FSP3000R7 R12.3 Module System Specification IssA
FSP3000R7 R12.3 Module System Specification IssA
2
Table of Contents
Related Documents Overview. . . . . . . . . . . . . . . . . . . . 13
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Purpose and Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Publication History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Typographic Conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Safety Symbol and Message Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Obtaining Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
World Wide Web. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Documentation Disc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Ordering Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Documentation Feedback. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Chapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . 55
Wavelength Plan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
DWDM Wavelengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
CWDM Wavelengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Defined Operating Network Wavelengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Interoperability of Channel Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
FEC Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Right to Use Versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Supported Shelf ID Range and Amount of Shelves per Node. . . . . . . . . . . . . . . . . . . . . . . . 62
Compliance Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
International . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
European Union . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
USA and Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
PSU/7HU-R-DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
PSU/7HU-R-DC-HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
PSU/7HU-AC-800. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
FAN/Plug-In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
SH1HU-HP/2DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
SH1HU-HP/E-TEMP/2DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
SH1HU-F/2DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
SH1HU-R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
SH1HU-R/PF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
PSU/1HU-R-AC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
PSU/1HU-R-AC-200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
PSU/1HU-R-DC-200. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
FAN/1HU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
SH1HU/PASSIVE/FT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
FMT/1HU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
OTDR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFP+CDR/11GU/1310S/SM/LC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 418
SFP+CDR/11GU/CxxxxL/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 420
SFP+CDR/11GU/CxxxxS/SM/LC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 422
SFP+/10G/1310S/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 424
SFP+/10G/850I/MM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 425
SFP+/11GU/#19xxxL50/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 426
SFP+/11GU/CxxxxL/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 428
SFP+/11GU/1310S/SM/LC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 430
SFP+/11GU/850I/MM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 431
SFP+/8GU/1310S/SM/LC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433
SFP+/8GU/850I/MM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 434
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 435
SFP/4GU/CxxxxV/SM/LC (HW Rev. 2.01). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 436
SFP/4GU/CxxxxV/SM/LC (HW Rev. 3.01). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 437
SFP/4GU/1310S/SM/LC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 438
SFP/4GU/850I/MM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 439
SFP/4GU/CxxxxL/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 440
SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 442
SFP/2G5U/CxxxxV/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 444
SFP/2G5U/CxxxxL/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 446
SFP/FE/C1490V/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 468
SFP/FE/C1510V/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 469
SFP/FE/D1528.77E/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 470
SFP/FE/Dxxxx.xxV/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 471
CFP/112G/LR10R/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 472
CFP/112G/LR4/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 475
CFP/103G/SR10/MM/MPO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 478
CFP/4x28G/#19xxx-#19xxxL/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 480
CFP/4x28G/#DCTL/SM/LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 483
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
40CSM/2HU-#19595-#19205. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 562
40CSM-FL/2HU-#19590-#19200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 564
40CSM-C80/2HU-#19xxx-#19yyy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 566
40CSM/P-2HU#19590-#19200-DM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 568
96CSM/4HU-#19600-#19125. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 570
2BSM-#D01-#D32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 572
4GSM-#Dxx-#Dyy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 574
8GSM-#D01-#D32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 576
1GSM+#Dxx-#Dyy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 578
5GSM-#19590-#19200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 580
8CSM-#19xxx-#19yyy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 582
4CSM+#19xxx-#19yyy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 585
4CSM-#Dxx-#Dyy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 587
4CSM+#Dxx-#Dyy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 589
1CSM+#Dxx-E/W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 591
1CSM+#19xxx-E/W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 593
2CLSM-#D01-#D64-SFx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 595
16CSM-#D01-#D32-SFx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 597
16CSM-#D33-#D64-SFx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 599
OSFM+#1490-SFA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 601
2PSM-95/5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 641
1PM/SM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 643
1PM/MM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 644
2PM/SM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 645
2PM/MM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 646
Y-Cable/SM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 647
Y-Cable/MM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 649
J/SM/4CS-#C1270-#C1330/LC/0400. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 651
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ROADM Supported Channel Modules and Amplifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 748
CCM Supported Channel Modules and Amplifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 750
ROADM Compatible Pluggable Transceivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 752
CCM Compatible Pluggable Transceivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 753
Loop Functionality Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 753
Channel Module Protection Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 755
Channel Module Regeneration Capabilities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 758
Data Rates and Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 761
Channel Module Services. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 763
Channel Module Data Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 767
Channel Module In-band Management Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 771
Channel Module Error Signaling on Client Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 774
Pluggable Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 775
XFP/SFP/CFP Gray Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 775
XFP/SFP/CFP Colored Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 779
Assignment of Pluggable Transceivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 781
XFPs at the Client Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 781
XFPs at the Network Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 782
SFPs at the Client Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 783
SFPs at the Network Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 786
Planning
• Planning and Engineering Guide
This is a reference document. Part I describes the architecture and
principles behind major features such as transport protocols, protection,
optical amplification, reconfigurable OADMs, DCN, control plane, and
management-related features.
Part II describes physical details about each module such as front plate
pictures and markings, signal path description with block diagrams, and
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
allowed placement and labeling of the modules. For details related to the
supported configurations of each module, parameter values, and other
management related data, refer to the Management Data Guide.
Installing
• Critical Warnings
This document lists the most important safety requirements as well as input
power restrictions for channel modules and pluggable transceivers. Read
this document before installing, provisioning, configuring or operating the
FSP 3000R7.
• Safety Guide
This document describes important safety precautions that are to be read
and observed before attempting to install, provision, configure or operate
the FSP 3000R7. Therefore, read this document first.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
while following the procedures in the Provisioning and Operations Manual to
look up provisioning and management-related details.
• Management Data Guide
This document contains all provisionable and read-only parameters for
each module, as well as the performance counters for the modules. This is
a useful reference both when planning and engineering a network and while
following the instructions in the management tool procedural
documentation.
• OTDR Installation, Provisioning, and Operations Manual
This document covers installation, provisioning, operations,
troubleshooting, and maintenance of the OTDR unit.
In this specification, you can find short function descriptions and detailed
technical data. This is the correct reference if you are planning an optical
network containing FSP 3000R7 components.
This document lists the fault cause persistency filtered (FCPF) conditions for
each module in the corresponding fault monitoring tables. Please refer to the
Planning and Engineering Guide for more information about FCPF conditions.
Audience
This documentation is primarily intended to be read by any persons who need
details on technical data and short function descriptions of the supported
modules.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Issue C February 2010
9.3 80000010623 Issue A March 2010 For details see
Issue B May 2010 Appendix C: History of Changes
Issue C May 2010
Issue D July 2010
Issue E August 2010
10.1 80000011726 Issue A September 2010 For details see
Issue B Appendix C: History of Changes
Issue C
Issue D
Issue E January 2011
10.2 80000014010 Issue A October 2010 For details see
Issue B December 2010 Appendix C: History of Changes
Issue C March 2011
Issue D April 2011
10.3 80000014672 Issue A May 2011 For details see
Issue B July 2011 Appendix C: History of Changes
Issue C October 2011
11.1 80000015933 Issue A March 2012 For details see
Issue B April 2012 Appendix C: History of Changes
Issue C June 2012
Organization
This documentation is organized as follows:
Preface
Describes the purpose, audience, organization and the conventions, that are
used throughout this documentation. In addition, important ADVA Optical
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Chapter 1: Introduction
This chapter provides an overview of the wavelengths used for the Fiber Service
Platform (FSP 3000R7) and gives information about the defined operating
network wavelengths, FEC codes, equipment disposal, power consumption
values, conformance of laser products and EMC classification.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This chapter provides short function descriptions and detailed technical data of
the various types of passive optical modules, such as channel splitter modules
(CSMs), group splitter modules (GSMs), band splitter modules (BSMs), optical
supervisory filter module (OSFM) and protection modules (PMs) available.
Document Conventions
This section lists the common typographical and symbol use for FSP 3000R7
documents.
Typographic Conventions
The documentation follows these typographic conventions:
Convention Description
boldface font Indicates keywords and emphasized words when
appearing in main text areas. All warnings are in
boldface font.
blue font Indicates a reference to a chapter, section, figure,
table or related documentation when appearing in
main text areas.
CAPITALIZED font Refers to the keys on your keyboard, e.g. ENTER
marked
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Documentation Disc
The FSP 3000R7 User Documentation Suite is available on the disc that is
delivered with the product. The disc also contains the USB driver required for
establishing a USB serial connection.
Ordering Documentation
ADVA Optical Networking customers can order the FSP 3000R7 User
Documentation Suite and additional literature through a local ADVA Optical
Networking sales representative. For more current product release information,
please refer to the home page, or contact the Technical Services of ADVA
Optical Networking. See “Obtaining Technical Assistance” on p. 25 and
“Contact ADVA Optical Networking” on p. 26 for contact details.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Documentation Feedback
We want our FSP 3000R7 documentation to be as helpful as possible.
Feedback regarding the guide is therefore always welcome.
You can e-mail your comments/suggestions to:
global-techdocu@advaoptical.com
To submit your comments/suggestions by mail, use the following address:
ADVA Optical Networking SE
Technical Documentation
Maerzenquelle 1-3
98617 Meiningen-Dreissigacker
Germany
We appreciate and value your comments/suggestions to improve the quality of
the guide.
Customer Portal
The ADVA Optical Networking Customer Portal provides a suite of interactive,
networking services that provide immediate access to company information and
resources at any time, from anywhere in the world. This highly integrated
internet application is a powerful, easy-to-use tool for doing business with ADVA
Optical Networking.
The broad range of features and services provided by the portal help customers
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Technical Services
Technical services are available to warranty or maintenance contract customers
who need technical assistance with a product from ADVA Optical Networking
that is under warranty or covered by a maintenance contract. To access
Technical Services, including all contact information, go to the ADVA Optical
Networking home page at:
http://www.advaoptical.com
Americas:
Support-Americas@advaoptical.com
Asia Pacific:
SAsia@advaoptical.com
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
+1 687 728 8600
info@advaoptical.com
www.advaoptical.com
Symbols/Numerics
°C degree Celsius
°F degree Fahrenheit
10 GbE 10 gigabit Ethernet
10 GbE LAN 10 gigabit Ethernet used in Local Area Network
10 GbE LAN PHY 10 gigabit Ethernet LAN physical layer
10 GbE WAN 10 gigabit Ethernet used in Wide Area Network
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
rate on the network port of 10 Gbit/s
10TCC-PCTN-4GUS+10G Core type 10-port TDM channel module with ten pluggable
interfaces on the client side and one integrated 10 Gigabit
DWDM interface on the network side that is fully tunable in
the C or L band; the client interfaces support GbE, 1GFC,
2GFC, 4GFC, STM-1/OC-3, STM-4/OC-12 and
STM-16/OC-48 services; module is available in three
variants (collective name)
10TCC-PCTN-4GUS+10G-LN#DC Core type 10-port TDM channel module with ten pluggable
interfaces on the client side and one integrated, 10 G long
reach link, noise optimized 50 GHz-spaced tunable DWDM
interface on the network side; support of C-band channels
only; client port data rates between 155.52 Mbit/s and
4.2500 Gbit/s; maximum aggregated data rate on the
network port of 10.7 Gbit/s
10TCC-PCTN-4GUS+10G-V#DC Core type 10-port TDM channel module with ten pluggable
interfaces on the client side and one integrated, 10G very
long reach link, 50 GHz-spaced tunable DWDM interface
on the network side; support of C-band channels only;
client port data rates between 155.52 Mbit/s and
4.2500 Gbit/s; maximum aggregated data rate on the
network port of 10.7 Gbit/s
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
1PM/SM single-port protection module single-mode
2-OTFM+#1650 optical time-domain reflectometer filter module with
upgrade port, OTDR wavelength at 1650 nm
2.5G 2.5 gigabit
2ABSM-#C1470-#C1610 2-port CWDM subband splitter module (It splits the 8
CWDM channels into two groups of 4 channels each and
vice versa.)
2BSM-#D01-#D32 2-port DWDM red/blue splitter module - C band
2BSM/P-#G1310-#C1610-DM passive 2-port CWDM band splitter module with gray
interface at 1310 nm and monitoring port for dual power
level monitoring
2CLSM C-band/L-band splitter (short form for 2CLSM-#D01-#D64
or 2CLSM-#D01-#D64-SFx)
2CLSM-#D01-#D64-SFA DWDM 2-port C/L band splitter module - single-fiber
working, location A
2CLSM-#D01-#D64-SFB DWDM 2-port C/L band splitter module - single-fiber
working, location B
2CLSM-#D01-#D64-SFx DWDM 2-port C/L band splitter module - single-fiber
working (collective name)
2EDFA-S20L-S10L dual optical amplifier module with 20dB and 10dB EDFAs;
supports 96 C-band channels, 15 to 30 dB span loss, OSC
filter and level control, Fiber Map Detection
2G CL 2 gigabit Coupling Link
2G FC 2 gigabit Fibre Channel (a network technology working at a
line rate of 2.125 Gbit/s)
Gbit/s
3BSM-#G1310-#C1610 CWDM band splitter module with gray interface at 1310 nm
3R reshaping, reamplifying and retiming (signal regeneration)
4-OPCM 4-port Optical Power Control Module; the module has
VOAs (Variable Optical Attenuators) managed by the
NE-SW as alternative to pluggable fixed attenuators
40CSM-C80/2HU-#19590-#19200 40-port MUX/DMX channel splitter/combiner 2HU shelf -
even C band channels, used for dual client configuration
with the 8ROADM-C80/0/OPM
40CSM-C80/2HU-#19595-#19205 40-port MUX/DMX channel splitter/combiner 2HU shelf -
odd C-band channels, used for dual client configuration
with the 8ROADM-C80/0/OPM
40CSM-C80/2HU-#19xxx-#19yyy 40-port MUX/DMX channel splitter/combiner 2HU shelf -
C-band channels, used for dual client configuration with
the 8ROADM-C80/0/OPM (collective name)
40CSM-FL/2HU-#19590-#19200 40-port MUX/DMX channel splitter/combiner 2HU shelf -
even C band channels for signal transport and for fibers
going to the left side
40CSM/2HU-#19590-#19200 40-port MUX/DMX channel splitter/combiner 2HU shelf -
even C band channels and for fibers going to the right side
40CSM/2HU-#19595-#19205 40-port MUX/DMX Channel Splitter and Combiner 2HU
Shelf for 50-GHz interleaved C-band channels
40CSM/2HU-#D02-#D32 40-port MUX/DMX Channel Splitter 2HU Shelf - C band
40CSM/2HU-#D02-#D32 40-port MUX/DMX Channel Splitter 2HU Shelf - C band
40CSM/2HU-#D34-#D64 40-port MUX/DMX Channel Splitter 2HU Shelf - L band
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
4ROADM-C96/0/OPM Reconfigurable Optical Add Drop Multiplexer for up to
degree 4 interconnection nodes; supports 96 C-band
channels and optical power monitoring; WSS based, with
integrated 1x4 power splitter, directed/directionless,
gridless, colored/colorless, for dual client applications from
1 to 3 degrees. additional dual pass through
4TCA-PCN-4GU+4G access type 4-port TDM channel module with four client
and two network pluggable interfaces; maximum client
data rate of 4 Gbit/s; multirate clock user selectable;
aggregated data rate on the network port of 4 Gbit/s
4TCA-PCN-4GUS+4G Access type 4-port TDM channel module with four client
and two network pluggable interfaces; supports 1GbE,
STM-1/OC-3 and STM-4/OC-12 on the client ports;
aggregated data rate on the network port of 4.25 Gbit/s
4TCC-PCN-2G1U+2G5 core Type 4-Port multirate TDM channel module with four
client and two network pluggable interfaces; max. client
data rate of 2.125 Gbit/s; aggregated data rate on the
network port of 2.5 Gbit/s
4TCC-PCTN-2G7+10G-LN#DC core type 4-port TDM channel module with four pluggable
interfaces on the client side and one long reach link,
tunable DWDM network interface on the network side;
maximum client data rate of 2.7 Gbit/s; aggregated data
rate on the network port of 10 Gbit/s
CCM-C80/8
5TCE-PCN-10GU+10G enterprise type 5-port TDM channel module with five
SFP/SFP+ interfaces on the client side and a single SFP+
interface on the network side; maximum client data rate of
10.5 Gbit/s; maximum aggregated data rate on the network
port of 11.3 Gbit/s
5TCE-PCN-10GU+AES10G enterprise type 5-port TDM channel module with five
SFP/SFP+ interfaces on the client side and a single SFP+
interface on the network side supporting data encryption;
maximum client data rate of 10.5 Gbit/s; maximum
aggregated data rate on the network port of 11.3 Gbit/s
5TCE-PCTN-10GU+10G enterprise type 5-port TDM channel module with five
pluggable client interfaces and one integrated 10 Gigabit
DWDM network interface that is fully tunable in the C or L
band; module is available in three variants (collective
name)
5TCE-PCTN-10GU+10G-LN#DC enterprise type 5-port TDM channel module with five
pluggable interfaces on the client side and one integrated
10 Gigabit long reach noise optimized tunable
50 GHz-spaced DWDM interface on the network side;
support of C-band channels only; maximum client data rate
of 10.5 Gbit/s; maximum aggregated data rate on the
network port of 11.3 Gbit/s
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
50 GHz-spaced DWDM interface on the network side
supporting data encryption; maximum client data rate of
10.5 Gbit/s; maximum aggregated data rate on the network
port of 11.3 Gbit/s
5TCE-PCTN-10GU+AES10G-V#DC enterprise type 5-port TDM channel module with five
pluggable interfaces on the client side and one integrated
10 Gigabit very long reach C-band tunable 50 GHz-spaced
DWDM interface on the network side supporting data
encryption; maximum client data rate of 10.5 Gbit/s;
maximum aggregated data rate on the network port of 11.3
Gbit/s
5TCE-PCTN-10GU+AES10G-V#DL enterprise type 5-port TDM channel module with five
pluggable interfaces on the client side and one integrated
10 Gigabit very long reach, L-band tunable
100 GHz-spaced DWDM interface on the network side
supporting data encryption; maximum client data rate of
10.5 Gbit/s; maximum aggregated data rate on the network
port of 11.3 Gbit/s
5TCE-PCTN-8GU+10GS Enterprise type 5-port TDM channel module with five
pluggable client interfaces and one integrated 10 Gigabit
DWDM network interface that is fully tunable in the C band
and supports SDH/Sonet; module is available in two
variants:
5TCE-PCTN-8GU+10GS-LN#DC,
5TCE-PCTN-8GU+10GS-V#DC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
frequencies from 191.25 THz through 196.00 THz; each
client port used for add-drop services reduces the potential
number of degrees supported.
ohm (SI unit of electrical impedance or, in the direct current
case, electrical resistance)
µm micrometer
µs microsecond
A
A ampere
AC alternating current
acc. according to
ADM add-drop multiplexer
ADVA ADVA Optical Networking
AES advanced encryption standard
AID access identifier
AINS automatic in-service
AIS alarm indication signal
ALS automatic laser shutdown
amp amplifier
B
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
C
CBS Committed Burst Size (bandwidth profile parameter according to MEF)
CCM-C40/8 8-port colorless channel module supporting 40 C-band channels, WSS
based
CCM-C80/8 8-port colorless channel module supporting 80 C-band channels, WSS
based
CCM-C96/9 9-port colorless channel module supporting 96 C-band channels, WSS
based
CDR clock and data recovery
CE corrected errors
CEM/9HU Common Equipment Module for 9HU Shelf, with PSCU and UTM
functionality, one CEM/9HU required per 9HU Shelf
CFP centum form factor pluggable
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
D- data (line balanced)
D+ data (line balanced)
dB decibel
dBm decibel milliwatt
DC direct current
DCCm data communications channel for multiplexer section
DCCr data communications channel for regenerator section
DCD data carrier detect (serial connection)
DCF dispersion compensating fiber
DCF1HU-P dispersion compensation shelf with an integrated DCF spool,
rack-mountable, 1 HU high
DCF1HU-P/010/MCOR dispersion compensation shelf with an integrated DCF spool that
compensates for 10 km of G. 655 MetroCore fiber
DCF1HU-P/020/MCOR dispersion compensation shelf with an integrated DCF spool that
compensates for 20 km of G. 655 MetroCore fiber
DCF1HU-P/020/SSMF dispersion compensation shelf with an integrated DCF spool that
compensates for 20 km of G. 652 standard single-mode fiber
DCF1HU-P/030/MCOR dispersion compensation shelf with an integrated DCF spool that
compensates for 30 km of G. 655 MetroCore fiber
DCF1HU-P/040/MCOR dispersion compensation shelf with an integrated DCF spool that
compensates for 40 km of G. 655 MetroCore fiber
DCF1HU-P/040/SSMF dispersion compensation shelf with an integrated DCF spool that
compensates for 40 km of G. 652 standard single-mode fiber
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The part /xxx of the module name refers to the compensation capability
of C-band channels in a 100 GHz channel grid.
DCG-M/160/TWRS Fiber-Bragg-Grating dispersion compensation module that compensates
in a 100 GHz channel grid for 160 km of true wave-reduced-slope fiber
DCG-M/240/TWRS Fiber-Bragg-Grating dispersion compensation module that compensates
in a 100 GHz channel grid for 240 km of true wave-reduced-slope fiber
DCG-M/320/TWRS Fiber-Bragg-Grating dispersion compensation module that compensates
in a 100 GHz channel grid for 320 km of true wave-reduced-slope fiber
DCG-M/xxx/TWRS Fiber-Bragg-Grating dispersion compensation module for compensating
the chromatic dispersion of true wave-reduced-slope fiber (collective
name)
The part /xxx of the module name refers to the compensation capability.
DCG50-M/060/SSMF Fiber-Bragg-Grating dispersion compensation module that compensates
in a 50 GHz channel grid for 60 km of G. 652 standard single-mode fiber
DCG50-M/080/SSMF Fiber-Bragg-Grating dispersion compensation module that compensates
in a 50 GHz channel grid for 80 km of G. 652 standard single-mode fiber
DCG50-M/100/SSMF Fiber-Bragg-Grating dispersion compensation module that compensates
in a 50 GHz channel grid for 100 km of G. 652 standard single-mode fiber
DCG50-M/xxx/SSMF Fiber-Bragg-Grating dispersion compensation module (collective name)
The part /xxx of the module name refers to the compensation capability
of C-band channels in a 50 GHz channel grid.
DCG50-M/160/TWRS Fiber-Bragg-Grating dispersion compensation module that compensates
in a 50 GHz channel grid for 160 km of true wave-reduced-slope fiber
DCG50-M/240/TWRS Fiber-Bragg-Grating dispersion compensation module that compensates
in a 50 GHz channel grid for 240 km of true wave-reduced-slope fiber
E
E extension
e.g. for example (exempli gratia)
e/o electrical to optical conversion
ECC embedded control channel
EOC embedded operations channel
EDFA Erbium-Doped Fiber Amplifier (collective name)
EDFA-C-D17-GC optical amplifier, double stage 17 dBm maximum output power, gain
controlled (C band)
EDFA-C-D20-VGC-DM full-band, variable gain and transient-controlled, double-stage, dual
monitoring C-band EDFA module, 21.3 dBm maximum output power
EDFA-C-D20-VLGC-DM full-band, variable low gain and transient-controlled, double-stage, dual
monitoring C-band EDFA module, 20.5 dBm maximum output power
EDFA-C-S20-GCB-DM full-band, fixed gain and transient-controlled booster, single-stage, dual
monitoring C-band EDFA module, 18.5 dBm maximum output power
EDFA-C-S26-VGC-DM full band, variable gain and transient-controlled single-stage, C-band
EDFA module, maximum output power of 27 dBm, OSC center
wavelength of 1510 nm
EDFA-C-S26-VGCB-DM full band, variable gain and transient-controlled booster, single-stage,
dual monitoring, C-band EDFA module, maximum output power of
26 dBm, OSC center wavelength of 1528.77 nm
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
EOC embedded operations channel
EPT error propagation code
EPL Ethernet Private Line
eROADM (1) electrically-reconfigurable optical add/drop multiplexer
(2) enhanced reconfigurable optical add/drop multiplexer
EQPT equipment
ES errored seconds
E-TREE Ethernet tree service
ESCON enterprise system connection
ESD electrostatic discharge
ETSI European Telecommunications Standards Institute
ETH-CC Ethernet Continuity Check
EVC Ethernet Virtual Connection
Even channels channels with frequencies of 196.00 THz to 192.00 THz (#D01 to #D32)
with a spacing of 100 GHz
EVPL Ethernet Virtual Private Line
F
F2488 2.488 gigabit
F9953 9.953 gigabit
FAN/9HU plug-in fan unit for the 9HU Shelf
G
g gram (SI base unit of mass)
G gigabit
GbE gigabit ethernet
Gbit/s gigabits per second
GCC0 generic communication channel 0 in the OTU overhead
GCC1 generic communication channel 1 in the OTU overhead
GCC2 generic communication channel 2 in the OTU overhead
GFEC Reed-Solomon FEC code according to ITU-T G.975
GFP generic framing procedure according to ITU-T G.7041
GFP-F generic framing procedure, frame-mapped
GFP-T generic framing procedure, transparent-mapped
GHz gigahertz
G-Link Gigabit link
GMP Generic Mapping Procedure according to ITU-T G.709 (for mapping a
client signal with any bit rate less than the payload capacity to the ODU
GND signal ground (serial connection)
GSM group splitter module
I
IB InfiniBand (protocol)
i.e. that is (id est)
I/O input/output
IEC International Electronical Commission
ID identification (identification number)
ILM50-#DC passive optical module that provides signal interleaving and
de-interleaving in 50-GHz channel spacing DWDM systems. It is
optimized to cover the C-band channels only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
I-NNI Internal-Network to Network Interface
in inch(es)
Intel IXF19303 Device bandwidth aggregation and channelizer devices with virtual
concatenation
IP [1] internet protocol
[2] ingress protection, a term that refers to the classification of the
protection level that electrical appliances provide
IPv4 internet protocol version 4
ITU International Telecommunication Union
ITU-T ITU Telecommunications Standardization Sector
J
J/SM/4CS-#C1270-#C1 5-port unidirectional CWDM channel splitter/combiner for channels
330/LC/0400 #C1270 - #C1330. It is designed for connecting a 40G transceiver CFP
(LR4) to four 10G transceiver SFP+ interfaces, enabling transmission of
40G traffic over 10G channels.
K
kg kilogram (SI base unit of mass)
km kilometer (SI unit of length in the metric system)
M
m meter
MAC media access control
MAN metropolitan area network
max. maximum
Mbit/s megabits per second
MDF Medium Dispersion fiber
MEA mismatch equipment alarm
MEF Metro Ethernet Forum (is a nonprofit international industry consortium,
dedicated to worldwide adoption of Carrier Ethernet networks and
services)
MEP Maintenance Entity Group End Point
mi mile(s)
MIB management information base -> Glossary
min. minimum
mm millimeter
MOD module
ms millisecond
N
NAT network address translation
N-C bidirectional regeneration network-to-client interface
NCU network element control unit
NCU-II network element control unit, second generation, with high performance
processor
NCU-II-P network element control unit, second generation, supporting High
Availability set-ups
NE network element
NEBS Network Equipment Building Standards
NECG net electrical coding gain
NEND near end
NE-R receiver (connector) for the network port east
NE-T transmitter (connector) for the network port east
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
nm nanometer
NMS network management system
N-N bidirectional regeneration network-to-network interface
NNI Network to Network Interface (is an interface which specifies signaling
and management functions between two networks)
NPCUP network protected client unprotected protection
N-R receiver (connector) for the network port
NSAP network service access point
N-T transmitter (connector) for the network port
NTP network time protocol
NW-R receiver (connector) for the network port west
NW-T transmitter (connector) for the network port west
O
o/e optical to electrical conversion
OA optical amplifier
OAM remote operations, administration and maintenance
OC-1 optical carrier level 1 (with 51.84 Mbit/s)
OC-12 optical carrier level 12 (with 622 Mbit/s)
OC-192 optical carrier level 192 (with 9.953 Gbit/s)
OC-3 optical carrier level 3 (with 155 Mbit/s)
OC-48 optical carrier level 48 (with 2.5 Gbit/s)
P
PC personal computer
PCB printed circuit board
PCS physical coding sublayer
PDU (1) protocol data unit
(2) power distribution unit
PG (1) protection group mode
(2) protection group (a pair of client ports on the same or different
channel modules)
PG-P protection group mode - protection traffic
PG-W protection group mode - working traffic
Pin max maximum permissible optical input power at network port receiver
PLC planar lightwave circuit
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
PLM payload mismatch
PM protection module (collective name)
performance monitoring
PMD polarization mode dispersion
ppm (oscillator) parts-per-million
PPP point-to-point protocol
ps pico second
PSCP PuTTY secure copy program
PSCU Passive Shelf Control Unit
PSM-95/5 power splitter module for power monitoring and optical spectrum analysis
PSU power supply unit
PSU/1HU-R-AC AC power supply unit for a 1HU shelf with rear power access
PSU/1HU-R-AC-200 AC power supply unit for a 1HU shelf with rear power access;
It delivers a maximum output power of 200 W
PSU/1HU-R-DC-200 DC-input power supply unit for a 1HU shelf with rear power access;
It delivers a maximum output power of 200 W
PSU/7HU-AC AC power supply unit for a 7HU Shelf
PSU/7HU-AC-800 AC power supply unit for a 7HU Shelf and 9HU Shelf; 800W output
power are needed for operation in the shelf
PSU/7HU-DC DC power supply unit for a 7HU Shelf
PSU/7HU-R-DC DC power supply unit for a 7HU Shelf rear power access
PSU/7HU-AC-HP High-Power AC Power Supply Unit for a 7HU Shelf and 9HU Shelf with
front power access
R
R receive
RADIUS Remote Authentication Dial-In User Service
RAM random access memory
RAMAN-C10 C-band Distributed Fiber Raman Amplifier with constant pump
power, which provides up to 10 dB of Raman gain in a G.652
fiber.
RCVCLK receiver clock failure (loss of clock)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFW single-fiber working
SGEO-RATE supporting entity outage alarm - data rate not supported
SH1HU-F/2DC 1HU Shelf equipped with a DC power supply unit and dual front
access power feeds
SH1HU-HP/2DC 1HU Shelf High Power equipped with a DC-input power supply
unit and dual front access power feeds; It is intended for
applications requiring higher wattage and cooling airflow rates.
SH1HU-HP/E-TEMP/2DC 1HU Shelf High Power equipped with a DC-input power supply
unit and dual front access power feeds; It is intended for
extended low ambient temperature operation and applications
requiring higher wattage and cooling airflow rates.
SH1HU-R 1HU Shelf Rear Power Access
SH1HU-R/PF 1HU Shelf Rear Power Access equipped with a pluggable fan
unit, an replaceable air filter and redundant AC power supply
SH1HU/PASSIVE/FT 1HU Passive Shelf with fiber tray
SH7HU 7HU Shelf
SH7HU-R 7HU Shelf rear power access
SH9HU 9HU Shelf
SNMP simple network management protocol
SONET synchronous optical network
SQM loss of sequence
SSF server signal fail
SSH secure shell protocol
SSMF standard single-mode fiber
T
T transmit
TCA access type TDM channel module
threshold crossing alert
TCC core type TDM channel module
TCE enterprise type TDM channel module
TCM tandem correction monitoring
TCP transmission control protocol
TDM time division multiplexing
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
U
UAS unavailable seconds
UBE uncorrected block errors
ULL Ultra Low Loss fiber
UNEQ unequipped
UNI User Network Interface (is a demarcation point between the
responsibility of the service provider and the responsibility of the
subscriber)
USB universal serial bus
UTC universal time coordinated
UTM Utility Module
W
W (1) width
(2) watt (SI derived unit of power – a term that refers to power
produced as electricity)
WAN wide area network
WCA WDM channel module access type
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
WCA-PCN-2G5U access type 2.5G WDM channel module with a single client and
dual network pluggable interfaces
WCC core type WDM channel module
WCC-PC1N-2G7U core type 2.7G WDM channel module with a pluggable client and
network port.
Both ports are designed for the support of intra office, standard and
long reach as well for the support of CWDM long and very long
reach and DWDM very long and ultra-long reach
WCC-PCTN-10G-LN#DC core type WDM channel module with a pluggable interface on the
client side and a single tunable integrated long reach DWDM
interface on the network side; maximum client and network data
rate of 11.0957 Gbit/s (#DC stands for one of 81 DWDM channels in
the C and L band at 50 GHz)
WCC-PCTN-10G-V#DC core type 10G WDM channel module with pluggable client interface
and integrated, very long reach link distance, tunable DWDM
network interface; maximum client and network data rate of 11.0957
Gbit/s (#DC stands for one of 81 DWDM channels in the C band at
50 GHz according to ITU-T G.694.1.)
WCC-PCTN-10G-V#DL core type 10G WDM channel module with pluggable client interface
and integrated, very long reach link distance, tunable DWDM
network interface; maximum client and network data rate of 11.0957
Gbit/s (#DL stands for one of 41 DWDM channels in the L band at
100 GHz according to ITU-T G.694.1.)
X
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Y
y-cable/MM 3-port multimode fiber-optic cable with an integrated 50/50 coupler on
the common end to facilitate channel card protection.
y-cable/SM 3-port single-mode fiber-optic cable with an integrated 50/50 coupler
on the common end to facilitate channel card protection.
Introduction
This chapter provides an overview of the wavelengths used for the Fiber Service
Platform (FSP 3000R7) and gives information about the defined operating
network wavelengths, FEC codes, equipment disposal, power consumption
values, conformance of laser products and EMC classification.
Wavelength Plan
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
While the system allows the use of any of the values listed in the table
below on input, it is recommended that when specifying the value of
DWDM channel attributes, the numeric form (e.g. 19200) be used.
This format provides a consistent specification format for the input
PS
DWDM Wavelengths
Table 1 and Table 2 are subsets of the ITU-T 694.1 (DWDM) as used by the
FSP 3000R7 system.
"Even" channels refer to the channels with frequencies of 196.00 THz to 192.00
THz with a spacing of 100 GHz. “Odd” channels refer to the channels with
frequencies of 195.95 THz to 192.05 THz with a spacing of 100 GHz as well.
The channel with the frequency of 196.00 THz is available for fixed banded filter
modules only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
195.20 1535.82 #D08 19520
195.15 1536.22 19515
195.10 1536.61 #DC2 19510
195.05 1537.00 19505
195.00 1537.40 #D09 19500
194.95 1537.79 19495
194.90 1538.19 #D10 19490 5
194.85 1538.58 19485
194.80 1538.98 #D11 19480 E05
194.75 1539.37 19475
194.70 1539.77 #D12 19470 6
194.65 1540.16 19465
194.60 1540.56 #DC3 19460 E06
194.55 1540.95 19455
194.50 1541.35 #D13 19450 7
194.45 1541.75 19445
194.40 1542.14 #D14 19440 E07
194.35 1542.54 19435
194.30 1542.94 #D15 19430 8
194.25 1543.33 19425
194.20 1543.73 #D16 19420 E08
194.15 1544.13 19415
194.10 1544.53 #DC4 19410
194.05 1544.92 19405
Modules / transceivers supporting the 100GHz channel grid in the C Band with
41 channels offer channel frequencies from 196.00 THz to 192.00 THz.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Modules / transceivers supporting the 50GHz channel grid in the C Band with 81
channels offer channel frequencies from 196.00 THz to 192.00 THz.
Modules / transceivers supporting the 50GHz channel grid in the C Band with 96
channels offer channel frequencies from 196.00 THz to 191.25 THz.
Table 2 contains the DWDM L-band wavelengths used by the FSP 3000R7.
CWDM Wavelengths
Table 3 contains the CWDM wavelengths according to ITU-T 694.2 and channel
names used by the FSP 3000R7.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
specification of the respective channel module or to Appendix A: DWDM
Modules - Channel Grid Support.
The receiver sensitivity of CWDM and DWDM interfaces is given for the
respective transmitter wavelength range. These receivers, excepting the
modules supporting 40G and 100G, can operate with 1310 nm grey signals as
well. In this case the receiver sensitivity may be reduced by up to 2 dB.
The receivers of client interfaces with 1310 nm transmitter can operate with
CWDM or DWDM data signals as well even if not specified. If the specified
receiver wavelength range does not cover the C band and/or L band the
receiver sensitivity may be reduced by up to 2 dB.
850 nm grey interfaces cannot operate with 1310 nm, CWDM or DWDM signals
and vice versa.
FEC Codes
Depending on the type of channel module the following forward error correction
codes are used by the FSP 3000R7 system:
Table 4: FEC Codes
FEC Code Equipment Type
GFEC, Reed-Solomon (255,239) FEC WCC40GT, 4TCC40GT,
code according to ITU-T G.709 WCC10GT-D, 4TCC10GT,
(Annex A) 2TWCC2G7, WCC2G7,
2WCC10G, WCC100GT-D
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
10TCC10GT, 10TCCS10GT,
5TCE10GT, 5TCE10GTAES,
5TCE10G, 5TCE10GAES,
10TCC10G, 10TCE100G1
EFEC-1, Super FEC Code according 4TCC10GT
to ITU-T G.975.1 I.7
EFEC-2, Super FEC Code according WCC10GT, 10TCC10GT,
to ITU-T G.975.1 I.4 10TCCS10GT, 2WCC10G,
10TCC10G
EFEC-3, Super FEC Code according WCC40GT, 4TCC40GT
to ITU-T G.975.1 I.6
EFEC-4, proprietary Turbo-Product WCC100GT-D
Code based soft-decision FEC (WCC-PCTN-100GA)
(providing 11.2 dB net coding gain)
EFEC-5, proprietary Super FEC with 10TCE100G2, WCE100G,
configurable coding gain WCE100GB, 10TCE100GAES
EFEC-6, proprietary Turbo-Product WCC100GT-D
Code based soft-decision FEC (WCC-PCTN-100GB)
(providing 11.2 dB net coding gain)
1. GFEC only supported on the 10TCE-PCN-10G+100G-GF
2. EFEC-5 only supported on the 10TCE-PCN-10G+100G
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
20 if node contains SCU-II deployed in a
protected ring topology
26 if node controlled by NCU-II or NCU-II-P
(may be limited to 20 by shelf ID range)
Compliance Statements
The FSP 3000R7 product family has to comply with EMC, product safety, laser
safety and product marking standards. An overview of the standards applied to
the FSP 3000R7 product family can be found the in the following subsections.
refer to the Planning and Engineering Guide and Safety Guide for
allowed configurations.
Note
International
Table below lists EMC, product and laser safety standards valid for international
users. Further information can be found in the Safety Guide.
European Union
Table below lists EMC, product and laser safety standards valid for european
users. Further information can be found in the Safety Guide.
EN 50419:2006
RoHS directive 2011/65/EU (ROHS),
EN 50581:2012
1. Certified as a Class 1M laser product with hazard level 1M.
The FSP 3000R7 supplied to the community market for the first time meets the
standards valid in the european union.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
STM-256
OC-3, OC-12, • Telcordia GR-253, GR-1377,
OC-48, OC-192,
• ANSI T1.101, T1.105.03
OC-768
OTU1, OTU2, • ITU-T recommendations G.709, G.8251,
OTU3, OTU4
• ITU-T recommendation O.173
1 GbE • IEEE 802.3 Clause 38 formerly (IEEE 802.3z)
10 GbE • IEEE 802.3ae 2002, IEEE 802.3ap 2007
40 GbE, 100 • IEEE P802.3ba/D0.9, 25th Aug 200:
GbE LR4
• Draft P802.3ba/D3.11 16th Mar 2010
100 GbE SR10, • IEEE 802.3 2012, subclauses 86.7.3, 86.8.2, 86.8.4,
LR10 86.8.3.3
Environmental Conditions
The FSP 3000R7 product family fulfills several environmental conditions
(ambient temperatures and relative humidity levels) for storage, transportation
and stationary operation of the equipment. These environmental conditions are
specified in:
• Telcordia GR-63-CORE, Issue 4, April 2012 (Telcordia SR-3580:2012 level
3 (NEBS))
• ETSI EN 300 019-1-1 V2.1.8 (2013-12) Storage Class 1.2
specifications.
Note
360 hours in any given year, but no more than 15 occurrences during
Note that 1-year period.)
These minimum and maximum values of temperature and humidity are not met
simultaneously.
All specifications in this document are valid for end of life and over the
PS
Power Consumption
The Power Consumption values given in this document for all modules are
worst case. They are valid for end of life and over the whole temperature range.
Channel modules may be equipped with DWDM pluggable transceivers on the
network ports and CWDM or DWDM pluggable transceivers on the client ports
(where applicable).
For channel modules and amplifiers typical power consumption values are
stated. These values are given for end of life and room temperature (25°C).
Channel modules may be equipped with DWDM pluggable transceivers on the
network ports and grey pluggable transceivers on the client ports (where
applicable).
Attenuator
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Module delay of a pluggable transceiver is the sum of delays which are caused
by the optical-electrical conversion of the receiver and the electrical-optical
conversion of the transmitter.
Figure 2 illustrates the module delay of pluggable transceivers.
Latency
Latency of an optical filter module is the measured time to transmit the data
signal from the multiplexer ingress port to the multiplexer egress port or from the
demultiplexer ingress port to the demultiplexer egress port.
Figure 3 illustrates the latency of optical filter modules.
Cx‐M Cx‐D
N‐M N‐D
Latency Latency
Time for passing Time for passing
through the data through the data
signal from signal from
multiplexer ingress demultiplexer ingress
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
port to multiplexer port to demultiplexer
egress port egress port
“PSU/9HU-AC” on p. 75
“FAN/9HU” on p. 78
“CEM/9HU” on p. 79
“SH7HU” on p. 82
“SH7HU-R” on p. 84
“PSU/7HU-DC” on p. 86
“PSU/7HU-AC” on p. 88
“PSU/7HU-DC-HP” on p. 90
“PSU/7HU-AC-HP” on p. 92
“PSU/7HU-R-DC” on p. 94
“PSU/7HU-R-DC-HP” on p. 96
“PSU/7HU-AC-800” on p. 98
“FAN/Plug-In” on p. 101
“SH1HU-HP/2DC” on p. 103
“SH1HU-HP/E-TEMP/2DC” on p. 106
“SH1HU-F/2DC” on p. 111
“SH1HU-R” on p. 113
“SH1HU-R/PF” on p. 115
“PSU/1HU-R-AC” on p. 117
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SH9HU
The 9HU Shelf (SH9HU) features 22 slots. Slots 1 through 20 are 4 HP wide
and 5 HU high. Slots A and B are the two leftmost slots. They are half the height
of all other slots. These slots are predetermined for the Shelf Control Unit (SCU
and SCU-II) and Network Element Control Unit (NCU-II). Instead of installing an
NCU-II into slot A, two NCU-II-P modules can be installed into the shelf. The two
NCU-II-P modules are used to protect against communication failures. These
modules are full-height modules and have to be placed into slot 3 and 18.
Please note: The installation of a NCU-II-P always requires the installation of a
second standby NCU-II-P in the same shelf. If only one NCU-II-P is installed, an
alarm will be generated.
The power supply units have to be plugged in the slots 1 and 2 or 19 and 20 (or
both). All other modules of the FSP 3000R7 can be plugged anywhere in slots 3
through 18.
supported.
Note
PS
• using NCU-II together with NCU-II-P
Note • using NCU-II-P together with SCU/SCU-S
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Max. weight with three FAN/9HUs approx. 32 kg (70 lbs)
and a CEM/9HU, all slots are fully
populated
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
GR-63, Issue 4:2012 NEBS Use of supplied NEBS-KIT/9HU
requirement required
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 1,204,268 h
Number of half size slots 2
Number of full size slots 20
Power supply (two fully redundant PSU/9HU-DC, PSU/9HU-AC,
power supplies possible) PSU/7HU-AC-HP, PSU/7HU-AC-800
Fan 3 x FAN/9HU
Applicable management modules NCU-II, NCU-II-P, SCU, SCU-II
PSU/9HU-DC
The PSU/9HU-DC is a two slot, plug-in DC power supply unit specifically
designed for a 9HU Shelf (SH9HU). Up to two power supplies can be installed
into the shelf. If two power supplies are installed load sharing and redundancy
are supported. As opposed to the PSU/7HU-DC the PSU/9HU-DC has no DC
power terminal on the faceplate. The DC power terminals are located on the
SH9HU. A mix of one PSU/9HU-AC and one PSU/9HU-DC per shelf is
permitted.
SH9HU Shelf does not exceed the maximum output power of the
Note PSU/9HU-DC.
The following tables provide information about fault monitoring of the module.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Alarm clear interval (undervoltage) 34 V to 37 V
Turn off undervoltage interval 30 VAC to 34 VAC
Turn on undervoltage interval 31.5 VAC to 35.9 VAC
PSU/9HU-AC
The PSU/9HU-AC is a two slot, plug-in AC power supply unit specifically
designed for the 9HU Shelf (SH9HU). Up to two power supplies can be installed
into the shelf. If two power supplies are installed load sharing and redundancy
are supported. A mix of one PSU/9HU-AC and one PSU/9HU-DC per shelf is
permitted.
Width 8 HP
Height 5 HU
Weight 1.65 kg (3.6 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1e
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 381,274 h
Slot positions SH9HU: 1+2 and 19+20
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
circuit.) 240 VAC
Input
AC-input type Autoranging input
Rated input voltage 100 V to 240 V AC
Input voltage range 90 V to 264 V AC
Input frequency 47 Hz to 63 Hz
Active PFC > 0.97 (pursuant to EN 61000-3-2).
Measured at 100/230 Vac, rated laod.
Maximum input current 12.5 A at 100 V AC full load and
5.4 A at 230 V AC full load
Rated input current 11.8 A at 100 V AC full load and
5.4 A at 240 V AC full load
Inrush current (1 ms after power on) <38 A at 264 V AC
Power
Typical power consumption 1110 W
Maximum power consumption 1160 W
under worst case conditions
Standby power consumption 5 W at 100 -127 VAC
4 W at 220 -240 VAC
Output
Nominal output voltage 12.2 V (+/- 2.5%)
Minimum output current 0A
Maximum output current 82.0 A at 12.2 V
The efficiency values meet the requirements of the 80PLUS® Energy Star
class: “Gold”
Table 20 provides information about fault monitoring input for the PSU/9HU-AC.
FAN/9HU
The FAN/9HU for the SH9HU is a plug-in unit located above the module slots
and the CEM/9HU. Three of these fans are required to operate a 9HU Shelf.
Each of them is individually replaceable. A hinged handle on the front of the
panel supports an easy remove. The FAN/9HU are speed controlled fans which
exhaust the air from all slots for cooling of the FSP 3000R7 modules. They are
attached directly to the backplane with a backplane connector and are fed by
the power supplies of the shelf. A controller module allows access from the
management system. The front panel of the FAN/9HU unit has one status LED.
Table 23 contains general information about the FAN/Plug-In and its
environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Air filter pad replacement intervals A dirty air filter pad negatively
influences cooling efficiency. Taking air
pollution into consideration, replace
dirty air filter pads at least once a year.
ADVA Optical Networking strongly
recommends replacing the air filter pad
every 90 days.
Typ. power consumption 9 W (full loaded shelf and 27°C ambient
temperature)
Max. power consumption 56 W
MTBF at 25°C ambient temperature 7,345,159 h
Slot positions slot above the CEM/9HU
Mean time to replace < 1 min
CEM/9HU
The CEM/9HU (Common Equipment Module for the 9HU Shelf) is a plug-in unit.
It is located between the module slots and the FAN/9HU in an SH9HU shelf.
The CEM/9HU includes the Fan Control Unit (FCU), LED signaling and
alarm-LED control, LCD and foil pushbuttons. It provides the combined
functionality of the PSCU (4 ports) and the UTM (3 x RJ45 + 16 x In + 4 x Out).
One CEM/9HU is required per 9HU Shelf.
The front panel of the CEM/9HU has the following LEDs:
• Network Element alarm status LEDs
• Module status LED
• Slot status LEDs for slots A, B, 1 to 20
• Telemetry port LEDs 1 - 20
• Interconnect port LEDs 1 - 4
• Ethernet port LAN LEDs 1 - 3
In addition the shelf number can be set via push buttons to be displayed on the
front panel.
Table 26 shows general information about the CEM/9HU and its environment.
The following table shows information about telemetry alarm input parameters.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
alarm if the contact is closed or opened.
The following table contains information about the hardware reset possibility.
SH7HU
The 7HU Shelf (SH7HU) features 22 slots. Slots 1 through 20 are 4 HP wide
and 5 HU high. Slots A and B are the two leftmost slots. They are half the height
of all other slots. These slots are predetermined for the Shelf Control Unit
(SCU/SCU-II) and Network Element Control Unit (NCU, NCU-II). All other
modules of the FSP 3000R7 system can be plugged in anywhere in slots 1
through 20.
The SH7HU can be equipped with the following management modules:
• Network Element Control Unit (NCU, NCU-II in slot A)
• Shelf Control Unit
o
SCU in slot B
o
SCU-II in slot B
o
SCU-II in slot A and B for redundant configurations but only in the main
shelves
An FSP 3000R7 shelf is called:
• master shelf if it is equipped with one NCU/NCU-II and one SCU/SCU-II
• main shelf if it is equipped with one SCU/SCU-II
• main shelf if it is equipped with two SCU-II modules only (for redundant
SCU configurations)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
For redundant SCU-II configurations in an SH7HU main shelf it is
PS
SH7HU-R
The SH7HU-R Shelf features 22 slots. The slots 1 through 20 are 4 HP wide and
5 HU high. The two slots most left are of half size height and named A and B.
These slots are predetermined for the Shelf Control Unit (SCU/SCU-II) and
Network Control Unit (NCU/NCU-II). All other modules of the FSP system with
except of the PSU/7HU-R-DC and PSU/7HU-R-DC-HP can be plugged in
anywhere in slots 1 through 20. The PSU/7HU-R-DC and PSU/7HU-R-DC-HP
have to be installed in slot 1+2 and 19+20.
PS
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• master shelf if it is equipped with one NCU/NCU-II and one SCU/SCU-II
only (for non-redundant configurations)
• main shelf if it is equipped with one SCU/SCU-II only (for non-redundant
configurations)
• main shelf if it is equipped with two SCU-II modules only (for redundant
SCU configurations)
PSU/7HU-DC
The PSU/7HU-DC is a two slot, plug-in DC power supply unit specifically
designed for a 7HU Shelf. Up to two power supplies can be installed into the
shelf. If two power supplies are installed load sharing and redundancy are
supported. For power feeding, the power supply unit has a terminal block on its
faceplate.
SH7HU Shelf does not exceed the maximum output power of the
Note PSU/7HU-DC.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient 531,166 h
temperature
Maximum RAM consumption on 29 Kbytes
NCU
Slot positions SH7HU: 1+2 and 19+20
PSU/7HU-AC
The PSU/7HU-AC is a two slot, plug-in AC power supply unit specifically
designed for a 7HU Shelf. Up to two power supplies can be installed into the
shelf. If two power supplies are installed load sharing and redundancy are
supported. For power feeding, the power supply unit has an AC appliance
coupler on its faceplate.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Width 8 HP
Height 5 HU
Weight 1.3 kg (2.9 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 517,131 h
Maximum RAM consumption on 26 Kbytes
NCU
Slot positions SH7HU, SH7HU-R: 1+2 and 19+20
PSU/7HU-DC-HP
The PSU/7HU-DC-HP is a two slot, plug-in high power DC power supply unit
specifically designed for a 7HU Shelf. Up to two power supplies can be installed
into the shelf. If two power supplies are installed load sharing and redundancy
are supported. For power feeding, the power supply unit has a terminal block on
its faceplate.
SH7HU Shelf does not exceed the maximum output power of the
Note PSU/7HU-DC-HP.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient 483,325 h
temperature
Maximum RAM consumption on 29 Kbytes
NCU
Slot positions SH7HU: 1+2 and 19+20
The following table lists all electrical specifications concerning this module.
PSU/7HU-AC-HP
The PSU/7HU-AC-HP is a two slot, plug-in high power AC power supply unit
specifically designed for a 7HU Shelf and 9HU Shelf. Up to two power supplies
can be installed into the shelf. If two power supplies are installed load sharing
and redundancy are supported. For power feeding, the power supply unit has an
AC appliance coupler on its faceplate.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Width 8 HP
Height 5 HU
Weight 1.5 kg (3.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 467,727 h
Maximum RAM consumption on 26 Kbytes
NCU
Slot positions SH7HU, SH7HU-R, SH9HU: 1+2 and
19+20
circuit.)
Input voltage 100 V to 240 V AC (+/- 10%)
Frequency 50 Hz to 60 Hz
Rated input current range 7.2 A to 3 A
Inrush current (1 ms after power on) 7.5 A
Nominal power consumption 720 W
Max. power consumption under worst 730 W
case conditions
Max. output power 600 W
Nominal output voltage 12.2 V
Max. output current 50 A
PSU/7HU-R-DC
The PSU/7HU-R-DC is a plug-in DC power supply unit specifically designed for
an SH7HU-R Shelf. Up to two power supplies can be installed into the shelf. If
two power supplies are installed load sharing and redundancy are supported.
This power supply has no terminal block on its faceplate. For power feeding, the
3-pin input power connector of the unit connects to the corresponding connector
on the backplane. This connector is electrically linked with the external terminal
block at the rear of the shelf.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Width 8 HP
Height 5 HU
Weight 1.3 kg (2.9 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS)
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient 827,130 h
temperature
Maximum RAM consumption on 29 Kbytes
NCU
Slot positions SH7HU-R: 1+2 and 19+20
PSU/7HU-R-DC-HP
The PSU/7HU-R-DC-HP is a plug-in high power DC power supply unit
specifically designed for an SH7HU-R Shelf. Up to two power supplies can be
installed into the shelf. If two power supplies are installed load sharing and
redundancy are supported.
This power supply has no terminal block on its faceplate. For power feeding, the
3-pin input power connector of the unit connects to the corresponding connector
on the backplane. This connector is electrically linked with the external terminal
block at the rear of the shelf.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Width 8 HP
Height 5 HU
Weight 1.5 kg (3.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS)
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 483,325 h
Maximum RAM consumption on 29 Kbytes
NCU
Slot positions SH7HU-R: 1+2 and 19+20
The following table lists all electrical specifications concerning this module.
PSU/7HU-AC-800
The PSU/7HU-AC-800 is a two slot, plug-in AC power supply unit specifically
designed for an SH7HU/SH7HU-R Shelf. It can also be used by an SH9HU
Shelf. Up to two power supplies can be installed into the shelf. If two power
supplies are installed load sharing and redundancy are supported. For power
feeding the power supply unit has an AC appliance coupler on its faceplate.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
First release 11.1
Width 8 HP
Height 5 HU
Weight 1.5 kg (3.3 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient 403,197 h
temperature
Maximum RAM consumption on 26 Kbytes
NCU
Slot positions SH7HU, SH7HU-R: 1+2 and 19+20
SH9HU: 1+2 and 19+20
The following tables provide information about fault monitoring of the module.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FAN/Plug-In
The FAN/Plug-In for the SH7HU and SH7HU-R is a plug-in module located atop
the slots. It has three speed controlled fans which exhaust the air from all slots
for cooling of the FSP 3000R7 modules. It is attached directly to the backplane
with a backplane connector and is fed by the power supplies of the shelf. A
controller module allows access from the management system.
