HIGHLIGHTS

REVISION NO. 57 May 01/08

Pages which have been revised are outlined below, together with the Highlights of the
Revision

--------------------------------------------------------------------------------------
CH/SE/SU C REASON FOR CHANGE EFFECTIVITY
PAGES
--------------------------------------------------------------------------------------

CHAPTER 33
__________

L.E.P. 1-11 REVISED TO REFLECT THIS REVISION INDICATING


NEW,REVISED, AND/OR DELETED PAGES
T. OF C. REVISED TO REFLECT THIS REVISION
1
33-12-00 EFFECTIVITY UPDATED
12, 15-
21

33-14-00 CORRECTION/ADDITION/AMPLIFICATION ALL


502 REVISED TEXT

33-21-00 CORRECTION/ADDITION/AMPLIFICATION 101-199, 901-999,


19 ILLUSTRATION UPDATED.

33-27-00 MOD.28153K5806 INCORPORATED 101-199, 901-999,


506- 507, LIGHTS-CABIN-INTRODUCE READING LIGHT
511- 514 POWER SUPPLIES (KID)
EFFECTIVITY UPDATED (THROUGHOUT THE TEXT) 001-012, 014-099,

33-31-00 LAYOUT IMPROVED/MATERIAL RELOCATED ALL


501- 506

33-41-15 LAYOUT IMPROVED OR EFFECTIVITY UPDATED


411- 412

33-43-11 LAYOUT IMPROVED OR EFFECTIVITY UPDATED


406- 407

33-51-00 WARNING/NOTE/REASON FOR THE JOB AMENDED ALL


513- 514 EFFECTIVITY UPDATED (THROUGHOUT THE TEXT) 001-012, 014-099,

33-51-11 CORRECTION/ADDITION/AMPLIFICATION 901-901,


410- 411 NOTES ADDED.

33-HIGHLIGHTS Page 1 of 1
REVISION NO. 57 May 01/08

IAC
CHAPTER 33
__________

LIGHTS

LIST OF EFFECTIVE PAGES


_______________________
N, R or D indicates pages which are New, Revised or Deleted respectively
Remove and insert the affected pages and complete the Record of Revisions and
the Record of Temporary Revisions as necessary

CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE

RECORD 33-12-00 2 Aug01/96 33-12-12 01 408 Feb01/96


OF TEMP. 33-12-00 3 Aug01/96 33-12-12 01 409 Feb01/96
REVISION 33-12-00 4 Aug01/96 33-12-12 01 410 Feb01/96
33-12-00 5 Feb01/07 33-12-12 01 411 Feb01/96
L.E.P. R 1-11 May01/08 33-12-00 6 Feb01/07 33-12-12 02 401 Feb01/07
T. of C. R 1 May01/08 33-12-00 7 Feb01/07 33-12-12 02 402 Feb01/07
T. of C. 2 Feb01/07 33-12-00 8 May01/06 33-12-12 02 403 Feb01/07
T. of C. 3 Feb01/07 33-12-00 9 May01/06 33-12-12 02 404 Feb01/07
T. of C. 4 Aug01/07 33-12-00 10 May01/06 33-12-12 02 405 Feb01/07
T. of C. 5 Feb01/08 33-12-00 11 May01/06 33-12-13 401 Feb01/07
T. of C. 6 Feb01/08 33-12-00 R 12 May01/08 33-12-13 402 Feb01/07
T. of C. 7 Feb01/08 33-12-00 13 May01/06 33-12-13 403 Feb01/96
T. of C. 8 Feb01/08 33-12-00 14 Feb01/07 33-12-13 404 Feb01/07
T. of C. 9 Feb01/08 33-12-00 R 15 May01/08 33-12-13 405 Feb01/07
T. of C. 10 Feb01/08 33-12-00 R 16 May01/08 33-12-13 406 Feb01/07
T. of C. 11 Feb01/08 33-12-00 R 17 May01/08 33-12-13 407 Feb01/07
T. of C. 12 Feb01/08 33-12-00 R 18 May01/08 33-12-13 408 Feb01/07
T. of C. 13 Feb01/08 33-12-00 N 19 May01/08 33-12-13 409 Feb01/96
T. of C. 14 Feb01/08 33-12-00 N 20 May01/08 33-12-13 410 Aug01/06
T. of C. 15 Feb01/08 33-12-00 N 21 May01/08 33-12-13 411 May01/06
T. of C. 16 Feb01/08 33-12-00 501 Aug01/06 33-12-13 412 Feb01/96
T. of C. 17 Feb01/08 33-12-00 502 Aug01/06 33-12-13 413 Aug01/06
T. of C. 18 Feb01/08 33-12-00 503 Feb01/07 33-12-13 414 Aug01/06
T. of C. 19 Feb01/08 33-12-00 504 Feb01/07 33-12-14 401 Aug01/06
T. of C. 20 Feb01/08 33-12-00 505 Feb01/07 33-12-14 402 Aug01/06
T. of C. 21 Feb01/08 33-12-00 506 Feb01/07 33-12-14 403 Feb01/96
T. of C. 22 Feb01/08 33-12-00 507 Feb01/07 33-12-14 404 Feb01/96
T. of C. 23 Feb01/08 33-12-11 401 Feb01/96 33-12-14 405 Feb01/96
T. of C. 24 Feb01/08 33-12-11 402 Aug01/06 33-12-14 406 Aug01/06
T. of C. 25 Feb01/08 33-12-11 403 Feb01/96 33-12-14 407 Aug01/06
33-12-11 404 Feb01/96 33-12-14 408 Feb01/96
33-00-00 1 May01/07 33-12-11 405 Aug01/07 33-12-15 401 Aug01/06
33-00-00 2 May01/07 33-12-11 406 Nov01/06 33-12-15 402 Aug01/06
33-12-11 407 Nov01/07 33-12-15 403 Feb01/96
33-10-00 1 Feb01/07 33-12-11 408 Nov01/07 33-12-15 404 May01/06
33-10-00 2 Feb01/96 33-12-12 01 401 Feb01/96 33-12-15 405 Aug01/06
33-10-00 3 May01/06 33-12-12 01 402 May01/98 33-12-15 406 Aug01/06
33-10-00 4 May01/06 33-12-12 01 403 Feb01/96 33-12-17 401 Aug01/06
33-10-00 5 Feb01/07 33-12-12 01 404 Feb01/96 33-12-17 402 Aug01/06
33-10-00 6 Feb01/07 33-12-12 01 405 Feb01/96 33-12-17 403 Feb01/96
33-12-12 01 406 Feb01/96 33-12-17 404 Feb01/96
33-12-00 1 Feb01/07 33-12-12 01 407 Feb01/96 33-12-17 405 Aug01/06

33-L.E.P. Page 1
May 01/08

IAC
CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE

33-12-17 406 Aug01/06 33-14-00 8 May01/05 33-21-00 14 May01/07


33-12-17 407 Feb01/96 33-14-00 9 May01/05 33-21-00 15 May01/07
33-12-18 401 Feb01/07 33-14-00 10 May01/05 33-21-00 16 Feb01/08
33-12-18 402 Feb01/07 33-14-00 501 Aug01/07 33-21-00 17 Feb01/08
33-12-18 403 Feb01/07 33-14-00 R 502 May01/08 33-21-00 18 May01/07
33-12-18 404 Feb01/07 33-14-00 503 Nov01/06 33-21-00 R 19 May01/08
33-12-18 405 Feb01/07 33-14-00 504 Nov01/06 33-21-00 20 Feb01/08
33-12-18 406 Feb01/07 33-14-33 401 May01/06 33-21-00 21 Feb01/08
33-12-18 407 Feb01/07 33-14-33 402 Aug01/06 33-21-00 22 Aug01/07
33-12-18 408 Feb01/07 33-14-33 403 May01/06 33-21-00 23 Aug01/07
33-14-33 404 May01/05 33-21-00 24 Aug01/07
33-13-00 1 Feb01/96 33-14-33 405 May01/06 33-21-00 25 Aug01/07
33-13-00 2 Aug01/96 33-14-33 406 May01/06 33-21-00 26 Aug01/07
33-13-00 3 Aug01/96 33-14-33 407 Aug01/06 33-21-00 27 Aug01/07
33-13-00 4 Aug01/96 33-14-33 408 May01/06 33-21-00 28 Feb01/08
33-13-00 5 Aug01/96 33-14-51 401 May01/06 33-21-00 29 Feb01/08
33-13-00 501 Aug01/06 33-14-51 402 Aug01/06 33-21-00 30 Feb01/08
33-13-00 502 Feb01/07 33-14-51 403 Aug01/06 33-21-00 31 Feb01/08
33-13-00 503 Aug01/06 33-14-51 404 Aug01/06 33-21-00 32 Feb01/08
33-13-41 401 May01/07 33-14-51 405 Aug01/06 33-21-00 33 Feb01/08
33-13-41 402 Feb01/07 33-14-51 406 Aug01/06 33-21-00 34 Feb01/08
33-13-41 403 May01/07 33-14-51 407 Aug01/06 33-21-00 35 Feb01/08
33-13-41 404 Nov01/04 33-14-51 408 Aug01/06 33-21-00 36 Feb01/08
33-13-41 405 Nov01/04 33-14-51 409 Aug01/06 33-21-00 37 Feb01/08
33-13-41 406 Feb01/07 33-14-51 410 Aug01/06 33-21-00 501 Feb01/96
33-13-41 407 May01/07 33-14-51 411 Aug01/06 33-21-00 502 Feb01/07
33-13-41 408 Feb01/07 33-14-51 412 Aug01/06 33-21-00 503 May01/07
33-13-41 409 May01/07 33-14-51 413 Aug01/06 33-21-00 504 Feb01/08
33-13-41 410 May01/07 33-21-00 505 Nov01/07
33-13-42 401 Aug01/06 33-20-00 1 Nov01/07 33-21-00 506 Nov01/07
33-13-42 402 Aug01/06 33-20-00 2 May01/00 33-21-00 507 Feb01/08
33-13-42 403 Nov01/05 33-20-00 3 Nov01/04 33-21-00 508 Nov01/07
33-13-42 404 Nov01/05 33-20-00 4 Nov01/04 33-21-00 509 Nov01/07
33-13-42 405 Aug01/06 33-20-00 401 Nov01/05 33-21-00 510 Nov01/07
33-13-42 406 Aug01/06 33-20-00 402 May01/05 33-21-00 511 Nov01/07
33-13-42 407 Nov01/05 33-20-00 403 Nov01/05 33-21-00 512 Nov01/07
33-13-51 401 Feb01/96 33-20-00 404 May01/05 33-21-00 513 Nov01/07
33-13-51 402 Aug01/06 33-21-00 514 Feb01/08
33-13-51 403 Aug01/06 33-21-00 1 Feb01/08 33-21-00 515 Nov01/07
33-13-51 404 May01/06 33-21-00 2 Feb01/08 33-21-00 516 Feb01/08
33-13-51 405 May01/06 33-21-00 3 Aug01/07 33-21-00 517 Feb01/08
33-13-51 406 Aug01/06 33-21-00 4 Aug01/07 33-21-00 518 Feb01/08
33-13-51 407 Aug01/06 33-21-00 5 Nov01/06 33-21-00 519 Feb01/08
33-21-00 6 Feb01/08 33-21-00 520 Feb01/08
33-14-00 1 May01/06 33-21-00 7 Feb01/08 33-21-00 521 Feb01/08
33-14-00 2 May01/06 33-21-00 8 Feb01/08 33-21-00 522 Feb01/08
33-14-00 3 May01/05 33-21-00 9 Feb01/08 33-21-00 523 Feb01/08
33-14-00 4 May01/05 33-21-00 10 May01/07 33-21-00 524 Feb01/08
33-14-00 5 May01/06 33-21-00 11 Aug01/07 33-21-11 401 Feb01/08
33-14-00 6 May01/05 33-21-00 12 Aug01/07 33-21-11 402 Feb01/08
33-14-00 7 May01/05 33-21-00 13 May01/07 33-21-11 403 Feb01/08

33-L.E.P. Page 2
May 01/08

IAC
CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE

33-21-11 404 Feb01/08 33-24-11 410 May01/06 33-25-00 511 Feb01/08


33-21-11 405 Feb01/08 33-24-11 411 May01/06 33-25-00 512 Feb01/08
33-21-11 406 Feb01/08 33-24-11 412 May01/06 33-25-00 513 Feb01/08
33-21-11 407 Feb01/08 33-24-11 413 May01/06 33-25-00 514 Feb01/08
33-21-11 408 Feb01/08 33-24-11 414 May01/06 33-25-00 515 Feb01/08
33-21-11 409 Feb01/08 33-24-11 415 May01/06 33-25-00 516 Feb01/08
33-21-11 410 Feb01/08 33-24-11 416 May01/06
33-21-11 411 Feb01/08 33-24-11 417 May01/06 33-26-00 1 May01/07
33-21-11 412 Feb01/08 33-24-11 418 May01/06 33-26-00 2 May01/06
33-21-11 413 Feb01/08 33-24-11 419 Aug01/07 33-26-00 3 Feb01/08
33-21-11 414 Feb01/08 33-24-11 420 Aug01/07 33-26-00 4 Feb01/08
33-21-11 415 Feb01/08 33-24-11 421 May01/07 33-26-00 5 Aug01/07
33-21-11 416 Feb01/08 33-24-11 422 Aug01/07 33-26-00 6 Aug01/07
33-21-11 417 Feb01/08 33-24-11 423 May01/07 33-26-00 7 May01/07
33-21-12 401 May01/07 33-24-11 424 Aug01/07 33-26-00 8 May01/07
33-21-12 402 May01/07 33-24-11 425 Aug01/07 33-26-00 9 May01/07
33-21-12 403 Nov01/05 33-24-11 426 Aug01/07 33-26-00 10 May01/07
33-21-12 404 May01/06 33-24-11 427 Aug01/07 33-26-00 11 May01/07
33-21-12 405 May01/07 33-24-12 401 Feb01/07 33-26-00 12 Aug01/07
33-21-12 406 May01/07 33-24-12 402 Feb01/07 33-26-00 13 Aug01/07
33-21-12 407 May01/07 33-26-00 14 Feb01/08
33-25-00 1 Aug01/07 33-26-00 15 Aug01/07
33-23-00 1 Feb01/96 33-25-00 2 May01/06 33-26-00 16 Aug01/07
33-25-00 3 May01/06 33-26-00 501 Feb01/07
33-24-00 1 Feb01/07 33-25-00 4 Aug01/07 33-26-00 502 Feb01/07
33-24-00 2 Aug01/07 33-25-00 5 May01/07 33-26-00 503 May01/06
33-24-00 3 Aug01/07 33-25-00 6 Aug01/07 33-26-00 504 May01/06
33-24-00 4 May01/07 33-25-00 7 Aug01/07 33-26-00 505 May01/07
33-24-00 5 Aug01/07 33-25-00 8 Aug01/07 33-26-00 506 Aug01/07
33-24-00 6 Aug01/07 33-25-00 9 Aug01/07 33-26-00 507 Aug01/07
33-24-00 7 Aug01/07 33-25-00 10 Aug01/07 33-26-11 401 Feb01/07
33-24-00 8 Aug01/07 33-25-00 11 Aug01/07 33-26-11 402 Feb01/07
33-24-00 9 May01/07 33-25-00 12 Aug01/07 33-26-11 403 Aug01/06
33-24-00 10 Aug01/07 33-25-00 13 Aug01/07 33-26-11 404 Feb01/07
33-24-00 11 Aug01/07 33-25-00 14 Aug01/07 33-26-11 405 Feb01/07
33-24-00 12 Aug01/07 33-25-00 15 Aug01/07 33-26-11 406 Feb01/07
33-24-00 501 Feb01/96 33-25-00 16 Aug01/07 33-26-11 407 Aug01/06
33-24-00 502 Feb01/07 33-25-00 17 Aug01/07 33-26-11 408 Feb01/07
33-24-00 503 Feb01/07 33-25-00 18 Aug01/07 33-26-11 409 Feb01/07
33-24-00 504 Feb01/07 33-25-00 19 Aug01/07 33-26-11 410 Feb01/07
33-24-00 505 Feb01/07 33-25-00 20 Aug01/07 33-26-11 411 Feb01/07
33-24-00 506 Feb01/07 33-25-00 501 Feb01/08 33-26-11 412 Feb01/07
33-24-11 401 May01/06 33-25-00 502 Feb01/07 33-26-11 413 Feb01/07
33-24-11 402 May01/06 33-25-00 503 May01/06 33-26-11 414 Feb01/07
33-24-11 403 May01/06 33-25-00 504 May01/06 33-26-11 415 Feb01/07
33-24-11 404 May01/06 33-25-00 505 Feb01/07 33-26-23 401 Aug01/07
33-24-11 405 May01/06 33-25-00 506 Feb01/08 33-26-23 402 Feb01/07
33-24-11 406 May01/06 33-25-00 507 Feb01/08 33-26-23 403 Aug01/07
33-24-11 407 May01/06 33-25-00 508 Feb01/08 33-26-23 404 Aug01/07
33-24-11 408 May01/06 33-25-00 509 Feb01/08 33-26-23 405 Feb01/08
33-24-11 409 May01/06 33-25-00 510 Feb01/08 33-26-23 406 Aug01/07

33-L.E.P. Page 3
May 01/08

IAC
CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE

33-26-23 407 May01/07 33-27-38 403 Aug01/07 33-31-11 408 Feb01/07


33-26-23 408 Aug01/07 33-27-38 404 Aug01/07 33-31-11 409 Feb01/07
33-26-23 409 Aug01/07 33-27-38 405 Aug01/07 33-31-11 410 May01/06
33-26-23 410 Aug01/07 33-27-38 406 Aug01/07 33-31-11 411 Feb01/07
33-26-23 411 May01/07 33-27-41 401 Feb01/08 33-31-11 412 May01/06
33-26-23 412 May01/07 33-27-41 402 Feb01/08 33-31-11 413 Feb01/07
33-27-41 403 Feb01/07 33-31-11 414 Feb01/07
33-27-00 1 May01/07 33-27-41 404 Feb01/07 33-31-11 415 Feb01/07
33-27-00 2 May01/06 33-27-41 405 Feb01/07 33-31-11 416 May01/06
33-27-00 3 May01/07 33-27-41 406 Feb01/07 33-31-11 417 Feb01/07
33-27-00 4 Aug01/07 33-27-41 407 Feb01/07 33-31-11 418 Feb01/07
33-27-00 5 Aug01/07 33-27-41 408 Feb01/08 33-31-11 419 Feb01/08
33-27-00 6 Aug01/07 33-27-41 409 Feb01/07 33-31-11 420 Feb01/07
33-27-00 7 May01/07 33-27-41 410 Feb01/07 33-31-11 421 Feb01/07
33-27-00 8 Aug01/07 33-27-41 411 Feb01/07 33-31-11 422 Feb01/07
33-27-00 9 Aug01/07 33-27-41 412 Feb01/08 33-31-11 423 May01/06
33-27-00 10 Aug01/07 33-31-11 424 Feb01/07
33-27-00 11 Aug01/07 33-30-00 1 Feb01/07 33-31-11 425 Feb01/07
33-27-00 12 Aug01/07 33-30-00 2 May01/06 33-31-11 426 Feb01/07
33-27-00 13 Aug01/07 33-30-00 3 Feb01/07 33-31-11 427 Feb01/08
33-27-00 501 May01/06 33-30-00 4 May01/07 33-31-11 428 Feb01/07
33-27-00 502 Feb01/07 33-30-00 5 May01/06 33-31-11 429 Feb01/07
33-27-00 503 Aug01/07 33-30-00 6 Feb01/07 33-31-11 430 Feb01/07
33-27-00 504 Aug01/07 33-30-00 7 Feb01/07 33-31-11 431 Feb01/07
33-27-00 505 May01/07 33-30-00 8 Feb01/07 33-31-11 432 Feb01/07
33-27-00 R 506 May01/08 33-30-00 9 Feb01/07 33-31-11 433 Feb01/08
33-27-00 R 507 May01/08 33-30-00 10 May01/07 33-31-11 434 Feb01/07
33-27-00 508 May01/07 33-30-00 11 May01/07 33-31-11 435 Feb01/07
33-27-00 509 May01/07 33-30-00 12 May01/07
33-27-00 510 May01/07 33-30-00 13 May01/07 33-32-00 1 Feb01/96
33-27-00 R 511 May01/08 33-32-00 2 Aug01/96
33-27-00 R 512 May01/08 33-31-00 1 Feb01/07 33-32-00 3 Feb01/96
33-27-00 R 513 May01/08 33-31-00 2 May01/06 33-32-00 501 May01/06
33-27-00 N 514 May01/08 33-31-00 3 Feb01/07 33-32-00 502 Feb01/07
33-27-12 401 Aug01/07 33-31-00 4 May01/06 33-32-00 503 May01/06
33-27-12 402 Aug01/07 33-31-00 5 Feb01/07
33-27-12 403 May01/07 33-31-00 6 May01/06 33-34-00 1 May01/06
33-27-12 404 Aug01/07 33-31-00 R 501 May01/08 33-34-00 2 May01/06
33-27-12 405 Aug01/07 33-31-00 R 502 May01/08 33-34-00 3 Feb01/07
33-27-12 406 Aug01/07 33-31-00 R 503 May01/08 33-34-00 4 Feb01/07
33-27-12 407 Aug01/07 33-31-00 R 504 May01/08 33-34-00 5 Feb01/07
33-27-12 408 Feb01/08 33-31-00 R 505 May01/08 33-34-00 6 Feb01/07
33-27-12 409 Aug01/07 33-31-00 R 506 May01/08 33-34-00 7 Feb01/07
33-27-12 410 Aug01/07 33-31-00 507 Feb01/96 33-34-00 8 Feb01/07
33-27-12 411 Aug01/07 33-31-11 401 Feb01/07 33-34-00 9 Feb01/07
33-27-12 412 Feb01/08 33-31-11 402 Feb01/07 33-34-00 10 Feb01/07
33-27-12 413 Feb01/08 33-31-11 403 Feb01/07 33-34-00 11 Feb01/07
33-27-12 414 Feb01/08 33-31-11 404 May01/06 33-34-00 12 Feb01/07
33-27-12 415 Feb01/08 33-31-11 405 Feb01/07 33-34-00 501 Feb01/07
33-27-38 401 Aug01/07 33-31-11 406 Feb01/07 33-34-00 502 Feb01/07
33-27-38 402 Aug01/07 33-31-11 407 Feb01/08 33-34-00 503 Feb01/07

33-L.E.P. Page 4
May 01/08

IAC
CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE

33-34-00 504 Feb01/07 33-35-00 503 May01/06 33-37-11 421 May01/07


33-34-00 505 Feb01/07 33-35-00 504 May01/06 33-37-11 422 May01/07
33-34-00 506 Feb01/07 33-35-11 401 Feb01/96 33-37-11 423 May01/07
33-34-00 507 Feb01/07 33-35-11 402 Feb01/07 33-37-11 424 May01/07
33-34-00 508 Feb01/07 33-35-11 403 Feb01/07 33-37-11 425 May01/07
33-34-00 509 Feb01/07 33-35-11 404 Feb01/96 33-37-11 426 May01/07
33-34-11 301 May01/06 33-35-11 405 Feb01/07 33-37-11 427 May01/07
33-34-11 302 Feb01/07 33-35-11 406 Feb01/07 33-37-11 428 May01/07
33-34-11 303 Feb01/07 33-35-11 407 May01/02 33-37-11 429 Feb01/08
33-34-11 304 May01/06 33-35-11 408 Feb01/07 33-37-11 430 Feb01/08
33-34-11 305 Feb01/07 33-35-11 409 Feb01/07 33-37-11 431 May01/07
33-34-11 306 Feb01/07 33-35-11 410 Feb01/07 33-37-11 432 May01/07
33-34-11 307 Feb01/07 33-35-11 411 May01/02 33-37-11 433 May01/07
33-34-11 308 Feb01/07 33-37-11 434 May01/07
33-34-11 401 May01/06 33-37-00 1 May01/07
33-34-11 402 Feb01/07 33-37-00 2 May01/06 33-40-00 1 Feb01/96
33-34-11 403 Feb01/07 33-37-00 3 May01/07 33-40-00 2 Feb01/96
33-34-11 404 Feb01/07 33-37-00 4 May01/07 33-40-00 3 Feb01/96
33-34-11 405 Feb01/07 33-37-00 5 May01/07 33-40-00 4 Feb01/96
33-34-11 406 Feb01/07 33-37-00 6 May01/07 33-40-00 5 Feb01/96
33-34-11 407 Feb01/07 33-37-00 7 Feb01/07 33-40-00 6 Feb01/96
33-34-11 408 Feb01/07 33-37-00 8 May01/07 33-40-00 7 Feb01/96
33-34-11 409 Feb01/07 33-37-00 501 Feb01/96 33-40-00 8 Feb01/96
33-34-11 410 Feb01/07 33-37-00 502 Aug01/06 33-40-00 9 Feb01/96
33-34-11 411 Feb01/07 33-37-00 503 May01/07
33-34-11 412 Feb01/07 33-37-00 504 May01/07 33-41-00 1 Nov01/04
33-34-11 413 Feb01/07 33-37-00 505 May01/06 33-41-00 2 Feb01/96
33-34-12 401 Feb01/07 33-37-00 506 May01/06 33-41-00 3 Feb01/96
33-34-12 402 Feb01/07 33-37-00 507 Aug01/06 33-41-00 4 Nov01/04
33-34-12 403 May01/07 33-37-00 508 May01/06 33-41-00 401 May01/02
33-34-12 404 May01/06 33-37-00 509 May01/06 33-41-00 402 Nov01/00
33-34-12 405 May01/07 33-37-11 401 May01/07 33-41-00 403 Aug01/06
33-34-12 406 Feb01/07 33-37-11 402 May01/07 33-41-00 404 Nov01/05
33-34-12 407 May01/07 33-37-11 403 May01/07 33-41-00 405 Nov01/05
33-34-12 408 May01/06 33-37-11 404 May01/07 33-41-00 406 Nov01/05
33-34-12 409 Feb01/07 33-37-11 405 May01/07 33-41-00 407 Nov01/05
33-34-12 410 Aug01/06 33-37-11 406 May01/07 33-41-00 408 Nov01/05
33-34-12 411 May01/07 33-37-11 407 May01/07 33-41-00 409 Nov01/05
33-34-12 412 May01/07 33-37-11 408 May01/07 33-41-00 410 May01/06
33-34-12 413 Feb01/07 33-37-11 409 May01/07 33-41-00 411 Aug01/06
33-34-12 414 Aug01/06 33-37-11 410 May01/07 33-41-00 412 May01/06
33-34-12 415 Aug01/06 33-37-11 411 May01/07 33-41-00 413 May01/01
33-37-11 412 May01/07 33-41-00 414 May01/01
33-35-00 1 Feb01/07 33-37-11 413 May01/07 33-41-00 415 Aug01/06
33-35-00 2 Feb01/96 33-37-11 414 May01/07 33-41-00 416 Aug01/06
33-35-00 3 Feb01/07 33-37-11 415 May01/07 33-41-00 417 May01/06
33-35-00 4 Feb01/96 33-37-11 416 May01/07 33-41-00 418 Aug01/06
33-35-00 5 Feb01/96 33-37-11 417 Feb01/08 33-41-00 419 May01/01
33-35-00 6 Feb01/96 33-37-11 418 Feb01/08 33-41-00 501 May01/05
33-35-00 501 May01/02 33-37-11 419 May01/07 33-41-00 502 May01/05
33-35-00 502 Aug01/06 33-37-11 420 May01/07 33-41-00 503 Feb01/96

33-L.E.P. Page 5
May 01/08

IAC
CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE

33-41-00 504 Feb01/96 33-42-00 407 Feb01/08 33-43-11 408 Feb01/08


33-41-11 401 Nov01/98 33-42-00 408 Feb01/08 33-43-11 409 Aug01/06
33-41-11 402 Aug01/06 33-42-00 501 Feb01/07 33-43-11 410 Aug01/06
33-41-11 403 Feb01/96 33-42-00 502 Feb01/07 33-43-11 411 Aug01/06
33-41-11 404 Feb01/96 33-42-00 503 Feb01/07 33-43-11 412 Aug01/06
33-41-11 405 May01/06 33-42-00 504 Nov01/02 33-43-11 413 Feb01/07
33-41-11 406 May01/06 33-42-00 505 Nov01/03 33-43-11 414 May01/07
33-41-11 407 May01/06 33-42-00 506 Nov01/02 33-43-11 415 May01/07
33-41-11 408 Feb01/07 33-42-00 507 Nov01/02 33-43-11 416 Aug01/06
33-41-11 409 May01/06 33-42-00 508 Nov01/02 33-43-11 417 May01/07
33-41-11 410 Aug01/07 33-42-00 509 Nov01/02 33-43-11 418 May01/07
33-41-11 411 Aug01/07 33-42-00 510 Nov01/02 33-43-11 419 May01/07
33-41-11 412 Aug01/06 33-42-11 401 May01/04 33-43-11 420 Aug01/06
33-41-11 413 Aug01/06 33-42-11 402 May01/06 33-43-11 421 Aug01/06
33-41-11 414 Aug01/07 33-42-11 403 Aug01/06 33-43-11 422 Aug01/06
33-41-11 415 Aug01/07 33-42-11 404 Nov01/02 33-43-11 423 Aug01/06
33-41-11 416 Aug01/07 33-42-11 405 May01/06 33-43-11 501 May01/06
33-41-11 417 Aug01/07 33-42-11 406 May01/06 33-43-11 502 May01/06
33-41-11 418 Aug01/06 33-42-11 407 May01/06 33-43-11 503 May01/06
33-41-15 401 Aug01/06 33-42-11 408 Aug01/06 33-43-11 504 May01/06
33-41-15 402 Aug01/06 33-42-11 409 Aug01/06 33-43-11 505 May01/06
33-41-15 403 Nov01/04 33-42-11 410 Feb01/07 33-43-11 506 May01/06
33-41-15 404 May01/05 33-42-11 411 Aug01/06 33-43-11 507 May01/06
33-41-15 405 Aug01/06 33-42-11 412 May01/06 33-43-11 508 May01/06
33-41-15 406 Aug01/06 33-42-11 413 May01/06 33-43-11 509 May01/06
33-41-15 407 Aug01/06 33-42-11 414 Aug01/06
33-41-15 408 Aug01/06 33-42-11 415 May01/06 33-46-00 1 May01/06
33-41-15 409 Aug01/06 33-42-11 416 May01/06 33-46-00 2 May01/06
33-41-15 410 Nov01/04 33-42-11 417 May01/06 33-46-00 3 Feb01/96
33-41-15 R 411 May01/08 33-42-11 418 May01/07 33-46-00 4 May01/06
33-41-15 R 412 May01/08 33-42-11 419 May01/07 33-46-00 401 Nov01/07
33-41-15 413 May01/05 33-42-11 420 May01/07 33-46-00 402 Nov01/07
33-41-16 401 Aug01/07 33-42-11 421 May01/06 33-46-00 403 Nov01/07
33-41-16 402 Aug01/07 33-46-00 404 May01/04
33-41-16 403 Aug01/07 33-43-00 1 May01/06 33-46-00 405 Nov01/07
33-41-16 404 Feb01/08 33-43-00 2 May01/06 33-46-00 406 Nov01/07
33-41-16 405 Aug01/07 33-43-00 3 Feb01/96 33-46-00 407 Aug01/07
33-41-16 406 Aug01/07 33-43-00 401 Feb01/08 33-46-00 408 Nov01/07
33-41-16 407 Aug01/07 33-43-00 402 Feb01/08 33-46-00 409 Aug01/06
33-43-00 403 Feb01/08 33-46-00 410 Aug01/06
33-42-00 1 May01/05 33-43-00 404 Aug01/07 33-46-00 501 Aug01/06
33-42-00 2 Nov01/04 33-43-00 405 Aug01/07 33-46-00 502 Aug01/06
33-42-00 3 May01/05 33-43-00 501 Aug01/06 33-46-00 503 May01/06
33-42-00 4 May01/05 33-43-00 502 Aug01/06 33-46-00 504 May01/06
33-42-00 5 May01/05 33-43-11 401 May01/06 33-46-00 505 May01/06
33-42-00 401 Feb01/07 33-43-11 402 Aug01/06 33-46-11 401 Feb01/07
33-42-00 402 Feb01/08 33-43-11 403 Feb01/96 33-46-11 402 Feb01/07
33-42-00 403 Feb01/08 33-43-11 404 Feb01/08 33-46-11 403 May01/06
33-42-00 404 Nov01/04 33-43-11 405 Feb01/08 33-46-11 404 Feb01/07
33-42-00 405 Feb01/08 33-43-11 R 406 May01/08 33-46-11 405 Feb01/08
33-42-00 406 Feb01/08 33-43-11 R 407 May01/08 33-46-11 406 Feb01/07

33-L.E.P. Page 6
May 01/08

IAC
CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE

33-46-11 407 Feb01/07 33-46-12 422 May01/07 33-48-00 2 May01/06


33-46-11 408 Feb01/07 33-46-12 423 May01/07 33-48-00 3 May01/06
33-46-11 409 Feb01/07 33-46-12 424 May01/07 33-48-00 4 Feb01/07
33-46-11 410 Feb01/07 33-46-12 425 May01/07 33-48-00 5 Feb01/07
33-46-11 411 Feb01/07 33-46-12 426 May01/07 33-48-00 6 Feb01/07
33-46-11 412 Feb01/07 33-46-12 501 May01/06 33-48-00 7 May01/06
33-46-11 413 Aug01/06 33-46-12 502 May01/06 33-48-00 8 Feb01/07
33-46-11 414 Aug01/06 33-46-12 503 May01/06 33-48-00 9 May01/06
33-46-11 415 Aug01/06 33-46-12 504 May01/06 33-48-00 10 Nov01/07
33-46-11 416 Aug01/06 33-46-12 505 May01/06 33-48-00 11 Feb01/07
33-46-11 417 Feb01/07 33-46-12 506 May01/06 33-48-00 12 Nov01/07
33-46-11 418 May01/07 33-46-12 507 May01/06 33-48-00 13 May01/06
33-46-11 419 May01/07 33-46-12 508 May01/06 33-48-00 14 May01/06
33-46-11 420 Aug01/06 33-46-12 509 May01/06 33-48-00 15 May01/06
33-46-11 421 May01/07 33-48-00 401 Feb01/07
33-46-11 422 May01/07 33-47-00 1 Nov01/04 33-48-00 402 Feb01/07
33-46-11 423 May01/07 33-47-00 2 May01/98 33-48-00 403 Feb01/07
33-46-11 424 May01/07 33-47-00 3 May01/98 33-48-00 404 May01/06
33-46-11 425 May01/07 33-47-00 4 Nov01/04 33-48-00 405 Feb01/07
33-46-11 426 May01/07 33-47-00 401 Nov01/07 33-48-00 406 Feb01/07
33-46-11 427 May01/07 33-47-00 402 Nov01/07 33-48-00 407 Feb01/07
33-46-11 501 May01/06 33-47-00 403 Nov01/07 33-48-00 408 Feb01/07
33-46-11 502 May01/06 33-47-00 404 Nov01/07 33-48-00 409 Feb01/07
33-46-11 503 May01/06 33-47-00 405 Nov01/07 33-48-00 410 Feb01/07
33-46-11 504 May01/06 33-47-00 406 Nov01/07 33-48-00 411 Feb01/07
33-46-11 505 May01/06 33-47-00 407 Nov01/07 33-48-00 412 Feb01/07
33-46-11 506 May01/06 33-47-00 408 Nov01/07 33-48-00 413 May01/06
33-46-11 507 May01/06 33-47-00 409 Nov01/07 33-48-00 414 May01/06
33-46-11 508 May01/06 33-47-00 410 Nov01/07 33-48-00 415 Feb01/07
33-46-11 509 May01/06 33-47-00 411 Nov01/07 33-48-00 416 Feb01/07
33-46-12 401 Feb01/07 33-47-00 412 Nov01/07 33-48-00 417 May01/06
33-46-12 402 Feb01/07 33-47-00 413 Nov01/07 33-48-00 418 May01/06
33-46-12 403 Nov01/99 33-47-00 501 May01/06 33-48-00 501 Aug01/06
33-46-12 404 Nov01/99 33-47-00 502 Aug01/06 33-48-00 502 Aug01/06
33-46-12 405 Feb01/07 33-47-00 503 May01/06 33-48-00 503 Nov01/07
33-46-12 406 Feb01/07 33-47-11 201 Aug01/07 33-48-00 504 Feb01/07
33-46-12 407 Feb01/08 33-47-11 202 Aug01/07 33-48-00 505 Feb01/07
33-46-12 408 Feb01/08 33-47-11 203 Aug01/06 33-48-00 506 Feb01/07
33-46-12 409 Feb01/08 33-47-11 204 Aug01/06 33-48-00 507 Nov01/07
33-46-12 410 Feb01/08 33-47-11 205 Aug01/07 33-48-00 508 Nov01/07
33-46-12 411 Feb01/08 33-47-11 206 Aug01/07 33-48-00 509 Nov01/07
33-46-12 412 Feb01/08 33-47-11 401 Aug01/06 33-48-11 401 Feb01/07
33-46-12 413 Aug01/06 33-47-11 402 Aug01/06 33-48-11 402 Feb01/07
33-46-12 414 Aug01/06 33-47-11 403 Aug01/06 33-48-11 403 Feb01/08
33-46-12 415 Aug01/06 33-47-11 404 Aug01/06 33-48-11 404 Nov01/07
33-46-12 416 Feb01/07 33-47-11 405 Aug01/06 33-48-11 405 Feb01/07
33-46-12 417 May01/07 33-47-11 406 Aug01/06 33-48-11 406 May01/06
33-46-12 418 May01/07 33-47-11 407 Aug01/07 33-48-11 407 Nov01/07
33-46-12 419 May01/07 33-47-11 408 Aug01/07 33-48-11 408 Nov01/07
33-46-12 420 Aug01/06 33-48-11 409 Nov01/07
33-46-12 421 May01/07 33-48-00 1 Feb01/07 33-48-11 410 Nov01/07

33-L.E.P. Page 7
May 01/08

IAC
CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE

33-48-11 411 Nov01/07 33-48-13 411 Nov01/06 33-48-39 407 Aug01/06


33-48-11 412 Nov01/07 33-48-13 412 Nov01/06
33-48-11 413 Nov01/07 33-48-13 413 Nov01/06 33-49-00 1 Feb01/96
33-48-11 414 Nov01/07 33-48-13 414 Nov01/06 33-49-00 2 Feb01/96
33-48-11 415 Nov01/07 33-48-14 401 Feb01/96 33-49-00 3 Feb01/96
33-48-11 416 Nov01/07 33-48-14 402 Aug01/06 33-49-00 401 Feb01/08
33-48-11 417 Nov01/07 33-48-14 403 Feb01/96 33-49-00 402 Feb01/08
33-48-11 418 Nov01/07 33-48-14 404 Feb01/96 33-49-00 403 Feb01/08
33-48-11 419 Nov01/07 33-48-14 405 May01/06 33-49-00 404 May01/05
33-48-11 420 Nov01/07 33-48-14 406 May01/06 33-49-00 405 Aug01/06
33-48-11 421 Nov01/07 33-48-14 407 Feb01/07 33-49-00 501 Aug01/06
33-48-11 422 Nov01/07 33-48-14 408 Feb01/07 33-49-00 502 Aug01/06
33-48-11 423 Nov01/07 33-48-14 409 Aug01/06 33-49-11 401 Feb01/96
33-48-11 424 Nov01/07 33-48-14 410 Aug01/06 33-49-11 402 Aug01/06
33-48-11 425 Nov01/07 33-48-14 411 May01/06 33-49-11 403 Aug01/06
33-48-11 426 Feb01/07 33-48-14 412 Aug01/06 33-49-11 404 Aug01/06
33-48-11 427 Nov01/07 33-48-14 413 Aug01/06 33-49-11 405 Nov01/04
33-48-11 428 Nov01/07 33-48-14 414 Aug01/06 33-49-11 406 Aug01/06
33-48-11 429 Nov01/07 33-48-14 415 May01/06 33-49-11 407 Aug01/06
33-48-11 430 Nov01/07 33-48-14 416 Aug01/06 33-49-11 408 Aug01/06
33-48-12 401 Feb01/07 33-48-14 417 Aug01/06 33-49-11 409 Aug01/07
33-48-12 402 Feb01/07 33-48-14 418 Aug01/06 33-49-11 410 Aug01/07
33-48-12 403 Nov01/07 33-48-14 419 May01/06 33-49-11 411 Aug01/06
33-48-12 404 Nov01/07 33-48-36 401 Aug01/06 33-49-11 412 Feb01/07
33-48-12 405 Aug01/06 33-48-36 402 Aug01/06 33-49-11 413 Feb01/07
33-48-12 406 Nov01/07 33-48-36 403 Aug01/06 33-49-11 414 Aug01/07
33-48-12 407 Feb01/07 33-48-36 404 Aug01/06 33-49-11 415 Feb01/07
33-48-12 408 Nov01/07 33-48-36 405 Aug01/06
33-48-12 409 Nov01/07 33-48-36 406 Aug01/06 33-50-00 1 Feb01/07
33-48-12 410 Nov01/07 33-48-37 401 Aug01/06 33-50-00 2 Feb01/07
33-48-12 411 Feb01/07 33-48-37 402 Aug01/06 33-50-00 3 Feb01/07
33-48-12 412 Aug01/06 33-48-37 403 Feb01/96 33-50-00 4 Feb01/07
33-48-12 413 May01/06 33-48-37 404 Aug01/06 33-50-00 5 Feb01/07
33-48-12 414 May01/06 33-48-37 405 Aug01/06
33-48-12 415 Nov01/07 33-48-37 406 Aug01/06 33-51-00 1 Feb01/07
33-48-12 416 Nov01/07 33-48-37 407 May01/06 33-51-00 2 Feb01/07
33-48-12 417 May01/06 33-48-38 401 May01/06 33-51-00 3 Feb01/07
33-48-12 418 May01/06 33-48-38 402 Aug01/06 33-51-00 4 May01/07
33-48-12 419 Nov01/07 33-48-38 403 Feb01/96 33-51-00 5 May01/07
33-48-12 420 Nov01/07 33-48-38 404 Feb01/96 33-51-00 6 Aug01/07
33-48-12 421 Aug01/06 33-48-38 405 Feb01/96 33-51-00 7 Aug01/07
33-48-13 401 Feb01/07 33-48-38 406 Aug01/06 33-51-00 8 Aug01/07
33-48-13 402 Feb01/07 33-48-38 407 Aug01/06 33-51-00 9 Aug01/07
33-48-13 403 Aug01/06 33-48-38 408 Aug01/06 33-51-00 10 May01/07
33-48-13 404 Feb01/07 33-48-38 409 Aug01/06 33-51-00 11 Aug01/07
33-48-13 405 Feb01/07 33-48-39 401 Aug01/06 33-51-00 12 Aug01/07
33-48-13 406 Feb01/08 33-48-39 402 Aug01/06 33-51-00 13 Aug01/07
33-48-13 407 Feb01/07 33-48-39 403 Feb01/96 33-51-00 14 Aug01/07
33-48-13 408 Feb01/07 33-48-39 404 May01/06 33-51-00 15 Aug01/07
33-48-13 409 Feb01/07 33-48-39 405 Aug01/06 33-51-00 16 Aug01/07
33-48-13 410 Nov01/06 33-48-39 406 Aug01/06 33-51-00 17 Aug01/07

33-L.E.P. Page 8
May 01/08

IAC
CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE

33-51-00 18 Aug01/07 33-51-00 69 Aug01/07 33-51-00 528 Nov01/07


33-51-00 19 Aug01/07 33-51-00 70 Aug01/07 33-51-00 529 Nov01/07
33-51-00 20 Aug01/07 33-51-00 71 Aug01/07 33-51-00 530 Nov01/07
33-51-00 21 Aug01/07 33-51-00 72 Aug01/07 33-51-00 531 Nov01/07
33-51-00 22 Aug01/07 33-51-00 73 Aug01/07 33-51-00 532 Nov01/07
33-51-00 23 Aug01/07 33-51-00 74 Aug01/07 33-51-00 533 Nov01/07
33-51-00 24 Aug01/07 33-51-00 75 Aug01/07 33-51-00 534 Nov01/07
33-51-00 25 Aug01/07 33-51-00 76 Aug01/07 33-51-00 535 Nov01/07
33-51-00 26 Aug01/07 33-51-00 77 Aug01/07 33-51-00 536 Nov01/07
33-51-00 27 Aug01/07 33-51-00 78 Aug01/07 33-51-00 537 Nov01/07
33-51-00 28 Aug01/07 33-51-00 79 Aug01/07 33-51-00 538 Nov01/07
33-51-00 29 Aug01/07 33-51-00 80 Aug01/07 33-51-00 539 Nov01/07
33-51-00 30 Aug01/07 33-51-00 81 Aug01/07 33-51-00 540 Nov01/07
33-51-00 31 May01/07 33-51-00 82 Aug01/07 33-51-00 541 Nov01/07
33-51-00 32 May01/07 33-51-00 401 Nov01/07 33-51-00 542 Nov01/07
33-51-00 33 May01/07 33-51-00 402 Nov01/07 33-51-00 543 Nov01/07
33-51-00 34 May01/07 33-51-00 403 Nov01/07 33-51-00 544 Nov01/07
33-51-00 35 May01/07 33-51-00 404 Nov01/07 33-51-00 545 Nov01/07
33-51-00 36 May01/07 33-51-00 405 Nov01/07 33-51-00 546 Nov01/07
33-51-00 37 May01/07 33-51-00 406 Nov01/07 33-51-00 547 Nov01/07
33-51-00 38 May01/07 33-51-00 407 Aug01/07 33-51-00 548 Nov01/07
33-51-00 39 May01/07 33-51-00 408 Aug01/07 33-51-00 549 Nov01/07
33-51-00 40 May01/07 33-51-00 409 Aug01/07 33-51-00 550 Nov01/07
33-51-00 41 May01/07 33-51-00 410 Aug01/07 33-51-00 551 Nov01/07
33-51-00 42 Aug01/07 33-51-00 501 Nov01/07 33-51-00 552 Nov01/07
33-51-00 43 Aug01/07 33-51-00 502 Nov01/07 33-51-00 553 Nov01/07
33-51-00 44 Aug01/07 33-51-00 503 Nov01/07 33-51-00 554 Nov01/07
33-51-00 45 May01/07 33-51-00 504 Nov01/07 33-51-00 555 Nov01/07
33-51-00 46 May01/07 33-51-00 505 Nov01/07 33-51-00 556 Nov01/07
33-51-00 47 Aug01/07 33-51-00 506 Nov01/07 33-51-00 557 Nov01/07
33-51-00 48 Aug01/07 33-51-00 507 Nov01/07 33-51-00 558 Nov01/07
33-51-00 49 Aug01/07 33-51-00 508 Nov01/07 33-51-00 559 Nov01/07
33-51-00 50 Aug01/07 33-51-00 509 Nov01/07 33-51-00 560 Nov01/07
33-51-00 51 Aug01/07 33-51-00 510 Nov01/07 33-51-00 561 Nov01/07
33-51-00 52 Aug01/07 33-51-00 511 Nov01/07 33-51-00 562 Nov01/07
33-51-00 53 Aug01/07 33-51-00 512 Nov01/07 33-51-11 401 Aug01/07
33-51-00 54 Aug01/07 33-51-00 R 513 May01/08 33-51-11 402 Aug01/07
33-51-00 55 Aug01/07 33-51-00 R 514 May01/08 33-51-11 403 Aug01/07
33-51-00 56 Aug01/07 33-51-00 515 Nov01/07 33-51-11 404 Aug01/07
33-51-00 57 Feb01/08 33-51-00 516 Nov01/07 33-51-11 405 Aug01/07
33-51-00 58 Feb01/08 33-51-00 517 Nov01/07 33-51-11 406 Feb01/07
33-51-00 59 Aug01/07 33-51-00 518 Nov01/07 33-51-11 407 Feb01/07
33-51-00 60 Aug01/07 33-51-00 519 Nov01/07 33-51-11 408 Aug01/07
33-51-00 61 Aug01/07 33-51-00 520 Nov01/07 33-51-11 409 Aug01/07
33-51-00 62 Aug01/07 33-51-00 521 Nov01/07 33-51-11 R 410 May01/08
33-51-00 63 Feb01/08 33-51-00 522 Nov01/07 33-51-11 R 411 May01/08
33-51-00 64 Feb01/08 33-51-00 523 Nov01/07 33-51-11 412 Aug01/07
33-51-00 65 Aug01/07 33-51-00 524 Nov01/07 33-51-11 413 Aug01/07
33-51-00 66 Aug01/07 33-51-00 525 Nov01/07 33-51-11 414 Aug01/07
33-51-00 67 Aug01/07 33-51-00 526 Nov01/07 33-51-11 415 Aug01/07
33-51-00 68 Aug01/07 33-51-00 527 Nov01/07 33-51-11 416 Aug01/07

33-L.E.P. Page 9
May 01/08

IAC
CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE

33-51-11 417 Aug01/07 33-51-14 426 May01/06 33-51-19 401 May01/06


33-51-11 418 Aug01/07 33-51-14 427 May01/06 33-51-19 402 May01/06
33-51-11 419 Aug01/07 33-51-14 428 May01/06 33-51-19 403 May01/06
33-51-11 420 Aug01/07 33-51-14 429 May01/07 33-51-19 404 May01/06
33-51-11 421 Aug01/07 33-51-14 430 Aug01/07 33-51-19 405 May01/06
33-51-11 422 Aug01/07 33-51-14 431 May01/07 33-51-19 406 May01/06
33-51-11 423 Aug01/07 33-51-14 432 May01/07 33-51-21 401 Aug01/07
33-51-11 424 Aug01/07 33-51-14 433 May01/07 33-51-21 402 Aug01/07
33-51-11 425 Aug01/07 33-51-14 434 May01/07 33-51-21 403 Aug01/06
33-51-11 426 Aug01/07 33-51-14 435 Aug01/07 33-51-21 404 May01/07
33-51-11 427 Feb01/08 33-51-14 436 Aug01/07 33-51-21 405 May01/07
33-51-11 428 Aug01/07 33-51-15 401 Feb01/07 33-51-21 406 May01/07
33-51-13 401 Aug01/07 33-51-15 402 Aug01/07 33-51-21 407 May01/07
33-51-13 402 Aug01/07 33-51-15 403 Aug01/07 33-51-21 408 Aug01/07
33-51-13 403 Aug01/07 33-51-15 404 Feb01/07 33-51-21 409 Aug01/07
33-51-13 404 May01/07 33-51-15 405 Aug01/07 33-51-21 410 May01/07
33-51-13 405 May01/07 33-51-15 406 Aug01/07 33-51-21 411 Aug01/07
33-51-13 406 Aug01/07 33-51-15 407 Aug01/07 33-51-21 412 Aug01/07
33-51-13 407 Aug01/07 33-51-15 408 Aug01/07 33-51-21 413 Aug01/07
33-51-13 408 Aug01/07 33-51-15 409 Aug01/07 33-51-21 414 Aug01/07
33-51-13 409 May01/07 33-51-15 410 Aug01/07 33-51-21 701 Feb01/07
33-51-13 410 Aug01/07 33-51-16 401 Feb01/07 33-51-21 702 Feb01/07
33-51-13 411 Aug01/07 33-51-16 402 Aug01/07 33-51-21 703 Feb01/07
33-51-13 412 Aug01/07 33-51-16 403 Aug01/07 33-51-38 401 Feb01/07
33-51-13 413 Aug01/07 33-51-16 404 Aug01/07 33-51-38 402 Aug01/07
33-51-13 414 Aug01/07 33-51-16 405 Aug01/07 33-51-38 403 Aug01/07
33-51-14 401 May01/06 33-51-16 406 Aug01/07 33-51-38 404 May01/07
33-51-14 402 May01/06 33-51-16 407 Aug01/07 33-51-38 405 May01/07
33-51-14 403 Feb01/96 33-51-16 408 Aug01/07 33-51-38 406 May01/07
33-51-14 404 May01/03 33-51-16 409 Aug01/07 33-51-38 407 May01/07
33-51-14 405 May01/06 33-51-16 410 Aug01/07 33-51-38 408 May01/07
33-51-14 406 May01/06 33-51-16 411 Aug01/07 33-51-38 409 Feb01/07
33-51-14 407 May01/06 33-51-16 412 Aug01/07 33-51-38 410 May01/07
33-51-14 408 May01/06 33-51-17 401 Feb01/07 33-51-38 411 May01/07
33-51-14 409 May01/06 33-51-17 402 Aug01/07 33-51-38 412 Aug01/07
33-51-14 410 May01/06 33-51-17 403 Aug01/07 33-51-38 413 Aug01/07
33-51-14 411 May01/06 33-51-17 404 May01/07 33-51-38 414 Aug01/07
33-51-14 412 Feb01/96 33-51-17 405 Feb01/07 33-51-38 415 Aug01/07
33-51-14 413 May01/03 33-51-17 406 Feb01/07 33-51-38 416 Aug01/07
33-51-14 414 May01/03 33-51-17 407 May01/07 33-51-38 417 May01/07
33-51-14 415 May01/06 33-51-17 408 May01/07 33-51-38 418 May01/07
33-51-14 416 May01/06 33-51-17 409 Aug01/07 33-51-38 419 May01/07
33-51-14 417 May01/06 33-51-17 410 May01/07 33-51-38 420 May01/07
33-51-14 418 May01/06 33-51-17 411 May01/07 33-51-38 421 May01/07
33-51-14 419 May01/06 33-51-17 412 May01/07 33-51-38 422 May01/07
33-51-14 420 May01/06 33-51-18 401 May01/06 33-51-38 423 Aug01/07
33-51-14 421 Nov01/06 33-51-18 402 May01/06 33-51-38 424 Aug01/07
33-51-14 422 Feb01/96 33-51-18 403 May01/06 33-51-38 425 May01/07
33-51-14 423 May01/03 33-51-18 404 May01/06 33-51-38 426 May01/07
33-51-14 424 Nov01/06 33-51-18 405 May01/06 33-51-38 427 May01/07
33-51-14 425 May01/06 33-51-18 406 May01/06 33-51-38 428 May01/07

33-L.E.P. Page 10
May 01/08

IAC
CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE CH/SE/SU C PAGE DATE

33-51-38 429 May01/07


33-51-38 430 Aug01/07
33-51-38 431 Aug01/07
33-51-38 432 Aug01/07
33-51-38 433 Aug01/07
33-51-38 434 Aug01/07
33-51-38 435 Aug01/07
33-51-38 436 Aug01/07
33-51-38 437 Aug01/07
33-51-38 438 Aug01/07
33-51-38 439 Aug01/07

33-L.E.P. Page 11
May 01/08

IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT ________
CH/SE/SU C
_ PAGE ___________
____ EFFECTIVITY
LIGHTS - GENERAL
________________ 33-00-00
DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Cockpit Lights 1 ALL
Cabin Lights 1 ALL
Cargo and Service Compartment 1 ALL
Lights
External Lights 1 ALL
Cabin Emergency Lighting 2 ALL

_______
COCKPIT 33-10-00
DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Power Supply 1 ALL

GENERAL ILLUMINATION 33-12-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Component Location 1 ALL
System Description 7 ALL
Cockpit Lighting by Dome Lights 7 ALL
Console Lighting 9 ALL
Instrument Panel Lighting 9 ALL
Reading Lights 19 ALL
Cockpit Outlets 21 ALL

GENERAL ILLUMINATION 33-12-00


ADJUSTMENT/TEST 501 ALL
Operational Test of the General 501 ALL
Illumination
LIGHT - DOME, COCKPIT 33-12-11
REMOVAL/INSTALLATION 401 ALL
Removal of the Cockpit Dome Light 401 ALL
(161LE, 162LE, 163LE, 164LE,
165LE, 166LE, 167LE, 168LE)
Installation of the Cockpit Dome 405 ALL
Light (161LE, 162LE, 163LE, 164LE,
165LE, 166LE, 167LE, 168LE)
LIGHT - READING 33-12-12
REMOVAL/INSTALLATION 1 401 001-012, 014-027
Removal of the Reading Light 401 001-012, 014-027
(25LE, 26LE, 29LE)
Installation of the Reading Light 408 001-012, 014-027
(25LE, 26LE, 29LE)
LIGHT - MAP TABLE 33-12-12

33-CONTENTS Page 1
May 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT CH/SE/SU
________ _
C ____ EFFECTIVITY
PAGE ___________
REMOVAL/INSTALLATION 2 401 028-099, 101-199
901-999,
Removal of the Map Table Lights 401 028-099, 101-199
(41LE, 42LE) 901-999,
Installation of the Map Table 404 028-099, 101-199
lights (41LE, 42LE) 901-999,
LIGHT - MAIN AND CENTER INSTRUMENT 33-12-13
PANEL
REMOVAL/INSTALLATION 401 ALL
Removal of the Main 401 ALL
Instrument-Panel Lights (36LE,
37LE)
Installation of the Main 406 ALL
Instrument-Panel Light (36LE,
37LE)
Removal of the Main 410 ALL
Instrument-Panel Center-Light
(38LE)
Installation of the Main 413 ALL
Instrument-Panel Center-Light
(38LE)
LIGHT - CENTER PEDESTAL 33-12-14
REMOVAL/INSTALLATION 401 ALL
Removal of the Center Pedestal 401 ALL
Light (27LE)
Installation of the Center 406 ALL
Pedestal Light (27LE)
LIGHT - CONSOLE AND BRIEFCASE 33-12-15
REMOVAL/INSTALLATION 401 ALL
Removal of the Console and 401 ALL
Briefcase Light (17LE, 18LE, 19LE,
20LE, 21LE, 22LE, 23LE, 24LE)
Installation of the Console and 404 ALL
Briefcase Light (17LE, 18LE, 19LE,
20LE, 21LE, 22LE, 23LE, 24LE)
RHEOSTAT - FLOODLIGHT 33-12-17
REMOVAL/INSTALLATION 401 ALL
Removal of the Rheostat - Flood 401 ALL
Light (28LE, 35LE)
Installation of the Rheostat - 405 ALL
Flood Light (28LE, 35LE)
RHEOSTAT - MAP TABLE LIGHT 33-12-18
REMOVAL/INSTALLATION 401 028-099, 101-199
901-999,
Removal of the Map Table Light 401 028-099, 101-199
Rheostats (39LE, 40LE) 901-999,

33-CONTENTS Page 2
Feb 01/07
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT CH/SE/SU
________ C
_ ____ EFFECTIVITY
PAGE ___________
Installation of the Map Table 406 028-099, 101-199
Light Rheostats (39LE, 40LE) 901-999,

INSTRUMENT AND PANEL INTEGRAL LIGHTING 33-13-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Component Location 1 ALL
System Description 3 ALL
Instrument and Panel Integral 3 ALL
Lighting
Standby Compass Lighting 5 ALL

INSTRUMENT AND PANEL INTEGRAL LIGHTING 33-13-00


ADJUSTMENT/TEST 501 ALL
Operational Test of the Instrument 501 ALL
and Panel Integral Lighting
PLATE - INT LIGHTED IDENT, 11VU 33-13-41
REMOVAL/INSTALLATION 401 ALL
Removal of the Integrally-Lighted 401 ALL
Identification Plate
Installation of the 407 ALL
Integrally-Lighted Identification
Plate
PLATE - INT LIGHTED IDENT, 20VU 33-13-42
REMOVAL/INSTALLATION 401 ALL
Removal of the Integrally-Lighted 401 ALL
Identification Plate
Installation of the 405 ALL
Integrally-Lighted Identification
Plate
CONTROLLER - LIGHTING 33-13-51
REMOVAL/INSTALLATION 401 ALL
Removal of the Lighting Controller 401 ALL
(6LF, 16LF, 30LF)
Installation of the Lighting 405 ALL
Controller (6LF, 16LF, 30LF)

ANNUNCIATOR LIGHT TEST AND DIMMING 33-14-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Component Location 1 ALL
System Description 5 ALL
Four Identical Transformers 8 ALL
Five Circuit Breakers 8 ALL
Switch 33LP 8 ALL

33-CONTENTS Page 3
Feb 01/07
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

SUBJECT
_______ CH/SE/SU
________ C
_ ____ ___________
PAGE EFFECTIVITY
Fourteen Annunciator Light Test 8 ALL
and Interface Boards
Four-Stage Relays 9 ALL
Operational/Control and Indicating 9 ALL
Annunciator Light Test for the 9 ALL
External Power Panel 108VU

ANNUNCIATOR LIGHT TEST AND DIMMING 33-14-00


ADJUSTMENT/TEST 501 ALL
Operational Test of the Lights 501 ALL
BOARD - ANNUNCIATOR LIGHT TEST AND 33-14-33
INTERFACE
REMOVAL/INSTALLATION 401 ALL
Removal of the Annunciator-Light 401 ALL
Test and Interface-Board (1LP,
2LP, 3LP, 4LP, 5LP, 6LP, 7LP, 8LP,
9LP, 10LP, 11LP, 12LP, 18LP, 19LP,
20LP)
Installation of the 406 ALL
Annunciator-Light Test and
Interface-Board (1LP, 2LP, 3LP,
4LP, 5LP, 6LP, 7LP, 8LP, 9LP,
10LP, 11LP, 12LP, 18LP, 19LP,
20LP)
TRANSFORMER - ANNUNCIATOR LIGHT TEST 33-14-51
REMOVAL/INSTALLATION 401 ALL
Removal of the Essential 401 ALL
Transformers (31LP, 35LP)
Removal of the System 1 (2) 404 ALL
Transformer (37LP, 36LP)
Installation of the Essential 407 ALL
Transformers (31LP, 35LP)
Installation of the System 1 (2) 410 ALL
Transformer (37LP, 36LP)

_____
CABIN 33-20-00
DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Description 1 ALL
General Illumination 1 ALL
Lavatory Lighting 1 ALL
Passenger Reading Lights 4 ALL
Lavatory Lighted Signs 4 ALL
Cabin Attendant Work-Lights 4 ALL

33-CONTENTS Page 4
Aug 01/07
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

SUBJECT
_______ CH/SE/SU
________ C
_ PAGE ___________
____ EFFECTIVITY

______
CABIN 33-20-00
DEACTIVATION/REACTIVATION 401 ALL
Deactivation of the Cabin NO 401 ALL
SMOKING / FASTEN SEAT BELTS /
RETURN TO SEAT (NS/FSB/RTS) Signs
Refer to the MMEL TASK: 33-20-02 401 ALL
b)
Reactivation of the Cabin NO 403 ALL
SMOKING / FASTEN SEAT BELTS /
RETURN TO SEAT (NS/FSB/RTS) Signs
Refer to the MMEL TASK: 33-20-02 403 ALL
b)

GENERAL ILLUMINATION 33-21-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Passenger Cabin Lighting 1 001-012, 014-099
Entrance Area Lighting 1 001-012, 014-099
Passenger Cabin Lighting 1 101-199, 901-999
Entrance Area Lighting 2 101-199, 901-999
Component Location 20 ALL
System Description 29 ALL
Cabin Illumination 29 001-012, 014-099
Forward Attendant Panel (FAP) 29 001-012, 014-099
Cabin Illumination 30 101-199, 901-999
Flight Attendant Panel (FAP) 31 101-199, 901-999
120RH
Additional Attendant Panel (AAP) 32 101-199, 901-999
Component Description 32 ALL
Lamp and Ballast Unit 32 001-012, 014-099
Fluorescent Lamp, Advanced 34 101-199, 901-999
Integrated Ballast-Units (AIBUs)
and Stand Alone - Passenger
Interface and Supply Adapter
(StA-PISA)
Stand Alone - Passenger 34 101-199, 901-999
Interface and Supply Adapter
(StA-PISA)
Operation/Control and Indication 34 ALL
Entrance Lighting 36 ALL

GENERAL ILLUMINATION 33-21-00


ADJUSTMENT/TEST 501 ALL
Operational Test of the General 501 ALL

33-CONTENTS Page 5
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT CH/SE/SU
________ C
_ PAGE ___________
____ EFFECTIVITY
Illumination
Bite Test of the General 522 101-199, 901-999
Illumination with the MCDU
BALLAST UNIT WITH LAMPHOLDER 33-21-11
REMOVAL/INSTALLATION 401 ALL
Removal of the Ballast Unit and 401 ALL
Lampholder 1LG1 (3LG1)
Installation of the Ballast Unit 408 ALL
and Lampholder 1LG1
SWITCH - CABIN ENTRANCE LIGHT DIMMING 33-21-12
REMOVAL/INSTALLATION 401 ALL
Removal of the Cabin Entrance 401 ALL
Light Dimming Switch (310LG)
Installation of the Cabin Entrance 404 ALL
Light Dimming Switch (310LG)

CALL SYSTEM (SEE ALSO 23-73-00) 33-23-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL

LAVATORY LIGHTING 33-24-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Description 1 001-012, 014-099
The lavatory lighting system has 1 101-199, 901-999
a fluorescent lamp, an
integrated ballast unit and a
halogen lamp installed in each
lavatory.
Component Location 1 ALL
System Description 3 ALL
Power Supply 6 ALL
Operation 11 ALL
Component Operation 11 001-012, 014-099
Component Operation 11 101-199, 901-999

LAVATORY LIGHTING 33-24-00


ADJUSTMENT/TEST 501 ALL
Operational Test of the Lavatory 501 ALL
Lighting LQ
BALLAST UNIT WITH LAMPHOLDER 33-24-11
REMOVAL/INSTALLATION 401 ALL
Removal of the Ballast Unit and 401 001-012, 014-099
Lampholder 3LQ
Installation of the Ballast Unit 404 001-012, 014-099

33-CONTENTS Page 6
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT CH/SE/SU
________ C
_ PAGE ___________
____ EFFECTIVITY
and Lampholder 3LQ
Removal of the Ballast Unit and 407 001-012, 014-099
Lampholder 4LQ
Installation of the Ballast Unit 410 001-012, 014-099
and Lampholder 4LQ
Removal of the Ballast Unit and 413 001-012, 014-099
Lampholder 6LQ
Installation of the Ballast Unit 416 001-012, 014-099
and Lampholder 6LQ
Removal of the Ballast Unit and 419 101-199, 901-999
Lampholder
Installation of the Ballast Unit 424 101-199, 901-999
and Lampholder
HALOGEN LAMP WITH LAMPHOLDER 33-24-12
REMOVAL/INSTALLATION 401 101-199, 901-999
Removal of the Mirror Lavatory 401 101-199, 901-999
Light
Installation of the Mirror 402 101-199, 901-999
Lavatory Light

PASSENGER READING LIGHTS 33-25-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Component Location 1 ALL
System Description 11 ALL
Power Supply 18 ALL
Operation 18 ALL
Component Description 19 001-012, 014-099
Component Description 20 101-199, 901-999

PASSENGER READING LIGHTS 33-25-00


ADJUSTMENT/TEST 501 ALL
Operational test of the Passenger 501 ALL
Reading Light System
Adjustment of the Passenger 507 ALL
Reading Lights

LAVATORY LIGHTED SIGNS 33-26-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Component Location 1 ALL
System Description 4 ALL
Occupied Sign of the Forward 4 ALL
Lavatory A
Rear Lavatory Occupied-Signs 14 001-012, 014-099

33-CONTENTS Page 7
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

SUBJECT
_______ CH/SE/SU
________ C
_ ____ ___________
PAGE EFFECTIVITY
Rear Lavatory Occupied-Signs 15 101-199,
Rear Lavatory Occupied-Signs 16 901-999,

LAVATORY LIGHTED SIGNS 33-26-00


ADJUSTMENT/TEST 501 ALL
Operational Test of the Lavatory 501 ALL
Lighted Signs WJ
MICRO SWITCH - LAVATORY OCCUPIED 33-26-11
REMOVAL/INSTALLATION 401 ALL
Removal of the Lavatory Door 401 ALL
Microswitch (WJ)
Installation of the Lavatory Door 407 ALL
Microswitch (WJ)
SIGN - LAVATORY OCCUPIED 33-26-23
REMOVAL/INSTALLATION 401 ALL
Removal of the Lavatory Occupied 401 ALL
Signs (WJ)
Installation of the Lavatory 408 ALL
Occupied Signs (WJ)

LIGHT - WORK, CABIN ATTENDANT 33-27-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Component Location 1 ALL
System Description 4 ALL
Cabin Attendant Work-Light 4 001-012, 014-099
Cabin Attendant Work-Light 6 101-199, 901-999
Component Description 6 ALL
Cabin Attendant Work-Light 6 001-012, 014-099
The system of the cabin 8 101-199, 901-999
attendant work-lights give
lighting to each attendant seat
independently. The Passenger
Interface and Supply Adapters

LIGHT - WORK, CABIN ATTENDANT 33-27-00


ADJUSTMENT/TEST 501 ALL
Operational Test of the Cabin 501 ALL
Attendant Work-Light
Bite Test of the Cabin Attendant 510 ALL
Work-Light through MCDU
LIGHT - WORK, CABIN ATTENDANT 33-27-12
REMOVAL/INSTALLATION 401 ALL
Removal of the Cabin Attendant 401 ALL

33-CONTENTS Page 8
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT CH/SE/SU
________ C
_ PAGE ___________
____ EFFECTIVITY
Work-Lights
Installation of the Cabin 408 ALL
Attendant Work-Lights
POWER UNIT - CABIN ATTENDANT WORK 33-27-38
LIGHT
REMOVAL/INSTALLATION 401 001-012, 014-099
Removal of the Power Unit for the 401 001-012, 014-099
Cabin Attendant Work-Light
Installation of the Power Unit for 404 001-012, 014-099
the Cabin Attendant Work-Light
PISA (PASSENGER INTERFACE AND SUPPLY 33-27-41
ADAPTER) - STAND ALONE
REMOVAL/INSTALLATION 401 101-199, 901-999
Removal of the Stand-Alone 401 101-199, 901-999
Passenger Interface and Supply
Adapter (StA-PISA)
Installation of the Stand-Alone 407 101-199, 901-999
Passenger Interface and Supply
Adapter (StA-PISA)

______________________________
CARGO AND SERVICE COMPARTMENTS 33-30-00
DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
System Description 1 ALL
Service Area Lighting 1 ALL
Air Conditioning Duct and 1 ALL
Accessory Compartment
Forward and Aft 4 ALL
Cargo-Compartment Lighting
Avionics Compartment Lighting 4 ALL
Wheel Well Lighting 4 ALL

SERVICE AREA LIGHTING 33-31-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Component Location 1 ALL
System Description 1 ALL

SERVICE AREA LIGHTING 33-31-00


ADJUSTMENT/TEST 501 ALL
Operational Test of the Service 501 ALL
Area Lighting
Functional Test of the Maintenance 505 ALL
Sockets
LIGHT - SERVICE AREA 33-31-11

33-CONTENTS Page 9
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT CH/SE/SU
________ C
_ ____ ___________
PAGE EFFECTIVITY
REMOVAL/INSTALLATION 401 ALL
Removal of the Service Area Light 401 ALL
6LJ
Installation of the Service Area 407 ALL
Light 6LJ
Removal of the Service Area Light 413 ALL
4LJ (5LJ)
Installation of the Service Area 419 ALL
Light 4LJ (5LJ)
Removal of the Lamp of the Service 424 101-199, 901-999
Area Light 6LJ
Installation of the Lamp of the 427 101-199, 901-999
Service Area Light 6LJ
Removal of the Lamp of the Service 430 101-199, 901-999
Area Light 4LJ (5LJ)
Installation of the Lamp of the 433 101-199, 901-999
Service Area Light 4LJ (5LJ)

AIR CONDITIONING DUCT AND ACCESSORY 33-32-00


COMPARTMENT LIGHTING
DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Component Location 1 ALL
System Description 1 ALL

AIR CONDITIONING DUCT AND ACCESSORY 33-32-00


COMPARTMENT LIGHTING
ADJUSTMENT/TEST 501 ALL
Functional Test of the Maintenance 501 ALL
Socket in the Air Conditioning
Duct and Accessory Compartment
(LK)

FWD - AFT CARGO COMPARTMENT LIGHTING 33-34-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Component Location 1 ALL
System Description 5 ALL

FWD - AFT CARGO COMPARTMENT LIGHTING 33-34-00


ADJUSTMENT/TEST 501 ALL
Operational Test of the FWD and 501 ALL
AFT Cargo Compartment Lighting
BALLAST UNIT WITH LAMPHOLDER 33-34-11

33-CONTENTS Page 10
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT CH/SE/SU
________ C
_ ____ ___________
PAGE EFFECTIVITY
SERVICING 301 ALL
Servicing of the Ballast Units 301 ALL
with Lampholders
BALLAST UNIT WITH LAMPHOLDER 33-34-11
REMOVAL/INSTALLATION 401 ALL
Removal of the Ballast Unit and 401 ALL
Lampholder
Installation of the Ballast Unit 410 ALL
and Lampholder
LIGHT - LOADING AREA 33-34-12
REMOVAL/INSTALLATION 401 ALL
Removal of the Loading-Area Light 401 ALL
(11LU, 12LU)
Installation of the Loading-Area 408 ALL
Light (11LU, 12LU)

AVIONICS COMPARTMENT LIGHTING 33-35-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Component Location 1 ALL
System Description 4 ALL
Operation/Control and Indicating 4 ALL
Auto Mode 4 ALL
Manual Mode 4 ALL

AVIONICS COMPARTMENT LIGHTING 33-35-00


ADJUSTMENT/TEST 501 ALL
Functional Test of the 501 ALL
Avionics-Compartment Lighting
LIGHT - DOME, AVIONICS COMPARTMENT 33-35-11
REMOVAL/INSTALLATION 401 ALL
Removal of the 401 ALL
Avionics-Compartment Dome Lights
(6LS, 7LS, 8LS, 9LS, 10LS, 22LS)
Installation of the 407 ALL
Avionics-Compartment Dome Lights
(6LS, 7LS, 8LS, 9LS, 10LS, 22LS)

WHEEL WELL LIGHTING 33-37-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Component Location 1 ALL
System Description 1 ALL

33-CONTENTS Page 11
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT ________
CH/SE/SU C
_ PAGE ___________
____ EFFECTIVITY
WHEEL WELL LIGHTING 33-37-00
ADJUSTMENT/TEST 501 ALL
Operational Test of the Wheel Well 501 ALL
Lighting
Functional Test of the Maintenance 506 ALL
Sockets
LIGHT - DOME, MLG L AND R WELL 33-37-11
REMOVAL/INSTALLATION 401 ALL
Removal of the MLG Dome Light 401 001-012, 014-099
(HELLA)
Installation of the MLG Dome Light 407 001-012, 014-099
(HELLA)
Removal of the Lamp(s) of the MLG 411 ALL
Dome Light (AIRSIGNA)
Installation of the Lamp(s) of the 417 ALL
MLG Dome Light (AIRSIGNA)
Removal of the MLG Dome Light 423 ALL
(AIRSIGNA)
Installation of the MLG Dome Light 429 ALL
(AIRSIGNA)

________
EXTERIOR 33-40-00
DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
System Description 1 ALL
Taxi and Takeoff Lights 1 ALL
Runway Turnoff Lights 1 ALL
Wing and Engine Scan Lights 1 ALL
Navigation Light 1 ALL
Landing Lights 8 ALL
Anticollision/Beacon Lights 8 ALL
Logo Lights 8 ALL

NAVIGATION LIGHTS 33-41-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Component Location 1 ALL
System Description 1 ALL
Power Supply 1 ALL
Interface 1 ALL
Component Description 4 ALL
Forward-Facing Navigation Light 4 ALL
9LA(10LA)
Rearwards-Facing Navigation 4 ALL
Light 15LA
Operation/Control and Indicating 4 ALL

33-CONTENTS Page 12
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

SUBJECT
_______ CH/SE/SU
________ C
_ PAGE ___________
____ EFFECTIVITY

NAVIGATION LIGHTS 33-41-00


DEACTIVATION/REACTIVATION 401 ALL
Deactivation of the Glazing Panel 401 ALL
of the Wing-Tip Navigation Light
Refer to the CDL TASK: 33-6 401 ALL
Reactivation of the Glazing Panel 410 ALL
of the Wing-Tip Navigation Light
Refer to the CDL TASK: 33-6 410 ALL
Deactivation of the Lens of the 414 ALL
Tail Navigation Light
Refer to the CDL TASK: 33-3 414 ALL
Reactivation of the Lens of the 417 ALL
Tail Navigation Light
Refer to the CDL TASK: 33-3 417 ALL

NAVIGATION LIGHTS 33-41-00


ADJUSTMENT/TEST 501 ALL
Operational Test of the Navigation 501 ALL
Lights
LIGHT - NAVIGATION 33-41-11
REMOVAL/INSTALLATION 401 ALL
Removal of the Wingtip Navigation 401 ALL
Light 9LA(10LA)
Installation of the Wingtip 405 ALL
Navigation Light 9LA(10LA)
Removal of the Lamp in the Wingtip 410 ALL
Navigation Light
Installation of the Lamp in the 414 ALL
Wingtip Navigation Light
LIGHT - NAVIGATION, TAIL 33-41-15
REMOVAL/INSTALLATION 401 ALL
Removal of the Tail Navigation 401 ALL
Light 15LA
Installation of the Tail 404 ALL
Navigation Light 15LA
Removal of the Lamp(s) of the Tail 408 ALL
Navigation Light 15LA
Installation of the Lamp(s) of the 411 ALL
Tail Navigation Light 15LA
TRANSFORMER - TAIL NAVIGATION LIGHT 33-41-16
REMOVAL/INSTALLATION 401 ALL
Removal of the Tail 401 ALL
Navigation-Light Transformer 13LA

33-CONTENTS Page 13
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT CH/SE/SU
________ C
_ ____ ___________
PAGE EFFECTIVITY
Installation of the Tail 404 ALL
Navigation-Light Transformer 13LA

LANDING LIGHTS 33-42-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Component Location 1 ALL
System Description 1 ALL
Power Supply 1 ALL
Interface 1 ALL
Component Description 4 ALL
Landing Light Assembly 7LB(8LB) 4 ALL
Two toggle switches 5LB and 6LB 4 ALL
Operation/Control and Indicating 4 ALL
Two control switches 5LB and 6LB 4 ALL
are installed on the overhead
panel 25VU. The switch LAND L
controls the left-hand landing
light and the

LANDING LIGHTS 33-42-00


DEACTIVATION/REACTIVATION 401 ALL
Deactivation of the Landing Lights 401 ALL
Refer to the CDL TASK: 33-7 401 ALL
Reactivation of the Landing Lights 406 ALL
Refer to the CDL TASK: 33-7 406 ALL

LANDING LIGHTS 33-42-00


ADJUSTMENT/TEST 501 ALL
Operational Test of the Landing 501 ALL
Lights
Adjustment of the Extension Angle 505 001-012, 014-019
of the Landing Lights
LIGHT - LANDING 33-42-11
REMOVAL/INSTALLATION 401 ALL
Removal of the Landing Light 7LB 401 ALL
(8LB)
Installation of the Landing Light 406 ALL
7LB (8LB)
Removal of the Landing Light Lamp 412 ALL
Installation of the Landing Light 417 ALL
Lamp

RUNWAY TURNOFF LIGHTS 33-43-00

33-CONTENTS Page 14
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT CH/SE/SU
________ C
_ ____ ___________
PAGE EFFECTIVITY
DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Component Location 1 ALL
Description 1 ALL
Operation 1 ALL

RUNWAY TURNOFF LIGHTS 33-43-00


DEACTIVATION/REACTIVATION 401 ALL
Deactivation of the Runway Turnoff 401 ALL
Light (3LC1, 3LC2)
Refer to the CDL TASK: 33-8 401 ALL
Reactivation of the Runway Turnoff 404 ALL
Light (3LC1, 3LC2)
Refer to the CDL TASK: 33-8 404 ALL

RUNWAY TURNOFF LIGHTS 33-43-00


ADJUSTMENT/TEST 501 ALL
Operational Test of the Runway 501 ALL
Turnoff Lights
LIGHT - RUNWAY TURNOFF 33-43-11
REMOVAL/INSTALLATION 401 ALL
Removal of the Runway Turnoff 401 ALL
Light (3LC1, 3LC2)
Installation of the Runway Turnoff 404 ALL
Light (3LC1, 3LC2)
Replacement of the Lamp of the 407 ALL
Runway Turnoff Light (3LC1, 3LC2)
Replacement of the Halogen Bulb of 414 ALL
the Runway Turnoff Light (3LC1,
3LC2)
Replacement of the Lens and the 419 ALL
mirror of the Runway Turnoff Light
(3LC1, 3LC2)
LIGHT - RUNWAY TURNOFF 33-43-11
ADJUSTMENT/TEST 501 001-012, 014-099
Adjustment of the Runway Turnoff 501 001-012, 014-099
Light (3LC1, 3LC2)
Adjustment of the Runway Turnoff 505 001-012, 014-099
Light (3CL1, 3CL2) - Alternative
Procedure

TAXI AND TAKE OFF LIGHTS 33-46-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL

33-CONTENTS Page 15
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT CH/SE/SU
________ C
_ ____ ___________
PAGE EFFECTIVITY
Component Location 1 ALL
System Description 1 ALL
Operation/Control and Indicating 1 ALL

TAXI AND TAKE OFF LIGHTS 33-46-00


DEACTIVATION/REACTIVATION 401 ALL
Deactivation of the Taxi Light 401 ALL
(8LR)
Refer to the CDL TASK: 33-2 401 ALL
Reactivation of the Taxi Light 404 ALL
(8LR)
Refer to the CDL TASK: 33-2 404 ALL
Deactivation of the Take Off Light 406 ALL
(7LR)
Refer to the CDL TASK: 33-9 406 ALL
Reactivation of the Take Off Light 409 ALL
(7LR)
Refer to the CDL TASK: 33-9 409 ALL

TAXI AND TAKE OFF LIGHTS 33-46-00


ADJUSTMENT/TEST 501 ALL
Operational Test of the Taxi and 501 ALL
Take Off Lights
Adjustment of the Light Mounts 503 001-012, 014-099
LIGHT - TAKE OFF 33-46-11
REMOVAL/INSTALLATION 401 ALL
Removal of the Take Off Light 401 ALL
(7LR)
Installation of the Take Off Light 405 ALL
(7LR)
Replacement of the Lamp in the 409 ALL
Take Off Light (7LR)
Replacement of the Halogen Bulb of 418 ALL
the Take Off Light (7LR)
Replacement of the Lens and the 423 ALL
Mirror of the Take Off Light (7LR)
LIGHT - TAKE OFF 33-46-11
ADJUSTMENT/TEST 501 001-012, 014-099
Adjustment of the Take Off Light 501 001-012, 014-099
(7LR)
Adjustment of the Take Off Light 505 001-012, 014-099
(7LR) - Alternative Procedure
LIGHT - TAXI 33-46-12
REMOVAL/INSTALLATION 401 ALL

33-CONTENTS Page 16
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT CH/SE/SU
________ C
_ ____ ___________
PAGE EFFECTIVITY
Removal of the Taxi Light (8LR) 401 ALL
Installation of the Taxi Light 407 ALL
(8LR)
Replacement of the Lamp in the 412 ALL
Taxi Light (8LR)
Replacement of the Halogen Bulb of 418 ALL
the Taxi Light (8LR)
Replacement of the Lens and the 423 ALL
Mirror of the Taxi Light (8LR)
LIGHT - TAXI 33-46-12
ADJUSTMENT/TEST 501 001-012, 014-099
Adjustment of the Taxi Light (8LR) 501 001-012, 014-099
Adjustment of the Taxi Light (8LR) 505 001-012, 014-099
- Alternative Procedure

LOGO LIGHTS 33-47-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Component Location 1 ALL
System Description 1 ALL
Power Supply 1 ALL
Operation 4 ALL

LOGO LIGHTS 33-47-00


DEACTIVATION/REACTIVATION 401 ALL
Deactivation of the logo light 401 ALL
lens (cover)
Refer to the CDL TASK: 33-5 401 ALL
Reactivation of the logo light 405 ALL
lens (cover)
Refer to the CDL TASK: 33-5 405 ALL
Deactivation of the logo light 408 ALL
lens (cover)
Refer to the CDL TASK: 33-5 408 ALL
Reactivation of the logo light 411 ALL
lens (cover)
Refer to the CDL TASK: 33-5 411 ALL

LOGO LIGHTS 33-47-00


ADJUSTMENT/TEST 501 ALL
Operational Test of the Logo 501 ALL
Lights
LIGHT - LOGO 33-47-11
MAINTENANCE PRACTICES 201 ALL

33-CONTENTS Page 17
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT CH/SE/SU
________ C
_ ____ ___________
PAGE EFFECTIVITY
Replacement of the Lamp of the 201 ALL
Logo Light 3LY (4LY)
LIGHT - LOGO 33-47-11
REMOVAL/INSTALLATION 401 ALL
Removal of the Logo Light 3LY 401 ALL
(4LY)
Installation of the Logo Light 3LY 405 ALL
(4LY)

ANTI-COLLISION/STROBE LIGHTING 33-48-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
The aircraft recognition 1 ALL
lighting system is designed as a
visual aid to other aircraft, so
reducing the possibility of a
collosion.
Component Location 1 ALL
System Description 6 ALL
Anti-Collision/Beacon Lights 6 001-012, 014-099
Strobe Lights 10 001-012, 014-099
Anti-Collision/Beacon Lights 10 101-199, 901-999
Strobe Lights 10 101-199, 901-999
Power Supply 10 ALL
Component Description 10 ALL
Anti-Collision/Beacon and Strobe 11 ALL
Light
Power Unit 11 ALL
Operation 12 ALL
Anti-Collision/Beacon Lights 12 001-012, 014-099
Anti-Collision/Beacon Lights 12 101-199, 901-999
Strobe Light 15 ALL

ANTI-COLLISION/STROBE LIGHTING 33-48-00


DEACTIVATION/REACTIVATION 401 ALL
Deactivation of the Anti-Collision 401 ALL
(Beacon) Lights 6LV and 7LV
Refer to the CDL TASK: 33-4 401 ALL
Reactivation of the Anti-Collision 409 ALL
(Beacon) Lights 6LV and 7LV
Refer to the CDL TASK: 33-4 409 ALL

ANTI-COLLISION/STROBE LIGHTING 33-48-00


ADJUSTMENT/TEST 501 ALL

33-CONTENTS Page 18
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT CH/SE/SU
________ C
_ ____ ___________
PAGE EFFECTIVITY
Operational Test of the 501 ALL
Anti-Collision/Strobe Lighting
Operational Test of the 504 ALL
Anti-Collision/Strobe Lighting
LIGHT - BEACON, UPPER 33-48-11
REMOVAL/INSTALLATION 401 ALL
Removal of the Upper Beacon/Strobe 401 ALL
Light 7LV from the Outside of the
Fuselage
Installation of the Upper 406 ALL
Beacon/Strobe Light 7LV from the
Outside of the Fuselage
Removal of the Upper Beacon/Strobe 413 ALL
Light 7LV from the Inside of the
Fuselage
Installation of the Upper 416 ALL
Beacon/Strobe Light 7LV from the
Inside of the Fuselage
Removal of the Flash Tube Assembly 423 ALL
of the Upper Beacon Light
Installation of the Flash Tube 426 ALL
Assembly of the Upper Beacon Light
LIGHT - BEACON, LOWER 33-48-12
REMOVAL/INSTALLATION 401 ALL
Removal of the Lower Beacon/Strobe 401 ALL
Light 6LV from the Fuselage
Outside
Installation of the Lower 406 ALL
Beacon/Strobe Light 6LV from the
Fuselage Outside
Test of the Lower Beacon/Strobe 411 ALL
Light 6LV
Removal of the Flash Tube Assembly 414 ALL
of the Lower Beacon Light
Installation of the Flash Tube 417 ALL
Assembly of the Lower Beacon Light
LIGHT - STROBE, TAIL CONE 33-48-13
REMOVAL/INSTALLATION 401 ALL
Removal of the Tail Cone 401 ALL
Strobe-Light (19LV)
Installation of the Tail Cone 406 ALL
Strobe-Light (19LV)
Replacement of the Strobe-Light 410 ALL
Flash-Tube Assembly
LIGHT - STROBE, WING TIP 33-48-14
REMOVAL/INSTALLATION 401 ALL

33-CONTENTS Page 19
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT CH/SE/SU
________ C
_ ____ ___________
PAGE EFFECTIVITY
Removal of the Strobe Light 401 ALL
Installation of the Strobe Light 405 ALL
Removal of the Strobe Light 411 ALL
Flash-Tube Assembly
Installation of the Strobe Light 415 ALL
Flash-Tube Assembly
POWER SUPPLY UNIT - UPPER BEACON LIGHT 33-48-36
REMOVAL/INSTALLATION 401 ALL
Removal of the Power Supply Unit 401 ALL
3LV
Installation of the Power Supply 404 ALL
Unit 3LV
POWER SUPPLY UNIT - LOWER BEACON LIGHT 33-48-37
REMOVAL/INSTALLATION 401 ALL
Removal of the Power Supply Unit 401 ALL
4LV
Installation of the Power Supply 404 ALL
Unit 4LV
POWER SUPPLY UNIT - WING TIP STROBE 33-48-38
LIGHT
REMOVAL/INSTALLATION 401 ALL
Removal of the Power Supply Unit 401 ALL
Installation of the Power Supply 405 ALL
Unit
POWER SUPPLY UNIT - TAIL CONE STROBE 33-48-39
LIGHT
REMOVAL/INSTALLATION 401 ALL
Removal of the Power Supply Unit 401 ALL
(18LV) of the Tail Cone
Strobe-Light
Installation of the Power Supply 404 ALL
Unit (18LV) of the Tail Cone
Strobe-Light

WING AND ENGINE SCAN LIGHTING 33-49-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Component Location 1 ALL
Description 1 ALL
Operation 1 ALL

WING AND ENGINE SCAN LIGHTING 33-49-00


DEACTIVATION/REACTIVATION 401 ALL
Deactivation of the Wing and 401 ALL
Engine Scan Light (3LX, 4LX)

33-CONTENTS Page 20
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

SUBJECT
_______ CH/SE/SU
________ C
_ ____ ___________
PAGE EFFECTIVITY
Refer to the CDL TASK: 33-1 401 ALL
Reactivation of the Wing and 404 ALL
Engine Scan Light (3LX, 4LX)
Refer to the CDL TASK: 33-1 404 ALL

WING AND ENGINE SCAN LIGHTING 33-49-00


ADJUSTMENT/TEST 501 ALL
Operational Test of the Wing and 501 ALL
Engine Scan Lights
LIGHT - WING AND ENGINE SCAN 33-49-11
REMOVAL/INSTALLATION 401 ALL
Removal of the Wing and Engine 401 ALL
Scan Light (3LX, 4LX)
Installation of the Wing and 405 ALL
Engine Scan Light (3LX, 4LX)
Replacement of the lamp of the 409 ALL
Wing and Engine Scan Light

__________________
EMERGENCY LIGHTING 33-50-00
DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
Component Location 1 ALL
Emergency Power Supply Units 1 001-012, 014-099
(EPSU)
Cabin Emergency Lights 1 001-012, 014-099
FPEEPMS 2 001-012, 014-099
Integrated Escape Slide Lights 2 001-012, 014-099
Emergency Power Supply Units 2 101-199, 901-999
(EPSU)
Cabin Emergency Lights 2 101-199, 901-999
Photoluminescent Marking System 2 101-199, 901-999
Integrated Escape Slide Lights 2 101-199, 901-999
System Description 3 ALL
General 3 ALL
Power Supply 3 ALL
BITE Test 3 ALL
General 4 001-012, 014-099
General 4 101-199, 901-999

CABIN EMERGENCY LIGHTING 33-51-00


DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
The cabin emergency-lighting 1 001-012, 014-099
system supplies power for: 901-999,
The cabin emergency-lighting 1 101-199,

33-CONTENTS Page 21
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

SUBJECT
_______ CH/SE/SU
________ C
_ PAGE ___________
____ EFFECTIVITY
system supplies power for:
Component Location 2 ALL
System Description 29 ALL
Emergency Lighting System 30 001-012, 014-099
Emergency Lighting System 30 101-199,
Emergency Lighting System 47 901-999,
Power Supply 47 ALL
Component Description 53 ALL
Emergency Power-Supply Unit 53 001-012, 014-099
Emergency Power-Supply Unit 55 101-199,
Emergency Power-Supply Units 57 901-999,
Exit Lights 59 001-012, 014-099
Cabin Emergency Light 59 001-012, 014-099
External Lights 59 001-012, 014-099
Floor Proximity Lights 59 001-012, 014-099
System Control 60 001-012, 014-099
Cabin Emergency Lights 60 101-199,
Exit Signs 60 101-199,
External Lights 60 101-199,
Floor Proximity Lights 61 101-199,
System Control 61 101-199,
Cabin Emergency Lights 61 901-901,
Exit Signs 61 901-901,
External Lights 62 901-901,
Floor Proximity Lights 62 901-901,
System Control 62 901-901,
Exit Lights 63 902-999,
Cabin Emergency Lights 63 902-999,
External Lights 63 902-999,
Floor Proximity Lights 63 902-999,
System Control 63 902-999,
Photoluminescent Floor 64 101-199, 901-999
Path-Marking-System
Operation 64 ALL
Operation of the Emergency 64 001-012, 014-099
Lighting System
Operation of the Emergency 66 101-199, 901-999
Lighting System
BITE TEST 70 ALL
Emergency Lighting System 70 001-012, 014-099
General 71 101-199, 901-999
Emergency Lighting Batteries 74 001-012, 014-099
Description 74 101-199, 901-999
Operation 81 101-199, 901-999

33-CONTENTS Page 22
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT ________
CH/SE/SU C
_ PAGE ___________
____ EFFECTIVITY
CABIN EMERGENCY LIGHTING 33-51-00
DEACTIVATION/REACTIVATION 401 ALL
Deactivation of the EMER SYSTEM 401 001-012, 014-099
TEST of the Cabin Emergency
Lighting System
Refer to the MMEL TASK: 401 001-012, 014-099
33-50-07-B)
Deactivation of the EMER EXIT LT 404 ALL
OFF Annunciator Light 5WL
Refer to the MMEL TASK: 33-50-08 404 ALL
Reactivation of the EMER EXIT LT 410 ALL
OFF Annunciator Light 5WL
Refer to the MMEL TASK: 33-50-08 410 ALL

CABIN EMERGENCY LIGHTING 33-51-00


ADJUSTMENT/TEST 501 ALL
Operational Test of Emergency 501 ALL
Lights
Check Battery Capacity 506 ALL
Remove Batteries for Capacity 513 ALL
Check
Check manual Operation from both 514 ALL
Control Panels and check all Cabin
Lights and Signs illuminated by
Batteries
Operational Test of Emergency 519 ALL
Lights not with CIDS
Operational Test of the Emergency 528 ALL
Lighting in the Cabin by LIGHT
EMER Pushbutton Switch
Operational Test of the Emergency 532 ALL
Lighting in the Cabin by EMER
EXIT LT Switch
Check Door Switch Power supplied 535 ALL
by Emer. Light System and check
Door Switch Operation to activate
the Exterior Lights
Check all Cabin Lights and Signs 558 ALL
for correct illumination
LIGHT - EMERGENCY, CABIN 33-51-11
REMOVAL/INSTALLATION 401 ALL
Removal of the Cabin Emergency 401 ALL
Lights
Installation of the Cabin 419 ALL
Emergency Light

33-CONTENTS Page 23
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT ________
CH/SE/SU C
_ PAGE ___________
____ EFFECTIVITY
SIGN - EXIT MARKING, WALL MOUNTED 33-51-13
REMOVAL/INSTALLATION 401 ALL
Removal of the Cabin Wall-Mounted 401 ALL
Emergency-Exit-Markers
Installation of the Cabin 409 ALL
Wall-Mounted
Emergency-Exit-Markers
LIGHT - AUXILIARY, LAVATORY 33-51-14
REMOVAL/INSTALLATION 401 ALL
Removal of the Auxiliary Lavatory 401 001-012, 014-099
Light 80WL
Installation of the Auxiliary 406 001-012, 014-099
Lavatory Light 80WL
Removal of the Auxiliary Lavatory 410 001-012, 014-099
Light 81WL
Installation of the Auxiliary 415 001-012, 014-099
Lavatory Light 81WL
Removal of the Auxiliary Lavatory 420 001-012, 014-099
Light 83WL
Installation of the Auxiliary 425 001-012, 014-099
Lavatory Light 83WL
Removal of the Auxiliary/Mirror 429 101-199, 901-999
Lavatory Light
Installation of the 434 101-199, 901-999
Auxiliary/Mirror Lavatory Light
LIGHT - EMERGENCY, OVERWING 33-51-15
REMOVAL/INSTALLATION 401 001-012, 014-099
901-999,
Removal of the Emergency Overwing 401 001-012, 014-099
Lights 60WL (61WL, 62WL, 63WL) 901-999,
Installation of the Emergency 406 001-012, 014-099
Overwing Lights 60WL (61WL, 62WL, 901-999,
63WL)
SIGN - EMERGENCY EXIT 33-51-16
REMOVAL/INSTALLATION 401 ALL
Removal of the Emergency Exit Sign 401 ALL
Installation of the Emergency Exit 408 ALL
Sign
SIGN - EMERGENCY EXIT LOCATION 33-51-17
REMOVAL/INSTALLATION 401 ALL
Removal of the Emergency Exit 401 ALL
Location-Sign
Installation of the Emergency Exit 408 ALL
Location-Sign
LIGHT - EMERGENCY EXIT LOCATION, 33-51-18
SEAT/WALL MOUNTED

33-CONTENTS Page 24
Feb 01/08
R
IAC
CHAPTER 33
__________

LIGHTS

TABLE OF CONTENTS
_________________

_______
SUBJECT CH/SE/SU
________ C
_ ____ ___________
PAGE EFFECTIVITY
REMOVAL/INSTALLATION 401 001-012, 014-099
Removal of the Seat/Wall-Mounted 401 001-012, 014-099
Emergency-Exit Location-Light
Installation of the 404 001-012, 014-099
Seat/Wall-Mounted Emergency-Exit
Location-Light
LIGHT - EMERGENCY, SEAT/WALL MOUNTED 33-51-19
REMOVAL/INSTALLATION 401 001-012, 014-099
Removal of the Seat/Wall-Mounted 401 001-012, 014-099
Emergency Light
Installation of the 404 001-012, 014-099
Seat/Wall-Mounted Emergency Light
PHOTOLUMINESCENT STRIP - FLOOR 33-51-21
PROXIMITY EMERGENCY ESCAPE PATH
MARKING
REMOVAL/INSTALLATION 401 101-199, 901-999
Removal of the Photoluminescent 401 101-199, 901-999
Strip of the Floor-Proximity
Emergency-Escape Path-Marking
Installation of the 410 101-199, 901-999
Photoluminescent Strip of the
Floor-Proximity Emergency-Escape
Path-Marking
Discard Photoluminescent Floor 414 101-199, 901-999
Path Marking System
PHOTOLUMINESCENT STRIP - FLOOR 33-51-21
PROXIMITY EMERGENCY ESCAPE PATH
MARKING
CLEANING/PAINTING 701 101-199, 901-999
Cleaning of the Photoluminescent 701 101-199, 901-999
Strips of the Floor-Proximity
Emergency-Escape Path-Marking
POWER SUPPLY UNIT - EMERGENCY 33-51-38
REMOVAL/INSTALLATION 401 ALL
Removal of the Emergency 401 ALL
Power-Supply Unit (EPSU)
Installation of the Emergency 411 ALL
Power-Supply Unit (EPSU)
Removal of the Battery of the 422 ALL
Emergency Power-Supply Unit
Installation of the Battery of the 428 ALL
Emergency Power-Supply Unit

33-CONTENTS Page 25
Feb 01/08
R
IAC
LIGHTS - GENERAL - DESCRIPTION AND OPERATION
____________________________________________

1. _______
General
The aircraft lighting system provides illumination inside and outside of the
aircraft. The system comprises:

A. Cockpit Lights
The cockpit lighting consists of the following sub-systems:
- general illumination of cockpit panels, instruments and work surfaces,
- integral lighting of panels and instruments,
- test system for annunciator lights,
- dimming system for annunciator lights.

