
OSNR penalty at 11.1 Gbit/s data 2 dB
rate
OSNR penalty at 11.3 Gbit/s data 3 dB
rate
Bit error ratio < 10-12 at 25 dB OSNR (0.1 nm)
< 10-9 at 23 dB OSNR (0.1 nm)
< 10-5 at 19 dB OSNR (0.1 nm)
< 10-4 at 17 dB OSNR (0.1 nm)
< 10-3 at 15 dB OSNR (0.1 nm)
Max. module delay < 50 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 395


XFP/11G/#19xxxL50/SM/LC

XFP/11G/#19xxxL50/SM/LC
The XFP/11G/#19xxxL50/SM/LC is an MSA-compliant pluggable transceiver
for 11 Gbit/s data rates and bidirectional communication over single-mode fiber.
It is operating at DWDM wavelengths according to ITU-T G.694.1 and it
provides digital diagnostic monitoring of operating parameters such as optical
input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.

Table 718: Technical Data


Equipment type XFP-D
First release 12.1
Module type XFP
Weight 50 g (0.11 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 81,037 h

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s, 10.6642 Gbit/s,
10.709 Gbit/s, 11.0032 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s,
11.3176 Gbit/s
Protocols STM-64/OC-192, 10 GbE LAN PHY,
10 GbE WAN PHY, 10 G FC, OTU2,
OTU1e, OTU2e
Transmitter output power range -1 dBm ... +4 dBm
Transmitter wavelength range 96 channels, 50 GHz spacing in C
band acc. to ITU-T G.694.1
48 channels, 100 GHz spacing in C
band acc. to ITU-T G.694.1
Wavelength stability (operating) 12GHz
Min. extinction ratio 8.2 dB
Min. sidemode suppression ratio 35 dB
Receiver wavelength range 1270 nm ... 1600 nm
Max. receiver reflectance 26 dB
Receiver dynamic range -14 dBm ... 0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -18 dBm ... +2 dBm
Optimum dispersion load range -300 ps/nm ... +300 ps/nm

396 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 718: Technical Data (Continued)


Dispersion load range with 1 dB -500 ps/nm ... -300 ps/nm and 
OSNR penalty +300 ps/nm ...+500 ps/nm
Dispersion load range with 2 dB -700 ps/nm ... -500 ps/nm and 
OSNR penalty +500 ps/nm ... +700 ps/nm
OSNR penalty at 10 ps PMD for BER 1 dB (outage probability 4x10-5)
> 10-5
OSNR penalty at 7 ps PMD for BER 1 dB (outage probability 4x10-5)
< 10-12
OSNR penalty at 11.1 Gbit/s data 1 dB
rate
OSNR penalty at 11.3 Gbit/s data 2 dB
rate
Bit error ratio < 10-12 at 25 dB OSNR (0.1 nm)
< 10-5 at 19 dB OSNR (0.1 nm)
< 10-4 at 17 dB OSNR (0.1 nm)
< 10-3 at 15 dB OSNR (0.1 nm)
Max. module delay 50 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 397


XFP/OTN11G/#19xxxV/SM/LC

XFP/OTN11G/#19xxxV/SM/LC
The XFP/OTN11G/#19xxxV/SM/LC is an MSA-compliant pluggable transceiver
for 11 Gbit/s data rates and bidirectional communication over single-mode fiber.
It is operating at DWDM wavelengths according to ITU-T G.694.1 and it
provides digital diagnostic monitoring of operating parameters such as optical
input power, temperature or laser bias. This transceiver supports OTU2e
services according to ITU-T G.709 to enable GFEC.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.

Table 719: Technical Data


Equipment type XFP-OTN-D
First release 11.1
Module type XFP
Weight 26 g (0.06 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according IP20. Use in a pollution degree 2
to IEC 60529 environment and indoor controlled office
environments only.
MTBF at 25°C ambient 10,989,010 h

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
temperature
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 11.0957 Gbit/s
Protocols OTU2e (OTU2LAN with stuffing)
Transmitter output power 0 dBm ... +3 dBm
range
Transmitter wavelength range 41 channels, 100 GHz spacing in 
C band acc. to ITU-T G.694.1
Wavelength stability +/- 100 pm
(operating)
Min. extinction ratio 9 dB
Min. sidemode suppression 30 dB
ratio
Receiver wavelength range 1527 nm ... 1567 nm
Max. receiver reflectance 27 dB
Receiver dynamic range at -25 dBm ... -7 dBm over the entire
OSNR > 33 dB dispersion load range
Receiver dynamic range at -18 dBm ... -7 dBm
OSNR > 16 dB
OPR/OPT accuracy +/- 3 dB
OPR measurement range -28 dBm ... -4 dBm
Min. dispersion load -700 ps/nm

398 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 719: Technical Data (Continued)


Optimum dispersion load 0 ps/nm
Max. dispersion load 1300 ps/nm
Dispersion load range versus • 0 ps/nm to +250 ps/nm at 16 dB
minimum required OSNR for a
• +250 ps/nm to +400 ps/nm at 16.5 dB
Post FEC bit error ratio < 10-12
• -400 ps/nm to 0 ps/nm and 
+400 ps/nm to +900 ps/nm at 18 dB
• -700 ps/nm to -400 ps/nm and 
+900 ps/nm to +1300 ps/nm at 20 dB
OSNR PMD penalty 1 dB at 30 ps (outage probability 8 x 10-5)
Max. module delay 10 µs
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 399


XFP/8G/#xxxxxL/SM/LC#Dxx

XFP/8G/#xxxxxL/SM/LC#Dxx
The XFP/8G/#xxxxxL/SM/LC#Dxx is an MSA-compliant pluggable transceiver
for 4.25 Gbit/s and 8.5 Gbit/s data rates and bidirectional communication over
single-mode fiber. It is operating at DWDM wavelengths according to ITU-T
G.694.1 and provides digital diagnostic monitoring of operating parameters
such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.

Table 720: Technical Data


Equipment type XFP-D
First release 9.2
Module type XFP
Weight 50 g (0.11 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 668,972 h

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 4.25 Gbit/s, 8.5 Gbit/s
Protocols 4G FC, 8G FC
Transmitter output power range -0.5 dBm ... +4 dBm
Transmitter wavelength range 41 channels, 100 GHz spacing in 
C band acc. to ITU-T G.694.1
Wavelength stability (operating) +/- 100 pm
Min. extinction ratio 8 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1270 nm ... 1600 nm
Max. receiver reflectance 27 dB
Receiver dynamic range at OSNR  -22 dBm ... -7 dBm
> 30 dB
Receiver dynamic range at OSNR  -20 dBm ... -7 dBm
> 25 dB
OPR/OPT accuracy +/- 3 dB
OPR measurement range -22 dBm ... -4 dBm
Optimum dispersion load range +300 ps/nm ... +600 ps/nm
Dispersion load range with 1 dB 0 ps/nm ... +300 ps/nm and 
OSNR penalty +600 ps/nm ... +900 ps/nm

400 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 720: Technical Data (Continued)


Dispersion load range with 2 dB -300 ps/nm ... 0 ps/nm and 
OSNR penalty +900 ps/nm ... +1200 ps/nm
OSNR penalty at 10 ps PMD 1 dB
Bit error ratio < 10-12
Max. module delay < 3 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 401


XFP/11G/CxxxxL/SM/LC

XFP/11G/CxxxxL/SM/LC
The XFP/11G/CxxxxL/SM/LC is an MSA-compliant pluggable transceiver for 
11 Gbit/s data rates and bidirectional communication over single-mode fiber. It
is operating at CWDM wavelengths according to ITU-T G.694.2 and it provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.

Table 721: Technical Data


Equipment type XFP-C
First release 8.2
Module type XFP
Weight 50 g (0.11 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled office
environments only.
MTBF at 25°C ambient 2,386,635 h
temperature

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s, 10.51875
Gbit/s, 10.6642 Gbit/s, 10.709 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s
Protocols STM-64/OC-192, 10 GbE LAN PHY, 
10 GbE WAN PHY, 10G FC, OTU2,
OTU1e, OTU2e
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelength range 1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm, 1611 nm
Min. extinction ratio 8 dB
Min. sidemode suppression ratio 35 dB
Receiver wavelength range 1260 nm ... 1610 nm
Max. receiver reflectance 27 dB
Receiver dynamic range without -16 dBm ... -9 dBm
FEC
OPR/OPT accuracy +/- 3 dB
OPR measurement range -16 dBm ... -6 dBm

402 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 721: Technical Data (Continued)


Min. dispersion load -260 ps/nm for XFP/11G/C1470L/SM/LC
-280 ps/nm for XFP/11G/C1490L/SM/LC
-300 ps/nm for XFP/11G/C1510L/SM/LC
-320 ps/nm for XFP/11G/C1530L/SM/LC
-340 ps/nm for XFP/11G/C1550L/SM/LC
-360 ps/nm for XFP/11G/C1570L/SM/LC
-380 ps/nm for XFP/11G/C1590L/SM/LC
-400 ps/nm for XFP/11G/C1610L/SM/LC
Optimum dispersion load 0 ps/nm
Max. dispersion load 520 ps/nm for XFP/11G/C1470L/SM/LC
560 ps/nm for XFP/11G/C1490L/SM/LC
600 ps/nm for XFP/11G/C1510L/SM/LC
640 ps/nm for XFP/11G/C1530L/SM/LC
680 ps/nm for XFP/11G/C1550L/SM/LC
720 ps/nm for XFP/11G/C1570L/SM/LC
760 ps/nm for XFP/11G/C1590L/SM/LC
800 ps/nm for XFP/11G/C1610L/SM/LC
Max. power penalty at dispersion 3 dB at max. dispersion load
(regarding receiver sensitivity) 3 dB at min. dispersion load
Bit error ratio < 10-12
Max. module delay 50 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 403


XFP/11G/CxxxxV/SM/LC

XFP/11G/CxxxxV/SM/LC
The XFP/11G/CxxxxV/SM/LC is an MSA-compliant pluggable transceiver for 
11 Gbit/s data rates and bidirectional communication over single-mode fiber. It
is operating at CWDM wavelengths according to ITU-T G.694 and it provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.

Table 722: Technical Data


Equipment type XFP-C
First release 8.1
Module type XFP
Weight 50 g (0.11 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled office
environments only.
MTBF at 25°C ambient 2,444,988 h
temperature

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s, 10.51875
Gbit/s, 10.6642 Gbit/s, 10.709 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s
Protocols STM-64/OC-192, 10 GbE LAN PHY, 
10 GbE WAN PHY, 10 G FC, OTU2,
OTU1e, OTU2e
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelength range 1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm, 1611 nm
Min. extinction ratio 8 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1260 nm ... 1610 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -22 dBm ... -9 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -22 dBm ... -6 dBm

404 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 722: Technical Data (Continued)


Min. dispersion load -455 ps/nm for XFP/11G/C1470V/SM/LC
-490 ps/nm for XFP/11G/C1490V/SM/LC
-525 ps/nm for XFP/11G/C1510V/SM/LC
-560 ps/nm for XFP/11G/C1530V/SM/LC
-595 ps/nm for XFP/11G/C1550V/SM/LC
-630 ps/nm for XFP/11G/C1570V/SM/LC
-665 ps/nm for XFP/11G/C1590V/SM/LC
-700 ps/nm for XFP/11G/C1610V/SM/LC
Optimum dispersion load 0 ps/nm
Max. dispersion load 910 ps/nm for XFP/11G/C1470V/SM/LC
980 ps/nm for XFP/11G/C1490V/SM/LC
1050 ps/nm for XFP/11G/C1510V/SM/LC
1120 ps/nm for XFP/11G/C1530V/SM/LC
1190 ps/nm for XFP/11G/C1550V/SM/LC
1260 ps/nm for XFP/11G/C1570V/SM/LC
1330 ps/nm for XFP/11G/C1590V/SM/LC
1400 ps/nm for XFP/11G/C1610V/SM/LC
Max. power penalty at dispersion 3 dB at min. dispersion load
(regarding receiver sensitivity) 3 dB at max. dispersion load
Bit error ratio < 10-12
Max. module delay 50 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 405


XFP/8G/CxxxxL/SM/LC

XFP/8G/CxxxxL/SM/LC
The XFP/8G/CxxxxL/SM/LC is an MSA-compliant pluggable transceiver for
4.25 Gbit/s and 8.5 Gbit/s data rates and bidirectional communication over
single-mode fiber. It is operating at CWDM wavelengths according to ITU-T
G.694.2 and it provides digital diagnostic monitoring of operating parameters
such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.

Table 723: Technical Data


Equipment type XFP-C
First release 11.1
Module type XFP
Weight 50 g (0.11 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled office
environments only.
MTBF at 25°C ambient 3,086,419 h
temperature

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 4.25 Gbit/s, 8.5 Gbit/s
Protocols 4G FC, 8G FC
Transmitter output power range -1 dBm ... +4 dBm
Transmitter wavelength range 1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm, 1611 nm
Min. extinction ratio 8.2 dB
Min. sidemode suppression ratio 35 dB
Receiver wavelength range 1260 nm ... 1610 nm
Max. receiver reflectance 12 dB
Receiver dynamic range without -16 dBm ... -1 dBm
FEC
OPR/OPT accuracy +/- 3 dB
OPR measurement range -18 dBm ... +1 dBm
Min. dispersion load -260 ps/nm for XFP/8G/C1470L/SM/LC
-280 ps/nm for XFP/8G/C1490L/SM/LC
-300 ps/nm for XFP/8G/C1510L/SM/LC
-320 ps/nm for XFP/8G/C1530L/SM/LC
-340 ps/nm for XFP/8G/C1550L/SM/LC
-360 ps/nm for XFP/8G/C1570L/SM/LC
-380 ps/nm for XFP/8G/C1590L/SM/LC
-400 ps/nm for XFP/8G/C1610L/SM/LC

406 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 723: Technical Data (Continued)


Optimum dispersion load 0 ps/nm
Max. dispersion load 520 ps/nm for XFP/8G/C1470L/SM/LC
560 ps/nm for XFP/8G/C1490L/SM/LC
600 ps/nm for XFP/8G/C1510L/SM/LC
640 ps/nm for XFP/8G/C1530L/SM/LC
680 ps/nm for XFP/8G/C1550L/SM/LC
720 ps/nm for XFP/8G/C1570L/SM/LC
760 ps/nm for XFP/8G/C1590L/SM/LC
800 ps/nm for XFP/8G/C1610L/SM/LC
Max. power penalty at dispersion 3 dB at max. dispersion load
(regarding receiver sensitivity) 3 dB at min. dispersion load
Bit error ratio < 10-12
Max. module delay <3 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 407


XFP/10G/850I/MM/LC (HW Rev. 1.01)

XFP/10G/850I/MM/LC (HW Rev. 1.01)

The XFP/10G/850I/MM/LC (HW Rev. 1.01) is an MSA-compliant pluggable


transceiver for 10 Gbit/s data rates and bidirectional communication over
multimode fiber. It is operating at a wavelength of 850 nm and it provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.

Table 724: Technical Data


Equipment type XFP-G
First release 7.0
Module type XFP
Weight 50 g (0.11 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 5,707,437 h
Optical connector type Duplex LC

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmitter fiber type MM 62.5 µm
Receiver fiber type MM 62.5 µm
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s
Protocols 10 GbE LAN PHY, 10 GbE WAN PHY,
10G FC
Transmitter output power range -8 dBm ... -1 dBm
Transmitter wavelength range 840 nm ... 860 nm
Min. extinction ratio 3 dB
Receiver wavelength range 840 nm ... 860 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -9.9 dBm ... -1 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -11 dBm ... 2 dBm
Max. link distance multimode fiber
at data rate 9.9532 to 10.3125 Gbit/s
50/125 µm MMF 400 2 m - 66 m
50/125 µm MMF 500 2 m - 82 m
50/125 µm MM fiber OM3 2 m - 300 m

62.5/125 µm MMF 160 2 m - 26 m


62.5/125 µm MMF 200 2 m - 32 m
Bit error ratio < 10-12
Max. module delay < 50 ns

408 Module and System Specification


Chapter 6 Pluggable Transceivers

XFP/10G/850I/MM/LC (HW Rev. 2.01)

The XFP/10G/850I/MM/LC (HW Rev. 2.01) is an MSA-compliant pluggable


transceiver for 10 Gbit/s data rates and bidirectional communication over
multimode fiber. It is operating at a wavelength of 850 nm and it provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.

Table 725: Technical Data


Equipment type XFP-G
First release 11.1
Module type XFP
Weight 50 g (0.11 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 5,707,437 h
Optical connector type Duplex LC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Transmitter fiber type MM 62.5 µm


Receiver fiber type MM 62.5 µm
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s
Protocols 10 GbE LAN PHY, 10 GbE WAN PHY,
10G FC
Transmitter output power range -8 dBm ... -1 dBm
Transmitter wavelength range 840 nm ... 860 nm
Min. extinction ratio 3 dB
Receiver wavelength range 840 nm ... 860 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -9.9 dBm ... -1 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -11 dBm ... 2 dBm
Max. link distance multimode fiber
at data rate 9.9532 to 10.3125 Gbit/s
50/125 µm MMF 400 2 m - 66 m
50/125 µm MMF 500 2 m - 82 m
50/125 µm MM fiber OM3 2 m - 300 m

62.5/125 µm MMF 160 2 m - 26 m


62.5/125 µm MMF 200 2 m - 32 m
Bit error ratio < 10-12
Max. module delay < 3 ns

Module and System Specification 409


XFP/11G/1310S/SM/LC

XFP/11G/1310S/SM/LC
The XFP/11G/1310S/SM/LC is an MSA-compliant pluggable transceiver for 
10 Gbit/s and 11 Gbit/s data rates and bidirectional communication over
single-mode fiber. It is operating at a wavelength of 1310 nm and it provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. It is intended for use in FSP 3000R7 modules
with XFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with XFP types approved by ADVA
Optical Networking only.

Table 726: Technical Data


Equipment type XFP-G
First release 7.0
Module type XFP
Weight 50 g (0.11 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 4,484,299 h
Optical connector type Duplex LC

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s, 10.6642 Gbit/s,
10.709 Gbit/s, 11.0491 Gbit/s,
11.0957 Gbit/s, 11.317 Gbit/s
Protocols STM-64/OC-192, 10 GbE LAN PHY,
10 GbE WAN PHY, 10G FC, OTU2,
OTU2e
Transmitter output power range -6 dBm ... -1 dBm
Transmitter wavelength range 1290 nm ... 1330 nm
Min. extinction ratio 6 dB
Nominal receiver wavelength range 1260 nm ... 1360 nm
Receiver dynamic range -13 dBm ... -1 dBm
at 1260 nm ... 1360 nm
Receiver dynamic range -11 dBm ... -1 dBm
at 1530 nm ... 1565 nm
Max. receiver reflectance 14 dB
OPR/OPT accuracy +/- 3 dB
OPR measurement range -13 dBm ... 2 dBm
Max. link distance 10 km
with SMF-28 single-mode fiber
Max. power penalty at dispersion  2 dB
(depending on link distance)
Bit error ratio < 10-12
Max. module delay < 3 ns

410 Module and System Specification


Chapter 6 Pluggable Transceivers

XFP/11G/1550L/SM/LC
The XFP/11G/1550L/SM/LC is an MSA-compliant pluggable transceiver for 
10 Gbit/s data rates and bidirectional communication over single-mode fiber. It
is operating at a wavelength of 1550 nm and it provides digital diagnostic
monitoring of operating parameters such as optical input power, temperature or
laser bias. It is intended for use in FSP 3000R7 modules with XFP interface
cages. Proper functionality and valid certification of transponder modules can
be guaranteed with XFP types approved by ADVA Optical Networking only.

Table 727: Technical Data


Equipment type XFP-G
First release 7.1
Module type XFP
Weight 50 g (0.11 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 4,848,849 h
Optical connector type Duplex LC
Transmitter fiber type SM
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Receiver fiber type SM


Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s, 10.6642 Gbit/s,
10.709 Gbit/s, 11.0491 Gbit/s,
11.0957 Gbit/s, 11.317 Gbit/s
Protocols STM-64/OC-192, 10 GbE LAN PHY, 
10 GbE WAN PHY, 10G FC, OTU2
Transmitter output power range -1 dBm ... +2 dBm
Transmitter wavelength range 1530 nm ... 1565 nm
Min. extinction ratio 8 dB
Nominal receiver wavelength range 1530 nm ... 1565 nm
Receiver dynamic range  -11 dBm ... -1 dBm
at 1530 nm ... 1565 nm
Receiver dynamic range  -9 dBm ... -1 dBm
at 1260 nm ... 1360 nm
Max. receiver reflectance 27 dB
OPR measurement range -11 dBm ... 2 dBm
OPR/OPT accuracy +/- 3 dB
Max. power penalty at dispersion  2 dB
(depending on link distance)
Bit error ratio < 10-12
Max. module delay < 50 ns

Module and System Specification 411


XFP/8G/1310S/SM/LC

XFP/8G/1310S/SM/LC
The XFP/8G/1310S/SM/LC is an MSA-compliant pluggable transceiver for data
rates of 4.25 Gbit/s and 8.5 Gbit/s and bidirectional communication over
single-mode fiber. It is operating at a wavelength of 1310 nm and it provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. It is intended for use in FSP 3000R7 modules
with XFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with XFP types approved by ADVA
Optical Networking only.

Table 728: Technical Data


Equipment type XFP-G
First release 9.2
Module type XFP
Weight 50 g (0.11 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 4,154,452 h
Optical connector type Duplex LC

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmitter fiber type SM
Receiver fiber type SM
Data rates 4.25 Gbit/s, 8.5 Gbit/s
Protocols 4G FC, 8G FC
Transmitter output power range -6 dBm ... -1 dBm
Transmitter wavelength range 1290 nm ... 1330 nm
Min. extinction ratio 4 dB
Nominal receiver wavelength range 1260 nm ... 1360 nm
Receiver dynamic range  -10 dBm ... 0.5 dBm
at 1260 nm ... 1360 nm
Receiver dynamic range  -8 dBm ... 0.5 dBm
at 1530 nm ... 1565 nm
Max. receiver reflectance 14 dB
OPR/OPT accuracy +/- 3 dB
OPR measurement range -10 dBm ... 3.5 dBm
Max. link distance 10 km
with SMF-28 single-mode fiber
Bit error ratio < 10-12
Max. module delay < 3 ns

412 Module and System Specification


Chapter 6 Pluggable Transceivers

XFP/8G/850I/MM/LC
The XFP/8G/850I/MM/LC is an MSA-compliant pluggable transceiver for data
rates of 4.25 Gbit/s and 8.5 Gbit/s and bidirectional communication over
multimode fiber. It is operating at a wavelength of 850 nm and it provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias. It is intended for use in FSP 3000R7 modules with
XFP interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with XFP types approved by ADVA Optical
Networking only.

Table 729: Technical Data


Equipment type XFP-G
First release 9.2
Module type XFP
Weight 50 g (0.11 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 1,854,666 h
Optical connector type Duplex LC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Transmitter fiber type MM 62.5 µm


Receiver fiber type MM 62.5 µm
Data rates 4.25 Gbit/s, 8.5 Gbit/s
Protocols 4G FC, 8G FC
Transmitter output power range -8 dBm ... -1 dBm
Transmitter wavelength range 840 nm ... 860 nm
Min. extinction ratio 3 dB
Receiver wavelength range 840 nm ... 860 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -11 dBm ... -1 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -11 dBm ... 2 dBm
Max. link distance multimode fiber
50/125 μm MMF 400 2 m - 66 m
50/125 μm MMF 500 2 m - 82 m
50/125 μm MM fiber OM3 2 m - 300 m

62.5/125 μm MMF 160 2 m - 26 m


62.5/125 μm MMF 200 2 m - 32 m
Bit error ratio < 10-12
Max. module delay < 3 ns

Module and System Specification 413


SFP+/16GFC/1310S/SM/LC

SFP+/16GFC/1310S/SM/LC
The SFP+/16GFC/1310S/SM/LC is an MSA-compliant pluggable transceiver for
4.25 Gbit/s, 8.5 Gbit/s and 14.025 Gbit/s data rates and bidirectional
communication over single-mode fiber. It is operating at a wavelength of
1310 nm and it provides digital diagnostic monitoring of operating parameters
such as optical input power, temperature or laser bias. It is intended for use in
FSP 3000R7 modules with SFP+ interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP+ types
approved by ADVA Optical Networking only.

Table 730: Technical Data


Equipment type SFP-G
First release 11.2
Module type SFP+
Weight 20 g (0.044 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 4,800,000 h
Optical connector type Duplex LC

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmitter fiber type 9/125 µm SM
Receiver fiber type 9/125 µm SM
Data rates 4.25 Gbit/s, 8.5 Gbit/s, 
14.025 Gbit/s
Transmitter output power range -5 dBm ... +2 dBm
Transmitter wavelength range 1295 nm ... 1325 nm
Min. extinction ratio 3.5 dB
Receiver wavelength range 1260 nm ... 1610 nm
Max. average receiver power 2 dBm
Receiver dynamic range -12 dBm ... +2 dBm
Max. receiver reflectance 12 dB
Max. link distance 10 km
OPR/OPT accuracy +/- 3 dB
OPR measurement range -15 dBm ... +5 dBm
Bit error ratio <10-12
Max. module delay < 3 ns

414 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP+/16GFC/850I/MM/LC
The SFP+/16GFC/850I/MM/LC is an MSA-compliant pluggable transceiver for
4.25 Gbit/s, 8.5 Gbit/s and 14.025 Gbit/s data rates and bidirectional
communication over multimode fiber. It is operating at a wavelength of 850 nm
and it provides digital diagnostic monitoring of operating parameters such as
optical input power, temperature or laser bias. It is intended for use in FSP
3000R7 modules with SFP+ interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP+ types
approved by ADVA Optical Networking only.

Table 731: Technical Data


Equipment type SFP-G
First release 11.2
Module type SFP+
Weight 20 g (0.044 lbs)
Environmental conditions Telcordia SR-3580 level 3
(NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree
IEC 60529 2 environment and indoor
controlled office environments
only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

MTBF at 25°C ambient temperature 15,479,876 h


Optical connector type Duplex LC
Transmitter fiber type MM 50 µm
Receiver fiber type MM 50 µm
Data rates 4.25 Gbit/s, 8.5 Gbit/s,
14.025 Gbit/s
Transmitter output power range -8 dBm ... 0 dBm
Transmitter wavelength range 840 nm ... 860 nm
Min. extinction ratio 4 dB
Receiver wavelength range 840 nm ... 860 nm
Max. average receiver power 0 dBm
Receiver dynamic range -10 dBm ... -1 dBm
Max. receiver reflectance 12 dB
Max. link distance 150 m at 4.25 Gbit/s
50/125 µm MMF 50 m at 8.5 Gbit/s
35 m at 14.025 Gbit/s
50/125 µm MM fiber OM3 380 m at 4.25 Gbit/s
150 m at 8.5 Gbit/s
100 m at 14.025 Gbit/s
OPR/OPT accuracy +/- 3 dB
OPR measurement range -13 dBm ... +2 dBm
Bit error ratio <10-12
Max. module delay < 3 ns

Module and System Specification 415


SFP+CDR/10GU/1550L/SM/LC

SFP+CDR/10GU/1550L/SM/LC
The SFP+CDR/10GU/1550L/SM/LC is an MSA-compliant pluggable transceiver
for 8.5 Gbit/s, 9.9533 Gbit/s, 10.0 Gbit/s and 10.3125 Gbit/s data rates. It is
used for bidirectional communication over single-mode fiber. This transceiver
supports clock and data recovery.
The SFP+CDR/10GU/1550L/SM/LC is operating at a wavelength of 1550 nm
and provides digital diagnostic monitoring of operating parameters such as opti-
cal input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages.
Proper functionality and valid certification of transponder modules can be guar-
anteed with SFP+ types approved by ADVA Optical Networking only.

Table 732: Technical Data


Equipment type SFP-CDR-G
First release 11.2
Module type SFP+
Weight 20 g (0.044 lbs)
Environmental conditions Telcordia SR-3580 level 3
(NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
IEC 60529 2 environment and indoor
controlled office environments
only.
MTBF at 25°C ambient temperature 6,711,409 h
Optical connector type Duplex LC
Transmitter fiber type SM 9/125 µm
Receiver fiber type SM 9/125 µm
Data rates 8.5 Gbit/s, 9.9533 Gbit/s, 
10.0 Gbit/s, 10.3125 Gbit/s
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelength range 1530 nm ... 1565 nm
Min. extinction ratio 3 dB
Receiver wavelength range 1530 nm ... 1565 nm
Receiver dynamic range -16 dBm ... -1 dBm
Max. receiver reflectance 27 dB
OPR/OPT accuracy +/- 3 dB
OPR measurement range -18 dBm ... +1 dBm
Max. power penalty at dispersion 3 dB
Bit error ratio <10-12
Max. module delay 5 ns

416 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP+CDR/10GU/850I/MM/LC
The SFP+CDR/10GU/850I/MM/LC is an MSA-compliant pluggable transceiver
for 8.5 Gbit/s and 10.3125 Gbit/s data rates and bidirectional communication
over multimode fiber. This transceiver supports clock and data recovery.
The SFP+CDR/10GU/850I/MM/LC is operating at a wavelength of 850 nm and
provides digital diagnostic monitoring of operating parameters such as optical
input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages.
Proper functionality and valid certification of transponder modules can be guar-
anteed with SFP+ types approved by ADVA Optical Networking only.

Table 733: Technical Data


Equipment type SFP-CDR-G
First release 11.2
Module type SFP+
Weight 20 g (0.044 lbs)
Environmental conditions Telcordia SR-3580 level 3
(NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree
IEC 60529 2 environment and indoor
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

controlled office environments


only.
MTBF at 25°C ambient temperature 13,000,000 h
Optical connector type Duplex LC
Transmitter fiber type MM 50 µm
Receiver fiber type MM 50 µm
Data rates 8.5 Gbit/s, 10.3125 Gbit/s,
Transmitter output power range -8 dBm ... 0 dBm
Transmitter wavelength range 840 nm ... 860 nm
Receiver wavelength range 770 nm ... 860 nm
Max. average receiver power 0 dBm
Receiver dynamic range -10 dBm ... -1 dBm
Max. receiver reflectance 12 dB
OPR/OPT accuracy +/- 3 dB
OPR measurement range -14 dBm ... +2 dBm
Max. power penalty at dispersion 4.3 dB
Max. link distance
50/125 µm MMF, 50 m
OM2 / MMF400 50 m
50/125 µm MM fiber OM3 150 m
Bit error ratio <10-12
Max. module delay 5 ns

Module and System Specification 417


SFP+CDR/11GU/1310S/SM/LC

SFP+CDR/11GU/1310S/SM/LC
The SFP+CDR/11GU/1310S/SM/LC is an MSA-compliant pluggable trans-
ceiver for 8.5 Gbit/s, 9.9533 Gbit/s, 10 Gbit/s, 10.3125 Gbit/s, 10.518 Gbit/s,
10.709 Gbit/s, 11.0491 Gbit/s, 11.0957 Gbit/s and 11.3176 Gbit/s data rates. It
is used for bidirectional communication over single-mode fiber. This transceiver
supports clock and data recovery.
The SFP+CDR/11GU/1310S/SM/LC is operating at a wavelength of 1310 nm
and provides digital diagnostic monitoring of operating parameters such as opti-
cal input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages.
Proper functionality and valid certification of transponder modules can be guar-
anteed with SFP+ types approved by ADVA Optical Networking only.

Table 734: Technical Data


Equipment type SFP-CDR-G
First release 11.2
Module type SFP+
Weight 20 g (0.044 lbs)
Environmental conditions Telcordia SR-3580 level 3
(NEBS),
ETSI EN 300 019-1-3 Class 3.1

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Degree of protection according to  IP20. Use in a pollution degree
IEC 60529 2 environment and indoor
controlled office environments
only.
MTBF at 25°C ambient temperature 3,060,000 h
Optical connector type Duplex LC
Transmitter fiber type SM 9/125 µm
Receiver fiber type SM 9/125 µm
Data rates 8.5 Gbit/s, 9.9533 Gbit/s, 
10 Gbit/s, 10.3125 Gbit/s,
10.518 Gbit/s, 10.709 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s,
11.3176 Gbit/s
Transmitter output power range -6 dBm ... -1 dBm
Transmitter wavelength range 1260 nm ... 1355 nm
Min. extinction ratio 6 dB
Receiver wavelength range 1260 nm ... 1600 nm
Max. average receiver power 0.5 dBm
Receiver dynamic range -11 dBm ... +0.5 dBm
Max. receiver reflectance 14 dB
OPR/OPT accuracy +/- 3 dB
OPR measurement range -14 dBm ... +2 dBm

418 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 734: Technical Data


Max. power penalty 1 dB at 9.9533 Gbit/s, 
10.709 Gbit/s, 11.0491 Gbit/s,
11.0957 Gbit/s

3.2 dB at 8.5 Gbit/s, 10 Gbit/s,


11.3176 Gbit/s, 10.3125 Gbit/s
Bit error ratio <10-12
Max. module delay 5 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 419


SFP+CDR/11GU/CxxxxL/SM/LC

SFP+CDR/11GU/CxxxxL/SM/LC
The SFP+CDR/11GU/CxxxxL/SM/LC is an MSA-compliant pluggable
transceiver for 11 Gbit/s data rates and bidirectional communication over
single-mode fiber. This transceiver supports clock and data recovery.
The SFP+CDR/11GU/CxxxxL/SM/LC is operating at eight CWDM wavelengths
with long reach according to ITU-T G.694.2. It provides digital diagnostic
monitoring of operating parameters such as optical input power, temperature or
laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages.
Proper functionality and valid certification of transponder modules can be
guaranteed with SFP+ types approved by ADVA Optical Networking only.

Table 735: Technical Data


Equipment type SFP-CDR-C
First release 12.3
Module type SFP+
Weight 20 g (0.04 lbs)
Maximum power consumption 1.5 W
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
IEC 60529 environment and indoor controlled office
environments only.
MTBF at 25°C ambient 6,711,409 h
temperature
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 8.5 Gbit/s, 9.9532 Gbit/s, 10.0 Gbit/s,
10.3125 Gbit/s, 10.518 Gbit/s,
10.709 Gbit/s, 11.0491 Gbit/s,
11.0957 Gbit/s, 11.3176 Gbit/s
Protocols 8G FC, STM-64/OC-192, 10 GbE WAN
PHY, 10G IB, 10G FC, OTU2, OTU1e,
OTU2e, OTU2f
Transmitter output power range -4.7 dBm ... +4 dBm
Transmitter wavelength range 1471 nm, 1491 nm, 1511 nm, 1531 nm
1551 nm, 1571 nm, 1591 nm, 1611 nm
Center wavelength stability +/- 6.5 nm
Min. extinction ratio 3.0 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1450 nm ... 1620 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -16.0 dBm ... -1.0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -19 dBm to +1 dBm

420 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 735: Technical Data (Continued)


Max. power penalty at dispersion 3 dB at max. dispersion load
(regarding receiver sensitivity) 3 dB at min. dispersion load
Maximum dispersion load 520ps/nm for 1471 nm
560ps/nm for 1491 nm
600ps/nm for 1511 nm
640ps/nm for 1531 nm
680ps/nm for 1551 nm
720ps/nm for 1571 nm
760ps/nm for 1591 nm
800ps/nm for 1611 nm
Minimum dispersion load -240ps/nm for 1471 nm
-280ps/nm for 1491 nm
-300ps/nm for 1511 nm
-320ps/nm for 1531 nm
-340ps/nm for 1551 nm
-360ps/nm for 1571 nm
-380ps/nm for 1591 nm
-400ps/nm for 1611 nm
Bit error ratio < 10-12
Max. module delay 3 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 421


SFP+CDR/11GU/CxxxxS/SM/LC

SFP+CDR/11GU/CxxxxS/SM/LC
The SFP+CDR/11GU/CxxxxS/SM/LC is an MSA-compliant pluggable
transceiver for 11 Gbit/s data rates and bidirectional communication over
single-mode fiber. This transceiver supports clock and data recovery.
The SFP+CDR/11GU/CxxxxS/SM/LC operates at four CWDM wavelengths with
standard reach according to ITU-T G.694.2. It provides digital diagnostic
monitoring of operating parameters such as optical input power, temperature or
laser bias. This SFP+ transceiver is intended to be used to connect to
40GBASE-LR4 using J/SM/4CS-#C1270-#C1330/LC breakout cable.
The SFP+CDR/11GU/CxxxxS/SM/LC is intended for use in FSP 3000R7
modules with SFP+ interface cages. Proper functionality and valid certification
of transponder modules can be guaranteed with SFP+ types approved by ADVA
Optical Networking only.

Table 736: Technical Data


Equipment type SFP-CDR-C
First release 12.3
Module type SFP+
Weight 20 g (0.04 lbs)
Maximum power consumption 1.5 W
Environmental conditions Telcordia SR-3580 level 3 (NEBS),

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled office
environments only.
MTBF at 25°C ambient 2,518,892 h
temperature
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.0 Gbit/s, 10.3125
Gbit/s, 10.5187 Gbit/s, 10.709 Gbit/s,
10.754 Gbit/s, 11.0491 Gbit/s, 11.0957
Gbit/s, 11.3176 Gbit/s
Protocols STM-64/OC-192, 10 GbE WAN PHY,
10G IB, 10 GbE LAN PHY, 10G FC,
OTU2, OTU2V, OTU1e, OTU2e, OTU2f
Transmitter output power range -5 dBm ... 0 dBm
Transmitter wavelength range 1271 nm, 1291 nm, 1311 nm, 1331 nm
Center wavelength stability +/- 6.5 nm
Min. extinction ratio 3.5 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1250 nm ... 1350 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -13.0 dBm ... 0 dBm
OPR/OPT accuracy +/- 3 dB

422 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 736: Technical Data (Continued)


OPR measurement range -18 dBm ... +2 dBm
Max. power penalty at dispersion 2 dB at max. dispersion load
(regarding receiver sensitivity) 2 dB at min. dispersion load
Maximum dispersion load 40ps/nm for 1271 nm
50ps/nm for 1291 nm
50ps/nm for 1311 nm
60ps/nm for 1331 nm
Minimum dispersion load -60ps/nm for 1271 nm
-55ps/nm for 1291 nm
-50ps/nm for 1311 nm
-50ps/nm for 1331 nm
Bit error ratio < 10-12
Max. module delay 3 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 423


SFP+/10G/1310S/SM/LC

SFP+/10G/1310S/SM/LC
The SFP+/10G/1310S/SM/LC is an MSA-compliant pluggable transceiver
supporting up to 10 Gbit/s data rates and bidirectional communication over
single-mode fiber. It is operating at a wavelength of 1310 nm and it provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. It is intended for use in FSP 3000R7 modules
with SFP+ interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP+ types approved by ADVA
Optical Networking only.

Table 737: Technical Data


Equipment type SFP-G
First release 9.3
Module type SFP+
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 1,621,140 h
Optical connector type Duplex LC

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmitter fiber type 9/125 µm SM
Receiver fiber type 9/125 µm SM
Data rates 5 Gbit/s, 8.5 Gbit/s, 9.953 Gbit/s, 
10 Gbit/s, 10.3125 Gbit/s, 
10.51875 Gbit/s
Transmitter output power range -8 dBm ... -0.5 dBm
Transmitter wavelength range 1260 nm ... 1355 nm
Min. extinction ratio 3.5 dB
Receiver wavelength range 1260 nm ... 1355 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -14 dBm ... 0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -17 dBm ... 3 dBm
Max. power penalty at dispersion 3.2 dB
Max. link distance 10 km
Bit error ratio < 10-12
Max. module delay 3 ns

424 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP+/10G/850I/MM/LC
The SFP+/10G/850I/MM/LC is an MSA-compliant pluggable transceiver
supporting up to 10 Gbit/s data rates and bidirectional communication over
multimode fiber. It is operating at a wavelength of 850 nm and it provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias. It is intended for use in FSP 3000R7 modules with
SFP+ interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with SFP+ types approved by ADVA Optical
Networking only.

Table 738: Technical Data


Equipment type SFP-G
First release 9.3
Module type SFP+
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 75,769,049 h
Optical connector type Duplex LC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Transmitter fiber type MM 62.5 µm


Receiver fiber type MM 62.5 µm
MM 50 µm
Data rates 5 Gbit/s, 8.5 Gbit/s, 10 Gbit/s,
10.3125 Gbit/s, 10.51875 Gbit/s
Transmitter output power range -8 dBm ... -1 dBm
Transmitter wavelength range 830 nm ... 860 nm
Min. extinction ratio 4 dB
Receiver wavelength range 840 nm ... 860 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -11 dBm ... -1 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -18 dBm ... 2 dBm
Max. power penalty at dispersion 3.9 dB
Max. link distance, 50 μm MM fiber dependent on customer interface 
50 m for standard fiber 
200 m for OM3 fiber
Max. link distance, 62.5 μm MM fiber 20 m
Bit error ratio < 10-12
Max. module delay 3 ns

Module and System Specification 425


SFP+/11GU/#19xxxL50/SM/LC

SFP+/11GU/#19xxxL50/SM/LC
The SFP+/11GU/#19xxxL50/SM/LC is an MSA-compliant pluggable transceiver
for 11 Gbit/s data rates and bidirectional communication over single-mode fiber.
It operates at 50GHz DWDM wavelengths according to ITU-T G.694.1 and it
provides digital diagnostic monitoring of operating parameters such as optical
input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages.
Proper functionality and valid certification of transponder modules can be
guaranteed with SFP types approved by ADVA Optical Networking only.

Table 739: Technical Data


Equipment type SFP-D
First release 12.3
Module type SFP+
Weight 20 g (0.04 lbs)
Maximum power consumption 1.5W
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 4,329,004 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 8.5 Gbit/s, 9.9532 Gbit/s, 10.0 Gbit/s,
10.3125 Gbit/s, 10.518 Gbit/s,
10.709 Gbit/s, 10.7595 Gbit/s
10.9747 Gbit/s, 11.0491 Gbit/s,
11.0957 Gbit/s, 11.3176 Gbit/s
Protocols 8G FC, STM-64/OC-192,
10 GbE WAN PHY, 10G IB,
10 GbE LAN PHY, 10G FC, OTU2,
10G IB, OTU2V, OTU1e, OTU2e,
OTU2f
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelength range 96 channels, 50 GHz spacing in C
band acc. to ITU-T G.694.1
41 channels, 100 GHz spacing in C
band acc. to ITU-T G.694.1
Wavelength stability (operating) +/- 25 pm
Min. extinction ratio 8 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1270 nm ... 1600 nm
Max. receiver reflectance 27 dB

426 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 739: Technical Data (Continued)


Receiver dynamic range for  -16.0 dBm ... -1.0 dBm
BER < 10-5
Receiver dynamic range for  -18.0 dBm ... -1.0 dBm
BER > 10-5
OPR/OPT measurement accuracy +/- 3 dB
OPR measurement range 20 dBm ... 0 dBm
Dispersion load range -700 ps/nm ... +700 ps/nm
Optimum dispersion load 0 ps/nm
Dispersion load range with 1 dB -500 ps/nm ... -300 ps/nm and 
OSNR penalty +300 ps/nm ...+500 ps/nm
Dispersion load range with 2 dB -700 ps/nm ... -500 ps/nm and 
OSNR penalty +500 ps/nm ... +700 ps/nm
Maximum DGD 30ps
OSNR penalty at 10 ps PMD for BER 1 dB (outage probability 4x10-5)
> 10-5
OSNR penalty at 7 ps PMD for BER 1 dB (outage probability 4x10-5)
> 10-12
OSNR penalty at 11.1 Gbit/s data 1 dB
rate
OSNR penalty at 11.3 Gbit/s data 2 dB
rate
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Bit error ratio < 10-12 at 25 dB OSNR (0.1 nm)


< 10-9 at 23 dB OSNR (0.1 nm)
< 10-5 at 19 dB OSNR (0.1 nm)
< 10-4 at 17 dB OSNR (0.1 nm)
< 10-3 at 15 dB OSNR (0.1 nm)
OSNR Penalty at -18dBm optical 1dB
input power
Max. module delay 3 ns

Module and System Specification 427


SFP+/11GU/CxxxxL/SM/LC

SFP+/11GU/CxxxxL/SM/LC
The SFP+/11GU/CxxxxL/SM/LC is an MSA-compliant pluggable transceiver for 
11 Gbit/s data rates and bidirectional communication over single-mode fiber. It
is operating at CWDM wavelengths according to ITU-T G.694.2 and it provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages.
Proper functionality and valid certification of transponder modules can be
guaranteed with SFP+ types approved by ADVA Optical Networking only.

Table 740: Technical Data


Equipment type SFP-C
First release 12.1
Module type SFP+
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled office
environments only.
MTBF at 25°C ambient 5,649,717 h
temperature

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 8.5 Gbit/s, 9.9532 Gbit/s, 10.0 Gbit/s,
10.3125 Gbit/s, 10.5187 Gbit/s,
10.709 Gbit/s, 10.754 Gbit/s,
10.7595 Gbit/s, 10.9747 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s,
11.3176 Gbit/s
Protocols 8G FC, STM-64/OC-192, 10G IB,
10 GbE, 10G FC, OTU2, OTU2V ,
OTU1e, OTU2e
Transmitter output power range -4 dBm ... +4 dBm
Transmitter wavelength range 1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm, 1611 nm
Min. extinction ratio 4.5 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1450 nm ... 1620 nm
Max. receiver reflectance 26 dB
Receiver dynamic range -16.0 dBm ... -1.0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -18 dBm ... +2 dBm
Max. power penalty at dispersion 3 dB at max. dispersion load
(regarding receiver sensitivity) 3 dB at min. dispersion load

428 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 740: Technical Data (Continued)


Maximum dispersion load 520ps/nm for 1471 nm
560ps/nm for 1491 nm
600ps/nm for 1511 nm
640ps/nm for 1531 nm
680ps/nm for 1551 nm
720ps/nm for 1571 nm
760ps/nm for 1591 nm
800ps/nm for 1611 nm
Minimum dispersion load -260ps/nm for 1471 nm
-280ps/nm for 1491 nm
-300ps/nm for 1511 nm
-320ps/nm for 1531 nm
-340ps/nm for 1551 nm
-360ps/nm for 1571 nm
-380ps/nm for 1591 nm
-400ps/nm for 1611 nm
Bit error ratio < 10-12
Max. module delay 3 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 429


SFP+/11GU/1310S/SM/LC

SFP+/11GU/1310S/SM/LC
The SFP+/11GU/1310S/SM/LC is an MSA-compliant pluggable transceiver
supporting up to 11 Gbit/s data rates and bidirectional communication over
single-mode fiber. It is operating at a wavelength of 1310 nm and it provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. It is intended for use in FSP 3000R7 modules
with SFP+ interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP+ types approved by ADVA
Optical Networking only.

Table 741: Technical Data


Equipment type SFP-G
First release 12.1
Module type SFP+
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 682,198 h
Optical connector type Duplex LC

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmitter fiber type 9/125 µm SM
Receiver fiber type 9/125 µm SM
Data rates 5.0 Gbit/s1, 8.5 Gbit/s, 9.9533 Gbit/s,
10.0 Gbit/s, 10.3125 Gbit/s, 10.51875
Gbit/s, 10.709 Gbit/s, 10.7595 Gbit/s,
10.9747 Gbit/s, 11.0491 Gbit/s,
11.0957 Gbit/s, 11.3176 Gbit/s
Protocols 5G IB, 8G FC, STM-64/OC-192,
10G IB, 10 GbE, 10G FC, OTU2,
OTU2V, OTU1e, OTU2e
Transmitter output power range -8 dBm ... -1.0 dBm
Transmitter wavelength range 1290 nm ... 1330 nm
Min. extinction ratio 6.0 dB
Receiver wavelength range 1260 nm ... 1360 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -13.0 dBm ... -1.0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -13 dBm ... 2 dBm
Max. power penalty at dispersion 3.2 dB
Max. link distance 10 km
Bit error ratio < 10-12
Max. module delay 3 ns
1. 5.0 Gbit/s = 5G IB for HW rev. 2.01 or newer

430 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP+/11GU/850I/MM/LC
The SFP+/11GU/850I/MM/LC is an MSA-compliant pluggable transceiver
supporting up to 11 Gbit/s data rates and bidirectional communication over
multimode fiber. It is operating at a wavelength of 850 nm and it provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias. It is intended for use in FSP 3000R7 modules with
SFP+ interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with SFP+ types approved by ADVA Optical
Networking only.

Table 742: Technical Data


Equipment type SFP-G
First release 12.1
Module type SFP+
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 76,923,077 h
Optical connector type Duplex LC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Transmitter fiber type MM 62.5 µm


Receiver fiber type MM 62.5 µm
MM 50 µm
Data rates 5.0 Gbit/s1, 8.5 Gbit/s, 9.9533
Gbit/s, 10.0 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s, 10.709 Gbit/s,
10.754 Gbit/s, 10.7595 Gbit/s,
10.9747 Gbit/s, 11.0491 Gbit/s,
11.0957 Gbit/s, 11.3176 Gbit/s
Protocols 5G IB, 8G FC, STM-64/OC-192,
10G IB, 10 GbE, 10G FC, OTU2,
OTU2V, OTU1e, OTU2e
Transmitter output power range -8 dBm ... -1 dBm
Transmitter wavelength range 840 nm ... 860 nm
Min. extinction ratio 4 dB
Receiver wavelength range 840 nm ... 860 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -11 dBm ... -1 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -14 dBm ... 2 dBm
Max. power penalty at dispersion 3.9 dB
Max. link distance, 50 μm MM fiber dependent on customer interface 
50 m for standard fiber 
200 m for OM3 fiber

Module and System Specification 431


SFP+/11GU/850I/MM/LC

Table 742: Technical Data (Continued)


Max. link distance, 62.5 μm MM fiber 20 m
Bit error ratio < 10-12
Max. module delay 3 ns
1. 5.0 Gbit/s = 5G IB for HW rev. 2.01 or newer

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

432 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP+/8GU/1310S/SM/LC
The SFP+/8GU/1310S/SM/LC is an MSA-compliant pluggable transceiver for
data rates of 2.125 Gbit/s, 4.25 Gbit/s and 8.5 Gbit/s and bidirectional
communication over single-mode fiber. It is operating at a wavelength of
1310 nm and it provides digital diagnostic monitoring of operating parameters
such as optical input power, temperature or laser bias. It is intended for use in
FSP 3000R7 modules with SFP+ interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP+ types
approved by ADVA Optical Networking only.

Table 743: Technical Data


Equipment type SFP-G
First release 9.3
Module type SFP+
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 3,200,000 h
Optical connector type Duplex LC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Transmitter fiber type SM 9/125 µm


Receiver fiber type SM 9/125 µm
Data rates 2.125 Gbit/s, 4.250 Gbit/s, 8.5 Gbit/s
Transmitter output power range -8.5 dBm ... 0.5 dBm at 8.5 Gbit/s
-8.5 dBm ... -3 dBm at 2.25 Gbit/s and
4.25 Gbit/s
Transmitter wavelength range 1285 nm ... 1345 nm
Min. extinction ratio 4 dB
Receiver wavelength range 1260 nm ... 1360 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -13 dBm ... 0.5 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -16 dBm ... 3.5 dBm
Max. power penalty at dispersion 3.2 dB
Max. link distance 10 km at 2.125 Gbit/s
10 km at 4.250 Gbit/s
10 km at 8.5 Gbit/s
Bit error ratio < 10-12
Max. module delay 3 ns

Module and System Specification 433


SFP+/8GU/850I/MM/LC

SFP+/8GU/850I/MM/LC
The SFP+/8GU/850I/MM/LC is an MSA-compliant pluggable transceiver for
data rates of 2.125 Gbit/s, 4.25 Gbit/s and 8.5 Gbit/s and bidirectional
communication over multimode fiber. It is operating at a wavelength of 850 nm
and it provides digital diagnostic monitoring of operating parameters such as
optical input power, temperature or laser bias. It is intended for use in FSP
3000R7 modules with SFP+ interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP+ types
approved by ADVA Optical Networking only.

Table 744: Technical Data


Equipment type SFP-G
First release 9.3
Module type SFP+
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 5,948,000 h
Optical connector type Duplex LC

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmitter fiber type MM 62.5 µm
Receiver fiber type MM 62.5 µm
MM 50 µm
Data rates 2.125 Gbit/s, 4.250 Gbit/s, 8.5 Gbit/s
Transmitter output power range -9 dBm ... -2 dBm
Transmitter wavelength range 830 nm ... 860 nm
Min. extinction ratio 4 dB
Receiver wavelength range 840 nm ... 860 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -10 dBm ... 1 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -13 dBm ... 4 dBm
Max. power penalty at dispersion 4.2 dB
Max. link distance, 50 μm MM fiber dependent on customer interface
for standard fiber:
300 m at 2.125 Gbit/s
150 m at 4.250 Gbit/s
50 m at 8.5 Gbit/s

for OM3 fiber:


500 m at 2.125 Gbit/s
380 m at 4.250 Gbit/s
150 m at 8.5 Gbit/s
Bit error ratio < 10-12
Max. module delay 3 ns

434 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP/4GU/Dxxxx.xxV/SM/LC#Dxx
The SFP/4GU/Dxxxx.xxV/SM/LC#Dxx is an MSA-compliant pluggable
transceiver for bidirectional communication over single-mode fiber. It is
operating at DWDM wavelengths according to ITU-T G.694.1. It provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias. It is intended for use in FSP 3000R7 modules with
SFP interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with SFP types approved by ADVA Optical
Networking only.

Table 745: Technical Data


Equipment type SFP-D
First release 8.1
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled office
environments only.
MTBF at 25°C ambient 4,830,918 h
temperature
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Optical connector type Duplex LC


Transmitter fiber type SM G.652
Receiver fiber type SM G.652
Data rates 1.0625 Gbit/s, 2.125 Gbit/s, 4.250 Gbit/s
Transmitter output power range +2 dBm ... +5 dBm
Transmitter wavelengths 82 channels, 100 GHz spacing in C and L
depending on respective SFP band acc. ITU-T G.694.1
type
Wavelength stability (operating) +/- 100 pm
Min. extinction ratio 5 dB
Min. side mode suppression ratio 30 dB
Receiver wavelength range 1260 nm ... 1610 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -23 ... -9 dBm at 30 dB OSNR at 0.1 nm
(including dispersion penalties) -21 ... -9 dBm at 25 dB OSNR at 0.1 nm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -23 dBm ... -6 dBm
Min. dispersion load 0 ps/nm
Max. dispersion load 1400 ps/nm
OSNR penalty 0 dB
Receiver power penalty at 1 dB at 1100 ps/nm ... 1400 ps/nm
dispersion
OSNR PMD penalty 1 dB at 20 ps (outage probability 4x10-5)
Bit error ratio < 10-12

Module and System Specification 435


SFP/4GU/CxxxxV/SM/LC (HW Rev. 2.01)

SFP/4GU/CxxxxV/SM/LC (HW Rev. 2.01)


The SFP/4GU/CxxxxV/SM/LC (HW Rev. 2.01) is an MSA-compliant pluggable
transceiver for bidirectional communication over single-mode fiber. It is
operating at CWDM wavelengths according to ITU-T G.694.2. It provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias. It is intended for use in FSP 3000R7 modules with
SFP interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with SFP types approved by ADVA Optical
Networking only.

Table 746: Technical Data


Equipment type SFP-C
First release 8.1
Module type SFP
Weight 20 g
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 4,830,918 h
Optical connector type Duplex LC
Transmitter fiber type SM

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Receiver fiber type SM
Data rates 1.0625 Gbit/s, 2.125 Gbit/s,
4.250 Gbit/s
Transmitter output power range +2 dBm ... +5 dBm
Transmitter wavelengths depending 1471 nm, 1491 nm, 1511 nm, 1531 nm,
on respective SFP type 1551 nm, 1571 nm, 1591 nm, 1611 nm
according to ITU-T G.694.2
Min. extinction ratio 5 dB
Min. side mode suppression ratio 30 dB
Receiver wavelength range 1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm, 1611 nm
according to ITU-T G.694.2
Max. receiver reflectance 27 dB
Receiver dynamic range -23 dBm ... -9 dBm
(including dispersion penalties)
OPR/OPT accuracy +/- 3 dB
OPR measurement range -23 dBm ... -6 dBm
Min. dispersion load 0 ps/nm
Max. dispersion load 1400 ps/nm
Max. power penalty at dispersion 0 dB
Bit error ratio < 10-12

436 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP/4GU/CxxxxV/SM/LC (HW Rev. 3.01)

The SFP/4GU/CxxxxV/SM/LC (HW Rev. 3.01) is an MSA-compliant pluggable


transceiver for bidirectional communication over single-mode fiber. It is
operating at CWDM wavelengths according to ITU-T G.694.2. It provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias. It is intended for use in FSP 3000R7 modules with
SFP interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with SFP types approved by ADVA Optical
Networking only.

Table 747: Technical Data


Equipment type SFP-C
First release 9.3
Module type SFP
Weight 20 g
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 4,830,918 h
Optical connector type Duplex LC
Transmitter fiber type SM
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Receiver fiber type SM


Data rates 1.0625 Gbit/s, 2.125 Gbit/s,
4.250 Gbit/s
Transmitter output power range +1 dBm ... +5 dBm
Transmitter wavelengths depending 1471 nm, 1491 nm, 1511 nm, 1531 nm,
on respective SFP type 1551 nm, 1571 nm, 1591 nm, 1611 nm
according to ITU-T G.694.2
Min. extinction ratio 5 dB
Min. side mode suppression ratio 30 dB
Receiver wavelength range 1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm, 1611 nm
according to ITU-T G.694.2
Max. receiver reflectance 27 dB
Receiver dynamic range -23 dBm ... -9 dBm
(including dispersion penalties)
OPR/OPT accuracy +/- 3 dB
OPR measurement range -23 dBm ... -6 dBm
Min. dispersion load 0 ps/nm
Max. dispersion load 1400 ps/nm
Max. power penalty at dispersion 0 dB
Bit error ratio < 10-12

Module and System Specification 437


SFP/4GU/1310S/SM/LC

SFP/4GU/1310S/SM/LC
The SFP/4GU/1310S/SM/LC is an MSA-compliant pluggable 1310 nm
transceiver for bidirectional communication over single-mode fiber. It provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. It is intended for use in FSP 3000R7 modules
with SFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA
Optical Networking only.

Table 748: Technical Data


Equipment type SFP-G
First release 7.0
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection acc. to IEC IP20. Use in a pollution degree 2
60529 environment and indoor controlled office
environments only.
MTBF at 25°C ambient temperature 11,627,907 h
Optical connector type Duplex LC
Transmitter fiber type SM

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Receiver fiber type SM
Data rates 1.0625 Gbit/s, 2.125 Gbit/s, 4.250 Gbit/s
(1 Gbit/s Coupling Link is not supported)
Transmitter output power range -9 dBm ... -1 dBm
Transmitter wavelength range 1260 nm ... 1360 nm
Min. extinction ratio 3 dB
Receiver wavelength range 1260 nm ... 1360 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -18 dBm ... -1 dBm at 1.0625 Gbit/s,
2.125 Gbit/s
-15 dBm ... -1 dBm at 4.25 Gbit/s
OPR/OPT accuracy +/- 3 dB
OPR measurement range -18 dBm ... 2 dBm
Max. link distance 10 km at 1.0625 Gbit/s
10 km at 2.125 Gbit/s 
4 km at 4.250 Gbit/s
Bit error ratio < 10-12

438 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP/4GU/850I/MM/LC
The SFP/4GU/850I/MM/LC is an MSA-compliant pluggable 850 nm transceiver
for bidirectional communication over multimode fiber. It provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias. It is intended for use in FSP 3000R7 modules with
SFP interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with SFP types approved by ADVA Optical
Networking only.

Table 749: Technical Data


Equipment type SFP-G
First release 7.0
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 6,264,000 h
Optical connector type Duplex LC
Transmitter fiber type MM 62.5 µm
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Receiver fiber type MM 62.5 µm


MM 50 µm
Data rates 1.0625 Gbit/s, 2.125 Gbit/s, 
4.250 Gbit/s
Transmitter output power range -10 dBm ... -2.5 dBm
Transmitter wavelength range 830 nm ... 860 nm
Min. extinction ratio 3 dB
Receiver wavelength range 770 nm ... 860 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -19 dBm ... 0 dBm at 1.0625 Gbit/s
-17 dBm ... 0 dBm at 2.125 Gbit/s
-14 dBm ... 0 dBm at 4.250 Gbit/s
OPR/OPT accuracy +/- 3 dB
OPR measurement range -19 dBm ... 3 dBm
Max. link distance, 50 μm MM fiber 500 m at 1.0625 Gbit/s
300 m at 2.125 Gbit/s
150 m at 4.250 Gbit/s
Max. link distance, 62.5 μm MM fiber 300 m at 1.0625 Gbit/s
150 m at 2.125 Gbit/s
70 m at 4.250 Gbit/s
Bit error ratio < 10-12

Module and System Specification 439


SFP/4GU/CxxxxL/SM/LC

SFP/4GU/CxxxxL/SM/LC
The SFP/4GU/CxxxxL/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at CWDM
wavelengths according to ITU-T G.694.2. It provides digital diagnostic
monitoring of operating parameters such as optical input power, temperature or
laser bias. It is intended for use in FSP 3000R7 modules with SFP interface
cages. Proper functionality and valid certification of transponder modules can
be guaranteed with SFP types approved by ADVA Optical Networking only.

Table 750: Technical Data


Equipment type SFP-C
First release 7.1 (1471 nm - 1611 nm)
9.3 (1271 nm - 1451 nm)
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled office
environments only.
MTBF at 25°C ambient temperature
1271 nm - 1451 nm 2,816,901 h

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
1471 nm - 1611 nm 39,525,692 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 1.0625 Gbit/s, 2.125 Gbit/s, 4.250 Gbit/s
Transmitter output power range +1 dBm ... +5 dBm
Transmitter wavelengths 1471 nm, 1491 nm, 1511 nm, 1531 nm,
depending on respective SFP type 1551 nm, 1571 nm, 1591 nm, 1611 nm
according to ITU-T G.694.2
Min. extinction ratio 4 dB
Min. side mode suppression ratio 30 dB
Receiver wavelength range 1271 nm, 1291 nm, 1311 nm, 1331 nm,
1351 nm, 1371 nm, 1431 nm, 1451 nm,
1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm, 1611 nm
according to ITU-T G.694.2
Max. receiver reflectance 12 dB
Receiver dynamic range -16 dBm ... -6 dBm (1271 ... 1451 nm)
-16 dBm ... 0 dBm (1471 ... 1611 nm)
OPR/OPT accuracy +/- 3 dB
OPR measurement range -16 dBm ... -3 dBm (1271 ... 1451 nm)
-16 dBm ... 3 dBm (1471 ... 1611 nm)
Min. dispersion load 0 ps/nm
Max. dispersion load at 1611 nm 600 ps/nm

440 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 750: Technical Data (Continued)


Max. power penalty at dispersion 0 dB (see “Receiver dynamic range”)
Bit error ratio < 10-12
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 441


SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx

SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx
The SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx is an MSA-compliant pluggable
transceiver for bidirectional communication over single-mode fiber. It is
operating at DWDM wavelengths according to ITU-T G.694.1. It provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias. It is intended for use in FSP 3000R7 modules with
SFP interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with SFP types approved by ADVA Optical
Networking only.

Table 751: Technical Data


Equipment type SFP-D
First release 7.0
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled office
environments only.
MTBF at 25°C ambient 6,097,561 h
temperature

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 155 Mbit/s ... 2.67 Gbit/s up to HW Rev.
2.01 (1 Gbit/s Coupling Link is not
supported)

125 Mbit/s ... 2.67 Gbit/s from HW Rev.


3.01 (1 Gbit/s Coupling Link is not
supported)
Transmitter output power range +4 dBm ... +7 dBm
Transmitter wavelengths 82 channels, 100 GHz spacing in C and L
depending on resp. SFP type band acc. to ITU-T G.694.1
Wavelength stability (operating) +/- 100 pm
Transmitter wavelength accuracy +/- 0.1 nm
relative to nominal wavelength
Min. extinction ratio 8.2 dB
Min. side mode suppression ratio 30 dB
Receiver wavelength range 1270 nm ... 1620 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -28 ... -9 dBm unamplified
-28 ... -9 dBm at >23 dB OSNR at 0.1 nm
-27 ... -9 dBm at 22 dB OSNR at 0.1 nm
-26 ... -9 dBm at 21 dB OSNR at 0.1 nm
-25 ... -9 dBm at 20 dB OSNR at 0.1 nm

442 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 751: Technical Data (Continued)


Receiver dynamic range with -28 ... -9 dBm unamplified
GFEC -28 ... -9 dBm at >16 dB OSNR at 0.1 nm
-27 ... -9 dBm at 15 dB OSNR at 0.1 nm
-26 ... -9 dBm at 14 dB OSNR at 0.1 nm
-25 ... -9 dBm at 13 dB OSNR at 0.1 nm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -28 dBm ... -6 dBm
Optimum dispersion load range +100 ps/nm ... +800 ps/nm
Dispersion load range with 1 dB -500 ps/nm ... +100 ps/nm and 
OSNR penalty +800 ps/nm ... +1400 ps/nm
Dispersion load range with 2 dB -1100 ps/nm ... -500 ps/nm and 
OSNR penalty +1400 ps/nm ... +2000 ps/nm
Dispersion load range with 3 dB -1500 ps/nm ... -1100 ps/nm and 
OSNR penalty +2000 ps/nm ... +2400 ps/nm
OSNR PMD penalty 1 dB at 40 ps (outage probability 4x10-5)
Bit error ratio < 10-12
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 443


SFP/2G5U/CxxxxV/SM/LC

SFP/2G5U/CxxxxV/SM/LC
The SFP/2G5U/CxxxxV/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at CWDM
wavelengths according to ITU-T G.694.2. It provides digital diagnostic
monitoring of operating parameters such as optical input power, temperature or
laser bias. It is intended for use in FSP 3000R7 modules with SFP interface
cages. Proper functionality and valid certification of transponder modules can
be guaranteed with SFP types approved by ADVA Optical Networking only.

Table 752: Technical Data


Equipment type SFP-C
First release 7.0 (1471 nm - 1611 nm)
9.1 (1271 nm - 1451 nm)
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled office
environments only.
MTBF at 25°C ambient 3,331,001 h
temperature

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 100 Mbit/s ... 2.67 Gbit/s
Transmitter output power range 0 dBm ... +5 dBm
Transmitter wavelengths 1471 nm, 1491 nm, 1511 nm, 1531 nm,
depending on respective SFP 1551 nm, 1571 nm, 1591 nm, 1611 nm
type according to ITU-T G.694.2
Min. extinction ratio 8.2 dB
Min. side mode suppression ratio 30 dB
Receiver wavelength range 1271 nm, 1291 nm, 1311 nm, 1331 nm,
1351 nm, 1371 nm, 1431 nm, 1451 nm,
1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm, 1611 nm
according to ITU-T G.694.2
Max. receiver reflectance 27 dB
Receiver dynamic range -28 dBm ... -9 dBm
Receiver dynamic range for data -30 dBm ... -9 dBm
rates up to 1.25Gbit/s
OPR/OPT accuracy +/- 3 dB
OPR measurement range -33 dBm ... -6 dBm
Min. dispersion load -1250 ps/nm at 2.67 Gbit/s
(1471 nm ... 1611 nm)

444 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 752: Technical Data (Continued)


Min. dispersion load -300 ps/nm at 2.67 Gbit/s
(1271 nm ... 1451 nm)
Max. dispersion load 1600 ps/nm at 2.67 Gbit/s
(1471 nm ... 1611 nm) 2400 ps/nm at 1.25 Gbit/s
Max. dispersion load 800 ps/nm at 2.67 Gbit/s
(1271 nm ... 1451 nm) 1600 ps/nm at 1.25 Gbit/s
Max. power penalty at dispersion 2 dB at max. dispersion
2 dB at min. dispersion
Bit error ratio < 10-12
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 445


SFP/2G5U/CxxxxL/SM/LC

SFP/2G5U/CxxxxL/SM/LC
The SFP/2G5U/CxxxxL/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at CWDM
wavelengths according to ITU-T G.694.2. It provides digital diagnostic
monitoring of operating parameters such as optical input power, temperature or
laser bias. It is intended for use in FSP 3000R7 modules with SFP interface
cages. Proper functionality and valid certification of transponder modules can
be guaranteed with SFP types approved by ADVA Optical Networking only.

Table 753: Technical Data


Equipment type SFP-C
First release 7.0
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 3,465,723 h
Optical connector type Duplex LC

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmitter fiber type SM
Receiver fiber type SM
Data rates 100 Mbit/s ... 2.67 Gbit/s
Transmitter output power range 0 dBm ... +5 dBm
Transmitter wavelengths 1471 nm, 1491 nm, 1511 nm, 1531 nm,
depending on respective SFP type 1551 nm, 1571 nm, 1591 nm, 1611 nm
(according to ITU-T G.694.2)
Min. extinction ratio 8.2 dB
Min. side mode suppression ratio 30 dB
Receiver wavelength range 1471 nm, 1491 nm, 1511 nm, 1531 nm,
(according to ITU-T G.694.2) 1551 nm, 1571 nm, 1591 nm, 1611 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -20 dBm ... 0 dBm
Receiver dynamic range at GbE -23 dBm ... 0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -20 dBm ... 3 dBm
Min. dispersion load -1250 ps/nm
Max. dispersion load 1250 ps/nm
Max. power penalty at dispersion 2 dB at 1250 ps/nm
2 dB at -1250 ps/nm
Bit error ratio < 10-12

446 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP/2G5U/1310S/SM/LC (HW Rev. 2.01)

The SFP/2G5U/1310S/SM/LC is an MSA-compliant pluggable 1310 nm


transceiver for bidirectional communication over single-mode or multimode
fiber. It provides digital diagnostic monitoring of operating parameters such as
optical input power, temperature or laser bias. It is compliant to ITU-T G.957
SDH S-16.1 and Telcordia GR-253 SONET OC-48 IR-1. It is intended for use in
FSP 3000R7 modules with SFP interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP types
approved by ADVA Optical Networking only.

Table 754: Technical Data


Equipment type SFP-G
First release 10.1 (HW Rev. 2.01)
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection acc. to IEC IP20. Use in a pollution degree 2
60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 7,352,941 h
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Optical connector type Duplex LC


Transmitter fiber type SM
Receiver fiber type MM 62.5 µm
Data rates 100 Mbit/s ... 2.67 Gbit/s (1 Gbit/s
Coupling Link is not supported)
Transmitter output power range -5 dBm ... 0 dBm
Transmitter wavelength range 1260 nm ... 1360 nm
Min. extinction ratio 8.2 dB
Receiver wavelength range 1260 nm ... 1570 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -18 dBm ... 0 dBm
Receiver dynamic range at GbE -20 dBm ... 0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -20 dBm ... 3 dBm
Max. link distance single-mode fiber 15 km depending on customer
interface
Max. link distance multimode fiber 500 m depending on customer
interface
Max. link distance single-mode fiber 20 km depending on customer
at GbE interface
Max. link distance multimode fiber 600 m depending on customer
at GbE interface
Bit error ratio < 10-12

Module and System Specification 447


SFP/2G5U/1310L/SM/LC

SFP/2G5U/1310L/SM/LC
The SFP/2G5U/1310L/SM/LC is an MSA-compliant pluggable 1310 nm
transceiver for bidirectional communication over single-mode fiber. It provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. It is intended for use in FSP 3000R7 modules
with SFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA
Optical Networking only.