The front panel of the FAN/Plug-In unit has the following LEDs:
• Network Element status LEDs
• Fan status LED (fan)
• Slot status LEDs for slots A,B, 1 to 20
In addition the shelf number can be set via push buttons to be displayed on the
front panel.
Table below contains general information about the FAN/Plug-In and its
environment.
The failure of a single fan does not endanger the cooling of the
modules in the shelf up to 45°C ambient temperature. However,
PS
the whole plug-in fan unit should be replaced by Service
Personnel at the earliest opportunity. If two fans fail, the plug-in
Note
fan unit should be replaced within 48 hours after fan failure.
This table gives information about the available push buttons of the
FAN/Plug-In.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SH1HU-HP/2DC
The SH1HU-HP/2DC (1HU Shelf High Power with redundant DC PSU) is a
rack-mountable, 1 HU-high, DC-powered shelf, which includes an entire
FSP 3000R7 system. The internal power supply is integrated on the left side.
Six individual fans ensure the effective cooling of the modules. The
SH1HU-HP/2DC shelf provides an increased power output and a large increase
in airflow. This is required for using 10PCA-PCN-1G3+10G modules.
The SH1HU-HP/2DC shelf features 4 slots. Slots 1 and 2 are 4 HP wide and 5
HU high. The remaining two slots are half the height of the other slots and
named A and B. These slots are predetermined for the SCU/SCU-S/SCU-II and
NCU-II/NCU. All other modules of the FSP 3000R7 system can be plugged in
anywhere in slots 1 and 2.
The SH1HU-HP/2DC can be equipped with the following management modules:
• Network Element Control Unit (NCU-II/NCU in slot A)
• Shelf Control Unit
o
SCU/SCU-S in slot B
o
SCU-II in slot B
An FSP 3000R7 shelf is called:
• master shelf if it is equipped with one NCU-II/NCU and one
SCU/SCU-S/SCU-II
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table lists all electrical specifications concerning this shelf.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 68: Shelf Monitoring
Digital monitoring input voltage alarm
Fan fail
Temperature module temperature in °C
The following tables provide information about fan data, indicators and
operating elements.
SH1HU-HP/E-TEMP/2DC
The SH1HU-HP/E-TEMP/2DC is a rack-mountable, DC-powered 1 HU Shelf
High Power with dual front access power feeds. This shelf is based on the
design of the SH1HU-HP/2DC. It is primarly intended for extended low ambient
temperature operation and applications requiring higher wattage and cooling
airflow rates.
The SH1HU-HP/E-TEMP/2DC includes an entire FSP 3000R7 system. The
internal DC-input power supply is integrated on the left side. Six individual fans
ensure the effective cooling of the modules. The fans cannot be swapped. This
shelf has a built-in temperature control in order to keep the operating
temperatures for the equipped modules within the working range at ambient
temperatures down to -33°C. Therefore modules, which are used within this
shelf can be operated down to -33°C ambient temperature, independent of their
environmental temperature specification. The upper temperature limits of the
modules remain still valid.
After power fail the shelf will establish an internal temperature towards the
specified working temperature for the equipped modules and is then powering
up the modules.
The SH1HU-HP/E-TEMP/2DC shelf features 4 slots. Slots 1 and 2 are 4 HP
wide and 5 HU high. The remaining two slots are half the height of the other
slots and named A and B. These slots are predetermined for the SCU-S and
NCU-II. All other modules of the FSP 3000R7 system can be plugged anywhere
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
in slots 1 and 2.
The SH1HU-HP/E-TEMP/2DC can be equipped with the following management
modules:
• Network Element Control Unit (NCU-II only) in slot A
• Shelf Control Unit (SCU-S only) in slot B
An FSP 3000R7 shelf is called:
• master shelf if it is equipped with one NCU-II and one SCU-S
• main shelf if it is equipped with one SCU-S only
Table 72 provides general information about the shelf and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
50% load tbd
20% load tbd
The efficiency values meet the requirements of the 80PLUS® Energy Star
class: “Platinum”.
Table 76 provides information about power-up modes.
Table 77 provides information about fault monitoring input and protection for the
SH1HU-HP/E-TEMP/2DC.
Table
‘s 80: Indicators
Seven-segments digital display 28 mm x 13 mm, used for Shelf ID
(1 to 20, 1E to 20E)
Network Element status LEDs (only Critical (red), Major (yellow)
used in master shelf with NCU) Minor (yellow)
Slot status LEDs for slots A, B, 1, 2 one for each of the 4 slots to visualize
slot status
Fan status LED to visualize fan status
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SH1HU-F/2DC
The SH1HU-F/2DC features 4 slots. Slots 1 and 2 are 4 HP wide and 5 HU high.
The remaining two slots are of half size height and named A and B. These slots
are predetermined for the Shelf Control Unit (SCU/SCU-S/SCU-II) and Network
Element Control Unit (NCU/NCU-II). All other modules of the FSP 3000R7
system can be plugged in anywhere in slots 1 and 2.
The SH1HU-F/2DC can be equipped with the following management modules:
• Network Element Control Unit (NCU/NCU-II in slot A)
• Shelf Control Unit
o
SCU/SCU-S in slot B
o
SCU-II in slot B
An FSP 3000R7 shelf is called:
• master shelf if it is equipped with one NCU/NCU-II and one
SCU/SCU-S/SCU-II
• main shelf if it is equipped with one SCU/SCU-S/SCU-II only
The following table shows general information about the shelf and its
environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Fan fail
Temperature module temperature in °C
The following tables provide information about fan data, indicators and
operating elements.
SH1HU-R
The SH1HU-R of the FSP 3000R7 features 6 slots. The slots 1 and 2 are 4 HP
wide and 5 HU high. The neighboring two slots are of half size height and
named A and B. These slots are predetermined for the Shelf Control Unit
(SCU/SCU-S/SCU-II) and Network Element Control Unit (NCU/NCU-II). The
remaining two slots are dedicated AC power supply modules located in the rear
side. All other modules of the FSP 3000R7 system can be plugged in anywhere
in slots 1 and 2.
The SH1HU-R can be equipped with the following management modules:
• Network Element Control Unit (NCU-II/NCU in slot A)
• Shelf Control Unit
o
SCU/SCU-S in slot B
o
SCU-II in slot B
An FSP 3000R7 shelf is called:
• master shelf if it is equipped with one NCU-II/NCU and one
SCU/SCU-S/SCU-II
• main shelf if it is equipped with one SCU/SCU-S/SCU-II only
The following table shows general information about the shelf and its
environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table contains information about the available indicators of the
shelf.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Display three 7-segment LEDs used for Shelf
ID (1 to 20, 1E to 20E)
Network Element status LEDs Critical (red), Major (yellow),
(only used in master shelf with NCU) Minor (yellow)
Slot status LEDs for slots A, B, 1, 2 one for each of the 4 slots to visualize
slot status
Fan status LED to visualize fan status
Power status LEDs for "pwr1" and to visualize AC power status
"pwr2"
The following table shows the available push buttons of the shelf.
SH1HU-R/PF
The SH1HU-R/PF is a rack-mountable, rear power access 1HU Shelf equipped
with a pluggable fan module, a replaceable air intake filter and redundant AC
power supplies. The shelf can be used to house any FSP 3000R7 modules. The
SH1HU-R/PF features four horizontal slots accessible from the front for
accommodating standard FSP 3000R7 modules, two half height ones for
housing management modules and two full height ones for housing traffic
modules.
The shelf also has an air filter unit which is made up of a fixed filter guide frame
and a removable frame which contains the air filter pad. The air filter guide
frame ensures sufficient space for fiber management from below (for slot 1) or
above (for slot 2) the air filter frame.
The assignment of NCU and SCU type modules to the A and B slots
of this shelf are the reverse of all other 1HU Shelf types, due to the
PS
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 94: Shelf Monitoring
Digital monitoring input voltage alarm
Fan fail
Temperature module temperature in °C1
1. is equivalent to the air exhaust temperature (in °C)
Table below contains information about the available indicators of the shelf.
The following table shows the available push buttons of the shelf.
PSU/1HU-R-AC
The Power Supply (PSU/1HU-R-AC) provides the power needed to operate an
SH1HU-R shelf. Up to two power supplies can be installed into the shelf. If two
power supplies are installed load sharing and redundancy are supported.
The following table contains general information about the PSU/1HU-R-AC and
its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Rated input current 1.8 A at 100 VAC
0.7 A at 240 VAC
Inrush current < 15 A, < 5 ms
Nominal power consumption 165 W
Max. power consumption under 170 W
worst case conditions
Max. output power 120 W
Nominal output voltage 12.2 V
Max. output current 10 A
The following tables provide information about fault monitoring of the module.
PSU/1HU-R-AC-200
The Power Supply (PSU/1HU-R-AC-200) provides the power needed to operate
an SH1HU-R/PF shelf. Up to two power supplies can be installed into the shelf.
If two power supplies are installed load sharing and redundancy are supported.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Depth (including connectors and handles) 165 mm (6.5”)
Weight 1.2 kg (2.8 lbs)
Degree of protection according to IEC IP20. Use in a pollution degree 2
60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 634,456 h
Slot positions PSU1 and/or PSU2 slot on rear
side of the SH1HU-R/PF
The following tables provide information about fault monitoring of the module.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
PSU/1HU-R-DC-200
The PSU/1HU-R-DC-200 is a plug-in 200-W DC-input power supply unit specifi-
cally designed for the SH1HU-R/PF shelf. Up to two power supplies can be
installed into the shelf. If two power supplies are installed load sharing and
redundancy are supported. Permanent mixed operation is supported with the
PSU/1HU-R-AC-200 per shelf.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
by ADVA Optical Networking is
mandatory. See Table 110.
Input
DC Input connector male 3-pin Dinkle power connector
(Plus, Minus, PE) on the front panel
Rated input voltage -48 V DC
Input voltage range -36 V to 72 V DC
Rated input current range < 6.25 A to 3.2 A
Maximum input current < 6.6 A at 36 V, full load
Inrush current (0.1 ms after power < 10 A at 72 V, cool and warm status
on)
Power
Typical power consumption 215 W
Max. power consumption under 220 W
worst case conditions
Standby power consumption 5W
Output
Nominal output voltage 12.2 V (+/- 0.2 % initial set point)
Minimum output current 0A
Max. output current 16.4 A (voltage can drop to 11.9 V at
full load
Max. output power 200 W
Minimum hold-up time 10 ms
The efficiency values meet the requirements of the 80PLUS® Energy Star
class: “Platinum”.
FAN/1HU
The FAN/1HU is a plug-in fan module specifically designed for the SH1HU-R/PF
shelf. The module consists of three high-power fans to generate sufficient air
flow for module cooling. Each fan is supplied separately and operates
independently of one another. The fans are powered using a common
backplane connector.
The FAN/1HU module can only be installed in the left most slot of the
SH1HU-R/PF shelf. This slot is covered by the display panel during normal
operation. The fan module has a single tri-color LED labeled "Fan" on the front
panel of the SH1HU-R/PF shelf to indicate the different operating states of the
three fans.
Table below contains general information about the FAN/1HU and its
environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
IEC 60529 environment and indoor controlled
office environments only.
Typ. power consumption 1.5 W (25°C ambient temperature)
Max. power consumption 20.0 W
MTBF at 25°C ambient temperature 4,687,387 h
Slot position The fan unit is placed in the left most
slot and is covered by the display
panel. When the display panel is
removed the fans stop automatically
and the fan unit can be accessed
safely.
Mean time to replace < 1 min
The failure of a single fan does not affect the cooling of the
modules in the shelf up to an ambient temperature of 45°C within
PS
SH1HU/PASSIVE/FT
The SH1HU/PASSIVE/FT is a standalone, non-managed shelf with a fiber tray.
It is intended to carry passive modules, such as filters, splitters and dispersion
compensation modules. It can hold up to
• four modules with a width of 4 HP or
• two modules with a width of 4 HP and one module with a width of 8 HP or
• two modules with a width of 8 HP
The following table shows general information about the shelf and its
environment.
FMT/1HU
The FMT/1HU is a rack-mountable, 1HU-high fiber management shelf. It
includes a fiber optic tray to efficiently manage the optical fibers used within an
FSP 3000R7 system deployment. The fiber management shelf is used to
orderly maintain the fiber storage of an SH1HU, SH7HU or SH9HU shelf. Two
screws on the front side of the shelf allow access to the fiber optic tray.
The following table shows general information about the shelf and its
environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Cable capacity for 83 cables, lengths 45 to 145 cm
1,7 mm diameter cable 48 cables, lengths 146 to 240 cm
35 cables, lengths 241 to 340 cm
Weight empty 4.7 kg (10.3 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient n.a.
temperature
Power consumption n.a.
OTDR
The optical time reflectometer (OTDR) is a rack-mounted unit that combines a
test head controller (OTDR/THC/2HU/AC) unit and optical test head
(OTDR/8-OTH/1HU/AC) unit.
Placed at an installation site, the OTDR directly controls the measurements.
The OTDR/THC/2HU/AC unit has an Ethernet port for local access on the front
panel and ports on the rear panel for connecting to the OTH unit, LAN,
telephone line, and to an optional external optical switch.
The OTDR has an integrated Web application for managing fiber monitoring and
can store the data on a RAID protected hard disk.
For integration into the FSP 3000R7 system the OTDR/THC/2HU/AC has to be
connected via Ethernet LAN to NCU1.
2RAMAN-C15-LL configurations.
Note
Table 120 provides general information about the shelf and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 121: Electrical Specifications
Input connector AC Appliance Coupler
according to IEC/EN 60320
Power cord North America plug type: NEMA 5-15P, NEMA 6-20
wall plug rating: 125 VAC, 10 A
min. power cord rating: 18/3 SVT, 125
VAC, 10 A, VW-1, 105°C with L, N and
PE pin
Power cord Continental Europe plug type: CEE 7/7, CEE 7/4
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 VAC, 10 A,
HO5W-F, 105°C, 3-pole
Power cord United Kingdom plug type: BS1363
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 VAC, 10 A,
H05VV-F, 105°C, 3-pole
fuse type: 3 A, 5 A or 10 A
Power cord International plug type: according to your local and
national electrical codes with L, N and
PE pin
wall plug rating: 250 V AC, 10 A
min. power cord rating: 250 V AC, 10 A
Input voltage 100 V to 240 V AC (+/- 10%)
50 Hz to 60 Hz
Recommended external circuit min. current rating 3 A
breaker for full load conditions
Table below contains information about the available indicators of the unit.
Following table contains information about the optical connector and fiber type.
Table below contains information about the ethernet interface and cable type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Event dead zone typ: 0.8 m; max: 1 m
Attenuation dead zone typ: 4.5 m; max: 5.5 m
Linearity +/- 0.03
1. at Signal to noise ratio = 1
“10TCC-PCTN-10G+100GB” on p. 149
“WCC-PCTN-10G” on p. 159
“4TCC-PCTN-2G7+10G” on p. 170
“10TCC-PCTN-4GUS+10G” on p. 180
“10TCC-PCN-2G7US+10G” on p. 192
“10WXC-PCN-10G” on p. 202
“2WCC-PCN-10G” on p. 209
“2TWCC-PCN-2G7U” on p. 218
“WCC-PC1N-2G7U” on p. 227
WCC-PCTN-100GB
The WCC-PCTN-100GB core transponder provides transparent transport of
100GbE or OTU4 client side service in a four-slot module. The OTU4 client
interface enables Reed-Solomon (RS) FEC (GFEC) according to ITU-T G.709.
The WCC-PCTN-100GB transponder supports a limited set of physical level
fault reporting and performance monitoring of the OTU4 client interface.
Enhanced FEC (EFEC-6) at the network port enables ultra long reach perfor-
mance.
The WCC-PCTN-100GB transponder module contains a single network side
interface with an internal Dual Polarization Quadrature Phase Shift Keying
(DP-QPSK) transponder module and a single client side interface with a CFP
MSA standard compliant pluggable transceiver.
The client signal is internally mapped according to G.709 resulting in an OTU4V
signal for transport over a core optical transport network. The DWDM network
side optics with DP-QPSK modulation is tunable within the 50 GHz channel grid.
Input wavelength selection is supported by a coherent receiver.
The client side CFP performs the optical-to-electrical and electrical-to-optical
conversion function as well as collection of physical Layer PMs and Fault moni-
toring. The optical performance of the client interface is specified by the
equipped CFP module. See the selected CFP module specification for addi-
tional information.
The WCC-PCTN-100GB provides performance monitoring data at the client port
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
as well as at the network port for the physical layer, service layer, and FEC. Per-
formance monitoring data is also provided at the PCS layer for 100 GbE client
interface service.
The module supports Client Channel Card Protection (CCCP) for LR4 and LR10
CFP transceivers. CCCP for SR10 CFP transceivers is not supported.
Table 126 provides general information about the module and its environment.
Table 129 provides information about the recommended maximum client port
pre-FEC bit error ratio for (GFEC).
Table 130 provides information about the CFPs supported by the client ports.
Please refer to the Pluggable Transceiver Specifications in Chapter 6 of this
manual for individual CFP specifications.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
PMD tolerance 30 ps max.
CD tolerance -6,000 ps/nm to +60,000 ps/nm
Table 132 provides information about the bit error rate versus OSNR.
Table 132: Bit Error Rate Versus OSNR
Pre FEC bit error ratio for 1.9 x 10-2 at 13.8 dB OSNR at 0.1 nm EOL
EFEC-61 with Post FEC bit
error ratio of 10-12
1. Soft-decision FEC providing 11.2 dB net coding gain
Table 133 provides information about the recommended maximum network port
pre-FEC bit error ratio for (EFEC-6).
0
Whether fault/performance monitoring entries listed in the
PS
Table 135 provides information about fault monitoring of the module in general.
Table 136 provides information about fault monitoring of the client port in
general.
Table 137 provides information about fault monitoring of the client port in
ingress direction.
Table 138 provides information about fault monitoring of the network ports in
general.
Table 139 provides information about fault monitoring of the network ports in
egress direction.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 139: Fault Monitoring Network Interface - Egress Direction
Layer Alarm Name TL-1 Keyword
OTU4 layer OTU-Loss of Frame LOF-OTU
OTU-Loss of multiframe LOM-OTU
OTU-Loss of Lane LOL-OTU
Alignment
OTU4 layer - SM byte OTU-BDI BDI-OTU
OTU-Signal Degrade SD-OTU
OTU-TIM TIM-OTU
ODU4 layer - PM byte ODU-AIS AIS-ODU
ODU-BDI BDI-ODU
ODU-Open Connection OCI-ODU
ODU-Lock LCK-ODU
ODU-Signal Degrade SD-ODU
ODU-TIM ODU-TIM
Table 141 provides information about performance monitoring of the client ports
in ingress direction.
Table 142 provides information about performance monitoring of the client ports
in egress direction.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
(15 min/24 h records available accuracy)
for PM values except current CD Compensation CD
values; Diff Group Delay DGD
Fixed threshold crossing alerts SNR SNR
and too high available except OPT (+/- 0.5dB
SNR; accuracy) OPT
Fixed threshold crossing alerts Carrier Frequency
and too low available on OPR, Offset CFOT
CD Compensation, SNR, Carrier RX Laser Bias
Frequency Offset, OPT and Rx Current LOCL
Laser Temperature) Rx Laser
Temperature LOTEMP
Physical layer (current values) Laser Bias Current LBCL
Physical layer Laser Temperature LSRTEMP
(current values; Fixed threshold
crossing alerts and too high/too
low available)
Table 147 provides information about the link test functionality. This test
function is available on the network port only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
WCC-PCTN-100GA
The WCC-PCTN-100GA core transponder provides transparent transport of
100 GbE or OTU4 client side service in a five-slot module. The OTU4 client
interface enables Reed-Solomon (RS) FEC (GFEC) according to ITU-T G.709.
The WCC-PCTN-100GA transponder supports physical level fault reporting and
performance monitoring of the OTU4 client interface. Enhanced FEC (EFEC-4)
at the network port enables ultra long reach performance.
The WCC-PCTN-100GA transponder module contains a single network side
interface with an internal Dual Polarization Quadrature Phase Shift Keying
(DP-QPSK) transponder module and a single client side interface with a CFP
MSA standard compliant pluggable transceiver.
The client signal is internally mapped according to G.709 resulting in an OTU4V
signal for transport over a core optical transport network.The DWDM network
side optics with DP-QPSK modulation is tunable within the 50 GHz channel grid.
Input wavelength selection is supported by a coherent receiver.
The client side CFP performs the optical-to-electrical and electrical-to-optical
conversion function as well as collection of physical Layer PMs and Fault
monitoring. The optical performance of the client interface is specified by the
equipped CFP module. See the selected CFP module specification for
additional information.
The WCC-PCTN-100GA provides performance monitoring data at the client port
as well as at the network port for the physical layer, service layer and FEC.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Performance monitoring data is also provided at the PCS layer for 100 GbE
client interface service.
Table 148 contains general information about the module and its environment.
In the following the CFPs supported by the client ports. Please refer to the
specifications for the individual CFP type.
• CFP/112G/LR4/SM/LC
• CFP/112G/LR10R/SM/LC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type LC
Fiber type SM 9 µm
Type of network port Tunable DWDM interface
Data rates 120.579 Gbit/s
Protocols OTU4V
Transmitter output power range -5 dBm ... +1 dBm
Transmitter wavelength range Supports 96 C-band wavelengths on
50 GHz spacing with a tunable
interface from 1529.55 to 1567.54nm.
Wavelength stability (operating) +/- 60 pm
Max. cold startup time of controller 3 min
Max. cold startup time with new <15 min
optical link
Max. cold startup time with 3 min
unchanged optical link
Min. side mode suppression ratio 40 dB
Receiver wavelength range 1529.55 nm to 1567.52 nm
Receiver dynamic range -18 dBm to -2 dBm
Max input power 10 dBm
PMD tolerance 30 ps max.
CD tolerance -50,000 ps/nm to +50,000 ps/nm
This table provides information about the bit error rate versus OSNR.
Table 151: Bit Error Rate Versus OSNR
Pre FEC bit error ratio for 1.9 x 10-2 at 14.5 dB OSNR at 0.1 nm EOL
EFEC-41 with Post FEC bit
error ratio of 10-12
1. soft-decision FEC providing 11.2 dB net coding gain
This table shows the recommended maximum pre-FEC bit error ratio for client
port (GFEC) and network port (EFEC-4).
Max. module delay 16.3 µs for 100 GbE at the client side
22 µs for OTU4 at the client side
0
Whether fault/performance monitoring entries listed in the
PS
This table shows information about fault monitoring of the module in general.
This table shows information about fault monitoring of the client port in general.
This table shows information about fault monitoring of the client port in ingress
direction.
This table shows information about fault monitoring of the network ports in
general.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Local Oscillator degrade (Loc Osc
Bias Curr Lvl (LO Bias))
This table provides information about fault monitoring of the network ports in
egress direction.
The following table gives information about performance monitoring of the client
ports in ingress direction.
This table shows information about performance monitoring of the network ports
in general.
The following table contains information about the link test functionality. This
test function is available on the network port only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Initiate Receive Test Enable/Release status
Reset test
Test elapsed time
Error free elapsed time
Loss of sequence synchronization
Average BER during Test
Maximum BER during Test
10TCC-PCTN-10G+100GB
The 10TCC-PCTN-10G+100GB is a 100G core type four-slot TDM channel
module (muxponder) with ten small form-factor pluggable (SFP+) interfaces on
the client side and an integrated single DWDM interface on the network side.
The network interface incorporating a dual polarization quadrature phase shift
keying (DP QPSK) modulation is fully tunable over the C band at 50 GHz
channel spacing. Input wavelength selection is supported by a coherent
receiver. The client-side optics are included within the SFP+ transceiver
modules. Each of the 10 client interfaces can be configured individually to any of
the supported client services.
The 10TCC-PCTN-10G+100GB provides muxponder functionality for the
transport of 10GbE WAN, STM64/OC192, 10GbE LAN, OTU2, OTU2e and
OTU1e client services over long-haul distances. Any combination of the
supported client services is possible. The network port supports OTU4V
according to ITU-T G.709 transmitted at a data rate of 120 Gbit/s. Soft Decision
FEC (SD-FEC) Enhanced FEC (EFEC) core for OTN signals is supported on
the OTU4 network port to enable ultra long reach performance.
The 10TCC-PCTN-10G+100GB provides fault management, performance
monitoring data and alarm generation for each the client ports as well as the
network port.
Table 165 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
1310 nm type SFP+/11GU/1310S/SM/LC
CWDM type SFP+/11GU/CxxxxL/SM/LC
This table provides information about the bit error rate versus OSNR.
ratio of 10-12
Table below provides information about the mapping and multiplexing schemes.
The following table provides information about fault monitoring on the module
equipment level in general.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Temperature 2 High T-SUBTEMP-FHT
FWP-Mismatch (NSA) FWPM-NSA
FWP-Mismatch (SA) FWPM-SA
Client Port SFP+ Equipment Removed RMVD
Voltage Out of Range VOLTANR
Plug-Incompatible MEA-ACCEPT
Plug-Physical Mismatch MEA-PHYS
Plug-Not Approved MEA-APPROVE
Plug-Provision Mismatch MEA-DIFFER
Temperature High T-TEMP-FHT
Temperature Low T-TEMP-FLT
The following table provides information about fault monitoring of the client ports
in ingress direction.
The following table provides information about fault monitoring of the client ports
in egress direction.
The following table provides information about fault monitoring of the network
port in general.
This table provides information about fault monitoring of the network ports in
egress direction.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Connection Loss LTC
TIM TIM
Signal Degrade SD
BDI BDI
This table shows information about performance monitoring of the network port
in general.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
(15 min/24 h records available CD Compensation CD
for PM values except current Diff Group Delay DGD
values; SNR SNR
Fixed threshold crossing alerts OPT OPT
and too high available except Carrier Frequency
SNR; Offset CFOT
Fixed threshold crossing alerts Rx Laser Bias
and too low available on OPR, Current LOCL
CD, SNR, CFOT, OPT and Rx Laser
LOTEMP) Temperature LOTEMP
Physical layer (current values) Laser Bias Current LBCL
Physical layer Laser Temperature LSRTEMP
(current values; Fixed threshold
crossing alerts and too high/too
low available)
The following table contains information about the link test functionality. This
test function is available on the network port only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
WCC-PCTN-10G
The WCC-PCTN-10G channel module is a 10G channel module with one XFP
type pluggable client interface and one tunable DWDM network interface.
It is intended for transport of STM-64/OC-192, 10G FC, 10 GbE LAN PHY,
10 GbE WAN PHY, OTU2, OTU1e and OTU2e services. STM-64/OC-192, 10G
FC, 10 GbE LAN PHY and 10 GbE WAN PHY can be transmitted natively or,
with exception of 10G FC, can be mapped according to G.709 resulting in an
OTU2, OTU1e or OTU2e service.
GFEC can be enabled for OTU2, OTU1e and OTU2e services at both the client
port and the network port. EFEC-2 with higher coding gain is only supported on
the network port. For the support of OTU1e and OTU2e the module does not
meet the payload type standard. Only in that case OTU2e was implemented for
OTU2LAN with stuff bytes and OTU1e is used for OTU2LAN without stuff bytes.
The WCC-PCTN-10G module is available in three variants:
• WCC-PCTN-10G-LN#DC
• WCC-PCTN-10G-V#DC
• WCC-PCTN-10G-V#DL
The network ports of the WCC-PCTN-10G-LN#DC and WCC-PCTN-10G-V#DC
are fully tunable in the C band in a wavelength grid of 50 GHz. The network port
of the WCC-PCTN-10G-V#DL is fully tunable in the L band in a wavelength grid
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
of 100 GHz.
The WCC-PCTN-10G-V#DC, WCC-PCTN-10G-V#DL have very long reach
network interfaces whereas the WCC-PCTN-10G-LN#DC features a long reach
noise optimized network interface. Due to the high extinction ratio the
WCC-PCTN-10G-LN#DC is suitable for links with a large amount of amplifiers
and low OSNR.
The following table contains general information about all module variants and
their environment.
This table provides information about the client port for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ITU-T G.8262 and IEEE 1588v2
compliant transparent Ethernet
transport
Type of client ports XFP
1. STM-64 or OC-192 facility type has to be selected on the corresponding port
in the system management.
The following table provides a summary of the supported client XFPs. Please
refer to the specifications of the individual XFP type.
The following table provides information about the network port for all variants.
Table 191: Network Port - General Information for all Variants (Continued)
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s, 10.6642 Gbit/s,
10.7092 Gbit/s, 11.0491 Gbit/s,
11.0957 Gbit/s
Protocols STM-64, OC-192, 10 GbE LAN PHY,
10 GbE WAN PHY1, 10G FC, OTU2,
OTU1e (OTU2LAN without stuffing),
OTU2e (OTU2LAN with stuffing)2
Tuning time (any channel to any < 45 s
oh.)
Tuning time cold start (any channel < 60 s
to any channel)
Max. shuttered output power -30 dBm
(dark tuning)
1. STM-64 or OC-192 facility type has to be selected on the corresponding port
in the system management.
2. 10G FC with FEC not supported
The following table provides information about the network port for the
WCC-PCTN-10G-LN#DC.
This table provides information about the bit error rate versus OSNR for
WCC-PCTN-10G-LN#DC.
The following table provides information about the network port for the
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
WCC-PCTN-10G-V#DC.
This table provides information about the bit error rate versus OSNR for
WCC-PCTN-10G-V#DC.
The following table provides information about the network port for the
WCC-PCTN-10G-V#DL.
This table provides information about the bit error rate versus OSNR for
WCC-PCTN-10G-V#DL.
This table shows the recommended maximum pre-FEC bit error ratio for all
variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table contains information about the system performance for all variants.
Table 199: System Performance for all Variants
Max. module 3 µs with all supported protocols excepting OTU2 at the client
delay without port and with all supported protocols without FEC at the
client XFP network port;
10 µs with all supported protocols excepting OTU2 at the
client port and with OTU2 and GFEC at the network port;
55 µs with all supported protocols excepting OTU2 at the
client port and with OTU2 and EFEC-2 at the network port;
10 µs with OTU2 and with or without GFEC at the client port
and with OTU2 and without FEC at the network port;
20 µs with OTU2 and with or without GFEC at the client port
and with OTU2 and GFEC at the network port;
65 µs with OTU2 and with or without GFEC at the client port
and with OTU2 and EFEC-2 at the network port
Number of 15 using 2WCC-PCN-10G as bidirectional single module
regenerators N-N regenerator (OTU2, OTU1e and OTU2e with EFEC-2
only)
7 using 2WCC-PCN-10G as bidirectional single module C-N
regenerator (no FEC or GFEC on client ports only)
7 using WCC-PCTN-10G as back-to-back regenerator
(SDH/SONET/OTN only).
3 using 2WCA-PCN-10G (FEC bypass, C band, ALS
disabled) as bidirectional single module C-N regenerator
(SDH/SONET/10 GbE/10G FC and OTU2 with 10.709 Gbit/s
only).
This table shows information about fault monitoring of the module in general for
all variants.
This table shows information about fault monitoring of the client ports for all
variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 201: Fault Monitoring Client Interface - General for all Variants
Physical layer Laser failure; Laser degrade (based
on bias current); Receiver clock synch
failure; Loss of signal (LOS)
The following table gives information about fault monitoring of the client ports in
ingress direction for all variants.
Table 202: Fault Monitoring Client Interface - Ingress Direction for all
Variants
STM-64 RS/OC-192 section layer LOF; TIM
STM-64 MS/OC-192 line layer AIS; RDI; SD
OCH/OTU2 layer LOF; LOM; AIS
OTU2 layer - SM byte BDI; SD; TIM
ODU2 layer - PM byte AIS; BDI; OCI; LCK; SD; TIM
ODU2 layer - TCMi byte, i = 1...6 AIS; BDI; OCI; LCK; LTC; SD; TIM
Physical coding sublayer Loss of synchronization; Hi_BER;
(PCS 64B66B)1 Local fault; SD
1. valid for 10 GbE LAN PHY and 10G FC
This table shows information about fault monitoring of the network ports for all
variants.
Table 203: Fault Monitoring Network Interface - General for all Variants
Physical layer Laser failure; Receiver clock synch
failure; Loss of signal (LOS); Optical
power Rx too high/too low (OPR);
Optical power Tx too high/too low
(OPT)
This table provides information about fault monitoring of the network ports in
egress direction for all variants.
Table 204: Fault Monitoring Network Interface - Egress Direction for all
Variants
STM-64 RS/OC-192 section layer LOF; TIM
STM-64 MS/OC-192 line layer AIS; RDI; SD
OCH/OTU2 layer LOF; LOM; AIS
OTU2 layer - SM byte BDI; SD; TIM
ODU2 layer - PM byte AIS; BDI; OCI; LCK; SD; TIM
ODU2 layer -TCMi byte, i = 1 ... 6 AIS; BDI; OCI; LCK; LTC; SD; TIM
OPU2 layer AIS; PLM
Physical coding sublayer Loss of synchronization; Hi_BER;
(PCS 64B66B)1 Local fault; SD
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
1. valid for 10 GbE LAN PHY and 10G FC
This table shows information about performance monitoring of the client ports
for all variants.
Table 206: Performance Monitoring Client Interface - General for all Variants
Physical layer Transmitter bias current
(15 min/24 h records available for PM (current);
values except current values; Optical power Rx (current, low,
user configurable threshold crossing mean, high);
alerts for OPR too high/too low available; Optical power Tx (current, low,
fix threshold crossing alerts for OPT too mean, high)
high/too low available)
The following table gives information about performance monitoring of the client
ports in ingress direction for all variants.
Table 207: Performance Monitoring Client Interface - Ingress Direction for all
Variants
STM-64 RS/OC-192 section layer ES; SES; OOFS/SEFS;
(15 min/24 h records with user BBE/CV
configurable threshold crossing alerts
available)
STM-64 MS/OC-192 line layer ES; SES; UAS; BBE/CV
(15 min/24 h records with user
configurable threshold crossing alerts
available)
OCH/OTU2 layer ES; SES; UBE; CE
(15 min/ 24 h records with user
configurable threshold crossing alerts
available)
OTU2 layer - SM byte ES; SES; UAS; BBE
(15 min/ 24 h records with user
configurable threshold crossing alerts
available)
ODU2 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table gives information about performance monitoring of the client
ports in egress direction for all variants.
Table 208: Performance Monitoring Client Interface - Egress Direction for all
Variants
Framed 10 GbE services TX Good frames; TX Pause
frames; TX CRC frames;
Transmitted bytes
This table shows information about performance monitoring of the network ports
for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
configurable threshold crossing alerts
available)
ODU2 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
ODU2 layer - TCMi byte, i = 1 ... 6 ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
Physical coding sublayer (PCS 64B66B)1 ES; CV; SE
Framed 10 GbE services RX Good frames; RX Pause
frames; RX CRC frames;
Received bytes
1. valid for 10 GbE LAN PHY and 10G FC
The following table provides information about the loop functionality for all
variants.
This table provides information about protection switching for all variants.
This table provides information about the ECC for all variants.
4TCC-PCTN-2G7+10G
The 4TCC-PCTN-2G7+10G module is a 4-port time division multiplexing
channel modules with SFP type pluggable client interfaces. The client ports
support STM-16/OC-48 and OTU1. These services are multiplexed according to
OTN as described in ITU-T G.709 using transparent asynchronous aggregation
of ODU1 tributaries into OTU2. STM-16/OC-48 client interface signals at 2.488
Gbit/s are either transported transparently or regenerated at the RS/Section
layer. The client interface signals are end-to-end clock transparent and can be
used for clock distribution, but holdover is not supported. If demultiplexing fails,
a local 20 ppm oscillator will be used as clock source. The OTU1 client interface
signals at 2.666 Gbit/s are terminated at the OTU1 SM layer, and the ODU1 PM
is transparently multiplexed into OPU2. The network port supports OTU2 with
GFEC at 10.709 Gbit/s or OTU2V with EFEC-1 at 11.003 Gbit/s.
The module is available in three variants:
• 4TCC-PCTN-2G7+10G-LN#DC
• 4TCC-PCTN-2G7+10G-V#DC
• 4TCC-PCTN-2G7+10G-V#DL
The network ports of the 4TCC-PCTN-2G7+10G-LN#DC and
4TCC-PCTN-2G7+10G-V#DC are fully tunable in the C band in a wavelength
grid of 50 GHz.
The network port of the 4TCC-PCTN-2G7+10G-V#DL is fully tunable in the L
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
band in a wavelength grid of 100 GHz. The 4TCC-PCTN-2G7+10G-V#DC and
4TCC-PCTN-2G7+10G-V#DL have very long reach network interfaces whereas
the 4TCC-PCTN-2G7+10G -LN#DC features a long reach noise optimized
network interface. Due to the high extinction ratio the
4TCC-PCTN-2G7+10G-LN#DC is suitable for links with a large amount of
amplifiers and low OSNR.
Table 213 contains general information about all module variants and their
environment.
This table provides information about the client ports for all variants.
The following table provides a summary of the supported client SFPs. Please
refer to the specifications for the individual SFP type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table provides information about the network port for all variants.
The following table provides information about the network port for the
4TCC-PCTN-2G7+10G-LN#DC.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
OSNR penalty at -16 dBm Rx input 1 dB
power
For operation without FEC or with
FEC in Rel. 8.2
OSNR penalty at -18 dBm Rx input 1 dB
power
For operation with FEC starting
Rel. 8.3
OSNR penalty at 11.0032 Gbit/s 1 dB
This table provides information about the bit error rate versus OSNR for
4TCC-PCTN-2G7+10G-LN#DC.
1. To achieve the specified Pre-Fec Bit error ratio at OSNR values below 13 dB
the ATC may need up to 10 minutes for adjusting the threshold.
The following table provides information about the network port for the
4TCC-PCTN-2G7+10G-V#DC.
This table provides information about the bit error rate versus OSNR for
4TCC-PCTN-2G7+10G-V#DC.
Table 220: Bit Error Rate Versus OSNR for 4TCC-PCTN-2G7+10G-V#DC
Pre-FEC Bit Error Ratio < 10-12 at 25 dB OSNR at 0.1 nm
< 10-9 at 23 dB OSNR at 0.1 nm
< 10-5 at 19 dB OSNR at 0.1 nm
< 10-4 at 17 dB OSNR at 0.1 nm
< 10-3 at 16 dB OSNR at 0.1 nm
The following table provides information about the network port for the
4TCC-PCTN-2G7+10G-V#DL.
This table provides information about the bit error rate versus OSNR for
4TCC-PCTN-2G7+10G-V#DL.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 222: Bit Error Rate Versus OSNR for 4TCC-PCTN-2G7+10G-V#DL
Pre-FEC Bit Error Ratio < 10-12 at 25 dB OSNR at 0.1 nm
< 10-9 at 23 dB OSNR at 0.1 nm
< 10-5 at 19 dB OSNR at 0.1 nm
< 10-4 at 17 dB OSNR at 0.1 nm
< 10-3 at 16 dB OSNR at 0.1 nm
This table shows recommended maximum pre-FEC bit error ratio for all variants.
The following table provides information about the multiplexing scheme for all
variants.
The following table contains information about the system performance for all
variants.
regenerator.
Number of back-to-back cascades 7 using 4TCC-PCTN-2G7+10G
(without protection capability)
This table shows information about fault monitoring of the module in general for
all variants.
This table shows information about fault monitoring of the client ports for all
variants.
Table 227: Fault Monitoring Client Interface - General for all Variants
Physical layer Laser failure;
Laser degrade (based on bias
current);
Receiver clock synch failure;
Loss of signal (LOS)
The following table gives information about fault monitoring of the client ports in
ingress direction for all variants.
Table 228: Fault Monitoring Client Interface - Ingress Direction for all
Variants
STM-16 RS/OC-48 section layer LOF; TIM
STM-16 MS/OC-48 line layer AIS; RDI
OCH/OTU1 layer LOF; LOM; AIS
OTU1 layer - SM byte BDI; SD; TIM
ODU1 layer - PM byte AIS; BDI; OCI; LCK; SD; TIM
ODU1 layer - TCMi byte, i = 1...6 AIS; BDI; OCI; LCK; LTC; SD; TIM
This table shows information about fault monitoring of the client ports in egress
direction for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 229: Fault Monitoring Client Interface - Egress Direction for all
Variants
STM-16 RS/OC-48 section layer LOF
ODU1 layer - PM byte AIS; BDI; OCI; LCK; Loss of
frame/multiframe (LOFLOM); SD; TIM
OPU1 layer AIS; PLM
This table shows information about fault monitoring of the network ports for all
variants.
Table 230: Fault Monitoring Network Interface - General for all Variants
Physical layer Laser failure;
Receiver clock synch failure;
Loss of signal (LOS)
This table provides information about fault monitoring of the network ports in
egress direction for all variants.
Table 231: Fault Monitoring Network Ports - Egress Direction for all Variants
OCH/OTU2 layer LOF; LOM; AIS
OTU2 layer - SM byte BDI; SD; TIM
ODU2 layer - PM byte AIS; BDI; OCI; LCK; SD; TIM
ODU2 layer -TCMi byte, i = 1 ... 6 AIS; BDI; OCI; LCK; SD; TIM
OPU2 layer PLM; MSIM
This table shows information about performance monitoring of the client ports
for all variants.
Table 233: Performance Monitoring Client Interface - General for all Variants
Physical layer Transmitter bias current
(15 min/24 h records available for PM (current);
values except current values; Optical power Rx (current, low,
user configurable threshold crossing mean, high);
alerts for OPR too high/too low available; Optical power Tx (current, low,
fix threshold crossing alerts for OPT too mean, high)
high/too low available)
The following table gives information about performance monitoring of the client
ports in ingress direction for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 234: Performance Monitoring Client Interface - Ingress Direction for all
Variants
STM-16 RS/OC-48 section layer ES; SES; OOFS/SEFS;
(15 min/24 h records with user BBE/CV
configurable threshold crossing alerts
available)
STM-16 MS/OC-48 line layer ES; SES; UAS; BBE/CV
(15 min/24 h records with user
configurable threshold crossing alerts
available)
OTU1 layer - SM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
ODU1 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
Physical coding sublayer (PCS) SD; Loss of character
synchronization
ODU1 layer - TCMi byte, i = 1 ... 6 ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
The following table gives information about performance monitoring of the client
ports in egress direction for all variants.
Table 235: Performance Monitoring Client Interface - Egress Direction for all
Variants
ODU1 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
This table shows information about performance monitoring of the network ports
for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 237: Performance Monitoring Network Interface - Egress Direction for
all Variants
OCH/OTU2 layer CE; UBE; ES; SES
(15 min/24 h records with user
configurable threshold crossing alerts
available)
OTU2 layer - SM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
ODU2 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
ODU2 layer - TCMi byte, i = 1 ... 6 ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
This table shows information about the loop functionality for all variants.
This table provides information about protection switching for all variants.
The following table contains information about the ECC for all variants.
10TCC-PCTN-4GUS+10G
The 10TCC-PCTN-4GUS+10G channel modules are 10-port TDM channel
modules with pluggable client interfaces and one fixed 10 G long reach link,
tunable DWDM network interface. The network port is tunable in the C band or L
band, depending on the module variant.
The 10TCC-PCTN-4GUS+10G module is available in three variants:
• 10TCC-PCTN-4GUS+10G-LN#DC
• 10TCC-PCTN-4GUS+10G-V#DC
• 10TCC-PCTN-4GUS+10G-V#DL
The network port is configurable to either OTN or SDH/SONET. When running
OTN, three FEC operational modes are configurable:
• standard FEC,
• enhanced FEC and
• FEC bypass.
When the network interface is configured as OTN, the network transmission rate
is 10.709 Gbit/s.
In SDH/SONET mode, the network interface transmits at 9.953 Gbits/s.
The client interfaces support GbE, 1G FC, 2G FC, 4G FC, STM-1/OC-3,
STM-4/OC-12 and STM-16/OC-48 services.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The mixture of any of these services is possible as long as the total amount of
VC4s/STS-3c-SPEs is not exceeded.
The network ports of the 10TCC-PCTN-4GUS+10G-LN#DC and
10TCC-PCTN-4GUS+10G-V#DC are fully tunable in the C band to 50 GHz
wavelength spacing. In the L band, the network port of the
10TCC-PCTN-4GUS+10G-V#DL is fully tunable to 100 GHz wavelength
spacing.
The 10TCC-PCTN-4GUS+10G-V#DC and 10TCC-PCTN-4GUS+10G-V#DL
have very long reach network interfaces.
The 10TCC-PCTN-4GUS+10G-LN#DC features a long reach noise optimized
network interface. With a higher extinction ratio, it is suitable for links with a
higher number of amplifiers and a lower OSNR.
This module is not compatible with ITU-T G.813 and cannot be used
PS
Table 241 contains general information about all module variants and their
environment.
The following table provides information about the client ports for all variants.
This table provides a summary of the supported client SFPs. Please refer to the
specifications for the individual SFP type.
The following table provides information about the network port for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type LC
Fiber type SM 9 µm
Data rates 9.95328 Gbit/s, 10.7092 Gbit/s
Protocols STM-64, OC-192, OTU2
Tuning time (any channel to any < 45 s
ch.)
Tuning time cold start (any channel < 60 s
to any channel)
Max. shuttered output power -30 dBm
(dark tuning)
The following table provides information about the network port for the
10TCC-PCTN-4GUS+10G-LN#DC.
This table provides information about the bit error rate versus OSNR for
10TCC-PCTN-4GUS+10G-LN#DC.
Table 246: Bit Error Rate Versus OSNR for
10TCC-PCTN-4GUS+10G-LN#DC
Bit Error Ratio without FEC < 10-12 at 23 dB OSNR at 0.1 nm
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table provides information about the network port for the
10TCC-PCTN-4GUS+10G-V#DC.
This table provides information about the bit error rate versus OSNR for
10TCC-PCTN-4GUS+10G-V#DC.
Table 248: Bit Error Rate Versus OSNR for 10TCC-PCTN-4GUS+10G-V#DC
Pre-FEC Bit Error Ratio < 10-12 at 25 dB OSNR at 0.1 nm
< 10-9 at 23 dB OSNR at 0.1 nm
< 10-5 at 19 dB OSNR at 0.1 nm
< 10-4 at 17 dB OSNR at 0.1 nm
< 10-3 at 16 dB OSNR at 0.1 nm
The following table provides information about the network port for the
10TCC-PCTN-4GUS+10G-V#DL.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 249: Network Port - Optical Performance for
10TCC-PCTN-4GUS+10G-V#DL
Transmitter output power range +3 dBm ... +5 dBm
Transmitter wavelength range 41 channels, 100 GHz spacing in L
band acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 100 pm
Min. extinction ratio 10 dB
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -20 dBm ... -8 dBm
OSNR penalty at -22 dBm input 1 dB
power
OPR measurement range -22 dBm ... -5 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range +200 ps/nm ... +900 ps/nm
Dispersion load range with 1 dB -150 ps/nm ... +200 ps/nm and
OSNR penalty +900 ps/nm ... +1250 ps/nm
Dispersion load range with 2 dB -500 ps/nm ... -150 ps/nm and
OSNR penalty +1250 ps/nm ... +1600 ps/nm
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)
This table provides information about the bit error rate versus OSNR for
10TCC-PCTN-4GUS+10G-V#DL.
This table shows the recommended maximum pre-FEC bit error ratio for all
variants.
This table contains information about the multiplexing scheme for all variants.
Table below provides information about the operation modes for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table contains information about the system performance for all variants.
Table 254: System Performance for all Variants
Max. module delay for STM64: 47 µs
GbE OTU2: 48 µs without FEC, 54 µs with GFEC, 97 µs
with EFEC
Max. module delay for STM64: 53 µs
1G FC OTU2: 54 µs without FEC, 60 µs with GFEC, 105
µs with EFEC
Max. module delay for STM64: 36 µs
2G FC OTU2: 36 µs without FEC, 43 µs with GFEC, 86 µs
with EFEC
Max. module delay for STM64: 28 µs
4G FC OTU2: 28 µs without FEC, 35 µs with GFEC, 78 µs
with EFEC
Max. module delay for STM64: 124 µs
STM1/OC3 OTU2: 127 µs without FEC, 160 µs with GFEC,
210 µs with EFEC
Max. module delay for STM64: 72 µs
STM4/OC12 OTU2: 64 µs without FEC, 80 µs with GFEC, 110
µs with EFEC
Max. module delay for STM64: 40 µs
STM16/OC48 OTU2: 45 µs without FEC, 50 µs with GFEC, 90 µs
with EFEC
Max. differential VCAT 122.5 µs
delay
This table shows information about fault monitoring of the module in general for
all variants.
This table shows information about fault monitoring of the client ports in general
for all variants.
Table 256: Fault Monitoring Client Interface General for all Variants
Physical layer Laser failure;
Laser degrade (based on bias
current);
Loss of signal (LOS)
This table shows information about fault monitoring of the client ports in ingress
direction for all variants.
Table 257: Fault Monitoring Client Interface - Ingress Direction for all
Variants
Physical coding sublayer (PCS) Loss of character synchronization
(not supported for STM-1/OC-3,
STM-4/OC-12, STM-16/OC-48
services)
This table shows information about fault monitoring of the network ports for all
variants.
Table 258: Fault Monitoring Network Interface - General for all Variants
Physical layer Laser failure;
Receiver clock synch failure;
Loss of signal (LOS)
This table provides information about fault monitoring of the network ports for all
variants.
Table 259: Fault Monitoring Network Interface - Egress Direction for all
Variants
STM-64 RS/OC-192 section layer LOF
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
STM-64 MS/OC-192 line layer AIS, RDI, SD
VC-4/STS3c-SPE layer AIS, LOP, RDI, PLM, UNEQ
OCH/OTU2 layer LOF, LOM, AIS
OTU2 layer - SM byte BDI, SD, TIM
ODU2 layer - PM byte AIS, BDI, OCI, LCK, SD, TIM
ODU2 layer -TCMi byte, i = 1...6 AIS, BDI, OCI, LCK, LTC, SD, TIM
OPU2 layer AIS, PLM
GFP common LOF, PLM, SSF
GFP-T Loss of client signal far end (10B_ERR,
CMF UPI)
Loss of character synchronization far
end (CMF UPI)
This table shows information about performance monitoring of the client ports for
all variants.
Table 261: Performance Monitoring Client Interface - General for all Variants
Physical layer Transmitter bias current
(15 min/24 h records available for PM values (current); Optical power
except current values; user configurable Rx (current, low, mean,
threshold crossing alerts for OPR too high/too high); Optical power Tx
low available; fix threshold crossing alerts for (current, low, mean,
OPT too high/too low available) high)1
1. Transmitter bias current, optical power Rx and optical power Tx are not
supported for electrical SFPs.
The following table gives information about performance monitoring of the client
ports in ingress direction for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 262: Performance Monitoring Client Interface - Ingress Direction for all
Variants
Ethernet PM Rx Received frames, Pause frames,
Bad frames (CRC), Received
bytes
Ethernet PM Tx Transmitted frames, Pause
frames, Bad frames (CRC),
Transmitted bytes
Physical coding sublayer (PCS) ES; CV; DE1 (not supported for
STM-1/OC-3, STM-4/OC-12,
STM-16/OC-48 services)
1. DE counter is not supported for electrical SFPs.
This table shows information about performance monitoring of the network ports
for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
(15 min/24 h records available) Discarded GFP frames due to
cHEC errors;
Discarded GFP frames due to
tHEC errors
GFP-T (15 min/24 h records available) Discarded superblocks due to
CRC errors
This table provides information about the loop functionality for all variants.
This table shows information about protection setting for all variants.
This table contains information about the ECC for all variants.
10TCC-PCN-2G7US+10G
The 10TCC-PCN-2G7US+10G is a 10-port 10G Add Drop Multiplexer (ADM)
module that can be configured to provide a single ADM function within an ADM
network of modules. The ADM function provides up to 10 interfaces for client
signals to be added and dropped or passed through and transported over the
ADM network (which is a subnetwork of the core optical network). The client
interfaces are customer-facing and the network interfaces are network-facing.
Since the client interfaces are lower rate services (lower than 10 Gbit/s), the
module cannot be used as a regenerator.
This module can transport up to ten GbE services (including synchronous GbE),
STM1/OC3, STM4/OC12, or up to eight STM-16/OC-48 and OTU1 services with
two network interfaces configured. Any Client service can be routed to either of
the Network interfaces. An OTU1 client service can be terminated at the OPU
layer, and up to two ODU0s can be de-multiplexed and routed individually. One
or both of the ODU0s de-multiplexed from a client OTU1 service can be routed
to another Client interface and the mapped GbE service can be add/dropped
(Local C-to-C service).
The module supports path protection and Client Channel Card Protection
(CCCP). Performance monitoring and fault management of physical layer
alarms and service-related alarms are also supported.
Table 268 provides general information about the module and the environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 268: Module - General Information
Equipment type 10TCC10G
First release 11.1
MTBF at 25°C ambient 194,214 h
temperature
Typ. power consumption 80 W
(incl. SFPs)
Max. power consumption 100 W
(incl. SFPs)
Width 8 HP
Height 5 HU
Weight (incl. SFPs) 1.3 kg
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according IP20. Use in a pollution degree 2
to IEC 60529 environment and indoor controlled office
environments only.
Slot positions SH9HU: 3...17
SH7HU, SH7HU-R: 3...171
SH1HU-HP/2DC, SH1HU-R/PF and
SH1HU-HP/E-TEMP/2DC: 1
NCU types NCU-II, NCU-II-P
G.8265
STM-n according to G.783 and G.813
Table 271 provides a summary of the supported client SFPs. Please refer to the
specifications for the individual SFP type.
Table 273 provides a summary of the supported network XFPs. Please refer to
the specifications for the individual XFP type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 274 provides information about the recommended maximum pre-FEC bit
error ratio.
PS
following tables are applicable for a specific deployment depends
on the configuration of the respective interface.
Note
Table 277 provides information about fault monitoring of the module in general.
Table 278 provides information about fault monitoring of the client ports for the
physical layer.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 279 provides information about fault monitoring of the client ports in
ingress direction.
Table 280: Fault Monitoring Client ODU [VCH] with mapped Client signal
(STM1/OC3, STM4/OC12, STM16/OC48, GbE)
ODU layer - PM byte AIS, OCI, LCK, BDI, TIM
OPU layer CSF, AIS, PLM
GFP LOF, PLM, LOSFWD, CHARSYNC-FEND
Table 282 provides information about fault monitoring of the network ports for
the physical layer.
Table 283 provides information about fault monitoring of the network ports for
the data layer in egress direction.
Table 284 provides information about fault monitoring of the network ports for the
data layer from Network OTU2.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Equipment Module temperature (current value)
(Fix threshold crossing alert for module
temperature too high available)
Table 286 provides information about performance monitoring of the client ports
for the physical layer.
Table 287 provides information about performance monitoring of the client ports
in ingress direction.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
threshold available)
TCM layer PMs ES; SES; BBE; UAS
(15 min/24 h records with user configurable
threshold available)
10WXC-PCN-10G
The 10WXC-PCN-10G is an ODU switching module providing 10x 10G ports for
a combined switching capability of 100Gbps.
Each 10 x 10G port supports service types of OTU2, OTU2e, STM-64/OC-192,
10GBE WAN, and 10GBE LAN. The STM-64/OC-192, 10GBE WAN, and
10GBE LAN service types are mapped into ODU2 or ODU2e for switching.
OTU2e services may be switched as an ODU2e and/or demapped back to
10GBE LAN.