B. Cabin Lights
The cabin lighting consists of the following sub-systems:
- general illumination of cabin, galley areas and entrances,
- illumination of the lavatories,
- passenger reading lights (customer option),
- cabin lighted signs,
- work lights for the cabin attendants.

C. Cargo and Service Compartment Lights


The cargo and service compartment lighting provides illumination and
power outlets for maintenance purposes. The system comprises:
- service area lighting for equipment and APU compartments,
- air conditioning duct and accessory compartment lights,
- FWD and AFT cargo compartment lights,
- equipment compartment lights,
- wheel well lighting.

R D. External Lights
R The external lights illuminate the runways and/or taxiway, some aircraft
R surfaces and give an indication of the aircrafts position.
R The system has:
R - three navigation lights, colored red, green and white, one is installed
R at the tip of each wing and one at the aft of the fuselage,
R - landing lights, which have two high-power lights that retract and are
R installed one under each wing,
R - runway turnoff lights, which have two lights and are installed on the
R nose landing gear,
R - one takeoff light and one taxi light are installed on the nose landing
R gear,
R - two anticollision beacon lights, which flash red, are installed one at
R the top and one at the bottom of the fuselage,
R - three strobe lights, which flash white, are installed one on each wing
R tip leading-edge and one on the tailcone below the exhaust of the
R Auxiliary Power Unit (APU),



EFF :

ALL  33-00-00

Page 1
May 01/07
 
IAC 
R - wing and engine scan lights are installed one at each side of the
R fuselage to illuminate the wing surface areas and engine intakes.

E. Cabin Emergency Lighting


The emergency lighting system provides illumination of the cabin and exit
signs in the event of a failure of the main lighting system.
Batteries supply electrical power for these lights independently of the
aircraft power supplies.



EFF :

ALL  33-00-00

Page 2
May 01/07
 
IAC 
COCKPIT - DESCRIPTION AND OPERATION
___________________________________

1. _______
General
The cockpit lighting system allows the flight crew to see:
- all the equipment details in the cockpit,
- all the inscriptions and necessary indications whatever the level of
light.
The various lighting sources are:
- cockpit lighting: dome lights,
- panels and instruments lighting: flood lights or lamps,
- map table lighting: reading lights,
- console lighting: lamps,
- integral lighting of VU panels and instruments,
- lighting of annunciators and pushbutton switches.

There are two electrical outlets in the cockpit:


- 28VDC one,
- and 115VAC 400 Hz one.

A spare lamps box is provided in the cockpit. It is located on the left side
panel.
(Ref. Fig. 001)
For contents of the spare lamps box refer to IPC 33-12-01.

2. Power
____________
Supply
This figure shows the general power supply of busbars used for cockpit
lighting

**ON A/C 001-012, 014-099,

(Ref. Fig. 002)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 002A)



EFF :

ALL  33-10-00

Page 1
Feb 01/07
 
IAC 
Spare Lamp Box-Component location
Figure 001



EFF :

ALL  33-10-00

Page 2
Feb 01/96
 
IAC 
Electrical Power-General Schematic
Figure 002


R

EFF :

001-012, 014-099,  33-10-00

Page 3/4
May 01/06
 
IAC 
Electrical Power-General Schematic
Figure 002A


R

EFF :

101-199, 901-999,  33-10-00

Page 5/6
Feb 01/07
 
IAC 
GENERAL ILLUMINATION - DESCRIPTION AND OPERATION
________________________________________________

1. _______
General
The cockpit lighting system has 5 functions:
- dome lights,
- side consoles,
- instrument panels,
- reading lights,
- service outlets.

2. Component
__________________
Location
(Ref. Fig. 001)

**ON A/C 001-012, 014-027,

(Ref. Fig. 002)

**ON A/C 028-099,

(Ref. Fig. 002A)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 002B)

**ON A/C 001-012, 014-027,

-------------------------------------------------------------------------------
FIN I FUNCTIONAL DESIGNATION I PANELIZONEIACCESS I ATA
I I I I DOOR I REF.
-------------------------------------------------------------------------------
14LE SW-INT LT/DOME 25VU 210
15LE SW-CONSOLE/FLOOR 301VU 211
16LE SW-CONSOLE/FLOOR 500VU 212
17LE LT-CONSOLE, CAPT 211 33-12-15
18LE LT-CONSOLE, F/O 212 33-12-15
19LE LT-CONSOLE, CAPT 211 33-12-15
20LE LT-CONSOLE, F/O 212 33-12-15
21LE LT-CONSOLE, CAPT 211 33-12-15
22LE LT-CONSOLE, F/O 212 33-12-15
23LE LT-BRIEFCASE 1VU 211 33-12-15
24LE LT-BRIEFCASE 7VU 212 33-12-15
25LE LT-READING, CAPT 211 33-12-12



EFF :

ALL  33-12-00

Page 1
Feb 01/07
 
IAC 
R General Illumination - Component Location
R Figure 001



EFF :

ALL  33-12-00

Page 2
Aug 01/96
 
IAC 
R General Illumination - Component Location
R Figure 002


R

EFF :

001-012, 014-027,  33-12-00

Page 3
Aug 01/96
 
IAC 
R General Illumination - Component Location
R Figure 002A


R

EFF :

028-099,  33-12-00

Page 4
Aug 01/96
 
IAC 
General Illumination - Component Location
Figure 002B


R

EFF :

101-199, 901-999,  33-12-00

Page 5
Feb 01/07
 
IAC 
-------------------------------------------------------------------------------
FIN I FUNCTIONAL DESIGNATION I PANELIZONEIACCESS I ATA
I I I I DOOR I REF.
-------------------------------------------------------------------------------
26LE LT-READING, F/O 212 33-12-12
27LE LT-CENTER PEDESTAL 48VU 210 33-12-14
28LE RHEOSTAT-FLOOD LT/PED 112VU 212
29LE LT-READING-SUPPLEMENTARY 54VU 212 33-12-12
30LE RHEOSTAT-READING LT 54VU 212

R **ON A/C 028-099, 101-199, 901-999,

14LE SW-INT LT/DOME 25VU 210


15LE SW-CONSOLE/FLOOR 301VU 211
16LE SW-CONSOLE/FLOOR 500VU 212
17LE LT-CONSOLE, CAPT 211 33-12-15
18LE LT-CONSOLE, F/O 212 33-12-15
19LE LT-CONSOLE, CAPT 211 33-12-15
20LE LT-CONSOLE, F/O 212 33-12-15
21LE LT-CONSOLE, CAPT 211 33-12-15
22LE LT-CONSOLE, F/O 212 33-12-15
23LE LT-BRIEFCASE 1VU 211 33-12-15
24LE LT-BRIEFCASE 7VU 212 33-12-15
27LE LT-CENTER PEDESTAL 48VU 210 33-12-14
28LE RHEOSTAT-FLOOD LT/PED 112VU 212
29LE LT-READING SUPPLEMENTARY 54VU 212 33-12-12
30LE RHEOSTAT-READING LT 54VU 212

**ON A/C 001-012, 014-099,

29LE LT-READING SUPPLEMENTARY 54VU 211 33-12-12


30LE RHEOSTAT-READING LT 54VU 211

**ON A/C ALL

31LE OUTLET-COCKPIT (115VAC2) 122VU 212


32LE OUTLET-COCKPIT (28VDC2) 122VU 212
35LE RHEOSTAT-FLOOD LT/MAIN PNL 111VU 211
36LE LT-MAIN INSTRUMENT PNL, F/O 130VU 212 33-12-13
37LE LT-MAIN INSTRUMENT PNL, CAPT 131VU 211 33-12-13



EFF :

ALL  33-12-00

Page 6
Feb 01/07
 
IAC 
**ON A/C 001-012, 014-027,

-------------------------------------------------------------------------------
FIN I FUNCTIONAL DESIGNATION I PANELIZONEIACCESS I ATA
I I I I DOOR I REF.
-------------------------------------------------------------------------------

38LE LT-MAIN INSTRUMENT PNL, CENTER 13VU 210 33-12-13


161LE LT-DOME, CAPT 453VU 211 33-12-11
162LE LT-DOME, F/O 452VU 212 33-12-11
163LE LT-DOME, CAPT 453VU 211 33-12-11
164LE LT-DOME, F/O 452VU 212 33-12-11
165LE LT-DOME, CAPT 453VU 211 33-12-11
166LE LT-DOME, F/O 452VU 212 33-12-11
167LE LT-DOME, CAPT 453VU 211 33-12-11
168LE LT-DOME, F/O 452VU 212 33-12-11

R **ON A/C 028-099, 101-199, 901-999,

38LE LT-MAIN INSTRUMENT PNL, CENTER 13VU 210 33-12-13


39LE RHEOSTAT-MAP TABLE LT, CAPT 211 33-12-18
40LE RHEOSTAT-MAP TABLE LT, F/O 212 33-12-18
41LE LT-MAP TABLE, CAPT 211 33-12-12
42LE LT-MAP TABLE, F/O 212 33-12-12
161LE LT-DOME, CAPT 453VU 211 33-12-11
162LE LT-DOME, F/O 452VU 212 33-12-11
163LE LT-DOME, CAPT 453VU 211 33-12-11
164LE LT-DOME, F/O 452VU 212 33-12-11
165LE LT-DOME, CAPT 453VU 211 33-12-11
166LE LT-DOME, F/O 452VU 212 33-12-11
167LE LT-DOME, CAPT 453VU 211 33-12-11
168LE LT-DOME, F/O 452VU 212 33-12-11

**ON A/C ALL

3. __________________
System Description

A. Cockpit Lighting by Dome Lights


(Ref. Fig. 003)
The INT LT/DOME switch 14LE with 3 positions (OFF, DIM, BRIGHT) located
on the overhead control and indicating panel 25VU controls the two dome
lights.
Each dome light has four halogen long lasting lamps.



EFF :

ALL  33-12-00

Page 7
Feb 01/07
 
IAC 
General Illumination - Dome Light
Figure 003



EFF :

ALL  33-12-00

Page 8
May 01/06
R  
IAC 
(1) Normal operation
When the INT LT/DOME switch 14LE is in the BRT position:
- the dome light in 453VU is supplied with 28VDC from busbar 601PP
through circuit breaker 3LE on the rear C/B panel 122VU.
- the dome light in 452VU is supplied with 28VDC from essential
busbar 401PP through circuit breaker 1LE on the overhead C/B panel
49VU.
When the switch is in the DIM position the light intensity decreases.
In the BRT position, the lights are supplied in parallel and in the
DIM position they are supplied in series by groups of two.

(2) Emergency lighting


If the busbar 601PP is lost, only the dome light in 452VU on the
cockpit right side remains on. It is supplied by essential busbar
401PP through circuit breaker 1LE.
In this configuration, the 3 positions: OFF, DIM and BRT of the
switch 14LE are operational.

B. Console Lighting
(Ref. Fig. 004)
Four lights are used for the lighting of each console (3 for the console
itself and 1 for the briefcase).
The associated floor lighting consists of four lights fitted at the base
of the Captain and First Officer seats.

(1) Captain console and floor lighting


The CONSOLE/FLOOR switch 15LE with 3 positions: OFF - DIM - BRT
controls the 28VDC supply to these lighting systems.
The switch is located on the Captain lighting/loud speaker control
panel 301VU.
The normal busbar 103PP supplies the 8 lights through the circuit
breaker 5LE located on the rear circuit breaker panel 122VU.

(2) First Officer console and floor lighting


The CONSOLE/FLOOR switch 16LE with 3 positions:
OFF - DIM - BRT controls the 28VDC supply to these lighting systems.
The switch is located on the F/O lighting/loud speaker control panel
500VU.
The normal busbar 204PP supplies the 8 lights through the circuit
breaker 4LE located on the rear circuit breaker panel 122VU.

C. Instrument Panel Lighting

**ON A/C 001-012, 014-027,

(Ref. Fig. 005)



EFF :

ALL  33-12-00

Page 9
May 01/06
R  
IAC 
General Illumination - Side Console Lighting and Cockpit Outlets
Figure 004


R

EFF :

ALL  33-12-00

Page 10
May 01/06
 
IAC 
General Illumination - Instrument Panel Lighting and Reading Lights
Figure 005


R

EFF :

001-012, 014-027,  33-12-00

Page 11
May 01/06
 
IAC 
**ON A/C 028-099,

(Ref. Fig. 005A)

**ON A/C 101-199, 901-999,

(Ref. Fig. 005B)

R **ON A/C 001-012, 014-027,

R Post SB 33-1057 For A/C 001-012,014-027,

(Ref. Fig. 005C)

R **ON A/C 028-099,

R Post SB 33-1057 For A/C 028-099,

R (Ref. Fig. 005D)

R **ON A/C 901-901,

R Post SB 33-1057 For A/C 901-901,

R (Ref. Fig. 005E)

**ON A/C 001-012, 014-027,

Three lights 36LE (First Officer), 37LE (Captain) and 38LE (center)
provide the ambient lighting of the Captain, First Officer and center
main instrument panels.
They are installed under the glareshield and illuminate only the
instruments and the placards located on four zones of the main instrument
panels:
- 2 zones at the ends of the main instrument panels, 301VU and 500VU,
- 2 zones on the center instrument panel:
One on the left side which has the emergency equipments, one on the
right side which has items of equipment such as the landing gear
control lever, clock, the landing gear control and indicating panel
402VU etc.

The single control dual rheostat 35LE located on the center pedestal on
the FLOOD LT/INTEG LT panel 111VU controls these lights:
- The first rheostat controls:



EFF :

ALL  33-12-00

Page 12
May 01/08
 
IAC 
General Illumination - Instrument Panel Lighting and Reading Lights
Figure 005A


R

EFF :

028-099,  33-12-00

Page 13
May 01/06
 
IAC 
General Illumination - Instrument Panel Lighting and Reading Lights
Figure 005B


R

EFF :

101-199, 901-999,  33-12-00

Page 14
Feb 01/07
 
IAC 
R General Illumination - Instrument Panel Lighting and Reading Lights
R Figure 005C


R

EFF :

001-012, 014-027,  33-12-00

Page 15
May 01/08
 
IAC 
General Illumination - Instrument Panel Lighting and Reading Lights
R Figure 005D


R

EFF :

028-099,  33-12-00

Page 16
May 01/08
 
IAC 
R General Illumination - Instrument Panel Lighting and Reading Lights
R Figure 005E


R

EFF :

901-901,  33-12-00

Page 17
May 01/08
 
IAC 
The brightness of the 11.5W halogen lamps of the First Officer light
36LE:
- the section of the center instrument panel light 38LE which illuminates
the right zone. The normal busbar 103PP supplies the lamps with 28VDC
through circuit breaker 2LE located on rear circuit breaker panel
122VU.
- The second rheostat controls:
The brightness of the 11.5W halogen lamps of the Captain light 37LE and
the section of the center instrument panel light 38LE which illuminates
the left zone (standby equipment).

**ON A/C 028-099, 101-199, 901-999,

Three lights 36LE (First Officer), 37LE (Captain) and 38LE (center)
provide the ambient lighting of the Captain, First Officer and center
main instrument panels.
They are installed under the glareshield and illuminate only the
instruments and the placards located on four zones of the main instrument
panels:
- 2 zones at the ends of the main instrument panels, 301VU and 500VU,
- 2 zones on the center instrument panel:
One on the left side which has the emergency items of equipment, one on
the right side which has equipments such as the landing gear control
lever, clock, the landing gear control and indicating panel 402VU etc.

The single control dual rheostat 35LE located on the center pedestal on
the FLOOD LT/INTEG LT panel 111VU controls these lights:
- The first rheostat controls:
The brightness of the halogen lamps of the F/O main instrument-panel
light 36LE:
- the section of the center instrument panel light 38LE which illuminates
the right zone. The normal busbar 103PP supplies the lamps with 28VDC
through circuit breaker 2LE located on rear circuit breaker panel
122VU.
- The second rheostat controls:
The brightness of the halogen lamps of the Captain main instrument
panel light 37LE and the section of the center instrument panel light
38LE which illuminates the left zone (standby equipment).
The rheostat of the F/O main instrument-panel light controls the
intensity of the six halogen lamps of the F/O main instrument-panel.
The rheostat of the Captain main instrument-panel light controls the
intensity of the six halogen lamps of the Captain main instrument-panel.



EFF :

ALL  33-12-00

Page 18
May 01/08
R  
IAC 
**ON A/C ALL

D. Reading Lights

**ON A/C 001-012, 014-027,

(Ref. Fig. 005)

**ON A/C 028-099,

(Ref. Fig. 005A)

**ON A/C 101-199, 901-999,

(Ref. Fig. 005B)

R **ON A/C 001-012, 014-027,

R Post SB 33-1057 For A/C 001-012,014-027,

(Ref. Fig. 005C)

R **ON A/C 028-099,

R Post SB 33-1057 For A/C 028-099,

R (Ref. Fig. 005D)

R **ON A/C 901-901,

R Post SB 33-1057 For A/C 901-901,

R (Ref. Fig. 005E)

**ON A/C 001-012, 014-027,

(1) Captain and First Officer reading lights (25LE and 26LE)
The two reading lights are fitted on the upright of the side windows
of the cockpit. They swivel and illuminate the sliding tables of the
Captain and First Officer, the consoles and the ceiling if necessary.
Each reading light has:
- a 11.5W, 28V halogen bulb of the long lasting type (2000 hours),



EFF :

ALL  33-12-00

Page 19
May 01/08
 
IAC 
- a rheostat which provides the three functions OFF - DIM - BRIGHT,
- a variable diameter diaphragm to reduce or increase the lighted
surface (the diameter varies from 100 mm to 350 mm).

**ON A/C 028-099, 101-199, 901-999,

(1) Captain and First Officer map table lights (41LE and 42LE)
The two map table lights are fitted on the upright of the side
windows of the cockpit. They swivel and illuminate the sliding tables
of the Captain and First Officer and the map tables located on the
sliding windows.
Each map table light has a 4.8W, 28V incandescent light.
The rheostats (39LE and 40LE) control these lights.
Each map table light has a rheostat which controls the light.

**ON A/C ALL

(2) Supplementary reading light (First Officer)


The supplementary reading light 29LE is equipped with a long lasting
halogen lamp and swivels. The READING LT rheostat 30LE is used to
control the reading light brightness.

(3) Center pedestal light


The center pedestal light 27LE is equipped with a 11.5W long-lasting
lamp. It swivels towards the rear of the pedestal.
The FLOOD LT/PED rheostat 28LE is used to control the light
brightness.

**ON A/C 001-012, 014-099,

(4) Second supplementary reading light (Captain)


The installation of the second supplementary reading light 29LE in
54VU, its power supply (103PP) and control (rheostat 30LE) are
identical to those of the first supplementary reading light.



EFF :

ALL  33-12-00

Page 20
May 01/08
 
IAC 
**ON A/C ALL

E. Cockpit Outlets
(Ref. Fig. 004)

(1) 28VDC outlet


The 28VDC outlet (32LE) located on the rear circuit breaker panel
122VU delivers 280 Watts.
The DC busbar 601PP supplies this outlet through circuit breaker 11LS
located on the rear circuit breaker panel 122VU.

(2) 115VAC 400Hz outlet


The 115VAC - 400Hz outlet (31LE) located on the rear circuit breaker
panel 122VU delivers 1150 Watts. The AC busbar 216XP-C supplies this
outlet through the circuit breaker 12LS located on the rear circuit
breaker panel 122VU.



EFF :

ALL  33-12-00

Page 21
May 01/08
 
IAC 
GENERAL ILLUMINATION - ADJUSTMENT/TEST
______________________________________

TASK 33-12-00-710-001

Operational Test of the General Illumination

1. __________________
Reason for the Job

Make sure that the general illumination of the cockpit operates correctly.

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-12-00-861-051

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-12-00-865-050

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
49VU LIGHTING/EMER LT/CKPT/DOME 1LE H08
122VU LIGHTING/CKPT/DOME 3LE Y06
122VU LIGHTING/FLOOD/F/O/SIDE 4LE Z06
122VU LIGHTING/FLOOD/CAPT/SIDE 5LE Z05
122VU LIGHTING/FLOOD/CTR INST/PNL 2LE Z04



EFF :

ALL  33-12-00

Page 501
Aug 01/06
 
IAC 
R

4. Procedure
_________

Subtask 33-12-00-710-050

A. Test of the Dome Lights

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the panel 25VU: On the dome light


- put the DOME switch in the DIM panels 452VU and 453VU:
position, - the four lights come on with a dim
intensity.

- put the DOME switch in the BRT - the four lights get brighter,
position,

- put the DOME switch in the OFF - the lights go off.


position.

Subtask 33-12-00-710-053

B. Test of the Console and Briefcase Lights

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the panel 301VU: On the Captain side:


- put the CONSOLE/FLOOR switch in - the three console lights come on,
the DIM position, - on the panel 1VU, the briefcase light
comes on,
- the four floor lights come on,

- put the switch in the BRT - these lights get brighter,


position,

- put the switch in the OFF - the lights go off.


position.

2. On the panel 500VU: On the First Officer side:


- put the CONSOLE/FLOOR switch in - the three console lights come on,
the DIM position, - on the panel 7VU, the briefcase light
comes on,
- the four floor lights come on,
with a dim intensity,



EFF :

ALL  33-12-00

Page 502
Aug 01/06
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- put the switch in the BRT - the lights get brighter,
position,

- put the switch in the OFF - the lights go off.


position .

R **ON A/C 001-012, 014-027,

R Subtask 33-12-00-710-051-C

R C. Test of the Instrument Lighting, of the Reading Lights, of the


R Supplementary Reading Lights and of the Center Pedestal Light

R -------------------------------------------------------------------------------
R ACTION RESULT
R -------------------------------------------------------------------------------

R 1. On the panel 111VU: On the Captain, First Officer and


R - turn the FLOOD LT/MAIN PNL center instrument panels:
R rheostat from the OFF to the - the lights get brighter until they
R BRT position are fully bright

R - turn the rheostat from the BRT - the lights get dimmer and then go
R to the OFF position. off.

R 2. On the Captain and the First On the Captain and the First officer
R Officer sides: sides:
R - pull the reading lights - the reading lights come on with a dim
R intensity
R - turn the READING LT rheostats - the reading lights get brighter until
R clockwise they are fully bright

R - turn the rheostats - the reading lights get dimmer


R counterclockwise

R - push the reading lights into - the reading lights go off.


R their holders

R 3. On panel 54VU: On panel 54VU:


R - turn the READING LT rheostat - the reading light gets brighter until
R from the OFF to the BRT it is fully bright
R position



EFF :

ALL  33-12-00

Page 503
Feb 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
R - turn the rheostat from the BRT - the reading light gets dimmer and
R to the OFF position. then goes off.

R 4. On the panel 112VU: On the panel 48VU:


R - turn the FLOOD LT/PED rheostat - the center pedestal light gets
R from the OFF to the BRT brighter until it is fully bright
R position

R - turn the rheostat from the BRT - the center pedestal light gets dimmer
R to the OFF position and then goes off.

**ON A/C 028-099,

Subtask 33-12-00-710-051-A

C. Test of the Instrument Lighting, of the Supplementary Reading Lights, of


the Map Table Lights and of the Center Pedestal Light

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the panel 111VU: On the center instrument panel:


- turn the FLOOD LT/MAIN PNL - the lights get brighter until they
rheostat from the OFF to the are fully bright.
BRT position,

On the Captain and First-Officer


instrument-panels:
- the lights get brighter until they
are fully bright,

- turn the rheostat from the BRT - the flood lights get dimmer and then
to the OFF position. go off.

R 2. On panel 54VU: On panel 54VU:


- turn the READING LT rheostat - the reading light gets brighter until
from the OFF to the BRT it is fully bright,
position,

- turn the rheostat in the - the reading light gets dimmer and
opposite direction. then goes off.


R

EFF :

001-012, 014-099,  33-12-00

Page 504
Feb 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
3. On the panel 131VU: On the Captain main instrument-panel:
- turn the rheostat of the - the flood lights get brighter until
Captain main they are fully bright,
instrument panel light from the
OFF to the BRT position,

- turn the rheostast from the BRT - the flood lights get dimmer and then
to the OFF position. go off.

4. On the panel 130VU: On the F/O main instrument-panel:


- turn the rheostat of the F/O - the flood lights get brighter until
main they are fully bright,
instrument-panel light from the
OFF to the BRT position,

- turn the rheostat from the BRT - the flood lights get dimmer and then
to the OFF position. go off.

5. On the Captain and the On the Captain and First Officer sides:
First-Officer sides:
- turn the rheostats of the map
table lights,

- set the switches to ON, - the map table lights come on


with a dim intensity,

- turn the rheostast, - the map table lights get brighter


until they are fully bright,

- turn the rheostats in the - the map table lights get dimmer,
opposite direction,

- set the switch to OFF. - the map table light goes off.

6. On the panel 112VU: On the panel 48VU:


- turn the FLOOD LT/PED rheostat - the center pedestal light gets
from the OFF to the BRT brighter until it is fully bright,
position,

- turn the rheostat in the - the center pedestal light gets dimmer
opposite direction. and then goes off.



EFF :

028-099,  33-12-00

Page 505
Feb 01/07
R  
IAC 
R **ON A/C 101-199, 901-999,

Subtask 33-12-00-710-051-B

C. Test of the Instrument Lighting, of the Supplementary Reading Light, of


the Map Table Lights and of the Center Pedestal Light

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the panel 111VU: On the center instrument panel:


- turn the FLOOD LT/MAIN PNL - the lights get brighter until they
rheostat from the OFF to the are fully bright,
BRT position,

On the Captain and First Officer main


instrument panels:
- the lights get brighter until they
are fully bright,

- turn the rheostat from the BRT - the lights get dimmer and then go
to the OFF position. off.

2. On the First Officer side: On the First Officer side:


- pull the supplementary reading - the supplementary reading light comes
light, on with a dim intensity,

- turn the READING LT rheostat, - the supplementary reading light gets


brighter until it is fully bright,

- turn the rheostat in the - the supplementary reading light gets


opposite direction, dimmer,

- push the supplementary reading - the supplementary reading light goes


light into its holder. off.

3. On the panel 131VU: On the Captain main instrument-panel:


- turn the rheostat of the - the lights get brighter until they
captain main instrument-panel are fully bright,
light from the OFF to the OFF
to the BRT position,

- turn the rheostat from the BRT - the lights get dimmer and then go
to the OFF position. off.


R

EFF :

101-199, 901-999,  33-12-00

Page 506
Feb 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
4. On the panel 130VU: On the F/O main instrument-panel:
- turn the rheostat of the F/O - the lights get brighter until they
main instrument-panel light are fully bright,
from the OFF to the BRT
position,

- turn the rheostat from the BRT - the lights get dimmer and then go
to the OFF position. off.

5. On the Captain and the On the Captain and First Officer sides:
First-Officer sides:
- turn the rheostats of the map
table lights,

- set the switches to ON, - the map table lights come on with a
dim intensity,

- turn the rheostasts, - the map table lights get brighter


until they are fully bright,

- turn the rheostats in the - the map table lights get dimmer,
opposite direction,

- set the switch to OFF. - the map table light goes off.

6. On the panel 112VU: On the panel 48VU:


- turn the FLOOD LT/PED rheostat - the center pedestal light gets
from the OFF to the BRT brighter until it is fully bright,
position,

- turn the rheostat in the - the center pedestal light gets dimmer
opposite direction, and then goes off.

**ON A/C ALL

5. Close-up
________

Subtask 33-12-00-862-051

A. De-energize the aircraft electrical circuits


(Ref. TASK 24-41-00-862-002).


R

EFF :

ALL  33-12-00

Page 507
Feb 01/07
 
IAC 
_______________________________________________________________________
LIGHT - DOME, COCKPIT (161LE,162LE,163LE,164LE,165LE,166LE,167LE,168LE)
____________________
REMOVAL/INSTALLATION

TASK 33-12-11-000-002

Removal of the Cockpit Dome Light (161LE, 162LE, 163LE, 164LE, 165LE, 166LE,
167LE, 168LE)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific ALLEN wrench

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-12-11-991-001 Fig. 401



EFF :

ALL  33-12-11

Page 401
Feb 01/96
 
IAC 
3. __________
Job Set-up

Subtask 33-12-11-865-054

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
49VU LIGHTING/EMER LT/CKPT/DOME 1LE H08
122VU LIGHTING/CKPT/DOME 3LE Y06

Subtask 33-12-11-010-050

B. Remove the ceiling panel (211CC for the Captain Dome Lights and 212CC for
the F/O Dome Lights) with an ALLEN wrench.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-12-11-991-001)

Subtask 33-12-11-020-053

A. Removal of the bulb

(1) Remove the defective bulb (10).

Subtask 33-12-11-020-054

B. Remove of the dome light box

(1) Disconnect the electrical connector (1) from the socket (2).

(2) Remove the four screws (4) and washers (3) that attach the dome light
box.

(3) Put a blanking caps on the disconnected electrical connector (1) and
the socket (2).

(4) Remove the dome light box.



EFF :

ALL  33-12-11

Page 402
Aug 01/06
 
IAC 
Dome Light
Figure 401/TASK 33-12-11-991-001



EFF :

ALL  33-12-11

Page 403
Feb 01/96
 
IAC 
Subtask 33-12-11-020-055

C. Removal of the socket

(1) Remove the bulb (10).

(2) Remove the two screws (14) and the two screws (5) with their nuts
(15) that attach the plate (6) to the defective socket (9). Hold the
plate during the removal.

(3) Remove the plate (6).

(4) Remove the screw (12), the washer (13) and the power supply cable
(11).

(5) Remove the nut (7) and the washer (8).

(6) Remove the defective socket (9).



EFF :

ALL  33-12-11

Page 404
Feb 01/96
 
IAC 
TASK 33-12-11-400-002

Installation of the Cockpit Dome Light (161LE, 162LE, 163LE, 164LE, 165LE,
166LE, 167LE, 168LE)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific ALLEN wrench

B. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

R
10 bulb 33-12-08 01A-090
10 bulb 33-12-08 01B-090
10 bulb 33-12-08 01C-090

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-12-00-710-001 Operational Test of the General Illumination


33-12-11-991-001 Fig. 401



EFF :

ALL  33-12-11

Page 405
Aug 01/07
 
IAC 
3. __________
Job Set-up

Subtask 33-12-11-865-056

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CKPT/DOME 1LE H08
122VU LIGHTING/CKPT/DOME 3LE Y06

4. Procedure
_________

(Ref. Fig. 401/TASK 33-12-11-991-001)

Subtask 33-12-11-160-051

A. Preparation for the installation

(1) Clean the component interface and/or the adjacent area.

(2) Make an inspection of the component interface and/or the adjacent


area.

Subtask 33-12-11-420-053

B. Installation of the bulb

(1) Install the bulb (10).

(2) Install the ceiling panel (211CC for the Captain Dome Lights and
212CC for the F/O Dome Lights) with an ALLEN wrench.

Subtask 33-12-11-420-054

C. Installation of the dome light box

(1) Remove the blanking caps of the disconnected electrical connector (1)
and the socket (2).

(2) Install the dome light box.



EFF :

ALL  33-12-11

Page 406
Nov 01/06
R  
IAC 
(3) Tighten the four screws (4) and washers (3) that attach the dome
light box.

(4) Connect the electrical connector (1) to the socket (2).

(5) Install the ceiling panel (211CC for the Captain Dome Lights and
212CC for the F/O Dome Lights) with an ALLEN wrench.

Subtask 33-12-11-420-055

D. Installation of the socket

(1) Install the socket (9) in its housing.

(2) Attach the socket (9) with the washer (8) and the nut (7).

(3) Connect the power supply cable (11) and attach it with the screw (12)
and the washer (13).

(4) Put the plate (6) in position. Hold it in this position.

(5) Tighten the two screws (14) and the two screws (5) with their nuts
(15) that attach the plate (6).

(6) Install the bulb (10).

(7) Install the ceiling panel (211CC for the Captain Dome Lights and
212CC for the F/O Dome Lights) with an ALLEN wrench.

Subtask 33-12-11-865-057

E. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
R

R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R 49VU LIGHTING/EMER LT/CKPT/DOME 1LE H08
R 122VU LIGHTING/CKPT/DOME 3LE Y06

Subtask 33-12-11-710-052

F. Do the operational test of the cockpit dome light (Ref. TASK 33-12-00-
710-001).



EFF :

ALL  33-12-11

Page 407
Nov 01/07
 
IAC 
5. Close-up
________

Subtask 33-12-11-942-051

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-12-11

Page 408
Nov 01/07
 
IAC 
LIGHT - READING (25LE,26LE,29LE) - REMOVAL/INSTALLATION
_______________________________________________________

TASK 33-12-12-000-001

Removal of the Reading Light (25LE, 26LE, 29LE)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-12-12-991-001 Fig. 401


33-12-12-991-002 Fig. 402



EFF :

001-012, 014-027,  33-12-12

Page 401
Config-1 Feb 01/96
 
IAC 
3. __________
Job Set-up

Subtask 33-12-12-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 25LE
122VU LIGHTING/FLOOD/CAPT/SIDE 5LE Z05
FOR 26LE
122VU LIGHTING/FLOOD/F/O/SIDE 4LE Z06
FOR 29LE
122VU LIGHTING/FLOOD/CTR INST/PNL 2LE Z04

4. Procedure
_________

Subtask 33-12-12-020-050

R A. Removal of the Reading Light Bulb

(1) Captain / First Officer reading lights


(Ref. Fig. 401/TASK 33-12-12-991-001)

(a) Lift the reading light (2) out of its housing (1) and put it
against its stop.

(b) Push the button under the reading light (2) and remove the light
unit (4).

(c) Release the two catches that attach the socket (5) in the light
unit (4) and remove the socket (5).

(d) Remove the bulb (3).

(2) Supplementary reading light


(Ref. Fig. 402/TASK 33-12-12-991-002)

(a) Remove the cap (4) from the reading light body (2) with a
screwdriver.

(b) Remove the bulb (3) from the socket (1).



EFF :

001-012, 014-027,  33-12-12

Page 402
Config-1 May 01/98
 
IAC 
Subtask 33-12-12-020-051

B. Removal of the Reading Lights

(1) Captain / First Officer reading lights


(Ref. Fig. 401/TASK 33-12-12-991-001)

(a) Pull and turn the reading light (12) to get access to its holder
(10).

(b) Remove the four attaching screws (11) and the four washers (7).

(c) Pull the reading light holder (10) out of its housing.

(d) Disconnect the female terminal lugs (8) from the male terminal
lugs (9).

(e) Remove the reading light (12).

(2) Supplementary reading light


(Ref. Fig. 402/TASK 33-12-12-991-002)

(a) Remove the QAD fasteners (5) from the panel (9).

(b) Disconnect the female terminal lugs (6) from the male terminal
lugs (7).

(c) Remove the circlip (10) from the reading light (8).

(d) Remove the reading light (8) .



EFF :

001-012, 014-027,  33-12-12

Page 403
Config-1 Feb 01/96
 
IAC 
Captain / First Officer Reading Lights
Figure 401/TASK 33-12-12-991-001- 12 (SHEET 1)



EFF :

001-012, 014-027,  33-12-12

Page 404
Config-1 Feb 01/96
 
IAC 
Captain / First Officer Reading Lights
Figure 401/TASK 33-12-12-991-001- 22 (SHEET 2)



EFF :

001-012, 014-027,  33-12-12

Page 405
Config-1 Feb 01/96
 
IAC 
Supplementary Reading Light
Figure 402/TASK 33-12-12-991-002- 12 (SHEET 1)



EFF :

001-012, 014-027,  33-12-12

Page 406
Config-1 Feb 01/96
 
IAC 
Supplementary Reading Light
Figure 402/TASK 33-12-12-991-002- 22 (SHEET 2)



EFF :

001-012, 014-027,  33-12-12

Page 407
Config-1 Feb 01/96
 
IAC 
TASK 33-12-12-400-001

Installation of the Reading Light (25LE, 26LE, 29LE)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

3 bulb 33-12-12 01 -040


3 bulb 33-12-12 02 -020

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-12-00-710-001 Operational Test of the General Illumination


33-12-12-991-001 Fig. 401
33-12-12-991-002 Fig. 402



EFF :

001-012, 014-027,  33-12-12

Page 408
Config-1 Feb 01/96
 
IAC 
3. __________
Job Set-up

Subtask 33-12-12-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 25LE
122VU LIGHTING/FLOOD/CAPT/SIDE 5LE Z05
FOR 26LE
122VU LIGHTING/FLOOD/F/O/SIDE 4LE Z06
FOR 29LE
122VU LIGHTING/FLOOD/CTR INST/PNL 2LE Z04

4. Procedure
_________

Subtask 33-12-12-560-050

A. Preparation for Installation

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

Subtask 33-12-12-420-050

B. Installation of the Reading Light Bulb

(1) Captain / First Officer reading lights


(Ref. Fig. 401/TASK 33-12-12-991-001)

(a) Install a new bulb (3) in the socket (5).

(b) Install the socket (5) in the light unit (4) with the help of the
two catches.

(c) Install the light unit (4) in the reading light (2).

(d) Put back the reading light (2) in its housing (1).

(2) Supplementary reading light


(Ref. Fig. 402/TASK 33-12-12-991-002)

(a) Install a new bulb (3) in the socket (1).



EFF :

001-012, 014-027,  33-12-12

Page 409
Config-1 Feb 01/96
 
IAC 
(b) Install the cap (4) on the reading light body (2).

Subtask 33-12-12-420-051

C. Installation of the Reading Lights

(1) Captain / First Officer reading lights


(Ref. Fig. 401/TASK 33-12-12-991-001)

NOTE : To make installation easier you can open the window.


____

(a) Connect the female terminal lugs (8) to the male terminal lugs
(9).

(b) Install the reading light holder (10) in its housing.

(c) Install the four washers (7) on the screws (11).

(d) Tighten the reading light holder (10) with the four attaching
screws (11) and washers (7).

(e) Put the reading light (12) in its holder (10).

(2) Supplementary reading light


(Ref. Fig. 402/TASK 33-12-12-991-002)

(a) Install the reading light (8) on the panel (9).

(b) Attach the circlip (10) to the reading light (8).

(c) Connect the female terminal lugs (6) to the male terminal lugs
(7).

(d) Tighten the QAD fasteners (5) of the panel (9).

Subtask 33-12-12-865-052

D. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
FOR 25LE
5LE
FOR 26LE
4LE
FOR 29LE
2LE



EFF :

001-012, 014-027,  33-12-12

Page 410
Config-1 Feb 01/96
 
IAC 
Subtask 33-12-12-710-050

E. Do the operational test (Ref. TASK 33-12-00-710-001).

5. Close-up
________

Subtask 33-12-12-942-050

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

001-012, 014-027,  33-12-12

Page 411
Config-1 Feb 01/96
 
IAC 
LIGHT - MAP TABLE (41LE,42LE) - REMOVAL/INSTALLATION
____________________________________________________

TASK 33-12-12-000-002

Removal of the Map Table Lights (41LE, 42LE)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-12-12-991-006 Fig. 401

3. __________
Job Set-up

Subtask 33-12-12-865-053

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 41LE
122VU LIGHTING/FLOOD/CAPT/SIDE 5LE Z05
FOR 42LE
122VU LIGHTING/FLOOD/F/O/SIDE 4LE Z06


R

EFF :

028-099, 101-199, 901-999,  33-12-12

Page 401
Config-2 Feb 01/07
 
IAC 
4. Procedure
_________

(Ref. Fig. 401/TASK 33-12-12-991-006)

Subtask 33-12-12-020-054

A. Removal of the Map Table Light Bulb

(1) Remove the screw (4).

(2) Remove the cover (3) from the support (1).

(3) Remove the bulb (2).


R

EFF :

028-099, 101-199, 901-999,  33-12-12

Page 402
Config-2 Feb 01/07
 
IAC 
Captain/First-Officer Map-Table Lights
Figure 401/TASK 33-12-12-991-006


R

EFF :

028-099, 101-199, 901-999,  33-12-12

Page 403
Config-2 Feb 01/07
 
IAC 
TASK 33-12-12-400-002

Installation of the Map Table lights (41LE, 42LE)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

2 bulb 33-12-01 04 -050

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-12-00-710-001 Operational Test of the General Illumination


33-12-12-991-006 Fig. 401

3. __________
Job Set-up

Subtask 33-12-12-865-054

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 41LE
122VU LIGHTING/FLOOD/CAPT/SIDE 5LE Z05
FOR 42LE
122VU LIGHTING/FLOOD/F/O/SIDE 4LE Z06


R

EFF :

028-099, 101-199, 901-999,  33-12-12

Page 404
Config-2 Feb 01/07
 
IAC 
4. Procedure
_________

(Ref. Fig. 401/TASK 33-12-12-991-006)

Subtask 33-12-12-420-055

A. Installation of the Map Table Light Bulb

(1) Install the new bulb (2)

(2) Install the cover (3) on the support (1).

(3) Install the screw (4).

Subtask 33-12-12-865-055

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
FOR 41LE
5LE
FOR 42LE
4LE

Subtask 33-12-12-710-051

C. Do the operational test (Ref. TASK 33-12-00-710-001).

5. Close-up
________

Subtask 33-12-12-942-051

A. Make sure that the work area is clean and clear of tool(s) and other
items.


R

EFF :

028-099, 101-199, 901-999,  33-12-12

Page 405
Config-2 Feb 01/07
 
IAC 
_________________________________________________________
LIGHT - MAIN AND CENTER INSTRUMENT PANEL (36LE,37LE,38LE)
____________________
REMOVAL/INSTALLATION

TASK 33-12-13-000-001

Removal of the Main Instrument-Panel Lights (36LE, 37LE)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-027,

33-12-13-991-001 Fig. 401

R **ON A/C 028-099, 101-199, 901-999,

33-12-13-991-001-A Fig. 401A



EFF :

ALL  33-12-13

Page 401
Feb 01/07
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-12-13-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CKPT/DOME 1LE H08
122VU LIGHTING/FLOOD/CTR INST/PNL 2LE Z04

4. Procedure
_________

**ON A/C 001-012, 014-027,

(Ref. Fig. 401/TASK 33-12-13-991-001)

R **ON A/C 028-099, 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-12-13-991-001-A)

**ON A/C 001-012, 014-027,

Subtask 33-12-13-020-050

A. Removal of the Captain and F/O Main Instrument-Panel Lights

(1) Loosen the four fasteners (1). During this operation, hold the
blanking plate (3).

(2) Remove the blanking plate (3) from its housing.

(3) Before you remove the bulb (2) it is necessary that you move back the
bulb holder (4).

(4) Remove the bulb (2).



EFF :

ALL  33-12-13

Page 402
Feb 01/07
 
IAC 
Main Instrument-Panel Light
Figure 401/TASK 33-12-13-991-001



EFF :

001-012, 014-027,  33-12-13

Page 403
Feb 01/96
 
IAC 
Main Instrument-Panel Light
Figure 401A/TASK 33-12-13-991-001-A


R

EFF :

028-099, 101-199, 901-999,  33-12-13

Page 404
Feb 01/07
 
IAC 
R **ON A/C 028-099, 101-199, 901-999,

Subtask 33-12-13-020-050-A

A. Removal of the Captain and F/O Main Instrument-Panel Lights

(1) Loosen the four fasteners (1). During this operation, hold the
blanking plate (3).

(2) Remove the blanking plate (3) from its housing.

(3) Before you remove the bulb (2) it is necessary that you move back the
bulb holder (4).

(4) Remove the two screws (7).

(5) Remove the transparent cover (6) from the seal (8).

NOTE : Do not remove the seal (8).


____

(6) Remove the bulb (2).

(7) Remove the six bulbs (5).


R

EFF :

028-099, 101-199, 901-999,  33-12-13

Page 405
Feb 01/07
 
IAC 
**ON A/C ALL

TASK 33-12-13-400-001

Installation of the Main Instrument-Panel Light (36LE, 37LE)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

2 bulb 33-12-13 01 -010


2 bulb 33-12-13 01A-010
2 bulb 33-12-13 01B-010
5 bulbs 33-12-13 01A-090

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-12-00-710-001 Operational Test of the General Illumination

**ON A/C 001-012, 014-027,

33-12-13-991-001 Fig. 401

R **ON A/C 028-099, 101-199, 901-999,

33-12-13-991-001-A Fig. 401A



EFF :

ALL  33-12-13

Page 406
Feb 01/07
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-12-13-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CKPT/DOME 1LE H08
122VU LIGHTING/FLOOD/CTR INST/PNL 2LE Z04

4. Procedure
_________

**ON A/C 001-012, 014-027,

(Ref. Fig. 401/TASK 33-12-13-991-001)

R **ON A/C 028-099, 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-12-13-991-001-A)

**ON A/C ALL

Subtask 33-12-13-560-052

A. Preparation for Installation

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.



EFF :

ALL  33-12-13

Page 407
Feb 01/07
 
IAC 
**ON A/C 001-012, 014-027,

Subtask 33-12-13-420-050

B. Installation of the Captain and F/O Main Instrument-Panel Lights

(1) Move back the bulb holder (4) and hold it in its position.

(2) Install a new bulb (2) on the Captain and F/O sides.

(3) Put the blanking plate (3) in position opposite its housing. Hold it
in this position.

(4) Attach the blanking plate (3) with the four fasteners (1).

R **ON A/C 028-099, 101-199, 901-999,

Subtask 33-12-13-420-050-A

B. Installation of the Captain and F/O Main Instrument-Panel Lights

(1) Move back the bulb holder (4) and hold it in its position.

(2) Install a new bulb (2) on the Captain and F/O sides.

(3) Install the six new bulbs (5).

(4) Install the transparent cover (6) in position on the seal (8).

(5) Install the two screws (7).

(6) Put the blanking plate (3) in position opposite its housing. Hold it
in this position.

(7) Attach the blanking plate (3) with the four fasteners (1).

**ON A/C ALL

Subtask 33-12-13-865-052

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LE, 2LE



EFF :

ALL  33-12-13

Page 408
Feb 01/07
 
IAC 
Subtask 33-12-13-710-050

D. Do the operational test of Main Instrument-Panel Light (Ref. TASK 33-12-


00-710-001).

5. Close-up
________

Subtask 33-12-13-942-050

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-12-13

Page 409
Feb 01/96
 
IAC 
TASK 33-12-13-000-002

Removal of the Main Instrument-Panel Center-Light (38LE)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-12-13-991-002 Fig. 402

3. __________
Job Set-up

Subtask 33-12-13-865-056

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
49VU LIGHTING/EMER LT/CKPT/DOME 1LE H08
122VU LIGHTING/FLOOD/CTR INST/PNL 2LE Z04



EFF :

ALL  33-12-13

Page 410
Aug 01/06
 
IAC 
R **ON A/C ALL

4. Procedure
_________

(Ref. Fig. 402/TASK 33-12-13-991-002)

Subtask 33-12-13-020-053

A. Removal of the Main Instrument-Panel Center-Light

(1) Loosen the three fasteners (1). During this operation, hold the
blanking plate (2).

(2) Let the blanking plate (2) open downwards.

(3) Remove the two fasteners (3) that attach the optical body (4) with
the defective bulb (6).

(4) Pull the optical body (4).

(5) Laterally push the contact spring (5) and remove the socket (7).

(6) Remove the defective bulb (6).



EFF :

ALL  33-12-13

Page 411
May 01/06
 
IAC 
Main Instrument-Panel Center-Light
Figure 402/TASK 33-12-13-991-002



EFF :

ALL  33-12-13

Page 412
Feb 01/96
 
IAC 
TASK 33-12-13-400-002

Installation of the Main Instrument-Panel Center-Light (38LE)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

6 bulb 33-12-13 03A-010


6 bulb 33-12-13 03B-010

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-12-00-710-001 Operational Test of the General Illumination


33-12-13-991-002 Fig. 402

3. __________
Job Set-up

Subtask 33-12-13-865-057

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
49VU LIGHTING/EMER LT/CKPT/DOME 1LE H08
122VU LIGHTING/FLOOD/CTR INST/PNL 2LE Z04



EFF :

ALL  33-12-13

Page 413
Aug 01/06
 
IAC 
R

4. Procedure
_________

(Ref. Fig. 402/TASK 33-12-13-991-002)

Subtask 33-12-13-560-051

A. Preparation for Installation

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

Subtask 33-12-13-420-053

B. Installation of the Main Instrument-Panel Center-Light

(1) Install a new bulb (6) in its socket (7).

(2) Laterally push the contact spring (5) and install the socket (7).

(3) Install the optical body (4) on its blanking plate (2).

(4) Attach the optical body (4) with the two fasteners (3).

(5) Close the blanking plate (2). Hold it in this position.

(6) Attach the blanking plate (2) with the three fasteners (1).

Subtask 33-12-13-865-058

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LE, 2LE

Subtask 33-12-13-710-052

D. Do the operational test of the Main Instrument Panel Center Light


(Ref. TASK 33-12-00-710-001)

5. Close-up
________

Subtask 33-12-13-942-052

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-12-13

Page 414
Aug 01/06
 
IAC 
LIGHT - CENTER PEDESTAL (27LE) - REMOVAL/INSTALLATION
_____________________________________________________

TASK 33-12-14-000-002

Removal of the Center Pedestal Light (27LE)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-12-14-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-12-14-865-053

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/FLOOD/CTR INST/PNL 2LE Z04



EFF :

ALL  33-12-14

Page 401
Aug 01/06
 
IAC 
R

4. Procedure
_________

(Ref. Fig. 401/TASK 33-12-14-991-001)

Subtask 33-12-14-020-052

A. Removal of the Bulb from the Center Pedestal Light

(1) Remove the lens (1) from the body of the light (3) with a
screwdriver.

(2) Remove the bulb (2) from the socket inside the body of the light (3).

Subtask 33-12-14-020-053

B. Removal of the Center Pedestal Light

(1) Loosen the quick-disconnect fasteners (5) from the panel (7).

(2) Disconnect the female electrical connectors (9) from the male
electrical connectors (8) of the center pedestal light (6).

(3) Remove the circlips (4) from the light (6).

(4) Remove the light.



EFF :

ALL  33-12-14

Page 402
Aug 01/06
 
IAC 
INTENTIONALLY BLANK





 33-12-14

Page 403
Feb 01/96
 
IAC 
Center Pedestal Light
Figure 401/TASK 33-12-14-991-001- 12 (SHEET 1)



EFF :

ALL  33-12-14

Page 404
Feb 01/96
 
IAC 
Center Pedestal Light
Figure 401/TASK 33-12-14-991-001- 22 (SHEET 2)



EFF :

ALL  33-12-14

Page 405
Feb 01/96
 
IAC 
TASK 33-12-14-400-002

Installation of the Center Pedestal Light (27LE)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

2 bulb 33-12-14 01 -020

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-12-00-710-001 Operational Test of the General Illumination


33-12-14-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-12-14-865-054

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/FLOOD/CTR INST/PNL 2LE Z04



EFF :

ALL  33-12-14

Page 406
Aug 01/06
 
IAC 
R

Subtask 33-12-14-941-050

B. Preparation for the Installation

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-12-14-991-001)

Subtask 33-12-14-420-052

A. Installation of the Bulb in the Center Pedestal Light

(1) Install the bulb (2)

(2) Install the lens (1) on the body of the light (3).

Subtask 33-12-14-420-053

B. Installation of the Center Pedestal Light

(1) Install the light (6) on the panel (7).

(2) Install the circlips (4) on the light (6).

(3) Connect the female electrical connectors (9) to the male electrical
connectors (8).

(4) Tighten the quick-disconnect fasteners (5) on the panel (7).

Subtask 33-12-14-865-055

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
2LE

Subtask 33-12-14-710-051

D. Do the operational test of the Center Pedestal Light (Ref. TASK 33-12-00-
710-001).



EFF :

ALL  33-12-14

Page 407
Aug 01/06
 
IAC 
5. Close-up
________

Subtask 33-12-14-942-051

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-12-14

Page 408
Feb 01/96
 
IAC 
_______________________________________________________________________
LIGHT - CONSOLE AND BRIEFCASE (17LE,18LE,19LE,20LE,21LE,22LE,23LE,24LE)
____________________
REMOVAL/INSTALLATION

TASK 33-12-15-000-001

Removal of the Console and Briefcase Light (17LE, 18LE, 19LE, 20LE, 21LE, 22LE,
23LE, 24LE)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-12-15-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-12-15-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/FLOOD/F/O/SIDE 4LE Z06
122VU LIGHTING/FLOOD/CAPT/SIDE 5LE Z05



EFF :

ALL  33-12-15

Page 401
Aug 01/06
 
IAC 
R

4. Procedure
_________

(Ref. Fig. 401/TASK 33-12-15-991-001)

Subtask 33-12-15-020-050

A. Removal of the Light

(1) Remove the cover (3) from its housing (1). To do this, put two
fingers in the covers notches.

(2) Remove the bulb (2) from the cover (3). To do this, pull the bulb.



EFF :

ALL  33-12-15

Page 402
Aug 01/06
 
IAC 
Console and Briefcase Light
Figure 401/TASK 33-12-15-991-001



EFF :

ALL  33-12-15

Page 403
Feb 01/96
 
IAC 
TASK 33-12-15-400-001

Installation of the Console and Briefcase Light (17LE, 18LE, 19LE, 20LE, 21LE,
22LE, 23LE, 24LE)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

2 bulb 33-12-15 01 -010

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-12-00-710-001 Operational Test of the General Illumination


33-12-15-991-001 Fig. 401



EFF :

ALL  33-12-15

Page 404
May 01/06
R  
IAC 
3. __________
Job Set-up

Subtask 33-12-15-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/FLOOD/F/O/SIDE 4LE Z06
122VU LIGHTING/FLOOD/CAPT/SIDE 5LE Z05

Subtask 33-12-15-941-050

B. Aircraft Maintenance Configuration

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-12-15-991-001)

Subtask 33-12-15-420-050

A. Installation of the Light

(1) Install the bulb (2)

NOTE : Make sure that the bulb (2) is in the correct position in the
____
cover (3).

(2) Put the cover (3) in position in the housing (1).

NOTE : Make sure that the cover (3) is locked correctly.


____

Subtask 33-12-15-865-052

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
5LE, 4LE



EFF :

ALL  33-12-15

Page 405
Aug 01/06
 
IAC 
Subtask 33-12-15-710-050

C. Test

(1) Do the operational test of the light (Ref. TASK 33-12-00-710-001).

5. Close-up
________

Subtask 33-12-15-942-050

A. Aircraft Maintenance Configuration

(1) Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-12-15

Page 406
Aug 01/06
R  
IAC 
RHEOSTAT - FLOODLIGHT (28LE,35LE) - REMOVAL/INSTALLATION
________________________________________________________

TASK 33-12-17-000-001

Removal of the Rheostat - Flood Light (28LE, 35LE)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-12-17-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-12-17-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
49VU LIGHTING/EMER LT/CKPT/DOME 1LE H08
122VU LIGHTING/FLOOD/CTR INST/PNL 2LE Z04



EFF :

ALL  33-12-17

Page 401
Aug 01/06
 
IAC 
R

4. Procedure
_________

(Ref. Fig. 401/TASK 33-12-17-991-001)

Subtask 33-12-17-020-050

A. Removal of the Pedestal Flood-Light Rheostat (28LE)

(1) Loosen the two fasteners (2).

(2) Carefully pull the panel 112VU (1).

(3) Remove the two screws (11) and disconnect the electrical connector
(10).

(4) Put blanking caps on the disconnected electrical connectors.

(5) Loosen the two screws (6) located on the knob (5), do not remove
them.

(6) Remove the knob (5).

(7) Remove the two screws (4) and the placard (3).

(8) Remove the nut (7) and the washer (8).

(9) Remove the rheostat (9).

Subtask 33-12-17-020-051

B. Removal of the Main Panel Flood Light Rheostat (35LE)

(1) Loosen the two fasteners (13).

(2) Carefully pull the panel 111VU (12).

(3) Remove the two screws (22) and disconnect the electrical connector
(21).

(4) Put blanking caps on the disconnected electrical connectors.

(5) Loosen the two screws (17) located on the knob (16), do not remove
them.

(6) Remove the knob (16).

(7) Remove the two screws (15) and the placard (14).



EFF :

ALL  33-12-17

Page 402
Aug 01/06
 
IAC 
Main Panel and Pedestal Flood Light Rheostats
Figure 401/TASK 33-12-17-991-001



EFF :

ALL  33-12-17

Page 403
Feb 01/96
 
IAC 
(8) Remove the nut (18) and the washer (19).

(9) Remove the rheostat (20).



EFF :

ALL  33-12-17

Page 404
Feb 01/96
 
IAC 
TASK 33-12-17-400-001

Installation of the Rheostat - Flood Light (28LE, 35LE)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

9 rheostat 33-12-08 02 -130


20 rheostat 33-12-08 02 -140

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-12-00-710-001 Operational Test of the General Illumination


33-12-17-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-12-17-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
49VU LIGHTING/EMER LT/CKPT/DOME 1LE H08
122VU LIGHTING/FLOOD/CTR INST/PNL 2LE Z04



EFF :

ALL  33-12-17

Page 405
Aug 01/06
 
IAC 
R

4. Procedure
_________

(Ref. Fig. 401/TASK 33-12-17-991-001)

Subtask 33-12-17-420-050

A. Installation of the Pedestal Flood-Light Rheostat (28LE)

(1) Do an inspection of the component interface and/or the adjacent area.

(2) Install a new rheostat (9) through the hole of the panel 112VU (9).

(3) Install the washer (8) and tighten the nut (7).

(4) Put the placard (3) in position on the panel 112VU (1) and hold it in
this position.

(5) Attach the placard (3) with the two screws (4).

(6) Install the knob (5). Be careful not to damage the flat of the axle
of the rheostat (9).

(7) Tighten the two screws (6).

(8) Remove the blanking caps from the electrical connectors.

(9) Make sure that the electrical connectors are clean and in the correct
condition.

(10) Install the connector (10) and attach it with the two screws (11) on
the back of the rheostat (9).

(11) Install the panel 112VU (1) with the two fasteners (2).

Subtask 33-12-17-420-051

B. Installation of the Main-Panel Flood-Light Rheostat (35LE)

(1) Do an inspection of the component interface and/or the adjacent area.

(2) Install a new rheostat (20) through the hole of the panel 111VU (12).

(3) Install the washer (19) and tighten the nut (18).

(4) Put the placard (14) in position on the panel 111VU (12) and hold it
in this position.



EFF :

ALL  33-12-17

Page 406
Aug 01/06
 
IAC 
(5) Attach the placard (14) with the two screws (15).

(6) Install the knob (16). Be careful not to damage the flat of the axle
of the rheostat (20).

(7) Tighten the two screws (17).

(8) Remove the blanking caps from the electrical connectors.

(9) Make sure that the electrical connectors are clean and in the correct
condition.

(10) Install the connector (21) and attach it with the two screws (22) on
the back of the rheostat (20).

(11) Install the panel 111VU (12) with the two fasteners (13).

Subtask 33-12-17-865-052

C. Preparation for the Test


Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LE, 2LE

Subtask 33-12-17-710-050

D. Test
Do the operational test of the general illumination (Ref. TASK 33-12-00-
710-001).

5. Close-up
________

Subtask 33-12-17-942-050

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-12-17

Page 407
Feb 01/96
 
IAC 
RHEOSTAT - MAP TABLE LIGHT (39LE,40LE) - REMOVAL/INSTALLATION
_____________________________________________________________

TASK 33-12-18-000-001

Removal of the Map Table Light Rheostats (39LE, 40LE)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-12-18-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-12-18-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 41LE
122VU LIGHTING/FLOOD/CAPT/SIDE 5LE Z05
FOR 42LE
122VU LIGHTING/FLOOD/F/O/SIDE 4LE Z06


R

EFF :

028-099, 101-199, 901-999,  33-12-18

Page 401
Feb 01/07
 
IAC 
4. Procedure
_________

(Ref. Fig. 401/TASK 33-12-18-991-001)

Subtask 33-12-18-020-050

A. Removal of the Map Table Light and Control Box

(1) Remove the control box:

(a) Remove the button (5) of the rheostat.

(b) Remove the screw (6) and the cover (4).

(c) Disconnect the cable (2).

(d) Remove the four attaching screws (14) and the four washers (13).

(e) Pull the control box holder (12) out of its housing.

(f) Disconnect the female terminal lugs (16) from the male terminal
lugs (15).

(2) Remove the Map Table Light:

(a) Remove the screw (10).

(b) Remove the cover (9).

(c) Remove the screws (7) and (8).

(d) Remove the support (11) of the reading light with the cable (2).


R

EFF :

028-099, 101-199, 901-999,  33-12-18

Page 402
Feb 01/07
 
IAC 
INTENTIONALLY BLANK


R



 33-12-18

Page 403
Feb 01/07
 
IAC 
Captain/First Officer Contol Box of the Reading Lights
Figure 401/TASK 33-12-18-991-001- 12 (SHEET 1)


R

EFF :

028-099, 101-199, 901-999,  33-12-18

Page 404
Feb 01/07
 
IAC 
Captain/First Officer Contol Box of the Reading Lights
Figure 401/TASK 33-12-18-991-001- 22 (SHEET 2)


R

EFF :

028-099, 101-199, 901-999,  33-12-18

Page 405
Feb 01/07
 
IAC 
TASK 33-12-18-400-001

Installation of the Map Table Light Rheostats (39LE, 40LE)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-12-00-710-001 Operational Test of the General Illumination


33-12-18-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-12-18-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 41LE
122VU LIGHTING/FLOOD/CAPT/SIDE 5LE Z05
FOR 42LE
122VU LIGHTING/FLOOD/F/O/SIDE 4LE Z06


R

EFF :

028-099, 101-199, 901-999,  33-12-18

Page 406
Feb 01/07
 
IAC 
4. Procedure
_________

(Ref. Fig. 401/TASK 33-12-18-991-001)

Subtask 33-12-18-420-050

A. Installation of the Map Table Light Control Box

(1) Install the Map Table light:

NOTE : To make installation easier you can open the window.


____

(a) Install the cable (2) through the hole of the support (1) and put
the support (11) in position.

(b) Install the screws (8) and (7).

(c) Install the cover (9) with the screw (10).

(2) Install the Control-Box:

NOTE : To make installation casier you can open the window.


____

(a) Connect the female terminal lugs (16) to the male terminal lugs
(15).

(b) Install the cable (2) through the hole of the control box holder
(12).

(c) Install the four washers (13) on the screws (14).

(d) Tighten the control box holder (12) with the four attaching
screws (14) and washers (13).

(e) Connect the cable (2).

NOTE : Respect the colours when you connect the wires.


____

(f) Install the cover (4) with the screw (6).

(g) Install the button of the rheostat (5).


R

EFF :

028-099, 101-199, 901-999,  33-12-18

Page 407
Feb 01/07
 
IAC 
Subtask 33-12-18-865-052

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
FOR 41LE
5LE
FOR 42LE
4LE

Subtask 33-12-18-710-050

C. Do the operational test (Ref. TASK 33-12-00-710-001).

5. Close-up
________

Subtask 33-12-18-942-050

A. Make sure that the work area is clean and clear of tool(s) and other
items.


R

EFF :

028-099, 101-199, 901-999,  33-12-18

Page 408
Feb 01/07
 
IAC 
INSTRUMENT AND PANEL INTEGRAL LIGHTING - DESCRIPTION AND OPERATION
__________________________________________________________________

1. _______
General
The instrument and panel integral lighting permit the crew to read the
indications on these panels and instruments during night flights or flights
in stormy conditions.

2. Component
__________________
Location
(Ref. Fig. 001)

-------------------------------------------------------------------------------
FIN I FUNCTIONAL DESIGNATION I PANELIZONEIACCESS I ATA
I I I I DOOR I REF.
-------------------------------------------------------------------------------
2LF SW-INT LT, STBY COMPASS 25VU 210
6LF CONTROLLER-LIGHTING 210 33-13-51
7LF POT-INT LT/OVHD INTEG LT 25VU 210
16LF CONTROLLER-LIGHTING 212 811 33-13-51
17LF POT-INTEG LT/MAIN PNL & PED 111VU 211
30LF CONTROLLER-LIGHTING 212 811 33-13-51
2FN COMPASS STANDBY 210



EFF :

ALL  33-13-00

Page 1
Feb 01/96
 
IAC 
R Instrument and Panel Integral Lighting - Component Location
R Figure 001



EFF :

ALL  33-13-00

Page 2
Aug 01/96
 
IAC 
3. System
__________________
Description
The integral lighting installed on the panels and the instruments has
miniature lamps. These lamps are supplied by an alternating current with
variable voltage from 0 to 5 volts.
Lighting controllers deliver this alternating current.
These lighting controllers generate a low voltage current source with high
intensity from the 115V - 400Hz voltage.
A 470 ohms potentiometer provides the continuous adjustment of the output
voltage between 0 and 5 efficient volts.
This output voltage is independent from the load.
The table below shows the main characteristics and the function of each
lighting controller.

-------------------------------------------------------------------------------
| | Lighting | Supply | Adjustment |
| Instrument | Controller | | Potentiometer|
| and Panel |-------------------------------|------------|--------------|
| Integral | Lighting | Maximum | Number | Circuit | Electrical |
| Lighting | Controller | Output | of | Breaker | Identifier |
| | Identifier | Power | Fuses | Identifier | |
|-----------------|------------|---------|--------|------------|--------------|
| Overhead Panel | 6LF | 180VA | 6 | 3LF | 7LF |
|-----------------|------------|---------|--------|------------|--------------|
| Captain, First | | | | | |
| Officer Main | | | | | |
| Instrument | | | | | |
| Panels | 16LF | 180VA | 6 | 4LF | 17LF |
| Center | | | | | |
| Instrument Panel| | | | | |
| Center Pedestal | | | | | |
| Side Consoles | | | | | |
|-----------------|------------|---------|--------|------------|--------------|
| Glareshields | 30LF | 25VA | 3 | 5LF | 38LE |
| | | + 45VA | | | |
-------------------------------------------------------------------------------

R A. Instrument and Panel Integral Lighting


R (Ref. Fig. 002)
R This lighting system has several circuits:

R (1) Overhead panel integral lighting


R It comprises:
R - a circuit breaker 3LF. The normal busbar 103XP supplies
R 115VAC/400Hz to this circuit breaker (panel 122VU),
R - a potentiometer 7LF used for the adjustment of the integral
R lighting brightness (panel 25VU),



EFF :

ALL  33-13-00

Page 3
Aug 01/96
 
IAC 
R Instrument and Panel Integral Lighting - Schematic
R Figure 002



EFF :

ALL  33-13-00

Page 4
Aug 01/96
 
IAC 
R - a lighting controller 6LF. Its 6 outputs provide the integral
R lighting of the placards and the instruments on the overhead panel.

R (2) Integral lighting of instrument panels, consoles and center pedestal


R It comprises:
R - a circuit breaker 4LF. The normal busbar 103XP supplies
R 115VAC/400Hz to this circuit breaker (panel 122VU),
R - a potentiometer 17LF which provides the adjustment of the integral
R lighting brightness (panel 111VU),
R - a lighting controller 16LF located close to the First Officer
R pedals.
R Its 6 outputs provide the integral lighting of the placards and the
R instruments on the instrument panels and the pedestal.

R (3) Glareshield integral lighting


R It comprises:
R - a circuit breaker 5LF. The normal busbar 103XP supplies this
R circuit breaker with 115VAC/400Hz (panel 122VU),
R - two linear or rotary potentiometers mounted in light 38LE. One is
R for the glareshield integral lighting, the other one for the FCU
R display lighting,
R - a lighting controller 30LF located close to 16LF. Three outputs
R provide instrument display and panel integral lighting.

R B. Standby Compass Lighting


The lighting system of the standby compass comprises:
- a circuit breaker 1LF. The busbar 401PP supplies this circuit breaker
with 28VDC (panel 49VU),
- a STBY COMPASS switch 2LF. It has 2 positions and controls the standby
compass lighting (panel 25VU),
- a foldable standby compass.



EFF :

ALL  33-13-00

Page 5
Aug 01/96
 
IAC 
INSTRUMENT AND PANEL INTEGRAL LIGHTING - ADJUSTMENT/TEST
________________________________________________________

TASK 33-13-00-710-001

Operational Test of the Instrument and Panel Integral Lighting

1. __________________
Reason for the Job

Make sure that the instrument and panel integral-lighting operates


correctly.

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-13-00-860-051

A. Aircraft Maintenance Configuration

(1) Energize the aircraft electrical circuits


(Ref. TASK 24-41-00-861-002).

(2) Pull the STANDBY COMPASS out.



EFF :

ALL  33-13-00

Page 501
Aug 01/06
R  
IAC 
Subtask 33-13-00-865-050

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-099,

49VU LIGHTING/STBY/COMP/LIGHT 1LF H04

R **ON A/C 101-199, 901-999,

49VU LIGHTING/ICE AND STBY/COMP/LIGHT 1LF H04

**ON A/C ALL

122VU LIGHTING/INSTL LT/GLARE/SHLD 5LF Y05


122VU LIGHTING/INSTL LT/MAIN INST/PNL AND/PED 4LF Y04
122VU LIGHTING/INSTL LT/OVHD/PNL 3LF Y03

4. Procedure
_________

Subtask 33-13-00-710-050

A. Operational Test of the Instrument and Panel Integral Lighting

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the panel 25VU: In zone 210:


- set the STBY COMPASS selector - the integral lighting of the standby
switch to STBY. compass comes on with 100 %
brightness.

- set the selector switch to OFF. - the integral lighting of the standby
compass goes off.



EFF :

ALL  33-13-00

Page 502
Feb 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
2. On the panel 111VU: On the main instrument panels (Captain
- turn the INTEG LT/MAIN PNL & and F/O), the center instrument panel,
PED rheostat from OFF to BRT. the center pedestal and the side
consoles:
- the instrument and panel
integral-lighting gets brighter when
you turn the rheostat to BRT.

- turn the rheostat from BRT to - the brightness of the instrument and
OFF. panel integral-lighting gets dimmer
step by step.

3. On the panel 25VU: On the overhead panel:


- turn the OVHD INTEG LT rheostat - the integral lighting gets brighter
from OFF to BRT. when you turn the rheostat to BRT.

- turn the rheostat from BRT to - the brightness of the integral


OFF. lighting gets dimmer step by step.

4. On the glareshield 13VU: On the glareshield and the FCU:


- move the rheostat cursors. - the integral lighting gets brighter
when you turn the rheostat to BRT.

- move the rheostat cursors to - the integral lighting gets dimmer


their initial position. step by step.

5. Close-up
________

Subtask 33-13-00-860-050

A. Put the aircraft back to its initial configuration.

(1) Push the STANDBY COMPASS back to its initial position.

(2) Put the system back to the serviceable condition.

(3) De-energize the aircraft electrical circuits


(Ref. TASK 24-41-00-862-002).



EFF :

ALL  33-13-00

Page 503
Aug 01/06
R  
IAC 
______________________________________________________________________________
PLATE - INT LIGHTED IDENT, 11VU (18LF,19LF,20LF,21LF,22LF,23LF,24LF,26LF,35LF,
36LF) - REMOVAL/INSTALLATION
____________________________

TASK 33-13-41-000-001

Removal of the Integrally-Lighted Identification Plate

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

27-41-41-000-001 Removal of the Control Mechanism-Pitch Trim


76-11-41-000-040 Removal of the Throttle Control Lever Assembly
76-11-41-000-041 Removal of the Throttle Control Lever Assembly
R ESPM 204521
R IPC 761208
33-13-41-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-13-41-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/INSTL LT/MAIN INST/PNL AND/PED 4LF Y04



EFF :

ALL  33-13-41

Page 401
May 01/07
 
IAC 
4. Procedure
_________

(Ref. Fig. 401/TASK 33-13-41-991-001)

Subtask 33-13-41-020-050

A. Removal of the Integrally Lighted Identification Plate 19LF, 20LF

(1) Remove the wheels (1) and the indicators (2) (Ref. TASK 27-41-41-000-
001).

(2) Remove the screws (5).

(3) Remove the integrally lighted identification plate (4).

**ON A/C 001-012, 014-099,

Subtask 33-13-41-020-054

B. Removal of the Integrally-Lighted Identification Plate 21LF

(1) Remove the integrally-lighted identification plate (Ref. TASK 76-11-


41-000-041).

R **ON A/C 101-199, 901-999,

Subtask 33-13-41-020-054-A

B. Removal of the Integrally-Lighted Identification Plate 21LF

(1) Remove the integrally-lighted identification plate (Ref. TASK 76-11-


41-000-040).

**ON A/C ALL

Subtask 33-13-41-020-055

C. Removal of the Integrally-Lighted Identification Plate (18LF)

(1) Loosen the four quarter-turn fasteners (9).

(2) Pull the SWITCHING panel 8VU (8).

(3) Remove the four screws (6).



EFF :

ALL  33-13-41

Page 402
Feb 01/07
 
IAC 
(4) Remove the integrally-lighted identification plate (7).

Subtask 33-13-41-020-056

D. Removal of the Integrally-Lighted Identification Plates (23LF and 24LF)

(1) Loosen the two quarter-turn fasteners (13) and (16).

(2) Pull the FLOOD LT panel 112VU (12) and the FLOOD LT/INTEG LT panel
111VU (17).

(3) Remove the two screws (10) and (14).

(4) Remove the integrally-lighted identification plates (11) and (15).

Subtask 33-13-41-020-057

E. Removal of the Integrally-Lighted Identification Plate (26LF)

R (1) Disassemble the knobs, the nuts and the washers of the ENG/MASTER 1
R and 2 control switches (2KC and 3KC) (Ref. IPC 761208) (Ref. ESPM
R 204521).

R (2) Loosen the four quarter-turn fasteners (18).

R (3) Pull the ENG panel 115VU (19).

R (4) Remove the three screws (21).

R (5) Remove the integrally-lighted identification plate (20).

Subtask 33-13-41-020-058

F. Removal of the Integrally-Lighted Identification Plate (22LF)

(1) Loosen the four quarter-turn fasteners (22).

(2) Pull the RUD TRIM/PARKING BRK panel 110VU (23).

(3) Remove the four screws (25).

(4) Remove the integrally-lighted identification plate (24).

Subtask 33-13-41-020-059

G. Removal of the Integrally-Lighted Identification Plates (35LF and 36LF)

(1) Remove the four screws (26).

(2) Pull the GEAR panel (27).



EFF :

ALL  33-13-41

Page 403
May 01/07
 
IAC 
R Integrally Lighted Identification Plate
R Figure 401/TASK 33-13-41-991-001- 12 (SHEET 1)



EFF :

ALL  33-13-41

Page 404
Nov 01/04
 
IAC 
R Integrally Lighted Identification Plate
R Figure 401/TASK 33-13-41-991-001- 22 (SHEET 2)



EFF :

ALL  33-13-41

Page 405
Nov 01/04
 
IAC 
(3) Remove the four screws (30).

(4) Remove the integrally-lighted identification plates (28) and (29).



EFF :

ALL  33-13-41

Page 406
Feb 01/07
R  
IAC 
TASK 33-13-41-400-001

Installation of the Integrally-Lighted Identification Plate

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

27-41-41-400-001 Installation of the Control Mechanism-Pitch Trim


33-13-00-710-001 Operational Test of the Instrument and Panel Integral
Lighting
76-11-41-400-040 Installation of the Throttle Control Lever Assembly
76-11-41-400-041 Installation of the Throttle Control Lever Assembly
R ESPM 204521
R IPC 761208
33-13-41-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-13-41-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/INSTL LT/MAIN INST/PNL AND/PED 4LF Y04



EFF :

ALL  33-13-41

Page 407
May 01/07
 
IAC 
4. Procedure
_________

(Ref. Fig. 401/TASK 33-13-41-991-001)

**ON A/C 001-012, 014-099,

Subtask 33-13-41-420-054

A. Installation of the Integrally-Lighted Identification Plate 21LF

(1) Install the integrally-lighted identification plate (Ref. TASK 76-11-


41-400-041).

R **ON A/C 101-199, 901-999,

Subtask 33-13-41-420-054-A

A. Installation of the Integrally-Lighted Identification Plate 21LF

(1) Install the integrally-lighted identification plate (Ref. TASK 76-11-


41-400-040).

**ON A/C ALL

Subtask 33-13-41-420-050

B. Installation of the Integrally Lighted Identification Plate 19LF, 20LF


(Ref. Fig. 401/TASK 33-13-41-991-001)

(1) Locate the integrally lighted identification plate (4).

(2) Install the screw (5).

(3) Install the indicator (2) and the wheel (1) (Ref. TASK 27-41-41-400-
001).

Subtask 33-13-41-420-055

C. Installation of the Integrally-Lighted Identification Plate (18LF)

(1) Put the integrally-lighted identification plate (7) in position on


the SWITCHING panel 8VU (8).

(2) Install and tighten the four screws (6).



EFF :

ALL  33-13-41

Page 408
Feb 01/07
 
IAC 
(3) Tighten the four quarter-turn fasteners (9).

Subtask 33-13-41-420-056

D. Installation of the Integrally-Lighted Identification Plates (23LF and


24LF)

(1) Put the integrally-lighted identification plates (11) and (15) in


position on the FLOOD LT panel 112VU (12) and the FLOOD LT/INTEG LT
panel 111VU (17).

(2) Install and tighten the two screws (10) and (14).

(3) Tighten the two quarter-turn fasteners (13) and (16).

Subtask 33-13-41-420-057

E. Installation of the Integrally-Lighted Identification Plate (26LF)

R (1) Pull the disassembled ENG/MASTER 1 and 2 control switches (2KC and
R 3KC) through the integrally-lighted indentification plate (20).

R (2) Put the integrally-lighted identification plate (20) in position on


the ENG panel 115VU (19).

R (3) Install and tighten the three screws (21).

R (4) Tighten the four quarter-turn fasteners (18).

R (5) Install the washers, the nuts and the knobs of the ENG/MASTER 1 and 2
R control switches (2KC and 3KC) (Ref. IPC 761208) (Ref. ESPM 204521).

Subtask 33-13-41-420-058

F. Installation of the Integrally-Lighted Identification Plate (22LF)

(1) Put the integrally-lighted identification plate (24) in position on


the RUD TRIM/PARKING BRK panel 110VU (23).

(2) Install and tighten the four screws (25).

(3) Tighten the four quarter-turn fasteners (22).



EFF :

ALL  33-13-41

Page 409
May 01/07
 
IAC 
Subtask 33-13-41-420-059

G. Installation of the Integrally-Lighted Identification Plates (35LF and


36LF)

(1) Put the integrally-lighted identification plates (28) and (29) in


position on the GEAR panel (27).

(2) Install and tighten the four screws (30).

(3) Install and tighten the four screws (26).