Table 755: Technical Data


Equipment type SFP-G
First release 7.0
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 3,322,259 h
Optical connector type Duplex LC
Transmitter fiber type SM

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Receiver fiber type SM
Data rates 100 Mbit/s ... 2.67 Gbit/s (1 Gbit/s
Coupling Link is not supported)
Transmitter output power range -2 dBm ... +3 dBm
Transmitter wavelength range 1260 nm ... 1360 nm
Min. extinction ratio 8.2 dB
Receiver wavelength range 1260 nm ... 1580 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -27 dBm ... -9 dBm
Receiver dynamic range at GbE -30 dBm ... -9 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -27 dBm ... -6 dBm
Max. link distance single-mode fiber 40 km depending on customer
interface
Max. link distance 9/125 μm SM at 50 km
GbE
Bit error ratio < 10-12

448 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP/3GSDI/#xxxxxV/SM/LC
The SFP/3GSDI/#xxxxxV/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at DWDM
wavelengths according to ITU-T G.694.1. The SFP/3GSDI/#xxxxxV/SM/LC
supports data rates for the transmission of SD-SDI, HD-SDI and 3G-SDI video
signals on the network ports.
This pluggable transceiver provides digital diagnostic monitoring of operating
parameters such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.

Table 756: Technical Data


Equipment type SFP-D
First release 11.2
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled office
environments only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

MTBF at 25°C ambient 24,213,075 h


temperature
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 270 Mbit/s, 360 Mbit/s, 1.485 Gbit/s, 
2.97 Gbit/s
Transmitter output power range 0 dBm ... +3 dBm
Transmitter wavelengths 41 channels, 100 GHz spacing in C band
depending on resp. SFP type acc. to ITU-T G.694.1
Wavelength stability (operating) +/- 125 pm
Min. extinction ratio 5 dB
Min. side mode suppression ratio 30 dB
Receiver wavelength range 1270 nm ... 1610 nm
Max. receiver reflectance 27 dB
Receiver dynamic range  -30 ... -9 dBm at 270 Mbit/s and 360 Mbit/s
(OSNR >30 dB) -29 ... -9 dBm at 1.485 Gbit/s
-28 ... -9 dBm at 2.97 Gbit/s
Receiver dynamic range  -28 ... -9 dBm at 270 Mbit/s and 360 Mbit/s
(OSNR >20 dB) -27 ... -9 dBm at 1.485 Gbit/s
Receiver dynamic range  -26 ... -9 dBm at 2.97 Gbit/s
(OSNR >25 dB)
OPR/OPT accuracy +/- 3 dB
OPR measurement range -32 dBm ... -7 dBm
Optimum dispersion load 0 ps/nm ...700 ps/nm

Module and System Specification 449


SFP/3GSDI/#xxxxxV/SM/LC

Table 756: Technical Data (Continued)


Dispersion load range with 2 dB -700 ps/nm ...0 ps/nm and 
OSNR penalty +700 ps/nm ... 1400 ps/nm
OSNR PMD penalty 1 dB at 40 ps (outage probability 4x10-5)
Bit error ratio < 10-12

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

450 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP/3GSDI/ELECTRICAL/DIN
The SFP/3GSDI/ELECTRICAL/DIN is an MSA SFF-8074 compliant pluggable
transceiver that provides an electrical DIN1.0/2.3 interface for the support of
SD-SDI, HD-SDI and 3G-SDI video signals. It is intended for use in FSP
3000R7 modules with SFP interface cages on the client ports. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.

Pluggable electrical transceivers must not be directly connected to


metallic tip and ring outside-plant conductors. They have to be used
only for inside-plant conductors.
WARNING

Table 757: Technical Data


Equipment type SFP-E
First release 11.2
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Degree of protection acc. to IEC IP20. Use in a pollution degree 2


60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 3,872,637 h
Electrical connector type DIN1.0/2.3
Cable type Belden 1694A coaxial cables, 75 Ω
Data rates 270 Mbit/s, 360 Mbit/s, 1.485 Gbit/s,
2.97 Gbit/s
Cable reach 400 m at 270 Mbit/s
300 m at 360 Mbit/s
140 m at 1.485 Gbit/s
120 m at 2.97 Gbit/s

Module and System Specification 451


SFP/3GSDI/ELECTRICAL/HBNC

SFP/3GSDI/ELECTRICAL/HBNC
The SFP/3GSDI/ELECTRICAL/HBNC is an MSA SFF-8074 compliant
pluggable transceiver that provides an electrical high-density BNC (HD-BNC)
interface for the support of SD-SDI, HD-SDI and 3G-SDI video signals. It is
intended for use in FSP 3000R7 modules with SFP interface cages on the client
ports. Proper functionality and valid certification of transponder modules can be
guaranteed with SFP types approved by ADVA Optical Networking only.

Pluggable electrical transceivers must not be directly connected to


metallic tip and ring outside-plant conductors. They have to be used
only for inside-plant conductors.
WARNING

Table 758: Technical Data


Equipment type SFP-E
First release 11.2
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Degree of protection acc. to IEC IP20. Use in a pollution degree 2
60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 3,872,637 h
Electrical connector type HD-BNC
Cable type Belden 1694A coaxial cables, 75 Ω
Data rates 270 Mbit/s, 360 Mbit/s, 1.485 Gbit/s,
2.97 Gbit/s
Cable reach 400 m at 270 Mbit/s
300 m at 360 Mbit/s
200 m at 1.485 Gbit/s
140 m at 2.97 Gbit/s

452 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP/HS/1310S/SM/LC
The SFP/HS/1310S/SM/LC is an MSA-compliant pluggable 1310 nm
transceiver for bidirectional communication over single-mode or multimode
fiber. It provides digital diagnostic monitoring of operating parameters such as
optical input power, temperature or laser bias. It is intended for use in FSP
3000R7 modules with SFP interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP types
approved by ADVA Optical Networking only.

Table 759: Technical Data


Equipment type SFP-G
First release 7.0
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 3,569,134 h
Optical connector type Duplex LC
Transmitter fiber type SM
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Receiver fiber type MM 62.5 µm


Data rates 1.0625 Gbit/s, 1.25 Gbit/s (1 Gbit/s
Coupling Link is not supported)
Transmitter output power range -10 dBm ... -3 dBm
Transmitter wavelength range 1260 nm ... 1360 nm
Min. extinction ratio 8.2 dB
Receiver wavelength range 1270 nm ... 1600 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -19 dBm ... -3 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -19 dBm ... 0 dBm
Max. link distance single-mode fiber 5 km depending on customer interface
Max. link distance multimode fiber 500 m depending on customer
interface
Bit error ratio < 10-12

Module and System Specification 453


SFP/CL/1310I/SM/LC

SFP/CL/1310I/SM/LC
The SFP/CL/1310I/SM/LC is an MSA-compliant pluggable 1310 nm transceiver
for bidirectional communication over single-mode or multimode fiber. It provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. It is intended for use in FSP 3000R7 modules
with SFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA
Optical Networking only.

Table 760: Technical Data


Equipment type SFP-G
First release 7.0
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 3,304,528 h
Optical connector type Duplex LC
Transmitter fiber type SM

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Receiver fiber type MM 62.5 µm
Data rates 100 Mbit/s ... 2,67 Gbit/s
Transmitter output power range -10 dBm ... -3 dBm
Transmitter wavelength range 1260 nm ... 1360 nm
Min. extinction ratio 8.2 dB
Receiver wavelength range 1266 nm ... 1580 nm
Max. receiver reflectance 14 dB
Receiver dynamic range -19 dBm ... -3 dBm for data rates up to
2.5 Gbit/s
OPR/OPT accuracy +/- 3 dB
OPR measurement range -19 dBm ... 0 dBm
Max. link distance single-mode fiber 2 km depending on customer interface
Max. link distance multimode fiber 500 m depending on customer
interface
Bit error ratio < 10-12

454 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP/2G1/850I/MM/LC
The SFP/2G1/850I/MM/LC is an MSA-compliant pluggable 850 nm transceiver
for bidirectional communication over multimode fiber. It provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias. It is intended for use in FSP 3000R7 modules with
SFP interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with SFP types approved by ADVA Optical
Networking only.

Table 761: Technical Data


Equipment type SFP-G
First release 7.0
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 5,703,856 h
Optical connector type Duplex LC
Transmitter fiber type MM 62.5 µm
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Receiver fiber type MM 62.5 µm


Data rates 1.0625 Gbit/s, 1.25 Gbit/s,
2.125 Gbit/s, 2.5 Gbit/s
Transmitter output power range -10 dBm ... -3 dBm
Transmitter wavelength range 830 nm ... 860 nm
Min. extinction ratio 8.2 dB
Receiver wavelength range 770 nm ... 860 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -15 dBm ... -3 dBm
Receiver dynamic range at  -20 dBm ... -3 dBm
1.25 Gbit/s
Receiver dynamic range at  -13 dBm ... -3 dBm
2.5 Gbit/s data rate with 8B/10B
coding when used in
WCA-PCN-2G5 in adaptive odd
clocked mode
OPR/OPT accuracy +/- 3 dB
OPR measurement range -20 dBm ... 0 dBm
Max. link distance 200 m multimode fiber, depending on
customer interface
500 m multimode fiber 50 μm (OM3) if
used in SCU/SCU-II

Module and System Specification 455


SFP/2G1/850I/MM/LC

Table 761: Technical Data (Continued)


Max. link distance at GbE
50/125 μm MMF 550 m
62.5/125 μm MMF 300 m depending on the customer
interface
Bit error ratio < 10-12

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

456 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP/GBE/1310S/SM/LC/TIN
The SFP/GBE/1310S/SM/LC/TIN is an MSA-compliant pluggable 1310 nm
transceiver for bidirectional communication over single-mode fiber. It provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. This pluggable transceiver supports an
operating temperature within the industrial temperature range (see Table 762).
It is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.

Table 762: Technical Data


Equipment type SFP-G
First release 10.2
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Industrial temperature range -40°C ... +85°C
(operating)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

MTBF at 25°C ambient temperature 3,219,575 h


Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rate 1.25 Gbit/s
Transmitter output power range -9 dBm ... -3 dBm
Transmitter wavelength range 1310 nm
Min. extinction ratio 9 dB
Receiver wavelength range 1260 nm ... 1360 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -20 dBm ... -3 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -19 dBm ... 0 dBm
Max. power penalty at dispersion 3 dB
Max. link distance 10 km
Bit error ratio < 10-12

Module and System Specification 457


SFP/GBE/1310L/SM/LC/TIN

SFP/GBE/1310L/SM/LC/TIN
The SFP/GBE/1310L/SM/LC/TIN is an MSA-compliant pluggable 1310 nm
transceiver for bidirectional communication over single-mode fiber. It provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. This pluggable transceiver supports an
operating temperature within the industrial temperature range (see Table 763).
It is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.

Table 763: Technical Data


Equipment type SFP-G
First release 10.2
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Industrial temperature range -40°C ... +85°C
(operating)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 3,597,122 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rate 1.25 Gbit/s
Transmitter output power range -5 dBm ... +2 dBm
Transmitter wavelength range 1310 nm
Min. extinction ratio 9 dB
Receiver wavelength range 1260 nm ... 1360 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -23 dBm ... -3 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -20 dBm ... 0 dBm
Max. power penalty at dispersion 3.3 dB
Max. link distance 9/125 μm SM at GbE 40 km
Bit error ratio < 10-12

458 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP/GBE/1550V/SM/LC/TIN
The SFP/GBE/1550V/SM/LC/TIN is an MSA-compliant pluggable 1550 nm
transceiver for bidirectional communication over single-mode fiber. It provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. This pluggable transceiver supports an
operating temperature within the industrial temperature range (see Table 764).
It is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.

Table 764: Technical Data


Equipment type SFP-G
First release 10.2
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Industrial temperature range -40°C ... +85°C
(operating)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

MTBF at 25°C ambient temperature 2,970,885 h


Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rate 1.25 Gbit/s
Transmitter output power range 0 dBm ... +5 dBm
Transmitter wavelength range 1550 nm
Min. extinction ratio 9 dB
Receiver wavelength range 1480 nm ... 1580 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -24 dBm ... -3 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -20 dBm ... 0 dBm
Max. power penalty at dispersion 2 dB
Bit error ratio < 10-12

Module and System Specification 459


SFP/GBE/850I/MM/LC/TIN

SFP/GBE/850I/MM/LC/TIN
The SFP/GBE/850I/MM/LC/TIN is an MSA-compliant pluggable 850 nm
transceiver for bidirectional communication over multimode fiber. It provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. This pluggable transceiver supports an
operating temperature within the industrial temperature range (see Table 765).
It is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.

Table 765: Technical Data


Equipment type SFP-G
First release 10.2
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Industrial temperature range -40°C ... +85°C
(operating)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 15,680,400 h
Optical connector type Duplex LC
Transmitter fiber type MM 62.5 µm
Receiver fiber type MM 62.5 µm
Data rate 1.25 Gbit/s
Transmitter output power range -9.5 dBm ... 0 dBm
Transmitter wavelength range 850 nm
Min. extinction ratio 9 dB
Receiver wavelength range 770 nm ... 860 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -17 dBm ... 0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -20 dBm ... 0 dBm
Max. power penalty at dispersion 2 dB
Max. link distance
50/125 μm MMF 550 m
Bit error ratio < 10-12

460 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP/GBE/B1310S/SM/LC
The SFP/GBE/B1310S/SM/LC is an MSA-compliant pluggable 1310 nm
transceiver for bidirectional communication over one single-mode fiber. It is
used in pair with a complementary bidirectional SFP which has a different
wavelength, e.g. the SFP/GBE/B1490S/SM/LC.
The SFP/GBE/B1310S/SM/LC provides digital diagnostic monitoring of
operating parameters such as optical input power, temperature or laser bias. It
is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.

Table 766: Technical Data


Equipment type SFP-B-G
First release 12.1
Module type SFP
Weight 20 g (0.04 lbs)
Maximum power consumption 1.5 W
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

MTBF at 25°C ambient temperature 14,492,753 h


Optical connector type Simplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rate 1250 Mbit/s
Transmitter output power range -9 dBm ... -3 dBm
Transmitter wavelength 1310 nm
Min. extinction ratio 6 dB
Receiver wavelength range 1480 nm ... 1500 nm
Max. receiver reflectance -12 dB
Receiver dynamic range -20 dBm ... -3 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -22 dBm ... 0 dBm
Max. link distance single-mode fiber 10 km depending on customer
interface
Bit error ratio < 10-12

Module and System Specification 461


SFP/GBE/B1490S/SM/LC

SFP/GBE/B1490S/SM/LC
The SFP/GBE/B1490S/SM/LC is an MSA-compliant pluggable 1490 nm
transceiver for bidirectional communication over one single-mode fiber. It is
used in pair with a complementary bidirectional SFP which has a different
wavelength, e.g. the SFP/GBE/B1310S/SM/LC.
The SFP/GBE/B1490S/SM/LC provides digital diagnostic monitoring of
operating parameters such as optical input power, temperature or laser bias. It
is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.

Table 767: Technical Data


Equipment type SFP-B-G
First release 12.1
Module type SFP
Weight 20 g (0.04 lbs)
Maximum power consumption 1.5 W
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 14,492,753 h
Optical connector type Simplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rate 1250 Mbit/s
Transmitter output power range -9 dBm ... -3 dBm
Transmitter wavelength 1490 nm
Min. extinction ratio 6 dB
Receiver wavelength range 1260 nm ... 1360 nm
Max. receiver reflectance -12 dB
Receiver dynamic range -20 dBm ... -3 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -22 dBm ... 0 dBm
Max. link distance single-mode fiber 10 km depending on customer
interface
Bit error ratio < 10-12

462 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP/GBE/B1310L/SM/LC
The SFP/GBE/B1310L/SM/LC is an MSA-compliant pluggable 1310 nm
transceiver for bidirectional communication over one single-mode fiber. It is
used in pair with a complementary bidirectional SFP which has a different
wavelength, e.g. the SFP/GBE/B1490L/SM/LC.
The SFP/GBE/B1310L/SM/LC provides digital diagnostic monitoring of
operating parameters such as optical input power, temperature or laser bias. It
is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.

Table 768: Technical Data


Equipment type SFP-B-G
First release 12.1
Module type SFP
Weight 20 g (0.04 lbs)
Maximum power consumption 1.5 W
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

MTBF at 25°C ambient temperature 15,873,015 h


Optical connector type Simplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rate 1250 Mbit/s
Transmitter output power range -3 dBm ... +2 dBm
Transmitter wavelength 1310 nm
Min. extinction ratio 6 dB
Receiver wavelength range 1480 nm ... 1500 nm
Max. receiver reflectance -12 dB
Receiver dynamic range -23 dBm ... -3 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -26 dBm ... 0 dBm
Max. link distance single-mode fiber 40 km depending on customer
interface
Bit error ratio < 10-12

Module and System Specification 463


SFP/GBE/B1490L/SM/LC

SFP/GBE/B1490L/SM/LC
The SFP/GBE/B1490L/SM/LC is an MSA-compliant pluggable 1490 nm
transceiver for bidirectional communication over one single-mode fiber. It is
used in pair with a complementary bidirectional SFP which has a different
wavelength, e.g. the SFP/GBE/B1310L/SM/LC.
The SFP/GBE/B1490L/SM/LC provides digital diagnostic monitoring of
operating parameters such as optical input power, temperature or laser bias. It
is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.

Table 769: Technical Data


Equipment type SFP-B-G
First release 12.1
Module type SFP
Weight 20 g (0.04 lbs)
Maximum power consumption 1.5 W
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 14,285,714 h
Optical connector type Simplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rate 1250 Mbit/s
Transmitter output power range -3 dBm ... +2 dBm
Transmitter wavelength 1490 nm
Min. extinction ratio 6 dB
Receiver wavelength range 1260 nm ... 1360 nm
Max. receiver reflectance -12 dB
Receiver dynamic range -23 dBm ... -3 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -26 dBm ... 0 dBm
Max. link distance single-mode fiber 40 km depending on customer
interface
Bit error ratio < 10-12

464 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP/GBE/Electrical/RJ45
The SFP/GBE/Electrical/RJ45 is a pluggable transceiver that provides an
electrical Gbit Ethernet port. It is intended for use in FSP 3000R7 modules with
SFP interface cages on client ports. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA
Optical Networking only.
This pluggable transceiver does not support link loss forwarding.

Pluggable electrical transceivers must not be directly connected to


metallic tip and ring outside-plant conductors. They have to be used
only for inside-plant conductors.
WARNING

Table 770: Technical Data


Equipment type SFP-E
First release 7.0
Module type SFP
Weight 20 g (0.04 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Degree of protection acc. to IEC IP20. Use in a pollution degree 2


60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 5,703,856 h
Electrical connector type RJ45
Cable type S/FTP (PiMF) CAT 6
Data rates 1000Base-T IEEE 802.3ab
Bit error ratio < 10-12

Module and System Specification 465


SFP/FE/C1490U/SM/LC

SFP/FE/C1490U/SM/LC
The SFP/FE/C1490U/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at 1490 nm. It
provides digital diagnostic monitoring of operating parameters such as optical
input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with SFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA
Optical Networking only.

Table 771: Technical Data


Equipment type SFP-C
First release 8.1
Module type SFP
Weight 25 g (0.06 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 5,703,856 h
Optical connector type Duplex LC
Transmitter fiber type SM

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Receiver fiber type SM
Data rates 125 Mbit/s
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelengths 1490 nm
Transmitter wavelength range -7 nm ... +7 nm relative to nominal
wavelength
Min. extinction ratio 9 dB
Receiver wavelength range 1480 nm ... 1530 nm
Max. receiver reflectance 25 dB
Receiver dynamic range -42 dBm ... -9 dBm (BER < 10-7)
OPR/OPT accuracy +/- 3 dB
OPR measurement range -42 dBm ... -20 dBm
Min. dispersion load -1850 ps/nm
Optimum dispersion load 0 ps/nm
Max. dispersion load +3700 ps/nm
Max. power penalty at dispersion 2 dB at -1850 ps/nm
2 dB at +3700 ps/nm

466 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP/FE/C1510U/SM/LC
The SFP/FE/C1510U/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at 1510 nm. It
provides digital diagnostic monitoring of operating parameters such as optical
input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with SFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA
Optical Networking only.

Table 772: Technical Data


Equipment type SFP-C
First release 7.1
Module type SFP
Weight 25 g (0.06 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 5,703,856 h
Optical connector type Duplex LC
Transmitter fiber type SM
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Receiver fiber type SM


Data rates 125 Mbit/s
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelengths 1510 nm
Transmitter wavelength range -7 nm ... +7 nm
relative to nominal wavelength
Min. extinction ratio 9 dB
Receiver wavelength range 1500 nm ... 1520 nm
Max. receiver reflectance 25 dB
Receiver dynamic range -42 dBm ... -9 dBm (BER < 10-7)
OPR/OPT accuracy +/- 3 dB
OPR measurement range -42 dBm ... -20 dBm
Min. dispersion load -2000 ps/nm
Optimum dispersion load 0 ps/nm
Max. dispersion load 4000 ps/nm
Max. power penalty at dispersion 2 dB at -2000 ps/nm
2 dB at +4000 ps/nm

Module and System Specification 467


SFP/FE/C1490V/SM/LC

SFP/FE/C1490V/SM/LC
The SFP/FE/C1490V/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at 1490 nm. It
provides digital diagnostic monitoring of operating parameters such as optical
input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with SFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA
Optical Networking only.

Table 773: Technical Data


Equipment type SFP-C
First release 8.2
Module type SFP
Weight 25 g (0.06 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 3,891,051 h
Optical connector type Duplex LC
Transmitter fiber type SM

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Receiver fiber type SM
Data rates 125 Mbit/s
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelength 1490 nm
Transmitter wavelength range -7 nm ... +7 nm
relative to nominal wavelength
Min. extinction ratio 9 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1480 nm ... 1540 nm
Max. receiver reflectance 25 dB
Receiver dynamic range -30 dBm ... 0 dBm (BER < 10-7)
OPR/OPT accuracy +/- 3 dB
OPR measurement range -30 dBm to -15 dBm
Min. dispersion load -1850 ps/nm
Optimum dispersion load 0 ps/nm
Max. dispersion load 4000 ps/nm
Max. power penalty at dispersion 2 dB at -1850 ps/nm
2 dB at +4000 ps/nm

468 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP/FE/C1510V/SM/LC
The SFP/FE/C1510V/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at 1510 nm. It
provides digital diagnostic monitoring of operating parameters such as optical
input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with SFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA
Optical Networking only.

Table 774: Technical Data


Equipment type SFP-C
First release 8.2
Module type SFP
Weight 25 g (0.06 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 3,891,051 h
Optical connector type Duplex LC
Transmitter fiber type SM
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Receiver fiber type SM


Data rates 125 Mbit/s
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelengths 1510 nm
Transmitter wavelength range -7 nm ... +7 nm
relative to nominal wavelength
Min. extinction ratio 9 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1500 nm ... 1520 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -30 dBm ... 0 dBm (BER < 10-7)
OPR/OPT accuracy +/- 3 dB
OPR measurement range -30 dBm to -15 dBm
Min. dispersion load -2000 ps/nm
Optimum dispersion load 0 ps/nm
Max. dispersion load 4000 ps/nm
Max. power penalty at dispersion 2 dB at -2000 ps/nm
2 dB at +4000 ps/nm

Module and System Specification 469


SFP/FE/D1528.77E/SM/LC

SFP/FE/D1528.77E/SM/LC
The SFP/FE/D1528.77E/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at
1528.77 nm. It provides digital diagnostic monitoring of operating parameters
such as optical input power, temperature or laser bias. It is intended for use in
FSP 3000R7 OSCM-PN modules. The SFP/FE/D1528.77E/SM/LC does not
support the intrusion detection functionality of the OSCM-PN.

Table 775: Technical Data


Equipment type SFP-D
First release 8.2
Module type SFP
Weight 25 g (0.06 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 2,270,000 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Data rates 125 Mbit/s
Transmitter output power range +4 dBm ... +7 dBm
Transmitter wavelengths 1528.77 nm
Transmitter wavelength range +0.1 nm relative to nominal wavelength
Min. extinction ratio 10 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1260 ... 1610 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -42 dBm ... -10 dBm (BER < 10-7)
OPR/OPT accuracy +/- 3 dB (for input power range
-40 ... -20 dBm only)
OPR measurement range -40 dBm ... -20 dBm
Min. dispersion load -2000 ps/nm
Optimum dispersion load 0 ps/nm
Max. dispersion load 4000 ps/nm
Max. power penalty at dispersion 2 dB at -2000 ps/nm
2 dB at +4000 ps/nm

470 Module and System Specification


Chapter 6 Pluggable Transceivers

SFP/FE/Dxxxx.xxV/SM/LC
The SFP/FE/Dxxxxx.xxV/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is available as
SFP/FE/D1531.12 V/SM/LC and SFP/FE/D1531.90V/SM/LC. It provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias. It is intended for use in FSP 3000R7 OSCM-PN
modules.

Table 776: Technical Data


Equipment type SFP-D
First release 11.2
Module type SFP
Weight 25 g (0.06 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 2,270,000 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Data rates 125 Mbit/s


Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelengths 1531.12 nm or 1531.90 nm
Transmitter wavelength range +60 pm relative to nominal wavelength
Min. extinction ratio 8 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1260 ... 1610 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -32 dBm ... -15 dBm (BER < 10-7) at
12 dB OSNR
OPR/OPT accuracy +/- 3 dB
OPR measurement range -35 dBm ... -15 dBm
Optimum dispersion load 0 ps/nm ... 800 ps/nm
Dispersion load range with 2 dB -1000 ps/nm ... 0 ps/nm and 
receive power penalty 800 ... 1600 ps/nm

Module and System Specification 471


CFP/112G/LR10R/SM/LC

CFP/112G/LR10R/SM/LC
The CFP/112G/LR10R/SM/LC is an CFP MSA-compliant transceiver 
(2 km) used to transmit high speed data rates of 103.125 Gbit/s and 111.81
Gbit/s for bidirectional communication over single-mode fiber. This CFP has an
integrated MUX and DEMUX filter for transmitting data signal divided into ten
optical WDM lanes supporting wavelengths. This transceiver provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias.
It is intended for use in FSP 3000R7 modules with CFP interface cages on client
ports. Proper functionality and valid certification of transponder modules can be
guaranteed with CFP types approved by ADVA Optical Networking only.

Table 777: Technical Data


Equipment type CFP-10-G
First release 11.1
Module type CFP
Max. weight 300 g (0.7 lbs)
Environmental conditions Telcordia SR-3580 level 3
(NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree
IEC 60529 2 environment and indoor

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
controlled office environments
only.
MTBF at 25°C ambient temperature 2,066,115 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Aggregate data rates 103.125 Gbit/s, 111.81 Gbit/s
Protocols 100 GbE, OTU4
Nominal data rates per optical lane
100 GbE 10.31 Gbit/s
OTU4 11.18 Gbit/s
Operating wavelengths 1523 nm, 1531 nm, 1539 nm, 
1547 nm, 1555 nm, 1563 nm, 
1571 nm, 1579 nm, 1587 nm, 
1595 nm
Transmitter output power range, each -4.5 dBm ... +3.5 dBm
lane1
Optical modulation amplitude, each lane -3.9 dBm ... +3.0 dBm
(OMA2)
Max. transmitter and dispersion penalty 2.5 dB
(TDP), each lane
Max. optical lane transmitter output power 4 dB
difference
Max. total average transmitter output 13.5 dBm
power
Min. extinction ratio 2.5 dB

472 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 777: Technical Data (Continued)


Min. sidemode suppression ratio 30 dB
Max. cold start transmitter power up time 120 s
Receiver dynamic range, each lane3 -9.5 dBm ... +3.5 dBm
Receiver dynamic range, each lane at  -5 dBm ... +3.5 dBm
> 2.5 dB extinction ratio
Receiver dynamic range, each lane -7.5 dBm ... +3 dBm
(OMA2)
Stressed receiver sensitivity (OMA2) -6 dBm
Max. receiver input power variation 5.5 dB
between any two lanes
Max. receiver reflectance -26 dB
Max. link distance 2 km
OPR/OPT accuracy +/-3 dB
Bit error ratio <10-12 at 100 GbE
Pre-Fec bit error ratio <10-12 at OTU4 with 1 dB
power penalty
<10-9 at OTU4
Max. module delay 200 ns
1. Transmitter output power range, each lane (min) is informative and not the
principal indicator of signal strength. A transmitter with output power below
this value cannot be compliant; however, a value above this does not ensure
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

compliance.

ER – 1 
OMA = P(optical1)-P(optical0) = 2 Pavg x  ---------------
2. -
 ER + 1
Pavg = Transmitter output power range
ER = Extinction ratio

3. Receiver dynamic range, each lane (min) is informative and not the principal
indicator of signal strength. A received power below this value cannot be
compliant; however, a value above this does not ensure compliance.

This table shows the faults reported for each of the 10 lanes contained within
the pluggable transceiver.

Table 778: Fault Monitoring


Physical layer Laser failure; Laser degrade (based on bias current);
Receiver clock synch failure; Loss of signal (LOS)

Module and System Specification 473


CFP/112G/LR10R/SM/LC

This table performance monitoring values reported for each of the 10 lanes
contained within the pluggable transceiver.

Table 779: Performance Monitoring


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high);
values except current values; Optical power Tx (current, low,
Fixed threshold crossing alerts and too mean, high)
high/too low available)
Physical layer (current values) LBCL
Physical layer LSRTEMP
(current values; Fixed threshold crossing
alerts and too high/too low available)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

474 Module and System Specification


Chapter 6 Pluggable Transceivers

CFP/112G/LR4/SM/LC
The CFP/112G/LR4/SM/LC is an MSA-compliant CFP transceiver used to
transmit high speed data rates of 103.125 Gbit/s and 111.81 Gbit/s for
bidirectional communication over single-mode fiber. This CFP has an integrated
MUX and DEMUX filter for transmitting data signal divided into four different
optical WDM lanes supporting wavelengths. It provides digital diagnostic
monitoring of operating parameters such as optical input power, optical output
power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with CFP interface cages on client
ports. Proper functionality and valid certification of transponder modules can be
guaranteed with CFP types approved by ADVA Optical Networking only.

The CFP/112G/LR4/SM/LC meets the specification according to


PS

IEEE Std 802.3ba-2010 (100GBASE-LR4).


Note

Table 780: Technical Data


Equipment type CFP-4-G
First release 11.1
Module type CFP
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Max. weight 300 g (0.7 lbs)


Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 102,092 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Aggregate data rates 103.125 Gbit/s, 111.81 Gbit/s
Protocols 100 GbE, OTU4
Nominal data rates per optical lane
100 GbE 25.78 Gbit/s
OTU4 27.95 Gbit/s
Operating wavelengths 1295.56 nm, 1300.05 nm, 
1304.58 nm, 1309.14 nm 
(according to ITU-T 694.1)
Transmitter output power range, -4.3 dBm ... +4.5 dBm
each lane1
Optical modulation amplitude -1.3 dBm ... +4.5 dBm
(OMA2), each lane
Max. transmitter and dispersion 2.2 dB
penalty (TDP), each lane

Module and System Specification 475


CFP/112G/LR4/SM/LC

Table 780: Technical Data (Continued)


Max. optical lane transmitter output 5 dB
power difference
Max. total average transmitter output 10.5 dBm
power
Min. extinction ratio 4 dB
Min. sidemode suppression ratio 30 dB
Max. cold start transmitter power up 120 s
time
Receiver dynamic range, each lane3 -10.5 dBm ... +4.5 dBm
Receiver dynamic range, each lane -8 dBm ... +4.5 dBm
at > 4 dB extinction ratio
Receiver dynamic range, each lane -8.6 dBm ... +4.5 dBm
(OMA2)
Stressed receiver sensitivity, each -6.8 dBm
lane (OMA2)
Max. receiver input power variation 5.5 dB
between any two lanes
Max. optical path penalty 1.5 dB
Max. receiver reflectance -26 dB
Max. link distance 10 km
OPR/OPT accuracy +/-3 dB
OPR measurement range -13.5 dBm to +7.5 dBm

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Bit error ratio <10-12 at 100 GbE
Pre-Fec bit error ratio <10-12 at OTU4 with 3 dB power
penalty
<10-5 at OTU4
Max. module delay 200 ns
1. Transmitter output power range, each lane (min) is informative and not the
principal indicator of signal strength. A transmitter with output power below
this value cannot be compliant; however, a value above this does not ensure
compliance.

2. OMA = P(optical1)-P(optical0) = 2 Pavg x  ---------------


ER – 1 
-
 ER + 1
Pavg = Transmitter output power range
ER = Extinction ratio

3. Receiver dynamic range, each lane (min) is informative and not the principal
indicator of signal strength. A received power below this value cannot be
compliant; however, a value above this does not ensure compliance.

476 Module and System Specification


Chapter 6 Pluggable Transceivers

This table shows the faults reported by each of the 4 optical lanes contained
within the pluggable transceiver.
Table 781: Fault Monitoring
Physical layer Laser failure;
Laser degrade (based on bias current);
Receiver clock synch failure;
Loss of signal (LOS)

This table shows the performance monitoring values reported for each of the 4
optical lanes within the pluggable transceiver.

Table 782: Performance Monitoring


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high);
values except current values; Optical power Tx (current, low,
Fixed threshold crossing alerts and too mean, high)
high/too low available)
Physical layer (current values) LBCL
Physical layer LSRTEMP
(current values; Fixed threshold crossing
alerts and too high/too low available)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 477


CFP/103G/SR10/MM/MPO

CFP/103G/SR10/MM/MPO
The CFP/103G/SR10/MM/MPO is an MSA-compliant CFP transceiver, SR10
type, used to transmit high speed data rate of 103.125 Gbit/s for bidirectional
communication over multimode fiber.
This CFP transceiver module offers ten independent transmit and receive
channels, each capable of 10.3 Gbit/s operation per lane to enable support for
103G (100GBASE-SR10) rate. It provides separate fibre connection per optical
lane through a single MPO24 port which connects to an industry standard 2x12
parallel multimode fiber cable (4 optical lanes are not used).
The CFP/103G/SR10/MM/MPO is intended for use in FSP 3000R7 modules
with CFP interface cages on client ports. Proper functionality and valid
certification of transponder modules can be guaranteed with CFP types
approved by ADVA Optical Networking only.

The CFP/103G/SR10/MM/MPO meets the specification according to


PS

IEEE Std 802.3ba-2010 (100GBASE-SR10).


Note

Table 783: Technical Data


Equipment type CFP-10-G
First release 12.1

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Module type CFP
Max. weight 300 g (0.7 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 1,769,171 h
Optical connector type MPO24
Transmitter fiber type MM
Receiver fiber type MM
Aggregate data rates 103.125 Gbit/s
Protocols 100 GbE
Nominal data rates per optical lane 10.3125 Gbit/s
100 GbE
Optical lane wavelengths range 840 nm to 860 nm
(according to IEEE 802.3ba-2010)
Transmitter output power range, -7.6 dBm ... +2.4 dBm
each lane1
Optical modulation amplitude -5.6 dBm ... +3 dBm
(OMA2), each lane
Max. transmitter and dispersion 3.5 dB
penalty (TDP), each lane
Max. optical lane transmitter output 4 dB
power difference

478 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 783: Technical Data (Continued)


Min. extinction ratio 3 dB
Max. cold start transmitter power up 120 s
time
Receiver dynamic range, each lane3 -9.5 dBm ... +2.4 dBm
Receiver dynamic range, each lane -7.5 dBm ... +3 dBm
(OMA2)
Stressed receiver sensitivity, each -5.4 dBm, maximum per lane
lane (OMA2)
Max. receiver reflectance -12 dB
Max. link distance 100 m (OM3) 
150 m (OM4)
Bit error ratio <10-12 at 100 GbE
Max. module delay 500 ns
1. Transmitter output power range, each lane (min) is informative and not the
principal indicator of signal strength. A transmitter with output power below
this value cannot be compliant; however, a value above this does not ensure
compliance.

2. OMA = P(optical1)-P(optical0) = 2 Pavg x  ---------------


ER – 1 
-
 ER + 1
Pavg = Transmitter output power
ER = Extinction ratio
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

3. Receiver dynamic range, each lane (min) is informative and not the principal
indicator of signal strength. A received power below this value cannot be
compliant; however, a value above this does not ensure compliance.

The following table lists the faults reported by each of the 10 optical lanes
contained within the CFP transceiver.
Table 784: Fault Monitoring
Physical layer Loss of signal (LOS)
(One defect instance supported per Loss of clock
optical lane of transceiver) Laser failure;

The following table provides information about the performance monitoring


values reported for each of the 10 optical lanes within the CFP transceiver.

Table 785: Performance Monitoring


Physical layer Temperature (TEMP)
(current values; Fixed threshold crossing
alerts and too high/too low available)

The front cover of the SH9HU shelf cannot be used due to the MPO
PS

cable connected to the CFP/103G/SR10/MM/MPO.


Note

Module and System Specification 479


CFP/4x28G/#19xxx-#19xxxL/SM/LC

CFP/4x28G/#19xxx-#19xxxL/SM/LC
The CFP/4x28G/#19xxx-#19xxxL/SM/LC is an MSA-compliant CFP transceiver
used to transmit high speed data rates of 103.125 Gbit/s and 111.81 Gbit/s for
bidirectional communication over single-mode fiber. For data transmission the
signal is divided into four optical WDM lanes supporting DWDM C-band
channels according to ITU-T G.694.1.
This type of CFP is available in five variants:
• CFP/4x28G/#19595-#19520L/SM/LC
• CFP/4x28G/#19515-#19440L/SM/LC
• CFP/4x28G/#19435-#19360L/SM/LC
• CFP/4x28G/#19355-#19280L/SM/LC
• CFP/4x28G/#19275-#19200L/SM/LC
Each variant supports fixed channel spacing at 100 GHz between the optical
lanes. The lanes can be tuned as a block to four different nominal frequencies in
a 50 GHz, 400 GHz or 450 GHz offset grid. Tuning is performed by setting the
frequency of the first optical lane in the system management using the NE
management tools. With these 5 variants and their tuning capabilities 80
wavelengths are supported in the C band.
The CFP/4x28G/#19xxx-#19xxxL/SM/LC provides digital diagnostic monitoring
of operating parameters such as optical input power, temperature or laser bias.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
It is intended for use in FSP 3000R7 modules with CFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with CFP types approved by ADVA Optical Networking only.
The optical performance values listed below are specified for a 50 GHz grid filter
system. The CFP/4x28G/#19xxx-#19xxxL/SM/LC can be used in a 100 GHz
grid filter system as well. In this case penalties have to be taken into account.
Contact ADVA Optical Networking’s Network Consulting for details, please.

Table 786: Technical Data


Equipment type 4CFP-D
First release 11.2
Module type CFP
Max. weight 300 g (0.661 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 1,190,000 hrs.
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Aggregate data rates 103.125 Gbit/s, 111.81 Gbit/s
Protocols 100 GbE, OTU4

480 Module and System Specification


Chapter 6 Pluggable Transceivers

Table 786: Technical Data (Continued)


Nominal data rates per optical lane
100 GbE 25.78 Gbit/s
OTU4 27.95 Gbit/s
Operating frequency range Lanes are tunable to 4 different
nominal frequencies in a 50 GHz,
400 GHz or 450 GHz offset grid;
5 variants are available:
CFP/4x28G/#19595-#19520L/SM/LC 195.95 THz to 195.20 THz
CFP/4x28G/#19515-#19440L/SM/LC 195.15 THz to 194.40 THz
CFP/4x28G/#19435-#19360L/SM/LC 194.35 THz to 193.60 THz
CFP/4x28G/#19355-#19280L/SM/LC 193.55 THz to 192.80 THz
CFP/4x28G/#19275-#19200L/SM/LC 192.75 THz to 192.00 THz
Wavelength stability (operating) +/- 60 pm
Operating Rx wavelength range 1529 nm to 1562 nm
Transmitter output power range, each 0 dBm ... 3 dBm
lane
Max. optical lane transmitter output 2 dB
power difference
Min. sidemode suppression ratio 35 dB
Max. cold start transmitter power up 120 s
time
Receiver dynamic range, each lane -10 dBm ... +3 dBm1
Optimum dispersion load range -250 ps/nm to +250 ps/nm
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Dispersion load range with 1 dB OSNR -400 ps/nm to -250 ps/nm and
penalty +250 ps/nm to +400 ps/nm
OSNR penalty
at 2.3 ps PMD for BER < 10-3 1 dB (outage probability 4x10-5)
at 3.3 ps PMD for BER < 10-3 2 dB (outage probability 4x10-5)
at 4.6 ps PMD for BER < 10-3 4 dB (outage probability 4x10-5)
at 2.3 ps PMD for BER < 5 x 10-5 1.5 dB (outage probability 4x10-5)
at 3.3 ps PMD for BER < 5 x 10-5 2.5 dB (outage probability 4x10-5)
at 4.6 ps PMD for BER < 5 x 10-5 4.5 dB (outage probability 4x10-5)
OPR/OPT accuracy +/-3 dB
Bit error ratio < 5 x 10-5 at 23 dB OSNR (0.1 nm)
<10-3 at 19 dB OSNR (0.1 nm)
Max. module delay 200 ns

The receiver performance values assume that the optimum receiver


PS

threshold is set by host for all operating conditions.


Note

Module and System Specification 481


CFP/4x28G/#19xxx-#19xxxL/SM/LC

This table shows the faults reported by each of the optical lanes contained
within the pluggable transceiver.
Table 787: Fault Monitoring
Physical layer Laser failure;
Laser degrade (based on bias current);
Receiver clock synch failure;
Loss of signal

This table shows the performance monitoring values reported for each of the
optical lanes within the pluggable transceiver.

Table 788: Performance Monitoring


Physical layer Transmitter bias current (current);
(15 min/24 h records available for PM Optical power Rx (current, low,
values except current values; mean, high);
user configurable threshold crossing alerts
for OPR too high/too low available;
Fixed threshold crossing alerts for OPT Optical power Tx (current, low,
too high/too low available) mean, high)
Physical layer (current values) LBCL
Physical layer LSRTEMP
(current values; Fixed threshold crossing
alerts and too high/too low available)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

482 Module and System Specification


Chapter 6 Pluggable Transceivers

CFP/4x28G/#DCTL/SM/LC
The CFP/4x28G/#DCTL/SM/LC is an MSA-compliant CFP transceiver used to
transmit high speed data rates of 103.125 Gbit/s and 111.81 Gbit/s for
bidirectional communication over single-mode fiber. For data transmission the
signal is divided into four optical WDM lanes supporting DWDM C-band
channels according to ITU-T G.694.1.
This transceiver supports fixed channel spacing at 100 GHz between four
optical lanes. The lanes can be tuned as a block to 90 different nominal
frequencies at a 50 GHz channel grid between 196.00 THz and 191.25 THz.
Tuning is performed by setting the frequency of the first optical lane in the
system management using the NE management tools.
The CFP/4x28G/#DCTL/SM/LC provides digital diagnostic monitoring of
operating parameters such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with CFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with CFP types approved by ADVA Optical Networking only.
The optical performance values listed below are specified for a 50 GHz grid filter
system. The CFP/4x28G/#DCTL/SM/LC can be used in a 100 GHz grid filter
system as well. In this case penalties have to be taken into account. Contact
ADVA Optical Networking’s Network Consulting for details, please.

Table 789: Technical Data


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Equipment type 4CFP-D


First release 11.2
Module type CFP
Max. weight 300 g (0.661 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 1,190,000 hrs.
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Aggregate data rates 103.125 Gbit/s, 111.81 Gbit/s
Protocols 100 GbE, OTU4
Nominal data rates per optical lane
100 GbE 25.78 Gbit/s
OTU4 27.95 Gbit/s
Operating frequency range The tuning range covers 90
different stages, resulting in the
support of 96 frequencies in a 50
GHz grid from 196.00 THz to
191.25 THz.1
Wavelength stability (operating) +/- 60 pm

Module and System Specification 483


CFP/4x28G/#DCTL/SM/LC

Table 789: Technical Data (Continued)


Operating Rx wavelength range 1529.55 nm to 1567.52 nm
Transmitter output power range, each 0 dBm ... 3 dBm
lane
Max. optical lane transmitter output 2 dB
power difference
Min. sidemode suppression ratio 35 dB
Max. cold start transmitter power up 120 s
time
Receiver dynamic range, each lane -10 dBm ... +3 dBm1

Optimum dispersion load range -250 ps/nm to +250 ps/nm


Dispersion load range with 1 dB OSNR -400 ps/nm to -250 ps/nm and
penalty +250 ps/nm to +400 ps/nm
OSNR penalty
at 2.3 ps PMD for BER < 10-3 1 dB (outage probability 4x10-5)
at 3.3 ps PMD for BER < 10-3 2 dB (outage probability 4x10-5)
at 4.6 ps PMD for BER < 10-3 4 dB (outage probability 4x10-5)
at 2.3 ps PMD for BER < 5 x 10-5 1.5 dB (outage probability 4x10-5)
at 3.3 ps PMD for BER < 5 x 10-5 2.5 dB (outage probability 4x10-5)
at 4.6 ps PMD for BER < 5 x 10-5 4.5 dB (outage probability 4x10-5)
OPR/OPT accuracy +/-3 dB

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Bit error ratio < 5 x 10-5 at 23 dB OSNR (0.1 nm)
<10-3 at 19 dB OSNR (0.1 nm)
Max. module delay 200 ns
1. Tuning to 96 channels is possible with NE SW 12.1 or higher. NE SW 11.2.3
allows tuning to 8o channels only.

The receiver performance values assume that the optimum receiver


PS

threshold is set by host for all operating conditions.


Note

This table shows the faults reported by each of the optical lanes contained
within the pluggable transceiver.
Table 790: Fault Monitoring
Physical layer Laser failure;
Laser degrade (based on bias current);
Receiver clock synch failure;
Loss of signal (LOS)

484 Module and System Specification


Chapter 6 Pluggable Transceivers

This table shows the performance monitoring values reported for each of the
optical lanes within the pluggable transceiver.

Table 791: Performance Monitoring


Physical layer Transmitter bias current (current);
(15 min/24 h records available for PM Optical power Rx (current, low,
values except current values; mean, high);
user configurable threshold crossing alerts
for OPR too high/too low available;
Fixed threshold crossing alerts for OPT Optical power Tx (current, low,
too high/too low available) mean, high)
Physical layer (current values) LBCL
Physical layer LSRTEMP
(current values; Fixed threshold crossing
alerts and too high/too low available)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 485


486
CFP/4x28G/#DCTL/SM/LC

Module and System Specification


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Chapter 7

Management and Switch Modules


This chapter describes management and switch modules of the FSP 3000R7.
The following sections are provided:
“NCU-II” on p. 488
“NCU-II-P” on p. 490
“UTM” on p. 492
“PSCU” on p. 494
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

“SCU” on p. 495
“SCU-II” on p. 497
“SCU-S” on p. 499
“VSM” on p. 501
“RSM-OLM#1630” on p. 503
“OSCM-PN” on p. 505

Module and System Specification 487


NCU-II

NCU-II
The network element control unit of the second generation (NCU-II) provides
the FSP 3000R7 System with a network connection and system management
capabilities.
An FSP 3000R7 node is managed via the NCU-II. This interface uses Internet
protocols to provide management and configuration capabilities. The NCU-II
controls the modules in its own shelf and those in the other shelves on one node
via the shelf control unit (SCU/SCU-S/SCU-II). Only one NCU-II is supported
per node.
The NCU-II is accessible via a terminal program or Ethernet using telnet, FTP,
HTTP, SCP, SNMP and NTP.
The NCU-II’s command line system allows fast (local) interaction. External
Network Management Systems (NMSs) are supported via SNMP over the
Ethernet interface.
Table 792 provides general information about the module and its environment.

Table 792: General Information


Equipment type NCU-II
First release 9.2
Width 4 HP
Height 2.5 HU

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Weight 310 g (0.7 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Typ. power consumption 6 W (NCU-II used in one shelf and
with 25°C ambient temperature)
Max. power consumption 9W
Max. available RAM (excluding 900000 Kbytes
tolerance buffer, RAM disk, initial
RAM consumption)
MTBF at 25°C ambient temperature 531,251 h
Slot position SH9HU, SH7HU, SH7HU-R,
SH1HU-HP/2DC, SH1HU-F/2DC,
SH1HU-HP/E-TEMP/2DC, SH1HU-R
and SH1HU-R/PF: slot A

The following table contains information about the ethernet interfaces.

Table 793: Ethernet Interfaces


Number of interfaces 2
Electrical connector type RJ45
Cable category CAT5E

488 Module and System Specification


Chapter 7 Management and Switch Modules

Table 793: Ethernet Interfaces (Continued)


Cable type unshielded for cable length: < 3 m
shielded (S/FTP) for cable length: 3 m to 100
m1
Max. link distance 100 m
Performance 10/100 Mbit/s Fast Ethernet half/full duplex
10/100 Mbit/s auto-negotiation can be disabled
Automatic MDI/MDI-X crossover capabilities
1. Only shielded cables have to be used for connections to third party
equipment.

This table provides information about the USB interfaces.

Table 794: USB Interfaces


Number of interfaces 1
Electrical connector type Mini-A/B
Cable type standard host USB-A to slave Mini-B
Performance USB Slave
USB spec. 2.0 compliant
provides only USB to RS232
emulation
Can be disabled
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

This table shows information about the serial interface.

Table 795: Serial Interface


Number of interfaces 1
Electrical connector type DE9M
Cable type standard serial DE9M
Performance Standard RS232
19200 Bd.
Can be disabled

The following table contains information about the hardware reset possibility.

Table 796: Reset


Hardware reset Push-button 1

This table gives information about the module monitoring.

Table 797: Module Monitoring


Temperature board temperature in °C
Voltage power fail

For information about DCN restrictions related to the use of NCU-II,


PS

please refer to the Planning and Engineering Guide.


Note

Module and System Specification 489


NCU-II-P

NCU-II-P
The network element control unit (NCU-II-P) provides system management
capabilities and network connection to the FSP 3000R7 system. The NCU-II-P
is a single-slot full height (5HU) plug-in module, that acts as the main network
element controller and offers different management interfaces (SNMP, WEB,
Craft, TL1, etc) to the outside world via ethernet, serial or in-band management
connections. It interfaces with and controls all equipment in the system. The
NCU-II-P can be used only in a redundant configuration together with another
NCU-II-P in one shelf to protect against single point of communication failures.
Please note: Continuous operation of a single NCU-II-P in a shelf is not
intended. The NCU-II-P always waits for a second standby NCU-II-P in the
same shelf.
The NCU-II-P only works with the second-generation shelf control unit (SCU-II).
The NCU-II-P communicates with the SCU-II in the master shelf using an inter-
nal system bus. Exchange of information between the SCU-II in the master shelf
and the SCU-IIs in the additional shelves takes place over the management
fiber ring.
The NCU-II-P can be accessed through a serial, Mini USB or Ethernet port.
Table 798 provides general information about the module and its environment.

Table 798: General Information

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Equipment type NCU-II-P
First release 11.2
Width 4 HP
Height 5 HU
Weight 500 g (1.102 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Typ. power consumption 9 W (NCU-II-P used in one shelf and
with 25°C ambient temperature)
Max. power consumption 11 W
Max. available RAM (excluding 2 Gbit
tolerance buffer, RAM disk, initial
RAM consumption)
MTBF at 25°C ambient temperature 446,428 h
Slot positions SH9HU: slots 3 and 18 in shelf #1

The following table contains information about the ethernet interfaces.

Table 799: Ethernet Interfaces


Number of interfaces 3
Electrical connector type RJ-45
Cable category CAT5E

490 Module and System Specification


Chapter 7 Management and Switch Modules

Table 799: Ethernet Interfaces (Continued)


Cable type unshielded for cable length: < 3 m
shielded (S/FTP) for cable length: 3 m to 100 m1
Max. link distance 100 m
Performance 10/100 Mbit/s Fast Ethernet half/full duplex
10/100 Mbit/s auto-negotiation can be disabled
Automatic MDI/MDI-X crossover capabilities
1. Only shielded cables have to be used for connections to third party
equipment.

This table provides information about the USB interfaces.

Table 800: USB Interfaces


Number of interfaces 1
Electrical connector type Mini-A/B
Cable type standard host USB-A to slave Mini-B
Performance USB Slave
USB spec. 2.0 compliant
provides only USB to RS232
emulation
Can be disabled

This table shows information about the serial interface.


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 801: Serial Interface


Number of interfaces 1
Electrical connector type DE9M
Cable type standard serial DE9M
Performance Standard RS232
19200 Bd.
Can be disabled

The following table contains information about the hardware reset possibility.

Table 802: Reset


Hardware reset Push-button
S/O Switch Over Push-button

This table gives information about the module monitoring.

Table 803: Module Monitoring


Temperature board temperature in °C
Voltage power fail

For information about DCN restrictions related to the use of NCU-II-P,


PS

please refer to the FSP 3000R7 Planning and Engineering Guide.


Note

Module and System Specification 491


UTM

UTM
The UTM (Utility Module) features 3 Ethernet interfaces for management access
and a telemetry interface with dry contacts for 16 external opto-isolated inputs
and 4 output signals. The alarm status of these input/output signals is visualized
to the user via 20 LEDs. An alarm reset button allows resetting the alarm status
of the output contacts as well as the associated output LEDs. It does not clear
the alarm status of the affected alarms in the management system.
Table 804 shows general information about the UTM and its environment.

Table 804: General Information


Equipment type UTM
First release 8.2
Width 4 HP
Height 5 HU
Weight 450 g (1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Typ. power consumption 7W

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Max. power consumption 10 W
Maximum RAM consumption on 269 Kbytes
NCU
MTBF at 25°C ambient temperature 548,507 h
Slot position SH9HU, SH7HU, SH7HU-R: 3...18
SH1HU: slot 1, 2

The following table contains information about the ethernet interfaces.

Table 805: Ethernet Interfaces


Number of interfaces 3
Electrical connector type RJ45
Cable category CAT5E
Cable type unshielded for cable length: < 3 m
shielded (S/FTP) for cable length: 3 m to 100 m
Max. link distance 100 m
Performance 10/100 Mbit/s Fast Ethernet half/full duplex
10/100 Mbit/s auto-negotiation can be disabled
Automatic MDI/MDI-X crossover capabilities

This table provides information about the telemetry interface.

Table 806: Telemetry Interface


Number of interfaces 1
Connector type HD SUB-D 44

492 Module and System Specification


Chapter 7 Management and Switch Modules

Table 806: Telemetry Interface (Continued)


Cable type proprietary cable,
25 m (984.25”) link distance,
shielded,
stranded copper wire with a diameter
of 1.1 mm (0.043”),
AWG24,
compliant to UL1061, UL2464 and 
VDE 0881
Number of alarm inputs 16
Number of alarm outputs 4

The following table shows information about telemetry alarm input parameters.

Table 807: Telemetry Alarm Input Parameters


Description Pin pairs connected to an opto coupler
isolated voltage source (from DC-DC
converter). Inputs can be configured to
create an alarm if a contact is closed or
opened.
Max. voltage on open input pin < 5 V DC
Max. current through a closed < 15 mA
external switch
Alarms Inputs can be configured to create an
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

alarm if the contact is closed or opened.

This table provides information about telemetry alarm output parameters.

Table 808: Telemetry Alarm Output Parameters


Max. switching voltage 42 V AC, 60 V DC
Max. switching power 50 VA AC, 60 W DC
Min. permissible load > 10 µA at 10 mV DC
Max. contact resistance < 50 mOhm
Max. operating frequency < 1800 op/hr

The following table contains information about the hardware reset possibility.

Table 809: Reset


Alarm reset Push-button

This table gives information about the module monitoring.

Table 810: Module Monitoring


Temperature board temperature in °C
Voltage power fail

Module and System Specification 493


PSCU

PSCU
The PSCU (Passive Shelf Control Unit) acts as the controller for
40CSM/2HU-#Dxx-#Dyy and 96CSM/4HU-#19600-#19125 shelves. The PSCU
recognizes all available 40CSM/2HU-#Dxx-#Dyy shelves and allows monitoring
and controlling. The PSCU is the connecting point of any
40CSM/2HU-#Dxx-#Dyy and 96CSM/4HU-#19600-#19125 shelf to support
management functionality. It basically registers the shelf to the NE controller
and provides inventory data and power supply. A maximum of eight
40CSM/2HU-#Dxx-#Dyy and 96CSM/4HU-#19600-#19125 shelves can be
connected to one PSCU via the interconnect ports.
Table 811 provides general information about the module and its environment.

Table 811: General Information


Equipment type PSCU
First release 8.2
Width 4 HP
Height 5 HU
Weight 500 g (1.1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
office environments only.
Typ. power consumption 3 W (+ 0.5 W per 40CSM shelf)
Max. power consumption 10 W
Maximum RAM consumption on 91 Kbytes
NCU
MTBF at 25°C ambient temperature 1,476,814 h
Slot position SH9HU, SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

Table 812 provides information about the interconnect ports.

Table 812: Ports


Number of interfaces 8
Interface types Support of 8 management interfaces
(interconnect ports)

Table 813 provides information about the module monitoring.

Table 813: Module Monitoring


Temperature board temperature in °C

494 Module and System Specification


Chapter 7 Management and Switch Modules

SCU
The Shelf Control Unit (SCU) supports the internal and external communication
of a shelf. It is responsible for module registration/deregistration and module
extraction supervision. The SCU provides redundant inter-shelf communication.
Table 814 provides general information about the module and its environment.

Table 814: General Information


Equipment type SCU
First release 7.0
Width 4 HP
Height 2.5 HU
Weight (equipped with 3 SFPs) 310 g (0.7 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Typ. power consumption 11 W
Max. power consumption 15 W
MTBF at 25°C ambient temperature 968,992 h
Maximum RAM consumption on 116 Kbytes
NCU
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Slot position SH9HU, SH7HU, SH7HU-R,


SH1HU-F/2DC, SH1HU-HP/2DC,
SH1HU-R, and SH1HU-R/PF: slot B

Table 815 provides information about the available ports.

Table 815: Ports


Number of interfaces 3
Interface types SFP
Fiber types 50 µm / 62.5 µm MM for
SFP/2G1/850I/MM/LC 
(HW Rev. 1.02 or newer) and
SFP/2G5U/1310S/SM/LC 
(HW Rev. 2.01)

SM for SFP/2G5U/1310S/SM/LC 
(HW Rev. 2.01)
Max. link distance 200 m with 62.5 µm MM
500 m with 50 µm MM (OM3)
15 km with SM between two shelves
(The total fiber length between all
shelves in one network element must
not exceed 35 km.)

Module and System Specification 495


SCU

Table 816 provides information about the port performance.

Table 816: Port Performance


Port U redundant 1.25 Gbit/s optical connection
between main and master shelves
Port D redundant 1.25 Gbit/s optical connection
between main and master shelves
Port X not used

Table 817 provides information about the supported SFPs.

Table 817: Supported SFPs


Port U SFP/2G1/850I/MM/LC
(HW Rev. 1.02 or newer)
SFP/2G5U/1310S/SM/LC
(HW Rev. 2.01)
Port D SFP/2G1/850I/MM/LC
(HW Rev. 1.02 or newer)
SFP/2G5U/1310S/SM/LC
(HW Rev. 2.01)
Port X -

Table 818 provides information about the module monitoring.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 818: Module Monitoring
Temperature board temperature in °C
Voltage power fail
Monitored states SFP state, link state

496 Module and System Specification


Chapter 7 Management and Switch Modules

SCU-II
The SCU-II (shelf control unit second generation) is a single-slot 2.5 HU high
plug-in module, which acts as a communication gateway between the NCU and
modules for an entire main shelf. It recognizes all inserted optical modules and
downloads their configuration data stored in the NCU. The SCU-II has
increased RAM, ROM and CPU performance and is fully compatible with other
SCUs. The module is also designed to operate with the NCU-II-P in redundant
configurations.
Table 819 provides general information about the module and its environment.

Table 819: General Information


Equipment type SCU-II
First release 11.2
Width 4 HP
Height 2.5 HU
Weight (equipped with 2 SFPs) 310 g (0.683 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Typ. power consumption 10 W
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Max. power consumption 11 W


MTBF at 25°C ambient temperature 587,199 h
Maximum RAM consumption on 91 Kbytes
NCU
Slot positions SH9HU, SH7HU, SH7HU-R,
SH1HU-F/2DC, SH1HU-HP/2DC,
SH1HU-R, and SH1HU-R/PF: slot B
In redundant SCU configurations:
slots A and B in SH7HU, and SH9HU
shelves.
NCU types NCU-II, NCU-II-P

Table 820 provides information about the available ports.

Table 820: Ports


Number of interfaces 2
Interface types SFP

Module and System Specification 497


SCU-II

Table 820: Ports (Continued)


Fiber types 50 µm / 62.5 µm MM for SFP/2G1/850I/MM/LC 
(HW Rev. 1.02 or newer) and
SFP/2G5U/1310S/SM/LC (HW Rev. 2.01)

SM for SFP/2G5U/1310S/SM/LC 
(HW Rev. 2.01)
Max. link distance 200 m with 62.5 µm MM
500 m with 50 µm MM (OM3)
15 km with SM between two shelves (The total
fiber length between all shelves in one network
element must not exceed 35 km.)

Table 821 provides information about the port performance.

Table 821: Port Performance


Port U redundant 1.25 Gbit/s optical connection
between main and master shelves
Port D redundant 1.25 Gbit/s optical connection
between main and master shelves

Table 822 provides information about the supported SFPs.

Table 822: Supported SFPs

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Port U SFP/2G1/850I/MM/LC
(HW Rev. 1.02 or newer)
SFP/2G5U/1310S/SM/LC
(HW Rev. 2.01)
Port D SFP/2G1/850I/MM/LC
(HW Rev. 1.02 or newer)
SFP/2G5U/1310S/SM/LC
(HW Rev. 2.01)

Table 823 provides information about the module monitoring.

Table 823: Module Monitoring


Temperature board temperature in °C
Voltage power fail
Monitored states SFP state, link state

498 Module and System Specification


Chapter 7 Management and Switch Modules

SCU-S
The Shelf Control Unit (SCU-S) supports the internal and external
communication of the SH1HU shelves. It is responsible for module
registration/deregistration and module extraction supervision. The SCU-S
provides inter-shelf communication. A maximum of two SH1HU shelves can be
connected to build one Network Element.
Table 824 provides general information about the module and its environment.

Table 824: General Information


Equipment type SCU-S
First release 8.1.1
Width 4 HP
Height 2.5 HU
Weight 200 g (0.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Typ. power consumption 3W
Max. power consumption 4W
MTBF at 25°C ambient temperature 509,972 h
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Maximum RAM consumption on 43 Kbytes


NCU
Slot position SH1HU-F/2DC, SH1HU-HP/2DC,
SH1HU-HP/E-TEMP/2DC, SH1HU-R,
and SH1HU-R/PF: slot B
NCU types NCU, NCU-II

Table 825 provides information about the available ports.

Table 825: Ports


Number of interfaces 2
Ethernet interface RJ45
Max. link distance 100 m

Table 826 provides information about the port performance.

Table 826: Port Performance


Port UP redundant fast Ethernet between main
and master shelves
Port DOWN redundant fast Ethernet between main
and master shelves

Module and System Specification 499


SCU-S

Table 827 provides information about the module monitoring.

Table 827: Module Monitoring


Temperature board temperature in °C
Voltage power fail
Monitored states link state

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

500 Module and System Specification


Chapter 7 Management and Switch Modules

VSM
The Versatile Switch Module (VSM) is for optically switched protection
purposes. In the case of a network failure the VSM gets messages from the
2OSCM-V#1630 or OSCM-PN to process protection switching.
These commands are transmitted via the internal communication system
(backplane and SCU-SCU). Only in configurations with 2OSCM-V#1630 or
OSCM-PN, equipped with two network SFPs, the backup path can be
monitored. The VSM can work on a line, band, subband, group or channel
basis. It can be deployed in protected point-to-point topologies as well as in ring
topologies.
Table 828 provides general information about the module and its environment.

Table 828: General Information


Equipment type VSM
First release 7.0
Width 4 HP
Height 5 HU
Weight 480 g (1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

office environments only.


MTBF at 25°C ambient temperature 212,224 h
Typ. power consumption 3.5 W
Max. power consumption 4W
Maximum RAM consumption on 93 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

Table 829 provides information about the available ports.

Table 829: Ports


Optical connector type Duplex LC
Fiber type G.652
IN 2x duplex optical ports
OUT 2x duplex optical ports

Table 830 provides information about the optical specification.

Table 830: Optical Specification


Wavelength range 1310 nm ... 1630 nm
Insertion loss 1.6 dB
any client port to any network port
Max. switching time 50 ms

Module and System Specification 501


VSM

Table 831 provides information about the system performance.

Table 831: System Performance


Deployment layer Point-to-Point protected, Ring
Switch mode Link vector controlled
Software controlled
Max. latency per pair 50 ns

Table 832 provides information about protection switching.

Table 832: Protection Switching


Protection scheme Line, band, subband, group or channel
protection switching in point to point
and ring topologies.
Switching criteria Link vector controlled via
2OSCM-V#1630, OSCM-PN

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

502 Module and System Specification


Chapter 7 Management and Switch Modules

RSM-OLM#1630
The Remote Switch Module with Optical Line Monitoring (RSM-OLM#1630) is
used to provide optical line monitoring and line protection. Pilot lasers are used
to monitor the optical lines for fiber cuts, fiber intrusion and fiber
degradation/aging. The thresholds defining fiber intrusion and signal degrade
are user configurable. Protection switching takes place in the event of LOS
(fiber break) or fiber degradation (signal degrade). As long as both network fiber
pairs are available, the non-active fiber pair can be used to transmit low priority
traffic.
Table 833 provides general information about the module and its environment.

Table 833: General Information


Equipment type RSM-OLM
First release 7.0
Width 4 HP
Height 5 HU
Weight 550 g (1.2 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Typ. power consumption 11 W


Max. power consumption 14 W
Maximum RAM consumption on 121 Kbytes
NCU
MTBF at 25°C ambient temperature 366,032 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

Table 834 provides information about the interfaces.

Table 834: Interfaces


Number of optical interfaces 5
Optical connector type MU
Fiber type SM G.652

Table 835 provides information about the optical characteristics.

Table 835: Optical Characteristics


Max. insertion loss 2.3 dB single switch
Any client port to any network port 4.6 dB as a pair
at 1463.5 nm to 1616.5 nm.
Max. insertion loss to monitor 16 dB
output
Max. latency per pair 50 ns

Module and System Specification 503


RSM-OLM#1630

Table 836 provides information about the optical line monitoring characteristics.

Table 836: Optical Line Monitoring Characteristics


Pilot laser wavelength 1630 nm
Pilot laser output power at line port -4 dBm ... 0 dBm
Pilot receiver dynamic range at -32 dBm ... 0 dBm
1630 nm
Measurement accuracy +/- 1.5 dB
Measurement range for WDM 0 dB ... 26 dB loss between 2 RSMs
budget (Input power at RSM-OLM
input < -31 dBm may result in
displaying wrong budget values.)
Switch level for fiber cut at 1630 nm < -32 dBm
Budget at 1630 nm  28 dB
(switching criteria: loss of signal)

Table 837 provides information about the application.

Table 837: Application


Deployment layer Point-to-point protected
ALS support Legacy ALS scheme for pilot laser

Table 838 provides information about fault/performance monitoring of the

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
network ports.

Table 838: Fault/Performance Monitoring Network Port


Physical layer LOS, OPR

Table 839 provides information about protection switching.

Table 839: Protection Switching


Protection scheme Line protection
Protection switching time  <15 ms
(incl. LOS detection) (Service recovery time is longer and
is stated in the respective channel
module specification.)
Signal fail switching criteria physical LOS
Signal degrade switching criteria pilot laser attenuation threshold
support of enabling/disabling
protection switching based on SD

504 Module and System Specification


Chapter 7 Management and Switch Modules

OSCM-PN
The OSCM-PN is an optical supervisory channel module with optical line
monitoring and dual pluggable optical network interfaces for east-west
applications. The pluggable network interfaces allow flexibility in the selection of
various OSC wavelengths and fiber spans. The module has an integrated
Ethernet switch and three Ethernet ports on the client side. The OSCM-PN
performs a layer-2-switching between the electrical and optical Ethernet ports.
In addition, this module integrates an optical line monitoring facility which
enables to monitor the optical lines for fiber break and fluctuations of fiber
attenuation. The optical line monitoring relies on OPR measurements.
Therefore the OLM functionality is only available when the SFP is operated
inside of the specified OPR measurement range. See specifications of SFP for
details. This module is a central component of the DCN.
The OSCM-PN can be employed for:
• providing the OSC as an integral part of the laser safety mechanisms in
Raman amplifier configurations using a wavelength of 1528.77 nm
• DCN communication in dual-fiber working configurations using an OSC
wavelength of 1510 nm
• DCN communication in single-fiber working configurations using an OSC
wavelength of 1490 nm and 1510 nm
• DCN communication (32/40ch systems only) in configuration with the
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

appropriate port of an DWDM filter (40CSM, 4CSM e.g.) using the


SFP/2G5U/#Dxxxx.xxU/SM/LC#Dxx (only C band is supported)
The OSCM-PN works only in conjunction with an appropriate OSFM or RAMAN
amplifier in both directions. The OSFMs must agree with the SFP transceivers
selected for use with the OSCM-PN.
Table 840 provides general information about the module and its environment.

Table 840: General Information


Equipment type OSCMPN
First release 8.2
Width 4 HP
Height 5 HU
Weight 500 g (1.1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Typ. power consumption 11 W
Max. power consumption 16 W
Maximum RAM consumption on 302 Kbytes
NCU

Module and System Specification 505


OSCM-PN

Table 840: General Information (Continued)


MTBF at 25°C ambient temperature 747,029 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

Table 841 provides information about the interfaces.

Table 841: Interfaces


Number of optical network 2
interfaces
Network interface type SFP
Number of electrical 3
interfaces
Electrical connector type RJ45 10/100baseTX
Cable category CAT5E
Cable type unshielded for cable length: < 3 m
shielded (S/FTP) for cable length: 3 m to 100 m
Max. link distance 100 m

Table 842 provides information about the supported network SFPs.

Table 842: Supported Network SFPs

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
1310 nm types SFP/2G5U/1310L/SM/LC (supported in
OSCM-PN with HW Rev. 3.01 or newer
only)
1490 nm types SFP/FE/C1490U/SM/LC
SFP/FE/C1490V/SM/LC
1510 nm types SFP/FE/C1510U/SM/LC
SFP/FE/C1510V/SM/LC
CWDM types SFP/2G5U/CxxxxV/SM/LC (supported in
OSCM-PN with HW Rev. 3.01 or newer
only)
DWDM types SFP/FE/D1528.77E/SM/LC
SFP/FE/Dxxxxx.xxV/SM/LC1 (supported
in OSCM-PN with HW Rev. 3.01 or newer
only)
SFP/2G5U/#Dxxxx.xxU/SM/LC#Dxx1
with HW Rev. 3.01 or newer (only C band
is supported
1. The signal from these DWDM SFPs must not pass ROADMs.

Table 843 provides information about the optical interface characteristics.

Table 843: Optical Interface Characteristics


Data rate 125 MBit/s
Frame structure Fast Ethernet

506 Module and System Specification


Chapter 7 Management and Switch Modules

Table 844 provides information about the application.

Table 844: Application


Deployment layer Point-to-point, linear add/drop and ring
topologies
Management OSC for DCN communication
Protocol support Topology detection
layer 2/3 protocols on optical ports
ALS support Legacy ALS scheme for OSC pilot laser

Table 845 provides information about fault/performance monitoring of the


network ports.