OTU2 services are either switched as ODU2 and/or demapped back to
STM-64/OC-192, 10GBE WAN or demultiplexed to component ODU1s or
ODU0s which are space and time switched to another port where the
component ODU1s and ODU0s are multiplexed back into an OTU2.
All 10G ports accept a range of XFP MSA compliant pluggable transceivers.
The 10WXC-PCN-10G is capable of operating as a stand-alone module
interfacing to other FSP 3000R7 10G modules or to third party equipment.
Table 295 contains general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Height 5 HU
Weight approx. 1.5 kg (3.500 lbs)
Environmental conditions1 Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 140,887 h
Typ. power consumption 165 W
Max. power consumption 185 W
Max power consumption in 175 W
stand-alone applications
Slot positions SH9HU: 3...17
NCU types NCU-II, NCU-II-P
1. If the module is operated in the 9HU shelf, the fan speed will automatically be
increased to generate greater airflow.
Table 300 the recommended maximum pre-FEC bit error ratio for the traffic
ports.
Table 301 provides information about the mapping and multiplexing schemes.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 301: Multiplexing and Mapping Schemes
OTN multiplexing
Mapping OTU2/ODU2
Mapping OTU2e/ODU2e
Multiplexing OTU2/ODU2/OPU2/ODTUG2/(4x)ODTU12/ODU1 (4x ODU1)
Multiplexing OTU2/ODU2/OPU2/ODTUG2/(8x)ODTU2.1/ODU0 (8x ODU0)
Non-blocking cross-connect of ODU2 between any ports
Non-blocking cross-connect of ODU2e between any ports
Non-blocking cross-connect of ODU1 between any ports
Non-blocking cross-connect of ODU0 between any ports
Multiplexing into ODU2: any combination of supported ODUs on the same
ODU2
Multiplexing into ODU2: supported ODUs multiplexed into any tributary slot
OTN mapping
Bit synchronous mapping of 10G LAN into OPU2e
Bit synchronous mapping of 10G WAN into OPU2
Bit synchronous mapping of STM-64 into OPU2
Bit synchronous mapping of OC-192 into OPU2
PS
following tables are applicable for a specific deployment depends
on the configuration of the respective interface.
Note
Table 303 provides information about fault monitoring on the module equipment
level in general.OK
Table 304 provides information about fault monitoring of the traffic interfaces in
general. OK
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Physical layer Laser failure
Laser degrade (based on bias current)
Receiver clock synch failure (RCVCLK)
Loss of signal (LOS)
ODU2 layer - PM byte (15 min/ 24 h records ES; SES; UAS; BBE
with user configurable threshold)
ODU2 layer - PM byte (15 min/ 24 h records ES; SES; UAS; BBE
with user configurable threshold)
ODU1 layer - PM byte (15 min/ 24 h records ES; SES; UAS; BBE
with user configurable threshold)
ODU0 layer - PM byte (15 min/ 24 h records ES; SES; UAS; BBE
with user configurable threshold)
10GBE LAN - Physical Coding Sublayer ES, CV, SE
10GBE LAN Ethernet Rx Framed Statistics Good Frames; Pause
(15 min/24h records) Frames; CRC Frames;
Bytes
10GBE LAN Ethernet Tx Framed Statistics Good Frames, Pause
(15 min/24 h records) Frames, CRC Frames,
Bytes
10GBE WAN section layer (15 min/24 h ES, SES, SEFS/OOFS,
recored with user configurable threshold CV/BBE
crossing)
10GBE WAN line layer (15 min/24 h recored ES, SES, UAS, CV/BBE
with user configurable threshold crossing)
STM-64/OC192 section layer (15 min/24 h ES, SES, SEFS/OOFS,
recored with user configurable threshold CV/BBE
crossing)
STM-64/OC192 line layer (15 min/24 h recored ES, SES, UAS, CV/BBE
with user configurable threshold crossing)
Table 308 provides information about provides information about the ECC.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
2WCC-PCN-10G
The 2WCC-PCN-10G channel module is a 10G dual core channel module with
two XFP type pluggable client interfaces and two XFP type pluggable network
interfaces.
The 2WCC-PCN-10G is intended for transport of STM-64, OC-192, 8G FC,
10 GbE, OTU2, OTU1e, and OTU2e services.
All applications can be transmitted natively. STM-64, OC-192, 8G FC, and 10
GbE services can be mapped into an OTU2 signal. 10 GbE services can also be
mapped into an OTU1e signal or an OTU2e signal. OTU2, OTU1e, and OTU2e
services cannot be mapped. GFEC can be enabled for OTU2, OTU1e and
OTU2e services at both the client port and the network port. EFEC with higher
coding gain is only supported on the network port.
The module provides performance monitoring data at the client port as well as at
the network port for the physical layer and the SDH/SONET or the OTN layer.
Other levels of PMs like PCS and Packet are also supported.
All optical interfaces utilize XFP pluggable optics. Therefore, if only a single
transponder function is desired, then only one Client interface and one Network
interface needs to be populated with XFPs. The XFP pluggable optics provides
the optical-to-electrical conversion (and vice versa) and collection of all PHY
(Physical) Layer PMs for each interface. It also provides the Loss Of Signal
(LOS) alarm monitoring.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table contains general information about the module and their
environment.
The following table provides a summary of the supported client port XFPs.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
850 nm types XFP/10G/850I/MM/LC (HW Rev. 1.01 or newer)
XFP/8G/850I/MM/LC
1310 nm types XFP/11G/1310S/SM/LC (HW Rev. 3.01 or newer)
XFP/8G/1310S/SM/LC
1550 nm types XFP/11G/1550L/SM/LC (HW Rev. 2.00 or newer)
CWDM types XFP/11G/CxxxxL/SM/LC (HW Rev. 2.00 or newer)
XFP/11G/CxxxxV/SM/LC (HW Rev. 2.00 or newer)
XFP/8G/CxxxxL/SM/LC
DWDM types XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev. 4.01, 5.01 or
newer)
XFP/11G/#19xxxL50/SM/LC
XFP/11G/DCTV/SM/LC (HW Rev. 1.01 or newer)
XFP/11G/DCTLNR/SM/LC (HW Rev 1.01 or newer)
XFP/11G/DCTLN/SM/LC (HW Rev 1.01 or newer)
XFP/8G/#xxxxxL/SM/LC#Dxx (HW Rev. 2.00 or newer)1
1. The maximum ambient temperature is restricted to 50°C.
The following table provides a summary of the supported network port XFPs.
XFP/11G/#19xxxL50/SM/LC
XFP/11G/DCTV/SM/LC (HW Rev. 1.01 or newer)
XFP/11G/DCTLNR/SM/LC (HW Rev 1.01 or newer)
XFP/11G/DCTLN/SM/LC (HW Rev 1.01 or newer)
XFP/8G/#xxxxxL/SM/LC#Dxx (HW Rev. 2.00 or newer)
This table shows the recommended maximum pre-FEC bit error ratio.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
3 μs with 8G FC at the client ports and network ports
25 μs with 8G FC at the client ports and OTU without FEC at
the network ports.
32 μs with 8G FC at the client ports and OTU2 with GFEC at
the network ports.
75 μs with 8G FC at the client ports and OTU2 with EFEC at
the network ports.
Number of 15 using 2WCC-PCN-10G as bidirectional single module
regenerators N-N regenerator (OTU2, OTU1e and OTU2e only; no FEC,
allowed in GFEC or EFEC)
data path 15 using 2WCC-PCN-10G as dual bidirectional single
module C-N regenerator (no FEC or GFEC on client ports
only)
7 using WCC-PCTN-10G as back-to-back regenerator
(SDH/SONET/OTN only).
3 using 2WCA-PCN-10G (FEC bypass, C band, ALS
disabled) as bidirectional single module C-N regenerator
(SDH/SONET/10 GbE and OTU2 with 10.709 Gbit/s only).
Max. frame no limitation in transmission (for performance monitoring
size limited to 16387 bytes)
This table shows information about fault monitoring of the module in general.
This table shows information about fault monitoring of the client ports.
This table shows information about fault monitoring of the module network ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
available;
fix threshold crossing alerts for OPT
too high/too low available)
The following table gives information about performance monitoring of the client
ports in the ingress direction.
The following table gives information about performance monitoring of the client
ports in the egress direction.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Client port switching criteria Client XFP removed, (Switching
criteria applies to Client Channel Card
Protection only, but not to Channel
Protection.)
Network signal fail switching LOS, Receiver clock synch failure
criteria physical
Network signal fail switching LOF-S, AIS-L
criteria
STM-64/OC-192
Network signal fail switching OTU-LOF, OTU-AIS, OTU-LOM,
criteria OTN ODU-AIS, ODU-LCK, ODU-OCI
Network signal degrade switching SD-L (MS-DEG/SD based on B2) with
criteria provisionable threshold.
STM-64/OC-192 Support of enabling/disabling SD-L
based on B2 as protection.
Network signal degrade switching SNC/N ODU-SD (based on PM[2])
criteria OTN with provisionable threshold.
Support of enabling/disabling SD
based on PM[2] as protection.
Network physical coding switching Loss of Synch, HI_BER, Local Fault
criteria
Restoration scheme Versatile switched protection,
The module must not be configured to
Client channel card protection.
(RSM-OLM, VSM)
Restoration time <1s
2TWCC-PCN-2G7U
The 2TWCC-PCN-2G7U is a 2.7 Gbit/s core type WDM channel module with
two pluggable client and two pluggable network interfaces. The module can
operate as a single or a dual transponder or as a multiplexer. When operating
as a single transponder, it is possible to transport one unprotected or channel
protected OTU1, one STM-16/OC-48/OTU1 or one STM-16/OC-48 wrapped
into an OTU1. When operating as a dual transponder, it is possible to transport
two unprotected STM-16/OC-48/OTU1, or two STM-16/OC-48 wrapped into
OTU1, or two OTU1 services.
The Transponder Modes (both dual transponder and protected transponder)
support the following applications:
• OTU1 to OTU1
• STM-16/OC-48 to STM-16/OC-48
• STM-16/OC-48 to OTU1
When operating as a 2 port Multiplexer, two mapping/multiplexing methods are
available, an SDH/SONET method and an OTN method.
When operating as a SDH/SONET multiplexer, unprotected or channel
protected transport of 2x GbE or 2x G FC or 1GbE and 1G FC or 1x 2G FC
services are possible. The client signals are multiplexed into one
STM-16/OC-48 using GFP-T and continuous concatenation. The STM-16/OC48
signal may be transported in its native form or as an OTU1 (the STM-16/OC48
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
signal is wrapped into the OTU1). The 2G FC service is only allowed to be
applied at client port 1.
The OTN method maps GbE into an ODU0 which are multiplexed into an OTU1.
When rate limiting is not used, GBE is mapped into the ODU0 using TTT/GMP.
When rate limiting is used, GBE is mapped into ODU0 using GFP-F. The
resulting ODU0s are multiplexed into an OPU1/ODU1/OTU1 for transport.
The module supports Channel protection and Client Channel Card protection
(CCCP). CCCP is available for all modes and conditions with the exception of
an OTN Muxponder when rate limiting is used.
Performance monitoring and fault management of physical layer alarms on
client and network ports are also supported.
Table 326 provides general information about the module and its environment.
Table 328 provides a summary of the supported client SFPs. Please refer to the
specifications for the individual SFP type.
Table 330 provides a summary of the supported network SFPs. Please refer to
the specifications of the individual SFP type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
mapping/multiplexing With rate limit:
method GBE->GFP-F->ODU0->OPU1/ODU1/OTU1.
Transponder mode Transmission without protocol modification and
change of data rate (OC-48/STM-16/OTU1 only)
Wrapping Synchronous mapping of STM-16/OC48 into ODU1
and transport of OTU1 acc. to ITU-T G.709
Table 333 provides information about fault monitoring of the module in general.
Table 334 provides information about fault monitoring of the client ports.
Table 335 provides information about fault monitoring of the client ports in
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ingress direction.
Table 336 provides information about fault monitoring of the network ports.
Table 337 provides information about fault monitoring of the network ports in
egress direction.
general.
Table 340 provides information about performance monitoring of the client ports
in ingress direction.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ODU1 layer - TCMi byte i = 1...6 ES; SES; UAS; BBE
Physical coding sublayer ES; CV; DE
Ethernet layer GbE service Good frames;
Pause frames;
Discarded frames;
Bad frames (CRC);
Received bytes
Table 341 provides information about performance monitoring of the client ports
in egress direction.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Support of enabling/ disabling SD
based on SM[2] as protection criteria
Signal fail switching criteria AIS-P, LOP-P, UNEQ-P, PLM-P
STM/SONET muxponder path:
Signal Fail switching criteria OTN MSIM, LOFLOM, AIS, LCK, OCI,
muxponder, ODU0 layer:
Signal Fail switching criteria OTN CSF, AIS, PLM
muxponder, OPU0 layer
Signal Fail switching criteria LOF, PLM, client loss of signal, client
loss of character sync.
muxponder, GFP layer:
Restoration scheme Versatile switched protection,
The module must not be configured for
channel protection.
(RSM-SF, RSM-OLM, VSM)
Restoration time <1s
WCC-PC1N-2G7U
The WCC-PC1N-2G7U is a channel module with one SFP type pluggable client
and one SFP type pluggable network interface for data rates up to 2.7 Gbit/s. It
supports STM-1, STM-4, STM-16, OC-3, OC-12, OC-48, OTU1 and GbE
services. STM-16/OC-48 can be mapped according to G.709 resulting in an
OTU1 service. GFEC can be enabled for OTU1 services at both the client port
and the network port.
Table 347 contains general information about the module and its environment.
This table provides a summary of the supported client SFPs. Please refer to the
specifications for the individual SFP type.
This table provides a summary of the supported network SFPs. Please refer to
the specifications for the individual SFP type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFP/2G5U/CxxxxV/SM/LC
DWDM types SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx
This table shows information about fault monitoring of the module in general.
This table shows information about fault monitoring of the client ports.
The following table gives information about fault monitoring of the client ports in
ingress direction.
This table shows information about fault monitoring of the network ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table gives information about fault monitoring of the network ports
in egress direction.
These tables show information about performance monitoring of the client ports.
This table shows information about performance monitoring of the network ports
in egress direction.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
OCH/OTU1 layer CE; UBE; ES; SES
(15 min/24 h records with user
configurable threshold crossing alerts
available)
OTU1 layer - SM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
ODU1 layer - PM byte ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
ODU1 layer -TCMi byte, i = 1 ... 6 ES; SES; UAS; BBE
(15 min/24 h records with user
configurable threshold crossing alerts
available)
Physical coding sublayer (PCS) ES; Coding Violation +
Disparity Error (CVDE)
“2WCA-PCN-10G” on p. 251
“4TCA-PCN-4GU+4G” on p. 256
“4TCA-PCN-4GUS+4G” on p. 262
“WCA-PCN-2G5U” on p. 268
2PCA-PCN-10G
The 2PCA-PCN-10G is a 4-port packet channel access module with two
10 GbE client XFP and two 10 GbE network XFP type pluggable interfaces. It
supports transport, aggregation and cross-connect of up to 400 Ethernet Virtual
Connections (EVCs) in accordance with IEEE 802.1ad Provider Bridges and
MEF10.1 specifications of Ethernet services.
This module is intended to be deployed in an SH9HU, SH7HU, SH1HU-HP/2DC
or SH1HU-R/PF with the following requirements:
• use of the NCU-II or NCU-II-P modules in the network element (NE) of an
SH9HU Shelf
• use of the NCU-II module in the network element (NE) of an SH7HU,
SH1HU-HP/2DC, SH1HU-HP/E-TEMP/2DC or SH1HU-R/PF Shelf
• deployment of a maximum of six Ethernet L2 aggregation modules (six
2PCA-PCN-10G modules or in total a mix of six 2PCA-PCN-10G and
10PCA-PCN-1G3+10G modules) per network element
• support of a maximum of 1600 EVCs per network element
This module can also be deployed in an SH7HU, with the following
requirements and resulting condition:
• deployment of a maximum of three 2PCA-PCN-10G modules in specific slot
positions in the shelf (due to heat dissipation)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• adjacent slots may be equipped with modules with a maximum power
requirement of 10 W
• the network element uses the NCU-II controller
• the network element will be ETSI compliant (maximum ambient temperature
of +45°C or +113°F)
Table 367 contains general information about the module and its environment.
XFP/11G/CxxxxV/SM/LC
DWDM types XFP/11G/Dxxxx.xxV/SM/LC#Dxx
XFP/OTN11G/#19xxxV/SM/LC
XFP/11G/DCTV/SM/LC
The following table provides a summary of the supported network XFPs. Please
refer to the specifications for the individual XFP type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
L2CP (layer 2 control protocol) filter Fixed filters in acc. with MEF6.1
(peer/tunnel/discard)
Policing properties CIR, CBS. User-configurable, individual
per EVC
Shaping properties CIR, CBS. User-configurable, individual
per EVC
MAC learning No
Buffer size 1 Mbit per EVC
This table shows information about fault monitoring of the module in general.
This table shows information about performance monitoring of the client ports.
This table shows details about performance monitoring of the network ports.
This table shows information about performance monitoring of the network ports
and client ports on Rx.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
1024 - 1518 bytes frames
1519 - max frame size frames
Undersized frames (<64 bytes)
Oversized frames (> max frame size)
FCS error frames
Inter-packet junk
Per EVC Rx Unicast frames (prior to policing)
Multicast frames (prior to policing)
Frames marked green (by policer)
Bytes marked green (by policer)
Frames marked red and dropped (by policer)
Bytes marked red and dropped (by policer)
Frames dropped due to buffer overflow
Bytes dropped due to buffer overflow
1. There is a small time difference between the capture of the Bytes and
Frames counters. This is observable when testing with fixed length frames.
The Bytes counter will then not be equal to the Frames counter “frame
length”. The size of the deviation is only linked to the packet rate at the time
the counters are captured.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 384: Protection Switching - Link Aggregation Protection
Protection scheme Link Aggregation, active-standby
(IEEE 802.1ax)
Protection characteristics • "1:1"-like protection, bi-directional
switching
• revertive and non-revertive
Protection switching time < 6 sec
Protection group supported on all ports, all port modes, all port roles
Operations Switching possible by manipulating port
priority
Switching criteria LOS, LACP timeout
10PCA-PCN-1G3+10G
The 10PCA-PCN-1G3+10G is a 12-port packet channel access module with ten
1 GbE client SFP and two 10 GbE network XFP type pluggable interfaces. It
supports transport, aggregation and cross-connect of up to 400 Ethernet Virtual
Connections (EVCs) in accordance with IEEE 802.1ad Provider Bridges and
MEF10.1 specifications of Ethernet services.
This module is intended to be deployed in an SH9HU, SH7HU, SH1HU-HP/2DC
or SH1HU-R/PF with the following requirements:
• use of the NCU-II or NCU-II-P modules in the network element (NE) of an
SH9HU Shelf
• use of the NCU-II module in the network element (NE) of an SH7HU,
SH1HU-HP/2DC, SH1HU-HP/E-TEMP/2DC or SH1HU-R/PF Shelf
• deployment of a maximum of six Ethernet L2 aggregation modules (six
10PCA-PCN-1G3+10G modules or in total a mix of six 2PCA-PCN-10G and
10PCA-PCN-1G3+10G modules) per network element
• support of a maximum of 1600 EVCs per network element
This module can also be deployed in an SH7HU, with the following
requirements and resulting condition:
• deployment of a maximum of three 10PCA-PCN-1G3+10G modules in
specific slot positions in the shelf (due to heat dissipation)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table provides a summary of the supported client SFPs. Please
refer to the specifications for the individual SFP type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFP/2G5U/1310L/SM/LC
CWDM SFP/2G5U/CxxxxL/SM/LC
SFP/2G5U/CxxxxV/SM/LC
DWDM types SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx
The following table provides a summary of the supported network XFPs. Please
refer to the specifications for the individual XFP type.
L2CP (layer 2 control protocol) filter Fixed filters in acc. with MEF6.1
(peer/tunnel/discard)
Policing properties CIR, CBS. User-configurable, individual
per EVC
Shaping properties CIR, CBS. User-configurable, individual
per EVC
MAC learning No
Buffer size 1 Mbit per EVC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
231 µs (95% load) 231 µs (95% load)
Number of regenerators 3 using WCC-PCTN-10G as back-to-back
regenerator (C band only, ALS disabled)
3 using 2WCC-PCN-10G as bidirectional
single module C-N regenerator
3 using 2WCA-PCN-10G as bidirectional
single module C-N regenerator
1. The 40 and 400 flows columns are the number of flows scheduled on the
network port in each case. The load numbers are the traffic load on the
network port.
2. The module delay numbers are the sum of module delay from client port to
network port and from network port back to client port.
This table shows information about fault monitoring of the module in general.
This table shows information about fault monitoring of the network ports.
This table shows information about performance monitoring of the client ports in
general.
This table shows information about performance monitoring of the network and
client ports on Rx.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
512 - 1023 bytes frames
1024 - 1518 bytes frames
1519 - max frame size frames
Undersized frames (<64 bytes)
Oversized frames (> max frame size)
FCS error frames
Inter-packet junk (Network Interface only)
Per EVC Rx Unicast frames (prior to policing)
Multicast frames (prior to policing)
Frames marked green (by policer)
Bytes marked green (by policer)
Frames marked red and dropped (by policer)
Bytes marked red and dropped (by policer)
Frames dropped due to buffer overflow
Bytes dropped due to buffer overflow
1. There is a small time difference between the capture of the Bytes and
Frames counters. This is observable when testing with fixed length frames.
The Bytes counter will then not be equal to the Frames counter “frame
length”. The size of the deviation is only linked to the packet rate at the time
the counters are captured.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 404: Protection Switching - Link Aggregation Protection
Protection scheme Link Aggregation, active-standby
(IEEE 802.1ax)
Protection characteristics • "1:1"-like protection, bi-directional
switching
• revertive and non-revertive
Protection switching time < 6 sec
Protection group supported on all ports, all port modes, all port roles
Operations Switching possible by manipulating port
priority
Switching criteria LOS, LACP timeout
2WCA-PCN-10G
The 2WCA-PCN-10G is a 10G channel module with two XFP type pluggable
client and two XFP type pluggable network interfaces. The module supports 4G
FC, 8G FC, STM-64/OC-192, 10G FC, 10 GbE WAN PHY, 10 GbE LAN PHY
and OTU2.
The 2WCA-PCN-10G is intended to be used as:
• Unprotected single transponder or regenerator (C1 to NE or C2 to NW)
• Unprotected dual transponder or regenerator (C1 to NE and C2 to NW)
• Channel protected single transponder (C1 to NW/NE)
It provides performance monitoring at the client as well as at the network ports
for the physical layer.
Table 405 contains general information about the module and its environment.
The following table provides a summary of the supported client XFPs. Please
refer to the specifications of the individual XFP type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Number of network ports 2
Type of network ports XFP
Data rates 4.25 Gbit/s, 8.5 Gbit/s, 9.9532 Gbit/s,
10.3125 Gbit/s, 10.51875 Gbit/s, 10.709 Gbit/s
The following table provides a summary of the supported network XFPs. Please
refer to the specifications of the individual XFP type.
Table 409: Supported Network XFPs
850 nm types XFP/10G/850I/MM/LC
1310 nm types XFP/11G/1310S/SM/LC
(HW Rev. 2.03 or newer)
1550 nm types XFP/11G/1550L/SM/LC
CWDM types XFP/8G/CxxxxL/SM/LC
XFP/11G/CxxxxL/SM/LC
XFP/11G/CxxxxV/SM/LC
DWDM types XFP/8G/#xxxxxL/SM/LC#Dxx
XFP/11G/Dxxxx.xxV/SM/LC#Dxx1
XFP/11G/DCTV/SM/LC
XFP/11G/#19xxxL50/SM/LC
XFP/16GFC/#19xxxL50/SM/LC
This table shows information about fault monitoring of the module in general.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table shows information about fault monitoring of the client ports in general.
This table shows information about fault monitoring of the network ports in
general.
This table shows information about performance monitoring of the client ports in
general.
This table gives information about performance monitoring of the client ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table shows information about performance monitoring of the network ports
in general.
4TCA-PCN-4GU+4G
The 4TCA-PCN-4GU+4G is an access type 4-port time division multiplexing
channel module with four client and two network SFP type pluggable interfaces.
All client and network interfaces are SFP types. It supports the transport of GbE,
1G, 2G or 4G FC signals. These applications are multiplexed to a data rate of
4.25 Gbit/s with a proprietary protocol for transmission at the network interfaces.
The network interfaces provide channel protection as well.
The 4TCA-PCN-4GU+4G features dynamic add/drop traffic per client interface
to multiplex and demultiplex the transmitted signal.
Table 421 contains general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 355,216 h
Typ. power consumption (incl. SFPs) 16 W in converter mode (TRANSW)
22 W in all other modes
Max. power consumption (incl. SFPs) 18 W in converter mode (TRANSW)
25.0 W in all other modes
Maximum RAM consumption on NCU 1,376 Kbytes
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P
The following table provides a summary of the supported client SFPs. Please
refer to the specifications of the individual SFP type.
The following table provides a summary of the supported network SFPs. Please
refer to the specifications of the individual SFP type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
No fixed mapping. Every service has
to be cross-connected.
It is possible to mix 1 GbE and 1G FC
services. Services of 1 GbE, 1G FC
and 2G FC can be combined up to a
4G network stream to NE and
another 4G network stream to NW.
Pass-through network to network is
not possible for 4G FC as transported
service.
Drop and Continue capability with 1 GbE towards C1, C2, C3, C4
two network ports equipped of the
following services:
Bi-directional C1-NW regenerator 4G FC on C1
(Transponder West (TRANSW)),
only C band is supported for client
and network port
This table shows information about fault monitoring of the module in general.
This table shows information about fault monitoring of the client ports in general.
This table shows information about fault monitoring of the network ports in
general.
This table shows information about fault monitoring of the network ports in
egress direction.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Server Signal Failure of sub-aggregate service
This table shows information about performance monitoring of the client ports.
The following table gives information about performance monitoring of the client
ports in ingress direction.
4TCA-PCN-4GUS+4G
The 4TCA-PCN-4GUS+4G is an access type 4-port time division multiplexing
channel module with four client and two network SFP type pluggable interfaces.
All client and network interfaces are SFP types. It supports the transport of
STM-1/OC-3, STM-4/OC-12 and GbE signal types. These applications are
multiplexed to a data rate of 4.25 Gbit/s with a proprietary protocol for
transmission at the network interfaces. The network interfaces provide channel
protection as well. The 4TCA-PCN-4GUS+4G features dynamic add/drop traffic
per client interface to multiplex and demultiplex the transmitted signal.
This module is not compatible with ITU-T G.813 and cannot be used
PS
Table 440 contains general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Weight (incl. SFPs) 640 g (1.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 486,509 h
Typ. power consumption (incl. SFPs) 22 W
Max. power consumption (incl. SFPs) 25 W
Maximum RAM consumption on NCU 3,074 Kbytes
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P
The following table provides a summary of the supported client SFPs. Please
refer to the specifications of the individual SFP type.
Protocols proprietary
Type of network ports SFP
The following table provides a summary of the supported network SFPs. Please
refer to the specifications of the individual SFP type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• 6 x STM-1/OC-3 and 3 x 1GbE
• STM-4/OC-12
• 4 x 1GbE
• STM-4/OC-12
This table shows information about fault monitoring of the module in general.
This table shows information about fault monitoring of the client ports in general.
This table shows information about fault monitoring of the network ports in
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
general.
This table shows information about fault monitoring of the network ports in
egress direction.
This table shows information about performance monitoring of the client ports.
The following table gives information about performance monitoring of the client
ports in ingress direction.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
user configurable threshold crossing alerts mean, high);
for OPR too high/too low available) Transmitter bias current (current)
WCA-PCN-2G5U
The WCA-PCN-2G5U is a channel module with one pluggable client and two
pluggable network interfaces of SFP type. This module supports data rates of
100 Mbit/s up to 2.67 Gbit/s at the client interfaces. All services are transmitted
transparently. The module can be equipped with two network interfaces in order
to provide channel protection. The second network SFP is not necessary if
protection is not required. In addition the module can be used as bidirectional
single module N-N regenerator. In this case the client SFP may not be
equipped.
Table 459 contains general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 433,839 h
Typ. power consumption (incl. SFPs) 10 W
Max. power consumption (incl. SFPs) 12 W
Maximum RAM consumption on NCU 248 Kbytes
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P
The following table provides a summary of the supported client SFPs. Please
refer to the specifications for the individual SFP type.
SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
SFP/CL/1310I/SM/LC
CWDM SFP/2G5U/CxxxxL/SM/LC
SFP/2G5U/CxxxxV/SM/LC
SFP/FE/C1510U/SM/LC
SFP/FE/C1490U/SM/LC
Electrical types SFP/GBE/ELECTRICAL/RJ45
SFP/3GSDI/ELECTRICAL/DIN1 2
SFP/3GSDI/ELECTRICAL/HBNC1 2
1. WCA-PCN-2G5U with HW rev. 2.01 required.
2. Can be used in transponder mode only.
The following table provides a summary of the supported network SFPs. Please
refer to the specifications for the individual SFP type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Bit Error Ratio <= 10-15 for ESCON
Max. module delay for data 10 ns
rates of 1.25 Gbit/s to 2.7 Gbit/s
Max. module delay for data 50 ns
rates up to 1.06 Gbit/s
Number of regenerations with 15 using WCA-PCN-2G5U as bidirectional
ALS disabled single module N-N regenerator.
Number of regenerations with 3 using WCA-PCN-2G5U as bidirectional
ALS enabled single module N-N regenerator
Max. frame size no limitation
This table shows information about fault monitoring of the module in general.
This table shows information about fault monitoring of the network ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
These tables show information about performance monitoring of the client ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 472: Performance Monitoring Network Interface
Data layer (15 min/24 h records available) Defect seconds (DS)
“10TCE-PCN-16GU+AES100G” on p. 290
“10TCE-PCN-10G+100G-GF” on p. 298
“10TCE-PCN-10G+100G” on p. 305
“5TCE-PCTN-10GU+10G” on p. 313
“5TCE-PCTN-10GU+AES10G” on p. 325
“5TCE-PCTN-8GU+10GS” on p. 337
“5TCE-PCTN-8GU+AES10GS” on p. 345
“5TCE-PCN-10GU+10G” on p. 354
“5TCE-PCN-10GU+AES10G” on p. 364
“4WCE-PCN-16GFC” on p. 374
WCE-PCN-100GB
The WCE-PCN-100GB enterprise transponder provides transport of 100 GbE
client side service in a two-slot module. The client signal is internally mapped
according to G.709 resulting in an OTU4 signal for transport over an enterprise
optical transport network.
The WCE-PCN-100GB transponder module includes a single client side inter-
face and a single network side interface with CFP MSA standard compliant
pluggable transceivers (CFP transceivers). The CFP transceivers perform the
optical-to-electrical and electrical-to-optical conversion function as well as col-
lection of all Physical Layer performance monitorings and Fault monitoring for
each optical lane. The optical performance of the client interface and the net-
work interface is specified by the equipped CFP transceiver module. See the
selected CFP transceiver module specification for additional information.
Enhanced FEC (EFEC-5) is supported on the OTU4 network port to enable
metro reach performance.
The WCE-PCN-100GB provides fault management and performance monitoring
data at the client interface as well as at the network interface for different layers.
The WCE-PCN-100GB supports Client Channel Card Protection (CCCP), 1+1
bidirectional switching.
Table 475 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 475: Module - General Information
Equipment type WCE100GB
First release 12.3
Width 8 HP
Height 5 HU
Weight 1.9 kg (4.19 lbs)
Environmental conditions Operating temperature: +5°C … +40°C
5% ... 85% relative humidity
(non-condensing)
Short-term temperature: -5°C … +40°C
5% ... 90% relative humidity
(non-condensing)
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 426,576 h
Typ. power consumption (incl. CFP 115 W
transceivers)
Max. power consumption (incl. CFP 130 W
transceivers)
Slot positions SH9HU: slots 3...17
SH1HU-HP/2DC, SH1HU-R/PF1,
SH1HU-HP/E-TEMP/2DC: slot 1
NCU types NCU-II, NCU-II-P
Table 477 provides a summary of the supported client CFPs. Please refer to the
specifications for the individual CFP type.
Table 479 provides a summary of the supported network CFPs. Please refer to
the specifications for the individual CFP type.
Table 482 provides information about fault monitoring on the module equipment
level in general.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Voltage Out of Range VOLTANR
Equipment Fault HWFLT
FWP-Mismatch (NSA) FWPM-NSA
FWP-Mismatch (SA) FWPM-SA
Table 483 provides information about fault monitoring of the client ports.
Table 484 provides information about fault monitoring of the network interface.
Table 486 provides information about client service performance monitoring for
the different layers collected for both the receive direction and transmit direction.
Each of these PMs is collected for multiple instances of physical interfaces
supported by the client side CFP pluggable transceiver.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
crossing alerts for OPR too high /
OPR too low)
Optical output power Tx - current, T-OPT-FHT
low, mean, high T-OPT-FLT
(15 min/24 h records available for
PM values except current value; fix
threshold crossing alerts for OPT
too high / OPT too low)
CFP transceiver temperature - T-TEMP-FHT
current analogue value T-TEMP-FLT
(Fix threshold crossing alert for
CFP transceiver temperature too
high/too low available)
Laser bias current level (current LBCL
analogue value)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
user configurable threshold
crossing alerts for BBE too high)
OTU-Skew between Logical Lanes SKEW
(user configurable threshold
crossing alerts for SKEW too high)
ODU4 layer ODU-Errored Seconds ES-ODU
(15 min/24 h records available;
user configurable threshold
crossing alerts for ES too high)
ODU-Severely Errored Seconds SES-ODU
(15 min/24 h records available;
user configurable threshold
crossing alerts for SES too high)
ODU-Unavailable Seconds UAS-ODU
(15 min/24 h records available;
user configurable threshold
crossing alerts for UAS too high)
ODU-Background Block Errors BBE-ODU
(15 min/24 h records available;
user configurable threshold
crossing alerts for BBE too high)
Table 490 provides information about the Embedded Control Channels (ECCs).
WCE-PCN-100G
The WCE-PCN-100G enterprise transponder provides transport of 100 GbE cli-
ent side service in a three-slot module. The client signal is internally mapped
according to G.709 resulting in an OTU4 signal for transport over an enterprise
optical transport network.
The WCE-PCN-100G transponder module includes a single client side interface
and a single network side interface with CFP MSA standard compliant plugga-
ble transceivers (CFP transceivers). The CFP transceivers perform the opti-
cal-to-electrical and electrical-to-optical conversion function as well as collection
of all Physical Layer performance monitorings and Fault monitoring for each
optical lane. The optical performance of the client interface and the network
interface is specified by the equipped CFP transceiver module. See the selected
CFP transceiver module specification for additional information.
Enhanced FEC (EFEC-5) is supported on the OTU4 network port to enable
metro reach performance.
The WCE-PCN-100G provides fault management and performance monitoring
data at the client interface as well as at the network interface for different layers.
The WCE-PCN-100G supports Client Channel Card Protection (CCCP), 1+1
bidirectional switching.
Table 491 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 491: Module - General Information
Equipment type WCE100G
First release 11.2
Width 12 HP
Height 5 HU
Weight 2.25 kg (4.96 lbs)
Environmental conditions Operating temperature: +5°C … +40°C
5% ... 85% relative humidity
(non-condensing)
Short-term temperature: -5°C … +45°C
5% ... 90% relative humidity
(non-condensing)
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 279,876 h
Typ. power consumption (incl. CFP 115 W
transceivers)
Max. power consumption (incl. CFP 135W
transceivers)
Slot positions Only the SH9HU, slots: 3...16
NCU types NCU-II, NCU-II-P
The following table provides a summary of the supported client CFPs. Please
refer to the specifications for the individual CFP type.
The following table provides a summary of the supported network CFPs. Please
refer to the specifications for the individual CFP type.
The following table provides information about the module system performance.
Table 498 provides information about fault monitoring on the module equipment
level in general.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Voltage Out of Range VOLTANR
Equipment Fault HWFLT
FWP-Mismatch (NSA) FWPM-NSA
FWP-Mismatch (SA) FWPM-SA
Table 499 provides information about fault monitoring of the client ports.
Table 500 provides information about fault monitoring of the network interface.
Table 502 provides information about client service performance monitoring for
the different layers collected for both the receive direction and transmit direction.
Each of these PMs is collected for multiple instances of physical interfaces
supported by the client side CFP pluggable transceiver.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
crossing alerts for OPR too high /
OPR too low)
Optical output power Tx - current, T-OPT-FHT
low, mean, high T-OPT-FLT
(15 min/24 h records available for
PM values except current value; fix
threshold crossing alerts for OPT
too high / OPT too low)
CFP transceiver temperature - T-TEMP-FHT
current analogue value T-TEMP-FLT
(Fix threshold crossing alert for
CFP transceiver temperature too
high/too low available)
Laser bias current level (current LBCL
analogue value)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
user configurable threshold
crossing alerts for BBE too high)
OTU-Skew between Logical Lanes SKEW
(user configurable threshold
crossing alerts for SKEW too high)
ODU4 layer ODU-Errored Seconds ES-ODU
(15 min/24 h records available;
user configurable threshold
crossing alerts for ES too high)
ODU-Severely Errored Seconds SES-ODU
(15 min/24 h records available;
user configurable threshold
crossing alerts for SES too high)
ODU-Unavailable Seconds UAS-ODU
(15 min/24 h records available;
user configurable threshold
crossing alerts for UAS too high)
ODU-Background Block Errors BBE-ODU
(15 min/24 h records available;
user configurable threshold
crossing alerts for BBE too high)
The following table provides information about the Embedded Control Channels
(ECCs).
10TCE-PCN-16GU+AES100G
The 10TCE-PCN-16GU+AES100G module is a 100G enterprise type TDM
channel module with ten cages for client side SFP+ pluggable transceivers and
a single cage for a network side CFP pluggable transceiver. The module
supports encrypting of 100Gbit/s, is designed according to FIPS Publication
140-2 with security level 2, and can be used for the transport of security-related
data. The aggregated data stream is encrypted/decrypted using the Advanced
Encryption Standard (AES). Data encryption and the use of an endpoint
authentication mechanism protect the network link between two communicating
10TCE-PCN-16GU+AES100G modules against man-in-the-middle attacks.
Table 507 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Environmental conditions for ETSI EN 300 019-1-3 Class 3.1e
SH9HU and SH1HU-R/PF Operating temperature: +5°C … +40°C
5% ... 85% relative humidity
(non-condensing)
SFP+CDR/11GU/CxxxxS/SM/LC2
1. Released for 16G FC operation only
2. Intended to be used only to connect to 40GBASE-LR4 using
J/SM/4CS-#C1270-#C1330/LC breakout cable
Table 511 provides a summary of the supported CFP network transceiver types.
Please refer to the specifications for the individual CFP transceiver type.
Table 513 provides information about the operation mode and supported client
services.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 514 provides information about the mapping and multiplexing schemes.
PS
following tables are applicable for a specific deployment depends
on the configuration of the respective interface.
Note
Table 516 provides information about fault monitoring on the module equipment
level in general.
Table 517 provides information about fault monitoring of the client ports.
Table 518 provides information about fault monitoring of the network port.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Locked LCK-ODU
OPU layer Client signal fail CSF-OPU
Proprietary provisioning payload PPLM-OPU
mismatch
Auto shutdown - transmitting client signal LKDO-CSF
fail
1. One instance supported per optical lane as well as a single instance
supported for the aggregate status of all optical lanes.
Table 521 provides information about performance monitoring for the different
layers collected for both the receive direction and transmit direction. Each of
these PMs is collected for multiple instances of physical interfaces supported by
the network side CFP pluggable transceiver.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
alerts for CE too high)
FEC-Uncorrectable block errors UBE-FEC
(15 min/24 h records available; user
configurable threshold crossing
alerts for UBE too high)
pre-FEC BER BERCE-FEC
OTU4 layer OTU-Errored Seconds ES-OTU
(15 min/24 h records available; user
configurable threshold crossing
alerts for ES too high)
OTU-Severely Errored Seconds (15 SES-OTU
min/24 h records available; user
configurable threshold crossing
alerts for SES too high)
OTU-Unavailable Seconds UAS-OTU
(15 min/24 h records available; user
configurable threshold crossing
alerts for UAS too high)
OTU-Background Block Errors BBE-OTU
(15 min/24 h records available; user
configurable threshold crossing
alerts for BBE too high)
OTU-Skew between Logical Lanes SKEW
(user configurable threshold crossing
alerts for SKEW too high)
Table 525 provides information about the Embedded Control Channels (ECCs).
10TCE-PCN-10G+100G-GF
The 10TCE-PCN-10G+100G-GF is a 100G enterprise type TDM channel
module with ten SFP+ interfaces on the client side (10x10G) and a single CFP
interface on the network side. This module supports ODU4 according to ITU-T
G.709 with reduced functionality, ODUflex and GMP. It can map combinations
of up to ten 10Gbit/s client signals into an OTU4 interface. The aggregate 100G
service signal (OTU4) is transmitted at a data rate of 111.81Gbit/s using the
multi-lane concept according to the above-mentioned standard. G.709 standard
FEC (GFEC) is provided on the network interface.
The 10TCE-PCN-10G+100G-GF supports versatile switched protection.
Performance monitoring and fault management of physical layer alarms and
service-related alarms are also supported.
Table 526 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
(non-condensing)
Short-term temperature1: -5°C...+50°C
5% ... 90% relative humidity
(non-condensing)
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient 307,314 h
temperature
Typ. power consumption (incl. 80 W
pluggable transceivers)
Max. power consumption (incl. 100 W
pluggable transceivers)
Slot positions SH9HU: slots 3...17
SH1HU-HP/2DC, SH1HU-R/PF,
SH1HU-HP/E-TEMP/2DC: slot 1
NCU types NCU-II, NCU-II-P
1. The maximum short-term temperature in an SH1HU-HP/2DC is restricted to
45°C.
The following table provides a summary of the supported SFP+ client trans-
ceiver types. Please refer to the specifications for the individual SFP+ trans-
ceiver type.
Protocol OTU4
Maximum skew 500 ns
The following table provides a summary of the supported CFP network trans-
ceiver types. Please refer to the specifications for the individual CFP transceiver
type.
The following table provides information about the operation modes and sup-
ported client services.
Table below provides information about the mapping and multiplexing schemes.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Note
The following table provides information about fault monitoring on the module
equipment level in general.
The following table provides information about fault monitoring of the client ports
in ingress direction.
The following table provides information about fault monitoring of the client ports
in egress direction.
The following table provides information about fault monitoring of the network
interface in ingress direction. All conditions applying to the physical layer
including the TCA on the performance of the optical lanes will be reported N
times
(N = number of physical interfaces on the pluggable CFP transceiver module).
The following table provides information about fault monitoring of the network
interface in egress direction. All conditions applying to the physical layer includ-
ing the TCA on the performance of the optical lanes will be reported N times (N
= number of physical interfaces on the pluggable CFP transceiver module).
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
temperature too high/too low TCA thresholds)
The following table provides information about the Embedded Control Channels
(ECCs).
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
10TCE-PCN-10G+100G
The 10TCE-PCN-10G+100G is a 100G enterprise type TDM channel module
with ten SFP+ interfaces on the client side (10x10G) and a single CFP interface
on the network side. This module supports ODU4 according to ITU-T G.709 with
reduced functionality, ODUflex and GMP. It can map combinations of up to ten
10Gbit/s client signals into an OTU4 interface. The aggregate 100G service sig-
nal (OTU4) is transmitted at a data rate of 111.81Gbit/s using the multi-lane con-
cept according to the above-mentioned standard. Enhanced FEC (EFEC-5)
optimized for minimum latency is provided on the network interface.
Performance monitoring and fault management of physical layer alarms and
service-related alarms are supported.
Table 547 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Maximum skew 500 ns
The following table provides information about the operation modes and sup-
ported client services.
Table below provides information about the mapping and multiplexing schemes.
The following table provides information about fault monitoring on the module
equipment level in general.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table provides information about fault monitoring of the client ports
in ingress direction.
The following table provides information about fault monitoring of the client ports
in egress direction.
The following table provides information about fault monitoring of the network
interface in ingress direction. All conditions applying to the physical layer includ-
ing the TCA on the performance of the optical lanes will be reported N times (N
= number of physical interfaces on the pluggable CFP transceiver module).
The following table provides information about fault monitoring of the network
interface in egress direction. All conditions applying to the physical layer includ-
ing the TCA on the performance of the optical lanes will be reported N times (N
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table provides information about performance monitoring values
supported on the client interfaces in egress direction.
The following table provides information about the Embedded Control Channels
(ECCs).
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
5TCE-PCTN-10GU+10G
The 5TCE-PCTN-10GU+10G module is a 5-port TDM channel module with
pluggable client interfaces and one DWDM network interface.
The module can operate in three different modes:
• TDM mode
o
Transparent multiplexer mode:
The incoming data stream is mapped bit for bit in a simplified G.709
frame. The client ports support 1G FC, 2G FC, 4G FC, 5G IB and 1GbE.
The data rate on the network port depends on the application. Transport
of 5G IB services is supported in the TDM mode multiplexing up to 2 x
5G IB. 5G IB transport requires the use of the appropriate SFP+ devices
in the client interfaces C1 and C2.
o Framed mode:
In framed mode the physical coding sublayer (PCS) is terminated. The
8B/10B coding is removed prior to multiplexing. Rate adaption is
performed through byte stuffing. The client ports support 1G FC, 2G FC,
4G FC, 8G FC and 1GbE. 8G FC can be applied at client port 1 only.
• Transparent transponder mode:
This mode is similar to the transparent multiplexer mode, but it allows to
transport 8G FC, 10G FC, 10GbE LAN and 10G IB as single service only
applied at client port 1.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table provides information about the client ports for all variants.
This table provides a summary of the supported client SFPs. Please refer to the
specifications for the individual SFP type.
Table 570: Supported Client SFPs for all Variants
850 nm types SFP/2G1/850I/MM/LC
SFP/4GU/850I/MM/LC
SFP+/8GU/850I/MM/LC (client port 1)
SFP+/10G/850I/MM/LC (client ports 1 and 2)
SFP+/11GU/850I/MM/LC
1310 nm types SFP/HS/1310S/SM/LC
SFP/CL/1310I/SM/LC
SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
SFP/4GU/1310S/SM/LC
SFP+/8GU/1310S/SM/LC (client port 1)
SFP+/10G/1310S/SM/LC (client ports 1 and 2)
SFP+/11GU/1310S/SM/LC
SFP/GBE/B1310S/SM/LC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFP/GBE/B1310L/SM/LC
1490 nm types SFP/GBE/B1490L/SM/LC
SFP/GBE/B1490S/SM/LC
The following table provides information about the network port for all variants.,
Table 571: Network Port - General Information for all Variants
Number of network ports 1
Type of network port Tunable DWDM interface
Optical connector type LC
Fiber type SM 9 µm
Data rates 10.9747 Gbit/s for 8G FC,
(transparent transponder mode) 10.7595 Gbit/s for 10G IB,
11.0957Gbit/s for 10 GbE,
11.3176 Gbit/s for 10G FC
Data rates (Multiplexer mode, transparent as 11.3176 Gbit/s
well as framed)
Protocols Subset G.709 OTU2
Tuning time (any channel to any ch.) < 45 s
Tuning time cold start (any channel to any < 60 s
channel)
Max. shuttered output power (dark tuning) -30 dBm
The following table provides information about the network port for the
5TCE-PCTN-10GU-LN#DC.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmitter output power range -3 dBm ... 0 dBm
Transmitter wavelength range 81 channels, 50 GHz spacing in C
band acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 60 pm
Min. extinction ratio 11 dB at 10.7595 Gbit/s
10 dB at 11.3176 Gbit/s
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -14 dBm ... -1 dBm
Receiver dynamic range for operation -16 dBm ...-1 dBm
with FEC starting Rel. 10.2
OPR measurement range -18 dBm ... +2 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range -300 ps/nm ... +300 ps/nm
Dispersion load range with 1 dB -500 ps/nm ... -300 ps/nm and
OSNR penalty +300 ps/nm ... +500 ps/nm
Dispersion load range with 2 dB -700 ps/nm ... -500 ps/nm and
OSNR penalty +500 ps/nm ... +700 ps/nm
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)
OSNR penalty at -16 dBm Rx input 1 dB
power for operation without FEC or
with FEC up to Rel. 10.2
This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-10GU-LN#DC.
The following table provides information about the network port for the
5TCE-PCTN-10GU+10G-V#DC.
This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-10GU+10G-V#DC.
The following table provides information about the network port for the
5TCE-PCTN-10GU+10G-V#DL.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
OPR measurement range -22 dBm ... -5 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range +200 ps/nm ... +800 ps/nm
Dispersion load range with 1dB -100 ps/nm ... +200 ps/nm and
OSNR penalty +800 ps/nm ... +1100 ps/nm
Dispersion load range with 2dB -400 ps/nm ... -100 ps/nm and
OSNR penalty +1100 ps/nm ... +1400 ps/nm
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)
OSNR penalty at 10.9747 Gbit/s, 1 dB
11.0957Gbit/s and 11.3176 Gbit/s
This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-10GU+10G-V#DL.
Table 577: Bit Error Rate Versus OSNR for 5TCE-PCTN-10GU+10G-V#DL
Pre-FEC Bit Error Ratio < 10-12 at 25 dB OSNR at 0.1 nm
< 10-9 at 23 dB OSNR at 0.1 nm
< 10-5 at 19 dB OSNR at 0.1 nm
This table shows the recommended maximum pre-FEC bit error ratio for all
variants.
The following table provides information about the operation modes for all
variants.
1G FC = 2 VC
(starting at VC number 1 through 11 only)
2G FC = 3 VC
(starting at VC number 1 through 10 only)
4G FC = 5 VC
(starting at VC number 1 through 8 only)
5G IB = 6VC
(starting at VC number 1, 7 only)
Framed mode Support of 12 virtual containers (VC).
Number of concatenated VCs needed:
1G FC = 1 VC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
(starting at every VC number possible)
2G FC or 1GbE = 2 VC
(starting at VC number 1, 3, 5, 7, 9, 11 only)
4G FC = 4 VC
(starting at VC number 1, 5, 9 only)
8G FC = 8 VC
(starting at VC number 1, 5 only)
Mapping / Framing Mapping into proprietary used
OPU2 / ODU2 framing acc. to ITU-T G.709.
Max. frame size for
FC services < 2200 bytes
GbE services 9600 bytes
This table contains information about the system performance for all variants.
This table shows information about fault monitoring of the module in general for
all variants.
This table shows information about fault monitoring of the client ports in general
for all variants.
Table 582: Fault Monitoring Client Interface - General for all Variants
Physical layer Laser failure;
Laser degrade (based on bias current);
Loss of signal (LOS)
This table shows information about fault monitoring of the client ports in ingress
direction for all variants.
Table 583: Fault Monitoring Client Interface - Ingress Direction for all
Variants
Physical coding sublayer (PCS) Loss of character synchronization1
1. Only supported in framed mode.
This table shows information about fault monitoring of the network ports for all
variants.
Table 584: Fault Monitoring Network Interface - General for all Variants
Physical layer Laser failure;
Receiver clock synch failure;
Loss of signal (LOS)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table provides information about fault monitoring of the network ports in
egress direction for all variants.
Table 585: Fault Monitoring Network Interface - Egress Direction for all
Variants
OCH/OTU2 layer LOF
OPU2 layer AIS
Proprietary aggregate VF layer SSF-VF; AIS-VF
This table shows information about performance monitoring of the client ports
for all variants.
Table 587: Performance Monitoring Client Interface - Ingress Direction for all
Variants
Physical layer Transmitter bias current
(15 min/24 h records available for PM values (current); Optical power
except current values; user configurable threshold Rx (current, low, mean,
crossing alerts for OPR too high/too low available; high); Optical power Tx
fix threshold crossing alerts for OPT too high/too (current, low, mean, high);
low available) Latency (current, low,
mean, high)
Physical coding sublayer CV; DE; ES1
(15 min/24 h records with user configurable
threshold crossing alerts available)
1. CV, DE and ES - only supported in framed mode
This table shows information about performance monitoring of the network ports
for all variants.
This table provides information about the loop functionality for all variants.
This table shows information about protection setting for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
5TCE-PCTN-10GU+AES10G
The 5TCE-PCTN-10GU+AES10G module is a 5-port TDM channel module with
five pluggable client interfaces and one DWDM network interface supporting
data encryption. The module is designed according to FIPS Publication 140-2
with security level 2, and can be used for the transport of security-related data.
The aggregated data stream is encrypted/decrypted using the Advanced
Encryption Standard (AES). Data encryption and the use of an endpoint
authentication mechanism protect the network link between two communicating
5TCE-PCTN-10GU+AES10G modules against man-in-the-middle attacks.
The module can operate in following modes:
• TDM mode
o Transparent multiplexer mode:
The incoming data stream is mapped bit for bit in a simplified G.709
frame. The client ports support 1G FC, 2G FC, F2488, 4G FC, 5G IB
and 1GbE. The data rate on the network port depends on the
application. Transport of 5G IB services is supported in the TDM mode
multiplexing up to 2 x 5G IB. 5G IB transport requires the use of the
appropriate SFP+ devices in the client interfaces C1 and C2.
o Framed mode:
In framed mode the physical coding sublayer (PCS) is terminated. The
8B/10B coding is removed prior to multiplexing. Rate adaption is
performed through byte stuffing. The client ports support 1G FC, 2G FC,
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 593 contains general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SH1HU-HP/E-TEMP/2DC Short-term temperature: -5°C … +45°C
5% ... 90% relative humidity
(non-condensing)
Environmental conditions for Operating temperature: +5°C … +40°C
SH1HU-R/PF 5% ... 85% relative humidity
(non-condensing)
The following table provides information about the client ports for all variants.
This table provides a summary of the supported client SFPs. Please refer to the
specifications for the individual SFP type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table provides information about the network port for all variants.
Table 596: Network Port - General Information for all Variants (Continued)
Data rates 10.9747 Gbit/s for 8G FC,
(transparent transponder mode) 10.7092 Gbit/s for F9953,
10.7595 Gbit/s for 10G IB,
11.0957Gbit/s for 10 GbE,
11.3176 Gbit/s for 10G FC
Data rates 11.3176 Gbit/s
(Multiplexer mode, transparent as
well as framed)
Protocols Subset G.709 OTU2
Tuning time (any channel to any ch.) < 45 s
Tuning time cold start (any channel < 60 s
to any channel)
Maximum shuttered output power -30 dBm
(dark tuning)
Table below provides information about encryption on the network port for all
variants.
Table 597: Network Port - Encryption for all Variants
Encryption of payload acc. Advanced Encryption Standard
with 256 bit key in counter mode
Module design acc. NIST FIPS 140-2 “Security
Requirements for Cryptographic
Modules” - security level 2
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Key exchange (hardware true every 10 minutes
random number generator)
Typ. initial key exchange before < 3 min
data transmission
Far-end authentication PACE protocol
Key exchange with Diffie-Hellman Diffie-Hellman group #5 from RFC3526
with 1536 bit key length
The following table provides information about the network port for the
5TCE-PCTN-10GU+AES10G-LN#DC.
This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-10GU+AES10G-LN#DC.