Subtask 33-13-41-865-052

H. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
4LF

Subtask 33-13-41-710-050

J. Do the operational test (Ref. TASK 33-13-00-710-001).

5. Close-up
________

Subtask 33-13-41-942-050

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-13-41

Page 410
May 01/07
R  
IAC 
PLATE - INT LIGHTED IDENT, 20VU - REMOVAL/INSTALLATION
______________________________________________________

TASK 33-13-42-000-001

Removal of the Integrally-Lighted Identification Plate

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-13-42-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-13-42-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/INSTL LT/OVHD/PNL 3LF Y03



EFF :

ALL  33-13-42

Page 401
Aug 01/06
 
IAC 
R

4. Procedure
_________

(Ref. Fig. 401/TASK 33-13-42-991-001)

Subtask 33-13-42-020-050

A. Removal of the Integrally-Lighted Identification Plate (8LF)

(1) Loosen the six quarter-turn fasteners (1).

(2) Pull the overhead control and indicating panel 21VU (2).

(3) Remove the six screws (3).

(4) Remove the integrally-lighted identification plate (4).

Subtask 33-13-42-020-051

B. Removal of the Integrally-Lighted Identification Plate (9LF)

(1) Loosen the four quarter-turn fasteners (5).

(2) Pull the overhead control and indicating panel 22VU (6).

(3) Remove the four screws (7).

(4) Remove the integrally-lighted identification plate (8).

Subtask 33-13-42-020-052

C. Removal of the Integrally-Lighted Identification Plate (10LF or 34LF)

(1) Loosen the two quarter-turn fasteners (9) or (13).

(2) Pull the FLT CTL panel 24VU (10) or 23VU (14).

(3) Remove the two screws (11) or (15).

(4) Remove the integrally-lighted identification plate (12) or (16).



EFF :

ALL  33-13-42

Page 402
Aug 01/06
 
IAC 
Integrally-Lighted Identification Plate
Figure 401/TASK 33-13-42-991-001



EFF :

ALL  33-13-42

Page 403
Nov 01/05
 
IAC 
Subtask 33-13-42-020-053

D. Removal of the Integrally-Lighted Identification Plates (11LF, 12LF, 13LF


or 14LF)

(1) Loosen the four quarter-turn fasteners (17), (21), (25) or (29).

(2) Pull the overhead control and indicating panel 25VU (18), the AIR
COND panel 30VU (22), the ELEC control panel 35VU (26) or the
HYD/FUEL panel 40VU (30).

(3) Remove the five screws (19), (23), (27) or (31).

(4) Remove the integrally-lighted identification plate (20), (24), (28)


or (32).



EFF :

ALL  33-13-42

Page 404
Nov 01/05
 
IAC 
TASK 33-13-42-400-001

Installation of the Integrally-Lighted Identification Plate

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-13-00-710-001 Operational Test of the Instrument and Panel Integral


Lighting
33-13-42-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-13-42-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/INSTL LT/OVHD/PNL 3LF Y03

4. Procedure
_________

(Ref. Fig. 401/TASK 33-13-42-991-001)

Subtask 33-13-42-420-050

A. Installation of the Integrally-Lighted Identification Plate (8LF)

(1) Put the integrally-lighted identification plate (4) in position on


the overhead control and indicating panel 21VU (2).

(2) Install and tighten the six screws (3).

(3) Push the overhead control and indicating panel 21VU (2) and tighten
the six quarter-turn fasteners (1).



EFF :

ALL  33-13-42

Page 405
Aug 01/06
 
IAC 
Subtask 33-13-42-420-051

B. Installation of the Integrally-Lighted Identification Plate (9LF)

(1) Put the integrally-lighted identification plate (8) in position on


the overhead control and indicating panel 22VU (6).

(2) Install and tighten the four screws (7).

(3) Push the overhead control and indicating panel 22VU (6) and tighten
the four quarter-turn fasteners (5).

Subtask 33-13-42-420-052

C. Installation of the Integrally-Lighted Identification Plates (10LF or


34LF)

(1) Put the integrally-lighted identification plate (12) or (16) in


position on the FLT CTL panel 24VU (10) or 23VU (14).

(2) Install and tighten the two screws (11) or (15).

(3) Push the FLT CTL panel 24VU (10) or 23VU (14) and tighten the two
quarter-turn fasteners (9) or (13).

Subtask 33-13-42-420-053

D. Installation of the Integrally-Lighted Identification Plate (11LF, 12LF,


13LF or 14LF)

(1) Put the integrally-lighted identification plate (20), (24), (28) or


(32) in position on the overhead control and indicating panel 25VU
(18), the AIR COND panel 30VU (22), the ELEC control panel 35VU (26)
or the HYD/FUEL panel 40VU (30).

(2) Install and tighten the five screws (19), (23), (27) or (31).

(3) Push the overhead control and indicating panel 25VU (18), the AIR
COND panel 30VU (22), the ELEC control panel 35VU (26) or the
HYD/FUEL panel 40VU (30) and tighten the four quarter-turn fasteners
(17), (21), (25) or (29).

Subtask 33-13-42-865-052

E. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
3LF



EFF :

ALL  33-13-42

Page 406
Aug 01/06
R  
IAC 
Subtask 33-13-42-710-050

F. Do the operational test of the instrument and panel integral lighting


(Ref. TASK 33-13-00-710-001).

5. Close-up
________

Subtask 33-13-42-942-050

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-13-42

Page 407
Nov 01/05
 
IAC 
CONTROLLER - LIGHTING (6LF,16LF,30LF) - REMOVAL/INSTALLATION
____________________________________________________________

TASK 33-13-51-000-001

Removal of the Lighting Controller (6LF, 16LF, 30LF)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
FOR FIN 6LF
No specific ALLEN wrench
FOR FIN 16LF, 30LF
No specific access platform 1.5 m (4 ft. 11 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-13-51-991-001 Fig. 401



EFF :

ALL  33-13-51

Page 401
Feb 01/96
 
IAC 
3. __________
Job Set-up

Subtask 33-13-51-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 6LF
R
122VU LIGHTING/INSTL LT/OVHD/PNL 3LF Y03
R
FOR 16LF
R
122VU LIGHTING/INSTL LT/MAIN INST/PNL AND/PED 4LF Y04
R
FOR 30LF
R
122VU LIGHTING/INSTL LT/GLARE/SHLD 5LF Y05

Subtask 33-13-51-010-050

B. Get Access

(1) FOR 16LF, 30LF


Put the access platform in position at the zone 121.

(2) Open the access door 811.


FOR 16LF, 30LF
811

(3) FOR 6LF


Remove the ceiling panel 211HC with an ALLEN wrench.



EFF :

ALL  33-13-51

Page 402
Aug 01/06
 
IAC 
4. Procedure
_________

(Ref. Fig. 401/TASK 33-13-51-991-001)

Subtask 33-13-51-020-050

A. Removal of the Lighting Controller

(1) Disconnect the connector (4).

(2) Remove the four screws (3) and the lockwashers (2). During this
operation, hold the lighting controller (1).

(3) Remove the lighting controller (1).

(4) Put blanking caps on the connectors (4) and (5).



EFF :

ALL  33-13-51

Page 403
Aug 01/06
R  
IAC 
Lighting Controller
Figure 401/TASK 33-13-51-991-001



EFF :

ALL  33-13-51

Page 404
May 01/06
R  
IAC 
TASK 33-13-51-400-001

Installation of the Lighting Controller (6LF, 16LF, 30LF)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

FOR FIN 6LF


No specific ALLEN wrench
FOR FIN 16LF, 30LF
No specific access platform 1.5 m (4 ft. 11 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-13-00-710-001 Operational Test of the Instrument and Panel Integral


Lighting



EFF :

ALL  33-13-51

Page 405
May 01/06
R  
IAC 
3. __________
Job Set-up

Subtask 33-13-51-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 6LF
R
122VU LIGHTING/INSTL LT/OVHD/PNL 3LF Y03
R
FOR 16LF
R
122VU LIGHTING/INSTL LT/MAIN INST/PNL AND/PED 4LF Y04
R
FOR 30LF
R
122VU LIGHTING/INSTL LT/GLARE/SHLD 5LF Y05

Subtask 33-13-51-010-051

B. Get Access

(1) FOR 16LF, 30LF


Make sure that the access platform is in position at the zone 121.

(2) Make sure that the access door 811 is open.


FOR 16LF, 30LF
811

(3) FOR 6LF


Make sure that the ceiling panel 211HC is removed.

4. Procedure
_________

Subtask 33-13-51-420-050

A. Installation of the Lighting Controller

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.



EFF :

ALL  33-13-51

Page 406
Aug 01/06
 
IAC 
(3) Remove the blanking caps from the electrical connectors (4) and (5).

(4) Put the lighting controller (1) in position opposite its housing (6).
Hold it in this position.

(5) Install the lighting controller (1) with the lockwashers (2) and the
four screws(3).

Subtask 33-13-51-865-052

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
FOR 6LF
3LF
FOR 16LF
4LF
FOR 30LF
5LF

Subtask 33-13-51-710-050

C. Do the operational test of the lighting controller (Ref. TASK 33-13-00-


710-001)

5. Close-up
________

Subtask 33-13-51-410-050

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) FOR 6LF


Install the ceiling panel 211HC with an ALLEN wrench.

(3) Close the access door 811.


FOR 16LF, 30LF
811

(4) FOR 16LF, 30LF


Remove the access platform(s).



EFF :

ALL  33-13-51

Page 407
Aug 01/06
R  
IAC 
ANNUNCIATOR LIGHT TEST AND DIMMING - DESCRIPTION AND OPERATION
______________________________________________________________

1. _______
General
Bulbs supplied with 5VAC-400Hz are used for the lighting of the sun readable
lights in the cockpit. The current is delivered by the 115V/5V transformers.
Each light is parted in two sections ; each one has two 5V bulbs.
An annunciator light test switch permits illumination of all annunciators
and therefore check of all lights.

2. __________________
Component Location

R **ON A/C 001-012, 014-099,

(Ref. Fig. 001, 002)

-------------------------------------------------------------------------------
FIN I FUNCTIONAL DESIGNATION I PANELIZONEIACCESS I ATA
I I I I DOOR I REF.
-------------------------------------------------------------------------------
1LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
2LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
3LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
4LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
5LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
6LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
7LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
8LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
9LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
10LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
11LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
18LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
19LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
20LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
31LP XFMR-ESS 211 33-14-51
33LP SW-INT LT/ANN LT 25VU 210
34LP P/BSW-LIGHT TEST 108VU 120
35LP XFMR-ESS 211 33-14-51
36LP XFMR-SYS 2 120VU 212 33-14-51
37LP XFRM-SYS 1 120VU 212 33-14-51



EFF :

ALL  33-14-00

Page 1
May 01/06
 
IAC 
Annunciator Light Test and Dimming - Component Location
Figure 001


R

EFF :

001-012, 014-099,  33-14-00

Page 2
May 01/06
 
IAC 
R Annunciator Light Test and Dimming - Component Location
R Figure 001A



EFF :

ALL  33-14-00

Page 3
May 01/05
 
IAC 
Annunciator Light Test and Dimming - Component Location
Figure 002



EFF :

ALL  33-14-00

Page 4
May 01/05
R  
IAC 
**ON A/C ALL

R Post SB 34-1188 For A/C 001-012,014-099,

(Ref. Fig. 001A, 002)

-------------------------------------------------------------------------------
FIN I FUNCTIONAL DESIGNATION I PANELIZONEIACCESS I ATA
I I I I DOOR I REF.
-------------------------------------------------------------------------------
1LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
2LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
3LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
4LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
5LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
6LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
7LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
8LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
9LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
10LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
11LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
12LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
18LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
19LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
20LP BOARD-ANN LT TEST & INTFC 70VU 126 822 33-14-33
31LP XFMR-ESS 211 33-14-51
33LP SW-INT LT/ANN LT 25VU 210
34LP P/BSW-LIGHT TEST 108VU 120
35LP XFMR-ESS 211 33-14-51
36LP XFMR-SYS 2 120VU 212 33-14-51
37LP XFRM-SYS 1 120VU 212 33-14-51

**ON A/C ALL

3. System
__________________
Description
(Ref. Fig. 003)
Miniature lamps (115 mA, 5VAC) are used for the lighting of the annunciator
lights mounted on the panels and instruments in the cockpit.
A relay (system) or internal contacts (case of ON-OFF position indication
pushbutton switches) control illumination of each annunciator light. Four
different busbars:
- AC1 supply: 103XP
- AC2 supply: 202XP
- 115VAC STAT INV BUS: 901XP
- Essential supply: 801XP



EFF :

ALL  33-14-00

Page 5
May 01/06
 
IAC 
Annunciator Light Test and Dimming - Principle Diagram
Figure 003 (SHEET 1)



EFF :

ALL  33-14-00

Page 6
May 01/05
R  
IAC 
Annunciator Light Test and Dimming - Principle Diagram
Figure 003 (SHEET 2)



EFF :

ALL  33-14-00

Page 7
May 01/05
R  
IAC 
R supply the annunciator lights with 5VAC-400Hz through the transformers. In
R the case of emergency supply only busbar 901XP is serviceable.
R The system comprises:

A. Four Identical Transformers


Each one is supplied with 115V-400Hz.
Each one is connected to a different busbar.
They supply 5VAC-400Hz for the annunciator lights installed on the
overhead panel and on instrument panel and 6.3V voltage (full wave
rectified) to supply the AUTO LAND, MASTER WARNING and CAUTION lights and
Audio Control Panels (ACP).
The secondary winding of each transformer has:
- 7x5VAC outputs mounted in parallel; each one is protected by a delayed
action fuse set at 4A,
- 2x6.3V outputs protected by the same type of fuse.
The primary winding of each transformer has two inputs to get the correct
dimming level (DIM position).
If the 115V supply is switched over to either input we obtain at the
secondary winding:
- the 5VAC (BRT position),
- the 3VAC (DIM position),
- the 6.3VAC (BRT position) or 4.3VAC for rectified voltages (DIM
position). The transformers 36LP and 37LP are housed in the panel 120VU
and transformers 31LP and 35LP are mounted on the overhead panel.

B. Five Circuit Breakers


- busbar 103XP (AC1) supplies transformer 37LP through the circuit
breaker 26LP located on the circuit breaker panel 122VU,
- busbar 202XP (AC2) supplies transformer 36LP through the circuit
breaker 27LP located on the circuit breaker panel 122VU,
- busbar 801XP supplies transformer 31LP through the circuit breaker 29LP
located on the overhead panel 49VU,
- busbar 801XP supplies transformer 35LP through the circuit breaker 29LP
and the busbar 901XP provides emergency supply through the circuit
breaker 28LP located on the circuit breaker panel 122VU,
- busbar 206PP supplies the annunciator light test relay coils.

C. Switch 33LP
A switch with 3 positions: DIM, BRT, TEST is located on the overhead
control and indicating panel 25VU.

D. Fourteen Annunciator Light Test and Interface Boards


They are located in the avionics compartment in the annunciator light
test unit 70VU:
- 4 are associated with the annunciator lights supplied by the AC1
system.
They are identified by FINs 1LP to 4LP.



EFF :

ALL  33-14-00

Page 8
May 01/05
 
IAC 
- seven are associated with the annunciator lights supplied by the
essential generation. They are identified by FINs 5LP to 11LP.
Three are associated with the annunciator lights supplied by the AC2
generation.
They are identified by FINs 18LP to 20LP.
Each board comprises:
- 2 relays supplied by busbar 206PP with 28VDC through circuit breaker
30LP located on the rear circuit breaker panel 122VU.
These 2 relays serve for the annunciator light tests when the switch
33LP is in the TEST position.
- 10 relays supplied by the various A/C systems with 28VDC. They supply
the annunciator light with 5VAC whereas the system data are supplied
with 28VDC.

E. Four-Stage Relays
They are located in the relay box 103VU. They all are identified with a
TEST placard. They serve for the test of the equipment annunciator lights
(high intensity) or of other annunciator lights (ON - OFF).
The busbar 206PP supplies 28VDC to the coil of these relays through the
circuit breaker 30LP located on the rear circuit breaker panel 122VU.

4. __________________________________
Operational/Control and Indicating
R
R (Ref. Fig. 004)

R A. Annunciator Light Test for the External Power Panel 108VU


R The LIGHT TEST pushbutton switch 34LP on the panel 108VU serves to test
R the EXT PWR/NOT IN USE, EXT PWR/AVAIL, COCKPIT CALL, APU FIRE and ADIRU &
R AVNCS VENT indicator lights.
R The ADIRU & AVNCS VENT caution light is supplied from the 28VDC HOT BUS
R 704PP through the circuit breaker 6FP1 located on the circuit breaker
R panel 105VU.
R The EXT PWR/NOT IN USE, EXT PWR/AVAIL, COCKPIT CALL and APU FIRE
R indicator lights are supplied from the 28VDC BUSBAR 1IWPP through the
R circuit breaker 4XG located on the circuit breaker panel 122VU.
R If ground power is not available, only the ADIRU & AVNCS VENT caution
R light can be tested.
R If ground power is available, the EXT PWR/NOT IN USE, EXT PWR/AVAIL,
R COCKPIT CALL, APU FIRE and ADIRU & AVNCS VENT indicator lights can be
R tested.



EFF :

ALL  33-14-00

Page 9
May 01/05
 
IAC 
Control and Indicating-Panel 108VU
Figure 004



EFF :

ALL  33-14-00

Page 10
May 01/05
 
IAC 
ANNUNCIATOR LIGHT TEST AND DIMMING - ADJUSTMENT/TEST
____________________________________________________

TASK 33-14-00-710-001

R Operational Test of the Lights

1. __________________
Reason for the Job

Refer to the MPD TASK: 331400-01


Make sure that the annunciator lights operate correctly.
Make sure that the dimming circuit of the annunciator lights operates
correctly

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
APU
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-14-00-860-050

A. Aircraft Maintenance Configuration

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002) or (Ref. TASK 24-41-00-861-002):
R - If you energize the aircraft electrical circuits from the external
R power (Ref. TASK 24-41-00-861-002), do the test given in Para. 4.B.
- If you energize the aircraft electrical circuits from the APU
(Ref. TASK 24-41-00-861-002), do the test given in Para. 4.C.

(2) On the Captain and F/O instrument panels, the overhead panel, the
glareshield set some annunciator lights (warning or indicator lights)
to the operative position.

(3) On the center pedestal 11VU and overhead panel 20VU, on all the Radio
Management Panels (RMPs), set the ON/OFF switch to the ON position.



EFF :

ALL  33-14-00

Page 501
Aug 01/07
 
IAC 
Subtask 33-14-00-865-050

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/XFMR/115V.5V/ESS BUS 29LP H03
105VU ADIRS/ADIRU1/28VDC 6FP1 C02
122VU ELEC/EXT PWR/LT CLT/AVAIL 4XG X31
122VU LIGHTING/TST/BOARD/SPLY 30LP X06
122VU LIGHTING/ANN LT SPLY/XFMR/BUS 2 27LP X05
122VU LIGHTING/ANN LT SPLY/XFMR/BUS 1 26LP X04
122VU LIGHTING/ANN LT SPLY/XFMR/STAT INV 28LP X03

4. Procedure
_________

Subtask 33-14-00-710-050

A. Do the annunciator light test in the cockpit

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the panel 25VU: On the panels located in the cockpit:


R - put the ANN LT switch in the - The annunciator lights on the
R TEST position. different panels come on fully
R bright.
R
R - The item lights of equipment come on
R fully bright.
R - The ACP lights come on dim.

- put the ANN LT switch in the - all the annunciator lights go off.
BRT position. This does not include the annunciator
lights that come on during the job
set-up.

- put the ANN LT switch in the - the annunciator lights that come on
DIM position. during the job set-up get dimmer.

- put the ANN LT switch in the - the annunciator lights that come on
BRT position during the job set-up get brighter.



EFF :

ALL  33-14-00

Page 502
May 01/08
 
IAC 
R Subtask 33-14-00-710-054

R B. Do the annunciator light test for the EXT PWR panel 108VU with the
R external power

R -------------------------------------------------------------------------------
R ACTION RESULT
R -------------------------------------------------------------------------------

R On the panel 108VU: On the panel 108VU:


R - push the LIGHT TEST pushbutton - the EXT PWR/NOT IN USE indicator
R switch. light comes on
R - the COCKPIT CALL indicator light
R comes on
R - the APU FIRE indicator light comes on
R - the ADIRU & AVNCS VENT caution light
R comes on.

R - release the LIGHT TEST pushbutton - the EXT PWR/NOT IN USE indicator
R switch. light goes off
R - the COCKPIT CALL indicator light goes
R off
R - the APU FIRE indicator light goes off
R - the ADIRU & AVNCS VENT caution light
R goes off.

R Subtask 33-14-00-710-055

R C. Do the annunciator light test for the EXT PWR panel 108VU with the APU

R -------------------------------------------------------------------------------
R ACTION RESULT
R -------------------------------------------------------------------------------

R On the panel 108VU: On the panel 108VU:


R - push the LIGHT TEST pushbutton - the EXT PWR/NOT IN USE indicator
R switch. light stays off
R - the COCKPIT CALL indicator light
R stays off
R - the APU FIRE indicator light stays
R off
R - the ADIRU & AVNCS VENT caution light
R comes on.

R - release the LIGHT TEST pushbutton - the EXT PWR/NOT IN USE indicator
R switch. light stays off



EFF :

ALL  33-14-00

Page 503
Nov 01/06
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
R - the COCKPIT CALL indicator light
R stays off
R - the APU FIRE indicator light stays
R off
R - the ADIRU & AVNCS VENT caution light
R goes off.

5. Close-up
________

Subtask 33-14-00-860-051

A. Put the aircraft back to its initial configuration.

(1) On the center pedestal 11VU and overhead panel 20VU, on all the RMPs,
set the ON/OFF switch to the OFF position.

(2) On the Captain and F/O instrument panels, the overhead panel, the
glareshield, make sure that the annunciator lights that came on
during the job set-up go off.

(3) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).
R



EFF :

ALL  33-14-00

Page 504
Nov 01/06
 
IAC 
______________________________________________________________________________
BOARD - ANNUNCIATOR LIGHT TEST AND INTERFACE (1LP,2LP,3LP,4LP,5LP,6LP,7LP,8LP,
9LP,10LP,11LP,12LP,18LP,19LP,20LP) - REMOVAL/INSTALLATION
_________________________________________________________

TASK 33-14-33-000-001

Removal of the Annunciator-Light Test and Interface-Board (1LP, 2LP, 3LP, 4LP,
5LP, 6LP, 7LP, 8LP, 9LP, 10LP, 11LP, 12LP, 18LP, 19LP, 20LP)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific access platform 1.50 m (4 ft. 11 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R **ON A/C 001-012, 014-099,

33-14-33-991-001 Fig. 401

**ON A/C ALL

R Post SB 34-1188 For A/C 001-012,014-099,

33-14-33-991-001-A Fig. 401A



EFF :

ALL  33-14-33

Page 401
May 01/06
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-14-33-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/TST/BOARD/SPLY 30LP X06

Subtask 33-14-33-010-050

B. Get Access

(1) Put the access platform in position under the access door 822.

(2) Open the access door 822.

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-14-33-991-001)

**ON A/C ALL

Post SB 34-1188 For A/C 001-012,014-099,

(Ref. Fig. 401A/TASK 33-14-33-991-001-A)



EFF :

ALL  33-14-33

Page 402
Aug 01/06
 
IAC 
Annunciator-Light Test and Interface-Board
Figure 401/TASK 33-14-33-991-001


R

EFF :

001-012, 014-099,  33-14-33

Page 403
May 01/06
 
IAC 
R Annunciator-Light Test and Interface-Board
R Figure 401A/TASK 33-14-33-991-001-A



EFF :

ALL  33-14-33

Page 404
May 01/05
 
IAC 
**ON A/C ALL

Subtask 33-14-33-020-050

A. Removal of the board

(1) Fully loosen the two screws (2) that attach the defective
annunciator-light test and interface-board (1) to its support (3).

(2) Remove the annunciator light test board (1).



EFF :

ALL  33-14-33

Page 405
May 01/06
R  
IAC 
TASK 33-14-33-400-001

Installation of the Annunciator-Light Test and Interface-Board (1LP, 2LP, 3LP,


4LP, 5LP, 6LP, 7LP, 8LP, 9LP, 10LP, 11LP, 12LP, 18LP, 19LP, 20LP)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific access platform


No specific access platform 1.5 m (4 ft. 11 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-14-00-710-001 Operational Test of the Annunciator Light Test System


in the Cockpit

R **ON A/C 001-012, 014-099,

33-14-33-991-001 Fig. 401

**ON A/C ALL

R Post SB 34-1188 For A/C 001-012,014-099,

33-14-33-991-001-A Fig. 401A



EFF :

ALL  33-14-33

Page 406
May 01/06
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-14-33-010-051

A. Get Access

(1) Make sure that the access platform is in position under the access
door 822.

(2) Make sure that the access door 822 is open.

Subtask 33-14-33-865-051

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/TST/BOARD/SPLY 30LP X06

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-14-33-991-001)

**ON A/C ALL

Post SB 34-1188 For A/C 001-012,014-099,

(Ref. Fig. 401A/TASK 33-14-33-991-001-A)



EFF :

ALL  33-14-33

Page 407
Aug 01/06
 
IAC 
**ON A/C ALL

Subtask 33-14-33-420-050

A. Installation of the board

(1) Install the new annunciator-light test and interface-board (1).

(2) Tighten the two screws (2) that attach the annunciator light test and
interface-board to its support (3).

Subtask 33-14-33-865-052

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
30LP

Subtask 33-14-33-710-050

C. Do the operational test: (Ref. TASK 33-14-00-710-001).

5. Close-up
________

Subtask 33-14-33-410-050

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Close the access door 822.

(3) Remove the access platform.



EFF :

ALL  33-14-33

Page 408
May 01/06
 
IAC 
__________________________________________________________
TRANSFORMER - ANNUNCIATOR LIGHT TEST (31LP,35LP,36LP,37LP)
____________________
REMOVAL/INSTALLATION

TASK 33-14-51-000-001

Removal of the Essential Transformers (31LP, 35LP)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking cap


No specific circuit breaker(s) safety clip(s)
No specific ALLEN wrench

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-14-51-991-001 Fig. 401



EFF :

ALL  33-14-51

Page 401
May 01/06
R  
IAC 
3. __________
Job Set-up

Subtask 33-14-51-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/TST/BOARD/SPLY 30LP X06
R
FOR 31LP
R
49VU LIGHTING/XFMR/115V.5V/ESS BUS 29LP H03
R
FOR 35LP
R
122VU LIGHTING/ANN LT SPLY/XFMR/STAT INV 28LP X03

Subtask 33-14-51-010-050

B. Get Access

(1) Remove the ceiling panel 211HC with an ALLEN wrench.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-14-51-991-001)

Subtask 33-14-51-020-050

A. Removal of the Essential Transformer

(1) Disconnect the movable connector (4) from the defective transformer
(1). Put a blanking cap on the disconnected connector.

(2) Loosen the four screws (3) and the washers (2) that attach the
defective transformer (1) to the structure.

(3) Remove the defective transformer (1).



EFF :

ALL  33-14-51

Page 402
Aug 01/06
 
IAC 
Essential Transformer
Figure 401/TASK 33-14-51-991-001



EFF :

ALL  33-14-51

Page 403
Aug 01/06
R  
IAC 
TASK 33-14-51-000-002

Removal of the System 1 (2) Transformer (37LP, 36LP)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking cap


No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-14-51-991-002 Fig. 402

3. __________
Job Set-up

Subtask 33-14-51-865-052

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/TST/BOARD/SPLY 30LP X06
R
FOR 36LP
R
122VU LIGHTING/ANN LT SPLY/XFMR/BUS 2 27LP X05
R
FOR 37LP
R
122VU LIGHTING/ANN LT SPLY/XFMR/BUS 1 26LP X04



EFF :

ALL  33-14-51

Page 404
Aug 01/06
 
IAC 
R

Subtask 33-14-51-010-051

B. Get Access

(1) In the cockpit, remove the panels 121VU and/or 122VU which give
access to the panel 120VU.

(2) Loosen the quick-disconnect fasteners of these panels:


FOR 37LP
122VU
FOR 36LP
122VU, 121VU

(3) Pull these panels to the front.

4. Procedure
_________

(Ref. Fig. 402/TASK 33-14-51-991-002)

Subtask 33-14-51-020-051

A. Removal of the Transformer

(1) Disconnect the movable connector (4) of the defective transformer


(1). Put a blanking cap on the disconnected connector.

(2) Loosen the four screws (3) and the washers (2) that attach the
defective transformer (1) to the structure.

(3) Remove the transformer (1).



EFF :

ALL  33-14-51

Page 405
Aug 01/06
 
IAC 
System 1 (2) Transformer
Figure 402/TASK 33-14-51-991-002



EFF :

ALL  33-14-51

Page 406
Aug 01/06
R  
IAC 
TASK 33-14-51-400-001

Installation of the Essential Transformers (31LP, 35LP)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking cap


No specific ALLEN wrench

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-14-00-710-001 Operational Test of the Annunciator Light Test System


in the Cockpit
33-14-51-991-001 Fig. 401



EFF :

ALL  33-14-51

Page 407
Aug 01/06
R  
IAC 
3. __________
Job Set-up

Subtask 33-14-51-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/TST/BOARD/SPLY 30LP X06
R
FOR 31LP
R
49VU LIGHTING/XFMR/115V.5V/ESS BUS 29LP H03
R
FOR 35LP
R
122VU LIGHTING/ANN LT SPLY/XFMR/STAT INV 28LP X03

Subtask 33-14-51-010-052

B. Get Access

(1) Make sure that the ceiling panel 211HC is removed.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-14-51-991-001)

Subtask 33-14-51-420-050

A. Installation of the Essential Transformer

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Remove the blanking cap from the electrical connector.

(4) Make sure that the electrical connectors are clean and in the correct
condition.

(5) Install the new transformer (1).



EFF :

ALL  33-14-51

Page 408
Aug 01/06
 
IAC 
(6) Tighten the four screws (3) and the washers (2) that attach the
transformer (1) to the structure.

(7) Connect the movable connector (4) to the transformer (1).

Subtask 33-14-51-865-053

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
30LP
FOR 31LP
29LP
FOR 35LP
28LP

Subtask 33-14-51-710-050

C. Do the operational test (Ref. TASK 33-14-00-710-001).

5. Close-up
________

Subtask 33-14-51-410-051

A. Close Access

(1) Install the ceiling panel 211HC with an ALLEN wrench.

(2) Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-14-51

Page 409
Aug 01/06
R  
IAC 
TASK 33-14-51-400-002

Installation of the System 1 (2) Transformer (37LP, 36LP)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking cap

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-14-00-710-001 Operational Test of the Annunciator Light Test System


in the Cockpit
33-14-51-991-002 Fig. 402



EFF :

ALL  33-14-51

Page 410
Aug 01/06
R  
IAC 
3. __________
Job Set-up

Subtask 33-14-51-865-055

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/TST/BOARD/SPLY 30LP X06
R
FOR 36LP
R
122VU LIGHTING/ANN LT SPLY/XFMR/BUS 2 27LP X05
R
FOR 37LP
R
122VU LIGHTING/ANN LT SPLY/XFMR/BUS 1 26LP X04

Subtask 33-14-51-010-053

B. Get Access

(1) Make sure that the panel(s) 121VU and/or 122VU is (are) removed.

(2) Make sure that the quick-disconnect fasteners are loosened for these
panels:
FOR 37LP
112VU
FOR 36LP
122VU, 121VU

(3) Make sure that these panels are pulled to the front.



EFF :

ALL  33-14-51

Page 411
Aug 01/06
 
IAC 
4. Procedure
_________

(Ref. Fig. 402/TASK 33-14-51-991-002)

Subtask 33-14-51-420-051

A. Installation of the Transformer

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Remove the blanking cap from the electrical connector.

(4) Make sure that the electrical connectors are clean and in the correct
condition.

(5) Install the new transformer (1).

(6) Install the four screws (3) and the washers (2) that attach the
transformer (1) to the structure.

(7) Connect the movable connector (4) to the transformer.

Subtask 33-14-51-410-050

B. Install these panels. Attach them with the quick-disconnect fasteners:


FOR 37LP
122VU
FOR 36LP
122VU, 121VU

Subtask 33-14-51-865-054

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
30LP
FOR 36LP
27LP
FOR 37LP
26LP

Subtask 33-14-51-710-051

D. Do the operational test (Ref. TASK 33-14-00-710-001).



EFF :

ALL  33-14-51

Page 412
Aug 01/06
R  
IAC 
5. Close-up
________

Subtask 33-14-51-942-051

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-14-51

Page 413
Aug 01/06
R  
IAC 
CABIN - DESCRIPTION AND OPERATION
_________________________________

1. General
_______
R
R The cabin lighting system illuminates the cabin, the entrances, the
R lavatories, the galley and the attendant work areas.
R The system has these sub-systems:
R
R - General Illumination (Ref. 33-21-00)
R - Call System (Ref. 33-23-00)
R - Lavatory Lighting (Ref. 33-24-00)
R - Passenger Reading Lights (Ref. 33-25-00)
R - Lavatory Lighted Signs (Ref. 33-26-00)
R - Cabin Attendant Work-Lights (Ref. 33-27-00).
R

R NOTE : The Call System and the lighted signs NO SMOKING, FASTEN SEAT BELT
____
R and RETURN TO SEAT (NS/FSB/RTS) are part of the Cabin
R Intercommunication Data System (CIDS) (Ref. 23-73-00).

2. Description
___________

A. General Illumination
(Ref. Fig. 001)
(Ref. 33-21-00)
The general illumination system has fluorescent tubes which are installed
in the ceiling panels along the center aisle (CEILING lights), above the
windows (WINDOW lights) and at each entrance.
They illuminate the cabin and the entrance areas.
The cabin attendants control the general illumination through the Forward
Attendant Panel (FAP) and the Additional Attendant Panel(s) (AAP), which
are part of the Cabin Intercommunication Data System (CIDS) (Ref.
23-73-00).

NOTE : The installation of the Additional Attendant Panel(s) (AAP) is a


____
customer option.

B. Lavatory Lighting
(Ref. Fig. 002)
(Ref. 33-24-00)
The lavatory lighting system gives illumination inside the lavatories.
Each lavatory has a fluorescent tube and additional halogen light(s).
A microswitch in the lavatory door frame controls the brightness level of
the fluorescent tube and the halogen light(s).
The cabin attendants control the power of the lavatory lighting system
through a membrane switch (POWER LAV) on the Forward Attendant Panel
(FAP).



EFF :

ALL  33-20-00

Page 1
Nov 01/07
 
IAC 
R General Illumination - Schematic
R Figure 001



EFF :

ALL  33-20-00

Page 2
May 01/00
 
IAC 
Lavatory Lighting - Schematic (Example)
Figure 002



EFF :

ALL  33-20-00

Page 3
Nov 01/04
R  
IAC 
NOTE : The installation of the additional halogen light(s) is a customer
____
option.

C. Passenger Reading Lights


(Ref. 33-25-00)
The passenger reading lights are high intensity lights, which give
additional illumination to the passengers.
Each passenger controls his own reading light through a pushbutton.
The cabin attendants control the power of the reading light system
through a membrane switch (POWER READ) on the Forward Attendant Panel
(FAP).

D. Lavatory Lighted Signs


(Ref. Fig. 002)
(Ref. 33-26-00)
The lavatory lighted signs indicate if the lavatories are occupied or
not.
A microswitch in the lavatory door frame controls the power of the
lavatory lighted signs.

E. Cabin Attendant Work-Lights


(Ref. 33-27-00)
The cabin attendant work-lights are high intensity lights, which give
additional illumination to the attendants and their working areas.
Each attendant controls his own work-light through a pushbutton.
The cabin attendants control the power of the work-light system through a
membrane switch (POWER ATTN) on the Forward Attendant Panel (FAP).

NOTE : The installation of the cabin attendant work-lights is a customer


____
option.



EFF :

ALL  33-20-00

Page 4
Nov 01/04
R  
IAC 
R CABIN - DEACTIVATION/REACTIVATION
_________________________________

TASK 33-20-00-040-001

Deactivation of the Cabin NO SMOKING / FASTEN SEAT BELTS / RETURN TO SEAT


(NS/FSB/RTS) Signs

1. __________________
Reason for the Job

R Refer to the MMEL TASK: 33-20-02 b)


R Cabin - Cabin Signs (No Smoking/
R Fasten Seat Belt/Return to Seat)

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific warning notices

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

23-73-00-710-017 Operational Test of the Cabin Signs


24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-20-00-861-051

A. Energize the aircraft electrical circuits


(Ref. TASK 24-41-00-861-002).



EFF :

ALL  33-20-00

Page 401
Nov 01/05
 
IAC 
4. Procedure
_________

Subtask 33-20-00-040-051

A. Deactivation of the Cabin NS/FSB/RTS Signs

(1) Do the operational test of the cabin signs (Ref. TASK 23-73-00-710-
017) and find the defective NS/FSB/RTS sign(s).

(2) Find the passenger seats from which you cannot see the serviceable
NS/FSB/RTS sign.

(3) Put warning notices in position on these seats to tell the passengers
not to use them.

NOTE : It must be possible to see a serviceable NS/FSB/RTS sign from


____
every passenger seat that is in use.

(4) Make an entry in the aircraft technical logbook.

5. Close-up
________

Subtask 33-20-00-860-051

A. Aircraft Maintenance Configuration

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) De-energize the aircraft electrical circuits


(Ref. TASK 24-41-00-862-002).



EFF :

ALL  33-20-00

Page 402
May 01/05
 
IAC 
TASK 33-20-00-440-001

Reactivation of the Cabin NO SMOKING / FASTEN SEAT BELTS / RETURN TO SEAT


(NS/FSB/RTS) Signs

1. __________________
Reason for the Job

R Refer to the MMEL TASK: 33-20-02 b)


R Cabin - Cabin Signs (No Smoking/
R Fasten Seat Belt/Return to Seat)

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific warning notices

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
TSM 23 (for corrective action)

3. __________
Job Set-up

Subtask 33-20-00-861-052

A. Energize the aircraft electrical circuits


(Ref. TASK 24-41-00-861-002)



EFF :

ALL  33-20-00

Page 403
Nov 01/05
 
IAC 
4. Procedure
_________

Subtask 33-20-00-440-050

A. Reactivation of the Cabin NS/FSB/RTS Signs

(1) Remove the warning notices from the applicable passenger seats.

(2) Do the trouble shooting of the cabin NS/FSB/RTS signs (Ref. TSM 23)
and make the applicable correction.

(3) Make a record of the reactivation in the aircraft technical logbook.

5. Close-up
________

Subtask 33-20-00-860-052

A. Aircraft Maintenance Configuration

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) De-energize the aircraft electrical circuits


(Ref. TASK 24-41-00-862-002)



EFF :

ALL  33-20-00

Page 404
May 01/05
 
IAC 
GENERAL ILLUMINATION - DESCRIPTION AND OPERATION
________________________________________________

1. General
_______

**ON A/C 001-012, 014-099,

Fluorescent lamps illuminate the passenger cabin and the entrance areas as
listed below:

A. Passenger Cabin Lighting


(Ref. Fig. 001, 002, 003)
R The passenger cabin is divided into different zones given by the customer
R seat layout.
R Four strips of fluorescent lamps give light to the passenger cabin zones.
R Each strip has many fluorescent lamps. The four strips in each cabin zone
R are divided into two pairs for control purposes. These are the inboard
R pair, CEILING lights, and the outboard pair, WINDOW lights. The two pairs
R of strips in each cabin zone can be set to three different brightness
R levels. These are:
R - full brightness (BRT)
R - half brightness (DIM 1)
R - 10 % of full brightness (DIM 2).
R

B. Entrance Area Lighting


(Ref. Fig. 003)
Fluorescent lamps installed in ceiling panels illuminate the entrance
areas.
This lighting is controlled separately from the cabin lighting. These can
be selected to three different brightness levels in exactly the same way
as the cabin lights. The brightness levels are, full brightness (BRT),
half brightness (DIM 1) and 10 % of full brightness (DIM 2).

**ON A/C 101-199, 901-999,

Fluorescent lamps give lighting to the passenger cabin and the entrance
areas.

A. Passenger Cabin Lighting

**ON A/C 101-199,

(Ref. Fig. 001A)



EFF :

ALL  33-21-00

Page 1
Feb 01/08
 
IAC 
**ON A/C 901-999,

(Ref. Fig. 001B)

**ON A/C 101-199,

(Ref. Fig. 002A)

**ON A/C 901-999,

(Ref. Fig. 002B)

**ON A/C 101-199, 901-999,

(Ref. Fig. 003A)


These lighting systems are controlled through the Cabin
Intercommunication Data-System (CIDS):
- the cabin lighting
- the entrance lighting.
The control buttons are installed on the Flight Attendant Panel (FAP) and
R on the Additional Attendant Panel (AAP). Each system is controlled
R independently by its related buttons.
Four lighting strips of fluorescent lamps give lighting to the passenger
cabin zones. Each lighting strip has many fluorescent lamps. The four
lighting strips in each cabin zone are divided into two pairs for control
R purposes. These are the inboard pair, CEILING lights, and the outboard
R pair, WINDOW lights. The two pairs of lighting strips in each cabin zone
R can be set to three different brightness levels. These are:
- full brightness (BRT)
- half brightness (DIM1)
- 10% of full brightness (DIM2).

B. Entrance Area Lighting


(Ref. Fig. 003A)
Fluorescent lamps installed in the ceiling panels give lighting to the
entrance areas.
This lighting is controlled independently from the cabin lighting. These
fluorescent lamps can also be set to three different brightness levels,
which are:
- full brightness (BRT)
- half brightness (DIM1)
- 10% of full brightness (DIM2).



EFF :

101-199, 901-999,  33-21-00

Page 2
Feb 01/08
 
IAC 
Ceiling and Window Lights (Right-Hand) - Schematic
Figure 001


R

EFF :

001-012, 014-099,  33-21-00

Page 3/4
Aug 01/07
 
IAC 
INTENTIONALLY BLANK


R



 33-21-00

Page 5
Nov 01/06
 
IAC 
R Ceiling and Window Lights (Right-Hand) - Schematic
Figure 001A (SHEET 1)



EFF :

101-199,  33-21-00

Page 6
Feb 01/08
 
IAC 
R Ceiling and Window Lights (Right-Hand) - Schematic
Figure 001A (SHEET 2)



EFF :

101-199,  33-21-00

Page 7
Feb 01/08
 
IAC 
R Ceiling and Window Lights (Right-Hand) - Schematic
Figure 001B (SHEET 1)



EFF :

901-999,  33-21-00

Page 8
Feb 01/08
 
IAC 
R Ceiling and Window Lights (Right-Hand) - Schematic
Figure 001B (SHEET 2)



EFF :

901-999,  33-21-00

Page 9
Feb 01/08
 
IAC 
INTENTIONALLY BLANK





 33-21-00

Page 10
May 01/07
R  
IAC 
Ceiling and Window Lights (Left-Hand) - Schematic
Figure 002


R

EFF :

001-012, 014-099,  33-21-00

Page 11/12
Aug 01/07
 
IAC 
INTENTIONALLY BLANK


R



 33-21-00

Page 13
May 01/07
 
IAC 
R Ceiling and Window Lights (Left-Hand) - Schematic
R Figure 002A (SHEET 1)


R

EFF :

101-199,  33-21-00

Page 14
May 01/07
 
IAC 
R Ceiling and Window Lights (Left-Hand) - Schematic
R Figure 002A (SHEET 2)



EFF :

101-199,  33-21-00

Page 15
May 01/07
 
IAC 
R Ceiling and Window Lights (Left-Hand) - Schematic
Figure 002B (SHEET 1)



EFF :

901-999,  33-21-00

Page 16
Feb 01/08
 
IAC 
R Ceiling and Window Lights (Left-Hand) - Schematic
Figure 002B (SHEET 2)



EFF :

901-999,  33-21-00

Page 17
Feb 01/08
 
IAC 
Entrance Lighting - Schematic
Figure 003


R

EFF :

001-012, 014-099,  33-21-00

Page 18
May 01/07
 
IAC 
R Entrance Lighting - Schematic
Figure 003A



EFF :

101-199, 901-999,  33-21-00

Page 19
May 01/08
 
IAC 
When the cockpit door is opened and the engines are in operation, the
lighting of the forward entrance LH is dimmed automatically to 10% of
full brightness (DIM2).
If a full failure of the FAP and/or the CIDS occurs, the lighting of the
forward entrance comes on automatically to 100% intensity level. A cabin
decompression also occurs and the pre-set mode is then cancelled.

**ON A/C ALL

2. __________________
Component Location

**ON A/C 001-012, 014-099,

(Ref. Fig. 004)

-------------------------------------------------------------------------------
FIN FUNCTIONAL DESIGNATION PANEL ZONE ACCESS ATA
DOOR REF.
-------------------------------------------------------------------------------
1LG1 LAMP AND BALLAST UNIT (RIGHT-HAND) 200 33-21-11
THRU WINDOW
1LG10
2LG1 LAMP AND BALLAST UNIT (RIGHT-HAND) 200 33-21-11
THRU WINDOW
2LG10
3LG1 LAMP AND BALLAST UNIT (LEFT-HAND) 200 33-21-11
THRU CEILING
3LG10
4LG1 LAMP AND BALLAST UNIT (RIGHT-HAND) 200 33-21-11
THRU CEILING
4LG10
11LG1 LAMP AND BALLAST UNIT (LEFT-HAND) 200 33-21-11
THRU WINDOW
11LG10
12LG1 LAMP AND BALLAST UNIT (RIGHT-HAND) 200 33-21-11
THRU WINDOW
12LG10
13LG1 LAMP AND BALLAST UNIT (LEFT-HAND) 200 33-21-11
THRU CEILING
13LG10
14LG1 LAMP AND BALLAST UNIT (RIGHT-HAND) 200 33-21-11
THRU CEILING
14LG10
20LG LAMP AND BALLAST UNIT 1 (RIGHT-HAND) 200 33-21-11
ENTRANCE



EFF :

ALL  33-21-00

Page 20
Feb 01/08
R  
IAC 
-------------------------------------------------------------------------------
FIN FUNCTIONAL DESIGNATION PANEL ZONE ACCESS ATA
DOOR REF.
-------------------------------------------------------------------------------
21LG LAMP AND BALLAST UNIT 1 (LEFT-HAND) 200 33-21-11
ENTRANCE
23LG LAMP AND BALLAST UNIT 2 (LEFT-HAND) 200 33-21-11
ENTRANCE
24LG LAMP AND BALLAST UNIT 2 (RIGHT-HAND) 200 33-21-11
ENTRANCE
30LG LAMP AND BALLAST UNIT (RIGHT-HAND) 200 33-21-11
WINDOW
31LG LAMP AND BALLAST UNIT (LEFT-HAND) 200 33-21-11
CEILING
34LG LAMP AND BALLAST UNIT (RIGHT-HAND) 200 33-21-11
Window
37LG LAMP AND BALLAST UNIT (LEFT-HAND) 200 33-21-11
WINDOW
38LG LAMP AND BALLAST UNIT (RIGHT-HAND) 200 33-21-11
CEILING
120RH PANEL - FORWARD ATTENDANT 221 23-73-12
126RH PANEL - AFT ATTENDANT 261 23-73-13

**ON A/C 101-199, 901-999,

(Ref. Fig. 005)

**ON A/C 101-199,

(Ref. Fig. 006)

**ON A/C 901-999,

(Ref. Fig. 006A)

**ON A/C 101-199, 901-999,

-------------------------------------------------------------------------------
FIN FUNCTIONAL DESIGNATION PANEL ZONE ACCESS ATA
DOOR REF.
-------------------------------------------------------------------------------
BALLAST UNITS WITH FLUORESCENT LAMPS 200 33-21-11



EFF :

ALL  33-21-00

Page 21
Feb 01/08
R  
IAC 
General Illumination - Component Location
Figure 004 (SHEET 1)


R

EFF :

001-012, 014-099,  33-21-00

Page 22
Aug 01/07
 
IAC 
General Illumination - Component Location
Figure 004 (SHEET 2)


R

EFF :

001-012, 014-099,  33-21-00

Page 23
Aug 01/07
 
IAC 
General Illumination - Component Location
Figure 004 (SHEET 3)


R

EFF :

001-012, 014-099,  33-21-00

Page 24
Aug 01/07
 
IAC 
General Illumination - Component Location
Figure 004 (SHEET 4)


R

EFF :

001-012, 014-099,  33-21-00

Page 25
Aug 01/07
 
IAC 
Attendant Panels - Component Location
Figure 005


R

EFF :

101-199, 901-999,  33-21-00

Page 26
Aug 01/07
 
IAC 
Ceiling & Window Lighting Strips
Figure 006


R

EFF :

101-199,  33-21-00

Page 27
Aug 01/07
 
IAC 
R Ceiling and Window Lighting Strips
Figure 006A



EFF :

901-999,  33-21-00

Page 28
Feb 01/08
 
IAC 
**ON A/C ALL

3. __________________
System Description

**ON A/C 001-012, 014-099,

A. Cabin Illumination
The cabin lamps are distributed in four strips throughout the cabin.
The four strips are divided into two pairs for control purposes. The two
outboard strips are designated as WINDOW (WDO) lights and the two center
strips as CEILING (CLG) lights. The system is designed so that the window
and ceiling lights can be on together or separately. When on, the
fluorescent lamps can be selected to 100 % (BRT), 50 % (DIM 1) or 10 %
(DIM 2) intensity. Each fluorescent lamp is installed in a holder which
contains an integral ballast unit. The units are supplied with 115VAC
from busbars 212XP and 214XP through circuit breakers 300LG thru 307LG
(cabin lighting) and 308LG (entrance lighting). The lighting system is
controlled from the forward attendant panel 120RH, which contains the
following membrane switches:

R B. Forward Attendant Panel (FAP)

(1) MAIN ON - when pushed, switches on the cabin zones and entrance areas
lighting with 100 % intensity. It also causes the integral light in
all BRT, WDO and CLG membrane switches to come on.

(2) MAIN OFF - when pushed, the cabin zones and entrance area lights goes
off. Also any light of the general illumination switch goes off.
This function is disabled in flight.

(3) ENTRY BRT - when initially pushed, causes the related entrance area
lighting to come on with 100 % intensity. It also causes the integral
light under the membrane switch foil to come on. The lights may be
switched off by pushing the membrane switch twice in succession.

(4) ENTRY DIM1 - when initially pushed, causes the related entrance area
lighting to come on with 50 % intensity. It also causes the integral
light under the membrane switch foil to come on. The lights may be
switched off by pushing the membrane switch twice in succession.

(5) ENTRY DIM2 - when initially pushed, causes the related entrance area
lighting to come on with 10 % intensity. It also causes the integral
light under the membrane switch foil to come on. The lights may be
switched off by pushing the membrane switch twice in succession.



EFF :

ALL  33-21-00

Page 29
Feb 01/08
 
IAC 
(6) BRT - when initially pushed, causes the related cabin zone lighting
to come on with 100 % intensity. It also causes the integral lights
in the related BRT, cabin WDO and cabin CLG membrane switch to come
on. The lights may be switched off by pushing the membrane switch
twice in succession.

(7) DIM1 - when initially pushed, causes the related cabin zone lighting
to come on with 50 % intensity. It also causes the integral light in
the related DIM 1, cabin WDO and cabin CLG membrane switch to come
on. The lights may be switched off by pushing the membrane switch
twice in succession.

(8) DIM2 - when initially pushed, causes the related cabin zone lighting
to come on with 10 % intensity. It also causes the integral light in
the related DIM 2, cabin WDO and cabin CLG membrane switch to come
on. The lights may be switched off by pushing the membrane switch
twice in succession.

(9) WDO - With the cabin lighting set on at any intensity. On pushing
this membrane switch, the window lights in each cabin zone and the
light under the membrane switch foil go off. Pushing the membrane
switch again will cause the lights to come on.

(10) CLG - With the cabin lighting set on at any intensity. On pushing
this membrane switch, the ceiling lights in each cabin zone and the
light under the membrane switch foil go off. Pushing the membrane
switch again will cause the lights to come on.

**ON A/C 101-199, 901-999,

A. Cabin Illumination
The cabin lamps are divided in four lighting strips throughout the cabin
zones. The four lighting strips in each cabin zone are divided into two
pairs for control purposes. The two outboard strips are designated as
WINDOW (WDO) lights and the two center strips as CEILING (AISLE) lights.
The system is designed so that the window and ceiling lights in the cabin
zone can be on together or separately. When on, the fluorescent lamps can
be set to 100% (BRT), 50% (DIM1) or 10% (DIM2) intensity. Each
fluorescent lamp is installed in a holder which contains an ballast unit.
The units are supplied with 115VAC from busbars 212XP and 214XP through
circuit breakers 300LG thru 307LG (cabin lighting) and 308LG (entrance
lighting). The lighting system is controlled from the FAP 120RH and the
AAP 126RH.



EFF :

ALL  33-21-00

Page 30
Feb 01/08
R  
IAC 
B. Flight Attendant Panel (FAP) 120RH

(1) When the button MAIN ON is pushed, all fluorescent lamps come on
with 100% intensity. Also the button indicator light comes on.

(2) When the button MAIN OFF is pushed, all fluorescent lamps go off.
Also the button indicator light goes off.
In flight this function is not available.

(3) When the button ENTRY BRT is pushed initially, the related entrance
area lighting comes on with 100% intensity. Also the button indicator
light comes on.

(4) When the button ENTRY DIM1 is pushed initially, the related
entrance area lighting comes on with 50% intensity. Also the button
indicator light comes on.

(5) When the button ENTRY DIM2 is pushed initially, the related
entrance area lighting comes on with 10% intensity. Also the button
indicator light comes on.

(6) When the button BRT is pushed initially, the related cabin zone
lighting comes on with 100% intensity. Also the button indicator
light comes on.

(7) When the button DIM1 is pushed initially, the related cabin zone
lighting comes on with 50% intensity. Also the button indicator light
comes on.

(8) When the button DIM2 is pushed initially, the related cabin zone
lighting comes on with 10% intensity. Also the button indicator light
comes on.

(9) When the button WDO is pushed, all window lights in each cabin zone
come on. Also the button indicator light comes on. When the button
WDO is pushed again, all window lights in each cabin zone go off.
The button indicator light also goes off.

(10) When the button AISLE is pushed, all ceiling lights in each cabin
zone come on. Also the button indicator light comes on. When the
button AISLE is pushed again, all ceiling lights in each cabin zone
go off. The button indicator light also goes off.



EFF :

101-199, 901-999,  33-21-00

Page 31
Feb 01/08
R  
IAC 
C. Additional Attendant Panel (AAP)

NOTE : The AAP has no buttons MAIN ON and MAIN OFF.
____

(1) When the button ENTRY BRT is pushed initially, the related entrance
area lighting comes on with 100% intensity. Also the button indicator
light comes on.

(2) When the button ENTRY DIM1 is pushed initially, the related
entrance area lighting comes on with 50% intensity. Also the button
indicator light comes on.

(3) When the button ENTRY DIM2 is pushed initially, the related
entrance area lighting comes on with 10% intensity. Also the button
indicator light comes on.

(4) When the button CABIN BRT is pushed initially, the related cabin
zone lighting comes on with 100% intensity. Also the button indicator
light comes on.

(5) When the button CABIN DIM1 is pushed initially, the related cabin
zone lighting comes on with 50% intensity. Also the button indicator
light comes on.

(6) When the button CABIN DIM2 is pushed initially, the related cabin
zone lighting comes on with 10% intensity. Also the button indicator
light comes on.

**ON A/C ALL

4. _____________________
Component Description

**ON A/C 001-012, 014-099,

A. Lamp and Ballast Unit


(Ref. Fig. 007)
The ballast unit provides power for one fluorescent lamp. Each unit
supplies low-voltage power for filament heating and high-voltage power
for lamp ignition. The unit contains a transformer, control electronics
and two relays. When no input signals are received by the control
electronic, the lamp lights with 100 % intensity (BRT). When a 28VDC
signal is applied to pin D, the lamp lights with 50 % intensity. With a
28VDC signal at pin E, the lamp lights with 10 % intensity. When 28VDC is
at pin F, the internal control relay is energized and the 115VAC for the
transformer is disconnected. The fluorescent lamp goes off.



EFF :

ALL  33-21-00

Page 32
Feb 01/08
R  
IAC 
Fluorescent Lamp with Ballast Unit - Schematic
Figure 007


R

EFF :

001-012, 014-099,  33-21-00

Page 33
Feb 01/08
 
IAC 
**ON A/C 101-199, 901-999,

A. Fluorescent Lamp, Advanced Integrated Ballast-Units (AIBUs) and Stand


Alone - Passenger Interface and Supply Adapter (StA-PISA)
R (Ref. Fig. 007A)
The AIBUs give power for the fluorescent lamp(s). The AIBUs supply the
lamps with low voltage power for the filament heating and the high
voltage power for the lamp ignition. The AIBU has two Printed Circuit
Boards (PCBs). The power supply PCB contains the complete power supply
and the control module. The amplifier PCB contains the complete power
electronics and the choke.
When the cabin and entrance lighting is set to on:
- The Decoder/Encoder Unit (DEU) A gives no in-put signals to the AIBU.
- The fluorescent lamp is on with 100% intensity level.
The AIBUs are made to give a continuous dimming from 100% to 5% light
intensity level.

B. Stand Alone - Passenger Interface and Supply Adapter (StA-PISA)


The StA-PISA gives the digital interface between the CIDS (DEU A) and the
specified cabin light devices, which are used for the pre-programmed
lighting scenarios. The StA-PISA is a modular unit with PC-Boards.

**ON A/C ALL

5. ________________________________
Operation/Control and Indication

**ON A/C 001-012, 014-099,

The forward attendant panel 120RH is connected to the Directors 101RH and
102RH of the Cabin Intercommunication Data System (CIDS).
The input signals from the forward attendant panel 120RH are processed by
the director and transmitted to the Decoder/Encoder Units (DEUs). The DEUs
accept the input data and activate the output to the fluorescent lamps with
ballast units in accordance with the code presented at the input. The DEU is
capable of handling up to four fluorescent lamps with ballast units. Three
signal lines connect each fluorescsent lamp with ballast unit to the related
DEU.
The truth table below shows the state of the fluorescent lamps when
activated by the DEU output signal. The DEU output signal has two levels 0
(0VDC) and 1 (28VDC).
As can be seen in the truth table with no output signal from the associated
DEU the fluorescent lamps will illuminate at full brightness.

Truth Table



EFF :

ALL  33-21-00

Page 34
Feb 01/08
 
IAC 
R Fluorescent Lamp with Advanced Integrated Ballast-Unit (AIBU) - Block Diagram
R Figure 007A


R

EFF :

101-199, 901-999,  33-21-00

Page 35
Feb 01/08
 
IAC 
--------------------------------------------------------------------------
| | BALLAST UNIT INPUT PIN. |
| LAMP STATE | SIGNAL |
| |--------------------------------------------|
| | F | D | E |
|-----------------------------|---------------|---------------|------------|
| BRT | 0 | 0 | 0 |
|-----------------------------|---------------|---------------|------------|
| DIM 1 (50 %) | 0 | 1 | 0 |
|-----------------------------|---------------|---------------|------------|
| DIM 2 (10 %) | 0 | 0 | 1 |
|-----------------------------|---------------|---------------|------------|
| OFF | 1 | 0 | 0 |
--------------------------------------------------------------------------

The assignment of the fluorescent lamps with ballast units to cabin zones is
programmed into the Cabin Assignment Module (CAM). The CAM is fitted in the
programming and test panel 110RH and preprogrammed for particular lighting
requirements. Any new requirements can be programmed into the CAM.

**ON A/C 101-199, 901-999,

The FAP 120RH and the AAP 126RH are connected to the Directors 101RH and
102RH of the CIDS.
The input signals from the FAP 120RH and the AAP 126RH are processed by the
R director and transmitted to the DEUs. The DEU can control up to eight
R fluorescent lamps with ballast units. Two signal lines connect each
R fluorescent lamp with ballast unit to the related DEU. The DEUs receive the
R input data and give output through the two signal lines to the fluorescent
R lamps with ballast units.
R The control of the fluorescent lamps with ballast units to the cabin zones
R is given in the Cabin Assignment Module (CAM). The CAM is installed in the
R FAP 120RH and pre-set for the applicable lighting. All changes can be made
R in the CAM.

**ON A/C ALL

A. Entrance Lighting

**ON A/C 001-012, 014-099,

(Ref. Fig. 003)


R

EFF :

ALL  33-21-00

Page 36
Feb 01/08
 
IAC 
**ON A/C 101-199, 901-999,

(Ref. Fig. 003A)

**ON A/C ALL

The entrance lighting has fluorescent lamps with ballast units installed
in the ceiling panels at the forward and aft entrances. Two fluorescent
lamps are installed in the LH and RH ceiling panels at each entrance. The
operation is the same as the cabin lighting.

(1) The entrance lighting at entrance 1 LH is automatically dimmed to


DIM2 level (10%) whenever the cockpit door is opened with the engines
running.

(2) The CIDS directors 101RH and 102RH receive one signal from the engine
oil-pressure system and another signal from the cockpit door
microswitch.
The directors 101RH and 102RH transmit their output signal to the DEU
which controls the entrance 1 LH fluorescent lamp with ballast unit.
The DEU provides a DIM2 signal and the light dims to 10% intensity.



EFF :

ALL  33-21-00

Page 37
Feb 01/08
R  
IAC 
GENERAL ILLUMINATION - ADJUSTMENT/TEST
______________________________________

TASK 33-21-00-710-001

Operational Test of the General Illumination

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

To make sure that the cabin general lighting operates correctly.

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

21-31-34-000-001 Removal of the Cabin Pressure Controller (11HL,12HL)


21-31-34-400-001 Installation of the Cabin Pressure Controller
(11HL,12HL)
23-73-00-861-001 Energize the Cabin Intercommunication Data System
(CIDS)
23-73-00-862-001 De-energize the Cabin Intercommunication Data System
(CIDS)
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-21-00-861-050

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).



EFF :

ALL  33-21-00

Page 501
Feb 01/96
 
IAC 
Subtask 33-21-00-865-050

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-099,

49VU COM/CIDS/DEU A ESS/LINE 2 155RH G05


49VU COM/CIDS/DEU A ESS/LINE 1 154RH G04
49VU COM/CIDS/DIR 1 AND 2/ESS 150RH G02

**ON A/C ALL

49VU ENGINE/2/FADEC A/AND EIU 2 2KS2 A05


49VU ENGINE/1/FADEC A/AND EIU 1 2KS1 A04
49VU ENGINE/1 AND 2/IGN/SYS A 1JH A03
49VU COM/CIDS/DEU B/ESS 153RH G03

R **ON A/C 101-199, 901-999,

49VU COM/CIDS/DIR ESS/1 150RH G01

**ON A/C 001-012, 014-099,

121VU COM NAV/CIDS/FWD ATTND/PNL 170RH M14


121VU COM NAV/CIDS/DEU A NORM/R AFT 168RH M13
121VU COM NAV/CIDS/DEU A NORM/L AFT 167RH M12
121VU COM NAV/CIDS/DEU A NORM/R MID 166RH M11
121VU COM NAV/CIDS/DEU A NORM/L MID 165RH M10
121VU COM NAV/CIDS/DEU A NORM/R FWD 164RH M09
121VU COM NAV/CIDS/DEU A NORM/L FWD 163RH M08
121VU COM NAV/CIDS/DEU B/NORM 162RH M07
121VU COM NAV/CIDS/DIR 1 AND 2/NORM 151RH M05

**ON A/C ALL

121VU ENGINE/IGN/ENG2/SYS B 3JH2 P42


121VU ENGINE/IGN/ENG1/SYS B 3JH1 P41
121VU ENGINE/IGN/ENG2/SYS A BAT 2JH2 P40



EFF :

ALL  33-21-00

Page 502
Feb 01/07
 
IAC 
-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
121VU ENGINE/IGN/ENG1/SYS A BAT 2JH1 P39
121VU ENGINE/ENG2/FADEC B 4KS2 Q40
121VU ENGINE/ENG1/FADEC B/AND EIU 1 4KS1 R41

**ON A/C 101-199,

121VU COM NAV/CIDS/DEU A NORM/R FWD 164RH M11


121VU COM NAV/CIDS/DEU A NORM/L FWD 163RH M10
121VU COM NAV/CIDS/DIR NORM/1 151RH M06
121VU COM NAV/CIDS/FWD ATTND/PNL 170RH Q14

**ON A/C 901-999,

121VU COM NAV/CIDS/DEU A NORM/R AFT 168RH M12


121VU COM NAV/CIDS/DEU A NORM/L AFT 167RH M11
121VU COM NAV/CIDS/DEU A NORM/R FWD 164RH M10
121VU COM NAV/CIDS/DEU A NORM/L FWD 163RH M09
121VU COM NAV/CIDS/DEU B/NORM 162RH M08
121VU COM NAV/CIDS/DIR NORM/1 151RH M05
121VU COM/FAP1/NORM 170RH Q14

R **ON A/C 001-012, 014-099,

R 2000VU LIGHT-CABIN-ENTRY 308LG J04

R **ON A/C ALL

R 2000VU CAB LIGHT PWR-CEILING-AFT 307LG H08


R 2000VU CAB LIGHT PWR-CEILING-AFT 304LG H07
R 2000VU CAB LIGHT PWR-CEILING-FWD 306LG H06
R 2000VU CAB LIGHT PWR-CEILING-FWD 305LG H05
R 2000VU CAB LIGHT PWR-WINDOW-AFT 302LG H04
R 2000VU CAB LIGHT PWR-WINDOW-AFT 301LG H03
R 2000VU CAB LIGHT PWR-WINDOW-FWD 303LG H02
R 2000VU CAB LIGHT PWR-WINDOW-FWD 300LG H01

R **ON A/C 101-199, 901-999,

2000VU LIGHT-CABIN-ENTRY 308LG J02



EFF :

ALL  33-21-00

Page 503
May 01/07
 
IAC 
**ON A/C ALL

Subtask 33-21-00-860-050

C. Preparation for the Test.

R (1) Energize the Cabin Intercommunication Data-System (CIDS) (Ref. TASK


23-73-00-861-001).

R (2) Make sure that the cockpit door is closed and the engines do not
R operate.

(3) Push the MAIN OFF membrane switch on the FAP 120RH to make sure that
all the entrance and cabin lights are off.

4. Procedure
_________

**ON A/C 001-012, 014-099,

Subtask 33-21-00-710-050

A. Test of all the Cabin Lighting from the Forward Attendant Panel (FAP).

(1) Do this Test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the Forward Attendant Panel At the forward and aft entrance and in
120RH: the cabin.
- push the MAIN ON membrane - all the entrance and cabin lights
switch. come on.
- push the MAIN OFF membrane - all the entrance and cabin lights go
switch. off.



EFF :

ALL  33-21-00

Page 504
Feb 01/08
 
IAC 
R **ON A/C 101-199, 901-999,

Subtask 33-21-00-710-050-A

A. Test of all the Cabin Lighting from the Flight Attendant Panel (FAP)

R (1) Do this test:

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the Flight Attendant Panel In the forward and aft entry area and
(FAP) 120RH: in the cabin:

- Push the LIGHT MAIN ON/OFF - All the entry and cabin lights come
key. on.

- Push the LIGHT MAIN ON/OFF - All the entry and cabin lights go
key again. off.

R **ON A/C 001-012, 014-099,

R Subtask 33-21-00-710-051

R B. Test of the forward and aft Entrance Lighting from the Forward Attendant
R Panel (FAP).

R (1) Do this Test.

R -------------------------------------------------------------------------------
R ACTION RESULT
R -------------------------------------------------------------------------------

R 1. On the Forward Attendant Panel At the forward and aft entrance:


R (FAP) 120RH:

R - push the ENTRY BRT membrane - the forward and aft entrance lights
R switch. come on.

R On the FAP 120RH:


R - the ENTRY BRT internal light on the
R membrane switch comes on.

R At the forward and aft entrance:


R

EFF :

ALL  33-21-00

Page 505
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
R - push the ENTRY DIM1 membrane - the forward and aft entrance lights
R switch. become dim.

R On the FAP 120RH:


R - the ENTRY BRT internal light on the
R membrane switch goes off.
R - the ENTRY DIM1 internal light on the
R membrane switch comes on.

R At the forward and aft entrance:

R - push the ENTRY DIM2 membrane - the forward and aft entrance lights
R switch. dim again.

R On the FAP 120RH:


R - the ENTRY DIM1 internal light on the
R membrane switch goes off.
R - the ENTRY DIM2 internal light on the
R membrane switch comes on.

R At the forward and aft entrance:

R - push the ENTRY BRT membrane - the forward and aft entrance lights
R switch. become bright.

R On the FAP 120RH:


R - the ENTRY DIM2 internal light on the
R membrane switch goes off.
R - the ENTRY BRT internal light on the
R membrane switch comes on.

R At the forward and aft entrance:

R - push the ENTRY BRT membrane - the forward and aft entrance lights
R switch. go off.

R On the FAP 120RH:


R - the ENTRY BRT internal light on the
R membrane switch goes off.


R

EFF :

001-012, 014-099,  33-21-00

Page 506
Nov 01/07
 
IAC 
**ON A/C 101-199, 901-901,

Subtask 33-21-00-710-051-A

B. Test of the Forward and Aft Entrance Lighting from the Flight Attendant
Panel (FAP) 120RH

R (1) Do this test:

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the FAP 120RH: On the FAP 120RH:

- Set the LIGHT page. - All possible cabin lighting zones are
shown.

- Push the ENTRY FWD/BRT key. - The ENTRY FWD/BRT indication comes
on.

In the cabin:
- The fluorescent tubes in the forward
entry area come on with 100%
intensity.

On the FAP 120RH:

- Push the ENTRY FWD/DIM1 key. - The ENTRY FWD/BRT indication goes
off.
- The ENTRY FWD/DIM1 indication comes
on.

In the cabin:
- The fluorescent tubes in the forward
entry area come on with 50%
intensity.

On the FAP 120RH:

- Push the ENTRY FWD/DIM2 key. - The ENTRY FWD/DIM1 indication goes
off.
- The ENTRY FWD/DIM2 indication comes
on.

In the cabin:



EFF :

101-199, 901-901,  33-21-00

Page 507
Feb 01/08
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- The fluorescent tubes in the forward
entry area come on with 10%
intensity.

On the FAP 120RH:

- Push the ENTRY FWD/DIM2 key - The ENTRY FWD/DIM2 indication goes
again. off.

In the cabin:
- The fluorescent tubes in the forward
entry area go off.

On the FAP 120RH:

- Push the ENTRY FWD/BRT key. - The ENTRY FWD/BRT indication comes
on.

In the cabin:
- The fluorescent tubes in the forward
entry area come on with 100%
intensity.

On the FAP 120RH:

- Push the ENTRY AFT/BRT key. - The ENTRY AFT/BRT indication comes
on.

In the cabin:
- The fluorescent tubes in the aft
entry area come on with 100%
intensity.

On the FAP 120RH:

- Push the ENTRY AFT/DIM1 key. - The ENTRY AFT/BRT indication goes
off.
- The ENTRY AFT/DIM1 indication comes
on.

In the cabin:
- The fluorescent tubes in the aft
entry area come on with 50%
intensity.


R

EFF :

101-199, 901-901,  33-21-00

Page 508
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
On the FAP 120RH:

- Push the ENTRY AFT/DIM2 key. - The ENTRY AFT/DIM1 indication goes
off.
- The ENTRY AFT/DIM2 indication comes
on.

In the cabin:
- The fluorescent tubes in the aft
entry area come on with 10%
intensity.

On the FAP 120RH:

- Push the ENTRY AFT/DIM2 key - The ENTRY AFT/DIM2 indication goes
again. off.

In the cabin:
- The fluorescent tubes in the aft
entry area go off.

R **ON A/C 902-999,

R Subtask 33-21-00-710-051-B

R B. Test of the Forward and Aft Entrance Lighting from the Flight Attendant
R Panel (FAP) 120RH

R (1) Do this test:

R -------------------------------------------------------------------------------
R ACTION RESULT
R -------------------------------------------------------------------------------

R 1. On the FAP 120RH: On the FAP 120RH:

R - Set the LIGHT page. - All possible cabin lighting zones are
R shown.

R - Push the FWD ENTRY/BRT key. - The FWD ENTRY/BRT indication comes
R on.

R In the cabin:


R

EFF :

101-199, 901-999,  33-21-00

Page 509
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
R - The fluorescent tubes in the forward
R entry area come on with 100%
R intensity.

R On the FAP 120RH:

R - Push the FWD ENTRY/DIM1 key. - The FWD ENTRY/BRT indication goes
R off.
R - The FWD ENTRY/DIM1 indication comes
R on.

R In the cabin:
R - The fluorescent tubes in the forward
R entry area come on with 50%
R intensity.

R On the FAP 120RH:

R - Push the FWD ENTRY/DIM2 key. - The FWD ENTRY/DIM1 indication goes
R off.
R - The FWD ENTRY/DIM2 indication comes
R on.

R In the cabin:
R - The fluorescent tubes in the forward
R entry area come on with 10%
R intensity.

R On the FAP 120RH:

R - Push the FWD ENTRY/DIM2 key - The FWD ENTRY/DIM2 indication goes
R again. off.

R In the cabin:
R - The fluorescent tubes in the forward
R entry area go off.

R On the FAP 120RH:

R - Push the FWD ENTRY/BRT key. - The FWD ENTRY/BRT indication comes
R on.

R In the cabin:


R

EFF :

902-999,  33-21-00

Page 510
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
R - The fluorescent tubes in the forward
R entry area come on with 100%
R intensity.

R On the FAP 120RH:

R - Push the AFT ENTRY/BRT key. - The AFT ENTRY/BRT indication comes
R on.

R In the cabin:
R - The fluorescent tubes in the aft
R entry area come on with 100%
R intensity.

R On the FAP 120RH:

R - Push the AFT ENTRY/DIM1 key. - The AFT ENTRY/BRT indication goes
R off.
R - The AFT ENTRY/DIM1 indication comes
R on.

R In the cabin:
R - The fluorescent tubes in the aft
R entry area come on with 50%
R intensity.

R On the FAP 120RH:

R - Push the AFT ENTRY/DIM2 key. - The AFT ENTRY/DIM1 indication goes
R off.
R - The AFT ENTRY/DIM2 indication comes
R on.

R In the cabin:
R - The fluorescent tubes in the aft
R entry area come on with 10%
R intensity.

R On the FAP 120RH:

R - Push the AFT ENTRY/DIM2 key - The AFT ENTRY/DIM2 indication goes
R again. off.

R In the cabin:


R

EFF :

902-999,  33-21-00

Page 511
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
R - The fluorescent tubes in the aft
R entry area go off.

R **ON A/C 001-012, 014-099,

R Subtask 33-21-00-710-052

R C. Test of the Cabin Window and Ceiling Lighting from the Forward Attendant
R Panel (FAP).

R (1) Do this Test.

R -------------------------------------------------------------------------------
R ACTION RESULT
R -------------------------------------------------------------------------------

R 1. On the Forward Attendant Panel In the cabin:


R (FAP) 120RH:

R - push the CABIN LIGHTING BRT - the window and ceiling lights come
R membrane switch. on.

R On the FAP 120RH:


R - the CABIN LIGHTING BRT internal light
R on the membrane switch comes on.
R - the WDO and CLG internal lights on
R the membrane switches come on.

R In the cabin:

R - push the CABIN LIGHTING DIM1 - the window and ceiling lights become
R membrane switch. dim.

R On the FAP 120RH:


R - the CABIN LIGHTING BRT internal light
R on the membrane switch goes off.
R - the CABIN LIGHTING DIM1 internal
R light on the membrane switch comes
R on.

R In the cabin:


R

EFF :

001-012, 014-099, 902-999,  33-21-00

Page 512
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
R - push the CABIN LIGHTING DIM2 - the window and ceiling lights dim
R membrane switch. again.

R On the FAP 120RH:


R - the CABIN LIGHTING DIM1 internal
R light on the membrane switch goes
R off.
R - the CABIN LIGHTING DIM2 internal
R light on the membrane switch comes
R on.

R In the cabin:

R - push the CABIN LIGHTING BRT - the window and ceiling lights become
R membrane switch. bright.

R On the FAP 120RH:


R - the CABIN LIGHTING DIM2 internal
R light on the membrane switch goes
R off.
R - the CABIN LIGHTING BRT internal light
R on the membrane switch comes on.

R In the cabin:

R - push the WDO membrane switch. - the window lights go off.

R On the FAP 120RH:


R - the WDO internal light on the
R membrane switch goes off.

R In the cabin:

R - push the CLG membrane switch. - the ceiling lights go off.

R On the FAP 120RH:


R - the CLG and CABIN LIGHTING BRT
R internal lights on the membrane
R switches go off.

R In the cabin:

R - push the CABIN LIGHTING BRT - the window and ceiling lights come
R membrane switch. on.


R

EFF :

001-012, 014-099,  33-21-00

Page 513
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
On the FAP 120RH:
- the CABIN LIGHTING BRT, WDO and CLG
internal lights on the membrane
switches come on.

In the cabin:

- push the CABIN LIGHTING BRT - the window and ceiling lights go off.
membrane switch.

On the FAP 120RH:


- the CABIN LIGHTING BRT, WDO and CLG
internal lights on the membrane
switches go off.

**ON A/C 101-199, 901-999,

Subtask 33-21-00-710-052-A

C. Test of the Cabin Window and Ceiling Lighting from the Flight Attendant
Panel (FAP) 120RH

R (1) Do this test:

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the FAP 120RH: On the FAP 120RH:

- Set the LIGHT page. - All possible cabin lighting zones are
shown.

- Push the BRT key. - The BRT indication comes on.

In the cabin:
- The fluorescent tubes come on with
100% intensity.

On the FAP 120RH:

- Push the WDO key. - The WDO indication goes off.



EFF :

ALL  33-21-00

Page 514
Feb 01/08
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
In the cabin:
- The fluorescent tubes of the window
lights go off.

On the FAP 120RH:

- Push the WDO key again. - The WDO indication comes on.

In the cabin:
- The fluorescent tubes of the window
lights come on again with 100%
intensity.

On the FAP 120RH:

- Push the AISLE key. - The AISLE indication goes off.

In the cabin:
- The fluorescent tubes of the ceiling
lights go off.

On the FAP 120RH:

- Push the AISLE key again. - The AISLE indication comes on.

- The fluorescent tubes of the ceiling


lights come on again with 100%
intensity.

On the FAP 120RH:

- Push the DIM1 key. - The BRT indication goes off.


- The DIM1 indication comes on.

In the cabin:
- The fluorescent tubes come on with
50% intensity.

On the FAP 120RH:

- Push the DIM2 key. - The DIM1 indication goes off.


- The DIM2 indication comes on.

In the cabin:


R

EFF :

101-199, 901-999,  33-21-00

Page 515
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- The fluorescent tubes come on with
10% intensity.

On the FAP 120RH:

- Push the DIM2 key again. - The DIM2 indication goes off.

In the cabin:
- The fluorescent tubes go off.

Subtask 33-21-00-710-054

D. Test of the aft Entrance Lighting from the Additional Attendant Panel
(AAP)

R (1) Do this test:

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the AAP 126RH: On the AAP 126RH:

- Push the ENTRY BRT membrane - The ENTRY BRT indication comes on.
switch.

In the aft entry area:


- The fluorescent tubes come on with
100% intensity.

On the AAP 126RH:

- Push the ENTRY DIM1 membrane - The ENTRY BRT indication goes off.
switch. - The ENTRY DIM1 indication comes on.

In the aft entry area:


- The fluorescent tubes come on with
50% intensity.

On the AAP 126RH:

- Push the ENTRY DIM2 membrane - The ENTRY DIM1 indication goes off.
switch. - The ENTRY DIM2 indication comes on.



EFF :

101-199, 901-999,  33-21-00

Page 516
Feb 01/08
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
In the aft entry area:
- The fluorescent tubes come on with
10% intensity.

On the AAP 126RH:

- Push the ENTRY DIM2 membrane - The ENTRY DIM2 indication goes off.
switch again.

In the aft entry area:


- The fluorescent tubes go off.

Subtask 33-21-00-710-055

E. Test of the Cabin Window and Ceiling Lighting from the Additional
Attendant Panel (AAP)

R (1) Do this test:

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the AAP 126RH: On the AAP 126RH:

- Push the CABIN BRT membrane - The CABIN BRT light on the membrane
switch. switch comes on.

In the cabin:
- The fluorescent tubes come on with
100% intensity.

On the AAP 126RH:

- Push the CABIN DIM1 membrane - The CABIN BRT light on the membrane
switch. switch goes off.
- The CABIN DIM1 light on the
membrane switch comes on.

In the cabin:
- The fluorescent tubes come on with
50% intensity.

On the AAP 126RH:



EFF :

101-199, 901-999,  33-21-00

Page 517
Feb 01/08
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- Push the CABIN DIM2 membrane - The CABIN DIM1 light on the
switch. membrane switch goes off.
- The CABIN DIM2 light on the
membrane switch comes on.

In the cabin:
- The fluorescent tubes come on with
10% intensity.

On the AAP 126RH:

- Push the CABIN DIM2 membrane - The CABIN DIM2 light on the
switch again. membrane switch goes off.

In the cabin:
- The fluorescent tubes go off.

**ON A/C ALL

Subtask 33-21-00-710-060

F. Test of the Dimming for the Forward-Left Entrance Lighting

WARNING : MAKE SURE THAT YOU OPEN THE CIRCUIT BREAKERS AS FOLLOWS:
_______
- 1JH, 2JH1 AND 3JH1 BEFORE 2KS1
- 1JH, 2JH2 AND 3JH2 BEFORE 2KS2.
IF YOU DO NOT OBEY THIS SEQUENCE, THERE IS A RISK OF
ELECTROCUTION. THIS IS BECAUSE YOU WILL START CONTINUOUS
IGNITION IF YOU OPEN CIRCUIT BREAKER 2KS1 OR 2KS2 FIRST.

R (1) Do this test:

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the FAP 120RH: At the forward entrance:

- Push the ENTRY FWD BRT - The forward entrance lights come on.
button.

2. At the cockpit door: At the cockpit door:



EFF :

ALL  33-21-00

Page 518
Feb 01/08
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- Open the cockpit door. - The cockpit door is open.

3. In the cockpit on the circuit In the cockpit on the circuit breaker


breaker panel 121VU: panel 121VU:

- Open the circuit breakers - The circuit breakers


ENGINE/IGN/ENG2/SYS A BAT, 2JH2 ENGINE/IGN/ENG2/SYS A BAT, 2JH2 and
and ENGINE/IGN/ENG2/SYS B, ENGINE/IGN/ENG2/SYS B, 3JH2 are open.
3JH2.

4. On the overhead circuit breaker On the overhead circuit breaker panel


panel 49VU: 49VU:

- Open the circuit breaker ENG2 - The circuit breaker ENG2 FADEC A EIU,
FADEC A EIU, 2KS2. 2KS2 is open.

5. In the cabin: At the forward entrance:


- The forward-left entrance light dims
to the same light intensity as DIM2.

- Close the cockpit door. - The forward-left entrance light


becomes bright.

- Open the cockpit door. - The forward-left entrance light dims


again to the same light intensity as
DIM2.

6. In the cockpit on the overhead At the forward entrance:


circuit breaker panel 49VU:

- Close the circuit breaker ENG2 - The forward-left entrance light


FADEC A EIU2, 2KS2. becomes bright.

7. On the circuit breaker panel On the circuit breaker panel 121VU:


121VU:

- Close the circuit breakers - The circuit breakers


ENGINE/IGN/ENG2/SYS A BAT, 2JH2 ENGINE/IGN/ENG2/SYS A BAT, 2JH2 and
R and ENGINE/IGN/ENG2/SYS B, ENGINE/IGN/ENG2/SYS B, 3JH2 are
R 3JH2. closed.

8. On the FAP 120RH: At the forward entrance:



EFF :

ALL  33-21-00

Page 519
Feb 01/08
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- Push the ENTRY FWD BRT - The forward entrance lights go off.
button.

Subtask 33-21-00-710-062

G. Test of the Cabin Decompression Simulation

R NOTE : The removal and installation procedure for the cabin pressure
____
R controller 11HL/12HL is given in (Ref. TASK 21-31-34-000-001) and
R (Ref. TASK 21-31-34-400-001).

R (1) Do this test:

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

R 1. On the FAP 120RH: In the cabin and the entrance areas:

R - Push the buttons that follow: - The fluorescent tubes come on with
DIM1 50% intensity.
ENTRY FWD/DIM1
ENTRY AFT/DIM1.

R 2. In the avionics compartment: In the avionics compartment:

R - Remove the CABIN PRESSURE 1 - The CABIN PRESSURE 1 controller


R controller 11HL from 95VU. 11HL from 95VU is removed.
R

R In the cabin and the entrance areas:

R - Ground the pin A11 of the - The fluorescent tubes come on with
R connector 11HL-AA. 100% intensity.

R - Disconnect the ground cable - The fluorescent tubes come on with


R from pin A11 of the connector 50% intensity.
R 11HL-AA.
R

R In the avionics compartment:



EFF :

ALL  33-21-00

Page 520
Feb 01/08
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
R - Install the CABIN PRESSURE 1 - The CABIN PRESSURE 1 controller
R controller 11HL in 95VU. 11HL in 95VU is installed.
R

R - Remove the CABIN PRESSURE 2 - The CABIN PRESSURE 2 controller


R controller 12HL from 96VU. 12HL from 96VU is removed.
R

R In the cabin and the entrance areas:

R - Ground the pin A11 of the - The fluorescent tubes come on with
R connector 12HL-AA. 100% intensity.

R - Disconnect the ground cable - The fluorescent tubes come on with


R from pin A11 of the connector 50% intensity.
R 12HL-AA.
R

R In the avionics compartment:

R - Install the CABIN PRESSURE 2 - The CABIN PRESSURE 2 controller


R controller 12HL in 96VU. 12HL in 96VU is installed.

5. Close-up
________

Subtask 33-21-00-862-050

R A. Put the aircraft back to the serviceable condition.

(1) De-energize the CIDS (Ref. TASK 23-73-00-862-001).

(2) De-energize the aircraft electrical circuit (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-21-00

Page 521
Feb 01/08
 
IAC 
**ON A/C 101-199, 901-999,

TASK 33-21-00-740-002

R Bite Test of the General Illumination with the MCDU

1. __________________
Reason for the Job

To make sure that the general illumination operates correctly.

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

23-73-00-861-001 Energize the Cabin Intercommunication Data System


(CIDS)
23-73-00-862-001 De-energize the Cabin Intercommunication Data System
(CIDS)
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
31-32-00-860-003 Procedure to Get Access to the SYSTEM REPORT/TEST/COM
Page

3. __________
Job Set-up

Subtask 33-21-00-861-051

A. Aircraft Maintenance Configuration

(1) Energize the aircraft electrical circuits


(Ref. TASK 24-41-00-861-002).

(2) Energize the Cabin Intercommunication Data-System (CIDS) (Ref. TASK


23-73-00-861-001).

(3) Procedure to get access to the SYSTEM REPORT/TEST/COM Page (Ref. TASK
31-32-00-860-003).



EFF :

101-199, 901-999,  33-21-00

Page 522
Feb 01/08
 
IAC 
Subtask 33-21-00-865-051

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU CAB LIGHT PWR-CEILING-AFT 307LG H08
2000VU CAB LIGHT PWR-CEILING-AFT 304LG H07
2000VU CAB LIGHT PWR-CEILING-FWD 306LG H06
2000VU CAB LIGHT PWR-CEILING-FWD 305LG H05
2000VU CAB LIGHT PWR-WINDOW-AFT 302LG H04
2000VU CAB LIGHT PWR-WINDOW-AFT 301LG H03
2000VU CAB LIGHT PWR-WINDOW-FWD 303LG H02
2000VU CAB LIGHT PWR-WINDOW-FWD 300LG H01
2000VU LIGHT-CABIN-ENTRY 308LG J02

4. Procedure
_________

Subtask 33-21-00-740-050

A. BITE-test of the General Illumination on the Multipurpose Control and


Display Unit (MCDU) 3CA

R (1) Do this test:

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the MCDU: On the MCDU screen:

R - Push the line select key - The CIDS main menu page comes into
R adjacent to the CIDS 1 view.
indication.

R - Push the line select key - The SYSTEM/TESTS menu page comes into
R adjacent to the SYSTEM TESTS view.
indication.

R - Push the line select key - The ILLUMINATION TEST menu page comes
R adjacent to the ILLUMINATION into view.
TEST indication.

- Push the line select key - TEST IN PROGRESS 5s shows on the


adjacent to the START TEST display.
indication.



EFF :

101-199, 901-999,  33-21-00

Page 523
Feb 01/08
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
In the cabin:
- All the cabin lights come on for
approx. 5s.

On the MCDU screen:


- TEST OK shows on the display.

R - Push the line select key - The CIDS main menu page comes into
R adjacent to the RETURN view.
indication.

5. Close-up
________

Subtask 33-21-00-862-051

A. Put the aircraft back to the serviceable condition.

(1) On the MCDU, set the BRT knob to the OFF position.

(2) De-energize the CIDS (Ref. TASK 23-73-00-862-001).

(3) De-energize the aircraft electrical circuits


(Ref. TASK 24-41-00-862-002).