Table 845: Fault/Performance Monitoring Network Ports


Physical layer LOS, OPR
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 507


508
OSCM-PN

Module and System Specification


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Chapter 8
Reconfigurable Optical Layer Devices

This chapter describes reconfigurable optical layer devices of the FSP 3000R7.
The following sections are provided:
“ROADM-C80/0/OPM” on p. 510
“8ROADM-C40/0/OPM” on p. 516
“8ROADM-C80/0/OPM” on p. 521
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

“9ROADM-C96/0/OPM” on p. 526
“4ROADM-C96/0/OPM” on p. 532
“CCM-C40/8” on p. 537
“CCM-C80/8” on p. 541
“CCM-C96/9” on p. 545
“4-OPCM” on p. 550

Module and System Specification 509


ROADM-C80/0/OPM

ROADM-C80/0/OPM
The ROADM-C80/0/OPM is used for channel add/drop and/or optical power
control. The ROADM-C80/0/OPM also provides the ability to monitor individual
channel power levels. The ROADM-C80/0/OPM can be used in a number of
different node configurations that include Optical Terminal Multiplexer (OTM),
Reconfigurable Optical Add Drop Multiplexer (ROADM) and Line-amp. In most
applications the ROADM-C80/0/OPM modules will be used in pairs.
The ROADM-C80/0/OPM can be provisioned to handle up to 40 C-band
channels with 100 GHz channel spacing or 80 C-band channels with 50 GHz
channel spacing.
An integrated optical power monitor (OPM) in the ROADM-C80/0/OPM module
allows power balancing on a per wavelength basis at the network port.
The forward and backward fault indicators on channel module ports (controlled
by the ERRFWD and ALSMODE parameters) must not be set to disable the
optical channel. The ALSMODE parameter must be set to "None" and the
ERRFWD parameter must not be set to "Laser Off". If these parameters cannot
be set to these setting then the module should not be used when the optical
channel passes through the ROADM-C80/0/OPM.
Below is a simplified block diagram of the ROADM-C80/0/OPM.

Figure 4: ROADM-C80/0/OPM Block Diagram

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ROADM-C80/0/OPM

U-M
N-M WSS
C-M

U-D
N-D Splitter
C-D

Table 846 provides general information about the module and its environment.

Table 846: General Information


Equipment type ROADM-C80
First release 9.1
Width 8 HP
Height 5 HU
Weight 2 kg (4.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1

510 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

Table 846: General Information (Continued)


Equipment type ROADM-C80
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 231,108 h
Typ. power consumption 11 W
Max. power consumption 15 W
Maximum RAM consumption on 6,129 Kbytes
NCU
Slot positions SH9HU: 3...17
SH7HU, SH7HU-R: 3...17
NCU types All NCU, limited to 4 degrees with
first generation NCU

This table provides information about the module’s optical characteristics.

Table 847: Optical Characteristics - General


Number of client ports 1
Number of upgrade ports 1
Number of network ports 1
Number of channels per port 40 or 80 (19200 to 19595)
Channel spacing 100 GHz or 50 GHz acc. to ITU-T G.694
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Wavelength range 1529.94 nm ... 1561.42 nm


Power monitor range 3 dBm to -27 dBm
Power monitor accuracy ± 1.5 dB
Attenuation setting range 0 dB to 14 dB
Attenuation setting step 0.1 dB
Attenuation step accuracy < 0.6 dB
Optical connector type LC
Fiber type SM G.652

The following table provides information about the optical characteristics of the
network port.

Table 848: Optical Characteristics - Network Port


N-D to C-D max. insertion loss 5 dB
N-D to U-D max. insertion loss 5 dB
N-D LOS threshold -10 dBm
N-D total input power -10 dBm ... 21 dBm
N-D input per channel power -2 dBm ... 7 dBm
N-M total output power (equalized) -22 dBm ... 12 dBm
N-M output per channel power (equalized) -22 dBm ... -7 dBm
N-M isolation between inputs > 35 dB

Module and System Specification 511


ROADM-C80/0/OPM

Table 848: Optical Characteristics - Network Port


Return loss > 35 dB
Latency
N-D to C-D 32 ns
N-D to U-D 32 ns

The following table provides information about the optical characteristics of the
client ports.

Table 849: Optical Characteristics - Client Ports


C-M total input power (to equalize) -10 dBm ... 20 dBm
C-M input per channel power (to equalize) -10 dBm ... 4 dBm
C-M to N-M insertion loss max. 9.1 dB,
typ. 6.6 dB
C-M to N-M unpowered insertion loss > 40 dB
C-D total output power -7 dBm ... 20 dBm
C-D output per channel power -7 dBm ... +4 dBm
Optical return loss > 35 dB
Adjacent channel isolation > 35 dB
C-M to N-M chromatic dispersion -20 ps/nm ... +20 ps/nm
C-M to N-M passband at 3 dB 280 pm (35 GHz) for 50 GHz
channel spacing acc. to ITU-T
G.694

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
560 pm (70 GHz) for 100 GHz
channel spacing acc. to ITU-T
G.694
Latency C-M to N-M 58 ns

512 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

This table shows information about the optical characteristics of the upgrade
port.

Table 850: Optical Characteristics - Upgrade Port


U-M total input power (to equalize) -10 dBm ... 20 dBm
U-M input per channel power -10 dBm ... 4 dBm
U-M to N-M max. insertion loss max. 9.1 dB (worst case, EOL),
typ. 6.6 dB
U-D total output power -7 dBm ... 20 dBm
U-D output per channel power -7 dBm ... 4 dBm
Optical return loss > 35 dB
Adjacent channel isolation > 35 dB
U-M to N-M chromatic dispersion -20 ps/nm ... 20 ps/nm
U-M to N-M passband at 3 dB 280 pm (35 GHz) for 50 GHz
channel spacing acc. to ITU-T
G.694
560 pm (70 GHz) for 100 GHz
channel spacing acc. to ITU-T
G.694
Latency U-M to N-M 58 ns

Whether fault/performance monitoring entries listed in the


PS
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

This table shows information about fault monitoring of the module in general.

Table 851: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Total input power of all client ports too high

This table shows information about fault monitoring of the client port in general.

Table 852: Fault Monitoring Client Interface - General


Physical layer Loss of signal

This table shows information about fault monitoring of the upgrade port in
general.

Table 853: Fault Monitoring Upgrade Interface - General


Physical layer Loss of signal

Module and System Specification 513


ROADM-C80/0/OPM

This table shows information about fault monitoring of the network port in
general.

Table 854: Fault Monitoring Network Interface - General


Physical layer Loss of signal;
Optical power monitor failure

The following table shows information about fault monitoring of the virtual
channel (virtual channel representing single channel).

Table 855: Fault Monitoring Virtual Channel


Physical layer Optical power Tx signal failure;
Power block fault (when channel disabled)

The following table provides information about performance monitoring of the


module in general.

Table 856: Performance Monitoring - General


Equipment Module temperature (current value)
(Fix threshold crossing alert for module
temperature too high available)

This table shows information about performance monitoring of the client port.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 857: Performance Monitoring Client Interface - General
Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high)
values;
User configurable threshold crossing
alerts for OPR too high/too low available)

This table shows information about performance monitoring of the upgrade port.

Table 858: Performance Monitoring Upgrade Interface - General


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high)
values;
User configurable threshold crossing
alerts for OPR too high/too low available)

514 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

These tables show information about performance monitoring of the network


port.

Table 859: Performance Monitoring Network Interface - General


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high);
values; Optical power Tx (current, low,
User configurable threshold crossing mean, high)
alerts for OPR too high/too low available;
User configurable threshold crossing
alerts for OPT high/low available)

The following table shows information about performance monitoring of the


virtual channel (virtual channel representing single channel).

Table 860: Performance Monitoring Virtual Channel


Physical layer Optical power Rx (current);
(15 min/24 h records available for PM Optical power Tx (current, low,
values except current values; mean, high)
Fix threshold crossing alerts for OPT too
high/too low available)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 515


8ROADM-C40/0/OPM

8ROADM-C40/0/OPM
The 8ROADM-C40/0/OPM is an FSP 3000R7 module that functions as a
transparent Reconfigurable Optical Add Drop Multiplexer. As part of the FSP
3000R7 optical layer, the module enables nodes to support network
configurations like ring interconnections using 4 degrees or fully meshed
topologies up to 8 degrees.
The module supports the following optical channel configurations:
• Add/Drop
• Pass-through
• Drop/Continue
The 8ROADM-C40/0/OPM contains one duplex network interface (or degree)
and 8 duplex client interfaces. The received network signal is split into 8
identical copies, which are available at the client port outputs. One or two client
ports may be used for local add/drop which are followed by optical filters
(1CSM, 4CSM, 40CSM). The other client ports are connected to the client ports
of other 8ROADM-C80/0/OPM modules to support channel transmission to
different degrees. An integrated optical power monitor (OPM) in the module
allows power balancing on a per wavelength basis at the network port output.
The NCU limits the number of supported degrees (network interfaces) to four.
The NCU-II supports up to 8 degrees.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The forward and backward fault indicators on channel module ports (controlled
by the ERRFWD and ALSMODE parameters) must not be set to disable the
optical channel. The ALSMODE parameter must be set to "None" and the
ERRFWD parameter must not be set to "Laser Off" . If these parameters cannot
be set to these setting then the module should not be used when the optical
channel passes through the 8ROADM-C40/0/OPM.
Below is a simplified block diagram of the 8ROADM-C40/0/OPM.

Figure 5: 8ROADM-C40/0/OPM Block Diagram


8 ROADM-C40/0/ OPM
C1-D
C2-D
C3-D
PD 1x8 C4-D
N- D
Splitter C5-D
C6-D
C7-D
C8-D
PDs
C1- M
OPM C2- M
C3- M
8x1 C4- M
N- M
WSS C5- M
C6- M
C7- M
C8- M

516 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

Table 861 provides general information about the module and its environment.

Table 861: General Information


Equipment type 8ROADM-C40
First release 8.3
Width 12 HP
Height 5 HU
Weight 1.2 kg (2.6 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 251,837 h
Typ. power consumption 17 W
Max. power consumption 33 W
Maximum RAM consumption on 4,394 Kbytes
NCU
Slot positions SH9HU: 3 ... 16
SH7HU, SH7HU-R: 3...16
NCU types All NCU, limited to 4 degrees with
first generation NCU
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

This table provides information about the module’s optical characteristics.

Table 862: Optical Characteristics - General


Number of client ports 8
Number of network ports 1
Number of channels per port 40 (19200 to 19590)
Channel spacing 100 GHz acc. to ITU-T G.694
Wavelength range 1530.33 nm ... 1561.42 nm
N-D to C-D max. insertion loss 12.5 dB
N-M isolation between inputs > 25 dB
N-M isolation input to output > 35 dB
Power monitor range +3 dBm to -27 dBm
Power monitor accuracy ± 1.5 dB
Attenuation setting range 0 dB to 20 dB
Attenuation setting step 0.1 dB
Optical connector type LC
Fiber type SM G.652

The following table provides information about the optical characteristics of the
network port.

Table 863: Optical Characteristics - Network Port


N-D total input power 0 dBm ... 21 dBm
N-D input per channel power 0 dBm ... 7 dBm

Module and System Specification 517


8ROADM-C40/0/OPM

Table 863: Optical Characteristics - Network Port (Continued)


N-M total output power (equalized) -22 dBm ... 7 dBm
N-M output per channel power (equalized) -22 dBm ... -9 dBm
Return loss > 35 dB
N-D to C-D latency 35 ns

The following table provides information about the optical characteristics of the
client ports.

Table 864: Optical Characteristics - Client Ports


C-M total input power (to equalize) -11 dBm ... 20 dBm
C-M input per channel power (to equalize) -11 dBm ... 7 dBm
C-M to N-M max. insertion loss 7.1 dB
C-M to N-M unpowered insertion loss > 40 dB
Optical return loss > 35 dB
Adjacent channel isolation > 30 dB
C-M to N-M chromatic dispersion -20 ps/nm ... +20 ps/nm
C-M to N-M passband at 3 dB 400 pm (50 GHz)
C-M to N-M settable attenuation 0 dB ... 15 dB
C-D output per channel power -21 dBm ... -12 dBm
C-M to N-M latency 70 ns

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Whether fault/performance monitoring entries listed in the
PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

This table shows information about fault monitoring of the module in general.

Table 865: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Total input power of all client ports too high

This table shows information about fault monitoring of the client ports in general.

Table 866: Fault Monitoring Client Interface - General


Physical layer Loss of signal

518 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

This table shows information about fault monitoring of the network ports in
general.

Table 867: Fault Monitoring Network Interface - General


Physical layer Loss of signal;
Optical power monitor failure

The following table shows information about fault monitoring of the virtual
channel (virtual channel representing single channel).

Table 868: Fault Monitoring Virtual Channel


Physical layer Optical power Tx signal failure;
Power block fault (when channel disabled)

The following table provides information about performance monitoring of the


module in general.

Table 869: Performance Monitoring - General


Equipment Module temperature
(Fix threshold crossing alert for module (current value)
temperature too high available)

This table shows information about performance monitoring of the client ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 870: Performance Monitoring Client Interface - General


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high)
values except current values;
User configurable threshold crossing
alerts for OPR too high/too low available)

This table shows information about performance monitoring of the network


ports.

Table 871: Performance Monitoring Network Interface - General


Physical layer Optical input power Rx (current,
(15 min/24 h records available for PM low, mean, high);
values except current values; Optical output power Tx (current,
User configurable threshold crossing low, mean, high)
alerts for OPR too high/too low available;
Fix threshold crossing alerts for OPT too
high/too low available)

Module and System Specification 519


8ROADM-C40/0/OPM

The following table shows information about performance monitoring of the


virtual channel (virtual channel representing single channel).

Table 872: Performance Monitoring Virtual Channel


Physical layer Optical power Rx (current);
(15 min/24 h records available for PM Optical power Tx (current, low,
values except current values; mean, high)
Fix threshold crossing alerts for OPT too
high/too low available)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

520 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

8ROADM-C80/0/OPM
The 8ROADM-C80/0/OPM is an FSP 3000R7 module that functions as a
Reconfigurable Optical Add Drop Multiplexer. As part of the FSP 3000R7 optical
layer, the module enables nodes to support network configurations like ring
interconnections using 4 degrees or fully meshed topologies up to 8 degrees.
The module supports the following optical channel configurations:
• Add/Drop
• Pass-through
• Drop/Continue
The 8ROADM-C80/0/OPM contains one duplex network interface (or degree)
and 8 duplex client interfaces. The received network signal is split into 8
identical copies, which are available at the client port outputs. One or two client
ports may be used for local add/drop which are followed by optical filters
(1CSM, 4CSM, 40CSM). The other client ports are connected to client ports of
other 8ROADM-C80/0/OPM modules to support channel transmission to
different degrees. An integrated optical power monitor (OPM) in the module
allows power balancing on a per wavelength basis at the network port output.
The NCU limit the number of supported degrees (network interfaces) to four.
The NCU-II supports up to 8 degrees.
The forward and backward fault indicators on channel module ports (controlled
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

by the ERRFWD and ALSMODE parameters) must not be set to disable the
optical channel. The ALSMODE parameter must be set to "None" and the
ERRFWD parameter must not be set to "Laser Off". If these parameters cannot
be set to these setting then the module should not be used when the optical
channel passes through the 8ROADM-C80/0/OPM.
Figure 6 illustrates a simplified block diagram of the 8ROADM-C80/0/OPM.

Figure 6: 8ROADM-C80/0/OPM Block Diagram

8ROADM-C80/0/OPM
C1-D
C2-D
C3-D
PD 1x8 C4-D
N-D Splitter C5-D
C6-D
C7-D
C8-D
PDs
Switch OPM C1-M
C2-M
C3-M
8x1 C4-M
N-M
WSS C5-M
C6-M
C7-M
C8-M

Module and System Specification 521


8ROADM-C80/0/OPM

Table 873 provides general information about the module and its environment.

Table 873: General Information


Equipment type 8ROADM-C80
First release 10.1
Width 12 HP
Height 5 HU
Weight 1.2 kg (2.6 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 218,914 h
Typ. power consumption 15 W
Max. power consumption 30 W
Maximum RAM consumption on 6,806Kbytes
NCU
Slot positions SH9HU: 3 ... 16
SH7HU, SH7HU-R: 3...16
NCU types All NCU, limited to 4 degrees with
first gerneration NCU

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table provides information about the module’s optical characteristics.

Table 874: Optical Characteristics - General


Number of client ports 8
Number of network ports 1
Number of channels per port 80 (19200 to 19595)
Channel spacing 50 GHz acc. to ITU-T G.694
Wavelength range 1529.94 nm ... 1561.42 nm
N-D to C-D max. insertion loss 12.4 dB
C-M to N-M min. insertion loss 2.6 dB
C-M to N-M max. insertion loss 7.8 dB
C-M to N-M unpowered insertion loss 40 dB
Adjacent channel isolation 35 dB
C-M to N-M optical isolation between >25 dB
input ports
Max. non-uniformity between all 7 dB
received C port channels
N-M channel power monitor range 3 dBm to -27 dBm
N-D channel power monitor range 10 dBm to -20 dBm
N-D total power monitor range 23 dBm to -10 dBm
C-M total power monitor range 20 dBm to -20 dBm
Power monitor accuracy ± 1.5 dB
Attenuation setting range 0 dB to 20 dB
Attenuation setting step 0.1 dB
Attenuation step accuracy < 0.2 dB

522 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

Table 874: Optical Characteristics - General (Continued)


Optical connector type LC
Fiber type SM G.652

The following table provides information about the optical characteristics of the
network port.

Table 875: Optical Characteristics - Network Port


Channel block bandwidth > 20 GHz
Optical return loss > 35 dB
N-D total input power -2 dBm ... 21 dBm
N-D input per channel power -2 dBm ... 4 dBm
N-M total output power (to equalize) -24 dBm ... 10 dBm
N-M output per channel power (to equalize) -24 dBm ... -9 dBm
Return loss > 35 dBm
Max. non-uniformity between received 6 dB
channels
N-D to C-D latency 35 ns

The following table provides information about the optical characteristics of the
client ports.

Table 876: Optical Characteristics - Client Ports


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Optical return loss > 35 dB


C-M total input power (to equalize) -15 dBm ... 14 dBm
C-M input per channel power (to equalize) -15 dBm ... -4 dBm
C-D total output power -14 dBm ... 14 dBm
C-D output per channel power -21 dBm ... -12 dBm
Max. non-uniformity between received 7 dB
channels
Max. channel input power before damage 11 dBm
Max. total input power all C ports before 26 dBm
damage
C-M to N-M passband at 3 dB 256 pm (32 GHz)
C-M to N-M latency 52 ns

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

Module and System Specification 523


8ROADM-C80/0/OPM

This table shows information about fault monitoring of the module in general.

Table 877: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Total input power of all client ports too high

This table shows information about fault monitoring of the client ports in general.

Table 878: Fault Monitoring Client Interface - General


Physical layer Loss of signal

This table shows information about fault monitoring of the network ports in
general.

Table 879: Fault Monitoring Network Interface - General


Physical layer Loss of signal;
Optical power monitor failure

The following table shows information about fault monitoring of the virtual

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
channel (virtual channel representing single channel).

Table 880: Fault Monitoring Virtual Channel


Physical layer Optical power Tx signal failure;
Power block fault (when channel disabled)

The following table provides information about performance monitoring of the


module in general.

Table 881: Performance Monitoring - General


Equipment Module temperature
(Fix threshold crossing alert for module (current value)
temperature too high available)

This table shows information about performance monitoring of the client ports.

Table 882: Performance Monitoring Client Interface - General


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high)
values except current values;
User configurable threshold crossing
alerts for OPR too high/too low available)

524 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

This table shows information about performance monitoring of the network


ports.

Table 883: Performance Monitoring Network Interface - General


Physical layer Optical input power Rx (current,
(15 min/24 h records available for PM low, mean, high);
values except current values; Optical output power Tx (current,
User configurable threshold crossing low, mean, high)
alerts for OPR too high/too low available;
Fix threshold crossing alerts for OPT too
high/too low available)

The following table shows information about performance monitoring of the


virtual channel (virtual channel representing single channel).

Table 884: Performance Monitoring Virtual Channel


Physical layer Optical power Rx (current);
(15 min/24 h records available for PM Optical power Tx (current, low,
values except current values; mean, high)
Fix threshold crossing alerts for OPT too
high/too low available)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 525


9ROADM-C96/0/OPM

9ROADM-C96/0/OPM
The 9ROADM-C96/0/OPM is an FSP 3000R7 module that functions as a Net-
work wavelength switching point. The 9ROADM-C96/0/OPM module can be
deployed alongside existing FSP 3000R7 modules in an FSP 3000R7 Network
Element (NE). The 9ROADM-C96/0/OPM operates with the NCU-II and
NCU-II-P which support up to 9 degrees (network interfaces) for add-drop appli-
cations or 10 degrees for tandem switch applications.
An FSP 3000R7 NE containing 9ROADM-C96/0/OPM modules supports linear,
ring, ring interconnect, and mesh network configurations.The
9ROADM-C96/0/OPM module enables provisioning and adjustment of add-drop
and pass-through DWDM C-band channels and supports these optical connec-
tion configurations:
• Add-drop
• Pass-through
• Add
• Drop
The 9ROADM-C96/0/OPM module can handle 96 C-band channels with 50
GHz spacing. It contains one duplex network interface and 9 duplex Client inter-
faces. The N-C path (N-R to Cx-T) signal is split into 9 identical copies, which
are available on the module front panel at the Cx-T outputs. For local drop con-
nections, one or two of these C-band outputs are typically used, and the others

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
are routed to additional 9ROADM-C96/0/OPM modules in the node for transmis-
sion to one or more degrees.
The C-N path (Cx-R to N-T) allows selection of up to 96 different C-band chan-
nels from the Cx-R inputs for transmission on the N-T output. Typically, the
Cx-R inputs are connected from the other 9ROADM-C96/0/OPM modules and
the local add connections. The add and drop connections are connected to opti-
cal filters or any add-drop Fixed or Directionless structure associated with that
degree.
The 9ROADM-C96/0/OPM also has improved transient control, allowing for bet-
ter regulation of variations in channel amplitudes.
Figure 7 illustrates a simplified block diagram of the 9ROADM-C96/0/OPM.

526 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

Figure 7: 9ROADM-C96/0/OPM Block Diagram


9ROADM-C96/0/OPM C1-T
C2-T
C3-T
C4-T

1x9 Splitter
PD PD
N-R C5-T
Amplifer
C6-T
C7-T
C8-T
C9-T

Network Fiber Detection Fiber Detection Client


Interface Circuit Circuit Interfaces

PDs
Switch C1-R
C2-R
C3-R
OCM C4-R
PD

9x1 WSS
N-T C5-R
C6-R
C7-R
C8-R
C9-R

Table 885 provides general information about the module and its environment.

Table 885: General Information


Equipment type 9ROADM-C96
First release 11.2
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Width 16 HP
Height 5 HU
Weight 3200g (7.054lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 150,000 h
Typ. power consumption 55 W
Max. power consumption 90 W
Slot positions SH9HU: 3 ... 15
NCU types NCU-II and NCU-II-P

This table provides information about the module’s optical characteristics.

Table 886: Optical Characteristics - General


Number of client ports 9
Number of network ports 1
Number of channels per port 96 (191.25 THz to196.00 THz)
Channel spacing 50GHz
Wavelength range 1529 nm ... 1568 nm
Cx-R to N-T min. insertion loss 4.0 dB
Cx-R to N-T max. insertion loss 9.5 dB

Module and System Specification 527


9ROADM-C96/0/OPM

Table 886: Optical Characteristics - General (Continued)


Cx-R to N-T unpowered insertion 40 dB
loss
Cx-R to N-R passband at 3 dB 35 GHz
Adjacent channel isolation 35 dB
Power monitor accuracy ± 1.0 dB total power (EOL), ± 1.2 dB
channel power (EOL)
Set point range -15 dB to -21 dB
Optical connector type LC
Fiber type SM G.652
N-R to Cx-T latency 310 ns
Cx-R to N-T latency 90 ns
Gain N-R to Cx-T 6 dB to 16 dB (adjustable)

The following table provides information about the optical characteristics of the
network port.

Table 887: Optical Characteristics - Network Port


Channel block bandwidth > 10 GHz
Optical return loss > 35 dB
N-R total input power -24 dBm ... 10 dBm
N-R input per channel power -24 dBm ... -7 dBm
N-T total output power (equalized) -24 dBm ... 9 dBm

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
N-T output per channel power (equalized) -24 dBm ... -12 dBm
Max. non-uniformity between received 7 dB
channels

The following table provides information about the optical characteristics of the
client ports.

Table 888: Optical Characteristics - Client Ports


Optical return loss > 35 dB
Cx-R total input power -15 dBm ... 20 dBm
Cx-R input per channel power -15 dBm ... 0 dBm
Cx-T total output power -10 dBm ... 20 dBm
Cx-T output per channel power -10 dBm ... 0 dBm
Maximum total power before damage to all 26 dBm
ports
Maximum channel power before damage 12 dBm
Max. non-uniformity between received 9 dB
channels

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

528 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

This table shows information about fault monitoring of the module in general.

Table 889: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
OPM fail;
General hardware fault;
Hardware abnormal;
Hardware initializing;
Firmware package mismatch NSA;
Firmware package mismatch SA;

This table shows information about fault monitoring of the client ports in general.

Table 890: Fault Monitoring Client Interface - General


Physical layer Loss of signal;
Optical power Tx signal failure

This table shows information about fault monitoring of the network ports in gen-
eral.

Table 891: Fault Monitoring Network Interface - General


Physical layer Loss of signal;
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Power block fault (total power);


Optical power Tx signal failure

The following table shows information about fault monitoring of the virtual chan-
nel (virtual channel representing single channel).

Table 892: Fault Monitoring Virtual Channel at Network Port Output


Physical layer Optical power Tx signal failure;
Power block fault (when channel disabled)

The following table shows information about fault monitoring of the EDFA sub-
module.

Table 893: Fault Monitoring EDFA Submodule


EDFA Submodule Auto shutdown high temperature;
Optical power Tx limit;
Laser - Current Abnormal;
Laser - End of life

Module and System Specification 529


9ROADM-C96/0/OPM

The following table provides information about performance monitoring of the


module in general.

Table 894: Performance Monitoring - General


Equipment Module temperature
(Fix threshold crossing alert for module (current)
temperature high is available)

This table shows information about performance monitoring of the client ports.

Table 895: Performance Monitoring Client Interface - General


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high)
values except current values; Optical power Tx (current, low,
User configurable threshold crossing mean, high)
alerts for Optical Power Rx high/low are
available)

This table shows information about performance monitoring of the network


ports.

Table 896: Performance Monitoring Network Interface - General


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
values except current values; Optical power Tx (current, low,
User configurable threshold crossing mean, high)
alerts for Optical Power Rx high/low are
available;
Fix threshold crossing alerts for Optical
Power Tx high/low are available)

The following table shows information about performance monitoring of the vir-
tual channel (virtual channel representing single channel).

Table 897: Performance Monitoring Virtual Channel at Network Port


Physical layer Optical power Rx (current)
(15 min/24 h records available for PM Optical power Tx (current, low,
values except current values; mean, high)
Fix threshold crossing alerts for Optical
Power Tx high/low are available)

This table shows information about performance monitoring of the virtual chan-
nel at client port.

Table 898: Performance Monitoring Virtual Channel at Client Port


Physical layer Optical power Rx (current)

530 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

The following table shows information about performance monitoring of the


EDFA Submodule.

Table 899: Performance Monitoring EDFA Submodule


EDFA Submodule Operating hours
(Fix threshold crossing alerts for Temperature
Pump lasers 1, 2, and 3 Optical power Tx (current)
temperature high/low and Pump lasers 1, 2, and 3 bias current
submodule temperature high are (current)
available) Pump lasers 1, 2, and 3 temperature
(current)
Defect Seconds (current)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 531


4ROADM-C96/0/OPM

4ROADM-C96/0/OPM
The 4ROADM-C96/0/OPM is an FSP 3000R7 module that functions as a Net-
work wavelength switching point. The 4ROADM-C96/0/OPM module can be
deployed alongside existing FSP 3000R7 modules in an FSP 3000R7 Network
Element (NE). The 4ROADM-C96/0/OPM operates with the NCU-II and
NCU-II-P which support up to 4 degrees (network interfaces) for add-drop appli-
cations or 5 degrees for tandem switch applications.
An FSP 3000R7 NE containing 4ROADM-C96/0/OPM modules supports linear,
ring, ring interconnect, and mesh network configurations.The
4ROADM-C96/0/OPM module enables provisioning and adjustment of add-drop
and pass-through DWDM C-band channels and supports these optical connec-
tion configurations:
• Add-drop
• Pass-through
• Add
• Drop
The 4ROADM-C96/0/OPM module can handle 96 C-band channels with 50
GHz spacing. It contains one duplex network interface and 4 duplex Client inter-
faces. The N-C path (N-R to Cx-T) signal is split into 4 identical copies, which
are available on the module front panel at the Cx-T outputs. For local drop con-
nections, one or two of these C-band outputs are typically used, and the others

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
are routed to additional 4ROADM-C96/0/OPM modules in the node for transmis-
sion to one or more degrees.
The C-N path (Cx-R to N-T) allows selection of up to 96 different C-band chan-
nels from the Cx-R inputs for transmission on the N-T output. Typically, the
Cx-R inputs are connected from the other 4ROADM-C96/0/OPM modules and
the local add connections. The add and drop connections are connected to opti-
cal filters or any add-drop Fixed or Directionless structure associated with that
degree.
Figure 7 illustrates a simplified block diagram of the 4ROADM-C96/0/OPM.

532 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

Figure 8: 4ROADM-C96/0/OPM Block Diagram

4ROADM -C96/0/OPM Module

C1-T

1x4 Splitter
C2-T
N-R
C3-T
C4-T

Network WSS Component with PD Array Client


Interface Integrated 2: 1 Optical Switch Interfaces
and OCM

2:1 Switch
OCM C1-R
C2-R

4x1 WSS
N-T
C3-R
C4-R

Table 885 provides general information about the module and its environment.

Table 900: General Information


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Equipment type 4ROADM-C96


First release 12.1
Width 8 HP
Height 5 HU
Weight 1800g (3.968lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 716,906 h
Typ. power consumption 9W
Max. power consumption 12 W
Slot positions SH9HU: 3... 17, SH7HU: 1... 19
NCU types NCU-II and NCU-II-P

This table provides information about the module’s optical characteristics.

Table 901: Optical Characteristics - General


Number of client ports 4
Number of network ports 1
Number of channels per port 96 (191.25 THz to196.00 THz)
Channel spacing 50GHz/100GHz/Flex acc. to ITU-T
G.694

Module and System Specification 533


4ROADM-C96/0/OPM

Table 901: Optical Characteristics - General (Continued)


Wavelength range 1529 nm ... 1568 nm
C-R to N-T min. insertion loss 8.0 dB
C-R to N-T max. insertion loss 11.0 dB
C-R to N-T unpowered insertion loss 40 dB
C-R to N-R passband at 3 dB 17.0 GHz)
N-R to C-T min. insertion loss 6.0dB
N-R to C-T max. insertion loss 7.5dB
Adjacent channel isolation 35 dB
Power monitor accuracy ± 1.0 dB total power (EOL), ± 1.2 dB
channel power (EOL)
Set point range -12 dB to -21dB
Optical connector type LC
Fiber type SM G.652

The following table provides information about the optical characteristics of the
network port.

Table 902: Optical Characteristics - Network Port


Channel block bandwidth 25 GHz at 30 dB
Optical return loss > 35 dB
N-R total input power -6 dBm ... 21 dBm
N-R input per channel power -6 dBm ... 7 dBm

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
N-T total output power (to equalize) -24 dBm ... 11 dBm
N-T output per channel power (to equalize) -24 dBm ... -9 dBm
Max. non-uniformity between received 8.0 dB
channels

The following table provides information about the optical characteristics of the
client ports.

Table 903: Optical Characteristics - Client Ports


Optical return loss > 35 dB
C-R total input power -13 dBm ... 21 dBm
C-R input per channel power -13 dBm ... 1 dBm
C-T total output power -13 dBm ... 15 dBm
C-T output per channel power -13 dBm ... 1 dBm
Maximum non-uniformity between 10 dB
received channels
Maximum total power before damage 24 dBm
Maximum channel power before damage 12 dBm

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

534 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

This table shows information about fault monitoring of the module in general.

Table 904: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
TEMP
OPM-FLT
General hardware fault;
Hardware abnormal;
Hardware initializing;
Firmware package mismatch NSA;
Firmware package mismatch SA;

This table shows information about fault monitoring of the client ports in general.

Table 905: Fault Monitoring Client Interface - General


Physical layer Loss of signal

This table shows information about fault monitoring of the network ports in gen-
eral.

Table 906: Fault Monitoring Network Interface - General


Physical layer Loss of signal; Power block fault (total
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

power); Optical power Tx signal failure

The following table shows information about fault monitoring of the virtual chan-
nel (virtual channel representing single channel).

Table 907: Fault Monitoring Virtual Channel at Network Port Output


Physical layer Optical power Tx signal failure;
Power block fault (when channel disabled)

The following table provides information about performance monitoring of the


module in general.

Table 908: Performance Monitoring - General


Equipment Module temperature
(Fix threshold crossing alert for module (current value)
temperature too high available)

This table shows information about performance monitoring of the client ports.

Table 909: Performance Monitoring Client Interface - General


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high);
values except current values; Optical power Tx (current, low,
User configurable threshold crossing mean, high)
alerts for OPR too high/too low available)

Module and System Specification 535


4ROADM-C96/0/OPM

This table shows information about performance monitoring of the network


ports.

Table 910: Performance Monitoring Network Interface - General


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high);
values except current values; Optical power Tx (current, low,
User configurable threshold crossing mean, high)
alerts for OPR too high/too low available;
Fix threshold crossing alerts for OPT too
high/too low available)

The following table shows information about performance monitoring of the vir-
tual channel (virtual channel representing single channel).

Table 911: Performance Monitoring Virtual Channel at Network Port


Physical layer Optical power Rx (current) on
(15 min/24 h records available for PM demand;
values except current values; Optical power Tx (current, low,
Fix threshold crossing alerts for OPT too mean, high)
high/too low available)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

536 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

CCM-C40/8
The CCM-C40/8 (8-port Colorless Channel Module) is an 8 port reconfigurable
filter that allows any wavelength in the 40 channel multiplex to be dropped or
added at a node without changing any hardware. In the de-multiplex path the
CCM-C40/8 connects one channel from the optical multiplex of up to 40
channels on the network port to one of the 8 client ports. In the multiplex path
the module takes the input from all 8 client ports and optically combines them
into an optical multiplex of up to 40 channels and connects them to the network
port.
CCM modules require optical channel power to be present for proper operation.
Therefore, channel modules with channels that pass through these modules
must be set as follows:
· Auto Laser Shutdown must be set to Disable.
· Error Forwarding Mode must not be set to Laser Off.
These parameters can cause the channel module laser to be turned off. If these
parameters cannot be set to the specified setting then the module should not be
used when the optical channel passes through the CCM-C40/8.
Below is a simplified block diagram of the CCM-C40/8.

Figure 9: CCM-C40/8 Block Diagram


CCM-C40/8
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

C1-M
C2-M
C3-M
C4-M
N-M Combiner
C5-M
C6-M
C7-M
C8-M

C1-D
C2-D
C3-D
N-D WSS C4-D
C5-D
C6-D
C7-D
C8-D

Table 912 provides general information about the module and its environment.

Table 912: General Information


Equipment type 8CCM-C40
First release 9.2
Width 12 HP
Height 5 HU
Weight 1.2 kg (2.6 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.

Module and System Specification 537


CCM-C40/8

Table 912: General Information


Equipment type 8CCM-C40
MTBF at 25°C ambient temperature 300,937 h
Typ. power consumption 10 W
Max. power consumption 15 W
Slot positions SH9HU: 3 ... 16
SH7HU, SH7HU-R: 3...16
NCU types All NCU

This table provides information about the module’s optical characteristics.

Table 913: Optical Characteristics - General


Number of client ports 8
Number of network ports 1
Number of channels per port 40 (19200 to 19590)
Channel spacing 100 GHz acc. to ITU-T G.694
Wavelength range 1530.33 nm ... 1561.42 nm
Optical connector type LC
Fiber type SM G.652

The following table provides information about the optical characteristics of the
network port.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 914: Optical Characteristics - Network Port
N-M total output power -25 dBm ... 14 dBm
N-M output per channel power -25 dBm ... -2 dBm
N-D total input power -10 dBm ... 21 dBm
N-D input per channel power -10 dBm ... 7 dBm
N-D max non-uniformity between channels 9 dB
N-D to C-D unpowered insertion loss > 40 dB
Return loss > 35 dB
N-D to C-D passband at 3 dB 400 pm (50 GHz)
N-D to C-D latency 62 ns

Table below provides information about the optical characteristics of the client
ports.

Table 915: Optical Characteristics - Client Ports


C-M total input power -3 dBm ... 20 dBm
C-M input per channel power -3 dBm ... 7 dBm
C-M max non-uniformity between 9 dB
channels/ports
C-M to N-M insertion loss max. 11.6 dB, typ. 10.5 dB
C-D total output power -21 dBm ... 20 dBm
C-D output per channel power -20 dBm ... -5 dBm
N-D to C-D max insertion loss 6.8 dB
C-D port isolation > 35 dB

538 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

Table 915: Optical Characteristics - Client Ports (Continued)


Return loss > 35 dB
C-M to N-M latency 30 ns

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

This table shows information about fault monitoring of the module in general.

Table 916: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Total input power of all client ports too high

This table shows information about fault monitoring of the client ports in general.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 917: Fault Monitoring Client Interface - General


Physical layer Loss of signal;
Optical power Tx signal failure;
Power block fault (when channel disabled)

This table shows information about fault monitoring of the network ports in
general.

Table 918: Fault Monitoring Network Interface - General


Physical layer Optical power Tx signal failure

The following table provides information about performance monitoring of the


module in general.

Table 919: Performance Monitoring - General


Equipment Module temperature (current value)
(Fix threshold crossing alert for module
temperature too high available)

Module and System Specification 539


CCM-C40/8

This table shows information about performance monitoring of the client ports.

Table 920: Performance Monitoring Client Interface - General


Physical layer Optical power Tx (current, low,
(15 min/24 h records available for PM mean, high)
values except current values;
User configurable threshold crossing
alerts for OPT too high/too low available)

This table shows information about performance monitoring of the network


ports.

Table 921: Performance Monitoring Network Interface - General


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high);
values except current values; Optical power Tx (current, low,
User configurable threshold crossing mean, high)
alerts for OPR too high/too low available;
Fix threshold crossing alerts for OPT too
high/too low available)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

540 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

CCM-C80/8
The CCM-C80/8 (8-port Colorless Channel Module) is an 8 port reconfigurable
filter that allows any wavelength in the 80 channel multiplex to be dropped or
added at a node without changing any hardware. In the de-multiplex path the
CCM-C80/8 connects one channel from the optical multiplex of up to 80
channels on the network port to one of the 8 client ports. In the multiplex path
the module takes the input from all 8 client ports and optically combines them
into an optical multiplex of up to 80 channels and connects them to the network
port.
CCM modules require optical channel power to be present for proper operation.
Therefore, channel modules with channels that pass through these modules
must be set as follows:
· Auto Laser Shutdown must be set to Disable.
· Error Forwarding Mode must not be set to Laser Off.
These parameters can cause the channel module laser to be turned off. If these
parameters cannot be set to the specified setting then the module should not be
used when the optical channel passes through the CCM-C80/8.
Below is a simplified block diagram of the CCM-C80/8.

Figure 10: CCM-C80/8 Block Diagram


CCM-C80/8
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

C1-M
C2-M
C3-M
PD 8x1 C4-M
N-M
Combiner C5-M
C6-M
C7-M
C8-M
PDs
C1-D
C2-D
C3-D
PD 1x8 C4-D
N-D
WSS C5-D
C6-D
C7-D
C8-D

Table 922 provides general information about the module and its environment.

Table 922: General Information


Equipment type 8CCM-C80
First release 10.2
Width 12 HP
Height 5 HU
Weight 1.2 kg (2.6 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1

Module and System Specification 541


CCM-C80/8

Table 922: General Information


Equipment type 8CCM-C80
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 390,569 h
Typ. power consumption 15 W
Max. power consumption 20 W
Maximum RAM consumption on 263 Kbytes
NCU
Slot positions SH9HU: 3 ... 16
SH7HU, SH7HU-R: 3...16
NCU types All NCU

This table provides information about the module’s optical characteristics.

Table 923: Optical Characteristics - General


Number of client ports 8
Number of network ports 1
Number of channels per port 80 (19200 to 19595)
Channel spacing 50 GHz
Wavelength range 1529 nm ... 1562 nm
Optical connector type LC
Fiber type SM G.652

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table provides information about the optical characteristics of the
network port.

Table 924: Optical Characteristics - Network Port


N-M total output power -25 dBm ... 14 dBm
N-M output per channel power -25 dBm ... -2 dBm
N-D total input power -10 dBm ... 21 dBm
N-D input per channel power -10 dBm ... 7 dBm
N-D max non-uniformity between channels 9 dB
N-D to C-D unpowered insertion loss > 40 dB
Return loss > 35 dB
N-D to C-D passband at 3 dB 256 pm (32 GHz)
N-D to C-D latency 57 ns

Table below provides information about the optical characteristics of the client
ports.

Table 925: Optical Characteristics - Client Ports


C-M total input power -3 dBm ... 20 dBm
C-M input per channel power -3 dBm ... 7 dBm
C-M max non-uniformity between 9 dB
channels/ports
C-M to N-M insertion loss max. 11.6 dB,
typ. 10.5 dB

542 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

Table 925: Optical Characteristics - Client Ports (Continued)


C-D total output power -21 dBm ... 20 dBm
C-D output per channel power -14 dBm ... -8 dBm
N-D to C-D max insertion loss 6.8 dB
C-D port isolation > 35 dB
Return loss > 35 dB
C-M to N-M latency 30 ns

Whether fault/performance monitoring entries listed in the


PS

following tables are applicable for a specific deployment depends


on the configuration of the respective interface.
Note

This table shows information about fault monitoring of the module in general.

Table 926: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Total input power of all client ports too high

This table shows information about fault monitoring of the client ports in general.

Table 927: Fault Monitoring Client Interface - General


Physical layer Loss of signal;
Optical power Tx signal failure
Power block fault (when channel disabled)

This table shows information about fault monitoring of the network ports in
general.

Table 928: Fault Monitoring Network Interface - General


Physical layer Optical power Tx signal failure

The following table provides information about performance monitoring of the


module in general.

Table 929: Performance Monitoring - General


Equipment Module temperature (current value)
(Fix threshold crossing alert for module
temperature too high available)

Module and System Specification 543


CCM-C80/8

This table shows information about performance monitoring of the client ports.

Table 930: Performance Monitoring Client Interface - General


Physical layer Optical power Tx (current, low,
(15 min/24 h records available for PM mean, high)
values except current values;
User configurable threshold crossing
alerts for OPT too high/too low available)

This table shows information about performance monitoring of the network


ports.

Table 931: Performance Monitoring Network Interface - General


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high);
values except current values; Optical power Tx (current, low,
User configurable threshold crossing mean, high)
alerts for OPR too high/too low available;
Fix threshold crossing alerts for OPT too
high/too low available)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

544 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

CCM-C96/9

The CCM-C96/9 (9-port Colorless Channel Module) is a 9 port reconfigurable


filter that allows wavelengths to be dropped or added at a node without
changing equipment. In the drop path the CCM-C96/9 connects one channel
from the network port to one of the 9 client ports. In the add path the module
takes the input channels from all 9 client ports and combines them and connects
them to the network port.
CCM modules require optical channel power to be present for proper operation.
Therefore, channel modules with channels that pass through these modules
must be set as follows:
· Auto Laser Shutdown must be set to Disable.
· Error Forwarding Mode must not be set to Laser Off.
These parameters can cause the channel module laser to be turned off. If these
parameters cannot be set to the specified setting then the module should not be
used when the optical channel passes through the CCM-C96/9.
The figure below is a simplified block diagram of the CCM-C96/9.

Figure 11: CCM-C96/9 Block Diagram

CCM‐C96/9
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

C1-T

C2-T

C3-T
Amplifier Sub
- assembly
C4-T
9x1 WSS

N-R C5-T
Pre-
Amp C6-T

C7-T
PD PD
C8-T

C9-T

PD Array

Network Fiber Detection Client


Interface Circuit Interfaces

12x 1 Switch C1-R

C2-R

C3-R
OCM
C4-R
Combiner

N-T C5-R
1x9

C6-R

C7-R
PD
C8-R

Power C9-R
UCM
Supply /
Microprocessor
Distribution

Module and System Specification 545


CCM-C96/9

This table provides general information about the module and its environment.

Table 932: General Information


Equipment type CCM-C96/9
First release 12.3
Width 16 HP
Height 5 HU
Weight 3.2 kg (7.0 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 214,220 h
Typ. power consumption 55 W
Max. power consumption 90 W
Slot positions SH9HU: 3... 15
NCU types NCU-II, NCU-II-P

This table provides information about the module’s optical characteristics.

Table 933: Optical Characteristics - General


Number of client ports 9
Number of network ports 1

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Number of channels per port 96 (19125 to 19600)
Channel spacing 50 GHz
Wavelength range 1529 nm ... 1568 nm
Optical connector type LC
Fiber type SM G.652

This table provides information about the optical characteristics of the network
port.

Table 934: Optical Characteristics - Network Port


N-T total output power -25 dBm ... 21 dBm
N-T output per channel power -25 dBm ... 1 dBm
N-R total input power -25 dBm ... 10 dBm
N-R input per channel power -25 dBm ... -10 dBm
N-R max non-uniformity between channels 6 dB
N-R to C-T unpowered insertion loss > 40 dB
Return loss > 35 dB
N-R to C-T passband at 3 dB 256 pm (32 GHz)
N-R to C-T latency 334 ns

546 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

This table provides information about the optical characteristics of the client
ports.

Table 935: Optical Characteristics - Client Ports


C-R total input power -12 dBm ... 20 dBm
C-R input per channel power -12 dBm ... 7 dBm
C-R max non-uniformity between 8 dB
channels/ports
C-R to N-T insertion loss 9.8 dB ... 12.9 dB
C-T total output power -12 dBm ... 21 dBm
C-T output per channel power -12 dBm ... 1 dBm
C-T port isolation > 35 dB
Return loss > 35 dB
C-R to N-T latency 51 ns

This table shows information about fault monitoring of the module in general.

Table 936: Fault Monitoring - General


Equipment Module unequipped;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

This table shows information about fault monitoring of the client ports in general.

Table 937: Fault Monitoring Client Interface - General


Physical layer Loss of signal;
Amplifier outage;
N port outage

This table shows information about fault monitoring of the network ports in
general.

Table 938: Fault Monitoring Network Interface - General


Physical layer Loss of signal;
C port outage

This table shows information about fault monitoring of the virtual channel at the
network port.

Table 939: Fault Monitoring Virtual Channel at Network Port


Physical layer Loss of signal;
Server signal fail

Module and System Specification 547


CCM-C96/9

The following table shows information about fault monitoring of the EDFA sub-
module.

Table 940: Fault Monitoring EDFA Submodule


EDFA Submodule Auto shutdown high temperature;
Optical Power Tx Limit;
Laser - Current Abnormal;
Laser - End of Life

This table provides information about performance monitoring of the module in


general.

Table 941: Performance Monitoring - General


Equipment Module temperature (current)
(Fix threshold crossing alert for module
temperature high is available)

This table shows information about performance monitoring of the client ports.

Table 942: Performance Monitoring Client Interface - General


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high);
values except current values; Optical power Tx (current)
User configurable threshold crossing

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
alerts for OPR High/Low are available)

This table shows information about performance monitoring of the network


ports.

Table 943: Performance Monitoring Network Interface - General


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high);
values except current values; Optical power Tx (current, low,
User configurable threshold crossing mean, high)
alerts for Optical Power Rx High/Low and
Optical Power Tx High/Low are available)

This table shows information about performance monitoring of the virtual chan-
nel at the client port.

Table 944: Performance Monitoring Virtual Channel at Client Port


Physical layer Optical power Tx (current)

548 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

This table shows information about performance monitoring of the virtual chan-
nel at the network port.

Table 945: Performance Monitoring Virtual Channel at Network Port


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high);
values except current values; Optical power Tx (current)
User configurable threshold crossing alerts
for Optical Power Rx High/Low are
available)

The following table shows information about performance monitoring of the


EDFA Submodule.

Table 946: Performance Monitoring EDFA Submodule


EDFA Submodule Operating hours
(Fix threshold crossing alerts for Temperature
Pump lasers 1, 2, and 3 Optical power Tx (current)
temperature high/low and Optical power per channel Tx average
submodule temperature high are (current)
available) Pump lasers 1, 2, and 3 bias current
(current)
Pump lasers 1, 2, and 3 temperature
(current)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Defect Seconds (current)


Effective gain (current)

Module and System Specification 549


4-OPCM

4-OPCM
The 4-OPCM (Optical Power Control Module) is a single-slot plug-in module
with 4 optical network interfaces. Each network port features an individually
controllable variable optical attenuator (VOA) and an optical power monitor. The
4-OPCM is intended to be used as a replacement for pluggable fixed
attenuators for optical power balancing or optical power control purposes. The
4-OPCM has two different operation modes, constant attenuation mode (CA)
and constant output power mode (CP).
All provisioned parameters controlling the function of the 4-OPCM (e.g.
operational mode for each VOA, set attenuation, set output power, etc.) will be
stored persistently on the module.
Table 947 provides general information about the 4-OPCM and its environment.

Table 947: General Information


Equipment type 4OPCM
First release 8.2
Width 4 HP
Height 5 HU
Weight 600 g (1.3 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Typ. power consumption 1.7 W
Max. power consumption 3W
Maximum RAM consumption on 82 Kbytes
NCU
MTBF at 25°C ambient temperature 1,198,977 h
Slot positions SH9HU: 3 ... 18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types All NCU
Max. latency 0.05 µs

The following table contains information about the interfaces.

Table 948: Interfaces


Optical connector type LC
Number of network ports 4 unidirectional network interfaces

550 Module and System Specification


Chapter 8 Reconfigurable Optical Layer Devices

This table provides information about the optical characteristics.

Table 949: Optical Characteristics


Number of VOAs 4
Operating wavelength range 1529 nm ... 1562 nm
1569 nm ... 1604 nm
Max. input power + 23 dBm
Insertion loss at 0 dB attenuation setting 1.5 dB (C band)
1.7 dB (L band)
Attenuation setting accuracy
at < 5 dB ± 0.5 dB
at > 5 dB + 10% of target attenuation in dB
Wavelength dependent loss
at attenuation < 10 dB 0.8 dB (C band), 1 dB (L band)
at attenuation < 20 dB 1.8 dB (C band), 2.2 dB (L band)
Polarization dependent loss
at attenuation < 10 dB 0.35 dB
at attenuation < 20 dB 0.45 dB
Temperature dependent loss 0.05 dB/K
Return loss 40 dB
Isolation 60 dB
Power monitor range -30 dBm ... +13 dBm
Power monitor accuracy (in CA mode) ± 1 dB at -30 dBm ... +5 dBm
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

± 2 dB at +5 dBm ...+13 dBm


Attenuation setting range 0 dB ... 30 dB
Attenuation setting step 0.1 dB
Output power setting step (in CP mode) 0.1 dB
Output power setting accuracy ± 0.9 dB
(in CP mode)
Output power monitoring accuracy ± 1.2 dB
(in CP mode)
Response time (0.5 dB step) 50 ms
Fiber type SM G.652

Module and System Specification 551


552
4-OPCM

Module and System Specification


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Chapter 9

Optical Filter Modules


This chapter describes optical filter modules of the FSP 3000R7.
The descriptions of the discontinued optical filter modules can be found in a
former version of the FSP 3000R7 Module and System Specification.
The following sections are provided:
“ILM50-#DC” on p. 555
“2CLSM-#D01-#D64” on p. 557
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

“40CSM/2HU-#Dxx-#Dyy” on p. 558
“40CSM/2HU-#19590-#19200” on p. 560
“40CSM/2HU-#19595-#19205” on p. 562
“40CSM-FL/2HU-#19590-#19200” on p. 564
“40CSM-C80/2HU-#19xxx-#19yyy” on p. 566
“40CSM/P-2HU#19590-#19200-DM” on p. 568
“96CSM/4HU-#19600-#19125” on p. 570
“2BSM-#D01-#D32” on p. 572
“4GSM-#Dxx-#Dyy” on p. 574
“8GSM-#D01-#D32” on p. 576
“1GSM+#Dxx-#Dyy” on p. 578
“5GSM-#19590-#19200” on p. 580
“8CSM-#19xxx-#19yyy” on p. 582
“4CSM+#19xxx-#19yyy” on p. 585
“4CSM-#Dxx-#Dyy” on p. 587
“4CSM+#Dxx-#Dyy” on p. 589
“1CSM+#Dxx-E/W” on p. 591
“1CSM+#19xxx-E/W” on p. 593
“2CLSM-#D01-#D64-SFx” on p. 595

Module and System Specification 553


“16CSM-#D01-#D32-SFx” on p. 597
“16CSM-#D33-#D64-SFx” on p. 599
“OSFM+#1490-SFA” on p. 601
“OSFM+#1510-SFB” on p. 603
“2ABSM-#C1470-#C1610” on p. 605
“3BSM-#G1310-#C1610” on p. 607
“4CSM-#Cxxxx-#Cyyyy” on p. 609
“8CSM+#C1470-#C1610” on p. 611
“1CSM+#G1310” on p. 614
“1CSM+#Cxxxx” on p. 616
“5GSM/P-#19590-#19200-DM” on p. 618
“8CSM/P-#C1470-#C1610-DM” on p. 620
“2BSM/P-#C1270-#C1610-DM” on p. 622
“8CSM/P+#C1470-#C1610-DM” on p. 624
“8CSM/P-#19xxx-#19yyy” on p. 626
“8CSM/P-#C1270-#C1450” on p. 629
“1CSM/P+#Cxxxx” on p. 631
“OSFM+#1510” on p. 633

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
“2-OTFM+#1650” on p. 635
“5PSM” on p. 637
“8PSM” on p. 638
“PSM-95/5” on p. 640
“2PSM-95/5” on p. 641
“1PM/SM” on p. 643
“1PM/MM” on p. 644
“2PM/SM” on p. 645
“2PM/MM” on p. 646
“Y-Cable/SM” on p. 647
“Y-Cable/MM” on p. 649
“J/SM/4CS-#C1270-#C1330/LC/0400” on p. 651

554 Module and System Specification


Chapter 9 Optical Filter Modules

ILM50-#DC
The ILM50-#DC is an optical module specifically designed for DWDM in
Dual-Fiber Point-to-Point, linear add/drop, ring and meshed configurations. It
multiplexes and de-multiplexes the “even” and “odd” wavelength channels of the
C band into one fiber pair. "Even" channels refer to the channels with
frequencies of 196.00 THz to 192.00 THz (#D01 to #D32) with a spacing of 100
GHz, while “odd” channels refer to the channels with frequencies of 195.95 THz
to 192.05 THz with a spacing of 100 GHz as well. The total system capacity can
be doubled by upgrading existing 40 channel systems (100 GHz grid) to 80
channels (50 GHz) in the C band.
Table 950 provides general information about the module and its environment.

Table 950: General Information


Equipment type ILM
First release 8.3
Width 4 HP
Height 5 HU
Weight 750 g (1.7 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

office environments only.


MTBF at 25°C ambient temperature 4,802,561 h
Power consumption 1.2 W
Maximum RAM consumption on 19 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical interfaces.

Table 951: Optical Interfaces


Number of client ports (duplex) 2
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

This table provides information about optical characteristics of the interleaver.

Table 952: Optical Characteristics - Interleaver


Insertion loss from Cx-M to N-M max. value < 2 dB
Insertion loss from Cx-M to N-M typ. value < 1.4 dB
Optical return loss > 40 dB
Directivity > 50 dB

Module and System Specification 555


ILM50-#DC

Table 952: Optical Characteristics - Interleaver (Continued)


Uniformity < 1 dB
Passband width N-M 1528 nm - 1562 nm
Passband width C1/C2-M 120 pm (15 GHz)
Max. module delay from C1/C2-M to N-M < 30 ns

This table shows information about the optical characteristics of the


deinterleaver.

Table 953: Optical Characteristics - Deinterleaver


Insertion loss from N-D to Cx-D max. value < 2 dB
Insertion loss from N-D to Cx-D typ. value < 1.65 dB
Optical return loss > 40 dB
Directivity > 50 dB
Uniformity < 1 dB
Isolation > 25 dB
Passband width N-M 1528 nm - 1562 nm
Passband width C1/C2-M 120 pm (15 GHz)
Max. module delay from N-D to C1/C2-D < 30 ns

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

556 Module and System Specification


Chapter 9 Optical Filter Modules

2CLSM-#D01-#D64
The 2CLSM-#D01-#D64 is an optical C-band/L-band splitter that acts as a C/L
band splitter and combiner for DWDM in dual-fiber point-to-point configurations.
The following table contains general information about the 2CLSM.

Table 954: General Information


Equipment type 2CLSM-D
First release 7.0
Width 4 HP
Height 5 HU
Weight 495 g (1.1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 4,761,905 h
Power consumption 1.2 W
Maximum RAM consumption on NCU 22 Kbytes
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

The following table contains information about the optical interfaces.

Table 955: Optical Interfaces


Number of client ports (duplex) 2
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

These tables provide information about the optical characteristics.

Table 956: Optical Characteristics - Multiplexer


Insertion loss max. value 1.5 dB for C band, 1.3 dB for L band
Insertion loss typical value 0.6 dB for C band, 0.4 dB for L band
Optical return loss > 40 dB
Directivity > 50 dB
Latency < 30 ns

Table 957: Optical Characteristics - Demultiplexer


Insertion loss max. value 1.5 dB for C band, 1.5 dB for L band
Insertion loss typical value 0.7 dB for C band, 0.6 dB for L band
Optical return loss > 40 dB
Directivity > 50 dB
Isolation > 30 dB
Latency < 30 ns

Module and System Specification 557


40CSM/2HU-#Dxx-#Dyy

40CSM/2HU-#Dxx-#Dyy
The 40CSM/2HU-#Dxx-#Dyy is a monolithic shelf of 2 HU height without any
kind of modularity supporting the multiplexing and demultiplexing even channels
in dual fiber DWDM point to point configurations.
There are 2 separate shelves, one for the C band and one for the L band:
40CSM/2HU-#D02-#D32 (C band), 40CSM/2HU-#D34-#D64 (L band)
Table 958 provides general information on the module and its environment.

Table 958: General Information


Equipment type 40CSM2HU-D
First release 8.2
Width (dimension without adaptor 445 mm (17.52”)
brackets)
Height 89 mm (3.5”)
Depth (dimension without adaptor 219 mm (8.63”)
brackets)
Weight 4.15 kg (9.2 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2 envi-
IEC 60529 ronment and indoor controlled office

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
environments only.
Power consumption 0.5 W
Maximum RAM consumption on 167 Kbytes
NCU
MTBF at 25°C ambient temperature 1,694,915 h

The following table contains information on the optical interfaces.

Table 959: Optical Interfaces


Number of client ports (duplex) 40
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

This table shows information on the optical characteristics of the multiplexer.

Table 960: Optical Characteristics - Multiplexer


Insertion loss max. value 6 dB
Insertion loss typical value 4.6 dB
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 200 pm (25 GHz)
Latency < 20 ns

558 Module and System Specification


Chapter 9 Optical Filter Modules

The following table provides information on the optical characteristics of the


demultiplexer.
Table 961: Optical Characteristics - Demultiplexer
Insertion loss max. value 6 dB
Insertion loss typical value 4.6 dB
Isolation for adjacent channels > 25 dB
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 200 pm (25 GHz)
Latency < 20 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 559


40CSM/2HU-#19590-#19200

40CSM/2HU-#19590-#19200
The 40CSM/2HU-#19590-#19200 is a monolithic shelf of 2 HU height without
any kind of modularity supporting the multiplexing and demultiplexing of even
channels for fibers to the right in dual fiber DWDM point to point configurations.
Thus it provides 40 client ports and one network port.
Table 962 provides general information on the module and its environment.

Table 962: General Information


Equipment type 40CSM2HU-D
First release 10.3
Width (dimension without adaptor 445 mm (17.52”)
brackets)
Height 89 mm (3.5”)
Depth (dimension without adaptor 219 mm (8.63”)
brackets)
Weight 4.30 kg (9.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2 envi-
IEC 60529 ronment and indoor controlled office
environments only.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Power consumption 0.5 W
Maximum RAM consumption on 167 Kbytes
NCU
MTBF at 25°C ambient temperature 1,694,915 h

The following table contains information on the optical interfaces.

Table 963: Optical Interfaces


Number of client ports (duplex) 40
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

This table shows information on the optical characteristics of the multiplexer.

Table 964: Optical Characteristics - Multiplexer


Insertion loss max. value 6 dB
Insertion loss typical value 4.6 dB
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 200 pm (25 GHz)
Latency < 20 ns

560 Module and System Specification


Chapter 9 Optical Filter Modules

The following table provides information on the optical characteristics of the


demultiplexer.
Table 965: Optical Characteristics - Demultiplexer
Insertion loss max. value 6 dB
Insertion loss typical value 4.6 dB
Isolation for adjacent channels > 25 dB
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 200 pm (25 GHz)
Latency < 20 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 561


40CSM/2HU-#19595-#19205

40CSM/2HU-#19595-#19205
The 40CSM/2HU-#19595-#19205 is a monolithic shelf of 2 HU height without
any kind of modularity supporting the multiplexing and demultiplexing of odd
channels in dual fiber DWDM point to point configurations. Thus it provides 40
client ports and one network port.
Table 966 provides general information on the module and its environment.

Table 966: General Information


Equipment type 40CSM2HU-D
First release 9.1
Width (dimension without adaptor 445 mm (17.52”)
brackets)
Height 89 mm (3.5”)
Depth (dimension without adaptor 219 mm (8.63”)
brackets)
Weight 4.30 kg (9.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2 envi-
IEC 60529 ronment and indoor controlled office
environments only.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Power consumption 0.5 W
Maximum RAM consumption on 167 Kbytes
NCU
MTBF at 25°C ambient temperature 1,694,915 h

The following table contains information on the optical interfaces.

Table 967: Optical Interfaces


Number of client ports (duplex) 40
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

This table shows information on the optical characteristics of the multiplexer.

Table 968: Optical Characteristics - Multiplexer


Insertion loss max. value 6 dB
Insertion loss typical value 4.6 dB
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 200 pm (25 GHz)
Latency < 20 ns

562 Module and System Specification


Chapter 9 Optical Filter Modules

The following table provides information on the optical characteristics of the


demultiplexer.
Table 969: Optical Characteristics - Demultiplexer
Insertion loss max. value 6 dB
Insertion loss typical value 4.6 dB
Isolation for adjacent channels > 25 dB
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 200 pm (25 GHz)
Latency < 20 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 563


40CSM-FL/2HU-#19590-#19200

40CSM-FL/2HU-#19590-#19200
The 40CSM-FL/2HU-#19590-#19200 is a monolithic shelf of 2 HU height
without any kind of modularity supporting the multiplexing and demultiplexing of
even channels for fibers to the left in dual fiber DWDM point to point
configurations. Thus it provides 40 client ports and one network port.
Table 970 provides general information on the module and its environment.

Table 970: General Information


Equipment type 40CSM2HU-D
First release 10.3
Width (dimension without adaptor 445 mm (17.52”)
brackets)
Height 89 mm (3.5”)
Depth (dimension without adaptor 219 mm (8.63”)
brackets)
Weight 4.30 kg (9.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2 envi-
IEC 60529 ronment and indoor controlled office
environments only.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Power consumption 0.5 W
Maximum RAM consumption on 167 Kbytes
NCU
MTBF at 25°C ambient temperature 1,694,915 h

The following table contains information on the optical interfaces.

Table 971: Optical Interfaces


Number of client ports (duplex) 40
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

This table shows information on the optical characteristics of the multiplexer.

Table 972: Optical Characteristics - Multiplexer


Insertion loss max. value 6 dB
Insertion loss typical value 4.6 dB
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 200 pm (25 GHz)
Latency < 20 ns

564 Module and System Specification


Chapter 9 Optical Filter Modules

The following table provides information on the optical characteristics of the


demultiplexer.
Table 973: Optical Characteristics - Demultiplexer
Insertion loss max. value 6 dB
Insertion loss typical value 4.6 dB
Isolation for adjacent channels > 25 dB
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 200 pm (25 GHz)
Latency < 20 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 565


40CSM-C80/2HU-#19xxx-#19yyy

40CSM-C80/2HU-#19xxx-#19yyy
The 40CSM-C80/2HU-#19xxx-#19yyy is a 40-port MUX/DMX channel
splitter/combiner 2HU shelf - C-band channels. It is only be used for dual client
configurations in conjunction with an 8ROADM-C80/0/OPM for an 80-channel
C-band transmission system supporting 50 GHz channel spacing.
There are 2 separate shelves, one for the even C-band channels and one for the
odd C-band channels:
40CSM-C80/2HU-#19590-#19200 (even C-band channels),
40CSM-C80/2HU-#19595-#19205 (odd C-band channels)
Table 974 provides general information on the module and its environment.

Table 974: General Information


Equipment type 40CSM2HU-D
First release 10.2
Width (dimension without adaptor 445 mm (17.52”)
brackets)
Height 89 mm (3.5”)
Depth (dimension without adaptor 219 mm (8.63”)
brackets)
Weight 4.15 kg (9.1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2 envi-
IEC 60529 ronment and indoor controlled office
environments only.
Power consumption 0.5 W
Maximum RAM consumption on 167 Kbytes
NCU
MTBF at 25°C ambient temperature 1,694,915 h

The following table contains information on the optical interfaces.

Table 975: Optical Interfaces


Number of client ports (duplex) 40
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

This table shows information on the optical characteristics of the multiplexer.

Table 976: Optical Characteristics - Multiplexer


Insertion loss max. value 6 dB
Insertion loss typical value 5.1 dB
Directivity > 45 dB
Optical return loss > 40 dB

566 Module and System Specification


Chapter 9 Optical Filter Modules

Table 976: Optical Characteristics - Multiplexer (Continued)


Passband width 200 pm (25 GHz)
Latency < 25 ns

The following table provides information on the optical characteristics of the


demultiplexer.
Table 977: Optical Characteristics - Demultiplexer
Insertion loss max. value 6 dB
Insertion loss typical value 4.9 dB
Isolation in stopband for 50 GHz > 18 dB
adjacent channels
Isolation in stopband for 100 GHz > 25 dB
adjacent channels
Directivity > 45 dB
Optical return loss > 40 dB
Passband width 120 pm (15 GHz)
Latency < 25 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 567


40CSM/P-2HU#19590-#19200-DM

40CSM/P-2HU#19590-#19200-DM
The 40CSM/P-2HU#19590-#19200-DM is a passive 40-port MUX/DMX channel
splitter and combiner 2HU shelf with monitoring port for dual power level
monitoring. It is a monolithic shelf of 2 HU height including channel MUX and
DEMUX filters and monitor taps.

This device is passive and not detected or visible through system


PS

inventory. The shelf is not visible by inventory management, Control


Plane, or the Network Manager system.
Note

Table 978 provides general information on the module and its environment.

Table 978: General Information


Equipment type -
First release 10.2
Width (dimension without adaptor 445 mm (17.52”)
brackets)
Height 89 mm (3.5”)
Depth (dimension without adaptor 219 mm (8.63”)
brackets)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Weight 4.2 kg (9.3 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1,
extended temperature range -25°C to
+70°C with insertion loss penalty
Degree of protection according to IP20. Use in a pollution degree 2 envi-
IEC 60529 ronment and indoor controlled office
environments only.
Power consumption -
MTBF at 25°C ambient temperature 1,639,344 h

The following table contains information on the optical interfaces.

Table 979: Optical Interfaces


Number of client ports (duplex) 40
Number of monitoring ports 1 (for ingress and egress at the
(duplex) network port)
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

568 Module and System Specification


Chapter 9 Optical Filter Modules

This table shows information on the optical characteristics of the multiplexer.

Table 980: Optical Characteristics - Multiplexer


Insertion loss max. value 6.5 dB
Insertion loss typical value 4.8 dB
Insertion loss client ports to < 22 dB
monitoring port max. value
Insertion loss penalty at all 0.5 dB
interfaces for temperature range
-25°C to +70°C
Directivity > 50 dB
Optical return loss > 40 dB
Passband width client interface 200 pm (25 GHz)
Latency < 20 ns

The following table provides information on the optical characteristics of the


demultiplexer.
Table 981: Optical Characteristics - Demultiplexer
Insertion loss max. value 6.5 dB
Insertion loss typical value 4.8 dB
Insertion loss network port to < 16.5 dB
monitoring port max. value
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Insertion loss penalty at all 0.5 dB


interfaces for temperature range
-25°C to +70°C
Isolation for adjacent channels > 25 dB
Accumulative crosstalk of all neigh- < -22 dB
boring channels client interface Tx
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 200 pm (25 GHz)
Latency < 20 ns

Module and System Specification 569


96CSM/4HU-#19600-#19125

96CSM/4HU-#19600-#19125
The 96CSM/4HU-#19600-#19125 is a monolithic shelf of 4 HU height without
any kind of modularity supporting the multiplexing and demultiplexing of 96
C-band channels. Thus it provides 96 client ports and one network port. In
addition, the shelf has one fiber detection client port and one fiber detection
network port for monitoring the availability of the attached fibers.
In addition the 96CSM/4HU-#19600-#19125 can be used in 80 channel systems
as replacement of 2x40CSM plus ILM.
Table 982 provides general information about the module and its environment.

Table 982: General Information


Equipment type 96CSM-4HU-D
First release 11.2
Width (dimension without adaptor 445 mm (17.52”)
brackets)
Height 177.8 mm (7.0”)
Depth (dimension without adaptor 219 mm (8.63”)
brackets)
Weight 6.5 kg (14.33 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS)
ETSI EN 300-019-1-2 class 1.2 and

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
2.3
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2 envi-
IEC 60529 ronment and indoor controlled office
environments only.
Power consumption 0.5 W
Maximum RAM consumption on 393 Kbytes
NCU
MTBF at 25°C ambient temperature 337,268 h

Table 983 provides information about the optical interfaces.

Table 983: Optical Interfaces


Number of client ports (duplex) 96
Number of fiber detection client port 1 (for ingress and egress at the client
(duplex) port)
Number of network ports (duplex) 1
Number of fiber detection network 1 (for ingress and egress at the net-
port (duplex) work port)
Optical connector type LC
Fiber type SM G.652

570 Module and System Specification


Chapter 9 Optical Filter Modules

Table 984 provides information about the optical characteristics of the


multiplexer.