Pre-FEC Bit Error Ratio for operation < 10-9 at 19 dB OSNR at 0.1 nm
with FEC
< 10-5 at 15 dB OSNR at 0.1 nm
The following table provides information about the network port for the
5TCE-PCTN-10GU+AES10G-V#DC.
This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-10GU+AES10G-V#DC.
The following table provides information about the network port for the
5TCE-PCTN-10GU+AES10G-V#DL.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
band acc. to ITU-T G.694 (tunable)
Wavelength stability (operating) +/- 100 pm
Min. extinction ratio 10 dB
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -20 dBm ... -8 dBm
OSNR penalty at -22 dBm Rx input 1 dB
power
OPR measurement range -22 dBm ... -5 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range +200 ps/nm ... +800 ps/nm
Dispersion load range with 1dB -100 ps/nm ... +200 ps/nm and
OSNR penalty +800 ps/nm ... +1100 ps/nm
Dispersion load range with 2dB -400 ps/nm ... -100 ps/nm and
OSNR penalty +1100 ps/nm ... +1400 ps/nm
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)
OSNR penalty at 10.9747 Gbit/s, 1 dB
11.0957Gbit/s and 11.3176 Gbit/s
This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-10GU+AES10G-V#DL.
This table shows the recommended maximum pre-FEC bit error ratio for all
variants.
Table below provides information about the operation modes for all variants.
1G FC = 2 VC
(starting at VC number 1 through 11 only)
2G FC, F2488 = 3 VC
(starting at VC number 1 through 10 only)
4G FC = 5 VC
(starting at VC number 1 through 8 only)
5G IB = 6VC
(starting at VC number 1, 7 only)
Framed mode Support of 12 virtual containers (VC).
Number of concatenated VCs needed:
1G FC = 1 VC
(starting at every VC number possible)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
2G FC or 1GbE = 2 VC
(starting at VC number 1, 3, 5, 7, 9, 11 only)
4G FC = 4 VC
(starting at VC number 1, 5, 9 only)
8G FC = 8 VC
(starting at VC number 1, 5 only)
Mapping / Framing Mapping into proprietary used
OPU2 / ODU2 framing acc. to ITU-T G.709.
Max. frame size for
FC services < 2200 bytes
GbE services 9600 bytes
This table contains information about the system performance for all variants.
XFP/11G/Dxxxx.xxV/SM/LC#Dxx and
XFP/11G/DCTV/SM/LC supporting data rates
between 9.9532 Gbit/s and 11.3176 Gbit/s at a
max. ambient temperature of 45°C1
1. In this application the 2WCA-PCN-10G has to be provisioned to a data rate
between 9.9532 Gbit/s and 10.709 Gbit/s even if the transported data rate is
higher.
This table shows information about fault monitoring of the module in general for
all variants.
This table shows information about fault monitoring of the client ports in general
for all variants.
Table 608: Fault Monitoring Client Interface - General for all Variants
Physical layer Laser failure;
Laser degrade (based on bias current);
Loss of signal (LOS)
This table shows information about fault monitoring of the client ports in ingress
direction for all variants.
Table 609: Fault Monitoring Client Interface - Ingress Direction for all
Variants
Physical coding sublayer (PCS) Loss of character synchronization1
1. Only supported in framed mode.
This table shows information about fault monitoring of the network ports for all
variants.
Table 610: Fault Monitoring Network Interface - General for all Variants
Physical layer Laser failure;
Receiver clock synch failure;
Loss of signal (LOS)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table provides information about fault monitoring of the network ports in
egress direction for all variants.
Table 611: Fault Monitoring Network Interface - Egress Direction for all
Variants
OCH/OTU2 layer LOF
OPU2 layer AIS
Proprietary aggregate VF layer SSF-VF; AIS-VF
This table shows information about performance monitoring of the client ports
for all variants.
Table 613: Performance Monitoring Client Interface - Ingress Direction for all
Variants
Physical layer Transmitter bias current
(15 min/24 h records available for PM values (current); Optical power
except current values; user configurable threshold Rx (current, low, mean,
crossing alerts for OPR too high/too low available; high); Optical power Tx
fix threshold crossing alerts for OPT too high/too (current, low, mean, high);
low available) Latency (current, low,
mean, high)
Physical coding sublayer CV; DE; ES1
(15 min/24 h records with user configurable
threshold crossing alerts available)
1. CV, DE and ES - only supported in framed mode
This table shows information about performance monitoring of the network ports
for all variants.
This table provides information about the loop functionality for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table shows information about protection setting for all variants.
5TCE-PCTN-8GU+10GS
The 5TCE-PCTN-8GU+10GS module is a 5-port TDM channel module with five
pluggable client interfaces and one DWDM network interface.
The module can operate in following TDM modes:
• Transparent multiplexer mode:
The incoming data stream is physically terminated and mapped bit for bit
into VC4-64c or STS192c payload, and then mapped into STM64 or OC192
framing structure with reduced functionality according to ITU-T G.707 or
Telcordia GR-253. The client ports support 1G FC, 2G FC, 4G FC and
1GbE.
• Framed mode:
In framed mode the physical coding sublayer (PCS) is terminated. The
8B/10B coding is removed prior to multiplexing. Rate adaption is performed
through byte stuffing. The client ports support 1G FC, 2G FC, 4G FC, 8G FC
and 1GbE. 8G FC can be applied at client port 1 only.
The 5TCE-PCTN-8GU+10GS is available in two variants:
• 5TCE-PCTN-8GU+10GS-LN#DC
• 5TCE-PCTN-8GU+10GS-V#DC
The 5TCE-PCTN-8GU+10GS-V#DC has very long reach network interfaces.
The 5TCE-PCTN-8GU+10GS-LN#DC features a long reach noise optimized
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
network interface, which has a high extinction ratio suitable for links with a large
amount of amplifiers and low OSNR.
Table 620 contains general information about the module and its environment.
The following table provides information about the client ports for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Data rates (framed mode), client 8.5 Gbit/s
port C1 only
Protocols (transparent multiplexer GbE, 1G FC, 2G FC (incl. 2G Coupling
mode) Link), 4G FC
Protocols (framed mode) GbE, 1G FC, 2G FC, 4G FC, 8G FC
This table provides a summary of the supported client SFPs. Please refer to the
specifications for the individual SFP type.
Table 622: Supported Client SFPs for all Variants
850 nm types SFP/2G1/850I/MM/LC
SFP/4GU/850I/MM/LC
SFP+/8GU/850I/MM/LC (client port 1)
SFP+/11GU/850I/MM/LC
1310 nm types SFP/HS/1310S/SM/LC
SFP/CL/1310I/SM/LC
SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
SFP/4GU/1310S/SM/LC
SFP+/8GU/1310S/SM/LC (client port 1)
SFP+/11GU/1310S/SM/LC
SFP/GBE/B1310S/SM/LC
SFP/GBE/B1310L/SM/LC
1490 nm types SFP/GBE/B1490L/SM/LC
SFP/GBE/B1490S/SM/LC
The following table provides information about the network port for all variants.
Table 623: Network Port - General Information for all Variants
Number of network ports 1
Type of network port Tunable DWDM interface
Optical connector type LC
Fiber type SM 9 µm
Data rates (multiplexer and framed mode) 9.95328 Gbit/s
Protocols STM-64, OC-192
Tuning time (any channel to any ch.) < 45 s
Tuning time cold start (any channel to any < 60 s
channel)
Max. shuttered output power (dark tuning) -30 dBm
The following table provides information about the network port for the
5TCE-PCTN-8GU+10GS-LN#DC.
This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-8GU+10GS-LN#DC.
The following table provides information about the network port for the
5TCE-PCTN-8GU+10GS-V#DC.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
(outage probability 4x10-5)
This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-8GU+10GS-V#DC.
The following table provides information about the operation modes for all
variants.
1G FC = 2 VC
(starting at VC number 1 through 10 only)
2G FC = 3 VC
(starting at VC number 1 through 9 only)
4G FC = 5 VC
(starting at VC number 1 through 7 only)
Framed mode Support of 11 virtual containers (VC).
Number of concatenated VCs needed:
1G FC = 1 VC
(starting at every VC number possible)
2G FC or 1GbE = 2 VC
(starting at VC number 1, 3, 5, 7, 9 only)
4G FC = 4 VC
(starting at VC number 1, 5 only)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
8G FC = 8 VC
(starting at VC number 1, 4 only)
Mapping / Framing Mapping into proprietary used
STM-64 framing acc. to ITU-T G.707 and
OC-192 according GR-253
Max. frame size for
FC services 2148 bytes
GbE services 9600 bytes
This table contains information about the system performance for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Note
This table shows information about fault monitoring of the module in general for
all variants.
This table shows information about fault monitoring of the client ports in general
for all variants.
Table 631: Fault Monitoring Client Interface - General for all Variants
Physical layer Laser failure;
Laser degrade (based on bias current)
Loss of signal (LOS);
Auto shutdown (laser off condition);
Physical coding sublayer Loss of character synchronization1;
Auto shutdown - transmitting error
propagation code condition
1. Only supported in framed mode.
This table provides information about fault monitoring of the network ports in
general for all variants.
Table 632: Fault Monitoring Network Interface - General for all Variants
Physical layer Laser failure; Receiver clock synch failure;
Loss of signal (LOS)
SDH/SONET layer LOF; AIS; RDI; SD; LOP; UNEQ; PLM; RDI
Proprietary aggregate VF layer SSF; AIS; LKDO-AIS, SGEO-LASER
This table shows information about performance monitoring of the client ports
for all variants.
Table 634: Performance Monitoring Client Interface - General for all Variants
Physical layer (15 min/24 h records available for Transmitter bias current
PM values except current values; user (current); Optical power
configurable threshold crossing alerts for OPR too Rx (current, low, mean,
high/too low available; fix threshold crossing high); Optical power Tx
alerts for OPT too high/too low available) (current, low, mean, high)
Physical coding sublayer CV; DE; ES1
(15 min/24 h records with user configurable
threshold crossing alerts available)
1. CV, DE and ES - only supported in framed mode
This table shows information about performance monitoring of the network ports
for all variants.
This table provides information about the loop functionality for all variants.
This table shows information about protection setting for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 637: Protection Switching for all Variants
Protection scheme Versatile switched protection
(RSM-SF, RSM-OLM, VSM)
Protection switching time < 50 ms
5TCE-PCTN-8GU+AES10GS
The 5TCE-PCTN-8GU+AES10GS module is a 5-port TDM channel module with
five pluggable client interfaces and one DWDM network interface supporting
data encryption. The module is designed according to FIPS Publication 140-2
with security level 2, and can be used for the transport of security-related data.
The aggregated data stream is encrypted/decrypted using the Advanced
Encryption Standard (AES). Data encryption and the use of an endpoint
authentication mechanism protect the network link between two communicating
5TCE-PCTN-8GU+AES10GS modules against man-in-the-middle attacks.
The module can operate in following TDM modes:
• Transparent multiplexer mode:
The incoming data stream is physically terminated and mapped bit for bit
into VC4-64c or STS192c payload, and then mapped into STM64 or OC192
framing structure with reduced functionality according to ITU-T G.707 or
Telcordia GR-253. The client ports support 1G FC, 2G FC, 4G FC and
1GbE. The data rate on the network port depends on the application.
• Framed mode:
In framed mode the physical coding sublayer (PCS) is terminated. The
8B/10B coding is removed prior to multiplexing. Rate adaption is performed
through byte stuffing. The client ports support 1G FC, 2G FC, 4G FC, 8G FC
and 1GbE. 8G FC can be applied at client port 1 only.
The 5TCE-PCTN-8GU+AES10GS is available in two variants:
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• 5TCE-PCTN-8GU+AES10GS-LN#DC
• 5TCE-PCTN-8GU+AES10GS-V#DC
The 5TCE-PCTN-8GU+AES10GS-V#DC has very long reach network
interfaces.
The 5TCE-PCTN-8GU+AES10GS-LN#DC features a long reach noise
optimized network interface, which has a high extinction ratio suitable for links
with a large amount of amplifiers and low OSNR.
Table 639 contains general information about the module and its environment.
The following table provides information about the client ports for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Type of client ports SFP (client ports 1 to 5)
SFP+ (client port 1 only)
Data rates (transparent multiplexer 1.250 Gbit/s, 1.0625 Gbit/s,
mode) 2.125 Gbit/s, 4.250 Gbit/s
Data rates (framed mode) 1.250 Gbit/s, 1.0625 Gbit/s,
2.125 Gbit/s, 4.250 Gbit/s
Data rates (framed mode), client 8.5 Gbit/s
port C1 only
Protocols (transparent multiplexer GbE, 1G FC, 2G FC (incl. 2G Coupling
mode) Link), 4G FC
Protocols (framed mode) GbE, 1G FC, 2G FC, 4G FC, 8G FC
This table provides a summary of the supported client SFPs. Please refer to the
specifications for the individual SFP type.
Table 641: Supported Client SFPs for all Variants
850 nm types SFP/2G1/850I/MM/LC
SFP/4GU/850I/MM/LC
SFP+/8GU/850I/MM/LC (client port 1)
SFP+/11GU/850I/MM/LC (client port 1)
1310 nm types SFP/HS/1310S/SM/LC
SFP/CL/1310I/SM/LC
SFP/2G5U/1310S/SM/LC
SFP/2G5U/1310L/SM/LC
SFP/4GU/1310S/SM/LC
SFP+/8GU/1310S/SM/LC (client port 1)
SFP+/11GU/1310S/SM/LC (client port 1)
The following table provides information about the network port for all variants.
Table 642: Network Port - General Information for all Variants
Number of network ports 1
Type of network port Tunable DWDM interface
Optical connector type LC
Fiber type SM 9 µm
Data rates (multiplexer and framed mode) 9.95328 Gbit/s
Protocols STM-64, OC-192
Tuning time (any channel to any ch.) < 45 s
Tuning time cold start (any channel to any channel) < 60 s
Max. shuttered output power (dark tuning) -30 dBm
Table below provides information about encryption on the network port for all
variants.
The following table provides information about the network port for the
5TCE-PCTN-8GU+AES10GS-LN#DC.
This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-8GU+10GS-LN#DC.
The following table provides information about the network port for the
5TCE-PCTN-8GU+10GS-V#DC.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Min. sidemode suppression ratio 40 dB
Receiver wavelength range 1529 nm ... 1604 nm
Receiver dynamic range -20 dBm ... -8 dBm
OSNR penalty at -22 dBm Rx input 1 dB
power
OPR measurement range -22 dBm ... -5 dBm
OPR/OPT accuracy +/- 2 dB
Optimum dispersion load range +200 ps/nm ... +800 ps/nm
Dispersion load range with 1dB OSNR -100 ps/nm ... +200 ps/nm and
penalty +800 ps/nm ... +1100 ps/nm
Dispersion load range with 2dB OSNR -400 ps/nm ... -100 ps/nm and
penalty +1100 ps/nm ... +1400 ps/nm
OSNR PMD penalty 1 dB at 10 ps
(outage probability 4x10-5)
This table contains information about the bit error rate versus OSNR for
5TCE-PCTN-8GU+10GS-V#DC.
Table below provides information about the operation modes for all variants.
1G FC = 2 VC
(starting at VC number 1 through 10 only)
2G FC = 3 VC
(starting at VC number 1 through 9 only)
4G FC = 5 VC
(starting at VC number 1 through 7 only)
Framed mode Support of 11 virtual containers (VC).
Number of consecutive VCs needed:
1G FC = 1 VC
(starting at every VC number possible)
2G FC or 1GbE = 2 VC
(starting at VC number 1, 3, 5, 7, 9 only)
4G FC = 4 VC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
8G FC = 8 VC
(starting at VC number 1, 4 only)
Mapping / Framing Mapping into proprietary used STM-64
framing acc. to ITU-T G.707 and OC-192
according GR-253
Max. frame size for
FC services 2148 bytes
GbE services 9600 bytes
This table contains information about the system performance for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Whether fault/performance monitoring entries listed in the
PS
This table shows information about fault monitoring of the module in general for
all variants.
This table shows information about fault monitoring of the client ports in general
for all variants.
Table 651: Fault Monitoring Client Interface - General for all Variants
Physical layer Laser failure;
Laser degrade (based on bias current)
Loss of signal (LOS);
Auto shutdown (laser off condition);
Physical coding sublayer Loss of character synchronization1;
Auto shutdown - transmitting error
propagation code condition
1. Only supported in framed mode.
This table provides information about fault monitoring of the network ports in
general for all variants.
Table 652: Fault Monitoring Network Interface - General for all Variants
Physical layer Laser failure; Receiver clock synch failure;
Loss of signal (LOS)
SDH/SONET layer LOF; AIS; RDI; SD; LOP; UNEQ; PLM; RDI
Proprietary VF layer SSF; AIS; LKDO-AIS, SGEO-LASER
This table shows information about performance monitoring of the client ports
for all variants.
Table 654: Performance Monitoring Client Interface - General for all Variants
Physical layer Transmitter bias current
(15 min/24 h records available for PM values (current); Optical power
except current values; user configurable threshold Rx (current, low, mean,
crossing alerts for OPR too high/too low available; high); Optical power Tx
fix threshold crossing alerts for OPT too high/too (current, low, mean, high)
low available)
Physical coding sublayer CV; DE; ES1
(15 min/24 h records with user configurable
threshold crossing alerts available)
1. CV, DE and ES - only supported in framed mode
This table shows information about performance monitoring of the network ports
for all variants.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
last failed Crypto-Officer password
timer (countdown) remaining session- key lifetime
remaining time running in bypass mode
This table provides information about the loop functionality for all variants.
This table shows information about restoration setting for all variants.
5TCE-PCN-10GU+10G
The 5TCE-PCN-10GU+10G module is a 5-port 10G enterprise type TDM
channel module with five SFP/SFP+ interfaces on the client side and a single
SFP+ interface on the network side.
The module can operate in following modes:
• TDM mode
o
Transparent multiplexer mode:
The incoming data stream is mapped bit for bit in a simplified G.709
frame. The client ports support 1G FC, 2G FC, F2488 (STM16/OC-48),
4G FC, 5G IB, and 1GbE. The data rate on the network port depends on
the application. Transport of 5G IB services is supported in the TDM
mode multiplexing up to 2 x 5G IB. 5G IB transport requires the use of
the appropriate SFP+ devices in the client interfaces C1 and C2.
o Framed mode:
In framed mode the physical coding sublayer (PCS) is terminated. The
8B/10B coding is removed prior to multiplexing. Rate adaption is
performed through byte stuffing. The client ports support 1G FC, 2G FC,
4G FC, 8G FC and 1GbE. 8G FC can be applied at client port 1 only.
• Transparent transponder mode:
This mode is similar to the transparent multiplexer mode, but it allows to
transport 8G FC, F9953 (STM64/OC-192), 10G FC, and 10GbE LAN as
single service only applied at client port 1.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 660 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
(multiplexer mode, transparent as well as
framed)
Protocols Subset G. 709 OTU2
1G FC = 2 VC
(starting at VC number 1 through 11 only)
2G FC, F2488 = 3 VC
(starting at VC number 1 through 10 only)
4G FC = 5 VC
(starting at VC number 1 through 8 only)
5G IB = 6VC
(starting at VC number 1, 7 only)
Framed mode Support of 12 virtual containers (VC).
Number of concatenated VCs needed:
1G FC = 1 VC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
10.709 Gbit/s and 11.0957 Gbit/s;
For these data rates the module can interwork
with the 10TCC-PCTN-100G as OTU2
aggregator.
Table 667 provides information about the multiplexing and mapping schemes.
Table 668 provides information about fault monitoring on the module equipment
level in general.
Table 669 provides information about fault monitoring of the client interfaces.
Table 670 provides information about fault monitoring of the network interface.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
value; user configurable
threshold crossing alerts for
OPR too high / OPR too low)
Optical output power Tx - T-OPT-FHT
current, low, mean, high T-OPT-FLT
(15 min/24 h records available
for PM values except current
value; fix threshold crossing
alerts for OPT too high / OPT
too low)
SFP/SFP+ T-TEMP-FHT
current analogue value T-TEMP-FLT
(Fix threshold crossing alert for
CFP transceiver temperature
too high/too low available)
Laser bias current level LBCL
(current analogue value)
Latency - measured round trip T-LATENCY-HT
client-to-client T-LATENCY-LT
- current, low, mean, high
(15 min/24 h records available
for PM values except current
value; user configurable
threshold crossing alerts for
latency too high / latency too
low)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
alerts for ES too high)
Severely errored seconds SES-OTU
(15 min/24 h records; user
configurable threshold crossing
alerts for SES too high)
Unavailable seconds UAS-OTU
(15 min/24 h records; user
configurable threshold crossing
alerts for UAS too high)
Background block errors BBE-OTU
(15 min/24 h records; user
configurable threshold crossing
alerts for BBE too high)
Table 675 provides information about protection setting for all variants.
5TCE-PCN-10GU+AES10G
The 5TCE-PCN-10GU+AES10G module is a 5-port 10G enterprise type TDM
channel module with five SFP/SFP+ interfaces on the client side and a single
SFP+ interface on the network side supporting data encryption. The module is
designed according to FIPS Publication 140-2 with security level 2, and can be
used for the transport of security-related data. The aggregated data stream is
encrypted/decrypted using the Advanced Encryption Standard (AES). Data
encryption and the use of an endpoint authentication mechanism protect the
network link between two communicating 5TCE-PCN-10GU+AES10G modules
against man-in-the-middle attacks.
The module can operate in following modes:
• TDM mode
o Transparent multiplexer mode:
The incoming data stream is mapped bit for bit in a simplified G.709
frame. The client ports support 1G FC, 2G FC, F2488 (STM16/OC-48),
4G FC, 5G IB, and 1GbE. The data rate on the network port depends on
the application. Transport of 5G IB services is supported in the TDM
mode multiplexing up to 2 x 5G IB. 5G IB transport requires the use of
the appropriate SFP+ devices in the client interfaces C1 and C2.
o Framed mode:
In framed mode the physical coding sublayer (PCS) is terminated. The
8B/10B coding is removed prior to multiplexing. Rate adaption is
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
performed through byte stuffing. The client ports support 1G FC, 2G FC,
4G FC, 8G FC and 1GbE. 8G FC can be applied at client port 1 only.
• Transparent transponder mode:
This mode is similar to the transparent multiplexer mode, but it allows to
transport 8G FC, F9953 (STM64/OC-192), 10G FC, and 10GbE LAN as
single service only applied at client port 1.
Table 677 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Type of network ports SFP+
Data rates 10.9747 Gbit/s for 8G FC,
(transparent transponder mode) 11.3176 Gbit/s for 10G FC
11.0957Gbit/s for 10 GbE,
10.709Gbit/s for F9953
Data rates 11.3176 Gbit/s
(multiplexer mode, transparent as well as
framed)
Protocols Subset G. 709 OTU2
1G FC = 2 VC
(starting at VC number 1 through 11 only)
2G FC, F2488 = 3 VC
(starting at VC number 1 through 10 only)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
4G FC = 5 VC
(starting at VC number 1 through 8 only)
5G IB = 6VC
(starting at VC number 1, 7 only)
Framed mode Support of 12 virtual containers (VC).
Number of concatenated VCs needed:
1G FC = 1 VC
(starting at every VC number possible)
2G FC or 1GbE = 2 VC
(starting at VC number 1, 3, 5, 7, 9, 11 only)
4G FC = 4 VC
(starting at VC number 1, 5, 9 only)
8G FC = 8 VC
(starting at VC number 1, 5 only)
Max. frame size for:
FC services < 2200 bytes
GbE services 9600 bytes
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
10.709 Gbit/s and 11.0957 Gbit/s;
For these data rates the module can interwork
with the 10TCC-PCTN-100G as OTU2
aggregator.
Table 685 provides information about the multiplexing and mapping schemes.
Table 686 provides information about fault monitoring on the module equipment
level in general.
Table 687 provides information about fault monitoring of the client interfaces.
Table 688 provides information about fault monitoring of the network interface.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
value; user configurable
threshold crossing alerts for
OPR too high / OPR too low)
Optical output power Tx - T-OPT-FHT
current, low, mean, high T-OPT-FLT
(15 min/24 h records available
for PM values except current
value; fix threshold crossing
alerts for OPT too high / OPT
too low)
SFP/SFP+ T-TEMP-FHT
current analogue value T-TEMP-FLT
(Fix threshold crossing alert for
CFP transceiver temperature
too high/too low available)
Laser bias current level (current LBCL
analogue value)
Latency - measured round trip T-LATENCY-HT
client-to-client T-LATENCY-LT
- current, low, mean, high
(15 min/24 h records available
for PM values except current
value; user configurable
threshold crossing alerts for
latency too high / latency too
low)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
OTU2 layer Errored seconds ES-OTU
(15 min/24 h records; user
configurable threshold
crossing alerts for ES too high)
Severely errored seconds SES-OTU
(15 min/24 h records; user
configurable threshold
crossing alerts for SES too
high)
Unavailable seconds UAS-OTU
(15 min/24 h records; user
configurable threshold
crossing alerts for UAS too
high)
Background block errors BBE-OTU
(15 min/24 h records; user
configurable threshold
crossing alerts for BBE too
high)
Table 694 provides information about protection setting for all variants.
4WCE-PCN-16GFC
The 4WCE-PCN-16GFC is an enterprise type, WDM quad transponder module.
It can have up to four client SFP+ type pluggable interfaces and four network
XFP type pluggable interfaces. The module converts up to four client side
signals to four specific ITU-T compliant network side wavelengths.
The 4WCE-PCN-16GFC contains four independent transponders especially
designed for the transport of 16 G FC services even though 8 G FC and 10 GbE
LAN PHY services are also supported on the client and network interfaces.
Table 696 contains general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
+40°C, 5% to 90% relative
humidity (non condensing)
Environmental conditions for Operating temperature: +5°C to
SH1HU-HP/2DC, SH1HU-R/PF, +40°C, 5% to 85% relative
SH1HU-HP/E-TEMP/2DC humidity (non condensing)
Short-term temperature: -5°C to
+45°C, 5% to 90% relative
humidity (non condensing)
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 365,630 h
Typ. power consumption (incl. 24 W
transceivers)
Max. power consumption (incl. 30 W
transceivers)
Slot positions SH9HU: slots 3...18,
SH7HU, SH7HU-R: slots 3...18
SH1HU: slots 1, 2
NCU types NCU-II, NCU-II-P
The following table provides a summary of the supported client SFPs. Please
refer to the specifications of the individual SFP+ type.
The following table provides a summary of the supported network XFPs. Please
refer to the specifications of the individual XFP type.
Table 700: Supported Network XFPs
DWDM types XFP/16GFC/#xxxxxL/SM/LC#Dxx
XFP/16GFC/#19xxxL50/SM/LC
XFP/11G/#19xxxL50/SM/LC
XFP/11G/DCTV/SM/LC
XFP/11G/Dxxxx.xxV/SM/LC#Dxx
CWDM types XFP/11G/CxxxxV/SM/LC
This table shows information about fault monitoring of the module in general.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Client port SFP+ temperature;
Network port XFP not approved;
Network port XFP missing;
Network port XFP voltage alarm;
Network port XFP temperature
This table shows information about fault monitoring of the client ports in general.
This table shows information about fault monitoring of the network ports in
general.
This table shows information about performance monitoring of the client ports in
general.
This table shows information about performance monitoring of the network ports
in general.
Pluggable Transceivers
This chapter describes pluggable transceivers of the FSP 3000R7.
The descriptions of the discontinued pluggable transceivers can be found in a
former version of the FSP 3000R7 Module and System Specification.
The following sections are provided:
“XFP/16GFC/#xxxxxL/SM/LC#Dxx” on p. 382
“XFP/16GFC/#19xxxL50/SM/LC” on p. 384
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
“XFP/11G/DCTV/SM/LC” on p. 386
“XFP/11G/DCTLNR/SM/LC” on p. 388
“XFP/11G/DCTLN/SM/LC” on p. 390
“XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev. 4.01)” on p. 392
“XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev. 5.01)” on p. 394
“XFP/11G/#19xxxL50/SM/LC” on p. 396
“XFP/OTN11G/#19xxxV/SM/LC” on p. 398
“XFP/8G/#xxxxxL/SM/LC#Dxx” on p. 400
“XFP/11G/CxxxxL/SM/LC” on p. 402
“XFP/11G/CxxxxV/SM/LC” on p. 404
“XFP/8G/CxxxxL/SM/LC” on p. 406
“XFP/10G/850I/MM/LC (HW Rev. 1.01)” on p. 408
“XFP/10G/850I/MM/LC (HW Rev. 2.01)” on p. 409
“XFP/11G/1310S/SM/LC” on p. 410
“XFP/11G/1550L/SM/LC” on p. 411
“XFP/8G/1310S/SM/LC” on p. 412
“XFP/8G/850I/MM/LC” on p. 413
“SFP+/16GFC/1310S/SM/LC” on p. 414
“SFP+/16GFC/850I/MM/LC” on p. 415
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
“SFP/4GU/CxxxxL/SM/LC” on p. 440
“SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx” on p. 442
“SFP/2G5U/CxxxxV/SM/LC” on p. 444
“SFP/2G5U/CxxxxL/SM/LC” on p. 446
“SFP/2G5U/1310S/SM/LC (HW Rev. 2.01)” on p. 447
“SFP/2G5U/1310L/SM/LC” on p. 448
“SFP/3GSDI/#xxxxxV/SM/LC” on p. 449
“SFP/3GSDI/ELECTRICAL/DIN” on p. 451
“SFP/3GSDI/ELECTRICAL/HBNC” on p. 452
“SFP/HS/1310S/SM/LC” on p. 453
“SFP/CL/1310I/SM/LC” on p. 454
“SFP/2G1/850I/MM/LC” on p. 455
“SFP/GBE/1310S/SM/LC/TIN” on p. 457
“SFP/GBE/1310L/SM/LC/TIN” on p. 458
“SFP/GBE/1550V/SM/LC/TIN” on p. 459
“SFP/GBE/850I/MM/LC/TIN” on p. 460
“SFP/GBE/B1310S/SM/LC” on p. 461
“SFP/GBE/B1490S/SM/LC” on p. 462
“SFP/GBE/B1310L/SM/LC” on p. 463
“SFP/GBE/B1490L/SM/LC” on p. 464
“SFP/GBE/Electrical/RJ45” on p. 465
“SFP/FE/C1490U/SM/LC” on p. 466
“SFP/FE/C1510U/SM/LC” on p. 467
“SFP/FE/C1490V/SM/LC” on p. 468
“SFP/FE/C1510V/SM/LC” on p. 469
“SFP/FE/D1528.77E/SM/LC” on p. 470
“SFP/FE/Dxxxx.xxV/SM/LC” on p. 471
“CFP/112G/LR10R/SM/LC” on p. 472
“CFP/112G/LR4/SM/LC” on p. 475
“CFP/103G/SR10/MM/MPO” on p. 478
“CFP/4x28G/#19xxx-#19xxxL/SM/LC” on p. 480
“CFP/4x28G/#DCTL/SM/LC” on p. 483
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
XFP/16GFC/#xxxxxL/SM/LC#Dxx
The XFP/16GFC/#xxxxxL/SM/LC#Dxx is an MSA-compliant pluggable trans-
ceiver for data rates of 4.25 Gbit/s, 8.5 Gbit/s and 14.025 Gbit/s. It is used for
bidirectional communication over single-mode fiber.
This transceiver is operating at DWDM wavelengths according to ITU-T G.694.1
and provides digital diagnostic monitoring of operating parameters such as opti-
cal input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 2,410,826 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 4.25 Gbit/s, 8.5 Gbit/s, 14.025 Gbit/s
Protocols 4G FC, 8G FC, 16G FC
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelength range 41 channels, 100 GHz spacing in
C band acc. to ITU-T G.694.1
Wavelength stability (operating) +/- 125 pm
Min. extinction ratio 8.2 dB
Min. sidemode suppression ratio 35 dB
Receiver wavelength range 1500 nm ... 1600 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -13 dBm ... -1 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -18 dBm ... 0 dBm
Optimum dispersion load range 0 ps/nm ... +400ps/nm
Dispersion load range with 2 dB -400 ps/nm... 0 ps/nm and
OSNR penalty in case of amplified +400 ps/nm ... +700 ps/nm
links or 2 dB receive power penalty
in case of unamplified links
OSNR penalty at 10 ps PMD for 1 dB (outage probability 4x10-5)
BER > 10-5
XFP/16GFC/#19xxxL50/SM/LC
The XFP/16GFC/#19xxxL50/SM/LC is an MSA-compliant pluggable transceiver
for data rates of 4.25 Gbit/s, 8.5 Gbit/s and 14.025 Gbit/s. It is used for bidirec-
tional communication over single-mode fiber.
This transceiver is operating at DWDM wavelengths according to ITU-T G.694.1
and provides digital diagnostic monitoring of operating parameters such as opti-
cal input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
office environments only.
MTBF at 25°C ambient temperature 2,410,826 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 4.25 Gbit/s, 8.5 Gbit/s, 14.025 Gbit/s
Protocols 4G FC, 8G FC, 16G FC
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelength range 96 channels, 50 GHz spacing in
C band acc. to ITU-T G.694.1
Wavelength stability (operating) 60 pm operating
Min. extinction ratio 8.2 dB
Min. sidemode suppression ratio 35 dB
Receiver wavelength range 1500 nm ... 1600 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -12 dBm ... 0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -14 dBm ... +3 dBm
Optimum dispersion load range -100 ps/nm ... +100 ps/nm
Dispersion load range with 1 dB -200 ps/nm... -100 ps/nm and
OSNR penalty +100 ps/nm ... +400 ps/nm
Dispersion load range with 2 dB -400 ps/nm... -200 ps/nm and
OSNR penalty +400 ps/nm ... +700 ps/nm
XFP/11G/DCTV/SM/LC
The XFP/11G/DCTV/SM/LC is a Multi-Protocol Optical XFP that provides a high
speed serial link at data rates from 9.95 Gbit/s to 11.35 Gbit/s. It is used for
bidirectional communication over single-mode fiber.
The transmitter is fully tunable to any of the C-band channels. Each channel can
be tuned in the system management by using the NE management tools.
It is intended for use in FSP 3000R7 modules with tunable XFP interface cages.
Proper functionality and valid certification of transponder modules can be
guaranteed with XFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 2,600,000 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s, 10.6642 Gbit/s,
10.709 Gbit/s, 11.0032 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s,
11.3176 Gbit/s
Protocols STM-64/OC-192, 10 G FC,
10 GbE LAN PHY,
10 GbE WAN PHY, OTU1e,
OTU2, OTU2e
Transmitter output power range -1 dBm ... +3 dBm
Transmitter wavelength range 81 channels, 50 GHz spacing in C
band acc. to ITU-T G.698.1
(tunable)
Wavelength stability (operating) +/- 60 pm
Min. extinction ratio 8 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1260 nm ... 1610 nm
Max. receiver reflectance 27 dB
Receiver dynamic range for OSNR -22 dBm ... -7 dBm
> 30 dB (0.1 nm)
XFP/11G/DCTLNR/SM/LC
The XFP/11G/DCTLNR/SM/LC is an Multi-Protocol Optical XFP that provides a
high speed serial link at data rates from 9.95 Gbit/s to 11.317 Gbit/s. It is used
for bidirectional communication over single-mode fiber. This tunable DWDM
XFP transceiver is an MSA-compliant pluggable transceiver, which complies
with the ITU-T G.698.1 SD100S1-2D for the C band in a wavelength grid of
50 GHz.
The transmitter is fully tunable to any of the C-band channels. Each channel can
be tuned in the system management by using the NE management tools.
The XFP/11G/DCTLNR/SM/LC offers a high extinction ratio and thus it is
suitable for links with a high amount of amplifiers and low OSNR. It features
reduced set of technical data in comparison to other FSP 3000R7 modules also
offering high extinction ratio.
This transceiver is intended for use in FSP 3000R7 modules with tunable XFP
interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with XFP types approved by ADVA Optical
Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Module type XFP
Weight 50 g (0.11 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 1,421,464 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s, 10.6642 Gbit/s,
10.709 Gbit/s, 11.0032 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s,
11.3176 Gbit/s
Protocols STM-64/OC-192, 10G FC,
10 GbE LAN PHY,
10 GbE WAN PHY, OTU1e, OTU2,
OTU2e
Transmitter output power range -1 dBm ... +3 dBm
Transmitter wavelength range 81 channels, 50 GHz spacing in C
band acc. to ITU-T G.698.1
(tunable)
Wavelength stability (operating) +/- 60 pm
XFP/11G/DCTLN/SM/LC
The XFP/11G/DCTLN/SM/LC is an Multi-Protocol Optical XFP that provides a
high speed serial link at data rates from 9.95 Gbit/s to 11.317 Gbit/s. It is used
for bidirectional communication over single-mode fiber. This tunable DWDM
XFP transceiver is an MSA-compliant pluggable transceiver, which complies
with the ITU-T G.698.1 SD100S1-2D for the C band in a wavelength grid of
50 GHz.
The transmitter is fully tunable to any of the C-band channels. Each channel can
be tuned in the system management by using the NE management tools.
The XFP/11G/DCTLN/SM/LC offers a high extinction ratio and thus it is suitable
for links with a high amount of amplifiers and low OSNR.
This transceiver is intended for use in FSP 3000R7 modules with tunable XFP
interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with XFP types approved by ADVA Optical
Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Environmental conditions Operating temperature: +5°C … +40°C
5% ... 85% relative humidity
(non-condensing)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s, 10.6642 Gbit/s,
10.709 Gbit/s, 11.0032 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s,
11.3176 Gbit/s
Protocols STM-64/OC-192, 10 GbE LAN PHY,
10 GbE WAN PHY, 10 G FC, OTU2,
OTU1e, OTU2e
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelength range 41 channels, 100 GHz spacing in C
band acc. to ITU-T G.694.1
Wavelength stability (operating) +/- 100 pm
Min. extinction ratio 8 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1260 nm ... 1610 nm
Max. receiver reflectance 27 dB
Receiver dynamic range at OSNR -23 dBm ... -7 dBm
> 30 dB
Receiver dynamic range at OSNR -20 dBm ... -7 dBm
< 30 dB
OPR/OPT accuracy +/- 3 dB
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s, 10.6642 Gbit/s,
10.709 Gbit/s, 11.0032 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s,
11.3176 Gbit/s
Protocols STM-64/OC-192, 10 GbE LAN PHY,
10 GbE WAN PHY, 10 G FC, OTU2,
OTU1e, OTU2e
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelength range 41 channels, 100 GHz spacing in C
band acc. to ITU-T G.694.1
Wavelength stability (operating) +/- 100 pm
Min. extinction ratio 8 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1260 nm ... 1610 nm
Max. receiver reflectance 27 dB
Receiver dynamic range at OSNR -23 dBm ... -7 dBm
> 30 dB
Receiver dynamic range at OSNR -20 dBm ... -7 dBm
< 30 dB
OPR/OPT accuracy +/- 3 dB
XFP/11G/#19xxxL50/SM/LC
The XFP/11G/#19xxxL50/SM/LC is an MSA-compliant pluggable transceiver
for 11 Gbit/s data rates and bidirectional communication over single-mode fiber.
It is operating at DWDM wavelengths according to ITU-T G.694.1 and it
provides digital diagnostic monitoring of operating parameters such as optical
input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s, 10.6642 Gbit/s,
10.709 Gbit/s, 11.0032 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s,
11.3176 Gbit/s
Protocols STM-64/OC-192, 10 GbE LAN PHY,
10 GbE WAN PHY, 10 G FC, OTU2,
OTU1e, OTU2e
Transmitter output power range -1 dBm ... +4 dBm
Transmitter wavelength range 96 channels, 50 GHz spacing in C
band acc. to ITU-T G.694.1
48 channels, 100 GHz spacing in C
band acc. to ITU-T G.694.1
Wavelength stability (operating) 12GHz
Min. extinction ratio 8.2 dB
Min. sidemode suppression ratio 35 dB
Receiver wavelength range 1270 nm ... 1600 nm
Max. receiver reflectance 26 dB
Receiver dynamic range -14 dBm ... 0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -18 dBm ... +2 dBm
Optimum dispersion load range -300 ps/nm ... +300 ps/nm
XFP/OTN11G/#19xxxV/SM/LC
The XFP/OTN11G/#19xxxV/SM/LC is an MSA-compliant pluggable transceiver
for 11 Gbit/s data rates and bidirectional communication over single-mode fiber.
It is operating at DWDM wavelengths according to ITU-T G.694.1 and it
provides digital diagnostic monitoring of operating parameters such as optical
input power, temperature or laser bias. This transceiver supports OTU2e
services according to ITU-T G.709 to enable GFEC.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
temperature
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 11.0957 Gbit/s
Protocols OTU2e (OTU2LAN with stuffing)
Transmitter output power 0 dBm ... +3 dBm
range
Transmitter wavelength range 41 channels, 100 GHz spacing in
C band acc. to ITU-T G.694.1
Wavelength stability +/- 100 pm
(operating)
Min. extinction ratio 9 dB
Min. sidemode suppression 30 dB
ratio
Receiver wavelength range 1527 nm ... 1567 nm
Max. receiver reflectance 27 dB
Receiver dynamic range at -25 dBm ... -7 dBm over the entire
OSNR > 33 dB dispersion load range
Receiver dynamic range at -18 dBm ... -7 dBm
OSNR > 16 dB
OPR/OPT accuracy +/- 3 dB
OPR measurement range -28 dBm ... -4 dBm
Min. dispersion load -700 ps/nm
XFP/8G/#xxxxxL/SM/LC#Dxx
The XFP/8G/#xxxxxL/SM/LC#Dxx is an MSA-compliant pluggable transceiver
for 4.25 Gbit/s and 8.5 Gbit/s data rates and bidirectional communication over
single-mode fiber. It is operating at DWDM wavelengths according to ITU-T
G.694.1 and provides digital diagnostic monitoring of operating parameters
such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 4.25 Gbit/s, 8.5 Gbit/s
Protocols 4G FC, 8G FC
Transmitter output power range -0.5 dBm ... +4 dBm
Transmitter wavelength range 41 channels, 100 GHz spacing in
C band acc. to ITU-T G.694.1
Wavelength stability (operating) +/- 100 pm
Min. extinction ratio 8 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1270 nm ... 1600 nm
Max. receiver reflectance 27 dB
Receiver dynamic range at OSNR -22 dBm ... -7 dBm
> 30 dB
Receiver dynamic range at OSNR -20 dBm ... -7 dBm
> 25 dB
OPR/OPT accuracy +/- 3 dB
OPR measurement range -22 dBm ... -4 dBm
Optimum dispersion load range +300 ps/nm ... +600 ps/nm
Dispersion load range with 1 dB 0 ps/nm ... +300 ps/nm and
OSNR penalty +600 ps/nm ... +900 ps/nm
XFP/11G/CxxxxL/SM/LC
The XFP/11G/CxxxxL/SM/LC is an MSA-compliant pluggable transceiver for
11 Gbit/s data rates and bidirectional communication over single-mode fiber. It
is operating at CWDM wavelengths according to ITU-T G.694.2 and it provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s, 10.51875
Gbit/s, 10.6642 Gbit/s, 10.709 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s
Protocols STM-64/OC-192, 10 GbE LAN PHY,
10 GbE WAN PHY, 10G FC, OTU2,
OTU1e, OTU2e
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelength range 1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm, 1611 nm
Min. extinction ratio 8 dB
Min. sidemode suppression ratio 35 dB
Receiver wavelength range 1260 nm ... 1610 nm
Max. receiver reflectance 27 dB
Receiver dynamic range without -16 dBm ... -9 dBm
FEC
OPR/OPT accuracy +/- 3 dB
OPR measurement range -16 dBm ... -6 dBm
XFP/11G/CxxxxV/SM/LC
The XFP/11G/CxxxxV/SM/LC is an MSA-compliant pluggable transceiver for
11 Gbit/s data rates and bidirectional communication over single-mode fiber. It
is operating at CWDM wavelengths according to ITU-T G.694 and it provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s, 10.51875
Gbit/s, 10.6642 Gbit/s, 10.709 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s
Protocols STM-64/OC-192, 10 GbE LAN PHY,
10 GbE WAN PHY, 10 G FC, OTU2,
OTU1e, OTU2e
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelength range 1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm, 1611 nm
Min. extinction ratio 8 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1260 nm ... 1610 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -22 dBm ... -9 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -22 dBm ... -6 dBm
XFP/8G/CxxxxL/SM/LC
The XFP/8G/CxxxxL/SM/LC is an MSA-compliant pluggable transceiver for
4.25 Gbit/s and 8.5 Gbit/s data rates and bidirectional communication over
single-mode fiber. It is operating at CWDM wavelengths according to ITU-T
G.694.2 and it provides digital diagnostic monitoring of operating parameters
such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with XFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 4.25 Gbit/s, 8.5 Gbit/s
Protocols 4G FC, 8G FC
Transmitter output power range -1 dBm ... +4 dBm
Transmitter wavelength range 1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm, 1611 nm
Min. extinction ratio 8.2 dB
Min. sidemode suppression ratio 35 dB
Receiver wavelength range 1260 nm ... 1610 nm
Max. receiver reflectance 12 dB
Receiver dynamic range without -16 dBm ... -1 dBm
FEC
OPR/OPT accuracy +/- 3 dB
OPR measurement range -18 dBm ... +1 dBm
Min. dispersion load -260 ps/nm for XFP/8G/C1470L/SM/LC
-280 ps/nm for XFP/8G/C1490L/SM/LC
-300 ps/nm for XFP/8G/C1510L/SM/LC
-320 ps/nm for XFP/8G/C1530L/SM/LC
-340 ps/nm for XFP/8G/C1550L/SM/LC
-360 ps/nm for XFP/8G/C1570L/SM/LC
-380 ps/nm for XFP/8G/C1590L/SM/LC
-400 ps/nm for XFP/8G/C1610L/SM/LC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmitter fiber type MM 62.5 µm
Receiver fiber type MM 62.5 µm
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s
Protocols 10 GbE LAN PHY, 10 GbE WAN PHY,
10G FC
Transmitter output power range -8 dBm ... -1 dBm
Transmitter wavelength range 840 nm ... 860 nm
Min. extinction ratio 3 dB
Receiver wavelength range 840 nm ... 860 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -9.9 dBm ... -1 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -11 dBm ... 2 dBm
Max. link distance multimode fiber
at data rate 9.9532 to 10.3125 Gbit/s
50/125 µm MMF 400 2 m - 66 m
50/125 µm MMF 500 2 m - 82 m
50/125 µm MM fiber OM3 2 m - 300 m
XFP/11G/1310S/SM/LC
The XFP/11G/1310S/SM/LC is an MSA-compliant pluggable transceiver for
10 Gbit/s and 11 Gbit/s data rates and bidirectional communication over
single-mode fiber. It is operating at a wavelength of 1310 nm and it provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. It is intended for use in FSP 3000R7 modules
with XFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with XFP types approved by ADVA
Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s, 10.6642 Gbit/s,
10.709 Gbit/s, 11.0491 Gbit/s,
11.0957 Gbit/s, 11.317 Gbit/s
Protocols STM-64/OC-192, 10 GbE LAN PHY,
10 GbE WAN PHY, 10G FC, OTU2,
OTU2e
Transmitter output power range -6 dBm ... -1 dBm
Transmitter wavelength range 1290 nm ... 1330 nm
Min. extinction ratio 6 dB
Nominal receiver wavelength range 1260 nm ... 1360 nm
Receiver dynamic range -13 dBm ... -1 dBm
at 1260 nm ... 1360 nm
Receiver dynamic range -11 dBm ... -1 dBm
at 1530 nm ... 1565 nm
Max. receiver reflectance 14 dB
OPR/OPT accuracy +/- 3 dB
OPR measurement range -13 dBm ... 2 dBm
Max. link distance 10 km
with SMF-28 single-mode fiber
Max. power penalty at dispersion 2 dB
(depending on link distance)
Bit error ratio < 10-12
Max. module delay < 3 ns
XFP/11G/1550L/SM/LC
The XFP/11G/1550L/SM/LC is an MSA-compliant pluggable transceiver for
10 Gbit/s data rates and bidirectional communication over single-mode fiber. It
is operating at a wavelength of 1550 nm and it provides digital diagnostic
monitoring of operating parameters such as optical input power, temperature or
laser bias. It is intended for use in FSP 3000R7 modules with XFP interface
cages. Proper functionality and valid certification of transponder modules can
be guaranteed with XFP types approved by ADVA Optical Networking only.
XFP/8G/1310S/SM/LC
The XFP/8G/1310S/SM/LC is an MSA-compliant pluggable transceiver for data
rates of 4.25 Gbit/s and 8.5 Gbit/s and bidirectional communication over
single-mode fiber. It is operating at a wavelength of 1310 nm and it provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. It is intended for use in FSP 3000R7 modules
with XFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with XFP types approved by ADVA
Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmitter fiber type SM
Receiver fiber type SM
Data rates 4.25 Gbit/s, 8.5 Gbit/s
Protocols 4G FC, 8G FC
Transmitter output power range -6 dBm ... -1 dBm
Transmitter wavelength range 1290 nm ... 1330 nm
Min. extinction ratio 4 dB
Nominal receiver wavelength range 1260 nm ... 1360 nm
Receiver dynamic range -10 dBm ... 0.5 dBm
at 1260 nm ... 1360 nm
Receiver dynamic range -8 dBm ... 0.5 dBm
at 1530 nm ... 1565 nm
Max. receiver reflectance 14 dB
OPR/OPT accuracy +/- 3 dB
OPR measurement range -10 dBm ... 3.5 dBm
Max. link distance 10 km
with SMF-28 single-mode fiber
Bit error ratio < 10-12
Max. module delay < 3 ns
XFP/8G/850I/MM/LC
The XFP/8G/850I/MM/LC is an MSA-compliant pluggable transceiver for data
rates of 4.25 Gbit/s and 8.5 Gbit/s and bidirectional communication over
multimode fiber. It is operating at a wavelength of 850 nm and it provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias. It is intended for use in FSP 3000R7 modules with
XFP interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with XFP types approved by ADVA Optical
Networking only.
SFP+/16GFC/1310S/SM/LC
The SFP+/16GFC/1310S/SM/LC is an MSA-compliant pluggable transceiver for
4.25 Gbit/s, 8.5 Gbit/s and 14.025 Gbit/s data rates and bidirectional
communication over single-mode fiber. It is operating at a wavelength of
1310 nm and it provides digital diagnostic monitoring of operating parameters
such as optical input power, temperature or laser bias. It is intended for use in
FSP 3000R7 modules with SFP+ interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP+ types
approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmitter fiber type 9/125 µm SM
Receiver fiber type 9/125 µm SM
Data rates 4.25 Gbit/s, 8.5 Gbit/s,
14.025 Gbit/s
Transmitter output power range -5 dBm ... +2 dBm
Transmitter wavelength range 1295 nm ... 1325 nm
Min. extinction ratio 3.5 dB
Receiver wavelength range 1260 nm ... 1610 nm
Max. average receiver power 2 dBm
Receiver dynamic range -12 dBm ... +2 dBm
Max. receiver reflectance 12 dB
Max. link distance 10 km
OPR/OPT accuracy +/- 3 dB
OPR measurement range -15 dBm ... +5 dBm
Bit error ratio <10-12
Max. module delay < 3 ns
SFP+/16GFC/850I/MM/LC
The SFP+/16GFC/850I/MM/LC is an MSA-compliant pluggable transceiver for
4.25 Gbit/s, 8.5 Gbit/s and 14.025 Gbit/s data rates and bidirectional
communication over multimode fiber. It is operating at a wavelength of 850 nm
and it provides digital diagnostic monitoring of operating parameters such as
optical input power, temperature or laser bias. It is intended for use in FSP
3000R7 modules with SFP+ interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP+ types
approved by ADVA Optical Networking only.
SFP+CDR/10GU/1550L/SM/LC
The SFP+CDR/10GU/1550L/SM/LC is an MSA-compliant pluggable transceiver
for 8.5 Gbit/s, 9.9533 Gbit/s, 10.0 Gbit/s and 10.3125 Gbit/s data rates. It is
used for bidirectional communication over single-mode fiber. This transceiver
supports clock and data recovery.
The SFP+CDR/10GU/1550L/SM/LC is operating at a wavelength of 1550 nm
and provides digital diagnostic monitoring of operating parameters such as opti-
cal input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages.
Proper functionality and valid certification of transponder modules can be guar-
anteed with SFP+ types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
IEC 60529 2 environment and indoor
controlled office environments
only.
MTBF at 25°C ambient temperature 6,711,409 h
Optical connector type Duplex LC
Transmitter fiber type SM 9/125 µm
Receiver fiber type SM 9/125 µm
Data rates 8.5 Gbit/s, 9.9533 Gbit/s,
10.0 Gbit/s, 10.3125 Gbit/s
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelength range 1530 nm ... 1565 nm
Min. extinction ratio 3 dB
Receiver wavelength range 1530 nm ... 1565 nm
Receiver dynamic range -16 dBm ... -1 dBm
Max. receiver reflectance 27 dB
OPR/OPT accuracy +/- 3 dB
OPR measurement range -18 dBm ... +1 dBm
Max. power penalty at dispersion 3 dB
Bit error ratio <10-12
Max. module delay 5 ns
SFP+CDR/10GU/850I/MM/LC
The SFP+CDR/10GU/850I/MM/LC is an MSA-compliant pluggable transceiver
for 8.5 Gbit/s and 10.3125 Gbit/s data rates and bidirectional communication
over multimode fiber. This transceiver supports clock and data recovery.
The SFP+CDR/10GU/850I/MM/LC is operating at a wavelength of 850 nm and
provides digital diagnostic monitoring of operating parameters such as optical
input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages.
Proper functionality and valid certification of transponder modules can be guar-
anteed with SFP+ types approved by ADVA Optical Networking only.
SFP+CDR/11GU/1310S/SM/LC
The SFP+CDR/11GU/1310S/SM/LC is an MSA-compliant pluggable trans-
ceiver for 8.5 Gbit/s, 9.9533 Gbit/s, 10 Gbit/s, 10.3125 Gbit/s, 10.518 Gbit/s,
10.709 Gbit/s, 11.0491 Gbit/s, 11.0957 Gbit/s and 11.3176 Gbit/s data rates. It
is used for bidirectional communication over single-mode fiber. This transceiver
supports clock and data recovery.
The SFP+CDR/11GU/1310S/SM/LC is operating at a wavelength of 1310 nm
and provides digital diagnostic monitoring of operating parameters such as opti-
cal input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages.
Proper functionality and valid certification of transponder modules can be guar-
anteed with SFP+ types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Degree of protection according to IP20. Use in a pollution degree
IEC 60529 2 environment and indoor
controlled office environments
only.
MTBF at 25°C ambient temperature 3,060,000 h
Optical connector type Duplex LC
Transmitter fiber type SM 9/125 µm
Receiver fiber type SM 9/125 µm
Data rates 8.5 Gbit/s, 9.9533 Gbit/s,
10 Gbit/s, 10.3125 Gbit/s,
10.518 Gbit/s, 10.709 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s,
11.3176 Gbit/s
Transmitter output power range -6 dBm ... -1 dBm
Transmitter wavelength range 1260 nm ... 1355 nm
Min. extinction ratio 6 dB
Receiver wavelength range 1260 nm ... 1600 nm
Max. average receiver power 0.5 dBm
Receiver dynamic range -11 dBm ... +0.5 dBm
Max. receiver reflectance 14 dB
OPR/OPT accuracy +/- 3 dB
OPR measurement range -14 dBm ... +2 dBm
SFP+CDR/11GU/CxxxxL/SM/LC
The SFP+CDR/11GU/CxxxxL/SM/LC is an MSA-compliant pluggable
transceiver for 11 Gbit/s data rates and bidirectional communication over
single-mode fiber. This transceiver supports clock and data recovery.