EFF :

101-199, 901-999,  33-21-00

Page 524
Feb 01/08
 
IAC 
BALLAST UNIT WITH LAMPHOLDER - REMOVAL/INSTALLATION
___________________________________________________

TASK 33-21-11-000-001

Removal of the Ballast Unit and Lampholder 1LG1 (3LG1)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

NOTE : The procedure is the same for all the passenger cabin lighting in Zone
____
200.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific stepladder 1.0 m (3 ft. 3 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

25-23-41-000-001 Removal of the Ceiling Panels


25-23-48-000-001 Removal of the Cove Light Panels

R **ON A/C 001-012, 014-099,

33-21-11-991-001 Fig. 401



EFF :

ALL  33-21-11

Page 401
Feb 01/08
 
IAC 
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R **ON A/C 101-199, 901-999,

R 33-21-11-991-001-A Fig. 401A

R **ON A/C ALL

3. __________
Job Set-up

Subtask 33-21-11-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-099,

2000VU LIGHT-CABIN-ENTRY 308LG J04

**ON A/C ALL

2000VU CAB LIGHT PWR-CEILING-AFT 307LG H08


2000VU CAB LIGHT PWR-CEILING-AFT 304LG H07
2000VU CAB LIGHT PWR-CEILING-FWD 306LG H06
2000VU CAB LIGHT PWR-CEILING-FWD 305LG H05
2000VU CAB LIGHT PWR-WINDOW-AFT 302LG H04
2000VU CAB LIGHT PWR-WINDOW-AFT 301LG H03
2000VU CAB LIGHT PWR-WINDOW-FWD 303LG H02
2000VU CAB LIGHT PWR-WINDOW-FWD 300LG H01

**ON A/C 101-199, 901-999,

2000VU LIGHT-CABIN-ENTRY 308LG J02



EFF :

ALL  33-21-11

Page 402
Feb 01/08
 
IAC 
**ON A/C ALL

Subtask 33-21-11-010-050

B. Get Access

(1) For the ceiling ballast unit and lampholder:


- put the stepladder below the related ceiling panel.
- remove the related ceiling panel (Ref. TASK 25-23-41-000-001).

(2) For the window ballast unit and lampholder:


- remove the related cove light panel (Ref. TASK 25-23-48-000-001).

(3) Find the ballast unit and lampholder (6).

4. Procedure
_________

R **ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-21-11-991-001)

R **ON A/C 101-199, 901-999,

R (Ref. Fig. 401A/TASK 33-21-11-991-001-A)

R **ON A/C 001-012, 014-099,

Subtask 33-21-11-020-050

A. Removal of the Ballast Unit with Lampholder and the Tube

(1) Remove the tube (2)

(a) Push the buttons (1) at each end of the lampholder (6) and remove
the fluorescent tube (2).

(b) Retain the tube (2).

(2) Remove the window ballast unit and lampholder (6)

(a) Disconnect the electrical connectors (3).

(b) Put blanking caps on the disconnected electrical connectors.



EFF :

ALL  33-21-11

Page 403
Feb 01/08
 
IAC 
Ballast Unit and Lampholder
Figure 401/TASK 33-21-11-991-001- 12 (SHEET 1)


R

EFF :

001-012, 014-099,  33-21-11

Page 404
Feb 01/08
 
IAC 
Ballast Unit and Lampholder
Figure 401/TASK 33-21-11-991-001- 22 (SHEET 2)


R

EFF :

001-012, 014-099,  33-21-11

Page 405
Feb 01/08
 
IAC 
R Advanced Integrated Ballast-Unit (AIBU) with Lampholder
R Figure 401A/TASK 33-21-11-991-001-A


R

EFF :

101-199, 901-999,  33-21-11

Page 406
Feb 01/08
 
IAC 
(c) Remove the screws (5) and the washers (4).

(d) Remove the ballast unit and lampholder (6) from the airframe
structure.

(3) Remove the ceiling and the entrance ballast unit and lampholder (6)

(a) Disconnect the electrical connectors (3).

(b) Put blanking caps on the disconnected electrical connectors.

(c) Remove the screws (8) and the washers (7).

(d) Remove the ballast unit and lampholder (6) from the airframe
structure.

R **ON A/C 101-199, 901-999,

R Subtask 33-21-11-020-050-A

R A. Removal of the Advanced Integrated Ballast-Unit (AIBU) with Lampholder

R (1) Identify all electrical connectors (1) before you disconnect them.

R (2) Disconnect the electrical connector (1).

R NOTE : If necessary remove and discard the cable ties.


____

R (3) Put blanking caps on the disconnected electrical connectors.

R (4) Hold the fluorescent tube (5) and push the buttons (2) at each end of
R the lampholder (7) to remove the fluorescent tube (5).

R (5) Remove the screws (4) and the washers (3).

R (6) If installed remove the reflector (6).

R (7) Remove the AIBU with lampholder (7).



EFF :

ALL  33-21-11

Page 407
Feb 01/08
 
IAC 
R **ON A/C ALL

TASK 33-21-11-400-001

Installation of the Ballast Unit and Lampholder 1LG1

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

R A. Fixtures, Tools, Test and Support Equipment

R -------------------------------------------------------------------------------
R REFERENCE QTY DESIGNATION
R -------------------------------------------------------------------------------

R No specific cable ties

R B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

23-73-00-861-001 Energize the Cabin Intercommunication Data System


(CIDS)
23-73-00-862-001 De-energize the Cabin Intercommunication Data System
(CIDS)
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
25-23-41-400-001 Installation of the Ceiling Panels
25-23-48-400-001 Installation of the Cove Light Panels

R **ON A/C 001-012, 014-099,

33-21-11-991-001 Fig. 401

R **ON A/C 101-199, 901-999,

R 33-21-11-991-001-A Fig. 401A



EFF :

ALL  33-21-11

Page 408
Feb 01/08
 
IAC 
R **ON A/C ALL

3. __________
Job Set-up

Subtask 33-21-11-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-099,

2000VU LIGHT-CABIN-ENTRY 308LG J04

**ON A/C ALL

2000VU CAB LIGHT PWR-CEILING-AFT 307LG H08


2000VU CAB LIGHT PWR-CEILING-AFT 304LG H07
2000VU CAB LIGHT PWR-CEILING-FWD 306LG H06
2000VU CAB LIGHT PWR-CEILING-FWD 305LG H05
2000VU CAB LIGHT PWR-WINDOW-AFT 302LG H04
2000VU CAB LIGHT PWR-WINDOW-AFT 301LG H03
2000VU CAB LIGHT PWR-WINDOW-FWD 303LG H02
2000VU CAB LIGHT PWR-WINDOW-FWD 300LG H01

**ON A/C 101-199, 901-999,

2000VU LIGHT-CABIN-ENTRY 308LG J02

**ON A/C ALL

4. Procedure
_________

R **ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-21-11-991-001)



EFF :

ALL  33-21-11

Page 409
Feb 01/08
 
IAC 
R **ON A/C 101-199, 901-999,

R (Ref. Fig. 401A/TASK 33-21-11-991-001-A)

R **ON A/C ALL

Subtask 33-21-11-910-051

A. Preparation for Installation

(1) Make sure that the parts retained from the removed component are
clean and in the correct condition.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Clean the component interface and/or the adjacent area.

R **ON A/C 001-012, 014-099,

Subtask 33-21-11-420-050

B. Installation of the Ballast Unit with Lampholder and the Tube

(1) Installation of the ceiling and the entrance ballast unit and
lampholder

(a) Install the ceiling and the entrance ballast unit and lampholder
(6) to the fuselage structure with the washers (7) and the screws
(8).

(b) Remove the blanking caps from the electrical connectors.

(c) Connect the electrical connector (3).

(2) Installation of the window ballast unit and lampholder

(a) Install the window ballast unit and lampholder (6) to the
fuselage structure with the washers (4) and the screws (5).

(b) Remove the blanking caps from the electrical connectors.

(c) Connect the electrical connector (3).


R

EFF :

ALL  33-21-11

Page 410
Feb 01/08
 
IAC 
(3) Installation of the tube

(a) Install the fluorescent tube (2) to the lampholder (6).

R **ON A/C 101-199, 901-999,

R Subtask 33-21-11-420-050-A

R B. Installation of the Advanced Integrated Ballast-Unit (AIBU) with


R Lampholder

R (1) Clean the component interface and/or the adjacent area.

R (2) Do an inspection of the component interface and/or the adjacent area.

R (3) Put the AIBU with lampholder (7) in the correct position on the
R aircraft structure.

R (4) If removed, put the reflector (6) in the correct position on the AIBU
R with lampholder (7).

R (5) Install the washer (3) and the screws (4).

R (6) Installation of the Fluorescent Tube

R CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
R THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF
R THE LAMP.
R IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
R LINT-FREE CLOTH.

R (a) Install the fluorescent tube (5) in the lampholder (7).

R (7) Remove the blanking caps from the electrical connectors.

R (8) Make sure that the electrical connectors are clean and in the correct
R condition.

R (9) Connect the electrical connector (1) as identified during the removal
R procedure.

R (10) If necessary attach the electrical wire with cable ties.



EFF :

ALL  33-21-11

Page 411
Feb 01/08
 
IAC 
R **ON A/C ALL

Subtask 33-21-11-865-052

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
R
R 300LG, 301LG, 302LG, 303LG, 304LG, 305LG, 306LG, 307LG, 308LG

R **ON A/C 001-012, 014-099,

Subtask 33-21-11-860-050

D. Preparation for the test

(1) Energize the aircraft electrical circuit (Ref. TASK 24-41-00-861-


002).

(2) Energize the Cabin Intercommunication Data System (CIDS) (Ref. TASK
23-73-00-861-001).

(3) Make sure that the cockpit door is closed and the engines are not
running.

(4) Push the MAIN OFF membrane switch on the forward attendant panel
120RH.

(5) Make sure that the integral lights on all BRT, DIM1, DIM2, WDO and
CLG membrane switches on the forward attendant panel 120RH are off.


R

EFF :

ALL  33-21-11

Page 412
Feb 01/08
 
IAC 
Subtask 33-21-11-710-050

E. Test of the Entrance-, Window- and Ceiling-Lights

(1) Do the operational test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. For the entrance lighting: At the related entrance light position:


On the forward attendant panel:

- push the ENTRY BRT pushbutton - the related entrance light comes on.
switch. - the ENTRY BRT integral light on the
related pushbutton comes on.

- push the ENTRY DIM 1 pushbutton - the related entrance light intensity
switch. decreases.
- the ENTRY DIM 1 integral light on the
related pushbutton comes on.

- push the ENTRY DIM 2 pushbutton - the related entrance light intensity
switch. decreases again.
- the ENTRY DIM 2 integral light on the
related pushbutton comes on.

- push the ENTRY DIM 2 pushbutton - the related entrance light goes off.
switch. - the ENTRY DIM 2 integral light on the
related pushbutton goes off.

2. For the window or ceiling At the related window or ceiling light


lighting: position:
On the forward attendant panel:

- push the BRT pushbutton switch. - the related window or ceiling light
comes on.
- the BRT integral light on the related
pushbutton comes on.

- push the DIM 1 pushbutton - the related window or ceiling light


switch. intensity decreases.
- the DIM 1 integral light on the
related pushbutton comes on.

- push the DIM 2 pushbutton - the related window or ceiling light


switch. intensity decreases again.


R

EFF :

001-012, 014-099,  33-21-11

Page 413
Feb 01/08
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- the DIM 2 integral light on the
related pushbutton comes on.

- push the DIM 2 pushbutton - the related window or ceiling light


switch. goes off.
- the DIM 2 integral light on the
related pushbutton goes off.

R **ON A/C 101-199, 901-999,

Subtask 33-21-11-860-050-A

D. Preparation for the test

(1) Energize the aircraft electrical circuit (Ref. TASK 24-41-00-861-


002).

(2) Energize the Cabin Intercommunication Data System (CIDS) (Ref. TASK
23-73-00-861-001).

(3) Make sure that the cockpit door is closed and the engines are not
running.

(4) Push the LIGHT MAIN ON/OFF membrane switch on the Flight Attendant
Panel (FAP) 120RH.

(5) Make sure that the indication on all of the BRT, DIM1, DIM2, WDO and
CLG buttons on the FAP 120RH are off.



EFF :

ALL  33-21-11

Page 414
Feb 01/08
 
IAC 
Subtask 33-21-11-710-050-A

E. Test of the Entrance-Lights, Window-Lights and Ceiling-Lights

(1) Do the operational test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. For the entrance lighting:

On the Flight Attendant Panel On the FAP 120RH:


(FAP) 120RH:

- Set the LIGHT page. - All possible cabin lighting zones are
shown.

- Push the ENTRY/BRT button. - The ENTRY/BRT indication on the


related button comes on.

In the cabin:
- The related entrance light comes on.

On the FAP 120RH:

- Push the ENTRY/DIM1 button. - The ENTRY/DIM1 indication on the


related button comes on.

In the cabin:
- The related entrance light intensity
decreases.

On the FAP 120RH:

- Push the ENTRY/DIM2 button. - The ENTRY/DIM2 indication on the


related button comes on.

In the cabin:
- The related entrance light intensity
decreases again.

On the FAP 120RH:

- Push the ENTRY/DIM2 button - The ENTRY/DIM2 indication on the


again. related button goes off.



EFF :

101-199, 901-999,  33-21-11

Page 415
Feb 01/08
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
In the cabin:
- The related entrance light goes off.

2. For the window or ceiling


lighting:

On the FAP 120RH: On the FAP 120RH:

- Push the BRT button. - The BRT indication on the related


button comes on.

In the cabin:
- The related window or ceiling light
comes on.

On the FAP 120RH:

- Push the DIM1 button. - The DIM1 indication on the related


button comes on.

In the cabin:
- The related window or ceiling light
intensity decreases.

On the FAP 120RH:

- Push the DIM2 button. - The DIM2 indication on the related


button comes on.

In the cabin:
- The related window or ceiling light
intensity decreases again.

On the FAP 120RH:

- Push the DIM2 button again. - The DIM2 indication on the related
button goes off.

In the cabin:
- The related window or ceiling light
goes off.



EFF :

101-199, 901-999,  33-21-11

Page 416
Feb 01/08
 
IAC 
**ON A/C ALL

5. Close-up
________

Subtask 33-21-11-410-051

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) For the ceiling ballast unit and lampholder:


- install the related ceiling panel (Ref. TASK 25-23-41-400-001).

(3) For the window ballast unit and lampholder:


- install the related cove light panel (Ref. TASK 25-23-48-400-001).

(4) Remove the stepladder

Subtask 33-21-11-862-050

B. Put the aircraft back to the serviceable condition.

(1) De-energize the CIDS (Ref. TASK 23-73-00-862-001).

(2) De-energize the aircraft electrical circuits


(Ref. TASK 24-41-00-862-002).



EFF :

ALL  33-21-11

Page 417
Feb 01/08
 
IAC 
SWITCH - CABIN ENTRANCE LIGHT DIMMING (310LG) - REMOVAL/INSTALLATION
____________________________________________________________________

TASK 33-21-12-000-001

Removal of the Cabin Entrance Light Dimming Switch (310LG)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-21-12-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-21-12-010-050

A. Get Access

(1) Open the cockpit door.



EFF :

ALL  33-21-12

Page 401
May 01/07
R  
IAC 
Subtask 33-21-12-865-050

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------

R **ON A/C 001-012, 014-099,

R 2000VU LIGHT-CABIN-ENTRY 308LG J04

R **ON A/C 101-199, 901-999,

2000VU LIGHT-CABIN-ENTRY 308LG J02

R **ON A/C ALL

4. Procedure
_________

Subtask 33-21-12-020-050

A. Removal of the Limit Switch 310LG


(Ref. Fig. 401/TASK 33-21-12-991-001)

(1) Remove the screws (11) and the bracket (12) from the cockpit wall
(1).

(2) Carefully remove the switch bracket (8) together with the limit
switch (3) from the insert of the cockpit wall (1).

(3) Cut and remove the lockwire from the adjustment nut (6) and the lock
nut (10).

(4) Remove the lock nut (10) and the serrated washer (9) from the limit
switch (3).

(5) Remove the limit switch (3) together with the adjustment nut (6) and
the lock washer (7) from the swtich bracket (3).

(6) Disconnect the wires of the cable harness (2) from the limit switch
(3). Tag and identify each wire as it is disconnected.

(7) Put blanking caps on the disconnected electrical connectors.



EFF :

ALL  33-21-12

Page 402
May 01/07
 
IAC 
R Cabin Entrance Light Dimming Switch
Figure 401/TASK 33-21-12-991-001



EFF :

ALL  33-21-12

Page 403
Nov 01/05
 
IAC 
TASK 33-21-12-400-001

Installation of the Cabin Entrance Light Dimming Switch (310LG)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific red blanking plugs

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-21-00-710-001 Operational Test of the General Illumination


33-21-12-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-21-12-860-050

A. Aircraft Maintenance Configuration

(1) Make sure that the cockpit door is opened.



EFF :

ALL  33-21-12

Page 404
May 01/06
R  
IAC 
Subtask 33-21-12-865-051

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------

R **ON A/C 001-012, 014-099,

R 2000VU LIGHT-CABIN-ENTRY 308LG J04

R **ON A/C 101-199, 901-999,

2000VU LIGHT-CABIN-ENTRY 308LG J02

R **ON A/C ALL

4. Procedure
_________

(Ref. Fig. 401/TASK 33-21-12-991-001)

Subtask 33-21-12-210-050

A. Visual Inspection

(1) Make sure that the parts retained from the removed component are
clean and in the correct condition.

(2) Clean the component interface and/or the adjacent area.

(3) Do an inspection of the component interface and/or the adjacent area.

(4) Make sure that the wires of the cable harness (2) are in a good
condition.



EFF :

ALL  33-21-12

Page 405
May 01/07
 
IAC 
Subtask 33-21-12-560-050

B. Preparation of the Limit Switch

(1) Make sure that the roller (5) of the replaced limit switch (3) is
turned 90 degrees to the groove.

(2) If not, put the roller (5) in the correct position as follows:

(a) Remove the nut (14) and the bolt (4) from the fork end (13).

(b) Disengage the roller (5) from the fork end (14).

(c) Push the fork end (13) carefully into the switch housing with a
suitable tool until you feel resistance and hold.

(d) Turn the fork end (13) to 90 degrees and release it.

(e) Put the roller (5) in the fork end (13) and install the bolt (4)
and the nut (14).

(f) Tighten the nut (14) correctly.

Subtask 33-21-12-420-050

C. Installation of the Limit Switch 310LG

(1) Put the limit switch (3) together with the related adjustment nut (6)
and the lock washer (7) in position on the switch bracket (8).

NOTE : Make sure that the outer tab of the lock washer (7) engages in
____
the attachment hole of the switch bracket (8).

(2) Make sure that the roller (5) of the limit switch (3) is in the
longitudial direction.

(3) Attach the limit switch (3) on the switch bracket (8) with the
serrated washer (9) and the lock nut (10).

(4) Connect the wires of the cable harness (2) to the terminals of the
limit switch (3).

NOTE : For the correct connection refer to the table Wire Connection
____
to Connector Contacts of the illustration.

(5) Make sure that the contacts, which are not used, are covered with red
blanking plugs.



EFF :

ALL  33-21-12

Page 406
May 01/07
R  
IAC 
(6) Put the switch bracket (8) and the bracket (12) into the slot of the
cockpit wall (1) and attach them with the screws (11).

Subtask 33-21-12-820-050

D. Adjustment of the Limit Switch 310LG

(1) Measure the distance which must be in a range of 7.5 mm (0.2952 in.)
between the lower edge cockpit wall (1) and the end of the roller
(5).

(2) Close the cockpit door and make sure that the limit switch 310LG
operates correctly. If not, loosen the lock nut (10) and turn the
adjustment nut (6) as required.

(3) If the distance is correct, tighten the lock nut (10).

Subtask 33-21-12-865-052

E. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
308LG

Subtask 33-21-12-710-050

F. Do the opertional test for the dimming of the forward entrance lighting
(Ref. TASK 33-21-00-710-001).

5. Close-up
________

Subtask 33-21-12-410-050

A. Close Access

(1) Close the cockpit door.



EFF :

ALL  33-21-12

Page 407
May 01/07
R  
IAC 
CALL SYSTEM (SEE ALSO 23-73-00) - DESCRIPTION AND OPERATION
___________________________________________________________

1. _______
General
The Call System Circuit RH is described in the Cabin Intercommunication Data
System (CIDS) (Ref. 23-73-00).



EFF :

ALL  33-23-00

Page 1
Feb 01/96
 
IAC 
LAVATORY LIGHTING - DESCRIPTION AND OPERATION
_____________________________________________

1. General
_______

**ON A/C 001-012, 014-099,

A. Description
The lavatory lighting system consists of a fluorescent lamp and an
integrated ballast unit installed in each lavatory. A membrane switch
POWER LAV on the forward attendant panel 120RH controls the power for the
lavatory lighting system.

R **ON A/C 101-199, 901-999,

A. The lavatory lighting system has a fluorescent lamp, an integrated


ballast unit and a halogen lamp installed in each lavatory.
The LAV MAINT membrane switch on the Flight Attendant Panel (FAP) 120RH
controls the power for the fluorescent lamps.
A microswitch is installed in each lavatory door frame and controls the
halogen lamp and the lighting level of the fluorescent tube.

**ON A/C ALL

2. __________________
Component Location

**ON A/C 001-012, 014-099,

(Ref. Fig. 001)

-------------------------------------------------------------------------------
FIN FUNCTIONAL DESIGNATION PANEL ZONE ACCESS ATA
DOOR REF.
-------------------------------------------------------------------------------
3LQ BALLAST UNIT 221 33-24-11
3LQ-1 FLUORESCENT LAMP 221 33-24-11
4LQ BALLAST UNIT 261 33-24-11
4LQ-1 FLUORESCENT LAMP 261 33-24-11
5LQ BALLAST UNIT 261 33-24-11
5LQ-1 FLUORESCENT LAMP 261 33-24-11



EFF :

ALL  33-24-00

Page 1
Feb 01/07
 
IAC 
Lavatory Lighting - Component Location
Figure 001


R

EFF :

001-012, 014-099,  33-24-00

Page 2
Aug 01/07
 
IAC 
**ON A/C 101-199, 901-999,

**ON A/C 101-199,

(Ref. Fig. 001A)

R **ON A/C 901-999,

(Ref. Fig. 001B)

**ON A/C 101-199, 901-999,

-------------------------------------------------------------------------------
FIN FUNCTIONAL DESIGNATION PANEL ZONE ACCESS ATA
DOOR REF.
-------------------------------------------------------------------------------
BALLAST UNIT 200 33-24-11
FLUORESCENT LAMP 200 33-24-11
HALOGEN LAMP 200 33-24-12

**ON A/C ALL

3. __________________
System Description

**ON A/C 001-012, 014-099,

The lavatory lighting system comprises:


- a fluorescent lamp and ballast unit, installed adjacent to the lavatory
mirror, in each lavatory.
- a microswitch installed at each lavatory door. The microswitch is part of
the lavatory lighted signs system (Ref. 33-26-00).



EFF :

ALL  33-24-00

Page 3
Aug 01/07
 
IAC 
R Lavatory Lighting - Component Location
R Figure 001A


R

EFF :

101-199,  33-24-00

Page 4
May 01/07
 
IAC 
Lavatory Lighting - Component Location
Figure 001B


R

EFF :

901-999,  33-24-00

Page 5
Aug 01/07
 
IAC 
**ON A/C 101-199, 901-999,

The lavatory lighting system has:


- a fluorescent lamp with a ballast unit installed above the lavatory door
in each lavatory.
- a halogen lamp installed adjacent to the lavatory mirror in each lavatory.
- a microswitch installed at each lavatory door frame. The microswitch is
part of the lavatory lighted signs system (Ref. 33-26-00).

**ON A/C ALL

4. ____________
Power Supply

**ON A/C 001-012, 014-099,

(Ref. Fig. 002)


The 115VAC from the busbar 214XP supplies the system through the circuit
breaker 1LQ and the power control relay 2LQ. The pushbutton membrane-switch
POWER LAV, on the forward attendant panel 120RH, controls the power supply
for the system.

**ON A/C 101-199, 901-999,

**ON A/C 101-199,

(Ref. Fig. 002A)

R **ON A/C 901-999,

(Ref. Fig. 002B)

**ON A/C 101-199, 901-999,

The 115VAC from the busbar 214XP supplies the fluorescent lamps 10LQ with
the integrated ballast units and the mirror light 22LQ through the circuit
breaker 1LQ and the power control relay 21LQ. The MAIN LIGHT ON/OFF button
on the Flight Attendant Panel (FAP) 120RH controls the power supply for the
fluorescent lamps and the mirror light.



EFF :

ALL  33-24-00

Page 6
Aug 01/07
 
IAC 
Lavatory Lighting - Schematic
Figure 002


R

EFF :

001-012, 014-099,  33-24-00

Page 7/8
Aug 01/07
 
IAC 
R Lavatory Lighting - Schematic
R Figure 002A


R

EFF :

101-199,  33-24-00

Page 9
May 01/07
 
IAC 
Lavatory Lighting - Schematic
Figure 002B


R

EFF :

901-999,  33-24-00

Page 10
Aug 01/07
 
IAC 
The 28VDC from the busbar 208PP supplies the halogen lamps through the
circuit breakers 1WJ, 11WJ and the door microswitches (Ref. 33-26-00).

**ON A/C ALL

5. Operation
_________

**ON A/C 001-012, 014-099,

A. Component Operation
The system is supplied with power when the busbars are energized and the
circuit breakers 1LQ, 1WJ and 11WJ are closed. With the door microswitch
in FREE position, 28VDC is supplied to the DIM 1 (50 %) input of the
ballast unit.

(1) When the switch POWER LAV on the forward attendant panel 120RH is
pushed relay 2LQ energizes. Each lavatory ballast unit is supplied
with 115VAC and the fluorescent lamp comes on with 50 % intensity.

(2) When the lavatory door is locked, the respective door microswitch
changes over to the ENGAGED position. The 28VDC to the DIM 1 input of
the ballast unit is disconnected and the fluorescent lamp illuminates
with 100 % intensity.

(3) The integral light under the POWER LAV membrane switch foil (on the
forward attendant panel 120RH) comes on when the membrane switch is
initially pushed.
When the membrane switch is pushed again, the fluorescent lamps in
the lavatory go off. Also the integral light under the POWER LAV
membrane switch foil goes off.

(4) All lavatory lights go off when the membrane switch LIGHT MAIN OFF on
the attendant panel 120RH is pushed. Other systems are also switched
off with this membrane switch at the same time.

**ON A/C 101-199, 901-999,

A. Component Operation
The system is supplied with power when the busbars are energized and the
circuit breakers 1LQ, 1WJ and 11WJ are closed.
With the door microswitch in the FREE position the halogen lamp is
disconnected from the 28VDC. The DIM 1 (50 %) input of the ballast unit
is supplied with 28VDC.



EFF :

ALL  33-24-00

Page 11
Aug 01/07
R  
IAC 
(1) When the MAIN LIGHT ON/OFF button on the FAP 120RH is set to ON, the
relay 2LQ energizes. Each lavatory ballast unit is supplied with
115VAC and the fluorescent lamp comes on with 50 % intensity.
With the LAV MAINT button on the FAP 120RH the light in the
lavatories can be controlled. The fluorescent lamps in the lavatories
switches to 100% intensity (bright), when the LAV MAINT button is
pushed.

(2) When the lavatory door is locked, the related door microswitch
changes over to the ENGAGED position and the halogen lamp is supplied
with 28VDC. The 28VDC is disconnected from the DIM 1 input of the
ballast unit and the fluorescent lamp illuminates with 100 %
intensity.

(3) The lights in the lavatories is on when the LIGHTS MAIN ON/OFF button
on the Flight Attendant Panel(FAP) 120RH is pushed to ON.
When the button is pushed to OFF, the lights in the lavatories are
off.
Through the LAV MAINT button on the FAP the light in the lavatories
can be controlled. As long as the LAV MAINT button is not activated,
the light in the lavatories is dimmed. The light switches to bright,
when the LAV MAINT button is pushed.

(4) All fluorescent tubes go off when the MAIN LIGHT ON/OFF button on the
Flight Attendant Panel (FAP) 120RH is pushed. Other systems are also
go off at the same time.



EFF :

101-199, 901-999,  33-24-00

Page 12
Aug 01/07
R  
IAC 
LAVATORY LIGHTING - ADJUSTMENT/TEST
___________________________________

TASK 33-24-00-710-001

Operational Test of the Lavatory Lighting LQ

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

To make sure that the lavatory lighting operates correctly.

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

23-73-00-861-001 Energize the Cabin Intercommunication Data System


(CIDS)
23-73-00-862-001 De-energize the Cabin Intercommunication Data System
(CIDS)
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-24-00-861-050

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).



EFF :

ALL  33-24-00

Page 501
Feb 01/96
 
IAC 
**ON A/C 001-012, 014-019,

Subtask 33-24-00-865-050-A

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAV LIGHT 1LQ C01
2000VU LAVATORY FORWARD - OCCUPIED 1WJ C06
2001VU LAVATORY AFT OCCUPIED 11WJ E07

**ON A/C 020-099,

Subtask 33-24-00-865-050-B

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAV LIGHT 1LQ C01
2000VU LAVATORY FWD & MID OCCUPIED 1WJ C06
2001VU LAVATORY AFT OCCUPIED 11WJ C07

R **ON A/C 101-199,

R Subtask 33-24-00-865-050-D

R B. Make sure that this(these) circuit breaker(s) is(are) closed:

R -------------------------------------------------------------------------------
R PANEL SERVICE IDENT. LOCATION
R -------------------------------------------------------------------------------
R 2000VU LIGHT - LAV 1LQ J01
R 2000VU LAV FWD & MID - OCCUPIED 1WJ F01
R 2001VU LAVATORY AFT OCCUPIED 11WJ B04


R

EFF :

001-012, 014-099, 101-199,  33-24-00

Page 502
Feb 01/07
 
IAC 
R **ON A/C 901-999,

Subtask 33-24-00-865-050-C

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAV LIGHT 1LQ C01
2000VU LAVATORY FWD & MID OCCUPIED 1WJ C06
2001VU LAVATORY AFT OCCUPIED 11WJ E07

**ON A/C ALL

Subtask 33-24-00-869-051

C. Energize the Cabin Intercommunication Data System (CIDS) (Ref. TASK 23-
73-00-861-001).

4. Procedure
_________

**ON A/C 001-012, 014-099,

Subtask 33-24-00-710-050

A. Test of the Lavatory Lighting.

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the forward attendant panel On the forward attendant panel 120RH:


120RH:
- push the POWER LAV membrane - the green POWER LAV integral light in
switch. the membrane switch comes on.

In the lavatory:

- the lavatory lighting is dim.

2. In the lavatory:



EFF :

ALL  33-24-00

Page 503
Feb 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- close and lock the lavatory - the lavatory lighting becomes bright.
door.

- unlock the lavatory door. - the lavatory lighting becomes dim.

3. On the forward attendant panel At all lavatories:


120RH:
- push the MAIN OFF membrane - the lighting in all the lavatories
switch. goes off.
- push the POWER LAV LIGHT - the lighting in all the lavatories
membrane switch. comes on.

R **ON A/C 101-199, 901-999,

Subtask 33-24-00-710-050-A

A. Test of the Lavatory Lighting

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the flight attendant panel On the FAP 120RH:


(FAP) 120RH:

- push the LIGHTS MAIN ON/OFF - the integral light in the LIGHTS MAIN
membrane switch on the hardkey ON/OFF membrane switch comes on.
panel.

In the cabin:

- the cabin lights come on.

2. In the lavatory: In the lavatory:

- close the lavatory door. - the fluorescent light is on with low


intensity (dim mode).
- the mirror light is off.

3. In the lavatory: In the lavatory:


R

EFF :

ALL  33-24-00

Page 504
Feb 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- lock the lavatory door. - the fluorescent light increases to
full intensity (bright mode).
- the mirror light comes on.

4. In the lavatory: In the lavatory:

- unlock the lavatory door. - the fluorescent light decreases to


low intensity (dim mode).
- the mirror light goes off.

5. On the FAP 120RH: On the FAP 120RH:

- push the LAV MAINT membrane - the integral light in the LAV MAINT
switch on the hardkey panel. membrane switch comes on.

- the fluorescent light increases to


full intensity (bright mode).
- the mirror light comes on.

6. On the FAP 120RH: On the FAP 120RH:

- push the LAV MAINT membrane - the integral light in the LAV MAINT
switch on the hardkey panel. membrane switch goes off.

- the fluorescent light decreases to


low intensity (dim mode).
- the mirror light goes off.

7. On the FAP 120RH: On the FAP 120RH:

- push the LIGHTS MAIN ON/OFF - the integral light in the LIGHTS MAIN
membrane switch on the hardkey ON/OFF membrane switch goes off.
panel.

In the cabin:

- the cabin lights go off.


R

EFF :

101-199, 901-999,  33-24-00

Page 505
Feb 01/07
 
IAC 
**ON A/C ALL

5. Close-up
________

Subtask 33-24-00-860-050

A. Put the aircraft back to the serviceable condition.

(1) De-energize the CIDS (Ref. TASK 23-73-00-862-001).

(2) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-24-00

Page 506
Feb 01/07
 
IAC 
BALLAST UNIT WITH LAMPHOLDER - REMOVAL/INSTALLATION
___________________________________________________

R **ON A/C 001-012, 014-099,

TASK 33-24-11-000-001

Removal of the Ballast Unit and Lampholder 3LQ

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-24-11-991-001 Fig. 401



EFF :

ALL  33-24-11

Page 401
May 01/06
 
IAC 
3. __________
Job Set-up

Subtask 33-24-11-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAV LIGHT 1LQ C01

Subtask 33-24-11-010-050

B. Open the lavatory door.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-24-11-991-001)

Subtask 33-24-11-020-051

A. Removal of the Ballast Unit with Lampholder and the Tube

(1) Removal of the tube

(a) Lift the handle (7) to release the latch.

(b) Open the lower service cabinet door (8).

(c) Remove the screws (9), the washers (10) and the upper service
cabinet door (11).

(d) Push the slidebuttons (1) at each end of the lampholder (6) and
remove the fluorescent tube (5).

(2) Removal of the ballast unit and lampholder

(a) Find the ballast unit and lampholder (6).

(b) Disconnect the electrical connector (4).

(c) Put blanking caps on the disconnected electrical connectors.

(d) Remove the screws (3), the washers (2) and the ballast unit and
lampholder (6) from the mounting.


R

EFF :

001-012, 014-099,  33-24-11

Page 402
May 01/06
 
IAC 
Ballast Unit and Lampholder 3LQ
Figure 401/TASK 33-24-11-991-001


R

EFF :

001-012, 014-099,  33-24-11

Page 403
May 01/06
 
IAC 
TASK 33-24-11-400-001

Installation of the Ballast Unit and Lampholder 3LQ

WARNING : MAKE SURE THAT YOU INSTALL THE BALLAST UNIT AND THE WIRING CORRECTLY.
_______
THIS WILL PREVENT DAMAGE TO THE WIRING AND ALL DANGER OF ELECTRICAL
SHOCK.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
33-24-11-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-24-11-865-064

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAV LIGHT 1LQ C01


R

EFF :

001-012, 014-099,  33-24-11

Page 404
May 01/06
 
IAC 
4. Procedure
_________

(Ref. Fig. 401/TASK 33-24-11-991-001)

Subtask 33-24-11-420-050

A. Installation of the Ballast Unit with Lampholder and the Tube

WARNING : MAKE SURE THAT YOU INSTALL THE BALLAST UNIT AND THE WIRING
_______
CORRECTLY. THIS WILL PREVENT DAMAGE TO THE WIRING AND ALL
DANGER OF ELECTRICAL SHOCK.

(1) Installation of the ballast unit and lampholder

(a) Do an inspection of the component interface and/or the adjacent


area.

(b) Clean the component interface and/or the adjacent area.

(c) Install the ballast unit and lampholder (6) to the mounting with
the washers (2) and the screws (3).

(d) Remove the blanking caps.

(e) Connect the electrical connector (4).

(2) Installation of the tube

(a) Install the fluorescent tube (5).

(b) Install the upper service cabinet door (11) with the washers (10)
and the screws (9).

(c) Close the lower service cabinet door (8).

Subtask 33-24-11-861-050

B. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-24-11-865-052

C. Remove the safty clip(s) and the tag(s) and close this(these) circuit
breakers(s):
1LQ.


R

EFF :

001-012, 014-099,  33-24-11

Page 405
May 01/06
 
IAC 
Subtask 33-24-11-710-051

D. Test of the Ballast Unit and The Lampholder 3LQ.

(1) On the Forward Attendant Panel (FAP) 120RH push the membrane switch
MAIN ON.

(2) On the FAP 120RH push the POWER LAV membrane switch to on.

(3) Make sure that the lavatory light 3LQ comes on.

5. Close-up
________

Subtask 33-24-11-860-050

A. Put the aircraft back to the serviceable condition.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) On the FAP 120RH push the membrane switch MAIN OFF.

Subtask 33-24-11-862-054

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).


R

EFF :

001-012, 014-099,  33-24-11

Page 406
May 01/06
 
IAC 
TASK 33-24-11-000-002

Removal of the Ballast Unit and Lampholder 4LQ

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-24-11-991-002 Fig. 402

3. __________
Job Set-up

Subtask 33-24-11-865-054

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAV LIGHT 1LQ C01

Subtask 33-24-11-010-067

B. Open the lavatory door.


R

EFF :

001-012, 014-099,  33-24-11

Page 407
May 01/06
 
IAC 
4. Procedure
_________

(Ref. Fig. 402/TASK 33-24-11-991-002)

Subtask 33-24-11-020-053

A. Removal of the Ballast Unit with Lampholder and the Tube

(1) Removal of the tube

(a) Lift the handle (7) to release the latch.

(b) Open the service cabinet door (8).

(c) Push the slidebuttons (1) at each end of the lampholder (6) and
remove the fluorescent tube (5).

(2) Removal of the ballast unit and lampholder

(a) Find the ballast unit and lampholder (6).

(b) Disconnect the electrical connector (4).

(c) Put blanking caps on the disconnected electrical connectors.

(d) Remove the screws (3), the washers (2) and the ballast unit and
lampholder (6) from the mounting.


R

EFF :

001-012, 014-099,  33-24-11

Page 408
May 01/06
 
IAC 
Ballast Unit and Lampholder 4LQ
Figure 402/TASK 33-24-11-991-002


R

EFF :

001-012, 014-099,  33-24-11

Page 409
May 01/06
 
IAC 
TASK 33-24-11-400-002

Installation of the Ballast Unit and Lampholder 4LQ

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
33-24-11-991-002 Fig. 402

3. __________
Job Set-up

Subtask 33-24-11-865-065

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAV LIGHT 1LQ C01


R

EFF :

001-012, 014-099,  33-24-11

Page 410
May 01/06
 
IAC 
4. Procedure
_________

(Ref. Fig. 402/TASK 33-24-11-991-002)

Subtask 33-24-11-420-054

A. Installation of the Ballast Unit with Lampholder and the Tube

(1) Installation of the ballast unit and lampholder

(a) Clean the component interface and/or the adjacent area.

(b) Do an inspection of the component interface and/or the adjacent


area.

(c) Install the ballast unit and lampholder (6) to the mounting with
the washers (2) and the screws (3).

(d) Remove the blanking caps.

(e) Connect the electrical connector (4).

(2) Installation of the tube

(a) Install the fluorescent tube (5).

(3) Close the service cabinet door (8).

Subtask 33-24-11-861-051

B. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-24-11-865-058

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LQ.

Subtask 33-24-11-710-052

D. Test of the Ballast Unit and The Lampholder 4LQ.

(1) On the Forward Attendant Panel (FAP) 120RH push the membrane switch
MAIN ON.

(2) On the FAP 120RH push the membrane switch POWER LAV to on.


R

EFF :

001-012, 014-099,  33-24-11

Page 411
May 01/06
 
IAC 
(3) Make sure that the lavatory light 4LQ comes on .

5. Close-up
________

Subtask 33-24-11-860-051

A. Put the aircraft back to the serviceable condition.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) On the FAP 120RH push the membrane switch MAIN OFF.

Subtask 33-24-11-862-050

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).


R

EFF :

001-012, 014-099,  33-24-11

Page 412
May 01/06
 
IAC 
TASK 33-24-11-000-004

Removal of the Ballast Unit and Lampholder 6LQ

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-24-11-991-004 Fig. 403

3. __________
Job Set-up

Subtask 33-24-11-865-056

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAV LIGHT 1LQ C01

Subtask 33-24-11-010-068

B. Open the lavatory door.


R

EFF :

001-012, 014-099,  33-24-11

Page 413
May 01/06
 
IAC 
4. Procedure
_________

(Ref. Fig. 403/TASK 33-24-11-991-004)

Subtask 33-24-11-020-055

A. Removal of the Ballast Unit with Lampholder and the Tube

(1) Removal of the tube

(a) Lift the handle (7) to release the latch.

(b) Open the service cabinet door (8).

(c) Push the slidebuttons (1) at each end of the lampholder (6) and
remove the flourescent tube (5).

(2) Removal of the ballast unit and lampholder

(a) Find the ballast unit and lampholder (6).

(b) Disconnect the electrical connector (4).

(c) Put blanking caps on the disconnected electrical connectors.

(d) Remove the screws (3), the washers (2) and the ballast unit and
lampholder (6) from the mounting.


R

EFF :

001-012, 014-099,  33-24-11

Page 414
May 01/06
 
IAC 
Ballast Unit and Lampholder 6LQ
Figure 403/TASK 33-24-11-991-004


R

EFF :

001-012, 014-099,  33-24-11

Page 415
May 01/06
 
IAC 
TASK 33-24-11-400-004

Installation of the Ballast Unit and Lampholder 6LQ

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
33-24-11-991-004 Fig. 403

3. __________
Job Set-up

Subtask 33-24-11-865-067

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAV LIGHT 1LQ C01


R

EFF :

001-012, 014-099,  33-24-11

Page 416
May 01/06
 
IAC 
4. Procedure
_________

(Ref. Fig. 403/TASK 33-24-11-991-004)

Subtask 33-24-11-420-056

A. Installation of the Ballast Unit with Lampholder and the Tube

(1) Installation of the ballast unit and lampholder

(a) Clean the component interface and/or the adjacent area.

(b) Do an inspection of the component interface and/or the adjacent


area.

(c) Install the ballast unit and lampholder (6) to the mounting with
the washers (2) and the screws (3).

(d) Remove the blanking caps.

(e) Connect the electrical connector (4).

(2) Installation of the tube

(a) Install the flourescent tube (5).

(b) Close the service cabinet door (8).

Subtask 33-24-11-861-053

B. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-24-11-865-060

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LQ.

Subtask 33-24-11-710-054

D. Test of the Ballast Unit and The Lampholder 6LQ.

(1) On the Forward Attendant Panel (FAP) 120RH push the membrane switch
MAIN ON.

(2) On the FAP 120RH push the membrane switch POWER LAV to on.


R

EFF :

001-012, 014-099,  33-24-11

Page 417
May 01/06
 
IAC 
(3) Make sure that the lavatory light 6LQ comes on.

5. Close-up
________

Subtask 33-24-11-860-053

A. Put the aircraft back to the serviceable condition.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) On the FAP 120RH push the membrane switch MAIN OFF.

Subtask 33-24-11-862-052

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).


R

EFF :

001-012, 014-099,  33-24-11

Page 418
May 01/06
 
IAC 
**ON A/C 101-199, 901-999,

TASK 33-24-11-000-006

Removal of the Ballast Unit and Lampholder

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 101-199,

33-24-11-991-006-A Fig. 404

R **ON A/C 901-999,

33-24-11-991-006 Fig. 404A



EFF :

101-199, 901-999,  33-24-11

Page 419
Aug 01/07
 
IAC 
**ON A/C 101-199, 901-999,

3. __________
Job Set-up

Subtask 33-24-11-865-062

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LIGHT - LAV 1LQ J01

Subtask 33-24-11-010-065

B. Open the lavatory door.

4. Procedure
_________

**ON A/C 101-199,

(Ref. Fig. 404/TASK 33-24-11-991-006-A)

R **ON A/C 901-999,

(Ref. Fig. 404A/TASK 33-24-11-991-006)

**ON A/C 101-199, 901-999,

Subtask 33-24-11-020-057

A. Removal of the Ballast Unit with Lampholder and the Fluorescent Tube

(1) Removal of the fluorescent tube:

(a) Lift the handle (12) to release the latch.

(b) Open the service cabinet door (13).

R (c) Push the slidebuttons (6) at each end of the ballast unit and
R lampholder (5) and remove the fluorescent tube (7).



EFF :

101-199, 901-999,  33-24-11

Page 420
Aug 01/07
 
IAC 
R Ballast Unit and Lampholder
R Figure 404/TASK 33-24-11-991-006-A


R

EFF :

101-199,  33-24-11

Page 421
May 01/07
 
IAC 
Ballast Unit and Lampholder
Figure 404A/TASK 33-24-11-991-006


R

EFF :

901-999,  33-24-11

Page 422
Aug 01/07
 
IAC 
(2) Removal of the ballast unit and lampholder:

(a) Remove the screws (1), the washers (2) and the cover (3).

(b) Release the quick release fasteners (9) and remove the
fluorescent lamp cover (8).

(c) Disconnect the electrical connector (4).

(d) Put blanking caps on the disconnected electrical connectors.

(e) Remove the screws (11), the washers (10) and the ballast unit and
the lampholder (5) from the lavatory structure.



EFF :

101-199, 901-999,  33-24-11

Page 423
May 01/07
R  
IAC 
TASK 33-24-11-400-006

Installation of the Ballast Unit and Lampholder

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

**ON A/C 101-199,

33-24-11-991-006-A Fig. 404

R **ON A/C 901-999,

33-24-11-991-006 Fig. 404A



EFF :

101-199, 901-999,  33-24-11

Page 424
Aug 01/07
 
IAC 
**ON A/C 101-199, 901-999,

3. __________
Job Set-up

Subtask 33-24-11-865-069

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LIGHT - LAV 1LQ J01

4. Procedure
_________

**ON A/C 101-199,

(Ref. Fig. 404/TASK 33-24-11-991-006-A)

R **ON A/C 901-999,

(Ref. Fig. 404A/TASK 33-24-11-991-006)

**ON A/C 101-199, 901-999,

WARNING : MAKE SURE THAT YOU INSTALL THE BALLAST UNIT AND THE WIRING
_______
CORRECTLY. THIS WILL PREVENT DAMAGE TO THE WIRING AND ALL DANGER
OF ELECTRICAL SHOCK.

Subtask 33-24-11-420-059

A. Installation of the Ballast Unit with Lampholder and the Fluorescent Tube

(1) Installation of the ballast unit with lampholder:

(a) Clean the component interface and/or the adjacent area.

(b) Do an inspection of the component interface and/or the adjacent


area.

(c) Install the ballast unit and lampholder (5) on the lavatory
structure with the washers (10) and the screws (11).



EFF :

101-199, 901-999,  33-24-11

Page 425
Aug 01/07
 
IAC 
(d) Remove the blanking caps.

(e) Connect the electrical connector (4).

(f) Install the fluorescent lamp cover (8) with the quick release
fasteners (9).

(g) Install the cover (3) with the screws (1) and the washers (2).

(2) Installation of the fluorescent tube:

(a) Insert fluorescent tube (7) between the slidebuttons (6) at each
R end of the ballast unit and lampholder (5).

(b) Close the service cabinet door (13) and make sure the handle (12)
engages.

Subtask 33-24-11-861-055

B. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-24-11-865-063

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breakers:
1LQ.
R

Subtask 33-24-11-710-056-A

D. Test of the Ballast Unit and the Lampholder.

(1) On the Flight Attendant Panel (FAP) 120RH push the LIGHT MAIN ON/OFF
pushbutton.

(2) On the FAP 120RH push the LAV MAINT pushbutton.

(3) Make sure that the lavatory light comes on.


R



EFF :

101-199, 901-999,  33-24-11

Page 426
Aug 01/07
 
IAC 
5. Close-up
________

Subtask 33-24-11-860-055

A. Aircraft Maintenance Configuration

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) On the FAP 120RH push the membrane switch MAIN OFF.

Subtask 33-24-11-862-055

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

101-199, 901-999,  33-24-11

Page 427
Aug 01/07
R  
IAC 
HALOGEN LAMP WITH LAMPHOLDER - REMOVAL/INSTALLATION
___________________________________________________

TASK 33-24-12-000-002

Removal of the Mirror Lavatory Light

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-51-14-000-006 Removal of the Auxiliary/Mirror Lavatory Light

3. __________
Job Set-up

Subtask 33-24-12-860-050

A. There is no special job set-up for this task.

4. Procedure
_________

Subtask 33-24-12-020-051

A. Remove the mirror lavatory light (Ref. TASK 33-51-14-000-006).


R

EFF :

101-199, 901-999,  33-24-12

Page 401
Feb 01/07
 
IAC 
TASK 33-24-12-400-002

Installation of the Mirror Lavatory Light

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-51-14-400-006 Installation of the Auxiliary/Mirror Lavatory Light

3. __________
Job Set-up

Subtask 33-24-12-860-051

A. There is no special job set-up for this task.

4. Procedure
_________

Subtask 33-24-12-420-051

A. Install the mirror lavatory light (Ref. TASK 33-51-14-400-006).


R

EFF :

101-199, 901-999,  33-24-12

Page 402
Feb 01/07
 
IAC 
PASSENGER READING LIGHTS - DESCRIPTION AND OPERATION
____________________________________________________

1. _______
General
Passenger reading lights supply high intensity light to each passenger seat.
Each light has an ON/OFF switch.

2. __________________
Component Location

R **ON A/C 001-012, 014-099,

R
R (Ref. Fig. 001, 002)

-------------------------------------------------------------------------------
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
7LW RELAY 2000VU 223 33-25-00
8LW RELAY 2000VU 223 33-25-00
120RH ATTENDANT PANEL-FORWARD 221 831 23-73-00
501RH MEMBRANE SWITCH 200 23-73-00
502RH MEMBRANE SWITCH 200 23-73-00
503RH MEMBRANE SWITCH 200 23-73-00
511RH POWER UNIT 200 23-73-00
512RH POWER UNIT 200 23-73-00
513RH POWER UNIT 200 23-73-00
514RH POWER UNIT 200 23-73-00
521RH READING LIGHT 200 23-73-64
522RH READING LIGHT 200 23-73-64
523RH READING LIGHT 200 23-73-64
524RH READING LIGHT 200 23-73-64
525RH READING LIGHT 200 23-73-64
526RH READING LIGHT 200 23-73-64
2040VUJ COMBI PANEL 200 25-25-11
2041VUJ COMBI PANEL 200 25-25-11
2040VUK COMBI PANEL 200 25-25-11
2041VUK COMBI PANEL 200 25-25-11
2040VUE COMBI PANEL 200 25-25-11
2041VUE COMBI PANEL 200 25-25-11
2040VUF COMBI PANEL 200 25-25-11
2041VUF COMBI PANEL 200 25-25-11
2040VUG COMBI PANEL 200 25-25-11
2041VUG COMBI PANEL 200 25-25-11
2040VUR COMBI PANEL 200 25-25-11
2041VUR COMBI PANEL 200 25-25-11



EFF :

ALL  33-25-00

Page 1
Aug 01/07
 
IAC 
Passenger Reading Lights - Schematic
Figure 001 (SHEET 1)


R

EFF :

001-012, 014-099,  33-25-00

Page 2
May 01/06
 
IAC 
Passenger Reading Lights - Schematic
Figure 001 (SHEET 2)


R

EFF :

001-012, 014-099,  33-25-00

Page 3
May 01/06
 
IAC 
R Passenger Reading Lights - Schematic
R Figure 001A


R

EFF :

101-199,  33-25-00

Page 4
Aug 01/07
 
IAC 
Passenger Reading Lights - Schematic
Figure 001B


R

EFF :

901-901,  33-25-00

Page 5
May 01/07
 
IAC 
R Passenger Reading Lights - Schematic
R Figure 001C (SHEET 1)


R

EFF :

902-999,  33-25-00

Page 6
Aug 01/07
 
IAC 
R Passenger Reading Lights - Schematic
R Figure 001C (SHEET 2)


R

EFF :

902-999,  33-25-00

Page 7
Aug 01/07
 
IAC 
Passenger Reading Lights - Component Location
Figure 002 (SHEET 1)


R

EFF :

001-012, 014-099,  33-25-00

Page 8
Aug 01/07
 
IAC 
Passenger Reading Lights - Component Location
Figure 002 (SHEET 2)


R

EFF :

001-012, 014-099,  33-25-00

Page 9
Aug 01/07
 
IAC 
R **ON A/C 101-199,

R (Ref. Fig. 002A)

R -------------------------------------------------------------------------------
R FIN | FUNCTIONAL DESIGNATION | PANEL | ZONE | ACCESS | ATA
R | | | | DOOR | REF.
R -------------------------------------------------------------------------------
R 120RH ATTENDANT PANEL-FLIGHT 221 831 23-73-00
R 651RH PSU LH/RH 200 25-25-11
R 652RH PSU LH/RH 200 25-25-11

**ON A/C 901-901,

R (Ref. Fig. 002B)

-------------------------------------------------------------------------------
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
120RH ATTENDANT PANEL-FLIGHT 221 831 23-73-00
602RH StA-PISA 200 23-73-00
603RH LED READING LIGHT 200 23-73-64
604RH LED READING LIGHT 200 23-73-64
605RH LED READING LIGHT 200 23-73-64
611RH PSU FWD EXIT 200 25-25-11
612RH PSU AFT EXIT 200 25-25-11
621RH PSU LH/RH 200 25-25-11
622RH PSU LH/RH 200 25-25-11

R **ON A/C 902-999,

R (Ref. Fig. 002C)

R -------------------------------------------------------------------------------
R FIN | FUNCTIONAL DESIGNATION | PANEL | ZONE | ACCESS | ATA
R | | | | DOOR | REF.
R -------------------------------------------------------------------------------
R 120RH ATTENDANT PANEL-FLIGHT 221 831 23-73-00
R 651RH PSU LH/RH 200 25-25-11
R 652RH PSU LH/RH 200 25-25-11
R 653RH PSU LH/RH 200 25-25-11


R

EFF :

101-199, 901-999,  33-25-00

Page 10
Aug 01/07
 
IAC 
**ON A/C ALL

3. __________________
System Description

R **ON A/C 001-012, 014-099,

The reading lights are installed in the combi-panels. The combi-panels are
fitted in the Passenger Service Unit (PSU) channel above the passenger
seats. The combi-panel fitted must agree with the number of seats in a row.
The reading light configurations are listed below:
- two reading lights are installed in the combi-panels 2040/2041VUJ and
2040/2041VUK with the middle position blanked off,
- two reading lights are installed in the combi-panels 2040/2041VUE with the
inboard position blanked off,
- three reading lights are installed in the combi-panels 2040/2041VUF,
2040/2041VUG and 2040/2041VUR.

R **ON A/C 101-199,

R The passenger reading lights are installed in the Passenger Service Units
R (PSUs). The PSUs are located in the PSU channel above the passenger seats.
R The number of PSUs on each side of the cabin must agree with the number of
R seat rows. There are:
R - Three reading lights in each of the PSUs 651RH
R - Two or three reading lights in each of the PSUs 652RH
R - One reading light and an attendant loudspeaker in each of the PSUs 652RH.

**ON A/C 901-901,

The reading lights are installed in the Passenger Service Units (PSUs). The
PSUs are installed in the PSU channel above the passenger seats. The number
of PSUs on each side of the cabin must agree with the number of seat rows.
Three reading lights are installed in each of the PSUs 621RH.
Two or three reading lights are installed in each of the PSUs 622RH.

R **ON A/C 902-999,

R The passenger reading lights are installed in the Passenger Service Units
R (PSUs). The PSUs are located in the PSU channel above the passenger seats.
R The number of PSUs on each side of the cabin must agree with the number of
R seat rows. There are:
R - Three reading lights in each of the PSUs 651RH and 653RH


R

EFF :

ALL  33-25-00

Page 11
Aug 01/07
 
IAC 
R Passenger Reading Lights - Component Location
R Figure 002A (SHEET 1)


R

EFF :

101-199,  33-25-00

Page 12
Aug 01/07
 
IAC 
R Passenger Reading Lights - Component Location
R Figure 002A (SHEET 2)


R

EFF :

101-199,  33-25-00

Page 13
Aug 01/07
 
IAC 
Passenger Reading Lights - Component Location
R Figure 002B (SHEET 1)



EFF :

901-901,  33-25-00

Page 14
Aug 01/07
 
IAC 
Passenger Reading Lights - Component Location
R Figure 002B (SHEET 2)



EFF :

901-901,  33-25-00

Page 15
Aug 01/07
 
IAC 
R Passenger Reading Lights - Component Location
R Figure 002C (SHEET 1)



EFF :

902-999,  33-25-00

Page 16
Aug 01/07
 
IAC 
R Passenger Reading Lights - Component Location
R Figure 002C (SHEET 2)



EFF :

902-999,  33-25-00

Page 17
Aug 01/07
 
IAC 
R - Two or three reading lights in each of the PSUs 652RH.

**ON A/C ALL

4. ____________
Power Supply

**ON A/C 001-012, 014-099,

115VAC is supplied to the reading lights from the busbars 110XP and 210XP.
This is controlled through the circuit breakers 1LW thru 6LW and the relays
7LW and 8LW.
The power units 511RH thru 514RH change the 115VAC to 6VAC for the light
operation. A fuse in each line gives protection for the transformer and the
related Printed Circuit Board (PCB). A membrane switch POWER READ on the
Forward Attendant Panel (FAP) 120RH controls the power supply for the
reading lights.
R

R **ON A/C 101-199, 901-999,

115VAC is supplied to the reading lights from the busbars 110XP and 210XP.
This is controlled through the circuit breakers 1LW thru 6LW and the relays
7LW and 8LW.
The Stand Alone - Passenger Interface and Supply Adapter (StA-PISA) changes
the 115VAC to 28VDC for the operation of the light. A fuse in each line
gives protection for the transformer and the related Printed Circuit Board
(PCB). The Main ON/OFF touchbutton on the LIGHT page at the Flight
Attendant Panel (FAP) 120RH controls the power supply for the reading
lights.

**ON A/C ALL

5. Operation
_________



EFF :

ALL  33-25-00

Page 18
Aug 01/07
 
IAC 
**ON A/C 001-012, 014-099,

(Ref. Fig. 001)

A. Component Description

(1) When the POWER READ membrane switch on the FAP 120RH is pushed, the
power units 511RH thru 514RH are activated. The coils of the relays
7LW and 8LW in the panel 2000VU are energized. This closes the
contacts of the relays and 115VAC is supplied to the power units.

(2) When the reading-light membrane switches 501RH thru 503RH are pushed,
a ground pulse is supplied to the voltage control circuit. This
completes the primary circuit of the step-down transformer. The
transformer changes the 115VAC down to 6VAC which causes the lights
to come on.

(3) A test of the reading lights, the work lights and the PCB circuits is
made by the related BITE test on the Programming and Test Panel (PTP)
110RH. In this test all reading lights and work lights come on for
approximately 3 s and then go off. After the test the PTP 110RH shows
the status of the reading lights, the work lights and the PCBs.
R

R **ON A/C 101-199, 901-999,

R **ON A/C 101-199,

R (Ref. Fig. 001A)

R **ON A/C 901-901,

(Ref. Fig. 001B)

R **ON A/C 902-999,

R (Ref. Fig. 001C)



EFF :

ALL  33-25-00

Page 19
Aug 01/07
 
IAC 
R **ON A/C 101-199, 901-999,

A. Component Description

R (1) The cabin reading light-system gives lighting to each passenger seat.
R The passenger reading light can be controlled with a button on the
R Passenger Service Unit (PSU) or through the Passenger Service System
R (PSS)/Cabin Intercommunication Data-System (CIDS) from the Power
R Control Unit (PCU).
The passenger reading lights are supplied by Passenger Interface and
Supply Adapters (PISA). These units change the voltage from 115VAC to
the necessary reading light supply voltage of 28VDC.
The PISA gives the interface to CIDS for test, control functions and
internal tests to find reading light malfunctions (Ref. 23-73-00).

(2) Not Applicable

(3) Not Applicable



EFF :

101-199, 901-999,  33-25-00

Page 20
Aug 01/07
 
IAC 
PASSENGER READING LIGHTS - ADJUSTMENT/TEST
__________________________________________

TASK 33-25-00-710-001

Operational test of the Passenger Reading Light System

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

23-73-00-861-001 Energize the Cabin Intercommunication Data System


(CIDS)
23-73-00-862-001 De-energize the Cabin Intercommunication Data System
(CIDS)
R 24-42-00-861-001 Energize the Ground Service Network from the External
R Power
R 24-42-00-862-001 De-energize the Ground Service Network Supplied from
R the External Power
33-27-00-710-001 Operational Test of the Cabin Attendant Work-Light
33-27-00-740-001 Bite Test of the Cabin Attendant Work-Light through
MCDU

3. __________
Job Set-up

Subtask 33-25-00-860-050

A. Aircraft Maintenance Configuration

R (1) Energize the ground service network


R (Ref. TASK 24-42-00-861-001).
R

R (2) Energize the Cabin Intercommunication Data-System (CIDS)


R (Ref. TASK 23-73-00-861-001).



EFF :

ALL  33-25-00

Page 501
Feb 01/08
 
IAC 
**ON A/C 001-012, 014-099,

Subtask 33-25-00-865-050

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU PASSENGER READING LIGHT 1LW G2
2000VU PASSENGER READING LIGHT 2LW G3
2000VU PASSENGER READING LIGHT 3LW G4
2000VU PASSENGER READING LIGHT 4LW G5
2000VU PASSENGER READING LIGHT 5LW G6
2000VU PASSENGER READING LIGHT 6LW G7

R **ON A/C 101-199, 901-999,

Subtask 33-25-00-865-050-A

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU PASSENGER READING LIGHT 1LW G1
2000VU PASSENGER READING LIGHT 2LW G2
2000VU PASSENGER READING LIGHT 3LW G3
2000VU PASSENGER READING LIGHT 4LW G4
2000VU PASSENGER READING LIGHT 5LW G5
2000VU PASSENGER READING LIGHT 6LW G6



EFF :

ALL  33-25-00

Page 502
Feb 01/07
 
IAC 
R **ON A/C ALL

4. Procedure
_________

R **ON A/C 001-012, 014-099,

Subtask 33-25-00-710-050

A. Operational test of the Passenger Reading Light System

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the FWD Attendant Panel (FAP) On the FAP 120RH:


120RH:
- push the POWER READ membrane - the integral light of the POWER READ
switch. membrane switch comes on.

2. In the cabin: In the cabin:


- push all reading light - all the reading lights come on.
pushbutton-switches.

3. On the FAP 120RH: In the cabin:


- push to reset the POWER READ - all the reading lights go off.
membrane switch.
On the FAP 120RH:
- the integral light of the POWER READ
membrane switch goes off.

- in less than 10 s push the - the integral light of the POWER READ
POWER READ membrane switch membrane switch comes on.
again.
In the cabin:
- all the reading lights come on.

- push to reset the POWER READ - all the reading lights go off.
membrane switch.
On the FAP 120RH:
- the integral light of the POWER READ
membrane switch goes off.



EFF :

ALL  33-25-00

Page 503
May 01/06
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- after more than 10 s push the - the integral light of the POWER READ
POWER READ membrane switch membrane switch comes on.
again.

4. In the cabin: In the cabin:


- push all the reading light - all the reading lights come on.
pushbutton-switches.

5. On the FAP 120RH: In the cabin:


- push the MAIN OFF membrane - all the reading lights go off.
switch.

NOTE : The general illumination goes off if it is on.


____

On the FAP 120RH:


- the integral light of the POWER READ
membrane switch goes off.

Subtask 33-25-00-740-050

B. BITE test of the Passenger Reading Light System through PTP

(1) Do the BITE test of the passenger reading lights and the cabin
attendant work-lights on the programming and test panel 110RH
(Ref. TASK 33-27-00-710-001).


R

EFF :

001-012, 014-099,  33-25-00

Page 504
May 01/06
 
IAC 
R **ON A/C 101-199, 901-999,

Subtask 33-25-00-710-050-A

A. Operational test of the Passenger Reading Light-System

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the Flight Attendant Panel On the FAP 120RH:


(FAP) 120RH:

- Push the LIGHTS MAIN ON/OFF - The LIGHTS MAIN ON/OFF indication on
membrane switch. the membrane switch comes on.

- Set the LIGHT page. - All possible cabin lighting zones are
shown.

In the cabin: In the cabin:

- Push all pushbuttons of the - All the reading lights come on.
reading lights.

On the FAP 120RH: On the FAP 120RH:

- Push the R/L Reset pushbutton. - The R/L Reset indication shows as
long as the pushbutton is pushed.

In the cabin:
- All reading lights go off.

2. On the FAP 120RH: On the FAP 120RH:

- Push the R/L Set pushbutton. - The R/L Set indication shows as long
as the pushbutton is pushed.

In the cabin:
- All reading lights come on.

On the FAP 120RH:

- Push the LIGHTS MAIN ON/OFF - The LIGHTS MAIN ON/OFF indication
membrane switch. light goes off.


R

EFF :

101-199, 901-999,  33-25-00

Page 505
Feb 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
In the cabin:
- All reading lights go off.
- All cabin lighting go off.

Subtask 33-25-00-740-050-A

B. BITE test of the Passenger Reading Light System through MCDU

(1) Do the BITE test of the passenger reading lights and the cabin
attendant work-lights on the Multipurpose Control and Display Unit
(MCDU) 3CA (Ref. TASK 33-27-00-740-001).

**ON A/C ALL

5. Close-up
________

Subtask 33-25-00-862-050

A. Put the aircraft back to the serviceable condition.

(1) De-energize the CIDS


R (Ref. TASK 23-73-00-862-001).

R (2) De-energize the ground service network


R (Ref. TASK 24-42-00-862-001).
R



EFF :

ALL  33-25-00

Page 506
Feb 01/08
 
IAC 
TASK 33-25-00-820-001

Adjustment of the Passenger Reading Lights

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

8PE004363-10 1 ADJUSTING DEVICE


8PE455160-20 1 TOOL-ADJUSTMENT, READING LIGHT
R 8PE455838-00 1 TOOL - ADJUSTMENT, READING LIGHT

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

23-73-00-861-001 Energize the Cabin Intercommunication Data System


(CIDS)
R 23-73-00-862-001 De-energize the Cabin Intercommunication Data System
R (CIDS)
R 24-42-00-861-001 Energize the Ground Service Network from the External
R Power
R 24-42-00-862-001 De-energize the Ground Service Network Supplied from
R the External Power

R **ON A/C 101-199, 902-999,

R 33-25-00-991-001-A Fig. 501

R **ON A/C 901-901,

R 33-25-00-991-001 Fig. 501A



EFF :

ALL  33-25-00

Page 507
Feb 01/08
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-25-00-861-051

R A. Energize the ground service network


R (Ref. TASK 24-42-00-861-001).

**ON A/C 001-012, 014-099,

Subtask 33-25-00-865-051

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU PASSENGER READING LIGHT 1LW G2
2000VU PASSENGER READING LIGHT 2LW G3
2000VU PASSENGER READING LIGHT 3LW G4
2000VU PASSENGER READING LIGHT 4LW G5
2000VU PASSENGER READING LIGHT 5LW G6
2000VU PASSENGER READING LIGHT 6LW G7

**ON A/C 101-199, 901-999,

Subtask 33-25-00-865-051-A

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU PASSENGER READING LIGHT 1LW G1
2000VU PASSENGER READING LIGHT 2LW G2
2000VU PASSENGER READING LIGHT 3LW G3
2000VU PASSENGER READING LIGHT 4LW G4
2000VU PASSENGER READING LIGHT 5LW G5
2000VU PASSENGER READING LIGHT 6LW G6



EFF :

ALL  33-25-00

Page 508
Feb 01/08
 
IAC 
R **ON A/C 001-012, 014-099,

R Subtask 33-25-00-010-050

R C. Get Access

R CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
R THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
R LAMP.
R IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
R LINT-FREE CLOTH.

R (1) Carefully remove the lens from the reading light.

R **ON A/C 901-901,

Subtask 33-25-00-010-050-A

C. Get Access

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.

(1) Carefully remove the LED reading light lens (2) from the related
reading light.

**ON A/C 001-012, 014-099,

Subtask 33-25-00-480-050

D. Install the ADJUSTING DEVICE in the housing of the reading light and turn
it clockwise to lock it.


R

EFF :

001-012, 014-099, 901-901,  33-25-00

Page 509
Feb 01/08
 
IAC 
Subtask 33-25-00-860-051

E. Aircraft Maintenance Configuration

(1) Make sure that the Cabin Intercommunication Data System (CIDS) is
energized (Ref. TASK 23-73-00-861-001).

(2) On the FWD Attendant Panel (FAP) 120RH, push the membrane switches
MAIN ON and POWER READ.

**ON A/C 101-199, 901-999,

Subtask 33-25-00-860-051-A

E. Aircraft Maintenance Configuration

(1) Make sure that the Cabin Intercommunication Data System (CIDS) is
energized (Ref. TASK 23-73-00-861-001).

(2) On the Light page of the Flight Attendant Panel (FAP) 120RH, push the
LIGHT MAIN ON/OFF button to ON.

**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

Subtask 33-25-00-820-050

A. Adjustment of the Passenger Reading Lights

(1) On the combi-panel 2040VU/2041VU, push the related membrane switch of


the reading light.

(2) Make sure that the reading light comes on.

(3) Adjust the reading light beam to the center of the leading edge of
the related seat with the ADJUSTING DEVICE.

NOTE : Do not adjust the angle of the reading light beam more than 20
____
degrees in each direction.



EFF :

ALL  33-25-00

Page 510
Feb 01/08
R  
IAC 
(4) On the combi-panel 2040VU/2041VU, push the related membrane switch of
the reading light.

(5) Make sure that the reading light goes off.

R **ON A/C 101-199, 902-999,

R Subtask 33-25-00-820-050-B

R A. Adjustment of the Passenger LED Reading Light


R (Ref. Fig. 501/TASK 33-25-00-991-001-A)

R NOTE : The procedure for all the reading lights is the same. Only one
____
R procedure is given.

R NOTE : The lens (7) stays on the TOOL - ADJUSTMENT, READING LIGHT (1)
____
R during the adjustment procedure.

R (1) Carefully push the suction end (6) of the TOOL - ADJUSTMENT, READING
R LIGHT (1) onto the lens (7) of the reading light (2).

R (2) Pull the TOOL - ADJUSTMENT, READING LIGHT (1) to remove the lens (7)
R from the reading light (2).

R (3) Push the button of the related reading light to ON.

R (4) Make sure that the reading light comes on.

R (5) Make sure that the related seat is in the vertical position.

R (6) Connect the adjustment end (3) of the TOOL - ADJUSTMENT, READING
R LIGHT (1) to the reading light.

R (7) Lock the TOOL - ADJUSTMENT, READING LIGHT (1) with the small lever
R (4).

R (8) Swivel the TOOL - ADJUSTMENT, READING LIGHT (1) until the light beam
R through the TOOL - ADJUSTMENT, READING LIGHT (1) points to the
R correct direction.

R (9) Unlock the TOOL - ADJUSTMENT, READING LIGHT (1) and remove the TOOL -
R ADJUSTMENT, READING LIGHT (1) from the reading light (2).

R (10) Push the button of the related reading light to OFF.

R (11) Make sure that the reading light goes off.


R

EFF :

001-012, 014-099, 101-199, 902-999,  33-25-00

Page 511
Feb 01/08
 
IAC 
R Adjustment of the Passenger LED Reading Light
R Figure 501/TASK 33-25-00-991-001-A


R

EFF :

101-199, 902-999,  33-25-00

Page 512
Feb 01/08
 
IAC 
R (12) Put the suction end (6) of the TOOL - ADJUSTMENT, READING LIGHT (1)
R with the lens (7) to the reading light (2).

R (13) Push the lens (7) into the correct position until you hear a click.

R (14) Press the pushbutton (5) to release the lens (7).

R **ON A/C 901-901,

Subtask 33-25-00-820-050-A

A. Adjustment of the Passenger LED Reading Light


R (Ref. Fig. 501A/TASK 33-25-00-991-001)

(1) On the Passenger Service Unit (PSU)(1), push the membrane switch of
the related reading light.

(2) Make sure that the reading light comes on.

(3) Open and move the tray table (6) to the open position.

(4) Make sure that the seat (5) is in the vertical position.

(5) Put the TOOL-ADJUSTMENT, READING LIGHT (4) in position on the housing
(3) of the reading light.

(6) Use the TOOL-ADJUSTMENT, READING LIGHT (4) to adjust the reading
light beam (7).

NOTE : Do not adjust the angle of the reading light beam more than 20
____
degrees in each direction.

(7) Remove the TOOL-ADJUSTMENT, READING LIGHT (4).

(8) On the PSU (1), push the membrane switch of the related reading
light.

(9) Make sure that the reading light goes off.



EFF :

101-199, 901-999,  33-25-00

Page 513
Feb 01/08
 
IAC 
Adjustment of the Passenger LED Reading Light
R Figure 501A/TASK 33-25-00-991-001



EFF :

901-901,  33-25-00

Page 514
Feb 01/08
 
IAC 
**ON A/C ALL

5. Close-up
________

**ON A/C 001-012, 014-099,

Subtask 33-25-00-080-050

A. Turn the ADJUSTING DEVICE counterclockwise to release it and remove it


from the reading light.

Subtask 33-25-00-410-050

B. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the lens on the reading light.


R

R **ON A/C 901-901,

Subtask 33-25-00-410-050-A

B. Close Access

(1) Close the tray table (6).

(2) Make sure that the work area is clean and clear of tool(s) and other
items.

(3) Push the LED reading light lens (2) with a slight pressure in the
housing (3) of the reading light.

(4) Make sure that you hear a click.



EFF :

ALL  33-25-00

Page 515
Feb 01/08
 
IAC 
R **ON A/C 001-012, 014-099,

R Subtask 33-25-00-860-052

R C. Put the aircraft back to its initial configuration.

R (1) On the FAP 120RH push the membrane switches MAIN OFF and POWER READ.

R (2) De-energize the CIDS


R (Ref. TASK 23-73-00-862-001).

R (3) De-energize the ground service network


R (Ref. TASK 24-42-00-862-001).

R **ON A/C 101-199, 901-999,

Subtask 33-25-00-860-052-A

C. Put the aircraft back to its initial configuration.

R (1) Make sure that the work area is clean and clear of tool(s) and other
R items.

R (2) Push the LIGHT MAIN ON/OFF button on the LIGHT page of the FAP 120RH
to OFF.

R (3) De-energize the CIDS


R (Ref. TASK 23-73-00-862-001).

R (4) De-energize the ground service network


R (Ref. TASK 24-42-00-862-001).



EFF :

ALL  33-25-00

Page 516
Feb 01/08
 
IAC 
LAVATORY LIGHTED SIGNS - DESCRIPTION AND OPERATION
__________________________________________________

1. _______
General
The lavatory signs are installed near the forward and aft lavatories. They
show the position of the lavatories in the cabin and if the lavatories are
occupied or not.

2. __________________
Component Location

**ON A/C 001-012, 014-099,

(Ref. Fig. 001)

-------------------------------------------------------------------------------
FIN FUNCTIONAL DESIGNATION PANEL ZONE ACCESS ATA
DOOR REF.
-------------------------------------------------------------------------------
2WJ MICROSWITCH 221
3WJ LAVATORY OCCUPIED SIGN 3700VU 220 33-26-23
6WJ ANNUNCIATOR-TOILET OCCUPD 48VU 210 33-26-23
9WJ MICROSWITCH 261
10WJ MICROSWITCH 262
13WJ LAVATORY OCCUPIED SIGN 3701VU 260 33-26-23
14WJ LAVATORY OCCUPIED SIGN 3701VU 260 33-26-23

R **ON A/C 101-199,

R (Ref. Fig. 001A)

R -------------------------------------------------------------------------------
R FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
R | | | | DOOR | REF.
R -------------------------------------------------------------------------------
R 3WJ SIGN-LAVATORY OCCUPIED 3700VU 220 831 33-26-23
R 6WJ ANNUNCIATOR-TOILET/OCCPD 48VU 210 831 33-26-00
R 13WJ SIGN-LAVATORY OCCUPIED 3701VU 260 832 33-26-23
R 14WJ SIGN-LAVATORY OCCUPIED 3701VU 260 832 33-26-23
R 2WJ1 MICROSWITCH 221 831 33-26-11
R 2WJ4 MICROSWITCH 261 832 33-26-11
R 2WJ9 MICROSWITCH 251 842 33-26-11
R 2WJ10 MICROSWITCH 252 832 33-26-11
R 5WJ9 RELAY 251 832 33-26-00
R 8WJ9 RELAY 251 832 33-26-00



EFF :

ALL  33-26-00

Page 1
May 01/07
 
IAC 
Lavatory Lighted Signs - Component Location
Figure 001


R

EFF :

001-012, 014-099,  33-26-00

Page 2
May 01/06
 
IAC 
R Lavatory Lighted Signs - Component Location
Figure 001A



EFF :

101-199,  33-26-00

Page 3
Feb 01/08
 
IAC 
**ON A/C 901-999,

(Ref. Fig. 001B)

-------------------------------------------------------------------------------
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
3WJ SIGN-LAVATORY OCCUPIED 3700VU 220 831 33-26-23
6WJ ANNUNCIATOR-TOILET/OCCPD 48VU 210 831 33-26-00
13WJ SIGN-LAVATORY OCCUPIED 3701VU 260 832 33-26-23
14WJ SIGN-LAVATORY OCCUPIED 3701VU 260 832 33-26-23
2WJ1 MICROSWITCH 221 831 33-26-11
2WJ4 MICROSWITCH 261 832 33-26-11
2WJ5 MICROSWITCH 262 842 33-26-11

**ON A/C ALL

3. __________________
System Description

R A. Occupied Sign of the Forward Lavatory A


R The occupied sign 3WJ shows the position of the forward lavatory A and if
R it is occupied or not. The sign is installed in a position where it is
R easily seen.

**ON A/C 001-012, 014-099,

(Ref. Fig. 002)

**ON A/C 101-199,

(Ref. Fig. 002A)

**ON A/C 901-999,

(Ref. Fig. 002B)



EFF :

ALL  33-26-00

Page 4
Feb 01/08
 
IAC 
Lavatory Lighted Signs - Component Location
Figure 001B


R

EFF :

901-999,  33-26-00

Page 5
Aug 01/07
 
IAC 
INTENTIONALLY BLANK


R



 33-26-00

Page 6
Aug 01/07
 
IAC 
Lavatory Lighted Signs - Schematic
Figure 002


R

EFF :

001-012, 014-099,  33-26-00

Page 7/8
May 01/07
 
IAC 
INTENTIONALLY BLANK


R



 33-26-00

Page 9
May 01/07
 
IAC 
R Lavatory Lighted Signs - Schematic
R Figure 002A (SHEET 1)


R

EFF :

101-199,  33-26-00

Page 10
May 01/07
 
IAC 
R Lavatory Lighted Signs - Schematic
R Figure 002A (SHEET 2)


R

EFF :

101-199,  33-26-00

Page 11
May 01/07
 
IAC 
Lavatory Lighted Signs - Schematic
Figure 002B (SHEET 1)


R

EFF :

901-999,  33-26-00

Page 12
Aug 01/07
 
IAC 
Lavatory Lighted Signs - Schematic
Figure 002B (SHEET 2)


R

EFF :

901-999,  33-26-00

Page 13
Aug 01/07
 
IAC 
**ON A/C ALL

(1) The 28VDC normal busbar 208PP energizes the sign through the circuit
breaker 1WJ and the microswitch of the related lavatory. The
R microswitch is installed in the door frame of the lavatory A.

R (2) If the door of the lavatory A unlocked, the electrical supply flows
R through the related microswitch to the FREE terminal of the sign. The
R sign pictogram/legend comes on with a green color to show that the
R lavatory A is not occupied.

(3) When the door is closed and locked, the contacts of the related
R microswitch change over. This moves the electrical supply from the
R FREE terminal to the ENGAGED terminal. Thus, the sign
R pictogram/legend comes on with a red color to show that the lavatory
R A is occupied. At the same time the relay 18LP energizes. The
R annunciator 6WJ in the cockpit comes on to show the flight crew that
R the forward lavatory A is occupied.

**ON A/C 001-012, 014-099,

B. Rear Lavatory Occupied-Signs


(Ref. Fig. 002)
The rear lavatory occupied-signs 13WJ and 14WJ show the positions of the
two rear lavatories. They also show if the lavatories are occupied or not
occupied. The signs are installed in a position where they can be easily
seen.

(1) The 28VDC busbar 208PP energizes the signs through the circuit
breaker 11WJ and the related microswitches of the lavatories. One
microswitch is installed in the door frame of each rear lavatory.

(2) With the lavatory doors unlocked, the electrical supply flows through
the lavatory microswitches to the FREE terminal of each sign. The
sign pictogram/legends come on green to show that the lavatories are
not occupied.

(3) When the lavatory doors are closed and locked, the contacts of the
microswitches change over and remove the electrical supply from the
FREE terminal to the ENGAGED terminal of the related sign. The sign
pictogram/legends change to red to show that the related lavatory is
occupied.



EFF :

ALL  33-26-00

Page 14
Feb 01/08
 
IAC 
**ON A/C 101-199,

B. Rear Lavatory Occupied-Signs


(Ref. Fig. 002A)

(1) The rear lavatory occupied-sign 13WJ shows the positions of the two
rear lavatories D and L on the left side. It also shows if the two
lavatories are occupied or not occupied. The sign is installed in a
position where it can be seen easily.

(a) The 28VDC normal busbar 208PP energizes the sign 13WJ through the
circuit breaker 11WJ and the relay 1. The door microswitches of
the lavatories D and L and the relay 2 energize the relay 1.
The two relays are installed in the lavatory L. One microswitch
is installed in the door frame of each of the lavatories D and L.

(b) With one or the two doors of these lavatories unlocked, the
relays cause the electrical supply to energize the FREE terminal
of the sign 13WJ. The sign pictogram/legend comes on green to
show that at least one of these lavatories is not occupied.

(c) When the door of each of the lavatories D and L is closed and
locked, the electrical supply energizes the two relays. The relay
1 removes the electrical supply from the FREE terminal of the
sign 13WJ and supplies it to the ENGAGED terminal. The sign
pictogram/legend changes to red and shows that the two lavatories
are occupied.

(2) The rear lavatory occupied-sign 14WJ shows the position of the rear
lavatory M on the right side. It also shows if this lavatory is
occupied or not occupied. The sign is installed in a position where
it can be seen easily.

(a) The 28VDC normal busbar 208PP energizes the sign 14WJ through the
circuit breaker 11WJ and the microswitch of the lavatory M.
The microswitch is installed in the door frame of this lavatory.

(b) With the door of the lavatory M unlocked, electrical supply flows
to the FREE terminal of the sign 14WJ. The sign pictogram/legend
comes on green to show that this lavatory is not occupied.

(c) When the door of the lavatory M is closed and locked, the
microswitch contacts change over. The microswitch removes the
electrical supply from the FREE terminal to the ENGAGED terminal
of the sign 14WJ. The sign pictogram/legend changes to red and
shows that this lavatory is occupied.


R

EFF :

101-199,  33-26-00

Page 15
Aug 01/07
 
IAC 
(3) Not Applicable

R **ON A/C 901-999,

B. Rear Lavatory Occupied-Signs


(Ref. Fig. 002B)
The rear lavatory occupied-signs 13WJ and 14WJ show the positions of the
two rear lavatories. They also show if the lavatories are occupied or not
occupied. The signs are installed in a position where they can be easily
seen.

(1) The 28VDC busbar 208PP energizes the signs through the circuit
breaker 11WJ and the related microswitches of the lavatories D and E.
The microswitch 2WJ4 is installed in the door frame of the lavatory D
and the microswitch 2WJ5 is installed in the door frame of the
lavatory E.

(2) With the lavatory doors unlocked, the electrical supply flows through
the lavatory microswitches to the FREE terminal of each sign. The
sign pictogram/legends come on green to show that the lavatories are
not occupied.

(3) When the lavatory doors are closed and locked, the contacts of the
microswitches change over and remove the electrical supply from the
FREE terminal to the ENGAGED terminal of the related sign. The sign
pictogram/legends change to red to show that the related lavatory is
occupied.
R



EFF :

101-199, 901-999,  33-26-00

Page 16
Aug 01/07
 
IAC 
LAVATORY LIGHTED SIGNS - ADJUSTMENT/TEST
________________________________________

TASK 33-26-00-710-001

Operational Test of the Lavatory Lighted Signs WJ

1. __________________
Reason for the Job

To make sure that the lavatory lighted signs operate correctly.

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

**ON A/C 001-012, 014-019,

Subtask 33-26-00-865-050

A. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAVATORY FORWARD OCCUPIED 1WJ C06
2001VU LAVATORY AFT OCCUPIED 11WJ E07

**ON A/C 020-099,

Subtask 33-26-00-865-050-A

A. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAVATORY FWD & MID OCCUPIED 1WJ C06
2001VU LAVATORY AFT OCCUPIED 11WJ C07



EFF :

ALL  33-26-00

Page 501
Feb 01/07
R  
IAC 
R **ON A/C 101-199,

R Subtask 33-26-00-865-050-C

R A. Make sure that this(these) circuit breaker(s) is(are) closed:

R -------------------------------------------------------------------------------
R PANEL SERVICE IDENT. LOCATION
R -------------------------------------------------------------------------------
R 2000VU LAV FWD & MID - OCCUPIED 1WJ F01
R 2001VU LAVATORY AFT OCCUPIED 11WJ B04

R **ON A/C 901-999,

Subtask 33-26-00-865-050-B

A. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAVATORY FWD & MID OCCUPIED 1WJ C06
2001VU LAVATORY AFT OCCUPIED 11WJ E07

**ON A/C ALL

Subtask 33-26-00-865-051

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/ANN LT SPLY/XFMR/BUS 2 27LP X05



EFF :

ALL  33-26-00

Page 502
Feb 01/07
 
IAC 
R **ON A/C ALL

4. Procedure
_________

Subtask 33-26-00-860-050

A. Preparation for the Test.

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

(2) Make sure that all lavatory doors are closed but not locked.

Subtask 33-26-00-710-050

B. Test of the FWD Lavatory Lighted Signs.

(1) Do the test of the lavatory lighted signs 3WJ and 6WJ.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. In the cockpit, on the INT LT


panel 25VU:
- set the ANN LT switch 33LP to
the BRT position.

2. At the lavatory A: In the cockpit, on the overhead panel


48VU:
- lift the sign LAVATORY and lock - the annunciator OCCPD 6WJ comes on.
the lavatory door.

In Zone 220:
- the green unoccupied pictorial symbol
3WJ goes off.
- the red occupied pictorial symbol 3WJ
comes on.

3. In the cockpit, on the INT LT In the cockpit, on the overhead panel


panel 25VU: 48VU:
- set the ANN LT switch 33LP to - the annunciator OCCPD 6WJ becomes
the DIM position. dim.

- set the ANN LT switch 33LP to - the annunciator OCCPD 6WJ becomes
the BRT position. bright.



EFF :

ALL  33-26-00

Page 503
May 01/06
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
4. At the lavatory A: In the cockpit, on the overhead panel
48VU:
- lift the sign LAVATORY and - the annunciator OCCPD 6WJ goes off.
unlock the lavatory door.

In Zone 220:
- the red occupied pictorial symbol 3WJ
goes off.
- the green unoccupied pictorial symbol
3WJ comes on.

R **ON A/C 001-012, 014-099,

Subtask 33-26-00-710-051

C. Test of the AFT Lavatory Lighted Signs.

(1) Do the test of the lavatory lighted signs 13WJ and 14WJ.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. At the lavatories D and E: In Zone 260:


- with the lavatory doors closed - the green unoccupied pictorial
but not locked. symbols 13WJ and 14WJ are on.

2. At lavatory D: In Zone 260:


- lift the sign LAVATORY and lock - the green unoccupied pictorial symbol
the lavatory door. 13WJ goes off.
- the red occupied pictorial symbol
13WJ comes on.

3. At lavatory E: In Zone 260:


- lift the sign LAVATORY and lock - the green unoccupied pictorial symbol
the lavatory door. 14WJ goes off.
- the red occupied pictorial symbol
14WJ comes on.

4. At lavatory D: In Zone 260:


- lift the sign LAVATORY and - the red occupied pictorial symbol
unlock the lavatory door. 13WJ goes off.



EFF :

ALL  33-26-00

Page 504
May 01/06
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- the green unoccupied pictorial symbol
13WJ comes on.

5. At lavatory E: In Zone 260:


- lift the sign LAVATORY and - the red occupied pictorial symbol
unlock the lavatory door. 14WJ goes off.
- the green unoccupied pictorial symbol
14WJ comes on.

R **ON A/C 101-199,

R Subtask 33-26-00-710-051-C

R C. Test of the AFT Lavatory Lighted Signs.

R (1) Do the test of the lavatory lighted signs 13WJ and 14WJ.

R -------------------------------------------------------------------------------
R ACTION RESULT
R -------------------------------------------------------------------------------

R 1. At the lavatory doors of the In Zone 260:


R lavatories D and L: - the green unoccupied pictorial symbol
R - lift the sign LAVATORY and lock 13WJ stays on.
R the door of the lavatory D.

R - lift the sign LAVATORY and lock - the green unoccupied pictorial symbol
R the door of the lavatory L. 13WJ goes off.
R - the red occupied pictorial symbol
R 13WJ comes on.

R - lift the sign LAVATORY and - the red occupied pictorial symbol
R unlock the door of the lavatory 13WJ goes off.
R D. - the green unoccupied pictorial symbol
R 13WJ comes on.

R - lift the sign LAVATORY and - the green unoccupied pictorial symbol
R unlock the door of the lavatory 13WJ stays on.
R L.