Table 984: Optical Characteristics - Multiplexer


Insertion loss max. value < 8.0 dB
Directivity > 45 dB
Passband width 120 pm (15 GHz)
Latency < 35 ns
Insertion loss network port Rx to network < 1.3 dB
fiber detection port Tx
Insertion loss client port Rx to client fiber < 22 dB
detection port Tx
Directivity network fiber detection port Rx to > 50 dB
network fiber detection port Tx
Return loss network fiber detection port Rx > 40 dB
Passband network fiber detection port Rx 1290 nm - 1330 nm

Table 985 provides information about the optical characteristics of the


demultiplexer.
Table 985: Optical Characteristics - Demultiplexer
Insertion loss max. value < 8.0 dB
Isolation for adjacent channels > 22 dB
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Directivity > 45 dB
Passband width 120 pm (15 GHz)
Latency < 35 ns
Insertion loss client fiber detection port Rx to < 22 dB
client port Tx
Insertion loss network port Rx to network < 1.3 dB
fiber detection port Tx
Directivity client fiber detection port Rx to cli- > 45 dB
ent fiber detection port Tx
Isolation network fiber detection port Tx > 25 dB
Passband network fiber detection port Tx 1290 nm - 1330 nm

Module and System Specification 571


2BSM-#D01-#D32

2BSM-#D01-#D32
The 2BSM-#D01-#D32 is an optical module that acts as a red/blue subband
splitter and combiner for DWDM in linear add/drop and ring configurations.
The 2BSM-#D01-#D32 contains a combination of specific subband MUX and
DEMUX filters that combine/split the red and blue subband channel signals of
the C band into/from the full duplex signal carried by the network fiber pair. The
blue subbands comprise the shorter wavelengths, channels #D01-#D16. The
red subbands include the longer wavelengths, channels #D17-#D32.
Table 986 provides general information about the module and its environment.

Table 986: General Information


Equipment type 2BSM-D
First release 7.0
Width 4 HP
Height 5 HU
Weight 560 g (1.2 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 10,000,000 h
Power consumption 1.2 W
Maximum RAM consumption on 26 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical interfaces.

Table 987: Optical Interfaces


Number of client ports (duplex) 2
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

This table shows information about the optical characteristics of the multiplexer.

Table 988: Optical Characteristics - Multiplexer


Insertion loss max. value 1.5 dB (all ports)
Insertion loss typical value 0.8 dB (all ports)
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 30 ns

572 Module and System Specification


Chapter 9 Optical Filter Modules

The following table provides information about the optical characteristics of the
demultiplexer.

Table 989: Optical Characteristics - Demultiplexer


Insertion loss max. value 1.5 dB (all ports)
Insertion loss typical value 0.7 dB (all ports)
Directivity > 50 dB
Optical return loss > 40 dB
Isolation > 32 dB
Latency < 30 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 573


4GSM-#Dxx-#Dyy

4GSM-#Dxx-#Dyy
The 4GSM-#Dxx-#Dyy is an optical channel group splitter and combiner
module. The module is available in two variants (4GSM-#D01-#D16 and
(4GSM-#D17-#D32) for supporting the C-band channels.
Table 990 provides general information about the module and its environment.

Table 990: General Information


Equipment type 4GSM-D
First release 7.0
Width 4 HP
Height 5 HU
Weight 600 g (1.3 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 18,518,519 h
Power consumption 1.2 W
Maximum RAM consumption on 22 Kbytes
NCU

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical interfaces.

Table 991: Optical Interfaces


Number of client ports (duplex) 4
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

This table shows information about the optical characteristics of the multiplexer.

Table 992: Optical Characteristics - Multiplexer


Insertion loss max. value
#D01-#D04, #D17-#D20 2.6 dB (port C1)
#D05-#D08, #D21-#D24 2.2 dB (port C2)
#D09-#D12, #D25-#D28 1.8 dB (port C3)
#D13-#D16, #D29-#D32 1.4 dB (port C4)
Insertion loss typical value
#D01-#D04, #D17-#D20 1.4 dB (port C1)
#D05-#D08, #D21-#D24 1.1 dB (port C2)
#D09-#D12, #D25-#D28 0.9 dB (port C3)
#D13-#D16, #D29-#D32 0.6 dB (port C4)

574 Module and System Specification


Chapter 9 Optical Filter Modules

Table 992: Optical Characteristics - Multiplexer (Continued)


Directivity > 50 dB
Optical return loss > 40 dB
Latency < 75 ns

This table shows information about the optical characteristics of the


demultiplexer.

Table 993: Optical Characteristics - Demultiplexer


Insertion loss max. value
#D01-#D04, #D17-#D20 1.4 dB (port C1)
#D05-#D08, #D21-#D24 1.8 dB (port C2)
#D09-#D12, #D25-#D28 2.2 dB (port C3)
#D13-#D16, #D29-#D32 2.6 dB (port C4)
Insertion loss typical value
#D01-#D04, #D17-#D20 0.6 dB (port C1)
#D05-#D08, #D21-#D24 0.8 dB (port C2)
#D09-#D12, #D25-#D28 1.1 dB (port C3)
#D13-#D16, #D29-#D32 1.3 dB (port C4)
Directivity > 50 dB
Optical return loss > 40 dB
Isolation adjacent groups > 32 dB
Isolation non-adjacent groups > 40 dB
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Latency < 75 ns

Module and System Specification 575


8GSM-#D01-#D32

8GSM-#D01-#D32
The 8GSM-#D01-#D32 is an optical channel group splitter and combiner
module. The module supports the channels #D01 through #D32 of the C band.
Table 994 provides general information about the module and its environment.

Table 994: General Information


Equipment type 8GSM-D
First release 7.0
Width 8 HP
Height 5 HU
Weight 790 g (1.7 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 3,597,122 h
Power consumption 1.2 W
Maximum RAM consumption on NCU 39 Kbytes
Slot positions SH9HU: 3...17

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SH7HU, SH7HU-R: 3...17
SH1HU: 1

The following table contains information about the optical interfaces.

Table 995: Optical Interfaces


Number of client ports (duplex) 8
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

576 Module and System Specification


Chapter 9 Optical Filter Modules

This table shows information about the optical characteristics of the multiplexer.
Table 996: Optical Characteristics - Multiplexer
Insertion loss max. value
#D01-#D04 3.8 dB (port C1)
#D05-#D08 3.3 dB (port C2)
#D09-#D12 2.8 dB (port C3)
#D13-#D16 2.3 dB (port C4)
#D17-#D20 3.5 dB (port C5)
#D21-#D24 3 dB (port C6)
#D25-#D28 2.5 dB (port C7)
#D29-#D32 2 dB (port C8)
Insertion loss typical value
#D01-#D04 1.8 dB (port C1)
#D05-#D08 1.5 dB (port C2)
#D09-#D12 1.2 dB (port C3)
#D13-#D16 1 dB (port C4)
#D17-#D20 1.6 dB (port C5)
#D21-#D24 1.3 dB (port C6)
#D25-#D28 1.1 dB (port C7)
#D29-#D32 0.8 dB (port C8)
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 105 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

This table shows information about optical characteristics of the demultiplexer.

Table 997: Optical Characteristics - Demultiplexer


Insertion loss max. value
#D01-#D04 2 dB (port C1)
#D05-#D08 2.5 dB (port C2)
#D09-#D12 3 dB (port C3)
#D13-#D16 3.5 dB (port C4)
#D17-#D20 2.3 dB (port C5)
#D21-#D24 2.8 dB (port C6)
#D25-#D28 3.3 dB (port C7)
#D29-#D32 3.8 dB (port C8)
Insertion loss typical value
#D01-#D04 0.9 dB (port C1)
#D05-#D08 1.1 dB (port C2)
#D09-#D12 1.3 dB (port C3)
#D13-#D16 1.5 dB (port C4)
#D17-#D20 1 dB (port C5)
#D21-#D24 1.2 dB (port C6)
#D25-#D28 1.4 dB (port C7)
#D29-#D32 1.7 dB (port C8)
Directivity > 50 dB
Optical return loss > 40 dB
Isolation adjacent groups > 32 dB
Isolation non-adjacent groups > 40 dB
Latency < 105 ns

Module and System Specification 577


1GSM+#Dxx-#Dyy

1GSM+#Dxx-#Dyy
The 1GSM+#Dxx-#Dyy is an optical channel group splitter and combiner
module.
There are 8 separate modules for all C-band groups:
1GSM+#D01-#D04, 1GSM+#D05-#D08, 1GSM+#D09-#D12, 
1GSM+#D13-#D16, 1GSM+#D17-#D20, 1GSM+#D21-#D24, 
1GSM+#D25-#D28, 1GSM+#D29-#D32
Table 998 provides general information about the module and its environment.

Table 998: General Information


Equipment type 1GSMU-D
First release 7.0
Width 4 HP
Height 5 HU
Weight 490 g (1.08 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption 1.2 W

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Maximum RAM consumption on 24 Kbytes
NCU
MTBF at 25°C ambient temperature 26,315,790 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical interfaces.

Table 999: Optical Interfaces


Number of client ports (duplex) 1
Number of upgrade ports (duplex) 1
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

This table shows information about the optical characteristics of the multiplexer.

Table 1000: Optical Characteristics - Multiplexer


Insertion loss max. value 1.5 dB for add port, 1.3 dB for upgrade port
Insertion loss typical value 0.6 dB for add port, 0.6 dB for upgrade port
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 30 ns

578 Module and System Specification


Chapter 9 Optical Filter Modules

This table shows information about the optical characteristics of the multiplexer.

Table 1001: Optical Characteristics - Demultiplexer


Insertion loss max. value 1.5 dB for drop port, 1.5 dB for upgrade port
Insertion loss typical value 0.6 dB for drop port, 0.6 dB for upgrade port
Directivity > 50 dB
Optical return loss > 40 dB
Isolation > 30 dB for drop port
> 12 dB for upgrade port
Latency < 30 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 579


5GSM-#19590-#19200

5GSM-#19590-#19200
The 5GSM-#19590-#19200 is a 5-port optical channel group splitter and
combiner module. The module contains optical filters, that combine/split five
separate channel group signals. It performs multiplex and de-multiplex
operation on a full duplex network fiber pair.
Table 1002 provides general information about the module and its environment.

Table 1002: General Information


Equipment type 5GSM-D
First release 9.3
Width 4 HP
Height 5 HU
Weight 650 g (1.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 7,142,857 h
Power consumption 1.2 W
Maximum RAM consumption on NCU 31 Kbytes
Slot positions SH9HU: 3...18

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical interfaces.

Table 1003: Optical Interfaces


Number of client ports (duplex) 5
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

This table shows information about the optical characteristics of the multiplexer.

Table 1004: Optical Characteristics - Multiplexer


Insertion loss max. value
#19590 - #19520 3.5 dB (port C1)
#19510 - #19440 3 dB (port C2)
#19430 - #19360 2.5 dB (port C3)
#19350 - #19280 2 dB (port C4)
#19270 - #19200 1.5 dB (port C5)
Insertion loss typical value
#19590 - #19520 2 dB (port C1)
#19510 - #19440 2 dB (port C2)
#19430 - #19360 1.9 dB (port C3)
#19350 - #19280 1.5 dB (port C4)
#19270 - #19200 1.1 dB (port C5)

580 Module and System Specification


Chapter 9 Optical Filter Modules

Table 1004: Optical Characteristics - Multiplexer (Continued)


Directivity > 50 dB
Optical return loss > 40 dB
Latency < 40 ns

This table shows information about the optical characteristics of the


demultiplexer.

Table 1005: Optical Characteristics - Demultiplexer


Insertion loss max. value
#19590 - #19520 1.5 dB (port C1)
#19510 - #19440 2 dB (port C2)
#19430 - #19360 2.5 dB (port C3)
#19350 - #19280 3 dB (port C4)
#19270 - #19200 3.5 dB (port C5)
Insertion loss typical value
#19590 - #19520 1.1 dB (port C1)
#19510 - #19440 1.5 dB (port C2)
#19430 - #19360 1.9 dB (port C3)
#19350 - #19280 2 dB (port C4)
#19270 - #19200 2 dB (port C5)
Directivity > 50 dB
Optical return loss > 40 dB
Isolation adjacent groups > 15 dB
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Isolation non-adjacent groups > 30 dB


Latency < 40 ns

Module and System Specification 581


8CSM-#19xxx-#19yyy

8CSM-#19xxx-#19yyy
The 8CSM-#19xxx-#19yyy is an optical 8-port DWDM channel splitter and
combiner module for the C band.
There are five module variants covering the C band:
8CSM-#19590-#19520, 8CSM-#19510-#19440, 8CSM-#19430-#19360,
8CSM-#19350-#19280, 8CSM-#19270-#19200
Table 1006 provides general information about the module and its environment.

Table 1006: General Information


Equipment type 8CSM-D
First release 9.3
Width 8 HP
Height 5 HU
Weight 800 g (1.7 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption 1.2 W

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Maximum RAM consumption on NCU 35 Kbytes
MTBF at 25°C ambient temperature 3,649,635 h
Slot positions SH9HU: 3...17
SH7HU, SH7HU-R: 3...17
SH1HU: 1

The following table contains information about the optical interfaces.

Table 1007: Optical Interfaces


Number of client ports (duplex) 8
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

582 Module and System Specification


Chapter 9 Optical Filter Modules

This table shows information about the optical characteristics of the multiplexer.

Table 1008: Optical Characteristics - Multiplexer


Insertion loss max. value (port dependent)
port C1 3.7 dB
port C2 3.5 dB
port C3 3.3 dB
port C4 3 dB
port C5 2.7 dB
port C6 2.4 dB
port C7 2.1 dB
port C8 1.8 dB
Insertion loss typ. value (port dependent)
port C1 1.90 dB
port C2 1.80 dB
port C3 1.50 dB
port C4 1.40 dB
port C5 1.20 dB
port C6 0.95 dB
port C7 0.85 dB
port C8 0.70 dB
Directivity > 50 dB
Optical return loss > 40 dB
Passband width at 3 dB 250 pm (31.25 GHz)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Latency < 135 ns

The following table provides information about the optical characteristics of the
demultiplexer.

Table 1009: Optical Characteristics - Demultiplexer


Insertion loss max. value (port dependent)
port C1 1.8 dB
port C2 2.1 dB
port C3 2.4 dB
port C4 2.7 dB
port C5 3 dB
port C6 3.3 dB
port C7 3.5 dB
port C8 3.7 dB
Insertion loss typ. value (port dependent)
port C1 0.60 dB
port C2 0.80 dB
port C3 0.95 dB
port C4 1.10 dB
port C5 1.25 dB
port C6 1.45 dB
port C7 1.70 dB
port C8 1.80 dB
Directivity > 50 dB

Module and System Specification 583


8CSM-#19xxx-#19yyy

Table 1009: Optical Characteristics - Demultiplexer


Isolation for adjacent channels > 32 dB
Isolation non-adjacent groups > 40 dB
Optical return loss > 40 dB
Passband width at 3 dB 250 pm (31.25 GHz)
Latency < 135 ns

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

584 Module and System Specification


Chapter 9 Optical Filter Modules

4CSM+#19xxx-#19yyy
The 4CSM+#19xxx-#19yyy is a 4- port optical channel splitter and combiner
module.
The module contains a combination of specific MUX/DEMUX filters which
allows access to specific channels of the C band from a network fiber while
passing through the remaining channel spectrum.
There are 10 separate modules covering C-band channels:
4CSM+#19590-#19560, 4CSM+#19550-#19520, 4CSM+#19510-#19480,
4CSM+#19470-#19440, 4CSM+#19430-#19400, 4CSM+#19390-#19360,
4CSM+#19350-#19320, 4CSM+#19310-#19280, 4CSM+#19270-#19240,
4CSM+#19230-#19200
Table 1010 provides general information about the module and its environment.

Table 1010: General Information


Equipment type 4CSMU-D
First release 9.1
Width 4 HP
Height 5 HU
Weight 650 g (1.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Degree of protection according to IP20. Use in a pollution degree 2


IEC 60529 environment and indoor controlled
office environments only.
Power consumption 1.2 W
Maximum RAM consumption on 42 Kbytes
NCU
MTBF at 25°C ambient temperature 14,705,883 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical interfaces.

Table 1011: Optical Interfaces


Number of client ports (duplex) 4
Number of upgrade ports (duplex) 1
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

Module and System Specification 585


4CSM+#19xxx-#19yyy

This table shows information about the optical characteristics of the multiplexer.

Table 1012: Optical Characteristics - Multiplexer


Insertion loss max. value (port dependent)
port C1 3.2 dB
port C2 2.8 dB
port C3 2.4 dB
port C4 2 dB
for upgrade port 1.6 dB
Insertion loss typical value (port dependent)
port C1 1.9 dB
port C2 1.6 dB
port C3 1.4 dB
port C4 1.2 dB
for upgrade port 0.6 dB
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 250 pm (31.25 GHz)
Latency < 90 ns

The following table provides information about the optical characteristics of the
demultiplexer.

Table 1013: Optical Characteristics - Demultiplexer

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Insertion loss max. value (port dependent)
port C1 2 dB
port C2 2.4 dB
port C3 2.8 dB
port C4 3.2 dB
for upgrade port 1.6 dB
Insertion loss typical value (port dependent)
port C1 1.2 dB
port C2 1.4 dB
port C3 1.6 dB (port C3)
port C4 1.8 dB (port C4)
for upgrade port 0.6 dB
Directivity > 50 dB
Isolation for adjacent channels > 30 dB
Optical return loss > 40 dB
Passband width 250 pm (31.25 GHz)
Latency < 90 ns

586 Module and System Specification


Chapter 9 Optical Filter Modules

4CSM-#Dxx-#Dyy
The 4CSM-#Dxx-#Dyy is an optical channel splitter and combiner module. It
contains a combination of MUX and DEMUX channel filters for the C band.
There are 8 separate modules for all C-band groups:
4CSM-#D01-#D04, 4CSM-#D05-#D08, 4CSM-#D09-#D12, 4CSM-#D13-#D16, 
4CSM-#D17-#D20, 4CSM-#D21-#D24, 4CSM-#D25-#D28, 4CSM-#D29-#D32
Table 1014 provides general information about the module and its environment.

Table 1014: General Information


Equipment type 4CSM-D
First release 7.0
Width 4 HP
Height 5 HU
Weight 600 g (1.3 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption 1.2 W
Maximum RAM consumption on 41 Kbytes
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

NCU
MTBF at 25°C ambient temperature 17,241,380 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical interfaces.

Table 1015: Optical Interfaces


Number of client ports (duplex) 4
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

Module and System Specification 587


4CSM-#Dxx-#Dyy

This table shows information about the optical characteristics of the multiplexer.

Table 1016: Optical Characteristics - Multiplexer


Insertion loss max. value (port dependent)
#D01, #D05, #D09... 2.6 dB (port C1)
#D02, #D06, #D10... 2.2 dB (port C2)
#D03, #D07, #D11... 1.8 dB (port C3)
#D04, #D08, #D12... 1.4 dB (port C4)
Insertion loss typical value (port dependent)
#D01, #D05, #D09... 1.5 dB (port C1)
#D02, #D06, #D10... 1.2 dB (port C2)
#D03, #D07, #D11... 1 dB (port C3)
#D04, #D08, #D12... 0.7 dB (port C4)
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 250 pm (31.25 GHz)
Latency < 75 ns

The following table provides information about the optical characteristics of the
demultiplexer.

Table 1017: Optical Characteristics - Demultiplexer


Insertion loss max. value (port dependent)
#D01, #D05, #D09... 1.4 dB (port C1)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
#D02, #D06, #D10... 1.8 dB (port C2)
#D03, #D07, #D11... 2.2 dB (port C3)
#D04, #D08, #D12... 2.6 dB (port C4)
Insertion loss typical value
#D01, #D05, #D09... 0.7 dB (port C1)
#D02, #D06, #D10... 1 dB (port C2)
#D03, #D07, #D11... 1.2 dB (port C3)
#D04, #D08, #D12... 1.4 dB (port C4)
Isolation for adjacent channels > 30 dB
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 250 pm (31.25 GHz)
Latency < 75 ns

588 Module and System Specification


Chapter 9 Optical Filter Modules

4CSM+#Dxx-#Dyy
The 4CSM+#Dxx-#Dyy is an optical channel splitter and combiner module.
The module contains a combination of specific add/drop optical filters and
MUX/DEMUX filters which allows access to four specific channels of the C band
from a network fiber while passing through the remaining channel spectrum.
There are 8 separate modules for all C-band groups:
4CSM+#D01-#D04, 4CSM+#D05-#D08, 4CSM+#D09-#D12, 
4CSM+#D13-#D16, 4CSM+#D17-#D20, 4CSM+#D21-#D24, 
4CSM+#D25-#D28, 4CSM+#D29-#D32
Table 1018 provides general information about the module and its environment.

Table 1018: General Information


Equipment type 4CSMU-D
First release 7.0
Width 4 HP
Height 5 HU
Weight 650 g (1.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

IEC 60529 environment and indoor controlled


office environments only.
Power consumption 1.2 W
Maximum RAM consumption on 42 Kbytes
NCU
MTBF at 25°C ambient temperature 12,500,000 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical interfaces.

Table 1019: Optical Interfaces


Number of client ports (duplex) 4
Number of upgrade ports (duplex) 1
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

Module and System Specification 589


4CSM+#Dxx-#Dyy

This table shows information about the optical characteristics of the multiplexer.

Table 1020: Optical Characteristics - Multiplexer


Insertion loss max. value (port dependent)
#D01, #D05, #D09... 3.2 dB (port C1)
#D02, #D06, #D10... 2.8 dB (port C2)
#D03, #D07, #D11... 2.4 dB (port C3)
#D04, #D08, #D12... 2 dB (port C4)
for upgrade port 1.4 dB
Insertion loss typical value (port dependent)
#D01, #D05, #D09... 1.9 dB (port C1)
#D02, #D06, #D10... 1.6 dB (port C2)
#D03, #D07, #D11... 1.4 dB (port C3)
#D04, #D08, #D12... 1.2 dB (port C4)
for upgrade port 0.6 dB
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 250 pm (31.25 GHz)
Latency < 90 ns

The following table provides information about the optical characteristics of the
demultiplexer.

Table 1021: Optical Characteristics - Demultiplexer

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Insertion loss max. value (port dependent)
#D01, #D05, #D09... 2 dB (port C1)
#D02, #D06, #D10... 2.4 dB (port C2)
#D03, #D07, #D11... 2.8 dB (port C3)
#D04, #D08, #D12... 3.2 dB (port C4)
for upgrade port 1.4 dB
Insertion loss typical value (port dependent)
#D01, #D05, #D09... 1.2 dB (port C1)
#D02, #D06, #D10... 1.4 dB (port C2)
#D03, #D07, #D11... 1.6 dB (port C3)
#D04, #D08, #D12... 1.8 dB (port C4)
for upgrade port 0.6 dB
Directivity > 50 dB
Isolation for adjacent channels > 30 dB
Optical return loss > 40 dB
Passband width 250 pm (31.25 GHz)
Latency < 90 ns

590 Module and System Specification


Chapter 9 Optical Filter Modules

1CSM+#Dxx-E/W
The 1CSM+#Dxx-E/W is an optical east/west single channel DWDM splitter and
combiner module. On a per-wavelength basis it allows access to a specific
channel from an east-side and west-side network fiber pair while passing the
remaining channel spectrum.
There are 32 separate modules:
1CSM+#D01-E/W, 1CSM+#D02-E/W, 1CSM+#D03-E/W, 1CSM+#D04-E/W,
1CSM+#D05-E/W, 1CSM+#D06-E/W, 1CSM+#D07-E/W, 1CSM+#D08-E/W,
1CSM+#D09-E/W, 1CSM+#D10-E/W, 1CSM+#D11-E/W, 1CSM+#D12-E/W,
1CSM+#D13-E/W, 1CSM+#D14-E/W, 1CSM+#D15-E/W, 1CSM+#D16-E/W,
1CSM+#D17-E/W, 1CSM+#D18-E/W, 1CSM+#D19-E/W, 1CSM+#D20-E/W,
1CSM+#D21-E/W, 1CSM+#D22-E/W, 1CSM+#D23-E/W, 1CSM+#D24-E/W,
1CSM+#D25-E/W, 1CSM+#D26-E/W, 1CSM+#D27-E/W, 1CSM+#D28-E/W,
1CSM+#D29-E/W, 1CSM+#D30-E/W, 1CSM+#D31-E/W, 1CSM+#D32-E/W
Table 1022 provides general information on the module and its environment.

Table 1022: General Information


Equipment type 1CSMU-EW-D
First release 7.0
Width 4 HP
Height 5 HU
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Weight 590 g (1.3 lbs)


Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2 envi-
IEC 60529 ronment and indoor controlled office
environments only.
Power consumption <2W
Maximum RAM consumption on 39 Kbytes
NCU
MTBF at 25°C ambient temperature 10,000,001 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information on the optical interfaces.

Table 1023: Optical Interfaces


Number of client ports (duplex) 2
Number of upgrade ports (duplex) 2
Number of network ports (duplex) 2
Optical connector type LC
Fiber type SM G.652

Module and System Specification 591


1CSM+#Dxx-E/W

This table shows information on the optical characteristics of the multiplexer.

Table 1024: Optical Characteristics - Multiplexer


Number of optical systems 2
Insertion loss max. value 1.5 dB for add port, 1.5 dB for upgrade
port
Insertion loss typical value 0.7 dB for add port, 0.7 dB for upgrade
port
Passband width 250 pm (31.25 GHz)
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 30 ns

The following table provides information on the optical characteristics of the


demultiplexer.

Table 1025: Optical Characteristics - Demultiplexer


Number of optical systems 1
Insertion loss max. value 1.5 dB for drop port, 1.5 dB for
upgrade port
Insertion loss typical value 1.2 dB for drop port, 0.7 dB for
upgrade port
Passband width 250 pm (31.25 GHz)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Isolation > 55 dB for drop port
> 26 dB for upgrade port
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 30 ns

592 Module and System Specification


Chapter 9 Optical Filter Modules

1CSM+#19xxx-E/W
The 1CSM+#19xxx-E/W is an optical east/west single channel DWDM splitter
and combiner module. On a per-wavelength basis it allows access to a specific
C band channel from an east-side and west-side network fiber pair while
passing the remaining channel spectrum.
There are 9 separate modules for specific channels in the C band:
1CSM+#19560-E/W, 1CSM+#19510-E/W, 1CSM+#19460-E/W,
1CSM+#19410-E/W, 1CSM+#19400-E/W, 1CSM+#19390-E/W,
1CSM+#19340-E/W, 1CSM+#19290-E/W, 1CSM+#19240-E/W
Table 1026 provides general information on the module and its environment.

Table 1026: General Information


Equipment type 1CSMU-EW-D
First release 9.1
Width 4 HP
Height 5 HU
Weight 590 g (1.3 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

office environments only.


Power consumption 1.2 W
Maximum RAM consumption on NCU 39 Kbytes
MTBF at 25°C ambient temperature 10,000,001 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information on the optical interfaces.

Table 1027: Optical Interfaces


Number of client ports (duplex) 2
Number of upgrade ports (duplex) 2
Number of network ports (duplex) 2
Optical connector type LC
Fiber type SM G.652

Module and System Specification 593


1CSM+#19xxx-E/W

This table shows information on the optical characteristics of the multiplexer.

Table 1028: Optical Characteristics - Multiplexer


Number of optical systems 2
Insertion loss max. value 1.5 dB for add port, 1.5 dB for upgrade port
Insertion loss typical value 0.7 dB for add port, 0.7 dB for upgrade port
Passband width 250 pm (31.25 GHz)
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 30 ns

The following table provides information on the optical characteristics of the


demultiplexer.

Table 1029: Optical Characteristics - Demultiplexer


Number of optical systems 1
Insertion loss max. value 1.5 dB for drop port, 1.5 dB for
upgrade port
Insertion loss typical value 1.2 dB for drop port, 0.7 dB for
upgrade port
Passband width 250 pm (31.25 GHz)
Isolation > 55 dB for drop port
> 26 dB for upgrade port

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 30 ns

594 Module and System Specification


Chapter 9 Optical Filter Modules

2CLSM-#D01-#D64-SFx
The 2CLSM-#D01-#D64-SFx is an optical module that acts as C/L band splitter
and combiner for DWDM in single-fiber working point-to-point configurations.
The “x” at the end of the module name stands for the location A or B.
The 2CLSM-#D01-#D64-SFA multiplexes the channels #D01-#D16 and
#D33-#D48, and demultiplexes the channels #D17-#D32 and #D49-#D64, while
the 2CLSM-#D01-#D64-SFB demultiplexes the channels #D01-#D16 and
#D33-#D48 and multiplexes the channels #D17-#D32 and #D49-#D64.
Table 1030 provides general information about the module and its environment.

Table 1030: General Information


Equipment type 2CLSM-SF-D
First release 8.1
Width 4 HP
Height 5 HU
Weight 470 g (1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

MTBF at 25°C ambient temperature 8,333,333 h


Power consumption 1.2 W
Maximum RAM consumption on 26 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical interfaces.

Table 1031: Optical Interfaces


Number of client ports (duplex) 2
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

This table provides information about the optical characteristics of the


multiplexer.

Table 1032: Optical Characteristics - Multiplexer


Insertion loss max. value 1.5 dB for C band, 1.3 dB for L band
Insertion loss typical value 0.6 dB for C band, 0.4 dB for L band
Optical return loss > 40 dB
Directivity > 50 dB
Latency < 30 ns

Module and System Specification 595


2CLSM-#D01-#D64-SFx

This table shows information about the optical characteristics of the


demultiplexer.

Table 1033: Optical Characteristics - Demultiplexer


Insertion loss max. value 1.5 dB for C band, 1.5 dB for L band
Insertion loss typical value 0.7 dB for C band, 0.6 dB for L band
Optical return loss > 40 dB
Directivity > 50 dB
Isolation > 30 dB
Latency < 30 ns

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

596 Module and System Specification


Chapter 9 Optical Filter Modules

16CSM-#D01-#D32-SFx
The 16CSM-#D01-#D32-SFx is a bi-directional channel splitter and combiner
for DWDM in single-fiber point-to-point configurations. It includes a combination
of specific channel and channel group MUX/DEMUX filters that handle the
combining/splitting individual channels within the C band (#D01 to #D32)
into/from the full duplex network signal.
Table 1034 provides general information about the module and its environment.

Table 1034: General Information


Equipment type 16CSM-SF-D
First release 8.1
Width 16 HP
Height 5 HU
Weight 1.66 kg (3.7 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption 1.2 W
Maximum RAM consumption on 53 Kbytes
NCU
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

MTBF at 25°C ambient temperature 3,607,113 h


Slot positions SH9HU: 3...15
SH7HU, SH7HU-R: 3...15

The following table contains information about the optical interfaces.

Table 1035: Optical Interfaces


Number of client ports 16
Number of network ports 1
Number of other ports 2
Optical connector type LC
Fiber type SM G.652

This table shows information about the optical characteristics of the multiplexer.
Table 1036: Optical Characteristics - Multiplexer
Insertion loss Cx-M to Booster-T (port dependent)
C1, C2, C3, C4, 6.7 dB, 6.3 dB, 5.9 dB, 5.5 dB
C5, C6, C7, C8, 6.3 dB, 5.9 dB, 5.5 dB, 5.1 dB
C9, C10, C11, C12 5.9 dB, 5.5 dB, 5.1 dB, 4.7 dB
C13, C14, C15, C16 5.5 dB, 5.1 dB, 4.7 dB, 4.3 dB
Insertion loss typical value (port dependent)
C1, C2, C3, C4 2.9 dB, 2.7 dB, 2.4 dB, 2.3 dB
C5, C6, C7, C8 2.6 dB, 2.4 dB, 2.3 dB, 2.1 dB
C9, C10, C11, C12 2.4 dB, 2.2 dB, 2 dB, 1.7 dB
C13, C14, C15, C16 2.4 dB, 2.1 dB, 1.8 dB, 1.7 dB

Module and System Specification 597


16CSM-#D01-#D32-SFx

Table 1036: Optical Characteristics - Multiplexer (Continued)


Directivity > 50 dB
Insertion loss Booster-R to network port < 1.5 dB
Return loss Cx-M ports > 40 dB
Return loss Booster-T > 40 dB
Passband width 250 pm (31.25 GHz)
Latency Cx-M to Booster-R < 150 ns
Latency Booster-T to network port < 30 ns

This table shows information about the optical characteristics of the


demultiplexer.

Table 1037: Optical Characteristics - Demultiplexer


Insertion loss Preamp-R to Cx-D (port dependent)
C1, C2, C3, C4 4.3 dB, 4.7 dB, 5.1 dB, 5.5 dB
C5, C6, C7, C8 4.7 dB, 5.1 dB, 5.5 dB, 5.9 dB
C9, C10, C11, C12 5.1 dB, 5.5 dB, 5.9 dB, 6.3 dB
C13, C14, C15, C16 5.5 dB, 5.9 dB, 6.3 dB, 6.7 dB
Insertion loss typical value (port dependent)
C1, C2, C3, C4 1.7 dB, 1.9 dB, 2.1 dB, 2.4 dB
C5, C6, C7, C8 1.8 dB, 2 dB, 2.3 dB, 2.5 dB
C9, C10, C11, C12 1.9 dB, 2.1 dB, 2.4 dB, 2.7 dB
C13, C14, C15, C16 2.2 dB, 2.5 dB, 2.8 dB, 2.9 dB
Insertion loss network port to Preamp-T < 1.5 dB

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Isolation for adjacent channels > 30 dB
Directivity > 50 dB
Return loss network port > 40 dB
Return loss Preamp-T > 40 dB
Passband width 250 pm (31.25 GHz)
Latency Preamp-T to Cx-D < 150 ns
Latency network port to Preamp-R < 30 ns

598 Module and System Specification


Chapter 9 Optical Filter Modules

16CSM-#D33-#D64-SFx
The 16CSM-#D33-#D64-SFx is a bi-directional channel splitter and combiner
for DWDM in single-fiber point-to-point configurations. It includes a combination
of specific channel and channel group MUX/DEMUX filters that handle the
combining/splitting of individual channels within the L band (#D33 to #D64)
into/from the full duplex network signal.
Table 1038 provides general information about the module and its environment.

Table 1038: General Information


Equipment type 16CSM-SF-D
First release 8.1
Width 16 HP
Height 5 HU
Weight 1.66 kg (3.7 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption 1.2 W
Maximum RAM consumption on NCU 53 Kbytes
MTBF at 25°C ambient temperature 3,607,113 h
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Slot positions SH9HU: 3...15


SH7HU, SH7HU-R: 3...15

Table below contains information about the optical connector and fiber type.

Table 1039: Optical Interfaces


Number of client ports 16
Number of network ports 1
Number of other ports 1
Optical connector type LC
Fiber type SM G.652

This table provides information about the optical characteristics of the


multiplexer.

Table 1040: Optical Characteristics - Multiplexer


Insertion loss Cx-M to Booster-T (port dependent)
C1, C2, C3, C4 6.7 dB, 6.3 dB, 5.9 dB, 5.5 dB
C5, C6, C7, C8 6.3 dB, 5.9 dB, 5.5 dB, 5.1 dB
C9, C10, C11, C12 5.9 dB, 5.5 dB, 5.1 dB, 4.7 dB
C13, C14, C15, C16 5.5 dB, 5.1 dB, 4.7 dB, 4.3 dB
Insertion loss typical value (port dependent)
C1, C2, C3, C4 2.9 dB, 2.7 dB, 2.4 dB, 2.3 dB
C5, C6, C7, C8 2.6 dB, 2.4 dB, 2.3 dB, 2.1 dB
C9, C10, C11, C12 2.4 dB, 2.2 dB, 2 dB, 1.7 dB
C13, C14, C15, C16 2.4 dB, 2.1 dB, 1.8 dB, 1.7 dB

Module and System Specification 599


16CSM-#D33-#D64-SFx

Table 1040: Optical Characteristics - Multiplexer


Directivity > 50 dB
Insertion loss Booster-R to network port < 1.5 dB
Return loss network port > 40 dB
Return loss Booster-T > 40 dB
Passband width 250 pm (31.25 GHz)
Latency Cx-M to Booster-R < 150 ns
Latency Booster-T to network port < 30 ns

This table shows information about the optical characteristics of the


demultiplexer.

Table 1041: Optical Characteristics - Demultiplexer


Insertion loss Preamp-R to Cx-D (port dependent)
C1, C2, C3, C4 4.3 dB, 4.7 dB, 5.1 dB, 5.5 dB
C5, C6, C7, C8 4.7 dB, 5.1 dB, 5.5 dB, 5.9 dB
C9, C10, C11, C12 5.1 dB, 5.5 dB, 5.9 dB, 6.3 dB
C13, C14, C15, C16 5.5 dB, 5.9 dB, 6.3 dB, 6.7 dB
Insertion loss typical value (port dependent)
C1, C2, C3, C4 1.7 dB, 1.9 dB, 2.1 dB, 2.4 dB
C5, C6, C7, C8 1.8 dB, 2 dB, 2.3 dB, 2.5 dB
C9, C10, C11, C12 1.9 dB, 2.1 dB, 2.4 dB, 2.7 dB
C13, C14, C15, C16 2.2 dB, 2.5 dB, 2.8 dB, 2.9 dB
Insertion loss network port to Preamp-T < 1.5 dB

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Isolation for adjacent channels > 30 dB
Directivity > 50 dB
Return loss > 40 dB
Passband width 250 pm (31.25 GHz)
Latency Preamp-T to Cx-D < 150 ns
Latency network port to Preamp-R < 30 ns

600 Module and System Specification


Chapter 9 Optical Filter Modules

OSFM+#1490-SFA
The OSFM+#1490-SFA (optical supervisory channel filter module - single-fiber
working, location A) adds the OSC #1490 to and drops the OSC #1510 from the
DWDM spectrum on the single network fiber while passing through the DWDM
spectrum.
This module can only be used in conjunction with the complemental
OSFM+#1510-SFB installed on the other side of the communication link.
Table 1042 provides general information about the module and its environment.

Table 1042: General Information


Equipment type OSFM-SF
First release 8.1
Width 4 HP
Height 5 HU
Weight 490 g (1.1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Power consumption 1.2 W


Maximum RAM consumption on 33 Kbytes
NCU
MTBF at 25°C ambient temperature 28,851,702 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

Table below contains information about the optical connector and fiber type.

Table 1043: Interfaces


Number of client ports 1
Number of upgrade ports 1
Number of network ports 1
Optical connector type LC
Fiber type SM G.652

Module and System Specification 601


OSFM+#1490-SFA

This table provides information about the optical characteristics of the


multiplexer.

Table 1044: Optical Characteristics - Multiplexer


Insertion loss max. value 1.5 dB for 1490 nm add port
1.3 dB for upgrade port
Insertion loss typical value 1 dB for 1490 nm add port
1 dB for upgrade port
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 1484.5 nm to 1497.5 nm
Latency < 60 ns

This table shows information about the optical characteristics of the


demultiplexer.

Table 1045: Optical Characteristics - Demultiplexer


Insertion loss max. value 1.5 dB for 1510 nm drop port
1.5 dB for upgrade port
Insertion loss typical value 1 dB for 1510 nm add port
1 dB for upgrade port
Isolation > 30 dB for drop port

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 1504.5 nm to 1517.5 nm
Latency < 60 ns

602 Module and System Specification


Chapter 9 Optical Filter Modules

OSFM+#1510-SFB
The OSFM+#1510-SFB (optical supervisory channel filter module - single-fiber
working, location B) adds the OSC #1510 to and drops the OSC #1490 from the
DWDM spectrum on the single network fiber while passing through the DWDM
spectrum.
This module can only be used in conjunction with the complemental
OSFM+#1490-SFA installed on the other side of the communication link.
Table 1046 provides general information about the module and its environment.

Table 1046: General Information


Equipment type OSFM-SF
First release 8.1
Width 4 HP
Height 5 HU
Weight 490 g (1.1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption 1.2 W
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Maximum RAM consumption on NCU 33 Kbytes


MTBF at 25°C ambient temperature 28,851,702 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical connector and fiber
type.

Table 1047: Interfaces


Number of client ports 1
Number of upgrade ports 1
Number of network ports 1
Optical connector type LC
Fiber type SM G.652

This table provides information about the optical characteristics of the


multiplexer.

Table 1048: Optical Characteristics - Multiplexer


Insertion loss max. value 1.5 dB for 1510 nm add port
1.3 dB for upgrade port
Insertion loss typical value 0.7 dB for 1510 nm add port
0.5 dB for upgrade port

Module and System Specification 603


OSFM+#1510-SFB

Table 1048: Optical Characteristics - Multiplexer (Continued)


Directivity > 50 dB
Optical return loss > 40 dB
Passband width 1504.5 nm to 1517.5 nm
Latency < 60 ns

This table shows information about the optical characteristics of the


demultiplexer.

Table 1049: Optical Characteristics - Demultiplexer


Insertion loss max. value 1.5 dB for 1490 nm drop port
1.5 dB for upgrade port
Insertion loss typical value 0.8 dB for 1490 nm drop port
0.6 dB for upgrade port
Isolation > 30 dB for drop port
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 1484.5 nm to 1497.5 nm
Latency < 60 ns

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

604 Module and System Specification


Chapter 9 Optical Filter Modules

2ABSM-#C1470-#C1610
The 2ABSM-#C1470-#C1610 is an optical 2-port CWDM subband splitter
module.
The module serves as combiner and splitter of two groups of multiplexed
CWDM channels. One group comprises the channels #C1470, #C1490,
#C1590 and #C1610 with the corresponding center wavelengths 1471 nm, 
1491 nm, 1591 nm and 1611 nm. The other group includes the channels
#C1510, #C1530, #C1550 and #C1570 with the center wavelengths 1511 nm,
1531 nm, 1551 nm and 1571 nm.
The 2ABSM-#C1470-#C1610 incorporates a combination of specific MUX and
DEMUX band filters. These filters multiplex/demultiplex the wavelength bands
of the two groups of channels into/from one full duplex signal carried by the
network fiber pair.
Table 1050 provides general information about the module and its environment.

Table 1050: General Information


Equipment type 2ABSM-C
First release 7.0
Width 4 HP
Height 5 HU
Weight 510 g (1.1 lbs)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Environmental conditions Telcordia SR-3580 level 3 (NEBS),


ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 4,761,905 h
Power consumption 1.2 W
Maximum RAM consumption on NCU 21 Kbytes
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical interfaces.

Table 1051: Optical Interfaces


Number of client ports (duplex) 2
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

This table provides information about the optical characteristics of the


multiplexer.

Table 1052: Optical Characteristics - Multiplexer


Insertion loss max. value 1.5 dB (all ports)
Insertion loss typical value 0.5 dB (all ports)

Module and System Specification 605


2ABSM-#C1470-#C1610

Table 1052: Optical Characteristics - Multiplexer (Continued)


Directivity > 50 dB
Optical return loss > 40 dB
Latency < 30 ns

The following table contains information about the optical characteristics of the
demultiplexer.

Table 1053: Optical Characteristics - Demultiplexer


Insertion loss max. value 1.7 dB (all ports)
Insertion loss typical value 0.8 dB (all ports)
Directivity > 50 dB
Optical return loss > 40 dB
Isolation > 30 dB
Latency < 30 ns

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

606 Module and System Specification


Chapter 9 Optical Filter Modules

3BSM-#G1310-#C1610
The 3BSM-#G1310-#C1610 is an optical CWDM band splitter module with gray
interface at 1310 nm .
The module serves as combiner and splitter of two groups of multiplexed
CWDM channels. One group comprises the channels #C1470, #C1490,
#C1590 and #C1610 with the corresponding center wavelengths 1471 nm, 1491
nm, 1591 nm and 1611 nm. The other group includes the channels #C1510,
#C1530, #C1550 and #C1570 with the center wavelengths 1511 nm, 1531 nm,
1551 nm and 1571 nm. In addition, it enables the transmission of a gray channel
(#G1310) over the CWDM network without having to upgrade existing
infrastructure and without affecting running services.
The respective wavelengths are
1471 nm, 1491 nm, 1591 nm and 1611 nm for one channel group,
1511 nm, 1531 nm, 1551 nm, 1571 nm for the other channel group and
1310 nm.
Table 1054 provides general information about the module and its environment.

Table 1054: General Information


Equipment type 3BSM-C
First release 7.0
Width 4 HP
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Height 5 HU
Weight 530 g (1.17 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 2,500,000 h
Power consumption 1.2 W
Maximum RAM consumption on 20 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical connector and fiber
type.

Table 1055: Optical Interfaces


Number of client ports (duplex) 3
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

Module and System Specification 607


3BSM-#G1310-#C1610

This table provides information about the optical characteristics of the


multiplexer.

Table 1056: Optical Characteristics - Multiplexer


Insertion loss max. value
1310 nm 1.5 dB (port C1)
1470 nm, 1490 nm, 1590 nm, 1610 nm 1.8 dB (port C2)
1510 nm, 1530 nm, 1550 nm, 1570 nm 1.8 dB (port C3)
Insertion loss typical value
1310 nm 0.8 dB (port C1)
1470 nm, 1490 nm, 1590 nm, 1610 nm 0.9 dB (port C2)
1510 nm, 1530 nm, 1550 nm, 1570 nm 0.7 dB (port C3)
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 75 ns

This table shows information about the optical characteristics of the


demultiplexer.

Table 1057: Optical Characteristics - Demultiplexer


Insertion loss max. value
1310 nm 1.7 dB (port C1)
1470 nm, 1490 nm, 1590 nm, 1610 nm 2.1 dB (port C2)
1510 nm, 1530 nm, 1550 nm, 1570 nm 2.1 dB (port C3)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Insertion loss typical value
1310 nm 1 dB (port C1)
1470 nm, 1490 nm, 1590 nm, 1610 nm 1.1 dB (port C2)
1510 nm, 1530 nm, 1550 nm, 1570 nm 1 dB (port C3)
Directivity > 50 dB
Optical return loss > 40 dB
Isolation > 30 dB
Latency < 75 ns

608 Module and System Specification


Chapter 9 Optical Filter Modules

4CSM-#Cxxxx-#Cyyyy
The 4CSM-#Cxxxx-#Cyyyy is an optical 4-port CWDM channel splitter and
combiner module. It contains a combination of MUX and DEMUX channel filters
for the above mentioned groups of channels. One group comprises the
channels #C1470, #C1490, #C1590 and #C1610 with the corresponding center
wavelengths 1471 nm, 1491 nm, 1591 nm and 1611 nm. The other group
includes the channels #C1510, #C1530, #C1550 and #C1570 with the center
wavelengths 1511 nm, 1531 nm, 1551 nm and 1571 nm.
Table 1058 provides general information about the module and its environment.

Table 1058: General Information


Equipment type 4CSM-C
First release 7.0
Width 4 HP
Height 5 HU
Weight 600 g (1.3 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Power consumption 1.2 W


Maximum RAM consumption on NCU 35 Kbytes
MTBF at 25°C ambient temperature 10,204,082 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical interfaces.

Table 1059: Optical Interfaces


Number of client ports (duplex) 4
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

Module and System Specification 609


4CSM-#Cxxxx-#Cyyyy

This table shows information about the optical characteristics of the multiplexer.

Table 1060: Optical Characteristics - Multiplexer


Insertion loss max. value
1471 nm, 1511 nm 1.4 dB (port C1)
1491 nm, 1531 nm 1.6 dB (port C2)
1551 nm, 1591 nm 1.8 dB (port C3)
1571 nm, 1611 nm 2 dB (port C4)
Insertion loss typical value
1471 nm, 1511 nm 0.7 dB (port C1)
1491 nm, 1531 nm 0.9 dB (port C2)
1551 nm, 1591 nm 1.1 dB (port C3)
1571 nm, 1611 nm 1.4 dB (port C4)
Passband width 13 nm according to ITU-T G.694
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 75 ns

This table shows information about the optical characteristics of the


demultiplexer.

Table 1061: Optical Characteristics - Demultiplexer


Insertion loss max. value
1471 nm, 1511 nm 2 dB (port C1)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
1491 nm, 1531 nm 1.8 dB (port C2)
1551 nm, 1591 nm 1.6 dB (port C3)
1571 nm, 1611 nm 1.4 dB (port C4)
Insertion loss typical value
1471 nm, 1511 nm 1.4 dB (port C1)
1491 nm, 1531 nm 1.1 dB (port C2)
1551 nm, 1591 nm 1 dB (port C3)
1571 nm, 1611 nm 0.7 dB (port C4)
Passband width 13 nm according to ITU-T G.694
Isolation for adjacent channels > 30 dB
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 30 ns

610 Module and System Specification


Chapter 9 Optical Filter Modules

8CSM+#C1470-#C1610
The 8CSM+#C1470-#C1610 is an optical 8-port CWDM channel splitter module
with upgrade port.
The module allows access to a single gray channel (#G1310) from a network
fiber and splits/combines the entire CWDM channel spectrum which ranges
from #C1470 to #C1610.
The 8CSM+#C1470-#C1610 contains a combination of specific add/drop optical
filters and MUX/DEMUX filters.
Table 1062 provides general information about the module and its environment.

Table 1062: General Information


Equipment type 8CSMU-C
First release 7.1
Width 8 HP
Height 5 HU
Weight 810 g (1.8 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IEC IP20. Use in a pollution degree 2
60529 environment and indoor controlled
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

office environments only.


Power consumption 1.2 W
Maximum RAM consumption on NCU 40 Kbytes
MTBF at 25°C ambient temperature 3,571,429 h
Slot positions SH9HU: 3...17
SH7HU, SH7HU-R: 3...17
SH1HU: 1

Table below contains information about the optical connector and fiber type.

Table 1063: Optical Interfaces


Number of client ports 8
Number of upgrade ports (1310 nm) 1
Number of network ports 1
Optical connector type LC
Fiber type SM G.652

Module and System Specification 611


8CSM+#C1470-#C1610

This table shows information about the optical characteristics of the multiplexer.

Table 1064: Optical Characteristics - Multiplexer


Insertion loss client ports max. value
1471 nm, 3.7 dB (port C1)
1491 nm, 3.5 dB (port C2)
1511 nm, 3.3 dB (port C3)
1531 nm, 3.1 dB (port C4)
1551 nm, 2.9 dB (port C5)
1571 nm, 2.7 dB (port C6)
1591 nm, 2.5 dB (port C7)
1611 nm 2.3 dB (port C8)
Insertion loss client ports typ. value
1471 nm, 1.9 dB (port C1)
1491 nm, 1.8 dB (port C2)
1511 nm, 1.5 dB (port C3)
1531 nm, 1.4 dB (port C4)
1551 nm, 1.2 dB (port C5)
1571 nm, 0.95 dB (port C6)
1591 nm, 0.85 dB (port C7)
1611 nm 0.7 dB (port C8)
Insertion loss upgrade port 1310 nm 1.5 dB
max. value
Insertion loss upgrade port 1310 nm 0.7 dB

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
typical value
Passband width client ports 13 nm according to ITU-T G.694
Passband width upgrade port 77 nm
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 105 ns

612 Module and System Specification


Chapter 9 Optical Filter Modules

Table below shows information about the optical characteristics of the


demultiplexer.

Table 1065: Optical Characteristics - Demultiplexer


Insertion loss client ports max. value
1471 nm, 2.3 dB (port C1)
1491 nm, 2.5 dB (port C2)
1511 nm, 2.7 dB (port C3)
1531 nm, 2.9 dB (port C4)
1551 nm, 3.1 dB (port C5)
1571 nm, 3.3 dB (port C6)
1591 nm, 3.5 dB (port C7)
1611 nm 3.7 dB (port C8)
Insertion loss client ports typ. value
1471 nm, 0.6 dB (port C1)
1491 nm, 0.8 dB (port C2)
1511 nm, 0.95 dB (port C3)
1531 nm, 1.1 dB (port C4)
1551 nm, 1.25 dB (port C5)
1571 nm, 1.45 dB (port C6)
1591 nm, 1.7 dB (port C7)
1611 nm 1.8 dB (port C8)
Insertion loss upgrade port 1310 nm 3.2 dB
max. value
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Insertion loss upgrade port 1310 nm 2.1 dB


typical value
Passband width 13 nm according to ITU-T G.694
Passband width upgrade port 77 nm
Isolation for adjacent channels > 55 dB
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 105 ns

Module and System Specification 613


1CSM+#G1310

1CSM+#G1310
The 1CSM+#G1310 is an optical CWDM Single Channel Splitter Module with
1310-nm connectivity. The module allows access to a single gray channel
(#G1310) from a network fiber while passing CWDM/DWDM channels. The
1CSM+#G1310 contains a combination of specific add/drop optical filters.
These filters perform the add/drop function on the pre-defined wavelengths
around 1310 nm.
Table 1066 provides general information about the module and its environment.

Table 1066: General Information


Equipment type 1CSMU-G
First release 7.0
Width 4 HP
Height 5 HU
Weight 510 g (1.1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption 1.2 W

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Maximum RAM consumption on 36 Kbytes
NCU
MTBF at 25°C ambient temperature 4,761,905 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical interfaces.

Table 1067: Optical Interfaces


Number of client ports (duplex) 1
Number of upgrade ports (duplex) 1
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

This table shows information about the optical characteristics of the multiplexer.

Table 1068: Optical Characteristics - Multiplexer


Number of optical systems 1
Insertion loss max. value 1.5 dB for add port, 1 dB for upgrade port
Insertion loss typical value 0.8 dB for drop port, 0.6 for upgrade port
Passband width 1260 ... 1360nm
Directivity > 50 dB

614 Module and System Specification


Chapter 9 Optical Filter Modules

Table 1068: Optical Characteristics - Multiplexer (Continued)


Optical return loss > 40 dB
Latency < 30 ns

This table shows information about the optical characteristics of the


demultiplexer.

Table 1069: Optical Characteristics - Demultiplexer


Number of optical systems 1
Insertion loss max. value 1.5 dB for drop port, 1.5 dB for upgrade
port
Insertion loss typical value 1.2 dB for drop port, 0.6 for upgrade port
Passband width 1260 ... 1360nm
Isolation > 55 dB for drop port and upgrade port
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 30 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 615


1CSM+#Cxxxx

1CSM+#Cxxxx
The 1CSM+#Cxxxx is an optical single channel CWDM splitter and combiner
module. On a per-wavelength basis, it allows access to a specific channel from
a network fiber while passing the remaining channel spectrum. The
1CSM+#Cxxxx contains a combination of specific add/drop optical filters. These
filters add/drop a specific channel to/out of the CWDM channel spectrum while
reflecting all other channels onto the upgrade port according to the CWDM
wavelengths grid.
There are 8 separate modules:
1CSM+#C1470, 1CSM+#C1490, 1CSM+#C1510, 1CSM+#C1530,
1CSM+#C1550, 1CSM+#C1570, 1CSM+#C1590, 1CSM+#C1610.
The respective center wavelengths are 1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm and 1611 nm.
Table 1070 provides general information about the module and its environment.

Table 1070: General Information


Equipment type 1CSMU-C
First release 7.0
Width 4 HP
Height 5 HU
Weight 490 g (1 lbs)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption 1.2 W
Maximum RAM consumption on 32 Kbytes
NCU
MTBF at 25°C ambient temperature 4,672,897 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical connector and fiber
type.

Table 1071: Optical Interfaces


Number of client ports (duplex) 1
Number of upgrade ports (duplex) 1
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

616 Module and System Specification


Chapter 9 Optical Filter Modules

This table shows information about the optical characteristics of the multiplexer.

Table 1072: Optical Characteristics - Multiplexer


Number of optical systems 1
Insertion loss max. value 1.5 dB for add port, 1 dB for upgrade port
Insertion loss typical value 0.5 dB for add port, 0.5 dB for upgrade port
Passband width 13 nm according to ITU-T G.694
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 30 ns

This table shows information about the optical characteristics of the


demultiplexer.

Table 1073: Optical Characteristics - Demultiplexer


Number of optical systems 1
Insertion loss max. value 1.5 dB for drop port, 1.5 dB for upgrade port
Insertion loss typical value 0.8 dB for add port, 0.5 dB for upgrade port
Passband width 13 nm according to ITU-T G.694
Isolation > 55 dB for drop port,
> 12 dB for upgrade port
Directivity > 50 dB
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Optical return loss > 40 dB


Latency < 30 ns

Module and System Specification 617


5GSM/P-#19590-#19200-DM

5GSM/P-#19590-#19200-DM
The 5GSM/P-#19590-#19200-DM is a passive 5-port DWDM channel group
splitter and combiner module with monitoring port for dual power level
monitoring. It is designed for use in an SH1HU/PASSIVE/FT shelf only.

The module is completely passive and is not detectable for inventory


retrieval. The network element does not support inventory
PS

management of this module, and is transparent to the Network


Note Manager and Control Plane applications.

The 5GSM/P-#19590-#19200-DM supports the even channels #19590 through


#19200 of the C band.
Table 1074 provides general information about the module and its environment.

Table 1074: General Information


Equipment type -
First release 10.2
Width 8 HP
Height 5 HU
Weight 850 g (1.9 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ETSI EN 300 019-1-3 Class 3.1,
extended temperature range -25°C to
+70°C with insertion loss penalty
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 14,705,883 h
Power consumption -
Slot positions 1, 3 of SH1HU/PASSIVE/FT only

The following table provides information about the optical interfaces.

Table 1075: Optical Interfaces


Number of client ports 5
Number of monitoring ports 1 (for ingress and egress at network port)
Number of network ports 1
Optical connector type LC
Fiber type SM G.652

618 Module and System Specification


Chapter 9 Optical Filter Modules

This table contains information about optical characteristics of the multiplexer.

Table 1076: Optical Characteristics - Multiplexer


Insertion loss max. value
#19590 - #19520 3.9 dB (port C1)
#19510 - #19440 3.4 dB (port C2)
#19430 - #19360 2.9 dB (port C3)
#19350 - #19280 2.4 dB (port C4)
#19270 - #19200 1.9 dB (port C5)
Insertion loss typ. value
#19590 - #19520 1.95 dB (port C1)
#19510 - #19440 1.87 dB (port C2)
#19430 - #19360 1.60 dB (port C3)
#19350 - #19280 1.47 dB (port C4)
#19270 - #19200 1.3 dB (port C5)
Insertion loss monitoring port max. value
(#19590 - #19200) 16.5 dB
Insertion loss penalty at all interfaces for 0.5 dB
temperature range -25°C to +70°C
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 105 ns

This table shows information about optical characteristics of the demultiplexer.


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 1077: Optical Characteristics - Demultiplexer


Insertion loss max. value
#19590 - #19520 1.9 dB (port C1)
#19510 - #19440 2.4 dB (port C2)
#19430 - #19360 2.9 dB (port C3)
#19350 - #19280 3.4 dB (port C4)
#19270 - #19200 3.9 dB (port C5)
Insertion loss typ. value
#19590 - #19520 1.23 dB (port C1)
#19510 - #19440 1.32 dB (port C2)
#19430 - #19360 1.67 dB (port C3)
#19350 - #19280 1.87 dB (port C4)
#19270 - #19200 2.05 dB (port C5)
Insertion loss monitoring port max. value
#19590 - #19520 19 dB (port C1)
#19510 - #19440 18.5 dB (port C2)
#19430 - #19360 18 dB (port C3)
#19350 - #19280 17.5 dB (port C4)
#19270 - #19200 17 dB (port C5)
Insertion loss penalty at all interfaces for 0.5 dB
temperature range -25°C to +70°C
Directivity > 50 dB
Optical return loss > 40 dB
Isolation adjacent bands > 15 dB
Latency < 105 ns

Module and System Specification 619


8CSM/P-#C1470-#C1610-DM

8CSM/P-#C1470-#C1610-DM
The 8CSM/P-#C1470-#C1610-DM is a passive 8-port CWDM channel splitter
module with monitoring port for dual power level monitoring. It is intended for
use in an SH1HU/PASSIVE/FT shelf only.

This device is passive and not detected or visible through system


PS

inventory. The module is not visible by inventory management,


Control Plane, or the Network Manager system.
Note

Table 1078 provides general information about the module and its environment.

Table 1078: General Information


Equipment type -
First release 8.2
Width 8 HP
Height 5 HU
Weight 810 g (1.8 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1,
extended temperature range -25°C to
+70°C with insertion loss penalty

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption -
MTBF at 25°C ambient temperature 3,448,276 h
Slot positions 1, 3 of SH1HU/PASSIVE/FT only

The following table contains information about the optical interfaces.

Table 1079: Optical Interfaces


Number of client ports (duplex) 8
Number of monitoring ports 1 (for ingress and egress at the
(1310 nm, duplex) network port)
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

620 Module and System Specification


Chapter 9 Optical Filter Modules

This table shows information about the optical characteristics of the multiplexer.

Table 1080: Optical Characteristics - Multiplexer


Insertion loss client ports max. value
1471 nm, 1511 nm, 1.6 dB (port C1), 1.8 dB (port C3)
1491 nm, 1531 nm, 2 dB (port C2), 2.2 dB (port C4)
1551 nm, 1591 nm, 2.4 dB (port C5), 2.6 dB (port C7)
1571 nm, 1611 nm 2.8 dB (port C6), 3 dB (port C8)
Insertion loss client ports typ. value
1471 nm, 1511 nm, 1.36 dB (port Cx)
1491 nm, 1531 nm,
1551 nm, 1591 nm,
1571 nm, 1611 nm
Insertion loss monitoring port max. value 17.8 dB
Insertion loss penalty at all interfaces for 0.5 dB
temperature range -25°C to +70°C
Passband width client ports 13 nm according to ITU-T G.694
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 150 ns

This table shows information about the optical characteristics of the


demultiplexer.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 1081: Optical Characteristics - Demultiplexer


Insertion loss client ports max. value
1471 nm, 1511 nm, 3 dB (port C1), 2.8 dB (port C3)
1491 nm, 1531 nm, 2.6 dB (port C2), 2.4 dB (port C4)
1551 nm, 1591 nm, 2.2 dB (port C5), 2 dB (port C7)
1571 nm, 1611 nm 1.8 dB (port C6), 1.6 dB (port C8)
Insertion loss client ports typ. value
1471 nm, 1511 nm, 1.38 dB (port Cx)
1491 nm, 1531 nm,
1551 nm, 1591 nm,
1571 nm, 1611 nm
Insertion loss monitoring port max. value 15.5 dB
Insertion loss penalty at all interfaces for 0.5 dB
temperature range -25°C to +70°C
Passband width 13 nm according to ITU-T G.694
Isolation for adjacent channels > 30 dB
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 150 ns

Module and System Specification 621


2BSM/P-#C1270-#C1610-DM

2BSM/P-#C1270-#C1610-DM
The 2BSM/P-#C1270-#C1610-DM is a passive 2-port CWDM band splitter
module with gray interface at 1310 nm and monitoring port for dual power level
monitoring.

This device is passive and not detected or visible through system


PS

inventory. The module is not visible by inventory management,


Control Plane, or the Network Manager system.
Note

The module allows access either to additional CWDM channels in the range
between C#1270 and C#1450 or to gray channel (#G1310) from a network fiber
while passing through the CWDM channels (#1470 - #1610) used by ADVA
Optical Networking.
Table 1082 provides general information about the module and its environment.

Table 1082: General Information


Equipment type -
First release 8.2
Width 4 HP
Height 5 HU

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Weight 530 g (1.17 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1,
extended temperature range -25°C to
+70°C with insertion loss penalty
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 4,347,826 h
Power consumption -
Slot positions 1 ... 4 in an SH1HU/PASSIVE/FT only

The following table provides information about the optical interfaces.

Table 1083: Optical Interfaces


Number of client ports 2
Number of monitoring ports 1 (for ingress and egress at network
port)
Number of network ports 1
Optical connector type LC
Fiber type SM G.652

622 Module and System Specification


Chapter 9 Optical Filter Modules

This table contains information about the optical characteristics of the


multiplexer.

Table 1084: Optical Characteristics - Multiplexer


Insertion loss max. value
1264.5 nm - 1457.5 nm 2 dB (port C1)
1464.5 nm - 1617.5 nm 1.8 dB (port C2)
Insertion loss typ. value
1264.5 nm - 1457.5 nm 0.95 dB (port C1)
1464.5 nm - 1617.5 nm 0.85 dB (port C2)
Insertion loss monitoring port max.
value (1310 nm - 1610 nm) 16.5 dB
Insertion loss penalty at all 0.5 dB
interfaces for temperature range
-25°C to +70°C
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 30 ns

This table shows information about the optical characteristics of the


demultiplexer

Table 1085: Optical Characteristics - Demultiplexer


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Insertion loss max. value


1264.5 nm - 1457.5 nm 2.2 dB (port C1)
1464.5 nm - 1617.5 nm 2.2 dB (port C2)
Insertion loss typ. value
1264.5 nm - 1457.5 nm 1.1 dB (port C1)
1464.5 nm - 1617.5 nm 1.05 dB (port C2)
Insertion loss monitoring port max.
value (1310 nm - 1610 nm) 15.5 dB
Insertion loss penalty at all 0.5 dB
interfaces for temperature range
-25°C to +70°C
Directivity > 50 dB
Optical return loss > 40 dB
Isolation > 30 dB
Latency < 30 ns

Module and System Specification 623


8CSM/P+#C1470-#C1610-DM

8CSM/P+#C1470-#C1610-DM
The 8CSM/P+#C1470-#C1610-DM is a passive 8-port CWDM channel splitter
module with upgrade port and dual monitoring points for external Optical
Spectrum Analyzers (OSA). It is intended for use in an SH1HU/PASSIVE/FT
shelf only.

This device is passive and not detected or visible through system


PS

inventory. The module is not visible by inventory management,


Control Plane, or the Network Manager system.
Note

Table 1086 provides general information about the module and its environment.

Table 1086: General Information


Equipment type -
First release 9.1
Width 8 HP
Height 5 HU
Weight 810 g (1.8 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1,
temperature range -5°C to +65°C

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
without insertion loss penalty,
extended temperature range -25°C to
+70°C with insertion loss penalty
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption -
MTBF at 25°C ambient temperature 5,344,418 h
Slot positions 1, 3 of SH1HU/PASSIVE/FT only

The following table contains information about the optical interfaces.

Table 1087: Optical Interfaces


Number of client ports (duplex) 8
Number of upgrade ports (duplex) 1
Number of monitoring ports 1 (for ingress and egress at network
(1310 nm, duplex) port)
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

624 Module and System Specification


Chapter 9 Optical Filter Modules

This table shows information about the optical characteristics of the multiplexer.

Table 1088: Optical Characteristics - Multiplexer


Insertion loss client and upgrade ports 2.5 dB
max. value
Insertion loss client and upgrade ports 1.26 dB
typ. value
Insertion loss monitoring port max. value 17.5 dB
Insertion loss penalty at all interfaces for 0.3 dB
extended temperature range -25°C to
+70°C
Passband width client ports 13 nm according to ITU-T G.694
Passband width upgrade port 1264.5 nm to 1457.5 nm
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 40 ns

This table shows information about the optical characteristics of the


demultiplexer.

Table 1089: Optical Characteristics - Demultiplexer


Insertion loss client and upgrade ports 2.5 dB
max. value
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Insertion loss client and upgrade ports 1.35 dB


typ. value
Insertion loss monitoring port max. value 15 dB
Insertion loss penalty at all interfaces for 0.3 dB
extended temperature range -25°C to
+70°C
Passband width 13 nm according to ITU-T G.694
Isolation for adjacent channels incl. > 30 dB
upgrade channel
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 40 ns

Module and System Specification 625


8CSM/P-#19xxx-#19yyy

8CSM/P-#19xxx-#19yyy
The 8CSM/P-#19xxx-#19yyy is a passive 8-port DWDM channel splitter and
combiner module. It is designed for use in an SH1HU/PASSIVE/FT shelf.

The module is completely passive and is not detectable for inventory


retrieval. The network element does not support inventory
PS

management of this module, and is transparent to the Network


Note Manager and Control Plane applications.

There are five separate modules in the C band covering DWDM channels:
8CSM/P-#19590-#19520, 8CSM/P-#19510-#19440, 8CSM/P-#19430-#19360,
8CSM/P-#19350-#19280, 8CSM/P-#19270-#19200
Table 1090 provides general information about the module and its environment.

Table 1090: General Information


Equipment type 8CSMP
First release 10.2
Width 8 HP
Height 5 HU
Weight 800 g (1.8 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ETSI EN 300 019-1-3 Class 3.1,
extended temperature range -25°C to
+70°C with insertion loss penalty
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption -
MTBF at 25°C ambient temperature 3,649,635 h
Slot positions 1, 3 of SH1HU/PASSIVE/FT only

The following table contains information about the optical interfaces.

Table 1091: Optical Interfaces


Number of client ports (duplex) 8
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

626 Module and System Specification


Chapter 9 Optical Filter Modules

This table shows information about the optical characteristics of the multiplexer.

Table 1092: Optical Characteristics - Multiplexer


Insertion loss max. value (port dependent)
#19590, #19510, #19430, #19350, #19270 3.7 dB (port C1)
#19580, #19500, #19420, #19340, #19260 3.5 dB (port C2)
#19570, #19490, #19410, #19330, #19250 3.3 dB (port C3)
#19560, #19480, #19400, #19320, #19240 3 dB (port C4)
#19550, #19470, #19390, #19310, #19230 2.7 dB (port C5)
#19540, #19460, #19380, #19300, #19220 2.4 dB (port C6)
#19530, #19450, #19370, #19290, #19210 2.1 dB (port C7)
#19520, #19440, #19360, #19280, #19200 1.8 dB (port C8)
Insertion loss typ. value (port dependent)
#19590, #19510, #19430, #19350, #19270 1.9 dB (port C1)
#19580, #19500, #19420, #19340, #19260 1.8 dB (port C2)
#19570, #19490, #19410, #19330, #19250 1.5 dB (port C3)
#19560, #19480, #19400, #19320, #19240 1.4 dB (port C4)
#19550, #19470, #19390, #19310, #19230 1.2 dB (port C5)
#19540, #19460, #19380, #19300, #19220 0.95 dB (port C6)
#19530, #19450, #19370, #19290, #19210 0.85 dB (port C7)
#19520, #19440, #19360, #19280, #19200 0.7 dB (port C8)
Insertion loss penalty at all interfaces for 0.5 dB
temperature range -25°C to +70°C
Passband width client ports 250 pm (31.25 GHz)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Directivity > 50 dB
Optical return loss > 40 dB
Latency < 135 ns

This table shows information about the optical characteristics of the


demultiplexer.

Table 1093: Optical Characteristics - Demultiplexer


Insertion loss max. value (port dependent)
#19590, #19510, #19430, #19350, #19270 1.8 dB (port C1)
#19580, #19500, #19420, #19340, #19260 2.1 dB (port C2)
#19570, #19490, #19410, #19330, #19250 2.4 dB (port C3)
#19560, #19480, #19400, #19320, #19240 2.7 dB (port C4)
#19550, #19470, #19390, #19310, #19230 3 dB (port C5)
#19540, #19460, #19380, #19300, #19220 3.3 dB (port C6)
#19530, #19450, #19370, #19290, #19210 3.5 dB (port C7)
#19520, #19440, #19360, #19280, #19200 3.7 dB (port C8)
Insertion loss typ. value (port dependent)
#19590, #19510, #19430, #19350, #19270 0.6 dB (port C1)
#19580, #19500, #19420, #19340, #19260 0.8 dB (port C2)
#19570, #19490, #19410, #19330, #19250 0.95 dB (port C3)
#19560, #19480, #19400, #19320, #19240 1.1 dB (port C4)
#19550, #19470, #19390, #19310, #19230 1.25 dB (port C5)
#19540, #19460, #19380, #19300, #19220 1.45 dB (port C6)
#19530, #19450, #19370, #19290, #19210 1.7 dB (port C7)
#19520, #19440, #19360, #19280, #19200 1.8 dB (port C8)

Module and System Specification 627


8CSM/P-#19xxx-#19yyy

Table 1093: Optical Characteristics - Demultiplexer (Continued)


Insertion loss penalty at all interfaces for 0.5 dB
temperature range -25°C to +70°C
Passband width 250 pm (31.25 GHz)
Isolation for adjacent channels > 30 dB
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 135 ns

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

628 Module and System Specification


Chapter 9 Optical Filter Modules

8CSM/P-#C1270-#C1450
The 8CSM/P-#C1270-#C1450 is a passive 8-port CWDM channel splitter
module with monitoring port. It is intended for use in an SH1HU/PASSIVE/FT
shelf only.