The SFP+CDR/11GU/CxxxxL/SM/LC is operating at eight CWDM wavelengths
with long reach according to ITU-T G.694.2. It provides digital diagnostic
monitoring of operating parameters such as optical input power, temperature or
laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages.
Proper functionality and valid certification of transponder modules can be
guaranteed with SFP+ types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
IEC 60529 environment and indoor controlled office
environments only.
MTBF at 25°C ambient 6,711,409 h
temperature
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 8.5 Gbit/s, 9.9532 Gbit/s, 10.0 Gbit/s,
10.3125 Gbit/s, 10.518 Gbit/s,
10.709 Gbit/s, 11.0491 Gbit/s,
11.0957 Gbit/s, 11.3176 Gbit/s
Protocols 8G FC, STM-64/OC-192, 10 GbE WAN
PHY, 10G IB, 10G FC, OTU2, OTU1e,
OTU2e, OTU2f
Transmitter output power range -4.7 dBm ... +4 dBm
Transmitter wavelength range 1471 nm, 1491 nm, 1511 nm, 1531 nm
1551 nm, 1571 nm, 1591 nm, 1611 nm
Center wavelength stability +/- 6.5 nm
Min. extinction ratio 3.0 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1450 nm ... 1620 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -16.0 dBm ... -1.0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -19 dBm to +1 dBm
SFP+CDR/11GU/CxxxxS/SM/LC
The SFP+CDR/11GU/CxxxxS/SM/LC is an MSA-compliant pluggable
transceiver for 11 Gbit/s data rates and bidirectional communication over
single-mode fiber. This transceiver supports clock and data recovery.
The SFP+CDR/11GU/CxxxxS/SM/LC operates at four CWDM wavelengths with
standard reach according to ITU-T G.694.2. It provides digital diagnostic
monitoring of operating parameters such as optical input power, temperature or
laser bias. This SFP+ transceiver is intended to be used to connect to
40GBASE-LR4 using J/SM/4CS-#C1270-#C1330/LC breakout cable.
The SFP+CDR/11GU/CxxxxS/SM/LC is intended for use in FSP 3000R7
modules with SFP+ interface cages. Proper functionality and valid certification
of transponder modules can be guaranteed with SFP+ types approved by ADVA
Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled office
environments only.
MTBF at 25°C ambient 2,518,892 h
temperature
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 9.9532 Gbit/s, 10.0 Gbit/s, 10.3125
Gbit/s, 10.5187 Gbit/s, 10.709 Gbit/s,
10.754 Gbit/s, 11.0491 Gbit/s, 11.0957
Gbit/s, 11.3176 Gbit/s
Protocols STM-64/OC-192, 10 GbE WAN PHY,
10G IB, 10 GbE LAN PHY, 10G FC,
OTU2, OTU2V, OTU1e, OTU2e, OTU2f
Transmitter output power range -5 dBm ... 0 dBm
Transmitter wavelength range 1271 nm, 1291 nm, 1311 nm, 1331 nm
Center wavelength stability +/- 6.5 nm
Min. extinction ratio 3.5 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1250 nm ... 1350 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -13.0 dBm ... 0 dBm
OPR/OPT accuracy +/- 3 dB
SFP+/10G/1310S/SM/LC
The SFP+/10G/1310S/SM/LC is an MSA-compliant pluggable transceiver
supporting up to 10 Gbit/s data rates and bidirectional communication over
single-mode fiber. It is operating at a wavelength of 1310 nm and it provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. It is intended for use in FSP 3000R7 modules
with SFP+ interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP+ types approved by ADVA
Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmitter fiber type 9/125 µm SM
Receiver fiber type 9/125 µm SM
Data rates 5 Gbit/s, 8.5 Gbit/s, 9.953 Gbit/s,
10 Gbit/s, 10.3125 Gbit/s,
10.51875 Gbit/s
Transmitter output power range -8 dBm ... -0.5 dBm
Transmitter wavelength range 1260 nm ... 1355 nm
Min. extinction ratio 3.5 dB
Receiver wavelength range 1260 nm ... 1355 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -14 dBm ... 0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -17 dBm ... 3 dBm
Max. power penalty at dispersion 3.2 dB
Max. link distance 10 km
Bit error ratio < 10-12
Max. module delay 3 ns
SFP+/10G/850I/MM/LC
The SFP+/10G/850I/MM/LC is an MSA-compliant pluggable transceiver
supporting up to 10 Gbit/s data rates and bidirectional communication over
multimode fiber. It is operating at a wavelength of 850 nm and it provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias. It is intended for use in FSP 3000R7 modules with
SFP+ interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with SFP+ types approved by ADVA Optical
Networking only.
SFP+/11GU/#19xxxL50/SM/LC
The SFP+/11GU/#19xxxL50/SM/LC is an MSA-compliant pluggable transceiver
for 11 Gbit/s data rates and bidirectional communication over single-mode fiber.
It operates at 50GHz DWDM wavelengths according to ITU-T G.694.1 and it
provides digital diagnostic monitoring of operating parameters such as optical
input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages.
Proper functionality and valid certification of transponder modules can be
guaranteed with SFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 4,329,004 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 8.5 Gbit/s, 9.9532 Gbit/s, 10.0 Gbit/s,
10.3125 Gbit/s, 10.518 Gbit/s,
10.709 Gbit/s, 10.7595 Gbit/s
10.9747 Gbit/s, 11.0491 Gbit/s,
11.0957 Gbit/s, 11.3176 Gbit/s
Protocols 8G FC, STM-64/OC-192,
10 GbE WAN PHY, 10G IB,
10 GbE LAN PHY, 10G FC, OTU2,
10G IB, OTU2V, OTU1e, OTU2e,
OTU2f
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelength range 96 channels, 50 GHz spacing in C
band acc. to ITU-T G.694.1
41 channels, 100 GHz spacing in C
band acc. to ITU-T G.694.1
Wavelength stability (operating) +/- 25 pm
Min. extinction ratio 8 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1270 nm ... 1600 nm
Max. receiver reflectance 27 dB
SFP+/11GU/CxxxxL/SM/LC
The SFP+/11GU/CxxxxL/SM/LC is an MSA-compliant pluggable transceiver for
11 Gbit/s data rates and bidirectional communication over single-mode fiber. It
is operating at CWDM wavelengths according to ITU-T G.694.2 and it provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages.
Proper functionality and valid certification of transponder modules can be
guaranteed with SFP+ types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 8.5 Gbit/s, 9.9532 Gbit/s, 10.0 Gbit/s,
10.3125 Gbit/s, 10.5187 Gbit/s,
10.709 Gbit/s, 10.754 Gbit/s,
10.7595 Gbit/s, 10.9747 Gbit/s,
11.0491 Gbit/s, 11.0957 Gbit/s,
11.3176 Gbit/s
Protocols 8G FC, STM-64/OC-192, 10G IB,
10 GbE, 10G FC, OTU2, OTU2V ,
OTU1e, OTU2e
Transmitter output power range -4 dBm ... +4 dBm
Transmitter wavelength range 1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm, 1611 nm
Min. extinction ratio 4.5 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1450 nm ... 1620 nm
Max. receiver reflectance 26 dB
Receiver dynamic range -16.0 dBm ... -1.0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -18 dBm ... +2 dBm
Max. power penalty at dispersion 3 dB at max. dispersion load
(regarding receiver sensitivity) 3 dB at min. dispersion load
SFP+/11GU/1310S/SM/LC
The SFP+/11GU/1310S/SM/LC is an MSA-compliant pluggable transceiver
supporting up to 11 Gbit/s data rates and bidirectional communication over
single-mode fiber. It is operating at a wavelength of 1310 nm and it provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. It is intended for use in FSP 3000R7 modules
with SFP+ interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP+ types approved by ADVA
Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmitter fiber type 9/125 µm SM
Receiver fiber type 9/125 µm SM
Data rates 5.0 Gbit/s1, 8.5 Gbit/s, 9.9533 Gbit/s,
10.0 Gbit/s, 10.3125 Gbit/s, 10.51875
Gbit/s, 10.709 Gbit/s, 10.7595 Gbit/s,
10.9747 Gbit/s, 11.0491 Gbit/s,
11.0957 Gbit/s, 11.3176 Gbit/s
Protocols 5G IB, 8G FC, STM-64/OC-192,
10G IB, 10 GbE, 10G FC, OTU2,
OTU2V, OTU1e, OTU2e
Transmitter output power range -8 dBm ... -1.0 dBm
Transmitter wavelength range 1290 nm ... 1330 nm
Min. extinction ratio 6.0 dB
Receiver wavelength range 1260 nm ... 1360 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -13.0 dBm ... -1.0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -13 dBm ... 2 dBm
Max. power penalty at dispersion 3.2 dB
Max. link distance 10 km
Bit error ratio < 10-12
Max. module delay 3 ns
1. 5.0 Gbit/s = 5G IB for HW rev. 2.01 or newer
SFP+/11GU/850I/MM/LC
The SFP+/11GU/850I/MM/LC is an MSA-compliant pluggable transceiver
supporting up to 11 Gbit/s data rates and bidirectional communication over
multimode fiber. It is operating at a wavelength of 850 nm and it provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias. It is intended for use in FSP 3000R7 modules with
SFP+ interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with SFP+ types approved by ADVA Optical
Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFP+/8GU/1310S/SM/LC
The SFP+/8GU/1310S/SM/LC is an MSA-compliant pluggable transceiver for
data rates of 2.125 Gbit/s, 4.25 Gbit/s and 8.5 Gbit/s and bidirectional
communication over single-mode fiber. It is operating at a wavelength of
1310 nm and it provides digital diagnostic monitoring of operating parameters
such as optical input power, temperature or laser bias. It is intended for use in
FSP 3000R7 modules with SFP+ interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP+ types
approved by ADVA Optical Networking only.
SFP+/8GU/850I/MM/LC
The SFP+/8GU/850I/MM/LC is an MSA-compliant pluggable transceiver for
data rates of 2.125 Gbit/s, 4.25 Gbit/s and 8.5 Gbit/s and bidirectional
communication over multimode fiber. It is operating at a wavelength of 850 nm
and it provides digital diagnostic monitoring of operating parameters such as
optical input power, temperature or laser bias. It is intended for use in FSP
3000R7 modules with SFP+ interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP+ types
approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmitter fiber type MM 62.5 µm
Receiver fiber type MM 62.5 µm
MM 50 µm
Data rates 2.125 Gbit/s, 4.250 Gbit/s, 8.5 Gbit/s
Transmitter output power range -9 dBm ... -2 dBm
Transmitter wavelength range 830 nm ... 860 nm
Min. extinction ratio 4 dB
Receiver wavelength range 840 nm ... 860 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -10 dBm ... 1 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -13 dBm ... 4 dBm
Max. power penalty at dispersion 4.2 dB
Max. link distance, 50 μm MM fiber dependent on customer interface
for standard fiber:
300 m at 2.125 Gbit/s
150 m at 4.250 Gbit/s
50 m at 8.5 Gbit/s
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx
The SFP/4GU/Dxxxx.xxV/SM/LC#Dxx is an MSA-compliant pluggable
transceiver for bidirectional communication over single-mode fiber. It is
operating at DWDM wavelengths according to ITU-T G.694.1. It provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias. It is intended for use in FSP 3000R7 modules with
SFP interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with SFP types approved by ADVA Optical
Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Receiver fiber type SM
Data rates 1.0625 Gbit/s, 2.125 Gbit/s,
4.250 Gbit/s
Transmitter output power range +2 dBm ... +5 dBm
Transmitter wavelengths depending 1471 nm, 1491 nm, 1511 nm, 1531 nm,
on respective SFP type 1551 nm, 1571 nm, 1591 nm, 1611 nm
according to ITU-T G.694.2
Min. extinction ratio 5 dB
Min. side mode suppression ratio 30 dB
Receiver wavelength range 1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm, 1611 nm
according to ITU-T G.694.2
Max. receiver reflectance 27 dB
Receiver dynamic range -23 dBm ... -9 dBm
(including dispersion penalties)
OPR/OPT accuracy +/- 3 dB
OPR measurement range -23 dBm ... -6 dBm
Min. dispersion load 0 ps/nm
Max. dispersion load 1400 ps/nm
Max. power penalty at dispersion 0 dB
Bit error ratio < 10-12
SFP/4GU/1310S/SM/LC
The SFP/4GU/1310S/SM/LC is an MSA-compliant pluggable 1310 nm
transceiver for bidirectional communication over single-mode fiber. It provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. It is intended for use in FSP 3000R7 modules
with SFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA
Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Receiver fiber type SM
Data rates 1.0625 Gbit/s, 2.125 Gbit/s, 4.250 Gbit/s
(1 Gbit/s Coupling Link is not supported)
Transmitter output power range -9 dBm ... -1 dBm
Transmitter wavelength range 1260 nm ... 1360 nm
Min. extinction ratio 3 dB
Receiver wavelength range 1260 nm ... 1360 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -18 dBm ... -1 dBm at 1.0625 Gbit/s,
2.125 Gbit/s
-15 dBm ... -1 dBm at 4.25 Gbit/s
OPR/OPT accuracy +/- 3 dB
OPR measurement range -18 dBm ... 2 dBm
Max. link distance 10 km at 1.0625 Gbit/s
10 km at 2.125 Gbit/s
4 km at 4.250 Gbit/s
Bit error ratio < 10-12
SFP/4GU/850I/MM/LC
The SFP/4GU/850I/MM/LC is an MSA-compliant pluggable 850 nm transceiver
for bidirectional communication over multimode fiber. It provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias. It is intended for use in FSP 3000R7 modules with
SFP interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with SFP types approved by ADVA Optical
Networking only.
SFP/4GU/CxxxxL/SM/LC
The SFP/4GU/CxxxxL/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at CWDM
wavelengths according to ITU-T G.694.2. It provides digital diagnostic
monitoring of operating parameters such as optical input power, temperature or
laser bias. It is intended for use in FSP 3000R7 modules with SFP interface
cages. Proper functionality and valid certification of transponder modules can
be guaranteed with SFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
1471 nm - 1611 nm 39,525,692 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 1.0625 Gbit/s, 2.125 Gbit/s, 4.250 Gbit/s
Transmitter output power range +1 dBm ... +5 dBm
Transmitter wavelengths 1471 nm, 1491 nm, 1511 nm, 1531 nm,
depending on respective SFP type 1551 nm, 1571 nm, 1591 nm, 1611 nm
according to ITU-T G.694.2
Min. extinction ratio 4 dB
Min. side mode suppression ratio 30 dB
Receiver wavelength range 1271 nm, 1291 nm, 1311 nm, 1331 nm,
1351 nm, 1371 nm, 1431 nm, 1451 nm,
1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm, 1611 nm
according to ITU-T G.694.2
Max. receiver reflectance 12 dB
Receiver dynamic range -16 dBm ... -6 dBm (1271 ... 1451 nm)
-16 dBm ... 0 dBm (1471 ... 1611 nm)
OPR/OPT accuracy +/- 3 dB
OPR measurement range -16 dBm ... -3 dBm (1271 ... 1451 nm)
-16 dBm ... 3 dBm (1471 ... 1611 nm)
Min. dispersion load 0 ps/nm
Max. dispersion load at 1611 nm 600 ps/nm
SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx
The SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx is an MSA-compliant pluggable
transceiver for bidirectional communication over single-mode fiber. It is
operating at DWDM wavelengths according to ITU-T G.694.1. It provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias. It is intended for use in FSP 3000R7 modules with
SFP interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with SFP types approved by ADVA Optical
Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 155 Mbit/s ... 2.67 Gbit/s up to HW Rev.
2.01 (1 Gbit/s Coupling Link is not
supported)
SFP/2G5U/CxxxxV/SM/LC
The SFP/2G5U/CxxxxV/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at CWDM
wavelengths according to ITU-T G.694.2. It provides digital diagnostic
monitoring of operating parameters such as optical input power, temperature or
laser bias. It is intended for use in FSP 3000R7 modules with SFP interface
cages. Proper functionality and valid certification of transponder modules can
be guaranteed with SFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rates 100 Mbit/s ... 2.67 Gbit/s
Transmitter output power range 0 dBm ... +5 dBm
Transmitter wavelengths 1471 nm, 1491 nm, 1511 nm, 1531 nm,
depending on respective SFP 1551 nm, 1571 nm, 1591 nm, 1611 nm
type according to ITU-T G.694.2
Min. extinction ratio 8.2 dB
Min. side mode suppression ratio 30 dB
Receiver wavelength range 1271 nm, 1291 nm, 1311 nm, 1331 nm,
1351 nm, 1371 nm, 1431 nm, 1451 nm,
1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm, 1611 nm
according to ITU-T G.694.2
Max. receiver reflectance 27 dB
Receiver dynamic range -28 dBm ... -9 dBm
Receiver dynamic range for data -30 dBm ... -9 dBm
rates up to 1.25Gbit/s
OPR/OPT accuracy +/- 3 dB
OPR measurement range -33 dBm ... -6 dBm
Min. dispersion load -1250 ps/nm at 2.67 Gbit/s
(1471 nm ... 1611 nm)
SFP/2G5U/CxxxxL/SM/LC
The SFP/2G5U/CxxxxL/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at CWDM
wavelengths according to ITU-T G.694.2. It provides digital diagnostic
monitoring of operating parameters such as optical input power, temperature or
laser bias. It is intended for use in FSP 3000R7 modules with SFP interface
cages. Proper functionality and valid certification of transponder modules can
be guaranteed with SFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmitter fiber type SM
Receiver fiber type SM
Data rates 100 Mbit/s ... 2.67 Gbit/s
Transmitter output power range 0 dBm ... +5 dBm
Transmitter wavelengths 1471 nm, 1491 nm, 1511 nm, 1531 nm,
depending on respective SFP type 1551 nm, 1571 nm, 1591 nm, 1611 nm
(according to ITU-T G.694.2)
Min. extinction ratio 8.2 dB
Min. side mode suppression ratio 30 dB
Receiver wavelength range 1471 nm, 1491 nm, 1511 nm, 1531 nm,
(according to ITU-T G.694.2) 1551 nm, 1571 nm, 1591 nm, 1611 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -20 dBm ... 0 dBm
Receiver dynamic range at GbE -23 dBm ... 0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -20 dBm ... 3 dBm
Min. dispersion load -1250 ps/nm
Max. dispersion load 1250 ps/nm
Max. power penalty at dispersion 2 dB at 1250 ps/nm
2 dB at -1250 ps/nm
Bit error ratio < 10-12
SFP/2G5U/1310L/SM/LC
The SFP/2G5U/1310L/SM/LC is an MSA-compliant pluggable 1310 nm
transceiver for bidirectional communication over single-mode fiber. It provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. It is intended for use in FSP 3000R7 modules
with SFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA
Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Receiver fiber type SM
Data rates 100 Mbit/s ... 2.67 Gbit/s (1 Gbit/s
Coupling Link is not supported)
Transmitter output power range -2 dBm ... +3 dBm
Transmitter wavelength range 1260 nm ... 1360 nm
Min. extinction ratio 8.2 dB
Receiver wavelength range 1260 nm ... 1580 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -27 dBm ... -9 dBm
Receiver dynamic range at GbE -30 dBm ... -9 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -27 dBm ... -6 dBm
Max. link distance single-mode fiber 40 km depending on customer
interface
Max. link distance 9/125 μm SM at 50 km
GbE
Bit error ratio < 10-12
SFP/3GSDI/#xxxxxV/SM/LC
The SFP/3GSDI/#xxxxxV/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at DWDM
wavelengths according to ITU-T G.694.1. The SFP/3GSDI/#xxxxxV/SM/LC
supports data rates for the transmission of SD-SDI, HD-SDI and 3G-SDI video
signals on the network ports.
This pluggable transceiver provides digital diagnostic monitoring of operating
parameters such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFP/3GSDI/ELECTRICAL/DIN
The SFP/3GSDI/ELECTRICAL/DIN is an MSA SFF-8074 compliant pluggable
transceiver that provides an electrical DIN1.0/2.3 interface for the support of
SD-SDI, HD-SDI and 3G-SDI video signals. It is intended for use in FSP
3000R7 modules with SFP interface cages on the client ports. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.
SFP/3GSDI/ELECTRICAL/HBNC
The SFP/3GSDI/ELECTRICAL/HBNC is an MSA SFF-8074 compliant
pluggable transceiver that provides an electrical high-density BNC (HD-BNC)
interface for the support of SD-SDI, HD-SDI and 3G-SDI video signals. It is
intended for use in FSP 3000R7 modules with SFP interface cages on the client
ports. Proper functionality and valid certification of transponder modules can be
guaranteed with SFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Degree of protection acc. to IEC IP20. Use in a pollution degree 2
60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 3,872,637 h
Electrical connector type HD-BNC
Cable type Belden 1694A coaxial cables, 75 Ω
Data rates 270 Mbit/s, 360 Mbit/s, 1.485 Gbit/s,
2.97 Gbit/s
Cable reach 400 m at 270 Mbit/s
300 m at 360 Mbit/s
200 m at 1.485 Gbit/s
140 m at 2.97 Gbit/s
SFP/HS/1310S/SM/LC
The SFP/HS/1310S/SM/LC is an MSA-compliant pluggable 1310 nm
transceiver for bidirectional communication over single-mode or multimode
fiber. It provides digital diagnostic monitoring of operating parameters such as
optical input power, temperature or laser bias. It is intended for use in FSP
3000R7 modules with SFP interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP types
approved by ADVA Optical Networking only.
SFP/CL/1310I/SM/LC
The SFP/CL/1310I/SM/LC is an MSA-compliant pluggable 1310 nm transceiver
for bidirectional communication over single-mode or multimode fiber. It provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. It is intended for use in FSP 3000R7 modules
with SFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA
Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Receiver fiber type MM 62.5 µm
Data rates 100 Mbit/s ... 2,67 Gbit/s
Transmitter output power range -10 dBm ... -3 dBm
Transmitter wavelength range 1260 nm ... 1360 nm
Min. extinction ratio 8.2 dB
Receiver wavelength range 1266 nm ... 1580 nm
Max. receiver reflectance 14 dB
Receiver dynamic range -19 dBm ... -3 dBm for data rates up to
2.5 Gbit/s
OPR/OPT accuracy +/- 3 dB
OPR measurement range -19 dBm ... 0 dBm
Max. link distance single-mode fiber 2 km depending on customer interface
Max. link distance multimode fiber 500 m depending on customer
interface
Bit error ratio < 10-12
SFP/2G1/850I/MM/LC
The SFP/2G1/850I/MM/LC is an MSA-compliant pluggable 850 nm transceiver
for bidirectional communication over multimode fiber. It provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias. It is intended for use in FSP 3000R7 modules with
SFP interface cages. Proper functionality and valid certification of transponder
modules can be guaranteed with SFP types approved by ADVA Optical
Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFP/GBE/1310S/SM/LC/TIN
The SFP/GBE/1310S/SM/LC/TIN is an MSA-compliant pluggable 1310 nm
transceiver for bidirectional communication over single-mode fiber. It provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. This pluggable transceiver supports an
operating temperature within the industrial temperature range (see Table 762).
It is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.
SFP/GBE/1310L/SM/LC/TIN
The SFP/GBE/1310L/SM/LC/TIN is an MSA-compliant pluggable 1310 nm
transceiver for bidirectional communication over single-mode fiber. It provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. This pluggable transceiver supports an
operating temperature within the industrial temperature range (see Table 763).
It is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 3,597,122 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rate 1.25 Gbit/s
Transmitter output power range -5 dBm ... +2 dBm
Transmitter wavelength range 1310 nm
Min. extinction ratio 9 dB
Receiver wavelength range 1260 nm ... 1360 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -23 dBm ... -3 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -20 dBm ... 0 dBm
Max. power penalty at dispersion 3.3 dB
Max. link distance 9/125 μm SM at GbE 40 km
Bit error ratio < 10-12
SFP/GBE/1550V/SM/LC/TIN
The SFP/GBE/1550V/SM/LC/TIN is an MSA-compliant pluggable 1550 nm
transceiver for bidirectional communication over single-mode fiber. It provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. This pluggable transceiver supports an
operating temperature within the industrial temperature range (see Table 764).
It is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.
SFP/GBE/850I/MM/LC/TIN
The SFP/GBE/850I/MM/LC/TIN is an MSA-compliant pluggable 850 nm
transceiver for bidirectional communication over multimode fiber. It provides
digital diagnostic monitoring of operating parameters such as optical input
power, temperature or laser bias. This pluggable transceiver supports an
operating temperature within the industrial temperature range (see Table 765).
It is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 15,680,400 h
Optical connector type Duplex LC
Transmitter fiber type MM 62.5 µm
Receiver fiber type MM 62.5 µm
Data rate 1.25 Gbit/s
Transmitter output power range -9.5 dBm ... 0 dBm
Transmitter wavelength range 850 nm
Min. extinction ratio 9 dB
Receiver wavelength range 770 nm ... 860 nm
Max. receiver reflectance 12 dB
Receiver dynamic range -17 dBm ... 0 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -20 dBm ... 0 dBm
Max. power penalty at dispersion 2 dB
Max. link distance
50/125 μm MMF 550 m
Bit error ratio < 10-12
SFP/GBE/B1310S/SM/LC
The SFP/GBE/B1310S/SM/LC is an MSA-compliant pluggable 1310 nm
transceiver for bidirectional communication over one single-mode fiber. It is
used in pair with a complementary bidirectional SFP which has a different
wavelength, e.g. the SFP/GBE/B1490S/SM/LC.
The SFP/GBE/B1310S/SM/LC provides digital diagnostic monitoring of
operating parameters such as optical input power, temperature or laser bias. It
is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.
SFP/GBE/B1490S/SM/LC
The SFP/GBE/B1490S/SM/LC is an MSA-compliant pluggable 1490 nm
transceiver for bidirectional communication over one single-mode fiber. It is
used in pair with a complementary bidirectional SFP which has a different
wavelength, e.g. the SFP/GBE/B1310S/SM/LC.
The SFP/GBE/B1490S/SM/LC provides digital diagnostic monitoring of
operating parameters such as optical input power, temperature or laser bias. It
is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 14,492,753 h
Optical connector type Simplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rate 1250 Mbit/s
Transmitter output power range -9 dBm ... -3 dBm
Transmitter wavelength 1490 nm
Min. extinction ratio 6 dB
Receiver wavelength range 1260 nm ... 1360 nm
Max. receiver reflectance -12 dB
Receiver dynamic range -20 dBm ... -3 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -22 dBm ... 0 dBm
Max. link distance single-mode fiber 10 km depending on customer
interface
Bit error ratio < 10-12
SFP/GBE/B1310L/SM/LC
The SFP/GBE/B1310L/SM/LC is an MSA-compliant pluggable 1310 nm
transceiver for bidirectional communication over one single-mode fiber. It is
used in pair with a complementary bidirectional SFP which has a different
wavelength, e.g. the SFP/GBE/B1490L/SM/LC.
The SFP/GBE/B1310L/SM/LC provides digital diagnostic monitoring of
operating parameters such as optical input power, temperature or laser bias. It
is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.
SFP/GBE/B1490L/SM/LC
The SFP/GBE/B1490L/SM/LC is an MSA-compliant pluggable 1490 nm
transceiver for bidirectional communication over one single-mode fiber. It is
used in pair with a complementary bidirectional SFP which has a different
wavelength, e.g. the SFP/GBE/B1310L/SM/LC.
The SFP/GBE/B1490L/SM/LC provides digital diagnostic monitoring of
operating parameters such as optical input power, temperature or laser bias. It
is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with SFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 14,285,714 h
Optical connector type Simplex LC
Transmitter fiber type SM
Receiver fiber type SM
Data rate 1250 Mbit/s
Transmitter output power range -3 dBm ... +2 dBm
Transmitter wavelength 1490 nm
Min. extinction ratio 6 dB
Receiver wavelength range 1260 nm ... 1360 nm
Max. receiver reflectance -12 dB
Receiver dynamic range -23 dBm ... -3 dBm
OPR/OPT accuracy +/- 3 dB
OPR measurement range -26 dBm ... 0 dBm
Max. link distance single-mode fiber 40 km depending on customer
interface
Bit error ratio < 10-12
SFP/GBE/Electrical/RJ45
The SFP/GBE/Electrical/RJ45 is a pluggable transceiver that provides an
electrical Gbit Ethernet port. It is intended for use in FSP 3000R7 modules with
SFP interface cages on client ports. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA
Optical Networking only.
This pluggable transceiver does not support link loss forwarding.
SFP/FE/C1490U/SM/LC
The SFP/FE/C1490U/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at 1490 nm. It
provides digital diagnostic monitoring of operating parameters such as optical
input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with SFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA
Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Receiver fiber type SM
Data rates 125 Mbit/s
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelengths 1490 nm
Transmitter wavelength range -7 nm ... +7 nm relative to nominal
wavelength
Min. extinction ratio 9 dB
Receiver wavelength range 1480 nm ... 1530 nm
Max. receiver reflectance 25 dB
Receiver dynamic range -42 dBm ... -9 dBm (BER < 10-7)
OPR/OPT accuracy +/- 3 dB
OPR measurement range -42 dBm ... -20 dBm
Min. dispersion load -1850 ps/nm
Optimum dispersion load 0 ps/nm
Max. dispersion load +3700 ps/nm
Max. power penalty at dispersion 2 dB at -1850 ps/nm
2 dB at +3700 ps/nm
SFP/FE/C1510U/SM/LC
The SFP/FE/C1510U/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at 1510 nm. It
provides digital diagnostic monitoring of operating parameters such as optical
input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with SFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA
Optical Networking only.
SFP/FE/C1490V/SM/LC
The SFP/FE/C1490V/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at 1490 nm. It
provides digital diagnostic monitoring of operating parameters such as optical
input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with SFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA
Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Receiver fiber type SM
Data rates 125 Mbit/s
Transmitter output power range 0 dBm ... +4 dBm
Transmitter wavelength 1490 nm
Transmitter wavelength range -7 nm ... +7 nm
relative to nominal wavelength
Min. extinction ratio 9 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1480 nm ... 1540 nm
Max. receiver reflectance 25 dB
Receiver dynamic range -30 dBm ... 0 dBm (BER < 10-7)
OPR/OPT accuracy +/- 3 dB
OPR measurement range -30 dBm to -15 dBm
Min. dispersion load -1850 ps/nm
Optimum dispersion load 0 ps/nm
Max. dispersion load 4000 ps/nm
Max. power penalty at dispersion 2 dB at -1850 ps/nm
2 dB at +4000 ps/nm
SFP/FE/C1510V/SM/LC
The SFP/FE/C1510V/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at 1510 nm. It
provides digital diagnostic monitoring of operating parameters such as optical
input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with SFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA
Optical Networking only.
SFP/FE/D1528.77E/SM/LC
The SFP/FE/D1528.77E/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at
1528.77 nm. It provides digital diagnostic monitoring of operating parameters
such as optical input power, temperature or laser bias. It is intended for use in
FSP 3000R7 OSCM-PN modules. The SFP/FE/D1528.77E/SM/LC does not
support the intrusion detection functionality of the OSCM-PN.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Data rates 125 Mbit/s
Transmitter output power range +4 dBm ... +7 dBm
Transmitter wavelengths 1528.77 nm
Transmitter wavelength range +0.1 nm relative to nominal wavelength
Min. extinction ratio 10 dB
Min. sidemode suppression ratio 30 dB
Receiver wavelength range 1260 ... 1610 nm
Max. receiver reflectance 27 dB
Receiver dynamic range -42 dBm ... -10 dBm (BER < 10-7)
OPR/OPT accuracy +/- 3 dB (for input power range
-40 ... -20 dBm only)
OPR measurement range -40 dBm ... -20 dBm
Min. dispersion load -2000 ps/nm
Optimum dispersion load 0 ps/nm
Max. dispersion load 4000 ps/nm
Max. power penalty at dispersion 2 dB at -2000 ps/nm
2 dB at +4000 ps/nm
SFP/FE/Dxxxx.xxV/SM/LC
The SFP/FE/Dxxxxx.xxV/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is available as
SFP/FE/D1531.12 V/SM/LC and SFP/FE/D1531.90V/SM/LC. It provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias. It is intended for use in FSP 3000R7 OSCM-PN
modules.
CFP/112G/LR10R/SM/LC
The CFP/112G/LR10R/SM/LC is an CFP MSA-compliant transceiver
(2 km) used to transmit high speed data rates of 103.125 Gbit/s and 111.81
Gbit/s for bidirectional communication over single-mode fiber. This CFP has an
integrated MUX and DEMUX filter for transmitting data signal divided into ten
optical WDM lanes supporting wavelengths. This transceiver provides digital
diagnostic monitoring of operating parameters such as optical input power,
temperature or laser bias.
It is intended for use in FSP 3000R7 modules with CFP interface cages on client
ports. Proper functionality and valid certification of transponder modules can be
guaranteed with CFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
controlled office environments
only.
MTBF at 25°C ambient temperature 2,066,115 h
Optical connector type Duplex LC
Transmitter fiber type SM
Receiver fiber type SM
Aggregate data rates 103.125 Gbit/s, 111.81 Gbit/s
Protocols 100 GbE, OTU4
Nominal data rates per optical lane
100 GbE 10.31 Gbit/s
OTU4 11.18 Gbit/s
Operating wavelengths 1523 nm, 1531 nm, 1539 nm,
1547 nm, 1555 nm, 1563 nm,
1571 nm, 1579 nm, 1587 nm,
1595 nm
Transmitter output power range, each -4.5 dBm ... +3.5 dBm
lane1
Optical modulation amplitude, each lane -3.9 dBm ... +3.0 dBm
(OMA2)
Max. transmitter and dispersion penalty 2.5 dB
(TDP), each lane
Max. optical lane transmitter output power 4 dB
difference
Max. total average transmitter output 13.5 dBm
power
Min. extinction ratio 2.5 dB
compliance.
ER – 1
OMA = P(optical1)-P(optical0) = 2 Pavg x ---------------
2. -
ER + 1
Pavg = Transmitter output power range
ER = Extinction ratio
3. Receiver dynamic range, each lane (min) is informative and not the principal
indicator of signal strength. A received power below this value cannot be
compliant; however, a value above this does not ensure compliance.
This table shows the faults reported for each of the 10 lanes contained within
the pluggable transceiver.
This table performance monitoring values reported for each of the 10 lanes
contained within the pluggable transceiver.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
CFP/112G/LR4/SM/LC
The CFP/112G/LR4/SM/LC is an MSA-compliant CFP transceiver used to
transmit high speed data rates of 103.125 Gbit/s and 111.81 Gbit/s for
bidirectional communication over single-mode fiber. This CFP has an integrated
MUX and DEMUX filter for transmitting data signal divided into four different
optical WDM lanes supporting wavelengths. It provides digital diagnostic
monitoring of operating parameters such as optical input power, optical output
power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with CFP interface cages on client
ports. Proper functionality and valid certification of transponder modules can be
guaranteed with CFP types approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Bit error ratio <10-12 at 100 GbE
Pre-Fec bit error ratio <10-12 at OTU4 with 3 dB power
penalty
<10-5 at OTU4
Max. module delay 200 ns
1. Transmitter output power range, each lane (min) is informative and not the
principal indicator of signal strength. A transmitter with output power below
this value cannot be compliant; however, a value above this does not ensure
compliance.
3. Receiver dynamic range, each lane (min) is informative and not the principal
indicator of signal strength. A received power below this value cannot be
compliant; however, a value above this does not ensure compliance.
This table shows the faults reported by each of the 4 optical lanes contained
within the pluggable transceiver.
Table 781: Fault Monitoring
Physical layer Laser failure;
Laser degrade (based on bias current);
Receiver clock synch failure;
Loss of signal (LOS)
This table shows the performance monitoring values reported for each of the 4
optical lanes within the pluggable transceiver.
CFP/103G/SR10/MM/MPO
The CFP/103G/SR10/MM/MPO is an MSA-compliant CFP transceiver, SR10
type, used to transmit high speed data rate of 103.125 Gbit/s for bidirectional
communication over multimode fiber.
This CFP transceiver module offers ten independent transmit and receive
channels, each capable of 10.3 Gbit/s operation per lane to enable support for
103G (100GBASE-SR10) rate. It provides separate fibre connection per optical
lane through a single MPO24 port which connects to an industry standard 2x12
parallel multimode fiber cable (4 optical lanes are not used).
The CFP/103G/SR10/MM/MPO is intended for use in FSP 3000R7 modules
with CFP interface cages on client ports. Proper functionality and valid
certification of transponder modules can be guaranteed with CFP types
approved by ADVA Optical Networking only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Module type CFP
Max. weight 300 g (0.7 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 1,769,171 h
Optical connector type MPO24
Transmitter fiber type MM
Receiver fiber type MM
Aggregate data rates 103.125 Gbit/s
Protocols 100 GbE
Nominal data rates per optical lane 10.3125 Gbit/s
100 GbE
Optical lane wavelengths range 840 nm to 860 nm
(according to IEEE 802.3ba-2010)
Transmitter output power range, -7.6 dBm ... +2.4 dBm
each lane1
Optical modulation amplitude -5.6 dBm ... +3 dBm
(OMA2), each lane
Max. transmitter and dispersion 3.5 dB
penalty (TDP), each lane
Max. optical lane transmitter output 4 dB
power difference
3. Receiver dynamic range, each lane (min) is informative and not the principal
indicator of signal strength. A received power below this value cannot be
compliant; however, a value above this does not ensure compliance.
The following table lists the faults reported by each of the 10 optical lanes
contained within the CFP transceiver.
Table 784: Fault Monitoring
Physical layer Loss of signal (LOS)
(One defect instance supported per Loss of clock
optical lane of transceiver) Laser failure;
The front cover of the SH9HU shelf cannot be used due to the MPO
PS
CFP/4x28G/#19xxx-#19xxxL/SM/LC
The CFP/4x28G/#19xxx-#19xxxL/SM/LC is an MSA-compliant CFP transceiver
used to transmit high speed data rates of 103.125 Gbit/s and 111.81 Gbit/s for
bidirectional communication over single-mode fiber. For data transmission the
signal is divided into four optical WDM lanes supporting DWDM C-band
channels according to ITU-T G.694.1.
This type of CFP is available in five variants:
• CFP/4x28G/#19595-#19520L/SM/LC
• CFP/4x28G/#19515-#19440L/SM/LC
• CFP/4x28G/#19435-#19360L/SM/LC
• CFP/4x28G/#19355-#19280L/SM/LC
• CFP/4x28G/#19275-#19200L/SM/LC
Each variant supports fixed channel spacing at 100 GHz between the optical
lanes. The lanes can be tuned as a block to four different nominal frequencies in
a 50 GHz, 400 GHz or 450 GHz offset grid. Tuning is performed by setting the
frequency of the first optical lane in the system management using the NE
management tools. With these 5 variants and their tuning capabilities 80
wavelengths are supported in the C band.
The CFP/4x28G/#19xxx-#19xxxL/SM/LC provides digital diagnostic monitoring
of operating parameters such as optical input power, temperature or laser bias.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
It is intended for use in FSP 3000R7 modules with CFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with CFP types approved by ADVA Optical Networking only.
The optical performance values listed below are specified for a 50 GHz grid filter
system. The CFP/4x28G/#19xxx-#19xxxL/SM/LC can be used in a 100 GHz
grid filter system as well. In this case penalties have to be taken into account.
Contact ADVA Optical Networking’s Network Consulting for details, please.
Dispersion load range with 1 dB OSNR -400 ps/nm to -250 ps/nm and
penalty +250 ps/nm to +400 ps/nm
OSNR penalty
at 2.3 ps PMD for BER < 10-3 1 dB (outage probability 4x10-5)
at 3.3 ps PMD for BER < 10-3 2 dB (outage probability 4x10-5)
at 4.6 ps PMD for BER < 10-3 4 dB (outage probability 4x10-5)
at 2.3 ps PMD for BER < 5 x 10-5 1.5 dB (outage probability 4x10-5)
at 3.3 ps PMD for BER < 5 x 10-5 2.5 dB (outage probability 4x10-5)
at 4.6 ps PMD for BER < 5 x 10-5 4.5 dB (outage probability 4x10-5)
OPR/OPT accuracy +/-3 dB
Bit error ratio < 5 x 10-5 at 23 dB OSNR (0.1 nm)
<10-3 at 19 dB OSNR (0.1 nm)
Max. module delay 200 ns
This table shows the faults reported by each of the optical lanes contained
within the pluggable transceiver.
Table 787: Fault Monitoring
Physical layer Laser failure;
Laser degrade (based on bias current);
Receiver clock synch failure;
Loss of signal
This table shows the performance monitoring values reported for each of the
optical lanes within the pluggable transceiver.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
CFP/4x28G/#DCTL/SM/LC
The CFP/4x28G/#DCTL/SM/LC is an MSA-compliant CFP transceiver used to
transmit high speed data rates of 103.125 Gbit/s and 111.81 Gbit/s for
bidirectional communication over single-mode fiber. For data transmission the
signal is divided into four optical WDM lanes supporting DWDM C-band
channels according to ITU-T G.694.1.
This transceiver supports fixed channel spacing at 100 GHz between four
optical lanes. The lanes can be tuned as a block to 90 different nominal
frequencies at a 50 GHz channel grid between 196.00 THz and 191.25 THz.
Tuning is performed by setting the frequency of the first optical lane in the
system management using the NE management tools.
The CFP/4x28G/#DCTL/SM/LC provides digital diagnostic monitoring of
operating parameters such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with CFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed
with CFP types approved by ADVA Optical Networking only.
The optical performance values listed below are specified for a 50 GHz grid filter
system. The CFP/4x28G/#DCTL/SM/LC can be used in a 100 GHz grid filter
system as well. In this case penalties have to be taken into account. Contact
ADVA Optical Networking’s Network Consulting for details, please.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Bit error ratio < 5 x 10-5 at 23 dB OSNR (0.1 nm)
<10-3 at 19 dB OSNR (0.1 nm)
Max. module delay 200 ns
1. Tuning to 96 channels is possible with NE SW 12.1 or higher. NE SW 11.2.3
allows tuning to 8o channels only.
This table shows the faults reported by each of the optical lanes contained
within the pluggable transceiver.
Table 790: Fault Monitoring
Physical layer Laser failure;
Laser degrade (based on bias current);
Receiver clock synch failure;
Loss of signal (LOS)
This table shows the performance monitoring values reported for each of the
optical lanes within the pluggable transceiver.
“SCU” on p. 495
“SCU-II” on p. 497
“SCU-S” on p. 499
“VSM” on p. 501
“RSM-OLM#1630” on p. 503
“OSCM-PN” on p. 505
NCU-II
The network element control unit of the second generation (NCU-II) provides
the FSP 3000R7 System with a network connection and system management
capabilities.
An FSP 3000R7 node is managed via the NCU-II. This interface uses Internet
protocols to provide management and configuration capabilities. The NCU-II
controls the modules in its own shelf and those in the other shelves on one node
via the shelf control unit (SCU/SCU-S/SCU-II). Only one NCU-II is supported
per node.
The NCU-II is accessible via a terminal program or Ethernet using telnet, FTP,
HTTP, SCP, SNMP and NTP.
The NCU-II’s command line system allows fast (local) interaction. External
Network Management Systems (NMSs) are supported via SNMP over the
Ethernet interface.
Table 792 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Weight 310 g (0.7 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Typ. power consumption 6 W (NCU-II used in one shelf and
with 25°C ambient temperature)
Max. power consumption 9W
Max. available RAM (excluding 900000 Kbytes
tolerance buffer, RAM disk, initial
RAM consumption)
MTBF at 25°C ambient temperature 531,251 h
Slot position SH9HU, SH7HU, SH7HU-R,
SH1HU-HP/2DC, SH1HU-F/2DC,
SH1HU-HP/E-TEMP/2DC, SH1HU-R
and SH1HU-R/PF: slot A
The following table contains information about the hardware reset possibility.
NCU-II-P
The network element control unit (NCU-II-P) provides system management
capabilities and network connection to the FSP 3000R7 system. The NCU-II-P
is a single-slot full height (5HU) plug-in module, that acts as the main network
element controller and offers different management interfaces (SNMP, WEB,
Craft, TL1, etc) to the outside world via ethernet, serial or in-band management
connections. It interfaces with and controls all equipment in the system. The
NCU-II-P can be used only in a redundant configuration together with another
NCU-II-P in one shelf to protect against single point of communication failures.
Please note: Continuous operation of a single NCU-II-P in a shelf is not
intended. The NCU-II-P always waits for a second standby NCU-II-P in the
same shelf.
The NCU-II-P only works with the second-generation shelf control unit (SCU-II).
The NCU-II-P communicates with the SCU-II in the master shelf using an inter-
nal system bus. Exchange of information between the SCU-II in the master shelf
and the SCU-IIs in the additional shelves takes place over the management
fiber ring.
The NCU-II-P can be accessed through a serial, Mini USB or Ethernet port.
Table 798 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Equipment type NCU-II-P
First release 11.2
Width 4 HP
Height 5 HU
Weight 500 g (1.102 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Typ. power consumption 9 W (NCU-II-P used in one shelf and
with 25°C ambient temperature)
Max. power consumption 11 W
Max. available RAM (excluding 2 Gbit
tolerance buffer, RAM disk, initial
RAM consumption)
MTBF at 25°C ambient temperature 446,428 h
Slot positions SH9HU: slots 3 and 18 in shelf #1
The following table contains information about the hardware reset possibility.
UTM
The UTM (Utility Module) features 3 Ethernet interfaces for management access
and a telemetry interface with dry contacts for 16 external opto-isolated inputs
and 4 output signals. The alarm status of these input/output signals is visualized
to the user via 20 LEDs. An alarm reset button allows resetting the alarm status
of the output contacts as well as the associated output LEDs. It does not clear
the alarm status of the affected alarms in the management system.
Table 804 shows general information about the UTM and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Max. power consumption 10 W
Maximum RAM consumption on 269 Kbytes
NCU
MTBF at 25°C ambient temperature 548,507 h
Slot position SH9HU, SH7HU, SH7HU-R: 3...18
SH1HU: slot 1, 2
The following table shows information about telemetry alarm input parameters.
The following table contains information about the hardware reset possibility.
PSCU
The PSCU (Passive Shelf Control Unit) acts as the controller for
40CSM/2HU-#Dxx-#Dyy and 96CSM/4HU-#19600-#19125 shelves. The PSCU
recognizes all available 40CSM/2HU-#Dxx-#Dyy shelves and allows monitoring
and controlling. The PSCU is the connecting point of any
40CSM/2HU-#Dxx-#Dyy and 96CSM/4HU-#19600-#19125 shelf to support
management functionality. It basically registers the shelf to the NE controller
and provides inventory data and power supply. A maximum of eight
40CSM/2HU-#Dxx-#Dyy and 96CSM/4HU-#19600-#19125 shelves can be
connected to one PSCU via the interconnect ports.
Table 811 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
office environments only.
Typ. power consumption 3 W (+ 0.5 W per 40CSM shelf)
Max. power consumption 10 W
Maximum RAM consumption on 91 Kbytes
NCU
MTBF at 25°C ambient temperature 1,476,814 h
Slot position SH9HU, SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
SCU
The Shelf Control Unit (SCU) supports the internal and external communication
of a shelf. It is responsible for module registration/deregistration and module
extraction supervision. The SCU provides redundant inter-shelf communication.
Table 814 provides general information about the module and its environment.
SM for SFP/2G5U/1310S/SM/LC
(HW Rev. 2.01)
Max. link distance 200 m with 62.5 µm MM
500 m with 50 µm MM (OM3)
15 km with SM between two shelves
(The total fiber length between all
shelves in one network element must
not exceed 35 km.)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 818: Module Monitoring
Temperature board temperature in °C
Voltage power fail
Monitored states SFP state, link state
SCU-II
The SCU-II (shelf control unit second generation) is a single-slot 2.5 HU high
plug-in module, which acts as a communication gateway between the NCU and
modules for an entire main shelf. It recognizes all inserted optical modules and
downloads their configuration data stored in the NCU. The SCU-II has
increased RAM, ROM and CPU performance and is fully compatible with other
SCUs. The module is also designed to operate with the NCU-II-P in redundant
configurations.
Table 819 provides general information about the module and its environment.
SM for SFP/2G5U/1310S/SM/LC
(HW Rev. 2.01)
Max. link distance 200 m with 62.5 µm MM
500 m with 50 µm MM (OM3)
15 km with SM between two shelves (The total
fiber length between all shelves in one network
element must not exceed 35 km.)
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Port U SFP/2G1/850I/MM/LC
(HW Rev. 1.02 or newer)
SFP/2G5U/1310S/SM/LC
(HW Rev. 2.01)
Port D SFP/2G1/850I/MM/LC
(HW Rev. 1.02 or newer)
SFP/2G5U/1310S/SM/LC
(HW Rev. 2.01)
SCU-S
The Shelf Control Unit (SCU-S) supports the internal and external
communication of the SH1HU shelves. It is responsible for module
registration/deregistration and module extraction supervision. The SCU-S
provides inter-shelf communication. A maximum of two SH1HU shelves can be
connected to build one Network Element.
Table 824 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
VSM
The Versatile Switch Module (VSM) is for optically switched protection
purposes. In the case of a network failure the VSM gets messages from the
2OSCM-V#1630 or OSCM-PN to process protection switching.
These commands are transmitted via the internal communication system
(backplane and SCU-SCU). Only in configurations with 2OSCM-V#1630 or
OSCM-PN, equipped with two network SFPs, the backup path can be
monitored. The VSM can work on a line, band, subband, group or channel
basis. It can be deployed in protected point-to-point topologies as well as in ring
topologies.
Table 828 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
RSM-OLM#1630
The Remote Switch Module with Optical Line Monitoring (RSM-OLM#1630) is
used to provide optical line monitoring and line protection. Pilot lasers are used
to monitor the optical lines for fiber cuts, fiber intrusion and fiber
degradation/aging. The thresholds defining fiber intrusion and signal degrade
are user configurable. Protection switching takes place in the event of LOS
(fiber break) or fiber degradation (signal degrade). As long as both network fiber
pairs are available, the non-active fiber pair can be used to transmit low priority
traffic.
Table 833 provides general information about the module and its environment.
Table 836 provides information about the optical line monitoring characteristics.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
network ports.
OSCM-PN
The OSCM-PN is an optical supervisory channel module with optical line
monitoring and dual pluggable optical network interfaces for east-west
applications. The pluggable network interfaces allow flexibility in the selection of
various OSC wavelengths and fiber spans. The module has an integrated
Ethernet switch and three Ethernet ports on the client side. The OSCM-PN
performs a layer-2-switching between the electrical and optical Ethernet ports.
In addition, this module integrates an optical line monitoring facility which
enables to monitor the optical lines for fiber break and fluctuations of fiber
attenuation. The optical line monitoring relies on OPR measurements.
Therefore the OLM functionality is only available when the SFP is operated
inside of the specified OPR measurement range. See specifications of SFP for
details. This module is a central component of the DCN.
The OSCM-PN can be employed for:
• providing the OSC as an integral part of the laser safety mechanisms in
Raman amplifier configurations using a wavelength of 1528.77 nm
• DCN communication in dual-fiber working configurations using an OSC
wavelength of 1510 nm
• DCN communication in single-fiber working configurations using an OSC
wavelength of 1490 nm and 1510 nm
• DCN communication (32/40ch systems only) in configuration with the
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
1310 nm types SFP/2G5U/1310L/SM/LC (supported in
OSCM-PN with HW Rev. 3.01 or newer
only)
1490 nm types SFP/FE/C1490U/SM/LC
SFP/FE/C1490V/SM/LC
1510 nm types SFP/FE/C1510U/SM/LC
SFP/FE/C1510V/SM/LC
CWDM types SFP/2G5U/CxxxxV/SM/LC (supported in
OSCM-PN with HW Rev. 3.01 or newer
only)
DWDM types SFP/FE/D1528.77E/SM/LC
SFP/FE/Dxxxxx.xxV/SM/LC1 (supported
in OSCM-PN with HW Rev. 3.01 or newer
only)
SFP/2G5U/#Dxxxx.xxU/SM/LC#Dxx1
with HW Rev. 3.01 or newer (only C band
is supported
1. The signal from these DWDM SFPs must not pass ROADMs.
This chapter describes reconfigurable optical layer devices of the FSP 3000R7.
The following sections are provided:
“ROADM-C80/0/OPM” on p. 510
“8ROADM-C40/0/OPM” on p. 516
“8ROADM-C80/0/OPM” on p. 521
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
“9ROADM-C96/0/OPM” on p. 526
“4ROADM-C96/0/OPM” on p. 532
“CCM-C40/8” on p. 537
“CCM-C80/8” on p. 541
“CCM-C96/9” on p. 545
“4-OPCM” on p. 550
ROADM-C80/0/OPM
The ROADM-C80/0/OPM is used for channel add/drop and/or optical power
control. The ROADM-C80/0/OPM also provides the ability to monitor individual
channel power levels. The ROADM-C80/0/OPM can be used in a number of
different node configurations that include Optical Terminal Multiplexer (OTM),
Reconfigurable Optical Add Drop Multiplexer (ROADM) and Line-amp. In most
applications the ROADM-C80/0/OPM modules will be used in pairs.
The ROADM-C80/0/OPM can be provisioned to handle up to 40 C-band
channels with 100 GHz channel spacing or 80 C-band channels with 50 GHz
channel spacing.
An integrated optical power monitor (OPM) in the ROADM-C80/0/OPM module
allows power balancing on a per wavelength basis at the network port.
The forward and backward fault indicators on channel module ports (controlled
by the ERRFWD and ALSMODE parameters) must not be set to disable the
optical channel. The ALSMODE parameter must be set to "None" and the
ERRFWD parameter must not be set to "Laser Off". If these parameters cannot
be set to these setting then the module should not be used when the optical
channel passes through the ROADM-C80/0/OPM.
Below is a simplified block diagram of the ROADM-C80/0/OPM.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ROADM-C80/0/OPM
U-M
N-M WSS
C-M
U-D
N-D Splitter
C-D
Table 846 provides general information about the module and its environment.
The following table provides information about the optical characteristics of the
network port.
The following table provides information about the optical characteristics of the
client ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
560 pm (70 GHz) for 100 GHz
channel spacing acc. to ITU-T
G.694
Latency C-M to N-M 58 ns
This table shows information about the optical characteristics of the upgrade
port.
This table shows information about fault monitoring of the module in general.
This table shows information about fault monitoring of the client port in general.
This table shows information about fault monitoring of the upgrade port in
general.
This table shows information about fault monitoring of the network port in
general.
The following table shows information about fault monitoring of the virtual
channel (virtual channel representing single channel).
This table shows information about performance monitoring of the client port.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 857: Performance Monitoring Client Interface - General
Physical layer Optical power Rx (current, low,
(15 min/24 h records available for PM mean, high)
values;
User configurable threshold crossing
alerts for OPR too high/too low available)
This table shows information about performance monitoring of the upgrade port.
8ROADM-C40/0/OPM
The 8ROADM-C40/0/OPM is an FSP 3000R7 module that functions as a
transparent Reconfigurable Optical Add Drop Multiplexer. As part of the FSP
3000R7 optical layer, the module enables nodes to support network
configurations like ring interconnections using 4 degrees or fully meshed
topologies up to 8 degrees.