R 2. At the lavatory door of the In Zone 260:


R lavatory M: - the green unoccupied pictorial symbol
R - lift the sign LAVATORY and lock 14WJ goes off.



EFF :

001-012, 014-099, 101-199,  33-26-00

Page 505
May 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
the lavatory door. - the red occupied pictorial symbol
14WJ comes on.

- lift the sign LAVATORY and - the red occupied pictorial symbol
unlock the lavatory door. 14WJ goes off.
- the green unoccupied pictorial symbol
14WJ comes on.

R **ON A/C 901-999,

Subtask 33-26-00-710-051-B

C. Test of the AFT Lavatory Lighted Signs.

(1) Do the test of the lavatory lighted signs 13WJ and 14WJ.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. At the lavatories D and E: In Zone 260:


- with the lavatory doors closed - the green unoccupied pictorial
but not locked. symbols 13WJ and 14WJ are on.

2. At lavatory D: In Zone 260:


- lift the sign LAVATORY and lock - the green unoccupied pictorial symbol
the lavatory door. 13WJ goes off.
- the red occupied pictorial symbol
13WJ comes on.

3. At lavatory E: In Zone 260:


- lift the sign LAVATORY and lock - the green unoccupied pictorial symbol
the lavatory door. 14WJ goes off.
- the red occupied pictorial symbol
14WJ comes on.

4. At lavatory D: In Zone 260:


- lift the sign LAVATORY and - the red occupied pictorial symbol
unlock the lavatory door. 13WJ goes off.
- the green unoccupied pictorial symbol
13WJ comes on.

5. At lavatory E: In Zone 260:


R

EFF :

101-199, 901-999,  33-26-00

Page 506
Aug 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- lift the sign LAVATORY and - the red occupied pictorial symbol
unlock the lavatory door. 14WJ goes off.
- the green unoccupied pictorial symbol
14WJ comes on.

**ON A/C ALL

5. Close-up
________

Subtask 33-26-00-862-050

A. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-26-00

Page 507
Aug 01/07
 
IAC 
MICRO SWITCH - LAVATORY OCCUPIED - REMOVAL/INSTALLATION
_______________________________________________________

TASK 33-26-11-000-001

Removal of the Lavatory Door Microswitch (WJ)

NOTE : This procedure is the same for all lavatory door microswitches.
____

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-099,

33-26-11-991-001 Fig. 401

R **ON A/C 101-199, 901-999,

33-26-11-991-001-A Fig. 401A



EFF :

ALL  33-26-11

Page 401
Feb 01/07
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-26-11-991-001)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-26-11-991-001-A)

**ON A/C 001-012, 014-019,

Subtask 33-26-11-865-050-A

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAV LIGHT 1LQ C01
2000VU LAVATORY FORWARD - OCCUPIED 1WJ C06
2001VU LAVATORY AFT OCCUPIED 11WJ E07

R **ON A/C 020-099, 901-999,

Subtask 33-26-11-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAV LIGHT 1LQ C01
2000VU LAVATORY FWD & MID - OCCUPIED 1WJ C06
2001VU LAVATORY AFT OCCUPIED 11WJ E07



EFF :

ALL  33-26-11

Page 402
Feb 01/07
 
IAC 
Lavatory Door Microswitch
Figure 401/TASK 33-26-11-991-001


R

EFF :

001-012, 014-099,  33-26-11

Page 403
Aug 01/06
 
IAC 
Lavatory Door Microswitch
Figure 401A/TASK 33-26-11-991-001-A


R

EFF :

101-199, 901-999,  33-26-11

Page 404
Feb 01/07
 
IAC 
R **ON A/C 101-199,

R Subtask 33-26-11-865-050-B

R A. Open, safety and tag this(these) circuit breaker(s):

R -------------------------------------------------------------------------------
R PANEL SERVICE IDENT. LOCATION
R -------------------------------------------------------------------------------
R 2000VU LIGHT - LAV 1LQ J01
R 2000VU LAV FWD & MID - OCCUPIED 1WJ F01
R 2001VU LAVATORY AFT OCCUPIED 11WJ B04

**ON A/C ALL

Subtask 33-26-11-010-050

B. Open the lavatory door (1).

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-26-11-991-001)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-26-11-991-001-A)

**ON A/C 001-012, 014-099,

Subtask 33-26-11-020-050

A. Removal of the Lavatory Door Microswitch.

(1) Remove the recess-cover attachment screws (2) from the door frame
(9).

(2) Remove the recess-cover (3).

(3) Make a mark to show the position of the angle mount (4) in the door
frame (9).



EFF :

ALL  33-26-11

Page 405
Feb 01/07
 
IAC 
(4) Remove the microswitch (5) with angle mount (4) from the door frame
(9).

(5) Disconnect the electrical connection (10) from the microswitch (5).

(6) Put blanking caps on the electrical connectors.

(7) Remove the screws (8), lockwashers (7) and bushes (6),that attach the
microswitch (5) to the angle mount (4).

(8) Remove the microswitch (5) from the angle mount (4).

R **ON A/C 101-199, 901-999,

Subtask 33-26-11-020-050-A

A. Removal of the Lavatory Door Microswitch

(1) Remove the screws (7) from the door frame (2).

(2) Remove the angle support (6) with the microswitch (4) from the door
frame (2).

(3) Remove the screws (3) which attach the microswitch (4) to the angle
support (6).

(4) Disconnect the electrical connectors (5) from the microswitch (4).

(5) Put blanking caps on the electrical connectors.

(6) Remove the microswitch (4) from the angle support (6).


R

EFF :

ALL  33-26-11

Page 406
Feb 01/07
 
IAC 
R **ON A/C ALL

TASK 33-26-11-400-001

Installation of the Lavatory Door Microswitch (WJ)

NOTE : This procedure is the same for all lavatory door microswitches.
____

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

23-73-00-861-001 Energize the Cabin Intercommunication Data System


(CIDS)
23-73-00-862-001 De-energize the Cabin Intercommunication Data System
(CIDS)
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
33-26-11-000-001 Removal of the Lavatory Door Microswitch (WJ)
33-26-11-400-001 Installation of the Lavatory Door Microswitch (WJ)

R **ON A/C 001-012, 014-099,

33-26-11-991-001 Fig. 401



EFF :

ALL  33-26-11

Page 407
Aug 01/06
 
IAC 
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R **ON A/C 101-199, 901-999,

33-26-11-991-001-A Fig. 401A

**ON A/C 001-012, 014-099,

33-26-11-991-002 Fig. 402

**ON A/C ALL

3. __________
Job Set-up

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-26-11-991-001)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-26-11-991-001-A)

**ON A/C 001-012, 014-019,

Subtask 33-26-11-865-051-A

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAV LIGHT 1LQ C01
2000VU LAVATORY FORWARD - OCCUPIED 1WJ C06
2001VU LAVATORY AFT OCCUPIED 11WJ E07



EFF :

ALL  33-26-11

Page 408
Feb 01/07
 
IAC 
R **ON A/C 020-099, 901-999,

Subtask 33-26-11-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAV LIGHT 1LQ C01
2000VU LAVATORY FWD & MID - OCCUPIED 1WJ C06
2001VU LAVATORY AFT OCCUPIED 11WJ E07

R **ON A/C 101-199,

R Subtask 33-26-11-865-051-B

R A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
R tagged

R -------------------------------------------------------------------------------
R PANEL SERVICE IDENT. LOCATION
R -------------------------------------------------------------------------------
R 2000VU LIGHT - LAV 1LQ J01
R 2000VU LAV FWD & MID - OCCUPIED 1WJ F01
R 2001VU LAVATORY AFT OCCUPIED 11WJ B04

**ON A/C ALL

Subtask 33-26-11-410-050

B. Aircraft Maintenance Configuration

(1) Make sure that the lavatory door (1) is open.

(2) Clean the component interface and/or the adjacent area.

(3) Do an inspection of the component interface and/or the adjacent area.



EFF :

ALL  33-26-11

Page 409
Feb 01/07
 
IAC 
4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-26-11-991-001)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-26-11-991-001-A)

**ON A/C 001-012, 014-099,

Subtask 33-26-11-420-050

A. Installation of the Lavatory Door Microswitch.

(1) Install the microswitch (5) on the angle mount (4) with the screws
(8), lockwashers (7) and bushes (6).

(2) Remove the blanking caps and connect the electrical connectors (10)
to the microswitch (5).

(3) Install the microswitch (5) and angle mount (4) into the door frame
(9).

(4) Set the angle mount (4) to the position noted during removal.

(5) Put the recess-cover (3) in the correct position and install the
screws (2) and tighten the screws.

R **ON A/C 101-199, 901-999,

Subtask 33-26-11-420-050-A

A. Installation of the Lavatory Door Microswitch

(1) Install the microswitch (4) on the angle support (6) with the screws
(3).

(2) Remove the blanking caps and connect the electrical connectors (5) to
the microswitch (4).



EFF :

ALL  33-26-11

Page 410
Feb 01/07
 
IAC 
(3) Install the angle support (6) with the microswitch (4) into the door
frame (2).

(4) Install the screws (7) and tighten them.

**ON A/C ALL

Subtask 33-26-11-860-051

B. Preparation for Test.

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED
_______
BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

Subtask 33-26-11-865-052

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s): 1LQ, 1WJ, 11WJ.

Subtask 33-26-11-860-050

D. Energize the Cabin Intercommunication Data System (CIDS) (Ref. TASK 23-
73-00-861-001).



EFF :

ALL  33-26-11

Page 411
Feb 01/07
R  
IAC 
R **ON A/C 001-012, 014-099, 101-199,

Subtask 33-26-11-710-050

E. Test of the Lavatory Door Microswitch.

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the Forward Attendant Panel On the FAP 120RH:


(FAP) 120RH:

- Push the POWER LAV membrane - The green POWER LAV light in the
switch. membrane switch comes on.

In the lavatory:
- The lavatory lighting is dim.

2. In the lavatory:

- Close and lock the lavatory - The lavatory lighting becomes bright.
door.

- Unlock the lavatory door. - The lavatory lighting becomes dim.

3. On the FAP 120RH: On the FAP 120RH:

- Push the POWER LAV membrane - The green POWER LAV light in the
switch. membrane switch goes off.

In all lavatories:
- The lighting in all the lavatories
goes off.


R

EFF :

001-012, 014-099, 101-199,  33-26-11

Page 412
Feb 01/07
 
IAC 
R **ON A/C 901-999,

Subtask 33-26-11-710-050-A

E. Test of the Lavatory Door Microswitch.

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the Flight Attendant Panel On the FAP 120RH:


(FAP) 120RH:

- Push the LAV MAINT membrane - The LAV MAINT indication on the
switch. membrane switch comes on.

In the lavatory:
- The lavatory lighting is dim.

2. In the lavatory:

- Close and lock the lavatory - The lavatory lighting becomes bright.
door.

- Unlock the lavatory door. - The lavatory lighting becomes dim.

3. On the FAP 120RH: On the FAP 120RH:

- Push the LAV MAINT membrane - The LAV MAINT indication on the
switch. membrane switch goes off.

In all lavatories:
- The lighting goes off.


R

EFF :

901-999,  33-26-11

Page 413
Feb 01/07
 
IAC 
**ON A/C 001-012, 014-099,

Subtask 33-26-11-820-051

F. Adjustment of the Lavatory Door Microswitch.


(Ref. Fig. 402/TASK 33-26-11-991-002)

(1) If the lavatory light stays dim when the lavatory door is closed and
locked (door bolt is in position A):

- open the lavatory door.


- loosen the attachment screws and push the microswitch and angle
mount upwards.
- tighten the attachment screws.

(2) Repeat the test.

(3) If the range of adjustment is not sufficient, remove the microswitch


(Ref. TASK 33-26-11-000-001).

(4) Install the microswitch (Ref. TASK 33-26-11-400-001) and make sure
that the microswitch is moved in the direction of spring strip.

(5) Repeat the test.

**ON A/C ALL

5. Close-up
________

Subtask 33-26-11-860-052

A. Put the aircraft back to the serviceable condition.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) De-energize the CIDS system (Ref. TASK 23-73-00-862-001).

(3) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).


R

EFF :

ALL  33-26-11

Page 414
Feb 01/07
 
IAC 
Lavatory Door Bolt - Adjustment
Figure 402/TASK 33-26-11-991-002


R

EFF :

001-012, 014-099,  33-26-11

Page 415
Feb 01/07
 
IAC 
SIGN - LAVATORY OCCUPIED - REMOVAL/INSTALLATION
_______________________________________________

TASK 33-26-23-000-001

Removal of the Lavatory Occupied Signs (WJ)

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

NOTE : The procedure is the same for all lavatory occupied signs.
____

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific stepladder 1 m (3 ft. 3 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R **ON A/C 001-012, 014-099,

33-26-23-991-001 Fig. 401

**ON A/C 101-199,

33-26-23-991-001-B Fig. 401A

R **ON A/C 901-999,

33-26-23-991-001-A Fig. 401B



EFF :

ALL  33-26-23

Page 401
Aug 01/07
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

**ON A/C 001-012, 014-019,

Subtask 33-26-23-865-050-A

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAVATORY FORWARD - OCCUPIED 1WJ C06
2001VU LAVATORY AFT OCCUPIED 11WJ E07

R **ON A/C 020-099, 101-199, 901-999,

Subtask 33-26-23-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAVATORY FWD & MID - OCCUPIED 1WJ C06
2001VU LAVATORY AFT OCCUPIED 11WJ E07

**ON A/C ALL

Subtask 33-26-23-941-050

B. Get Access

(1) Find the related lavatory occupied sign.

(2) Put the stepladder in position below the lavatory occupied sign.



EFF :

ALL  33-26-23

Page 402
Feb 01/07
 
IAC 
4. Procedure
_________

R **ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-26-23-991-001)

**ON A/C 101-199,

(Ref. Fig. 401A/TASK 33-26-23-991-001-B)

R **ON A/C 901-999,

(Ref. Fig. 401B/TASK 33-26-23-991-001-A)

**ON A/C 001-012, 014-099,

Subtask 33-26-23-020-051

A. Removal of the Lavatory Occupied Sign and the Bulb(s)

(1) Removal of the Lavatory Occupied-Sign Assembly

(a) Lift and remove the lens (1).

(b) Remove the screws (2) and the washers (3).

(c) Pull the sign housing (5) sufficiently forward to get access to
the electrical connectors (4).

(d) Support the sign housing (5) and identify all the electrical
wires before you disconnect them.

(e) Disconnect the electrical connectors (4).

(f) Remove the sign housing (5).

(2) Removal of the Bulb(s) of the Lavatory Occupied Sign

NOTE : If you have the lavatory occupied signs with LEDs installed,
____
the subsequent procedure is not applicable, you must remove
the complete sign housing (5) with the LEDs (see above).

(a) Lift and remove the lens (1).



EFF :

ALL  33-26-23

Page 403
Aug 01/07
 
IAC 
Lavatory Occupied Sign
Figure 401/TASK 33-26-23-991-001


R

EFF :

001-012, 014-099,  33-26-23

Page 404
Aug 01/07
 
IAC 
R Lavatory Occupied Sign
Figure 401A/TASK 33-26-23-991-001-B



EFF :

101-199,  33-26-23

Page 405
Feb 01/08
 
IAC 
Lavatory Occupied Sign
Figure 401B/TASK 33-26-23-991-001-A


R

EFF :

901-999,  33-26-23

Page 406
Aug 01/07
 
IAC 
(b) Remove the bulb(s) (6).

NOTE : Obey the color of the bulb(s).


____

**ON A/C 101-199, 901-999,

Subtask 33-26-23-020-051-A

A. Removal of the Lavatory Occupied Sign

(1) Lift and remove the lens (1).

(2) Remove the screws (2) and the washers (3).

(3) Pull the sign housing (5) sufficiently forward to get access to the
electrical connectors (4).

(4) Support the sign housing (5) and identify all the electrical wires
before you disconnect them.

(5) Disconnect the electrical connectors (4).

(6) Remove the sign housing (5).



EFF :

ALL  33-26-23

Page 407
May 01/07
R  
IAC 
**ON A/C ALL

TASK 33-26-23-400-001

Installation of the Lavatory Occupied Signs (WJ)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific stepladder 1 m (3 ft. 3 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-26-00-710-001 Operational Test of the Lavatory Lighted Signs WJ

R **ON A/C 001-012, 014-099,

33-26-23-991-001 Fig. 401

**ON A/C 101-199,

33-26-23-991-001-B Fig. 401A

R **ON A/C 901-999,

33-26-23-991-001-A Fig. 401B



EFF :

ALL  33-26-23

Page 408
Aug 01/07
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

**ON A/C 001-012, 014-019,

Subtask 33-26-23-865-051-A

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAVATORY FORWARD - OCCUPIED 1WJ C06
2001VU LAVATORY AFT OCCUPIED 11WJ E07

**ON A/C 020-099, 101-199, 901-999,

Subtask 33-26-23-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LAVATORY FWD & MID - OCCUPIED 1WJ C06
2001VU LAVATORY AFT OCCUPIED 11WJ E07

**ON A/C ALL

Subtask 33-26-23-941-052

B. Make sure that the stepladder is in position below the lavatory occupied
sign.

4. Procedure
_________

R **ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-26-23-991-001)



EFF :

ALL  33-26-23

Page 409
Aug 01/07
 
IAC 
**ON A/C 101-199,

(Ref. Fig. 401A/TASK 33-26-23-991-001-B)

R **ON A/C 901-999,

(Ref. Fig. 401B/TASK 33-26-23-991-001-A)

**ON A/C 001-012, 014-099,

Subtask 33-26-23-420-050

A. Installation of the Lavatory Occupied Sign and the Bulb(s)

(1) Installation of the Lavatory Occupied-Sign Assembly

(a) Clean the component interface and/or the adjacent area.

(b) Do an inspection of the component interface and/or the adjacent


area.

(c) Make sure that the electrical connectors are clean and in the
correct condition.

(d) Connect the electrical connectors (4) as identified during the


removal procedure to the sign housing (5).

(e) Install the sign housing (5) with the washers (3) and the screws
(2).

(f) Install the lens (1) to the sign housing (5).


Make sure that you hear a click when the lens (1) locks in
position .

(2) Installation of the Bulb(s) of the Lavatory Occupied Sign

NOTE : If you have the lavatory occupied signs with LEDs installed,
____
the subsequent procedure is not applicable, you must install
the complete sign housing (5) with the LEDs (see above).

(a) Clean the component interface and/or the adjacent area.

(b) Do an inspection of the component interface and/or the adjacent


area.


R

EFF :

ALL  33-26-23

Page 410
Aug 01/07
 
IAC 
(c) Install the bulb(s) (6) to the sign housing (5).

NOTE : Obey the color of the bulb(s).


____

(d) Install the lens (1) to the sign housing (5).


Make sure that you hear a click when the lens (1) locks in
position .

**ON A/C 101-199, 901-999,

Subtask 33-26-23-420-050-A

A. Installation of the Lavatory Occupied Sign

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Make sure that the electrical connectors are clean and in the correct
condition.

(4) Connect the electrical connectors (4) as identified during the


removal procedure to the sign housing (5).

(5) Install the sign housing (5) with the washers (3) and the screws (2).

(6) Install the lens (1) on the sign housing (5).


Make sure that you hear a click when the lens (1) locks in position.

**ON A/C ALL

Subtask 33-26-23-865-052

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1WJ, 11WJ.

Subtask 33-26-23-710-050

C. Test of the Lavatory Lighted Signs WJ

(1) Do the operational test of the lavatory lighted signs (Ref. TASK 33-
26-00-710-001).



EFF :

ALL  33-26-23

Page 411
May 01/07
R  
IAC 
5. Close-up
________

Subtask 33-26-23-942-051

A. Put the aircraft back to the serviceable condition.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the stepladder.



EFF :

ALL  33-26-23

Page 412
May 01/07
 
IAC 
LIGHT - WORK, CABIN ATTENDANT - DESCRIPTION AND OPERATION
_________________________________________________________

1. _______
General
The cabin attendant work-lights (referred to as the work lights) are high
intensity work-lights which are installed at the attendant stations.

2. __________________
Component Location

**ON A/C 001-012, 014-099,

(Ref. Fig. 001)

-------------------------------------------------------------------------------
FIN FUNCTIONAL DESIGNATION PANEL ZONE ACCESS
DOOR
-------------------------------------------------------------------------------
2LZ RELAY - POWER CONTROL 2000VU 221
3LZ POWER UNIT 2000VU 221
4LZ ATTENDANT WORK LIGHT 2000VU 221
5LZ ATTENDANT WORK LIGHT 2000VU 221
10LZ ATTENDANT WORK LIGHT 2001VU 264
12LZ POWER UNIT 2001VU 264
13LZ POWER UNIT 2042VU 263
14LZ ATTENDANT WORK LIGHT 2042VU 263
15LZ ATTENDANT WORK LIGHT 2001VU 264

R **ON A/C 101-199,

R (Ref. Fig. 001A)

R -------------------------------------------------------------------------------
R FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
R | | | | DOOR | REF.
R -------------------------------------------------------------------------------
R 6LZ PUSHBUTTON SWITCH 2063VU 220 33-27-00
R 7LZ PUSHBUTTON SWITCH 2063VU 220 33-27-00
R 203LZ StA-PISA 2000VU 220 33-27-41
R 204LZ ATTENDANT WORK LIGHT 2000VU 220 33-27-12
R 205LZ ATTENDANT WORK LIGHT 2000VU 220 33-27-12
R 16LZ PUSHBUTTON SWITCH 2062VU 260 33-27-00
R 212LZ StA-PISA 2001VU 260 33-27-41
R 210LZ ATTENDANT WORK LIGHT 2001VU 260 33-27-12
R 214LZ ATTENDANT WORK LIGHT 612RH 260 33-27-12



EFF :

ALL  33-27-00

Page 1
May 01/07
 
IAC 
Cabin Attendant Work-Light - Component Location
Figure 001


R

EFF :

001-012, 014-099,  33-27-00

Page 2
May 01/06
 
IAC 
R Cabin Attendant Work-Light - Component Location
R Figure 001A



EFF :

101-199,  33-27-00

Page 3
May 01/07
 
IAC 
R **ON A/C 901-999,

(Ref. Fig. 001B)

-------------------------------------------------------------------------------
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
6LZ PUSHBUTTON SWITCH 2063VU 220 33-27-00
7LZ PUSHBUTTON SWITCH 2063VU 220 33-27-00
203LZ StA-PISA 2000VU 220 33-27-41
204LZ ATTENDANT WORK LIGHT 2000VU 220 33-27-12
205LZ ATTENDANT WORK LIGHT 2000VU 220 33-27-12
6LZ PUSHBUTTON SWITCH 2063VU 260 33-27-00
7LZ PUSHBUTTON SWITCH 2063VU 260 33-27-00
16LZ PUSHBUTTON SWITCH 2062VU 260 33-27-00
212LZ StA-PISA 2001VU 260 33-27-41
211LZ ATTENDANT WORK LIGHT 2001VU 260 33-27-12
215LZ ATTENDANT WORK LIGHT 2001VU 260 33-27-12
214LZ ATTENDANT WORK LIGHT 612RH 260 33-27-12

**ON A/C ALL

3. __________________
System Description

R **ON A/C 001-012, 014-099,

A. Cabin Attendant Work-Light


The 115VAC from the busbar 210XP supplies the work lights through the
circuit breaker 1LZ ATTN WORK LIGHT and the power control relay 2LZ. The
work lights and the power units are installed in the overhead panels
above the cabin attendant seats. The power units change 115VAC to 6VAC
for the light operation. The membrane switch POWER ATTN on the forward
attendant panel 120RH controls the power supply for the work lights.

Push the MAIN OFF membrane switch on the forward attendant panel 120RH to
turn off the work lights together with all lights in other cabin systems.

The power unit is connected to a Decoder/Encoder Unit (DEU) of the Cabin


Intercommunication Data System (CIDS). A test of the work lights is made
from the CIDS system.



EFF :

ALL  33-27-00

Page 4
Aug 01/07
 
IAC 
Cabin Attendant Work-Light - Component Location
Figure 001B


R

EFF :

901-999,  33-27-00

Page 5
Aug 01/07
 
IAC 
R **ON A/C 101-199, 901-999,

A. Cabin Attendant Work-Light


The 115VAC from the busbar 210XP supplies the work lights through the
circuit breaker 1LZ ATTN WORK LIGHT and the Stand Alone - Passenger
Interface and Supply Adapters (StA-PISAs) 203LZ and 212LZ. The work
lights and the StA-PISAs are installed in the overhead panels above the
cabin attendant seats. The StA-PISAs change 115VAC to 28VDC for the
R operation of the light. The attendant work lights are controlled by
R buttons in the attendant area.

R Push the LIGHTS MAIN ON/OFF button at the Flight Attendant Panel (FAP)
R 120RH to turn on/off the work lights at the same time with all the lights
in the other cabin systems.

The StA-PISAs are connected to a Decoder/Encoder Unit (DEU) of the Cabin


Intercommunication Data-System (CIDS). A test of the work lights is made
from the CIDS.

**ON A/C ALL

4. _____________________
Component Description

R **ON A/C 001-012, 014-099,

R
(Ref. Fig. 002)
R

A. Cabin Attendant Work-Light


Push the membrane switch POWER ATTN on the forward attendant panel 120RH
to supply 28VDC to the relay 2LZ. The relay 2LZ energizes and completes
the 115VAC supply to all the power units.

Push the work light membrane-switch to complete the 6VAC circuit for the
work light. The related work light comes on. The integral light in the
membrane switch comes on when the work light operates.

Push the work light membrane-switch again to turn off the related work
light.
Push the POWER ATTN membrane switch on the forward attendant panel 120RH
again to turn off all the work lights.


R

EFF :

ALL  33-27-00

Page 6
Aug 01/07
 
IAC 
Cabin Attendant Work-Light - Schematic
Figure 002


R

EFF :

001-012, 014-099,  33-27-00

Page 7
May 01/07
 
IAC 
Push the MAIN OFF membrane switch on the forward attendant panel 120RH to
turn off all the work lights together with the lights in other cabin
systems.

R **ON A/C 101-199, 901-999,

**ON A/C 101-199,

(Ref. Fig. 002A)

R **ON A/C 901-999,

(Ref. Fig. 002B)

R **ON A/C 101-199, 901-999,

A. The system of the cabin attendant work-lights give lighting to each


attendant seat independently. The Passenger Interface and Supply Adapters
(PISA) supply the cabin attendant work-lights. These units change the
voltage from 115VAC to 28VDC.
For the operation touch the Main ON/OFF button on the LIGHT page of
the FAP 120RH to ON.
An interface to the CIDS is included for the test function (Ref.
23-73-00).


R

EFF :

ALL  33-27-00

Page 8
Aug 01/07
 
IAC 
INTENTIONALLY BLANK


R



 33-27-00

Page 9
Aug 01/07
 
IAC 
Cabin Attendant Work-Light - Schematic
Figure 002A (SHEET 1)


R

EFF :

101-199,  33-27-00

Page 10
Aug 01/07
 
IAC 
Cabin Attendant Work-Light - Schematic
Figure 002A (SHEET 2)


R

EFF :

101-199,  33-27-00

Page 11
Aug 01/07
 
IAC 
Cabin Attendant Work-Light - Schematic
Figure 002B (SHEET 1)


R

EFF :

901-999,  33-27-00

Page 12
Aug 01/07
 
IAC 
Cabin Attendant Work-Light - Schematic
Figure 002B (SHEET 2)


R

EFF :

901-999,  33-27-00

Page 13
Aug 01/07
 
IAC 
LIGHT - WORK, CABIN ATTENDANT - ADJUSTMENT/TEST
_______________________________________________

TASK 33-27-00-710-001

Operational Test of the Cabin Attendant Work-Light

1. __________________
Reason for the Job

To make sure that the cabin attendant work-lights operate correctly.

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

23-73-00-861-001 Energize the Cabin Intercommunication Data System


(CIDS)
23-73-00-862-001 De-energize the Cabin Intercommunication Data System
(CIDS)
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-27-00-860-050

A. Aircraft Maintenance Configuration

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

(2) Energize the Cabin Intercommunication Data System (CIDS) (Ref. TASK
23-73-00-861-001).



EFF :

ALL  33-27-00

Page 501
May 01/06
R  
IAC 
**ON A/C 001-012, 014-099,

Subtask 33-27-00-865-050

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LIGHT - ATTND WORK 1LZ J05

R **ON A/C 101-199, 901-999,

Subtask 33-27-00-865-050-A

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LIGHT - ATTND WORK 1LZ J03



EFF :

ALL  33-27-00

Page 502
Feb 01/07
 
IAC 
**ON A/C ALL

4. Procedure
_________

R **ON A/C 001-012, 014-099,

Subtask 33-27-00-710-050

A. Do this test of the cabin attendant work-lights.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the Forward Attendant Panel On the FAP 120RH:


(FAP) 120RH:

- push the POWER ATTN membrane - the POWER ATTN integral light of the
switch. membrane switch comes on.

2. On the switch panels 2062VU and On the circuit breaker panels 2000VU,
2063VU: 2001VU and the Passenger Service /
Information Unit (PS/IU) 2042VU:

- push the cabin-attendant - the cabin attendant work-lights come


work-light pushbutton-switches. on.

3. On the FAP 120RH: On the FAP 120RH:

- push the POWER ATTN membrane - the POWER ATTN integral light of the
switch. membrane switch goes off.

On the circuit breaker panels 2000VU,


2001VU and the PS/IU 2042VU:

- all the cabin attendant work-lights


go off.

On the FAP 120RH: On the FAP 120RH:

- in less then 10 s push the - the POWER ATTN integral light of the
POWER ATTN membrane switch membrane switch comes on.
again.



EFF :

ALL  33-27-00

Page 503
Aug 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
On the circuit breaker panels 2000VU,
2001VU and the PS/IU 2042VU.

- all the cabin attendant work-lights


come on.

4. On the switch panels 2062VU and On the circuit breaker panels 2000VU,
2063VU: 2001VU and the PS/IU 2042VU:

- push the cabin-attendant - the cabin attendant work-lights go


work-light pushbutton-switches. off.

5. On the FAP 120RH: On the FAP 120RH:

- push the POWER ATTN membrane - the POWER ATTN integral light of the
switch. membrane switch goes off.

**ON A/C 101-199,

Subtask 33-27-00-710-050-B

A. Test of the Cabin Attendant Work-lights

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the Flight Attendant Panel On the FAP 120RH:


(FAP) 120RH:

- Push the LIGHT MAIN ON/OFF - The LIGHT MAIN ON/OFF indication on
membrane switch. the membrane switch comes on.

- Set the LIGHT page. - All possible cabin lighting zones are
shown.

2. Forward attendant work-lights:

On the panel 2063VU1 at the head On the panel 2000VU:


cushion of the attendant seats at
the door 1 LH:


R

EFF :

001-012, 014-099, 101-199,  33-27-00

Page 504
Aug 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
R - Push the pushbutton 6LZ. - The cabin attendant work-light 205LZ
R comes on.

R - Push the pushbutton 6LZ again. - The cabin attendant work-light 205LZ
R goes off.

R - Push the pushbutton 7LZ. - The cabin attendant work-light 204LZ


R comes on.

R - Push the pushbutton 7LZ again. - The cabin attendant work-light 204LZ
R goes off.

R 3. Aft attendant work-lights:

R On the panel 2062VU2: On the panel 612RH:

R - Push the pushbutton 16LZ. - The cabin attendant work-light 214LZ


R comes on.

R - Push the pushbutton 16LZ again. - The cabin attendant work-light 214LZ
R goes off.

R On the panel 2062VU1: On the panel 2001VU:

R - Push the pushbutton 16LZ. - The cabin attendant work-light 210LZ


R comes on.

R - Push the pushbutton 16LZ again. - The cabin attendant work-light 210LZ
R goes off.


R

EFF :

101-199,  33-27-00

Page 505
May 01/07
 
IAC 
**ON A/C 901-999,

Subtask 33-27-00-710-050-A

A. Test of the Cabin Attendant Work-lights

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the Flight Attendant Panel On the FAP 120RH:


(FAP) 120RH:

- Push the LIGHT MAIN ON/OFF - The LIGHT MAIN ON/OFF indication on
membrane switch. the membrane switch comes on.

- Set the LIGHT page. - All possible cabin lighting zones are
shown.

2. Forward attendant work-lights:

On the panel 2063VU1 at the head On the panel 2000VU:


cushion of the attendant seats at
the door 1 LH:

R - Push the button 6LZ. - The cabin attendant work-light 205LZ


comes on.

R - Push the button 6LZ again. - The cabin attendant work-light 205LZ
goes off.

R - Push the button 7LZ. - The cabin attendant work-light 204LZ


comes on.

R - Push the button 7LZ again. - The cabin attendant work-light 204LZ
goes off.

3. Aft attendant work-lights:

On the panel 2062VU2: On the panel 612RH:

R - Push the button 16LZ. - The cabin attendant work-light 214LZ


comes on.



EFF :

901-999,  33-27-00

Page 506
May 01/08
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
R - Push the button 16LZ again. - The cabin attendant work-light 214LZ
goes off.

R On the panel 2063VU2: On the panel 2001VU:

R - Push the button 6LZ. - The cabin attendant work-light 211LZ


comes on.

R - Push the button 6LZ again. - The cabin attendant work-light 211LZ
goes off.

R - Push the button 7LZ. - The cabin attendant work-light 215LZ


comes on.

R - Push the button 7LZ again. - The cabin attendant work-light 215LZ
goes off.

**ON A/C 001-012, 014-099,

Subtask 33-27-00-740-050

B. Do this BITE test of the cabin attendant work-lights and passenger


reading lights on the Programming and Test Panel (PTP) 110RH.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the FAP 120RH: On the FAP 120RH:

- push the POWER READ and POWER - the POWER READ and POWER ATTN
ATTN membrane switches. integral lights of the membrane
switches come on.

2. On the PTP 110RH: On the PTP 110RH:

- push the DSPL ON membrane - the CIDS menu comes on.


switch.

- push the SYSTEM TEST line - the SYSTEM TEST menu comes on.
select key.



EFF :

001-012, 014-099, 901-999,  33-27-00

Page 507
May 01/08
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- push CONT until the
READING/WORK LIGHTS display
comes on.

- push the READING/WORK LIGHTS - the page RDG/WORK LIGHTS TEST comes
line select key. on.

- the WAIT FOR RESPONSE display comes


on and flashes.

In the cabin:

- all the cabin attendant work-lights


and passenger reading lights come on
for approx. 3 s then go off.

On the PTP 110RH:

- the display RDG/WORK LIGHTS ATA


23-73-00 TEST OK comes on.

3. On the PTP 110RH: On the PTP 110RH:

- push the DSPL ON membrane - the CIDS menu comes on.


switch.

4. On the FAP 120RH: On the FAP 120RH:

- push the POWER READ and POWER - the POWER READ and POWER ATTN
ATTN membrane switches. integral lights of the membrane
switches go off.


R

EFF :

001-012, 014-099,  33-27-00

Page 508
May 01/07
 
IAC 
**ON A/C ALL

5. Close-up
________

Subtask 33-27-00-862-050

A. Put the aircraft back to the serviceable condition.

(1) De-energize the CIDS (Ref. TASK 23-73-00-862-001).

(2) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-27-00

Page 509
May 01/07
R  
IAC 
TASK 33-27-00-740-001

Bite Test of the Cabin Attendant Work-Light through MCDU

1. __________________
Reason for the Job

To make sure that the cabin attendant work-lights operate correctly.

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

23-73-00-861-001 Energize the Cabin Intercommunication Data System


(CIDS)
23-73-00-862-001 De-energize the Cabin Intercommunication Data System
(CIDS)
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
31-32-00-860-003 Procedure to Get Access to the SYSTEM REPORT/TEST/COM
Page

3. __________
Job Set-up

Subtask 33-27-00-860-051

A. Aircraft Maintenance Configuration

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

(2) Energize the Cabin Intercommunication Data System (CIDS) (Ref. TASK
23-73-00-861-001).

(3) Procedure to Get Access to the SYSTEM REPORT/TEST/COM Page (Ref. TASK
31-32-00-860-003).



EFF :

ALL  33-27-00

Page 510
May 01/07
R  
IAC 
R **ON A/C 001-012, 014-099,

Subtask 33-27-00-865-052

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LIGHT - ATTND WORK 1LZ J05

R **ON A/C 101-199, 901-999,

R Subtask 33-27-00-865-052-A

R B. Make sure that this(these) circuit breaker(s) is(are) closed:

R -------------------------------------------------------------------------------
R PANEL SERVICE IDENT. LOCATION
R -------------------------------------------------------------------------------
R 2000VU LIGHT - ATTND WORK 1LZ J03



EFF :

ALL  33-27-00

Page 511
May 01/08
 
IAC 
R **ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

Subtask 33-27-00-740-051

A. BITE Test of the Cabin Attendant Work-lights and Passenger Reading Lights
on the Multipurpose Control and Display Unit (MCDU) 3CA

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the FAP 120RH: On the FAP 120RH:

- Push the POWER READ and POWER - the POWER READ and POWER ATTN
ATTN membrane switches. indication lights of the membrane
switches come on.

2. On the MCDU: On the MCDU screen:

- Push the line key adjacent to - The CIDS 1 main menu page comes on.
the CIDS 1 indication.

- Push the TEST line select key. - The CIDS 1 TEST menu comes on.

- Push the NEXT PAGE key until


the READING/WORK LIGHTS display
comes on.

- Push the READING/WORK LIGHTS - The page RDG/WORK LIGHTS TEST comes
line select key. on.

- The WAIT FOR RESPONSE display comes


on and flashes.

In the cabin:

- All the cabin attendant work-lights


and passenger reading lights come on
for approx. 3 s then go off.



EFF :

ALL  33-27-00

Page 512
May 01/08
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
On the MCDU screen:

- The display RDG/WORK LIGHTS ATA


23-73-64 TEST OK comes on.

3. On the MCDU: On the MCDU screen:

- Push the MCDU MENU key. - The MCDU menu comes on.

4. On the FAP 120RH: On the FAP 120RH:

- Push the POWER READ and POWER - The POWER READ and POWER ATTN
ATTN membrane switches. indication lights of the membrane
switches go off.

**ON A/C 101-199, 901-999,

Subtask 33-27-00-740-051-A

A. BITE-test of the Cabin Attendant Work-lights and Passenger Reading Lights


on the Multipurpose Control and Display Unit (MCDU) 3CA

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the MCDU: On the MCDU screen:

- Push the line select key - The CIDS main menu page comes on.
adjacent to the CIDS 1
indication.

- Push the line select key - The SYSTEM/TESTS menu page comes on.
adjacent to the SYSTEM TESTS >
indication.

- Push the line select key - The ILLUMINATION TEST menu page comes
adjacent to the < ILLUMINATION on.
TEST indication.



EFF :

ALL  33-27-00

Page 513
May 01/08
R  
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- Push the line select key - The display TEST IN PROGRESS 5s comes
adjacent to the < START TEST on.
indication.

In the cabin:
- All the passenger reading lights come
on for approx. 5s.

On the MCDU screen:


- The display TEST OK comes on.

- Push the line select key - The CIDS main menu page comes on.
adjacent to the RETURN
indication.

**ON A/C ALL

5. Close-up
________

Subtask 33-27-00-862-051

A. Put the aircraft back to the serviceable condition.

(1) On the MCDU, set the BRT knob to the OFF position.

(2) De-energize the CIDS (Ref. TASK 23-73-00-862-001).

(3) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-27-00

Page 514
May 01/08
 
IAC 
LIGHT - WORK, CABIN ATTENDANT (4LZ,5LZ,10LZ,14LZ) - REMOVAL/INSTALLATION
________________________________________________________________________

TASK 33-27-12-000-001

Removal of the Cabin Attendant Work-Lights

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

WARNING : YOU MUST BE CAREFUL WHEN YOU OPEN THE PANELS 2000VU OR 2001VU AS
_______
THESE ARE IN A HIGH VOLTAGE AREA.

NOTE : The removal procedure is the same for all cabin attendant work-lights.
____

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
FOR FIN 4LZ, 5LZ
No specific stepladder 1 m (3 ft. 3 in.)
FOR FIN 10LZ, 15LZ
No specific stepladder 1 m (3 ft. 3 in.)
FOR FIN 14LZ
No specific stepladder 1 m (3 ft. 3 in.)
FOR FIN 204LZ, 205LZ
No specific stepladder 1 m (3 ft. 3 in.)
FOR FIN 210LZ
No specific stepladder 1 m (3 ft. 3 in.)
FOR FIN 214LZ
No specific stepladder 1 m (3 ft. 3 in.)
FOR FIN 211LZ, 215LZ
No specific stepladder 1 m (3 ft. 3 in.)
R



EFF :

ALL  33-27-12

Page 401
Aug 01/07
 
IAC 
B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R **ON A/C 001-012, 014-099,

33-27-12-991-001 Fig. 401

R **ON A/C 101-199, 901-999,

33-27-12-991-001-A Fig. 401A

**ON A/C ALL

3. __________
Job Set-up

**ON A/C 001-012, 014-099,

Subtask 33-27-12-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LIGHT - ATTND WORK 1LZ J05

**ON A/C 101-199, 901-999,

Subtask 33-27-12-865-050-A

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LIGHT - ATTND WORK 1LZ J03



EFF :

ALL  33-27-12

Page 402
Aug 01/07
 
IAC 
**ON A/C 001-012, 014-099,

Subtask 33-27-12-010-050

B. Get Access

(1) FOR 4LZ, 5LZ

(a) Put the stepladder in position below the related panel.

(b) Lower the circuit breaker panel 2000VU.

(2) FOR 10LZ, 15LZ

(a) Put the stepladder in position below the related panel.

(b) Lower the circuit breaker panel 2001VU.

(3) FOR 14LZ

(a) Put the stepladder in position below the related panel.

(b) Disengage and lower one side of the combi panel 2042VU.

R **ON A/C 101-199,

R Subtask 33-27-12-010-050-C

R B. Get Access

R (1) FOR 204LZ, 205LZ

R (a) Put the stepladder in position below the related panel.

R (b) Lower the circuit breaker panel 2000VU.

R (2) FOR 210LZ

R (a) Put the stepladder in position below the related panel.

R (b) Lower the circuit breaker panel 2001VU.



EFF :

001-012, 014-099, 101-199,  33-27-12

Page 403
May 01/07
 
IAC 
(3) FOR 214LZ

(a) Put the stepladder in position below the related panel.

(b) Disengage and lower one side of the Passenger Service Unit (PSU)
612RH.

R **ON A/C 901-999,

Subtask 33-27-12-010-050-B

B. Get Access

(1) FOR 204LZ, 205LZ

(a) Put the stepladder in position below the related panel.

(b) Lower the circuit breaker panel 2000VU.

(2) FOR 211LZ, 215LZ

(a) Put the stepladder in position below the related panel.

(b) Lower the circuit breaker panel 2001VU.

(3) FOR 214LZ

(a) Put the stepladder in position below the related panel.

(b) Disengage and lower one side of the PSU 612RH.


R

**ON A/C ALL

4. Procedure
_________

R **ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-27-12-991-001)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-27-12-991-001-A)


R

EFF :

ALL  33-27-12

Page 404
Aug 01/07
 
IAC 
Cabin Attendant Work-Light.
Figure 401/TASK 33-27-12-991-001


R

EFF :

001-012, 014-099,  33-27-12

Page 405
Aug 01/07
 
IAC 
Cabin Attendant Work-Light.
Figure 401A/TASK 33-27-12-991-001-A


R

EFF :

101-199, 901-999,  33-27-12

Page 406
Aug 01/07
 
IAC 
**ON A/C ALL

Subtask 33-27-12-020-051

A. Removal of the Cabin Attendant Work-Lights

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.

(1) Disconnect the electrical connectors (2) from the cabin attendant
R work-lights (3).

(2) Put blanking caps on the disconnected electrical connectors.

(3) Remove the circlip (1) and the cabin attendant work-lights (3).


R

EFF :

ALL  33-27-12

Page 407
Aug 01/07
 
IAC 
TASK 33-27-12-400-001

Installation of the Cabin Attendant Work-Lights

NOTE : The installation procedure is the same for all cabin attendant
____
work-lights.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific 1 STEPLADDER 1.0 M (3.3 FT)


8PE004363-10 1 ADJUSTING DEVICE
8PE455160-20 1 TOOL-ADJUSTMENT, READING LIGHT
R 8PE455838-00 1 TOOL - ADJUSTMENT, READING LIGHT

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

**ON A/C 001-012, 014-099,

33-27-12-991-001 Fig. 401

**ON A/C 101-199, 901-999,

33-27-12-991-001-A Fig. 401A



EFF :

ALL  33-27-12

Page 408
Feb 01/08
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

**ON A/C 001-012, 014-099,

Subtask 33-27-12-865-051

A. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LIGHT - ATTND WORK 1LZ J05

**ON A/C 101-199, 901-999,

Subtask 33-27-12-865-051-A

A. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LIGHT - ATTND WORK 1LZ J03

**ON A/C ALL

4. Procedure
_________

R **ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-27-12-991-001)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-27-12-991-001-A)



EFF :

ALL  33-27-12

Page 409
Aug 01/07
 
IAC 
**ON A/C ALL

Subtask 33-27-12-860-050

A. Preparation for Installation

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Make sure that the STEPLADDER 1.0 M (3.3 FT) is in position below the
related panel.

(4) Make sure that the related circuit breaker panel is lowered.

Subtask 33-27-12-420-050

B. Installation of the Cabin Attendant Work-Lights

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.

(1) Install the cabin attendant work-lights (3) with the circlip (1).

R (2) Remove the blanking caps from the electrical connectors.

R (3) Make sure that the electrical connectors are clean and in the correct
condition.

R (4) Connect the electrical connectors (2) to the cabin attendant


work-lights (3).

**ON A/C 001-012, 014-099,

Subtask 33-27-12-410-052

C. Close Access

(1) FOR 4LZ, 5LZ

(a) Close the circuit breaker panel 2000VU.



EFF :

ALL  33-27-12

Page 410
Aug 01/07
 
IAC 
(2) FOR 10LZ, 15LZ

(a) Close the circuit breaker panel 2001VU.

(3) FOR 14LZ

(a) Close and engage the combi panel 2042VU.

**ON A/C 101-199,

Subtask 33-27-12-410-052-C

C. Close Access

(1) FOR 204LZ, 205LZ

(a) Close the circuit breaker panel 2000VU.

(2) FOR 210LZ

(a) Close the circuit breaker panel 2001VU.

(3) FOR 214LZ

(a) Close and engage the PSU 612RH.

R **ON A/C 901-999,

Subtask 33-27-12-410-052-B

C. Close Access

(1) FOR 204LZ, 205LZ

(a) Close the circuit breaker panel 2000VU.

(2) FOR 211LZ, 215LZ

(a) Close the circuit breaker panel 2001VU.

(3) FOR 214LZ

(a) Close and engage the PSU 612RH.


R


R

EFF :

ALL  33-27-12

Page 411
Aug 01/07
 
IAC 
**ON A/C ALL

Subtask 33-27-12-865-052

D. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LZ.

**ON A/C 001-012, 014-099,

Subtask 33-27-12-860-051

E. Preparation for the Test

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

(2) Remove the lens (4) from the related cabin attendant work-light.

(3) Install the ADJUSTING DEVICE to the work-light housing-rim and turn
clockwise to lock.

(4) On the forward attendant panel 120RH push the MAIN ON and POWER ATTN
pushbutton switches.

R **ON A/C 101-199, 902-999,

R Subtask 33-27-12-860-051-B

R E. Preparation for the Test

R NOTE : The lens (4) stays on the TOOL - ADJUSTMENT, READING LIGHT during
____
R the adjustment procedure.

R (1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


R 002).

R (2) Install the TOOL - ADJUSTMENT, READING LIGHT to remove the lens (4)
R from the related cabin attendant work-light (3).

R (3) Turn the small end of the TOOL - ADJUSTMENT, READING LIGHT in the
R direction of the cabin attendant work-light (3).



EFF :

ALL  33-27-12

Page 412
Feb 01/08
 
IAC 
R (4) Install the TOOL - ADJUSTMENT, READING LIGHT to the cabin attendant
R work-light (3) and lock it.

R (5) On the Flight Attendant Panel (FAP) 120RH push the LIGHT MAIN
R ON/OFF button.

R **ON A/C 901-901,

Subtask 33-27-12-860-051-A

E. Preparation for the Test

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

(2) Remove the lens (4) from the related cabin attendant work-light (3).

(3) Install the TOOL-ADJUSTMENT, READING LIGHT to the work-light


housing-rim and turn clockwise to lock.

(4) On the Flight Attendant Panel (FAP) 120RH push the LIGHT MAIN ON/OFF
button.

**ON A/C ALL

Subtask 33-27-12-710-051

F. Test of the Cabin Attendant Work-Lights

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the panels 2062VU or 2063VU: On the related work light:

- Push the related button to on. - The work light beam will fall onto
the related cabin attendant seat.

On the related work light:



EFF :

ALL  33-27-12

Page 413
Feb 01/08
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- Adjust the beam with the - The work light beam will fall onto
optical adjusting tool to the the middle edge of the cabin
middle edge of the related attendant seat.
cabin attendant seat.

On the panels 2062VU or 2063VU:

- Push the related button to off. - The work light goes off.

5. Close-up
________

**ON A/C 001-012, 014-099,

Subtask 33-27-12-860-052

A. Put the aircraft back to the serviceable condition.

(1) On the forward attendant panel 120RH push the POWER ATTN pushbutton
switch to off.

(2) Turn the optical adjusting tool counterclockwise to unlock and


remove.

(3) Install the lens (4) into the work light housing.

(4) Make sure that the work area is clean and clear of tool(s) and other
items.

R **ON A/C 101-199, 902-999,

R Subtask 33-27-12-860-052-B

R A. Put the aircraft back to the serviceable condition.

R (1) On the FAP 120RH push the LIGHT MAIN ON/OFF button.

R (2) Unlock the TOOL - ADJUSTMENT, READING LIGHT and remove it from the
R cabin attendant work-light (3).

R (3) Turn the end of the TOOL - ADJUSTMENT, READING LIGHT with the lens
R (4) in the direction of the cabin attendant work-light (3).



EFF :

ALL  33-27-12

Page 414
Feb 01/08
 
IAC 
R (4) Install the lens (4) into the work light housing and remove the TOOL-
R ADJUSTMENT, READING LIGHT.

R (5) Make sure that the work area is clean and clear of tool(s) and other
R items.

R **ON A/C 901-901,

Subtask 33-27-12-860-052-A

A. Put the aircraft back to the serviceable condition.

(1) On the FAP 120RH push the LIGHT MAIN ON/OFF button.

(2) Turn the TOOL-ADJUSTMENT, READING LIGHT counterclockwise to unlock


and remove.

(3) Install the lens (4) into the work light housing.

(4) Make sure that the work area is clean and clear of tool(s) and other
items.

**ON A/C ALL

Subtask 33-27-12-862-051

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-27-12

Page 415
Feb 01/08
 
IAC 
POWER UNIT - CABIN ATTENDANT WORK LIGHT - REMOVAL/INSTALLATION
______________________________________________________________

TASK 33-27-38-000-001

Removal of the Power Unit for the Cabin Attendant Work-Light

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
FOR FIN 3LZ
No specific stepladder 1 m (3 ft. 3 in.)
FOR FIN 12LZ
No specific stepladder 1 m (3 ft. 3 in.)
FOR FIN 13LZ
No specific stepladder 1 m (3 ft. 3 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-27-38-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-27-38-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LIGHT - ATTND WORK 1LZ J05


R

EFF :

001-012, 014-099,  33-27-38

Page 401
Aug 01/07
 
IAC 
R

Subtask 33-27-38-010-050

B. Get Access

(1) FOR 3LZ

(a) Put the stepladder in position below the related panel.

(b) Lower the circuit breaker panel 2000VU.

(2) FOR 12LZ

(a) Put the stepladder in position below the related panel.

(b) Lower the circuit breaker panel 2001VU.

(3) FOR 13LZ

(a) Put the stepladder in position below the related panel.

(b) Disengage and lower one side of the combi panel 2042VU.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-27-38-991-001)

Subtask 33-27-38-020-050

A. Removal of the Power Unit(s) for the Cabin Attendant Work-Lights

(1) Disconnect the electrical connectors (2) and (3).

(2) Put blanking caps on the disconnected electrical connectors.

(3) Removal of the Power Units 3LZ, 12LZ

(a) Remove the screws (5), the washers (6), the nuts (8) and the
power unit (1).

(4) Removal of the Power Unit 13LZ

(a) Remove the screws (5), the washers (6), the spacers (10), and the
power unit (1).


R

EFF :

001-012, 014-099,  33-27-38

Page 402
Aug 01/07
 
IAC 
Power Unit
Figure 401/TASK 33-27-38-991-001


R

EFF :

001-012, 014-099,  33-27-38

Page 403
Aug 01/07
 
IAC 
TASK 33-27-38-400-001

Installation of the Power Unit for the Cabin Attendant Work-Light

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific stepladder 1 m (3 ft. 3 in.)


AMP169994-1 1 CRIMPING DEVICE

B. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

11 cable terminals 33-27-04 10 -020


12 housings 33-27-04 10 -030

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-27-00-710-001 Operational Test of the Cabin Attendant Work-Light


33-27-38-991-001 Fig. 401


R

EFF :

001-012, 014-099,  33-27-38

Page 404
Aug 01/07
 
IAC 
3. __________
Job Set-up

(Ref. Fig. 401/TASK 33-27-38-991-001)

Subtask 33-27-38-910-050

A. Preparation for Installation

(1) Make sure that the related panel is disengaged and lowered.

(2) Make sure that the stepladder is in position below the related panel.

(3) Make the electrical cables (4) shorter if necessary and install the
cable terminals (11) and the housings (12) with the CRIMPING DEVICE.

(4) Clean the component interface and/or the adjacent area.

(5) Do an inspection of the component interface and/or the adjacent area.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-27-38-991-001)

Subtask 33-27-38-420-050

A. Installation of the Power Unit(s) for the Cabin Attendant Work-Light

(1) Installation of the Power Units 3LZ, 12LZ

(a) Put the power unit (1) in position and install with the washers
(6), the screws (5) and the nuts (8).

(b) Remove the blanking caps from the electrical connectors.

(c) Connect the electrical connectors (2) and (3).

(2) Installation of the Power Unit 13LZ

(a) Put the power unit (1) in position and install with the washers
(6), the spacers (10) and the screws (5).

(b) Remove the blanking caps from the electrical connectors.

(c) Connect the electrical connectors (2) and (3).


R

EFF :

001-012, 014-099,  33-27-38

Page 405
Aug 01/07
 
IAC 
Subtask 33-27-38-410-050

B. Close Access

(1) FOR 3LZ

(a) Close the circuit breaker panel 2000VU.

(2) FOR 12LZ

(a) Close the circuit breaker panel 2001VU.

(3) FOR 13LZ

(a) Close and engage the combi panel 2042VU.

Subtask 33-27-38-710-050

C. Test of the Cabin Attendants Work-Lights (Ref. TASK 33-27-00-710-001).

5. Close-up
________

Subtask 33-27-38-410-051

A. Make sure that the work area is clean and clear of tool(s) and other
items.


R

EFF :

001-012, 014-099,  33-27-38

Page 406
Aug 01/07
 
IAC 
_________________________________________________________________________
PISA (PASSENGER INTERFACE AND SUPPLY ADAPTER) - STAND ALONE (203LZ,212LZ)
____________________
REMOVAL/INSTALLATION

TASK 33-27-41-000-001

Removal of the Stand-Alone Passenger Interface and Supply Adapter (StA-PISA)

WARNING : MAKE SURE THAT NO AC OR DC POWER IS CONNECTED TO THE AIRCRAFT


_______
ELECTRICAL CIRCUITS.
THERE IS A RISK OF ELECTROCUTION IF THE AC OR DC POWER STAYS
CONNECTED.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific warning notice(s)
R No specific 1 ACCESS PLATFORM 1M(3 FT)
FOR FIN 203LZ
No specific 1 STEPLADDER 0.5 M (1.6 FT)
FOR FIN 212LZ
No specific 1 STEPLADDER 0.5 M (1.6 FT)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-27-41-991-001 Fig. 401



EFF :

101-199, 901-999,  33-27-41

Page 401
Feb 01/08
 
IAC 
3. __________
Job Set-up

Subtask 33-27-41-010-050

A. Get Access

R (1) Put the ACCESS PLATFORM 1M(3 FT) in position at the access door
121AL.

(2) Open the access door 121AL.

(3) FOR 203LZ

(a) Put the STEPLADDER 0.5 M (1.6 FT) in position below the circuit
breaker panel 2000VU.

(4) FOR 212LZ

(a) Put the STEPLADDER 0.5 M (1.6 FT) in position below the circuit
breaker panel 2001VU.

Subtask 33-27-41-941-050

B. Safety Precautions

(1) Make sure that the external power connector is not connected to the
aircraft EXT PWR receptacle.

(2) Put warning notice(s) in position on the access door 121AL to tell
persons not to connect the external power connector to the aircraft
EXT PWR receptacle.

(3) In the cockpit, on the ELEC panel 35VU, make sure that these
pushbutton switches are released:
- BAT 1, BAT 2,
- APU GEN,
- GEN 1, GEN 2,
- EXT PWR.

(4) In the cockpit, put warning notice(s) in position to tell persons not
to operate the pushbutton switches on these overhead panels:
- 21VU (EMER ELEC PWR section),
- 25VU (APU section),
- 35VU (ELEC).



EFF :

101-199, 901-999,  33-27-41

Page 402
Feb 01/08
 
IAC 
Subtask 33-27-41-865-050

C. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU AIR COND/CIDS/SDF/DIR2 ESS 18WH C06
49VU AIR COND/CIDS/SDF/DIR1 ESS 15WH C05
49VU COM/CIDS/DEU B/ESS 153RH G03
R

R **ON A/C 101-199,

R 49VU COM DIR ESS/2 157RH G02

R **ON A/C 101-199, 901-999,

R 49VU COM/CIDS/DIR ESS/1 150RH G01

R **ON A/C 901-999,

R 49VU COM/CIDS/DIR ESS/2 157RH G02

R **ON A/C 101-199,

R 121VU COM NAV/CIDS/DEU A NORM/R FWD 164RH M11


R 121VU COM NAV/CIDS/DEU A NORM/L FWD 163RH M10
R 121VU COM NAV/CIDS/DIR NORM/2 156RH M07
R 121VU COM NAV/CIDS/DIR NORM/1 151RH M06

R **ON A/C 901-999,

R 121VU COM NAV/CIDS/DEU A NORM/R AFT 168RH M12


R 121VU COM NAV/CIDS/DEU A NORM/L AFT 167RH M11
R 121VU COM NAV/CIDS/DEU A NORM/R FWD 164RH M10
R 121VU COM NAV/CIDS/DEU A NORM/L FWD 163RH M09
R 121VU COM NAV/CIDS/DEU B/NORM 162RH M08
R 121VU COM NAV/CIDS/DIR NORM/2 156RH M06
R 121VU COM NAV/CIDS/DIR NORM/1 151RH M05


R

EFF :

101-199, 901-999,  33-27-41

Page 403
Feb 01/07
 
IAC 
-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R **ON A/C 101-199, 901-999,

R 122VU AIR COND/CIDS/SDF/DIR NORM/2 14WH T18


R 122VU AIR COND/CIDS/SDF/DIR NORM/1 17WH T17
R 122VU ELEC/EXT PWR/LT CLT/NOT IN/USE 6XG X30
R 2000VU LIGHT-ATTND-WORK 1LZ J03

4. Procedure
_________

(Ref. Fig. 401/TASK 33-27-41-991-001)

Subtask 33-27-41-020-050

A. Removal of the Stand Alone Passenger Interface and Supply Adapter


(StA-PISA)

NOTE : The removal procedure for the StA-PISA 203LZ and 212LZ is the
____
same. Only one procedure is given.

(1) Do the subsequent steps to open the related circuit breaker panel:

WARNING : BE VERY CAREFUL WHEN YOU DO WORK ON CIRCUIT BREAKER PANELS.


_______
THERE IS A HIGH VOLTAGE BEHIND THESE PANELS.

(a) Release the quick-release fasteners and lower the related circuit
breaker panel 2000VU or 2001VU carefully. The circuit breaker
panel is held to the adjacent center ceiling panel by a detent
hook.

(b) Release the detent hook and lower one side of the related circuit
breaker panel until it hangs in the vertical position.

(2) Do the subsequent steps to remove the StA-PISA:

(a) Identify the electrical connectors (6, 7 and 8 - if installed)


and make a note of their position before you disconnect them.

(b) Release the related spring latches (4),(5) and (9) and carefully
disconnect the electrical connectors (6, 7 and 8 - if installed)
from the StA-PISA (1).

(c) Put blanking caps on the disconnected electrical connectors.


R

EFF :

101-199, 901-999,  33-27-41

Page 404
Feb 01/07
 
IAC 
Stand Alone Passenger Interface and Supply Adapter (StA PISA)
Figure 401/TASK 33-27-41-991-001


R

EFF :

101-199, 901-999,  33-27-41

Page 405
Feb 01/07
 
IAC 
(d) Make a note of the position of the StA-PISA (1) before you remove
it.

(e) Make a note of the position of the cable clips which keep the
related cable loom in position.

(f) Hold the StA-PISA (1) and remove the screws (2), the washers (3)
and the related cable clips.

(g) Remove the StA-PISA (1).

(h) If you do not install a new StA-PISA directly after the removal,
make sure you close the related circuit breaker panel before you
leave the A/C.


R

EFF :

101-199, 901-999,  33-27-41

Page 406
Feb 01/07
 
IAC 
TASK 33-27-41-400-001

Installation of the Stand-Alone Passenger Interface and Supply Adapter


(StA-PISA)

WARNING : MAKE SURE THAT NO AC OR DC POWER IS CONNECTED TO THE AIRCRAFT


_______
ELECTRICAL CIRCUITS.
THERE IS A RISK OF ELECTROCUTION IF THE AC OR DC POWER STAYS
CONNECTED.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific warning notice


No specific access platform 0.5 m (1 ft. 8 in.)
No specific 1 STEPLADDER 0.5 M (1.6 FT)

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 16-021 F ASNB70720


FLEXIBLE POLYURETHANE (Ref. 20-31-00)


R

EFF :

101-199, 901-999,  33-27-41

Page 407
Feb 01/07
 
IAC 
C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R 23-73-00-740-005 BITE-test of the Cabin Intercommunication Data System


R (CIDS) through the CFDS
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
33-27-41-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-27-41-860-050

A. Aircraft Maintenance Configuration

(1) Make sure that the related circuit breaker panel is disengaged and
lowered.

(2) Make sure that the STEPLADDER 0.5 M (1.6 FT) is below the related
circuit breaker panel.

(3) Make sure that the access platform is in position at the access door
121AL.

(4) Make sure that the access door 121AL is open.

(5) Make sure that the external power connector is not connected to the
aircraft receptacle.

(6) Make sure that a warning notice is in position on the access door
121AL to tell persons not to use the external power receptacle.

(7) In the cockpit, on the overhead ELEC panel 35VU, make sure that these
pushbutton switches are released:
- BAT 1, BAT 2,
- APU GEN,
- GEN 1, GEN 2,
- EXT PWR.



EFF :

101-199, 901-999,  33-27-41

Page 408
Feb 01/08
 
IAC 
(8) In the cockpit, make sure that a warning notice is in position to
tell persons not to operate the pushbutton switches on these overhead
panels:
- 21VU (EMER ELEC PWR),
- 25VU (APU section),
- 35VU (ELEC).

Subtask 33-27-41-865-051

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU AIR COND/CIDS/SDF/DIR2 ESS 18WH C06
49VU AIR COND/CIDS/SDF/DIR1 ESS 15WH C05
49VU COM/CIDS/DEU B/ESS 153RH G03
R

R **ON A/C 101-199,

R 49VU COM DIR ESS/2 157RH G02

R **ON A/C 101-199, 901-999,

R 49VU COM/CIDS/DIR ESS/1 150RH G01

R **ON A/C 901-999,

R 49VU COM/CIDS/DIR ESS/2 157RH G02

R **ON A/C 101-199,

R 121VU COM NAV/CIDS/DEU A NORM/R FWD 164RH M11


R 121VU COM NAV/CIDS/DEU A NORM/L FWD 163RH M10
R 121VU COM NAV/CIDS/DIR NORM/2 156RH M07
R 121VU COM NAV/CIDS/DIR NORM/1 151RH M06

R **ON A/C 901-999,

R 121VU COM NAV/CIDS/DEU A NORM/R AFT 168RH M12


R

EFF :

101-199, 901-999,  33-27-41

Page 409
Feb 01/07
 
IAC 
-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R 121VU COM NAV/CIDS/DEU A NORM/L AFT 167RH M11
R 121VU COM NAV/CIDS/DEU A NORM/R FWD 164RH M10
R 121VU COM NAV/CIDS/DEU A NORM/L FWD 163RH M09
R 121VU COM NAV/CIDS/DEU B/NORM 162RH M08
R 121VU COM NAV/CIDS/DIR NORM/2 156RH M06
R 121VU COM NAV/CIDS/DIR NORM/1 151RH M05

R **ON A/C 101-199, 901-999,

R 122VU AIR COND/CIDS/SDF/DIR NORM/2 14WH T18


R 122VU AIR COND/CIDS/SDF/DIR NORM/1 17WH T17
R 122VU ELEC/EXT PWR/LT CLT/NOT IN/USE 6XG X30
R 2000VU LIGHT-ATTND-WORK 1LZ J03

4. Procedure
_________

(Ref. Fig. 401/TASK 33-27-41-991-001)

Subtask 33-27-41-420-050

A. Installation of the Stand Alone Passenger Interface and Supply Adapter


(StA- PISA)

NOTE : The installation procedure for the StA-PISA 203LZ and 212LZ is the
____
same. Only one procedure is given.

(1) Do the subsequent steps to install the StA-PISA:

WARNING : BE VERY CAREFUL WHEN YOU DO WORK ON CIRCUIT BREAKER PANELS.


_______
THERE IS A HIGH VOLTAGE BEHIND THESE PANELS.

(a) Clean the component interface and/or the adjacent area.

(b) Do an inspection of the component interface and/or the adjacent


area.

(c) Make sure that the ground bonding points of the StA-PISA are free
of paint and corrosion.

(d) Put the StA-PISA (1) in the correct position as recorded in the
removal procedure.


R

EFF :

101-199, 901-999,  33-27-41

Page 410
Feb 01/07
 
IAC 
(e) Make sure the related cable clips are in the correct position on
the cable loom as noted in the removal procedure.

(f) Put the cable clips and the cable loom in position.

(g) Install the screws (2) and the washers (3).

WARNING : OBEY THE MANUFACTURERS INSTRUCTIONS WHEN YOU USE


_______
THIS/THESE MATERIAL/S.
USE PROTECTIVE CLOTHING, RUBBER GLOVES, GOGGLES AND A
MASK.

(h) Apply the STRUCTURE PAINTS (Material No. STRUCTURE PAINTS


(Material No. 16-021)) to the ground bonding points of the
StA-PISA (1).

(i) Remove the blanking caps from the electrical connectors.

(j) Make sure that the electrical connectors are clean and in the
correct condition.

(k) Connect the electrical connectors (6, 7 and 8 - if installed) to


the StA-PISA (1).

(l) Safety the electrical connectors (6, 7 and 8 - if installed).

CAUTION : MAKE SURE THAT THE SPRING LATCHES CORRECTLY HOLD THE
_______
CONNECTOR IN THE FULLY ENGAGED POSITION. THE SPRING
LATCHES PREVENT UNWANTED MOVEMENT OF THE CONNECTOR, AND
THUS THE RISK OF ARCING, WHICH CAN CAUSE DAMAGE TO THE
UNIT.

1
_ Safety the electrical connectors (6, 7 and 8 - if installed)
with the related spring latches (4),(5) and (9).

(2) Do the subsequent steps to close the related circuit breaker panel:

(a) Install the related circuit breaker panel 2000VU or 2001VU with
the detent hook and the quick-release fasteners.

Subtask 33-27-41-865-052

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
6XG, 1LZ, 150RH, 157RH, 153RH, 151RH, 156RH, 162RH, 163RH, 164RH, 167RH,
168RH, 15WH, 18WH, 14WH, 17WH



EFF :

101-199, 901-999,  33-27-41

Page 411
Feb 01/07
 
IAC 
Subtask 33-27-41-740-050

R C. Interface and Power-Up Test of the CIDS

(1) Energize the aircraft electrical circuits


(Ref. TASK 24-41-00-861-002)

R (2) Do the interface and power-up test of the CIDS. (Ref. TASK 23-73-00-
R 740-005)

5. Close-up
________

Subtask 33-27-41-862-050

A. De-energize the aircraft electrical circuits


(Ref. TASK 24-41-00-862-002)

Subtask 33-27-41-410-050

B. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the warning notice(s).

(3) Close the access door 121AL.

(4) Remove the access platform(s).



EFF :

101-199, 901-999,  33-27-41

Page 412
Feb 01/08
 
IAC 
CARGO AND SERVICE COMPARTMENTS - DESCRIPTION AND OPERATION
__________________________________________________________

1. _______
General
The cargo and service compartment lighting-system provides illumination to
the service area, forward and aft cargo compartment, avionics compartment
and wheel wells. A maintenance outlet is installed in the air conditioning
duct and accessory compartment.

2. __________________
System Description

A. Service Area Lighting

**ON A/C 001-012, 014-099,

(Ref. Fig. 001)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 001A)

**ON A/C ALL

The service area lighting comprises the lighting installation of the


equipment compartment in Section 19 and the APU compartment. Electrical
outlets are provided for portable maintenance lights in Section 19. The
lights and outlets are supplied with 28VDC.

B. Air Conditioning Duct and Accessory Compartment

**ON A/C 001-012, 014-099,

(Ref. Fig. 001)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 001A)

**ON A/C ALL

A single outlet is installed for a portable maintenance light. The outlet


is supplied with 28VDC.



EFF :

ALL  33-30-00

Page 1
Feb 01/07
 
IAC 
Service Compartment Lights
Figure 001


R

EFF :

001-012, 014-099,  33-30-00

Page 2
May 01/06
 
IAC 
Service Compartment Lights
Figure 001A


R

EFF :

101-199, 901-999,  33-30-00

Page 3
Feb 01/07
 
IAC 
C. Forward and Aft Cargo-Compartment Lighting

**ON A/C 001-012, 014-099,

(Ref. Fig. 002)

**ON A/C 101-199,

(Ref. Fig. 002A)

**ON A/C 901-999,

(Ref. Fig. 002B)

**ON A/C ALL

The fluorescent lamps illuminate the cargo compartment. They are


installed in the ceiling. A loading light is installed in each
compartment. Electrical outlets are provided for portable maintenance
lights. The fluorescent lamps are supplied with 115VAC, the electrical
outlets and loading lights are supplied with 28VDC.

D. Avionics Compartment Lighting


(Ref. Fig. 003)
The system comprises a number of lights and electrical maintenance
outlets. The lights are supplied with 28VDC. A number of outlets are
supplied with 28VDC and the remainder with 115VAC. The lights may come on
automatically when an equipment bay door is opened. You can also switch
them on with the control switch in the cockpit.

E. Wheel Well Lighting

**ON A/C 001-012, 014-099,

(Ref. Fig. 004)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 004A)



EFF :

ALL  33-30-00

Page 4
May 01/07
 
IAC 
Cargo Compartment Lights
Figure 002


R

EFF :

001-012, 014-099,  33-30-00

Page 5
May 01/06
 
IAC 
R Cargo Compartment Lights
R Figure 002A



EFF :

101-199,  33-30-00

Page 6
Feb 01/07
 
IAC 
Cargo Compartment Lights
R Figure 002B


R

EFF :

901-999,  33-30-00

Page 7
Feb 01/07
 
IAC 
Avionics Compartment Lights
Figure 003


R

EFF :

ALL  33-30-00

Page 8
Feb 01/07
 
IAC 
Wheel Well Lights
Figure 004



EFF :

001-012, 014-099,  33-30-00

Page 9
Feb 01/07
R  
IAC 
R Wheel Well Lights
R Figure 004A


R

EFF :

101-199, 901-999,  33-30-00

Page 10
May 01/07
 
IAC 
R **ON A/C 001-012, 014-099,

R Post SB 92-1032 For A/C 001-012,014-099,

R (Ref. Fig. 004B)

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,


R Post SB 92-1032 For A/C 001-012,014-099,

R (Ref. Fig. 004C)

**ON A/C ALL

The system comprises the lighting installation of the wheel wells and the
hydraulic compartment. Electrical outlets are provided in the wheel wells
for maintenance purposes. A switch in the left-hand wheel well controls
the lights.



EFF :

ALL  33-30-00

Page 11
May 01/07
 
IAC 
Wheel Well Lights
R Figure 004B



EFF :

001-012, 014-099,  33-30-00

Page 12
May 01/07
 
IAC 
R Wheel Well Lights
R Figure 004C



EFF :

001-012, 014-099,  33-30-00

Page 13
May 01/07
 
IAC 
SERVICE AREA LIGHTING - DESCRIPTION AND OPERATION
_________________________________________________

1. _______
General
The service area lighting system comprises the lights installed in the APU
compartment and in Section 19. Electrical outlets are provided for portable
maintenance lights.

2. __________________
Component Location

**ON A/C 001-012, 014-099,

(Ref. Fig. 001)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 001A)

**ON A/C ALL

-------------------------------------------------------------------------------
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
4LJ LIGHT-SERVICE AREA 312 314AL 33-31-00
5LJ LIGHT-SERVICE AREA 311 314AL 33-31-00
6LJ LIGHT-SERVICE AREA 311 315AL 33-31-00
8LJ OUTLET-28 V DC 312 311AL 33-31-00
10LJ OUTLET-28 V DC 312 314AR 33-31-00

3. __________________
System Description

**ON A/C 001-012, 014-099,

(Ref. Fig. 002)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 002A)



EFF :

ALL  33-31-00

Page 1
Feb 01/07
 
IAC 
Service Area Lighting - Component Location
Figure 001


R

EFF :

001-012, 014-099,  33-31-00

Page 2
May 01/06
 
IAC 
Service Area Lighting - Component Location
Figure 001A


R

EFF :

101-199, 901-999,  33-31-00

Page 3
Feb 01/07
 
IAC 
Service Area Lighting - Schematic
Figure 002



EFF :

001-012, 014-099,  33-31-00

Page 4
May 01/06
 
IAC 
Service Area Lighting - Schematic
Figure 002A


R

EFF :

101-199, 901-999,  33-31-00

Page 5
Feb 01/07
 
IAC 
R **ON A/C ALL

The lights and outlets are supplied with 28 V DC from busbar 208PP through
the circuit breakers 2LJ and 1LJ. Switch 11LJ controls the APU light 6LJ and
switch 3LJ controls the two lights 4LJ and 5LJ in Section 19. When busbar
208PP is energized and the circuit breaker 1LJ is closed, power is available
at the two maintenance outlets in Section 19.



EFF :

ALL  33-31-00

Page 6
May 01/06
 
IAC 
SERVICE AREA LIGHTING - ADJUSTMENT/TEST
_______________________________________

TASK 33-31-00-710-001

Operational Test of the Service Area Lighting

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

To make sure that the service area lighting operates correctly.

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific access platform 3 m (9 ft. 10 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

R 3. __________
Job Set-up

Subtask 33-31-00-861-050

A. Energize the aircraft electrical circuit. (Ref. TASK 24-41-00-861-002)



EFF :

ALL  33-31-00

Page 501
May 01/08
 
IAC 
**ON A/C 001-012, 014-019,

Subtask 33-31-00-865-050

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2001VU LIGHT SEC 19 1LJ D07
2001VU LIGHT APU 2LJ D08

**ON A/C 020-099,

Subtask 33-31-00-865-050-A

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2001VU LIGHT SEC 19 1LJ F05
2001VU LIGHT APU 2LJ F06

**ON A/C 101-199, 901-999,

Subtask 33-31-00-865-050-B

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2001VU LIGHT SEC 19 1LJ E07
2001VU LIGHT APU 2LJ E08



EFF :

ALL  33-31-00

Page 502
May 01/08
R  
IAC 
**ON A/C ALL

Subtask 33-31-00-010-050

C. Get Access

(1) Put the access platform in position:


FOR 4LJ, 5LJ
in Zone 312.
FOR 6LJ
below the APU compartment.

(2) Open the access door:


FOR 4LJ, 5LJ
open 312AR.
FOR 6LJ
open 315AL.

4. Procedure
_________

Subtask 33-31-00-710-050

A. Test of the Service Area Lighting.

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. In the section 19 service area: In the section 19 service area:

- set the control switch 3LJ to - the service area lights 4LJ and 5LJ
the ON position. come on.

- set the control switch 3LJ to - the service area lights 4LJ and 5LJ
the OFF position. go off.

2. In the APU compartment: In the APU compartment:

- set the control switch 11LJ to - the service area light 6LJ comes on.
the ON position.

- set the control switch 11LJ to - the service area light 6LJ goes off.
the OFF position.



EFF :

ALL  33-31-00

Page 503
May 01/08
R  
IAC 
R 5. Close-up
________

Subtask 33-31-00-410-050

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Close the access door:


FOR 4LJ, 5LJ
close 312AR.
FOR 6LJ
close 315AL.

(3) Remove the access platform(s).

Subtask 33-31-00-862-050

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-31-00

Page 504
May 01/08
 
IAC 
TASK 33-31-00-720-001

Functional Test of the Maintenance Sockets

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

To make sure that the maintenance sockets operate correctly.

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific multimeter
No specific access platform 3 m (9 ft. 10 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

R 3. __________
Job Set-up

Subtask 33-31-00-861-051

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-31-00-865-051

B. Make sure that this(these) circuit breaker(s) is(are) closed:


1LJ.



EFF :

ALL  33-31-00

Page 505
May 01/08
 
IAC 
Subtask 33-31-00-010-052

C. Get Access

(1) Put the access platform in position in Zone 314.

(2) Open the access door 314AR.

4. Procedure
_________

Subtask 33-31-00-860-050

A. Preparation for the Test.

(1) Use the multimeter for this test.

Subtask 33-31-00-720-050

B. Test of the Maintenance Sockets.

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the electrical panel 2025VU: On the multimeter:

- measure the output voltage - the output voltage is 28V DC.


between the connections + and N
on the maintenance sockets 8LJ
and 10LJ.

R 5. Close-up
________

Subtask 33-31-00-410-051

A. Close Access

(1) Remove the multimeter.

(2) Make sure that the work area is clean and clear of tool(s) and other
items.

(3) Close the access door 314AR.

(4) Remove the access platform(s).



EFF :

ALL  33-31-00

Page 506
May 01/08
 
IAC 
Subtask 33-31-00-862-051

B. De-energize the aircraft electrical circuit (Ref. TASK 24-41-00-862-002).



EFF :

ALL  33-31-00

Page 507
Feb 01/96
 
IAC 
LIGHT - SERVICE AREA - REMOVAL/INSTALLATION
___________________________________________

TASK 33-31-11-000-001

Removal of the Service Area Light 6LJ

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific access platform 3.2 m (10 ft. 6 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-099,

33-31-11-991-001 Fig. 401

R **ON A/C 101-199, 901-999,

33-31-11-991-001-A Fig. 401A



EFF :

ALL  33-31-11

Page 401
Feb 01/07
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

**ON A/C 001-012, 014-099,

Subtask 33-31-11-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2001VU LIGHT APU 2LJ D08
121VU APU/ECB/SPLY 1KD L41
121VU APU/APU/CTL 2KD L42

R **ON A/C 101-199, 901-999,

Subtask 33-31-11-865-050-A

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2001VU LIGHT APU 2LJ E08
121VU APU/ECB/SPLY 1KD L41
121VU APU/APU/CTL 2KD L42

**ON A/C ALL

Subtask 33-31-11-010-050

B. Get Access

(1) Put the access platform in position below the APU compartment.

WARNING : LOCK THE MECHANISM OF THE ACCESS DOOR 316AR WITH THE PIP
_______
PIN WHEN YOU OPEN THE ACCESS DOOR. THIS WILL PREVENT
INJURY.

(2) Open the APU access doors 315AL, 316AR.



EFF :

ALL  33-31-11

Page 402
Feb 01/07
 
IAC 
(3) Put the switch 11LJ at Zone 315 in the OFF position.

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-31-11-991-001)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-31-11-991-001-A)

**ON A/C 001-012, 014-099,

Subtask 33-31-11-020-050

A. Removal of the Service Area Light and the Lamp

(1) Removal of the Lamp

(a) Remove the screws (12), the grid-screen (7), the lens (8) and the
seal (9) from the housing (11).

(b) Remove the lamp (10).

(2) Removal of the Service Area Light

(a) Remove the screws (6), the washers (5) and hold the service area
light (4) to get access to the electrical connectors (1).

(b) Remove the nuts (3), the washers (2) and the electrical
connectors (1).

(c) Put blanking caps on the disconnected electrical connectors.

(d) Remove the service area light (4).



EFF :

ALL  33-31-11

Page 403
Feb 01/07
 
IAC 
Service Area Light
Figure 401/TASK 33-31-11-991-001


R

EFF :

001-012, 014-099,  33-31-11

Page 404
May 01/06
 
IAC 
Service Area Light
Figure 401A/TASK 33-31-11-991-001-A


R

EFF :

101-199, 901-999,  33-31-11

Page 405
Feb 01/07
 
IAC 
R **ON A/C 101-199, 901-999,

Subtask 33-31-11-020-050-A

A. Removal of the Service Area Light

(1) Remove the screws (4) with the washers (5) and hold the service area
light (1) to get access to the electrical connectors (2) and (3).

(2) Disconnect the electrical connectors (2) and (3).

(3) Put blanking caps on the disconnected electrical connectors.

(4) Remove the service area light (1).


R

EFF :

101-199, 901-999,  33-31-11

Page 406
Feb 01/07
 
IAC 
**ON A/C ALL

TASK 33-31-11-400-001

Installation of the Service Area Light 6LJ

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific 1 ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R Material No. 05-002 USA MIL-PRF-8116


PUTTY, ZINC CHROMATE GENERAL PURPOSE (Ref. 20-31-00)
Material No. 09-003 C Z-16.115
SEALANT,POLYSULFIDE (USE 09-018) (Ref. 20-31-00)



EFF :

ALL  33-31-11

Page 407
Feb 01/08
 
IAC 
C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-31-00-710-001 Operational Test of the Service Area Lighting

**ON A/C 001-012, 014-099,

33-31-11-991-001 Fig. 401

R **ON A/C 101-199, 901-999,

33-31-11-991-001-A Fig. 401A

**ON A/C ALL

3. __________
Job Set-up

**ON A/C 001-012, 014-099,

Subtask 33-31-11-865-051

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2001VU LIGHT APU 2LJ D08
121VU APU/ECB/SPLY 1KD L41
121VU APU/APU/CTL 2KD L42



EFF :

ALL  33-31-11

Page 408
Feb 01/07
 
IAC 
R **ON A/C 101-199, 901-999,

Subtask 33-31-11-865-051-A

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2001VU LIGHT APU 2LJ E08
121VU APU/ECB/SPLY 1KD L41
121VU APU/APU/CTL 2KD L42

Subtask 33-31-11-860-050

B. Aircraft Maintenance Configuration

(1) Make sure, that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in
position below the APU doors.

(2) Make sure, that the APU doors are open.

WARNING : LOCK THE MECHANISM OF THE ACCESS DOOR 316AR WITH THE PIP
_______
PIN WHEN YOU OPEN THE ACCESS DOOR. THIS WILL PREVENT
INJURY.

(a) Make sure, that the APU doors 315AL and 316AR are open.

(3) Make sure, that the switch 11LJ at zone 315 is in the OFF position.

**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-31-11-991-001)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-31-11-991-001-A)



EFF :

ALL  33-31-11

Page 409
Feb 01/07
 
IAC 
R **ON A/C 001-012, 014-099,

Subtask 33-31-11-910-050

A. Preparation for Installation

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Apply the SEALANTS (Material No. 09-003) to the mating surface of the
service area light (4).

(4) Apply the SPECIAL MATERIALS (Material No. 05-002) to the washers (5)
and the screws (6).

Subtask 33-31-11-420-051

B. Installation of the Service Area Light and the Lamp

(1) Remove the blanking caps from the electrical connectors.

(2) Make sure that the electrical connectors are clean and in the correct
condition.

(3) Install the lamp (10) in the housing (11).

(4) Put the the seal (9) in position on the housing (11) and align the
screw holes.

(5) Put the lens (8) in position on the seal (9).

(6) Put the grid-screen in position over the lens (8), align the screw
holes and install the screws (12).

(7) Hold the service area light (4) adjacent to its correct installation
position.

(8) Put the electrical connectors (1) on the terminals of the service
area light (4) and install the washers (2) and the nuts (3).

(9) Put the service area light (4) in its correct installation position,
align the screw holes, install the screws (6) and the washers (5).


R

EFF :

001-012, 014-099,  33-31-11

Page 410
May 01/06
 
IAC 
R **ON A/C 101-199, 901-999,

Subtask 33-31-11-910-050-A

A. Preparation for Installation

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Apply the SPECIAL MATERIALS (Material No. 05-002) to the washers (5)
and the screws (4).

Subtask 33-31-11-420-051-A

B. Installation of the Service Area Light

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED
_______
BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

(1) Remove the blanking caps from the electrical connectors.

(2) Make sure that the electrical connectors are clean and in the correct
condition.

(3) Connect and secure the electrical connectors (2) and (3).

(4) Put the service area light (1) in the correct installation position
at the structure (6).

(5) Install the washers (5) and the screws (4) and tighten.

Subtask 33-31-11-865-062

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
2LJ, 1KD, and 2KD

**ON A/C ALL

Subtask 33-31-11-710-050

D. Do the operational test of the service area light (Ref. TASK 33-31-00-
710-001).



EFF :

ALL  33-31-11

Page 411
Feb 01/07
 
IAC 
5. Close-up
________

Subtask 33-31-11-410-050

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Close the APU access doors 315AL, 316AR.

(3) Remove the access platform(s).



EFF :

ALL  33-31-11

Page 412
May 01/06
R  
IAC 
TASK 33-31-11-000-002

Removal of the Service Area Light 4LJ (5LJ)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific access platform 3.0 m (9 ft. 10 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-099,

33-31-11-991-002 Fig. 402

R **ON A/C 101-199, 901-999,

33-31-11-991-002-A Fig. 402A



EFF :

ALL  33-31-11

Page 413
Feb 01/07
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

**ON A/C 001-012, 014-099,

Subtask 33-31-11-865-052

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2001VU LIGHT SEC 19 1LJ D07

R **ON A/C 101-199, 901-999,

Subtask 33-31-11-865-052-A

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2001VU LIGHT SEC 19 1LJ E07

**ON A/C ALL

Subtask 33-31-11-010-051

B. Get Access

(1) Put a warning notice in the cockpit to tell persons not to operate
the flight controls.

(2) Put the access platform in position in the Zone 312.

(3) Open the access door 312AR.

(4) Put the switch 3LJ at Zone 312 in the OFF position.



EFF :

ALL  33-31-11

Page 414
Feb 01/07
 
IAC 
4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 402/TASK 33-31-11-991-002)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 402A/TASK 33-31-11-991-002-A)

**ON A/C 001-012, 014-099,

Subtask 33-31-11-020-051

A. Removal of the Service Area Light and the Lamp

(1) Removal of the Lamp

(a) Remove the screws (12), the grid-screen (7), the lens (8) and the
seal (9) from the housing (11).

(b) Remove the lamp (10).

(2) Removal of the Service Area Light

(a) Remove the screws (6), the washers (5) and hold the service area
light (4) to get access to the electrical connections (1).

(b) Remove the nuts (3), the washers (2) and the electrical
connections (1).

(c) Put blanking caps on the disconnected electrical connectors.

(d) Remove the service area light (4).



EFF :

ALL  33-31-11

Page 415
Feb 01/07
 
IAC 
Service Area Light
Figure 402/TASK 33-31-11-991-002



EFF :

001-012, 014-099,  33-31-11

Page 416
May 01/06
 
IAC 
Service Area Light
Figure 402A/TASK 33-31-11-991-002-A


R

EFF :

101-199, 901-999,  33-31-11

Page 417
Feb 01/07
 
IAC 
R **ON A/C 101-199, 901-999,

Subtask 33-31-11-020-051-A

A. Removal of the Service Area Light

(1) Remove the screws (1) with the washers (2) and hold the service area
light (3) to get access to the electrical connectors (5) an (6).

(2) Disconnect the electrical connectors (5) and (6).

(3) Put blanking caps on the disconnected electrical connectors.

(4) Remove the service area light (3).


R

EFF :

101-199, 901-999,  33-31-11

Page 418
Feb 01/07
 
IAC 
**ON A/C ALL

TASK 33-31-11-400-002

Installation of the Service Area Light 4LJ (5LJ)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific 1 ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R Material No. 05-002 USA MIL-PRF-8116


PUTTY, ZINC CHROMATE GENERAL PURPOSE (Ref. 20-31-00)
Material No. 09-003 C Z-16.115
SEALANT,POLYSULFIDE (USE 09-018) (Ref. 20-31-00)

C. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

9 seal 33-31-11 01 -030



EFF :

ALL  33-31-11

Page 419
Feb 01/08
 
IAC 
D. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-31-00-710-001 Operational Test of the Service Area Lighting

**ON A/C 001-012, 014-099,

33-31-11-991-002 Fig. 402

R **ON A/C 101-199, 901-999,

33-31-11-991-002-A Fig. 402A

**ON A/C ALL

3. __________
Job Set-up

**ON A/C 001-012, 014-099,

Subtask 33-31-11-865-053

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2001VU LIGHT SEC 19 1LJ D07

R **ON A/C 101-199, 901-999,

Subtask 33-31-11-865-053-A

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2001VU LIGHT SEC 19 1LJ E07



EFF :

ALL  33-31-11

Page 420
Feb 01/07
 
IAC 
Subtask 33-31-11-860-051

B. Aircraft Maintenance Configuration

(1) Make sure, that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in
position below the access door at zone 312.