This device is passive and not detected or visible through system


PS

inventory. The module is not visible by inventory management,


Control Plane, or the Network Manager system.
Note

Table 1094 provides general information about the module and its environment.

Table 1094: General Information


Equipment type -
First release 9.1
Width 8 HP
Height 5 HU
Weight 800 g (1.8 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1,
temperature range -5°C to +65°C
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

without insertion loss penalty,


extended temperature range -25°C to
+70°C with insertion loss penalty
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption -
MTBF at 25°C ambient temperature 6,206,896 h
Slot positions 1, 3 of SH1HU/PASSIVE/FT only

The following table contains information about the optical interfaces.

Table 1095: Optical Interfaces


Number of client ports (duplex) 8
Number of monitoring ports 1 (for ingress and egress at network
(1310 nm, duplex) port)
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

This table shows information about the optical characteristics of the multiplexer.

Table 1096: Optical Characteristics - Multiplexer


Insertion loss client ports max. value 2.2 dB
Insertion loss client ports typ. value 1.25 dB

Module and System Specification 629


8CSM/P-#C1270-#C1450

Table 1096: Optical Characteristics - Multiplexer (Continued)


Insertion loss monitoring port max. value 17.5 dB
Insertion loss penalty at all interfaces for 0.3 dB
extended temperature range -25°C to
+70°C
Passband width client ports 13 nm according to ITU-T G.694
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 20 ns

This table shows information about the optical characteristics of the


demultiplexer.

Table 1097: Optical Characteristics - Demultiplexer


Insertion loss client ports max. value 2.2 dB
Insertion loss client ports typ. value 1.18 dB
Insertion loss monitoring port max. value 15.5 dB
Insertion loss penalty at all interfaces for 0.3 dB
extended temperature range -25°C to
+70°C
Passband width 13 nm according to ITU-T G.694
Isolation for adjacent channels > 30 dB
Directivity > 50 dB

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical return loss > 40 dB
Latency < 20 ns

630 Module and System Specification


Chapter 9 Optical Filter Modules

1CSM/P+#Cxxxx
The 1CSM/P+#Cxxxx is a passive optical single channel CWDM splitter and
combiner module with upgrade port. The module contains a combination of
specific add/drop optical filters. These filters add/drop a specific channel to/out
of the CWDM channel spectrum while reflecting all other channels onto the
upgrade port.

This device is passive and not detected or visible through system


PS

inventory. The module is not visible by inventory management,


Control Plane, or the Network Manager system.
Note

There are 8 separate modules:


1CSM/P+#C1470, 1CSM/P+#C1490, 1CSM/P+#C1510, 1CSM/P+#C1530,
1CSM/P+#C1550, 1CSM/P+#C1570, 1CSM/P+#C1590, 1CSM/P+#C1610
For the CWDM wavelength grid, refer to Table 3: CWDM Wavelengths Used by
FSP 3000R7 on p. 59 in the ”Introduction”.
Table 1098 provides general information about the module and its environment.

Table 1098: General Information


Equipment type -
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

First release 9.1


Width 4 HP
Height 5 HU
Weight 490 g (1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1,
extended temperature range -25°C to
+70°C with insertion loss penalty
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption <2W
MTBF at 25°C ambient temperature 4,761,905 h
Slot positions 1 ... 4 of SH1HU/PASSIVE/FT only

Table below contains information about the optical connector and fiber type.

Table 1099: Optical Interfaces


Number of client ports (duplex) 1
Number of upgrade ports (duplex) 1
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

Module and System Specification 631


1CSM/P+#Cxxxx

This table shows information about the optical characteristics of the multiplexer.

Table 1100: Optical Characteristics - Multiplexer


Number of optical systems 1
Insertion loss max. value 1.5 dB for add port, 1.2 dB for upgrade port
Insertion loss typical value 0.5 dB for add port, 0.5 dB for upgrade port
Insertion loss penalty at all 0.5 dB
interfaces for temperature
range -25°C to +70°C
Passband width 13 nm according to ITU-T G.694
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 30 ns

This table shows information about the optical characteristics of the


demultiplexer.

Table 1101: Optical Characteristics - Demultiplexer


Number of optical systems 1
Insertion loss max. value 1.5 dB for drop port, 1.2 dB for upgrade port
Insertion loss typical value 0.8 dB for add port, 0.5 dB for upgrade port
Insertion loss penalty at all 0.5 dB
interfaces for temperature

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
range -25°C to +70°C
Passband width 13 nm according to ITU-T G.694
Isolation > 30 dB for drop port,
> 12 dB for upgrade port
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 30 ns

632 Module and System Specification


Chapter 9 Optical Filter Modules

OSFM+#1510
The OSFM+#1510 is an optical supervisory channel filter module with upgrade
port. It is used to add/drop an optical supervisory channel (OSC #1510)
into/from the network fiber while passing through the DWDM channel spectrum.
The OSFM+#1510 is only required in configurations where an OSCM-PN
equipped with an SFP/FE/C1510V/SM/LC is to be used.
Table 1102 provides general information about the module and its environment.

Table 1102: General Information


Equipment type OSFM
First release 8.2
Width 4 HP
Height 5 HU
Weight 490 g (1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption 1.2 W
Maximum RAM consumption on 24 Kbytes
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

NCU
MTBF at 25°C ambient temperature 30,618,494 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical interfaces.

Table 1103: Interfaces


Number of client ports (duplex) 1
Number of upgrade ports (duplex) 1
Number of network ports (duplex) 1
Optical connector type LC
Fiber type SM G.652

This table shows information about the optical characteristics of the multiplexer.

Table 1104: Optical Characteristics - Multiplexer


Insertion loss max. value 1.5 dB for 1510 nm add port
1.3 dB for upgrade port
Insertion loss typical value 0.7 dB for 1510 nm add port
0.5 dB for upgrade port
Directivity > 50 dB
Optical return loss > 40 dB

Module and System Specification 633


OSFM+#1510

Table 1104: Optical Characteristics - Multiplexer (Continued)


Passband width for OSC 1504.5 nm to 1517.5 nm
Passband width for upgrade port 1463.5 nm - 1497.5 nm
1523.5 nm - 1617.5 nm
Latency < 30 ns

This table shows information about the optical characteristics of the


demultiplexer.

Table 1105: Optical Characteristics - Demultiplexer


Insertion loss max. value 1.5 dB for 1510 nm drop port
1.5 dB for upgrade port
Insertion loss typical value 0.8 dB for 1510 nm drop port
0.6 dB for upgrade port
Isolation > 30 dB for drop port
Directivity > 50 dB
Optical return loss > 40 dB
Passband width for OSC 1504.5 nm to 1517.5 nm
Passband width for upgrade port 1463.5 nm - 1497.5 nm
1523.5 nm - 1617.5 nm
Latency < 30 ns

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

634 Module and System Specification


Chapter 9 Optical Filter Modules

2-OTFM+#1650
The 2-OTFM+#1650 is an optical time-domain reflectometer filter module with
upgrade port. It is used to add/drop of one or two OTDR signals at a wavelength
of #1650 nm on one or two network fibers for network monitoring. CWDM or
DWDM channel spectrum is forwarded between the network and network
element.
Table 1106 provides general information about the module and its environment.

Table 1106: General Information


Equipment type 2-OTFM
First release 9.3
Width 4 HP
Height 5 HU
Weight 650 g (1.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption 1.2 W
Maximum RAM consumption on 34 Kbytes
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

NCU
MTBF at 25°C ambient temperature 31,918,289 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the interfaces.

Table 1107: Interfaces


Number of client ports (Tx/Rx pair, 1
duplex)
Number of upgrade ports  1
(Tx/Rx pair)
Number of network ports  1
(Tx/Rx pair)
Optical connector type LC
Fiber type SM G.652

Module and System Specification 635


2-OTFM+#1650

This table shows information about the optical characteristics of the


demultiplexer.

Table 1108: Optical Characteristics


Insertion loss max. value 1.5 dB for 1650 nm add port
2 dB for upgrade port
Insertion loss typical value 1.1 dB for 1650 nm add port
0.8 dB for upgrade port
Isolation > 30 dB for drop port
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 1643.5 nm to 1657.5 nm
Latency < 20 ns

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

636 Module and System Specification


Chapter 9 Optical Filter Modules

5PSM
The 5PSM (5 Port Splitter Combiner Module) is a power splitter module
specifically designed for the deployment of an CCM-C40/8 or CCM-C80/8.
Table 1109 provides general information about the module and its environment.

Table 1109: General Information


Equipment type 5PSM
First release 9.2
Width 4 HP
Height 5 HU
Weight 499 g (1.1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 10,416,667 h
Power consumption 1.2 W
Maximum RAM consumption on NCU 19 Kbytes
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

SH1HU: 1, 2

The following table contains information about the optical interfaces.

Table 1110: Optical Interfaces


Number of client ports 5
Number of network ports 1
Optical connector type LC
Fiber type SM G.652

The following table contains information about the optical characteristics.

Table 1111: Optical Characteristics


Operating wavelengths 1528 nm...1562 nm
Latency < 33 ns
N-D max input power 21 dBm
N-D to C-D max. insertion loss 9.3 dB (EOL)
N-D to C-D typ. insertion loss 7.3 dB (EOL)
C-M max input power 20 dBm
C-M to N-M max. insertion loss 9.3 dB (EOL)
C-M to N-M typ. insertion loss 7.3 dB (EOL)
N-M max induced non-uniformity 1 dB
between channels
Return loss (all ports) > 40 dB

Module and System Specification 637


8PSM

8PSM
The 8PSM (8 Port Splitter Module) is designed to divide the optical channels
received by the network port into identical copies for output on all client ports.
The module combines optical channels received on the client ports for output on
the network port.
Table 1112 provides general information about the module and its environment.

Table 1112: General Information


Equipment type 8PSM
First release 12.3
Width 8 HP
Height 5 HU
Weight 1000 g (2.2 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 1,664,957 h
Power consumption 1.2 W
Maximum RAM consumption on NCU 34 Kbytes

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Slot positions SH9HU: 3...17
SH1HU: 1

The following table contains information about the optical interfaces.

Table 1113: Optical Interfaces


Number of client ports 8
Number of network ports 1
Optical connector type LC
Fiber type SM G.652

The following table contains information about the optical characteristics.

Table 1114: Optical Characteristics


Operating wavelengths 1528 nm...1570 nm
Latency 15 ns
N-R max input power 24 dBm
N-R to C-T max. insertion loss 10.6 dB (EOL)
N-R to C-T min. insertion loss 9.0 dB (EOL)
C-R max total input power for all ports 24 dBm
C-R to N-T max. insertion loss 10.6 dB (EOL)
C-R to N-T min. insertion loss 9.0 dB (EOL)

638 Module and System Specification


Chapter 9 Optical Filter Modules

Table 1114: Optical Characteristics (Continued)


N-T max induced non-uniformity 1 dB
between channels
Return loss (all ports) > 40 dB
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 639


PSM-95/5

PSM-95/5
The PSM-95/5 is a power splitter module specifically designed for power
monitoring and optical spectrum analysis. It contains a splitter that splits the
optical power of the input signal into two portions.
Table 1115 provides general information about the module and its environment.

Table 1115: General Information


Equipment type PSM
First release 7.1
Width 4HP
Height 5 HU
Weight 480 g (1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 122,956 h
Power consumption 1.2 W
Maximum RAM consumption on NCU 26 Kbytes
Slot positions SH9HU: 3...18

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical interfaces.

Table 1116: Optical Interfaces


Number of client port 1
Number of network port 1
Number of monitoring port1 1
Optical connector type LC
Fiber type SM G.652
1. Should be used to measure approx. 5% of the wavelength spectrum.
It is not intended for power measurements.

The following table contains information about the optical characteristics.

Table 1117: Optical Characteristics


Operating wavelengths 1470 nm...1610 nm
Insertion loss client-network port max. value 1.1 dB
Insertion loss client-network port typical value 0.5 dB
Insertion loss client-monitoring port max. value < 16 dB
Insertion loss client-monitoring port typical value 13.6 dB
Optical return loss (all ports) > 40 dB
Latency < 30 ns

640 Module and System Specification


Chapter 9 Optical Filter Modules

2PSM-95/5
The 2PSM-95/5 is a dual power splitter module specifically designed for power
monitoring and optical spectrum analysis. The module contains two
bi-directional power splitters that monitor the optical power of a received and
transmitted signal. The signal paths are split with 5% of the signal directed to a
monitor port.
Table 1118 provides general information about the module and its environment.

Table 1118: General Information


Equipment type 2PSM
First release 11.1
Width 4HP
Height 5 HU
Max. weight 493 g (1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 2,138,351 h
Power consumption 1.2 W
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Maximum RAM consumption on 29 Kbytes


NCU
Slot positions SH9HU: 3...18
SH7HU: 3...18
SH1HU: 1 or 2

The following table contains information about the optical interfaces.

Table 1119: Optical Interfaces


Number of client ports (duplex) 1 (for ingress and egress in the client
direction)
Number of network ports (duplex) 1 (for ingress and egress in the
network direction)
Number of monitoring ports (duplex) 1 (for ingress and egress of the
network receive and client transmit
power levels)
Optical connector type LC
Fiber type SM G.652

The following table contains information about the optical characteristics.

Table 1120: Optical Characteristics


Operating wavelengths 1470 nm...1610 nm
Max. insertion loss client-network (C/R to N/T) and 1.1 dB
network-client (N/R to C/T)

Module and System Specification 641


2PSM-95/5

Table 1120: Optical Characteristics (Continued)


Typ. insertion loss client-network (C/R to N/T) and 0.7 dB
network-client (N/R to C/T)
Max. insertion loss client-monitoring (C/R to Mon) < 16 dB
and network-monitoring (N/R to Mon)
Typ. insertion loss client-monitoring (C/R to Mon) 13.6 dB
and network-monitoring (N/R to Mon)
Optical return loss (all ports) > 40 dB
Latency < 30 ns

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

642 Module and System Specification


Chapter 9 Optical Filter Modules

1PM/SM
The 1PM/SM (single-port protection module single-mode) is an optical module
that provides channel card protection. It has one client port and accepts
single-mode signals.
The 1PM/SM splits one optical signal received on the client port into two
duplicate signals for output on the network ports west and east. In the other
direction, the module combines the optical signals received on each network
port into an multiplex for output on the client port.
Table 1121 provides general information about the module and its environment.

Table 1121: General Information


Equipment type 1PM
First release 7.0
Width 4 HP
Height 5 HU
Weight 480 g (1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 20,833,333 h
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Power consumption 1.2 W


Maximum RAM consumption on 31 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical interfaces.

Table 1122: Optical Interfaces


Number of client ports (duplex) 1
Number of network ports (duplex) 2
Optical connector type LC
Fiber type SM G.652

The following table provides information about the optical characteristics.

Table 1123: Optical Characteristics


Operating wavelengths 1260 nm ... 1360 nm
1529 nm ... 1604 nm
Insertion loss max. value 3 dB ... 4 dB
Insertion loss typ. value 3.3 dB
Optical return loss > 40 dB
Directivity > 50 dB
Latency < 30 ns

Module and System Specification 643


1PM/MM

1PM/MM
The 1PM/MM (single-port protection module multimode) is an optical module
that provides channel card protection. It has one client port and accepts
single-mode and multimode signals.
The 1PM/MM splits one optical signal received on the client port into two
duplicate signals for output on the network ports west and east. In the other
direction, the module combines the optical signals received on each network
port into an multiplex for output on the client port.
Table 1124 provides general information about the module and its environment.

Table 1124: General Information


Equipment type 1PM
First release 7.0
Width 4 HP
Height 5 HU
Weight 480 g (1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 20,833,333 h
Power consumption 1.2 W
Maximum RAM consumption on 31 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical interfaces.

Table 1125: Optical Interfaces


Number of client ports (duplex) 1
Number of network ports (duplex) 2
Optical connector type LC
Fiber type 62.5 µm MM G.651

The following table provides information about the optical characteristics.

Table 1126: Optical Characteristics


Operating wavelengths 830 nm ... 860 nm
1290 nm ... 1360 nm
Insertion loss > 3.0 dB (fulfilled launch condition)
Directivity > 40 dB
Latency < 30 ns

644 Module and System Specification


Chapter 9 Optical Filter Modules

2PM/SM
The 2PM/SM (2-port protection module single-mode) is an optical module that
provides channel card protection. It has two client ports and accepts
single-mode signals only. The 2PM/SM splits two optical signals received on the
client ports into four duplicate signals for output on the network ports west and
east. In the other direction, the module combines the optical signals received on
each network ports into an multiplex for output on the client ports.
Table 1127 provides general information about the module and its environment.

Table 1127: General Information


Equipment type 2PM
First release 7.0
Width 4 HP
Height 5 HU
Weight 520 g (1.1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 10,416,667 h
Power consumption 1.2 W
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Maximum RAM consumption on 27 Kbytes


NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical connector and fiber
type.

Table 1128: Optical Interfaces


Number of client ports (duplex) 2
Number of network ports (duplex) 4
Optical connector type LC
Fiber type SM G.652

The following table provides information about the optical characteristics.

Table 1129: Optical Characteristics


Operating wavelengths 1260 nm ... 1360 nm
1529 nm ... 1604 nm
Insertion loss max. value 3 dB ... 4 dB
Insertion loss typ. value 3.3 dB
Optical return loss > 40 dB
Directivity > 50 dB
Latency < 30 ns

Module and System Specification 645


2PM/MM

2PM/MM
The 2PM/MM (2-port protection module multimode) is an optical module that
provides channel card protection. It has two client ports and accepts multimode
signals only.
The 2PM/MM splits two optical signals received on the client ports into four
duplicate signals for output on the network ports west and east. In the other
direction, the module combines the optical signals received on each network
ports into an multiplex for output on the client ports.
Table 1130 provides general information about the module and its environment.

Table 1130: General Information


Equipment type 2PM
First release 7.0
Width 4 HP
Height 5 HU
Weight 520 g (1.1 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 10,416,666 h
Power consumption 1.2 W
Maximum RAM consumption on 27 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2

The following table contains information about the optical interfaces.

Table 1131: Optical Interfaces


Number of client ports (duplex) 2
Number of network ports (duplex) 4
Optical connector type LC
Fiber type 62.5 µm MM G.651

The following table provides information about the optical characteristics.

Table 1132: Optical Characteristics


Operating wavelengths 830 nm ... 860 nm
1290 nm ... 1360 nm
Insertion loss > 3.0 dB (fulfilled launch condition)
Directivity > 40 dB
Latency < 30 ns

646 Module and System Specification


Chapter 9 Optical Filter Modules

Y-Cable/SM
The y-cable/SM (single-mode y-cable) is a 3-port fiber-optic cable with an
integrated 50/50 coupler facilitate channel card protection. It has one client port,
two network ports and accepts single-mode signals only.
The single mode y-cable splits one optical signal received on the client port
(single end) into two duplicate signals for output on the network ports 1 and 2. In
the other direction, the cable combines the optical signals received on each
client port into an multiplex for output on the client port.
The single-mode y-cable can be used either the Transmit (Tx) or Receive (Rx)
direction at either end of a fiber span.
The single-mode y-cable is available in six variants:

Y-Cable/SM Variants Description


J-Y/SM/LC/0310 Y-cable for Channel card protection, 3.10 m long,
single-mode fiber, LC connectors on client and
network ports
J-Y/SM/LC/1000 Y-cable for Channel card protection, 10.00 m long,
single-mode fiber, LC connectors on client and
network ports
J-Y/SM/LC-SC/0310 Y-cable for Channel card protection, 3.10 m long,
single-mode fiber, LC to SC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

J-Y/SM/LC-SC/1000 Y-cable for Channel card protection, 10.00 m long,


single-mode fiber, LC to SC
J-Y/SM/LC-FC/0310 Y-cable for Channel card protection, 3.10 m long,
single-mode fiber, LC to FC
J-Y/SM/LC-FC/1000 Y-cable for Channel card protection, 10.00 m long,
single-mode fiber, LC to FC

These single-mode y-cables provide the same function as a 1PM/SM or


2PM/SM module. Two single-mode y-cables are required to replace one
1PM/SM, and four single-mode y-cables are needed to replace one 2PM/SM.
Table 1133 provides general specifications for the single-mode y-cable.

Table 1133: General Specifications


Equipment type (depends on Y_SM_LC, Y_SM_SC-LC,
variant) Y_SM_FC-LC
First release 12.2
Lengths (depends on variant) 3.10 m (10.17 ft.) or 10.00 m (32.81 ft.)
Weight 3.10-meter cable: 45 g (1.6 oz.)
10.00-meter cable: 100 g (3.5 oz.)
MTBF at 25°C ambient temperature 177,619,893 h

Module and System Specification 647


Y-Cable/SM

Table 1133 contains information about the optical interfaces.

Table 1134: Optical Interfaces


Number of client ports (simplex) 1
Number of network ports (simplex) 2
Optical connector type LC, FC or SC on client port (depends
on variant)
LC on network port
Fiber type SM G.652

Table 1135 provides information about the optical characteristics.

Table 1135: Optical Characteristics


Operating wavelengths 1260 nm ... 1360 nm
1529 nm ... 1604 nm
Maximum insertion loss 4.5 dB
Insertion loss typ. value 4.1 dB
Optical return loss > 40 dB
Directivity > 50 dB
Latency < 53 ns for 10.00-meters cable
< 17 ns for 3.10-meters cable

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

648 Module and System Specification


Chapter 9 Optical Filter Modules

Y-Cable/MM
The y-cable/MM (62.5 µm multimode y-cable) is a 3-port fiber-optic cable with
an integrated 50/50 coupler to facilitate channel card protection. It has one client
port, two network ports and accepts multimode signals only.
The 62.5 µm multimode y-cable splits one optical signal received on the client
port (single end) into two duplicate signals for output on the network ports 1 and
2. In the other direction, the cable combines the optical signals received on each
client port into an multiplex for output on the client port.
The multimode y-cable can be used either the Transmit (Tx) or Receive (Rx)
direction at either end of a fiber span.
The 62.5 µm multimode y-cable is available in four variants:

Y-Cable/MM Variants Description


J-Y/MM62/LC/0310 Y-cable for Channel card protection, 3.10 m long,
62.5 µm multimode fiber, LC connectors on client and
network ports
J-Y/MM62/LC/1000 Y-cable for Channel card protection, 10.00 m long,
62.5 µm multimode fiber, LC connectors on client and
network ports
J-Y/MM62/LC-SC/0310 Y-cable for Channel card protection, 3.10 m long,
62.5 µm multimode fiber, LC to SC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

J-Y/MM62/LC-SC/1000 Y-cable for Channel card protection, 10.00 m long,


62.5 µm multimode fiber, LC to SC

These 62.5 µm multimode y-cables provide the same function as a 1PM/MM or


2PM/MM module. Two multimode y-cables are required to replace one
1PM/MM, and four multimode y-cables are needed to replace one 2PM/MM.
Table 1133 provides general specifications for the multimode y-cable.

Table 1136: General Specifications


Equipment type (depends on variant) Y_MM_LC, Y_MM_SC-LC
First release 12.2
Lengths (depends on variant) 3.10 m (10.17 ft.) or 10.00 m (32.81 ft.)
Weight 3.10-meter cable: 45 g (1.6 oz.)
10.00-meter cable: 100 g (3.5 oz.)
MTBF at 25°C ambient temperature 177,619,893 h

Module and System Specification 649


Y-Cable/MM

Table 1133 contains information about the optical interfaces.

Table 1137: Optical Interfaces


Number of client ports (simplex) 1
Number of network ports (simplex) 2
Optical connector types LC, FC or SC on client port (depends
on variant)
LC on network port
Fiber type 62.5 µm MM G.651

Table 1135 provides information about the optical characteristics.

Table 1138: Optical Characteristics


Operating wavelengths 830 nm ... 860 nm
1260 nm ... 1360 nm
Insertion loss > 3.0 dB (fulfilled launch condition)
Directivity > 50 dB
Latency < 53 ns for 10.00-meters cable
< 17 ns for 3.10-meters cable

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

650 Module and System Specification


Chapter 9 Optical Filter Modules

J/SM/4CS-#C1270-#C1330/LC/0400
The J/SM/4CS-#C1270-#C1330/LC/0400 is a 5-port unidirectional CWDM
channel splitter/combiner for channels #C1270 - #C1330. It is designed for
connecting a 40G transceiver CFP (LR4) to four 10G transceiver SFP+
interfaces, enabling transmission of 40G traffic over 10G channels.
Each port of the J/SM/4CS-#C1270-#C1330/LC/0400 is terminated with a single
mode LC connector. The ports associated with the four separate wavelengths
are the network ports, while the port associated with the aggregate 40G signal is
the client port. The corresponding wavelength is printed on each network port.

As the J/SM/4CS-#C1270-#C1330/LC/0400 is a passive unit, it is not


PS

visible in the inventory database. Therefore, it is not supported by


inventory management, the Control Plane, or the Network Manager.
Note

Table 1139 provides general specifications for the


J/SM/4CS-#C1270-#C1330/LC/0400 cable.

Table 1139: General Specifications


Equipment type J/SM/4CS-#C1270-#C1330/LC/0400
First release 12.3
Pigtail length client port: 3 m
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

(Pigtails coupled with LC connectors) network port: 1m


Filter Dimensions max. 35 mm x 12 mm x 10 mm
Weight 100 g (3.5 oz)
MTBF at 25°C ambient temperature 10,869,565 h

Table 1140 contains information about the optical interfaces.

Table 1140: Optical Interfaces


Number of client ports (simplex) 1
Number of network ports (simplex) 4
Optical connector types LC
Fiber type SM G.652

Table 1141 provides information about the optical characteristics of the


demultiplexer.

Table 1141: Optical Characteristics - Demultiplexer


Insertion loss client to network ports 2.0 dB
max. value
Insertion loss client to network ports 1.3 dB
typ. value
Passband width 13 nm according to ITU-T G.694
Isolation for adjacent channels > 30 dB
Directivity > 50 dB

Module and System Specification 651


J/SM/4CS-#C1270-#C1330/LC/0400

Table 1141: Optical Characteristics - Demultiplexer


Optical return loss > 40 dB
Latency < 20 ns

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

652 Module and System Specification


Chapter 10

Optical Amplifiers
This chapter describes the optical amplifiers of the FSP 3000R7.
The descriptions of the discontinued optical amplifiers can be found in a former
version of the FSP 3000R7 Module and System Specification.
The following sections are provided:
“EDFA-C-D17-GC” on p. 654
“EDFA-L-D17-GC” on p. 657
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

“EDFA-C-S20-GCB-DM” on p. 660
“EDFA-C-D20-VGC-DM” on p. 663
“EDFA-C-D20-VLGC-DM” on p. 667
“EDFA-C-S26-VGC-DM” on p. 671
“EDFA-C-S26-VGCB-DM” on p. 675
“RAMAN-C10” on p. 679
“2RAMAN-C15-LL” on p. 684
“AMP-S20H-C15” on p. 692
“AMP-S20L-C15” on p. 699
“EDFA-S20H” on p. 706
“EDFA-S20L” on p. 711
“2EDFA-S20L-S10L” on p. 716

Module and System Specification 653


EDFA-C-D17-GC

EDFA-C-D17-GC
The EDFA-C-D17-GC is a gain-controlled, double-stage Erbium-doped fiber
amplifier supporting amplification of up to 80 channels in the C band. The first
gain block works as preamplifier, the second as booster amplifier. The midstage
access allows to connect a dispersion compensation module without effecting
the line budget. The gain and transient controller regulates the pump laser to
stabilize the ratio between output and input power, i.e. the gain of the
amplification stage. The EDFA-C-D17-GC can be used as preamplifier, booster
or inline amplifier.
Table 1142 provides general information about the module and its environment.

Table 1142: General Information


Equipment type EDFA-DGC
First release 7.0
Width 4 HP
Height 5 HU
Weight 705 g (1.6 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 512,558 h
Typ. power consumption 16 W
Max. power consumption 26 W
Maximum RAM consumption on 56 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P

The following table contains information about the ports.

Table 1143: Ports


Optical connector type LC
Fiber type G.652
1/R signal input (amplifier port)
1/T signal output (amplifier port)
2/R input from dispersion compensation module
(midstage port)
2/T output to dispersion compensation module
(midstage port)
Mon/T approx. 1% of EDFA OUT

654 Module and System Specification


Chapter 10 Optical Amplifiers

This table provides information about the optical specification.

Table 1144: Optical Specification


Number of amplifiers 2 gain blocks
Min. wavelength 1529.40 nm
Max. wavelength 1563.05 nm
Min. total optical input power -32 dBm
Max. total optical input power -8 dBm
Min. per channel input power -32 dBm
Max. per channel input power -14 dBm for 4 channels
-17 dBm for 8 channels
-20 dBm for 16 channels
-23 dBm for 32 channels
-24 dBm for 40 channels
-27 dBm for 80 channels
Average gain 26 dB
Midstage loss 0 ... 9.7 dB
Tilt set range -2 ... 0 dB
Default tilt setting 0 dB
Min. per channel gain 25 dB
Max. total optical output power < 18 dBm
Nominal total optical output power 17.2 dBm
at -8 dBm total optical input power
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Gain flatness (over all conditions) 1.6 dBpp


Noise figure 6 dB
Optical return loss -40 dB
Polarization dependent gain 0.5 dB

The following table contains information about the system performance.

Table 1145: System Performance


Latency 700 ns
Max. allowable per channel power 6 dBm for G.652
into the transmission fiber 5 dBm for G.653, G.655

This table provides information about fault monitoring of the module in general.

Table 1146: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA

Module and System Specification 655


EDFA-C-D17-GC

This table shows information about fault monitoring of the amplifier ports.

Table 1147: Fault Monitoring Amplifier Ports


Physical layer Laser failure;
Laser degrade (based on bias current);
Midstage fault;
Loss of signal (LOS);
Optical power Rx too high/too low (OPR);
Optical power Tx too high/too low (OPT);
Laser temperature too high/low

This table shows information about fault monitoring of the midstage ports.

Table 1148: Fault Monitoring Midstage Ports


Physical layer Laser failure;
Laser degrade (based on bias current);
Loss of signal (LOS);
Laser temperature too high/low

The following table provides information about performance monitoring of the


module in general.

Table 1149: Performance Monitoring - General


Equipment Module temperature (current value)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Gain block temperature (current value)

This table shows information about performance monitoring of amplifier ports.

Table 1150: Performance Monitoring Amplifier Ports


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high);
values except current values; User con- Optical power Tx (current, low,
figurable threshold crossing alerts for mean, high);
OPR too high/too low available; Fix Laser bias current (current value);
threshold crossing alerts for OPT too Laser temperature (current value);
high/too low available) Defect seconds (DS)

This table shows information about performance monitoring of midstage ports.

Table 1151: Performance Monitoring Midstage Ports


Physical layer Optical power Rx (current value);
Optical power Tx (current value);
Attenuation between stages (current value);
Attenuation of VOA (current value)

Pay attention that the specified maximum per channel input


power is valid only if no DCM connected to the midstage ports is
PS

used. For details, refer to Appendix B: Use of DCM with


Note Doublestage EDFA.

656 Module and System Specification


Chapter 10 Optical Amplifiers

EDFA-L-D17-GC
The EDFA-L-D17-GC is a gain-controlled, double-stage Erbium-doped fiber
amplifier supporting amplification of up to 40 channels in the L band. The first
gain block works as preamplifier, the second as booster amplifier. The midstage
access allows to connect a dispersion compensation module without effecting
the line budget. The gain and transient controller regulates the pump laser to
stabilize the ratio between output and input power, i.e. the gain of the
amplification stage. The EDFA-L-D17-GC can be used as preamplifier, booster
or inline amplifier.
Table 1152 provides general information about the module and its environment.

Table 1152: General Information


Equipment type EDFA-DGC
First release 7.0
Width 8 HP
Height 5 HU
Weight 1.25 kg (2.8 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

MTBF at 25°C ambient temperature 469,925 h


Typ. power consumption 20 W
Max. power consumption 26 W
Maximum RAM consumption on 56 Kbytes
NCU
Slot positions SH9HU: 3...17
SH7HU, SH7HU-R: 3...17
SH1HU: 1
NCU types NCU, NCU-II, NCU-II-P

The following table contains information about the ports.

Table 1153: Ports


Optical connector type LC
Fiber type G.652
1/R signal input (amplifier port)
1/T signal output (amplifier port)
2/R input from dispersion compensation
module (midstage port)
2/T output to dispersion compensation
module (midstage port)
Mon T approx. 1% of EDFA OUT

Module and System Specification 657


EDFA-L-D17-GC

This table provides information about the optical specification.

Table 1154: Optical Specification


Number of amplifiers 2 gain blocks
Min. wavelength 1569.59 nm
Max. wavelength 1603.17 nm
Min. total optical input power -32 dBm
Max. total optical input power -8 dBm
Min. per channel input power -32 dBm
Max. per channel input power -14 dBm for 4 channels
-17 dBm for 8 channels
-20 dBm for 16 channels
-23 dBm for 32 channels
-24 dBm for 40 channels
Average gain 26 dB
Midstage loss 0 ... 9.7 dB
Tilt set range -2 ... 0 dB
Default tilt setting 0 dB
Min. gain per channel 24.5 dB
Max. total optical output power < 18 dBm
Nominal total optical output power 17.2 dBm
at -8 dBm total optical input power
Gain flatness (over all conditions) 1.6 dBpp

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Gain flatness (1569.59 to 1570.42 2 dBpp
nm)
Noise figure 6.8 dB
Optical return loss -40 dB
Polarization dependent gain 0.5 dB

The following table contains information about the system performance.

Table 1155: System Performance


Latency 700 ns
Max. allowable per channel power 6 dBm for G.652
into the transmission fiber 5 dBm for G.653, G.655

This table provides information about fault monitoring of the module in general.

Table 1156: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA

658 Module and System Specification


Chapter 10 Optical Amplifiers

This table shows information about fault monitoring of the amplifier ports.

Table 1157: Fault Monitoring Amplifier Ports


Physical layer Laser failure;
Laser degrade (based on bias current);
Midstage fault;
Loss of signal (LOS);
Optical power Rx too high/too low (OPR);
Optical power Tx too high/too low (OPT);
Laser temperature too high/low

This table shows information about fault monitoring of the midstage ports.

Table 1158: Fault Monitoring Midstage Ports


Physical layer Laser failure;
Laser degrade (based on bias current);
Loss of signal (LOS);
Laser temperature too high/low

Table below provides information about performance monitoring of the module.

Table 1159: Performance Monitoring - General


Equipment Module temperature (current value);
Gain block temperature (current value)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

This table shows information about performance monitoring of the amplifier


ports.

Table 1160: Performance Monitoring Amplifier Ports


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high);
values except current values; Optical power Tx (current, low,
User configurable threshold crossing mean, high);
alerts for OPR too high/too low avail- Laser bias current (current value);
able; Fix threshold crossing alerts for Laser temperature (current value);
OPT too high/too low available) Defect seconds (DS)

This table shows information about performance monitoring of the midstage


ports.

Table 1161: Performance Monitoring Midstage Ports


Physical layer Optical power Rx (current value);
Optical power Tx (current value);
Attenuation between stages (current value);
Attenuation of VOA (current value)

Pay attention that the specified maximum per channel input


power is valid only if no DCM connected to the midstage ports is
PS

used. For details, refer to Appendix B: Use of DCM with


Note Doublestage EDFA.

Module and System Specification 659


EDFA-C-S20-GCB-DM

EDFA-C-S20-GCB-DM
The EDFA-C-S20-GCB-DM is a fixed gain-controlled, single-stage, dual
monitoring Erbium-doped fiber booster amplifier to amplify up to 80 channels in
the C band. The gain and transient controller regulates the pump laser to
stabilize the ratio between output and input power, i.e. the gain of the
amplification stage. The power level of the incoming weak signal and outgoing
amplified signal may be monitored.
Table 1162 provides general information about the module and its environment.

Table 1162: General Information


Equipment type EDFA-SGCB
First release 8.2
Width 4 HP
Height 5 HU
Weight 525 g (1.16 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 636,067 h

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Typ. power consumption 11 W
Max. power consumption 22 W
Maximum RAM consumption on 44 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P

The following table contains information about the ports.

Table 1163: Ports


Optical connector type LC
Fiber type G.652
1/R signal input
1/T signal output
Mon T approx. 1% of EDFA OUT
Mon R approx. 1% of EDFA IN

This table provides information about the optical specification.

Table 1164: Optical Specification


Number of amplifiers 1 gain block
Min. wavelength 1529.40 nm

660 Module and System Specification


Chapter 10 Optical Amplifiers

Table 1164: Optical Specification (Continued)


Max. wavelength 1563.05 nm
Min. total optical input power -32 dBm
Max. total optical input power 0 dBm
Min. per channel input power -32 dBm
Max. per channel input power -6 dBm for 4 channels
-9 dBm for 8 channels
-12 dBm for 16 channels
-15 dBm for 32 channels
-16 dBm for 40 channels
-19 dBm for 80 channels
Average gain 20 dB
Max. total optical output power 20.5 dBm
Gain flatness (over all conditions) 1.2 dBpp
Noise figure 5.5 dB
Transient Response Transients up to 15 dB per 100 µs are
compressed to < 1.5dB with setting
time of <1ms.
Optical input return loss > 40 dB
Polarization dependent gain 0.5 dB
OPR/OPT accuracy +/- 1 dB

The following table contains information about the system performance.


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 1165: System Performance


Latency < 150 ns up to HW 2.01
< 135 ns from HW 3.01
Max. allowable per channel power 6 dBm for G.652
into the transmission fiber 5 dBm for G.653, G.655

This table provides information about fault monitoring of the module.

Table 1166: Fault Monitoring


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA
Physical layer Laser failure;
Laser degrade (based on bias current);
Loss of signal (LOS);
Optical power Rx too high/too low (OPR);
Optical power Tx too high/too low (OPT);
Gain block temperature

Module and System Specification 661


EDFA-C-S20-GCB-DM

The following table provides information about performance monitoring of the


module.

Table 1167: Performance Monitoring


Equipment Module temperature (current value)
Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high, OPR sampling rate 50
values except current values; ms to capture short events for low,
User configurable threshold crossing mean, and high)
alerts for OPR too high/too low avail- Optical power Tx (current, low,
able; mean, high, OPT sampling rate 50
Fix threshold crossing alerts for OPT too ms to capture short events for low,
high/too low available) mean, and high)
Laser bias current (current value);
Defect seconds (DS)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

662 Module and System Specification


Chapter 10 Optical Amplifiers

EDFA-C-D20-VGC-DM
The EDFA-C-D20-VGC-DM is a gain-controlled, double-stage, dual monitoring
Erbium-doped fiber amplifier with a variable gain supporting amplification of up
to 80 channels in the C band.
The first gain block works as preamplifier, the second as booster amplifier. The
midstage access allows to insert a dispersion compensation module without
effecting the line budget. A variable optical attenuator (VOA) at the midstage
access controls and suitably adjusts attenuation of up to 16 dB depending on
whether a dispersion compensating module or a jumper connects the two gain
blocks. The gain and transient controller regulates the pump laser to stabilize
the ratio between output and input power, i.e. the gain of the amplification stage.
The power level of the incoming weak signal and outgoing amplified signal may
be monitored.
The EDFA-C-D20-VGC-DM can be used as preamplifier, booster or inline
amplifier.
Table 1168 provides general information about the module and its environment.

Table 1168: General Information


Equipment type EDFA-DGCV
First release 8.2
Width 4 HP
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Height 5 HU
Weight 565 g (1.2 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 630,926 h
Typ. power consumption 15 W
Max. power consumption 26 W
Maximum RAM consumption on 61 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P

The following table contains information about the ports.

Table 1169: Ports


Optical connector type LC
Fiber type G.652
1/R signal input (amplifier port)
1/T signal output (amplifier port)
2/R input from dispersion compensation module
(midstage port)

Module and System Specification 663


EDFA-C-D20-VGC-DM

Table 1169: Ports (Continued)


2/T output to dispersion compensation module
midstage port)
Mon T approx. 1% of EDFA OUT
Mon R approx. 1% of EDFA IN

This table provides information about the optical specification.

Table 1170: Optical Specification


Number of amplifiers 2 gain blocks
Min. wavelength 1529 nm
Max. wavelength 1562 nm
Min. total optical input power at gain 26 dB: -35 dBm
Max. total optical input power -15 dBm at Gain = 35 dB
-12 dBm at Gain = 32 dB
-9 dBm at Gain = 29 dB
-6 dBm at Gain = 26 dB
-3 dBm at Gain = 23 dB
+1 dBm at Gain = 19 dB
Gain set range 19 ... 35 dB
Midstage loss 0 dB at Gain = 35 dB
0 dB ... 3 dB at Gain = 32 dB
0 dB ... 6 dB at Gain = 29 dB
0 dB ... 9 dB at Gain = 26 dB

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
0 dB ... 12 dB at Gain = 23 dB
0 dB ... 16 dB at Gain = 19 dB
Tilt set -1dB tilt (default) allowed for entire gain set
range
0 dB tilt allowed for gain <33.4 dB (0 dB tilt
set is possible only when DCM loss has 
1.5 dB of margin for a given gain setting)
-0.5 dB tilt allowed for gain <34.2 dB
-1.5 dB tilt allowed for gain >19.8 dB
-2.0 dB tilt allowed for gain >20.6 dB
Default tilt setting -1 dB
Tilt accuracy +/- 0.3 dB for gain set range 19 dB ... 32 dB
+/- 0.5 dB for gain set range > 32 dB
Max. total optical output power < 21.3 dBm
Gain flatness (over all 1.5 dBpp for gain set range 19 dB ... 32 dB
conditions) 2 dBpp for gain set range > 32 dB
Noise figure 5.2 dB at Gain > 30 dB
5.5 dB at Gain = 26 dB
7 dB at Gain = 23 dB
10 dB at Gain = 19 dB
Transient Response Transients up to 15 dB per 100 µs are
compressed to <2.0dB with setting time of
<1ms.
Optical input return loss -40 dB

664 Module and System Specification


Chapter 10 Optical Amplifiers

Table 1170: Optical Specification (Continued)


Polarization dependent gain 0.5 dB
OPR/OPT accuracy +/- 1 dB

The following table contains information about the system performance.

Table 1171: System Performance


Latency < 250 ns
Max. allowable per channel power into 6 dBm for G.652
the transmission fiber 5 dBm for G.653, G.655

This table provides information about fault monitoring of the module in general.

Table 1172: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA

This table shows information about fault monitoring of the amplifier ports.

Table 1173: Fault Monitoring Amplifier Ports


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Physical layer Laser failure;


Laser degrade (based on bias current);
Midstage fault;
Loss of signal (LOS);
Optical power Rx too high/too low (OPR);
Optical power Tx too high/too low (OPT);
Laser temperature too high/low

This table shows information about fault monitoring of the midstage ports.

Table 1174: Fault Monitoring Midstage Ports


Physical layer Laser failure;
Laser degrade (based on bias current);
Loss of signal (LOS);
Laser temperature too high/low

The following table provides information about performance monitoring of the


module in general.

Table 1175: Performance Monitoring - General


Equipment Module temperature (current value)
Gain block temperature (current value)

Module and System Specification 665


EDFA-C-D20-VGC-DM

This table shows information about performance monitoring of the amplifier


ports.

Table 1176: Performance Monitoring Amplifier Ports


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM val- mean, high, OPR sampling rate
ues except current values; 50 ms to capture short events for
User configurable threshold crossing low, mean, and high)
alerts for OPR too high/too low available; Optical power Tx (current, low,
Fix threshold crossing alerts for OPT too mean, high, OPT sampling rate
high/too low available) 50 ms to capture short events for
low, mean, and high)
Laser bias current (current
value);
Laser temperature (current
value);
Defect seconds (DS)

This table shows information about performance monitoring of the midstage


ports.

Table 1177: Performance Monitoring Midstage Ports


Physical layer Optical power Rx (current value);
Optical power Tx (current value);

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Attenuation between stages (current value);
Attenuation of VOA (current value);
Laser bias current (current value);
Laser temperature (current value);

666 Module and System Specification


Chapter 10 Optical Amplifiers

EDFA-C-D20-VLGC-DM
The EDFA-C-D20-VLGC-DM is a gain-controlled, double-stage, dual monitoring
Erbium-doped fiber amplifier with a variable low gain supporting amplification of
up to 80 channels in the C band.
The first gain block works as preamplifier, the second as booster amplifier. The
midstage access allows to connect to a dispersion compensation module
without affecting the line power budget. A variable optical attenuator (VOA) prior
to the midstage access controls and adjusts the attenuation to change the gain
to the desired level between 12 and 27 dB subject to constraints imposed by the
midstage loss. The maximum gain of the dual stage amplifier with DCM in the
midstage is equal to 27 dB - DCM loss. The gain and transient controller
regulates the pump laser to stabilize the ratio between output and input power,
i.e. the amplifier operates in gain locked mode with fast transient suppression.
The power level of the incoming weak signal and outgoing amplified signal
could be monitored in service with internal photodiodes as well as externally
with monitoring equipment connected to the tap ports.
The EDFA-C-D20-VLGC-DM can be used as preamplifier, booster or inline
amplifier.
Table 1178 provides general information about the module and its environment.

Table 1178: General Information


Equipment type EDFA-DGCV
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

First release 9.2


Width 4 HP
Height 5 HU
Weight 564 g (1.2 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 478,254 h
Typ. power consumption 18 W
Max. power consumption 26 W
Maximum RAM consumption on 61 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P

The following table contains information about the ports.

Table 1179: Ports


Optical connector type LC
Fiber type G.652

Module and System Specification 667


EDFA-C-D20-VLGC-DM

Table 1179: Ports (Continued)


1/R signal input (amplifier port)
1/T signal output (amplifier port)
2/R input from dispersion compensation module
(midstage port)
2/T output to dispersion compensation module
(midstage port)
Mon T approx. 1% of EDFA OUT
Mon R approx. 1% of EDFA IN

This table provides information about the optical specification.

Table 1180: Optical Specification


Number of amplifiers 2 gain blocks
Min. wavelength 1529 nm
Max. wavelength 1563 nm
Min. total optical input power -32 dBm
Max. total optical input power -7 dBm at Gain = 27 dB
-4 dBm at Gain = 24 dB
-1 dBm at Gain = 21 dB
+2 dBm at Gain = 18 dB
+5 dBm at Gain = 15 dB
+8 dBm at Gain = 12 dB

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Gain set range 12 ... 27 dB
Midstage loss 0 dB at Gain = 27 dB 
0 ... 3 dB at Gain = 24 dB
0 ... 6 dB at Gain = 21 dB
0 ... 9 dB at Gain = 18 dB
0 ... 12 dB at Gain = 15 dB
0 ... 15 dB at Gain = 12 dB
Tilt set -0.5 dB tilt (default) allowed for entire gain
set range
0 dB tilt allowed for gain <26.2 dB
-1.0 dB tilt allowed for gain >12.8 dB
-1.5 dB tilt allowed for gain >13.6 dB
Default tilt setting -0.5 dB
Tilt accuracy +/- 0.3 dB for gain set range
12 dB ... 24 dB
+/- 0.5 dB for gain set range
> 24 dB
Max. total optical output power 20.5 dBm
Gain flatness 1.5 dBpp for gain set range 12 dB ... 24 dB
(over all conditions) 2 dBpp for gain set range > 24 dB

668 Module and System Specification


Chapter 10 Optical Amplifiers

Table 1180: Optical Specification (Continued)


Noise figure 5.5 dB at Gain = 27 dB
(Default tilt) 5.7 dB at Gain = 24 dB
6 dB at Gain = 21 dB
7.5 dB at Gain = 18 dB
10 dB at Gain = 15 dB
14 dB at Gain = 12 dB
Transient Response Transients up to 15 dB per 100 µs are
compressed to < 2.0dB with settling time of
<1ms.
Optical input return loss > 40 dB
Polarization dependent gain < 0.5 dB
OPR/OPT accuracy +/- 1 dB

The following table contains information about the system performance.

Table 1181: System Performance


Latency < 250 ns
Default output power per channel 4 dBm for 40 channel systems 
power into the transmission fiber 1 dBm for 80 channel systems

This table provides information about fault monitoring of the module in general.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 1182: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA

This table shows information about fault monitoring of the amplifier ports.

Table 1183: Fault Monitoring Amplifier Ports


Physical layer Laser failure;
Laser degrade (based on bias current);
Midstage fault;
Loss of signal (LOS);
Optical power Rx too high/too low (OPR);
Optical power Tx too high/too low (OPT);
Laser temperature too high/low

This table shows information about fault monitoring of the midstage ports.

Table 1184: Fault Monitoring Midstage Ports


Physical layer Laser failure;
Laser degrade (based on bias current);
Loss of signal (LOS);
Laser temperature too high/low

Module and System Specification 669


EDFA-C-D20-VLGC-DM

The following table provides information about performance monitoring of the


module in general.

Table 1185: Performance Monitoring - General


Equipment Module temperature (current value);
Gain block temperature (current value)

This table shows information about performance monitoring of the amplifier


ports.

Table 1186: Performance Monitoring Amplifier Ports


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM val- mean, high, OPR sampling rate
ues except current values; 50 ms to capture short events for
User configurable threshold crossing low, mean, and high)
alerts for OPR too high/too low available; Optical power Tx (current, low,
Fix threshold crossing alerts for OPT too mean, high, OPT sampling rate
high/too low available) 50 ms to capture short events for
low, mean, and high)
Laser bias current (current
value);
Laser temperature (current
value);
Laser operating hour

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Defect seconds (DS)

This table shows information about performance monitoring of the midstage


ports.

Table 1187: Performance Monitoring Midstage Ports


Physical layer Optical power Rx (current value);
Optical power Tx (current value);
Attenuation between stages (current value);
Attenuation of VOA (current value);
Laser bias current (current value);
Laser temperature (current value)
Laser operating hour

670 Module and System Specification


Chapter 10 Optical Amplifiers

EDFA-C-S26-VGC-DM
The EDFA-C-S26-VGC-DM is a variable gain-controlled, single-stage, high
output power, dual monitoring Erbium-doped fiber amplifier. The amplifier
module is capable of amplifying up to 81 channels in the C-band group.
A variable optical attenuator (VOA) at the input amplification stage controls the
gain and adjusts launch power.
Due to the high output power capabilities the network fiber must be connected
for the amplifier to function at full power. Pilot signals are used to verify the
connectivity of the network fiber. Pilots consist of either the OSC or Raman
pumps. If the EDFA-C-S26-VGC-DM is connected to another
EDFA-C-S26-VGC-DM, the OSC is the pilot signal. For this, the ALS of the
OSCM-PN has to be disabled. If the EDFA-C-S26-VGC-DM is connected to a
RAMAN-C10, the Raman pump is the pilot signal. The pilot signal must be
detected for the EDFA-C-S26-VGC-DM to operate at full output power.
The EDFA-C-S26-VGC-DM can be used as a booster amplifier or a
pre-amplifier for in-line amplifier configurations.
PS

This amplifier type must not be used in VSM protected configurations.


Note
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 1188 provides general information about the module and its environment.

Table 1188: General Information


Equipment type EDFA-S26
First release 10.3
Width 8 HP
Height 5 HU
Weight 1225 g (2.7 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 50°C ambient temperature 336,608 h
Typ. power consumption 30 W
Max. power consumption 50 W
Maximum RAM consumption on 98 Kbytes
NCU
Slot positions SH9HU: 3...17
SH7HU, SH7HU-R: 3...17
SH1HU: 1
NCU types NCU, NCU-II, NCU-II-P

Module and System Specification 671


EDFA-C-S26-VGC-DM

The following table contains information about all available ports.

Table 1189: Ports


Optical connector type LC
Fiber type G.652
U-R Upgrade Rx (C-band signal input)
Mon-R Upgrade Rx Tap (monitor for C-band signal power)
N-T Network Tx (amplified C-band signal output and
OSC counter direction input)
MON-T Network Tx Tap (amplified signal power monitor)
C-T Client Tx (OSC 1528 nm drop)
C-R Client Rx (OSC 1528 nm add)
N-R Network Rx (OSC counter direction output)
U-T Upgrade Tx (C-band signal output)

This table provides the optical specification directed from upgrade port (U-R) to
network port (N-T).

Table 1190: Optical Specification - Upgrade Port Rx to Network Port Tx 


(U-R to N-T)
Number of amplifiers 1 gain block
Passband 1529 nm ... 1562 nm
Max. total input power +3 dBm at 23.5 dB gain setting

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
+13 dBm at 13.5 dB gain setting
Max. total output power +26dBm, +/- 0.5 dBm (APR off)
+10 dBm (APR on)
Typ. total output power +26.5 dBm
Data signal LOS set -23 dBm
clear -21 dBm
Gain set range 13.5 dB ... 23.5 dB
Fixed gain tilt -2 dB
Gain ripple +/-1 dB with respect to -2 dB gain tilt
OSC pilot signal threshold for APR < -34 dBm
on (pump lasers off)
OSC pilot signal threshold for APR > -32 dBm
off (pump lasers on again)
Max. OSC pilot input signal -10 dBm
Raman pump pilot threshold for APR < -35 dBm
on (pump lasers off)
Raman pump pilot threshold for APR > -33 dBm
off (pump lasers on again)
Noise figure 8 dB at 23.5 dB gain setting
Optical return loss > 40 dB
Polarization dependent gain < 0.5 dB
Transient Response Transients up to 15 dB per 100 µs
are compressed to <4.0dB with
setting time of <1ms.

672 Module and System Specification


Chapter 10 Optical Amplifiers

Table 1190: Optical Specification - Upgrade Port Rx to Network Port Tx 


(U-R to N-T) (Continued)
Latency < 200 ns
OPR/OPT accuracy +/- 0.5 dB

This table provides the optical specification directed from network port (N-R) to
upgrade port (U-T).

Table 1191: Optical Specification - Network Port Rx to Upgrade Port Tx 


(N-R to U-T)
Insertion loss N-R to U-T < 1.0 dB
Latency < 200 ns

The EDFA-C-S26-VGC-DM is a Class 1M laser product with hazard


level 1M. According to IEC 60825-2, table D.14 the maximum
PS

allowable power limit is 27 dBm for systems in a wavelength range of


1529 nm to 1562 nm and with automatic power reduction or power
Note
shutdown.

The following table contains the optical specification of the client ports.

Table 1192: Optical Specification Client Ports


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

OSC center wavelength 1528 nm


Passband C-T < 13 nm
Passband C-R < 13 nm
Directivity C-T > 50 dB
Insertion loss C-R to N-T < 1.0 dB
Insertion loss N-R to C-T < 1.5 dB
Return loss C-T > 45 dB
Return loss C-R > 45 dB
Non-adjacent isolation N-R to C-T > 31 dB
Adjacent isolation N-R to C-T > 25 dB

This table provides the optical specification of the monitoring ports.

Table 1193: Optical Specification Monitoring Ports


Passband MON-R 1529 nm ... 1562 nm
MON-R coupling ratio 1% of U-R
Passband MON-T 1529 nm ... 1562 nm
MON-T coupling ratio 1% of N-T

Module and System Specification 673


EDFA-C-S26-VGC-DM

This table provides information about fault monitoring of the module in general.

Table 1194: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA

This table shows information about fault monitoring of the network ports.

Table 1195: Fault Monitoring Network Ports


Physical layer Pump laser failure;
Pump laser degrade (based on bias current);
Loss of signal (LOS);
Optical power Rx too high/too low (OPR);
Optical power Tx too high/too low (OPT);
Pump laser temperature too high/low

This table shows information about fault monitoring of the upgrade ports.

Table 1196: Fault Monitoring Upgrade Ports


Physical layer Optical power Rx too high/too low (OPR)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table provides information about performance monitoring of the
module in general.

Table 1197: Performance Monitoring - General


Equipment Module temperature (current value);
Gain block temperature (current value)

This table shows information about performance monitoring from upgrade port
to network port.

Table 1198: Performance Monitoring Upgrade Port to Network Port


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM val- mean, high);
ues except current values; Optical power Tx (current, low,
User configurable threshold crossing alerts mean, high);
for OPR too high/too low available; Pump laser bias current (current
Fix threshold crossing alerts for OPT too value);
high/too low available) Pump laser temperature (cur-
rent value);
Pump laser operating hour
Defect seconds (DS)

674 Module and System Specification


Chapter 10 Optical Amplifiers

EDFA-C-S26-VGCB-DM
The EDFA-C-S26-VGCB-DM is a variable gain-controlled, single-stage, high
output power, dual monitoring Erbium-doped fiber booster amplifier. The
amplifier module is capable of amplifying up to 81 channels in the C-band
group.
A variable optical attenuator (VOA) at the input amplification stage controls the
gain and adjusts launch power.
Due to the high output power capabilities the network fiber must be connected
for the amplifier to function at full power. Pilot signals are used to verify the
connectivity of the network fiber. Pilots consist of either the OSC or Raman
pumps. If the EDFA-C-S26-VGCB-DM is connected to another
EDFA-C-S26-VGCB-DM, the OSC is the pilot signal. For this, the ALS of the
OSCM-PN has to be disabled. If the EDFA-C-S26-VGCB-DM is connected to a
RAMAN-C10, the Raman pump is the pilot signal. The pilot signal must be
detected for the EDFA-C-S26-VGCB-DM to operate at full output power.
The EDFA-C-S26-VGCB-DM can be used as a booster amplifier or a
pre-amplifier for in-line amplifier configurations.
PS

This amplifier type must not be used in VSM protected configurations.


Note
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 1188 provides general information about the module and its environment.

Table 1199: General Information


Equipment type EDFA-S26
First release 11.2.3
Width 8 HP
Height 5 HU
Weight 1225 g (2.7 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 50°C ambient temperature 336,608 h
Typ. power consumption 30 W
Max. power consumption 50 W
Maximum RAM consumption on 98 Kbytes
NCU
Slot positions SH9HU: 3...17
SH7HU, SH7HU-R: 3...17
SH1HU: 1
NCU types NCU, NCU-II, NCU-II-P

Module and System Specification 675


EDFA-C-S26-VGCB-DM

The following table contains information about all available ports.

Table 1200: Ports


Optical connector type LC
Fiber type G.652
U-R Upgrade Rx (C-band signal input)
Mon-R Upgrade Rx Tap (monitor for C-band signal power)
N-T Network Tx (amplified C-band signal output and
OSC counter direction input)
MON-T Network Tx Tap (amplified signal power monitor)
C-T Client Tx (OSC 1528.77 nm drop)
C-R Client Rx (OSC 1528.77 nm add)
N-R Network Rx (Network C-band signal input and OSC
counter direction output)
U-T Upgrade Tx (C-band signal output)

This table provides the optical specification directed from upgrade port (U-R) to
network port (N-T).

Table 1201: Optical Specification - Upgrade Port Rx to Network Port Tx 


(U-R to N-T)
Number of amplifiers 1 gain block
Passband 1529 nm ... 1562 nm

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Max. total input power +3 dBm at 23 dB gain setting
+13 dBm at 13 dB gain setting
Min. total input power -20 dBm at 23 dB gain setting
Max. total output power +26 dBm, +/- 0.5 dBm (APR off)
+10 dBm (APR on)
Typ. total output power +26.5 dBm
Data signal LOS set -23 dBm
clear -21 dBm
Gain set range 13.5 dB ... 23.5 dB
Fixed gain tilt -2 dB
Gain ripple +/-1 dB with respect to -2 dB gain tilt
OSC pilot signal threshold for APR < -38 dBm (pump lasers off)
on < -40 dBm (pump lasers on)
OSC pilot signal threshold for APR > -36 dBm (pump lasers off)
off > -38 dBm (pump lasers on again)
Max. OSC pilot input signal -10 dBm
Raman pump pilot threshold for APR < -35 dBm
on (pump lasers off)
Raman pump pilot threshold for APR > -33 dBm
off (pump lasers on again)
Noise figure 8 dB at 23.5 dB gain setting
Optical return loss > 40 dB
Polarization dependent gain < 0.5 dB

676 Module and System Specification


Chapter 10 Optical Amplifiers

Table 1201: Optical Specification - Upgrade Port Rx to Network Port Tx 


(U-R to N-T) (Continued)
Transient Response Transients up to 15 dB per 100 µs
are compressed to <4.0dB with
setting time of <1ms.
Latency < 200 ns
OPR/OPT accuracy +/- 0.5 dB

This table provides the optical specification directed from network port (N-R) to
upgrade port (U-T).

Table 1202: Optical Specification - Network Port Rx to Upgrade Port Tx 


(N-R to U-T)
Insertion loss N-R to U-T < 1.0 dB
Latency < 200 ns

The EDFA-C-S26-VGCB-DM is a Class 1M laser product with hazard


level 1M. According to IEC 60825-2, table D.14 the maximum
PS

allowable power limit is 27 dBm for systems in a wavelength range of


1529 nm to 1562 nm and with automatic power reduction or power
Note
shutdown.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

The following table contains the optical specification of the client ports.

Table 1203: Optical Specification Client Ports


OSC center wavelength 1528.77 nm
Passband C-T 250 pm
Passband C-R 250 pm
Directivity C-T > 50 dB
Insertion loss C-R to N-T < 1.0 dB
Insertion loss N-R to C-T < 1.5 dB
Return loss C-T > 45 dB
Return loss C-R > 45 dB
Non-adjacent isolation N-R to C-T > 31 dB
Adjacent isolation N-R to C-T > 25 dB

This table provides the optical specification of the monitoring ports.

Table 1204: Optical Specification Monitoring Ports


Passband MON-R 1529 nm ... 1562 nm
MON-R coupling ratio 1% of U-R
Passband MON-T 1529 nm ... 1562 nm
MON-T coupling ratio 1% of N-T

Module and System Specification 677


EDFA-C-S26-VGCB-DM

This table provides information about fault monitoring of the module in general.

Table 1205: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA

This table shows information about fault monitoring of the network ports.

Table 1206: Fault Monitoring Network Ports


Physical layer Pump laser failure;
Pump laser degrade (based on bias current);
Loss of signal (LOS);
Optical power Rx too high/too low (OPR);
Optical power Tx too high/too low (OPT);
Pump laser temperature too high/low

This table shows information about fault monitoring of the upgrade ports.

Table 1207: Fault Monitoring Upgrade Ports


Physical layer Optical power Rx too high/too low (OPR)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table provides information about performance monitoring of the
module in general.

Table 1208: Performance Monitoring - General


Equipment Module temperature (current value);
Gain block temperature (current value)

This table shows information about performance monitoring from upgrade port
to network port.

Table 1209: Performance Monitoring Upgrade Port to Network Port


Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM val- mean, high, OPR sampling rate
ues except current values; 50 ms to capture short events for
User configurable threshold crossing alerts low, mean, and high)
for OPR too high/too low available; Optical power Tx (current, low,
Fix threshold crossing alerts for OPT too mean, high, OPT sampling rate
high/too low available) 50 ms to capture short events for
low, mean, and high)
Pump laser bias current (current
value);
Pump laser temperature (cur-
rent value);
Pump laser operating hour
Defect seconds (DS)

678 Module and System Specification


Chapter 10 Optical Amplifiers

RAMAN-C10
The RAMAN-C10 is a fiber Raman amplifier with constant pump power used for
backward distributed Raman amplification in DWDM networks. It is capable of
amplifying up to 81 channels in the C band.
The power level of the outgoing Raman amplified signal may be monitored. The
RAMAN-C10 can be used as pre-amplifier stage in front of an EDFA module
(inline, pre- or booster amplifier) to increase its input power. In combination with
EDFA-C-D20-VGC-DM, the Raman amplifier is capable for up to 50 dB span
loss.
Due to the high output power capabilities, the network fiber must be connected
for the amplifier to function at full power. The 1528.77 nm OSC signal from the
OSCM-PN is used as a pilot signal to verify the integrity of the network fiber. For
this, the ALS of the OSCM-PN has to be disabled.
PS

This amplifier type must not be used in VSM protected configurations.


Note

Table 1210 provides general information about the module and its environment.

Table 1210: General Information


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Equipment type RAMAN


First release 8.2
Width 4 HP
Height 5 HU
Weight 600 g (1.3 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 433,179 h
Typ. power consumption 30 W
Max. power consumption 55 W
Maximum RAM consumption on 84 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P

The following table contains information about all available ports.

Table 1211: Ports


Optical connector type LC
Fiber type G.652

Module and System Specification 679


RAMAN-C10

Table 1211: Ports (Continued)


N-R Network Rx (RAMAN Laser out)
U-T Upgrade Tx (amplified signal out)
MON-R Upgrade Tx Tap (amplified signal
monitor)
C-T Client Tx (OSC drop)
U-R Upgrade Rx (counter direction input)
N-T Network Tx (counter direction output)
Mon-T Network Tx Tap (monitor for counter
direction output)
C-R Client Rx (OSC add)

Figure 12: Functional Blockdiagram


1450 nm
Pump Reflected Pump pump laser 1
monitor monitor Signal monitor
PD1 PD2 U-T
1450 nm PD3
PBC pump laser 2

MON-R
Tap coupler Tap
Transmission fiber
Pump
OSC drop filter Tap
power N-R U-T
GFF
Data signals + Raman
OSC signal 1450/1550 nm Tap

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
PD4 amplified
from the network WDM
Tap data signals
C-T Signal power
monitor
OSC signal OSC
PD5 monitor
C-R

Tap OSC add


N-T filter U-R

Data signals + Data signals


OSC signal
to the network
MON-T

The following table contains the optical specification of the upgrade ports.

Table 1212: Optical Specification Upgrade Ports


Passband 1529 nm ... 1562 nm
Max. total output power at U-T + 5 dBm
(pump on)
Insertion loss N-R to U-T < 2 dB
Insertion loss U-R to N-T < 1.5 dB
Return loss > 40 dB
Latency N-R to U-T < 50 ns up to HW 2.01
< 30 ns from HW 3.01

680 Module and System Specification


Chapter 10 Optical Amplifiers

This table provides the optical specification of the network ports.

Table 1213: Optical Specification Network Ports


Number of amplifiers 1 gain block
Passband 1528 nm ... 1563 nm
Min. data signal per channel input -45 dBm
power at N-R (without ASE and
RAMAN gain)
Min. data signal total input power at -40 dBm
N-R (without ASE and RAMAN
gain)
Max. data signal total input power at -5 dBm
N-R (pump off)
Min. OSC input power at N-R -47 dBm
(pump off)
Max. OSC input power at N-R -18 dBm
(pump off)
Data signal LOS (pump on) -40 dBm
Data signal LOS (pump off) -45 dBm
OSC input LOS (pump off) -47 dBm
Total output pump power at N-R 23 ... 27.6 dBm1
Net signal gain for G.652 fiber 11 dB (for input power -45 ... -10 dBm)
10 dB (for input power -10 ... -5 dBm)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Net OSC gain 11 dB


Gain flatness < 1.2 dBpp
Effective noise figure < -1 dB
Back reflection set range -18 ... -30 dB
Optical return loss > 40 dB
Polarization dependent gain < 0.5 dB
Temperature dependent gain < 1 dB
Latency U-R to N-T < 30 ns up to HW 2.01
< 20 ns from HW 3.01
OPR/OPT accuracy +/- 0.5 dB
1. The RAMAN-C10 is a Class 1M laser product with hazard level 1M.
According to IEC 60825-2 the maximum allowable power limit is 28.1 dBm
for systems in a wavelength range of 1400 to 1500 nm with automatic power
shutdown and a shutdown time below 1 second.

For a span loss between 21 dB and 28 dB, please add an attenuator


PS

of 7 dB at the transmitter output of the OSC.


Note

Module and System Specification 681


RAMAN-C10

The following table contains the optical specification of the client ports.

Table 1214: Optical Specification Client Ports


OSC center wavelength 1528.77 nm
Passband C-T 250 pm (31.25 GHz)
Passband C-R 250 pm (31.25 GHz)
Directivity C-T > 50 dB
Insertion loss C-R to N-T < 1 dB
Insertion loss N-R to C-T < 1.5 dB
Return loss C-T > 45 dB
Return loss C-R > 45 dB
Non-adjacent isolation N-R to C-R > 45 dB
Adjacent isolation N-R to C-R > 32 dB
Latency C-R to N-T < 25 ns up to HW 2.01
< 20 ns from HW 3.01
Latency N-R to C-T < 25 ns up to HW 2.01
< 20 ns from HW 3.01

This table provides the optical specification of the monitoring ports.

Table 1215: Optical Specification Monitoring port


Passband MON-R 1529 nm ... 1562 nm
MON-R coupling ratio 1% of U-T

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Passband MON-T 1529 nm ... 1562 nm
MON-T coupling ratio 1% of N-T

This table provides information about fault monitoring of the module in general.

Table 1216: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA

This table shows information about fault monitoring of the network ports.

Table 1217: Fault Monitoring Network Ports


Physical layer Pump laser failure;
Pump laser degrade (based on bias current);
Loss of signal (LOS);
OSC power Rx too high/too low;
Pump power back reflection too high;
ASE built-up too low;
Pump optical power Tx too high/too low (OPT);
Pump laser temperature too high/low

682 Module and System Specification


Chapter 10 Optical Amplifiers

This table shows information about fault monitoring of the upgrade ports.

Table 1218: Fault Monitoring Upgrade Ports


Physical layer Optical power Tx too high/too low (OPT);
Optical output power limited by APR

The following table provides information about performance monitoring of the


module in general.

Table 1219: Performance Monitoring - General


Equipment Module temperature (current value);
Raman pump block temperature (current value)

This table shows information about performance monitoring of the network


ports.

Table 1220: Performance Monitoring Network Ports


Physical layer Pump laser bias current (current value);
(15 min/24 h records available Pump laser temperature (current value);
for PM values except current OSC Raman on/off gain (current, low,
values; mean, high);
User configurable threshold Back reflection (current, low, mean, high)
crossing alerts for OPR too Total pump laser optical power Tx (current,
high/too low available; low, mean, high);
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Fix threshold crossing alerts for OSC optical power Rx (current, low, mean,
OPT too high/too low available) high);
Defect seconds (DS)

This table shows information about performance monitoring of the upgrade


ports.

Table 1221: Performance Monitoring Upgrade Ports


Physical layer Optical power Tx (current, low, mean, high)
OPT sampling rate 50 ms to capture short events for low,
mean, and high)
Estimated net signal Raman gain (current, low, mean, high)

Module and System Specification 683


2RAMAN-C15-LL

2RAMAN-C15-LL
The 2RAMAN-C15-LL is a dual Raman amplifier module optimized to be used in
low latency networks. It offers minimum ASE noise and maximum flatness for
extended links. Each Raman is designed to operate over spans supporting 81
C band channels with span budgets of 15 dB to 30 dB. The Raman operates
without EDFA booster amplifiers. Each module contains a forward (FWD) and a
backward (BWD) facing Raman amplifier. The gain on each of the two amplifiers
can be set independently from 7 dB to 15 dB.
The module is designed to operate with both Raman amplifiers turned on. The
forward Raman cannot be used without the backward Raman because it will not
turn on without having the backward Raman running on the same span. The
backward Raman does not need the forward Raman, but it does need to receive
the 1528.77 nm OSC signal, which is added to the built-in OSC filter at the
upstream forward Raman amp C-R port. The ALS of the OSCM-PN has to be
disabled.
The module occupies two slots in a FSP 3000R7 7HU and 9HU shelves.

The 2RAMAN-C15-LL is intended for special applications. This


amplifier type must not be used in VSM protected configurations. For
PS

system planning, please contact ADVA Optical Networking Technical


Note Services.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table provides general information about the module and its
environment.