The module supports the following optical channel configurations:
• Add/Drop
• Pass-through
• Drop/Continue
The 8ROADM-C40/0/OPM contains one duplex network interface (or degree)
and 8 duplex client interfaces. The received network signal is split into 8
identical copies, which are available at the client port outputs. One or two client
ports may be used for local add/drop which are followed by optical filters
(1CSM, 4CSM, 40CSM). The other client ports are connected to the client ports
of other 8ROADM-C80/0/OPM modules to support channel transmission to
different degrees. An integrated optical power monitor (OPM) in the module
allows power balancing on a per wavelength basis at the network port output.
The NCU limits the number of supported degrees (network interfaces) to four.
The NCU-II supports up to 8 degrees.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The forward and backward fault indicators on channel module ports (controlled
by the ERRFWD and ALSMODE parameters) must not be set to disable the
optical channel. The ALSMODE parameter must be set to "None" and the
ERRFWD parameter must not be set to "Laser Off" . If these parameters cannot
be set to these setting then the module should not be used when the optical
channel passes through the 8ROADM-C40/0/OPM.
Below is a simplified block diagram of the 8ROADM-C40/0/OPM.
Table 861 provides general information about the module and its environment.
The following table provides information about the optical characteristics of the
network port.
The following table provides information about the optical characteristics of the
client ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Whether fault/performance monitoring entries listed in the
PS
This table shows information about fault monitoring of the module in general.
This table shows information about fault monitoring of the client ports in general.
This table shows information about fault monitoring of the network ports in
general.
The following table shows information about fault monitoring of the virtual
channel (virtual channel representing single channel).
This table shows information about performance monitoring of the client ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
8ROADM-C80/0/OPM
The 8ROADM-C80/0/OPM is an FSP 3000R7 module that functions as a
Reconfigurable Optical Add Drop Multiplexer. As part of the FSP 3000R7 optical
layer, the module enables nodes to support network configurations like ring
interconnections using 4 degrees or fully meshed topologies up to 8 degrees.
The module supports the following optical channel configurations:
• Add/Drop
• Pass-through
• Drop/Continue
The 8ROADM-C80/0/OPM contains one duplex network interface (or degree)
and 8 duplex client interfaces. The received network signal is split into 8
identical copies, which are available at the client port outputs. One or two client
ports may be used for local add/drop which are followed by optical filters
(1CSM, 4CSM, 40CSM). The other client ports are connected to client ports of
other 8ROADM-C80/0/OPM modules to support channel transmission to
different degrees. An integrated optical power monitor (OPM) in the module
allows power balancing on a per wavelength basis at the network port output.
The NCU limit the number of supported degrees (network interfaces) to four.
The NCU-II supports up to 8 degrees.
The forward and backward fault indicators on channel module ports (controlled
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
by the ERRFWD and ALSMODE parameters) must not be set to disable the
optical channel. The ALSMODE parameter must be set to "None" and the
ERRFWD parameter must not be set to "Laser Off". If these parameters cannot
be set to these setting then the module should not be used when the optical
channel passes through the 8ROADM-C80/0/OPM.
Figure 6 illustrates a simplified block diagram of the 8ROADM-C80/0/OPM.
8ROADM-C80/0/OPM
C1-D
C2-D
C3-D
PD 1x8 C4-D
N-D Splitter C5-D
C6-D
C7-D
C8-D
PDs
Switch OPM C1-M
C2-M
C3-M
8x1 C4-M
N-M
WSS C5-M
C6-M
C7-M
C8-M
Table 873 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table provides information about the module’s optical characteristics.
The following table provides information about the optical characteristics of the
network port.
The following table provides information about the optical characteristics of the
client ports.
This table shows information about fault monitoring of the module in general.
This table shows information about fault monitoring of the client ports in general.
This table shows information about fault monitoring of the network ports in
general.
The following table shows information about fault monitoring of the virtual
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
channel (virtual channel representing single channel).
This table shows information about performance monitoring of the client ports.
9ROADM-C96/0/OPM
The 9ROADM-C96/0/OPM is an FSP 3000R7 module that functions as a Net-
work wavelength switching point. The 9ROADM-C96/0/OPM module can be
deployed alongside existing FSP 3000R7 modules in an FSP 3000R7 Network
Element (NE). The 9ROADM-C96/0/OPM operates with the NCU-II and
NCU-II-P which support up to 9 degrees (network interfaces) for add-drop appli-
cations or 10 degrees for tandem switch applications.
An FSP 3000R7 NE containing 9ROADM-C96/0/OPM modules supports linear,
ring, ring interconnect, and mesh network configurations.The
9ROADM-C96/0/OPM module enables provisioning and adjustment of add-drop
and pass-through DWDM C-band channels and supports these optical connec-
tion configurations:
• Add-drop
• Pass-through
• Add
• Drop
The 9ROADM-C96/0/OPM module can handle 96 C-band channels with 50
GHz spacing. It contains one duplex network interface and 9 duplex Client inter-
faces. The N-C path (N-R to Cx-T) signal is split into 9 identical copies, which
are available on the module front panel at the Cx-T outputs. For local drop con-
nections, one or two of these C-band outputs are typically used, and the others
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
are routed to additional 9ROADM-C96/0/OPM modules in the node for transmis-
sion to one or more degrees.
The C-N path (Cx-R to N-T) allows selection of up to 96 different C-band chan-
nels from the Cx-R inputs for transmission on the N-T output. Typically, the
Cx-R inputs are connected from the other 9ROADM-C96/0/OPM modules and
the local add connections. The add and drop connections are connected to opti-
cal filters or any add-drop Fixed or Directionless structure associated with that
degree.
The 9ROADM-C96/0/OPM also has improved transient control, allowing for bet-
ter regulation of variations in channel amplitudes.
Figure 7 illustrates a simplified block diagram of the 9ROADM-C96/0/OPM.
1x9 Splitter
PD PD
N-R C5-T
Amplifer
C6-T
C7-T
C8-T
C9-T
PDs
Switch C1-R
C2-R
C3-R
OCM C4-R
PD
9x1 WSS
N-T C5-R
C6-R
C7-R
C8-R
C9-R
Table 885 provides general information about the module and its environment.
Width 16 HP
Height 5 HU
Weight 3200g (7.054lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 150,000 h
Typ. power consumption 55 W
Max. power consumption 90 W
Slot positions SH9HU: 3 ... 15
NCU types NCU-II and NCU-II-P
The following table provides information about the optical characteristics of the
network port.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
N-T output per channel power (equalized) -24 dBm ... -12 dBm
Max. non-uniformity between received 7 dB
channels
The following table provides information about the optical characteristics of the
client ports.
This table shows information about fault monitoring of the module in general.
This table shows information about fault monitoring of the client ports in general.
This table shows information about fault monitoring of the network ports in gen-
eral.
The following table shows information about fault monitoring of the virtual chan-
nel (virtual channel representing single channel).
The following table shows information about fault monitoring of the EDFA sub-
module.
This table shows information about performance monitoring of the client ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
values except current values; Optical power Tx (current, low,
User configurable threshold crossing mean, high)
alerts for Optical Power Rx high/low are
available;
Fix threshold crossing alerts for Optical
Power Tx high/low are available)
The following table shows information about performance monitoring of the vir-
tual channel (virtual channel representing single channel).
This table shows information about performance monitoring of the virtual chan-
nel at client port.
4ROADM-C96/0/OPM
The 4ROADM-C96/0/OPM is an FSP 3000R7 module that functions as a Net-
work wavelength switching point. The 4ROADM-C96/0/OPM module can be
deployed alongside existing FSP 3000R7 modules in an FSP 3000R7 Network
Element (NE). The 4ROADM-C96/0/OPM operates with the NCU-II and
NCU-II-P which support up to 4 degrees (network interfaces) for add-drop appli-
cations or 5 degrees for tandem switch applications.
An FSP 3000R7 NE containing 4ROADM-C96/0/OPM modules supports linear,
ring, ring interconnect, and mesh network configurations.The
4ROADM-C96/0/OPM module enables provisioning and adjustment of add-drop
and pass-through DWDM C-band channels and supports these optical connec-
tion configurations:
• Add-drop
• Pass-through
• Add
• Drop
The 4ROADM-C96/0/OPM module can handle 96 C-band channels with 50
GHz spacing. It contains one duplex network interface and 4 duplex Client inter-
faces. The N-C path (N-R to Cx-T) signal is split into 4 identical copies, which
are available on the module front panel at the Cx-T outputs. For local drop con-
nections, one or two of these C-band outputs are typically used, and the others
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
are routed to additional 4ROADM-C96/0/OPM modules in the node for transmis-
sion to one or more degrees.
The C-N path (Cx-R to N-T) allows selection of up to 96 different C-band chan-
nels from the Cx-R inputs for transmission on the N-T output. Typically, the
Cx-R inputs are connected from the other 4ROADM-C96/0/OPM modules and
the local add connections. The add and drop connections are connected to opti-
cal filters or any add-drop Fixed or Directionless structure associated with that
degree.
Figure 7 illustrates a simplified block diagram of the 4ROADM-C96/0/OPM.
C1-T
1x4 Splitter
C2-T
N-R
C3-T
C4-T
2:1 Switch
OCM C1-R
C2-R
4x1 WSS
N-T
C3-R
C4-R
Table 885 provides general information about the module and its environment.
The following table provides information about the optical characteristics of the
network port.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
N-T total output power (to equalize) -24 dBm ... 11 dBm
N-T output per channel power (to equalize) -24 dBm ... -9 dBm
Max. non-uniformity between received 8.0 dB
channels
The following table provides information about the optical characteristics of the
client ports.
This table shows information about fault monitoring of the module in general.
This table shows information about fault monitoring of the client ports in general.
This table shows information about fault monitoring of the network ports in gen-
eral.
The following table shows information about fault monitoring of the virtual chan-
nel (virtual channel representing single channel).
This table shows information about performance monitoring of the client ports.
The following table shows information about performance monitoring of the vir-
tual channel (virtual channel representing single channel).
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
CCM-C40/8
The CCM-C40/8 (8-port Colorless Channel Module) is an 8 port reconfigurable
filter that allows any wavelength in the 40 channel multiplex to be dropped or
added at a node without changing any hardware. In the de-multiplex path the
CCM-C40/8 connects one channel from the optical multiplex of up to 40
channels on the network port to one of the 8 client ports. In the multiplex path
the module takes the input from all 8 client ports and optically combines them
into an optical multiplex of up to 40 channels and connects them to the network
port.
CCM modules require optical channel power to be present for proper operation.
Therefore, channel modules with channels that pass through these modules
must be set as follows:
· Auto Laser Shutdown must be set to Disable.
· Error Forwarding Mode must not be set to Laser Off.
These parameters can cause the channel module laser to be turned off. If these
parameters cannot be set to the specified setting then the module should not be
used when the optical channel passes through the CCM-C40/8.
Below is a simplified block diagram of the CCM-C40/8.
C1-M
C2-M
C3-M
C4-M
N-M Combiner
C5-M
C6-M
C7-M
C8-M
C1-D
C2-D
C3-D
N-D WSS C4-D
C5-D
C6-D
C7-D
C8-D
Table 912 provides general information about the module and its environment.
The following table provides information about the optical characteristics of the
network port.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 914: Optical Characteristics - Network Port
N-M total output power -25 dBm ... 14 dBm
N-M output per channel power -25 dBm ... -2 dBm
N-D total input power -10 dBm ... 21 dBm
N-D input per channel power -10 dBm ... 7 dBm
N-D max non-uniformity between channels 9 dB
N-D to C-D unpowered insertion loss > 40 dB
Return loss > 35 dB
N-D to C-D passband at 3 dB 400 pm (50 GHz)
N-D to C-D latency 62 ns
Table below provides information about the optical characteristics of the client
ports.
This table shows information about fault monitoring of the module in general.
This table shows information about fault monitoring of the client ports in general.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table shows information about fault monitoring of the network ports in
general.
This table shows information about performance monitoring of the client ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
CCM-C80/8
The CCM-C80/8 (8-port Colorless Channel Module) is an 8 port reconfigurable
filter that allows any wavelength in the 80 channel multiplex to be dropped or
added at a node without changing any hardware. In the de-multiplex path the
CCM-C80/8 connects one channel from the optical multiplex of up to 80
channels on the network port to one of the 8 client ports. In the multiplex path
the module takes the input from all 8 client ports and optically combines them
into an optical multiplex of up to 80 channels and connects them to the network
port.
CCM modules require optical channel power to be present for proper operation.
Therefore, channel modules with channels that pass through these modules
must be set as follows:
· Auto Laser Shutdown must be set to Disable.
· Error Forwarding Mode must not be set to Laser Off.
These parameters can cause the channel module laser to be turned off. If these
parameters cannot be set to the specified setting then the module should not be
used when the optical channel passes through the CCM-C80/8.
Below is a simplified block diagram of the CCM-C80/8.
C1-M
C2-M
C3-M
PD 8x1 C4-M
N-M
Combiner C5-M
C6-M
C7-M
C8-M
PDs
C1-D
C2-D
C3-D
PD 1x8 C4-D
N-D
WSS C5-D
C6-D
C7-D
C8-D
Table 922 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table provides information about the optical characteristics of the
network port.
Table below provides information about the optical characteristics of the client
ports.
This table shows information about fault monitoring of the module in general.
This table shows information about fault monitoring of the client ports in general.
This table shows information about fault monitoring of the network ports in
general.
This table shows information about performance monitoring of the client ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
CCM-C96/9
CCM‐C96/9
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
C1-T
C2-T
C3-T
Amplifier Sub
- assembly
C4-T
9x1 WSS
N-R C5-T
Pre-
Amp C6-T
C7-T
PD PD
C8-T
C9-T
PD Array
C2-R
C3-R
OCM
C4-R
Combiner
N-T C5-R
1x9
C6-R
C7-R
PD
C8-R
Power C9-R
UCM
Supply /
Microprocessor
Distribution
This table provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Number of channels per port 96 (19125 to 19600)
Channel spacing 50 GHz
Wavelength range 1529 nm ... 1568 nm
Optical connector type LC
Fiber type SM G.652
This table provides information about the optical characteristics of the network
port.
This table provides information about the optical characteristics of the client
ports.
This table shows information about fault monitoring of the module in general.
This table shows information about fault monitoring of the client ports in general.
This table shows information about fault monitoring of the network ports in
general.
This table shows information about fault monitoring of the virtual channel at the
network port.
The following table shows information about fault monitoring of the EDFA sub-
module.
This table shows information about performance monitoring of the client ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
alerts for OPR High/Low are available)
This table shows information about performance monitoring of the virtual chan-
nel at the client port.
This table shows information about performance monitoring of the virtual chan-
nel at the network port.
4-OPCM
The 4-OPCM (Optical Power Control Module) is a single-slot plug-in module
with 4 optical network interfaces. Each network port features an individually
controllable variable optical attenuator (VOA) and an optical power monitor. The
4-OPCM is intended to be used as a replacement for pluggable fixed
attenuators for optical power balancing or optical power control purposes. The
4-OPCM has two different operation modes, constant attenuation mode (CA)
and constant output power mode (CP).
All provisioned parameters controlling the function of the 4-OPCM (e.g.
operational mode for each VOA, set attenuation, set output power, etc.) will be
stored persistently on the module.
Table 947 provides general information about the 4-OPCM and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Typ. power consumption 1.7 W
Max. power consumption 3W
Maximum RAM consumption on 82 Kbytes
NCU
MTBF at 25°C ambient temperature 1,198,977 h
Slot positions SH9HU: 3 ... 18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types All NCU
Max. latency 0.05 µs
“40CSM/2HU-#Dxx-#Dyy” on p. 558
“40CSM/2HU-#19590-#19200” on p. 560
“40CSM/2HU-#19595-#19205” on p. 562
“40CSM-FL/2HU-#19590-#19200” on p. 564
“40CSM-C80/2HU-#19xxx-#19yyy” on p. 566
“40CSM/P-2HU#19590-#19200-DM” on p. 568
“96CSM/4HU-#19600-#19125” on p. 570
“2BSM-#D01-#D32” on p. 572
“4GSM-#Dxx-#Dyy” on p. 574
“8GSM-#D01-#D32” on p. 576
“1GSM+#Dxx-#Dyy” on p. 578
“5GSM-#19590-#19200” on p. 580
“8CSM-#19xxx-#19yyy” on p. 582
“4CSM+#19xxx-#19yyy” on p. 585
“4CSM-#Dxx-#Dyy” on p. 587
“4CSM+#Dxx-#Dyy” on p. 589
“1CSM+#Dxx-E/W” on p. 591
“1CSM+#19xxx-E/W” on p. 593
“2CLSM-#D01-#D64-SFx” on p. 595
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
“2-OTFM+#1650” on p. 635
“5PSM” on p. 637
“8PSM” on p. 638
“PSM-95/5” on p. 640
“2PSM-95/5” on p. 641
“1PM/SM” on p. 643
“1PM/MM” on p. 644
“2PM/SM” on p. 645
“2PM/MM” on p. 646
“Y-Cable/SM” on p. 647
“Y-Cable/MM” on p. 649
“J/SM/4CS-#C1270-#C1330/LC/0400” on p. 651
ILM50-#DC
The ILM50-#DC is an optical module specifically designed for DWDM in
Dual-Fiber Point-to-Point, linear add/drop, ring and meshed configurations. It
multiplexes and de-multiplexes the “even” and “odd” wavelength channels of the
C band into one fiber pair. "Even" channels refer to the channels with
frequencies of 196.00 THz to 192.00 THz (#D01 to #D32) with a spacing of 100
GHz, while “odd” channels refer to the channels with frequencies of 195.95 THz
to 192.05 THz with a spacing of 100 GHz as well. The total system capacity can
be doubled by upgrading existing 40 channel systems (100 GHz grid) to 80
channels (50 GHz) in the C band.
Table 950 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
2CLSM-#D01-#D64
The 2CLSM-#D01-#D64 is an optical C-band/L-band splitter that acts as a C/L
band splitter and combiner for DWDM in dual-fiber point-to-point configurations.
The following table contains general information about the 2CLSM.
40CSM/2HU-#Dxx-#Dyy
The 40CSM/2HU-#Dxx-#Dyy is a monolithic shelf of 2 HU height without any
kind of modularity supporting the multiplexing and demultiplexing even channels
in dual fiber DWDM point to point configurations.
There are 2 separate shelves, one for the C band and one for the L band:
40CSM/2HU-#D02-#D32 (C band), 40CSM/2HU-#D34-#D64 (L band)
Table 958 provides general information on the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
environments only.
Power consumption 0.5 W
Maximum RAM consumption on 167 Kbytes
NCU
MTBF at 25°C ambient temperature 1,694,915 h
40CSM/2HU-#19590-#19200
The 40CSM/2HU-#19590-#19200 is a monolithic shelf of 2 HU height without
any kind of modularity supporting the multiplexing and demultiplexing of even
channels for fibers to the right in dual fiber DWDM point to point configurations.
Thus it provides 40 client ports and one network port.
Table 962 provides general information on the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Power consumption 0.5 W
Maximum RAM consumption on 167 Kbytes
NCU
MTBF at 25°C ambient temperature 1,694,915 h
40CSM/2HU-#19595-#19205
The 40CSM/2HU-#19595-#19205 is a monolithic shelf of 2 HU height without
any kind of modularity supporting the multiplexing and demultiplexing of odd
channels in dual fiber DWDM point to point configurations. Thus it provides 40
client ports and one network port.
Table 966 provides general information on the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Power consumption 0.5 W
Maximum RAM consumption on 167 Kbytes
NCU
MTBF at 25°C ambient temperature 1,694,915 h
40CSM-FL/2HU-#19590-#19200
The 40CSM-FL/2HU-#19590-#19200 is a monolithic shelf of 2 HU height
without any kind of modularity supporting the multiplexing and demultiplexing of
even channels for fibers to the left in dual fiber DWDM point to point
configurations. Thus it provides 40 client ports and one network port.
Table 970 provides general information on the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Power consumption 0.5 W
Maximum RAM consumption on 167 Kbytes
NCU
MTBF at 25°C ambient temperature 1,694,915 h
40CSM-C80/2HU-#19xxx-#19yyy
The 40CSM-C80/2HU-#19xxx-#19yyy is a 40-port MUX/DMX channel
splitter/combiner 2HU shelf - C-band channels. It is only be used for dual client
configurations in conjunction with an 8ROADM-C80/0/OPM for an 80-channel
C-band transmission system supporting 50 GHz channel spacing.
There are 2 separate shelves, one for the even C-band channels and one for the
odd C-band channels:
40CSM-C80/2HU-#19590-#19200 (even C-band channels),
40CSM-C80/2HU-#19595-#19205 (odd C-band channels)
Table 974 provides general information on the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2 envi-
IEC 60529 ronment and indoor controlled office
environments only.
Power consumption 0.5 W
Maximum RAM consumption on 167 Kbytes
NCU
MTBF at 25°C ambient temperature 1,694,915 h
40CSM/P-2HU#19590-#19200-DM
The 40CSM/P-2HU#19590-#19200-DM is a passive 40-port MUX/DMX channel
splitter and combiner 2HU shelf with monitoring port for dual power level
monitoring. It is a monolithic shelf of 2 HU height including channel MUX and
DEMUX filters and monitor taps.
Table 978 provides general information on the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Weight 4.2 kg (9.3 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1,
extended temperature range -25°C to
+70°C with insertion loss penalty
Degree of protection according to IP20. Use in a pollution degree 2 envi-
IEC 60529 ronment and indoor controlled office
environments only.
Power consumption -
MTBF at 25°C ambient temperature 1,639,344 h
96CSM/4HU-#19600-#19125
The 96CSM/4HU-#19600-#19125 is a monolithic shelf of 4 HU height without
any kind of modularity supporting the multiplexing and demultiplexing of 96
C-band channels. Thus it provides 96 client ports and one network port. In
addition, the shelf has one fiber detection client port and one fiber detection
network port for monitoring the availability of the attached fibers.
In addition the 96CSM/4HU-#19600-#19125 can be used in 80 channel systems
as replacement of 2x40CSM plus ILM.
Table 982 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
2.3
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2 envi-
IEC 60529 ronment and indoor controlled office
environments only.
Power consumption 0.5 W
Maximum RAM consumption on 393 Kbytes
NCU
MTBF at 25°C ambient temperature 337,268 h
Directivity > 45 dB
Passband width 120 pm (15 GHz)
Latency < 35 ns
Insertion loss client fiber detection port Rx to < 22 dB
client port Tx
Insertion loss network port Rx to network < 1.3 dB
fiber detection port Tx
Directivity client fiber detection port Rx to cli- > 45 dB
ent fiber detection port Tx
Isolation network fiber detection port Tx > 25 dB
Passband network fiber detection port Tx 1290 nm - 1330 nm
2BSM-#D01-#D32
The 2BSM-#D01-#D32 is an optical module that acts as a red/blue subband
splitter and combiner for DWDM in linear add/drop and ring configurations.
The 2BSM-#D01-#D32 contains a combination of specific subband MUX and
DEMUX filters that combine/split the red and blue subband channel signals of
the C band into/from the full duplex signal carried by the network fiber pair. The
blue subbands comprise the shorter wavelengths, channels #D01-#D16. The
red subbands include the longer wavelengths, channels #D17-#D32.
Table 986 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 10,000,000 h
Power consumption 1.2 W
Maximum RAM consumption on 26 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
This table shows information about the optical characteristics of the multiplexer.
The following table provides information about the optical characteristics of the
demultiplexer.
4GSM-#Dxx-#Dyy
The 4GSM-#Dxx-#Dyy is an optical channel group splitter and combiner
module. The module is available in two variants (4GSM-#D01-#D16 and
(4GSM-#D17-#D32) for supporting the C-band channels.
Table 990 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
This table shows information about the optical characteristics of the multiplexer.
Latency < 75 ns
8GSM-#D01-#D32
The 8GSM-#D01-#D32 is an optical channel group splitter and combiner
module. The module supports the channels #D01 through #D32 of the C band.
Table 994 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SH7HU, SH7HU-R: 3...17
SH1HU: 1
This table shows information about the optical characteristics of the multiplexer.
Table 996: Optical Characteristics - Multiplexer
Insertion loss max. value
#D01-#D04 3.8 dB (port C1)
#D05-#D08 3.3 dB (port C2)
#D09-#D12 2.8 dB (port C3)
#D13-#D16 2.3 dB (port C4)
#D17-#D20 3.5 dB (port C5)
#D21-#D24 3 dB (port C6)
#D25-#D28 2.5 dB (port C7)
#D29-#D32 2 dB (port C8)
Insertion loss typical value
#D01-#D04 1.8 dB (port C1)
#D05-#D08 1.5 dB (port C2)
#D09-#D12 1.2 dB (port C3)
#D13-#D16 1 dB (port C4)
#D17-#D20 1.6 dB (port C5)
#D21-#D24 1.3 dB (port C6)
#D25-#D28 1.1 dB (port C7)
#D29-#D32 0.8 dB (port C8)
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 105 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
1GSM+#Dxx-#Dyy
The 1GSM+#Dxx-#Dyy is an optical channel group splitter and combiner
module.
There are 8 separate modules for all C-band groups:
1GSM+#D01-#D04, 1GSM+#D05-#D08, 1GSM+#D09-#D12,
1GSM+#D13-#D16, 1GSM+#D17-#D20, 1GSM+#D21-#D24,
1GSM+#D25-#D28, 1GSM+#D29-#D32
Table 998 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Maximum RAM consumption on 24 Kbytes
NCU
MTBF at 25°C ambient temperature 26,315,790 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
This table shows information about the optical characteristics of the multiplexer.
This table shows information about the optical characteristics of the multiplexer.
5GSM-#19590-#19200
The 5GSM-#19590-#19200 is a 5-port optical channel group splitter and
combiner module. The module contains optical filters, that combine/split five
separate channel group signals. It performs multiplex and de-multiplex
operation on a full duplex network fiber pair.
Table 1002 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
This table shows information about the optical characteristics of the multiplexer.
8CSM-#19xxx-#19yyy
The 8CSM-#19xxx-#19yyy is an optical 8-port DWDM channel splitter and
combiner module for the C band.
There are five module variants covering the C band:
8CSM-#19590-#19520, 8CSM-#19510-#19440, 8CSM-#19430-#19360,
8CSM-#19350-#19280, 8CSM-#19270-#19200
Table 1006 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Maximum RAM consumption on NCU 35 Kbytes
MTBF at 25°C ambient temperature 3,649,635 h
Slot positions SH9HU: 3...17
SH7HU, SH7HU-R: 3...17
SH1HU: 1
This table shows information about the optical characteristics of the multiplexer.
The following table provides information about the optical characteristics of the
demultiplexer.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
4CSM+#19xxx-#19yyy
The 4CSM+#19xxx-#19yyy is a 4- port optical channel splitter and combiner
module.
The module contains a combination of specific MUX/DEMUX filters which
allows access to specific channels of the C band from a network fiber while
passing through the remaining channel spectrum.
There are 10 separate modules covering C-band channels:
4CSM+#19590-#19560, 4CSM+#19550-#19520, 4CSM+#19510-#19480,
4CSM+#19470-#19440, 4CSM+#19430-#19400, 4CSM+#19390-#19360,
4CSM+#19350-#19320, 4CSM+#19310-#19280, 4CSM+#19270-#19240,
4CSM+#19230-#19200
Table 1010 provides general information about the module and its environment.
This table shows information about the optical characteristics of the multiplexer.
The following table provides information about the optical characteristics of the
demultiplexer.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Insertion loss max. value (port dependent)
port C1 2 dB
port C2 2.4 dB
port C3 2.8 dB
port C4 3.2 dB
for upgrade port 1.6 dB
Insertion loss typical value (port dependent)
port C1 1.2 dB
port C2 1.4 dB
port C3 1.6 dB (port C3)
port C4 1.8 dB (port C4)
for upgrade port 0.6 dB
Directivity > 50 dB
Isolation for adjacent channels > 30 dB
Optical return loss > 40 dB
Passband width 250 pm (31.25 GHz)
Latency < 90 ns
4CSM-#Dxx-#Dyy
The 4CSM-#Dxx-#Dyy is an optical channel splitter and combiner module. It
contains a combination of MUX and DEMUX channel filters for the C band.
There are 8 separate modules for all C-band groups:
4CSM-#D01-#D04, 4CSM-#D05-#D08, 4CSM-#D09-#D12, 4CSM-#D13-#D16,
4CSM-#D17-#D20, 4CSM-#D21-#D24, 4CSM-#D25-#D28, 4CSM-#D29-#D32
Table 1014 provides general information about the module and its environment.
NCU
MTBF at 25°C ambient temperature 17,241,380 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
This table shows information about the optical characteristics of the multiplexer.
The following table provides information about the optical characteristics of the
demultiplexer.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
#D02, #D06, #D10... 1.8 dB (port C2)
#D03, #D07, #D11... 2.2 dB (port C3)
#D04, #D08, #D12... 2.6 dB (port C4)
Insertion loss typical value
#D01, #D05, #D09... 0.7 dB (port C1)
#D02, #D06, #D10... 1 dB (port C2)
#D03, #D07, #D11... 1.2 dB (port C3)
#D04, #D08, #D12... 1.4 dB (port C4)
Isolation for adjacent channels > 30 dB
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 250 pm (31.25 GHz)
Latency < 75 ns
4CSM+#Dxx-#Dyy
The 4CSM+#Dxx-#Dyy is an optical channel splitter and combiner module.
The module contains a combination of specific add/drop optical filters and
MUX/DEMUX filters which allows access to four specific channels of the C band
from a network fiber while passing through the remaining channel spectrum.
There are 8 separate modules for all C-band groups:
4CSM+#D01-#D04, 4CSM+#D05-#D08, 4CSM+#D09-#D12,
4CSM+#D13-#D16, 4CSM+#D17-#D20, 4CSM+#D21-#D24,
4CSM+#D25-#D28, 4CSM+#D29-#D32
Table 1018 provides general information about the module and its environment.
This table shows information about the optical characteristics of the multiplexer.
The following table provides information about the optical characteristics of the
demultiplexer.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Insertion loss max. value (port dependent)
#D01, #D05, #D09... 2 dB (port C1)
#D02, #D06, #D10... 2.4 dB (port C2)
#D03, #D07, #D11... 2.8 dB (port C3)
#D04, #D08, #D12... 3.2 dB (port C4)
for upgrade port 1.4 dB
Insertion loss typical value (port dependent)
#D01, #D05, #D09... 1.2 dB (port C1)
#D02, #D06, #D10... 1.4 dB (port C2)
#D03, #D07, #D11... 1.6 dB (port C3)
#D04, #D08, #D12... 1.8 dB (port C4)
for upgrade port 0.6 dB
Directivity > 50 dB
Isolation for adjacent channels > 30 dB
Optical return loss > 40 dB
Passband width 250 pm (31.25 GHz)
Latency < 90 ns
1CSM+#Dxx-E/W
The 1CSM+#Dxx-E/W is an optical east/west single channel DWDM splitter and
combiner module. On a per-wavelength basis it allows access to a specific
channel from an east-side and west-side network fiber pair while passing the
remaining channel spectrum.
There are 32 separate modules:
1CSM+#D01-E/W, 1CSM+#D02-E/W, 1CSM+#D03-E/W, 1CSM+#D04-E/W,
1CSM+#D05-E/W, 1CSM+#D06-E/W, 1CSM+#D07-E/W, 1CSM+#D08-E/W,
1CSM+#D09-E/W, 1CSM+#D10-E/W, 1CSM+#D11-E/W, 1CSM+#D12-E/W,
1CSM+#D13-E/W, 1CSM+#D14-E/W, 1CSM+#D15-E/W, 1CSM+#D16-E/W,
1CSM+#D17-E/W, 1CSM+#D18-E/W, 1CSM+#D19-E/W, 1CSM+#D20-E/W,
1CSM+#D21-E/W, 1CSM+#D22-E/W, 1CSM+#D23-E/W, 1CSM+#D24-E/W,
1CSM+#D25-E/W, 1CSM+#D26-E/W, 1CSM+#D27-E/W, 1CSM+#D28-E/W,
1CSM+#D29-E/W, 1CSM+#D30-E/W, 1CSM+#D31-E/W, 1CSM+#D32-E/W
Table 1022 provides general information on the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Isolation > 55 dB for drop port
> 26 dB for upgrade port
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 30 ns
1CSM+#19xxx-E/W
The 1CSM+#19xxx-E/W is an optical east/west single channel DWDM splitter
and combiner module. On a per-wavelength basis it allows access to a specific
C band channel from an east-side and west-side network fiber pair while
passing the remaining channel spectrum.
There are 9 separate modules for specific channels in the C band:
1CSM+#19560-E/W, 1CSM+#19510-E/W, 1CSM+#19460-E/W,
1CSM+#19410-E/W, 1CSM+#19400-E/W, 1CSM+#19390-E/W,
1CSM+#19340-E/W, 1CSM+#19290-E/W, 1CSM+#19240-E/W
Table 1026 provides general information on the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 30 ns
2CLSM-#D01-#D64-SFx
The 2CLSM-#D01-#D64-SFx is an optical module that acts as C/L band splitter
and combiner for DWDM in single-fiber working point-to-point configurations.
The “x” at the end of the module name stands for the location A or B.
The 2CLSM-#D01-#D64-SFA multiplexes the channels #D01-#D16 and
#D33-#D48, and demultiplexes the channels #D17-#D32 and #D49-#D64, while
the 2CLSM-#D01-#D64-SFB demultiplexes the channels #D01-#D16 and
#D33-#D48 and multiplexes the channels #D17-#D32 and #D49-#D64.
Table 1030 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
16CSM-#D01-#D32-SFx
The 16CSM-#D01-#D32-SFx is a bi-directional channel splitter and combiner
for DWDM in single-fiber point-to-point configurations. It includes a combination
of specific channel and channel group MUX/DEMUX filters that handle the
combining/splitting individual channels within the C band (#D01 to #D32)
into/from the full duplex network signal.
Table 1034 provides general information about the module and its environment.
This table shows information about the optical characteristics of the multiplexer.
Table 1036: Optical Characteristics - Multiplexer
Insertion loss Cx-M to Booster-T (port dependent)
C1, C2, C3, C4, 6.7 dB, 6.3 dB, 5.9 dB, 5.5 dB
C5, C6, C7, C8, 6.3 dB, 5.9 dB, 5.5 dB, 5.1 dB
C9, C10, C11, C12 5.9 dB, 5.5 dB, 5.1 dB, 4.7 dB
C13, C14, C15, C16 5.5 dB, 5.1 dB, 4.7 dB, 4.3 dB
Insertion loss typical value (port dependent)
C1, C2, C3, C4 2.9 dB, 2.7 dB, 2.4 dB, 2.3 dB
C5, C6, C7, C8 2.6 dB, 2.4 dB, 2.3 dB, 2.1 dB
C9, C10, C11, C12 2.4 dB, 2.2 dB, 2 dB, 1.7 dB
C13, C14, C15, C16 2.4 dB, 2.1 dB, 1.8 dB, 1.7 dB
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Isolation for adjacent channels > 30 dB
Directivity > 50 dB
Return loss network port > 40 dB
Return loss Preamp-T > 40 dB
Passband width 250 pm (31.25 GHz)
Latency Preamp-T to Cx-D < 150 ns
Latency network port to Preamp-R < 30 ns
16CSM-#D33-#D64-SFx
The 16CSM-#D33-#D64-SFx is a bi-directional channel splitter and combiner
for DWDM in single-fiber point-to-point configurations. It includes a combination
of specific channel and channel group MUX/DEMUX filters that handle the
combining/splitting of individual channels within the L band (#D33 to #D64)
into/from the full duplex network signal.
Table 1038 provides general information about the module and its environment.
Table below contains information about the optical connector and fiber type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Isolation for adjacent channels > 30 dB
Directivity > 50 dB
Return loss > 40 dB
Passband width 250 pm (31.25 GHz)
Latency Preamp-T to Cx-D < 150 ns
Latency network port to Preamp-R < 30 ns
OSFM+#1490-SFA
The OSFM+#1490-SFA (optical supervisory channel filter module - single-fiber
working, location A) adds the OSC #1490 to and drops the OSC #1510 from the
DWDM spectrum on the single network fiber while passing through the DWDM
spectrum.
This module can only be used in conjunction with the complemental
OSFM+#1510-SFB installed on the other side of the communication link.
Table 1042 provides general information about the module and its environment.
Table below contains information about the optical connector and fiber type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Directivity > 50 dB
Optical return loss > 40 dB
Passband width 1504.5 nm to 1517.5 nm
Latency < 60 ns
OSFM+#1510-SFB
The OSFM+#1510-SFB (optical supervisory channel filter module - single-fiber
working, location B) adds the OSC #1510 to and drops the OSC #1490 from the
DWDM spectrum on the single network fiber while passing through the DWDM
spectrum.
This module can only be used in conjunction with the complemental
OSFM+#1490-SFA installed on the other side of the communication link.
Table 1046 provides general information about the module and its environment.
The following table contains information about the optical connector and fiber
type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
2ABSM-#C1470-#C1610
The 2ABSM-#C1470-#C1610 is an optical 2-port CWDM subband splitter
module.
The module serves as combiner and splitter of two groups of multiplexed
CWDM channels. One group comprises the channels #C1470, #C1490,
#C1590 and #C1610 with the corresponding center wavelengths 1471 nm,
1491 nm, 1591 nm and 1611 nm. The other group includes the channels
#C1510, #C1530, #C1550 and #C1570 with the center wavelengths 1511 nm,
1531 nm, 1551 nm and 1571 nm.
The 2ABSM-#C1470-#C1610 incorporates a combination of specific MUX and
DEMUX band filters. These filters multiplex/demultiplex the wavelength bands
of the two groups of channels into/from one full duplex signal carried by the
network fiber pair.
Table 1050 provides general information about the module and its environment.
The following table contains information about the optical characteristics of the
demultiplexer.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
3BSM-#G1310-#C1610
The 3BSM-#G1310-#C1610 is an optical CWDM band splitter module with gray
interface at 1310 nm .
The module serves as combiner and splitter of two groups of multiplexed
CWDM channels. One group comprises the channels #C1470, #C1490,
#C1590 and #C1610 with the corresponding center wavelengths 1471 nm, 1491
nm, 1591 nm and 1611 nm. The other group includes the channels #C1510,
#C1530, #C1550 and #C1570 with the center wavelengths 1511 nm, 1531 nm,
1551 nm and 1571 nm. In addition, it enables the transmission of a gray channel
(#G1310) over the CWDM network without having to upgrade existing
infrastructure and without affecting running services.
The respective wavelengths are
1471 nm, 1491 nm, 1591 nm and 1611 nm for one channel group,
1511 nm, 1531 nm, 1551 nm, 1571 nm for the other channel group and
1310 nm.
Table 1054 provides general information about the module and its environment.
Height 5 HU
Weight 530 g (1.17 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 2,500,000 h
Power consumption 1.2 W
Maximum RAM consumption on 20 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
The following table contains information about the optical connector and fiber
type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Insertion loss typical value
1310 nm 1 dB (port C1)
1470 nm, 1490 nm, 1590 nm, 1610 nm 1.1 dB (port C2)
1510 nm, 1530 nm, 1550 nm, 1570 nm 1 dB (port C3)
Directivity > 50 dB
Optical return loss > 40 dB
Isolation > 30 dB
Latency < 75 ns
4CSM-#Cxxxx-#Cyyyy
The 4CSM-#Cxxxx-#Cyyyy is an optical 4-port CWDM channel splitter and
combiner module. It contains a combination of MUX and DEMUX channel filters
for the above mentioned groups of channels. One group comprises the
channels #C1470, #C1490, #C1590 and #C1610 with the corresponding center
wavelengths 1471 nm, 1491 nm, 1591 nm and 1611 nm. The other group
includes the channels #C1510, #C1530, #C1550 and #C1570 with the center
wavelengths 1511 nm, 1531 nm, 1551 nm and 1571 nm.
Table 1058 provides general information about the module and its environment.
This table shows information about the optical characteristics of the multiplexer.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
1491 nm, 1531 nm 1.8 dB (port C2)
1551 nm, 1591 nm 1.6 dB (port C3)
1571 nm, 1611 nm 1.4 dB (port C4)
Insertion loss typical value
1471 nm, 1511 nm 1.4 dB (port C1)
1491 nm, 1531 nm 1.1 dB (port C2)
1551 nm, 1591 nm 1 dB (port C3)
1571 nm, 1611 nm 0.7 dB (port C4)
Passband width 13 nm according to ITU-T G.694
Isolation for adjacent channels > 30 dB
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 30 ns
8CSM+#C1470-#C1610
The 8CSM+#C1470-#C1610 is an optical 8-port CWDM channel splitter module
with upgrade port.
The module allows access to a single gray channel (#G1310) from a network
fiber and splits/combines the entire CWDM channel spectrum which ranges
from #C1470 to #C1610.
The 8CSM+#C1470-#C1610 contains a combination of specific add/drop optical
filters and MUX/DEMUX filters.
Table 1062 provides general information about the module and its environment.
Table below contains information about the optical connector and fiber type.
This table shows information about the optical characteristics of the multiplexer.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
typical value
Passband width client ports 13 nm according to ITU-T G.694
Passband width upgrade port 77 nm
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 105 ns
1CSM+#G1310
The 1CSM+#G1310 is an optical CWDM Single Channel Splitter Module with
1310-nm connectivity. The module allows access to a single gray channel
(#G1310) from a network fiber while passing CWDM/DWDM channels. The
1CSM+#G1310 contains a combination of specific add/drop optical filters.
These filters perform the add/drop function on the pre-defined wavelengths
around 1310 nm.
Table 1066 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Maximum RAM consumption on 36 Kbytes
NCU
MTBF at 25°C ambient temperature 4,761,905 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
This table shows information about the optical characteristics of the multiplexer.
1CSM+#Cxxxx
The 1CSM+#Cxxxx is an optical single channel CWDM splitter and combiner
module. On a per-wavelength basis, it allows access to a specific channel from
a network fiber while passing the remaining channel spectrum. The
1CSM+#Cxxxx contains a combination of specific add/drop optical filters. These
filters add/drop a specific channel to/out of the CWDM channel spectrum while
reflecting all other channels onto the upgrade port according to the CWDM
wavelengths grid.
There are 8 separate modules:
1CSM+#C1470, 1CSM+#C1490, 1CSM+#C1510, 1CSM+#C1530,
1CSM+#C1550, 1CSM+#C1570, 1CSM+#C1590, 1CSM+#C1610.
The respective center wavelengths are 1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm and 1611 nm.
Table 1070 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption 1.2 W
Maximum RAM consumption on 32 Kbytes
NCU
MTBF at 25°C ambient temperature 4,672,897 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
The following table contains information about the optical connector and fiber
type.
This table shows information about the optical characteristics of the multiplexer.
5GSM/P-#19590-#19200-DM
The 5GSM/P-#19590-#19200-DM is a passive 5-port DWDM channel group
splitter and combiner module with monitoring port for dual power level
monitoring. It is designed for use in an SH1HU/PASSIVE/FT shelf only.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ETSI EN 300 019-1-3 Class 3.1,
extended temperature range -25°C to
+70°C with insertion loss penalty
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 14,705,883 h
Power consumption -
Slot positions 1, 3 of SH1HU/PASSIVE/FT only
8CSM/P-#C1470-#C1610-DM
The 8CSM/P-#C1470-#C1610-DM is a passive 8-port CWDM channel splitter
module with monitoring port for dual power level monitoring. It is intended for
use in an SH1HU/PASSIVE/FT shelf only.
Table 1078 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption -
MTBF at 25°C ambient temperature 3,448,276 h
Slot positions 1, 3 of SH1HU/PASSIVE/FT only
This table shows information about the optical characteristics of the multiplexer.
2BSM/P-#C1270-#C1610-DM
The 2BSM/P-#C1270-#C1610-DM is a passive 2-port CWDM band splitter
module with gray interface at 1310 nm and monitoring port for dual power level
monitoring.
The module allows access either to additional CWDM channels in the range
between C#1270 and C#1450 or to gray channel (#G1310) from a network fiber
while passing through the CWDM channels (#1470 - #1610) used by ADVA
Optical Networking.
Table 1082 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Weight 530 g (1.17 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1,
extended temperature range -25°C to
+70°C with insertion loss penalty
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 4,347,826 h
Power consumption -
Slot positions 1 ... 4 in an SH1HU/PASSIVE/FT only
8CSM/P+#C1470-#C1610-DM
The 8CSM/P+#C1470-#C1610-DM is a passive 8-port CWDM channel splitter
module with upgrade port and dual monitoring points for external Optical
Spectrum Analyzers (OSA). It is intended for use in an SH1HU/PASSIVE/FT
shelf only.
Table 1086 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
without insertion loss penalty,
extended temperature range -25°C to
+70°C with insertion loss penalty
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption -
MTBF at 25°C ambient temperature 5,344,418 h
Slot positions 1, 3 of SH1HU/PASSIVE/FT only
This table shows information about the optical characteristics of the multiplexer.
8CSM/P-#19xxx-#19yyy
The 8CSM/P-#19xxx-#19yyy is a passive 8-port DWDM channel splitter and
combiner module. It is designed for use in an SH1HU/PASSIVE/FT shelf.
There are five separate modules in the C band covering DWDM channels:
8CSM/P-#19590-#19520, 8CSM/P-#19510-#19440, 8CSM/P-#19430-#19360,
8CSM/P-#19350-#19280, 8CSM/P-#19270-#19200
Table 1090 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
ETSI EN 300 019-1-3 Class 3.1,
extended temperature range -25°C to
+70°C with insertion loss penalty
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
Power consumption -
MTBF at 25°C ambient temperature 3,649,635 h
Slot positions 1, 3 of SH1HU/PASSIVE/FT only
This table shows information about the optical characteristics of the multiplexer.
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 135 ns
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
8CSM/P-#C1270-#C1450
The 8CSM/P-#C1270-#C1450 is a passive 8-port CWDM channel splitter
module with monitoring port. It is intended for use in an SH1HU/PASSIVE/FT
shelf only.
Table 1094 provides general information about the module and its environment.
This table shows information about the optical characteristics of the multiplexer.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical return loss > 40 dB
Latency < 20 ns
1CSM/P+#Cxxxx
The 1CSM/P+#Cxxxx is a passive optical single channel CWDM splitter and
combiner module with upgrade port. The module contains a combination of
specific add/drop optical filters. These filters add/drop a specific channel to/out
of the CWDM channel spectrum while reflecting all other channels onto the
upgrade port.
Table below contains information about the optical connector and fiber type.
This table shows information about the optical characteristics of the multiplexer.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
range -25°C to +70°C
Passband width 13 nm according to ITU-T G.694
Isolation > 30 dB for drop port,
> 12 dB for upgrade port
Directivity > 50 dB
Optical return loss > 40 dB
Latency < 30 ns
OSFM+#1510
The OSFM+#1510 is an optical supervisory channel filter module with upgrade
port. It is used to add/drop an optical supervisory channel (OSC #1510)
into/from the network fiber while passing through the DWDM channel spectrum.
The OSFM+#1510 is only required in configurations where an OSCM-PN
equipped with an SFP/FE/C1510V/SM/LC is to be used.
Table 1102 provides general information about the module and its environment.
NCU
MTBF at 25°C ambient temperature 30,618,494 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
This table shows information about the optical characteristics of the multiplexer.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
2-OTFM+#1650
The 2-OTFM+#1650 is an optical time-domain reflectometer filter module with
upgrade port. It is used to add/drop of one or two OTDR signals at a wavelength
of #1650 nm on one or two network fibers for network monitoring. CWDM or
DWDM channel spectrum is forwarded between the network and network
element.
Table 1106 provides general information about the module and its environment.
NCU
MTBF at 25°C ambient temperature 31,918,289 h
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
5PSM
The 5PSM (5 Port Splitter Combiner Module) is a power splitter module
specifically designed for the deployment of an CCM-C40/8 or CCM-C80/8.
Table 1109 provides general information about the module and its environment.
SH1HU: 1, 2
8PSM
The 8PSM (8 Port Splitter Module) is designed to divide the optical channels
received by the network port into identical copies for output on all client ports.
The module combines optical channels received on the client ports for output on
the network port.
Table 1112 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Slot positions SH9HU: 3...17
SH1HU: 1
PSM-95/5
The PSM-95/5 is a power splitter module specifically designed for power
monitoring and optical spectrum analysis. It contains a splitter that splits the
optical power of the input signal into two portions.
Table 1115 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
2PSM-95/5
The 2PSM-95/5 is a dual power splitter module specifically designed for power
monitoring and optical spectrum analysis. The module contains two
bi-directional power splitters that monitor the optical power of a received and
transmitted signal. The signal paths are split with 5% of the signal directed to a
monitor port.
Table 1118 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
1PM/SM
The 1PM/SM (single-port protection module single-mode) is an optical module
that provides channel card protection. It has one client port and accepts
single-mode signals.
The 1PM/SM splits one optical signal received on the client port into two
duplicate signals for output on the network ports west and east. In the other
direction, the module combines the optical signals received on each network
port into an multiplex for output on the client port.
Table 1121 provides general information about the module and its environment.
1PM/MM
The 1PM/MM (single-port protection module multimode) is an optical module
that provides channel card protection. It has one client port and accepts
single-mode and multimode signals.
The 1PM/MM splits one optical signal received on the client port into two
duplicate signals for output on the network ports west and east. In the other
direction, the module combines the optical signals received on each network
port into an multiplex for output on the client port.
Table 1124 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 20,833,333 h
Power consumption 1.2 W
Maximum RAM consumption on 31 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
2PM/SM
The 2PM/SM (2-port protection module single-mode) is an optical module that
provides channel card protection. It has two client ports and accepts
single-mode signals only. The 2PM/SM splits two optical signals received on the
client ports into four duplicate signals for output on the network ports west and
east. In the other direction, the module combines the optical signals received on
each network ports into an multiplex for output on the client ports.
Table 1127 provides general information about the module and its environment.
The following table contains information about the optical connector and fiber
type.
2PM/MM
The 2PM/MM (2-port protection module multimode) is an optical module that
provides channel card protection. It has two client ports and accepts multimode
signals only.
The 2PM/MM splits two optical signals received on the client ports into four
duplicate signals for output on the network ports west and east. In the other
direction, the module combines the optical signals received on each network
ports into an multiplex for output on the client ports.
Table 1130 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 10,416,666 h
Power consumption 1.2 W
Maximum RAM consumption on 27 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
Y-Cable/SM
The y-cable/SM (single-mode y-cable) is a 3-port fiber-optic cable with an
integrated 50/50 coupler facilitate channel card protection. It has one client port,
two network ports and accepts single-mode signals only.
The single mode y-cable splits one optical signal received on the client port
(single end) into two duplicate signals for output on the network ports 1 and 2. In
the other direction, the cable combines the optical signals received on each
client port into an multiplex for output on the client port.
The single-mode y-cable can be used either the Transmit (Tx) or Receive (Rx)
direction at either end of a fiber span.
The single-mode y-cable is available in six variants:
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Y-Cable/MM
The y-cable/MM (62.5 µm multimode y-cable) is a 3-port fiber-optic cable with
an integrated 50/50 coupler to facilitate channel card protection. It has one client
port, two network ports and accepts multimode signals only.
The 62.5 µm multimode y-cable splits one optical signal received on the client
port (single end) into two duplicate signals for output on the network ports 1 and
2. In the other direction, the cable combines the optical signals received on each
client port into an multiplex for output on the client port.
The multimode y-cable can be used either the Transmit (Tx) or Receive (Rx)
direction at either end of a fiber span.
The 62.5 µm multimode y-cable is available in four variants:
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
J/SM/4CS-#C1270-#C1330/LC/0400
The J/SM/4CS-#C1270-#C1330/LC/0400 is a 5-port unidirectional CWDM
channel splitter/combiner for channels #C1270 - #C1330. It is designed for
connecting a 40G transceiver CFP (LR4) to four 10G transceiver SFP+
interfaces, enabling transmission of 40G traffic over 10G channels.
Each port of the J/SM/4CS-#C1270-#C1330/LC/0400 is terminated with a single
mode LC connector. The ports associated with the four separate wavelengths
are the network ports, while the port associated with the aggregate 40G signal is
the client port. The corresponding wavelength is printed on each network port.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Optical Amplifiers
This chapter describes the optical amplifiers of the FSP 3000R7.
The descriptions of the discontinued optical amplifiers can be found in a former
version of the FSP 3000R7 Module and System Specification.
The following sections are provided:
“EDFA-C-D17-GC” on p. 654
“EDFA-L-D17-GC” on p. 657
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
“EDFA-C-S20-GCB-DM” on p. 660
“EDFA-C-D20-VGC-DM” on p. 663
“EDFA-C-D20-VLGC-DM” on p. 667
“EDFA-C-S26-VGC-DM” on p. 671
“EDFA-C-S26-VGCB-DM” on p. 675
“RAMAN-C10” on p. 679
“2RAMAN-C15-LL” on p. 684
“AMP-S20H-C15” on p. 692
“AMP-S20L-C15” on p. 699
“EDFA-S20H” on p. 706
“EDFA-S20L” on p. 711
“2EDFA-S20L-S10L” on p. 716
EDFA-C-D17-GC
The EDFA-C-D17-GC is a gain-controlled, double-stage Erbium-doped fiber
amplifier supporting amplification of up to 80 channels in the C band. The first
gain block works as preamplifier, the second as booster amplifier. The midstage
access allows to connect a dispersion compensation module without effecting
the line budget. The gain and transient controller regulates the pump laser to
stabilize the ratio between output and input power, i.e. the gain of the
amplification stage. The EDFA-C-D17-GC can be used as preamplifier, booster
or inline amplifier.
Table 1142 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
MTBF at 25°C ambient temperature 512,558 h
Typ. power consumption 16 W
Max. power consumption 26 W
Maximum RAM consumption on 56 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P
This table provides information about fault monitoring of the module in general.
This table shows information about fault monitoring of the amplifier ports.
This table shows information about fault monitoring of the midstage ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Gain block temperature (current value)
EDFA-L-D17-GC
The EDFA-L-D17-GC is a gain-controlled, double-stage Erbium-doped fiber
amplifier supporting amplification of up to 40 channels in the L band. The first
gain block works as preamplifier, the second as booster amplifier. The midstage
access allows to connect a dispersion compensation module without effecting
the line budget. The gain and transient controller regulates the pump laser to
stabilize the ratio between output and input power, i.e. the gain of the
amplification stage. The EDFA-L-D17-GC can be used as preamplifier, booster
or inline amplifier.
Table 1152 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Gain flatness (1569.59 to 1570.42 2 dBpp
nm)
Noise figure 6.8 dB
Optical return loss -40 dB
Polarization dependent gain 0.5 dB
This table provides information about fault monitoring of the module in general.
This table shows information about fault monitoring of the amplifier ports.
This table shows information about fault monitoring of the midstage ports.
EDFA-C-S20-GCB-DM
The EDFA-C-S20-GCB-DM is a fixed gain-controlled, single-stage, dual
monitoring Erbium-doped fiber booster amplifier to amplify up to 80 channels in
the C band. The gain and transient controller regulates the pump laser to
stabilize the ratio between output and input power, i.e. the gain of the
amplification stage. The power level of the incoming weak signal and outgoing
amplified signal may be monitored.