(2) Make sure, that the access door 312AR is open.

(3) Make sure, that the switch 3LJ at zone 312 is in the OFF position.

**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 402/TASK 33-31-11-991-002)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 402A/TASK 33-31-11-991-002-A)

**ON A/C 001-012, 014-099,

Subtask 33-31-11-910-051

A. Preparation for Installation

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Apply the SEALANTS (Material No. 09-003) to the mating surface of the
service area light (4).

(4) Apply the SPECIAL MATERIALS (Material No. 05-002) to the washers (5)
and the screws (6).



EFF :

ALL  33-31-11

Page 421
Feb 01/07
 
IAC 
Subtask 33-31-11-420-052

B. Installatiom of the Service Area LIght and the Lamp

(1) Installation of the Lamp

(a) Install the lamp (10) in the housing (11).

(b) Install the new seal (9) ,the lens (8) and the grid-screen (7)
with the screws (12) on the housing (11).

(2) Installation of the Service Area Light

(a) Remove the blanking caps from the electrical connectors.

(b) Hold the service area light (4) and install the electrical
connections (1) with the washers (2) and the nuts (3).

(c) Install the service area light (4) with the washers (2) and the
screws (6).

R **ON A/C 101-199, 901-999,

Subtask 33-31-11-910-051-A

A. Preparation for Installation

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Apply the SPECIAL MATERIALS (Material No. 05-002) to the screws (1)
and the washers (2).

Subtask 33-31-11-420-052-A

B. Installation of the Service Area Light

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED
_______
BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

(1) Remove the blanking caps from the electrical connectors.

(2) Make sure that the electrical connectors are clean and in the correct
condition.



EFF :

ALL  33-31-11

Page 422
Feb 01/07
 
IAC 
R (3) Connect and secure the electrical connectors (5) and (6).

R (4) Put the service area light (3) in the correct installation position
R at the structure (4).

R (5) Install the washers (2) and the screws (1) and tighten.

R Subtask 33-31-11-865-063

R C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
R breaker(s):
R 1LJ

R **ON A/C ALL

Subtask 33-31-11-710-051

R D. Do the operational test of the service area light (Ref. TASK 33-31-00-
710-001).

5. Close-up
________

Subtask 33-31-11-410-052

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Close the access door 312AR.

(3) Remove the access platform(s).



EFF :

ALL  33-31-11

Page 423
May 01/06
 
IAC 
R **ON A/C 101-199, 901-999,

TASK 33-31-11-000-003

Removal of the Lamp of the Service Area Light 6LJ

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific 1 ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-31-11-991-003 Fig. 403

3. __________
Job Set-up

Subtask 33-31-11-865-054

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2001VU LIGHT APU 2LJ E08
121VU APU/ECB/SPLY 1KD L41
121VU APU/APU/CTL 2KD L42


R

EFF :

101-199, 901-999,  33-31-11

Page 424
Feb 01/07
 
IAC 
Subtask 33-31-11-010-052

B. Get Access

(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the
APU compartment.

(2) Open the APU access doors.

WARNING : LOCK THE MECHANISM OF THE ACCESS DOOR 316AR WITH THE PIP
_______
PIN WHEN YOU OPEN THE ACCESS DOOR. THIS WILL PREVENT
INJURY.

(a) Open the APU access doors 315AL, 316AR.

(3) Set the switch 11LJ at zone 315 to the OFF position.

4. Procedure
_________

(Ref. Fig. 403/TASK 33-31-11-991-003)

Subtask 33-31-11-020-052

A. Removal of the Lamp of the Service Area Light

(1) Loosen the captive screws (3).

(2) Remove the cover assembly (4) from the housing (1).

NOTE : The lens is bonded in the cover assembly and cannot be


____
replaced.

(3) Remove the lamp (5) from the light assembly (2) and discard the lamp.


R

EFF :

101-199, 901-999,  33-31-11

Page 425
Feb 01/07
 
IAC 
Service Area Light
Figure 403/TASK 33-31-11-991-003


R

EFF :

101-199, 901-999,  33-31-11

Page 426
Feb 01/07
 
IAC 
TASK 33-31-11-400-003

Installation of the Lamp of the Service Area Light 6LJ

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific 1 ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R Material No. 05-002 USA MIL-PRF-8116


PUTTY, ZINC CHROMATE GENERAL PURPOSE (Ref. 20-31-00)

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-31-00-710-001 Operational Test of the Service Area Lighting


33-31-11-991-003 Fig. 403



EFF :

101-199, 901-999,  33-31-11

Page 427
Feb 01/08
 
IAC 
3. __________
Job Set-up

Subtask 33-31-11-865-055

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2001VU LIGHT APU 2LJ E08
121VU APU/ECB/SPLY 1KD L41
121VU APU/APU/CTL 2KD L42

Subtask 33-31-11-860-052

B. Aircraft Maintenance Configuration

(1) Make sure, that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in
position below the APU doors.

(2) Make sure, that the APU access doors are open.

WARNING : LOCK THE MECHANISM OF THE ACCESS DOOR 316AR WITH THE PIP
_______
PIN WHEN YOU OPEN THE ACCESS DOOR. THIS WILL PREVENT
INJURY.

(a) Make sure, that the APU doors 315AL and 316AR are open.

(3) Make sure, that the switch 11LJ at zone 315 is in the OFF position.

4. Procedure
_________

(Ref. Fig. 403/TASK 33-31-11-991-003)

Subtask 33-31-11-910-052

A. Preparation for Installation

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Apply the SPECIAL MATERIALS (Material No. 05-002) to the captive
screws (3).


R

EFF :

101-199, 901-999,  33-31-11

Page 428
Feb 01/07
 
IAC 
Subtask 33-31-11-420-053

B. Installation of the Lamp of the Service Area Light

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED
_______
BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.

NOTE : When it is necessary to replace one lamp, it is recommended that


____
you replace the second lamp at the same time.

(1) Put the lamp (5) in the light assembly (2) and turn it clockwise to
lock the lamp in position.

(2) Correctly align the cover assembly (4) with the screw holes of the
housing (1).

(3) Install the captive screws (3) and tighten.

Subtask 33-31-11-865-064

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
2LJ, 1KD, 2KD

Subtask 33-31-11-710-052

D. Do the operational test of the service area light (Ref. TASK 33-31-00-
710-001).

5. Close-up
________

Subtask 33-31-11-410-054

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Close the APU access doors 315AL, 316AR.

(3) Remove the access platform(s).


R

EFF :

101-199, 901-999,  33-31-11

Page 429
Feb 01/07
 
IAC 
TASK 33-31-11-000-004

Removal of the Lamp of the Service Area Light 4LJ (5LJ)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific 1 ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-31-11-991-004 Fig. 404

3. __________
Job Set-up

Subtask 33-31-11-865-056

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2001VU LIGHT SEC 19 1LJ E07

Subtask 33-31-11-010-053

B. Get Access

(1) Put a warning notice in the cockpit to tell persons not to operate
the flight controls.

(2) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at zone
312.


R

EFF :

101-199, 901-999,  33-31-11

Page 430
Feb 01/07
 
IAC 
(3) Open the access door 312AR

(4) Set the switch 3LJ at zone 312 to the OFF position.

4. Procedure
_________

(Ref. Fig. 404/TASK 33-31-11-991-004)

Subtask 33-31-11-020-053

A. Removal of the Lamp of the Service Area Light

(1) Loosen the captive screws (5).

(2) Remove the cover assembly (4) from the housing (1).

NOTE : The lens is bonded in the cover assembly and cannot be


____
replaced.

(3) Remove the lamp (3) from the light assembly (2) and discard the lamp.


R

EFF :

101-199, 901-999,  33-31-11

Page 431
Feb 01/07
 
IAC 
Service Area Light
Figure 404/TASK 33-31-11-991-004


R

EFF :

101-199, 901-999,  33-31-11

Page 432
Feb 01/07
 
IAC 
TASK 33-31-11-400-004

Installation of the Lamp of the Service Area Light 4LJ (5LJ)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific 1 ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R Material No. 05-002 USA MIL-PRF-8116


PUTTY, ZINC CHROMATE GENERAL PURPOSE (Ref. 20-31-00)

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-31-00-710-001 Operational Test of the Service Area Lighting


33-31-11-991-004 Fig. 404

3. __________
Job Set-up

Subtask 33-31-11-865-057

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2001VU LIGHT SEC 19 1LJ E07



EFF :

101-199, 901-999,  33-31-11

Page 433
Feb 01/08
 
IAC 
Subtask 33-31-11-860-053

B. Aircraft Maintenance Configuration

(1) Make sure, that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in
position below the access door at zone 312.

(2) Make sure, that the access door 312AR is open.

(3) Make sure, that the switch 3LJ at zone 312 is in the OFF position.

4. Procedure
_________

(Ref. Fig. 404/TASK 33-31-11-991-004)

Subtask 33-31-11-910-053

A. Preparation for Installation

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Apply the SPECIAL MATERIALS (Material No. 05-002) to the captive
screws (5).

Subtask 33-31-11-420-054

B. Installation of the Lamp of the Service Area Light

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED
_______
BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.

NOTE : When it is necessary to replace one lamp, it is recommended that


____
yoè replace the second lamp at the same time.

(1) Put the lamp (3) in the light assembly (2) and turn it clockwise to
lock the lamp in position.

(2) Correctly align the cover assembly (4) with the screw holes of the
housing (1).


R

EFF :

101-199, 901-999,  33-31-11

Page 434
Feb 01/07
 
IAC 
(3) Install the captive screws (5) and tighten.

Subtask 33-31-11-865-065

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LJ

Subtask 33-31-11-710-053

D. Do the operational test of the service area light (Ref. TASK 33-31-00-
710-001).

5. Close-up
________

Subtask 33-31-11-410-055

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Close the access door 312AR.

(3) Remove the access platform(s).


R

EFF :

101-199, 901-999,  33-31-11

Page 435
Feb 01/07
 
IAC 
________________________________________________________
AIR CONDITIONING DUCT AND ACCESSORY COMPARTMENT LIGHTING
DESCRIPTION AND OPERATION
_________________________

1. _______
General
The air conditioning compartment is provided with an electrical outlet for a
portable maintenance light.

2. Component
__________________
Location
(Ref. Fig. 001)

-------------------------------------------------------------------------------
FIN FUNCTIONAL DESIGNATION PANEL ZONE ACCESS
DOOR
-------------------------------------------------------------------------------
2LK OUTLET - 28 V DC 138

3. System
__________________
Description
(Ref. Fig. 002)
The electrical outlet is supplied from the 28 V DC busbar 208PP. When the
busbar is energized and the circuit breaker 1LK is closed, power is
available at the maintenance outlet 2LK. The outlet is designed for use up
to a maximum of 50 Watts.



EFF :

ALL  33-32-00

Page 1
Feb 01/96
 
IAC 
R Air Conditioning Duct and Accessory Compartment Lighting - Component Location
Figure 001



EFF :

ALL  33-32-00

Page 2
Aug 01/96
 
IAC 
Air Conditioning Duct and Accessory Compartment Lighting - Schematic
Figure 002



EFF :

ALL  33-32-00

Page 3
Feb 01/96
 
IAC 
AIR CONDITIONING DUCT AND ACCESSORY COMPARTMENT LIGHTING - ADJUSTMENT/TEST
__________________________________________________________________________

TASK 33-32-00-720-001

Functional Test of the Maintenance Socket in the Air Conditioning Duct and
Accessory Compartment (LK)

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

To make sure that the maintenance socket operates correctly.

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific multimeter

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-32-00-861-050

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).



EFF :

ALL  33-32-00

Page 501
May 01/06
R  
IAC 
**ON A/C 001-012, 014-099,

Subtask 33-32-00-865-050

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU AIR CONDTN COMPT OUTLET 1LK B08

R **ON A/C 101-199, 901-999,

Subtask 33-32-00-865-050-A

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU AIR CONDTN COMPT OUTLET 1LK G08

**ON A/C ALL

Subtask 33-32-00-010-050

C. Get Access

(1) Open the access panel 192FB.

(2) Use the multimeter for this test.



EFF :

ALL  33-32-00

Page 502
Feb 01/07
 
IAC 
4. Procedure
_________

Subtask 33-32-00-720-050

A. Test of the Maintenance Socket

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. In the Air conditioning duct and


accessory compartment:

On the multimeter:

- measure the output voltage - the output voltage is 28 V DC.


between the connections + and N
on the maintenance socket 2LK.

5. Close-up
________

Subtask 33-32-00-410-050

A. Close Access

(1) Remove the multimeter.

(2) Close the access panel 192FB.

Subtask 33-32-00-862-050

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-32-00

Page 503
May 01/06
R  
IAC 
FWD - AFT CARGO COMPARTMENT LIGHTING - DESCRIPTION AND OPERATION
________________________________________________________________

1. _______
General
The fluorescent lamps, which are installed in the ceiling, illuminate the
forward and aft cargo compartments. Each fluorescent lamp is installed in a
lampholder which includes the ballast unit.
A loading area light is installed in each of the loading areas.

2. __________________
Component Location

R **ON A/C 001-012, 014-099,

(Ref. Fig. 001)

-------------------------------------------------------------------------------
FIN FUNCTIONAL DESIGNATION PANEL ZONE ACCESS ATA
DOOR REF.
-------------------------------------------------------------------------------
6LU SWITCH - FWD CARGO COMPT. 132
7LU SWITCH - FWD LOADING AREA 132
8LU SWITCH - AFT CARGO COMPT. 2024VU 152
9LU SWITCH - AFT LOADING AREA 2024VU 152
11LU LOADING AREA LIGHT FWD 132
12LU LOADING AREA LIGHT AFT 152
13LU BALLAST UNIT 130 33-34-11
13LU-1 FLUORESCENT LAMP 130 33-34-11
14LU BALLAST UNIT 130 33-34-11
14LU-1 FLUORESCENT LAMP 130 33-34-11
15LU BALLAST UNIT 150 33-34-11
15LU-1 FLUORESCENT LAMP 150 33-34-11
16LU BALLAST UNIT 150 33-34-11
16LU-1 FLUORESCENT LAMP 150 33-34-11
17LU BALLAST UNIT 150 33-34-11
17LU-1 FLUORESCENT LAMP 150 33-34-11



EFF :

ALL  33-34-00

Page 1
May 01/06
 
IAC 
FWD and AFT Cargo Compartment Lighting - Component Location
Figure 001


R

EFF :

001-012, 014-099,  33-34-00

Page 2
May 01/06
 
IAC 
R **ON A/C 101-199,

R (Ref. Fig. 001A)

R -------------------------------------------------------------------------------
R FIN FUNCTIONAL DESIGNATION PANEL ZONE ACCESS ATA
R DOOR REF.
R -------------------------------------------------------------------------------
R 6LU SWITCH - FWD CARGO COMPT. 132
R 7LU SWITCH - FWD LOADING AREA 132
R 8LU SWITCH - AFT CARGO COMPT. 2024VU 152
R 9LU SWITCH - AFT LOADING AREA 2027VU 152
R 11LU LOADING AREA LIGHT FWD 132
R 12LU LOADING AREA LIGHT AFT 152
R 13LU BALLAST UNIT 130 33-34-11
R 13LU-1 FLUORESCENT LAMP 130 33-34-11
R 14LU BALLAST UNIT 130 33-34-11
R 14LU-1 FLUORESCENT LAMP 130 33-34-11
R 15LU BALLAST UNIT 150 33-34-11
R 15LU-1 FLUORESCENT LAMP 150 33-34-11
R 16LU BALLAST UNIT 150 33-34-11
R 16LU-1 FLUORESCENT LAMP 150 33-34-11
R 17LU BALLAST UNIT 160 33-34-11
R 17LU-1 FLUORESCENT LAMP 160 33-34-11
R 18LU SWITCH - AFT CARGO COMPT. 160
R 20LU BALLAST UNIT 130 33-34-11
R 20LU-1 FLUORESCENT LAMP 130 33-34-11
R 21LU BALLAST UNIT 130 33-34-11
R 21LU-1 FLUORESCENT LAMP 130 33-34-11
R 22LU BALLAST UNIT 150 33-34-11
R 22LU-1 FLUORESCENT LAMP 150 33-34-11


R

EFF :

101-199,  33-34-00

Page 3
Feb 01/07
 
IAC 
FWD and AFT Cargo Compartment Lighting - Component Location
Figure 001A


R

EFF :

101-199, 901-999,  33-34-00

Page 4
Feb 01/07
 
IAC 
R **ON A/C 901-999,

(Ref. Fig. 001A)

-------------------------------------------------------------------------------
FIN FUNCTIONAL DESIGNATION PANEL ZONE ACCESS ATA
DOOR REF.
-------------------------------------------------------------------------------
6LU SWITCH - FWD CARGO COMPT. 132
7LU SWITCH - FWD LOADING AREA 132
8LU SWITCH - AFT CARGO COMPT. 2024VU 152
9LU SWITCH - AFT LOADING AREA 2027VU 152
11LU LOADING AREA LIGHT FWD 132
12LU LOADING AREA LIGHT AFT 152
13LU BALLAST UNIT 130 33-34-11
13LU-1 FLUORESCENT LAMP 130 33-34-11
15LU BALLAST UNIT 150 33-34-11
15LU-1 FLUORESCENT LAMP 150 33-34-11
16LU BALLAST UNIT 150 33-34-11
16LU-1 FLUORESCENT LAMP 150 33-34-11
17LU BALLAST UNIT 160 33-34-11
17LU-1 FLUORESCENT LAMP 160 33-34-11

**ON A/C ALL

3. __________________
System Description

**ON A/C 001-012, 014-099,

(Ref. Fig. 002)


The ceiling lights are installed on crossbeams of the forward and aft cargo
compartments. The loading area lights are bracket mounted and the light
direction is adjustable.

The 115VAC from busbar 214XPA supplies the ceiling lamps 13LU-1 and 14LU-1
of the forward cargo compartment through circuit breaker 1LU. The toggle
switch 6LU controls the ballast units of these ceiling lamps.

The 115VAC from busbar 214XPB supplies the aft cargo compartment ceiling
lamps 15LU-1, 16LU-1 and 17LU-1 through the circuit breaker 2LU. The toggle
switch 8LU controls the ballast units of these ceiling lamps.

The 28VDC busbar 602PP supplies the forward loading-area light through the
circuit breaker 3LU and the toggle switch 7LU.


R

EFF :

ALL  33-34-00

Page 5
Feb 01/07
 
IAC 
The 28VDC busbar 602PP supplies the aft loading-area light through the
circuit breaker 3LU and toggle switch 9LU.

R **ON A/C 101-199,

R (Ref. Fig. 002A)


R The ceiling lights are installed on crossbeams in the forward and aft cargo
R compartments. The loading area lights are bracket mounted and the light
R direction is adjustable.
R
R The 115VAC busbar 214XPA supplies the ceiling lamps 13LU-1, 14LU-1, 20LU-1
R and 21LU-1 of the forward cargo compartment through the circuit breaker 1LU.
R The toggle switch 6LU controls the ballast units of these ceiling lamps.
R
R The 115VAC busbar 214XPB supplies the ceiling lamps 15LU-1, 16LU-1, 17LU-1
R and 22LU-1 of the aft cargo compartment through the circuit breaker 2LU.
R The toggle switch 8LU controls the ballast units of the ceiling lamps
R 15LU-1, 16LU-1 and 22LU-1.
R The toggle switch 18LU controls the ballast unit of the ceiling lamp 17LU-1.
R
R The 28VDC busbar 602PP supplies the forward loading-area light through the
R circuit breaker 3LU and the toggle switch 7LU.
R
R The 28VDC busbar 602PP supplies the aft loading-area light through the
R circuit breaker 3LU and the toggle switch 9LU.

R **ON A/C 901-999,

(Ref. Fig. 002A)


The ceiling lights are installed on crossbeams in the forward and aft cargo
compartments. The loading area lights are bracket mounted and the light
direction is adjustable.

The 115VAC busbar 214XPA supplies the ceiling lamp 13LU-1 of the forward
cargo compartment through the circuit breaker 1LU. The toggle switch 6LU
controls the ballast unit of this ceiling lamp.

The 115VAC busbar 214XPB supplies the ceiling lamps 15LU-1, 16LU-1 and
17LU-1 of the aft cargo compartment through the circuit breaker 2LU. The
toggle switch 8LU controls the ballast units of these ceiling lamps.

The 28VDC busbar 602PP supplies the forward loading-area light 11LU through
the circuit breaker 3LU and the toggle switch 7LU.



EFF :

ALL  33-34-00

Page 6
Feb 01/07
 
IAC 
FWD and AFT Cargo Compartment Lighting - Schematic
Figure 002


R

EFF :

001-012, 014-099,  33-34-00

Page 7/8
Feb 01/07
 
IAC 
INTENTIONALLY BLANK


R



 33-34-00

Page 9
Feb 01/07
 
IAC 
FWD and AFT Cargo Compartment Lighting - Schematic
Figure 002A (SHEET 1)



EFF :

101-199, 901-999,  33-34-00

Page 10
Feb 01/07
 
IAC 
FWD and AFT Cargo Compartment Lighting - Schematic
Figure 002A (SHEET 2)



EFF :

101-199, 901-999,  33-34-00

Page 11
Feb 01/07
 
IAC 
The 28VDC busbar 602PP supplies the aft loading-area light 12LU through the
circuit breaker 3LU and the toggle switch 9LU.



EFF :

901-999,  33-34-00

Page 12
Feb 01/07
 
IAC 
FWD - AFT CARGO COMPARTMENT LIGHTING - ADJUSTMENT/TEST
______________________________________________________

TASK 33-34-00-710-001

Operational Test of the FWD and AFT Cargo Compartment Lighting

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

To make sure that the FWD, AFT and bulk cargo-compartment lighting operates
correctly.

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific access platform 2.0 m (6 ft. 7 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump
52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump
R 52-30-00-860-006 Open the Bulk Cargo-Compartment Door
R 52-30-00-860-008 Close the Bulk Cargo-Compartment Door

3. __________
Job Set-up

Subtask 33-34-00-861-050

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).



EFF :

ALL  33-34-00

Page 501
Feb 01/07
 
IAC 
**ON A/C 001-012, 014-099,

Subtask 33-34-00-865-050

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU CARGO COMPT LIGHT - FWD 1LU B04
2000VU CARGO COMPT LIGHT - AFT 2LU B05
2000VU CARGO COMPT LIGHT - LDG AREA 3LU B06

R **ON A/C 101-199, 901-999,

Subtask 33-34-00-865-050-A

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LIGHT - CARGO COMPT - FWD 1LU J06
2000VU LIGHT - CARGO COMPT - AFT 2LU J07
2000VU LIGHT - LDG AREA 3LU J08

R **ON A/C 001-012, 014-099, 901-999,

Subtask 33-34-00-010-050

C. Get Access

(1) For the FWD Cargo Compartment:

(a) Open the FWD cargo-compartment door 825 (Ref. TASK 52-30-00-860-
001).

(b) Put the access platform in position at the FWD cargo-compartment


door 825.

(2) For the AFT Cargo Compartment and the Bulk Cargo Compartment:

(a) Open the AFT cargo-compartment door 826 (Ref. TASK 52-30-00-860-
001).



EFF :

ALL  33-34-00

Page 502
Feb 01/07
 
IAC 
(b) Put the access platform in position at the AFT cargo-compartment
door 826.

R **ON A/C 101-199,

R Subtask 33-34-00-010-050-A

R C. Get Access

R (1) For the FWD Cargo Compartment:

R (a) Open the FWD cargo-compartment door 825 (Ref. TASK 52-30-00-860-
R 001).

R (b) Put the access platform in position at the FWD cargo-compartment


R door 825.

R (2) For the AFT Cargo Compartment:

R (a) Open the AFT cargo-compartment door 826 (Ref. TASK 52-30-00-860-
R 001).

R (b) Put the access platform in position at the AFT cargo-compartment


R door 826.

R (3) For the Bulk Cargo Compartment:

R (a) Open the bulk cargo-compartment door 827 (Ref. TASK 52-30-00-860-
R 006).

R (b) Put the access platform in position at the bulk cargo-compartment


R door 827.



EFF :

ALL  33-34-00

Page 503
Feb 01/07
 
IAC 
R **ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

Subtask 33-34-00-710-050

A. Test of the Lighting in the FWD Cargo-Compartment

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. In the FWD cargo compartment: In the FWD cargo compartment:


- set the switch 6LU to the ON - the ceiling lights 13LU and 14LU come
position. on.

- set the switch 6LU to the OFF - the ceiling lights 13LU and 14LU go
position. off.

- set the switch 7LU to the ON - the forward loading-area light 11LU
position. comes on.

- set the switch 7LU to the OFF - the forward loading-area light 11LU
position. goes off.



EFF :

ALL  33-34-00

Page 504
Feb 01/07
 
IAC 
R **ON A/C 101-199,

R Subtask 33-34-00-710-050-B

R A. Test of the Lighting in the FWD Cargo-Compartment

R (1) Do this test.

R -------------------------------------------------------------------------------
R ACTION RESULT
R -------------------------------------------------------------------------------

R 1. In the FWD cargo compartment: In the FWD cargo compartment:


R - set the switch 6LU to the ON - the ceiling lights 13LU, 14LU, 20LU
R position. and 21LU come on.

R - set the switch 6LU to the OFF - the ceiling lights 13LU, 14LU, 20LU
R position. and 21LU go off.

R - set the switch 7LU to the ON - the forward loading-area light 11LU
R position. comes on.

R - set the switch 7LU to the OFF - the forward loading-area light 11LU
R position. goes off.

R **ON A/C 901-999,

Subtask 33-34-00-710-050-A

A. Test of the Lighting in the FWD Cargo-Compartment

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. In the FWD cargo compartment: In the FWD cargo compartment:


- set the switch 6LU to the ON - the ceiling light 13LU comes on.
position.

- set the switch 6LU to the OFF - the ceiling light 13LU goes off.
position.


R

EFF :

101-199, 901-999,  33-34-00

Page 505
Feb 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- set the switch 7LU to the ON - the forward loading-area light 11LU
position. comes on.

- set the switch 7LU to the OFF - the forward loading-area light 11LU
position. goes off.

R **ON A/C 001-012, 014-099, 901-999,

Subtask 33-34-00-710-051

B. Test of the Lighting in the AFT and the Bulk Cargo-Compartment

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. In the AFT cargo-compartment: In the AFT cargo-compartment:


- set the switch 8LU to the ON - the ceiling lights 15LU and 16LU come
position. on.

In the bulk cargo-compartment:


- the ceiling light 17LU comes on.

- set the switch 8LU to the OFF - the ceiling light 17LU goes off.
position.

In the AFT cargo-compartment:


- the ceiling lights 15LU and 16LU go
off.

- set the switch 9LU to the ON - the AFT loading-area light 12LU comes
position. on.

- set the switch 9LU to the OFF - the AFT loading-area light 12LU goes
position. off.



EFF :

001-012, 014-099, 901-999,  33-34-00

Page 506
Feb 01/07
 
IAC 
R **ON A/C 101-199,

R Subtask 33-34-00-710-051-A

R B. Test of the Lighting in the AFT and the Bulk Cargo-Compartment

R (1) Do this test.

R -------------------------------------------------------------------------------
R ACTION RESULT
R -------------------------------------------------------------------------------

R 1. In the AFT cargo-compartment: In the AFT cargo-compartment:


R - set the switch 8LU to the ON - the ceiling lights 15LU, 16LU and
R position. 22LU come on.

R - set the switch 8LU to the OFF - the ceiling lights 15LU, 16LU and
R position. 22LU go off.

R - set the switch 9LU to the ON - the AFT loading-area light 12LU comes
R position. on.

R - set the switch 9LU to the OFF - the AFT loading-area light 12LU goes
R position. off.

R 2. In the bulk cargo-compartment: In the bulk cargo-compartment:


R - set the switch 18LU to the ON - the ceiling light 17LU comes on.
R position.

R - set the switch 18LU to the OFF - the ceiling light 17LU goes off.
R position.



EFF :

101-199,  33-34-00

Page 507
Feb 01/07
 
IAC 
R **ON A/C ALL

5. Close-up
________

R **ON A/C 001-012, 014-099, 901-999,

Subtask 33-34-00-410-050

A. Close Access

(1) Remove the access platform(s).

(2) For the FWD Cargo Compartment:

(a) Close the FWD cargo-compartment door 825 (Ref. TASK 52-30-00-860-
002).

(3) For the AFT Cargo Compartment and the Bulk Cargo Compartment:

(a) Close the AFT cargo-compartment door 826 (Ref. TASK 52-30-00-860-
002).

R **ON A/C 101-199,

R Subtask 33-34-00-410-050-A

R A. Close Access

R (1) Remove the access platform(s).

R (2) For the FWD Cargo Compartment:

R (a) Close the FWD cargo-compartment door 825 (Ref. TASK 52-30-00-860-
R 002).

R (3) For the AFT Cargo Compartment:

R (a) Close the AFT cargo-compartment door 826 (Ref. TASK 52-30-00-860-
R 002).

R (4) For the Bulk Cargo Compartment:

R (a) Close the bulk cargo-compartment door 827 (Ref. TASK 52-30-00-
R 860-008).



EFF :

ALL  33-34-00

Page 508
Feb 01/07
 
IAC 
R **ON A/C ALL

Subtask 33-34-00-862-050

B. De-energize the aircraft electrical circuit (Ref. TASK 24-41-00-862-002).



EFF :

ALL  33-34-00

Page 509
Feb 01/07
 
IAC 
BALLAST UNIT WITH LAMPHOLDER (13LU,14LU,15LU,16LU,17LU) - SERVICING
___________________________________________________________________

TASK 33-34-11-600-001

Servicing of the Ballast Units with Lampholders

WARNING : ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE
_______
ENVIRONMENT.

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

NOTE : The procedure is the same for all the ballast units with lampholder in
____
the FWD and AFT cargo compartment.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific access platform 2.0 m (6 ft. 7 in.)



EFF :

ALL  33-34-11

Page 301
May 01/06
R  
IAC 
B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-34-00-710-001 Operational Test of the FWD and AFT Cargo Compartment


Lighting
52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump
52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump

**ON A/C 001-012, 014-099,

33-34-11-991-002 Fig. 301

**ON A/C 101-199,

R 33-34-11-991-002-B Fig. 301A

R **ON A/C 901-999,

R 33-34-11-991-002-A Fig. 301B

**ON A/C ALL

3. __________
Job Set-up

**ON A/C 001-012, 014-099,

Subtask 33-34-11-865-053

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU CARGO COMPT LIGHT - FWD 1LU B04
2000VU CARGO COMPT LIGHT - AFT 2LU B05



EFF :

ALL  33-34-11

Page 302
Feb 01/07
 
IAC 
R **ON A/C 101-199, 901-999,

Subtask 33-34-11-865-053-A

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LIGHT - CARGO COMPT - FWD 1LU J06
2000VU LIGHT - CARGO COMPT - AFT 2LU J07

**ON A/C ALL

Subtask 33-34-11-010-052

B. Get Access

(1) Put an access platform in position at the FWD and/or AFT


cargo-compartment door 825, 826.

(2) Open the FWD and/or AFT cargo-compartment door and install the
actuator safety-locks (Ref. TASK 52-30-00-860-001).

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 301/TASK 33-34-11-991-002)

**ON A/C 101-199,

R (Ref. Fig. 301A/TASK 33-34-11-991-002-B)

R **ON A/C 901-999,

R (Ref. Fig. 301B/TASK 33-34-11-991-002-A)



EFF :

ALL  33-34-11

Page 303
Feb 01/07
 
IAC 
Ballast Unit with Lampholder
Figure 301/TASK 33-34-11-991-002


R

EFF :

001-012, 014-099,  33-34-11

Page 304
May 01/06
 
IAC 
R Ballast Unit with Lampholder
R Figure 301A/TASK 33-34-11-991-002-B



EFF :

101-199,  33-34-11

Page 305
Feb 01/07
 
IAC 
Ballast Unit with Lampholder
R Figure 301B/TASK 33-34-11-991-002-A


R

EFF :

901-999,  33-34-11

Page 306
Feb 01/07
 
IAC 
**ON A/C ALL

Subtask 33-34-11-020-053

A. Removal of the Fluorescent Lamp

(1) Release the quick-release fasteners (1) around the glass cover (2).

(2) Remove the glass cover (2) from the lamp housing (6).

(3) Push the buttons (4) at each end of the lampholder (5).

(4) Remove and discard the fluorescent lamp (3).

Subtask 33-34-11-420-051

B. Installation of the Fluorescent Lamp

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Replace the fluorescent lamp (3).

(4) Install the glass cover (2) to the lamp housing (6).

Subtask 33-34-11-865-054

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LU and 2LU.

5. Close-up
________

Subtask 33-34-11-710-051

A. Do an operational test of the FWD and AFT cargo compartment lighting


(Ref. TASK 33-34-00-710-001).



EFF :

ALL  33-34-11

Page 307
Feb 01/07
R  
IAC 
Subtask 33-34-11-410-051

B. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the actuator safety-locks and close the FWD and/or AFT
cargo-compartment door (Ref. TASK 52-30-00-860-002).

(3) Remove the access platform(s).



EFF :

ALL  33-34-11

Page 308
Feb 01/07
 
IAC 
BALLAST UNIT WITH LAMPHOLDER (13LU,14LU,15LU,16LU,17LU) - REMOVAL/INSTALLATION
______________________________________________________________________________

TASK 33-34-11-000-001

Removal of the Ballast Unit and Lampholder

WARNING : ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE
_______
ENVIRONMENT.

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

NOTE : The procedure is the same for all the fluorescent lighting in the fwd
____
and aft cargo compartment.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific access platform 2.0 m (6 ft. 7 in.)



EFF :

ALL  33-34-11

Page 401
May 01/06
R  
IAC 
B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-099,

33-34-11-991-001 Fig. 401

**ON A/C 101-199,

R 33-34-11-991-001-B Fig. 401A

R **ON A/C 901-999,

R 33-34-11-991-001-A Fig. 401B


FOR FIN 15LU, 16LU, 17LU
52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump
R FOR FIN 15LU, 16LU, 17LU, 22LU
R 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
R Yellow Electric Pump

**ON A/C ALL

3. __________
Job Set-up

**ON A/C 001-012, 014-099,

Subtask 33-34-11-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU CARGO COMPT LIGHT - FWD 1LU B04
2000VU CARGO COMPT LIGHT - AFT 2LU B05



EFF :

ALL  33-34-11

Page 402
Feb 01/07
 
IAC 
R **ON A/C 101-199, 901-999,

Subtask 33-34-11-865-050-A

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LIGHT - CARGO COMPT - FWD 1LU J06
2000VU LIGHT - CARGO COMPT - AFT 2LU J07

R **ON A/C 001-012, 014-099,

R Subtask 33-34-11-010-050

R B. Get Access

R (1) Put the access platform in position:


R FOR 13LU, 14LU
R at the FWD cargo-compartment door 825,
R FOR 15LU, 16LU, 17LU
R at the AFT cargo-compartment door 826.

R (2) Open the related cargo-compartment door and install the actuator
R safety-locks (Ref. TASK 52-30-00-860-001).

R (3) Remove the ceiling panel in the FWD cargo-compartment to get access
R to the electrical connector (5):
R FOR 13LU
R remove 131AC,
R FOR 14LU
R remove 131BC.

R (4) Remove the ceiling panel in the AFT cargo-compartment to get access
R to the electrical connector (5):
R FOR 15LU
R remove 151BC,
R FOR 16LU
R remove 151CC,
R FOR 17LU
R remove 161AC.



EFF :

ALL  33-34-11

Page 403
Feb 01/07
 
IAC 
R **ON A/C 101-199,

R Subtask 33-34-11-010-050-B

R B. Get Access

R (1) Put the access platform in position:


R FOR 13LU, 14LU, 20LU, 21LU
R at the FWD cargo-compartment door 825,
R FOR 15LU, 16LU, 17LU, 22LU
R at the AFT cargo-compartment door 826.

R (2) Open the related cargo-compartment door and install the actuator
R safety-locks (Ref. TASK 52-30-00-860-001).

R (3) Remove the ceiling panel in the FWD cargo-compartment to get access
R to the electrical connector (5):
R FOR 13LU
R remove 131AC,
R FOR 14LU
R remove 131BC,
R FOR 20LU
R remove 131CC,
R FOR 21LU
R remove 131DC.

R (4) Remove the ceiling panel in the AFT cargo-compartment to get access
R to the electrical connector (5):
R FOR 15LU
R remove 151BC,
R FOR 16LU
R remove 151CC,
R FOR 17LU
R remove 161AC,
R FOR 22LU
R remove 151AC.


R

EFF :

101-199,  33-34-11

Page 404
Feb 01/07
 
IAC 
R **ON A/C 901-999,

Subtask 33-34-11-010-050-A

B. Get Access

(1) Put the access platform in position:


FOR 13LU
at the FWD cargo-compartment door 825,
FOR 15LU, 16LU, 17LU
at the AFT cargo-compartment door 826.

(2) Open the related cargo-compartment door and install the actuator
safety-locks (Ref. TASK 52-30-00-860-001).

(3) Remove the ceiling panel in the FWD cargo-compartment to get access
to the electrical connector (5):
FOR 13LU
remove 131AC.

(4) Remove the ceiling panel in the AFT cargo-compartment to get access
to the electrical connector (5):
FOR 15LU
remove 151BC,
FOR 16LU
remove 151CC,
FOR 17LU
remove 161AC.

**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-34-11-991-001)

**ON A/C 101-199,

R (Ref. Fig. 401A/TASK 33-34-11-991-001-B)


R

EFF :

ALL  33-34-11

Page 405
Feb 01/07
 
IAC 
Ballast Unit with Lampholder
Figure 401/TASK 33-34-11-991-001


R

EFF :

001-012, 014-099,  33-34-11

Page 406
Feb 01/07
 
IAC 
R Ballast Unit with Lampholder
R Figure 401A/TASK 33-34-11-991-001-B


R

EFF :

101-199,  33-34-11

Page 407
Feb 01/07
 
IAC 
R **ON A/C 901-999,

R (Ref. Fig. 401B/TASK 33-34-11-991-001-A)

**ON A/C ALL

Subtask 33-34-11-020-051

A. Removal of the Ballast Unit and the Lampholder

(1) Disconnect the electrical connector (5).

(2) Put blanking caps on the disconnected electrical connectors.

(3) Release the quick-release fasteners (1).

(4) Remove the glass cover (2) from the lamp housing (10).

(5) Push the buttons (4) at each end of the lampholder (6) and remove the
fluorescent lamp (3).

(6) Remove the screws (11), the washers (12) and the nuts (13).

(7) Remove the cover plate (8) and the gasket (9) from the lamp housing
(10).

(8) Remove the screws (14).

(9) Remove the ballast unit and lampholder (6) and the reflector (7) from
the lamp housing (10).



EFF :

ALL  33-34-11

Page 408
Feb 01/07
 
IAC 
Ballast Unit with Lampholder
R Figure 401B/TASK 33-34-11-991-001-A


R

EFF :

901-999,  33-34-11

Page 409
Feb 01/07
 
IAC 
TASK 33-34-11-400-001

Installation of the Ballast Unit and Lampholder

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-34-00-710-001 Operational Test of the FWD and AFT Cargo Compartment


Lighting
52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump

**ON A/C 001-012, 014-099,

33-34-11-991-001 Fig. 401

**ON A/C 101-199,

R 33-34-11-991-001-B Fig. 401A

R **ON A/C 901-999,

R 33-34-11-991-001-A Fig. 401B



EFF :

ALL  33-34-11

Page 410
Feb 01/07
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

**ON A/C 001-012, 014-099,

Subtask 33-34-11-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU CARGO COMPT LIGHT - FWD 1LU B04
2000VU CARGO COMPT LIGHT - AFT 2LU B05

R **ON A/C 101-199, 901-999,

Subtask 33-34-11-865-051-A

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2000VU LIGHT - CARGO COMPT - FWD 1LU J06
2000VU LIGHT - CARGO COMPT - AFT 2LU J07

**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-34-11-991-001)

**ON A/C 101-199,

R (Ref. Fig. 401A/TASK 33-34-11-991-001-B)



EFF :

ALL  33-34-11

Page 411
Feb 01/07
 
IAC 
R **ON A/C 901-999,

R (Ref. Fig. 401B/TASK 33-34-11-991-001-A)

**ON A/C ALL

Subtask 33-34-11-420-050

A. Installation of the Ballast Unit and the Lampholder

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Install the reflector (7) and the ballast unit and lampholder (6) to
the lamp housing (10) with the screws (14).

(4) Put the electrical connector (5) through the hole in the lamp housing
(10).

(5) Install the gasket (9) and the cover plate (8) with the screws (11),
the washers (12) and the nuts (13).

(6) Install the fluorescent lamp (3).

(7) Install the glass cover (2) with the quick-release fasteners (1).

(8) Remove the blanking caps from the electrical connectors.

(9) Make sure that the electrical connectors are clean and in the correct
condition.

(10) Connect the electrical connector (5).

Subtask 33-34-11-865-052

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LU and 2LU.

Subtask 33-34-11-710-050

C. Do an operational test of the FWD and AFT cargo compartment lighting


(Ref. TASK 33-34-00-710-001).



EFF :

ALL  33-34-11

Page 412
Feb 01/07
 
IAC 
5. Close-up
________

Subtask 33-34-11-410-050

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the related ceiling panel(s) in the FWD and/or AFT cargo
compartment.

(3) Remove the actuator safety-locks and close the FWD and/or AFT
cargo-compartment door(s) (Ref. TASK 52-30-00-860-002).

(4) Remove the access platform(s).



EFF :

ALL  33-34-11

Page 413
Feb 01/07
 
IAC 
LIGHT - LOADING AREA (11LU,12LU) - REMOVAL/INSTALLATION
_______________________________________________________

TASK 33-34-12-000-001

Removal of the Loading-Area Light (11LU, 12LU)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific access platform 2.5 m (8 ft. 2 in.)
M81969-14-02 1 INSERTION/REMOVAL TOOL

B. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

R 5 gasket 33-34-12 03 -020

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-42-00-861-001 Energize the Ground Service Network from the External


Power
52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump

**ON A/C 001-012, 014-099,

33-34-12-991-001 Fig. 401



EFF :

ALL  33-34-12

Page 401
Feb 01/07
 
IAC 
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R **ON A/C 101-199, 901-999,

33-34-12-991-001-A Fig. 401A

**ON A/C 001-012, 014-099,

33-34-12-991-002 Fig. 402


FOR FIN 11LU
25-54-12-000-002 Removal of the Ceiling Panels in the FWD Cargo
Compartment
FOR FIN 12LU
25-55-11-000-002 Removal of the Ceiling Panels in the AFT Cargo
Compartment - FR47/FR59

**ON A/C ALL

3. __________
Job Set-up

Subtask 33-34-12-861-050

A. Energize the ground service network


(Ref. TASK 24-42-00-861-001).

Subtask 33-34-12-010-050

B. Get Access

(1) Open the FWD and/or AFT cargo-compartment door(s) (Ref. TASK 52-30-
00-860-001).

(2) Put an access platform in position at the FWD and/or AFT


cargo-compartment door.

(3) Set the FWD Loading-Area Light switch 7LU and/or the AFT Loading-Area
Light switch 9LU to the ON position.



EFF :

ALL  33-34-12

Page 402
Feb 01/07
 
IAC 
(4) Remove the applicable cargo-compartment ceiling panel:
FOR 11LU
131AC (Ref. TASK 25-54-12-000-002).
FOR 12LU
151CC (Ref. TASK 25-55-11-000-002).

(5) Get access to the applicable 2000VU series panel.

Subtask 33-34-12-865-050

C. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R FOR 11LU, 12LU

R **ON A/C 001-012, 014-099,

R 2000VU CARGO COMPT LIGHT LDG AREA 3LU B06

**ON A/C 101-199, 901-999,

R 2000VU LIGHT-LDG-AREA 3LU J08

**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

Subtask 33-34-12-020-050

R A. Removal of the Loading-Area Light (11LU, 12LU)


(Ref. Fig. 401/TASK 33-34-12-991-001)

(1) Removal of the Loading-Area Light-Housing

(a) Remove the screws (7) from the access panel (6).

(b) Remove the access panel (6).

(c) Remove the screws (9), the washers (8) and the nuts (12).



EFF :

ALL  33-34-12

Page 403
May 01/07
 
IAC 
Removal/installation of the Loading-Area Light
Figure 401/TASK 33-34-12-991-001


R

EFF :

001-012, 014-099,  33-34-12

Page 404
May 01/06
 
IAC 
(d) Remove the bracket assembly (5) and the gasket (4).

(e) Use the INSERTION/REMOVAL TOOL to disconnect the electrical


connectors (11).

(f) Remove the screws (2), the washers (1) and the nuts (13) from the
bracket (14).

(g) Remove the loading-area light-housing (10).

(h) Remove the flange assembly (3).

(2) Removal of the Bulb of the Loading-Area Light


(Ref. Fig. 402/TASK 33-34-12-991-002)

R (a) Loosen the screw (2) of the clamping ring (1).

R (b) Remove the clamping ring (1) and the lens (3).

R (c) Remove the bulb (4) from the loading-area light housing (5).

**ON A/C 101-199, 901-999,

Subtask 33-34-12-020-050-A

A. Removal of the Loading-Area Light (11LU, 12LU)


(Ref. Fig. 401A/TASK 33-34-12-991-001-A)

(1) Hold the housing (1) and remove the six screws (4) that attach the
frame (3) on the housing (1).

(2) Carefully remove the frame (3) with the loosely assembled lens (2)
from the housing (1).

(3) Remove and discard the gasket (5).



EFF :

ALL  33-34-12

Page 405
May 01/07
 
IAC 
Removal/installation of the Loading-Area Light
Figure 401A/TASK 33-34-12-991-001-A


R

EFF :

101-199, 901-999,  33-34-12

Page 406
Feb 01/07
 
IAC 
R Removal/Installation of the Bulb of the Loading-Area Light
Figure 402/TASK 33-34-12-991-002



EFF :

001-012, 014-099,  33-34-12

Page 407
May 01/07
 
IAC 
R **ON A/C ALL

TASK 33-34-12-400-001

Installation of the Loading-Area Light (11LU, 12LU)

R WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL MATERIALS


_______
R ONLY WITH A GOOD SUPPLY OF AIR.
R OBEY THE MANUFACTURERS INSTRUCTIONS.
R PUT ON PROTECTIVE CLOTHING.
R DO NOT GET THEM IN YOUR MOUTH.
R DO NOT SMOKE.
R DO NOT BREATHE THE GAS.
R THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT.
R GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific access platform 2.5 m (8 ft. 2 in.)


M81969-14-02 1 INSERTION/REMOVAL TOOL

R B. Consumable Materials

R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------

R Material No. 08-002 USA MIL-R-46082 TYPE I


R GENERAL PURPOSE DIMETHACRYLATE GREEN (Ref. 20-31-00)



EFF :

ALL  33-34-12

Page 408
May 01/06
 
IAC 
C. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

R 5 gasket 33-34-12 03 -020

D. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-42-00-861-001 Energize the Ground Service Network from the External


Power
24-42-00-862-001 De-energize the Ground Service Network Supplied from
the External Power
52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump
52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump

**ON A/C 001-012, 014-099,

33-34-12-991-001 Fig. 401

R **ON A/C 101-199, 901-999,

33-34-12-991-001-A Fig. 401A

**ON A/C 001-012, 014-099,

33-34-12-991-002 Fig. 402


FOR FIN 11LU
25-54-12-000-002 Removal of the Ceiling Panels in the FWD Cargo
Compartment
25-54-12-400-002 Installation of the Ceiling Panels in the FWD Cargo
Compartment
FOR FIN 12LU
25-55-11-000-002 Removal of the Ceiling Panels in the AFT Cargo
Compartment - FR47/FR59
25-55-11-400-002 Installation of the Ceiling Panels in the AFT Cargo
Compartment -FR47/FR59



EFF :

ALL  33-34-12

Page 409
Feb 01/07
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-34-12-860-050

A. Aircraft Maintenance Configuration

(1) Make sure that the ground service network is energized


(Ref. TASK 24-42-00-861-001).

(2) Make sure that the FWD and/or AFT cargo-compartment door(s)
(Ref. TASK 52-30-00-860-001) is (are) open.

(3) Make sure that the access platform are in position at the FWD and/or
AFT cargo-compartment door.

(4) Make sure that the FWD Loading-Area Light switch 7LU and/or the AFT
Loading-Area Light switch 9LU is in the ON position.

(5) Make sure that the applicable cargo-compartment ceiling panel is


removed:
FOR 11LU
131AC (Ref. TASK 25-54-12-000-002).
FOR 12LU
151CC (Ref. TASK 25-55-11-000-002).

(6) Make sure that you have access to the applicable 2000VU series
panel(s).



EFF :

ALL  33-34-12

Page 410
Aug 01/06
R  
IAC 
Subtask 33-34-12-865-051

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R FOR 11LU, 12LU

R **ON A/C 001-012, 014-099,

R 2000VU CARGO COMPT LIGHT LDG AREA 3LU B06

**ON A/C 101-199, 901-999,

R 2000VU LIGHT-LDG-AREA 3LU J08

**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

Subtask 33-34-12-420-050

A. Installation of the Loading-Area Light

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Installation of the Bulb of the Loading-Area Light


(Ref. Fig. 402/TASK 33-34-12-991-002)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF
THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.

R (a) Install the bulb (4) in the loading-area light housing (5).



EFF :

ALL  33-34-12

Page 411
May 01/07
 
IAC 
R (b) Install the lens (3) and the clamping ring (1).

R (c) Tighten the screw (2) of the clamping ring (1).

(4) Installation of the Loading-Area Light Housing


(Ref. Fig. 401/TASK 33-34-12-991-001)

(a) Put the loading-area light-housing (10) in position on the


bracket (3).

R (b) Put the gasket (4) in position on the bracket assembly (5) and
R install the screws (9), the washers (8) and the nuts (12) on the
bracket (3).

(c) Do not fully tighten the screws (9) at this stage.

NOTE : The loading-area light-housing (10) is now clamped between


____
the bracket assembly (5) and the bracket (3).

(d) Make sure that the electrical connectors are clean and in the
correct condition.

(e) Use the INSERTION/REMOVAL TOOL (M81969-14-02) to connect the


electrical connectors (11).

(f) Install the loading-area light-housing (10) with the screws (2),
the washers (1) and the nuts (13) on the bracket (14) on the
aircraft structure.

(g) Install the access panel (6) with the screws (7) on the bracket
assembly (5).

R (h) Now fully tighten the screws (9).



EFF :

001-012, 014-099,  33-34-12

Page 412
May 01/07
 
IAC 
R **ON A/C 101-199, 901-999,

Subtask 33-34-12-420-050-A

A. Installation of the Loading-Area Light (11LU, 12LU)


(Ref. Fig. 401A/TASK 33-34-12-991-001-A)

R (1) Put the new gasket (5) around the lens (2).

(2) Loosely assemble the lens (2) in the housing (1).

WARNING : OBEY THE MANUFACTURERS INSTRUCTIONS WHEN YOU USE


_______
THIS/THESE MATERIAL/S.
USE PROTECTIVE CLOTHING, RUBBER GLOVES, GOGGLES AND A MASK.

(3) Apply BONDING AND ADHESIVE COMPOUNDS (Material No. 08-002) to the
threads of screws (4).

(4) Carefully hold the frame (3) with the lens (2) and align the holes of
the housing (1) with those in the frame (3).

(5) Attach the housing (1) to the frame (3) with the six screws (4).

**ON A/C ALL

Subtask 33-34-12-865-052

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
FOR 11LU, 12LU
3LU



EFF :

ALL  33-34-12

Page 413
Feb 01/07
 
IAC 
Subtask 33-34-12-710-050

C. Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. At the FWD cargo-compartment door At the forward loading area:


operation-panel:

- set the switch 7LU to the ON - the forward loading-area light 11LU
position. comes on.

- set the switch 7LU to the OFF - the forward loading-area light 11LU
position. goes off.

2. At the AFT cargo-compartment door At the aft loading area:


operation-panel:

- set the switch 9LU in the ON - the aft loading area light 12LU comes
position. on.

- set the switch 9LU to the OFF - the loading area light 12LU goes off.
position.

5. Close-up
________

Subtask 33-34-12-410-050

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the applicable cargo-compartment ceiling panel:


- FOR 11LU
131AC (Ref. TASK 25-54-12-400-002).
- FOR 12LU
151CC (Ref. TASK 25-55-11-400-002).

(3) Set the FWD Loading-Area Light switch 7LU and/or the AFT Loading-Area
Light switch 9LU to the OFF position.

(4) Remove the access platform(s).



EFF :

ALL  33-34-12

Page 414
Aug 01/06
R  
IAC 
(5) Close the FWD and/or AFT cargo-compartment door(s) (Ref. TASK 52-30-
00-860-002).

Subtask 33-34-12-862-050

B. De-energize the ground service network


(Ref. TASK 24-42-00-862-001).


R

EFF :

ALL  33-34-12

Page 415
Aug 01/06
 
IAC 
AVIONICS COMPARTMENT LIGHTING - DESCRIPTION AND OPERATION
_________________________________________________________

1. _______
General
The avionics compartment lighting system consists of six lights, five 28 VDC
outlets and three 115 VAC outlets.

2. __________________
Component Location

**ON A/C 001-010,

(Ref. Fig. 001)

R **ON A/C 011-012, 014-099, 101-199, 901-999,

(Ref. Fig. 001A)

**ON A/C ALL

_______________________________________________________________________________
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
6LS LT-DOME, AVIONICS COMPT FWD R 122 811 33-35-11
7LS LT-DOME, AVIONICS COMPT FWD L 121 811 33-35-11
8LS LT-DOME, AVIONICS COMPT LAT R 126 822 33-35-11
9LS LT-DOME, AVIONICS COMPT AFT L 127 824 33-35-11
10LS LT-DOME, AVIONICS COMPT AFT R 128 824 33-35-11
13LS OUTLET-AVIONICS COMPT, AFT L 127 824
14LS OUTLET-AVIONICS COMPT, AFT R 128 824
15LS OUTLET-AVIONICS COMPT, FWD L 121 811
16LS OUTLET-AVIONICS COMPT, LATERAL R 126 822
17LS OUTLET-AVIONICS COMPT, AFT R 128 824
18LS OUTLET-AVIONICS COMPT, LATERAL R 126 822
19LS OUTLET-AVIONICS COMPT, FWD R 122 811
20LS OUTLET-AVIONICS COMPT, LATERAL L 125 812
22LS LT-DOME, AVIONICS COMPT LAT L 125 812 33-35-11
23LS P/B SW-AVIONICS COMPT LT 50VU 212
24LS RELAY-PWR SPLY, AVIONICS COMPT 103VU 126
AFT L DOME LIGHT
25LS RELAY-PWR SPLY, AVIONICS COMPT 103VU 126
FWD R DOME LIGHT



EFF :

ALL  33-35-00

Page 1
Feb 01/07
 
IAC 
Avionics Compartment Lighting - Component Location
Figure 001



EFF :

001-010,  33-35-00

Page 2
Feb 01/96
 
IAC 
Avionics Compartment Lighting - Component Location
Figure 001A


R

EFF :

011-012, 014-099, 101-199, 901-999,  33-35-00

Page 3
Feb 01/07
 
IAC 
3. System
__________________
Description
(Ref. Fig. 002)
The avionics compartment lighting system consists of a number of lights and
maintenance outlets. The busbar 601PP supplies the five maintenance outlets
with 28 VDC through circuit breaker 11LS. The busbar 216XP supplies the
three maintenance outlets with 115 VAC through circuit breaker 12LS. The
outlets are located in the forward and aft parts of the avionics
compartement.
Six dome lights provide the illumination of the avionics compartment.
The busbar 601PP supplies the lights with 28 VDC through circuit breaker 1LS
and relays 24LS and 25LS. The relay 24LS controls the power supply to the
lateral L, aft L and R dome lights. The relay 25LS controls the power supply
to the lateral R, forward L and R dome lights. The door proximity switches
transmit the ground signal to relays 24LS and 25LS.

4. Operation/Control
________________________________
and Indicating
(Ref. Fig. 003)
If the conditions below are obeyed:
- busbar energized,
- circuit breaker 1LS closed,
- all avionics compartment doors closed,
- the two relays 24LS and 25LS energized,
all the lights are off.

A. Auto Mode

(1) When the service door in zone 125 or zone 128 is open, the associated
proximity switch removes the ground for relay 24LS. Relay 24LS
de-energizes and the L lateral, L and R aft dome lights come on.

(2) When the service door in zone 120 or zone 126 is open, the associated
proximity switch removes the ground for relay 25LS. Relay 25LS
de-energizes and the R lateral, L and R forward dome lights come on.

B. Manual Mode
When the pushbutton switch 23LS is pressed, the two relays 24LS and 25LS
de-energize and the avionics compartment lights come on. The integral
light in the pushbutton switch comes on.



EFF :

ALL  33-35-00

Page 4
Feb 01/96
 
IAC 
Avionics Compartment Lighting - Electrical Outlets
Figure 002



EFF :

ALL  33-35-00

Page 5
Feb 01/96
 
IAC 
Avionics Compartment Lighting - Schematic
Figure 003



EFF :

ALL  33-35-00

Page 6
Feb 01/96
 
IAC 
AVIONICS COMPARTMENT LIGHTING - ADJUSTMENT/TEST
_______________________________________________

TASK 33-35-00-720-001

Functional Test of the Avionics-Compartment Lighting

1. __________________
Reason for the Job

To make sure that the lighting of the avionics compartments operates


correctly

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific access platform 2.06 m (6 ft. 9 in.)


No specific access platform 2.50 m (8 ft. 2 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
R 52-41-00-410-002 Close the Avionics Compartment Doors after Access

3. __________
Job Set-up

Subtask 33-35-00-861-051

A. Energize the aircraft electrical circuits


(Ref. TASK 24-41-00-861-002).



EFF :

ALL  33-35-00

Page 501
May 01/02
 
IAC 
Subtask 33-35-00-865-050

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/AVNCS COMPT/DOME 1LS Z07

Subtask 33-35-00-010-050

C. Get access to the Avionics Compartment

(1) Put the access platform at door 811.

(2) Put the access platform at door 812.

(3) Put the access platform at door 822.

(4) Put the access platform at door 824.

(5) Open the forward door 811 of the avionics compartment.

(6) Do not open the lateral left door 812 of the avionics compartment.

(7) Do not open the lateral right door 822 of the avionics compartment.

(8) Do not open the aft door 824 of the avionics compartment.



EFF :

ALL  33-35-00

Page 502
Aug 01/06
 
IAC 
4. Procedure
_________

Subtask 33-35-00-720-050

A. Functional Test of the Avionics Compartment Lighting

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the panel 50VU: On the panel 50VU:


- push the AVIONICS/COMPT LT - the ON legend of this pushbutton
pushbutton switch. switch comes on.
Look through the door 811:
- make sure that the dome lights (7LS,
6LS, 8LS, 22LS, 10LS, 9LS) come on in
the avionics compartments.

2. On the panel 50VU: Look through the door 811:


- push then release the - make sure that the two forward
AVIONICS/COMPT/LT pushbutton dome-lights (7LS, 6LS) and the
switch. lateral right dome-light (8LS) are on
in the avionics compartment,
- make sure that all the other dome
lights (22LS, 10LS, 9LS) go off in
the avionics compartment.
On the panel 50VU:
- the ON legend of the
AVIONICS/COMPT/LT pushbutton switch
goes off.

3. Open the aft door 824 of the Make sure that:


avionics compartment. - the two aft dome lights (10LS, 9LS)
come on in the avionics compartment,
- the lateral left dome light (22LS)
comes on in the avionics compartment.

4. Close the aft door 824 of the Look through the door 811.
avionics compartment (Ref. TASK Make sure that:
52-41-00-410-002). - the two aft dome-lights (10LS, 9LS)
go off in the avionics compartment,
- the lateral left dome-light (22LS)
goes off in the avionics compartment.

5. Open the lateral left door 812 of Look through the door 812:
the avionics compartment. - You must get the same results as in
paragraph 3.



EFF :

ALL  33-35-00

Page 503
May 01/06
R  
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
6. Close the lateral left door 812 Look through the door 812:
of the avionics compartment. - You must get the same results as in
paragraph 4.

7. Close the forward door 811 of the Make sure that:


avionics compartment, - the two forward dome-lights (7LS,
and open again the lateral left 6LS) go off in the avionics
door 812 of the avionics compartment,
compartment. - the lateral right light (8LS) goes
off in the avionics compartment is
off.

8. Open the right lateral door 822 Make sure that:


of the avionics compartment. - the two forward dome-lights (7LS,
6LS) come on in the avionics
compartment,
- the lateral right dome-light (8LS)
comes on in the avionics compartment.

9. Close the right lateral door 822 Look through the access door 812:
of the avionics compartment. - You must get the same results as in
paragraph 7.

5. Close-up
________

Subtask 33-35-00-410-050

A. Close Access

(1) Close the lateral left door 812 of the avionics compartment.

(2) Remove the access platform(s).

Subtask 33-35-00-862-051

B. De-energize the aircraft electrical circuits


(Ref. TASK 24-41-00-862-002).



EFF :

ALL  33-35-00

Page 504
May 01/06
R  
IAC 
______________________________________________________________
LIGHT - DOME, AVIONICS COMPARTMENT (6LS,7LS,8LS,9LS,10LS,22LS)
____________________
REMOVAL/INSTALLATION

TASK 33-35-11-000-002

Removal of the Avionics-Compartment Dome Lights (6LS, 7LS, 8LS, 9LS, 10LS,
22LS)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
FOR FIN 6LS, 7LS
No specific access platform 1.6 m (5 ft. 3 in.)
FOR FIN 8LS
No specific access platform 1.6 m (5 ft. 3 in.)
FOR FIN 10LS, 9LS
No specific access platform 1.6 m (5 ft. 3 in.)
FOR FIN 22LS
No specific access platform 1.6 m (5 ft. 3 in.)



EFF :

ALL  33-35-11

Page 401
Feb 01/96
 
IAC 
B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 001-010,

33-35-11-991-001 Fig. 401

R **ON A/C 011-012, 014-099, 101-199, 901-999,

33-35-11-991-001-A Fig. 401A

**ON A/C ALL

3. __________
Job Set-up

Subtask 33-35-11-865-053

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/AVNCS COMPT/DOME 1LS Z07

Subtask 33-35-11-010-051

B. Get access to the Avionics Compartment


FOR 6LS, 7LS
- put the access platform in position at zone 121,
- open the door 811.
FOR 8LS
- put the access platform in position at zone 124,
- open the door 822.
FOR 9LS, 10LS
- put the access platform in position at zone 128,
- open the door 824.
FOR 22LS
- put the access platform in position at zone 123,
- open the door 812.



EFF :

ALL  33-35-11

Page 402
Feb 01/07
 
IAC 
4. Procedure
_________

**ON A/C 001-010,

(Ref. Fig. 401/TASK 33-35-11-991-001)

R **ON A/C 011-012, 014-099, 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-35-11-991-001-A)

**ON A/C 001-010,

Subtask 33-35-11-020-052

A. Removal of the bulb

(1) Loosen the six screws (7). During this operation, hold the cover (6).

(2) Remove the cover (6).

(3) Remove the bulb (8).

Subtask 33-35-11-020-053

B. Removal of the dome light

(1) Loosen the four screws (1) and the washers (2).
During this operation hold the dome light (4).

(2) Disconnect the electrical connectors (5).

(3) Put the blanking caps on the electrical connectors (5).

(4) Remove the dome light support (4).



EFF :

ALL  33-35-11

Page 403
Feb 01/07
 
IAC 
Avionics-Compartment Dome Lights
Figure 401/TASK 33-35-11-991-001



EFF :

001-010,  33-35-11

Page 404
Feb 01/96
 
IAC 
Avionics-Compartment Dome Lights
Figure 401A/TASK 33-35-11-991-001-A


R

EFF :

011-012, 014-099, 101-199, 901-999,  33-35-11

Page 405
Feb 01/07
 
IAC 
R **ON A/C 011-012, 014-099, 101-199, 901-999,

Subtask 33-35-11-020-052-A

A. Removal of the bulb

(1) Loosen the three captive screws (7). During this operation, hold the
cover (6).

(2) Remove the cover (6).

(3) Remove the bulb (1).

Subtask 33-35-11-020-053-A

B. Removal of the dome light

(1) Loosen the three screws (2) from the housing (3).
During this operation hold the dome light (4).

(2) Disconnect the electrical connectors (5).

(3) Put the blanking caps on the electrical connectors (5).

(4) Remove the dome light support (4).


R

EFF :

011-012, 014-099, 101-199, 901-999,  33-35-11

Page 406
Feb 01/07
 
IAC 
**ON A/C ALL

TASK 33-35-11-400-002

Installation of the Avionics-Compartment Dome Lights (6LS, 7LS, 8LS, 9LS, 10LS,
22LS)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

FOR FIN 6LS, 7LS


No specific access platform 1.6 m (5 ft. 3 in.)
FOR FIN 8LS
No specific access platform 1.6 m (5 ft. 3 in.)
FOR FIN 10LS, 9LS
No specific access platform 1.6 m (5 ft. 3 in.)
FOR FIN 22LS
No specific access platform 1.6 m (5 ft. 3 in.)

B. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

1 bulb 33-35-11 01A-060


8 bulb 33-35-11 01A-060



EFF :

ALL  33-35-11

Page 407
May 01/02
R  
IAC 
C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-35-00-720-001 Functional Test of the Avionics-Compartment Lighting

**ON A/C 001-010,

33-35-11-991-001 Fig. 401

R **ON A/C 011-012, 014-099, 101-199, 901-999,

33-35-11-991-001-A Fig. 401A


FOR FIN 10LS, 9LS
52-41-00-410-002 Close the Avionics Compartment Doors after Access

**ON A/C ALL

3. __________
Job Set-up

Subtask 33-35-11-865-054

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/AVNCS COMPT/DOME 1LS Z07

Subtask 33-35-11-010-052

B. Get access to the Avionics Compartment


FOR 6LS, 7LS
- make sure that the access platform is in position at the zone 121,
- make sure that the door 811 is open.
FOR 8LS
- make sure that the access platform is in position at the zone 124,
- make sure that the door 822 is open.
FOR 9LS, 10LS
- make sure that the access platform is in position at the zone 128,
- make sure that the door 824 is open.



EFF :

ALL  33-35-11

Page 408
Feb 01/07
 
IAC 
FOR 22LS
- make sure that the access platform is in position at the zone 123,
- make sure that the door 812 is open.

4. Procedure
_________

**ON A/C 001-010,

(Ref. Fig. 401/TASK 33-35-11-991-001)

R **ON A/C 011-012, 014-099, 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-35-11-991-001-A)

**ON A/C 001-010,

Subtask 33-35-11-420-052

A. Installation of the dome light

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Remove the blanking caps from the electrical connectors.


(5).

(4) Install a new dome light (4) in its housing (3).


Hold it in this position.

(5) Lock the new dome light (4) with the four screws (1) and the washers
(2).

(6) Make sure that the electrical connectors (5) are in the correct
condition.

(7) Connect the electrical connectors (5).



EFF :

ALL  33-35-11

Page 409
Feb 01/07
 
IAC 
Subtask 33-35-11-420-053

B. Installation of the bulb

(1) Install a new bulb (8).

(2) Put the cover (6) in position on the dome light (4).
Hold it in this position.

(3) Lock the cover (6) with the six screws (7).

R **ON A/C 011-012, 014-099, 101-199, 901-999,

Subtask 33-35-11-420-052-A

A. Installation of the dome light

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Remove the blanking caps from the electrical connectors.


(5).

(4) Install a new dome light (4) in its housing (3).


Hold it in this position.

(5) Lock the new dome light (4) with the three screws (2).

(6) Make sure that the electrical connectors (5) are in the correct
condition.

(7) Connect the electrical connectors (5).

Subtask 33-35-11-420-053-A

B. Installation of the bulb

(1) Install a new bulb (1).

(2) Put the cover (6) in position on the dome light (4).
Hold it in this position.

(3) Lock the cover (6) with the three captive screws (7).



EFF :

ALL  33-35-11

Page 410
Feb 01/07
 
IAC 
**ON A/C ALL

Subtask 33-35-11-865-055

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LS.

Subtask 33-35-11-720-051

D. Functional Test of the Avionics-Compartment Dome Lights

(1) Do the functional test of the avionics-Compartment Lighting


(Ref. TASK 33-35-00-720-001).

5. Close-up
________

Subtask 33-35-11-410-051

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Close the avionics compartment doors


- FOR 6LS, 7LS
close the door 811,
- FOR 8LS
close the door 822,
- FOR 9LS, 10LS
R close the door 824, (Ref. TASK 52-41-00-410-002)
- FOR 22LS
812 close the door.

(3) Remove the access platform(s).



EFF :

ALL  33-35-11

Page 411
May 01/02
 
IAC 
WHEEL WELL LIGHTING - DESCRIPTION AND OPERATION
_______________________________________________

1. General
_______
R
The wheel well lighting-system has the lighting of the main wheel wells and
the hydraulic compartment. For maintenance practices an electrical outlet is
installed at the front wheel well and in the hydraulic compartment.
R

2. __________________
Component Location
R

R **ON A/C 001-012, 014-099,

(Ref. Fig. 001)

R **ON A/C 101-199, 901-999,

R (Ref. Fig. 001A)

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,


R Post SB 92-1032 For A/C 001-012,014-099,

R (Ref. Fig. 001B)

R **ON A/C ALL

-------------------------------------------------------------------------------
FIN FUNCTIONAL DESIGNATION PANEL ZONE ACCESS ATA
DOOR REF.
-------------------------------------------------------------------------------
3LL OUTLET - 28 V DC NOSEWHEEL WELL COMPT RH 123
4LL OUTLET - 28 V DC HYDR. COMPT. 2025VU 191
7LL WHEEL WELL LIGHT LH 147 33-37-11
8LL WHEEL WELL LIGHT RH 148 33-37-11
9LL HYDR. COMPT. LIGHT LH 195 33-37-11
10LL HYDR. COMPT. LIGHT RH 196 33-37-11
12LL TOGGLE SWITCH - HYDR. COMPT. 2025VU 191

3. __________________
System Description



EFF :

ALL  33-37-00

Page 1
May 01/07
 
IAC 
Wheel Well Lighting - Component Location
Figure 001


R

EFF :

001-012, 014-099,  33-37-00

Page 2
May 01/06
 
IAC 
Wheel Well Lighting - Component Location
Figure 001A


R

EFF :

101-199, 901-999,  33-37-00

Page 3
May 01/07
 
IAC 
R Wheel Well Lighting - Component Location
R Figure 001B


R

EFF :

001-012, 014-099,  33-37-00

Page 4
May 01/07
 
IAC 
R

R **ON A/C 001-012, 014-099,

(Ref. Fig. 002)

R **ON A/C 101-199, 901-999,

R (Ref. Fig. 002A)

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,


R Post SB 92-1032 For A/C 001-012,014-099,

R (Ref. Fig. 002B)

R **ON A/C ALL

One dome light is installed in each of the main-wheel well compartments. Two
dome lights are installed in the hydraulic compartments LH and RH. The
R busbar 202PP supplies 28VDC to all four lights through the circuit breaker
R 2LL and the control switch 12LL. An outlet 3LL is installed in the nosewheel
well for maintenance purposes. Another outlet 4LL is installed in the
hydraulic compartment, adjacent to the control switch 12LL, on panel 2025VU.
When the control switch is set to the ON position, all lights come on.
R


R

EFF :

ALL  33-37-00

Page 5
May 01/07
 
IAC 
Wheel Well Lighting - Schematic
Figure 002


R

EFF :

001-012, 014-099,  33-37-00

Page 6
May 01/07
 
IAC 
Wheel Well Lighting - Schematic
Figure 002A


R

EFF :

101-199, 901-999,  33-37-00

Page 7
Feb 01/07
 
IAC 
R Wheel Well Lighting - Schematic
R Figure 002B



EFF :

001-012, 014-099,  33-37-00

Page 8
May 01/07
 
IAC 
WHEEL WELL LIGHTING - ADJUSTMENT/TEST
_____________________________________

TASK 33-37-00-710-001

Operational Test of the Wheel Well Lighting

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

1. __________________
Reason for the Job

To make sure that the wheel well lighting operates correctly.

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

460005835 2 GROUND LOCK SLEEVE


FOR FIN 12LL
No specific warning notice

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
29-10-00-863-002 Pressurize the Yellow Hydraulic System
29-10-00-864-001 Depressurize the Green Hydraulic System
29-10-00-864-002 Depressurize the Yellow Hydraulic System
29-10-00-864-003 Depressurize the Blue Hydraulic System
32-12-00-010-001 Open the Main Gear Doors for Access



EFF :

ALL  33-37-00

Page 501
Feb 01/96
 
IAC 
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

32-12-00-410-001 Close the Main Gear Doors after Access

3. __________
Job Set-up

Subtask 33-37-00-861-050

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-37-00-865-050

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/WHL WELL/LTG/DOME 2LL X08

Subtask 33-37-00-010-050

C. Get Access

(1) Open the main gear doors for access (Ref. TASK 32-12-00-010-001).

(2) Depressurize the Green, Yellow and Blue hydraulic systems (Ref. TASK
29-10-00-864-001) (Ref. TASK 29-10-00-864-002) (Ref. TASK 29-10-00-
864-003).

(3) Install the GROUND LOCK SLEEVE on the main-gear door actuator.

FOR 12LL

(4) Open the access panel 191MB.

(5) Put the warning notice in position.



EFF :

ALL  33-37-00

Page 502
Aug 01/06
 
IAC 
4. Procedure
_________

Subtask 33-37-00-710-050

A. Test of the Wheel Well Lighting

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the electrical combination In the MLG wheel well:


panel 2025VU:
- set the control switch 12LL to - the wheel well lights 7LL and 8LL
the ON position. come on.
In the hydraulic compartment:
- the hydraulic compartment lights 9LL
and 10LL come on.

- set the control switch 12LL to - the hydraulic compartment lights 9LL
the OFF position. and 10LL go off.
In the MLG wheel well:
- the wheel well lights 7LL and 8LL go
off.

5. Close-up
________

Subtask 33-37-00-410-050

A. Close Access

(1) Remove the GROUND LOCK SLEEVE from the main-gear door actuator
(Ref. TASK 32-12-00-410-001).

(2) Pressurize the Yellow hydraulic system to close the main gear doors
(Ref. TASK 29-10-00-863-002).

(3) Close the main gear doors (Ref. TASK 32-12-00-410-001).

(4) Close the access panel 191MB.

(5) Remove the warning notice(s).

(6) Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-37-00

Page 503
May 01/07
 
IAC 
INTENTIONALLY BLANK


R



 33-37-00

Page 504
May 01/07
 
IAC 
Subtask 33-37-00-862-050

B. De-energize the aircraft electrical circuit (Ref. TASK 24-41-00-862-002).



EFF :

ALL  33-37-00

Page 505
May 01/06
R  
IAC 
TASK 33-37-00-720-001

Functional Test of the Maintenance Sockets

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

WARNING : MAKE SURE THAT THE NLG DOWNLOCK SAFETY PIN AND THE TWO DOOR SAFETY
_______
PINS ARE INSTALLED.

1. __________________
Reason for the Job

To make sure that the maintenance sockets operate correctly.

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

98D32203502000 1 SAFETY PIN - NLG DOOR


FOR FIN 3LL
No specific stepladder 2.0 m (6 ft. 7 in.)
FOR FIN 4LL
No specific multimeter

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
29-10-00-864-001 Depressurize the Green Hydraulic System
29-10-00-864-002 Depressurize the Yellow Hydraulic System
29-10-00-864-003 Depressurize the Blue Hydraulic System
32-22-00-010-001 Nose Gear Doors - Ground Doors Opening
32-22-00-410-001 Nose Gear Doors - Ground Doors Closing



EFF :

ALL  33-37-00

Page 506
May 01/06
R  
IAC 
3. __________
Job Set-up

Subtask 33-37-00-861-051

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-37-00-865-051

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/WHL WELL/LTG/OUT 1LL X07

Subtask 33-37-00-010-052

C. Get Access

(1) Open the nose gear doors for access (Ref. TASK 32-22-00-010-001).

(2) Depressurize the Green, Yellow and Blue hydraulic systems (Ref. TASK
29-10-00-864-001) (Ref. TASK 29-10-00-864-002) (Ref. TASK 29-10-00-
864-003).

(3) Install the SAFETY PIN - NLG DOOR on the nose gear doors.

FOR 3LL

(4) Put the stepladder in position in zone 123.

FOR 4LL

(5) Open the access panel 191MB.

(6) Use the multimeter for this test.



EFF :

ALL  33-37-00

Page 507
Aug 01/06
 
IAC 
4. Procedure
_________

Subtask 33-37-00-720-050

A. Test of the Maintenance Sockets

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the electrical combination On the multimeter:


panel 2025VU:
- measure the output voltage - the output voltage is 28 V DC.
between the connections + and N
on the maintenance socket 4LL.

2. In the nose wheel well On the multimeter:


compartment zone 123:
- measure the output voltage - the output voltage is 28 V DC.
between the connections + and N
on the maintenance socket 3LL.

5. Close-up
________

Subtask 33-37-00-410-051

A. Close Access

(1) Remove the multimeter.

(2) Remove the SAFETY PIN - NLG from the nose gear door (Ref. TASK 32-22-
00-410-001).

(3) Remove the stepladder.

(4) Pressurize the Yellow hydraulic system to close the nose gear doors.

(5) Make sure that the work area is clean and clear of tool(s) and other
items.

(6) Close the nose gear doors (Ref. TASK 32-22-00-410-001).

FOR 4LL

(7) Close the access panel 191MB.



EFF :

ALL  33-37-00

Page 508
May 01/06
R  
IAC 
Subtask 33-37-00-862-051

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-37-00

Page 509
May 01/06
 
IAC 
LIGHT - DOME, MLG L AND R WELL (7LL,8LL) - REMOVAL/INSTALLATION
_______________________________________________________________

**ON A/C 001-012, 014-099,

TASK 33-37-11-000-001

R Removal of the MLG Dome Light (HELLA)

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

R NOTE : The procedure is the same for all MLG dome lights (HELLA).
____

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

R No specific blanking caps


No specific circuit breaker(s) safety clip(s)
R FOR FIN 7LL
R No specific 1 ACCESS PLATFORM 2M (6 FT)
R FOR FIN 8LL
R No specific 1 ACCESS PLATFORM 2M (6 FT)
R FOR FIN 9LL
R No specific 1 ACCESS PLATFORM 2M (6 FT)
R FOR FIN 10LL
R No specific 1 ACCESS PLATFORM 2M (6 FT)



EFF :

ALL  33-37-11

Page 401
May 01/07
 
IAC 
B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-37-11-991-001 Fig. 401

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,


R Post SB 92-1032 For A/C 001-012,014-099,

R 33-37-11-991-001-A Fig. 401A


R FOR FIN 7LL
R 32-12-00-010-001 Open the Main Gear Doors for Access
R FOR FIN 8LL
R 32-12-00-010-001 Open the Main Gear Doors for Access

R **ON A/C 001-012, 014-099,

3. __________
Job Set-up

Subtask 33-37-11-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/WHL WELL/LTG/DOME 2LL X08

Subtask 33-37-11-010-050

B. Get Access
R

R (1) Open the applicable access door/panel:


R FOR 7LL
R - Open the left MLG door 734 (Ref. TASK 32-12-00-010-001).
R - Put the ACCESS PLATFORM 2M (6 FT) in position at zone 147.
R FOR 8LL
R - Open the right MLG door 744 (Ref. TASK 32-12-00-010-001).
R - Put the ACCESS PLATFORM 2M (6 FT) in position at zone 148.
R FOR 9LL
R - Open the access panel 195BB.



EFF :

001-012, 014-099,  33-37-11

Page 402
May 01/07
 
IAC 
R - Put the ACCESS PLATFORM 2M (6 FT) in position at zone 195.
R FOR 10LL
R - Open the access panel 196BB.
R - Put the ACCESS PLATFORM 2M (6 FT) in position at zone 196.

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,


R Post SB 92-1032 For A/C 001-012,014-099,

R Subtask 33-37-11-010-050-A

R B. Get Access

R (1) Open the applicable access door:


R FOR 7LL
R - Open the left MLG door 734 (Ref. TASK 32-12-00-010-001).
R - Put the ACCESS PLATFORM 2M (6 FT) in position at zone 147.
R FOR 8LL
R - Open the right MLG door 744 (Ref. TASK 32-12-00-010-001).
R - Put the ACCESS PLATFORM 2M (6 FT) in position at zone 148.

R **ON A/C 001-012, 014-099,

4. Procedure
_________

(Ref. Fig. 401/TASK 33-37-11-991-001)

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,


R Post SB 92-1032 For A/C 001-012,014-099,

R (Ref. Fig. 401A/TASK 33-37-11-991-001-A)

R **ON A/C 001-012, 014-099,

Subtask 33-37-11-020-050

R A. Removal of the MLG Dome Light

(1) Find the MLG dome light.

(2) Support the dome light (1).



EFF :

001-012, 014-099,  33-37-11

Page 403
May 01/07
 
IAC 
R MLG Dome Light
Figure 401/TASK 33-37-11-991-001



EFF :

001-012, 014-099,  33-37-11

Page 404
May 01/07
 
IAC 
R MLG Dome Light
R Figure 401A/TASK 33-37-11-991-001-A



EFF :

001-012, 014-099,  33-37-11

Page 405
May 01/07
 
IAC 
(3) Remove the screws (2) and the washers (3).

R (4) Remove the nuts (4) and the washers (5).

R (5) Remove the electrical connectors (6).

R (6) Put blanking caps on the disconnected electrical connectors.

R (7) Remove the dome light (1).


R

EFF :

001-012, 014-099,  33-37-11

Page 406
May 01/07
 
IAC 
TASK 33-37-11-400-001

R Installation of the MLG Dome Light (HELLA)

R WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
R YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

R NOTE : The procedure is the same for all MLG dome lights (HELLA).
____

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-37-00-710-001 Operational Test of the Wheel Well Lighting


33-37-11-991-001 Fig. 401

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,


R Post SB 92-1032 For A/C 001-012,014-099,

R 33-37-11-991-001-A Fig. 401A


R FOR FIN 7LL
R 32-12-00-410-001 Close the Main Gear Doors after Access
R FOR FIN 8LL
R 32-12-00-410-001 Close the Main Gear Doors after Access


R

EFF :

001-012, 014-099,  33-37-11

Page 407
May 01/07
 
IAC 
R **ON A/C 001-012, 014-099,

3. __________
Job Set-up

Subtask 33-37-11-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/WHL WELL/LTG/DOME 2LL X08

4. Procedure
_________

(Ref. Fig. 401/TASK 33-37-11-991-001)

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,


R Post SB 92-1032 For A/C 001-012,014-099,

R (Ref. Fig. 401A/TASK 33-37-11-991-001-A)

R **ON A/C 001-012, 014-099,

Subtask 33-37-11-420-050

A. Installation of the MLG Dome Light.

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

R (3) Remove the blanking caps from the electrical connectors.

R (4) Support the MLG dome light (1) and install the electrical connectors
R (6) with the washers (5) and the nuts (4).

R (5) Install the MLG dome light (1) with the washers (3) and the screws
(2).


R

EFF :

001-012, 014-099,  33-37-11

Page 408
May 01/07
 
IAC 
Subtask 33-37-11-865-052

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
2LL.

Subtask 33-37-11-710-050

C. Do the operational test of the wheel well lights (Ref. TASK 33-37-00-710-
001).

5. Close-up
________

Subtask 33-37-11-410-050

A. Close Access
R

R (1) Make sure that the work area is clean and clear of tool(s) and other
items.

R (2) Remove the access platform(s).

R (3) Close the applicable access door/panel:


R FOR 7LL
R - Close the left MLG door 734 (Ref. TASK 32-12-00-410-001).
R FOR 8LL
R - Close the right MLG door 744 (Ref. TASK 32-12-00-410-001).
R FOR 9LL
R - Close the access panel 195BB.
R FOR 10LL
R - Close the access panel 196BB.

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,


R Post SB 92-1032 For A/C 001-012,014-099,

R Subtask 33-37-11-410-050-A

R A. Close Access

R (1) Make sure that the work area is clean and clear of tool(s) and other
R items.

R (2) Remove the access platform(s).


R

EFF :

001-012, 014-099,  33-37-11

Page 409
May 01/07
 
IAC 
R (3) Close the applicable access door:
R FOR 7LL
R - Close the left MLG door 734 (Ref. TASK 32-12-00-410-001).
R FOR 8LL
R - Close the right MLG door 744 (Ref. TASK 32-12-00-410-001).


R

EFF :

001-012, 014-099,  33-37-11

Page 410
May 01/07
 
IAC 
**ON A/C ALL

TASK 33-37-11-000-002

R Removal of the Lamp(s) of the MLG Dome Light (AIRSIGNA)

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

R NOTE : The procedure is the same for all MLG dome lights (AIRSIGNA).
____

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


FOR FIN 7LL
No specific 1 ACCESS PLATFORM 2M (6 FT)
FOR FIN 8LL
No specific 1 ACCESS PLATFORM 2M (6 FT)
FOR FIN 9LL
No specific 1 ACCESS PLATFORM 2M (6 FT)
FOR FIN 10LL
No specific 1 ACCESS PLATFORM 2M (6 FT)



EFF :

ALL  33-37-11

Page 411
May 01/07
 
IAC 
B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R **ON A/C 101-199, 901-999,

33-37-11-991-002 Fig. 402

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,

R 33-37-11-991-002-A Fig. 402A


FOR FIN 7LL
32-12-00-010-001 Open the Main Gear Doors for Access
FOR FIN 8LL
32-12-00-010-001 Open the Main Gear Doors for Access
R

**ON A/C ALL

3. __________
Job Set-up

**ON A/C ALL

Post SB 33-1044 For A/C 001-012,014-099,

Subtask 33-37-11-865-053

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/WHL WELL/LTG/DOME 2LL X08



EFF :

ALL  33-37-11

Page 412
May 01/07
 
IAC 
R **ON A/C 101-199, 901-999,

Subtask 33-37-11-010-052

B. Get Access

R (1) Open the applicable access door/panel:


R
FOR 7LL
R - Open the left MLG door 734 (Ref. TASK 32-12-00-010-001).
R
R - Put the ACCESS PLATFORM 2M (6 FT) in position at zone 147.
R
FOR 8LL
R - Open the right MLG door 744 (Ref. TASK 32-12-00-010-001).
R
R - Put the ACCESS PLATFORM 2M (6 FT) in position at zone 148.
R
FOR 9LL
R - Open the access panel 195BB.
R
R - Put the ACCESS PLATFORM 2M (6 FT) in position at zone 195.
R
FOR 10LL
R - Open the access panel 196BB.
R
R - Put the ACCESS PLATFORM 2M (6 FT) in position at zone 196.

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,

R Subtask 33-37-11-010-052-A

R B. Get Access

R (1) Open the applicable access panel:


R FOR 9LL
R - Open the access panel 195BB.
R - Put the ACCESS PLATFORM 2M (6 FT) in position at zone 195.
R FOR 10LL
R - Open the access panel 196BB.
R - Put the ACCESS PLATFORM 2M (6 FT) in position at zone 196.



EFF :

ALL  33-37-11

Page 413
May 01/07
 
IAC 
**ON A/C ALL

4. Procedure
_________

R **ON A/C 101-199, 901-999,

(Ref. Fig. 402/TASK 33-37-11-991-002)

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,

R (Ref. Fig. 402A/TASK 33-37-11-991-002-A)

R **ON A/C ALL

R Post SB 33-1044 For A/C 001-012,014-099,

Subtask 33-37-11-020-052

R A. Removal of the Lamp(s) of the MLG Dome Light

(1) Loosen the captive screws (4) and remove the cover assembly (3).

NOTE : The lens is bonded in the cover assembly and cannot be


____
replaced.

R (2) Remove the lamp(s) (2) from the light assembly (5) and discard the
R lamp(s).