Table 1222: General Information


Equipment type 2RAMAN-C15-LL
First release 10.3
Width 8 HP
Height 5 HU
Max. weight 1309 g (2.9 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 224,366 h
Typ. power consumption 50 W (high Gain)
Max. power consumption 100 W
Maximum RAM consumption on 126 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
NCU types NCU, NCU-II, NCU-II-P

684 Module and System Specification


Chapter 10 Optical Amplifiers

The following table contains information about all available ports

Table 1223: Ports


Optical connector type LC
Fiber type G.652
N-R Network Rx (BWD Raman Laser out)
U-T Upgrade Tx (BWD Raman amplified signal out)
MON-R Upgrade Tx Tap (BWD Raman amplified signal
monitor)
C-T Client Tx (OSC drop)
U-R Upgrade Rx (FWD Raman input)
N-T Network Tx (FWD Raman output)
MON-T Network Tx Tap (monitor for FWD Raman output)
C-R Client Rx (OSC add)

Figure 13: Functional Block diagram


Tap
Mon-R

Backward RAMAN
Output
ASE
PD
PD

OSC Drop Tap Filter

Network Rx Upgrade Tx
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

N-R U-T

Pump OSC
PD PD

Client Tx
Raman Pumps C-T

Client Rx
C-R

OSC
PD

Network Tx GFF Upgrade Rx


N-T U-R

Pump
PD

ASE
PD
Raman Pumps Input
PD
Forward RAMAN
Tap
Mon-T

Module and System Specification 685


2RAMAN-C15-LL

The following table contains the optical specification of the upgrade ports.

Table 1224: Optical Specification Upgrade Ports


Passband 1529 nm ... 1563 nm
Max. total output power at U-T + 12 dBm
(pump on)
Max. total input power • 2 dBm at 15 dB gain (G.652 (SMF28,
Allwave), ULL (Ultra-Low Loss), G.655
(Teralight, TW-Reach) fiber)
• 6 dBm at 15 dB gain (TW-RS fiber)
Min. total input power -20 dBm
Insertion loss N-R to U-T 2 dB
Insertion loss U-R to N-T 2.3 dB
Return loss > 40 dB
Latency N-R to U-T < 10 ns
Latency U-R to N-T < 12 ns

This table provides the optical specification of the network ports for the BWD
Raman.

Table 1225: Optical Specification Network Ports BWD Raman


Number of amplifiers 1
Passband 1529 nm ... 1563 nm

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Supported transmission fiber type G.652 (SMF28, Allwave), G.655
(TW-RS, Teralight, TW-Reach),
ULL (Ultra-Low Loss) fiber
Min. gain for all supported fiber types 7 dB
Max. gain ranges for G.652 (SMF28, 9.5 dB to 14.5 dB1
Allwave), ULL (Ultra-Low Loss) fiber
Max. gain for G.655 (TW-RS, Teralight, 15 dB1
TW-Reach)
Min. data signal total input power at N-R -36 dBm
(without ASE and RAMAN gain)
Max. data signal total input power at N-R -3 dBm at 15 dB gain 
(pump off) (Input + Gain < 12 dBm)
Min. OSC input power at N-R (pump off) -38 dBm
Max. OSC input power at N-R (pump off) -19 dBm
Data signal LOS (pump off) raise at -39 dBm
clear at -37 dBm
OSC input LOS (pump off) raise at -40 dBm
clear at -39 dBm
Max total output pump power at N-R 30 dBm2
Net OSC gain 7 dB... 15 dB
Gain flatness < 1.5 dBpp
Tilt Setable for: -2.0, -1.5, -1.0 dB
(default = -1.0 dB)
Effective noise figure < -1.0 dB at 15 dB gain
Optical return loss > 40 dB
Polarization dependent gain < 0.5 dB

686 Module and System Specification


Chapter 10 Optical Amplifiers

Table 1225: Optical Specification Network Ports (Continued)BWD Raman


Temperature dependent gain < 1.0 dB
Polarization mode dispersion < 0.5 ps
Latency N-R to U-T < 10 ns
OPR/OPT accuracy +/- 0.5 dB
1. Maximum gain values assume connector loss to be 1dB or lower.
2. The 2RAMAN-C15-LL is a Class 1M laser product with hazard level 1M.
According to IEC 60825-2 the maximum allowable power limit is 31.1 dBm
for systems in a wavelength range of 1400 to 1500 nm with automatic power
shutdown and a shutdown time below 0.5 second.

This table provides the optical specification of the network ports for the FWD
Raman.

For a span loss less than 20 dB, please add an attenuator of 5 dB at


PS

the transmitter output of the OSC.


Note

Table 1226: Optical Specification Network Ports FWD Raman


Number of amplifiers 1
Passband 1529 nm ... 1563 nm
Supported transmission fiber type G.652 (SMF28, Allwave), G.655
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

(TW-RS, Teralight, TW-Reach),


ULL (Ultra-Low Loss) fiber
Min. gain for all supported fiber types 7 dB
Max. gain range for G.652 (SMF28, 10 dB to 15 dB1
Allwave), ULL (Ultra-Low Loss) fiber
Max. gain for G.655 (TW-RS, Teralight, 15 dB1
TW-Reach)
Min. data signal total input power at -20 dBm
U-R
Max. data signal total input power at • 2 dBm at 15 dB gain (G.652
U-R (SMF28, Allwave), ULL
(Ultra-Low Loss), G.655
(Teralight, TW-Reach) fiber)
• 6 dBm at 15 dB gain (TW-RS
fiber)
Min. OSC input power at C-R (depends Configured OSC OPT + 1 dB
on user-configured OSC OPT)
Max. OSC output at C-R (depends on Configured OSC OPT + 25 dB
user-configured OSC OPT)
Data signal LOS raise at -23 dBm
clear at -21 dBm
Max. total output pump power at N-T 30 dBm2
Net OSC gain 7 dB ... 15 dB
Gain flatness < 1.2 dBpp
Optical return loss > 40 dB

Module and System Specification 687


2RAMAN-C15-LL

Table 1226: Optical Specification Network Ports FWD Raman (Continued)


Polarization dependent gain < 0.5 dB
Temperature dependent gain < 1.0 dB
Polarization mode dispersion < 0.5 ps
Latency U-R to N-T < 12 ns
OPR/OPT accuracy +/- 0.5 dB
1. Maximum gain values assume connector loss to be 1dB or lower.
2. The 2RAMAN-C15-LL is a Class 1M laser product with hazard level 1M.
According to IEC 60825-2 the maximum allowable power limit is 31.1 dBm
for systems in a wavelength range of 1400 to 1500 nm with automatic power
shutdown and a shutdown time below 0.5 second.

The following table contains the optical specification of the client ports.

Table 1227: Optical Specification Client Ports


OSC center wavelength 1528.77 nm
Passband C-T 250 pm (31.25 GHz)
Passband C-R 250 pm (31.25 GHz)
Insertion loss C-R to N-T < 1 dB
Insertion loss N-R to C-T < 1.5 dB
Return loss C-T > 45 dB
Return loss C-R > 45 dB
Non-adjacent isolation N-R to C-R > 45 dB

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Adjacent isolation N-R to C-R > 32 dB

This table provides the optical specification of the monitoring ports.

Table 1228: Optical Specification Monitoring port


Passband MON-R 1529 nm ... 1563 nm
MON-R coupling ratio 1% of U-T
Passband MON-T 1529 nm ... 1563 nm
MON-T coupling ratio 1% of N-T

This table provides information about fault monitoring of the module in general.

Table 1229: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA
Board temperature too high

688 Module and System Specification


Chapter 10 Optical Amplifiers

This table shows information about fault monitoring of the network ports.

Table 1230: Fault Monitoring Network Ports


Physical layer Loss of signal (LOS);
Loss of OSC (LOSC);
OSC optical power control high/how;
Amplifier abnormal (FWD Raman)

This table shows information about fault monitoring of the upgrade ports.

Table 1231: Fault Monitoring Upgrade Ports


Physical layer Optical power Rx too high/low (OPR);
Loss of signal (LOS);
Amplifier abnormal (BWD Raman);
Optical power Tx too high/low (OPT)

This table lists the BWD Raman amplifier faults.

Table 1232: Fault Monitoring - BWD Raman


Amplifier Faults ASE table building;
ASE table not available (NA);
ASE table fail due to pilot;
ASE table fail due to signal;
ASE table fail due to ASE;
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

FWD ASE pilot ON;


FWD ASE pilot FAIL;
Loss of pilot (Pilot LOS);
Pilot too high;
Gain/tilt not reachable;
Pump laser end-of-life (EOL);
Auto power shutdown;
Auto shutdown due to ASE table;
Auto shutdown due to temperature;
Laser 1/2/3/4 temp too low/high

Module and System Specification 689


2RAMAN-C15-LL

This table lists the FWD Raman amplifier faults.

Table 1233: Fault Monitoring - FWD Raman


Amplifier Faults ASE table building;
ASE table not available (NA);
ASE table fail due to pilot;
ASE table fail due to signal;
ASE table fail due to ASE;
ASE table fail due to back-reflection;
Loss of pilot (Pilot LOS);
Pilot too high;
Gain/tilt not reachable;
Pump laser end-of-life (EOL);
Auto power shutdown;
Auto shutdown due to ASE table;
Auto shutdown due to temperature;
Laser 1/2/3/4 temp too low/high

The following table provides information about performance monitoring of the


module in general.

Table 1234: Performance Monitoring - General


Equipment Module temperature (current value);

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table shows information about performance monitoring of the network
ports.

Table 1235: Performance Monitoring Network Ports


Physical layer OSC optical power Tx (current, low,
(15 min/24 h records available for PM mean, high)
values except current values;

Table below shows information about performance monitoring of the upgrade


ports.

Table 1236: Performance Monitoring Upgrade Ports


Physical layer Optical power Tx (current,
(15 min/24 h records available for PM values low, mean, high);
except current values; Optical power Rx (current,
User configurable threshold low, mean, high)
crossing alerts for OPR/OPT too
high/too low available)

690 Module and System Specification


Chapter 10 Optical Amplifiers

This table shows information about performance monitoring of the BWD Raman
amplifier.

Table 1237: Performance Monitoring - BWD Raman


Equipment Laser 1/2/3/4 temperature;
Laser 1/2/3/4 bias current;
Raman pump power;
Operating hours;
Defect seconds (DS)

This table shows information about performance monitoring of the FWD Raman
amplifier.

Table 1238: Performance Monitoring - FWD Raman


Equipment Laser 1/2/3/4 temperature;
Laser 1/2/3/4 bias current;
Raman pump power;
Operating hours;
Defect seconds (DS);
Backreflection (current, low, mean, high)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 691


AMP-S20H-C15

AMP-S20H-C15
The AMP-S20H-C15 module is an integrated high gain EDFA and BWD Raman
amplifier pair designed to operate over spans supporting 96 C band channels. It
offers minimum ASE noise and maximum flatness for moderate links. If the span
is relatively short or a pre-amp/post amp is needed, the Raman amplifier is not
needed. The EDFA may be used independently.
Integration of two amplifiers on the same module reduces the number of individ-
ual amplifier types needed. Usage of the EDFA or Raman amplifiers is depen-
dent on the application. The module allows usage of the EDFA amplifier alone,
or both the EDFA and BWD Raman. If the BWD Raman is used, the EDFA must
also be used because when the EDFA pumps are turned off the signal path is
severely attenuated. If the EDFA is used alone, there is a 2 dB loss through the
BWD Raman without the pumps on.
The amplifier also has improved transient control, allowing for better regulation
of variations in channel amplitudes.
Due to the high output power capabilities, the network fiber must be connected
for the amplifier to function at full power. The 1528.77 nm OSC signal from the
OSCM-PN is used as a pilot signal to verify the integrity of the network fiber. For
this, the ALS of the OSCM-PN has to be disabled.
The module occupies two slots in a FSP 3000R7 7HU and 9HU shelves.
The AMP-S20H-C15 is intended for special applications. This

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
amplifier type must not be used in VSM protected configurations. For
PS

system planning, please contact ADVA Optical Networking Technical


Note Services.

692 Module and System Specification


Chapter 10 Optical Amplifiers

Table 1239 provides general information about the module and its environment.

Table 1239: General Information


Equipment type AMP-SHGCV
First release 11.2
Width 8 HP
Height 5 HU
Max. weight 1335 g (2.94 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 299,940 h
Typ. power consumption 50 W (high Gain)
Max. power consumption 90 W
Maximum RAM consumption on 186 Kbytes
NCU
Slot positions SH9HU: 3...17
SH7HU, SH7HU-R: 3...18
NCU types NCU, NCU-II, NCU-II-P

The following table contains information about all available ports.


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 1240: Ports


Optical connector type LC
Fiber type G.652
N-R Network Rx (BWD Raman Laser out)
U-T Upgrade Tx (BWD Raman amplified signal out)
MON-R Upgrade Tx Tap (BWD Raman amplified signal
monitor)
C-T Client Tx (OSC drop)
U-R Upgrade Rx (EDFA input)
N-T Network Tx (EDFA output)
MON-T Network Tx Tap (monitor for EDFA input)
C-R Client Rx (OSC add)

Module and System Specification 693


AMP-S20H-C15

Figure 14: AMP-S20H-C15 Functional Block diagram


Mon

EDFA Directon C-Band Signal Direction

Fiber Detection Fib Det EDFA


Link Direction
Rx

Fib Det Mon OSC Signal


R T
FIL Tap FIL
l U N and
T R OSC
C band Signal Direction

OSC Directon

OSC OSC
R PD
Level Set
C T OSC
PD
OSC Directon

C band Signal Direction

Fib Det Mon OSC


FIL FIL
FIL Tap

Fiber Detection Fib Det


Link Direction Tx
BWD Raman
BWD Raman Pump Directon

Mon

This table provides the optical specification of the network ports for the BWD
Raman.

Table 1241: Optical Specification N-R to U-T BWD Raman

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Passband 1528.5 nm ... 1568.5 nm
Supported transmission fiber type G.652 (SMF28, Allwave), G.655
(LEAF, TW-RS, Teralight,
TW-Reach), ULL (Ultra-Low
Loss) fiber
Standard gain range for all fiber types. 9 dB to 15 dB2
Extended gain range 9 dB to 18 dB3
Min. data signal total input power at N-R -36 dBm
(without ASE and RAMAN gain)
Max. data signal total input power at N-R 0 dBm at gain = 15 dB,
(pump off) 3 dBm at gain = 12 dB,
6 dBm at gain = 9 dB
Min. OSC input power at N-R -38 dBm
Max. OSC input power at N-R (pump off) -19 dBm
Data signal LOS raise at -38 dBm
clear at -36 dBm
OSC input LOS raise at -39 dBm
clear at -38 dBm
Max total output pump power at N-R 30 dBm1
Gain flatness < 1.5 dBpp
Tilt Setable for: -2.0, -1.5, -1.0 dB
(default = -1.0 dB)
Effective noise figure < -1.0 dB at 15 dB gain
Insertion loss N-R to U-T 2 dB
Optical return loss > 40 dB

694 Module and System Specification


Chapter 10 Optical Amplifiers

Table 1241: Optical Specification N-R to U-T BWD Raman (Continued)


Polarization dependent gain < 0.5 dB
Polarization mode dispersion < 0.5 ps
Latency N-R to U-T < 50 ns
OPR/OPT accuracy +/- 1.0dB
1. The Amp-S20H-C15 is a Class 1M laser product with hazard level 1M.
According to IEC 60825-2 the maximum allowable power limit is 31.1 dBm
for systems in a wavelength range of 1400 to 1500 nm with automatic power
shutdown and a shutdown time below 0.5 second.
2.The maximum achievable gain may be less than 15 dB, depending on the
fiber type and connector loss.
3. Extended gain range may not meet all standard specs and should only be
used under special circumstances.

This table provides the optical specification for the EDFA directed from upgrade
port (U-R) to network port (N-T).

Table 1242: Optical Specification - U-R to N-T for EDFA


Passband 1528.5 nm ... 1568.5 nm
Max. total input power +0 dBm at gain = 20 dB
+3 dBm at gain = 17 dB
+6 dBm at gain = 14 dB
+9 dBm at gain = 11 dB
Max. total output power +21 dBm (OPT power limit will
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

attempt to regulate at 20.8 dBm)


Data signal LOS -28 dBm
Gain set range 11 dB ... 20 dB
Fixed gain tilt 0 dB
Gain ripple +/-1 dB
Output VOA Level Set Range 0 dB to 12dB
Output VOA Level Set Accuracy +/-0.5 dB
Noise figure 5.5 dB at gain = 20 dB
6.0 dB at gain = 17 dB
7.5 dB at gain = 14 dB
9.5 dB at gain = 11 dB
Optical return loss > 40 dB
Polarization dependent gain < 0.5 dB
Transient Response Transients up to 15 dB per 100 µs
are compressed to <2.5dB with
setting time of <1ms.
Latency U-R to N-T < 250 ns
OPR/OPT accuracy +/- 1 dB

The following table contains the optical specification of the client port.

Table 1243: Optical Specification Client Ports


OSC center wavelength 1528.77 nm
Passband C-T < 250 pm
Passband C-R < 250 pm

Module and System Specification 695


AMP-S20H-C15

Table 1243: Optical Specification Client Ports (Continued)


Insertion loss C-R to N-T 3 dB ... 25 dB (adjustable)
Set OSC launch power to -6 dBm ... +2 dBm.
Insertion loss N-R to C-T 2 dB
Return loss C-T > 45 dB
Return loss C-R > 45 dB

This table provides the optical specification of the monitoring ports.

Table 1244: Optical Specification Monitoring port


Passband MON-R 1528.5 nm ... 1568.5 nm
MON-R coupling ratio 1% of U-T
Passband MON-T 1528.5 nm ... 1568.5 nm
MON-T coupling ratio 1% of N-T

This table provides information about fault monitoring of the module in general.

Table 1245: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Board temperature too high

This table shows information about fault monitoring of the network port.

Table 1246: Fault Monitoring Network Ports


Physical layer Loss of signal (LOS);
Loss of OSC (LOSC);
OSC optical power control high/low;
EDFA amplifier pumps off
EDFA attenuator fail

This table shows information about fault monitoring of the upgrade port.

Table 1247: Fault Monitoring Upgrade Ports


Physical layer BWD amplifier is enabled but shut down. U
port is abnormal and degraded (AMPANR);
Optical power Rx too high/low (OPR);
Loss of signal (LOS);
Optical power Tx too high/low (OPT)

696 Module and System Specification


Chapter 10 Optical Amplifiers

This table lists the BWD Raman amplifier faults.

Table 1248: Fault Monitoring - BWD Raman


Amplifier Faults ASE table building;
ASE table not available (NA);
ASE table fail due to pilot;
ASE table fail due to signal;
ASE table fail due to ASE;
Loss of pilot (Pilot LOS);
Pilot too high;
Gain/tilt not reachable;
Pump laser end-of-life (EOL);
Auto power shutdown;
Auto shutdown due to ASE table;
Auto shutdown due to temperature;
Laser 1/2/3/4 temp too low/high

This table lists the EDFA amplifier faults.

Table 1249: Fault Monitoring - EDFA Amplifier


Amplifier Faults Gain Tilt Abnormal;
End of Life;
Transmit Power is Limited;
Auto Shut down due to high pump temperature;
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Auto Shut down due to inability to regulate exces-


sive OPT;
Noise reduction APR applied due to LOS;
EDFA Attenuator Fail;

The following table provides information about performance monitoring of the


module in general.

Table 1250: Performance Monitoring - General


Equipment Module temperature (current value);

This table shows information about performance monitoring of the network port.

Table 1251: Performance Monitoring Network Ports


Physical layer OSC optical power Tx (current, low,
(15 min/24 h records available for PM mean, high);
values except current values; EDFA transmit output power current,
low, mean, high)

Module and System Specification 697


AMP-S20H-C15

Table below shows information about performance monitoring of the upgrade


port.

Table 1252: Performance Monitoring Upgrade Ports


Physical layer Optical power Rx (current,
(15 min/24 h records available for PM values low, mean, high, OPR sam-
except current values; pling rate 50 ms to capture
User configurable threshold short events for low, mean,
crossing alerts for OPR/OPT too and high)
high/too low available) Optical power Tx (current,
low, mean, high, OPT sam-
pling rate 50 ms to capture
short events for low, mean,
and high)

This table shows information about performance monitoring of the BWD Raman
amplifier.

Table 1253: Performance Monitoring - BWD Raman


Equipment Laser 1/2/3/4 temperature;
Laser 1/2/3/4 bias current;
Raman pump power;
Operating hours;

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Defect seconds (DS)
Back Reflection (current, low, mean, high);
Back Reflection TCA (high, low)

This table shows information about performance monitoring of the FWD Raman
amplifier.

Table 1254: Performance Monitoring - EDFA amplifier


Equipment Laser 1and 2 temperature;
Laser 1 and 2 bias current;
Defect Seconds (DS);
Optical output power (current value);
Gain total; gain current value from combination of
EDFA
EDFA Attenuator current attenuation applied by
VOA

698 Module and System Specification


Chapter 10 Optical Amplifiers

AMP-S20L-C15
The AMP-S20L-C15 module is an integrated low gain EDFA and BWD Raman
amplifier pair designed to operate over spans supporting 96 C band channels. It
offers minimum ASE noise and maximum flatness for moderate links. If the span
is relatively short or a pre-amp/post amp is needed, the Raman amplifier is not
needed. The EDFA may be used independently.
Integration of two amplifiers on the same module reduces the number of individ-
ual amplifier types needed. Usage of the EDFA or Raman amplifiers is depen-
dent on the application. The module allows usage of the EDFA amplifier alone,
or both the EDFA and BWD Raman. If the BWD Raman is used, the EDFA must
also be used because when the EDFA pumps are turned off the signal path is
severely attenuated. If the EDFA is used alone, there is a 2 dB loss through the
BWD Raman without the pumps on.
The amplifier also has improved transient control, allowing for better regulation
of variations in channel amplitudes.
Due to the high output power capabilities, the network fiber must be connected
for the amplifier to function at full power. The 1528.77 nm OSC signal from the
OSCM-PN is used as a pilot signal to verify the integrity of the network fiber. For
this, the ALS of the OSCM-PN has to be disabled.
The module occupies two slots in a FSP 3000R7 7HU and 9HU shelves.
ADVA Optical Networking does not support using the AMP-S20L-C15
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

in a 9ROADM-C96/0/OPM node as a booster or pre-amplifier. The


Amp-S20H-C15 is recommended for this type of application.
PS

The AMP-S20L-C15 amplifier must not be used in VSM protected


configurations.
Note
For system planning, please contact ADVA Optical Networking
Technical Services.

Module and System Specification 699


AMP-S20L-C15

Table 1255 provides general information about the module and its environment.

Table 1255: General Information


Equipment type AMP-SLGCV
First release 11.2
Width 8 HP
Height 5 HU
Max. weight 1335 g (2.94 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 299,940 h
Typ. power consumption 50 W
Max. power consumption 90 W
Maximum RAM consumption on 177 Kbytes
NCU
Slot positions SH9HU: 3...17
SH7HU, SH7HU-R: 3...17
NCU types NCU, NCU-II, NCU-II-P

The following table contains information about all available ports

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 1256: Ports
Optical connector type LC
Fiber type G.652
N-R Network Rx (BWD Raman Laser out)
U-T Upgrade Tx (BWD Raman amplified signal out)
MON-R Upgrade Tx Tap (BWD Raman amplified signal
monitor)
C-T Client Tx (OSC drop)
U-R Upgrade Rx (EDFA input)
N-T Network Tx (EDFA output)
MON-T Network Tx Tap (monitor for EDFA input)
C-R Client Rx (OSC add)

700 Module and System Specification


Chapter 10 Optical Amplifiers

Figure 15: AMP-S20L-C15 Functional Block diagram


T

EDFA Directon C-Band Signal Direction


Fiber Detection Fib Det EDFA
Link Direction
Rx

Fib Det Mon OSC S


R T
FIL Tap FIL
l U N
T R O
C band Signal Direction

OSC Directon

OSC OSC
R PD
Level Set
C T OSC
PD
OSC Directon

C band Signal Direction

Fib Det Mon OSC


FIL FIL
FIL Tap

Fiber Detection Fib Det


Link Direction Tx
BWD Raman
BWD Raman Pump Directon

This table provides the optical specification of the network ports for the BWD
Raman.

Table 1257: Optical Specification N-R to U-T BWD Raman


Passband 1528.5 nm ... 1568.5 nm
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Supported transmission fiber type G.652 (SMF28, Allwave), G.655


(LEAF, TW-RS, Teralight,
TW-Reach), ULL (Ultra-Low
Loss) fiber
Standard gain range for all fiber types. 9 dB to 15 dB2
Extended gain range 9 dB to 18 dB3
Min. data signal total input power at N-R -36 dBm
(without ASE and RAMAN gain)
Max. data signal total input power at N-R 0 dBm at gain = 15 dB,
3 dBm at gain = 12 dB,
6 dBm at gain = 9 dB
Min. OSC input power at N-R -38 dBm
Max. OSC input power at N-R (pump off) -19 dBm
Data signal LOS raise at -38 dBm
clear at -36 dBm
OSC input LOS raise at -39 dBm
clear at -38 dBm
Max total output pump power at N-R 30 dBm1
Gain flatness < 1.5 dBpp
Tilt Setable for: -2.0, -1.5, -1.0 dB
(default = -1.0 dB)
Effective noise figure < -1.0 dB at 15 dB gain
Insertion loss N-R to U-T 2 dB
Optical return loss > 40 dB

Module and System Specification 701


AMP-S20L-C15

Table 1257: Optical Specification N-R to U-T BWD Raman (Continued)


Polarization dependent gain < 0.5 dB
Polarization mode dispersion < 0.5 ps
Latency N-R to U-T < 50 ns
OPR/OPT accuracy +/- 1.0 dB
1. The Amp-S20L-C15 is a Class 1M laser product with hazard level 1M.
According to IEC 60825-2 the maximum allowable power limit is 31.1 dBm
for systems in a wavelength range of 1400 to 1500 nm with automatic power
shutdown and a shutdown time below 0.5 second.
2.The maximum achievable gain may be less than 15 dB, depending on the
fiber type and connector loss.
3. Extended gain range may not meet all standard specs and should only be
used under special circumstances.

This table provides the optical specification for the EDFA directed from upgrade
port (U-R) to network port (N-T).

Table 1258: Optical Specification - U-R to N-T for EDFA


Passband 1528.5 nm ... 1568.5 nm
Max. total input power 7 dBm at gain = 13 dB
10 dBm at gain = 10 dB
13 dBm at gain = 7 dB
16 dBm at gain = 4 dB

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Max. total output power 21 dBm (OPT power limit will attempt
to regulate at 20.8 dBm)
Data signal LOS set -28 dBm
clear -28 dBm
Gain set range 4 dB ... 13 dB
Fixed gain tilt 0 dB
Gain ripple +/-1 dB
Output VOA Level Set Range 0 dB to 12 dB
Output VOA Level Set Accuracy +/-0.5 dB
Noise figure 6.5 dB at gain = 13 dB
7.5 dB at gain = 10 dB
10 dB at gain = 7 dB
13 dB at gain = 4 dB
Optical return loss > 40 dB
Polarization dependent gain < 0.5 dB
Transient Response Transients up to 15 dB per 100 µs
are compressed to <2.5dB with
setting time of <1ms.
Latency U-R to N-T < 250 ns
OPR/OPT accuracy +/- 1 dB

The following table contains the optical specification of the client port.

Table 1259: Optical Specification Client Ports


OSC center wavelength 1528.77 nm
Passband C-T < 250 pm

702 Module and System Specification


Chapter 10 Optical Amplifiers

Table 1259: Optical Specification Client Ports (Continued)


Passband C-R < 250 pm
Insertion loss C-R to N-T 3 dB ... 23 dB (adjustable)
OSC launch power set to -6 dBm ... +2 dBm
Insertion loss N-R to C-T 2 dB
Return loss C-T > 45 dB
Return loss C-R > 45 dB

This table provides the optical specification of the monitoring ports.

Table 1260: Optical Specification Monitoring port


Passband MON-R 1528.5 nm ... 1568.5 nm
MON-R coupling ratio 1% of U-T
Passband MON-T 1528.5 nm ... 1568.5 nm
MON-T coupling ratio 1% of N-T

This table provides information about fault monitoring of the module in general.

Table 1261: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Firmware package mismatch NSA;


Firmware package mismatch SA
Board temperature too high

This table shows information about fault monitoring of the network port.

Table 1262: Fault Monitoring Network Ports


Physical layer Loss of signal (LOS);
Loss of OSC (LOSC);
OSC optical power control high/low;
EDFA amplifier pumps off
EDFA attenuator fail

This table shows information about fault monitoring of the upgrade port.

Table 1263: Fault Monitoring Upgrade Ports


Physical layer BWD amplifier is enabled but shut down. U
port is abnormal and degraded (AMPANR);
Optical power Rx too high/low (OPR);
Loss of signal (LOS);
EDFA amplifier abnormal;
Optical power Tx too high/low (OPT)

Module and System Specification 703


AMP-S20L-C15

This table lists the BWD Raman amplifier faults.

Table 1264: Fault Monitoring - BWD Raman


Amplifier Faults ASE table building;
ASE table not available (NA);
ASE table fail due to pilot;
ASE table fail due to signal;
ASE table fail due to ASE;
FWD ASE pilot ON;
FWD ASE pilot FAIL;
Loss of pilot (Pilot LOS);
Pilot too high;
Gain/tilt not reachable;
Pump laser end-of-life (EOL);
Auto power shutdown;
Auto shutdown due to ASE table;
Auto shutdown due to temperature;
Laser 1/2/3/4 temp too low/high

This table lists the EDFA amplifier faults.

Table 1265: Fault Monitoring - EDFA Amplifier


Amplifier Faults Gain Tilt Abnormal;
End of Life;

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmit Power is Limited;
Auto Shut down due to high pump temperature;
Auto Shut down due to inability to regulate exces-
sive OPT;
Noise reduction APR applied due to LOS;
EDFA Attenuator Fail;

The following table provides information about performance monitoring of the


module in general.

Table 1266: Performance Monitoring - General


Equipment Module temperature (current value);

This table shows information about performance monitoring of the network port.

Table 1267: Performance Monitoring Network Ports


Physical layer OSC optical power Tx (current, low,
(15 min/24 h records available for PM mean, high);
values except current values; EDFA transmit output power current,
low, mean, high)

704 Module and System Specification


Chapter 10 Optical Amplifiers

Table below shows information about performance monitoring of the upgrade


port.

Table 1268: Performance Monitoring Upgrade Ports


Physical layer Optical power Rx (current,
(15 min/24 h records available for PM values low, mean, high, OPR sam-
except current values; pling rate 50 ms to capture
User configurable threshold short events for low, mean,
crossing alerts for OPR/OPT too and high)
high/too low available) Optical power Tx (current,
low, mean, high, OPT sam-
pling rate 50 ms to capture
short events for low, mean,
and high)

This table shows information about performance monitoring of the BWD Raman
amplifier.

Table 1269: Performance Monitoring - BWD Raman


Equipment Laser 1/2/3/4 temperature;
Laser 1/2/3/4 bias current;
Raman pump power;
Operating hours;
Defect seconds (DS)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Back Reflection (current, low, mean, high);


Back Reflection TCA (high, low)

This table shows information about performance monitoring of the EDFA ampli-
fier.

Table 1270: Performance Monitoring - EDFA amplifier


Equipment Laser 1and 2 temperature;
Laser 1 and 2 bias current;
Defect Seconds (DS);
Optical output power (current value);
Gain total; gain current value from combination of
EDFA
EDFA Attenuator current attenuation applied by
VOA

Module and System Specification 705


EDFA-S20H

EDFA-S20H
The EDFA-S20H module is an integrated high gain EDFA designed to operate
over spans supporting 96 C band channels. It is primarily used with the 100G
channel cards that apply electronic dispersion compensation. The amplifier has
an output VOA that allows optimization of the amplifier gain setting and launch
power. The amplifier gain setting is selected to minimize noise while the launch
power is selected to minimize distortions in the fiber. The module contains OSC
filters that remove the need for an additional external OSC filter module there-
fore reducing equipment requirements. The amplifier also has improved gain
and transient control, allowing for better regulation of variations in channel
amplitudes. An optional OSC VOA is available and is used to set the optimal
OSC launch power based on the span loss.
The EDFA-S20H can be used as a booster amplifier, pre-amplifier or in-line
amplifier. Fiber Detection is available on the amplifier U ports.
This table provides general information about the module and its environment.

Table 1271: General Information


Equipment type EDFA-S20
First release 12.2
Width 4 HP
Height 5 HU
Max. weight 725 g (1.59 lbs)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 376,206 h
Typ. power consumption 25 W
Max. power consumption 30 W
Slot positions SH9HU: 3...18
SH1HU: 1 and 2
SH7HU, SH7HU-R: 1...20
NCU types NCU-II, NCU-II-P

This table contains information about all available ports

Table 1272: Ports


Optical connector type LC
Fiber type G.652, G654, G655, LS, DSF
N-R Network Rx (data and OSC signal from network)
U-T Upgrade Tx (data signal output)
MON-R Network Rx Tap (monitoring of incoming data
signal power level at N-R interface)
C-T Client Tx (OSC drop)
U-R Upgrade Rx (EDFA input)
N-T Network Tx (EDFA output)

706 Module and System Specification


Chapter 10 Optical Amplifiers

Table 1272: Ports (Continued)


MON-T Network Tx Tap (monitoring of data signal power
level at N-T interface)
C-R Client Rx (OSC add)

Figure 16: EDFA-S20H Functional Block diagram

MON-T

OS C FI L
U -R N -T
Stage 1 Stage 2

Optojack
Fiber

Mon
Det

UPGRADE NETWORK
OSC VOA

OSC FIL
U -T N -R

MON- R
OSC
C-R C-T 1528 nm
CLIENT

This table provides the optical specification of the network ports for the passive
path from the N-R to U-T ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 1273: Optical Specification N-R to U-T


Passband 1528.5 nm ... 1568.5 nm
Insertion loss N-R to U-T <2 dB

This table provides the optical specification for the EDFA from the U-R to N-T
ports.

Table 1274: Optical Specification - U-R to N-T


Passband 1528.5 nm ... 1568.5 nm
Min. total input power -35 dBm
Max. total input power @ Gain=35 dB: -15 dBm
@ Gain=32 dB: -12 dBm
@ Gain=29 dB: -9 dBm
@ Gain=26 dB: -6 dBm
@ Gain=23 dB: -3 dBm
@ Gain=19 dB: +1 dBm
Max. total output power < 21.3 dBm
Data signal LOS -38 dBm
Gain set range 19dB ... 35dB
Tilt set range -1.5 dB to 0 dB
Gain ripple 1.0 dB peak to peak
Output VOA Level Set Range 0 dB to 12 dB
Output VOA Level Set Accuracy +/-0.5 dB

Module and System Specification 707


EDFA-S20H

Table 1274: Optical Specification - U-R to N-T (Continued)


Noise figure (default tilt) @ Gain = 35 dB: 6.2 dB
@ Gain = 32 dB: 6.2 dB
@ Gain = 29 dB: 6.2 dB
@ Gain = 26 dB: 6.5 dB
@ Gain = 23 dB: 8 dB
@ Gain = 19 dB: 11 dB
Optical return loss > 40 dB
Polarization dependent gain < 0.5 dB
Transient Response Transients up to 15 dB per 100 µs
are compressed to < 3.0dB with
settling time of <1ms.
Latency U-R to N-T 250 ns
OPR/OPT accuracy +/- 0.5 dB

This table contains the optical specification of the client ports.

Table 1275: Optical Specification Client Ports


OSC center wavelength 1528.77 nm
Passband C-T < 250 pm
Passband C-R < 250 pm
Insertion loss C-R to N-T 2 dB if OSC power control is disabled
Set OSC launch power to -6 dBm ... +2 dBm
Insertion loss N-R to C-R 1 dB

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Insertion loss C-T to N-T 1 dB
Return loss C-T > 40 dB
Return loss C-R > 40 dB

This table provides the optical specification of the monitoring ports.

Table 1276: Optical Specification Monitoring ports


Passband MON-R 1528.5 nm ... 1568.5 nm
MON-R coupling ratio 1% of amplifier port output
Passband MON-T 1528.5 nm ... 1568.5 nm
MON-T coupling ratio 1% of amplifier port output

This table provides information about fault monitoring of the module in general.

Table 1277: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA
Board temperature too high

708 Module and System Specification


Chapter 10 Optical Amplifiers

This table shows information about fault monitoring of the network ports.

Table 1278: Fault Monitoring Network Ports


Physical layer Optical power Tx too high/low (OPT)
OSC optical power control high/low;
EDFA amplifier pumps off

This table shows information about fault monitoring of the upgrade ports.

Table 1279: Fault Monitoring Upgrade Ports


Physical layer Optical power Rx too high/low (OPR);
Loss of signal (LOS)

This table lists the EDFA amplifier faults.

Table 1280: Fault Monitoring - EDFA Amplifier


Amplifier Faults Gain Tilt Abnormal;
End of Life;
Transmit Power is Limited;
Auto Shut down due to high pump temperature;
Auto Shut down due to inability to regulate exces-
sive OPT;
Noise reduction APR applied due to LOS;
EDFA Attenuator Fail;
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

This table provides information about performance monitoring of the module in


general.

Table 1281: Performance Monitoring - General


Equipment Module temperature (current value)

This table provides information about performance monitoring of the network


port.

Table 1282: Performance Monitoring Network Ports


Physical layer EDFA transmit output power current,
(15 min/24 h records available for PM low, mean, high)
values except current values;

Module and System Specification 709


EDFA-S20H

This table shows information about performance monitoring of the upgrade


ports.

Table 1283: Performance Monitoring Upgrade Ports


Physical layer Optical power Rx (current,
(15 min/24 h records available for PM values low, mean, high, OPR sam-
except current values; pling rate 50 ms to capture
User configurable threshold short events for low, mean,
crossing alerts for OPR/OPT too and high)
high/too low available) Optical power Tx (current,
low, mean, high, OPT sam-
pling rate 50 ms to capture
short events for low, mean,
and high)

This table shows information about performance monitoring of the EDFA ampli-
fier.

Table 1284: Performance Monitoring - EDFA amplifier


Equipment Laser 1and 2 temperature;
Laser 1 and 2 bias current;
Defect Seconds (DS);
Optical output power (current value);
Gain total; gain current value from combination of

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
EDFA
EDFA Attenuator current attenuation applied by
VOA

710 Module and System Specification


Chapter 10 Optical Amplifiers

EDFA-S20L
The EDFA-S20L module is an integrated low gain EDFA designed to operate
over spans supporting 96 C band channels. It is primarily used with the 100G
channel cards that apply electronic dispersion compensation. The amplifier has
an output VOA that allows optimization of the amplifier gain setting and launch
power. The amplifier gain setting is selected to minimize noise while the launch
power is selected to minimize distortions in the fiber. The module contains OSC
filters that remove the need for an additional external OSC filter module there-
fore reducing equipment requirements. The amplifier also has improved gain
and transient control, allowing for better regulation of variations in channel
amplitudes. An optional OSC VOA is available and is used to set the optimal
OSC launch power based on the span loss.
The EDFA-S20L can be used as a booster amplifier, pre-amplifier or in-line
amplifier. Fiber Detection is available on the amplifier U ports.
This table provides general information about the module and its environment.

Table 1285: General Information


Equipment type EDFA-S20
First release 12.2
Width 4 HP
Height 5 HU
Max. weight 725 g (1.59 lbs)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Environmental conditions Telcordia SR-3580 level 3 (NEBS),


ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 376,206 h
Typ. power consumption 25 W
Max. power consumption 30 W
Slot positions SH9HU: 3...18
SH1HU: 1 and 2
SH7HU, SH7HU-R: 1...20
NCU types NCU-II, NCU-II-P

This table contains information about all available ports

Table 1286: Ports


Optical connector type LC
Fiber type G.652, G654, G655, LS, DSF
N-R Network Rx (data and OSC signal from network)
U-T Upgrade Tx (data signal output)
MON-R Network Rx Tap (monitoring of incoming data
signal power level at N-R interface)
C-T Client Tx (OSC drop)
U-R Upgrade Rx (EDFA input)
N-T Network Tx (EDFA output)

Module and System Specification 711


EDFA-S20L

Table 1286: Ports (Continued)


MON-T Network Tx Tap (monitoring of data signal power
level at N-T interface)
C-R Client Rx (OSC add)

Figure 17: EDFA-S20L Functional Block diagram

MON-T

OS C FI L
U -R N -T
Stage 1 Stage 2

Optojack
Fiber

Mon
Det

UPGRADE NETWORK
OSC VOA

OSC FIL
U -T N -R

MON- R
OSC
C-R C-T 1528 nm
CLIENT

This table provides the optical specification of the network ports for the passive
path from the N-R to U-T ports.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 1287: Optical Specification N-R to U-T
Passband 1528.5 nm ... 1568.5 nm
Insertion loss N-R to U-T < 2 dB

This table provides the optical specification for the EDFA from the U-R to N-T
ports.

Table 1288: Optical Specification - U-R to N-T


Passband 1528.5 nm ... 1568.5 nm
Min. total input power -22 dBm
Max. total input power @ Gain = 21 dB: -1 dBm
@ Gain =18 dB: +2 dBm
@ Gain =15 dB: +5 dBm
@ Gain =11 dB: +9 dBm
Max. total output power < 21.3 dBm
Data signal LOS -24 dBm
Gain set range 11dB ... 21 dB
Tilt set range -1.5 dB to 0 dB
Gain ripple 1.0 dB peak to peak
Output VOA Level Set Range 0 dB to 12 dB
Output VOA Level Set Accuracy +/-0.5 dB

712 Module and System Specification


Chapter 10 Optical Amplifiers

Table 1288: Optical Specification - U-R to N-T (Continued)


Noise figure (default tilt) @ Gain = 21 dB: 5.8 dB
@ Gain = 18 dB: 6.5 dB
@ Gain = 15 dB: 8 dB
@ Gain = 11 dB: 15 dB
Optical return loss > 40 dB
Polarization dependent gain < 0.5 dB
Transient Response Transients up to 15 dB per 100 µs
are compressed to < 3.0dB with
settling time of <1ms.
Latency U-R to N-T 250ns
OPR/OPT accuracy +/- 0.5 dB

This table contains the optical specification of the client ports.

Table 1289: Optical Specification Client Ports


OSC center wavelength 1528.77 nm
Passband C-T < 250 pm
Passband C-R < 250 pm
Insertion loss C-R to N-T 2 dB if OSC power control is disabled
Set OSC launch power to -6 dBm ... +2 dBm
Insertion loss N-R to C-R 1 dB
Insertion loss C-T to N-T 1 dB
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Return loss C-T > 40 dB


Return loss C-R > 40 dB

This table provides the optical specification of the monitoring ports.

Table 1290: Optical Specification Monitoring ports


Passband MON-R 1528.5 nm ... 1568.5 nm
MON-R coupling ratio 1% of amplifier port output
Passband MON-T 1528.5 nm ... 1568.5 nm
MON-T coupling ratio 1% of amplifier port output

This table provides information about fault monitoring of the module in general.

Table 1291: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA
Board temperature too high

Module and System Specification 713


EDFA-S20L

This table shows information about fault monitoring of the network ports.

Table 1292: Fault Monitoring Network Ports


Physical layer Optical power Tx too high/low (OPT)
OSC optical power control high/low;
EDFA amplifier pumps off

This table shows information about fault monitoring of the upgrade ports.

Table 1293: Fault Monitoring Upgrade Ports


Physical layer Optical power Rx too high/low (OPR);
Loss of signal (LOS)

This table lists the EDFA amplifier faults.

Table 1294: Fault Monitoring - EDFA Amplifier


Amplifier Faults Gain Tilt Abnormal;
End of Life;
Transmit Power is Limited;
Auto Shut down due to high pump temperature;
Auto Shut down due to inability to regulate exces-
sive OPT;
Noise reduction APR applied due to LOS;
EDFA Attenuator Fail;

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table provides information about performance monitoring of the module in
general.

Table 1295: Performance Monitoring - General


Equipment Module temperature (current value)

This table provides information about performance monitoring of the network


port.

Table 1296: Performance Monitoring Network Ports


Physical layer EDFA transmit output power current,
(15 min/24 h records available for PM low, mean, high)
values except current values;

714 Module and System Specification


Chapter 10 Optical Amplifiers

This table shows information about performance monitoring of the upgrade


ports.

Table 1297: Performance Monitoring Upgrade Ports


Physical layer Optical power Rx (current,
(15 min/24 h records available for PM values low, mean, high, OPR sam-
except current values; pling rate 50 ms to capture
User configurable threshold short events for low, mean,
crossing alerts for OPR/OPT too and high)
high/too low available) Optical power Tx (current,
low, mean, high, OPT sam-
pling rate 50 ms to capture
short events for low, mean,
and high)

This table shows information about performance monitoring of the EDFA ampli-
fier.

Table 1298: Performance Monitoring - EDFA amplifier


Equipment Laser 1and 2 temperature;
Laser 1 and 2 bias current;
Defect Seconds (DS);
Optical output power (current value);
Gain total; gain current value from combination of
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

EDFA
EDFA Attenuator current attenuation applied by
VOA

Module and System Specification 715


2EDFA-S20L-S10L

2EDFA-S20L-S10L
The 2EDFA-S20L-S10L module is a dual EDFA designed to be an EDFA only
alternative to the EDFA/RAMAN amplifier AMP-S20x in 9ROADM applications
where use of a Raman amplifier is not desired. The amplifier gain and output
power are similar to the AMP-S20x. The 2EDFA-S20L-S10L is primarily used
with the 100G channel cards that apply electronic dispersion compensation.The
amplifier is designed to operate over spans supporting 96 C band channels. The
amplifier has an output VOA that allows optimization of the amplifier gain setting
and launch power. The amplifier gain setting is selected to minimize noise while
the launch power is selected to minimize distortions in the fiber. The module
contains OSC filters that remove the need for an additional external OSC filter
module therefore reducing equipment requirements. The amplifier also has
improved gain and transient control, allowing for better regulation of variations in
channel amplitudes. An OSC VOA is available and is used to set the optimal
OSC launch power based on the span loss.
The 2EDFA-S20L-S10L can be used as a booster amplifier, pre-amplifier or
in-line amplifier. Fiber Detection is available on the amplifier U ports.
This table provides general information about the module and its environment.

Table 1299: General Information


Equipment type 2EDFA-S20L-S10L
First release 12.3

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Width 8 HP
Height 5 HU
Max. weight 1335 g (2.94 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to  IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 275,868 h
Typ. power consumption 25 W
Max. power consumption 50 W
Slot positions SH9HU: 3...17
SH1HU: 1
SH7HU, SH7HU-R: 3...17
NCU types NCU-II, NCU-II-P

This table contains information about all available ports

Table 1300: Ports


Optical connector type LC
Fiber type G.652, G654, G655, LS, DSF
N-R Network Rx (data and OSC signal from network)
U-T Upgrade Tx (data signal output)
MON-R Network Rx Tap (monitoring of incoming data
signal power level at N-R interface)
C-T Client Tx (OSC drop)

716 Module and System Specification


Chapter 10 Optical Amplifiers

Table 1300: Ports (Continued)


U-R Upgrade Rx (EDFA input)
N-T Network Tx (EDFA output)
MON-T Network Tx Tap (monitoring of data signal power
level at N-T interface)
C-R Client Rx (OSC add)

Figure 18: 2EDFA-S20L-S10L Functional Block diagram

2 EDFA-S20L-S10L

C- Band Signals
MON -T

OSC FIL
U-R N-T
Output VOA
Booster Amplifier
Fiber Detection
Link Direction S20 OSC
OSC VOA
1528nm
Fiber
Det

UPGRADE C-R
NETWORK
CLIENT
C- T
Fiber Detection
Link Direction

OSC
1528nm

OSC FIL
U-T N-R
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Pre- Amplifier
S10
MON-R
C- Band Signals

This table provides the optical specification for the EDFA from the N-R to U-T
ports.

Table 1301: Optical Specification N-R to U-T (Pre-Amplifier)


Passband 1528.5 nm ... 1568.5 nm
Min. total input power -28 dBm
Max. total input power @ Gain = 16dB: -6 dBm
@ Gain =13 dB: -3 dBm
@ Gain =10 dB: +0 dBm
@ Gain =7 dB: +3 dBm
Max. total output power < 11 dBm
Data signal LOS -35 dBm
Gain set range 7 dB ... 16 dB
Gain ripple 1.5 dB peak to peak
Noise figure @ Gain = 16 dB: 5.6 dB
@ Gain = 13 dB: 6.2 dB
@ Gain = 10 dB: 7.5 dB
@ Gain = 7 dB: 10.1 dB
Optical return loss > 40 dB
Polarization dependent gain < 0.5 dB

Module and System Specification 717


2EDFA-S20L-S10L

Table 1301: Optical Specification N-R to U-T (Pre-Amplifier)


Transient Response Transients up to 15 dB per 100 µs
are compressed to < 1.0 dB with
settling time of <1ms.
Latency U-R to N-T 250ns
OPR/OPT accuracy +/- 0.5 dB

This table provides the optical specification for the EDFA from the U-R to N-T
ports.

Table 1302: Optical Specification - U-R to N-T (Booster Amplifier)


Passband 1528.5 nm ... 1568.5 nm
Min. total input power -22 dBm
Max. total input power @ Gain = 21 dB: -1 dBm
@ Gain =18 dB: +2 dBm
@ Gain =15 dB: +5 dBm
@ Gain =11 dB: +9 dBm
Max. total output power < 21.3 dBm
Data signal LOS -24 dBm
Gain set range 11dB ... 21 dB
Tilt set range -1.5 dB to 0 dB
Gain ripple 2.0 dB peak to peak
Output VOA Level Set Range 0 dB to 12 dB
Output VOA Level Set Accuracy +/-0.5 dB

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Noise figure (default tilt) @ Gain = 21 dB: 5.8 dB
@ Gain = 18 dB: 6.0 dB
@ Gain = 15 dB: 8 dB
@ Gain = 11 dB: 15 dB
Optical return loss > 40 dB
Polarization dependent gain < 0.5 dB
Transient Response Transients up to 15 dB per 100 µs are
compressed to < 2.5 dB with settling
time of <1ms.
Latency U-R to N-T 250ns
OPR/OPT accuracy +/- 0.5 dB

This table contains the optical specification of the client ports.

Table 1303: Optical Specification Client Ports


OSC center wavelength 1528.77 nm
Passband C-T < 250 pm
Passband C-R < 250 pm
Insertion loss C-R to N-T 2 dB if OSC power control is disabled
Set OSC launch power to -6 dBm ... +2 dBm
Insertion loss N-R to C-R 1 dB
Insertion loss C-T to N-T 1 dB
Return loss C-T > 40 dB
Return loss C-R > 40 dB

718 Module and System Specification


Chapter 10 Optical Amplifiers

This table provides the optical specification of the monitoring ports.

Table 1304: Optical Specification Monitoring ports


Passband MON-R 1528.5 nm ... 1568.5 nm
MON-R coupling ratio 1% of amplifier port output
Passband MON-T 1528.5 nm ... 1568.5 nm
MON-T coupling ratio 1% of amplifier port output

This table provides information about fault monitoring of the module in general.

Table 1305: Fault Monitoring - General


Equipment Module removed;
Module mismatch;
Module voltage abnormal;
General hardware fault;
Firmware package mismatch NSA;
Firmware package mismatch SA;
Board temperature too high

This table shows information about fault monitoring of the network ports.

Table 1306: Fault Monitoring Network Ports


Physical layer Optical power Tx too high/low (OPT);
Optical power Rx too high/low (OPR);
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

OSC optical power control high/low;


EDFA amplifier pumps off;
Loss of Signal (LOS);
Loss of OSC (LOSC)

This table shows information about fault monitoring of the upgrade ports.

Table 1307: Fault Monitoring Upgrade Ports


Physical layer Optical power Tx too high/low (OPT);
Optical power Rx too high/low (OPR);
Loss of signal (LOS);
EDFA amplifier pumps off

This table lists the Booster EDFA faults.

Table 1308: Fault Monitoring - Booster EDFA


Amplifier Faults Gain Tilt Abnormal;
End of Life;
Transmit Power is Limited;
Auto Shut down due to high pump temperature;
Auto Shut down due to inability to regulate exces-
sive OPT;
Noise reduction APR applied due to LOS;
EDFA Attenuator Fail

Module and System Specification 719


2EDFA-S20L-S10L

This table lists the Pre-Amplifier EDFA faults.

Table 1309: Fault Monitoring - Pre-Amplifier EDFA


Amplifier Faults Gain Tilt Abnormal;
End of Life;
Transmit Power is Limited;
Auto Shut down due to high pump temperature;
Noise reduction APR applied due to LOS

This table provides information about performance monitoring of the module in


general.

Table 1310: Performance Monitoring - General


Equipment Module temperature (current value)

This table provides information about performance monitoring of the network


port.

Table 1311: Performance Monitoring Network Ports


Physical layer Optical Receive Power (current, low,
(15 min/24 h records available for PM mean, high);
values except current values; Optical Transmit Power (current, low,
mean, high) OPT sampling rate 50 ms
to capture short events for low, mean,

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
and high);
OSC Power Tx/Rx

This table shows information about performance monitoring of the upgrade


ports.

Table 1312: Performance Monitoring Upgrade Ports


Physical layer Optical power Rx (current,
(15 min/24 h records available for PMvalues low, mean, high;
except current values; OPR sampling rate 50 ms to
User configurable threshold capture short events for low,
crossing alerts for OPR/OPT too mean, and high);
high/too low available) Optical power Tx (current,
low, mean, high;
OPT sampling rate 50 ms to
capture short events for low,
mean, and high)

720 Module and System Specification


Chapter 10 Optical Amplifiers

This table shows information about performance monitoring of the EDFA ampli-
fier.

Table 1313: Performance Monitoring - Booster Amplifier EDFA


Equipment Laser 1 and 2 temperature;
Laser 1 and 2 bias current;
Defect Seconds (DS);
Hours of operation;
Amplifier Power Tx (current value): Output power
current value at the amplifier, before the output
VOA;
Attenuation: Attenuation value of the output VOA.
Should agree with user setting;
Effective Gain: The effective gain from input to
output computed from the current gain of the
amplifier stage and the attenuation setting of the
output VOA.

This table shows information about performance monitoring of the Pre-Amplifier


EDFA.

Table 1314: Performance Monitoring - Pre-Amplifier EDFA


Equipment Laser 1 temperature;
Laser 1 bias current;
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Defect Seconds (DS);


Hours of operation;

This table shows information about performance monitoring for U-port PTP fiber
detection.

Table 1315: Performance Monitoring - PTP Fiber Detection


Equipment OPT
OPR
Fiber connection loss

Module and System Specification 721


722
2EDFA-S20L-S10L

Module and System Specification


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Chapter 11

Dispersion Compensation
Modules
The following chapter describes the dispersion compensation modules of the
FSP 3000R7.
The descriptions of the discontinued dispersion compensation modules can be
found in a former version of the FSP 3000R7 Module and System Specification.
The following sections are provided:
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

“DCF-M/xxx/SSMF” on p. 724
“DCG-M/xxx/SSMF” on p. 727
“DCG50-M/xxx/SSMF” on p. 729
“DCG-M/xxx/TWRS” on p. 731
“DCG50-M/xxx/TWRS” on p. 733
“DCF1HU-P Shelf” on p. 735

Module and System Specification 723


DCF-M/xxx/SSMF

DCF-M/xxx/SSMF
The DCF-M/xxx/SSMF is a managed Dispersion Compensation Module. It can
be used for the compensation of dispersion of Standard Single-Mode Fiber
according to G.652.
The following variants are available:
• DCF-M/010/SSMF
• DCF-M/020/SSMF
• DCF-M/030/SSMF
• DCF-M/040/SSMF
• DCF-M/050/SSMF
• DCF-M/060/SSMF
• DCF-M/070/SSMF
• DCF-M/080/SSMF
• DCF-M/090/SSMF
• DCF-M/100/SSMF

Table 1316: General Information


Equipment type DCF

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
First release 7.1 (010, 020, 040, 060, 080, 100)
9.1 (030, 050, 070, 090)
Width 8 HP
Height 5 HU
Weight 1.2 kg (2.6 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IEC IP20. Use in a pollution degree 2
60529 environment and indoor controlled
office environments only.
Power consumption 1.2 W
Maximum RAM consumption on NCU 25 Kbytes
MTBF at 25°C ambient temperature 54,285,711 h
Slot positions SH9HU: 3...17
SH7HU, SH7HU-R: 3...17
SH1HU: 1
Max. latency
DCF-M/010/SSMF 15 µs
DCF-M/020/SSMF 20 µs
DCF-M/030/SSMF 25 µs
DCF-M/040/SSMF 30 µs
DCF-M/050/SSMF 35 µs
DCF-M/060/SSMF 40 µs
DCF-M/070/SSMF 45 µs
DCF-M/080/SSMF 50 µs
DCF-M/090/SSMF 55 µs
DCF-M/100/SSMF 60 µs

724 Module and System Specification


Chapter 11 Dispersion Compensation Modules

The following table shows the optical connector type.

Table 1317: Interfaces


Optical connector type LC

This table contains information about the optical characteristics.

Table 1318: Optical Characteristics


Operating wavelengths 1529 nm ... 1604 nm
Max. input power 24 dBm
Max. per channel input power 0 dBm
Fiber type SM G.652
Typ. compensation capability
DCF-M/010/SSMF 10 km (393700”)
DCF-M/020/SSMF 20 km (787400”)
DCF-M/030/SSMF 30 km (1181100”)
DCF-M/040/SSMF 40 km (1574800“)
DCF-M/050/SSMF 50 km (1968500”)
DCF-M/060/SSMF 60 km (2362200“)
DCF-M/070/SSMF 70 km (2755900”)
DCF-M/080/SSMF 80 km (3149600“)
DCF-M/090/SSMF 90 km (3543300”)
DCF-M/100/SSMF 100 km (3937000“)
Insertion loss max. value
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

DCF-M/010/SSMF 2.5 dB
DCF-M/020/SSMF 3 dB
DCF-M/030/SSMF 3.6 dB
DCF-M/040/SSMF 4.3 dB
DCF-M/050/SSMF 4.8 dB
DCF-M/060/SSMF 5.4 dB
DCF-M/070/SSMF 6.1 dB
DCF-M/080/SSMF 6.7 dB
DCF-M/090/SSMF 7.3 dB
DCF-M/100/SSMF 8.7 dB
Insertion loss typ. value
DCF-M/010/SSMF 1.65 dB
DCF-M/020/SSMF 2.15 dB
DCF-M/030/SSMF 2.51 dB
DCF-M/040/SSMF 3.2 dB
DCF-M/050/SSMF 3.65 dB
DCF-M/060/SSMF 4.12 dB
DCF-M/070/SSMF 4.74 dB
DCF-M/080/SSMF 5.43 dB
DCF-M/090/SSMF 6.25 dB
DCF-M/100/SSMF 7.1 dB

Module and System Specification 725


DCF-M/xxx/SSMF

Table 1319 provides information about the chromatic dispersion of the modules.
Table 1319: Chromatic Dispersion
CD min CD max CD min CD max CD min CD max
at 1530 nm, in ps/nm at 1562 nm, in ps/nm at 1602 nm, in ps/nm
DCF-M/010/SSMF -168 -152 -187 -173 -210 -191
DCF-M/020/SSMF -336 -304 -373 -347 -419 -381
DCF-M/030/SSMF -479 -456 -547 -520 -608 -572
DCF-M/040/SSMF -672 -608 -746 -693 -838 -762
DCF-M/050/SSMF -799 -760 -911 -867 -1014 -953
DCF-M/060/SSMF -1008 -912 -1118 -1040 -1256 -1143
DCF-M/070/SSMF -1118 -1064 -1275 -1213 -1419 -1334
DCF-M/080/SSMF -1344 -1216 -1492 -1387 -1676 -1524
DCF-M/090/SSMF -1438 -1368 -1640 -1560 -1825 -1715
DCF-M/100/SSMF -1680 -1520 -1864 -1733 -2094 -1905

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

726 Module and System Specification


Chapter 11 Dispersion Compensation Modules

DCG-M/xxx/SSMF
The Fiber-Bragg-Gratings Dispersion Compensation Module (DCG-M) can be
used for dispersion compensation of C-band channels only. It is a managed
module which must not be used on any other fiber type than Standard Single
Mode Fiber according to G.652.
The following variants are available:
• DCG-M/060/SSMF
• DCG-M/080/SSMF
• DCG-M/100/SSMF

Please use the Network Planner tool or contact Network Consultant


for assistance in case of using
PS

• data rates >10 Gbit/s or


Note • more than 4 pieces of DCG modules cascaded in one link.

Table 1320 provides general information about the module and its environment.

Table 1320: General Information


Equipment type DCG
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

First release 7.1


Width 4 HP
Height 5 HU
Weight 550 g (1.2 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection acc. to IEC IP20. Use in a pollution degree 2
60529 environment and indoor controlled
office environments only.
Power consumption 1.2 W
Maximum RAM consumption on NCU 24 Kbytes
MTBF at 25°C ambient temperature 54,285,711 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
Max. latency < 45 ns

The following table contains information about the interfaces.

Table 1321: Interfaces


Optical connector type LC

Module and System Specification 727


DCG-M/xxx/SSMF

This table provides information about the optical characteristics.

Table 1322: Optical Characteristics


Operating frequency range 196.00 THz... 192.00 THz, 
in a 100 GHz channel grid
Max. input power 24 dBm
Typ. compensation capability
DCG-M/060/SSMF 60 km (2362200“)
DCG-M/080/SSMF 80 km (3149600“)
DCG-M/100/SSMF 100 km (3937000“)
Insertion loss max. value 4.5 dB
Insertion loss typical value 2.2 dB
Fiber type SM G.652

Table 1323 provides information about the chromatic dispersion of the modules.

Table 1323: Chromatic Dispersion


CD min CD max CD min CD max
at 195.90 THz at 192.00 THz
DCG-M/060/SSMF -997 -883 -1111 -984
DCG-M/080/SSMF -1329 -1177 -1481 -1312
DCG-M/100/SSMF -1661 -1472 -1851 -1641

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

728 Module and System Specification


Chapter 11 Dispersion Compensation Modules

DCG50-M/xxx/SSMF
The DCG50-M/xxx/SSMF is a Fiber-Bragg-Grating dispersion compensation
module. The module is intended for dispersion compensation of C-band
channels in a 50 GHz channel grid of the FSP 3000R7 DWDM transmission
system.
It is a managed module which must not be used on any other fiber type than
Standard Single Mode Fiber according to G.652.
The following variants are available:
• DCG50-M/020/SSMF
• DCG50-M/040/SSMF
• DCG50-M/060/SSMF
• DCG50-M/080/SSMF
• DCG50-M/100/SSMF

Please use the Network Planner tool or contact Network Consultant


for assistance in case of using
• data rates >10 Gbit/s
• more than 4 pieces of DCG modules cascaded in one link or
PS

• more than one DCG50-M/020/SSMF or one


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Note
DCG50-M/040/SSMF or any combination of one of these DCGs
with DCG50-M/060/SSMF, DCG50-M/080/SSMF or
DCG50-M/100/SSMF in one link.

Table 1324 provides general information about the module and its environment.

Table 1324: General Information


Equipment type DCG
First release 10.1
Width 4 HP
Height 5 HU
Weight 560 g (1.2 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection acc. to IEC IP20. Use in a pollution degree 2
60529 environment and indoor controlled
office environments only.
Power consumption 1.2 W
Maximum RAM consumption on 24 Kbytes
NCU
MTBF at 25°C ambient temperature 54,285,711 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 1...20
SH1HU: 1, 2
Max. latency < 0.05 µs

Module and System Specification 729


DCG50-M/xxx/SSMF

The following table contains information about the interfaces.

Table 1325: Interfaces


Optical connector type LC

This table provides information about the optical characteristics.

Table 1326: Optical Characteristics


Operating frequency range 196.00 THz ... 192.00 THz,
50 GHz spacing in C band acc. to
ITU-T G.694.1
Max. input power 24 dBm
Typ. compensation capability
DCG50-M/020/SSMF 20 km (787400”)
DCG50-M/040/SSMF 40 km (1574800”)
DCG50-M/060/SSMF 60 km (2362200“)
DCG50-M/080/SSMF 80 km (3149600“)
DCG50-M/100/SSMF 100 km (3937000“)
Insertion loss max. value 4.5 dB
Insertion loss typical value 2.2 dB
Fiber type SM G.652

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 1327 provides information about the chromatic dispersion of the modules.

Table 1327: Chromatic Dispersion


CD min CD max CD min CD max
at 195.95 THz at 192.00 THz
DCG50-M/020/SSMF -384 -245 -428 -273
DCG50-M/040/SSMF -703 -551 -784 -615
DCG50-M/060/SSMF -995 -881 -1111 -985
DCG50-M/080/SSMF -1327 -1175 -1482 -1313
DCG50-M/100/SSMF -1658 -1469 -1852 -1641

730 Module and System Specification


Chapter 11 Dispersion Compensation Modules

DCG-M/xxx/TWRS
The Fiber-Bragg-Gratings Dispersion Compensation Module (DCG-M) can be
used for dispersion compensation of C-band channels.
The Fiber Bragg Grating based dispersion compensation module for
TrueWave® RS Fiber is available in three module variants. Each module variant
compensates for a specific amount of dispersion.
The following variants are available:
• DCG-M/160/TWRS
• DCG-M/240/TWRS
• DCG-M/320/TWRS
Please use the Network Planner tool or contact Network Consultant
for assistance in case of using
PS

• data rates >10 Gbit/s or


Note • more than 4 pieces of DCG modules cascaded in one link.

Table 1328 provides general information about the module and its environment.

Table 1328: General Information


Equipment type DCG
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

First release 9.2


Width 4 HP
Height 5 HU
Weight 520 g (1.15 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection acc. to IEC IP20. Use in a pollution degree 2
60529 environment and indoor controlled
office environments only.
Power consumption 1.2 W
Maximum RAM consumption on 24 Kbytes
NCU
MTBF at 25°C ambient temperature 54,285,711 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
Max. latency < 50 ns

The following table contains information about the interfaces.

Table 1329: Interfaces


Optical connector type LC

Module and System Specification 731


DCG-M/xxx/TWRS

This table provides information about the optical characteristics.

Table 1330: Optical Characteristics


Operating frequency range 196.00 THz... 192.00 THz in a 
100 GHz channel grid
Max. input power 24 dBm
Typ. compensation capability
DCG-M/160/TWRS 160 km (6299200“)
DCG-M/240/TWRS 240 km (9448800“)
DCG-M/320/TWRS 320 km (12598400“)
Insertion loss max. value 4.5 dB
Insertion loss typical value 2.2 dB
Number of concatenation in one link 4
Fiber type TrueWave® RS Fiber

Table 1331 provides information about the chromatic dispersion of the modules.

Table 1331: Chromatic Dispersion


CD min CD max CD min CD max
at 195.90 THz at 192.00 THz
DCG-M/160/TWRS -602 -523 -842 -731
DCG-M/240/TWRS -903 -784 -1262 -1096

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
DCG-M/320/TWRS -1204 -1046 -1683 -1462

732 Module and System Specification


Chapter 11 Dispersion Compensation Modules

DCG50-M/xxx/TWRS
The DCG50-M/xxx/TWRS is a Fiber-Bragg-Gratings dispersion compensation
module. The module can be used for dispersion compensation of C-band
channels in a 50 GHz channel grid of the FSP 3000R7 DWDM transmission
system.
The Fiber Bragg Grating based dispersion compensation module for
TrueWave® RS Fiber (according to G.655.C and G.655.D standards) is
available in three module variants. Each module variant compensates for a
specific amount of dispersion.
The following variants are available:
• DCG50-M/160/TWRS
• DCG50-M/240/TWRS
• DCG50-M/320/TWRS
Table 1332 provides general information about the module and its environment.

Table 1332: General Information


Equipment type DCG
First release 10.2
Width 4 HP
Height 5 HU
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Weight 575 g (1.3 lbs)


Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection acc. to IEC IP20. Use in a pollution degree 2
60529 environment and indoor controlled
office environments only.
Power consumption <1W
Maximum RAM consumption on 24 Kbytes
NCU
MTBF at 25°C ambient temperature 54,285,711 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
Max. latency < 50 ns

The following table contains information about the interfaces.

Table 1333: Interfaces


Optical connector type LC

Module and System Specification 733


DCG50-M/xxx/TWRS

This table provides information about the optical characteristics.

Table 1334: Optical Characteristics


Operating frequency range 196.00 THz ... 192.00 THz, 
50 GHz spacing in C band acc. to
ITU-T G.694.1
Max. input power 24 dBm
Typ. compensation capability
DCG50-M/160/TWRS 160 km (6299200“)
DCG50-M/240/TWRS 240 km (9448800“)
DCG50-M/320/TWRS 320 km (12598400“)
Insertion loss max. value 4.8 dB
Insertion loss typical value 3 dB
Fiber type TrueWave® RS Fiber

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

734 Module and System Specification


Chapter 11 Dispersion Compensation Modules

DCF1HU-P Shelf
The DCF1HU-P Shelf is a Dispersion Compensation Shelf with one integrated
module. Chromatic dispersion is compensated for different length of fiber span
regardless of the wavelength (channel number).
The module-integrated DCF1HU-P Shelf is available with a compensation of
Standard Single-Mode Fiber (SSMF; G.652), a compensation of Large Effective
Area Fiber (LEAF; G.655), a compensation of True Wave Reduced Slope Fiber
(TWRS; G.655) and a compensation of MetroCor Fiber (MCOR; G.655).
The DCF1HU-P for dispersion compensation in applications with Standard
Single-Mode Fiber is available in the following variants:
• DCF1HU-P/10/SSMF
• DCF1HU-P/20/SSMF
• DCF1HU-P/40/SSMF
• DCF1HU-P/60/SSMF
• DCF1HU-P/80/SSMF
• DCF1HU-P/100/SSMF
• DCF1HU-P/120/SSMF
• DCF1HU-P/140/SSMF
• DCF1HU-P/160/SSMF
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

• DCF1HU-P/180/SSMF
The DCF1HU-P for dispersion compensation in applications with Large
Effective Area Fiber is available in the following variants:
• DCF1HU-P/20/LEAF
• DCF1HU-P/40/LEAF
• DCF1HU-P/60/LEAF
• DCF1HU-P/80/LEAF
• DCF1HU-P/100/LEAF
• DCF1HU-P/120/LEAF
• DCF1HU-P/140/LEAF
• DCF1HU-P/160/LEAF
• DCF1HU-P/180/LEAF
The DCF1HU-P for dispersion compensation in applications with True Wave
Reduced Slope Fiber is available in the following variants:
• DCF1HU-P/20/TWRS
• DCF1HU-P/40/TWRS
• DCF1HU-P/80/TWRS
• DCF1HU-P/100/TWRS
• DCF1HU-P/120/TWRS

Module and System Specification 735


DCF1HU-P Shelf

• DCF1HU-P/140/TWRS
• DCF1HU-P/160/TWRS
• DCF1HU-P/180/TWRS
The DCF1HU-P for dispersion compensation in applications with MetroCor
Fiber is available in the following variants:
• DCF1HU-P/010/MCOR
• DCF1HU-P/020/MCOR
• DCF1HU-P/030/MCOR
• DCF1HU-P/040/MCOR
• DCF1HU-P/050/MCOR
• DCF1HU-P/060/MCOR
Table 1335 provides general information about the module and its environment.