Table 1162 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Typ. power consumption 11 W
Max. power consumption 22 W
Maximum RAM consumption on 44 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
EDFA-C-D20-VGC-DM
The EDFA-C-D20-VGC-DM is a gain-controlled, double-stage, dual monitoring
Erbium-doped fiber amplifier with a variable gain supporting amplification of up
to 80 channels in the C band.
The first gain block works as preamplifier, the second as booster amplifier. The
midstage access allows to insert a dispersion compensation module without
effecting the line budget. A variable optical attenuator (VOA) at the midstage
access controls and suitably adjusts attenuation of up to 16 dB depending on
whether a dispersion compensating module or a jumper connects the two gain
blocks. The gain and transient controller regulates the pump laser to stabilize
the ratio between output and input power, i.e. the gain of the amplification stage.
The power level of the incoming weak signal and outgoing amplified signal may
be monitored.
The EDFA-C-D20-VGC-DM can be used as preamplifier, booster or inline
amplifier.
Table 1168 provides general information about the module and its environment.
Height 5 HU
Weight 565 g (1.2 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 630,926 h
Typ. power consumption 15 W
Max. power consumption 26 W
Maximum RAM consumption on 61 Kbytes
NCU
Slot positions SH9HU: 3...18
SH7HU, SH7HU-R: 3...18
SH1HU: 1, 2
NCU types NCU, NCU-II, NCU-II-P
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
0 dB ... 12 dB at Gain = 23 dB
0 dB ... 16 dB at Gain = 19 dB
Tilt set -1dB tilt (default) allowed for entire gain set
range
0 dB tilt allowed for gain <33.4 dB (0 dB tilt
set is possible only when DCM loss has
1.5 dB of margin for a given gain setting)
-0.5 dB tilt allowed for gain <34.2 dB
-1.5 dB tilt allowed for gain >19.8 dB
-2.0 dB tilt allowed for gain >20.6 dB
Default tilt setting -1 dB
Tilt accuracy +/- 0.3 dB for gain set range 19 dB ... 32 dB
+/- 0.5 dB for gain set range > 32 dB
Max. total optical output power < 21.3 dBm
Gain flatness (over all 1.5 dBpp for gain set range 19 dB ... 32 dB
conditions) 2 dBpp for gain set range > 32 dB
Noise figure 5.2 dB at Gain > 30 dB
5.5 dB at Gain = 26 dB
7 dB at Gain = 23 dB
10 dB at Gain = 19 dB
Transient Response Transients up to 15 dB per 100 µs are
compressed to <2.0dB with setting time of
<1ms.
Optical input return loss -40 dB
This table provides information about fault monitoring of the module in general.
This table shows information about fault monitoring of the amplifier ports.
This table shows information about fault monitoring of the midstage ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Attenuation between stages (current value);
Attenuation of VOA (current value);
Laser bias current (current value);
Laser temperature (current value);
EDFA-C-D20-VLGC-DM
The EDFA-C-D20-VLGC-DM is a gain-controlled, double-stage, dual monitoring
Erbium-doped fiber amplifier with a variable low gain supporting amplification of
up to 80 channels in the C band.
The first gain block works as preamplifier, the second as booster amplifier. The
midstage access allows to connect to a dispersion compensation module
without affecting the line power budget. A variable optical attenuator (VOA) prior
to the midstage access controls and adjusts the attenuation to change the gain
to the desired level between 12 and 27 dB subject to constraints imposed by the
midstage loss. The maximum gain of the dual stage amplifier with DCM in the
midstage is equal to 27 dB - DCM loss. The gain and transient controller
regulates the pump laser to stabilize the ratio between output and input power,
i.e. the amplifier operates in gain locked mode with fast transient suppression.
The power level of the incoming weak signal and outgoing amplified signal
could be monitored in service with internal photodiodes as well as externally
with monitoring equipment connected to the tap ports.
The EDFA-C-D20-VLGC-DM can be used as preamplifier, booster or inline
amplifier.
Table 1178 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Gain set range 12 ... 27 dB
Midstage loss 0 dB at Gain = 27 dB
0 ... 3 dB at Gain = 24 dB
0 ... 6 dB at Gain = 21 dB
0 ... 9 dB at Gain = 18 dB
0 ... 12 dB at Gain = 15 dB
0 ... 15 dB at Gain = 12 dB
Tilt set -0.5 dB tilt (default) allowed for entire gain
set range
0 dB tilt allowed for gain <26.2 dB
-1.0 dB tilt allowed for gain >12.8 dB
-1.5 dB tilt allowed for gain >13.6 dB
Default tilt setting -0.5 dB
Tilt accuracy +/- 0.3 dB for gain set range
12 dB ... 24 dB
+/- 0.5 dB for gain set range
> 24 dB
Max. total optical output power 20.5 dBm
Gain flatness 1.5 dBpp for gain set range 12 dB ... 24 dB
(over all conditions) 2 dBpp for gain set range > 24 dB
This table provides information about fault monitoring of the module in general.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table shows information about fault monitoring of the amplifier ports.
This table shows information about fault monitoring of the midstage ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Defect seconds (DS)
EDFA-C-S26-VGC-DM
The EDFA-C-S26-VGC-DM is a variable gain-controlled, single-stage, high
output power, dual monitoring Erbium-doped fiber amplifier. The amplifier
module is capable of amplifying up to 81 channels in the C-band group.
A variable optical attenuator (VOA) at the input amplification stage controls the
gain and adjusts launch power.
Due to the high output power capabilities the network fiber must be connected
for the amplifier to function at full power. Pilot signals are used to verify the
connectivity of the network fiber. Pilots consist of either the OSC or Raman
pumps. If the EDFA-C-S26-VGC-DM is connected to another
EDFA-C-S26-VGC-DM, the OSC is the pilot signal. For this, the ALS of the
OSCM-PN has to be disabled. If the EDFA-C-S26-VGC-DM is connected to a
RAMAN-C10, the Raman pump is the pilot signal. The pilot signal must be
detected for the EDFA-C-S26-VGC-DM to operate at full output power.
The EDFA-C-S26-VGC-DM can be used as a booster amplifier or a
pre-amplifier for in-line amplifier configurations.
PS
Table 1188 provides general information about the module and its environment.
This table provides the optical specification directed from upgrade port (U-R) to
network port (N-T).
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
+13 dBm at 13.5 dB gain setting
Max. total output power +26dBm, +/- 0.5 dBm (APR off)
+10 dBm (APR on)
Typ. total output power +26.5 dBm
Data signal LOS set -23 dBm
clear -21 dBm
Gain set range 13.5 dB ... 23.5 dB
Fixed gain tilt -2 dB
Gain ripple +/-1 dB with respect to -2 dB gain tilt
OSC pilot signal threshold for APR < -34 dBm
on (pump lasers off)
OSC pilot signal threshold for APR > -32 dBm
off (pump lasers on again)
Max. OSC pilot input signal -10 dBm
Raman pump pilot threshold for APR < -35 dBm
on (pump lasers off)
Raman pump pilot threshold for APR > -33 dBm
off (pump lasers on again)
Noise figure 8 dB at 23.5 dB gain setting
Optical return loss > 40 dB
Polarization dependent gain < 0.5 dB
Transient Response Transients up to 15 dB per 100 µs
are compressed to <4.0dB with
setting time of <1ms.
This table provides the optical specification directed from network port (N-R) to
upgrade port (U-T).
The following table contains the optical specification of the client ports.
This table provides information about fault monitoring of the module in general.
This table shows information about fault monitoring of the network ports.
This table shows information about fault monitoring of the upgrade ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table provides information about performance monitoring of the
module in general.
This table shows information about performance monitoring from upgrade port
to network port.
EDFA-C-S26-VGCB-DM
The EDFA-C-S26-VGCB-DM is a variable gain-controlled, single-stage, high
output power, dual monitoring Erbium-doped fiber booster amplifier. The
amplifier module is capable of amplifying up to 81 channels in the C-band
group.
A variable optical attenuator (VOA) at the input amplification stage controls the
gain and adjusts launch power.
Due to the high output power capabilities the network fiber must be connected
for the amplifier to function at full power. Pilot signals are used to verify the
connectivity of the network fiber. Pilots consist of either the OSC or Raman
pumps. If the EDFA-C-S26-VGCB-DM is connected to another
EDFA-C-S26-VGCB-DM, the OSC is the pilot signal. For this, the ALS of the
OSCM-PN has to be disabled. If the EDFA-C-S26-VGCB-DM is connected to a
RAMAN-C10, the Raman pump is the pilot signal. The pilot signal must be
detected for the EDFA-C-S26-VGCB-DM to operate at full output power.
The EDFA-C-S26-VGCB-DM can be used as a booster amplifier or a
pre-amplifier for in-line amplifier configurations.
PS
Table 1188 provides general information about the module and its environment.
This table provides the optical specification directed from upgrade port (U-R) to
network port (N-T).
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Max. total input power +3 dBm at 23 dB gain setting
+13 dBm at 13 dB gain setting
Min. total input power -20 dBm at 23 dB gain setting
Max. total output power +26 dBm, +/- 0.5 dBm (APR off)
+10 dBm (APR on)
Typ. total output power +26.5 dBm
Data signal LOS set -23 dBm
clear -21 dBm
Gain set range 13.5 dB ... 23.5 dB
Fixed gain tilt -2 dB
Gain ripple +/-1 dB with respect to -2 dB gain tilt
OSC pilot signal threshold for APR < -38 dBm (pump lasers off)
on < -40 dBm (pump lasers on)
OSC pilot signal threshold for APR > -36 dBm (pump lasers off)
off > -38 dBm (pump lasers on again)
Max. OSC pilot input signal -10 dBm
Raman pump pilot threshold for APR < -35 dBm
on (pump lasers off)
Raman pump pilot threshold for APR > -33 dBm
off (pump lasers on again)
Noise figure 8 dB at 23.5 dB gain setting
Optical return loss > 40 dB
Polarization dependent gain < 0.5 dB
This table provides the optical specification directed from network port (N-R) to
upgrade port (U-T).
The following table contains the optical specification of the client ports.
This table provides information about fault monitoring of the module in general.
This table shows information about fault monitoring of the network ports.
This table shows information about fault monitoring of the upgrade ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table provides information about performance monitoring of the
module in general.
This table shows information about performance monitoring from upgrade port
to network port.
RAMAN-C10
The RAMAN-C10 is a fiber Raman amplifier with constant pump power used for
backward distributed Raman amplification in DWDM networks. It is capable of
amplifying up to 81 channels in the C band.
The power level of the outgoing Raman amplified signal may be monitored. The
RAMAN-C10 can be used as pre-amplifier stage in front of an EDFA module
(inline, pre- or booster amplifier) to increase its input power. In combination with
EDFA-C-D20-VGC-DM, the Raman amplifier is capable for up to 50 dB span
loss.
Due to the high output power capabilities, the network fiber must be connected
for the amplifier to function at full power. The 1528.77 nm OSC signal from the
OSCM-PN is used as a pilot signal to verify the integrity of the network fiber. For
this, the ALS of the OSCM-PN has to be disabled.
PS
Table 1210 provides general information about the module and its environment.
MON-R
Tap coupler Tap
Transmission fiber
Pump
OSC drop filter Tap
power N-R U-T
GFF
Data signals + Raman
OSC signal 1450/1550 nm Tap
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
PD4 amplified
from the network WDM
Tap data signals
C-T Signal power
monitor
OSC signal OSC
PD5 monitor
C-R
The following table contains the optical specification of the upgrade ports.
The following table contains the optical specification of the client ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Passband MON-T 1529 nm ... 1562 nm
MON-T coupling ratio 1% of N-T
This table provides information about fault monitoring of the module in general.
This table shows information about fault monitoring of the network ports.
This table shows information about fault monitoring of the upgrade ports.
Fix threshold crossing alerts for OSC optical power Rx (current, low, mean,
OPT too high/too low available) high);
Defect seconds (DS)
2RAMAN-C15-LL
The 2RAMAN-C15-LL is a dual Raman amplifier module optimized to be used in
low latency networks. It offers minimum ASE noise and maximum flatness for
extended links. Each Raman is designed to operate over spans supporting 81
C band channels with span budgets of 15 dB to 30 dB. The Raman operates
without EDFA booster amplifiers. Each module contains a forward (FWD) and a
backward (BWD) facing Raman amplifier. The gain on each of the two amplifiers
can be set independently from 7 dB to 15 dB.
The module is designed to operate with both Raman amplifiers turned on. The
forward Raman cannot be used without the backward Raman because it will not
turn on without having the backward Raman running on the same span. The
backward Raman does not need the forward Raman, but it does need to receive
the 1528.77 nm OSC signal, which is added to the built-in OSC filter at the
upstream forward Raman amp C-R port. The ALS of the OSCM-PN has to be
disabled.
The module occupies two slots in a FSP 3000R7 7HU and 9HU shelves.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
The following table provides general information about the module and its
environment.
Backward RAMAN
Output
ASE
PD
PD
Network Rx Upgrade Tx
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
N-R U-T
Pump OSC
PD PD
Client Tx
Raman Pumps C-T
Client Rx
C-R
OSC
PD
Pump
PD
ASE
PD
Raman Pumps Input
PD
Forward RAMAN
Tap
Mon-T
The following table contains the optical specification of the upgrade ports.
This table provides the optical specification of the network ports for the BWD
Raman.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Supported transmission fiber type G.652 (SMF28, Allwave), G.655
(TW-RS, Teralight, TW-Reach),
ULL (Ultra-Low Loss) fiber
Min. gain for all supported fiber types 7 dB
Max. gain ranges for G.652 (SMF28, 9.5 dB to 14.5 dB1
Allwave), ULL (Ultra-Low Loss) fiber
Max. gain for G.655 (TW-RS, Teralight, 15 dB1
TW-Reach)
Min. data signal total input power at N-R -36 dBm
(without ASE and RAMAN gain)
Max. data signal total input power at N-R -3 dBm at 15 dB gain
(pump off) (Input + Gain < 12 dBm)
Min. OSC input power at N-R (pump off) -38 dBm
Max. OSC input power at N-R (pump off) -19 dBm
Data signal LOS (pump off) raise at -39 dBm
clear at -37 dBm
OSC input LOS (pump off) raise at -40 dBm
clear at -39 dBm
Max total output pump power at N-R 30 dBm2
Net OSC gain 7 dB... 15 dB
Gain flatness < 1.5 dBpp
Tilt Setable for: -2.0, -1.5, -1.0 dB
(default = -1.0 dB)
Effective noise figure < -1.0 dB at 15 dB gain
Optical return loss > 40 dB
Polarization dependent gain < 0.5 dB
This table provides the optical specification of the network ports for the FWD
Raman.
The following table contains the optical specification of the client ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Adjacent isolation N-R to C-R > 32 dB
This table provides information about fault monitoring of the module in general.
This table shows information about fault monitoring of the network ports.
This table shows information about fault monitoring of the upgrade ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table shows information about performance monitoring of the network
ports.
This table shows information about performance monitoring of the BWD Raman
amplifier.
This table shows information about performance monitoring of the FWD Raman
amplifier.
AMP-S20H-C15
The AMP-S20H-C15 module is an integrated high gain EDFA and BWD Raman
amplifier pair designed to operate over spans supporting 96 C band channels. It
offers minimum ASE noise and maximum flatness for moderate links. If the span
is relatively short or a pre-amp/post amp is needed, the Raman amplifier is not
needed. The EDFA may be used independently.
Integration of two amplifiers on the same module reduces the number of individ-
ual amplifier types needed. Usage of the EDFA or Raman amplifiers is depen-
dent on the application. The module allows usage of the EDFA amplifier alone,
or both the EDFA and BWD Raman. If the BWD Raman is used, the EDFA must
also be used because when the EDFA pumps are turned off the signal path is
severely attenuated. If the EDFA is used alone, there is a 2 dB loss through the
BWD Raman without the pumps on.
The amplifier also has improved transient control, allowing for better regulation
of variations in channel amplitudes.
Due to the high output power capabilities, the network fiber must be connected
for the amplifier to function at full power. The 1528.77 nm OSC signal from the
OSCM-PN is used as a pilot signal to verify the integrity of the network fiber. For
this, the ALS of the OSCM-PN has to be disabled.
The module occupies two slots in a FSP 3000R7 7HU and 9HU shelves.
The AMP-S20H-C15 is intended for special applications. This
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
amplifier type must not be used in VSM protected configurations. For
PS
Table 1239 provides general information about the module and its environment.
OSC Directon
OSC OSC
R PD
Level Set
C T OSC
PD
OSC Directon
Mon
This table provides the optical specification of the network ports for the BWD
Raman.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Passband 1528.5 nm ... 1568.5 nm
Supported transmission fiber type G.652 (SMF28, Allwave), G.655
(LEAF, TW-RS, Teralight,
TW-Reach), ULL (Ultra-Low
Loss) fiber
Standard gain range for all fiber types. 9 dB to 15 dB2
Extended gain range 9 dB to 18 dB3
Min. data signal total input power at N-R -36 dBm
(without ASE and RAMAN gain)
Max. data signal total input power at N-R 0 dBm at gain = 15 dB,
(pump off) 3 dBm at gain = 12 dB,
6 dBm at gain = 9 dB
Min. OSC input power at N-R -38 dBm
Max. OSC input power at N-R (pump off) -19 dBm
Data signal LOS raise at -38 dBm
clear at -36 dBm
OSC input LOS raise at -39 dBm
clear at -38 dBm
Max total output pump power at N-R 30 dBm1
Gain flatness < 1.5 dBpp
Tilt Setable for: -2.0, -1.5, -1.0 dB
(default = -1.0 dB)
Effective noise figure < -1.0 dB at 15 dB gain
Insertion loss N-R to U-T 2 dB
Optical return loss > 40 dB
This table provides the optical specification for the EDFA directed from upgrade
port (U-R) to network port (N-T).
The following table contains the optical specification of the client port.
This table provides information about fault monitoring of the module in general.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Board temperature too high
This table shows information about fault monitoring of the network port.
This table shows information about fault monitoring of the upgrade port.
This table shows information about performance monitoring of the network port.
This table shows information about performance monitoring of the BWD Raman
amplifier.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Defect seconds (DS)
Back Reflection (current, low, mean, high);
Back Reflection TCA (high, low)
This table shows information about performance monitoring of the FWD Raman
amplifier.
AMP-S20L-C15
The AMP-S20L-C15 module is an integrated low gain EDFA and BWD Raman
amplifier pair designed to operate over spans supporting 96 C band channels. It
offers minimum ASE noise and maximum flatness for moderate links. If the span
is relatively short or a pre-amp/post amp is needed, the Raman amplifier is not
needed. The EDFA may be used independently.
Integration of two amplifiers on the same module reduces the number of individ-
ual amplifier types needed. Usage of the EDFA or Raman amplifiers is depen-
dent on the application. The module allows usage of the EDFA amplifier alone,
or both the EDFA and BWD Raman. If the BWD Raman is used, the EDFA must
also be used because when the EDFA pumps are turned off the signal path is
severely attenuated. If the EDFA is used alone, there is a 2 dB loss through the
BWD Raman without the pumps on.
The amplifier also has improved transient control, allowing for better regulation
of variations in channel amplitudes.
Due to the high output power capabilities, the network fiber must be connected
for the amplifier to function at full power. The 1528.77 nm OSC signal from the
OSCM-PN is used as a pilot signal to verify the integrity of the network fiber. For
this, the ALS of the OSCM-PN has to be disabled.
The module occupies two slots in a FSP 3000R7 7HU and 9HU shelves.
ADVA Optical Networking does not support using the AMP-S20L-C15
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 1255 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 1256: Ports
Optical connector type LC
Fiber type G.652
N-R Network Rx (BWD Raman Laser out)
U-T Upgrade Tx (BWD Raman amplified signal out)
MON-R Upgrade Tx Tap (BWD Raman amplified signal
monitor)
C-T Client Tx (OSC drop)
U-R Upgrade Rx (EDFA input)
N-T Network Tx (EDFA output)
MON-T Network Tx Tap (monitor for EDFA input)
C-R Client Rx (OSC add)
OSC Directon
OSC OSC
R PD
Level Set
C T OSC
PD
OSC Directon
This table provides the optical specification of the network ports for the BWD
Raman.
This table provides the optical specification for the EDFA directed from upgrade
port (U-R) to network port (N-T).
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Max. total output power 21 dBm (OPT power limit will attempt
to regulate at 20.8 dBm)
Data signal LOS set -28 dBm
clear -28 dBm
Gain set range 4 dB ... 13 dB
Fixed gain tilt 0 dB
Gain ripple +/-1 dB
Output VOA Level Set Range 0 dB to 12 dB
Output VOA Level Set Accuracy +/-0.5 dB
Noise figure 6.5 dB at gain = 13 dB
7.5 dB at gain = 10 dB
10 dB at gain = 7 dB
13 dB at gain = 4 dB
Optical return loss > 40 dB
Polarization dependent gain < 0.5 dB
Transient Response Transients up to 15 dB per 100 µs
are compressed to <2.5dB with
setting time of <1ms.
Latency U-R to N-T < 250 ns
OPR/OPT accuracy +/- 1 dB
The following table contains the optical specification of the client port.
This table provides information about fault monitoring of the module in general.
This table shows information about fault monitoring of the network port.
This table shows information about fault monitoring of the upgrade port.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Transmit Power is Limited;
Auto Shut down due to high pump temperature;
Auto Shut down due to inability to regulate exces-
sive OPT;
Noise reduction APR applied due to LOS;
EDFA Attenuator Fail;
This table shows information about performance monitoring of the network port.
This table shows information about performance monitoring of the BWD Raman
amplifier.
This table shows information about performance monitoring of the EDFA ampli-
fier.
EDFA-S20H
The EDFA-S20H module is an integrated high gain EDFA designed to operate
over spans supporting 96 C band channels. It is primarily used with the 100G
channel cards that apply electronic dispersion compensation. The amplifier has
an output VOA that allows optimization of the amplifier gain setting and launch
power. The amplifier gain setting is selected to minimize noise while the launch
power is selected to minimize distortions in the fiber. The module contains OSC
filters that remove the need for an additional external OSC filter module there-
fore reducing equipment requirements. The amplifier also has improved gain
and transient control, allowing for better regulation of variations in channel
amplitudes. An optional OSC VOA is available and is used to set the optimal
OSC launch power based on the span loss.
The EDFA-S20H can be used as a booster amplifier, pre-amplifier or in-line
amplifier. Fiber Detection is available on the amplifier U ports.
This table provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 376,206 h
Typ. power consumption 25 W
Max. power consumption 30 W
Slot positions SH9HU: 3...18
SH1HU: 1 and 2
SH7HU, SH7HU-R: 1...20
NCU types NCU-II, NCU-II-P
MON-T
OS C FI L
U -R N -T
Stage 1 Stage 2
Optojack
Fiber
Mon
Det
UPGRADE NETWORK
OSC VOA
OSC FIL
U -T N -R
MON- R
OSC
C-R C-T 1528 nm
CLIENT
This table provides the optical specification of the network ports for the passive
path from the N-R to U-T ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table provides the optical specification for the EDFA from the U-R to N-T
ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Insertion loss C-T to N-T 1 dB
Return loss C-T > 40 dB
Return loss C-R > 40 dB
This table provides information about fault monitoring of the module in general.
This table shows information about fault monitoring of the network ports.
This table shows information about fault monitoring of the upgrade ports.
This table shows information about performance monitoring of the EDFA ampli-
fier.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
EDFA
EDFA Attenuator current attenuation applied by
VOA
EDFA-S20L
The EDFA-S20L module is an integrated low gain EDFA designed to operate
over spans supporting 96 C band channels. It is primarily used with the 100G
channel cards that apply electronic dispersion compensation. The amplifier has
an output VOA that allows optimization of the amplifier gain setting and launch
power. The amplifier gain setting is selected to minimize noise while the launch
power is selected to minimize distortions in the fiber. The module contains OSC
filters that remove the need for an additional external OSC filter module there-
fore reducing equipment requirements. The amplifier also has improved gain
and transient control, allowing for better regulation of variations in channel
amplitudes. An optional OSC VOA is available and is used to set the optimal
OSC launch power based on the span loss.
The EDFA-S20L can be used as a booster amplifier, pre-amplifier or in-line
amplifier. Fiber Detection is available on the amplifier U ports.
This table provides general information about the module and its environment.
MON-T
OS C FI L
U -R N -T
Stage 1 Stage 2
Optojack
Fiber
Mon
Det
UPGRADE NETWORK
OSC VOA
OSC FIL
U -T N -R
MON- R
OSC
C-R C-T 1528 nm
CLIENT
This table provides the optical specification of the network ports for the passive
path from the N-R to U-T ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 1287: Optical Specification N-R to U-T
Passband 1528.5 nm ... 1568.5 nm
Insertion loss N-R to U-T < 2 dB
This table provides the optical specification for the EDFA from the U-R to N-T
ports.
This table provides information about fault monitoring of the module in general.
This table shows information about fault monitoring of the network ports.
This table shows information about fault monitoring of the upgrade ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
This table provides information about performance monitoring of the module in
general.
This table shows information about performance monitoring of the EDFA ampli-
fier.
EDFA
EDFA Attenuator current attenuation applied by
VOA
2EDFA-S20L-S10L
The 2EDFA-S20L-S10L module is a dual EDFA designed to be an EDFA only
alternative to the EDFA/RAMAN amplifier AMP-S20x in 9ROADM applications
where use of a Raman amplifier is not desired. The amplifier gain and output
power are similar to the AMP-S20x. The 2EDFA-S20L-S10L is primarily used
with the 100G channel cards that apply electronic dispersion compensation.The
amplifier is designed to operate over spans supporting 96 C band channels. The
amplifier has an output VOA that allows optimization of the amplifier gain setting
and launch power. The amplifier gain setting is selected to minimize noise while
the launch power is selected to minimize distortions in the fiber. The module
contains OSC filters that remove the need for an additional external OSC filter
module therefore reducing equipment requirements. The amplifier also has
improved gain and transient control, allowing for better regulation of variations in
channel amplitudes. An OSC VOA is available and is used to set the optimal
OSC launch power based on the span loss.
The 2EDFA-S20L-S10L can be used as a booster amplifier, pre-amplifier or
in-line amplifier. Fiber Detection is available on the amplifier U ports.
This table provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Width 8 HP
Height 5 HU
Max. weight 1335 g (2.94 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IP20. Use in a pollution degree 2
IEC 60529 environment and indoor controlled
office environments only.
MTBF at 25°C ambient temperature 275,868 h
Typ. power consumption 25 W
Max. power consumption 50 W
Slot positions SH9HU: 3...17
SH1HU: 1
SH7HU, SH7HU-R: 3...17
NCU types NCU-II, NCU-II-P
2 EDFA-S20L-S10L
C- Band Signals
MON -T
OSC FIL
U-R N-T
Output VOA
Booster Amplifier
Fiber Detection
Link Direction S20 OSC
OSC VOA
1528nm
Fiber
Det
UPGRADE C-R
NETWORK
CLIENT
C- T
Fiber Detection
Link Direction
OSC
1528nm
OSC FIL
U-T N-R
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Pre- Amplifier
S10
MON-R
C- Band Signals
This table provides the optical specification for the EDFA from the N-R to U-T
ports.
This table provides the optical specification for the EDFA from the U-R to N-T
ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Noise figure (default tilt) @ Gain = 21 dB: 5.8 dB
@ Gain = 18 dB: 6.0 dB
@ Gain = 15 dB: 8 dB
@ Gain = 11 dB: 15 dB
Optical return loss > 40 dB
Polarization dependent gain < 0.5 dB
Transient Response Transients up to 15 dB per 100 µs are
compressed to < 2.5 dB with settling
time of <1ms.
Latency U-R to N-T 250ns
OPR/OPT accuracy +/- 0.5 dB
This table provides information about fault monitoring of the module in general.
This table shows information about fault monitoring of the network ports.
This table shows information about fault monitoring of the upgrade ports.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
and high);
OSC Power Tx/Rx
This table shows information about performance monitoring of the EDFA ampli-
fier.
This table shows information about performance monitoring for U-port PTP fiber
detection.
Dispersion Compensation
Modules
The following chapter describes the dispersion compensation modules of the
FSP 3000R7.
The descriptions of the discontinued dispersion compensation modules can be
found in a former version of the FSP 3000R7 Module and System Specification.
The following sections are provided:
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
“DCF-M/xxx/SSMF” on p. 724
“DCG-M/xxx/SSMF” on p. 727
“DCG50-M/xxx/SSMF” on p. 729
“DCG-M/xxx/TWRS” on p. 731
“DCG50-M/xxx/TWRS” on p. 733
“DCF1HU-P Shelf” on p. 735
DCF-M/xxx/SSMF
The DCF-M/xxx/SSMF is a managed Dispersion Compensation Module. It can
be used for the compensation of dispersion of Standard Single-Mode Fiber
according to G.652.
The following variants are available:
• DCF-M/010/SSMF
• DCF-M/020/SSMF
• DCF-M/030/SSMF
• DCF-M/040/SSMF
• DCF-M/050/SSMF
• DCF-M/060/SSMF
• DCF-M/070/SSMF
• DCF-M/080/SSMF
• DCF-M/090/SSMF
• DCF-M/100/SSMF
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
First release 7.1 (010, 020, 040, 060, 080, 100)
9.1 (030, 050, 070, 090)
Width 8 HP
Height 5 HU
Weight 1.2 kg (2.6 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection according to IEC IP20. Use in a pollution degree 2
60529 environment and indoor controlled
office environments only.
Power consumption 1.2 W
Maximum RAM consumption on NCU 25 Kbytes
MTBF at 25°C ambient temperature 54,285,711 h
Slot positions SH9HU: 3...17
SH7HU, SH7HU-R: 3...17
SH1HU: 1
Max. latency
DCF-M/010/SSMF 15 µs
DCF-M/020/SSMF 20 µs
DCF-M/030/SSMF 25 µs
DCF-M/040/SSMF 30 µs
DCF-M/050/SSMF 35 µs
DCF-M/060/SSMF 40 µs
DCF-M/070/SSMF 45 µs
DCF-M/080/SSMF 50 µs
DCF-M/090/SSMF 55 µs
DCF-M/100/SSMF 60 µs
DCF-M/010/SSMF 2.5 dB
DCF-M/020/SSMF 3 dB
DCF-M/030/SSMF 3.6 dB
DCF-M/040/SSMF 4.3 dB
DCF-M/050/SSMF 4.8 dB
DCF-M/060/SSMF 5.4 dB
DCF-M/070/SSMF 6.1 dB
DCF-M/080/SSMF 6.7 dB
DCF-M/090/SSMF 7.3 dB
DCF-M/100/SSMF 8.7 dB
Insertion loss typ. value
DCF-M/010/SSMF 1.65 dB
DCF-M/020/SSMF 2.15 dB
DCF-M/030/SSMF 2.51 dB
DCF-M/040/SSMF 3.2 dB
DCF-M/050/SSMF 3.65 dB
DCF-M/060/SSMF 4.12 dB
DCF-M/070/SSMF 4.74 dB
DCF-M/080/SSMF 5.43 dB
DCF-M/090/SSMF 6.25 dB
DCF-M/100/SSMF 7.1 dB
Table 1319 provides information about the chromatic dispersion of the modules.
Table 1319: Chromatic Dispersion
CD min CD max CD min CD max CD min CD max
at 1530 nm, in ps/nm at 1562 nm, in ps/nm at 1602 nm, in ps/nm
DCF-M/010/SSMF -168 -152 -187 -173 -210 -191
DCF-M/020/SSMF -336 -304 -373 -347 -419 -381
DCF-M/030/SSMF -479 -456 -547 -520 -608 -572
DCF-M/040/SSMF -672 -608 -746 -693 -838 -762
DCF-M/050/SSMF -799 -760 -911 -867 -1014 -953
DCF-M/060/SSMF -1008 -912 -1118 -1040 -1256 -1143
DCF-M/070/SSMF -1118 -1064 -1275 -1213 -1419 -1334
DCF-M/080/SSMF -1344 -1216 -1492 -1387 -1676 -1524
DCF-M/090/SSMF -1438 -1368 -1640 -1560 -1825 -1715
DCF-M/100/SSMF -1680 -1520 -1864 -1733 -2094 -1905
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
DCG-M/xxx/SSMF
The Fiber-Bragg-Gratings Dispersion Compensation Module (DCG-M) can be
used for dispersion compensation of C-band channels only. It is a managed
module which must not be used on any other fiber type than Standard Single
Mode Fiber according to G.652.
The following variants are available:
• DCG-M/060/SSMF
• DCG-M/080/SSMF
• DCG-M/100/SSMF
Table 1320 provides general information about the module and its environment.
Table 1323 provides information about the chromatic dispersion of the modules.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
DCG50-M/xxx/SSMF
The DCG50-M/xxx/SSMF is a Fiber-Bragg-Grating dispersion compensation
module. The module is intended for dispersion compensation of C-band
channels in a 50 GHz channel grid of the FSP 3000R7 DWDM transmission
system.
It is a managed module which must not be used on any other fiber type than
Standard Single Mode Fiber according to G.652.
The following variants are available:
• DCG50-M/020/SSMF
• DCG50-M/040/SSMF
• DCG50-M/060/SSMF
• DCG50-M/080/SSMF
• DCG50-M/100/SSMF
Note
DCG50-M/040/SSMF or any combination of one of these DCGs
with DCG50-M/060/SSMF, DCG50-M/080/SSMF or
DCG50-M/100/SSMF in one link.
Table 1324 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Table 1327 provides information about the chromatic dispersion of the modules.
DCG-M/xxx/TWRS
The Fiber-Bragg-Gratings Dispersion Compensation Module (DCG-M) can be
used for dispersion compensation of C-band channels.
The Fiber Bragg Grating based dispersion compensation module for
TrueWave® RS Fiber is available in three module variants. Each module variant
compensates for a specific amount of dispersion.
The following variants are available:
• DCG-M/160/TWRS
• DCG-M/240/TWRS
• DCG-M/320/TWRS
Please use the Network Planner tool or contact Network Consultant
for assistance in case of using
PS
Table 1328 provides general information about the module and its environment.
Table 1331 provides information about the chromatic dispersion of the modules.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
DCG-M/320/TWRS -1204 -1046 -1683 -1462
DCG50-M/xxx/TWRS
The DCG50-M/xxx/TWRS is a Fiber-Bragg-Gratings dispersion compensation
module. The module can be used for dispersion compensation of C-band
channels in a 50 GHz channel grid of the FSP 3000R7 DWDM transmission
system.
The Fiber Bragg Grating based dispersion compensation module for
TrueWave® RS Fiber (according to G.655.C and G.655.D standards) is
available in three module variants. Each module variant compensates for a
specific amount of dispersion.
The following variants are available:
• DCG50-M/160/TWRS
• DCG50-M/240/TWRS
• DCG50-M/320/TWRS
Table 1332 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
DCF1HU-P Shelf
The DCF1HU-P Shelf is a Dispersion Compensation Shelf with one integrated
module. Chromatic dispersion is compensated for different length of fiber span
regardless of the wavelength (channel number).
The module-integrated DCF1HU-P Shelf is available with a compensation of
Standard Single-Mode Fiber (SSMF; G.652), a compensation of Large Effective
Area Fiber (LEAF; G.655), a compensation of True Wave Reduced Slope Fiber
(TWRS; G.655) and a compensation of MetroCor Fiber (MCOR; G.655).
The DCF1HU-P for dispersion compensation in applications with Standard
Single-Mode Fiber is available in the following variants:
• DCF1HU-P/10/SSMF
• DCF1HU-P/20/SSMF
• DCF1HU-P/40/SSMF
• DCF1HU-P/60/SSMF
• DCF1HU-P/80/SSMF
• DCF1HU-P/100/SSMF
• DCF1HU-P/120/SSMF
• DCF1HU-P/140/SSMF
• DCF1HU-P/160/SSMF
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• DCF1HU-P/180/SSMF
The DCF1HU-P for dispersion compensation in applications with Large
Effective Area Fiber is available in the following variants:
• DCF1HU-P/20/LEAF
• DCF1HU-P/40/LEAF
• DCF1HU-P/60/LEAF
• DCF1HU-P/80/LEAF
• DCF1HU-P/100/LEAF
• DCF1HU-P/120/LEAF
• DCF1HU-P/140/LEAF
• DCF1HU-P/160/LEAF
• DCF1HU-P/180/LEAF
The DCF1HU-P for dispersion compensation in applications with True Wave
Reduced Slope Fiber is available in the following variants:
• DCF1HU-P/20/TWRS
• DCF1HU-P/40/TWRS
• DCF1HU-P/80/TWRS
• DCF1HU-P/100/TWRS
• DCF1HU-P/120/TWRS
• DCF1HU-P/140/TWRS
• DCF1HU-P/160/TWRS
• DCF1HU-P/180/TWRS
The DCF1HU-P for dispersion compensation in applications with MetroCor
Fiber is available in the following variants:
• DCF1HU-P/010/MCOR
• DCF1HU-P/020/MCOR
• DCF1HU-P/030/MCOR
• DCF1HU-P/040/MCOR
• DCF1HU-P/050/MCOR
• DCF1HU-P/060/MCOR
Table 1335 provides general information about the module and its environment.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Height 44 mm (1.73”)
Depth (dimension without adaptor 267 mm (10.51”)
brackets)
Max. weight DCF1HU-P/x/SSMF 6.65 kg (14.7 lbs)
Max. weight DCF1HU-P/x/LEAF 4.07 kg (9 lbs)
Max. weight DCF1HU-P/x/TWRS 4.07 kg (9 lbs)
Max. weight DCF1HU-P/x/MCOR 4.7 kg (10.4 lbs)
Environmental conditions Telcordia SR-3580 level 3 (NEBS),
ETSI EN 300 019-1-3 Class 3.1
Degree of protection acc. to IEC 60529 IP20. Use in a pollution degree 2
environment and indoor controlled
office environments only.
Power consumption n.a.
MTBF at 25°C ambient temperature
DCF1HU-P/x/SSMF 71,428,574 h
DCF1HU-P/x/LEAF 71,428,574 h
DCF1HU-P/x/TWRS 71,428,574 h
DCF1HU-P/x/MCOR 212,765,957 h
DCF1HU-P/60/TWRS 75 µs
DCF1HU-P/80/TWRS 100 µs
DCF1HU-P/100/TWRS 125 µs
DCF1HU-P/120/TWRS 150 µs
DCF1HU-P/140/TWRS 175 µs
DCF1HU-P/160/TWRS 200 µs
DCF1HU-P/180/TWRS 225 µs
Max. latency DCF1HU-P/x/MCOR
DCF1HU-P/010/MCOR 20 µs
DCF1HU-P/020/MCOR 40 µs
DCF1HU-P/030/MCOR 60 µs
DCF1HU-P/040/MCOR 80 µs
DCF1HU-P/050/MCOR 100 µs
DCF1HU-P/060/MCOR 120 µs
The following table contains information about the optical connector type.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
DCF1HU-P/100/LEAF 100 km (3937000“) 8.8 dB
DCF1HU-P/120/LEAF 120 km (4724400“) 9.4 dB
DCF1HU-P/140/LEAF 140 km (5511800“) 10 dB
DCF1HU-P/160/LEAF 160 km (6299200“) 11 dB
DCF1HU-P/180/LEAF 180 km (7086600“) 12 dB
True Wave Reduced Slope Fibers Min. compensation Insertion loss
(TWRS) for TWRS max. value
DCF1HU-P/20/TWRS 20 km (787400”) 3.2 dB
DCF1HU-P/40/TWRS 40 km (1574800“) 3.7 dB
DCF1HU-P/60/TWRS 60 km (2362205”) 4.2 dB
DCF1HU-P/80/TWRS 80 km (3149600“) 4.8 dB
DCF1HU-P/100/TWRS 100 km (3937000“) 5.3 dB
DCF1HU-P/120/TWRS 120 km (4724400“) 5.9 dB
DCF1HU-P/140/TWRS 140 km (5511800“) 6.4 dB
DCF1HU-P/160/TWRS 160 km (6299200“) 6.9 dB
DCF1HU-P/180/TWRS 180 km (7086600“) 7.4 dB
MetroCor Fiber (MCOR) Min. compensation Insertion loss
for (MCOR) max. value
DCF1HU-P/010/MCOR 10 km (393700“) 2.3 dB
DCF1HU-P/020/MCOR 20 km (787400“) 3.0 dB
DCF1HU-P/030/MCOR 30 km (1181100“) 3.8 dB
DCF1HU-P/040/MCOR 40 km (1574800“) 4.5 dB
DCF1HU-P/050/MCOR 50 km (1968500“) 5.3 dB
DCF1HU-P/060/MCOR 60 km (2362200“) 6.1 dB
Table 1338 provides information about the chromatic dispersion for the
DCF1HU-P shelf variants with Standard Single-Mode Fiber (SSMF), Large
Effective Area Fiber (LEAF), and True Wave Reduced Slope Fiber (TWRS).
Table 1338: Chromatic Dispersion (CD) for the Shelves with SSMF, LEAF and
TWRS Fibers
CD at 1529nm CD at 1561 nm
[ps/nm] [ps/nm]
Minimum Maximum Minimum Maximum
DCF1HU-P/10/SSMF -162 -151 -182 -170
DCF1HU-P/20/SSMF -324 -301 -364 -341
DCF1HU-P/40/SSMF -647 -604 -728 -682
DCF1HU-P/60/SSMF -971 -906 -1091 -1023
DCF1HU-P/80/SSMF -1294 -1209 -1455 -1365
DCF1HU-P/100/SSMF -1616 -1509 -1815 -1705
DCF1HU-P/120/SSMF -1940 -1811 -2179 -2047
DCF1HU-P/140/SSMF -2263 -2113 -2542 -2388
DCF1HU-P/160/SSMF -2586 -2415 -2905 -2730
DCF1HU-P/180/SSMF -2909 -2717 -3268 -3070
Table 1339 provides information about the chromatic dispersion for the
DCF1HU-P shelf variants with MetroCor Fiber (MCOR).
Table 1339: Chromatic Dispersion (CD) for the Shelves with MCOR Fiber
CD at 1530 nm CD at 1562 nm
[ps/nm] [ps/nm]
Minimum Maximum Minimum Maximum
DCF1HU-P/010/MCOR 53 59 60 67
DCF1HU-P/020/MCOR 107 118 121 134
DCF1HU-P/030/MCOR 162 176 183 199
DCF1HU-P/040/MCOR 216 235 244 266
DCF1HU-P/050/MCOR 270 293 305 332
DCF1HU-P/060/MCOR 325 352 368 397
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Overview of Modules
This document contains tables with general information about channel modules
as well as their relationships to each other as an overview. An overview of
pluggable transceivers is also provided.
This chapter is divided up into the following sections:
“Client and Network Interfaces” on p. 743
“DWDM Modules - Channel Grid Support” on p. 746
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Opt. dispersion
No.Client Ports
Output
Release No.
load [ps/nm]
Output
Power Sensitivity Sensitivity
Power
Client Client Port Network
Network
Port [dBm] Port [dBm]
Port [dBm]
[dBm]
Opt. dispersion
Output
Release No.
load [ps/nm]
Output
Power Sensitivity Sensitivity
Power
Client Client Port Network
Network
Port [dBm] Port [dBm]
Port [dBm]
[dBm]
5TCE-PCTN-8GU+10GS-V#DC 11.1 5 SFP - - 1 Tun 4.0 to 6.0 -20.0 to -8.0 200 to 800
5TCE-PCTN-8GU+AES10GS-LN#DC -300 to
11.1 5 SFP - - 1 Tun -3.0 to 0.0 -14.0 to -1.0
300
5TCE-PCTN-8GU+AES10GS-V#DC 11.1 5 SFP - - 1 Tun 4.0 to 6.0 -20.0 to -8.0 200 to 800
5TCE-PCN-10GU+10G SFP/
12.3 5 - - 1 SFP+ - - -
SFP+
5TCE-PCN-10GU+AES10G SFP/
12.3 5 - - 1 SFP+ - - -
SFP+
10TCE-PCN-16GU+AES100G 12.3 10 SFP+ - - 1 CFP - - -
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Opt. dispersion
Output
Release No.
load [ps/nm]
Output
Power Sensitivity Sensitivity
Power
Client Client Port Network
Network
Port [dBm] Port [dBm]
Port [dBm]
[dBm]
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
10PCA-PCN-1G3+10G XFP XFP no n.a.
2WCA-PCN-10G XFP XFP no n.a.
4TCA-PCN-4GU+4G SFP SFP yes yes1
4TCA-PCN-4GUS+4G SFP SFP yes yes1
WCA-PCN-2G5U SFP SFP yes yes1, 2
WCE-PCN-100G CFP CFP no n.a.
WCE-PCN-100GB CFP CFP no n.a.
4WCE-PCN-16GFC XFP XFP no n.a.
5TCE-PCTN-10GU+10G-LN#DC yes yes no n.a.
5TCE-PCTN-10GU+10G-V#DC yes yes no n.a.
5TCE-PCTN-10GU+10G-V#DL no no no n.a.
5TCE-PCTN-10GU+AES10G-LN#DC yes yes no n.a.
5TCE-PCTN-10GU+AES10G-V#DC yes yes no n.a.
5TCE-PCTN-10GU+AES10G-V#DL no no no n.a.
5TCE-PCN-10GU+10G SFP+ SFP+ no n.a.
5TCE-PCN-10GU+AES10G SFP+ SFP+ no n.a.
5TCE-PCTN-8GU+10GS-LN#DC yes yes no n.a.
5TCE-PCTN-8GU+10GS-V#DC yes yes no n.a.
5TCE-PCTN-8GU+AES10GS-LN#DC yes yes no n.a.
5TCE-PCTN-8GU+AES10GS-V#DC yes yes no n.a.
10TCE-PCN-16GU+AES100G CFP CFP no n.a.
10TCE-PCN-10G+100G CFP CFP no n.a.
10TCE-PCN-10G+100G-GF CFP CFP no n.a.
1. except L band
2. Requires FWP-Version 8.16.0 or later and capability level 1.
WCE-PCN-100GB X X X X - X X
4WCE-PCN-16GFC X2 X1,2 X2 X1,2 - X1,2 X1,2
5TCE-PCTN-10GU-LN#DC X X X X - X X
5TCE-PCTN-10GU+AES10G-LN#DC X X X X - X X
5TCE-PCN-10GU+10G X X1 X X1 - X X1
5TCE-PCN-10GU+AES10G X X1 X X1 - X X1
5TCE-PCTN-8GU+10GS-LN#DC X X X X - X X
5TCE-PCTN-8GU+AES10GS-LN#DC X X X X - X X
10TCE-PCN-10G+100G(-GF) X X X X - X X
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
4TCA-PCN-4GUS+4G X - -
WCA-PCN-2G5U X2, 3 - -
WCE-PCN-100G - X -
WCE-PCN-100GB - X -
4WCE-PCN-16GFC X2 X2 -
5TCE-PCTN-10GU-LN#DC X X -
5TCE-PCTN-10GU+AES10G-LN#DC X X -
5TCE-PCTN-8GU+10GS-LN#DC X X -
5TCE-PCTN-8GU+AES10GS-LN#DC X X -
5TCE-PCN-10GU+10G X X1 -
5TCE-PCN-10GU+AES10G X X1 -
10TCE-PCN-10G+100G(-GF) X X -
10TCE-PCN-16GU+AES100G X X -
EDFA-C-D17-GC X X -
EDFA-C-D20-VGC-DM X X -
EDFA-C-D20-VLGC-DM X X -
EDFA-C-S20-GCB-DM X X -
EDFA-C-S26-VGC(B)-DM - - -
RAMAN-C10 - - -
2RAMAN-C15-LL - - -
AMP-S20L-C15 - - -
AMP-S20H-C15 - - -
ROADM-
8ROADM- 8ROADM- 9ROADM- 4ROADM-C96/0/OPM
C80/0/OPM
C40/0/OPM C80/0/OPM C96/0/OPM
100 GHz 50 GHz 100 GHz 50 GHz
XFP/16GFC/#xxxxxL/SM/LC#Dxx X - X - - X -
XFP/16GFC/#19xxxL50/SM/LC X X X X - X X
XFP/11G/DCTV/SM/LC X X X X - X X
XFP/11G/DCTLNR/SM/LC X X X X - X X
XFP/11G/DCTLN/SM/LC X X X X - X X
XFP/11G/Dxxxx.xxV/SM/LC#Dxx X - X - - X -
XFP/OTN11G/#19xxxV/SM/LC X - X - - X -
XFP/11G/#19xxxL50/SM/LC X X X X - X X
XFP/8G/#xxxxxL/SM/LC#Dxx X - X - - X -
SFP+/11GU/#19xxxL50/SM/LC X X X X - X X
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx X - X - - X -
SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx X - X - - X -
SFP/3GSDI/#xxxxxV/SM/LC X - X - - X -
CFP/4x28G/#19xxx-#19xxxL/SM/LC X X X X - X X
CFP/4x28G/#DCTL/SM/LC X X X X - X X
Module and System Specification
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Appendix A Overview of Modules
CCM-C40/8 CCM-C80/8
XFP/16GFC/#xxxxxL/SM/LC#Dxx X -
XFP/16GFC/#19xxxL50/SM/LC X X
XFP/11G/DCTV/SM/LC X X
XFP/11G/DCTLNR/SM/LC X X
XFP/11G/DCTLN/SM/LC X X
XFP/11G/Dxxxx.xxV/SM/LC#Dxx X -
XFP/OTN11G/#19xxxV/SM/LC X -
XFP/11G/#19xxxL50/SM/LC X X
XFP/8G/#xxxxxL/SM/LC#Dxx X -
SFP+/11GU/#19xxxL50/SM/LC X X
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx X -
SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx X -
SFP/3GSDI/#xxxxxV/SM/LC X -
CFP/4x28G/#19xxx-#19xxxL/SM/LC - X
CFP/4x28G/#DCTL/SM/LC - X
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
network side X X
5TCE-PCTN-10GU+AES10G client side 1 X X
network side3 X X
5TCE-PCN-10GU+10G client side1 X X
network side X X
5TCE-PCN-10GU+AES10G client side 1 X X
network side3 X X
5TCE-PCTN-8GU+10GS client side1 X X
network side X X
5TCE-PCTN-8GU+AES10GS client side 1 X X
network side3 X X
10TCE-PCN-10G+100G client side1 X X
network side X -
10TCE-PCN-10G+100G-GF client side 1 X X
network side X -
10TCE-PCN-16GU+AES100G client side1 X X
network side - -
1. on individual ports
2. only supported for 8 G FC and 10 GbE LAN PHY
3. loop on the network port is only allowed for bypass applications when encryption is disabled
Versatile
Switched Channel Card Client Channel Card
Channel Protection Path Protection
Protection/ Protection Protection
Restoration
WCC-PCTN-100GB P
- (Uni/Bi,
Rev/Non-Rev)
10TCC-PCTN-10G+100GB P
(Uni/Bi,
Rev/Non-Rev)
WCC-PCTN-10G P
R (Uni/Bi,
(Bi, Non-Rev)
Rev/Non-Rev)1
4TCC-PCTN-2G7+10G R P
(Bi, Non-Rev) (Bi, Rev/Non-Rev)
10TCC-PCTN-4GUS+10G R P
(Bi, Non-Rev) (Bi, Rev/Non-Rev)
10TCC-PCN-2G7US+10G P
R P
(Uni/Bi,
(Bi, Non-Rev) (Bi, Non-Rev)
Rev/Non-Rev)
10WXC-PCN-10G R
(Bi, Non-Rev)
2WCC-PCN-10G P P
R
Versatile
Switched Channel Card Client Channel Card
Channel Protection Path Protection
Protection/ Protection Protection
Restoration
4TCA-PCN-4GU+4G P P P P
(Bi, Non-Rev) (Bi, Non-Rev) (Bi, Non-Rev) (Bi, Non-Rev)
4TCA-PCN-4GUS+4G R P P P
(Bi, Non-Rev) (Bi, Non-Rev) (Bi, Non-Rev) (Bi, Non-Rev)
WCA-PCN-2G5U P P
(Bi, Non-Rev) (Bi, Non-Rev)
WCE-PCN-100G R P
(Bi, Non-Rev) (Bi, Rev/Non-Rev)
WCE-PCN-100GB R P
(Bi, Non-Rev) (Bi, Rev/Non-Rev)
4WCE-PCN-16GFC P
(Bi, Non-Rev)
5TCE-PCTN-10GU+10G P
P
(Uni/Bi,
(Bi, Non-Rev)
Rev/Non-Rev)
5TCE-PCTN-10GU+AES10G P
R
(Uni/Bi,
(Bi, Non-Rev)
Rev/Non-Rev)
5TCE-PCN-10GU+10G P P
(Bi, Non-Rev) (Bi, Non-Rev)
5TCE-PCN-10GU+AES10G P P
(Bi, Non-Rev) (Bi, Non-Rev)
Module and System Specification
5TCE-PCTN-8GU+10GS P
(Bi, Non-Rev)
5TCE-PCTN-8GU+AES10GS R
(Bi, Non-Rev)
10TCE-PCN-16GU+AES100G R
(Bi, Non-Rev)
10TCE-PCN-10G+100G-GF R
(Bi, Non-Rev)
1. for “Bidirectional” only “Non-Revertive”
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Appendix A Overview of Modules
Legend
The following legend refers to the table for “Channel Module Protection
Capabilities” which shows the supported protection schemes of the channel
modules.