EFF :

ALL  33-37-11

Page 414
May 01/07
 
IAC 
R MLG Dome Light
Figure 402/TASK 33-37-11-991-002


R

EFF :

101-199, 901-999,  33-37-11

Page 415
May 01/07
 
IAC 
R MLG Dome Light
R Figure 402A/TASK 33-37-11-991-002-A


R

EFF :

001-012, 014-099,  33-37-11

Page 416
May 01/07
 
IAC 
**ON A/C ALL

TASK 33-37-11-400-002

Installation of the Lamp(s) of the MLG Dome Light (AIRSIGNA)

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

NOTE : The procedure is the same for all MLG dome lights (AIRSIGNA).
____

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

FOR FIN 7LL


No specific 1 ACCESS PLATFORM 2M (6 FT)
FOR FIN 8LL
No specific 1 ACCESS PLATFORM 2M (6 FT)
FOR FIN 9LL
No specific 1 ACCESS PLATFORM 2M (6 FT)
FOR FIN 10LL
No specific 1 ACCESS PLATFORM 2M (6 FT)

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R Material No. 05-002 USA MIL-PRF-8116


PUTTY, ZINC CHROMATE GENERAL PURPOSE (Ref. 20-31-00)



EFF :

ALL  33-37-11

Page 417
Feb 01/08
 
IAC 
C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-37-00-710-001 Operational Test of the Wheel Well Lighting

**ON A/C 101-199, 901-999,

33-37-11-991-002 Fig. 402

**ON A/C 001-012, 014-099,

Post SB 33-1044 For A/C 001-012,014-099,

33-37-11-991-002-A Fig. 402A


FOR FIN 7LL
32-12-00-010-001 Open the Main Gear Doors for Access
32-12-00-410-001 Close the Main Gear Doors after Access
FOR FIN 8LL
32-12-00-010-001 Open the Main Gear Doors for Access
32-12-00-410-001 Close the Main Gear Doors after Access

**ON A/C ALL

3. __________
Job Set-up

**ON A/C ALL

Post SB 33-1044 For A/C 001-012,014-099,

Subtask 33-37-11-865-054

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/WHL WELL/LTG/DOME 2LL X08



EFF :

ALL  33-37-11

Page 418
Feb 01/08
R  
IAC 
R **ON A/C 101-199, 901-999,

Subtask 33-37-11-860-050

B. Aircraft Maintenance Configuration

R (1) Make sure, that the applicable access door/panel is open:


R
FOR 7LL
R - Make sure, that the left MLG door 734 is open (Ref. TASK 32-12-00-
010-001).
R
R - Make sure, that the ACCESS PLATFORM 2M (6 FT) is in position at
R zone 147.
R
FOR 8LL
R - Make sure, that the right MLG door 744 is open (Ref. TASK 32-12-00-
010-001).
R
R - Make sure, that the ACCESS PLATFORM 2M (6 FT) is in position at
R zone 148.
R
FOR 9LL
R - Make sure, that the access panel 195BB is open.
R
R - Make sure, that the ACCESS PLATFORM 2M (6 FT) is in position at
R zone 195.
FOR 10LL
R - Make sure, that the access panel 196BB is open.
R
R - Make sure, that the ACCESS PLATFORM 2M (6 FT) is in position at
R zone 196.

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,

R Subtask 33-37-11-860-050-A

R B. Aircraft Maintenance Configuration

R (1) Make sure, that the applicable access panel is open:


R FOR 9LL
R - Make sure, that the access panel 195BB is open.
R - Make sure, that the ACCESS PLATFORM 2M (6 FT) is in position at
R zone 195.



EFF :

ALL  33-37-11

Page 419
May 01/07
 
IAC 
R FOR 10LL
R - Make sure, that the access panel 196BB is open.
R - Make sure, that the ACCESS PLATFORM 2M (6 FT) is in position at
R zone 196.

**ON A/C ALL

4. Procedure
_________

R **ON A/C 101-199, 901-999,

(Ref. Fig. 402/TASK 33-37-11-991-002)

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,

R (Ref. Fig. 402A/TASK 33-37-11-991-002-A)

R **ON A/C ALL

R Post SB 33-1044 For A/C 001-012,014-099,

Subtask 33-37-11-420-051

R A. Installation of the Lamp(s) of the MLG Dome Light

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED
_______
BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.

NOTE : When it is necessary to replace one lamp, it is recommended that


____
you replace the second lamp at the same time.

R (1) Put the lamp(s) (2) in the light assembly (5) and turn it clockwise
R to lock the lamp(s) in position.

(2) Correctly align the cover assembly (3) with the screw holes of the
housing (1).



EFF :

ALL  33-37-11

Page 420
May 01/07
 
IAC 
(3) Apply the SPECIAL MATERIALS (Material No. 05-002) to the captive
screws (4).

(4) Install the captive screws (4) and tighten.

Subtask 33-37-11-865-055

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
2LL.

Subtask 33-37-11-710-051

C. Do the operational test of the wheel well lights (Ref. TASK 33-37-00-710-
001).

**ON A/C ALL

5. Close-up
________

R **ON A/C 101-199, 901-999,

Subtask 33-37-11-410-051

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

R (2) Remove the access platform(s).

R (3) Close the applicable access door/panel:


R
FOR 7LL
R - Close the left MLG door 734 (Ref. TASK 32-12-00-410-001).
R
FOR 8LL
R - Close the right MLG door 744 (Ref. TASK 32-12-00-410-001).
R
R FOR 9LL
R - Close the access panel 195BB.
R FOR 10LL
R - Close the access panel 196BB.



EFF :

ALL  33-37-11

Page 421
May 01/07
 
IAC 
R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,

R Subtask 33-37-11-410-051-A

R A. Close Access

R (1) Make sure that the work area is clean and clear of tool(s) and other
R items.

R (2) Remove the access platform(s).

R (3) Close the applicable access panel:


R FOR 9LL
R - Close the access panel 195BB.
R FOR 10LL
R - Close the access panel 196BB.


R

EFF :

001-012, 014-099,  33-37-11

Page 422
May 01/07
 
IAC 
**ON A/C ALL

TASK 33-37-11-000-003

R Removal of the MLG Dome Light (AIRSIGNA)

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

R NOTE : The procedure is the same for all MLG dome lights (AIRSIGNA).
____

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
R FOR FIN 7LL
R No specific 1 ACCESS PLATFORM 2M (6 FT)
R FOR FIN 8LL
R No specific 1 ACCESS PLATFORM 2M (6 FT)
R FOR FIN 9LL
R No specific 1 ACCESS PLATFORM 2M (6 FT)
R FOR FIN 10LL
R No specific 1 ACCESS PLATFORM 2M (6 FT)



EFF :

ALL  33-37-11

Page 423
May 01/07
 
IAC 
B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R **ON A/C 101-199, 901-999,

33-37-11-991-003 Fig. 403

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,

R 33-37-11-991-003-A Fig. 403A


R FOR FIN 7LL
R 32-12-00-010-001 Open the Main Gear Doors for Access
R FOR FIN 8LL
R 32-12-00-010-001 Open the Main Gear Doors for Access

**ON A/C ALL

3. __________
Job Set-up

**ON A/C ALL

Post SB 33-1044 For A/C 001-012,014-099,

Subtask 33-37-11-865-056

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/WHL WELL/LTG/DOME 2LL X08



EFF :

ALL  33-37-11

Page 424
May 01/07
 
IAC 
R **ON A/C 101-199, 901-999,

Subtask 33-37-11-010-053

B. Get Access
R

R (1) Open the applicable access door/panel:


R FOR 7LL
R - Open the left MLG door 734 (Ref. TASK 32-12-00-010-001).
R - Put the ACCESS PLATFORM 2M (6 FT) in position at zone 147.
R FOR 8LL
R - Open the right MLG door 744 (Ref. TASK 32-12-00-010-001).
R - Put the ACCESS PLATFORM 2M (6 FT) in position at zone 148.
R FOR 9LL
R - Open the access panel 195BB.
R - Put the ACCESS PLATFORM 2M (6 FT) in position at zone 195.
R FOR 10LL
R - Open the access panel 196BB.
R - Put the ACCESS PLATFORM 2M (6 FT) in position at zone 196.

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,

R Subtask 33-37-11-010-053-A

R B. Get Access

R (1) Open the applicable access panel:


R FOR 9LL
R - Open the access panel 195BB.
R - Put the ACCESS PLATFORM 2M (6 FT) in position at zone 195.
R FOR 10LL
R - Open the access panel 196BB.
R - Put the ACCESS PLATFORM 2M (6 FT) in position at zone 196.



EFF :

ALL  33-37-11

Page 425
May 01/07
 
IAC 
**ON A/C ALL

4. Procedure
_________

R **ON A/C 101-199, 901-999,

(Ref. Fig. 403/TASK 33-37-11-991-003)

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,

R (Ref. Fig. 403A/TASK 33-37-11-991-003-A)

R **ON A/C ALL

R Post SB 33-1044 For A/C 001-012,014-099,

Subtask 33-37-11-020-053

A. Removal of the MLG Dome Light

R (1) Support the MLG dome light (1).

(2) Remove the screws (4) and the washers (5).

R (3) Move the MLG dome light (1) to get access to the electrical
R connectors (2) and (3).

(4) Disconnect the electrical connectors (2) and (3).


R

R (5) Remove the MLG dome light (1).

R (6) Put blanking caps on the disconnected electrical connectors.



EFF :

ALL  33-37-11

Page 426
May 01/07
 
IAC 
R MLG Dome Light
Figure 403/TASK 33-37-11-991-003



EFF :

101-199, 901-999,  33-37-11

Page 427
May 01/07
 
IAC 
R MLG Dome Light
R Figure 403A/TASK 33-37-11-991-003-A



EFF :

001-012, 014-099,  33-37-11

Page 428
May 01/07
 
IAC 
**ON A/C ALL

TASK 33-37-11-400-003

Installation of the MLG Dome Light (AIRSIGNA)

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

NOTE : The procedure is the same for all MLG dome lights (AIRSIGNA).
____

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

FOR FIN 7LL


No specific 1 ACCESS PLATFORM 2M (6 FT)
FOR FIN 8LL
No specific 1 ACCESS PLATFORM 2M (6 FT)
FOR FIN 9LL
No specific 1 ACCESS PLATFORM 2M (6 FT)
FOR FIN 10LL
No specific 1 ACCESS PLATFORM 2M (6 FT)

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R Material No. 05-002 USA MIL-PRF-8116


PUTTY, ZINC CHROMATE GENERAL PURPOSE (Ref. 20-31-00)



EFF :

ALL  33-37-11

Page 429
Feb 01/08
 
IAC 
C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-37-00-710-001 Operational Test of the Wheel Well Lighting

**ON A/C 101-199, 901-999,

33-37-11-991-003 Fig. 403

**ON A/C 001-012, 014-099,

Post SB 33-1044 For A/C 001-012,014-099,

33-37-11-991-003-A Fig. 403A


FOR FIN 7LL
32-12-00-010-001 Open the Main Gear Doors for Access
32-12-00-410-001 Close the Main Gear Doors after Access
FOR FIN 8LL
32-12-00-010-001 Open the Main Gear Doors for Access
32-12-00-410-001 Close the Main Gear Doors after Access

**ON A/C ALL

3. __________
Job Set-up

**ON A/C ALL

Post SB 33-1044 For A/C 001-012,014-099,

Subtask 33-37-11-865-057

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/WHL WELL/LTG/DOME 2LL X08



EFF :

ALL  33-37-11

Page 430
Feb 01/08
R  
IAC 
R **ON A/C 101-199, 901-999,

Subtask 33-37-11-860-051

B. Aircraft Maintenance Configuration


R

R (1) Make sure, that the applicable access door/panel is open:


R FOR 7LL
R - Make sure, that the left MLG door 734 is open (Ref. TASK 32-12-00-
010-001).
R - Make sure, that the ACCESS PLATFORM 2M (6 FT) is in position at
R zone 147.
R FOR 8LL
R - Make sure, that the right MLG door 744 is open (Ref. TASK 32-12-00-
010-001).
R - Make sure, that the ACCESS PLATFORM 2M (6 FT) is in position at
R zone 148.
R FOR 9LL
R - Make sure, that the access panel 195BB is open.
R - Make sure, that the ACCESS PLATFORM 2M (6 FT) is in position at
R zone 195.
R FOR 10LL
R - Make sure, that the access panel 196BB is open.
R - Make sure, that the ACCESS PLATFORM 2M (6 FT) is in position at
R zone 196.

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,

R Subtask 33-37-11-860-051-A

R B. Aircraft Maintenance Configuration

R (1) Make sure, that the applicable access panel is open:


R FOR 9LL
R - Make sure, that the access panel 195BB is open.
R - Make sure, that the ACCESS PLATFORM 2M (6 FT) is in position at
R zone 195.
R FOR 10LL
R - Make sure, that the access panel 196BB is open.
R - Make sure, that the ACCESS PLATFORM 2M (6 FT) is in position at
R zone 196.



EFF :

ALL  33-37-11

Page 431
May 01/07
 
IAC 
**ON A/C ALL

4. Procedure
_________

R **ON A/C 101-199, 901-999,

(Ref. Fig. 403/TASK 33-37-11-991-003)

R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,

R (Ref. Fig. 403A/TASK 33-37-11-991-003-A)

R **ON A/C ALL

R Post SB 33-1044 For A/C 001-012,014-099,

Subtask 33-37-11-420-052

A. Installation of the MLG Dome Light

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED
_______
BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Remove the blanking caps from the electrical connectors.

(4) Make sure that the electrical connectors are clean and in the correct
condition.

R (5) Hold the MLG dome light (1) at its correct installation position.

(6) Support the MLG dome light (1) and connect the electrical connectors
(2) and (3).

(7) Apply the SPECIAL MATERIALS (Material No. 05-002) to the washers (5)
and the screws (4).

(8) Install the MLG dome light (1) with the washers (5) and the screws
(4).



EFF :

ALL  33-37-11

Page 432
May 01/07
 
IAC 
(9) Tighten the screws (4).

Subtask 33-37-11-865-058

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
2LL.

Subtask 33-37-11-710-052

C. Do the operational test of the wheel well lights (Ref. TASK 33-37-00-710-
001).

**ON A/C ALL

5. Close-up
________

R **ON A/C 101-199, 901-999,

Subtask 33-37-11-410-052

A. Close Access
R

R (1) Make sure that the work area is clean and clear of tool(s) and other
items.

R (2) Remove the access platform(s).

R (3) Close the applicable access door/panel:


R FOR 7LL
R - Close the left MLG door 734 (Ref. TASK 32-12-00-410-001).
R FOR 8LL
R - Close the right MLG door 744 (Ref. TASK 32-12-00-410-001).
R FOR 9LL
R - Close the access panel 195BB.
R FOR 10LL
R - Close the access panel 196BB.



EFF :

ALL  33-37-11

Page 433
May 01/07
 
IAC 
R **ON A/C 001-012, 014-099,

R Post SB 33-1044 For A/C 001-012,014-099,

R Subtask 33-37-11-410-052-A

R A. Close Access

R (1) Make sure that the work area is clean and clear of tool(s) and other
R items.

R (2) Remove the access platform(s).

R (3) Close the applicable access panel:


R FOR 9LL
R - Close the access panel 195BB.
R FOR 10LL
R - Close the access panel 196BB.



EFF :

001-012, 014-099,  33-37-11

Page 434
May 01/07
 
IAC 
EXTERIOR - DESCRIPTION AND OPERATION
____________________________________

1. _______
General
The external lights provide the following illuminations:
- lights to illuminate the runway and the taxiway,
- lights to illuminate the wing leading edges and the engine nacelles,
- lights to give an indication of the aircraft position and to reduce
possible collision in the air or on the ground.

2. System
__________________
Description
The toggle switches on the overhead panel 25VU control the external lights
as follows:

A. Taxi and Takeoff Lights


(Ref. Fig. 001)
The taxi and takeoff lights provide illumination of the runway and the
taxiway.
Two lights are installed on the nose landing gear. The 400 W light is
switched on during the taxi phase. Both the 400 W and the 600 W light are
switched on during the takeoff phase.
A three position switch 4LR controls the lights.

B. Runway Turnoff Lights


(Ref. Fig. 001)
The runway turnoff lights provide illumination of the lateral areas of
the runway. Two lights are installed on the nose landing gear.
The toggle switch 2LC controls the lights.

C. Wing and Engine Scan Lights


(Ref. Fig. 001)
Two lights are installed, one on each side of the forward fuselage. They
illuminate the engine air intakes and the wing leading edges. It is
possible to examine these areas in flight; for example, to determine the
build up of ice.
The toggle switch 2LX controls the lights.

D. Navigation Light
(Ref. Fig. 002)
The dual navigation light system indicates the aircraft position and
direction.
It has:
- a red color light 9LA, incorporating two lamps, installed in the
left-hand wing-tip.
- a green color light 10LA, incorporating two lamps, installed in the
right-hand wing-tip.
- a white light 15LA, incorporating two lamps installed on the tail cone
at the extreme aft of the aircraft.



EFF :

ALL  33-40-00

Page 1
Feb 01/96
 
IAC 
External Lights - Component Location
Figure 001 (SHEET 1)



EFF :

ALL  33-40-00

Page 2
Feb 01/96
 
IAC 
External Lights - Component Location
Figure 001 (SHEET 2)



EFF :

ALL  33-40-00

Page 3
Feb 01/96
 
IAC 
External Lights - Component Location
Figure 001 (SHEET 3)



EFF :

ALL  33-40-00

Page 4
Feb 01/96
 
IAC 
INTENTIONALLY BLANK





 33-40-00

Page 5
Feb 01/96
 
IAC 
External Lights - Component Location
Figure 002 (SHEET 1)



EFF :

ALL  33-40-00

Page 6
Feb 01/96
 
IAC 
External Lights - Component Location
Figure 002 (SHEET 2)



EFF :

ALL  33-40-00

Page 7
Feb 01/96
 
IAC 
A three position switch, 3LA on the panel 25VU, controls the lights.

E. Landing Lights
(Ref. Fig. 003)
The landing light system provides lighting to illuminate the runway when
the aircraft lands at night.
Two landing lights 7LB and 8LB are installed one on the underside of each
wing. Each light has a separate control switch 5LB and 6LB.
They can be extended at all aircraft speeds.

F. Anticollision/Beacon Lights
(Ref. Fig. 002)
Two anticollision/beacon lights are installed, 7LV on the top and 6LV on
the bottom of the aircraft fuselage. The anticollision/beacon lights are
high intensity red discharge lamps. Each lamp is supplied from an
individual power unit. The anticollision/beacon lights flash at approx.
60 flashes per minute, when the BEACON switch 2LV is in the ON position.
Three strobe lights are installed, two at each wing tip on the leading
edges 16LV and 17LV and one on the tail cone 19LV. The strobe lights are
high intensity white lights synchronized to operate alternately with the
anticollision/beacon light. The forward facing strobe lights flash at
approx. 120 flashes per minute and the rearward facing strobe light
flashes at approx. 60 flashes per minute. This occures when the STROBE
switch 11LV is either in the ON or AUTO position.

G. Logo Lights
(Ref. Fig. 002)
Two logo lights, 3LY in the left and 4LY in the right, are installed in
the horizontal stabilizers. They light up the airlines logo on the fin
when:
- the aircraft is in the landing phase of the flight,
- the aircraft is taxiing,
- the aircraft is in the take off phase of the flight.
A three position switch, 3LA on the panel 25VU, controls the logo lights
together with the navigation lights.



EFF :

ALL  33-40-00

Page 8
Feb 01/96
 
IAC 
External Lights - Component Location
Figure 003



EFF :

ALL  33-40-00

Page 9
Feb 01/96
 
IAC 
NAVIGATION LIGHTS - DESCRIPTION AND OPERATION
_____________________________________________

1. _______
General
The Navigation Light system gives an external, visual indication of the
position of the aircraft and its direction of flight.

2. Component
__________________
Location
R (Ref. Fig. 001)

-------------------------------------------------------------------------------
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
9LA LT-NAVIGATION, L WING TIP 534 534 33-41-11
10LA LT-NAVIGATION, R WING TIP 634 634 33-41-11
13LA XFMR-TAIL NAVIGATION LIGHT 317 317AL 33-41-16
15LA LT-NAVIGATION, TAIL 317 317 33-41-15

3. System
__________________
Description
R (Ref. Fig. 001)
A forward-facing navigation light assembly is installed at the leading edge
of each wing tip. A rearward-facing navigation light assembly is installed
on the tail cone, below the APU exhaust. Each light assembly has a different
colored lens:
- the left wing-tip navigation light 9LA has a red lens
- the right wing-tip navigation light 10LA has a green lens
- the tail navigation light 15LA has a clear lens.

The navigation lights are controlled by the toggle switch 3LA which is
installed on the overhead panel 25VU in the cockpit. The switch has three
positions, which are identified NAV & LOGO 2/1/OFF.

4. Power
____________
Supply
R (Ref. Fig. 002)
The SERVICE BUS 2, 216XP supplies the navigation light systems 1 and 2 with
115V AC 400Hz. The power is supplied to each system through the related
circuit breakers 1LA and 2LA. These circuit breakers are installed on the
panel 122VU in the cockpit. Relays 6LA and 7LA connect the supply to the
step-down transformers of the related navigation lights. These relays are
installed on the panel 103VU.

5. Interface
_________



EFF :

ALL  33-41-00

Page 1
Nov 01/04
 
IAC 
Navigation Lights - Component Location
Figure 001



EFF :

ALL  33-41-00

Page 2
Feb 01/96
 
IAC 
Navigation Lights - Schematic
Figure 002



EFF :

ALL  33-41-00

Page 3
Feb 01/96
 
IAC 
6. Component
_____________________
Description
R (Ref. Fig. 001)

A. Forward-Facing Navigation Light 9LA(10LA)

Each forward-facing navigation light assembly contains two light units


which operate independently. Each light unit contains:
- a step-down transformer
- a 28V AC, 50 WATT, halogen lamp.

B. Rearwards-Facing Navigation Light 15LA

The rearwards-facing navigation light assembly contains two light units


which operate independently. Each light unit has a 12V AC, 25 WATT,
quartz lamp.
The related step-down transformer assembly 13LA contains two step-down
transformers, which operate independently to supply their related light
unit. This step-down transformer assembly is installed near the
navigation light assembly, in the tail cone.

7. Operation/Control
________________________________
and Indicating
R (Ref. Fig. 001)
With the switch 3LA set to position 1, the 115V AC SERVICE BUS 2, 216XP
supplies power through:
- the circuit breaker 1LA
- the switch 3LA (to energize the relay 6LA)
- the relay 6LA to the step-down transfomers of the related navigation
lights.
R
The step-down transformers in the wing-tip navigation light assemblies
supply 28V AC to the related lamp. The lamp comes on.
Each step-down transformer in the step-down transformer assembly 13LA
supplies 12V AC to its related tail navigation light. The lamp comes on.
With the switch 3LA set to position 2, the operation is almost the same, but
this time the power is supplied through the circuit breaker 2LA and the
relay 7LA.

With the switch 3LA set to OFF:


- the relays 6LA and 7LA are de-energized
- the lamps go off.



EFF :

ALL  33-41-00

Page 4
Nov 01/04
 
IAC 
NAVIGATION LIGHTS - DEACTIVATION/REACTIVATION
_____________________________________________

TASK 33-41-00-040-001

Deactivation of the Glazing Panel of the Wing-Tip Navigation Light

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

R CAUTION : IF YOU DO A TEMPORARY REPAIR TO A CRACK, VISUALLY EXAMINE THE CRACK


_______
R EACH DAY, OR AT INTERVALS OF TEN FLIGHT CYCLES.
R IF, AFTER FIVE CHECKS, THE DIMENSION OF THE CRACK IS NOT LARGER,
R EXAMINE THE CRACK AT INTERVALS OF FIFTY FLIGHT CYCLES.

1. __________________
Reason for the Job

Refer to the CDL TASK: 33-6


Wing tip navigation light glazing

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific fine abrasive paper
No specific safety barriers
No specific soap solution
No specific warning notice
No specific access platform 4.35 m (14 ft. 3 in.)



EFF :

ALL  33-41-00

Page 401
May 01/02
 
IAC 
B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R No specific PR1829 Polysulphide Sealant for Glazings


Material No. 05-065 C Z-24.380
EROSION PROTECTIVE TAPE (Ref. 20-31-00)
R Material No. 09-045 GB DTD-900/6021
R SEALANT POLYSULPHIDE FOR WINDSHIELD (Ref. 20-31-00)
Material No. 19-003 USA AMS 3819
LINT-FREE COTTON CLOTH (Ref. 20-31-00)

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

57-37-12-000-001 Removal of the Navigation Light Glazing Panel


57-37-12-400-001 Installation of the Navigation Light Glazing Panel
33-41-00-991-003 Fig. 401

3. __________
Job Set-up

R (Ref. Fig. 401/TASK 33-41-00-991-003)

Subtask 33-41-00-941-050

A. Safety Precautions

(1) Put the safety barriers in position.

(2) Put a warning notice on panel 25VU to tell persons not to operate the
navigation lights or the strobe lights.

(3) Put the access platform below the applicable zone 534 (634).



EFF :

ALL  33-41-00

Page 402
Nov 01/00
 
IAC 
Subtask 33-41-00-865-052

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/EXT LT/NAV1/AND LOGO/LT 1LA T03
122VU LIGHTING/EXT LT/NAV2/AND LOGO/LT 2LA T02
122VU LIGHTING/WING/STROBE 10LV V05

4. Procedure
_________

(Ref. Fig. 401/TASK 33-41-00-991-003)

Subtask 33-41-00-040-050

A. Deactivation of the Wing-Tip Navigation Light Glazing Panel

(1) For a pre modification 25268 glazing panel:

(a) You must replace the glazing panel (Ref. TASK 57-37-12-000-001),
(Ref. TASK 57-37-12-400-001) if it has one of these conditions:
- a longitudinal crack of more than 153 mm (6.0236 in.) in length
- a vertical crack of more than 25.4 mm (1.0000 in.) in length
- broken glazing.

(b) If the glazing panel has a longitudinal crack of less than 153 mm
(6.0236 in.) or a vertical crack of less than 25.4 mm (1.0000
in.), do the repair that follows:

1
_ Drill a 6.4 mm (0.2519 in.) dia. hole at the end of the crack.

2
_ Use fine abrasive paper to make the repair area rough. The
repair area is 5.0 mm (0.1968 in.) more than and all around
the tape.

3
_ Clean the surface of the glazing panel with MISCELLANEOUS
(Material No. 19-003) made moist with warm soap solution.

4
_ Dry the surface of the glazing panel with a clean
MISCELLANEOUS (Material No. 19-003).

5
_ Apply SPECIAL MATERIALS (Material No. 05-065) to cover the
crack and the stop drilled hole.



EFF :

ALL  33-41-00

Page 403
Aug 01/06
 
IAC 
R Repair of the Wing-Tip Navigation Light Glazing Panel
Figure 401/TASK 33-41-00-991-003- 13 (SHEET 1)



EFF :

ALL  33-41-00

Page 404
Nov 01/05
 
IAC 
R Repair of the Wing-Tip Navigation Light Glazing Panel
Figure 401/TASK 33-41-00-991-003- 23 (SHEET 2)



EFF :

ALL  33-41-00

Page 405
Nov 01/05
 
IAC 
R Repair of the Wing-Tip Navigation Light Glazing Panel
Figure 401/TASK 33-41-00-991-003- 33 (SHEET 3)



EFF :

ALL  33-41-00

Page 406
Nov 01/05
 
IAC 
NOTE : Make sure that the tape is installed correctly and has
____
no bubbles, wrinkles or tears in it.

6
_ Let the tape cure for not less than 15 mins at a minimum
temperature of 15 deg.C (59.00 deg.F).

7
_ Make an entry in the aircraft technical log that the glazing
panel has a temporary repair.

CAUTION : IF YOU DO A TEMPORARY REPAIR TO A CRACK, VISUALLY


_______
EXAMINE THE CRACK EACH DAY, OR AT INTERVALS OF TEN
FLIGHT CYCLES.
IF, AFTER FIVE CHECKS, THE DIMENSION OF THE CRACK IS
NOT LARGER, EXAMINE THE CRACK AT INTERVALS OF FIFTY
FLIGHT CYCLES.

8
_ Examine the temporary repair(s) for an increase in the length
of the crack(s).

R (2) For a post modification 25268 (pre modification 28219) glazing panel:

(a) You must replace the glazing panel (Ref. TASK 57-37-12-000-001),
(Ref. TASK 57-37-12-400-001) if it has one of these conditions:
- a crack of more than 25 mm (0.9842 in.) in length
- more than 3 cracks from one bolt hole
- more than 2 cracks from one bolt hole are in the direction of
the panel edge
- more than 6 bolt holes have cracks
- more than 2 adjacent bolt holes have cracks
- the glazing is broken.

(b) If the glazing panel has a crack of more than 12.0 mm (0.4724
in.) and is less than 25 mm (0.9842 in.) in length, do the
temporary repair that follows:

NOTE : Cracks that are in the direction of the panel edge must
____
not be stop drilled.

1
_ Drill a 6.4 mm (0.2519 in.) dia. hole at the end of the crack.

2
_ Clean the surface of the glazing panel with MISCELLANEOUS
(Material No. 19-003) made moist with warm soap solution.

3
_ Dry the surface of the glazing panel with a clean
MISCELLANEOUS (Material No. 19-003).



EFF :

ALL  33-41-00

Page 407
Nov 01/05
 
IAC 
4
_ To make a weather seal, apply SEALANTS (Material No. 09-045)
or PR1829 Polysulphide Sealant for Glazings to cover the crack
and stop drilled hole.

5
_ Make an entry in the aircraft technical log that the glazing
panel has a temporary repair.

CAUTION : IF YOU DO A TEMPORARY REPAIR TO A CRACK, VISUALLY


_______
EXAMINE THE CRACK EACH DAY, OR AT INTERVALS OF TEN
FLIGHT CYCLES.
IF, AFTER FIVE CHECKS, THE DIMENSION OF THE CRACK IS
NOT LARGER, EXAMINE THE CRACK AT INTERVALS OF FIFTY
FLIGHT CYCLES.

6
_ Examine temporary repair(s) for an increase in the length of
the crack(s).

R (3) For a post modification 28219, 30791, 30889 or 32153 glazing panel:

(a) You must replace the glazing panel (Ref. TASK 57-37-12-000-001),
(Ref. TASK 57-37-12-400-001) if it has one of these conditions:
- more than one crack
- a vertical or longitudinal crack of more than 30 mm (1.1811
in.) in length
- a crack in the direction of the panel edge
- minimum thickness after polishing is less than 3.33 mm (0.1311
in.)
- broken glazing
- damage to the steel shield.

(b) If the glazing panel has a vertical or longitudinal crack of 30


mm (1.1811 in.) or less, do the repair that follows:

NOTE : A crack in the direction of the panel edge must not be


____
stop drilled.

1
_ Drill a 6.4 mm (0.2519 in.) dia. hole at the end of the crack.

2
_ Use fine abrasive paper to make the repair area rough. The
repair area is 5.0 mm (0.1968 in.) more than and all around
the tape.

3
_ Clean the surface of the glazing panel with MISCELLANEOUS
(Material No. 19-003) made moist with warm soap solution.

4
_ Dry the surface of the glazing panel with a clean
MISCELLANEOUS (Material No. 19-003).



EFF :

ALL  33-41-00

Page 408
Nov 01/05
 
IAC 
5
_ To make a weather seal, apply SEALANTS (Material No. 09-045)
or PR1829 Polysulphide Sealant for Glazings to cover the stop
drilled hole.

6
_ Apply SPECIAL MATERIALS (Material No. 05-065) to cover the
crack and the stop drilled hole.

NOTE : Make sure that the tape is installed correctly and has
____
no bubbles, wrinkles or tears in it.

7
_ Let the tape cure for not less than 15 mins at a minimum
temperature of 15 deg.C (59.00 deg.F).

8
_ Make an entry in the aircraft technical log that the glazing
panel has a temporary repair.

CAUTION : IF YOU DO A TEMPORARY REPAIR TO A CRACK, VISUALLY


_______
EXAMINE THE CRACK EACH DAY, OR AT INTERVALS OF TEN
FLIGHT CYCLES.
IF, AFTER FIVE CHECKS, THE DIMENSION OF THE CRACK IS
NOT LARGER, EXAMINE THE CRACK AT INTERVALS OF FIFTY
FLIGHT CYCLES.

9
_ Examine the temporary repair for an increase in the length of
the crack.

5. Close-up
________

Subtask 33-41-00-865-053

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LA, 2LA, 10LV.

Subtask 33-41-00-942-050

B. Removal of Equipment

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the safety barriers.

(3) Remove the warning notice(s).

(4) Remove the access platform(s).

(5) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.



EFF :

ALL  33-41-00

Page 409
Nov 01/05
R  
IAC 
TASK 33-41-00-440-001

Reactivation of the Glazing Panel of the Wing-Tip Navigation Light

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

1. __________________
Reason for the Job

Refer to the CDL TASK: 33-6


Wing tip navigation light glazing

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific safety barriers
No specific warning notice
No specific access platform 4.35 m (14 ft. 3 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

57-37-12-000-001 Removal of the Navigation Light Glazing Panel


57-37-12-400-001 Installation of the Navigation Light Glazing Panel


R

EFF :

ALL  33-41-00

Page 410
May 01/06
 
IAC 
3. __________
Job Set-up

Subtask 33-41-00-941-051

A. Safety Precautions

(1) Put the safety barriers in position.

(2) Put a warning notice on panel 25VU to tell persons not to operate the
navigation lights or the strobe lights.

(3) Put the access platform below the applicable zone 534 (634).

Subtask 33-41-00-865-054

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/EXT LT/NAV1/AND LOGO/LT 1LA T03
122VU LIGHTING/EXT LT/NAV2/AND LOGO/LT 2LA T02
122VU LIGHTING/WING/STROBE 10LV V05

4. Procedure
_________

Subtask 33-41-00-440-050

A. Reactivation of the Glazing Panel of the Wing-Tip Navigation Light

(1) Replace the wing-tip navigation light glazing panel (Ref. TASK 57-37-
12-000-001), (Ref. TASK 57-37-12-400-001).

5. Close-up
________

Subtask 33-41-00-865-055

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LA, 2LA, 10LV.



EFF :

ALL  33-41-00

Page 411
Aug 01/06
 
IAC 
INTENTIONALLY BLANK


R



 33-41-00

Page 412
May 01/06
 
IAC 
Subtask 33-41-00-942-051

B. Removal of Equipment

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the safaty barriers.

(3) Remove the warning notice(s).

(4) Remove the access platform(s).

(5) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.

(6) Write in the aircraft technical log that the glazing panel of the
wing-tip navigation light has been replaced.



EFF :

ALL  33-41-00

Page 413
May 01/01
R  
IAC 
TASK 33-41-00-040-002

Deactivation of the Lens of the Tail Navigation Light

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

1. __________________
Reason for the Job

Refer to the CDL TASK: 33-3


Rear navigation light lens (glazing)

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific safety barriers
No specific warning notice
No specific access platform 4.5 m (14 ft. 9 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-41-15-000-001 Removal of the Tail Navigation Light 15LA



EFF :

ALL  33-41-00

Page 414
May 01/01
R  
IAC 
3. __________
Job Set-up

Subtask 33-41-00-941-054

A. Safety Precautions

WARNING : DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT


_______
BURNS WHEN YOU DO THE MAINTENANCE TASK(S).

(1) Put the safety barriers in position.

(2) Put a warning notice in the cockpit to tell persons not to operate
the tail navigation light.

(3) Put a warning notice in position to tell persons not to operate the
APU.

Subtask 33-41-00-941-052

B. Get Access

(1) Put the access platform at the APU tail-cone exhaust area Zone 317.

Subtask 33-41-00-865-056

C. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
121VU APU/APU/CTL 2KD L42
121VU APU/ECB/SPLY 1KD L41
122VU LIGHTING/EXT LT/NAV1/AND LOGO/LT 1LA T03
122VU LIGHTING/EXT LT/NAV2/AND LOGO/LT 2LA T02



EFF :

ALL  33-41-00

Page 415
Aug 01/06
 
IAC 
R

4. Procedure
_________

Subtask 33-41-00-040-051

A. Deactivation of the Lens of the Tail Navigation Light

(1) Remove the lens only (Ref. TASK 33-41-15-000-001).

(2) Write a note in the aircraft technical log that the lens has been
deactivated.

5. Close-up
________

Subtask 33-41-00-865-057

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
2KD, 1KD, 1LA, 2LA.

Subtask 33-41-00-942-052

B. Removal of Equipment

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the safety barriers.

(3) Remove the warning notice(s).

(4) Remove the access platform(s).

(5) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.



EFF :

ALL  33-41-00

Page 416
Aug 01/06
 
IAC 
TASK 33-41-00-440-002

Reactivation of the Lens of the Tail Navigation Light

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

1. __________________
Reason for the Job

Refer to the CDL TASK: 33-3


Rear navigation light lens (glazing)

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific safety barriers
No specific warning notice
No specific access platform 4.5 m (14 ft. 9 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-41-15-400-001 Installation of the Tail Navigation Light 15LA

3. __________
Job Set-up

Subtask 33-41-00-941-055

A. Safety Precautions

WARNING : DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT


_______
BURNS WHEN YOU DO THE MAINTENANCE TASK(S).

(1) Put the safety barriers in position.



EFF :

ALL  33-41-00

Page 417
May 01/06
R  
IAC 
(2) Put a warning notice in the cockpit to tell persons not to operate
the tail navigation light.

(3) Put a warning notice in position to tell persons not to operate the
APU.

Subtask 33-41-00-941-053

B. Get Access

(1) Put the access platform in position at the APU tail-cone exhaust area
Zone 317.

Subtask 33-41-00-865-058

C. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
121VU APU/APU/CTL 2KD L42
121VU APU/ECB/SPLY 1KD L41
122VU LIGHTING/EXT LT/NAV1/AND LOGO/LT 1LA T03
122VU LIGHTING/EXT LT/NAV2/AND LOGO/LT 2LA T02

4. Procedure
_________

Subtask 33-41-00-440-051

A. Reactivation of the Lens of the Tail Navigation Light

(1) Install a new lens only (Ref. TASK 33-41-15-400-001).

(2) Write a note in the aircraft technical log that the lens of the tail
navigation light has been reactivated.



EFF :

ALL  33-41-00

Page 418
Aug 01/06
 
IAC 
5. Close-up
________

Subtask 33-41-00-865-059

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
2KD, 1KD, 1LA, 2LA.

Subtask 33-41-00-942-053

B. Removal of Equipment

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the safety barriers.

(3) Remove the warning notice(s).

(4) Remove the access platform(s).

(5) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.



EFF :

ALL  33-41-00

Page 419
May 01/01
 
IAC 
NAVIGATION LIGHTS - ADJUSTMENT/TEST
___________________________________

TASK 33-41-00-710-001

Operational Test of the Navigation Lights

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

1. __________________
Reason for the Job

R
R Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific safety barriers


No specific warning notice

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
33-41-00-991-001 Fig. 501



EFF :

ALL  33-41-00

Page 501
May 01/05
 
IAC 
3. __________
Job Set-up

Subtask 33-41-00-941-056

A. Safety Precautions

(1) Put the safety barriers in position.

(2) Put a warning notice on the panel 25VU to tell persons not to operate
the navigation lights or the strobe lights.

Subtask 33-41-00-861-050

B. Energize the Electrical Circuits

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

4. Procedure
_________

(Ref. Fig. 501/TASK 33-41-00-991-001)

Subtask 33-41-00-710-050-A

A. Operational Test

(1) Operational Test of the Navigation Lights

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the EXT LT control panel 25VU: - the NAV 1 lamps of the navigation
- put the toggle switch NAV & LOGO lights (9LA and 10LA) come on
(3LA) to the 1 position - the NAV 1 lamp of the navigation
light (15LA) comes on

- put the toggle switch NAV & LOGO - the NAV 2 lamps of the navigation
(3LA) to the 2 position lights (9LA and 10LA) come on and the
NAV 1 lamps go off
- the NAV 2 lamp of the navigation
light (15LA) comes on and the NAV 1
lamp goes off

- put the toggle switch NAV & LOGO - the navigation lights (9LA, 10LA and
(3LA) to the OFF position. 15LA) go off.



EFF :

ALL  33-41-00

Page 502
May 01/05
R  
IAC 
Navigation Lights - Component Location
Figure 501/TASK 33-41-00-991-001



EFF :

ALL  33-41-00

Page 503
Feb 01/96
 
IAC 
5. Close-up
________

Subtask 33-41-00-862-050

A. De-energize the Electrical Circuits

(1) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).

Subtask 33-41-00-942-054

B. Removal of Equipment

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the safety barriers.

(3) Remove the warning notice(s).

(4) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.



EFF :

ALL  33-41-00

Page 504
Feb 01/96
 
IAC 
LIGHT - NAVIGATION (9LA,10LA) - REMOVAL/INSTALLATION
____________________________________________________

TASK 33-41-11-000-001

R Removal of the Wingtip Navigation Light 9LA(10LA)

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific safety barriers
No specific warning notice
No specific access platform 4.0 m (13 ft. 1 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

57-37-12-000-001 Removal of the Navigation Light Glazing Panel


33-41-11-991-001 Fig. 401



EFF :

ALL  33-41-11

Page 401
Nov 01/98
 
IAC 
3. __________
Job Set-up

Subtask 33-41-11-941-052

A. Safety Precautions

(1) Put the safety barriers in position.

(2) Put a warning notice in position on panel 25VU to tell persons not to
operate the strobe lights or the navigation lights.

Subtask 33-41-11-865-050

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/EXT LT/NAV1/AND LOGO/LT 1LA T03
122VU LIGHTING/EXT LT/NAV2/AND LOGO/LT 2LA T02
122VU LIGHTING/WING/STROBE 10LV V05

Subtask 33-41-11-010-052

C. Get Access

(1) Put the access platform below applicable zone 534 or 634.

(2) Remove the wingtip glazing panel (1) (Ref. TASK 57-37-12-000-001).

4. Procedure
_________

(Ref. Fig. 401/TASK 33-41-11-991-001)

Subtask 33-41-11-020-050

A. Removal of the Wingtip Navigation Light

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.

(1) Remove the bolts (5) and the washers (4).



EFF :

ALL  33-41-11

Page 402
Aug 01/06
 
IAC 
Wingtip Navigation Light
Figure 401/TASK 33-41-11-991-001



EFF :

ALL  33-41-11

Page 403
Feb 01/96
 
IAC 
(2) Pull out the navigation light (3) sufficiently and disconnect the
electrical connector (2).

(3) Remove the navigation light (3).

(4) Put blanking caps on the disconnected electrical connectors.



EFF :

ALL  33-41-11

Page 404
Feb 01/96
 
IAC 
TASK 33-41-11-400-001

Installation of the Wingtip Navigation Light 9LA(10LA)

WARNING : MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING
_______
NOTICES ARE IN POSITION.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific safety barriers


No specific warning notice
No specific access platform 4 m (13 ft. 1 in.)

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 11-004 USA MIL-T-81533


1.1.1TRICHLOROETHANE (METHYL CHLOROFORM)
(Ref. 20-31-00)
R Material No. 15-008 AIB TN 10138 TYPE II GRADE 2
R CORROSION PREVENTIVE TEMPORARY PROTECTIVE COMPOUND
R (Ref. 20-31-00)
Material No. 19-003 USA AMS 3819
LINT-FREE COTTON CLOTH (Ref. 20-31-00)



EFF :

ALL  33-41-11

Page 405
May 01/06
 
IAC 
C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

20-28-00-912-004 Electrical Bonding of Components With Conductive


Bolts and Screws and Bonding Straps in the Fuselage
R and in the Wings (this does not include the tanks)-
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
33-41-00-710-001 Operational Test of the Navigation Lights
57-37-12-000-001 Removal of the Navigation Light Glazing Panel
57-37-12-400-001 Installation of the Navigation Light Glazing Panel
33-41-11-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-41-11-941-053

A. Safety Precautions

(1) Make sure that the safety barriers are in position.

(2) Make sure that the warning notice is on the panel 25VU to tell
persons not to operate the strobe lights or the navigation lights.

Subtask 33-41-11-860-050

B. Aircraft Maintenance Configuration

(1) Make sure that the access platform is in position below the
applicable zone 534 or 634.

(2) Make sure that the navigation light glazing panel (1) has been
removed (Ref. TASK 57-37-12-000-001).



EFF :

ALL  33-41-11

Page 406
May 01/06
 
IAC 
4. Procedure
_________

(Ref. Fig. 401/TASK 33-41-11-991-001)

Subtask 33-41-11-420-053

A. Preparation for Installation

WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL


_______
MATERIALS ONLY WITH A GOOD SUPPLY OF AIR.
OBEY THE MANUFACTURERS INSTRUCTIONS.
PUT ON PROTECTIVE CLOTHING.
DO NOT GET THEM IN YOUR MOUTH.
DO NOT SMOKE.
DO NOT BREATHE THE GAS.
THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT.
GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.

(1) Clean the component interface and/or the adjacent area with a clean
MISCELLANEOUS (Material No. 19-003) made moist with CLEANING AGENTS
(Material No. 11-004).

(2) Make sure that the parts retained from the removed component are
clean and in the correct condition.

(3) Do an inspection of the component interface and/or the adjacent area.

(4) Make sure the electrical connector is in the correct condition.

R **ON A/C 001-012, 014-099,

Subtask 33-41-11-420-052

B. Installation of the Wingtip Navigation Light

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.

(1) Remove the blanking cap from the electrical connector (2).

(2) Put the navigation light (3) in position and connect the electrical
connector (2).



EFF :

ALL  33-41-11

Page 407
May 01/06
 
IAC 
(3) Install the navigation light (3) with the washers (4) and the bolts
(5) (Ref. TASK 20-28-00-912-004).

R **ON A/C 101-199, 901-999,

Subtask 33-41-11-420-052-A

B. Installation of the Wingtip Navigation Light

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.

(1) Remove the blanking cap from the electrical connector (2).

(2) Put the navigation light (3) in position and connect the electrical
connector (2).

(3) Clean the electrical connector (2) with a MISCELLANEOUS (Material No.
19-003) made moist with CLEANING AGENTS (Material No. 11-004).

(4) Apply a continuous layer of STORAGE PRESERVATION (Material No. 15-


008) to the electrical connector (2).

(5) Install the navigation light (3) with the washers (4) and the bolts
(5) (Ref. TASK 20-28-00-912-004).

**ON A/C ALL

Subtask 33-41-11-861-050

C. Aircraft Maintenance Configuration

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

Subtask 33-41-11-865-051

D. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LA, 2LA.



EFF :

ALL  33-41-11

Page 408
Feb 01/07
 
IAC 
Subtask 33-41-11-710-050

E. Test

(1) Do an operational test of the navigation lights (Ref. TASK 33-41-00-


710-001).

5. Close-up
________

Subtask 33-41-11-862-050

A. Aircraft Maintenance Configuration

(1) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).

Subtask 33-41-11-410-050

B. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the wingtip glazing panel (1) (Ref. TASK 57-37-12-400-001).

Subtask 33-41-11-942-050

C. Removal of Equipment

(1) Remove the safety barriers.

(2) Remove the warning notice(s).

(3) Remove the access platform(s).

(4) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.



EFF :

ALL  33-41-11

Page 409
May 01/06
R  
IAC 
TASK 33-41-11-000-002

Removal of the Lamp in the Wingtip Navigation Light

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific lint-free cloth
R No specific AR ACCESS PLATFORM 4M (13 FT)
R No specific AR SAFETY BARRIER
R No specific AR WARNING NOTICE

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

57-37-12-000-001 Removal of the Navigation Light Glazing Panel


33-41-11-991-002 Fig. 402



EFF :

ALL  33-41-11

Page 410
Aug 01/07
 
IAC 
3. __________
Job Set-up

(Ref. Fig. 402/TASK 33-41-11-991-002)

Subtask 33-41-11-941-051

A. Safety Precautions

R (1) Put the SAFETY BARRIERS in position.

R (2) Put a WARNING NOTICE in position on the panel 25VU to tell persons
R not to operate:
R - the strobe lights
R - the navigation lights.
R

Subtask 33-41-11-865-055

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/NAV1/AND LOGO/LT 1LA T03
122VU LIGHTING/EXT LT/NAV2/AND LOGO/LT 2LA T02
122VU LIGHTING/WING/STROBE 10LV V05

Subtask 33-41-11-010-053

C. Get Access

R (1) Put the ACCESS PLATFORM 4M (13 FT) below applicable zone 534 or 634.

(2) Remove the wingtip glazing panel (Ref. TASK 57-37-12-000-001).

4. Procedure
_________

Subtask 33-41-11-020-051-A

A. Removal of the Wingtip Navigation-Light Lamp

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.



EFF :

ALL  33-41-11

Page 411
Aug 01/07
 
IAC 
R Wingtip Navigation Light Lamp - Location and Details
R Figure 402/TASK 33-41-11-991-002



EFF :

ALL  33-41-11

Page 412
Aug 01/06
 
IAC 
CAUTION : DO NOT USE NON APPROVED METAL TOOLS TO REMOVE THE LAMP FROM THE
_______
LAMP HOLDER. THESE METAL TOOLS CAN CAUSE DAMAGE TO THE LAMP
REFLECTOR AND THE LAMP HOLDER.

CAUTION : DO NOT APPLY TOO MUCH FORCE TO THE BULB OR SOCKET CONTACTS. TOO
_______
MUCH FORCE CAN CAUSE PERMANENT DEFORMATION OF THE SOCKET, AND
AS A RESULT, ARCING AND THUS BULB FAILURE.

NOTE : This procedure is applicable to one and two-lamp wingtip


____
navigation lights.

R (1) Release the clips (4) that hold the glass (3) of the navigation light
R in position.

R (2) Remove the glass (3) and the gasket (2).

R (3) Use a lint-free cloth to carefully remove the lamp (1) from the
R navigation light as follows:

R (a) Carefully push the lamp (1) vertically up (or down) to release
R the lower (or higher) location spigot.

R (b) Carefully pull and remove the lamp (1) from the lamp socket.

R NOTE : To remove the lamp (1) without damage, put a piece of


____
R string or cable tie around the lamp (1). The string/cable
R tie can then be used to safely pull the lamp (1) out of
R position.



EFF :

ALL  33-41-11

Page 413
Aug 01/06
 
IAC 
TASK 33-41-11-400-002

Installation of the Lamp in the Wingtip Navigation Light

WARNING : MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING
_______
NOTICES ARE IN POSITION.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific lint-free cloth


R No specific AR ACCESS PLATFORM 4M (13 FT)
R No specific AR SAFETY BARRIER
R No specific AR WARNING NOTICE

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 11-026 GB DEF-STAN 68-148/1


SOLVENT GENERAL PURPOSE (Ref. 20-31-00)
Material No. 19-003 USA AMS 3819
LINT-FREE COTTON CLOTH (Ref. 20-31-00)

C. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

2 gasket 33-41-11 01E-035



EFF :

ALL  33-41-11

Page 414
Aug 01/07
 
IAC 
D. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
33-41-00-710-001 Operational Test of the Navigation Lights
57-37-12-000-001 Removal of the Navigation Light Glazing Panel
57-37-12-400-001 Installation of the Navigation Light Glazing Panel
33-41-11-991-002 Fig. 402

3. __________
Job Set-up

(Ref. Fig. 402/TASK 33-41-11-991-002)

Subtask 33-41-11-941-054

A. Safety Precautions

R (1) Make sure that the SAFETY BARRIERS are in position.

R (2) Make sure that the WARNING NOTICE is on the panel 25VU to tell
R persons not to operate:
R - the strobe lights
R - the navigation lights.
R

Subtask 33-41-11-860-052

B. Aircraft Maintenance Configuration

R (1) Make sure that the ACCESS PLATFORM 4M (13 FT) is in position below
the applicable zone 534 or 634.

(2) Make sure that the navigation light glazing panel is removed
(Ref. TASK 57-37-12-000-001).



EFF :

ALL  33-41-11

Page 415
Aug 01/07
 
IAC 
4. Procedure
_________

Subtask 33-41-11-420-054

A. Preparation for Installation

(1) Clean the component interface and/or the adjacent area with a clean
MISCELLANEOUS (Material No. 19-003) made moist with CLEANING AGENTS
(Material No. 11-026).

(2) Make sure that the lamp (1) and the glass (3) are clean and in the
correct condition.

(3) Make sure that the gasket (2) is not damaged. If necessary, replace
the gasket (2).

(4) Do an inspection of the component interface and/or the adjacent area.

Subtask 33-41-11-420-051-A

B. Installation of the Lamp in the Wingtip Navigation-Light

CAUTION : USE ONLY APPROVED LAMPS. LAMPS THAT ARE NOT APPROVED CAN CAUSE
_______
DAMAGE TO THE NAVIGATION-LIGHT TRANSFORMER AND LAMP-HOLDER.

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.

CAUTION : DO NOT APPLY TOO MUCH FORCE TO THE BULB OR SOCKET CONTACTS. TOO
_______
MUCH FORCE CAN CAUSE PERMANENT DEFORMATION OF THE SOCKET, AND
AS A RESULT, ARCING AND THUS BULB FAILURE.

NOTE : This procedure is applicable for one and two-lamp wingtip


____
navigation lights.

(1) Use a lint-free cloth to hold the lamp (1).

(2) Put the base of the lamp (1) into the lamp socket. Carefully push the
lamp (1) and make sure that the two locating spigots engage the slots
of the contact strip.

(3) Put the gasket (2) and the glass (3) in position on the navigation
light and install the two clips (4).



EFF :

ALL  33-41-11

Page 416
Aug 01/07
R  
IAC 
Subtask 33-41-11-861-051

C. Aircraft Maintenance Configuration

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

Subtask 33-41-11-865-056

R D. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
R 1LA, 2LA, 10LV.

Subtask 33-41-11-710-051

E. Test

(1) Do an operational test of the navigation lights (Ref. TASK 33-41-00-


710-001).

5. Close-up
________

Subtask 33-41-11-862-051

A. Aircraft Maintenance Configuration

(1) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).

Subtask 33-41-11-410-051

B. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the wingtip glazing panel (Ref. TASK 57-37-12-400-001).

Subtask 33-41-11-942-051

C. Removal of Equipment

(1) Remove the safety barriers.

(2) Remove the warning notice(s).

(3) Remove the access platform(s).



EFF :

ALL  33-41-11

Page 417
Aug 01/07
 
IAC 
(4) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.



EFF :

ALL  33-41-11

Page 418
Aug 01/06
 
IAC 
LIGHT - NAVIGATION, TAIL (15LA) - REMOVAL/INSTALLATION
______________________________________________________

TASK 33-41-15-000-001

Removal of the Tail Navigation Light 15LA

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific 1 ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-41-15-991-001-A Fig. 401

3. __________
Job Set-up

Subtask 33-41-15-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
121VU APU/APU/CTL 2KD L42
121VU APU/ECB/SPLY 1KD L41
122VU LIGHTING/EXT LT/NAV1/AND LOGO/LT 1LA T03
122VU LIGHTING/EXT LT/NAV2/AND LOGO/LT 2LA T02
122VU LIGHTING/WING/STROBE 10LV V05



EFF :

ALL  33-41-15

Page 401
Aug 01/06
 
IAC 
R

Subtask 33-41-15-941-050

B. Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the APU
tail-cone-exhaust area, Zone 317.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-41-15-991-001-A)

Subtask 33-41-15-020-051-A

A. Removal of the tail navigation light

WARNING : DO NOT REMOVE THE STROBE LIGHT FOR AT LEAST TEN MINUTES AFTER
_______
YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS. THE HIGH VOLTAGE
ELECTRICAL CURRENT IN THE CAPACITOR OF THE STROBE LIGHT IS
DANGEROUS.

(1) Hold the tail navigation light (3).

(2) Remove the screws (1) and the washers (2).

(3) Remove the tail navigation light (3) from the APU exhaust
access-fairing (4) sufficiently to get access to the electrical
connectors (5) and (6).

(4) Disconnect the electrical connectors (5) and (6) from the tail
navigation light (3).

(5) Put blanking caps on the disconnected electrical connectors.



EFF :

ALL  33-41-15

Page 402
Aug 01/06
 
IAC 
R Tail Navigation Light 15LA
R Figure 401/TASK 33-41-15-991-001-A



EFF :

ALL  33-41-15

Page 403
Nov 01/04
 
IAC 
TASK 33-41-15-400-001

Installation of the Tail Navigation Light 15LA

WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL MATERIALS


_______
ONLY WITH A GOOD SUPPLY OF AIR.
OBEY THE MANUFACTURERS INSTRUCTIONS.
PUT ON PROTECTIVE CLOTHING.
DO NOT GET THEM IN YOUR MOUTH.
DO NOT SMOKE.
DO NOT BREATHE THE GAS.
THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT.
GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R
Material No. 09-019 USA AMS 3267/3
LOW ADHESION CORROSION INHIBITING SEALANT
(Ref. 20-31-00)
Material No. 09-023 USA MIL-S-38249 TYPE I
FIRE WALL SEALANT (Ref. 20-31-00)
Material No. 19-003 USA AMS 3819
LINT-FREE COTTON CLOTH (Ref. 20-31-00)



EFF :

ALL  33-41-15

Page 404
May 01/05
 
IAC 
B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
33-41-00-710-001 Operational Test of the Navigation Lights
33-48-00-710-002 Operational Test of the Anti-Collision/Strobe
Lighting
33-41-15-991-001-A Fig. 401

3. __________
Job Set-up

Subtask 33-41-15-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
121VU APU/APU/CTL 2KD L42
121VU APU/ECB/SPLY 1KD L41
122VU LIGHTING/EXT LT/NAV1/AND LOGO/LT 1LA T03
122VU LIGHTING/EXT LT/NAV2/AND LOGO/LT 2LA T02
122VU LIGHTING/WING/STROBE 10LV V05

4. Procedure
_________

(Ref. Fig. 401/TASK 33-41-15-991-001-A)

Subtask 33-41-15-910-050

A. Preparation for Installation

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.



EFF :

ALL  33-41-15

Page 405
Aug 01/06
 
IAC 
Subtask 33-41-15-420-051-A

B. Installation of the Tail Navigation Light

(1) Remove the blanking caps from the electrical connectors (5) and (6).

(2) Make sure that the electrical connectors are clean and in the correct
condition.

(3) Connect the electrical connectors (5) and (6) to the tail navigation
light (3).

(4) Put the tail navigation light (3) in position on the APU exhaust
access-fairing (4).

(5) Install the the screws (1) and the washers (2).

(6) Clean the outer side of the tail navigation light (3) with a,
MISCELLANEOUS (Material No. 19-003).

(7) Apply the SEALANTS (Material No. 09-023), or the SEALANTS (Material
No. 09-019) to all sides of the mating flange of the tail navigation
light (3), the washers (2) and the screws (1).

NOTE : The tack free


____ time of the SEALANTS (Material No. 09-023) is 24
hours and the cure time is 72 hours at 25 deg.C (77.00 deg.F).
The tack free time of the SEALANTS (Material No. 09-019) is 10
hours and the cure time is 24 hours at 25 deg.C (77.00 deg.F).

Subtask 33-41-15-865-052

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LA, 2LA, 10LV, 1KD, 2KD.

Subtask 33-41-15-861-050

D. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-41-15-710-050

E. Do the operational test of the tail navigation lights (Ref. TASK 33-41-
00-710-001) and (Ref. TASK 33-48-00-710-002).



EFF :

ALL  33-41-15

Page 406
Aug 01/06
R  
IAC 
5. Close-up
________

Subtask 33-41-15-942-050

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the access platform(s).

Subtask 33-41-15-862-050

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-41-15

Page 407
Aug 01/06
R  
IAC 
TASK 33-41-15-000-002

Removal of the Lamp(s) of the Tail Navigation Light 15LA

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific 1 ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-41-15-991-002 Fig. 402

3. __________
Job Set-up

Subtask 33-41-15-865-053

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
121VU APU/APU/CTL 2KD L42
121VU APU/ECB/SPLY 1KD L41
122VU LIGHTING/EXT LT/NAV1/AND LOGO/LT 1LA T03
122VU LIGHTING/EXT LT/NAV2/AND LOGO/LT 2LA T02
122VU LIGHTING/WING/STROBE 10LV V05



EFF :

ALL  33-41-15

Page 408
Aug 01/06
 
IAC 
R

Subtask 33-41-15-941-051

B. Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the APU
tail-cone-exhaust area, Zone 317.

4. Procedure
_________

(Ref. Fig. 402/TASK 33-41-15-991-002)

Subtask 33-41-15-020-052

A. Removal of the Lamps of the Tail Navigation Light

(1) Only if a sealing is defective, discard it.

(2) Hold the lens (7).

(3) Remove the screws (9).

(4) Remove and discard the sealing-rings (8).

(5) Remove the lens (7) from the tail navigation light (1).

(6) Remove the sealing (4).

(7) Remove the clips (6) and (10) and the white lenses (5) and (11).

(8) Remove the lamps (3) and (12).

(9) Remove the sealing (2) and (13).



EFF :

ALL  33-41-15

Page 409
Aug 01/06
 
IAC 
R Tail Navigation Light 15LA
R Figure 402/TASK 33-41-15-991-002



EFF :

ALL  33-41-15

Page 410
Nov 01/04
 
IAC 
TASK 33-41-15-400-002

Installation of the Lamp(s) of the Tail Navigation Light 15LA

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

R 8 sealing-ring 33-41-15 01 -030


8 sealing-ring 33-41-15 01A-030

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
33-41-00-710-001 Operational Test of the Navigation Lights
33-48-00-710-002 Operational Test of the Anti-Collision/Strobe
Lighting
33-41-15-991-002 Fig. 402



EFF :

ALL  33-41-15

Page 411
May 01/08
 
IAC 
3. __________
Job Set-up

Subtask 33-41-15-865-054

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
121VU APU/APU/CTL 2KD L42
121VU APU/ECB/SPLY 1KD L41
122VU LIGHTING/EXT LT/NAV1/AND LOGO/LT 1LA T03
122VU LIGHTING/EXT LT/NAV2/AND LOGO/LT 2LA T02
122VU LIGHTING/WING/STROBE 10LV V05

4. Procedure
_________

(Ref. Fig. 402/TASK 33-41-15-991-002)

Subtask 33-41-15-910-051

A. Preparation for Installation

(1) Make sure that the parts retained from the removed component are
clean and in the correct condition.

(2) Clean the component interface and/or the adjacent area.

(3) Do an inspection of the component interface and/or the adjacent area.

Subtask 33-41-15-420-052

B. Installation of the Lamps of the Tail Navigation Light

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.

(1) Only install new sealings, if necessary.

(2) Install the sealings (2) and (13).

(3) Install the lamps (3) and (12).



EFF :

ALL  33-41-15

Page 412
May 01/08
R  
IAC 
R (4) Put the white lenses (5) and (11) in position on the tail navigation
light (1) and install the clips (6) and (10).

R (5) Install the sealing (4).

R (6) Put the lens (7) in position on the tail navigation light (1).

R (7) Install the screws (9) each with a new sealing-ring (8).

Subtask 33-41-15-865-055

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LA, 2LA, 10LV, 1KD, 2KD.

Subtask 33-41-15-861-051

D. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-41-15-710-051

R E. Do the operational test of the tail navigation lights (Ref. TASK 33-41-
R 00-710-001) and (Ref. TASK 33-48-00-710-002).

5. Close-up
________

Subtask 33-41-15-942-051

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the access platform(s).

Subtask 33-41-15-862-051

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-41-15

Page 413
May 01/05
 
IAC 
TRANSFORMER - TAIL NAVIGATION LIGHT (13LA) - REMOVAL/INSTALLATION
_________________________________________________________________

TASK 33-41-16-000-001

Removal of the Tail Navigation-Light Transformer 13LA

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific access platform 4.0 m (13 ft. 1 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R 33-41-15-000-001 Removal of the Tail Navigation Light 15LA


52-41-18-000-001 Removal of the APU Exhaust Access-Fairing 317AL
33-41-16-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-41-16-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
121VU APU/APU/CTL 2KD L42
121VU APU/ECB/SPLY 1KD L41
122VU LIGHTING/EXT LT/NAV1/AND LOGO/LT 1LA T03
122VU LIGHTING/EXT LT/NAV2/AND LOGO/LT 2LA T02
122VU LIGHTING/WING/STROBE 10LV V05



EFF :

ALL  33-41-16

Page 401
Aug 01/07
 
IAC 
Subtask 33-41-16-010-050

B. Get Access

R (1) Put the access platform in the APU tail-cone exhaust area Zone 317.

R (2) Remove the APU exhaust access fairing 317AL (Ref. TASK 52-41-18-000-
R 001) or, as an alternative, the tail navigation light 15LA (Ref. TASK
R 33-41-15-000-001).

4. Procedure
_________

(Ref. Fig. 401/TASK 33-41-16-991-001)

Subtask 33-41-16-020-051

A. Removal of the Tail Navigation-Light Transformer 13LA

R (1) Disconnect the electrical connectors (1) and (6).

(2) Put blanking caps on the disconnected electrical connectors.

R (3) Remove the screws (2) and the washers (3).

R (4) Remove the screw (4) and the washer (5).

R (5) Remove the transformer plate (7) with the transformer from the APU
R exhaust access fairing.



EFF :

ALL  33-41-16

Page 402
Aug 01/07
 
IAC 
R Tail Navigation-Light Transformer 13LA
Figure 401/TASK 33-41-16-991-001



EFF :

ALL  33-41-16

Page 403
Aug 01/07
 
IAC 
TASK 33-41-16-400-001

Installation of the Tail Navigation-Light Transformer 13LA

WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL MATERIALS


_______
ONLY WITH A GOOD SUPPLY OF AIR.
OBEY THE MANUFACTURERS INSTRUCTIONS.
PUT ON PROTECTIVE CLOTHING.
DO NOT GET THEM IN YOUR MOUTH.
DO NOT SMOKE.
DO NOT BREATHE THE GAS.
THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT.
GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R Material No. 05-002 USA MIL-PRF-8116


PUTTY, ZINC CHROMATE GENERAL PURPOSE (Ref. 20-31-00)
Material No. 09-003 C Z-16.115
SEALANT,POLYSULFIDE (USE 09-018) (Ref. 20-31-00)
Material No. 09-023 USA MIL-S-38249 TYPE I
FIRE WALL SEALANT (Ref. 20-31-00)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

20-28-00-912-004 Electrical Bonding of Components With Conductive


Bolts and Screws and Bonding Straps in the Fuselage
and in the Wings (this does not include the tanks)-
33-41-00-710-001 Operational Test of the Navigation Lights
33-41-15-400-001 Installation of the Tail Navigation Light 15LA
33-48-00-710-002 Operational Test of the Anti-Collision/Strobe
Lighting
52-41-18-400-001 Installation of the APU Exhaust Access-Fairing 317AL



EFF :

ALL  33-41-16

Page 404
Feb 01/08
 
IAC 
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-41-16-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-41-16-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
121VU APU/APU/CTL 2KD L42
121VU APU/ECB/SPLY 1KD L41
122VU LIGHTING/EXT LT/NAV1/AND LOGO/LT 1LA T03
122VU LIGHTING/EXT LT/NAV2/AND LOGO/LT 2LA T02
122VU LIGHTING/WING/STROBE 10LV V05

4. Procedure
_________

(Ref. Fig. 401/TASK 33-41-16-991-001)

R WARNING : OBEY THE MANUFACTURERS INSTRUCTIONS WHEN YOU USE THE SPECIAL
_______
R MATERIAL.
R THIS MATERIAL IS DANGEROUS.

Subtask 33-41-16-910-050

A. Preparation for Installation

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

R WARNING : THE SEALANT IS CLASSIFIED AS A DANGEROUS MATERIAL WHICH CAN


_______
R CAUSE INJURY OR ILLNESS IF IT IS NOT CORRECTLY USED. BEFORE
R YOU USE THIS PRODUCT, READ THE APPLICABLE MANUFACTURERS
R MATERIAL DATA SAFETY SHEET AND OBEY THE SAFETY AND HEALTH
R PRECAUTIONS.

(3) Apply the SEALANTS (Material No. 09-003) to the mating surfaces.



EFF :

ALL  33-41-16

Page 405
Aug 01/07
 
IAC 
R (4) Apply the putty, SPECIAL MATERIALS (Material No. 05-002) to the
R screws (2) and (4) and the washers (3) and (5).

Subtask 33-41-16-420-050

B. Installation of the Tail Navigation-Light Transformer 13LA

R (1) Install the transformer plate (7) with the transformer in the APU
R exhaust access fairing.

R (2) Install the screw (4) and the washer (5) for bonding (Ref. TASK 20-
R 28-00-912-004).

R (3) Install the screws (2) and the washers (3).

R WARNING : THE SEALANT IS CLASSIFIED AS A DANGEROUS MATERIAL WHICH CAN


_______
R CAUSE INJURY OR ILLNESS IF IT IS NOT CORRECTLY USED. BEFORE
R YOU USE THIS PRODUCT, READ THE APPLICABLE MANUFACTURERS
R MATERIAL DATA SAFETY SHEET AND OBEY THE SAFETY AND HEALTH
R PRECAUTIONS.

R (4) Seal the screws (2) and (4) and the washers (3) and (5) with the
R SEALANTS (Material No. 09-023).

R (5) Remove the blanking caps from the electrical connectors.

R (6) Connect the electrical connectors (1) and (6).

Subtask 33-41-16-410-050

R C. Install the APU exhaust access fairing 317AL (Ref. TASK 52-41-18-400-001)
R or, as an alternative, the tail navigation light 15LA (Ref. TASK 33-41-
R 15-400-001).

Subtask 33-41-16-865-052

D. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LA, 2LA, 10LV, 1KD, 2KD.

Subtask 33-41-16-710-050

E. Do the operational test ot the tail navigation lights (Ref. TASK 33-41-
00-710-001) and (Ref. TASK 33-48-00-710-002).



EFF :

ALL  33-41-16

Page 406
Aug 01/07
 
IAC 
5. Close-up
________

Subtask 33-41-16-942-050

A. Remove the access platform(s).



EFF :

ALL  33-41-16

Page 407
Aug 01/07
 
IAC 
LANDING LIGHTS - DESCRIPTION AND OPERATION
__________________________________________

1. _______
General
R Two retractable landing lights are installed on the bottom of the wings at
R Zone 571 and 671. The lights operate through maximum operating speeds (VMo).

2. Component
__________________
Location
(Ref. Fig. 001)

-------------------------------------------------------------------------------
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
7LB LT-LANDING, L 571 571 33-42-11
8LB LT-LANDING, R 671 671 33-42-11

3. System
__________________
Description
(Ref. Fig. 001)
R The left-hand (LH) landing light 7LB and the right-hand (RH) landing light
R 8LB are installed on the bottom of the LH and RH wings. Each landing light
R has an independent extension/retraction and illumination circuit. Two toggle
R switches, LAND L 5LB and LAND R 6LB, control the landing light system. These
R switches are installed on the overhead panel 25VU in the cockpit. When the
R landing lights are extended, an indication LAND LT is shown on the cathode
R ray tube (CRT) as a memo message. The CRT is a part of the Electronic
R Centralized Aircraft Monitoring system (ECAM) (Ref. 31-52-00).

4. Power
____________
Supply
(Ref. Fig. 002)
R The 115V AC busbars, 101XP and 202XP, supply power to the LH and RH landing
R lights through the circuit breakers 1LB, 2LB, 3LB and 4LB. These circuit
R breakers are installed on panel 122VU in the cockpit. The circuit breakers
R 1LB and 2LB control the power supply to the LH and RH landing light
R step-down transformers. The circuit breakers 3LB and 4LB control the power
R supply to the LH and RH single-phase motors of the landing lights.

5. Interface
_________

Not Applicable



EFF :

ALL  33-42-00

Page 1
May 01/05
 
IAC 
R Landing Lights - Component Location
Figure 001



EFF :

ALL  33-42-00

Page 2
Nov 01/04
 
IAC 
R Landing Lights - Schematic
Figure 002



EFF :

ALL  33-42-00

Page 3
May 01/05
 
IAC 
6. Component
_____________________
Description
(Ref. Fig. 002)

R A. Landing Light Assembly 7LB(8LB)

Each landing light assembly has:


- a single-phase motor which has an electromagnetic brake. This is
R connected to a gearbox which moves a screw-jack that extends and
R retracts the lamp housing
- a lamp housing which has installed a 28V AC, 600 WATT, quartz,
sealed-beam unit
- a step-down transformer, which is attached to the gearbox housing
- two sealed limit microswitches
- a power relay
- a full-wave rectifier.

R B. Two toggle switches 5LB and 6LB

R The toggle switches LAND L 5LB and LAND R 6LB have three switch
R positions, which are labelled ON, OFF and RETRACT.

7. Operation/Control
________________________________
and Indicating
(Ref. Fig. 001)

R A. Two control switches 5LB and 6LB are installed on the overhead panel
R 25VU. The switch LAND L controls the left-hand landing light and the
switch LAND R controls the right-hand landing light. These switches are
operated from RETRACT to OFF to ON for extension and illumination of the
R landing lights. Then from ON to OFF to RETRACT, to set the landing lights
R to off and to retract them. These operations are as follows:

- RETRACT to OFF
Power is supplied to the extend coil of the related motor, through a
microswitch, to extend the related landing light.

- OFF to ON
Power is supplied to the related power relay, through the full-wave
rectifier and the closed contacts of a microswitch. This connects 115V
R AC, 400Hz, to the step-down transformer which decreases the voltage to
R 28V AC. The related landing light comes on.

- ON to OFF
This removes power from the related power relay and opens the contacts
of the microswitch. This removes 115V AC, 400 Hz, from the step-down
transformer and the related landing light goes off.

- OFF to RETRACT



EFF :

ALL  33-42-00

Page 4
May 01/05
 
IAC 
Power is supplied to the retract coil of the related motor, which
R retracts the related landing light. The landing light stays off.



EFF :

ALL  33-42-00

Page 5
May 01/05
 
IAC 
LANDING LIGHTS - DEACTIVATION/REACTIVATION
__________________________________________

TASK 33-42-00-040-001

Deactivation of the Landing Lights

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

WARNING : MAKE SURE THAT THERE ARE NO SIGNS OF FUEL CONTAMINATION IN THE
_______
LANDING LIGHT ASSEMBLY.
IF YOU FIND FUEL CONTAMINATION, NO PERSON MUST OPERATE THE LANDING
LIGHT UNTIL:
- YOU REPAIR THE FUEL LEAK
- YOU REPLACE THE LANDING LIGHT ASSEMBLY.
IF YOU DO NOT OBEY THIS PRECAUTION, IGNITION OF THE REMAINING FUEL IN
THE LANDING LIGHT CAN OCCUR.

1. __________________
Reason for the Job

Refer to the CDL TASK: 33-7


Landing lights: Z571, Z671

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific safety barriers
R No specific AR ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
R No specific 1 WARNING NOTICE



EFF :

ALL  33-42-00

Page 401
Feb 01/07
 
IAC 
B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 08-052 USA AMS-T-23397 AND/OR L-T-80B


SELF ADHESIVEALUMINIUM TAPE (Ref. 20-31-00)

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


R External Power
R 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
R from the External Power
33-42-00-991-002 Fig. 401

3. __________
Job Set-up

Subtask 33-42-00-941-052

A. Safety Precautions

(1) Put the safety barriers in position.

R (2) Put a WARNING NOTICE in position on panel 25VU to tell persons not to
R operate the landing lights.
R

R Subtask 33-42-00-860-051

R B. Aircraft Maintenance Configuration

R (1) Energize the aircraft electrical circuits


R (Ref. TASK 24-41-00-861-002).

R (2) If necessary, retract the applicable landing light 7LB(8LB):

R (a) In zone 571 (671), make sure the travel range of the landing
R light is clear.

R (b) In the cockpit, on the lighting panel 25VU, set the LAND L (R)
R switch to RETRACT.



EFF :

ALL  33-42-00

Page 402
Feb 01/08
 
IAC 
R (c) Make sure the landing light retracts.

R (3) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


R 002).

R (4) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE below the applicable
R zone 571(671).

Subtask 33-42-00-865-057

R C. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 7LB
122VU LIGHTING/LANDING LT/L/CTL 3LB T05
122VU LIGHTING/LANDING LT/L/SPLY 1LB T04
FOR 8LB
122VU LIGHTING/LANDING LT/R/CTL 4LB T07
122VU LIGHTING/LANDING LT/R/SPLY 2LB T06

4. Procedure
_________

(Ref. Fig. 401/TASK 33-42-00-991-002)

Subtask 33-42-00-040-050

A. Deactivation of the Landing Lights

(1) Apply BONDING AND ADHESIVE COMPOUNDS (Material No. 08-052) across the
opening of the applicable landing light 7LB(8LB).

NOTE : Make sure that the tape is correctly installed and has no
____
bubbles, wrinkles or tears in it.

(2) Write a note in the aircraft technical log that the applicable
landing light 7LB(8LB) is deactivated.



EFF :

ALL  33-42-00

Page 403
Feb 01/08
 
IAC 
R Landing Light Hole - Location
Figure 401/TASK 33-42-00-991-002



EFF :

ALL  33-42-00

Page 404
Nov 01/04
 
IAC 
5. Close-up
________

Subtask 33-42-00-942-052

R A. Removal of Equipment

(1) Remove the safety barriers.

(2) Remove the access platform(s).

R (3) Remove the warning notice(s).

R (4) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.



EFF :

ALL  33-42-00

Page 405
Feb 01/08
 
IAC 
TASK 33-42-00-440-001

Reactivation of the Landing Lights

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

WARNING : MAKE SURE THAT THERE ARE NO SIGNS OF FUEL CONTAMINATION IN THE
_______
LANDING LIGHT ASSEMBLY.
IF YOU FIND FUEL CONTAMINATION, NO PERSON MUST OPERATE THE LANDING
LIGHT UNTIL:
- YOU REPAIR THE FUEL LEAK
- YOU REPLACE THE LANDING LIGHT ASSEMBLY.
IF YOU DO NOT OBEY THIS PRECAUTION, IGNITION OF THE REMAINING FUEL IN
THE LANDING LIGHT CAN OCCUR.

1. __________________
Reason for the Job

Refer to the CDL TASK: 33-7


Landing lights: Z571, Z671

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific safety barriers


No specific AR ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific 1 WARNING NOTICE



EFF :

ALL  33-42-00

Page 406
Feb 01/08
R  
IAC 
B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-42-11-000-001 Removal of the Landing Light 7LB (8LB)


33-42-11-400-003 Installation of the Landing Light 7LB (8LB)
33-42-00-991-002 Fig. 401

3. __________
Job Set-up

Subtask 33-42-00-941-053

A. Safety Precautions

(1) Put the safety barriers in position.

R (2) Put a WARNING NOTICE in position on panel 25VU to tell persons not to
R operate the landing lights.
R

R Subtask 33-42-00-860-052

R B. Aircraft Maintenance Configuration

R (1) Make sure the applicable landing light 7LB(8LB) is retracted.

R (2) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE below the applicable
R zone 571(671).

Subtask 33-42-00-865-059

R C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 7LB
122VU LIGHTING/LANDING LT/L/CTL 3LB T05
122VU LIGHTING/LANDING LT/L/SPLY 1LB T04
FOR 8LB
122VU LIGHTING/LANDING LT/R/CTL 4LB T07
122VU LIGHTING/LANDING LT/R/SPLY 2LB T06



EFF :

ALL  33-42-00

Page 407
Feb 01/08
 
IAC 
4. Procedure
_________

(Ref. Fig. 401/TASK 33-42-00-991-002)

Subtask 33-42-00-440-050

A. Reactivation of the Landing Lights

(1) Remove the high speed tape from the opening of the applicable landing
light 7LB(8LB).

(2) Remove the applicable landing light 7LB(8LB) (Ref. TASK 33-42-11-000-
001).

(3) Install the applicable landing light 7LB(8LB) (Ref. TASK 33-42-11-
400-003).

(4) Write a note in the aircraft technical log that the applicable
landing light 7LB(8LB) is reactivated.

5. Close-up
________

Subtask 33-42-00-865-060

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
FOR 7LB
1LB, 3LB
FOR 8LB
2LB, 4LB.

Subtask 33-42-00-942-053

B. Removal of Equipment

(1) Remove the safety barriers.

(2) Remove the access platform(s).

(3) Remove the warning notice(s).

(4) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.



EFF :

ALL  33-42-00

Page 408
Feb 01/08
 
IAC 
LANDING LIGHTS - ADJUSTMENT/TEST
________________________________

TASK 33-42-00-710-001

Operational Test of the Landing Lights

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

WARNING : MAKE SURE THAT THERE ARE NO SIGNS OF FUEL CONTAMINATION IN THE
_______
LANDING LIGHT ASSEMBLY.
IF YOU FIND FUEL CONTAMINATION, NO PERSON MUST OPERATE THE LANDING
LIGHT UNTIL:
- YOU REPAIR THE FUEL LEAK
- YOU REPLACE THE LANDING LIGHT ASSEMBLY.
IF YOU DO NOT OBEY THIS PRECAUTION, IGNITION OF THE REMAINING FUEL IN
THE LANDING LIGHT CAN OCCUR.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific safety barriers


R No specific 1 WARNING NOTICE



EFF :

ALL  33-42-00

Page 501
Feb 01/07
 
IAC 
B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-42-00-941-051

A. Safety Precautions

(1) Put the safety barriers in position.


R

R (2) Put a WARNING NOTICE in position on the panel 25VU to tell persons
not to operate the landing lights.

Subtask 33-42-00-861-050

B. Aircraft Maintenance Configuration

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

Subtask 33-42-00-865-050

C. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/LANDING LT/R/CTL 4LB T07
122VU LIGHTING/LANDING LT/R/SPLY 2LB T06
122VU LIGHTING/LANDING LT/L/CTL 3LB T05
122VU LIGHTING/LANDING LT/L/SPLY 1LB T04



EFF :

ALL  33-42-00

Page 502
Feb 01/07
 
IAC 
4. Procedure
_________

Subtask 33-42-00-710-050

R A. Operational Test of the Landing Lights

R CAUTION : DO NOT OPERATE THE RETRACTABLE LANDING LIGHT 7LB (8LB) FOR MORE
_______
R THAN ONE MINUTE WHEN THE AIRCRAFT IS ON THE GROUND. THE LANDING
R LIGHT CAN BECOME DAMAGED IF IT OPERATES WITH NO AIRFLOW TO KEEP
R THE LIGHT UNIT COOL. MAKE SURE THAT THERE IS A MINIMUM PERIOD
R OF FIVE MINUTES BETWEEN EACH OPERATION, TO LET THE TEMPERATURE
R OF THE LIGHT UNIT DECREASE.

(1) Make sure that the travel range(s) of the applicable landing light(s)
is(are) clear.

(2) Do this test:

NOTE : This test is for the left landing light. For the right landing
____
light, use the indications in parenthesis.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

On panel 25VU: At zone 571(671):

1. Set the LAND L(LAND R) switch to - the landing light extends fully in
OFF. not more than 10 seconds.

2. Set the LAND L(LAND R) switch to - the landing light comes on.
ON.

3. Set the LAND L(LAND R) switch to - the landing light goes off.
OFF.

4. Set the LAND L(LAND R) switch to - the landing light retracts in not
RETRACT. more than 10 seconds.

5. Set the LAND L(LAND R) switch to - the landing light extends


ON. - before the landing light is fully
extended, the light comes on.

6. Set the LAND L(LAND R) switch to - the landing light retracts


RETRACT. - after the landing light starts to
retract, the light goes off.



EFF :

ALL  33-42-00

Page 503
Feb 01/07
 
IAC 
5. Close-up
________

Subtask 33-42-00-862-050

A. Aircraft Maintenance Configuration

(1) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).

Subtask 33-42-00-942-051

B. Removal of Equipment

(1) Remove the safety barriers.

(2) Remove the warning notice(s).

(3) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.


R

EFF :

ALL  33-42-00

Page 504
Nov 01/02
 
IAC 
**ON A/C 001-012, 014-019,

TASK 33-42-00-820-001

Adjustment of the Extension Angle of the Landing Lights

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

WARNING : MAKE SURE THAT THERE ARE NO SIGNS OF FUEL CONTAMINATION IN THE
_______
LANDING LIGHT ASSEMBLY.
IF YOU FIND FUEL CONTAMINATION, NO PERSON MUST OPERATE THE LANDING
LIGHT UNTIL:
- YOU REPAIR THE FUEL LEAK
- YOU REPLACE THE LANDING LIGHT ASSEMBLY.
IF YOU DO NOT OBEY THIS PRECAUTION, IGNITION OF THE REMAINING FUEL IN
THE LANDING LIGHT CAN OCCUR.

1. __________________
Reason for the Job

R
R Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific safety barriers
No specific vernier protractor
No specific warning notice
No specific access platform 2.8 m (9 ft. 2 in.)



EFF :

001-012, 014-019,  33-42-00

Page 505
Nov 01/03
 
IAC 
B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
33-42-00-710-001 Operational Test of the Landing Lights
33-42-00-991-001 Fig. 501

3. __________
Job Set-up

Subtask 33-42-00-941-050

A. Safety Precautions

(1) Put the safety barriers in position.

(2) Put a warning notice in position on panel 25VU to tell persons not to
operate the landing lights.

Subtask 33-42-00-010-050

B. Get Access

(1) put an access platform below the applicable landing light.

Subtask 33-42-00-865-051

C. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/LANDING LT/R/CTL 4LB T07
122VU LIGHTING/LANDING LT/R/SPLY 2LB T06
122VU LIGHTING/LANDING LT/L/CTL 3LB T05
122VU LIGHTING/LANDING LT/L/SPLY 1LB T04



EFF :

001-012, 014-019,  33-42-00

Page 506
Nov 01/02
R  
IAC 
Subtask 33-42-00-860-050

D. Aircraft Maintenance Configuration

(1) Make sure that the travel range of the applicable landing light is
clear.

(2) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

4. Procedure
_________

(Ref. Fig. 501/TASK 33-42-00-991-001)

Subtask 33-42-00-865-052

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
3LB, 4LB

Subtask 33-42-00-220-050

B. Measure the Extension Angle

(1) Do the applicable adjustment steps that follow.

NOTE : The subsequent steps are for the left landing light. For the
____
right landing light, use the indications in parenthesis.

(2) On panel 25VU, set the LAND L(LAND R) switch to the OFF position.

(3) Measure the extension angle of the landing light with a vernier
protractor. Use the rear of the lamp housing as the datum surface.

(4) If the extension angle is not between 90 degrees maximum and 88


degrees minimum, do the applicable subsequent steps.

Subtask 33-42-00-865-053

C. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/LANDING LT/R/CTL 4LB T07
122VU LIGHTING/LANDING LT/L/CTL 3LB T05



EFF :

001-012, 014-019,  33-42-00

Page 507
Nov 01/02
R  
IAC 
Landing-Light Extension-Limit-Switch Assembly
Figure 501/TASK 33-42-00-991-001



EFF :

001-012, 014-019,  33-42-00

Page 508
Nov 01/02
R  
IAC 
Subtask 33-42-00-820-052

D. Adjustment of the Extension Angle of the Landing Lights

CAUTION : DO NOT MAKE THE EXTENSION ANGLE MORE THAN 90 DEGS. THIS CAN
_______
CAUSE DAMAGE TO THE MOTOR.

(1) Turn the adjustment screw of the extension limit switch:


- clockwise to decrease the extension angle
- counterclockwise to increase the extension angle.

NOTE : Do the adjustment with small movements each time. Always


____
adjust the light ON/OFF switch by the same amount (and in the
same direction) when you adjust the extension limit switch.

Subtask 33-42-00-220-051

E. Measure the Extension Angle

WARNING : MAKE SURE THAT THE TRAVEL RANGE OF THE LANDING LIGHT REMAINS
_______
CLEAR.
IF AN ADJUSTMENT IS MADE, IT IS POSSIBLE THAT THE LANDING LIGHT
WILL MOVE.

(1) Make sure that the landing light is in the extended position with the
adjustment screw against the extension limit switch.

(2) Measure the extension angle of the landing light again.

(3) If necessary, do the adjustment steps again until the extension angle
is correct.

Subtask 33-42-00-865-056

F. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LB, 2LB, 3LB, 4LB.

Subtask 33-42-00-710-051

G. Operational Test

(1) On panel 25VU, put the applicable landing light switch to the RETRACT
position.

(2) Do an operational test of the applicable landing light (Ref. TASK 33-
42-00-710-001).



EFF :

001-012, 014-019,  33-42-00

Page 509
Nov 01/02
R  
IAC 
5. Close-up
________

Subtask 33-42-00-862-051

A. Aircraft Maintenance Configuration

(1) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).

Subtask 33-42-00-942-050

B. Removal of Equipment

(1) Remove the safety barriers.

(2) Remove the warning notice(s).

(3) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.



EFF :

001-012, 014-019,  33-42-00

Page 510
Nov 01/02
 
IAC 
LIGHT - LANDING (7LB,8LB) - REMOVAL/INSTALLATION
________________________________________________

TASK 33-42-11-000-001

Removal of the Landing Light 7LB (8LB)

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

WARNING : MAKE SURE THAT THERE ARE NO SIGNS OF FUEL CONTAMINATION IN THE
_______
LANDING LIGHT ASSEMBLY.
IF YOU FIND FUEL CONTAMINATION, NO PERSON MUST OPERATE THE LANDING
LIGHT UNTIL:
- YOU REPAIR THE FUEL LEAK
- YOU REPLACE THE LANDING LIGHT ASSEMBLY.
IF YOU DO NOT OBEY THIS PRECAUTION, IGNITION OF THE REMAINING FUEL IN
THE LANDING LIGHT CAN OCCUR.

R CAUTION : WHEN YOU REPLACE A LANDING LIGHT ASSEMBLY, EXAMINE THE APPLICABLE
_______
R LANDING LIGHT ASSEMBLY FOR SIGNS OF FUEL CONTAMINATION. IF YOU FIND
R FUEL CONTAMINATION, EXAMINE THE ITEMS THAT FOLLOW FOR SIGNS OF FUEL
R LEAKAGE:
R - THE FUEL PUMP(S) 21QA(26QA) OR 25QA(22QA)
R - THE WATER DRAIN VALVE 25QM(26QM) DIRECTLY FORWARD OF THE LANDING
R LIGHT ASSEMBLY.
R REFER TO AMM 28-11-00-06 FOR LEAKAGE LIMITS AND REPAIR AS NECESSARY.
R IF YOU DO NOT REPAIR THE LEAK, NO PERSONS MUST OPERATE THE APPLICABLE
R LANDING LIGHT UNTIL:
R - THE LEAK IS REPAIRED
R - THE LANDING LIGHT ASSEMBLY IS REPLACED.