Table 1335: General Information


First release DCF1HU-P/x/SSMF 7.1
First release DCF1HU-P/x/LEAF 7.1.5
First release DCF1HU-P/x/TWRS 7.1.5
First release DCF1HU-P/x/MCOR 11.1
Width (dimension without adaptor 442 mm (17.40”)
brackets)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Height 44 mm (1.73”)
Depth (dimension without adaptor 267 mm (10.51”)
brackets)
Max. weight DCF1HU-P/x/SSMF 6.65 kg (14.7 lbs)
Max. weight DCF1HU-P/x/LEAF 4.07 kg (9 lbs)
Max. weight DCF1HU-P/x/TWRS 4.07 kg (9 lbs)
Max. weight DCF1HU-P/x/MCOR 4.7 kg (10.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection acc. to IEC 60529 IP20. Use in a pollution degree 2
environment and indoor controlled
office environments only.
Power consumption n.a.
MTBF at 25°C ambient temperature
DCF1HU-P/x/SSMF 71,428,574 h
DCF1HU-P/x/LEAF 71,428,574 h
DCF1HU-P/x/TWRS 71,428,574 h
DCF1HU-P/x/MCOR 212,765,957 h

736 Module and System Specification


Chapter 11 Dispersion Compensation Modules

Table 1335: General Information (Continued)


Max. latency DCF1HU-P/x/SSMF
DCF1HU-P/10/SSMF 12.5 µs
DCF1HU-P/20/SSMF 25 µs
DCF1HU-P/40/SSMF 50 µs
DCF1HU-P/60/SSMF 75 µs
DCF1HU-P/80/SSMF 100 µs
DCF1HU-P/100/SSMF 125 µs
DCF1HU-P/120/SSMF 150 µs
DCF1HU-P/140/SSMF 175 µs
DCF1HU-P/160/SSMF 200 µs
DCF1HU-P/180/SSMF 225 µs
Max. latency DCF1HU-P/x/LEAF
DCF1HU-P/20/LEAF 25 µs
DCF1HU-P/40/LEAF 50 µs
DCF1HU-P/60/LEAF 75 µs
DCF1HU-P/80/LEAF 100 µs
DCF1HU-P/100/LEAF 125 µs
DCF1HU-P/120/LEAF 150 µs
DCF1HU-P/140/LEAF 175 µs
DCF1HU-P/160/LEAF 200 µs
DCF1HU-P/180/LEAF 225 µs
Max. latency DCF1HU-P/x/TWRS
DCF1HU-P/20/TWRS 25 µs
DCF1HU-P/40/TWRS 50 µs
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

DCF1HU-P/60/TWRS 75 µs
DCF1HU-P/80/TWRS 100 µs
DCF1HU-P/100/TWRS 125 µs
DCF1HU-P/120/TWRS 150 µs
DCF1HU-P/140/TWRS 175 µs
DCF1HU-P/160/TWRS 200 µs
DCF1HU-P/180/TWRS 225 µs
Max. latency DCF1HU-P/x/MCOR
DCF1HU-P/010/MCOR 20 µs
DCF1HU-P/020/MCOR 40 µs
DCF1HU-P/030/MCOR 60 µs
DCF1HU-P/040/MCOR 80 µs
DCF1HU-P/050/MCOR 100 µs
DCF1HU-P/060/MCOR 120 µs

The following table contains information about the optical connector type.

Table 1336: Interfaces


Optical connector type LC

Module and System Specification 737


DCF1HU-P Shelf

The following table provides information about the optical characteristics.

Table 1337: Optical Characteristics


Operating wavelengths 1529 nm ... 1562 nm
Max. input power 24 dBm
Max. per channel input power 0 dBm
Standard Single-Mode Fibers (G.652) Min. compensation Insertion loss
capability for SSMF max. value
DCF1HU-P/10/SSMF 10 km (393700”) 2.2 dB
DCF1HU-P/20/SSMF 20 km (787400”) 2.7 dB
DCF1HU-P/40/SSMF 40 km (1574800“) 3.7 dB
DCF1HU-P/60/SSMF 60 km (2362200“) 4.8 dB
DCF1HU-P/80/SSMF 80 km (3149600“) 5.8 dB
DCF1HU-P/100/SSMF 100 km (3937000“) 6.9 dB
DCF1HU-P/120/SSMF 120 km (4724400“) 7.9 dB
DCF1HU-P/140/SSMF 140 km (5511800“) 9 dB
DCF1HU-P/160/SSMF 160 km (6299200“) 10 dB
DCF1HU-P/180/SSMF 180 km (7086600“) 11.1 dB
Large Effective Area Fibers (LEAF) Min. compensation Insertion loss
for LEAF max. value
DCF1HU-P/20/LEAF 20 km (787400”) 3.1 dB
DCF1HU-P/40/LEAF 40 km (1574800“) 4.8 dB
DCF1HU-P/60/LEAF 60 km (2362200“) 6.3 dB
DCF1HU-P/80/LEAF 80 km (3149600“) 7.5 dB

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
DCF1HU-P/100/LEAF 100 km (3937000“) 8.8 dB
DCF1HU-P/120/LEAF 120 km (4724400“) 9.4 dB
DCF1HU-P/140/LEAF 140 km (5511800“) 10 dB
DCF1HU-P/160/LEAF 160 km (6299200“) 11 dB
DCF1HU-P/180/LEAF 180 km (7086600“) 12 dB
True Wave Reduced Slope Fibers Min. compensation Insertion loss
(TWRS) for TWRS max. value
DCF1HU-P/20/TWRS 20 km (787400”) 3.2 dB
DCF1HU-P/40/TWRS 40 km (1574800“) 3.7 dB
DCF1HU-P/60/TWRS 60 km (2362205”) 4.2 dB
DCF1HU-P/80/TWRS 80 km (3149600“) 4.8 dB
DCF1HU-P/100/TWRS 100 km (3937000“) 5.3 dB
DCF1HU-P/120/TWRS 120 km (4724400“) 5.9 dB
DCF1HU-P/140/TWRS 140 km (5511800“) 6.4 dB
DCF1HU-P/160/TWRS 160 km (6299200“) 6.9 dB
DCF1HU-P/180/TWRS 180 km (7086600“) 7.4 dB
MetroCor Fiber (MCOR) Min. compensation Insertion loss
for (MCOR) max. value
DCF1HU-P/010/MCOR 10 km (393700“) 2.3 dB
DCF1HU-P/020/MCOR 20 km (787400“) 3.0 dB
DCF1HU-P/030/MCOR 30 km (1181100“) 3.8 dB
DCF1HU-P/040/MCOR 40 km (1574800“) 4.5 dB
DCF1HU-P/050/MCOR 50 km (1968500“) 5.3 dB
DCF1HU-P/060/MCOR 60 km (2362200“) 6.1 dB

738 Module and System Specification


Chapter 11 Dispersion Compensation Modules

Table 1338 provides information about the chromatic dispersion for the
DCF1HU-P shelf variants with Standard Single-Mode Fiber (SSMF), Large
Effective Area Fiber (LEAF), and True Wave Reduced Slope Fiber (TWRS).

Table 1338: Chromatic Dispersion (CD) for the Shelves with SSMF, LEAF and
TWRS Fibers
CD at 1529nm CD at 1561 nm
[ps/nm] [ps/nm]
Minimum Maximum Minimum Maximum
DCF1HU-P/10/SSMF -162 -151 -182 -170
DCF1HU-P/20/SSMF -324 -301 -364 -341
DCF1HU-P/40/SSMF -647 -604 -728 -682
DCF1HU-P/60/SSMF -971 -906 -1091 -1023
DCF1HU-P/80/SSMF -1294 -1209 -1455 -1365
DCF1HU-P/100/SSMF -1616 -1509 -1815 -1705
DCF1HU-P/120/SSMF -1940 -1811 -2179 -2047
DCF1HU-P/140/SSMF -2263 -2113 -2542 -2388
DCF1HU-P/160/SSMF -2586 -2415 -2905 -2730
DCF1HU-P/180/SSMF -2909 -2717 -3268 -3070

DCF1HU-P/20/LEAF -57 -41 -111 -94


DCF1HU-P/40/LEAF -113 -82 -222 -189
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

DCF1HU-P/60/LEAF -169 -123 -332 -283


DCF1HU-P/80/LEAF -226 -165 -443 -378
DCF1HU-P/100/LEAF -282 -206 -553 -472
DCF1HU-P/120/LEAF -338 -247 -664 -567
DCF1HU-P/140/LEAF -394 -289 -775 -661
DCF1HU-P/160/LEAF -451 -330 -885 -756
DCF1HU-P/180/LEAF -507 -371 -996 -850

DCF1HU-P/20/TWRS -78 -68 -105 -94


DCF1HU-P/40/TWRS -155 -136 -209 -188
DCF1HU-P/60/TWRS -233 -204 -313 -282
DCF1HU-P/80/TWRS -310 -272 -417 -377
DCF1HU-P/100/TWRS -388 -340 -521 -471
DCF1HU-P/120/TWRS -465 -409 -625 -565
DCF1HU-P/140/TWRS -543 -477 -729 -660
DCF1HU-P/160/TWRS -620 -545 -833 -754
DCF1HU-P/180/TWRS -698 -613 -937 -848

Module and System Specification 739


DCF1HU-P Shelf

Table 1339 provides information about the chromatic dispersion for the
DCF1HU-P shelf variants with MetroCor Fiber (MCOR).

Table 1339: Chromatic Dispersion (CD) for the Shelves with MCOR Fiber
CD at 1530 nm CD at 1562 nm
[ps/nm] [ps/nm]
Minimum Maximum Minimum Maximum
DCF1HU-P/010/MCOR 53 59 60 67
DCF1HU-P/020/MCOR 107 118 121 134
DCF1HU-P/030/MCOR 162 176 183 199
DCF1HU-P/040/MCOR 216 235 244 266
DCF1HU-P/050/MCOR 270 293 305 332
DCF1HU-P/060/MCOR 325 352 368 397

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

740 Module and System Specification


Appendix A

Overview of Modules
This document contains tables with general information about channel modules
as well as their relationships to each other as an overview. An overview of
pluggable transceivers is also provided.
This chapter is divided up into the following sections:
“Client and Network Interfaces” on p. 743
“DWDM Modules - Channel Grid Support” on p. 746
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

“Pluggable Interfaces - Channel Grid Support” on p. 747


“Optical Amplifiers - Channel Grid Support” on p. 747
“ROADM Supported Channel Modules and Amplifiers” on p. 748
“ROADM Compatible Pluggable Transceivers” on p. 752
“Loop Functionality Support” on p. 753
“Channel Module Protection Capabilities” on p. 755
“Channel Module Regeneration Capabilities” on p. 758
“Data Rates and Services” on p. 761
This section is divided up into the following subsections:
“Channel Module Services” on p. 763
“Channel Module Data Rates” on p. 767
“Channel Module In-band Management Support” on p. 771
“Channel Module Error Signaling on Client Port” on p. 774
“Pluggable Interfaces” on p. 775
This section is divided up into the following subsections:
“XFP/SFP/CFP Gray Interfaces” on p. 775
“XFP/SFP/CFP Colored Interfaces” on p. 779

Module and System Specification 741


“Assignment of Pluggable Transceivers” on p. 781
This section is divided up into the following subsections:
“XFPs at the Client Ports” on p. 781
“XFPs at the Network Ports” on p. 782
“SFPs at the Client Ports” on p. 783
“SFPs at the Network Ports” on p. 786
“CFPs at the Client Ports” on p. 787

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

742 Module and System Specification


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Client and Network Interfaces


Module and System Specification

Network Port Type


No. Network Ports
Client Port Type

Opt. dispersion
No.Client Ports
Output

Release No.

load [ps/nm]
Output
Power Sensitivity Sensitivity
Power
Client Client Port Network
Network
Port [dBm] Port [dBm]
Port [dBm]
[dBm]

WCC-PCTN-100GA -5.0 to -50000 to


11.1 1 CFP - - 1 Tun -18.0 to -2.0
+1.0 +50000
WCC-PCTN-100GB -5.0 to -6000 to
12.1 1 CFP - - 1 Tun -18.0 to -2.0
+1.0 +60000
WCC-PCTN-10G-LN#DC -300 to
8.2 1 XFP - - 1 Tun -3.0 to 0.0 -16.0 to -1.0
300
WCC-PCTN-10G-V#DC 8.3 1 XFP - - 1 Tun 4.0 to 6.0 -20.0 to -8.0 200 to 900
WCC-PCTN-10G-V#DL 9.3 1 XFP - - 1 Tun 3.0 to 5.0 -20.0 to -8.0 200 to 900
4TCC-PCTN-2G7+10G-LN#DC -300 to
8.2 4 SFP - - 1 Tun -3.0 to 0.0 -16.0 to -1.0
300
4TCC-PCTN-2G7+10G-V#DC 8.3 4 SFP - - 1 Tun 4.0 to 6.0 -20.0 to -8.0 200 to 900
4TCC-PCTN-2G7+10G-V#DL 8.3 4 SFP - - 1 Tun 3.0 to 5.0 -20.0 to -8.0 200 to 900
10TCC-PCTN-4GUS+10G-LN#DC -300 to
9.3 10 SFP - - 1 Tun -3.0 to 0.0 -16.0 to -1.0
300
10TCC-PCTN-4GUS+10G-V#DC 9.3 10 SFP - - 1 Tun 4.0 to 6.0 -20.0 to -8.0 200 to 900
10TCC-PCTN-4GUS+10G-V#DL 9.3 10 SFP - - 1 Tun 3.0 to 5.0 -20.0 to -8.0 200 to 900

Appendix A Overview of Modules


10TCC-PCN-2G7US+10G 11.1 10 SFP - - 2 XFP - - -
10TCC-PCTN-10G+100GB -5.0 to -6000 to
12.1 10 SFP+ - - 1 Tun -18.0 to -2.0
+1.0 +60000
10WXC-PCN-10G 12.1 - XFP - - - XFP - - -
2WCC-PCN-10G 10.2 2 XFP - - 2 XFP - - -
2TWCC-PCN-2G7U 8.3 2 SFP - - 2 SFP - - -
WCC-PC1N-2G7U 7.1 1 SFP - - 1 SFP - - -
2PCA-PCN-10G 10.1 2 XFP - - 2 XFP - - -
10PCA-PCN-1G3+10G 9.1 2 SFP - - 2 XFP - - -
2WCA-PCN-10G 9.1 2 XFP - - 2 XFP - - -
743
744

Network Port Type


No. Network Ports
Client Port Type
No.Client Ports

Opt. dispersion
Output

Release No.

load [ps/nm]
Output
Power Sensitivity Sensitivity
Power
Client Client Port Network
Network
Port [dBm] Port [dBm]
Port [dBm]
[dBm]

8TCA-PC-2G1U+10G-V#Dxx 7.05 8 SFP - - 1 Fix 5.0 to 7.0 -23.0 to -8.0 800


8TCA-PC-2G1U+10G-V#Cxxxx 7.05 8 SFP - - 1 Fix 5.0 to 7.0 -23.0 to -8.0 800
4TCA-PCN-4GU+4G 8.1 4 SFP - - 2 SFP - - -
4TCA-PCN-4GUS+4G 9.3 4 SFP - - 2 SFP - - -
WCA-PCN-2G5U 7.01 1 SFP - - 2 SFP - - -
WCE-PCN-100G 11.2 1 CFP - - 1 CFP - - -
WCE-PCN-100GB 12.3 1 CFP - - 1 CFP - - -
4WCE-PCN-16GFC 11.2 4 SFP+ - - 4 XFP - - -
5TCE-PCTN-10GU+10G-LN#DC -300 to
9.3 5 SFP - - 1 Tun -3.0 to 0.0 -14.0 to -1.0
300
5TCE-PCTN-10GU+10G-V#DC 9.3 5 SFP - - 1 Tun 4.0 to 6.0 -20.0 to -8.0 200 to 800
5TCE-PCTN-10GU+10G-V#DL 9.3 5 SFP - - 1 Tun 3.0 to 5.0 -20.0 to -8.0 200 to 800
5TCE-PCTN-10GU+AES10G-LN#DC -300 to
10.3 5 SFP - - 1 Tun -3.0 to 0.0 -14.0 to -1.0
300
5TCE-PCTN-10GU+AES10G-V#DC 10.3 5 SFP - - 1 Tun 4.0 to 6.0 -20.0 to -8.0 200 to 800
5TCE-PCTN-10GU+AES10G-V#DL 10.3 5 SFP - - 1 Tun 3.0 to 5.0 -20.0 to -8.0 200 to 800
5TCE-PCTN-8GU+10GS-LN#DC -300 to
11.1 5 SFP - - 1 Tun -3.0 to 0.0 -14.0 to -1.0
300
Module and System Specification

5TCE-PCTN-8GU+10GS-V#DC 11.1 5 SFP - - 1 Tun 4.0 to 6.0 -20.0 to -8.0 200 to 800
5TCE-PCTN-8GU+AES10GS-LN#DC -300 to
11.1 5 SFP - - 1 Tun -3.0 to 0.0 -14.0 to -1.0
300
5TCE-PCTN-8GU+AES10GS-V#DC 11.1 5 SFP - - 1 Tun 4.0 to 6.0 -20.0 to -8.0 200 to 800
5TCE-PCN-10GU+10G SFP/
12.3 5 - - 1 SFP+ - - -
SFP+
5TCE-PCN-10GU+AES10G SFP/
12.3 5 - - 1 SFP+ - - -
SFP+
10TCE-PCN-16GU+AES100G 12.3 10 SFP+ - - 1 CFP - - -

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification

Network Port Type


No. Network Ports
Client Port Type
No.Client Ports

Opt. dispersion
Output

Release No.

load [ps/nm]
Output
Power Sensitivity Sensitivity
Power
Client Client Port Network
Network
Port [dBm] Port [dBm]
Port [dBm]
[dBm]

10TCE-PCN-10G+100G 11.2 10 SFP+ - - 1 CFP - - -


10TCE-PCN-10G+100G-GF 11.2 10 SFP+ - 1 CFP - - -

Appendix A Overview of Modules


745
DWDM Modules - Channel Grid Support
50 GHz 50 GHz grid
ALS ALS switch
grid odd channel
support off supported
stability support
WCC-PCTN-100GA yes yes n.a. n.a.
WCC-PCTN-100GB yes yes n.a. n.a
WCC-PCTN-10G-LN#DC yes yes yes yes
WCC-PCTN-10G-V#DC yes yes yes yes
WCC-PCTN-10G-V#DL no no yes no
4TCC-PCTN-2G7+10G-LN#DC yes yes yes yes
4TCC-PCTN-2G7+10G-V#DC yes yes yes yes
4TCC-PCTN-2G7+10G-V#DL no no yes no
10TCC-PCTN-4GUS+10G-LN#DC yes yes yes yes
10TCC-PCTN-4GUS+10G-V#DC yes yes yes yes
10TCC-PCTN-4GUS+10G-V#DL no no yes no
10TCC-PCN-2G7US+10G XFP XFP no n.a.
10TCC-PCTN-10G+100GB yes yes n.a. n.a.
10WXC-PCN-10G XFP XFP no n.a.
2WCC-PCN-10G XFP XFP no n.a.
2TWCC-PCN-2G7U SFP SFP yes yes1
WCC-PC1N-2G7U SFP SFP yes yes1
2PCA-PCN-10G XFP XFP no n.a.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
10PCA-PCN-1G3+10G XFP XFP no n.a.
2WCA-PCN-10G XFP XFP no n.a.
4TCA-PCN-4GU+4G SFP SFP yes yes1
4TCA-PCN-4GUS+4G SFP SFP yes yes1
WCA-PCN-2G5U SFP SFP yes yes1, 2
WCE-PCN-100G CFP CFP no n.a.
WCE-PCN-100GB CFP CFP no n.a.
4WCE-PCN-16GFC XFP XFP no n.a.
5TCE-PCTN-10GU+10G-LN#DC yes yes no n.a.
5TCE-PCTN-10GU+10G-V#DC yes yes no n.a.
5TCE-PCTN-10GU+10G-V#DL no no no n.a.
5TCE-PCTN-10GU+AES10G-LN#DC yes yes no n.a.
5TCE-PCTN-10GU+AES10G-V#DC yes yes no n.a.
5TCE-PCTN-10GU+AES10G-V#DL no no no n.a.
5TCE-PCN-10GU+10G SFP+ SFP+ no n.a.
5TCE-PCN-10GU+AES10G SFP+ SFP+ no n.a.
5TCE-PCTN-8GU+10GS-LN#DC yes yes no n.a.
5TCE-PCTN-8GU+10GS-V#DC yes yes no n.a.
5TCE-PCTN-8GU+AES10GS-LN#DC yes yes no n.a.
5TCE-PCTN-8GU+AES10GS-V#DC yes yes no n.a.
10TCE-PCN-16GU+AES100G CFP CFP no n.a.
10TCE-PCN-10G+100G CFP CFP no n.a.
10TCE-PCN-10G+100G-GF CFP CFP no n.a.
1. except L band
2. Requires FWP-Version 8.16.0 or later and capability level 1.

746 Module and System Specification


Appendix A Overview of Modules

Pluggable Interfaces - Channel Grid Support

50 GHz grid 50 GHz grid odd


stability channel support
XFP/16GFC/#xxxxxL/SM/LC#Dxx no no
XFP/16GFC/#19xxxL50/SM/LC yes yes
XFP/11G/DCTV/SM/LC yes yes
XFP/11G/DCTLNR/SM/LC yes yes
XFP/11G/DCTLN/SM/LC yes yes
XFP/11G/Dxxxx.xxV/SM/LC#Dxx no no
XFP/OTN11G/#19xxxV/SM/LC no no
XFP/11G/#19xxxL50/SM/LC yes yes
XFP/8G/#xxxxxL/SM/LC#Dxx no no
SFP+/11GU/#19xxxL50/SM/LC yes yes
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx no no
SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx no no
SFP/3GSDI/#xxxxxV/SM/LC no no
SFP/FE/Dxxxxx.xxV/SM/LC yes no
CFP/4x28G/#19xxx-#19xxxL/SM/LC yes yes
CFP/4x28G/#DCTL/SM/LC yes yes
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Optical Amplifiers - Channel Grid Support


50 GHz support
EDFA-C-S20-GCB-DM yes
EDFA-C-D20-VGC-DM yes
EDFA-C-D20-VLGC-DM yes
EDFA-C-S26-VGC-DM yes
EDFA-C-D17-GC yes
EDFA-L-D17-GC no
RAMAN-C10 yes
2RAMAN-C15-LL yes
AMP-S20L-C15 yes
AMP-S20H-C15 yes
EDFA-S20H yes
EDFA-S20L yes
2EDFA-S20L-S10L yes

Module and System Specification 747


ROADM Supported Channel Modules and Amplifiers
748

ROADM-C80/0/OPM 8ROADM- 8ROADM- 9ROADM-C96/ 4ROADM-C96/0/OPM


100 GHz 50 GHz C40/0/OPM C80/0/OPM 0/OPM 100 GHz 50 GHz
WCC-PCTN-100GA X X X X X X X
WCC-PCTN-100GB X X X X X X X
WCC-PCTN-10G-LN#DC X X X X - X X
4TCC-PCTN-2G7+10G-LN#DC X X X X - X X
10TCC-PCTN-4GUS+10G-LN#DC X X X X - X X
10TCC-PCN-2G7US+10G X X1 X X1 - X1 X1
10TCC-PCTN-10G+100GB X X X X X X X
10WXC-PCN-10G X X1 X X1 - X1 X1
2WCC-PCN-10G X X 1 X X 1 - X 1
X1
2TWCC-PCN-2G7U X - X X1 - X1 X1
WCC-PC1N-2G7U X - X X1 - X1 X1
2PCA-PCN-10G X X1 X X1 - X1 X1
10PCA-PCN-1G3+10G X X1 X X1 - X1 X1
2WCA-PCN-10G X2 X1,2 X2 X1,2 - X1,2 X1,2
4TCA-PCN-4GU+4G X - X - - X -
4TCA-PCN-4GUS+4G X - X - - X -
WCA-PCN-2G5U X2,3 - X2,3 - - X2,3 -
WCE-PCN-100G X X X X - X X
Module and System Specification

WCE-PCN-100GB X X X X - X X
4WCE-PCN-16GFC X2 X1,2 X2 X1,2 - X1,2 X1,2
5TCE-PCTN-10GU-LN#DC X X X X - X X
5TCE-PCTN-10GU+AES10G-LN#DC X X X X - X X
5TCE-PCN-10GU+10G X X1 X X1 - X X1
5TCE-PCN-10GU+AES10G X X1 X X1 - X X1
5TCE-PCTN-8GU+10GS-LN#DC X X X X - X X
5TCE-PCTN-8GU+AES10GS-LN#DC X X X X - X X
10TCE-PCN-10G+100G(-GF) X X X X - X X

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification

ROADM-C80/0/OPM 8ROADM- 8ROADM- 9ROADM-C96/ 4ROADM-C96/0/OPM


100 GHz 50 GHz C40/0/OPM C80/0/OPM 0/OPM 100 GHz 50 GHz
10TCE-PCN-16GU+AES100G X X X X - X X
EDFA-C-D17-GC X X X X - - -
EDFA-C-D20-VGC-DM X X X X - X4 X4
EDFA-C-D20-VLGC-DM X X X X - X4 X4
EDFA-C-S20-GCB-DM X X X X - X4 X4
EDFA-C-S26-VGC(B)-DM X X X X - X4 X4
RAMAN-C10 X X X X - X4 X4
2RAMAN-C15-LL - - - - - - -
AMP-S20L-C15 - - - - X - -
AMP-S20H-C15 - - - - X - -
EDFA-S20H - - - - X - -
EDFA-S20L - - - - X - -
2EDFA-S20L-S10L - - - - X - -
1. Depends on the network pluggable transceiver.
2. Requires client signal presence for initial turn-up and may require user initiated equalization along the channel path after power outage.
3. Not supported when capability = LEVEL0.
4. Only channels between #19200 and #19595 can be used

Appendix A Overview of Modules


749
CCM Supported Channel Modules and
Amplifiers
CCM-C40/8 CCM-C80/8 CCM-C96/9
WCC-PCTN-100GA X X -
WCC-PCTN-100GB X X X
WCC-PCTN-10G-LN#DC X X -
4TCC-PCTN-2G7+10G-LN#DC X X -
10TCC-PCTN-4GUS+10G-LN#DC X X -
10TCC-PCN-2G7US+10G X X1 -
10TCC-PCTN-10G+100GB X X X
10WXC-PCN-10G X X 1 -
2WCC-PCN-10G X X 1 -
2TWCC-PCN-2G7U X X1 -
WCC-PC1N-2G7U X X1 -
2PCA-PCN-10G X X1 -
10PCA-PCN-1G3+10G X X 1 -
2WCA-PCN-10G X2
X 2 -
4TCA-PCN-4GU+4G X - -

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
4TCA-PCN-4GUS+4G X - -
WCA-PCN-2G5U X2, 3 - -
WCE-PCN-100G - X -
WCE-PCN-100GB - X -
4WCE-PCN-16GFC X2 X2 -
5TCE-PCTN-10GU-LN#DC X X -
5TCE-PCTN-10GU+AES10G-LN#DC X X -
5TCE-PCTN-8GU+10GS-LN#DC X X -
5TCE-PCTN-8GU+AES10GS-LN#DC X X -
5TCE-PCN-10GU+10G X X1 -
5TCE-PCN-10GU+AES10G X X1 -
10TCE-PCN-10G+100G(-GF) X X -
10TCE-PCN-16GU+AES100G X X -
EDFA-C-D17-GC X X -
EDFA-C-D20-VGC-DM X X -
EDFA-C-D20-VLGC-DM X X -
EDFA-C-S20-GCB-DM X X -
EDFA-C-S26-VGC(B)-DM - - -
RAMAN-C10 - - -
2RAMAN-C15-LL - - -
AMP-S20L-C15 - - -
AMP-S20H-C15 - - -

750 Module and System Specification


Appendix A Overview of Modules

CCM-C40/8 CCM-C80/8 CCM-C96/9


EDFA-S20H - - -
EDFA-S20L - - -
2EDFA-S20L-S10L - - -
1. Depends on the network pluggable transceiver.
2. Requires client signal presence for initial turn-up and may require user initiated equalization along
the channel path after power outage.
3. Not supported when capability = LEVEL0.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 751


ROADM Compatible Pluggable Transceivers
752

ROADM-
8ROADM- 8ROADM- 9ROADM- 4ROADM-C96/0/OPM
C80/0/OPM
C40/0/OPM C80/0/OPM C96/0/OPM
100 GHz 50 GHz 100 GHz 50 GHz
XFP/16GFC/#xxxxxL/SM/LC#Dxx X - X - - X -
XFP/16GFC/#19xxxL50/SM/LC X X X X - X X
XFP/11G/DCTV/SM/LC X X X X - X X
XFP/11G/DCTLNR/SM/LC X X X X - X X
XFP/11G/DCTLN/SM/LC X X X X - X X
XFP/11G/Dxxxx.xxV/SM/LC#Dxx X - X - - X -
XFP/OTN11G/#19xxxV/SM/LC X - X - - X -
XFP/11G/#19xxxL50/SM/LC X X X X - X X
XFP/8G/#xxxxxL/SM/LC#Dxx X - X - - X -
SFP+/11GU/#19xxxL50/SM/LC X X X X - X X
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx X - X - - X -
SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx X - X - - X -
SFP/3GSDI/#xxxxxV/SM/LC X - X - - X -
CFP/4x28G/#19xxx-#19xxxL/SM/LC X X X X - X X
CFP/4x28G/#DCTL/SM/LC X X X X - X X
Module and System Specification

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Appendix A Overview of Modules

CCM Compatible Pluggable Transceivers

CCM-C40/8 CCM-C80/8
XFP/16GFC/#xxxxxL/SM/LC#Dxx X -
XFP/16GFC/#19xxxL50/SM/LC X X
XFP/11G/DCTV/SM/LC X X
XFP/11G/DCTLNR/SM/LC X X
XFP/11G/DCTLN/SM/LC X X
XFP/11G/Dxxxx.xxV/SM/LC#Dxx X -
XFP/OTN11G/#19xxxV/SM/LC X -
XFP/11G/#19xxxL50/SM/LC X X
XFP/8G/#xxxxxL/SM/LC#Dxx X -
SFP+/11GU/#19xxxL50/SM/LC X X
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx X -
SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx X -
SFP/3GSDI/#xxxxxV/SM/LC X -
CFP/4x28G/#19xxx-#19xxxL/SM/LC - X
CFP/4x28G/#DCTL/SM/LC - X

Loop Functionality Support


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Facility Side Terminal Loops Facility Loops


WCC-PCTN-10G client side X X
network side X X
2WCC-PCN-10G client side X X
network side X X
10TCC-PCN-2G7US+10G client side X X
network side X X
4TCC-PCTN-2G7+10G client side1 X X
network side X X
10TCC-PCTN-4GUS+10G client side1 X X
network side X X
10TCC-PCTN-10G+100GB client side X X
network side X X
10WXC-PCN-10G client side - -
network side - -
2TWCC-PCN-2G7U client side1 X X
network side X X
WCC-PC1N-2G7U client side X X
network side X X
WCC-PCTN-100GA client side X X
network side X X

Module and System Specification 753


Facility Side Terminal Loops Facility Loops
WCC-PCTN-100GB client side X X
network side X X
4TCA-PCN-4GU+4G client side X X
network side X X
4TCA-PCN-4GUS+4G client side X X
network side X X
WCA-PCN-2G5U client side – X
network side1 – X
10PCA-PCN-1G3+10G client side X X
network side X X
2PCA-PCN-10G client side1 X X
network side X X
2WCA-PCN-10G client side - X
network side - X
WCE-PCN-100G client side X X
network side X X
WCE-PCN-100GB client side X X
network side X X
4WCE-PCN-16GFC client side - X2
network side - X2
5TCE-PCTN-10GU+10G client side1 X X

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
network side X X
5TCE-PCTN-10GU+AES10G client side 1 X X
network side3 X X
5TCE-PCN-10GU+10G client side1 X X
network side X X
5TCE-PCN-10GU+AES10G client side 1 X X
network side3 X X
5TCE-PCTN-8GU+10GS client side1 X X
network side X X
5TCE-PCTN-8GU+AES10GS client side 1 X X
network side3 X X
10TCE-PCN-10G+100G client side1 X X
network side X -
10TCE-PCN-10G+100G-GF client side 1 X X
network side X -
10TCE-PCN-16GU+AES100G client side1 X X
network side - -
1. on individual ports
2. only supported for 8 G FC and 10 GbE LAN PHY
3. loop on the network port is only allowed for bypass applications when encryption is disabled

754 Module and System Specification


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Channel Module Protection Capabilities


Module and System Specification

Versatile
Switched Channel Card Client Channel Card
Channel Protection Path Protection
Protection/ Protection Protection
Restoration
WCC-PCTN-100GB P
- (Uni/Bi,
Rev/Non-Rev)
10TCC-PCTN-10G+100GB P
(Uni/Bi,
Rev/Non-Rev)
WCC-PCTN-10G P
R (Uni/Bi,
(Bi, Non-Rev)
Rev/Non-Rev)1
4TCC-PCTN-2G7+10G R P
(Bi, Non-Rev) (Bi, Rev/Non-Rev)
10TCC-PCTN-4GUS+10G R P
(Bi, Non-Rev) (Bi, Rev/Non-Rev)
10TCC-PCN-2G7US+10G P
R P
(Uni/Bi,
(Bi, Non-Rev) (Bi, Non-Rev)
Rev/Non-Rev)
10WXC-PCN-10G R
(Bi, Non-Rev)
2WCC-PCN-10G P P
R

Appendix A Overview of Modules


(Uni/Bi, (Uni/Bi,
(Bi, Non-Rev)
Rev/Non-Rev) Rev/Non-Rev)
2TWCC-PCN-2G7U P
R P
(Uni/Bi,
(Bi, Non-Rev) (Bi, Rev/Non-Rev)
Rev/Non-Rev)
WCC-PC1N-2G7U P
R (Uni/Bi,
(Bi, Non-Rev)
Rev/Non-Rev)1
2WCA-PCN-10G P P
(Bi, Non-Rev) (Bi, Non-Rev)
755
756

Versatile
Switched Channel Card Client Channel Card
Channel Protection Path Protection
Protection/ Protection Protection
Restoration
4TCA-PCN-4GU+4G P P P P
(Bi, Non-Rev) (Bi, Non-Rev) (Bi, Non-Rev) (Bi, Non-Rev)
4TCA-PCN-4GUS+4G R P P P
(Bi, Non-Rev) (Bi, Non-Rev) (Bi, Non-Rev) (Bi, Non-Rev)
WCA-PCN-2G5U P P
(Bi, Non-Rev) (Bi, Non-Rev)
WCE-PCN-100G R P
(Bi, Non-Rev) (Bi, Rev/Non-Rev)
WCE-PCN-100GB R P
(Bi, Non-Rev) (Bi, Rev/Non-Rev)
4WCE-PCN-16GFC P
(Bi, Non-Rev)
5TCE-PCTN-10GU+10G P
P
(Uni/Bi,
(Bi, Non-Rev)
Rev/Non-Rev)
5TCE-PCTN-10GU+AES10G P
R
(Uni/Bi,
(Bi, Non-Rev)
Rev/Non-Rev)
5TCE-PCN-10GU+10G P P
(Bi, Non-Rev) (Bi, Non-Rev)
5TCE-PCN-10GU+AES10G P P
(Bi, Non-Rev) (Bi, Non-Rev)
Module and System Specification

5TCE-PCTN-8GU+10GS P
(Bi, Non-Rev)
5TCE-PCTN-8GU+AES10GS R
(Bi, Non-Rev)
10TCE-PCN-16GU+AES100G R
(Bi, Non-Rev)
10TCE-PCN-10G+100G-GF R
(Bi, Non-Rev)
1. for “Bidirectional” only “Non-Revertive”

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Appendix A Overview of Modules

Legend
The following legend refers to the table for “Channel Module Protection
Capabilities” which shows the supported protection schemes of the channel
modules.
R = Restoration Bi = Bidirectional
Rev = Revertive Uni = Unidirectional
P = Protection Non-Rev = Non-Revertive
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification 757


Channel Module Regeneration Capabilities
758

10TCC-PCTN-4GUS+10G
4TCC-PCTN-2G7+10G
4TCC-PCTN-10G+40G

2TWCC-PCN-2G7U
WCC-PC1N-2G7U

WCA-PCN-2G5U
WCC-PCTN-10G

2WCC-PCN-10G

2WCA-PCN-10G
Regeneration Capabilities

4TCC-PCTN-10G+40G BB,
-- -- -- -- -- -- -- --
PN
WCC-PCTN-10G BB, BN, PS
-- -- -- -- -- BC, PN --
PS BC, PS
4TCC-PCTN-2G7+10G BB, BB,
-- -- -- BC, PS -- BC, PN --
PS PN
10TCC-PCTN-4GUS+10G BB, BB, BN, PS
-- -- -- -- BC, PS --
PS PN BC, PS
10TCC-PCN-2G7US+10G BB, BN, PS
-- -- -- -- -- -- --
PS BC, PS
2WCC-PCN-10G BB, BN, PS
-- -- -- -- -- BC, PS --
PS BC, PS
2TWCC-PCN-2G7U BB,PS
-- -- -- -- -- BC, PS -- BN, PS
Module and System Specification

BC,PS
WCC-PC1N-2G7U BB,PS
-- -- -- -- -- -- -- BN, PS
BC,PS

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification

5TCE-PCTN-8GU+AES10GS
5TCE-PCTN-10GU+AES10G
5TCE-PCN-10GU+AES10G

5TCE-PCTN-8GU+10GS
5TCE-PCTN-10GU+10G
5TCE-PCN-10GU+10G
4TCA-PCN-4GUS+4G
4TCA-PCN-4GU+4G

4WCE-PCN-16GFC
WCA-PCN-2G5U
WCC-PCTN-10G

2WCC-PCN-10G

2WCA-PCN-10G
Regeneration Capabilities

2PCA-PCN-10G BB, PS BC, PS BC, PS -- -- -- -- -- -- -- -- -- --


10PCA-PCN-1G3+10G BB, PS BC, PS BC, PS -- -- -- -- -- -- -- -- -- --
2WCA-PCN-10G -- -- BC, PS -- -- -- -- -- -- -- -- -- --
4TCA-PCN-4GU+4G BN, PS
-- -- -- BC, PS -- -- -- -- -- -- -- -- --
BB, PN
4TCA-PCN-4GUS+4G -- -- -- -- BN, PS -- -- -- -- -- -- -- --
WCA-PCN-2G5U -- -- -- -- -- BN, PS -- -- -- -- -- -- --
4WCE-PCN-16GFC -- -- -- -- -- -- BB, PN -- -- -- -- -- --
5TCE-PCTN-10GU+10G -- -- BC, PS1 -- -- -- -- BB, PN -- -- --
5TCE-PCTN-10GU+AES10G BB,
-- -- BC, PS1 -- -- -- -- -- -- --
PN
-- --
5TCE-PCN-10GU+10G -- BC, PS -- -- -- -- -- BB, PN -- -- -- -- --
5TCE-PCN-10GU+AES10G -- BC, PS -- -- -- -- -- -- BB, PN -- -- -- --

Appendix A Overview of Modules


5TCE-PCTN-8GU+10GS BB,
-- BC, PS BC, PN -- -- -- -- -- -- -- -- --
PN
5TCE-PCTN-8GU+AES10GS BB,
-- BC, PS BC PN -- -- -- -- -- -- -- -- --
PN
1. Using XFP/11G/Dxxxx.xxV/SM/LC#Dxx and XFP/11G/DCTV/SM/LC supporting data rates between 9.9532 Gbit/s and 11.3176 Gbit/s at a max.
ambient temperature of 45°C. In this application the 5TCE module has to be provisioned to a data rate between 9.9532 Gbit/s and 10.709 Gbit/s
even if the transported data rate is higher.
759
Legend
The following legend lists the abbreviations and their meanings for regeneration
and protection functionality between the FSP 3000R7 channel modules.

General -- = no regeneration and protection supported

Regeneration US = Unidirectional - single module regeneration


BC = Bidirectional regenerator (network-to-client)
BN = Bidirectional regenerator (network-to-network)
BB = Back-to-back regeneration

Protection PS = Protection (channel or channel card protection) supported


PN = Protection (channel or channel card protection) not supported

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

760 Module and System Specification


Appendix A Overview of Modules

Data Rates and Services


The following table lists all data rates and their corresponding services
supported by the FSP 3000R7.
Data Rates Services
125 Mbit/s Fast Ethernet (FE)
155 Mbit/s STM-1,
OC-3,
ATM 155
200 Mbit/s ESCON
270 Mbit/s SD-SDI
360 Mbit/s SD-SDI
622 Mbit/s STM-4,
OC-12,
ATM 622
1.0625 Gbit/s 1G FC
1.250 Gbit/s GbE
1.485 Gbit/s HD-SDI
2.125 Gbit/s 2G FC
2.488 Gbit/s F2488
2.5 Gbit/s STM-16,
OC-48
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

2.666057 Gbit/s OTU1


4.25 Gbit/s 4G FC
5.0 Gbit/s 5G IB
8.5 Gbit/s 8G FC
9.95328 Gbit/s F9953,
STM-64,
OC-192,
10 GbE WAN PHY
10.0 Gbit/s 10G IB
10.3125 Gbit/s 10 GbE LAN PHY
10.51875 Gbit/s 10G FC
10.6642 Gbit/s STM64 / OC192 wrapped into OTU2 without
stuffing
10.7092 Gbit/s OTU2
10.7595 Gbit/s Proprietary OTU2 data rate of the network port
of the 5TCE-PCTN-10GU+10G,
5TCE-PCTN-10GU+AES10G for transparent
transport of 10G IB.
10.9747 Gbit/s Proprietary OTU2 data rate of the network port
of the 5TCE-PCTN-10GU+10G and
5TCE-PCTN-10GU+AES10G for transparent
transport of 8G FC
11.0032 Gbit/s OTU2V
11.0491 Gbit/s OTU1e (OTU2LAN without stuffing)
11.0957 Gbit/s OTU2e (OTU2LAN with stuffing)

Module and System Specification 761


Data Rates Services
11.3176 Gbit/s OTU2f (10G FC wrapped into OTU2 with
stuffing)
14.025 Gbit/s 16G FC
4 x 10.3125 Gbit/s 40 GbE (F41250)
39.81312 Gbit/s STM-256,
OC-768
43.01841 Gbit/s OTU3
103.1 Gbit/s 100 GbE
10 x 10.3125 Gbit/s 100 GbE (F103125)
111.8 Gbit/s OTU4
120.579 Gbit/s OTU4V

Please find in Table 1340, Table 1341, Table 1342 and Table 1343 the data
rates and services supported by each channel module.

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

762 Module and System Specification


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Channel Module Services


Module and System Specification

Table 1340: Services Part 1


Services

OTU1e, OTU2e
STM-4, OC-12

Subset G.709

Fast Ethernet
STM-1, OC-3

STM-256,
STM-16,

STM-64,
OC-192

OC-768

HD-SDI
SD-SDI

OTU2V

OTU4V
OC-48
F2488

F9953

OTU1

OTU2

OTU2

OTU4
Mode
WCC-PCTN-100GA T N C
WCC-PCTN-100GB T N C
WCC-PCTN-10G W C N N
T C/N C/N C/N
4TCC-PCTN-2G7+10G M C C N N
10TCC-PCTN-4GUS+10G M C C C N N
10TCC-PCN-2G7US+10G M C C C C N
10TCC-PCTN-10G+100GB M C C C N
10WXC-PCN-10G XC C/N C/N 1

2WCC-PCN-10G T C/N C/N C/N


2TWCC-PCN-2G7U M N N
T C/N C/N
WCC-PC1N-2G7U W C N
T C/N C/N C/N C/N

Appendix A Overview of Modules


4TCA-PCN-4GUS+4G M C C
WCA-PCN-2G5U T C/N C/N C/N C/N C/N C/N C/N
WCE-PCN-100G T N
WCE-PCN-100GB T N
5TCE-PCTN-10GU+10G M N
F N
T N
763
Table 1340: Services Part 1 (Continued)
764

Services

OTU1e, OTU2e
STM-4, OC-12

Subset G.709

Fast Ethernet
STM-1, OC-3

STM-256,
STM-16,

STM-64,
OC-192

OC-768

HD-SDI
SD-SDI

OTU2V

OTU4V
OC-48
F2488

F9953

OTU1

OTU2

OTU2

OTU4
Mode
5TCE-PCTN-10GU+AES10G M C N
F N
T C N
5TCE-PCN-10GU+10G M C N
F N
T C N
5TCE-PCN-10GU+AES10G M C N
F N
T C N
5TCE-PCTN-8GU+10GS M N
F N
5TCE-PCTN-8GU+AES10GS M N
F N
10TCE-PCN-10G+100G M C N
10TCE-PCN-10G+100G-GF M C N
10TCE-PCN-16GU+AES100G M N
Module and System Specification

1. OTU2e on C/N only

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 1341: Services Part 2


Module and System Specification

Services

Networking Proprietary
10GbE WAN PHY

Coupling Link 1G

Coupling Link 2G
10GbE LAN PHY
Gigabit Ethernet

10G FC/FICON

10G InfiniBand
1G FC/FICON

2G FC/FICON

4G FC/FICON

8G FC/FICON

ADVA Optical
5G InfiniBand
100GbE

ESCON
16G FC
40GbE
Mode
2WCC-PCN-10G T C/N C/N C/N
2TWCC-PCN-2G7U M C C C
WCC-PCTN-100GA T C
WCC-PCTN-100GB T C
WCC-PCTN-10G W C C
T C/N C/N C/N
10TCC-PCTN-4GUS+10G M C C C C
10TCC-PCN-2G7US+10G M C
10TCC-PCTN-10G+100GB M C C
10WXC-PCN-10G T C/N
WCC-PC1N-2G7U T C/N
WCC-PC-2G7U T C/N
2PCA-PCN-10G M C N
10PCA-PCN-1G3+10G M C N

Appendix A Overview of Modules


2WCA-PCN-10G T C/N C/N C/N C/N C/N
4TCA-PCN-4GU+4G M C C C C C N
T C/N
4TCA-PCN-4GUS+4G M C N
WCA-PCN-2G5U T C/N C/N C/N C/N C/N C/N
5TCE-PCN-10GU+10G M C C C C C
F C C C C C
T C C C
765
Table 1341: Services Part 2 (Continued)
766

Services

Networking Proprietary
10GbE WAN PHY

Coupling Link 1G

Coupling Link 2G
10GbE LAN PHY
Gigabit Ethernet

10G FC/FICON

10G InfiniBand
1G FC/FICON

2G FC/FICON

4G FC/FICON

8G FC/FICON

ADVA Optical
5G InfiniBand
100GbE

ESCON
16G FC
40GbE
Mode
5TCE-PCN-10GU+AES10G M C C C C C
F C C C C C
T C C C
5TCE-PCTN-10GU+10G M C C C C C
F C C C C C
T C C C C
5TCE-PCTN-10GU+AES10G M C C C C C
F C C C C C
T C C C C
5TCE-PCTN-8GU+10GS M C C C C
F C C C C C
5TCE-PCTN-8GU+AES10GS M C C C C
F C C C C C
WCE-PCN-100G T C
Module and System Specification

WCE-PCN-100GB T C
4WCE-PCN-16GFC T C/N C/N C/N
10TCE-PCN-10G+100G M C C C
10TCE-PCN-10G+100G-GF M C C C
10TCE-PCN-16GU+AES100G M C C C C C

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Legend
Module and System Specification

The following legend refers to Table 1340 and Table 1341 and lists the abbreviations and their meanings for the services
supported on the FSP 3000R7 channel modules.
C = Client Ports
T = Transponder Mode
M = Multiplexer Mode
N = Network Ports
W = Wrapping Mode
F = Framed Mode

Channel Module Data Rates


Table 1342: Data Rates 1
Data Rates

1.0625 Gbit/s

1.250 Gbit/s

1.485 Gbit/s

2.125 Gbit/s
125 Mbit/s

155 Mbit/s

200 Mbit/s

270 Mbit/s

360 Mbit/s

622 Mbit/s
Mode

2TWCC-PCN-2G7U M C C C
10TCC-PCTN-4GUS+10G M C C C C C
10TCC-PCN-2G7US+10G M C C C
WCC-PC1N-2G7U T C/N C/N C/N
2PCA-PCN-10G M

Appendix A Overview of Modules


10PCA-PCN-1G3+10G M C
4TCA-PCN-4GU+4G M C C C
4TCA-PCN-4GUS+4G M C C C
WCA-PCN-2G5U T C/N C/N C/N C/N C/N C/N C/N C/N C/N C/N
5TCE-PCN-10GU+10G M C C C
F C C C
T
767
Table 1342: Data Rates 1 (Continued)
768

Data Rates

1.0625 Gbit/s

1.250 Gbit/s

1.485 Gbit/s

2.125 Gbit/s
125 Mbit/s

155 Mbit/s

200 Mbit/s

270 Mbit/s

360 Mbit/s

622 Mbit/s
Mode
5TCE-PCN-10GU+AES10G M C C C
F C C C
T
5TCE-PCTN-10GU+10G M C C C
F C C C
T
5TCE-PCTN-10GU+AES10G M C C C
F C C C
T
5TCE-PCTN-8GU+10GS M C C C
F C C C
5TCE-PCTN-8GU+AES10GS M C C C
F C C C

Table 1343: Data Rates 2


Data Rates [Gbit/s]
2.666057

10.51875

39.81312
43.01841
10.6642

10.7092
9.95328

10.3125

10.7595
10.9747
11.0032
11.0491
11.0957

11.3176

120.579
14.025
Mode
2.488

103.1
111.8
Module and System Specification

4.25

10.0
5.0
2.5

8.5

WCC-PCTN-100GA T C C N
WCC-PCTN-100GB T C C N
WCC-PCTN-10G W C C N N N N
C/
T C/N C/N C/N C/N C/N C/N
N
4TCC-PC-2G7+10G M C C N N
10TCC-PCTN-4GUS+10G M C N N

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 1343: Data Rates 2 (Continued)


Module and System Specification

Data Rates [Gbit/s]

2.666057

10.51875

39.81312
43.01841
9.95328

10.3125

10.6642

10.7092
10.7595
10.9747
11.0032
11.0491
11.0957

11.3176

120.579
14.025
Mode
2.488

103.1
111.8
4.25

10.0
2.5

5.0
8.5
10TCC-PCN-2G7US+10G M C C N
10TCC-PCTN-10G+100GB M C C C C N
10WXC-PCN-10G C/N C/N C/N
2WCC-PCN-10G C/
T C/N C/N C/N C/N C/N
N
2TWCC-PCN-2G7U T C/N C/N
M N N
WCC-PC1N-2G7U W C N
T C/N C/N
2PCA-PCN-10G M C/N
10PCA-PCN-1G3+10G M N
2WCA-PCN-10G T C/N C/N C/N C/N C/N C/N
4TCA-PCN-4GU+4G M C/N
T C/N
4TCA-PCN-4GUS+4G M N
WCA-PCN-2G5U T C/N C/N C/N
WCE-PCN-100G T C N
WCE-PCN-100GB T C N
4WCE-PCN-16GFC T C/N C/N C/N

Appendix A Overview of Modules


5TCE-PCN-10GU+10G M C C C N
F C C N
T C C C C N N N N
5TCE-PCN-10GU+AES10G M C C C N
F C C N
T C C C C N N N N
5TCE-PCTN-10GU+10G M C C N
F C C N
T C C C C N N N N
769
Table 1343: Data Rates 2 (Continued)
770

Data Rates [Gbit/s]

2.666057

10.51875

39.81312
43.01841
9.95328

10.3125

10.6642

10.7092
10.7595
10.9747
11.0032
11.0491
11.0957

11.3176

120.579
14.025
Mode
2.488

103.1
111.8
4.25

10.0
2.5

5.0
8.5
5TCE-PCTN-10GU+AES10G M C C C N
F C C N
T C C C C C N N N N
5TCE-PCTN-8GU+10GS M C
F C C N
5TCE-PCTN-8GU+AES10GS M C
F C C N
10TCE-PCN-10G+100G M C C C N
10TCE-PCN-10G+100G-GF M C C C N
10TCE-PCN-16GU+AES100G M C C C N

Legend
The following legend refers to Table 1342 and Table 1343 and lists the abbreviations and their meanings for the data
rates supported on the FSP 3000R7 channel modules.
C = Client Ports
N = Network Ports
T = Transponder Mode
W = Wrapping Mode
M = Multiplexer
Module and System Specification

F = Framed Mode

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Channel Module In-band Management Support


Module and System Specification

Management Protocols
Proprietary
ECC for Proprietary
GCCOS GCCO GCC1 GCC2 LDCC SDCC
[kbit/s] [kbit/s] [kbit/s] [kbit/s] [kbit/s] [kbit/s]
wrapped framing1
10 GbE [kbit/s]
[kbit/s]
WCC40GT-D C
N 1312 1312 1312
4TCC40GT-D C
N 5271 5271 5271
WCC10GT-D C 82 1312 1312 1312 192 1359
WCC10GT-LN N 82 1312 1312 1312 192 1359
WCC100GB C 13702 13702 13702
N 13702 13702 13702
4TCC10GT-D C 82 326 326 326 192
4TCC10GT-LN N 82 1312 1312 1312
10TCC10GT-D C
10TCC10GT-LN N 82 1312 1312 1312 576 192
10TCCS10GT-D C
10TCCS10GT-LN N 82 1312 1312 1312 576 192
10TCC10G C 82 326 326 326 192
N 82 1312 1312 1312

Appendix A Overview of Modules


10TCC100GTB-D C 1312 1312 1312
N 13702 13702 13702
10WXC10G 1312 2
1312 3
2WCC10G C 82 1312 1312 1312 192
N 82 1312 1312 1312 192
2TWCC2G7 C 82 326 326 326 192
N 82 326 326 326 192
771
772

Management Protocols
Proprietary
ECC for Proprietary
GCCOS GCCO GCC1 GCC2 LDCC SDCC
[kbit/s] [kbit/s] [kbit/s] [kbit/s] [kbit/s] [kbit/s]
wrapped framing1
10 GbE [kbit/s]
[kbit/s]
WCC2G7-1N C 82 326 326 326 192
N 82 326 326 326 192
4TCC2G5 C
N 192
2PCA10G 4 C
N
10PCA10G2 C
N
4TCA4G C
N 1000 5
4TCA4GUS C
N 1000
2TCA2G5 C
N 1000
2TCA2G5S C
N 1000
WCE100G C
N 13702
Module and System Specification

WCE100GB C
N 13702
5TCE10GT-D C
N 1312
5TCE10G C
N 1312
5TCE10GTAES-D C
N 1312
5TCE10GAES C
N 1312

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification

Management Protocols
Proprietary
ECC for Proprietary
GCCOS GCCO GCC1 GCC2 LDCC SDCC
[kbit/s] [kbit/s] [kbit/s] [kbit/s] [kbit/s] [kbit/s]
wrapped framing1
10 GbE [kbit/s]
[kbit/s]
5TCES10GT-D C
N 576 192
5TCES10GTAES-D C
N 576 192
10TCE100GAES C
N 13702
10TCE-PCN-10G+100G C
(10TCE100G) N 1312
10TCE-PCN-10G+100G-GF C
(10TCE100G) N 1312
1. This refers specifically to ADVA Optical Networking proprietary framing.
2. ECC on OTU2 (on each traffic port)
3. ECC on OTU2e (on each traffic port)
4. In-band management is provided via Ethernet ELine-PPP (IP over PPP over VLAN EVC) at 1Mbit/s per ECC.
5. Not supported in TRANSW mode.

Appendix A Overview of Modules


773
Channel Module Error Signaling on Client
Port
Laser Off Error Propagation Code
WCC-PCTN-100GA X1 X
WCC-PCTN-100GB X X
WCC-PCTN-10G X X
4TCC-PCTN-2G7+10G X X
10TCC-PCTN-4GUS+10G X X
10TCC-PCN-2G7US+10G X X
10TCC-PCTN-10G+100GB X X
2WCC-PCN-10G X X
2TWCC-PCN-2G7U X X
WCC-PC1N-2G7U X X
2PCA-PCN-10G -- X2
10PCA-PCN-1G3+10G -- X
2WCA-PCN-10G X --
4TCA-PCN-4GU+4G X X3
4TCA-PCN-4GUS+4G X X4
WCA-PCN-2G5U X --
WCE-PCN-100G X --

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
WCE-PCN-100GB X --
4WCE-PCN-16GFC X --
5TCE-PCTN-10GU+10G X X
5TCE-PCN-10GU+10G X X
5TCE-PCTN-10GU+AES10G X X
5TCE-PCN-10GU+AES10G X X
5TCE-PCTN-8GU+10GS X X
5TCE-PCTN-8GU+AES10GS X X
10TCE-PCN-10G+100G X --
10TCE-PCN-10G+100G-GF X --
10TCE-PCN-16GU+AES100G X --
1. Ethernet client only
2. Sending Idle characters
3. Not in TransW mode
4. Not for STM-16/OC-12

774 Module and System Specification


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Pluggable Interfaces
Module and System Specification

XFP/SFP/CFP Gray Interfaces

Parameters
First Fiber / Cable Nominal Sensitivity
Data Rates [Gbit/s] Output Power [dBm]
Rel. Type Wavelength [nm] Port [dBm]1
XFP/10G/850I/MM/LC 7.01 MM 850 9.9532 / 10.3125 / -8.0 to -1.0 -11.0 to -1.0
10.51875
XFP/11G/1310S/SM/LC 7.02 SM 1310 9.9532 / 10.3125 / -6.0 to -1.0 -13.0 to -1.0
10.51875 / 10.6642 /
10.709 / 11.0491 /
11.0957 / 11.317
XFP/11G/1550L/SM/LC 7.1 SM 1550 9.9532 / 10.3125 / -1.0 to +2.0 -11.0 to -1.0
10.51875 / 10.6642 /
10.709 / 11.0491 /
11.0957 / 11.317
XFP/8G/1310S/SM/LC 9.2 SM 1310 4.25 / 8.5 -6.0 to -1.0 -10.0 to +0.5
XFP/8G/850I/MM/LC 9.2 MM 850 4.25 / 8.5 -8.0 to -1.0 -11.0 to -1.0
SFP+/16GFC/1310S/SM/LC 11.2 SM 1310 4.25 / 8.5 / 14.025 -5.0 to +2.0 -12.0 to +2.0
SFP+/16GFC/850I/MM/LC 11.2 MM 850 4.25 / 8.5 / 14.025 -8.0 to 0.0 -10.0 to -1.0
SFP+CDR/10GU/1550L/SM/LC 11.2 SM 1550 8.5 / 9.9533 / -5.0 to +4.0 -16.0 to -1.0
10.0 / 10.3125
SFP+CDR/11GU/1310S/SM/LC 11.2 SM 1310 8.5 / 9.9533 / -6.0 to -1.0 -11.0 to +0.5

Appendix A Overview of Modules


10.0 / 10.3125 /
10.709 / 11.0491 /
11.0957 / 11.3176
SFP+CDR/11GU/CxxxxL/SM/LC 12.3 SM 1471, 1491, 8.5 / 9.9532 / 10.0 / -4.7 to +4.0 -16.0 to -1.0
1511, 1531, 10.3125 /10.518 /
1551, 1571, 10.709 / 11.0491 /
1591, 1611 11.0957 / 11.3176
775
776

Parameters
First Fiber / Cable Nominal Sensitivity
Data Rates [Gbit/s] Output Power [dBm]
Rel. Type Wavelength [nm] Port [dBm]1
SFP+CDR/11GU/CxxxxS/SM/LC 12.3 SM 1271, 1291, 9.9532 / 10.0 / -5.0 to 0.0 -13.0 to 0.0
1311, 1331 10.3125 / 10.5187 /
10.709 / 10.754 /
11.0491 / 11.0957 /
11.3176
SFP+CDR/10GU/850I/MM/LC 11.2 MM 850 8.5 / 10.3125 -8.0 to 0.0 -10.0 to -1.0
SFP+/10G/1310S/SM/LC 9.3 SM 1310 5.0 / 8.5 / 9.953 / -8.0 to -0.5 -14.0 to 0.0
10.0 / 10.3125 /
10.51875
SFP+/10G/850I/MM/LC 9.3 MM 850 5.0 / 8.5 / 10.0 / -8.0 to -1.0 -11.0 to -1.0
10.3125 / 10.51875
SFP+/11GU/CxxxxL/SM/LC 12.1 SM 1471, 1491, 8.5 / 9.9532 / 10.0 / -4 to +4 -16.0 to -1.0
1511, 1531, 10.3125 / 10.5187 /
1551, 1571, 10.709 / 10.754 /
1591, 1611 10.7595 / 10.9747 /
11.0491 / 11.0957 /
11.3176
SFP+/11GU/1310S/SM/LC 12.1 SM 1310 5.02 / 8.5 / 9.9533 / -8 to -1 -13.0 to -1.0
10.0 / 10.3125 /
10.5187 / 10.709 /
10.7595 / 10.9747 /
11.0491 / 11.0957 /
Module and System Specification

11.3176
SFP+/11GU/850I/MM/LC 12.1 MM 850 5.02 / 8.5 / 9.9533 / -8 to -1 -11.0 to -1.0
10.0 / 10.3125 /
10.5187 / 10.709 /
10.754 / 10.9747 /
11.0491 / 11.0957 /
11.3176
SFP+/8GU/1310S/SM/LC 9.3 SM 1310 2.125 / 4.250 / 8.5 -8.5 to 0.5 at 8.5 Gbit/s -14.0 to 0.0
-8.5 to -3.0 at 2.25 / 4.25
Gbit/s

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification

Parameters
First Fiber / Cable Nominal Sensitivity
Data Rates [Gbit/s] Output Power [dBm]
Rel. Type Wavelength [nm] Port [dBm]1
SFP+/8GU/850I/MM/LC 9.3 MM 850 2.125 / 4.250 / 8.5 -9.0 to -2.0 -10.0 to 1.0
SFP/4GU/1310S/SM/LC 7.01 SM 1310 1.0625 / 2.125 / 4.25 -9.0 to -1.0 -18.0 to -1.0
SFP/4GU/850I/MM/LC 7.01 MM 850 1.0625 / 2.125 / 4.25 -10.0 to -2.5 -14.0 to 0.0
SFP/2G5U/1310S/SM/LC 7.01 SM 1310 0.1 to 2.67 -10.0 to -3.0 -16.0 to -3.0
(HW Rev. 1.0.1) MM
SFP/2G5U/1310S/SM/LC 7.1 SM 1310 0.1 to 2.67 -5.0 to 0.0 -18.0 to 0.0
(HW Rev. 1.0.2) MM
SFP/2G5U/1310S/SM/LC 10.1 SM 1310 0.1 to 2.67 -5.0 to 0.0 -18.0 to 0.0
(HW Rev. 2.01) MM
SFP/2G5U/1310L/SM/LC 7.01 SM 1310 0.1 to 2.67 -2.0 to +3.0 -27.0 to -9.0
SFP/HS/1310S/SM/LC 7.01 SM 1310 1.0625 / 1.25 -10.0 to -3.0 -19.0 to -3.0
MM
SFP/CL/1310I/SM/LC 7.01 SM 1310 0.1 to 2.67 -10.0 to -3.0 -19.0 to -3.0
MM
SFP/2G1/850I/MM/LC 7.01 MM 850 1.0625 / 1.25 / 2.125 -10.0 to -3.0 -15.0 to -3.0
/ 2.5
SFP/GBE/1310S/SM/LC/TIN 10.2 SM 1310 1.25 -9.0 to -3.0 -20.0 to -3.0
SFP/GBE/1310L/SM/LC/TIN 10.2 SM 1310 1.25 -5.0 to 2.0 -23.0 to -3.0
SFP/GBE/1550V/SM/LC/TIN 10.2 SM 1550 1.25 0.0 to 5.0 -24.0 to -3.0
SFP/GBE/850I/MM/LC/TIN 10.2 SM 850 1.25 -9.5 to 0.0 -17.0 to 0.0
SFP/GBE/B1310S/SM/LC 12.1 SM 1310 1.25 -9.0 to -3.0 -20.0 to -3.0

Appendix A Overview of Modules


SFP/GBE/B1490S/SM/LC 12.1 SM 1490 1.25 -9.0 to -3.0 -20.0 to -3.0

SFP/GBE/B1310L/SM/LC 12.1 SM 1310 1.25 -2.0 to +2.0 -23.0 to -3.0

SFP/GBE/B1490L/SM/LC 12.1 SM 1490 1.25 -3.0 to +2.0 -23.0 to -3.0


SFP/GBE/ELECTRICAL/RJ45 7.01 CAT 6 - - - -
SFP/3GSDI/ELECTRICAL/DIN 11.2 Belden - 0.27 / 0.36 / 1.485 / - -
1694A, 75 Ω 2.97
777
778

Parameters
First Fiber / Cable Nominal Sensitivity
Data Rates [Gbit/s] Output Power [dBm]
Rel. Type Wavelength [nm] Port [dBm]1
SFP/3GSDI/ELECTRICAL/HBNC 11.2 Belden - 0.27 / 0.36 / 1.485 / - -
1694A, 75 Ω 2.97
CFP/112G/LR10R/SM/LC 11.1 SM 1523, 1531, 1539 103.125 / 111.81 -4.5 to 3.53 -9.5 to 3.54
1547, 1555, 1563
1571, 1579, 1587
1595
CFP/112G/LR4/SM/LC 11.1 SM 1295.56, 1300.05 103.125 / 111.81 -4.3 to 4.53 -10.6 to 4.54
1304.58, 1309.14
CFP/103G/SR10/MM/MPO 12.1 MM 840 to 860 MM103.125 -7.6 to+2.45 -9.5 to +2.44
1. Sensitivity and reach depend on the data rate, fiber type and client equipment interface signal quality.
2. 5.0 Gbit/s for HW rev. 2.01 or newer
3. Average launch power
4. Average receive power
5. Transmitter output power range, each lane (min) is informative and not the principal indicator of signal strength. A transmitter with output power
below this value cannot be compliant; however, a value above this does not ensure compliance.
Module and System Specification

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

XFP/SFP/CFP Colored Interfaces


Module and System Specification

Parameters

Fiber Type
Sensitivity

First Rel.
Opt.
Wave- Output Network Port
Data Rates [Gbit/s] dispersion
length Power [dBm]
[dBm]1 load [ps/nm]

XFP/16GFC/#xxxxxL/SM/LC#Dxx 11.2 SM DWDM 4.25 / 8.5 / 14.025 0.0 to +4.0 -13.0 to 0.0 0 to +400
XFP/16GFC/#19xxxL50/SM/LC 12.2 SM DWDM 4.25 / 8.5 / 14.025 0.0 to +4.0 -12.0 to 0.0 -100 to +100
XFP/11G/DCTV/SM/LC 9.3 SM DWDM 9.9532 /10.3125 / 10.51875 / 300 to 1000
10.6642 / 10.709 / 11.0032 / -1.0 to +3.0 -22.0 to -7.0
11.0491 / 11.0957 / 11.3176
XFP/11G/DCTLNR/SM/LC 10.3 SM DWDM 9.9532 /10.3125 / 10.51875 / -300 to +300
10.6642 / 10.709 / 11.0032 / -1.0 to +3.0 -17.0 to 0.0
11.0491 / 11.0957 / 11.3176
XFP/11G/DCTLN/SM/LC 11.1 SM DWDM 9.9532 /10.3125 / 10.51875 /
10.6642 / 10.709 / 11.0032 / 0.0 to +3.0 -16.0 to 0.0 -300 to +300
11.0491 / 11.0957 / 11.3176
XFP/11G/Dxxxx.xxV/SM/LC#Dxx 8.2 SM DWDM 9.9532 / 10.3125 / 10.51875
(HW Rev. 2.00) 10.6642 / 10.709 / 11.0032 0.0 to +4.0 -23.0 to -9.0 100 to 800
11.0491 / 11.0957 / 11.3176
XFP/11G/Dxxxx.xxV/SM/LC#Dxx 9.3 SM DWDM 9.9532 / 10.3125 / 10.51875
(HW Rev. 4.01) 10.6642 / 10.709 / 11.0032 0.0 to +4.0 -23.0 to -7.0 100 to 800
11.0491 / 11.0957 / 11.3176
XFP/11G/Dxxxx.xxV/SM/LC#Dxx 9.3 SM DWDM 9.9532 / 10.3125 / 10.51875
(HW Rev. 5.01) 10.6642 / 10.709 / 11.0032 0.0 to +4.0 -23.0 to -7.0 100 to 800

Appendix A Overview of Modules


11.0491 / 11.0957 / 11.3176
XFP/11G/#19xxxL50/SM/LC 12.2 SM DWDM 9.9532 / 10.3125 / 10.51875
10.6642 / 10.709 / 11.0032 -1.0 to +4.0 -14.0 to 0.0 -300 to +300
11.0491 / 11.0957 / 11.3176
XFP/OTN11G/#19xxxV/SM/LC 11.1 SM DWDM 11.0957 0.0 to +3.0 -25.0 to -7.02 0
XFP/8G/#xxxxxL/SM/LC#Dxx 9.1 SM DWDM 4.25 / 8.5 -0.5 to +4.0 -22.0 to -7.0 300 to 600
XFP/11G/CxxxxL/SM/LC 8.2 SM CWDM 9.9532 / 10.3125 / 10.51875 0
10.6642 / 10.709 / 11.0491 / 0.0 to+ 4.0 -17.0 to -9.0
11.0957
779
780

Parameters

Fiber Type
Sensitivity

First Rel.
Opt.
Wave- Output Network Port
Data Rates [Gbit/s] dispersion
length Power [dBm]
[dBm]1 load [ps/nm]

XFP/11G/CxxxxV/SM/LC 8.2 SM CWDM 9.9532 / 10.3125 / 10.51875 0


10.6642 / 10.709 / 11.0491 / 0.0 to +4.0 -22.0 to -9.0
11.0957
XFP/8G/CxxxxL/SM/LC 11.1 SM CWDM 4.25 / 8.5 -1.0 to +4.0 -16.0 to -1.0 0
SFP+/11GU/#19xxxL50/SM/LC 12.3 SM DWDM 3
-16.0 to -1.0 0
8.5 to 11.3176 0.0 to +4.0
-18.0 to -1.03
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx 8.1 SM DWDM 1.0625 to 4.25 +2.0 to +5.0 -23.0 to -9.0 0
SFP/4GU/CxxxxV/SM/LC  8.1 SM CWDM 0
1.0625 to 4.25 +2.0 to +5.0 -23.0 to -9.0
(HW Rev. 2.01)
SFP/4GU/CxxxxV/SM/LC  9.3 SM CWDM 0
1.0625 to 4.25 +1.0 to +5.0 -23.0 to -9.0
(HW Rev. 3.01)
SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx 7.01 SM DWDM 0.155 to 2.67 +4.0 to +7.0 -28.0 to -9.0 100 to 800
SFP/2G5U/CxxxxV/SM/LC 9.1 SM CWDM -300 at
0.1 to 2.67 0.0 to+ 5.0 -28.0 to -9.0
(1271 nm ... 1451 nm) 2.67 Gbit/s
SFP/2G5U/CxxxxV/SM/LC 7.01 SM CWDM -1250 at 2.67
0.1 to 2.67 0.0 to +5.0 -28.0 to -9.0
(1471 nm ... 1611 nm) Gbit/s
SFP/2G5U/CxxxxL/SM/LC 7.01 SM CWDM 0.1 to 2.67 0.0 to +5.0 -20.0 to 0.0 -1250
SFP/4GU/CxxxxL/SM/LC SM CWDM 1.0625 to 4.25 +1.0 to +5.0 0
1271 nm - 1451 nm 9.3 -16.0 to -6.0
1471 nm - 1611 nm 7.1 -16.0 to 0.0
Module and System Specification