R = Restoration Bi = Bidirectional
Rev = Revertive Uni = Unidirectional
P = Protection Non-Rev = Non-Revertive
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
10TCC-PCTN-4GUS+10G
4TCC-PCTN-2G7+10G
4TCC-PCTN-10G+40G
2TWCC-PCN-2G7U
WCC-PC1N-2G7U
WCA-PCN-2G5U
WCC-PCTN-10G
2WCC-PCN-10G
2WCA-PCN-10G
Regeneration Capabilities
4TCC-PCTN-10G+40G BB,
-- -- -- -- -- -- -- --
PN
WCC-PCTN-10G BB, BN, PS
-- -- -- -- -- BC, PN --
PS BC, PS
4TCC-PCTN-2G7+10G BB, BB,
-- -- -- BC, PS -- BC, PN --
PS PN
10TCC-PCTN-4GUS+10G BB, BB, BN, PS
-- -- -- -- BC, PS --
PS PN BC, PS
10TCC-PCN-2G7US+10G BB, BN, PS
-- -- -- -- -- -- --
PS BC, PS
2WCC-PCN-10G BB, BN, PS
-- -- -- -- -- BC, PS --
PS BC, PS
2TWCC-PCN-2G7U BB,PS
-- -- -- -- -- BC, PS -- BN, PS
Module and System Specification
BC,PS
WCC-PC1N-2G7U BB,PS
-- -- -- -- -- -- -- BN, PS
BC,PS
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
5TCE-PCTN-8GU+AES10GS
5TCE-PCTN-10GU+AES10G
5TCE-PCN-10GU+AES10G
5TCE-PCTN-8GU+10GS
5TCE-PCTN-10GU+10G
5TCE-PCN-10GU+10G
4TCA-PCN-4GUS+4G
4TCA-PCN-4GU+4G
4WCE-PCN-16GFC
WCA-PCN-2G5U
WCC-PCTN-10G
2WCC-PCN-10G
2WCA-PCN-10G
Regeneration Capabilities
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Please find in Table 1340, Table 1341, Table 1342 and Table 1343 the data
rates and services supported by each channel module.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
OTU1e, OTU2e
STM-4, OC-12
Subset G.709
Fast Ethernet
STM-1, OC-3
STM-256,
STM-16,
STM-64,
OC-192
OC-768
HD-SDI
SD-SDI
OTU2V
OTU4V
OC-48
F2488
F9953
OTU1
OTU2
OTU2
OTU4
Mode
WCC-PCTN-100GA T N C
WCC-PCTN-100GB T N C
WCC-PCTN-10G W C N N
T C/N C/N C/N
4TCC-PCTN-2G7+10G M C C N N
10TCC-PCTN-4GUS+10G M C C C N N
10TCC-PCN-2G7US+10G M C C C C N
10TCC-PCTN-10G+100GB M C C C N
10WXC-PCN-10G XC C/N C/N 1
Services
OTU1e, OTU2e
STM-4, OC-12
Subset G.709
Fast Ethernet
STM-1, OC-3
STM-256,
STM-16,
STM-64,
OC-192
OC-768
HD-SDI
SD-SDI
OTU2V
OTU4V
OC-48
F2488
F9953
OTU1
OTU2
OTU2
OTU4
Mode
5TCE-PCTN-10GU+AES10G M C N
F N
T C N
5TCE-PCN-10GU+10G M C N
F N
T C N
5TCE-PCN-10GU+AES10G M C N
F N
T C N
5TCE-PCTN-8GU+10GS M N
F N
5TCE-PCTN-8GU+AES10GS M N
F N
10TCE-PCN-10G+100G M C N
10TCE-PCN-10G+100G-GF M C N
10TCE-PCN-16GU+AES100G M N
Module and System Specification
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Services
Networking Proprietary
10GbE WAN PHY
Coupling Link 1G
Coupling Link 2G
10GbE LAN PHY
Gigabit Ethernet
10G FC/FICON
10G InfiniBand
1G FC/FICON
2G FC/FICON
4G FC/FICON
8G FC/FICON
ADVA Optical
5G InfiniBand
100GbE
ESCON
16G FC
40GbE
Mode
2WCC-PCN-10G T C/N C/N C/N
2TWCC-PCN-2G7U M C C C
WCC-PCTN-100GA T C
WCC-PCTN-100GB T C
WCC-PCTN-10G W C C
T C/N C/N C/N
10TCC-PCTN-4GUS+10G M C C C C
10TCC-PCN-2G7US+10G M C
10TCC-PCTN-10G+100GB M C C
10WXC-PCN-10G T C/N
WCC-PC1N-2G7U T C/N
WCC-PC-2G7U T C/N
2PCA-PCN-10G M C N
10PCA-PCN-1G3+10G M C N
Services
Networking Proprietary
10GbE WAN PHY
Coupling Link 1G
Coupling Link 2G
10GbE LAN PHY
Gigabit Ethernet
10G FC/FICON
10G InfiniBand
1G FC/FICON
2G FC/FICON
4G FC/FICON
8G FC/FICON
ADVA Optical
5G InfiniBand
100GbE
ESCON
16G FC
40GbE
Mode
5TCE-PCN-10GU+AES10G M C C C C C
F C C C C C
T C C C
5TCE-PCTN-10GU+10G M C C C C C
F C C C C C
T C C C C
5TCE-PCTN-10GU+AES10G M C C C C C
F C C C C C
T C C C C
5TCE-PCTN-8GU+10GS M C C C C
F C C C C C
5TCE-PCTN-8GU+AES10GS M C C C C
F C C C C C
WCE-PCN-100G T C
Module and System Specification
WCE-PCN-100GB T C
4WCE-PCN-16GFC T C/N C/N C/N
10TCE-PCN-10G+100G M C C C
10TCE-PCN-10G+100G-GF M C C C
10TCE-PCN-16GU+AES100G M C C C C C
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Legend
Module and System Specification
The following legend refers to Table 1340 and Table 1341 and lists the abbreviations and their meanings for the services
supported on the FSP 3000R7 channel modules.
C = Client Ports
T = Transponder Mode
M = Multiplexer Mode
N = Network Ports
W = Wrapping Mode
F = Framed Mode
1.0625 Gbit/s
1.250 Gbit/s
1.485 Gbit/s
2.125 Gbit/s
125 Mbit/s
155 Mbit/s
200 Mbit/s
270 Mbit/s
360 Mbit/s
622 Mbit/s
Mode
2TWCC-PCN-2G7U M C C C
10TCC-PCTN-4GUS+10G M C C C C C
10TCC-PCN-2G7US+10G M C C C
WCC-PC1N-2G7U T C/N C/N C/N
2PCA-PCN-10G M
Data Rates
1.0625 Gbit/s
1.250 Gbit/s
1.485 Gbit/s
2.125 Gbit/s
125 Mbit/s
155 Mbit/s
200 Mbit/s
270 Mbit/s
360 Mbit/s
622 Mbit/s
Mode
5TCE-PCN-10GU+AES10G M C C C
F C C C
T
5TCE-PCTN-10GU+10G M C C C
F C C C
T
5TCE-PCTN-10GU+AES10G M C C C
F C C C
T
5TCE-PCTN-8GU+10GS M C C C
F C C C
5TCE-PCTN-8GU+AES10GS M C C C
F C C C
10.51875
39.81312
43.01841
10.6642
10.7092
9.95328
10.3125
10.7595
10.9747
11.0032
11.0491
11.0957
11.3176
120.579
14.025
Mode
2.488
103.1
111.8
Module and System Specification
4.25
10.0
5.0
2.5
8.5
WCC-PCTN-100GA T C C N
WCC-PCTN-100GB T C C N
WCC-PCTN-10G W C C N N N N
C/
T C/N C/N C/N C/N C/N C/N
N
4TCC-PC-2G7+10G M C C N N
10TCC-PCTN-4GUS+10G M C N N
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
2.666057
10.51875
39.81312
43.01841
9.95328
10.3125
10.6642
10.7092
10.7595
10.9747
11.0032
11.0491
11.0957
11.3176
120.579
14.025
Mode
2.488
103.1
111.8
4.25
10.0
2.5
5.0
8.5
10TCC-PCN-2G7US+10G M C C N
10TCC-PCTN-10G+100GB M C C C C N
10WXC-PCN-10G C/N C/N C/N
2WCC-PCN-10G C/
T C/N C/N C/N C/N C/N
N
2TWCC-PCN-2G7U T C/N C/N
M N N
WCC-PC1N-2G7U W C N
T C/N C/N
2PCA-PCN-10G M C/N
10PCA-PCN-1G3+10G M N
2WCA-PCN-10G T C/N C/N C/N C/N C/N C/N
4TCA-PCN-4GU+4G M C/N
T C/N
4TCA-PCN-4GUS+4G M N
WCA-PCN-2G5U T C/N C/N C/N
WCE-PCN-100G T C N
WCE-PCN-100GB T C N
4WCE-PCN-16GFC T C/N C/N C/N
2.666057
10.51875
39.81312
43.01841
9.95328
10.3125
10.6642
10.7092
10.7595
10.9747
11.0032
11.0491
11.0957
11.3176
120.579
14.025
Mode
2.488
103.1
111.8
4.25
10.0
2.5
5.0
8.5
5TCE-PCTN-10GU+AES10G M C C C N
F C C N
T C C C C C N N N N
5TCE-PCTN-8GU+10GS M C
F C C N
5TCE-PCTN-8GU+AES10GS M C
F C C N
10TCE-PCN-10G+100G M C C C N
10TCE-PCN-10G+100G-GF M C C C N
10TCE-PCN-16GU+AES100G M C C C N
Legend
The following legend refers to Table 1342 and Table 1343 and lists the abbreviations and their meanings for the data
rates supported on the FSP 3000R7 channel modules.
C = Client Ports
N = Network Ports
T = Transponder Mode
W = Wrapping Mode
M = Multiplexer
Module and System Specification
F = Framed Mode
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Management Protocols
Proprietary
ECC for Proprietary
GCCOS GCCO GCC1 GCC2 LDCC SDCC
[kbit/s] [kbit/s] [kbit/s] [kbit/s] [kbit/s] [kbit/s]
wrapped framing1
10 GbE [kbit/s]
[kbit/s]
WCC40GT-D C
N 1312 1312 1312
4TCC40GT-D C
N 5271 5271 5271
WCC10GT-D C 82 1312 1312 1312 192 1359
WCC10GT-LN N 82 1312 1312 1312 192 1359
WCC100GB C 13702 13702 13702
N 13702 13702 13702
4TCC10GT-D C 82 326 326 326 192
4TCC10GT-LN N 82 1312 1312 1312
10TCC10GT-D C
10TCC10GT-LN N 82 1312 1312 1312 576 192
10TCCS10GT-D C
10TCCS10GT-LN N 82 1312 1312 1312 576 192
10TCC10G C 82 326 326 326 192
N 82 1312 1312 1312
Management Protocols
Proprietary
ECC for Proprietary
GCCOS GCCO GCC1 GCC2 LDCC SDCC
[kbit/s] [kbit/s] [kbit/s] [kbit/s] [kbit/s] [kbit/s]
wrapped framing1
10 GbE [kbit/s]
[kbit/s]
WCC2G7-1N C 82 326 326 326 192
N 82 326 326 326 192
4TCC2G5 C
N 192
2PCA10G 4 C
N
10PCA10G2 C
N
4TCA4G C
N 1000 5
4TCA4GUS C
N 1000
2TCA2G5 C
N 1000
2TCA2G5S C
N 1000
WCE100G C
N 13702
Module and System Specification
WCE100GB C
N 13702
5TCE10GT-D C
N 1312
5TCE10G C
N 1312
5TCE10GTAES-D C
N 1312
5TCE10GAES C
N 1312
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Management Protocols
Proprietary
ECC for Proprietary
GCCOS GCCO GCC1 GCC2 LDCC SDCC
[kbit/s] [kbit/s] [kbit/s] [kbit/s] [kbit/s] [kbit/s]
wrapped framing1
10 GbE [kbit/s]
[kbit/s]
5TCES10GT-D C
N 576 192
5TCES10GTAES-D C
N 576 192
10TCE100GAES C
N 13702
10TCE-PCN-10G+100G C
(10TCE100G) N 1312
10TCE-PCN-10G+100G-GF C
(10TCE100G) N 1312
1. This refers specifically to ADVA Optical Networking proprietary framing.
2. ECC on OTU2 (on each traffic port)
3. ECC on OTU2e (on each traffic port)
4. In-band management is provided via Ethernet ELine-PPP (IP over PPP over VLAN EVC) at 1Mbit/s per ECC.
5. Not supported in TRANSW mode.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
WCE-PCN-100GB X --
4WCE-PCN-16GFC X --
5TCE-PCTN-10GU+10G X X
5TCE-PCN-10GU+10G X X
5TCE-PCTN-10GU+AES10G X X
5TCE-PCN-10GU+AES10G X X
5TCE-PCTN-8GU+10GS X X
5TCE-PCTN-8GU+AES10GS X X
10TCE-PCN-10G+100G X --
10TCE-PCN-10G+100G-GF X --
10TCE-PCN-16GU+AES100G X --
1. Ethernet client only
2. Sending Idle characters
3. Not in TransW mode
4. Not for STM-16/OC-12
Pluggable Interfaces
Module and System Specification
Parameters
First Fiber / Cable Nominal Sensitivity
Data Rates [Gbit/s] Output Power [dBm]
Rel. Type Wavelength [nm] Port [dBm]1
XFP/10G/850I/MM/LC 7.01 MM 850 9.9532 / 10.3125 / -8.0 to -1.0 -11.0 to -1.0
10.51875
XFP/11G/1310S/SM/LC 7.02 SM 1310 9.9532 / 10.3125 / -6.0 to -1.0 -13.0 to -1.0
10.51875 / 10.6642 /
10.709 / 11.0491 /
11.0957 / 11.317
XFP/11G/1550L/SM/LC 7.1 SM 1550 9.9532 / 10.3125 / -1.0 to +2.0 -11.0 to -1.0
10.51875 / 10.6642 /
10.709 / 11.0491 /
11.0957 / 11.317
XFP/8G/1310S/SM/LC 9.2 SM 1310 4.25 / 8.5 -6.0 to -1.0 -10.0 to +0.5
XFP/8G/850I/MM/LC 9.2 MM 850 4.25 / 8.5 -8.0 to -1.0 -11.0 to -1.0
SFP+/16GFC/1310S/SM/LC 11.2 SM 1310 4.25 / 8.5 / 14.025 -5.0 to +2.0 -12.0 to +2.0
SFP+/16GFC/850I/MM/LC 11.2 MM 850 4.25 / 8.5 / 14.025 -8.0 to 0.0 -10.0 to -1.0
SFP+CDR/10GU/1550L/SM/LC 11.2 SM 1550 8.5 / 9.9533 / -5.0 to +4.0 -16.0 to -1.0
10.0 / 10.3125
SFP+CDR/11GU/1310S/SM/LC 11.2 SM 1310 8.5 / 9.9533 / -6.0 to -1.0 -11.0 to +0.5
Parameters
First Fiber / Cable Nominal Sensitivity
Data Rates [Gbit/s] Output Power [dBm]
Rel. Type Wavelength [nm] Port [dBm]1
SFP+CDR/11GU/CxxxxS/SM/LC 12.3 SM 1271, 1291, 9.9532 / 10.0 / -5.0 to 0.0 -13.0 to 0.0
1311, 1331 10.3125 / 10.5187 /
10.709 / 10.754 /
11.0491 / 11.0957 /
11.3176
SFP+CDR/10GU/850I/MM/LC 11.2 MM 850 8.5 / 10.3125 -8.0 to 0.0 -10.0 to -1.0
SFP+/10G/1310S/SM/LC 9.3 SM 1310 5.0 / 8.5 / 9.953 / -8.0 to -0.5 -14.0 to 0.0
10.0 / 10.3125 /
10.51875
SFP+/10G/850I/MM/LC 9.3 MM 850 5.0 / 8.5 / 10.0 / -8.0 to -1.0 -11.0 to -1.0
10.3125 / 10.51875
SFP+/11GU/CxxxxL/SM/LC 12.1 SM 1471, 1491, 8.5 / 9.9532 / 10.0 / -4 to +4 -16.0 to -1.0
1511, 1531, 10.3125 / 10.5187 /
1551, 1571, 10.709 / 10.754 /
1591, 1611 10.7595 / 10.9747 /
11.0491 / 11.0957 /
11.3176
SFP+/11GU/1310S/SM/LC 12.1 SM 1310 5.02 / 8.5 / 9.9533 / -8 to -1 -13.0 to -1.0
10.0 / 10.3125 /
10.5187 / 10.709 /
10.7595 / 10.9747 /
11.0491 / 11.0957 /
Module and System Specification
11.3176
SFP+/11GU/850I/MM/LC 12.1 MM 850 5.02 / 8.5 / 9.9533 / -8 to -1 -11.0 to -1.0
10.0 / 10.3125 /
10.5187 / 10.709 /
10.754 / 10.9747 /
11.0491 / 11.0957 /
11.3176
SFP+/8GU/1310S/SM/LC 9.3 SM 1310 2.125 / 4.250 / 8.5 -8.5 to 0.5 at 8.5 Gbit/s -14.0 to 0.0
-8.5 to -3.0 at 2.25 / 4.25
Gbit/s
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Parameters
First Fiber / Cable Nominal Sensitivity
Data Rates [Gbit/s] Output Power [dBm]
Rel. Type Wavelength [nm] Port [dBm]1
SFP+/8GU/850I/MM/LC 9.3 MM 850 2.125 / 4.250 / 8.5 -9.0 to -2.0 -10.0 to 1.0
SFP/4GU/1310S/SM/LC 7.01 SM 1310 1.0625 / 2.125 / 4.25 -9.0 to -1.0 -18.0 to -1.0
SFP/4GU/850I/MM/LC 7.01 MM 850 1.0625 / 2.125 / 4.25 -10.0 to -2.5 -14.0 to 0.0
SFP/2G5U/1310S/SM/LC 7.01 SM 1310 0.1 to 2.67 -10.0 to -3.0 -16.0 to -3.0
(HW Rev. 1.0.1) MM
SFP/2G5U/1310S/SM/LC 7.1 SM 1310 0.1 to 2.67 -5.0 to 0.0 -18.0 to 0.0
(HW Rev. 1.0.2) MM
SFP/2G5U/1310S/SM/LC 10.1 SM 1310 0.1 to 2.67 -5.0 to 0.0 -18.0 to 0.0
(HW Rev. 2.01) MM
SFP/2G5U/1310L/SM/LC 7.01 SM 1310 0.1 to 2.67 -2.0 to +3.0 -27.0 to -9.0
SFP/HS/1310S/SM/LC 7.01 SM 1310 1.0625 / 1.25 -10.0 to -3.0 -19.0 to -3.0
MM
SFP/CL/1310I/SM/LC 7.01 SM 1310 0.1 to 2.67 -10.0 to -3.0 -19.0 to -3.0
MM
SFP/2G1/850I/MM/LC 7.01 MM 850 1.0625 / 1.25 / 2.125 -10.0 to -3.0 -15.0 to -3.0
/ 2.5
SFP/GBE/1310S/SM/LC/TIN 10.2 SM 1310 1.25 -9.0 to -3.0 -20.0 to -3.0
SFP/GBE/1310L/SM/LC/TIN 10.2 SM 1310 1.25 -5.0 to 2.0 -23.0 to -3.0
SFP/GBE/1550V/SM/LC/TIN 10.2 SM 1550 1.25 0.0 to 5.0 -24.0 to -3.0
SFP/GBE/850I/MM/LC/TIN 10.2 SM 850 1.25 -9.5 to 0.0 -17.0 to 0.0
SFP/GBE/B1310S/SM/LC 12.1 SM 1310 1.25 -9.0 to -3.0 -20.0 to -3.0
Parameters
First Fiber / Cable Nominal Sensitivity
Data Rates [Gbit/s] Output Power [dBm]
Rel. Type Wavelength [nm] Port [dBm]1
SFP/3GSDI/ELECTRICAL/HBNC 11.2 Belden - 0.27 / 0.36 / 1.485 / - -
1694A, 75 Ω 2.97
CFP/112G/LR10R/SM/LC 11.1 SM 1523, 1531, 1539 103.125 / 111.81 -4.5 to 3.53 -9.5 to 3.54
1547, 1555, 1563
1571, 1579, 1587
1595
CFP/112G/LR4/SM/LC 11.1 SM 1295.56, 1300.05 103.125 / 111.81 -4.3 to 4.53 -10.6 to 4.54
1304.58, 1309.14
CFP/103G/SR10/MM/MPO 12.1 MM 840 to 860 MM103.125 -7.6 to+2.45 -9.5 to +2.44
1. Sensitivity and reach depend on the data rate, fiber type and client equipment interface signal quality.
2. 5.0 Gbit/s for HW rev. 2.01 or newer
3. Average launch power
4. Average receive power
5. Transmitter output power range, each lane (min) is informative and not the principal indicator of signal strength. A transmitter with output power
below this value cannot be compliant; however, a value above this does not ensure compliance.
Module and System Specification
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Parameters
Fiber Type
Sensitivity
First Rel.
Opt.
Wave- Output Network Port
Data Rates [Gbit/s] dispersion
length Power [dBm]
[dBm]1 load [ps/nm]
XFP/16GFC/#xxxxxL/SM/LC#Dxx 11.2 SM DWDM 4.25 / 8.5 / 14.025 0.0 to +4.0 -13.0 to 0.0 0 to +400
XFP/16GFC/#19xxxL50/SM/LC 12.2 SM DWDM 4.25 / 8.5 / 14.025 0.0 to +4.0 -12.0 to 0.0 -100 to +100
XFP/11G/DCTV/SM/LC 9.3 SM DWDM 9.9532 /10.3125 / 10.51875 / 300 to 1000
10.6642 / 10.709 / 11.0032 / -1.0 to +3.0 -22.0 to -7.0
11.0491 / 11.0957 / 11.3176
XFP/11G/DCTLNR/SM/LC 10.3 SM DWDM 9.9532 /10.3125 / 10.51875 / -300 to +300
10.6642 / 10.709 / 11.0032 / -1.0 to +3.0 -17.0 to 0.0
11.0491 / 11.0957 / 11.3176
XFP/11G/DCTLN/SM/LC 11.1 SM DWDM 9.9532 /10.3125 / 10.51875 /
10.6642 / 10.709 / 11.0032 / 0.0 to +3.0 -16.0 to 0.0 -300 to +300
11.0491 / 11.0957 / 11.3176
XFP/11G/Dxxxx.xxV/SM/LC#Dxx 8.2 SM DWDM 9.9532 / 10.3125 / 10.51875
(HW Rev. 2.00) 10.6642 / 10.709 / 11.0032 0.0 to +4.0 -23.0 to -9.0 100 to 800
11.0491 / 11.0957 / 11.3176
XFP/11G/Dxxxx.xxV/SM/LC#Dxx 9.3 SM DWDM 9.9532 / 10.3125 / 10.51875
(HW Rev. 4.01) 10.6642 / 10.709 / 11.0032 0.0 to +4.0 -23.0 to -7.0 100 to 800
11.0491 / 11.0957 / 11.3176
XFP/11G/Dxxxx.xxV/SM/LC#Dxx 9.3 SM DWDM 9.9532 / 10.3125 / 10.51875
(HW Rev. 5.01) 10.6642 / 10.709 / 11.0032 0.0 to +4.0 -23.0 to -7.0 100 to 800
Parameters
Fiber Type
Sensitivity
First Rel.
Opt.
Wave- Output Network Port
Data Rates [Gbit/s] dispersion
length Power [dBm]
[dBm]1 load [ps/nm]
SFP/3GSDI/#xxxxxV/SM/LC 11.2 SM DWDM 0.27 to 2.97 0.0 to +3.0 -30.0 to -9.0 0.0 to +700
SFP/FE/C1490U/SM/LC 8.1 SM CWDM 0.125 0.0 to +4.0 -40.0 to -9.0 0
SFP/FE/C1510U/SM/LC 7.1 SM CWDM 0.125 0.0 to +4.0 -40.0 to -9.0 0
SFP/FE/C1490V/SM/LC 8.2 SM CWDM 0.125 0.0 to +4.0 -30.0 to 0.0 0
SFP/FE/C1510V/SM/LC 8.2 SM CWDM 0.125 0.0 to +4.0 -30.0 to 0.0 0
SFP/FE/D1528.77E/SM/LC 8.2 SM DWDM 0.125 +4.0 to +7.0 -42.0 to -10.0 0
SFP/FE/Dxxxxx.xxV/SM/LC 11.2 SM DWDM 0.125 0.0 to +4.0 -38.0 to -15.0 0.0 to 800
CFP/4x28G/#19xxx-#19xxxL/SM/LC 11.2 SM DWDM 103.125 / 111.81 +0.0 to +3.0 -10.0 to +3.0 0
CFP/4x28G/#DCTL/SM/LC 11.2 SM DWDM 103.125 / 111.81 +0.0 to +3.0 -10.0 to +3.0 0
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
1. Sensitivity and reach depend on the data rate, fiber type and client equipment interface signal quality.
2. Depends on OSNR and dispersion.
3. Depends on BER
XFP/11G/Dxxxx.xxV/SM/LC#Dxx
XFP/16GFC/#19xxxL50/SM/LC
XFP/OTN11G/#19xxxV/SM/LC
XFP/8G/#xxxxxL/SM/LC#Dxx
XFP/11G/#19xxxL50/SM/LC
XFP/11G/DCTLNR/SM/LC
XFP/11G/CxxxxV/SM/LC
XFP/11G/DCTLN/SM/LC
XFP/11G/CxxxxL/SM/LC
XFP/11G/1310S/SM/LC
XFP/11G/1550L/SM/LC
XFP/11G/DCTV/SM/LC
XFP/8G/CxxxxL/SM/LC
XFP/8G/1310S/SM/LC
XFP/10G/850I/MM/LC
XFP/8G/850I/MM/LC
WCC-PCTN-10G-LN#DC
WCC-PCTN-10G-V#DC X X X X X X
2PCA-PCN-10G
XFPs
2WCA-PCN-10G
2WCC-PCN-10G
10WXC-PCN-10G
4WCE-PCN-16GFC
10PCA-PCN-1G3+10G
10TCC-PCN-2G7US+10G
XFP/16GFC/#xxxxxL/SM/LC#Dxx
XFP/16GFC/#19xxxL50/SM/LC
XFP/11G/#19xxxL50/SM/LC
XFP/11G/Dxxxx.xxV/SM/LC#Dxx
X X X X
X X X
X
X X
X X
XFP/OTN11G/#19xxxV/SM/LC
XFPs at the Network Ports
XFP/11G/DCTV/SM/LC
X
X
X X X
X X X
XFP/11G/DCTLNR/SM/LC
XFP/11G/DCTLN/SM/LC
X X X
X X X
XFP/8G/#xxxxxL/SM/LC#Dxx
X
X X X X
XFP/11G/CxxxxL/SM/LC
X
X
X
X
X
XFP/11G/CxxxxV/SM/LC
X
X
X
X
XFP/8G/CxxxxL/SM/LC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
XFP/10G/850I/MM/LC
XFP/11G/1310S/SM/LC
XFP/11G/1550L/SM/LC
X X X
X X X
X X
X X X
XFP/8G/1310S/SM/LC
XFP/8G/850I/MM/LC
X X X X X X X
X X X X X X X
783 Module and System Specification
WCA-PCN-2G5U
WCC-PC1N-2G7U
2TWCC-PCN-2G7U
4TCA-PCN-4GU+4G
Modules
4TCA-PCN-4GUS+4G
10PCA-PCN-1G3+10G
10TCC-PCN-2G7US+10G
4TCC-PCTN-2G7+10G-LN#DC
10TCC-PCTN-4GUS+10G-V#DL
10TCC-PCTN-4GUS+10G-V#DC
4TCC-PCTN-2G7+10G-V#DC/DL
10TCC-PCTN-4GUS+10G-LN#DC
SFP+CDR/11GU/1310S/SM/LC
SFP+CDR/10GU/1550L/SM/LC
SFPs at the Client Ports
SFP+CDR/10GU/850I/MM/LC
SFP+CDR/11GU/CxxxxL/SM/LC
SFP+CDR/11GU/CxxxxS/SM/LC
SFP+/16GFC/1310S/SM/LC
SFP+/16GFC/850I/MM/LC
Table SFPs at the Client Ports - Part 1:
SFP+/10G/1310S/SM/LC
SFP+/8GU/1310S/SM/LC
SFP+/10G/850I/MM/LC
SFP+/8GU/850I/MM/LC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx
SFP/4GU/CxxxxV/SM/LC
SFP/4GU/CxxxxL/SM/LC
SFP/4GU/1310S/SM/LC
SFP/4GU/850I/MM/LC
X X X X X
SFPs
SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx
X
X
X
SFP/2G5U/CxxxxV/SM/LC
X
X
X
X
X
X
SFP/2G5U/CxxxxL/SM/LC
X
X
X
X
X
X
SFP/2G5U/1310S/SM/LC
X X X X X X X X
X
X X X X X X X X
X X X X X X X X
X
X
X
X
X
X X X X
X X X X
SFP/2G5U/1310L/SM/LC
X
X
X
X
X
X
X
X
SFP/HS/1310S/SM/LC
X X
X X
X X
SFP/CL/1310I/SM/LC
SFP/2G1/850I/MM/LC
X
X
X
X
X X X
X X X
X X X
X
SFP/GBE/850I/MM/LC/TIN
SFP/GBE/1310S/SM/LC/TIN
SFP/GBE/1310L/SM/LC/TIN
SFP/GBE/1550V/SM/LC/TIN
X X X X X X X
SFP/GBE/ELECTRICAL/RJ45
X
X X X X X X X X
X
X
SFP/3GSDI/ELECTRICAL/DIN
SFP/3GSDI/ELECTRICAL/HBNC
SFP/FE/C1490U/SM/LC
SFP/FE/C1510U/SM/LC
X X X X X
SCU
SCU-II
4WCE-PCN-16GFC
Modules
5TCE-PCN-10GU+10G
10TCE-PCN-10G+100G
5TCE-PCTN-10GU+10G
5TCE-PCTN-8GU+10GS
10TCE-PCN-10G+100G-GF
5TCE-PCTN-10GU+AES10G
5TCE-PCTN-8GU+AES10GS
10TCE-PCN-16GU+AES100G
SFP+CDR/11GU/1310S/SM/LC
X
SFP+CDR/10GU/1550L/SM/LC
SFP+CDR/10GU/850I/MM/LC
X X X
X X X
SFP+CDR/11GU/CxxxxL/SM/LC
SFP+CDR/11GU/CxxxxS/SM/LC
SFP+/16GFC/1310S/SM/LC
SFP+/16GFC/850I/MM/LC
X X X X X
SFP+/8GU/1310S/SM/LC
X
X
SFP+/10G/850I/MM/LC
X
X
X
SFP+/8GU/850I/MM/LC
X
X X X X
X
X X X X
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx
SFP/4GU/CxxxxV/SM/LC
SFP/4GU/CxxxxL/SM/LC
SFP/4GU/1310S/SM/LC
X
X
X
X
X
X
SFP/4GU/850I/MM/LC
X
X
X
X
X
X
SFPs
SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx
SFP/2G5U/CxxxxV/SM/LC
SFP/2G5U/CxxxxL/SM/LC
SFP/2G5U/1310S/SM/LC
X
X
X
X
X
X
X2
X2
SFP/2G5U/1310L/SM/LC
X
X
X
X
X
X
SFP/HS/1310S/SM/LC
SFP/CL/1310I/SM/LC
SFP/2G1/850I/MM/LC
X X X
X
X X X
X
X
X
X X X
X X X
SFP/GBE/850I/MM/LC/TIN
SFP/GBE/1310S/SM/LC/TIN
SFP/GBE/1310L/SM/LC/TIN
SFP/GBE/1550V/SM/LC/TIN
SFP/GBE/ELECTRICAL/RJ45
SFP/3GSDI/ELECTRICAL/DIN
SFP/3GSDI/ELECTRICAL/HBNC
SFP/FE/C1490U/SM/LC
SFP/FE/C1510U/SM/LC
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Modules SFPs
SFP+CDR/11GU/CxxxxS/SM/LC
SFP+/11GU/1310S/SM/LC
SFP/GBE/B1310S/SM/LC
SFP/GBE/B1490S/SM/LC
SFP/GBE/B1310L/SM/LC
SFP/GBE/B1490L/SM/LC
SFP+/11GU/850I/MM/LC
10TCC-PCTN-10G+100GB X X
4TCA-PCN-4GUS+4G X X X X
4WCE-PCN-16GFC X X
5TCE-PCN-10GU+10G X X
5TCE-PCN-10GU+AES10G X X
5TCE-PCTN-10GU+10G X X X X X X
5TCE-PCTN-10GU+AES10G X X X X X X
5TCE-PCTN-8GU+10GS X X X X X X
5TCE-PCTN-8GU+AES10GS X X X X X X
OSCM-PN
WCA-PCN-2G5U
WCC-PC1N-2G7U
2TWCC-PCN-2G7U
4TCA-PCN-4GU+4G
4TCA-PCN-4GUS+4G
5TCE-PCN-10GU+10G
5TCE-PCN-10GU+AES10G
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx
X
X
SFP/4GU/CxxxxV/SM/LC
X
X
SFP/4GU/CxxxxL/SM/LC
X
X
SFP/4GU/1310S/SM/LC
X
X
SFPs at the Network Ports
X SFP/4GU/850I/MM/LC
X
SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx
X
X
X
X
SFP/2G5U/CxxxxV/SM/LC
X
X
X
SFP/2G5U/CxxxxL/SM/LC
X
X
X
SFP/2G5U/1310S/SM/LC
X
X
X
SFP/2G5U/1310L/SM/LC
X
X
X
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFP/HS/1310S/SM/LC
X
X
SFP/CL/1310I/SM/LC
X
X
SFPs
SFP/2G1/850I/MM/LC
X
X
SFP/HS/850I/MM/LC
X
SFP/GBE/ELECTRICAL/RJ45
X
SFP/3GSDI/#xxxxxV/SM/LC
X
SFP/FE/C1490U/SM/LC
X
SFP/FE/C1510U/SM/LC
X
X
SFP/FE/C1510E/SM/LC
X
X
SFP/FE/C1490V/SM/LC
X
X
SFP/FE/C1510V/SM/LC
X
SFP/FE/D1528.77E/SM/LC
X
SFP/FE/Dxxxxx.xxV/SM/LC
X
SFP+/11GU/CxxxxL/SM/LC
X
X
SFP+/11GU/#19xxxL50/SM/LC
X
X
Appendix A Overview of Modules
CFPs
CFP/103G/SR10/MM/MPO
CFP/112G/LR10R/SM/LC
CFP/112G/LR4/SM/LC
WCC-PCTN-100GA X X
WCC-PCTN-100GB X X X
WCE-PCN-100G X X X
WCE-PCN-100GB X X X
CFPs
CFP/4x28G/#19xxx-#19xxxL/SM/LC
CFP/4x28G/#DCTL/SM/LC
CFP/112G/LR10R/SM/LC
WCE-PCN-100G X X
WCE-PCN-100GB X X
10TCE-PCN-10G+100G-GF X X X
10TCE-PCN-10G+100G X X X
10TCE-PCN-16GU+AES100G X X X
Table 1344 and Table 1345 provide maximum per channel input power values
of the fixed gain-controlled EDFAs. These are listed according to channel count
and DCM type.
History of Changes
This appendix lists significant changes (additions, corrections, etc.) made in the
separate issues of this documentation. They reflect all subreleases of the
product releases 9.3, 10.1, 10.2, 10.3, 11.1, 11.2, 12.1, 12.2, and 12.3.
Significant changes made to a MSS document of the product releases 7.0, 7.1,
8.1, 8.1.1, 8.2, 8.3, 9.1, and 9.2 can be found in a former version of the FSP
3000R7 Module and System Specification.
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
SFP/4GU/#xxxxxV/SM/LC#Dxx, SFP/2G5U/#xxxxxU/SM/LC#Dxx:
channel numbering changed to frequency based naming
• 4TCC-PCTN-10G+40G-L#DC: number of back-to-back cascades
added
• channel modules and pluggable transceivers: Maximum DGD and
Maximum PMD deleted and OSNR PMD penalty revised
• EDFA-C-D17-GC and EDFA-L-D17-GC: Max. optical output power
revised
• 4TCC-PCTN-2G7+10G-LN#DC, WCC-PCTN-10G-LN#DC,
10TCC-PCTN-4GU+10G-LN#DC and
10TCC-PCTN-4GUS+10G-LN#DC: Min. extinction ratio revised
• DCG-M/xxx/TWRS: Optical Characteristics revised
Issue B May 2010 • Sections of “Power Consumption” and “Interoperability of Channel
Modules” added to Chapter 1: Introduction
• SFP+/8GU/1310S/SM/LC, SFP+/8GU/850I/MM/LC: Bit error ratio
corrected
• SFP+/8GU/850I/MM/LC: Receiver dynamic range revised
• ROADM-C40/40/OPM-3HU/2DC, ROADM-C80/0/OPM,
8ROADM-C40/0/OPM, 8ROADM-C40/0/OPM: Optical Character-
istics - General revised
• 1PM/MM, 2PM/MM: Optical return loss deleted and Directivity
revised
• 2WCA-PCN-10G, WCA-PC-10G-V: Latency per pair revised
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• 2WCA-PCN-10G: “Latency per pair” revised
• 8ROADM-C40/0/OPM: value of “N-D Input total power” revised
• 4TCA-PCN-4GUS+4G: “Operation Modes” revised
• WCC-PCTN-10G-LN#DC: “Bit Error Rate Versus OSNR” revised
• WCC-PCTN-10G, 4TCC-PCTN-2G7+10G,
10TCC-PCTN-4GU+10G, 10TCC-PCTN-4GUS+10G,
5TCE-PCTN-10GU+10G, XFP/11G/DCTV/SM/LC, and
SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx: “Optimum dispersion load
range”, “Dispersion load range with 1 dB OSNR penalty” and Dis-
persion load range with 2 dB OSNR penalty” added and “Min. dis-
persion load”, Max. dispersion load” and “Optimum dispersion
load” deleted.
• DCG-M/xxx/TWRS: values of “Chromatic Dispersion” added
10.1 Issue A September • 4TCA-PCN-4GU+4G and 4TCA-PCN-4GUS+4G: Client Channel
2010 Card Protection added to “Protection scheme” and
SFP/GBE/ELECTRICAL/RJ45 added to Table of “Supported Cli-
ent SFPs”
• 5TCE-PCTN-10GU+10G: Tables of “Fault Monitoring - General for
all Variants”, “Performance Monitoring Client Interface - Ingress
Direction for all Variants”, “Performance Monitoring Network Inter-
face - Egress Direction for all Variants” and “Protection Switching
for all Variants” updated
• 8ROADM-C80/0/OPM, 2PCA-PCN-10G, EDFA-C-D27-GCB-DM
and DCG50-M/xxx/SSMF added
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
“Supported Network XFPs”
• Latency specifications added to all XFPs
• Preface revised
• 2WCA-PCN-10G: XFP/8G/850I/MM/LC and
XFP/8G/1310S/SM/LC added to “Supported Client XFPs”
• CCM-C40/8: specification revised
Issue F April 2012 • 40CSM/P-2HU#19590-#19200-DM: “Weight” revised
• EDFA-C-D20-VGC, EDFA-C-D20-VGC-DM,
EDFA-C-D20-VLGC-DM, EDFA-C-D27-GCB-DM,
EDFA-C-S20-GCB, EDFA-C-S20-GCB-DM: OPR/OPT accuracy
added
• XFP/11G/DCTV/SM/LC, XFP/11G/Dxxxx.xxV/SM/LC#Dxx,
XFP/8G/#xxxxxL/SM/LC#Dxx, XFP/11G/CxxxxV/SM/LC,
XFP/11G/1550L/SM/LC: Min. extinction ratio revised
• 4TCA-PCN-4GUS+4G: “Operation Modes” revised
• NCU-II, NCU, UTM, OSCM-PN, OSCM-V#1630 and
2OSCM-V#1630: Max. link distance added to table “Ethernet Inter-
face”
• Table “Channel Module Error Signaling on Client Port” added to
Appendix A
• 10PCA-PCN-1G3-10G: “Supported Client SFPs” updated
• 10TCC-PCTN-4GUS+10G: “Restoration time” updated
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• Preface revised
• 2WCA-PCN-10G: XFP/8G/850I/MM/LC and
XFP/8G/1310S/SM/LC added to “Supported Client XFPs”
• CCM-C40/8: specification revised
Issue D April 2011 • OSCM-PN, OSCM-V#1630 and 2OSCM-V#1630: “Max. number of
OSC modules per node” revised
• SFP/4GU/CxxxxV/SM/LC (HW Rev. 3.01): specification added
10.3 Issue A May 2011 • SH1HU-R/PF, FAN/1HU, PSU/1HU-R-AC-200,
EDFA-C-S26-VGC-DM, 5TCE-PCTN-10GU+AES10G,
XFP/11G/DCTLNR/SM/LC, SH7HU-R, PSU/7HU-R-DC,
PSU/7HU-R-DC-HP, 40CSM/2HU-#19590-#19200 and
40CSM-FL/2HU-#19590-#19200, 2RAMAN-C15-LL: specifica-
tions added
• 10TCC-PCTN-4GUS+10G and 10TCC-PC-4GU+10G:
SFP-OJDE/GBE/1310S/SM/LC and
SFP-OJDE/GBE/CxxxxV/SM/LC added to the “Supported Client
SFPs”
• 5TCE-PCTN-10GU+10G: 5G IB added to tables ”Client Ports -
Specifications for all Variants”, Operation Modes for all Variants,
System Performance for all Variants” added
• 2PCA-PCN-10G, 10PCA-PCN-1G3-10G and
4TCA-PCN-4GU+4G: “Operation Modes” revised
• Optical Amplifiers: value for “Polarization mode dispersion”
removed
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• Chapter 1, Introduction revised
• XFP/11G/DCTV/SM/LC, XFP/11G/DCTLNR/SM/LC,
XFP/11G/Dxxxx.xxV/SM/LC#Dxx: “OSNR penalty” revised
• XFP/11G/DCTLNR/SM/LC: “OPR measurement range” revised
• EDFA-C-S26-VGC-DM: “Max. OSC pilot input signal” added
• XFP/10G/850I/MM/LC: added HW Rev. 2.01
• PSU/7HU-AC-800, DCF1HU-P/x/MCOR, 2PSM-95/5,
10TCC-PCN-2G7US+10G, 5TCE-PCTN-8GU+10GS, ,
XFP/11G/DCTLN/SM/LC, XFP/10G/850I/MM/LC (HW Rev. 2.01):
specifications added
• WCC-PCTN-10G, 4TCC-PCTN-2G7+10G,
10TCC-PCTN-4GU+10G and 10TCC-PCTN-4GUS+10G: OPT
support on network ports added
• Appendix A, section “Channel Module Protection Support”
renamed into “Channel Module Protection Capabilities” and
revised, “ROADM Supported Channel Modules” and “ROADM
Supported Pluggable Transceivers” added
• “Required RAM consumption on NCU” for all modules revised
• SFP+/10G/1310S/SM/LC, SFP+/10G/850I/MM/LC,
SFP+/8GU/1310S/SM/LC and SFP+/8GU/850I/MM/LC: “OPR
measurement range” revised
XFP/10G/1310S/SM/LC, XFP/10G/1550L/SM/LC,
XFP/10G-2R/1310S/SM/LC, XFP/10G-2R/850I/MM/LC,
WCA-PC-10G, 8TCA-PC-2G1U+10G, 4TCA-LS+1G3,
8TCE-ESCON+2G5, ROADM-C40/40/OPM-3HU/2DC,
EDFA-C-S10
11.2 Issue A September • SCU-II, NCU-II-P, AMP-S20H-C15, AMP-S20L-C15,
2012 9ROADM-C96/0/OPM, 96CSM/4HU-#19600-#19125 specifica-
tions added
• WCC-PCTN-100GA: added OTU4 support to client interface and
“Receiver dynamic range” of the network port revised, value for
“Module delay” updated
• VSM: “Wavelength range” revised
• “Wavelength stability (operating)” added to following modules:
WCC-TN-40G-L#DC, 4TCC-PCTN-10G+40G-L#DC,
WCC-PCTN-100GA, WCC-PCTN-10G, 4TCC-PCTN-2G7+10G,
10TCC-PCTN-4GU+10G, 10TCC-PCTN-4GUS+10G,
5TCE-PCTN-10GU+10G, 5TCE-PCTN-10GU+AES10G,
5TCE-PCTN-8GU+10GS, 5TCE-PCTN-8GU+AES10GS,
XFP/11G/DCTV/SM/LC, XFP/11G/DCTLNR/SM/LC,
XFP/11G/DCTLN/SM/LC, XFP/11G/Dxxxx.xxV/SM/LC#Dxx,
XFP/OTN11G/#19xxxV/SM/LC, XFP/8G/#xxxxxL/SM/LC#Dxx,
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx,
SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• 10TCC-PCN-2G7US+10G: “Slot positions” revised
• CFP/112G/LR10R/SM/LC: Transmitter output power range, each
lane changed
• App A: Table “ROADM compatible Channel Modules an Amplifi-
ers” completed
• assignment of NCU and SCU type modules to the A and B slots for
the SH1HU-R/PF shelf corrected
• defined the environmental conditions for all 5TCE modules more
precisely
Issue C May 2013 General (concerns some parts of the MSS)
• corrected the modules' slot positions for the 7HU shelf types
• updated RAM consumption values for modules acc. to Rel. 11.2.3
Chapter 3
• 10TCC-PCN-2G7US+10G:
o max. frame size value added
o module delay values corrected
• 10TCC-PCTN-4GU+10G: added footnote for 1310nm and CWDM
SFP-OJDE to table 212 "Supported Client SFPs"
• 10TCC-PCTN-4GUS+10G: added footnote for 1310nm and
CWDM SFP-OJDE to table 239 "Supported Client SFPs"
• WCC-PCTN-100GA: Receiver wavelength range in table 142
"Network port" corrected
o
data rate of 10.7092 Gbit/s for F9953 added to table 567
• 10TCE-PCN-10G+100G:
o
Module delay values in table “System Performance” changed
o
Naming SFP+CDR devices in Table "Supported SFP/SFP+
Client Transceiver Types" corrected
• 10TCE-PCN-10G+100G-GF:
o added max. frame size for 10GbE services to Table "System
Performance"
o Naming SFP+CDR devices in Table "Supported SFP/SFP+
Client Transceiver Types" corrected
• 4WCE-PCN-16GFC: Footnote added to table "Supported Client
SFP+ Types" - (SFP+/10G/850I/MM/LC and
SFP+/10G/1310S/SM/LC for 10GbE only)
• WCE-PCN-100G added
Chapter 6
• CFP/4x28G/#19xxx-#19xxxL/SM/LC: using in a 100 GHz grid filter
system added
• SFP/FE/Dxxxxx.xxV/SM/LC, SFP/3GSDI/#xxxxxV/SM/LC,
SFP/3GSDI/ELECTRICAL/DIN, SFP/3GSDI/ELECTRI-
CAL/HBNC: added
• SFP+CDR/10GU/850I/MM/LC: data rate of 10.5 Gbit/s removed
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
o
Release 12.1
Prod Document Issue
Description
Rel. Version Date
12.1 Issue A August General (concerns some parts of the MSS)
2013
• updated maximum RAM consumption values for modules
according to Rel. 12.1
Chapter 1
• revised section “Environmental Conditions”
• updated the lists of standards in section “Compliance Statements”
Chapter 2
• added PSU/9HU-AC
• added PSU/1HU-R-DC-200
• added power consumption value for SH1HU-R/PF
• added power consumption value for FAN/1HU
• corrected power consumption value for the rack-mounted OTDR
• added NEBS compliance for SH9HU (GR-63, Issue 4:April 2012
NEBS Requirements, Telcordia SR-3580:2012 level 3)
• PSU/9HU-DC:
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
o
changed max. input current, nominal power consumption and
max. power consumption values
o
added note regarding electrical specifications
Chapter 3
• WCC-PC1N-2G7U: added the prase "ITU-T G.8262 and IEEE
1588v2 compliant transparent Ethernet transport" to client port
-Protocols
• added WCC-PCTN-100GB
• added 10TCC-PCTN-10G+100GB
• added 10WXC-PCN-10G
• The following discontinued modules has been removed:
o
4TCC-PCN-2G1U+2G5
o
10TCC-PCTN-4GU+10G
Chapter 4
• WCA-PC-10G has been removed (discontinued module)
• 4TCA-PCN-4GUS+4G: added note on compatibility ITU-T G.813
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• SFP+CDR/10GU/850I/MM/LC: changed “transmitter and receiver
fiber type” as well as “max. link distance”
• SFP+/10G/850I/MM/LC:
changed the OPR measurement range to -18 dBm ... 2 dBm
• CFP/4x28G/#DCTL/SM/LC: Entry in “Operating frequency range”
changed
• The following discontinued SFPs has been removed:
o
SFP/4GU/CxxxxL/SM/LC (only 1271 to 1451 nm)
o
SFP/2G5U/CxxxxV/SM/LC (only 1271 to 1451 nm)
o
SFP-OJDE/GBE/CxxxxV/SM/LC
Chapter 7
• The following discontinued modules has been removed:
o
OSCM-V#1630
o
2OSCM-V#1630
Chapter 8
• added 4ROADM-C96/0/OPM
• 9ROADM-C96/0/OPM: corrected slot positions in table “General
Information”
• CCM-C80/8: changed MTBF value
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• PSU/7HU-AC-HP: defined circuit breaker more precisely in table
“Electrical Specifications”
• PSU/7HU-AC-800: defined circuit breaker more precisely and cor-
rected value for min. current rating in table “Electrical Specifica-
tions”
• PSU/1HU-R-AC: defined circuit breaker more precisely in table
“Electrical Specifications”
• PSU/1HU-R-AC-200: defined circuit breaker more precisely in
table “Electrical Specifications”
Chapter 3
• 10WXC-PCN-10G: added row for “Max power consumption in
stand-alone applications” and corrected value for “typ. power con-
sumption” in table “General Information”
• WCC-PCTN-100GB: removed “Loss of sequence synchronisa-
tion” from table “Link Test PRBS Functionality”
Chapter 4
• The following channel modules have been discontinued:
2TCA-PCN-1G3+2G5, 2TCA-PCN-622M+2G5
• SFP/2G5U/CxxxxV/SM/LC:
changed OPR measurement range to -33dBm to -6dBm
• The following discontinued XFP/SFPs removed:
XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev. 2.00),
SFP/2G5U/1310S/SM/LC (HW Rev. 1.01 and 1.02), and
SFP-OJDE/GBE/1310S/SM/LC
Chapter 7
• NCU (NCU2E) removed (discontinued module)
Chapter 8
• Added NCU types supported by the individul ROADMs
Chapter 9
• 1PM/MM: corrected “Insertion loss” table “Optical Characteristics”
• 2PM/MM, corrected “Insertion loss” table “Optical Characteristics”
Appendix A
• Updated tables in section “Assignment of Pluggable Transceivers”
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
• CFP/112G/LR10R/SM/LC: added OPT/OPT accuracy
• CFP/112G/LR4/SM/LC: added OPT/OPT accuracy
• Max. module delay values for the following pluggable transceivers
added:
SFP+CDR/10GU/1550L/SM/LC, SFP+CDR/10GU/850I/MM/LC,
SFP+CDR/11GU/1310S/SM/LC, SFP+/10G/1310S/SM/LC,
SFP+/10G/850I/MM/LC, SFP+/11GU/CxxxxL/SM/LC,
SFP+/11GU/CxxxxL/SM/LC, SFP+/11GU/1310S/SM/LC,
SFP+/11GU/850I/MM/LC, SFP+/8GU/1310S/SM/LC,
SFP+/8GU/850I/MM/LC
• XFP/16GFC/#xxxxxL/SM/LC#Dxx:
Max. module delay changed to 3 ns
Appendix A
• Table “ROADM Supported Channel Modules and Amplifier” cor-
rected
• Table “CCM Supported Channel Modules and Amplifiers” cor-
rected
Release 12.2
Prod Document Issue
Description
Rel. Version Date
12.2 Issue A December General (concerns some parts of the MSS)
2013
• Updated maximum RAM consumption values for modules
according to Rel. 12.2
Chapter 2
• added SH1HU-HP/E-TEMP/2DC shelf
Chapter 3
• WCC-PCTN-100GB:
Added Client channel card protection and versatile switched pro-
tection
• 10TCC-PCTN-10G+100GB:
Added Full STM64/OC192 support
• 10TCC-PCN-2G7US+10G:
o
Added support of STM-1/OC-3, STM-4/OC-12,
STM-16/OC-48 and OTU1 signals
o
Added support of client channel card protection
o
Added FR-ALS functionality with pulses in 5 sec.
o
Added support of ECC on client ports
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
o
Added XFP/11G/#19xxxL50/SM/LC
• 2TWCC-PCN-2G7U
o Added ODU0 mapping
o Rate Limiting
Chapter 5
• 5TCE-PCTN-10GU+AES10G:
Max. power consumption value corrected (copy and paste error)
Chapter 7
• OSCM-PN: added statement on the OLM functionality
Chapter 8
• Added OPT/OPR 50ms sampling rate specification to the
9ROADM-C96/0/OPM
Chapter 9
• Added Y-cable variants
• Added EFFA-S20L
• Added EDFA-S20H
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
o
EDFA-S20L
o
RAMAN-C10
Issue B January Chapter 3
2014
• 2TWCC-PCN-2G7U
added Client Channel Card protection feature
• 10WXC-PCN-10G
removed XFP/11G/Dxxxx.xxV/SM/LC#Dxx from table “ Supported
SFPs“ and added XFP/11G/Dxxxx.xxV/SM/LC#Dxx
Chapter 4
• 2WCA-PCN-10G
added XFP/8G/CxxxxL/SM/LC to table “Supported Network
XFPs”
Chapter 6
• CFP/112G/LR4/SM/LC
added OPR measurement range to table “Technical Data”
Chapter 8
• 9ROADM-C96/0/OPM
corrected channel spacing in table “Optical Characteristics -Gen-
eral”
Chapter 3
• WCC-PCTN-100GA:
corrected MTBF value in table 183
• WCC-PCTN-100GB:
o
added value for “Max. Ethernet Frame Size” to table 169
o
corrected MTBF value in table 162
o
added SyncE compliance (table 164 „Jitter and Wander
Compliance“)
• 10TCC-PCTN-10G+100GB:
o added SyncE compliance (table 202 „Jitter and Wander
Compliance“)
o added value for “Max. Ethernet Frame Size” to table 207
• 10TCC-PCN-2G7US+10G:
corrected MTBF value in table 302
• 10WXC-PCN-10G:
o replaced XFP/11G/#xxxxxV/SM/LC#Dxx with
XFP/11G/Dxxxx.xxV/SM/LC#Dxx in table 331
o added SyncE compliance (table 331 „Jitter and Wander
Compliance“)
Chapter 4
• 2WCA-PCN-10G:
added XFP/8G/CxxxxL/SM/LC to table 471
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Release 12.3
Prod Document Issue
Description
Rel. Version Date
12.3 Issue A March 2014 General (Concerns some chapters of the MSS)
• Maximum RAM consumption values on NCU for modules
according to Rel. 12.3 updated
Chapter 1
• section “Optical Power Measurement”
Chapter 2
• SH1HU-HP/E-TEMP/2DC
Safety instruction added
Chapter 3
• The following discontinued modules removed:
o
WCC-TN-40G-L#DC
o
4TCC-PCTN-10G+40G-L#DC
• 10WXC-PCN-10G:
o added STM-64, OC-192, 10G-WAN data rates
o added TCAs on LO ODUk PMs
o added OTN mapping for STM-64, OC-192, 10G-WAN
added GCC1/ GCC2 for ODU2/ ODU2e
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
Chapter 5
• WCE-PCN-100GB added
• WCE-PCN-100G: CCCP for 100GbE client services added
• 10TCE-PCN-16GU+AES100G added
• 5TCE-PCN-10GU+10G added
• 5TCE-PCN-10GU+AES10G added
• 4WCE-PCN-16GFC
o SFP+/11GU/850I/MM/LC added as client plug
o SFP+/11GU/1310S/SM/LC added as client plug
• 5TCE-PCTN-10GU+10G
o
SFP+/11GU/850I/MM/LC added as client plug
o
SFP+/11GU/1310S/SM/LC added as client plug
• 5TCE-PCTN-10GU+AES10G
o
SFP+/11GU/850I/MM/LC added as client plug
o
SFP+/11GU/1310S/SM/LC added as client plug
• 5TCE-PCTN-8GU+10GS
o SFP+/11GU/850I/MM/LC added as client plug
o SFP+/11GU/1310S/SM/LC added as client plug
FSP 3000R7 R 12.3 80000027945 Issue A, © 2014 ADVA Optical Networking SE - Confidential
o
Optical Characteristics - Client Ports
o
Fault Monitoring - General
o
Fault Monitoring EDFA Submodule
o
Performance Monitoring Client Interface - General
o
Performance Monitoring Network Interface - General
o
Performance Monitoring Virtual Channel at Network Port
o
Performance Monitoring EDFA Submodule
• CCM-C96/9 added
Chapter 9
• 8PSM added
• J/SM/4CS-#C1270-#C1330/LC/0400 added
Chapter 10
• 2EDFA-S20L-S10L added