SFP/3GSDI/#xxxxxV/SM/LC 11.2 SM DWDM 0.27 to 2.97 0.0 to +3.0 -30.0 to -9.0 0.0 to +700
SFP/FE/C1490U/SM/LC 8.1 SM CWDM 0.125 0.0 to +4.0 -40.0 to -9.0 0
SFP/FE/C1510U/SM/LC 7.1 SM CWDM 0.125 0.0 to +4.0 -40.0 to -9.0 0
SFP/FE/C1490V/SM/LC 8.2 SM CWDM 0.125 0.0 to +4.0 -30.0 to 0.0 0
SFP/FE/C1510V/SM/LC 8.2 SM CWDM 0.125 0.0 to +4.0 -30.0 to 0.0 0
SFP/FE/D1528.77E/SM/LC 8.2 SM DWDM 0.125 +4.0 to +7.0 -42.0 to -10.0 0
SFP/FE/Dxxxxx.xxV/SM/LC 11.2 SM DWDM 0.125 0.0 to +4.0 -38.0 to -15.0 0.0 to 800
CFP/4x28G/#19xxx-#19xxxL/SM/LC 11.2 SM DWDM 103.125 / 111.81 +0.0 to +3.0 -10.0 to +3.0 0
CFP/4x28G/#DCTL/SM/LC 11.2 SM DWDM 103.125 / 111.81 +0.0 to +3.0 -10.0 to +3.0 0

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Module and System Specification

1. Sensitivity and reach depend on the data rate, fiber type and client equipment interface signal quality.
2. Depends on OSNR and dispersion.
3. Depends on BER

Assignment of Pluggable Transceivers


XFPs at the Client Ports
XFPs

XFP/11G/Dxxxx.xxV/SM/LC#Dxx
XFP/16GFC/#19xxxL50/SM/LC

XFP/OTN11G/#19xxxV/SM/LC

XFP/8G/#xxxxxL/SM/LC#Dxx

XFP/11G/#19xxxL50/SM/LC
XFP/11G/DCTLNR/SM/LC

XFP/11G/CxxxxV/SM/LC
XFP/11G/DCTLN/SM/LC

XFP/11G/CxxxxL/SM/LC

XFP/11G/1310S/SM/LC
XFP/11G/1550L/SM/LC
XFP/11G/DCTV/SM/LC

XFP/8G/CxxxxL/SM/LC

XFP/8G/1310S/SM/LC
XFP/10G/850I/MM/LC

XFP/8G/850I/MM/LC
WCC-PCTN-10G-LN#DC
WCC-PCTN-10G-V#DC X X X X X X

Appendix A Overview of Modules


WCC-PCTN-10G-V#DL
2WCC-PCN-10G X X X X X X X X X X X X X X
2PCA-PCN-10G X X X X X X X X
2WCA-PCN-10G X X X X X X X X X X X X X
10WXC-PCN-10G X X X X X X X X X
781
Module and System Specification 782

2PCA-PCN-10G
XFPs

2WCA-PCN-10G
2WCC-PCN-10G

10WXC-PCN-10G

4WCE-PCN-16GFC
10PCA-PCN-1G3+10G
10TCC-PCN-2G7US+10G
XFP/16GFC/#xxxxxL/SM/LC#Dxx
XFP/16GFC/#19xxxL50/SM/LC
XFP/11G/#19xxxL50/SM/LC
XFP/11G/Dxxxx.xxV/SM/LC#Dxx

X X X X
X X X
X
X X
X X
XFP/OTN11G/#19xxxV/SM/LC
XFPs at the Network Ports

XFP/11G/DCTV/SM/LC

X
X
X X X
X X X
XFP/11G/DCTLNR/SM/LC
XFP/11G/DCTLN/SM/LC
X X X
X X X

XFP/8G/#xxxxxL/SM/LC#Dxx
X
X X X X

XFP/11G/CxxxxL/SM/LC
X
X
X
X
X

XFP/11G/CxxxxV/SM/LC
X
X
X
X

XFP/8G/CxxxxL/SM/LC

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
XFP/10G/850I/MM/LC
XFP/11G/1310S/SM/LC
XFP/11G/1550L/SM/LC
X X X
X X X
X X

X X X

XFP/8G/1310S/SM/LC
XFP/8G/850I/MM/LC
X X X X X X X
X X X X X X X
783 Module and System Specification

WCA-PCN-2G5U
WCC-PC1N-2G7U
2TWCC-PCN-2G7U

4TCA-PCN-4GU+4G
Modules

4TCA-PCN-4GUS+4G
10PCA-PCN-1G3+10G
10TCC-PCN-2G7US+10G
4TCC-PCTN-2G7+10G-LN#DC

10TCC-PCTN-4GUS+10G-V#DL
10TCC-PCTN-4GUS+10G-V#DC
4TCC-PCTN-2G7+10G-V#DC/DL

10TCC-PCTN-4GUS+10G-LN#DC
SFP+CDR/11GU/1310S/SM/LC
SFP+CDR/10GU/1550L/SM/LC
SFPs at the Client Ports

SFP+CDR/10GU/850I/MM/LC
SFP+CDR/11GU/CxxxxL/SM/LC
SFP+CDR/11GU/CxxxxS/SM/LC
SFP+/16GFC/1310S/SM/LC
SFP+/16GFC/850I/MM/LC
Table SFPs at the Client Ports - Part 1:

SFP+/10G/1310S/SM/LC
SFP+/8GU/1310S/SM/LC
SFP+/10G/850I/MM/LC
SFP+/8GU/850I/MM/LC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

SFP/4GU/Dxxxx.xxV/SM/LC#Dxx
SFP/4GU/CxxxxV/SM/LC
SFP/4GU/CxxxxL/SM/LC
SFP/4GU/1310S/SM/LC
SFP/4GU/850I/MM/LC
X X X X X
SFPs

SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx
X
X
X

SFP/2G5U/CxxxxV/SM/LC
X

X
X
X
X
X

SFP/2G5U/CxxxxL/SM/LC
X

X
X
X
X
X

SFP/2G5U/1310S/SM/LC
X X X X X X X X

X
X X X X X X X X
X X X X X X X X

X
X
X
X
X
X X X X
X X X X

SFP/2G5U/1310L/SM/LC
X
X
X

X
X
X
X
X

SFP/HS/1310S/SM/LC
X X

X X
X X

SFP/CL/1310I/SM/LC
SFP/2G1/850I/MM/LC
X

X
X
X

X X X
X X X
X X X
X

SFP/GBE/850I/MM/LC/TIN
SFP/GBE/1310S/SM/LC/TIN
SFP/GBE/1310L/SM/LC/TIN
SFP/GBE/1550V/SM/LC/TIN
X X X X X X X

SFP/GBE/ELECTRICAL/RJ45
X

X X X X X X X X
X
X

SFP/3GSDI/ELECTRICAL/DIN
SFP/3GSDI/ELECTRICAL/HBNC
SFP/FE/C1490U/SM/LC
SFP/FE/C1510U/SM/LC
X X X X X

Appendix A Overview of Modules


Module and System Specification 784

SCU
SCU-II
4WCE-PCN-16GFC
Modules

5TCE-PCN-10GU+10G

10TCE-PCN-10G+100G
5TCE-PCTN-10GU+10G

5TCE-PCTN-8GU+10GS

1. only C band is supported


5TCE-PCN-10GU+AES10G

10TCE-PCN-10G+100G-GF
5TCE-PCTN-10GU+AES10G

5TCE-PCTN-8GU+AES10GS

10TCE-PCN-16GU+AES100G
SFP+CDR/11GU/1310S/SM/LC

X
SFP+CDR/10GU/1550L/SM/LC
SFP+CDR/10GU/850I/MM/LC

X X X
X X X
SFP+CDR/11GU/CxxxxL/SM/LC
SFP+CDR/11GU/CxxxxS/SM/LC
SFP+/16GFC/1310S/SM/LC
SFP+/16GFC/850I/MM/LC
X X X X X

2. only supported for SFP/2G5U/1310S/SM/LC with HW Rev. 2.01


X X X SFP+/10G/1310S/SM/LC
X
X

SFP+/8GU/1310S/SM/LC
X
X

SFP+/10G/850I/MM/LC
X
X
X

SFP+/8GU/850I/MM/LC
X
X X X X

X
X X X X

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx
SFP/4GU/CxxxxV/SM/LC
SFP/4GU/CxxxxL/SM/LC
SFP/4GU/1310S/SM/LC
X
X
X
X

X
X

SFP/4GU/850I/MM/LC
X
X
X
X

X
X
SFPs

SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx
SFP/2G5U/CxxxxV/SM/LC
SFP/2G5U/CxxxxL/SM/LC
SFP/2G5U/1310S/SM/LC
X
X
X
X

X
X

X2
X2

SFP/2G5U/1310L/SM/LC
X
X
X
X

X
X

SFP/HS/1310S/SM/LC
SFP/CL/1310I/SM/LC
SFP/2G1/850I/MM/LC
X X X
X
X X X
X

X
X
X X X
X X X

SFP/GBE/850I/MM/LC/TIN
SFP/GBE/1310S/SM/LC/TIN
SFP/GBE/1310L/SM/LC/TIN
SFP/GBE/1550V/SM/LC/TIN
SFP/GBE/ELECTRICAL/RJ45
SFP/3GSDI/ELECTRICAL/DIN
SFP/3GSDI/ELECTRICAL/HBNC
SFP/FE/C1490U/SM/LC
SFP/FE/C1510U/SM/LC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table SFPs at the Client Ports - Part 2:


Module and System Specification

Modules SFPs

SFP+CDR/11GU/CxxxxS/SM/LC
SFP+/11GU/1310S/SM/LC

SFP/GBE/B1310S/SM/LC
SFP/GBE/B1490S/SM/LC
SFP/GBE/B1310L/SM/LC
SFP/GBE/B1490L/SM/LC
SFP+/11GU/850I/MM/LC
10TCC-PCTN-10G+100GB X X
4TCA-PCN-4GUS+4G X X X X
4WCE-PCN-16GFC X X
5TCE-PCN-10GU+10G X X
5TCE-PCN-10GU+AES10G X X
5TCE-PCTN-10GU+10G X X X X X X
5TCE-PCTN-10GU+AES10G X X X X X X
5TCE-PCTN-8GU+10GS X X X X X X
5TCE-PCTN-8GU+AES10GS X X X X X X

Appendix A Overview of Modules


785
Module and System Specification 786

OSCM-PN
WCA-PCN-2G5U
WCC-PC1N-2G7U
2TWCC-PCN-2G7U

4TCA-PCN-4GU+4G
4TCA-PCN-4GUS+4G

5TCE-PCN-10GU+10G
5TCE-PCN-10GU+AES10G
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx

X
X
SFP/4GU/CxxxxV/SM/LC

X
X
SFP/4GU/CxxxxL/SM/LC

X
X
SFP/4GU/1310S/SM/LC

X
X
SFPs at the Network Ports

X SFP/4GU/850I/MM/LC
X

SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx

X
X
X
X

SFP/2G5U/CxxxxV/SM/LC
X
X
X

SFP/2G5U/CxxxxL/SM/LC
X
X
X

SFP/2G5U/1310S/SM/LC
X
X
X

SFP/2G5U/1310L/SM/LC
X
X
X

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFP/HS/1310S/SM/LC
X
X

SFP/CL/1310I/SM/LC
X
X
SFPs

SFP/2G1/850I/MM/LC
X
X

SFP/HS/850I/MM/LC
X

SFP/GBE/ELECTRICAL/RJ45
X

SFP/3GSDI/#xxxxxV/SM/LC
X

SFP/FE/C1490U/SM/LC
X

SFP/FE/C1510U/SM/LC
X
X

SFP/FE/C1510E/SM/LC
X
X

SFP/FE/C1490V/SM/LC
X
X

SFP/FE/C1510V/SM/LC
X

SFP/FE/D1528.77E/SM/LC
X

SFP/FE/Dxxxxx.xxV/SM/LC
X

SFP+/11GU/CxxxxL/SM/LC
X
X

SFP+/11GU/#19xxxL50/SM/LC
X
X
Appendix A Overview of Modules

CFPs at the Client Ports

CFPs

CFP/103G/SR10/MM/MPO
CFP/112G/LR10R/SM/LC

CFP/112G/LR4/SM/LC
WCC-PCTN-100GA X X
WCC-PCTN-100GB X X X
WCE-PCN-100G X X X
WCE-PCN-100GB X X X

CFPs at the Network Ports


FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

CFPs
CFP/4x28G/#19xxx-#19xxxL/SM/LC

CFP/4x28G/#DCTL/SM/LC
CFP/112G/LR10R/SM/LC

WCE-PCN-100G X X
WCE-PCN-100GB X X
10TCE-PCN-10G+100G-GF X X X
10TCE-PCN-10G+100G X X X
10TCE-PCN-16GU+AES100G X X X

Module and System Specification 787


788
Module and System Specification
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Appendix B

Use of DCM with Doublestage


EDFA
The midstage access of doublestage EDFAs allows you to insert a dispersion
compensation module without affecting the line budget.
The maximum per channel input power into a DCM is limited to 0 dBm to avoid
non-linear effects. The output power at the midstage port of a doublestage
EDFA may violate this limit if the input power at low channel counts is high.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Table 1344 and Table 1345 provide maximum per channel input power values
of the fixed gain-controlled EDFAs. These are listed according to channel count
and DCM type.

Table 1344: EDFA-C-D17-GC - max. EDFA Input Power per Channel


Max. number Without
DCM-20 DCM-40 DCM-80
of channels DCM
4 -14 dBm -14.5 dBm -16 dBm -19 dBm
8 -17 dBm -17 dBm -17 dBm -19 dBm
16 -20 dBm -20 dBm -20 dBm -20 dBm
32 -23 dBm -23 dBm -23 dBm -23 dBm
40 -24 dBm -24 dBm -24 dBm -24 dBm

Table 1345: EDFA-L-D17-GC - max. EDFA Input Power per Channel


Max. number Without
DCM-20 DCM-40 DCM-80
of channels DCM
4 -14 dBm -14 dBm -15.5 dBm -18.5 dBm
8 -17 dBm -17 dBm -17 dBm -18.5 dBm
16 -20 dBm -20 dBm -20 dBm -20 dBm
32 -23 dBm -23 dBm -23 dBm -23 dBm
40 -24 dBm -24 dBm -24 dBm -24 dBm

Module and System Specification 789


790
Module and System Specification
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Appendix C

History of Changes
This appendix lists significant changes (additions, corrections, etc.) made in the
separate issues of this documentation. They reflect all subreleases of the
product releases 9.3, 10.1, 10.2, 10.3, 11.1, 11.2, 12.1, 12.2, and 12.3.
Significant changes made to a MSS document of the product releases 7.0, 7.1,
8.1, 8.1.1, 8.2, 8.3, 9.1, and 9.2 can be found in a former version of the FSP
3000R7 Module and System Specification.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Releases 8.1.1 through 9.2


Prod. Document Issue
Description
Rel. Version Date
9.3 Issue A March 2010 • dimensions of all shelves revised
• SH1HU-HP/2DC: Electrical Specifications revised
• SFP/2G1/850I/MM/LC: Max. link distance revised
• The following shelves, modules and pluggable transceivers
removed due to discontinuation: 
SH1HU/2DC, SH1HU-P/DCM, WCC-PC-10G-U#Dxx,
WCC-PC-10G-V#Dxx, WCC-PC-10G-V#Cxxxx,
4TCC-PC-2G7+10G-V#Dxx, 4TCC-PC-2G7+10G-V#Cxxxx,
10TCC-PC-4GU+10G-V#Dxx, 10TCC-PC-4GU+10G-V#Cxxxx,
WCC-PC-2G7U-R#Dxx, WCC-PC-2G7U-V#Cxxxx,
4TCA-PC-4GU+4G-V#Dxx, 4TCA-PC-4GU+4G-V#Cxxxx,
4TCA-PC-4GU+4G-L#Cxxxx, 4TCA-LS+1G3-V#Dxx (L band
only), WCE-LS-T-V#Dxx, WCE-LS-T-V#Cxxxx,
8TCE-ESCON+2G5-V#Dxx 
(L band only), 8TCE-GLINK+2G5-V#Dxx (L band only),
SFP/2G5U/Dxxxx.xxV/SM/LC#Dxx, SFP/HS/850I/MM/LC,
SFP/FE/C1510E/SM/LC, 2BSM-#D33-#D64, 4GSM-#D33-#D48,
4GSM-#D49-#D64, 8GSM-#D33-#D64, 1GSM+#Dxx-#Dyy (L
Band only, 4CSM-#Dxx-#Dyy (L Band only), 4CSM+#Dxx-#Dyy (L
Band only), 1CSM+#Dxx-E/W (L Band only), EDFA-L-S10

Module and System Specification 791


Prod. Document Issue
Description
Rel. Version Date
9.3 Issue A March 2010 • Following modules and components added in Release 9.3:
40CSM-OJG/3HU-R#C, 40CSM-OJG/3HU-F/2DC#C-ODD,
40CSM-OJG/3HU-R#C-ODD, 10TCC-PCTN-4GUS+10G,
4TCA-PCN-4GUS+4G, 5TCE-PCTN-10GU+10G,
XFP/11G/DCTV/SM/LC, SFP+/10G/1310S/SM/LC,
SFP+/8GU/1310S/SM/LC, SFP+/10G/850I/MM/LC,
SFP+/8GU/850I/MM/LC, 5GSM-#19590-#19200,
8CSM-#19xxx-#19yyy, 2-OTFM+#1650, OTDR
• 4TCC-PCTN-10G+40G-L#DC and 2TWCC-PCN-2G7U revised
• OSCM-PN, OSCM-V#1630 and 2OSCM-V#1630: Max. number of
OSC modules per node corrected
• 8ROADM-C40/0/OPM: block diagram corrected
• WCC-PCTN-10G: table of Performance Monitoring Client Inter-
face - Egress Direction for all Variants added
• 4TCA-PCN-4GU+4G: System Performance table revised
• XFP/8G/Dxxxx.xxL/SM/LC renamed to XFP/8G/#xxxxxL/SM/LC
• XFP/8G/1310S/SM/LC: Min. extinction ratio revised
• 40CSM/2HU-#xxxxx-#yyyyy, 1CSM+#19xxx-E/W,
XFP/11G/#xxxxxV/SM/LC#Dxx, XFP/8G/#xxxxxL/SM/LC#Dxx,

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFP/4GU/#xxxxxV/SM/LC#Dxx, SFP/2G5U/#xxxxxU/SM/LC#Dxx:
channel numbering changed to frequency based naming
• 4TCC-PCTN-10G+40G-L#DC: number of back-to-back cascades
added
• channel modules and pluggable transceivers: Maximum DGD and
Maximum PMD deleted and OSNR PMD penalty revised
• EDFA-C-D17-GC and EDFA-L-D17-GC: Max. optical output power
revised
• 4TCC-PCTN-2G7+10G-LN#DC, WCC-PCTN-10G-LN#DC,
10TCC-PCTN-4GU+10G-LN#DC and
10TCC-PCTN-4GUS+10G-LN#DC: Min. extinction ratio revised
• DCG-M/xxx/TWRS: Optical Characteristics revised
Issue B May 2010 • Sections of “Power Consumption” and “Interoperability of Channel
Modules” added to Chapter 1: Introduction
• SFP+/8GU/1310S/SM/LC, SFP+/8GU/850I/MM/LC: Bit error ratio
corrected
• SFP+/8GU/850I/MM/LC: Receiver dynamic range revised
• ROADM-C40/40/OPM-3HU/2DC, ROADM-C80/0/OPM,
8ROADM-C40/0/OPM, 8ROADM-C40/0/OPM: Optical Character-
istics - General revised
• 1PM/MM, 2PM/MM: Optical return loss deleted and Directivity
revised
• 2WCA-PCN-10G, WCA-PC-10G-V: Latency per pair revised

792 Module and System Specification


Appendix C History of Changes

Prod. Document Issue


Description
Rel. Version Date
9.3 Issue B May 2010 • EDFA-C-S20-GCB, EDFA-C-D20-VGC, EDFA-C-D20-GC,
EDFA-C-S20-GCB-DM, EDFA-C-D20-VGC-DM,
EDFA-C-D20-VLGC-DM: Latency revised
• Typ. power consumption added to following modules:
10TCC-PCTN-4GU+10G, 2TWCC-PCN-2G7U,
4TCC-PCN-2G1U+2G5, 4TCC-PCTN-10G+40G,
4TCC-PCTN-10G+40G, 4TCC-PCTN-2G7+10G,
WCC-PC1N-2G7, WCC-TN-40G-L#DC, 10PCA-PCN-1G3+10G,
2TCA-PCN-1G3+2G5, 2TCA-PCN-622M+2G5, 2WCA-PCN-10G,
4TCA-PCN-4GU+4G, WCA-PC-10G-V, WCA-PCN-2G5U,
8TCE-ESCON+2G5, 8TCE-GLINK+2G5,
5TCE-PCTN-10GU+10G, EDFA-C-S10, EDFA-C-D17-GC,
EDFA-L-D17-GC, EDFA-C-D20-GC, EDFA-C-D20-VGC,
EDFA-C-D20-VGC-DM, EDFA-C-S18-GC, EDFA-C-S18-GCB,
EDFA-C-S20-GCB, EDFA-C-S20-GCB-DM,
EDFA-C-D20-VLGC-DM
• 5TCE-PCTN-10GU+10G: Max. latency per pair revised
• 2WCA-PCN-10G: Number of regenerators revised
• 40CSM/2HU-#Dxx-#Dyy, 1CSM+#Dxx-E/W,
XFP/11G/Dxxxx.xxV/SM/LC#Dxx,
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx,
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx: frequency based naming


rolled back to channel numbering
Issue C May 2010 • WCA-PC-10G-V, WCA-PCN-2G5U: Latency per pair corrected
• XFP/11G/DCTV/SM/LC: Technical Data revised
• 5GSM-#19590-#19200: MTBF at 25°C ambient temperature
revised
• RAMAN-C10: Back reflection set range revised
• PSU/7HU-AC, PSU/7HU-AC-HP, PSU/1HU-R-AC: Table “Power
Cords” added and Table “Electrical Specifications” revised
Issue D July 2010 • 8ROADM-C40/0/OPM: description revised
• WCA-PC-10G-V revised
• SFP/FE/C1490U/SM/LC and SFP/FE/C1510U/SM/LC: OPR mea-
surement range revised
• SFP/2G5U/1310S/SM/LC (HW Rev. 1.01): Receiver dynamic
range at GbE and OPR measurement range revised
• SFP/2G5U/1310S/SM/LC (HW Rev. 1.02): OPR measurement
range revised
• EDFA-C-S20-GCB-DM: Latency for HW 3.01 added
• RAMAN-C10: Latency values revised
• SFP/FE/D1528.77E/SM/LC: Receiver dynamic range changed to 
-42 dBm ... -10 dBm (BER < 10-7)

Module and System Specification 793


Prod. Document Issue
Description
Rel. Version Date
9.3 Issue D July 2010 • 5TCE-PCTN-10GU+10G: Table “System Performance for all Vari-
ants” revised
• SFP/2G1/850I/MM/LC: value added for “Receiver dynamic range
at 2.5 Gbit/s data rate with 8B/10B coding when used in
WCA-PCN-2G5 in adaptive odd rate mode”, Receiver dynamic
range at GbE and OPR measurement range revised
• SH1HU-F/2DC, SH1HU-HP/2DC, SH1HU-R, SH7HU and SH9HU:
“Max weight all slots fully populated” added
• Fault and Performance Monitoring tables of all EDFAs revised
• PSU/1HU-R-AC: specification for “Depth” added
• 10TCC-PCTN-4GUS+10G: Latency values added
• SFP/4GU/CxxxxL/SM/LC: “Receiver dynamic range”, “Max. dis-
persion load” and “OPR measurement range” revised
Issue E August • DCG-M/xxx/SSMF: weight changed from 520 g into 550 g and val-
2010 ues of “Chromatic Dispersion” added
• 2TWCC-PCN-2G7U: “System Performance” revised
• 10PCA-PCN-1G3+10G: support of XFP/10G/1310S/SM/LC
removed
• XFP/11G/Dxxxx.xxV/SM/LC#Dxx: specifications revised

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• 2WCA-PCN-10G: “Latency per pair” revised
• 8ROADM-C40/0/OPM: value of “N-D Input total power” revised
• 4TCA-PCN-4GUS+4G: “Operation Modes” revised
• WCC-PCTN-10G-LN#DC: “Bit Error Rate Versus OSNR” revised
• WCC-PCTN-10G, 4TCC-PCTN-2G7+10G,
10TCC-PCTN-4GU+10G, 10TCC-PCTN-4GUS+10G,
5TCE-PCTN-10GU+10G, XFP/11G/DCTV/SM/LC, and
SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx: “Optimum dispersion load
range”, “Dispersion load range with 1 dB OSNR penalty” and Dis-
persion load range with 2 dB OSNR penalty” added and “Min. dis-
persion load”, Max. dispersion load” and “Optimum dispersion
load” deleted.
• DCG-M/xxx/TWRS: values of “Chromatic Dispersion” added
10.1 Issue A September • 4TCA-PCN-4GU+4G and 4TCA-PCN-4GUS+4G: Client Channel
2010 Card Protection added to “Protection scheme” and
SFP/GBE/ELECTRICAL/RJ45 added to Table of “Supported Cli-
ent SFPs”
• 5TCE-PCTN-10GU+10G: Tables of “Fault Monitoring - General for
all Variants”, “Performance Monitoring Client Interface - Ingress
Direction for all Variants”, “Performance Monitoring Network Inter-
face - Egress Direction for all Variants” and “Protection Switching
for all Variants” updated
• 8ROADM-C80/0/OPM, 2PCA-PCN-10G, EDFA-C-D27-GCB-DM
and DCG50-M/xxx/SSMF added

794 Module and System Specification


Appendix C History of Changes

Prod. Document Issue


Description
Rel. Version Date
10.1 Issue A September • 10TCC-PC-4GU+10G and 10TCC-PCTN-4GUS+10G: 
2010 table of “Performance Monitoring Client Interface - Ingress Direc-
tion for all Variants” updated, SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx
and SFP/GBE/ELECTRICAL/RJ45 added to Table of “Supported
Client SFPs”, “Number of back-to-back cascades” revised
• 2TWCC-PCN-2G7U: SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx,
SFP-OJDE/GBE/1310S/SM/LC and
SFP-OJDE/GBE/CxxxxV/SM/LC added to Table of “Supported Cli-
ent SFPs”
• WCC-PCTN-10G: XFP/11G/Dxxxx.xxV/SM/LC#Dxx and
XFP/11G/Dxxxx.xxV/SM/LC#Dxx added to Table of “Supported
Client SFPs”
• 4TCC-PCTN-2G7+10G: SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx
added to Table of “Supported Client SFPs”
• EDFA-C-S18-GC, EDFA-C-S20-GCB, EDFA-C-D20-VGC,
EDFA-C-D20-VLGC-DM, EDFA-C-D27-GCB-DM: Update of Per-
formance Monitoring tables
• SFP/FE/C1490U/SM/LC, SFP/FE/C1510U/SM/LC,
SFP/FE/C1490V/SM/LC and SFP/FE/C1510V/SM/LC: “Max. link
distance single-mode fiber (SMF-28)” revised
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

• NCU and NCU-II: Table “Communication Channels” added


• RSM-OLM: specification revised
• SFP/2G5U/1310S/SM/LC (HW Rev. 2.01): added to the specifica-
tions of the pluggable transceivers and to the “Supported SFPs” of
the SCU
• SFP+/10G/1310S/SM/LC: value for “MTBF at 25°C ambient tem-
perature” added
Issue B September • 8ROADM-C80/0/OPM: value for “MTBF at 25°C ambient tempera-
2010 ture” added
• EDFA-C-D27-GCB-DM: “Maximum total input power” revised
• Chapter 1: Introduction revised
• 2WCA-PCN-10G and WCA-PCN-2G5U: “Number of regenerators”
revised
• SCU: “Fiber types” and “Max. link distance” revised
• XFP/8G/#xxxxxL/SM/LC: specification revised
• DCG50-M/xxx/SSMF: “Weight” revised
• SFP+/10G/850I/MM/LC and SFP+/10G/1310S/SM/LC: 5.0 Gbit/s
added to “Data rates”
Issue C September • XFP/8G/#xxxxxL/SM/LC: specification revised
2010
• 4TCA-PCN-4GUS+4G: Add/Drop multiplexer operation mode
revised

Module and System Specification 795


Prod. Document Issue
Description
Rel. Version Date
10.1 Issue D September • SCU: “Max. link distance” revised
2010
• NCU and NCU-II: table “Communication Channels” revised
• 4TCC-PCN-2G1U+2G5: “Switching criteria” revised
Issue E January • EDFA-C-D27-GCB-DM: “Insertion loss N-R to U-T” added and
2011 “Environmental conditions” revised
• WCA-PCN-2G5U: “System Performance” revised
• 40CSM-OJG/3HU-F/2DC#C, 40CSM-OJG/3HU-F/2DC#C-ODD,
40CSM-OJG/3HU-R#C and 40CSM-OJG/3HU-R#C-ODD
removed temporarily due to a stop ship on these modules
• SFP/FE/C1490V/SM/LC and SFP/FE/C1510V/SM/LC: “OPR mea-
surement range” revised
• WCC-PCTN-10G: table “System Performance for all Variants”
revised
• WCC-TN-40G-L#DC and 4TCC-PCTN-10G+40G-L#DC: table
“System Performance” revised
• 2PCA-PCN-10G: XFP/11G/DCTV/SM/LC added to tables “Sup-
ported Client XFPs” and “Supported Network Interfaces”
• 4TCA-PCN-4GU+4G: Operation Modes revised
• 10PCA-PCN-1G3+10G: XFP/11G/DCTV/SM/LC added to table

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
“Supported Network XFPs”
• Latency specifications added to all XFPs
• Preface revised
• 2WCA-PCN-10G: XFP/8G/850I/MM/LC and
XFP/8G/1310S/SM/LC added to “Supported Client XFPs”
• CCM-C40/8: specification revised
Issue F April 2012 • 40CSM/P-2HU#19590-#19200-DM: “Weight” revised
• EDFA-C-D20-VGC, EDFA-C-D20-VGC-DM,
EDFA-C-D20-VLGC-DM, EDFA-C-D27-GCB-DM,
EDFA-C-S20-GCB, EDFA-C-S20-GCB-DM: OPR/OPT accuracy
added
• XFP/11G/DCTV/SM/LC, XFP/11G/Dxxxx.xxV/SM/LC#Dxx,
XFP/8G/#xxxxxL/SM/LC#Dxx, XFP/11G/CxxxxV/SM/LC,
XFP/11G/1550L/SM/LC: Min. extinction ratio revised
• 4TCA-PCN-4GUS+4G: “Operation Modes” revised
• NCU-II, NCU, UTM, OSCM-PN, OSCM-V#1630 and
2OSCM-V#1630: Max. link distance added to table “Ethernet Inter-
face”
• Table “Channel Module Error Signaling on Client Port” added to
Appendix A
• 10PCA-PCN-1G3-10G: “Supported Client SFPs” updated
• 10TCC-PCTN-4GUS+10G: “Restoration time” updated

796 Module and System Specification


Appendix C History of Changes

Prod. Document Issue


Description
Rel. Version Date
10.1 Issue F April 2012 • XFP/10G/850I/MM/LC: “Receiver dynamic range” revised. The
stated sensitivity is acc. to IEEE and ANSI standard now.
• 5TCE-PCTN-10GU+10G: “Number of regenerators” revised
10.2 Issue A October • CCM-C80/8: specification added
2010
• 40CSM-C80/2HU-#19xxx-#19yyy added
• section “Right to Use Versions” added to the “Introduction”
Issue B December • 2WCC-PCN-10G, 40CSM/P-2HU#19590-#19200-DM,
2010 5GSM/P-#19590-#19200-DM, 8CSM/P-#19xxx-#19yyy,
DCG50-M/xxx/TWRS, SFP/GBE/1310S/SM/LC/TIN,
SFP/GBE/1310L/SM/LC/TIN, SFP/GBE/1550V/SM/LC/TIN and
SFP/GBE/850I/MM/LC/TIN: specifications added
• 4TCA-PCN-4GU+4G: following transceiver added to table “Sup-
ported Client SFPs”: SFP/GBE/1310S/SM/LC/TIN,
SFP/GBE/1310L/SM/LC/TIN, SFP/GBE/1550V/SM/LC/TIN and
SFP/GBE/850I/MM/LC/TIN
• XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev. 3.01) added
Issue C March 2011 • The following shelves and modules removed due to discontinua-
tion: WCC-PCTN-10G-V#D01-32,
4TCC-PCTN-2G7+10G-V#D01-32,
10TCC-PCTN-4GU+10G-V#D01-32,
8TCA-PC-2G1U+10G-V#Dxx (L-Band), 8TCE-GLINK+2G5-V,
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

8TCE-ESCON+2G5-V#Cxxxx, NCU-A, NCU-B, NCU-GDPS,


SH1HU/PASSIVE, SH1HU/FIBERMANAGEMENT,
40CSM-#Dxx-#Dyy, 3BSM-#G1310-#C1610-E/W,
EDFA-C-S18-GC, EDFA-C-D20-GC, EDFA-C-S18-GCB
• section “Right to Use Versions” in “Introduction” revised
• 5TCE-PCTN-10GU-LN#DC: “Network Port - Optical Performance”
revised
• 2PCA-PCN-10G and 10PCA-PCN-1G3+10G: table “Connectivity
Fault Management / Ethernet OAM” and table “Protection Switch-
ing“ added
• XFP/11G/Dxxxx.xxV/SM/LC#Dxx HW Rev 4.01 and 5.01 added
and HW Rev 3.01 removed
• NCU-II: table “Communication Channels” revised
• EDFA-C-D27-GCB-DM: optical specification revised
• 2WCC-PCN-10G, 4TCC-PCTN-2G7+10G,
10TCC-PCTN-4GU+10G and 10TCC-PCTN-4GUS+10G: “Num-
ber of regenerators” revised

Module and System Specification 797


Prod. Document Issue
Description
Rel. Version Date
10.2 Issue C March 2011 The following was already corrected in the MSS 10.1 Issue E:
• EDFA-C-D27-GCB-DM: “Insertion loss N-R to U-T” added and
“Environmental conditions” revised
• WCA-PCN-2G5U: “System Performance” revised
• 40CSM-OJG/3HU-F/2DC#C, 40CSM-OJG/3HU-F/2DC#C-ODD,
40CSM-OJG/3HU-R#C and 40CSM-OJG/3HU-R#C-ODD
removed temporarily due to a stop ship on these modules
• SFP/FE/C1490V/SM/LC and SFP/FE/C1510V/SM/LC: “OPR mea-
surement range” revised
• WCC-PCTN-10G: table “System Performance for all Variants”
revised
• WCC-TN-40G-L#DC and 4TCC-PCTN-10G+40G-L#DC: table
“System Performance” revised
• 2PCA-PCN-10G: XFP/11G/DCTV/SM/LC added to tables “Sup-
ported Client XFPs” and “Supported Network Interfaces”
• 4TCA-PCN-4GU+4G: Operation Modes revised
• 10PCA-PCN-1G3+10G: XFP/11G/DCTV/SM/LC added to table
“Supported Network XFPs”
• Latency specifications added to all XFPs

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• Preface revised
• 2WCA-PCN-10G: XFP/8G/850I/MM/LC and
XFP/8G/1310S/SM/LC added to “Supported Client XFPs”
• CCM-C40/8: specification revised
Issue D April 2011 • OSCM-PN, OSCM-V#1630 and 2OSCM-V#1630: “Max. number of
OSC modules per node” revised
• SFP/4GU/CxxxxV/SM/LC (HW Rev. 3.01): specification added
10.3 Issue A May 2011 • SH1HU-R/PF, FAN/1HU, PSU/1HU-R-AC-200,
EDFA-C-S26-VGC-DM, 5TCE-PCTN-10GU+AES10G,
XFP/11G/DCTLNR/SM/LC, SH7HU-R, PSU/7HU-R-DC,
PSU/7HU-R-DC-HP, 40CSM/2HU-#19590-#19200 and
40CSM-FL/2HU-#19590-#19200, 2RAMAN-C15-LL: specifica-
tions added
• 10TCC-PCTN-4GUS+10G and 10TCC-PC-4GU+10G:
SFP-OJDE/GBE/1310S/SM/LC and
SFP-OJDE/GBE/CxxxxV/SM/LC added to the “Supported Client
SFPs”
• 5TCE-PCTN-10GU+10G: 5G IB added to tables ”Client Ports -
Specifications for all Variants”, Operation Modes for all Variants,
System Performance for all Variants” added
• 2PCA-PCN-10G, 10PCA-PCN-1G3-10G and
4TCA-PCN-4GU+4G: “Operation Modes” revised
• Optical Amplifiers: value for “Polarization mode dispersion”
removed

798 Module and System Specification


Appendix C History of Changes

Prod. Document Issue


Description
Rel. Version Date
10.3 Issue A May 2011 • Table for “Optical Line Monitoring Support”, “Channel Module
In-band Management Support” and “Loop Functionality Support”
added to Appendix A: Overview of Modules
• 2WCC-PCN-10G, NCU, NCU-II, OSCM-PN, OSCM-V#1630 and
2OSCM-V#1630: specifications revised
• XFP/11G/CxxxxV/SM/LC and XFP/11G/CxxxxL/SM/LC: Latency
revised
• 8CSM/P-#C1470-#C1610-DM, 8CSM/P+#C1470-#C1610-DM,
8CSM/P-#C1270-#C1450, 1PM/SM, 2PM/SM,
2BSM/P-#C1270-#C1610-DM, 5GSM/P-#19590-#19200-DM,
5PSM, 8CSM-#19xxx-#19yyy, 8CSM/P-#19xxx-#19yyy,
ILM50-#DC, DCF-M/xxx/SSMF: typical values for “Insertion loss”
added
• ROADM-C40/40/OPM-3HU/2DC, ROADM-C80/0/OPM,
8ROADM-C40/0/OPM, 8ROADM-C80/0/OPM, CCM-C40/8 and
CCM-C80/8: Latency values added
Issue B July 2011 • SH7HU-R: PSU/7HU-AC-HP added as supported power supply
• 10TCC-PCTN-4GUS+10G, 2TWCC-PCN-2G7U and
2WCC-PCN-10G: footnote added to supported client transceivers
• FAN/1HU: “MTBF at 25°C ambient temperature” added
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

• 8CSM/P+#C1470-#C1610-DM and 8CSM/P-#C1270-#C1450:


“Insertion loss” revised
• “Max. latency per pair” changed into “Max. module delay”
• 2WCC-PCN-10G and 10TCC-PCTN-4GUS+10G: “Max. Module
Delay” revised
• EDFA-C-S26-VGC-DM, RAMAN-C10 and 2RAMAN-C15-LL:
“OPR/OPT accuracy” added
Issue C October • 10TCC-PCTN-4GU+10G: footnote added to supported client
2011 transceivers
• “Interoperability of Channel Modules" revised
• 5PSM: latency revised
• FAN/9HU, CEM/9HU, FAN/Plug-In, SH1HU-HP/2DC,
SH1HU-F/2DC, SH1HU-R, FAN/1HU, EDFA-C-S26-VGC-DM,
ROADM-C80/0/OPM, 8ROADM-C40/0/OPM, CCM-C40/8,
CCM-C80/8, 4-OPCM, 10TCC-PCTN-4GUS+10G,
8TCA-PC-2G1U+10G, 4TCA-LS+1G3, PSCU, NCU, NCU-II,
UTM, VSM, RSM-OLM#1630, OSCM-V#1630, 2OSCM-V#1630
and OSCM-PN, SCU, SCU-S, RSM-SF#1310, RSM-SF#1510:
“Typ. power consumption” added
• 2RAMAN-C15-LL: specification revised
• RSM-SF#1310 and RSM-SF#1510: “Pilot receiver wavelength
range” revised

Module and System Specification 799


Prod. Document Issue
Description
Rel. Version Date
10.3 Issue C October • 5TCE-PCTN-10GU+AES10G: F2488 and F9953 added as sup-
2011 ported protocols
• PSM-95/5: footnote added to “Optical Interfaces”
• WCC-PCTN-10G, 2PCA-PCN-10G and 10PCA-PCN-1G3+10G:
“Number of regenerators” revised
• Optical filter modules, RAMAN-C10, 2RAMAN-C15-LL,
ROADM-C40/40/OPM-3HU/2DC, ROADM-C80/0/OPM,
8ROADM-C40/0/OPM and 8ROADM-C80/0/OPM: “Passband
width” revised
• 10PCA-PCN-1G3+10G: “Average latency” revised
11.1 Issue A March 2012 • 5TCE-PCTN-10GU+10G and 5TCE-PCTN-10GU+AES10G:
o
added footnote to table “Fault Monitoring Client Interface -
Ingress Direction for all Variants“ and “Performance
Monitoring Client Interface - Ingress Direction for all Variants”
o
revised table “System Performance for all Variants”
o
revised “Number of regenerators”, “Max. frame size for FC
services” and “Typ. power consumption”
• 2WCC-PCN-10G and 2RAMAN-C15-LL: specifications revised
• SH9HU and PSU/7HU-AC-HP: “General Information” revised

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• Chapter 1, Introduction revised
• XFP/11G/DCTV/SM/LC, XFP/11G/DCTLNR/SM/LC,
XFP/11G/Dxxxx.xxV/SM/LC#Dxx: “OSNR penalty” revised
• XFP/11G/DCTLNR/SM/LC: “OPR measurement range” revised
• EDFA-C-S26-VGC-DM: “Max. OSC pilot input signal” added
• XFP/10G/850I/MM/LC: added HW Rev. 2.01
• PSU/7HU-AC-800, DCF1HU-P/x/MCOR, 2PSM-95/5,
10TCC-PCN-2G7US+10G, 5TCE-PCTN-8GU+10GS, ,
XFP/11G/DCTLN/SM/LC, XFP/10G/850I/MM/LC (HW Rev. 2.01):
specifications added
• WCC-PCTN-10G, 4TCC-PCTN-2G7+10G,
10TCC-PCTN-4GU+10G and 10TCC-PCTN-4GUS+10G: OPT
support on network ports added
• Appendix A, section “Channel Module Protection Support”
renamed into “Channel Module Protection Capabilities” and
revised, “ROADM Supported Channel Modules” and “ROADM
Supported Pluggable Transceivers” added
• “Required RAM consumption on NCU” for all modules revised
• SFP+/10G/1310S/SM/LC, SFP+/10G/850I/MM/LC,
SFP+/8GU/1310S/SM/LC and SFP+/8GU/850I/MM/LC: “OPR
measurement range” revised

800 Module and System Specification


Appendix C History of Changes

Prod. Document Issue


Description
Rel. Version Date
11.1 Issue B April 2012 • WCC-PCTN-100GA, CFP/112G/LR10R/SM/LC,
CFP/112G/LR4/SM/LC, XFP/OTN11G/#19xxxV/SM/LC,
XFP/8G/CxxxxL/SM/LC, 5TCE-PCTN-8GU+AES10GS: specifica-
tions added
• XFP/11G/DCTLN/SM/LC: specification revised
• 2-OTFM+#1650: specification revised
• 5TCE-PCTN-8GU+10GS: “Performance Monitoring Network Inter-
face - General for all Variants” revised
• 2PCA-PCN-10G and 10PCA-PCN-1G3-10G: LAG protection
added
• 5TCE-PCTN-10GU+AES10G: “Number of regenerators” revised
Issue B April 2012 The following was already corrected in the MSS 10.1 Issue F:
• 5TCE-PCTN-10GU+10G: “Number of regenerators” revised
Issue C June 2012 • WCC-PCTN-100GA: “Environmental conditions” revised and
“Max. module delay” added
• XFP/11G/DCTLN/SM/LC: Extinction ratio revised
• ROADM-C80/0/OPM: “Optical Characteristics - Network Port”
revised
• following modules removed due to discontinuation:
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

XFP/10G/1310S/SM/LC, XFP/10G/1550L/SM/LC,
XFP/10G-2R/1310S/SM/LC, XFP/10G-2R/850I/MM/LC,
WCA-PC-10G, 8TCA-PC-2G1U+10G, 4TCA-LS+1G3,
8TCE-ESCON+2G5, ROADM-C40/40/OPM-3HU/2DC,
EDFA-C-S10
11.2 Issue A September • SCU-II, NCU-II-P, AMP-S20H-C15, AMP-S20L-C15,
2012 9ROADM-C96/0/OPM, 96CSM/4HU-#19600-#19125 specifica-
tions added
• WCC-PCTN-100GA: added OTU4 support to client interface and
“Receiver dynamic range” of the network port revised, value for
“Module delay” updated
• VSM: “Wavelength range” revised
• “Wavelength stability (operating)” added to following modules:
WCC-TN-40G-L#DC, 4TCC-PCTN-10G+40G-L#DC,
WCC-PCTN-100GA, WCC-PCTN-10G, 4TCC-PCTN-2G7+10G,
10TCC-PCTN-4GU+10G, 10TCC-PCTN-4GUS+10G,
5TCE-PCTN-10GU+10G, 5TCE-PCTN-10GU+AES10G,
5TCE-PCTN-8GU+10GS, 5TCE-PCTN-8GU+AES10GS,
XFP/11G/DCTV/SM/LC, XFP/11G/DCTLNR/SM/LC,
XFP/11G/DCTLN/SM/LC, XFP/11G/Dxxxx.xxV/SM/LC#Dxx,
XFP/OTN11G/#19xxxV/SM/LC, XFP/8G/#xxxxxL/SM/LC#Dxx,
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx,
SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx

Module and System Specification 801


Prod. Document Issue
Description
Rel. Version Date
11.2 Issue A September • “Required RAM consumption” revised for every module
2012
• added Path Protection to table “Channel Module Protection Capa-
bilities” in the Appendix A.
• Support of “ITU-T G.8262 and IEEE 1588v2 compliant transparent
Ethernet transport” added to 4TCA-PCN-4GU+4G,
WCC-PCTN-10G and 2WCC-PCN-10G
• Chapter “Introduction”: Section “Module Delay” revised and sec-
tion “Latency” added
• “Number of regenerators” revised of following modules: 
2PCA-PCN-10G, 10PCA-PCN-1G3-10G,
10TCC-PCN-2G7US+10G, 10TCC-PCTN-4GU+10G,
10TCC-PCTN-4GUS+10G, 4TCC-PCTN-2G7+10G,
WCC-PCTN-10G, 5TCE-PCTN-8GU+10GS,
5TCE-PCTN-8GU+AES10GS
Issue B January • SFP+CDR/10GU/850I/MM/LC, SFP+CDR/11GU/1310S/SM/LC,
2013 SFP+CDR/10GU/1550L/SM/LC, SFP+/16GFC/850I/MM/LC,
SFP+/16GFC/1310S/SM/LC,
CFP/4x28G/#19xxx-#19xxxL/SM/LC,
XFP/16GFC/#xxxxxL/SM/LC#Dxx, 4WCE-PCN-16GFC,
10TCE-PCN-10G+100G-GF, 10TCE-PCN-10G+100G specifica-
tions added

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• 10TCC-PCN-2G7US+10G: “Slot positions” revised
• CFP/112G/LR10R/SM/LC: Transmitter output power range, each
lane changed
• App A: Table “ROADM compatible Channel Modules an Amplifi-
ers” completed
• assignment of NCU and SCU type modules to the A and B slots for
the SH1HU-R/PF shelf corrected
• defined the environmental conditions for all 5TCE modules more
precisely
Issue C May 2013 General (concerns some parts of the MSS)
• corrected the modules' slot positions for the 7HU shelf types
• updated RAM consumption values for modules acc. to Rel. 11.2.3
Chapter 3
• 10TCC-PCN-2G7US+10G:
o max. frame size value added
o module delay values corrected
• 10TCC-PCTN-4GU+10G: added footnote for 1310nm and CWDM
SFP-OJDE to table 212 "Supported Client SFPs"
• 10TCC-PCTN-4GUS+10G: added footnote for 1310nm and
CWDM SFP-OJDE to table 239 "Supported Client SFPs"
• WCC-PCTN-100GA: Receiver wavelength range in table 142
"Network port" corrected

802 Module and System Specification


Appendix C History of Changes

Prod. Document Issue


Description
Rel. Version Date
11.2 Issue C May 2013 Chapter 4
• 2WCA-PCN-10G:
o client plugs in table 406 corrected.
o grey and CWDM 8G SFPs removed from network interface
• WCA-PCN-2G5:
o
footnote to SFP/3GSDI/ transceivers added
• 4TCA-PCN-4GU+4G:
o
added footnote for 1310nm and CWDM SFP-OJDE to table
"Supported Client SFPs"
• 4TCA-PCN-4GUS+4G:
o
added footnote for 1310nm and CWDM SFP-OJDE to table
"Supported Client SFPs"
• WCC-PCTN-100GA:
o typ. and max, power consumption values for HW rev. 1.02
added
o added module delay value for the OTU4 rate in table 145
Chapter 5
• 5TCE-PCTN-10GU+AES10G
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

o
data rate of 10.7092 Gbit/s for F9953 added to table 567
• 10TCE-PCN-10G+100G:
o
Module delay values in table “System Performance” changed
o
Naming SFP+CDR devices in Table "Supported SFP/SFP+
Client Transceiver Types" corrected
• 10TCE-PCN-10G+100G-GF:
o added max. frame size for 10GbE services to Table "System
Performance"
o Naming SFP+CDR devices in Table "Supported SFP/SFP+
Client Transceiver Types" corrected
• 4WCE-PCN-16GFC: Footnote added to table "Supported Client
SFP+ Types" - (SFP+/10G/850I/MM/LC and
SFP+/10G/1310S/SM/LC for 10GbE only)
• WCE-PCN-100G added
Chapter 6
• CFP/4x28G/#19xxx-#19xxxL/SM/LC: using in a 100 GHz grid filter
system added
• SFP/FE/Dxxxxx.xxV/SM/LC, SFP/3GSDI/#xxxxxV/SM/LC,
SFP/3GSDI/ELECTRICAL/DIN, SFP/3GSDI/ELECTRI-
CAL/HBNC: added
• SFP+CDR/10GU/850I/MM/LC: data rate of 10.5 Gbit/s removed

Module and System Specification 803


Prod. Document Issue
Description
Rel. Version Date
11.2 Issue C May 20013 Chapter 7
• OSCM-PN: table "Supported Network SFPs", row "DWDM types":
added comments to SFP/FE and SFP/2G5U on HW Rev.3.01 or
newer
• NCU-II-P: power consumption values changed
• SCU-II: power consumption values changed
Chapter 9
• passband width of the 1CSM+#G1310 changed
• updated the description of the 1CSM+#G1310 (supports DWDM
channels as well)
Chapter 10
• EDFA-C-S26-VGCB-DM added
Chapter 11
• Operating frequency range changed to 196.00 THz ... 192.00 THz
for the following modules: DCG-M/xxx/SSMF,
DCG50-M/xxx/SSMF, DCG-M/xxx/TWRS, DCG50-M/xxx/TWRS
• DCG50-M/020/SSMF added
• DCG50-M/xxx/SSMF
added note

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
o

o added chromatic dispersion values for DCG50-M/020/SSMF


and DCG50-M/040/SSMF
Appendix A:
• corrected table "ROADM Supported Channel Modules and Ampli-
fiers" for 10TCE-PCN-10G+100G and
10TCE-PCN-10G+100G-GF (do not support 100GHz grid)
• updated table “Data Rates” regarding
5TCE-PCTN-10GU+AES10G and data rate 10.7092 Gbit/s
• removed GCC0, GCC1 and GCC2 for WCC100GT-D from table
“Channel Module In-band Management Support”

804 Module and System Specification


Appendix C History of Changes

Release 12.1
Prod Document Issue 
Description
Rel. Version Date
12.1 Issue A August General (concerns some parts of the MSS)
2013
• updated maximum RAM consumption values for modules 
according to Rel. 12.1
Chapter 1
• revised section “Environmental Conditions”
• updated the lists of standards in section “Compliance Statements”
Chapter 2
• added PSU/9HU-AC
• added PSU/1HU-R-DC-200
• added power consumption value for SH1HU-R/PF
• added power consumption value for FAN/1HU
• corrected power consumption value for the rack-mounted OTDR
• added NEBS compliance for SH9HU (GR-63, Issue 4:April 2012
NEBS Requirements, Telcordia SR-3580:2012 level 3)
• PSU/9HU-DC:
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

o
changed max. input current, nominal power consumption and
max. power consumption values
o
added note regarding electrical specifications
Chapter 3
• WCC-PC1N-2G7U: added the prase "ITU-T G.8262 and IEEE
1588v2 compliant transparent Ethernet transport" to client port
-Protocols
• added WCC-PCTN-100GB
• added 10TCC-PCTN-10G+100GB
• added 10WXC-PCN-10G
• The following discontinued modules has been removed:
o
4TCC-PCN-2G1U+2G5
o
10TCC-PCTN-4GU+10G
Chapter 4
• WCA-PC-10G has been removed (discontinued module)
• 4TCA-PCN-4GUS+4G: added note on compatibility ITU-T G.813

Module and System Specification 805


Prod Document Issue 
Description
Rel. Version Date
12.1 Issue A August Chapter 5:
2013
• 10TCE-PCN-10G+100G and 10TCE-PCN-10G+100G-GF
added footnote to table "Protection Switching"
• changed power consumption values for all 5TCE variants to 42 W
• 5TCE-PCTN-10GU+10G and 5TCE-PCTN-10GU+AES10G:
added the prase "ITU-T G.8262 and IEEE 1588v2 compliant
transparent Ethernet transport" to client port -Protocols
Chapter 6
• added SFP+/11GU/CxxxxL/SM/LC
• added SFP+/11GU/1310S/SM/LC
• added SFP+/11GU/850I/MM/LC
• added SFP/GBE/B1310S/SM/LC
• added SFP/GBE/B1490S/SM/LC
• added SFP/GBE/B1310L/SM/LC
• added SFP/GBE/B1490L/SM/LC
• added SFP+CDR/10GU/850I/MM/LC
• added CFP/112G/SR10/MM/MPO

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• SFP+CDR/10GU/850I/MM/LC: changed “transmitter and receiver
fiber type” as well as “max. link distance”
• SFP+/10G/850I/MM/LC:
changed the OPR measurement range to -18 dBm ... 2 dBm
• CFP/4x28G/#DCTL/SM/LC: Entry in “Operating frequency range”
changed
• The following discontinued SFPs has been removed:
o
SFP/4GU/CxxxxL/SM/LC (only 1271 to 1451 nm)
o
SFP/2G5U/CxxxxV/SM/LC (only 1271 to 1451 nm)
o
SFP-OJDE/GBE/CxxxxV/SM/LC
Chapter 7
• The following discontinued modules has been removed:
o
OSCM-V#1630
o
2OSCM-V#1630
Chapter 8
• added 4ROADM-C96/0/OPM
• 9ROADM-C96/0/OPM: corrected slot positions in table “General
Information”
• CCM-C80/8: changed MTBF value

806 Module and System Specification


Appendix C History of Changes

Prod Document Issue 


Description
Rel. Version Date
12.1 Issue A August Chapter 9
2013
• 96CSM/4HU-#19600-#19125
corrected “Insertion loss network port Rx to network fiber detec-
tion port Tx” of MUX and DEMUX and changed value to 1.3 dB
• changed the power consumption values for the following filter
modules: 
16CSM-#D01-#D32-SFx, 16CSM-#D33-#D64-SFx,
1CSM+#Cxxxx, 1CSM+#19xxx, 1CSM+#Cxxxx-E/W,
1CSM+#19xxx-E/W, 1CSM+#G1310, 1PM/SM, 1PM/MM,
2ABSM-#C1470-#C1610, 2BSM-#D01-#D32, 2PM/SM, 2PM/MM,
2CLSM-#D01-#D64, 2CLSM-#D01-#D64-SFx, 2-OTFM+#1650,
2CSM+#G1310-#Cxxxx-E/W, 2PSM-95/5,
3BSM-#G1310-#C1610, 40CSM/2HU-#Dxx-#Dyy,
40CSM/2HU-#19590-#19200, 40CSM/2HU-#19595-#19205,
40CSM-FL/2HU-#19590-#19200, 4CSM-#Cxxxx-#Cyyyy,
40CSM-C80/2HU-#19xxx-#19yyy, 4CSM-#Dxx-#Dyy,
4CSM+#Dxx-#Dyy, 4CSM+#19xxx-#19yyy, 4GSM-#Dxx-#Dyy,
5GSM-#19590-#19200, 5PSM, 8CSM-#19xxx-#19yyy,
8CSM+#C1470-#C1610, 8GSM-#D01-#D32,
96CSM/4HU-#19600-#19125, ILM50-#DC, OSFM+#1510,
OSFM+#1630, OSFM+#1490-SFA, OSFM+#1510-SFB,
PSM-95/5
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

• The following discontinued modules has been removed:


o
1CSM+#Cxxxx-E/W
o
1CSM+#19xxx
o
1CSM/P+#Cxxxx (only variants 1270 to1450)
o
1CSM/P+#Cxxxx-E/W
o
2CSM+#G1310-#Cxxxx-E/W
o
OSFM+#1630
Chapter 10
• EDFA-C-S26-VGC-DM: description updated and statement on
need for disabling the ALS of the OSCM-PN added
• EDFA-C-S26-VGCB-DM: statement on need for disabling the ALS
of the OSCM-PN added
• EDFA-C-D27-GCB-DM: description revised and statement on
need for disabling the ALS of the OSCM-PN added
• RAMAN-C10: description updated and statement on need for dis-
abling the ALS of the OSCM-PN added
• 2RAMAN-C15-LL: statement on need for disabling the ALS of the
OSCM-PN added
• The following discontinued modules has been removed:
o
EDFA-C-S20-GCB
o
EDFA-C-D20-VGC
o
EDFA-C-D27-GCB-DM

Module and System Specification 807


Prod Document Issue 
Description
Rel. Version Date
12.1 Issue A August Chapter 11
2013
• changed the power consumption values for the following DCMs:
DCF-M/xxx/SSMF, DCG-M/xxx/SSMF, DCG-M/xxx/TWRS and
DCG50-M/xxx/SSMF
• DCF1HU-P shelf variants:
o corrected and updated Table “Chromatic Dispersion (CD) for
the Shelves with SSMF, LEAF and TWRS Fibers”
o added table “Chromatic Dispersion (CD) for the Shelves with
MCOR Fiber”
Appendix A
• updated tables according to Rel. 12.1, Issue A
Issue B October Chapter 1
2013 • Section “Right to Use Versions”:
deleted table “Supported RTU Versions”
Chapter 2
• PSU/9HU-AC: corrected values and defined circuit breaker more
precisely in table “Electrical Specifications”
• PSU/7HU-AC: defined circuit breaker more precisely in table
“Electrical Specifications”

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• PSU/7HU-AC-HP: defined circuit breaker more precisely in table
“Electrical Specifications”
• PSU/7HU-AC-800: defined circuit breaker more precisely and cor-
rected value for min. current rating in table “Electrical Specifica-
tions”
• PSU/1HU-R-AC: defined circuit breaker more precisely in table
“Electrical Specifications”
• PSU/1HU-R-AC-200: defined circuit breaker more precisely in
table “Electrical Specifications”
Chapter 3
• 10WXC-PCN-10G: added row for “Max power consumption in
stand-alone applications” and corrected value for “typ. power con-
sumption” in table “General Information”
• WCC-PCTN-100GB: removed “Loss of sequence synchronisa-
tion” from table “Link Test PRBS Functionality”
Chapter 4
• The following channel modules have been discontinued:
2TCA-PCN-1G3+2G5, 2TCA-PCN-622M+2G5

808 Module and System Specification


Appendix C History of Changes

Prod Document Issue 


Description
Rel. Version Date
12.1 Issue B October Chapter 5
2013
• WCE-PCN-100G:
o
Added maximum skew of 500 ns for client and network port
in tables “Client Port” and “Network Port”
o
Added CFP/103G/SR10/MM/MPO to table “Supported Client
CFP Types”
• 10TCE-PCN-10G+100G-GF
Added maximum skew of 500 ns in table “Network Port”
• 10TCE-PCN-10G+100G
Added maximum skew of 500 ns table “Network Port”
Chapter 6
• added XFP/16GFC/#19xxxL50/SM/LC
• added XFP/11G/#19xxxL50/SM/LC
• CFP/103G/SR10/MM/MPO: 
added the note that the shelf’s front cover cannot be used due to
the MPO cable connected.
• SFP+CDR/11GU/1310S/SM/LC: 
Added data rate of 10.518 Gbit/s to table “Technical Data”
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

• SFP/2G5U/CxxxxV/SM/LC:
changed OPR measurement range to -33dBm to -6dBm
• The following discontinued XFP/SFPs removed:
XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev. 2.00),
SFP/2G5U/1310S/SM/LC (HW Rev. 1.01 and 1.02), and
SFP-OJDE/GBE/1310S/SM/LC
Chapter 7
• NCU (NCU2E) removed (discontinued module)
Chapter 8
• Added NCU types supported by the individul ROADMs
Chapter 9
• 1PM/MM: corrected “Insertion loss” table “Optical Characteristics”
• 2PM/MM, corrected “Insertion loss” table “Optical Characteristics”
Appendix A
• Updated tables in section “Assignment of Pluggable Transceivers”

Module and System Specification 809


Prod Document Issue 
Description
Rel. Version Date
12.1 Issue C November Abbreviations
2013
• updated EFEC-4 definition
• added EFEC-6 definition
Chapter 1
• added EFEC-6 to table “FEC Codes”
Chapter 2
• PSU/9HU-DC: Copy and paste error corrected
• PSU/9HU-AC: 
Copy and paste error corrected
Rated input current added
Chapter 6
• CFP/103G/SR10/MM/MPO:
Copy and paste error corrected 
Optical power Rx from performance monitoring removed.
• CFP/4x28G/#19xxx-#19xxxL/SM/LC: 
Added OPT/OPT accuracy
• CFP/4x28G/#DCTL/SM/LC: 
Added the MTBF value 
Added OPT/OPT accuracy

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• CFP/112G/LR10R/SM/LC: added OPT/OPT accuracy
• CFP/112G/LR4/SM/LC: added OPT/OPT accuracy
• Max. module delay values for the following pluggable transceivers
added:
SFP+CDR/10GU/1550L/SM/LC, SFP+CDR/10GU/850I/MM/LC,
SFP+CDR/11GU/1310S/SM/LC, SFP+/10G/1310S/SM/LC,
SFP+/10G/850I/MM/LC, SFP+/11GU/CxxxxL/SM/LC,
SFP+/11GU/CxxxxL/SM/LC, SFP+/11GU/1310S/SM/LC,
SFP+/11GU/850I/MM/LC, SFP+/8GU/1310S/SM/LC,
SFP+/8GU/850I/MM/LC
• XFP/16GFC/#xxxxxL/SM/LC#Dxx:
Max. module delay changed to 3 ns
Appendix A
• Table “ROADM Supported Channel Modules and Amplifier” cor-
rected
• Table “CCM Supported Channel Modules and Amplifiers” cor-
rected

810 Module and System Specification


Appendix C History of Changes

Release 12.2
Prod Document Issue 
Description
Rel. Version Date
12.2 Issue A December General (concerns some parts of the MSS)
2013
• Updated maximum RAM consumption values for modules 
according to Rel. 12.2
Chapter 2
• added SH1HU-HP/E-TEMP/2DC shelf
Chapter 3
• WCC-PCTN-100GB:
Added Client channel card protection and versatile switched pro-
tection
• 10TCC-PCTN-10G+100GB:
Added Full STM64/OC192 support
• 10TCC-PCN-2G7US+10G:
o
Added support of STM-1/OC-3, STM-4/OC-12,
STM-16/OC-48 and OTU1 signals
o
Added support of client channel card protection
o
Added FR-ALS functionality with pulses in 5 sec.
o
Added support of ECC on client ports
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

o
Added XFP/11G/#19xxxL50/SM/LC
• 2TWCC-PCN-2G7U
o Added ODU0 mapping
o Rate Limiting
Chapter 5
• 5TCE-PCTN-10GU+AES10G:
Max. power consumption value corrected (copy and paste error)
Chapter 7
• OSCM-PN: added statement on the OLM functionality
Chapter 8
• Added OPT/OPR 50ms sampling rate specification to the
9ROADM-C96/0/OPM
Chapter 9
• Added Y-cable variants
• Added EFFA-S20L
• Added EDFA-S20H

Module and System Specification 811


Prod Document Issue 
Description
Rel. Version Date
12.2 Issue A December Chapter 10
2013
• Revised Transient Response specification on the following
amplifiers:
o
EDFA-C-S20-GCB-DM
o
EDFA-C-D20-VGC-DM
o
EDFA-C-D20-VLGC-DM
o
EDFA-C-S26-VGC-DM
o
EDFA-C-S26-VGCB-DM
o
AMP-S20H-C15
o AMP-S20L-C15
o EDFA-S20H
o EDFA-S20L
• Added OPT/OPR 50ms sampling rate specification to the
following amplifiers:
o
EDFA-C-S20-GCB-DM
o
EDFA-C-D20-VGC-DM
o
EDFA-C-D20-VLGC-DM
o
EDFA-C-S26-VGCB-DM
o
AMP-S20H-C15
o
AMP-S20L-C15
o
EDFA-S20H

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
o
EDFA-S20L
o
RAMAN-C10
Issue B January Chapter 3
2014
• 2TWCC-PCN-2G7U 
added Client Channel Card protection feature
• 10WXC-PCN-10G
removed XFP/11G/Dxxxx.xxV/SM/LC#Dxx from table “ Supported
SFPs“ and added XFP/11G/Dxxxx.xxV/SM/LC#Dxx
Chapter 4
• 2WCA-PCN-10G 
added XFP/8G/CxxxxL/SM/LC to table “Supported Network
XFPs”
Chapter 6
• CFP/112G/LR4/SM/LC 
added OPR measurement range to table “Technical Data”
Chapter 8
• 9ROADM-C96/0/OPM 
corrected channel spacing in table “Optical Characteristics -Gen-
eral”

812 Module and System Specification


Appendix C History of Changes

Prod Document Issue 


Description
Rel. Version Date
12.2 Issue B January Chapter 10
2014
• AMP-S20H-C15 and AMP-S20L-C15 
updated item “Insertion loss C-R to N-T” in table “Optical Specifi-
cation Client Ports”
• EDFA-S20H and EDFA-S20L
added item “Insertion loss C-R to N-T” to table “Optical Specifica-
tion Client Ports”
Appendix A
• Table “XFPs at the Client Ports”
removed XFP/11G/#xxxxxV/SM/LC#Dxx and added
XFP/16GFC/#19xxxL50/SM/LC
• Table “XFPs at the Network Ports”
removed XFP/11G/#xxxxxV/SM/LC#Dxx (wrong name)
Issue C February Chapter 2
2014
• SH9HU and PSU/9HU-DC:
added statement on supporting a mix of 1000-W AC and DC
power supplies per 9HU shelf
• OTDR: Removed statement that the OTDR is not supported by
the NCU-II-P
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Chapter 3
• WCC-PCTN-100GA:
corrected MTBF value in table 183
• WCC-PCTN-100GB:
o
added value for “Max. Ethernet Frame Size” to table 169
o
corrected MTBF value in table 162
o
added SyncE compliance (table 164 „Jitter and Wander
Compliance“)
• 10TCC-PCTN-10G+100GB:
o added SyncE compliance (table 202 „Jitter and Wander
Compliance“)
o added value for “Max. Ethernet Frame Size” to table 207
• 10TCC-PCN-2G7US+10G:
corrected MTBF value in table 302
• 10WXC-PCN-10G:
o replaced XFP/11G/#xxxxxV/SM/LC#Dxx with
XFP/11G/Dxxxx.xxV/SM/LC#Dxx in table 331
o added SyncE compliance (table 331 „Jitter and Wander
Compliance“)
Chapter 4
• 2WCA-PCN-10G:
added XFP/8G/CxxxxL/SM/LC to table 471

Module and System Specification 813


Prod Document Issue 
Description
Rel. Version Date
12.2 Issue C February Chapter 6
2014
• SFP+/10G/850I/MM/LC:
corrected MTBF value in table 699
Chapter 8
• 4ROADM-C96/0/OPM: 
corrected MTBF format in table 872
Chapter 9
• PSM-95/5: 
corrected MTBF value in table 1069
Appendix A
Table “ROADM Supported Channel Modules and Amplifiers updated”
(regarding interworking ROADMs with optical amplifiers)

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

814 Module and System Specification


Appendix C History of Changes

Release 12.3
Prod Document Issue 
Description
Rel. Version Date
12.3 Issue A March 2014 General (Concerns some chapters of the MSS)
• Maximum RAM consumption values on NCU for modules 
according to Rel. 12.3 updated
Chapter 1
• section “Optical Power Measurement”
Chapter 2
• SH1HU-HP/E-TEMP/2DC
Safety instruction added
Chapter 3
• The following discontinued modules removed:
o
WCC-TN-40G-L#DC
o
4TCC-PCTN-10G+40G-L#DC
• 10WXC-PCN-10G:
o added STM-64, OC-192, 10G-WAN data rates
o added TCAs on LO ODUk PMs
o added OTN mapping for STM-64, OC-192, 10G-WAN
added GCC1/ GCC2 for ODU2/ ODU2e
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential

Chapter 5
• WCE-PCN-100GB added
• WCE-PCN-100G: CCCP for 100GbE client services added
• 10TCE-PCN-16GU+AES100G added
• 5TCE-PCN-10GU+10G added
• 5TCE-PCN-10GU+AES10G added
• 4WCE-PCN-16GFC
o SFP+/11GU/850I/MM/LC added as client plug
o SFP+/11GU/1310S/SM/LC added as client plug
• 5TCE-PCTN-10GU+10G
o
SFP+/11GU/850I/MM/LC added as client plug
o
SFP+/11GU/1310S/SM/LC added as client plug
• 5TCE-PCTN-10GU+AES10G
o
SFP+/11GU/850I/MM/LC added as client plug
o
SFP+/11GU/1310S/SM/LC added as client plug
• 5TCE-PCTN-8GU+10GS
o SFP+/11GU/850I/MM/LC added as client plug
o SFP+/11GU/1310S/SM/LC added as client plug

Module and System Specification 815


Prod Document Issue 
Description
Rel. Version Date
12.3 Issue A March 2014 Chapter 5
• 5TCE-PCTN-8GU+AES10GS
o
SFP+/11GU/850I/MM/LC added as client plug
o
SFP+/11GU/1310S/SM/LC added as client plug
Chapter 6
• SFP+CDR/11GU/CxxxxL/SM/LC added
• SFP+CDR/11GU/CxxxxS/SM/LC added
• SFP+/11GU/#19xxxL50/SM/LC added
Chapter 7
• Following discontinued modules removed:
o
RSM-SF#1310
o
RSM-SF#1510
• SCU and SCU-II: 
maximum number of shelves connected in one network element
increased from 20 main shelves to 25 main shelves
Chapter 8
• Following tables of the 9ROADM-C96/0/OPM revised:
o
Optical Characteristics - Network Port

FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
o
Optical Characteristics - Client Ports
o
Fault Monitoring - General
o
Fault Monitoring EDFA Submodule
o
Performance Monitoring Client Interface - General
o
Performance Monitoring Network Interface - General
o
Performance Monitoring Virtual Channel at Network Port
o
Performance Monitoring EDFA Submodule
• CCM-C96/9 added
Chapter 9
• 8PSM added
• J/SM/4CS-#C1270-#C1330/LC/0400 added
Chapter 10
• 2EDFA-S20L-S10L added

816 Module and System Specification

You might also like