1. __________________
Reason for the Job

Self Explanatory



EFF :

ALL  33-42-11

Page 401
May 01/04
 
IAC 
2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific safety barriers
No specific warning notice
No specific access platform 2.8 m (9 ft. 2 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

28-11-00-280-002 Fuel Tank Leak Checks


28-11-41-000-003 Removal of the Water Drain Valve 25QM (26QM)
28-21-51-000-001 Removal of the Fuel Pumps 21QA(26QA) and 25QA(22QA)
33-42-11-991-002 Fig. 401

3. __________
Job Set-up

Subtask 33-42-11-941-052

A. Safety Precautions

(1) Put the safety barriers in position.

(2) Put a warning notice in the cockpit to tell persons not to operate
the landing lights.



EFF :

ALL  33-42-11

Page 402
May 01/06
R  
IAC 
Subtask 33-42-11-865-050

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/LANDING LT/R/CTL 4LB T07
122VU LIGHTING/LANDING LT/R/SPLY 2LB T06
122VU LIGHTING/LANDING LT/L/CTL 3LB T05
122VU LIGHTING/LANDING LT/L/SPLY 1LB T04

Subtask 33-42-11-010-050

C. Get Access

(1) Put the access platform in position as applicable:


- FOR 7LB
below zone 571
- FOR 8LB
below zone 671.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-42-11-991-002)

Subtask 33-42-11-210-058

A. Examine the Landing Light Assembly for Fuel Contamination

(1) Examine the landing light assembly for signs of fuel contamination.

(2) If you find fuel contamination, examine the items that follow for
fuel leakage:
- the fuel pumps 21QA(26QA) and 25QA(22QA) (Ref. TASK 28-21-51-000-
001)
- the water drain valve 25QM(26QM) (Ref. TASK 28-11-41-000-003)
- the wing tank structure (Ref. TASK 28-11-00-280-002).
Repair the leak(s) as necessary.



EFF :

ALL  33-42-11

Page 403
Aug 01/06
 
IAC 
Landing Light 7LB (8LB)
Figure 401/TASK 33-42-11-991-002



EFF :

ALL  33-42-11

Page 404
Nov 01/02
R  
IAC 
Subtask 33-42-11-020-050

B. Removal of the Landing Light

(1) Disconnect the electrical connector (4) from the light assembly (1).

(2) Put a blanking cap on the disconnected electrical connector.

(3) Remove the screws (2).

(4) Remove the light assembly (1).



EFF :

ALL  33-42-11

Page 405
May 01/06
R  
IAC 
TASK 33-42-11-400-003

Installation of the Landing Light 7LB (8LB)

WARNING : MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING
_______
NOTICES ARE IN POSITION.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

WARNING : MAKE SURE THAT THERE ARE NO SIGNS OF FUEL CONTAMINATION IN THE
_______
LANDING LIGHT ASSEMBLY.
IF YOU FIND FUEL CONTAMINATION, NO PERSON MUST OPERATE THE LANDING
LIGHT UNTIL:
- YOU REPAIR THE FUEL LEAK
- YOU REPLACE THE LANDING LIGHT ASSEMBLY.
IF YOU DO NOT OBEY THIS PRECAUTION, IGNITION OF THE REMAINING FUEL IN
THE LANDING LIGHT CAN OCCUR.

CAUTION : WHEN YOU REPLACE A LANDING LIGHT ASSEMBLY, EXAMINE THE APPLICABLE
_______
LANDING LIGHT ASSEMBLY FOR SIGNS OF FUEL CONTAMINATION. IF YOU FIND
FUEL CONTAMINATION, EXAMINE THE ITEMS THAT FOLLOW FOR SIGNS OF FUEL
LEAKAGE:
- THE FUEL PUMP(S) 21QA(26QA) OR 25QA(22QA)
- THE WATER DRAIN VALVE 25QM(26QM) DIRECTLY FORWARD OF THE LANDING
LIGHT ASSEMBLY.
REFER TO AMM 28-11-00-06 FOR LEAKAGE LIMITS AND REPAIR AS NECESSARY.
IF YOU DO NOT REPAIR THE LEAK, NO PERSONS MUST OPERATE THE APPLICABLE
LANDING LIGHT UNTIL:
- THE LEAK IS REPAIRED
- THE LANDING LIGHT ASSEMBLY IS REPLACED.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific safety barriers


No specific warning notice
No specific access platform 2.8 m (9 ft. 2 in.)



EFF :

ALL  33-42-11

Page 406
May 01/06
R  
IAC 
B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 08-004A USA MIL-A-46106 TYPE I


ADHESIVE SEALANT (Ref. 20-31-00)
Material No. 11-026 GB DEF-STAN 68-148/1
SOLVENT GENERAL PURPOSE (Ref. 20-31-00)
R Material No. 15-008 AIB TN 10138 TYPE II GRADE 2
R CORROSION PREVENTIVE TEMPORARY PROTECTIVE COMPOUND
R (Ref. 20-31-00)
Material No. 19-003 USA AMS 3819
LINT-FREE COTTON CLOTH (Ref. 20-31-00)

C. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

3 seal 33-42-05 01 -040

D. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-42-00-710-001 Operational Test of the Landing Lights


33-42-00-820-001 Adjustment of the Extension Angle of the Landing
Lights
33-42-11-991-002 Fig. 401

3. __________
Job Set-up

Subtask 33-42-11-941-055

A. Safety Precautions

(1) Make sure that the safety barriers are in position.

(2) Make sure that the warning notice is in the cockpit to tell persons
not to operate the landing lights.



EFF :

ALL  33-42-11

Page 407
May 01/06
 
IAC 
Subtask 33-42-11-865-051

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/LANDING LT/R/CTL 4LB T07
122VU LIGHTING/LANDING LT/R/SPLY 2LB T06
122VU LIGHTING/LANDING LT/L/CTL 3LB T05
122VU LIGHTING/LANDING LT/L/SPLY 1LB T04

Subtask 33-42-11-860-050

C. Aircraft Maintenance Configuration

(1) Make sure that the access platform is in position.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-42-11-991-002)

Subtask 33-42-11-420-050

A. Preparation for Installation

(1) Clean the component interface and/or the adjacent area with a clean
MISCELLANEOUS (Material No. 19-003) made moist with CLEANING AGENTS
(Material No. 11-026).

(2) Make sure that the parts retained from the removed component are
clean and in the correct condition.

(3) Do an inspection of the component interface and/or the adjacent area.

(4) If the seal (3) is damaged you must replace it as follows:

(a) Remove and discard the seal (3).

(b) Clean the light assembly interface with a clean MISCELLANEOUS


(Material No. 19-003) made moist with CLEANING AGENTS (Material
No. 11-026).



EFF :

ALL  33-42-11

Page 408
Aug 01/06
 
IAC 
(c) Apply Prime coating 1200 on the light assembly (1) and install
the seal (3) with BONDING AND ADHESIVE COMPOUNDS (Material No.
08-004A).

(5) If you install the assembly you removed, examine the lamp reflector,
the lamp glass and the electrical connector for correct condition.

**ON A/C 001-012, 014-019,

Subtask 33-42-11-420-052

B. Installation of the Landing Light

(1) Install the light assembly (1) on the wing bottom skin.

(2) Install the screws (2).

(3) Remove the blanking cap from the electrical connector (4).

(4) Make sure that the electrical connector (4) is in the correct
condition.

(5) Connect the electrical connector (4) to the light assembly (1). Make
sure that the connector orientation will let you install a drip loop.
(Ref. Fig. 401/TASK 33-42-11-991-002)

(6) Make sure that the extension angle of the landing light is correct
(Ref. TASK 33-42-00-820-001).

**ON A/C 020-099,

Subtask 33-42-11-420-052-A

B. Installation of the Landing Light

(1) Install the light assembly (1) on the wing bottom skin.

(2) Install the screws (2).

(3) Remove the blanking cap from the electrical connector (4).

(4) Make sure that the electrical connector (4) is in the correct
condition.



EFF :

ALL  33-42-11

Page 409
Aug 01/06
R  
IAC 
(5) Connect the electrical connector (4) to the light assembly (1). Make
sure that the connector orientation will let you install a drip loop.
(Ref. Fig. 401/TASK 33-42-11-991-002)

R **ON A/C 101-199, 901-999,

Subtask 33-42-11-420-052-B

B. Installation of the Landing Light

(1) Install the light assembly (1) on the wing bottom skin.

(2) Install the screws (2).

(3) Remove the blanking cap from the electrical connector (4).

(4) Make sure that the electrical connector (4) is in the correct
condition.

(5) Connect the electrical connector (4) to the light assembly (1). Make
sure that the connector orientation will let you install a drip loop.
(Ref. Fig. 401/TASK 33-42-11-991-002)

(6) Clean the electrical connector (4) with a MISCELLANEOUS (Material No.
19-003) made moist with CLEANING AGENTS (Material No. 11-026).

(7) Apply a continuous layer of STORAGE PRESERVATION (Material No. 15-


008) to the electrical connector (4).

**ON A/C ALL

Subtask 33-42-11-865-058

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LB, 2LB, 3LB, 4LB.



EFF :

ALL  33-42-11

Page 410
Feb 01/07
 
IAC 
Subtask 33-42-11-710-051

D. Operational Test

(1) Do an operational test of the applicable landing light (Ref. TASK 33-
42-00-710-001).

(2) Clean the landing light glass with a clean MISCELLANEOUS (Material
No. 19-003).

5. Close-up
________

Subtask 33-42-11-942-050

A. Removal of Equipment

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the safety barriers.

(3) Remove the warning notice(s).

(4) Remove the access platform(s).

(5) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.



EFF :

ALL  33-42-11

Page 411
Aug 01/06
R  
IAC 
TASK 33-42-11-000-002

Removal of the Landing Light Lamp

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

WARNING : MAKE SURE THAT THERE ARE NO SIGNS OF FUEL CONTAMINATION IN THE
_______
LANDING LIGHT ASSEMBLY.
IF YOU FIND FUEL CONTAMINATION, NO PERSON MUST OPERATE THE LANDING
LIGHT UNTIL:
- YOU REPAIR THE FUEL LEAK
- YOU REPLACE THE LANDING LIGHT ASSEMBLY.
IF YOU DO NOT OBEY THIS PRECAUTION, IGNITION OF THE REMAINING FUEL IN
THE LANDING LIGHT CAN OCCUR.

CAUTION : WHEN YOU REPLACE A LANDING LIGHT LAMP, EXAMINE THE APPLICABLE LANDING
_______
LIGHT ASSEMBLY FOR SIGNS OF FUEL CONTAMINATION. IF YOU FIND FUEL
CONTAMINATION, EXAMINE THE ITEMS THAT FOLLOW FOR SIGNS OF FUEL
LEAKAGE:
- THE FUEL PUMP(S) 21QA(26QA) OR 25QA(22QA)
- THE WATER DRAIN VALVE 25QM(26QM) DIRECTLY FORWARD OF THE LANDING
LIGHT ASSEMBLY.
REFER TO AMM 28-11-00-06 FOR LEAKAGE LIMITS AND REPAIR AS NECESSARY.
IF YOU DO NOT REPAIR THE LEAK, NO PERSONS MUST OPERATE THE APPLICABLE
LANDING LIGHT UNTIL:
- THE LEAK IS REPAIRED
- THE LANDING LIGHT ASSEMBLY IS REPLACED.

1. __________________
Reason for the Job

Self Explanatory



EFF :

ALL  33-42-11

Page 412
May 01/06
R  
IAC 
2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific safety barriers
No specific warning notice
No specific access platform 1.0 m (3 ft. 3 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
28-11-00-280-002 Fuel Tank Leak Checks
28-11-41-000-003 Removal of the Water Drain Valve 25QM (26QM)
28-21-51-000-001 Removal of the Fuel Pumps 21QA(26QA) and 25QA(22QA)
33-42-11-991-004 Fig. 402

3. __________
Job Set-up

Subtask 33-42-11-941-053

A. Safety Precautions

(1) Put the safety barriers in position.

(2) Put a warning notice in the cockpit to tell persons not to operate
the landing lights.

Subtask 33-42-11-010-051

B. Get Access

(1) Put the access platform below the applicable landing light.



EFF :

ALL  33-42-11

Page 413
May 01/06
R  
IAC 
Subtask 33-42-11-860-051

C. Aircraft Maintenance Configuration

(1) Energize the aircraft electrical circuits


(Ref. TASK 24-41-00-861-002).

(2) Extend the landing light:

(a) In zone 571 (671), make sure the travel range of the landing
light is clear.

(b) In the cockpit, on the lighting panel 25VU, set the LAND L (R)
switch to OFF.

(c) Make sure the landing light extends.

(3) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).

Subtask 33-42-11-865-055

D. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/LANDING LT/R/CTL 4LB T07
122VU LIGHTING/LANDING LT/R/SPLY 2LB T06
122VU LIGHTING/LANDING LT/L/CTL 3LB T05
122VU LIGHTING/LANDING LT/L/SPLY 1LB T04



EFF :

ALL  33-42-11

Page 414
Aug 01/06
 
IAC 
R **ON A/C ALL

4. Procedure
_________

Subtask 33-42-11-210-059

A. Examine the Landing Light Assembly for Fuel Contamination

(1) Examine the landing light assembly for signs of fuel contamination.

(2) If you find fuel contamination, examine the items that follow for
fuel leakage:
- the fuel pumps 21QA(26QA) and 25QA(22QA) (Ref. TASK 28-21-51-000-
001)
- the water drain valve 25QM(26QM) (Ref. TASK 28-11-41-000-003)
- the wing tank structure (Ref. TASK 28-11-00-280-002).
Repair the leak(s) as necessary.

Subtask 33-42-11-020-052

B. Removal of the Landing Light Lamp


(Ref. Fig. 402/TASK 33-42-11-991-004)

(1) Hold the lamp (7) and remove the screw (5) and the clamp (6).

(2) Remove the lamp (7) from the lamp housing (1) to get access to the
electrical terminals (3).

(3) Remove the screws (2) and disconnect the two electrical terminals
(3). Remove the lamp (7).



EFF :

ALL  33-42-11

Page 415
May 01/06
 
IAC 
Landing Light Lamp
Figure 402/TASK 33-42-11-991-004



EFF :

ALL  33-42-11

Page 416
May 01/06
R  
IAC 
TASK 33-42-11-400-004

Installation of the Landing Light Lamp

WARNING : MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING
_______
NOTICES ARE IN POSITION.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

WARNING : MAKE SURE THAT THERE ARE NO SIGNS OF FUEL CONTAMINATION IN THE
_______
LANDING LIGHT ASSEMBLY.
IF YOU FIND FUEL CONTAMINATION, NO PERSON MUST OPERATE THE LANDING
LIGHT UNTIL:
- YOU REPAIR THE FUEL LEAK
- YOU REPLACE THE LANDING LIGHT ASSEMBLY.
IF YOU DO NOT OBEY THIS PRECAUTION, IGNITION OF THE REMAINING FUEL IN
THE LANDING LIGHT CAN OCCUR.

CAUTION : WHEN YOU REPLACE A LANDING LIGHT LAMP, EXAMINE THE APPLICABLE LANDING
_______
LIGHT ASSEMBLY FOR SIGNS OF FUEL CONTAMINATION. IF YOU FIND FUEL
CONTAMINATION, EXAMINE THE ITEMS THAT FOLLOW FOR SIGNS OF FUEL
LEAKAGE:
- THE FUEL PUMP(S) 21QA(26QA) OR 25QA(22QA)
- THE WATER DRAIN VALVE 25QM(26QM) DIRECTLY FORWARD OF THE LANDING
LIGHT ASSEMBLY.
REFER TO AMM 28-11-00-06 FOR LEAKAGE LIMITS AND REPAIR AS NECESSARY.
IF YOU DO NOT REPAIR THE LEAK, NO PERSONS MUST OPERATE THE APPLICABLE
LANDING LIGHT UNTIL:
- THE LEAK IS REPAIRED
- THE LANDING LIGHT ASSEMBLY IS REPLACED.

1. __________________
Reason for the Job

Self Explanatory



EFF :

ALL  33-42-11

Page 417
May 01/06
R  
IAC 
2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

R No specific AR ACCESS PLATFORM 1M (3 FT)


R No specific AR SAFETY BARRIER
R No specific 1 WARNING NOTICE
R No specific Torque Wrench : range 0.00 to 1.20 m.daN
R (0.00 to 9.00 lbf.ft)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
33-42-00-710-001 Operational Test of the Landing Lights
33-42-11-991-004 Fig. 402

3. __________
Job Set-up

Subtask 33-42-11-941-056

A. Safety Precautions

R (1) Make sure that the SAFETY BARRIERS are in position.

R (2) Make sure that the WARNING NOTICE is in position to tell persons not
to operate the landing lights.

Subtask 33-42-11-860-052

B. Aircraft Maintenance Configuration

(1) Make sure that the landing light is in the extended position.

(2) Make sure that the LAND L (R) switch (in the cockpit) is set to OFF
position.



EFF :

ALL  33-42-11

Page 418
May 01/07
 
IAC 
R (3) Make sure that the ACCESS PLATFORM 1M (3 FT) is in position below the
applicable landing light.

Subtask 33-42-11-865-056

C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/LANDING LT/R/CTL 4LB T07
122VU LIGHTING/LANDING LT/R/SPLY 2LB T06
122VU LIGHTING/LANDING LT/L/CTL 3LB T05
122VU LIGHTING/LANDING LT/L/SPLY 1LB T04

4. Procedure
_________

Subtask 33-42-11-420-053

A. Preparation for Installation

(1) Do an inspection of the component interface and/or the adjacent area.

(2) Make sure that the parts retained from the removed component are
clean and in the correct condition.

(3) Make sure that the electrical terminals (3) and the lamp terminals
(7) are clean and in the correct condition.

NOTE : All signs of corrosion, contamination and lacquer must be


____
removed to make sure of a good electrical connection.

Subtask 33-42-11-420-051

R B. Installation of the Landing Light Lamp


(Ref. Fig. 402/TASK 33-42-11-991-004)

(1) Make sure the seal (4) is correctly installed in the lamp housing
(1).

(2) Connect the two electrical terminals (3) to the lamp (7) with the
screws (2). Tighten the screws (2).

(3) Install the lamp (7) in the lamp housing (1). Make sure the filament
of the lamp is horizontal, as shown on the filament position plate
(8).



EFF :

ALL  33-42-11

Page 419
May 01/07
 
IAC 
(4) Install the clamp (6) with the screw (5). Tighten the screw (5).

R (5) Torque the screw (5) to 0.0751 m.daN (6.64 lbf.in).

Subtask 33-42-11-865-057

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LB, 2LB, 3LB, 4LB.

Subtask 33-42-11-710-052

D. Operational Test

(1) Do the operational test of the landing light (Ref. TASK 33-42-00-710-
001).

5. Close-up
________

Subtask 33-42-11-860-053

R A. Aircraft Maintenance Configuration


R

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

(2) Retract the landing light.

(3) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).

Subtask 33-42-11-942-051

B. Removal of Equipment

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the safety barriers.

(3) Remove the warning notice(s).

(4) Remove the access platform(s).



EFF :

ALL  33-42-11

Page 420
May 01/07
 
IAC 
(5) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.



EFF :

ALL  33-42-11

Page 421
May 01/06
 
IAC 
RUNWAY TURNOFF LIGHTS - DESCRIPTION AND OPERATION
_________________________________________________

1. _______
General
The runway turnoff lights illuminate the lateral areas of the runway.
Two light units are installed on the nose landing gear.

2. Component
__________________
Location
(Ref. Fig. 001)

_______________________________________________________________________________
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
2LC SW-EXT LT/RWY TURN OFF 25VU 210
3LC1 LT-RUNWAY TURNOFF, L 711 33-43-11
3LC2 LT-RUNWAY TURNOFF, R 711 33-43-11
6LC RELAY-PWR SPLY, RWY TURN OFF LT 103VU 126

3. ___________
Description
(Ref. Fig. 002)
The runway turnoff-light system consists of:
R - two single-filament lamps (or halogen lamps in alternate solution) 3LC1
R and 3LC2, which are installed in a fixed position on the nose landing
R gear. Each lamp is rated at 150 Watts.
- a transformer, which produces the rated operating voltage
- a power control relay 6LC
- a control switch 2LC, which is installed in the cockpit on the overhead
panel.

4. _________
Operation
(Ref. Fig. 002)
The 115 VAC busbars 204XP and 103XP supply power to the runway turnoff-light
system, through circuit breakers 1LC1 and 1LC2. A switch 2LC controls the
control circuit, it gets power from the 28 VDC busbar 202PP through circuit
breaker 2LR. A ground signal for the power control relay 6LC is available
from the landing gear computer.
The ground signal is connected, when the nose landing gear is locked down.
The power control relay 6LC and the control switch 2LC get power when the
busbars are energized and the circuit breakers are closed. The runway
turnoff lights come on when the switch 2LC is in the RWY TURN OFF position.
When the nose landing gear is unlocked, the ground signal for the power
control relay is disconnected. The runway turnoff lights 3LC1 and 3LC2 go
off.



EFF :

ALL  33-43-00

Page 1
May 01/06
 
IAC 
R Runway Turnoff Lights - Component Location
Figure 001



EFF :

ALL  33-43-00

Page 2
May 01/06
 
IAC 
Runway Turnoff Lights - Schematic
Figure 002



EFF :

ALL  33-43-00

Page 3
Feb 01/96
 
IAC 
RUNWAY TURNOFF LIGHTS - DEACTIVATION/REACTIVATION
_________________________________________________

TASK 33-43-00-040-002

Deactivation of the Runway Turnoff Light (3LC1, 3LC2)

1. __________________
Reason for the Job

Refer to the CDL TASK: 33-8


Turn Off Light

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific soap solution

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 05-065 C Z-24.380


EROSION PROTECTIVE TAPE (Ref. 20-31-00)
Material No. 08-052 USA AMS-T-23397 AND/OR L-T-80B
SELF ADHESIVEALUMINIUM TAPE (Ref. 20-31-00)
Material No. 19-003 USA AMS 3819
LINT-FREE COTTON CLOTH (Ref. 20-31-00)

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-43-11-000-001 Removal of the Runway Turnoff Light (3LC1, 3LC2)


R



EFF :

ALL  33-43-00

Page 401
Feb 01/08
 
IAC 
3. __________
Job Set-up

Subtask 33-43-00-941-051

A. Safety Precautions

(1) Put a warning notice in position on the EXT LT section of the


overhead panel 25VU to tell persons not to operate the runway turnoff
lights.

Subtask 33-43-00-865-053

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/RWY TURN OFF/L 1LC1 W06
122VU LIGHTING/EXT LT/RWY TURN OFF/R 1LC2 W05

4. Procedure
_________

Subtask 33-43-00-040-051

A. Deactivation of the Runway Turnoff Light

CAUTION : IF THE LAMP IS REMOVED, SAFETY THE WIRES WITH HIGH-SPEED TAPE.
_______

R (1) You must remove (Ref. TASK 33-43-11-000-001) the runway turnoff light
R if there are these two conditions:
- if there are cracks on the front face, and
- if there is movement of the parts of the front glass (the
supporting structure does not hold them tightly).

R (2) If you do not remove the cracked runway turnoff-light, you can do an
alternative repair as follows:

R NOTE : This repair is only applicable for cracks. If the lens is


____
R broken, the runway turnoff light must be removed.

(a) Clean the surface of the runway turnoff-light lens with


MISCELLANEOUS (Material No. 19-003) made moist with warm soap
solution.

(b) Dry the surface of the runway turnoff-light lens with a clean
MISCELLANEOUS (Material No. 19-003).



EFF :

ALL  33-43-00

Page 402
Feb 01/08
 
IAC 
(c) Apply SPECIAL MATERIALS (Material No. 05-065) or BONDING AND
ADHESIVE COMPOUNDS (Material No. 08-052) to cover the crack(s).

NOTE : Make sure that the tape is correctly installed and has no
____
bubbles, wrinkles or tears in it.

R (d) Let the tape cure for 15 minutes minimum at a minimum temperature
R of 15 deg.C (59.00 deg.F)

(3) If it is not necessary to replace the runway turnoff light, write in


the aircraft technical log that the runway turnoff light is damaged.

5. Close-up
________

Subtask 33-43-00-865-054

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LC1, 1LC2.

Subtask 33-43-00-942-052

B. Put the aircraft back to its initial configuration.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the warning notice(s).



EFF :

ALL  33-43-00

Page 403
Feb 01/08
 
IAC 
TASK 33-43-00-440-002

Reactivation of the Runway Turnoff Light (3LC1, 3LC2)

1. __________________
Reason for the Job

Refer to the CDL TASK: 33-8


Turn Off Light

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-43-11-000-001 Removal of the Runway Turnoff Light (3LC1, 3LC2)


33-43-11-400-001 Installation of the Runway Turnoff Light (3LC1, 3LC2)

3. __________
Job Set-up

Subtask 33-43-00-941-052

A. Safety Precautions

(1) Put a warning notice in position on the EXT LT section of the


overhead panel 25VU to tell persons not to operate the runway turnoff
lights.

Subtask 33-43-00-865-055

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/RWY TURN OFF/L 1LC1 W06
122VU LIGHTING/EXT LT/RWY TURN OFF/R 1LC2 W05



EFF :

ALL  33-43-00

Page 404
Aug 01/07
R  
IAC 
4. Procedure
_________

Subtask 33-43-00-440-050

A. Reactivation of the Runway Turnoff Light

(1) Replace the runway turnoff light (Ref. TASK 33-43-11-000-001) and
(Ref. TASK 33-43-11-400-001).

5. Close-up
________

Subtask 33-43-00-865-056

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LC1, 1LC2.

Subtask 33-43-00-942-053

B. Put the aircraft back to its initial configuration.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the warning notice(s).



EFF :

ALL  33-43-00

Page 405
Aug 01/07
R  
IAC 
RUNWAY TURNOFF LIGHTS - ADJUSTMENT/TEST
_______________________________________

TASK 33-43-00-710-001

Operational Test of the Runway Turnoff Lights

1. __________________
Reason for the Job

Make sure that the turnoff lights operate correctly.

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-43-00-861-051

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-43-00-865-050

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/CTL 2LR W09
122VU LIGHTING/EXT LT/RWY TURN OFF/L 1LC1 W06
122VU LIGHTING/EXT LT/RWY TURN OFF/R 1LC2 W05



EFF :

ALL  33-43-00

Page 501
Aug 01/06
 
IAC 
R

4. Procedure
_________

Subtask 33-43-00-710-050

A. Operational Test of Lights

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

On the panel 25VU: On the nose landing gear:


- set the RWY TURN OFF switch to ON, - the runway turnoff lights come on,

- set the RWY TURN OFF switch to - the runway turnoff lights go off.
OFF.

5. Close-up
________

Subtask 33-43-00-862-051

A. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-43-00

Page 502
Aug 01/06
 
IAC 
LIGHT - RUNWAY TURNOFF (3LC1,3LC2) - REMOVAL/INSTALLATION
_________________________________________________________

TASK 33-43-11-000-001

Removal of the Runway Turnoff Light (3LC1, 3LC2)

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2 MINUTES


_______
AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking cap


No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-43-11-991-001 Fig. 401



EFF :

ALL  33-43-11

Page 401
May 01/06
R  
IAC 
3. __________
Job Set-up

Subtask 33-43-11-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 3LC1
R
122VU LIGHTING/EXT LT/RWY TURN OFF/L 1LC1 W06
R
FOR 3LC2
R
122VU LIGHTING/EXT LT/RWY TURN OFF/R 1LC2 W05

4. Procedure
_________

(Ref. Fig. 401/TASK 33-43-11-991-001)

Subtask 33-43-11-020-050

A. Removal of the Light

(1) Disconnect the electrical connector (5) from its support.

(2) Put the blanking cap on the disconnected electrical connector (5) and
on its support.

(3) Remove the two nuts (1) and the washers (2). During this operation,
hold the optical unit.

(4) Remove the optical unit (4).



EFF :

ALL  33-43-11

Page 402
Aug 01/06
 
IAC 
Runway Turnoff Light
Figure 401/TASK 33-43-11-991-001



EFF :

ALL  33-43-11

Page 403
Feb 01/96
 
IAC 
TASK 33-43-11-400-001

Installation of the Runway Turnoff Light (3LC1, 3LC2)

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R Material No. 05-002 USA MIL-PRF-8116


PUTTY, ZINC CHROMATE GENERAL PURPOSE (Ref. 20-31-00)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-43-00-710-001 Operational Test of the Runway Turnoff Lights


33-43-11-730-001 Adjustment of the Runway Turnoff Light (3LC1, 3LC2)

3. __________
Job Set-up

Subtask 33-43-11-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 3LC1
122VU LIGHTING/EXT LT/RWY TURN OFF/L 1LC1 W06
FOR 3LC2
122VU LIGHTING/EXT LT/RWY TURN OFF/R 1LC2 W05



EFF :

ALL  33-43-11

Page 404
Feb 01/08
 
IAC 
4. Procedure
_________

**ON A/C 001-012, 014-099,

Subtask 33-43-11-420-050

A. Installation of the Light

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Make sure that the filament of the lamp and the lens are in the
correct condition.

(4) Remove the blanking cap from the electrical connector (5) and from
the support.

(5) Make sure that the electrical connector (5) is in the correct
condition.

(6) Connect the electrical connector (5) to its support.

(7) Put the optical unit (4) in position on its support (3). Hold it in
this position.

(8) Apply SPECIAL MATERIALS (Material No. 05-002) to the screws (1).

(9) Install the optical unit (4) with the two screws (1) and the washers
(2).

(10) Adjust the turnoff light (Ref. TASK 33-43-11-730-001).

**ON A/C 101-199, 901-999,

Subtask 33-43-11-420-050-A

A. Installation of the Light

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Make sure that the filament of the lamp and the lens are in the
correct condition.



EFF :

ALL  33-43-11

Page 405
Feb 01/08
R  
IAC 
(4) Remove the blanking cap from the electrical connector (5) and from
the support.

(5) Make sure that the electrical connector (5) is in the correct
condition.

(6) Connect the electrical connector (5) to its support.

(7) Put the optical unit (4) in position on its support (3). Hold it in
this position.

(8) Apply SPECIAL MATERIALS (Material No. 05-002) to the screws (1).

(9) Install the optical unit (4) with the two screws (1) and the washers
(2).

**ON A/C ALL

Subtask 33-43-11-865-052

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
FOR 3LC1
R 1LC1
FOR 3LC2
R 1LC2

Subtask 33-43-11-710-051

C. Operational Test of the Runway Turnoff Lights

(1) Do the operational test of the runway turnoff lights (Ref. TASK 33-
43-00-710-001).

5. Close-up
________

Subtask 33-43-11-942-050

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-43-11

Page 406
May 01/08
 
IAC 
TASK 33-43-11-960-002

Replacement of the Lamp of the Runway Turnoff Light (3LC1, 3LC2)

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2 MINUTES


_______
AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific Torque Wrench : range 5.00 to 35.00 lbf.in
(0.05 to 0.40 m.daN)

B. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

2 retainer 33-43-11 01 -020


2 retainer 33-43-11 01A-020
3 gasket 33-43-11 01 -030
3 gasket 33-43-11 01A-030



EFF :

ALL  33-43-11

Page 407
May 01/08
R  
IAC 
INTENTIONALLY BLANK


R



 33-43-11

Page 408
Feb 01/08
 
IAC 
R C. Referenced Information

R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------

R 33-43-00-710-001 Operational Test of the Runway Turnoff Lights


R 33-43-11-991-003 Fig. 402

R 3. __________
Job Set-up

R Subtask 33-43-11-865-064

R A. Open, safety and tag this(these) circuit breaker(s):

R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R FOR 3LC1
R 122VU LIGHTING/EXT LT/RWY TURN OFF/L 1LC1 W06
R FOR 3LC2
R 122VU LIGHTING/EXT LT/RWY TURN OFF/R 1LC2 W05

R 4. Procedure
_________

R (Ref. Fig. 402/TASK 33-43-11-991-003)

R Subtask 33-43-11-020-056

R A. Removal of the Lamp

R (1) For the lamp (4):

R (a) Remove the screw (1).

R (b) Remove the retainer (2).

R (c) If the gasket (3) on the retainer (2) is defective, remove and
R discard it.

R (d) Pull the lamp (4) away from the support (6) and disconnect the
R two electrical terminals (5).

R (e) Remove the lamp (4).



EFF :

ALL  33-43-11

Page 409
Aug 01/06
 
IAC 
R Lamp of the Runway Turnoff Light
R Figure 402/TASK 33-43-11-991-003- 12 (SHEET 1)



EFF :

ALL  33-43-11

Page 410
Aug 01/06
 
IAC 
R Lamp of the Runway Turnoff Light
R Figure 402/TASK 33-43-11-991-003- 22 (SHEET 2)



EFF :

ALL  33-43-11

Page 411
Aug 01/06
 
IAC 
R (2) For the lamp (4) (alternate configuration):

R (a) Remove the screw (8), the washer (7) and the insulating washer
R (9).

R (b) Remove the retainer (2).

R (c) Pull the lamp (4) away from the support (6).

R (d) Disconnect the two electrical terminals (5).

R (e) Remove the lamp (4).

R (f) If the gasket (3) on the support (6) is defective, remove and
R discard it.

R Subtask 33-43-11-420-056

R B. Installation of the Lamp

R (1) For the lamp (4):

R (a) Clean the component interface and/or the adjacent area.

R (b) Connect the two electrical terminals (5) to the lamp (4) and put
R it in position on its support (6). Hold it in this position.

R (c) If necessary, install a new gasket (3) on the retainer (2).

R (d) Put the retainer (2) in position.

R NOTE : If the retainer is twisted, replace it.


____

R (e) Install the screw (1).

R (f) TORQUE the screw (1) to between 6 and 7 lbf.in (0.06 and 0.07
R m.daN).

R (2) For the lamp (4) (alternate configuration):

R (a) Clean the component interface and/or the adjacent area.

R (b) If necessary, install a new gasket (3) on the support (6).

R (c) Connect the two electrical terminals (5) to the lamp (4) and put
R it in position on its support (6). Hold it in this position.



EFF :

ALL  33-43-11

Page 412
Aug 01/06
 
IAC 
(d) Put the retainer (2) in position.

NOTE : If the retainer is twisted, replace it.


____

(e) Install the insulating washer (9), the washer (7), and the screw
(8).

(f) For the GE technology:


R - Tighten the screw (8) by two turns after the screw head is in
R contact with the bracket.

NOTE : Make sure that there are no visual signs of distortion of


____
the retainer (2).

(g) For the SHL technology:


- Put a gage with a thickness of 8 mm (0.3149 in.) +/- 0.2 mm
(0.0078 in.) between the two brackets of the retainer (2).
- Tighten the screw (8) until the two brackets touch the gage
without visual signs of distortion of the retainer (2).
- Remove the gage.

Subtask 33-43-11-865-065

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
FOR 3LC1
- 1LC1.
FOR 3LC2
- 1LC2.

Subtask 33-43-11-710-054

D. Operational Test of the Runway Turnoff Lights

(1) Do the operational test of the runway turnoff lights (Ref. TASK 33-
43-00-710-001).

5. Close-up
________

Subtask 33-43-11-942-054

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-43-11

Page 413
Feb 01/07
 
IAC 
TASK 33-43-11-960-001

Replacement of the Halogen Bulb of the Runway Turnoff Light (3LC1, 3LC2)

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


R No specific soap solution

R B. Consumable Materials

R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------

R Material No. 11-010 USA TT-I-735 GRADE A


R ISOPROPYL ALCOHOL (Ref. 20-31-00)
R Material No. 19-003 USA AMS 3819
R LINT-FREE COTTON CLOTH (Ref. 20-31-00)

R C. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

4 retainer 33-43-11 01 -020


4 retainer 33-43-11 01A-020
8 halogen bulb 33-43-11 01 -060
8 halogen bulb 33-43-11 01A-060



EFF :

ALL  33-43-11

Page 414
May 01/07
 
IAC 
R D. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-43-00-710-001 Operational Test of the Runway Turnoff Lights


33-43-11-991-006 Fig. 403

3. __________
Job Set-up

Subtask 33-43-11-865-062

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 3LC1
122VU LIGHTING/EXT LT/RWY TURN OFF/L 1LC1 W06
FOR 3LC2
122VU LIGHTING/EXT LT/RWY TURN OFF/R 1LC2 W05

4. Procedure
_________

(Ref. Fig. 403/TASK 33-43-11-991-006)

Subtask 33-43-11-020-054

A. Removal of the Halogen Bulb

(1) Remove the screw (2), the washer (3) and the insulating washer (1).

(2) Remove the retainer (4).

(3) Pull the lens (5) away from the support (9).

NOTE : Put an adhesive tape to hold the mirror (10) in position on


____
the support (9).

(4) Remove the two screws (6) and the two washers (7).

(5) Carefully remove the halogen bulb (8).



EFF :

ALL  33-43-11

Page 415
May 01/07
 
IAC 
Replacement of the Halogen Bulb
R Figure 403/TASK 33-43-11-991-006



EFF :

ALL  33-43-11

Page 416
Aug 01/06
 
IAC 
Subtask 33-43-11-420-054

B. Installation of the Halogen Bulb

(1) Carefully put a new halogen bulb (8) in position.

NOTE : Make sure that the pinched seal (11) end points forward.
____

(2) Install the two washers (7) and the two screws (6).

(3) Tighten the two screws (6). Apply one more quarter turn to the two
screws (6) after contact.

(4) Remove the adhesive tape from the mirror (10).

(5) Clean the component interface and/or the adjacent area.

R (6) Clean the surface of the lens (5) with CLEANING AGENTS (Material No.
R 11-010) made moist with warm soap solution.

R (7) Dry the surface of the lens (5) with a clean MISCELLANEOUS (Material
R No. 19-003).

R (8) Put the lens (5) in position on the mirror (10).

R (9) Put the retainer (4) in position.

NOTE : If the retainer (4) is twisted, replace it.


____

R (10) Install the insulating washer (1), the washer (3), and the screw (2).

R (11) Put a gage with a thickness of 8 mm (0.3149 in.) between the two
brackets of the retainer (4).

R (12) Tighten the screw (2) until the two brackets touch the gage without
visual signs of distortion of the retainer (4).

R (13) Remove the gage.

Subtask 33-43-11-865-063

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
FOR 3LC1
- 1LC1.
FOR 3LC2
- 1LC2.



EFF :

ALL  33-43-11

Page 417
May 01/07
 
IAC 
Subtask 33-43-11-710-053

D. Operational Test

(1) Do the operational test of the runway turnoff lights (Ref. TASK 33-
43-00-710-001).

5. Close-up
________

Subtask 33-43-11-942-053

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-43-11

Page 418
May 01/07
R  
IAC 
TASK 33-43-11-960-003

Replacement of the Lens and the mirror of the Runway Turnoff Light (3LC1, 3LC2)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2 MINUTES


_______
AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

4 retainer 33-43-11 01 -020


4 retainer 33-43-11 01A-020
5 lens 33-43-11 01 -050
5 lens 33-43-11 01A-050
R 5 lens 33-43-11 01A-050A
9 halogen bulb 33-43-11 01 -060
9 halogen bulb 33-43-11 01A-060
10 mirror 33-43-11 01 -070
10 mirror 33-43-11 01A-070
12 gasket 33-43-11 01 -060
12 gasket 33-43-11 01A-060



EFF :

ALL  33-43-11

Page 419
May 01/07
 
IAC 
R C. Referenced Information

R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------

R 33-43-00-710-001 Operational Test of the Runway Turnoff Lights


R 33-43-11-991-007 Fig. 404

R 3. __________
Job Set-up

R Subtask 33-43-11-865-066

R A. Open, safety and tag this(these) circuit breaker(s):

R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R FOR 3LC1
R 122VU LIGHTING/EXT LT/RWY TURN OFF/L 1LC1 W06
R FOR 3LC2
R 122VU LIGHTING/EXT LT/RWY TURN OFF/R 1LC2 W05

R 4. Procedure
_________

R (Ref. Fig. 404/TASK 33-43-11-991-007)

R Subtask 33-43-11-020-057

R A. Removal of the Lens and the Mirror

R (1) Remove the screw (2), the washer (3) and the insulating washer (1).

R (2) Remove the retainer (4).

R (3) Pull the lamp away from the support (13).

R (4) Disconnect the two electrical terminals (11).

R (5) Pull the lens (5) away from the mirror (10).

R (6) Remove the two screws (6) and the two washers (7).

R (7) Carefully remove and keep the halogen bulb (9).

R (8) If the gasket (12) on the support (13) is defective, remove and
R discard it.



EFF :

ALL  33-43-11

Page 420
Aug 01/06
 
IAC 
R Lens and Mirror of the Runway Turnoff Light
R Figure 404/TASK 33-43-11-991-007



EFF :

ALL  33-43-11

Page 421
Aug 01/06
 
IAC 
R Subtask 33-43-11-420-057

R B. Installation of the Lens and the Mirror

R (1) Carefully put the halogen bulb (9) in position on a new mirror (10).

R NOTE : If the halogen bulb is damaged, replace it.


____

R NOTE : Make sure that the pinched seal (8) end points forward.
____

R (2) Install the two washers (7) and the two screws (6).

R (3) Tighten the two screws (6). Tighten them one more quarter turn after
R contact.

R (4) Install a new gasket (12) on the support (13).

R (5) Put a new lens (5) in position on a new mirror (10) with the halogen
R bulb installed.

R (6) Put the lamp in position on the support (13).

R (7) Put the retainer (4) in position.

R NOTE : If the retainer (4) is twisted, replace it.


____

R (8) Install the insulating washer (1), the washer (3), and the screw (2).

R (9) Put a gage with a thickness of 8 mm (0.3149 in.) between the two
R brackets of the retainer (4).

R (10) Tighten the screw (2) until the two brackets touch the gage without
R visual signs of distortion of the retainer (4).

R (11) Remove the gage.

R Subtask 33-43-11-865-067

R C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
R breaker(s):
R FOR 3LC1
R - 1LC1.
R FOR 3LC2
R - 1LC2.



EFF :

ALL  33-43-11

Page 422
Aug 01/06
 
IAC 
R Subtask 33-43-11-710-055

R D. Operational Test

R (1) Do the operational test of the runway turnoff lights (Ref. TASK 33-
R 43-00-710-001).

R 5. Close-up
________

R Subtask 33-43-11-942-055

R A. Make sure that the work area is clean and clear of tool(s) and other
R items.



EFF :

ALL  33-43-11

Page 423
Aug 01/06
 
IAC 
LIGHT - RUNWAY TURNOFF (3LC1,3LC2) - ADJUSTMENT/TEST
____________________________________________________

TASK 33-43-11-730-001

Adjustment of the Runway Turnoff Light (3LC1, 3LC2)

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2 MINUTES


_______
AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

R CAUTION : MAKE SURE THAT THE ITEMS IN THE FIXTURES, TOOLS, TEST AND SUPPORT
_______
R EQUIPMENT PARAGRAPH ARE APPLICABLE TO YOUR AIRCRAFT (THIS LIST IS
R NOT CUSTOMIZED). REFER TO THE APPLICABLE SUBTASKS.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific strap
No specific Torque Wrench : range 0.00 to 1.20 m.daN
(0.00 to 9.00 lbf.ft)
98D33403502000 1 ADJUSTING TOOL - TURN OFF LIGHT

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

08-22-00-200-001 Precise Leveling


33-43-11-991-004 Fig. 501


R

EFF :

001-012, 014-099,  33-43-11

Page 501
May 01/06
 
IAC 
3. __________
Job Set-up

Subtask 33-43-11-865-058

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 3LC1
122VU LIGHTING/EXT LT/RWY TURN OFF/L 1LC1 W06
FOR 3LC2
122VU LIGHTING/EXT LT/RWY TURN OFF/R 1LC2 W05

Subtask 33-43-11-860-050

B. Aircraft Maintenance Configuration

(1) Make sure that the aircraft fuselage is in the horizontal position.

(2) If not, do the precise leveling (Ref. TASK 08-22-00-200-001).

4. Procedure
_________

(Ref. Fig. 501/TASK 33-43-11-991-004)

Subtask 33-43-11-820-050

A. Adjustment of the Turnoff Light with the Tool

(1) Install the ADJUSTING TOOL - TURN OFF LIGHT (98D33403502000) (3) on
the light.

(2) Set the clinometer to an angle of 0 deg. +/-2 minutes. Put it against
the tool (3) to make sure that the installation is horizontal.

(3) Adjust the tool (3) if necessary and tighten the nuts (2).

(4) Angular adjustment of the turnoff light

(a) Set the clinometer to an angle of 2 deg. 30 minutes +/-2 minutes


(nose down).

(b) Put the clinometer on the applicable zone of the tool,


perpendicular to the light and attach it with the strap.


R

EFF :

001-012, 014-099,  33-43-11

Page 502
May 01/06
 
IAC 
Adjustment of the Runway Turnoff Light
Figure 501/TASK 33-43-11-991-004


R

EFF :

001-012, 014-099,  33-43-11

Page 503
May 01/06
 
IAC 
(c) Loosen the nuts (1), move the light to get the angle of 2 deg. 30
minutes +/-2 minutes.

(d) TORQUE the nuts (1) to between 0.6 and 0.75 m.daN (53.09 and
66.37 lbf.in) and make sure that the adjustment is correct.

(e) Remove the clinometer and the ADJUSTING TOOL - TURN OFF LIGHT
(98D33403502000).

5. Close-up
________

Subtask 33-43-11-865-059

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LC1, 1LC2


R

EFF :

001-012, 014-099,  33-43-11

Page 504
May 01/06
 
IAC 
TASK 33-43-11-730-001- 01

Adjustment of the Runway Turnoff Light (3CL1, 3CL2) - Alternative Procedure

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2 MINUTES


_______
AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific screen
No specific Torque Wrench : range 0.00 to 1.20 m.daN
(0.00 to 9.00 lbf.ft)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

08-22-00-200-001 Precise Leveling


AMM 11-21-08 P.Block 001 LEVELING AND WEIGHING
33-43-11-991-005 Fig. 502


R

EFF :

001-012, 014-099,  33-43-11

Page 505
May 01/06
 
IAC 
3. __________
Job Set-up

Subtask 33-43-11-865-060

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 3LC1
122VU LIGHTING/EXT LT/RWY TURN OFF/L 1LC1 W06
FOR 3LC2
122VU LIGHTING/EXT LT/RWY TURN OFF/R 1LC2 W05

Subtask 33-43-11-860-051

B. Aircraft Maintenance Configuration

(1) Make sure that the aircraft is on a horizontal surface.

(2) Do a precise leveling (Ref. TASK 08-22-00-200-001).

4. Procedure
_________

(Ref. Fig. 502/TASK 33-43-11-991-005)

Subtask 33-43-11-820-051

A. Adjustment of the Runway Turnoff Light

(1) Install the screen (2) in front of the aircraft. The distance between
the screen and the nose landing gear must be 10 m (32.80 ft.).

(2) Turn the screen (2) 45 deg. away from the aircraft axis (with the
nose landing gear as a rotation axis).

NOTE : The screen can be a wooden board with a minimum height of 3 m


____
(9.84 ft.) and a minimum width of 2 m (6.56 ft.).

(3) Angular adjustment of the runway turn off light

(a) Measure the distance X between the aircraft centerline and the
ground. To do this, measure the distance between one of the
leveling triangles and the ground (Ref. AMM 11-21-08 P.Block
001).


R

EFF :

001-012, 014-099,  33-43-11

Page 506
May 01/06
 
IAC 
NOTE : To get an accurate distance, the aircraft must be on a
____
horizontal surface.

(b) Subtract the vertical value 3.091 m (10.14 ft.) from the distance
X. This gives you the value Y which is the distance between
the ground and the target on the screen. You must adjust the
light beam to the center of the target.

(c) Loosen the nuts (1), and move the light to adjust the light beam
on the target.

(d) TORQUE the nuts (1) to between 0.6 and 0.75 m.daN (53.09 and
66.37 lbf.in) and make sure that the adjustment is correct.

5. Close-up
________

Subtask 33-43-11-865-061

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LC1, 1LC2


R

EFF :

001-012, 014-099,  33-43-11

Page 507
May 01/06
 
IAC 
Adjustment of the Runway Turnoff Light - Alternative Procedure
Figure 502/TASK 33-43-11-991-005- 12 (SHEET 1)


R

EFF :

001-012, 014-099,  33-43-11

Page 508
May 01/06
 
IAC 
Adjustment of the Runway Turnoff Light - Alternative Procedure
Figure 502/TASK 33-43-11-991-005- 22 (SHEET 2)


R

EFF :

001-012, 014-099,  33-43-11

Page 509
May 01/06
 
IAC 
TAXI AND TAKE OFF LIGHTS - DESCRIPTION AND OPERATION
____________________________________________________

1. _______
General
The taxi and take-off light system illuminates the runway during the taxi
and the take off phase. Two light units provide the lighting. They are
installed on the nose landing gear.

2. Component
__________________
Location
(Ref. Fig. 001)

-------------------------------------------------------------------------------
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
4LR SW-EXT LT/NOSE 25VU 210
5LR RELAY-PWR SPLY, TO LT 107VU 126
6LR RELAY-PWR SPLY, TAXI LT 107VU 126
7LR LT-TAKE OFF 711 33-46-11
8LR LT-TAXI 711 33-46-12

3. __________________
System Description
R
(Ref. Fig. 002)
The taxi and take-off light system consists of:
R - a single filament light (or halogen lamp in alternate solution) 8LR, rated
R at 450 Watts, installed on the nose landing gear in a fixed position
- a transformer, to produce rated operating voltage
R - a single filament light (or halogen lamp in alternate solution) 7LR, rated
R at 600 Watts, installed on the nose landing gear in a fixed position
- a transformer, to produce rated operating voltage
- two power supply relays 5LR for the takeoff and 6LR for the taxi light
- a switch 4LR, on the cockpit overhead panel.
The 115 VAC busbar 204XP supplies power to the taxi light through the
circuit breaker 1LR and relay 6LR. The 115 VAC busbar 103XP supplies power
to the take off light through the circuit breaker 3LR and relay 5LR. The 28
VDC busbar 202PP supplies power to the switch 4LR through the circuit
breaker 2LR. The landing-gear computer supplies the power supply relays 5LR
and 6LR with a ground signal when the nose landing gear is downlocked.
R

4. Operation/Control
________________________________
and Indicating
(Ref. Fig. 002)
With energized busbars and closed circuit breakers, 115 VAC is supplied to
the contacts of the power relays. The control switch is supplied with 28
VDC. When the nose landing gear is downlocked, the power supply relays get a
ground signal. When the control switch 4LR is in the TAXI position, the
relay 6LR energizes and the taxi light 8LR comes on.



EFF :

ALL  33-46-00

Page 1
May 01/06
 
IAC 
R Taxi and Take off Lights - Component Location
Figure 001



EFF :

ALL  33-46-00

Page 2
May 01/06
 
IAC 
Taxi and Take off Lights - Schematic
Figure 002



EFF :

ALL  33-46-00

Page 3
Feb 01/96
 
IAC 
With the switch 4LR in the T.O position, the relay 5LR energizes and
continues to energize the relay 6LR. The taxi light 8LR and the take off
light 7LR come on.
When the nose landing gear is unlocked, the ground signal for the power
supply relays is removed.
The take off light and the taxi light go off.
You can also switch off the lights with the switch 4LR in the OFF position.



EFF :

ALL  33-46-00

Page 4
May 01/06
R  
IAC 
TAXI AND TAKE OFF LIGHTS - DEACTIVATION/REACTIVATION
____________________________________________________

TASK 33-46-00-040-001

Deactivation of the Taxi Light (8LR)

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

1. __________________
Reason for the Job

Refer to the CDL TASK: 33-2


Taxi Light Lamp

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific soap solution

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 05-065 C Z-24.380


EROSION PROTECTIVE TAPE (Ref. 20-31-00)
R Material No. 08-052 USA AMS-T-23397 AND/OR L-T-80B
R SELF ADHESIVEALUMINIUM TAPE (Ref. 20-31-00)
Material No. 19-003 USA AMS 3819
LINT-FREE COTTON CLOTH (Ref. 20-31-00)

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-46-12-000-001 Removal of the Taxi Light (8LR)


33-46-12-400-001 Installation of the Taxi Light (8LR)



EFF :

ALL  33-46-00

Page 401
Nov 01/07
 
IAC 
3. __________
Job Set-up

Subtask 33-46-00-941-050

A. Safety Precautions

(1) Put a warning notice on the EXT LT section of the panel 25VU to tell
persons not to operate the taxi light.

Subtask 33-46-00-865-051

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TAXI 1LR W08

4. Procedure
_________

Subtask 33-46-00-040-050

A. Deactivation of the Taxi Light

CAUTION : IF THE LAMP IS REMOVED, SAFETY THE WIRES WITH HIGH-SPEED TAPE.
_______

(1) You must remove (Ref. TASK 33-46-12-000-001) or replace (Ref. TASK
33-46-12-000-001) and (Ref. TASK 33-46-12-400-001) the taxi light if
there are these two conditions:
- if there are cracks on the front face, and
- if there is movement of the parts of the front glass (the
supporting structure does not hold them tightly).

(2) You can do an alternative repair as follows if there are these two
conditions:
- if there are cracks on the front face, and
- if there is no movement of the parts of the front glass.

(a) Clean the surface of the taxi light lens with MISCELLANEOUS
(Material No. 19-003) made moist with warm soap solution.

(b) Dry the surface of the taxi light lens with a clean MISCELLANEOUS
(Material No. 19-003).



EFF :

ALL  33-46-00

Page 402
Nov 01/07
R  
IAC 
R (c) Apply SPECIAL MATERIALS (Material No. 05-065) or BONDING AND
R ADHESIVE COMPOUNDS (Material No. 08-052) to cover the crack(s).

NOTE : Make sure that the tape is correctly installed and has no
____
bubbles, wrinkles or tears in it.

(3) If it is not necessary to replace the taxi light, write in the


aircraft technical log that the taxi light is damaged.

5. Close-up
________

Subtask 33-46-00-865-052

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged
1LR

Subtask 33-46-00-942-053

B. Put the aircraft back to its initial configuration.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the warning notice(s).



EFF :

ALL  33-46-00

Page 403
Nov 01/07
 
IAC 
TASK 33-46-00-440-001

Reactivation of the Taxi Light (8LR)

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

1. __________________
Reason for the Job

Refer to the CDL TASK: 33-2


Taxi Light Lamp

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-46-12-000-001 Removal of the Taxi Light (8LR)


33-46-12-400-001 Installation of the Taxi Light (8LR)

3. __________
Job Set-up

Subtask 33-46-00-941-051

A. Safety Precautions

(1) Put a warning notice on the EXT LT section of the panel 25VU to tell
persons not to operate the taxi light.



EFF :

ALL  33-46-00

Page 404
May 01/04
R  
IAC 
Subtask 33-46-00-865-053

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TAXI 1LR W08

4. Procedure
_________

Subtask 33-46-00-440-050

A. Reactivation of the Taxi Light

(1) Replace the taxi light (Ref. TASK 33-46-12-000-001) and (Ref. TASK
33-46-12-400-001).

5. Close-up
________

Subtask 33-46-00-865-054

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LR

Subtask 33-46-00-942-052

B. Put the aircraft back to its initial configuration.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the warning notice(s).



EFF :

ALL  33-46-00

Page 405
Nov 01/07
R  
IAC 
TASK 33-46-00-040-002

Deactivation of the Take Off Light (7LR)

1. __________________
Reason for the Job

Refer to the CDL TASK: 33-9


Take Off Light

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific soap solution

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 05-065 C Z-24.380


EROSION PROTECTIVE TAPE (Ref. 20-31-00)
R Material No. 08-052 USA AMS-T-23397 AND/OR L-T-80B
R SELF ADHESIVEALUMINIUM TAPE (Ref. 20-31-00)
Material No. 19-003 USA AMS 3819
LINT-FREE COTTON CLOTH (Ref. 20-31-00)

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-46-11-000-001 Removal of the Take Off Light (7LR)


33-46-11-400-001 Installation of the Take Off Light (7LR)



EFF :

ALL  33-46-00

Page 406
Nov 01/07
 
IAC 
3. __________
Job Set-up

Subtask 33-46-00-941-052

A. Safety Precautions

(1) Put a warning notice in position on the EXT LT section of the


overhead panel 25VU to tell persons not to operate the take off
light.

Subtask 33-46-00-865-055

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TO 3LR W07

4. Procedure
_________

Subtask 33-46-00-040-051

A. Deactivation of the Take Off Light

CAUTION : IF THE LAMP IS REMOVED, SAFETY THE WIRES WITH HIGH-SPEED TAPE.
_______

(1) You must remove (Ref. TASK 33-46-11-000-001) or replace (Ref. TASK
33-46-11-000-001) and (Ref. TASK 33-46-11-400-001) the take off light
if there are these two conditions:
- if there are cracks on the front face, and
- if there is movement of the parts of the front glass (the
supporting structure does not hold them tightly).

(2) If you do not remove or replace the cracked take-off light, you can
do an alternative repair as follows:

(a) Clean the surface of the take-off light lens with MISCELLANEOUS
(Material No. 19-003) made moist with warm soap solution.

(b) Dry the surface of the take-off light lens with a clean
MISCELLANEOUS (Material No. 19-003).



EFF :

ALL  33-46-00

Page 407
Aug 01/07
R  
IAC 
R (c) Apply SPECIAL MATERIALS (Material No. 05-065) or BONDING AND
R ADHESIVE COMPOUNDS (Material No. 08-052) to cover the crack(s).

NOTE : Make sure that the tape is correctly installed and has no
____
bubbles, wrinkles or tears in it.

(3) If it is not necessary to replace the take off light, write in the
aircraft technical log that the take off light is damaged.

5. Close-up
________

Subtask 33-46-00-865-056

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged
3LR

Subtask 33-46-00-942-054

B. Put the aircraft back to its initial configuration.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the warning notice(s).



EFF :

ALL  33-46-00

Page 408
Nov 01/07
 
IAC 
TASK 33-46-00-440-002

Reactivation of the Take Off Light (7LR)

1. __________________
Reason for the Job

Refer to the CDL TASK: 33-9


Take Off Light

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-46-11-000-001 Removal of the Take Off Light (7LR)


33-46-11-400-001 Installation of the Take Off Light (7LR)

3. __________
Job Set-up

Subtask 33-46-00-941-053

A. Safety Precautions

(1) Put a warning notice in position on the EXT LT section of the


overhead panel 25VU to tell persons not to operate the take off
light.

Subtask 33-46-00-865-057

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TO 3LR W07



EFF :

ALL  33-46-00

Page 409
Aug 01/06
 
IAC 
R

4. Procedure
_________

Subtask 33-46-00-440-051

A. Reactivation of the Take Off Light

(1) Replace the take off light (Ref. TASK 33-46-11-000-001) and
(Ref. TASK 33-46-11-400-001).

5. Close-up
________

Subtask 33-46-00-865-058

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
3LR

Subtask 33-46-00-942-055

B. Put the aircraft back to its initial configuration.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the warning notice(s).



EFF :

ALL  33-46-00

Page 410
Aug 01/06
 
IAC 
TAXI AND TAKE OFF LIGHTS - ADJUSTMENT/TEST
__________________________________________

TASK 33-46-00-710-001

Operational Test of the Taxi and Take Off Lights

1. __________________
Reason for the Job

Make sure that the taxi and take off lights operate correctly.

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-46-00-861-051

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-46-00-865-050

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/CTL 2LR W09
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TAXI 1LR W08
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TO 3LR W07



EFF :

ALL  33-46-00

Page 501
Aug 01/06
 
IAC 
R

4. Procedure
_________

Subtask 33-46-00-710-050

A. Operational test of Lights

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the panel 25VU: On the nose landing gear:


- set the NOSE selector switch to - the taxi light comes on,
TAXI,

- set the NOSE selector switch to - the taxi and take off lights come on,
TO,

- set the NOSE selector switch to - the taxi and take off lights go off.
OFF.

5. Close-up
________

Subtask 33-46-00-862-051

A. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-46-00

Page 502
Aug 01/06
 
IAC 
R **ON A/C 001-012, 014-099,

TASK 33-46-00-730-001

Adjustment of the Light Mounts

R CAUTION : MAKE SURE THAT THE ITEMS IN THE FIXTURES, TOOLS, TEST AND SUPPORT
_______
R EQUIPMENT PARAGRAPH ARE APPLICABLE TO YOUR AIRCRAFT (THIS LIST IS
R NOT CUSTOMIZED). REFER TO THE APPLICABLE SUBTASKS.

1. __________________
Reason for the Job

To make sure that the light mounts are parallel to the aircraft centerline.

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

98D33403503000 1 ADJUSTING TOOL - TAKE-OFF/TAXI LIGHTS

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

32-22-00-010-001 Nose Gear Doors - Ground Doors Opening


32-22-00-410-001 Nose Gear Doors - Ground Doors Closing
33-46-11-000-001 Removal of the Take Off Light (7LR)
33-46-11-400-001 Installation of the Take Off Light (7LR)
33-46-12-000-001 Removal of the Taxi Light (8LR)
33-46-12-400-001 Installation of the Taxi Light (8LR)
33-46-00-991-001 Fig. 501

3. __________
Job Set-up

Subtask 33-46-00-010-050

R A. Open the Main Doors of the Nose Gear (Ref. TASK 32-22-00-010-001).


R

EFF :

001-012, 014-099,  33-46-00

Page 503
May 01/06
 
IAC 
4. Procedure
_________

Subtask 33-46-00-820-050

A. Adjustment of the Light Mounts


(Ref. Fig. 501/TASK 33-46-00-991-001)

(1) Remove the taxi light (8LR) (Ref. TASK 33-46-12-000-001) and the take
off light (7LR) (Ref. TASK 33-46-11-000-001).

(2) Loosen the 3 screws (1) of the two light mounts.

(3) Install the tool ADJUSTING TOOL - TAKE-OFF/TAXI LIGHTS


(98D33403503000)
- put the sleeve (3) in position on the upper fork of the right mount
and lock it with the needle (2),
- put the tooling assembly (4) (slide rod and sleeve) in position on
the upper fork of the left mount and lock it with the needle (2),
- put the index (5) against the vertical web of the mount.

(4) Move the rod of the tooling assembly (4) laterally. The rod must
slide freely from the left sleeve to the right sleeve.

(5) Tighten the 3 screws (1) on the two light mounts.

(6) Make sure that you can turn the rod freely in the two sleeves.

(7) Remove the right and left needles (2), then remove the sleeve (3) and
tooling assembly (4) .

(8) Install the taxi light (8LR) (Ref. TASK 33-46-12-400-001) and the
take off light (7LR) (Ref. TASK 33-46-11-400-001).

5. Close-up
________

Subtask 33-46-00-410-050

A. Close the Main Doors of the Nose Gear (Ref. TASK 32-22-00-410-001).


R

EFF :

001-012, 014-099,  33-46-00

Page 504
May 01/06
 
IAC 
Adjustment of the Taxi Light and Take Off Light Mounts
Figure 501/TASK 33-46-00-991-001


R

EFF :

001-012, 014-099,  33-46-00

Page 505
May 01/06
 
IAC 
LIGHT - TAKE OFF (7LR) - REMOVAL/INSTALLATION
_____________________________________________

TASK 33-46-11-000-001

Removal of the Take Off Light (7LR)

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2 MINUTES


_______
AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-099,

33-46-11-991-001 Fig. 401

R **ON A/C 101-199, 901-999,

33-46-11-991-001-A Fig. 401A



EFF :

ALL  33-46-11

Page 401
Feb 01/07
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-46-11-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TO 3LR W07

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-46-11-991-001)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-46-11-991-001-A)

**ON A/C ALL

Subtask 33-46-11-020-050

A. Removal of the Take Off Light

(1) Disconnect the electrical connector (12) from the socket (11).

(2) Put the blanking caps on the disconnected electrical connector (12)
and the socket (11).

(3) Remove the nut (6), the washer (7), the screw (9) and the washer (8).

(4) Remove the nuts (5), the washers (4), the screws (1) and the washers
(2). During this operation, hold the light (10).

(5) Remove the light (10) from its support (3).



EFF :

ALL  33-46-11

Page 402
Feb 01/07
 
IAC 
Take Off Light
Figure 401/TASK 33-46-11-991-001


R

EFF :

001-012, 014-099,  33-46-11

Page 403
May 01/06
 
IAC 
Take Off Light
Figure 401A/TASK 33-46-11-991-001-A


R

EFF :

101-199, 901-999,  33-46-11

Page 404
Feb 01/07
 
IAC 
TASK 33-46-11-400-001

Installation of the Take Off Light (7LR)

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R Material No. 05-002 USA MIL-PRF-8116


PUTTY, ZINC CHROMATE GENERAL PURPOSE (Ref. 20-31-00)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-46-00-710-001 Operational Test of the Taxi and Take Off Lights


33-46-11-730-001 Adjustment of the Take Off Light (7LR)

**ON A/C 001-012, 014-099,

33-46-11-991-001 Fig. 401

**ON A/C 101-199, 901-999,

33-46-11-991-001-A Fig. 401A



EFF :

ALL  33-46-11

Page 405
Feb 01/08
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-46-11-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TO 3LR W07

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-46-11-991-001)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-46-11-991-001-A)

**ON A/C 001-012, 014-099,

Subtask 33-46-11-420-050

A. Installation of the Take Off Light

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Make sure that the filament of the bulb and the lens of the optical
unit are in the correct condition.

(4) Make sure that the clamp is correctly installed.

(5) Put the light (10) on its support (3).

(6) Apply SPECIAL MATERIALS (Material No. 05-002) to the screws (1) and
(9).



EFF :

ALL  33-46-11

Page 406
Feb 01/07
 
IAC 
(7) Install the light (10) in the lower fork of the support (3).

(8) Put the washer (8) on the screw (9).

(9) Install the screws in the support (3).

(10) Install the washer (7) and tighten the nut (6).

(11) Turn the light to the upper forks.

(12) Put the washers (2) on the screws (1).

(13) Install the screws in the support (3).

(14) Install the washer (4) and tighten the nut (5).

(15) Adjust the take off light (Ref. TASK 33-46-11-730-001).

(16) Remove the blanking caps from the electrical connector (12) and the
socket (11).

(17) Make sure that the electrical connector (12) and the socket (11) are
in the correct condition.

(18) Connect the electrical connector (12) to the socket (11) and lock it.

R **ON A/C 101-199, 901-999,

Subtask 33-46-11-420-050-A

A. Installation of the Take Off Light

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Make sure that the filament of the bulb and the lens of the optical
unit are in the correct condition.

(4) Make sure that the clamp is correctly installed.

(5) Put the light (10) on its support (3).

(6) Apply SPECIAL MATERIALS (Material No. 05-002) to the screws (1) and
(9).



EFF :

ALL  33-46-11

Page 407
Feb 01/07
 
IAC 
(7) Install the light (10) in the lower fork of the support (3).

(8) Put the washer (8) on the screw (9).

(9) Install the screws in the support (3).

(10) Install the washer (7) and tighten the nut (6).

(11) Turn the light to the upper forks.

(12) Put the washers (2) on the screws (1).

(13) Install the screws in the support (3).

(14) Install the washer (4) and tighten the nut (5).

(15) Remove the blanking caps from the electrical connector (12) and the
socket (11).

(16) Make sure that the electrical connector (12) and the socket (11) are
in the correct condition.

(17) Connect the electrical connector (12) to the socket (11) and lock it.

**ON A/C ALL

Subtask 33-46-11-865-052

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
3LR

Subtask 33-46-11-710-051

C. Operational Test of the Light

(1) Do the operational test of the Take off Light (Ref. TASK 33-46-00-
710-001).

5. Close-up
________

Subtask 33-46-11-942-050

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-46-11

Page 408
Feb 01/07
R  
IAC 
TASK 33-46-11-960-001

Replacement of the Lamp in the Take Off Light (7LR)

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2 MINUTES


_______
AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific Torque Wrench : range 5.00 to 35.00 lbf.in
(0.05 to 0.40 m.daN)

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R Material No. 08-004 AIB AIMS-04-05-003


ADHESIVE SEALANT (Ref. 20-31-00)



EFF :

ALL  33-46-11

Page 409
Feb 01/07
 
IAC 
C. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

2 retainer 33-46-11 01 -010


2 retainer 33-46-11 01 -020
2 retainer 33-46-11 01A-010
2 retainer 33-46-11 01A-020
3 gasket 33-46-11 01 -030
3 lamp 33-46-11 01 -050
3 gasket 33-46-11 01A-030
3 lamp 33-46-11 01A-050
4 lamp 33-46-11 01 -040
4 lamp 33-46-11 01A-040
4 gasket 33-46-11 01A-110
7 gasket 33-46-11 01 -100
7 gasket 33-46-11 01A-100

D. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-46-00-710-001 Operational Test of the Taxi and Take Off Lights


33-46-11-991-003 Fig. 402

3. __________
Job Set-up

Subtask 33-46-11-865-058

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TO 3LR W07



EFF :

ALL  33-46-11

Page 410
Feb 01/07
R  
IAC 
INTENTIONALLY BLANK


R



 33-46-11

Page 411
Feb 01/07
 
IAC 
INTENTIONALLY BLANK


R



 33-46-11

Page 412
Feb 01/07
 
IAC 
R

4. Procedure
_________

(Ref. Fig. 402/TASK 33-46-11-991-003)

Subtask 33-46-11-020-054

R A. Removal of the Lamp

CAUTION : MAKE MATCH MARKS ON ALL THE ELECTRICAL WIRES BEFORE YOU
_______
DISCONNECT THEM. INCORRECT CONNECTION OF WIRES WILL CAUSE
DAMAGE TO EQUIPMENT.

(1) For the lamp (4):

(a) Remove the screw (1).

(b) Remove the retainer (2).

(c) Remove the gasket (3) attached to the retainer (2) if it is


defective.

(d) Pull the lamp (4) away from the support (6) and disconnect the
two electrical terminals (5).

(e) Remove the lamp (4).

(f) If the gasket (7) on the support (6) is defective, remove and
discard it.

(2) For the lamp (3) (alternate configuration):

R (a) Remove the screw (1), the washer (7) and the insulating washer
R (8).

(b) Remove the retainer (2).

R (c) Pull the lamp (3) away from the support (6) and disconnect the
R three electrical terminals (5).

R NOTE : Before disconnection, attach the two electrical terminals


____
R that are connected to the same terminal stud together with
R tape.

(d) Remove the lamp (3).



EFF :

ALL  33-46-11

Page 413
Aug 01/06
 
IAC 
R Lamp of the Take off Light
R Figure 402/TASK 33-46-11-991-003- 12 (SHEET 1)



EFF :

ALL  33-46-11

Page 414
Aug 01/06
 
IAC 
R Lamp of the Take off Light
R Figure 402/TASK 33-46-11-991-003- 22 (SHEET 2)



EFF :

ALL  33-46-11

Page 415
Aug 01/06
 
IAC 
(e) If the gasket (4) on the support (6) is defective, remove and
discard it.

Subtask 33-46-11-420-054

R B. Installation of the Lamp

(1) For the lamp (4):

R (a) If necessary, install and bond with BONDING AND ADHESIVE


R COMPOUNDS (Material No. 08-004) a new gasket (7) on the support
R (6).
R

R (b) Connect the two electrical terminals (5) to a new lamp (4) and
R install it in position on its support (6). Hold it in this
position.

R (c) If necessary, install and bond with BONDING AND ADHESIVE


R COMPOUNDS (Material No. 08-004) a new gasket (3) on the retainer
(2).

CAUTION : MAKE SURE THAT THE GASKET IS IN THE CORRECT POSITION.


_______
IF NOT, YOU CAN DECREASE THE LIFE OF THE LAMP.

(d) Put the retainer (2) in position.

(e) Install the screw (1).

(f) TORQUE the screw (1) to between 6 and 7 lbf.in (0.06 and 0.07
m.daN).

(2) For the lamp (3) (alternate configuration):

R (a) Clean the component interface and/or the adjacent area.

R (b) If necessary, install a new gasket (4) on the support (6).


R

R (c) Connect the three electrical terminals (5) to a new lamp (3) and
R put it in position on its support (6). Hold it in this position.

CAUTION : MAKE SURE THAT THE GASKET IS IN THE CORRECT POSITION.


_______
IF NOT, YOU CAN DECREASE THE LIFE OF THE LAMP.

R NOTE : After connection, remove the tape that attaches the two
____
R electrical terminals together.



EFF :

ALL  33-46-11

Page 416
Aug 01/06
 
IAC 
(d) Put the retainer (2) in position.

NOTE : If the retainer (2) is twisted, replace it.


____

(e) Install the insulating washer (8), the washer (7) and the screw
(1).

(f) For the GE technology:


R - Tighten the screw (1) by two turns after the screw head is in
R contact with the bracket.

NOTE : Make sure that there are no visual signs of distortion of


____
the retainer (2).

(g) For the SHL technology:


- Put a gage with a thickness of 11 mm (0.4330 in.) between the
two brackets of the retainer (2).
- Tighten the screw (1) until the two brackets touch the gage
without visual signs of distortion of the retainer (2).
- Remove the gage.

Subtask 33-46-11-865-059

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
3LR

Subtask 33-46-11-710-053

D. Operationnal test of the Light

(1) Do the operational test of the Take off Light (Ref. TASK 33-46-00-
710-001).

5. Close-up
________

Subtask 33-46-11-942-053

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-46-11

Page 417
Feb 01/07
 
IAC 
TASK 33-46-11-960-002

Replacement of the Halogen Bulb of the Take Off Light (7LR)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


R No specific soap solution

R B. Consumable Materials

R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------

R Material No. 11-010 USA TT-I-735 GRADE A


R ISOPROPYL ALCOHOL (Ref. 20-31-00)
R Material No. 19-003 USA AMS 3819
R LINT-FREE COTTON CLOTH (Ref. 20-31-00)

R C. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

2 retainer 33-46-11 01 -010


2 retainer 33-46-11 01A-010
6 halogen bulb 33-43-11 01 -070
6 halogen bulb 33-43-11 01A-070



EFF :

ALL  33-46-11

Page 418
May 01/07
 
IAC 
R D. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-46-00-710-001 Operational Test of the Taxi and Take Off Lights


33-46-11-991-006 Fig. 403

3. __________
Job Set-up

Subtask 33-46-11-865-066

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TO 3LR W07

4. Procedure
_________

(Ref. Fig. 403/TASK 33-46-11-991-006)

Subtask 33-46-11-020-055

A. Removal of the Halogen Bulb

(1) Remove the screw (1), the washer (10) and the insulating washer (11).

(2) Remove the retainer (2).

(3) Pull the lens (3) away from the support (7).

NOTE : Put an adhesive tape to hold the mirror (8) in position on the
____
support (7).

(4) Remove the two screws (4) and the two washers (5).

(5) Carefully remove the halogen bulb (6).



EFF :

ALL  33-46-11

Page 419
May 01/07
 
IAC 
R Replacement of the Halogen Bulb
Figure 403/TASK 33-46-11-991-006



EFF :

ALL  33-46-11

Page 420
Aug 01/06
 
IAC 
Subtask 33-46-11-420-055

B. Installation of the Halogen Bulb

(1) Carefully put a new halogen bulb (6) in position.

NOTE : Make sure that the pinched seal (9) end points forward.
____

(2) Install the two washers (5) and the two screws (4).

(3) Tighten the two screws (4). Apply one more quarter turn to the two
screws (4) after contact.

(4) Remove the adhesive tape from the mirror (8).

(5) Clean the component interface and/or the adjacent area.

R (6) Clean the surface of the lens (3) with CLEANING AGENTS (Material No.
R 11-010) made moist with warm soap solution.

R (7) Dry the surface of the lens (3) with a clean MISCELLANEOUS (Material
R No. 19-003).

R (8) Put the lens (3) in position on the mirror (8).

R (9) Put the retainer (2) in position.

NOTE : If the retainer (2) is twisted, replace it.


____

R (10) Install the insulating washer (11), the washer (10) and the screw
(1).

R (11) Put a gage with a thickness of 11 mm (0.4330 in.) between the


brackets of the retainer (2).

R (12) Tighten the screw (1) until the two brackets touch the gage without
visual signs of distortion of the retainer (2).

R (13) Remove the gage.

Subtask 33-46-11-865-067

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
3LR



EFF :

ALL  33-46-11

Page 421
May 01/07
 
IAC 
Subtask 33-46-11-710-054

D. Operational Test

(1) Do the operational test of the take off light (Ref. TASK 33-46-00-
710-001).

5. Close-up
________

Subtask 33-46-11-942-054

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-46-11

Page 422
May 01/07
R  
IAC 
TASK 33-46-11-960-003

Replacement of the Lens and the Mirror of the Take Off Light (7LR)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

4 retainer 33-43-11 01 -010


4 retainer 33-43-11 01A-010
5 lens 33-43-11 01 -060
5 lens 33-43-11 01A-060
9 halogen bulb 33-43-11 01 -070
9 halogen bulb 33-43-11 01A-070
10 mirror 33-43-11 01 -080
10 mirror 33-43-11 01A-080
12 gasket 33-43-11 01A-100

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-46-00-710-001 Operational Test of the Taxi and Take Off Lights


33-46-11-991-007 Fig. 404



EFF :

ALL  33-46-11

Page 423
May 01/07
R  
IAC 
3. __________
Job Set-up

Subtask 33-46-11-865-068

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TO 3LR W07

4. Procedure
_________

(Ref. Fig. 404/TASK 33-46-11-991-007)

Subtask 33-46-11-020-057

A. Removal of the Lens and the Mirror

(1) Remove the screw (2), the washer (3) and the insulating washer (1).

(2) Remove the retainer (4).

(3) Pull the lamp away from the support (13).

(4) Disconnect the three electrical terminals (11).

NOTE : Before disconnection, attach the two electrical terminals that


____
are connected to the same terminal stud together with tape.

(5) Pull the lens (5) away from the mirror (10).

(6) Remove the two screws (6) and the two washers (7).

(7) Carefully remove and keep the halogen bulb (9).

(8) If the gasket (12) on the support (13) is defective, remove and
discard it.



EFF :

ALL  33-46-11

Page 424
May 01/07
R  
IAC 
Lens and Mirror of the Take Off Light (7LR)
Figure 404/TASK 33-46-11-991-007



EFF :

ALL  33-46-11

Page 425
May 01/07
R  
IAC 
Subtask 33-46-11-420-057

B. Installation of the Lens and the Mirror

(1) Carefully put the halogen bulb (9) in position on a new mirror (10).

NOTE : If the halogen bulb is damaged, replace it.


____

NOTE : Make sure that the pinched seal (8) end points forward.
____

(2) Install the two washers (7) and the two screws (6).

(3) Tighten the two screws (6). Tighten them one more quarter turn after
contact.

(4) Install a new gasket (12) on the support (13).

(5) Put a new lens (5) in position on a new mirror (10) with the halogen
bulb installed.

(6) Connect the three electrical terminals (11) to the lamp.

NOTE : After connection, remove the tape that attaches the two
____
electrical terminals together.

(7) Put the lamp in position on the support (13).

(8) Put the retainer (4) in position.

NOTE : If the retainer (4) is twisted, replace it.


____

(9) Install the insulating washer (1), the washer (3), and the screw (2).

(10) Put a gage with a thickness of 11 mm (0.4330 in.) between the two
brackets of the retainer (4).

(11) Tighten the screw (2) until the two brackets touch the gage without
visual signs of distortion of the retainer (4).

(12) Remove the gage.

Subtask 33-46-11-865-069

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
- 3LR.



EFF :

ALL  33-46-11

Page 426
May 01/07
R  
IAC 
Subtask 33-46-11-710-055

D. Operational Test

(1) Do the operational test of the take off light (Ref. TASK 33-46-00-
710-001).

5. Close-up
________

Subtask 33-46-11-942-055

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-46-11

Page 427
May 01/07
 
IAC 
LIGHT - TAKE OFF (7LR) - ADJUSTMENT/TEST
________________________________________

TASK 33-46-11-730-001

Adjustment of the Take Off Light (7LR)

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2 MINUTES


_______
AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

R CAUTION : MAKE SURE THAT THE ITEMS IN THE FIXTURES, TOOLS, TEST AND SUPPORT
_______
R EQUIPMENT PARAGRAPH ARE APPLICABLE TO YOUR AIRCRAFT (THIS LIST IS
R NOT CUSTOMIZED). REFER TO THE APPLICABLE SUBTASKS.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific strap
98D33403500000 1 ADJUSTING TOOL - TAKE OFF LIGHT

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 19-010 USA AMS 5687


LOCKWIRE STAINLESS STEEL ANNEALED 0.8MM DIA
(Ref. 20-31-00)


R

EFF :

001-012, 014-099,  33-46-11

Page 501
May 01/06
 
IAC 
C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

08-22-00-200-001 Precise Leveling


33-46-11-991-004 Fig. 501

3. __________
Job Set-up

Subtask 33-46-11-865-062

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TO 3LR W07

Subtask 33-46-11-860-050

B. Aircraft Maintenance Configuration

(1) Make sure that the aircraft fuselage is in the horizontal position.

(2) If not, do the precise leveling (Ref. TASK 08-22-00-200-001).

4. Procedure
_________

(Ref. Fig. 501/TASK 33-46-11-991-004)

Subtask 33-46-11-820-051

A. Adjustment of the Take Off Light with the Tool

(1) Install the ADJUSTING TOOL - TAKE OFF LIGHT (98D33403500000) on the
light.

(2) Set the clinometer to an angle of 0 deg. + or - 2 minutes. Put it


against the tool (3) to make sure that the installation is vertical.

(3) Adjust the tool (3) if necessary and tighten the nuts (2).


R

EFF :

001-012, 014-099,  33-46-11

Page 502
May 01/06
 
IAC 
Adjustment of the Take Off Light
Figure 501/TASK 33-46-11-991-004


R

EFF :

001-012, 014-099,  33-46-11

Page 503
May 01/06
 
IAC 
(4) Angular adjustment of the take off light

(a) Set the clinometer to an angle of 0 deg. 12 minutes + or - 2


minutes (nose up).

(b) Put the clinometer on the applicable zone of the tool,


perpendicular to the light and attach it with the strap.

(c) Tighten or loosen the nuts (1) of the lower fork to get the angle
of 0 deg. 12 minutes + or - 2 minutes.

(d) Tighten the nuts (1) and make sure that the adjustment is
correct.

(e) Remove the clinometer and the ADJUSTING TOOL - TAKE OFF LIGHT
(98D33403500000).

(f) Safety the nuts (1) together with MISCELLANEOUS (Material No. 19-
010).

5. Close-up
________

Subtask 33-46-11-865-063

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
3LR


R

EFF :

001-012, 014-099,  33-46-11

Page 504
May 01/06
 
IAC 
TASK 33-46-11-730-001- 01

Adjustment of the Take Off Light (7LR) - Alternative Procedure

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2 MINUTES


_______
AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific screen

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 19-010 USA AMS 5687


LOCKWIRE STAINLESS STEEL ANNEALED 0.8MM DIA
(Ref. 20-31-00)

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

08-22-00-200-001 Precise Leveling


AMM 11-21-08 P.Block 001 LEVELING AND WEIGHING
33-46-11-991-005 Fig. 502


R

EFF :

001-012, 014-099,  33-46-11

Page 505
May 01/06
 
IAC 
3. __________
Job Set-up

Subtask 33-46-11-865-064

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TAXI 1LR W08

Subtask 33-46-11-860-051

B. Aircraft Maintenance Configuration

(1) Make sure that the the aircraft is on a horizontal surface.

(2) Do a precise leveling (Ref. TASK 08-22-00-200-001).

4. Procedure
_________

(Ref. Fig. 502/TASK 33-46-11-991-005)

Subtask 33-46-11-820-052

A. Adjustment of the Take Off Light

(1) Install the screen (2) in front of the aircraft. The distance between
the screen and the nose landing gear must be 10 m (32.80 ft.).

NOTE : The screen can be a wooden board with a minimum height of 3 m


____
(9.84 ft.) and a minimum width of 2 m (6.56 ft.).

(2) Angular adjustment of the take off light

(a) Measure the distance X between the aircraft centerline and the
ground. To do this, measure the distance between one of the
leveling triangles and the ground (Ref. AMM 11-21-08 P.Block
001).

NOTE : To get an accurate distance, the aircraft must be on a


____
horizontal surface.

(b) Subtract the vertical value 2.2 m (7.21 ft.) from the distance
X. This gives you the value Y, which is the distance between
the ground and the target on the screen. You must adjust the
light beam to the center of the target.


R

EFF :

001-012, 014-099,  33-46-11

Page 506
May 01/06
 
IAC 
(c) Tighten or loosen the nuts (1) of the lower fork to adjust the
light beam on the target.

(d) Tighten the nuts (1) and make sure that the adjustment is
correct.

(e) Safety the nuts (1) together with MISCELLANEOUS (Material No. 19-
010).

5. Close-up
________

Subtask 33-46-11-865-065

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
3LR


R

EFF :

001-012, 014-099,  33-46-11

Page 507
May 01/06
 
IAC 
Adjustment of the Take Off Light - Alternative Procedure
Figure 502/TASK 33-46-11-991-005- 12 (SHEET 1)


R

EFF :

001-012, 014-099,  33-46-11

Page 508
May 01/06
 
IAC 
Adjustment of the Take Off Light - Alternative Procedure
Figure 502/TASK 33-46-11-991-005- 22 (SHEET 2)


R

EFF :

001-012, 014-099,  33-46-11

Page 509
May 01/06
 
IAC 
LIGHT - TAXI (8LR) - REMOVAL/INSTALLATION
_________________________________________

TASK 33-46-12-000-001

Removal of the Taxi Light (8LR)

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2 MINUTES


_______
AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-027,

33-46-12-991-001-B Fig. 401

**ON A/C 028-099,

33-46-12-991-001-A Fig. 401A

R **ON A/C 101-199, 901-999,

33-46-12-991-001-C Fig. 401B



EFF :

ALL  33-46-12

Page 401
Feb 01/07
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-46-12-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TAXI 1LR W08

4. Procedure
_________

Subtask 33-46-12-020-050

A. Removal of the Taxi Light

**ON A/C 001-012, 014-027,

(Ref. Fig. 401/TASK 33-46-12-991-001-B)

**ON A/C 028-099,

(Ref. Fig. 401A/TASK 33-46-12-991-001-A)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 401B/TASK 33-46-12-991-001-C)

**ON A/C ALL

(1) Disconnect the electrical connector (12) from the socket (11).

(2) Put the blanking caps on the disconnected electrical connector (12)
and the socket (11).

(3) Remove the nut (6), the washer (7), the screw (9) and the washer (8).

(4) Remove the nuts (5), the washers (4), the screws (1) and the washers
(2). During this operation, hold the light (10).



EFF :

ALL  33-46-12

Page 402
Feb 01/07
 
IAC 
Taxi Light
R Figure 401/TASK 33-46-12-991-001-B


R

EFF :

001-012, 014-027,  33-46-12

Page 403
Nov 01/99
 
IAC 
Taxi Light
R Figure 401A/TASK 33-46-12-991-001-A


R

EFF :

028-099,  33-46-12

Page 404
Nov 01/99
 
IAC 
Taxi Light
Figure 401B/TASK 33-46-12-991-001-C


R

EFF :

101-199, 901-999,  33-46-12

Page 405
Feb 01/07
 
IAC 
(5) Remove the light (10) from its support (3).



EFF :

ALL  33-46-12

Page 406
Feb 01/07
R  
IAC 
TASK 33-46-12-400-001

Installation of the Taxi Light (8LR)

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R Material No. 05-002 USA MIL-PRF-8116


PUTTY, ZINC CHROMATE GENERAL PURPOSE (Ref. 20-31-00)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-46-00-710-001 Operational Test of the Taxi and Take Off Lights


33-46-12-730-001 Adjustment of the Taxi Light (8LR)

**ON A/C 001-012, 014-027,

33-46-12-991-001-B Fig. 401

**ON A/C 028-099,

33-46-12-991-001-A Fig. 401A



EFF :

ALL  33-46-12

Page 407
Feb 01/08
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-46-12-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TAXI 1LR W08

4. Procedure
_________

**ON A/C 001-012, 014-099,

Subtask 33-46-12-420-050

A. Installation of the Taxi Light

**ON A/C 001-012, 014-027,

(Ref. Fig. 401/TASK 33-46-12-991-001-B)

**ON A/C 028-099,

(Ref. Fig. 401A/TASK 33-46-12-991-001-A)

**ON A/C 001-012, 014-099,

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Make sure that the filament of the bulb and the lens of the optical
unit are in the correct condition.

(4) Make sure that the clamp is correctly installed.

(5) Put the light (10) on its support (3).



EFF :

ALL  33-46-12

Page 408
Feb 01/08
R  
IAC 
(6) Apply SPECIAL MATERIALS (Material No. 05-002) to the screws (1) and
(9).

(7) Install the light (10) in the lower fork on the support (3).

(8) Put the washer (8) on the screw (9).

(9) Install the screws (9) in the support (3).

(10) Install the washer (7) and tighten the nut (6).

(11) Turn the light to the upper forks.

(12) Install the washers (2) on the screws (1).

(13) Install the screws (1) in the support (3).

(14) Install the washers (4) and tighten the nuts (5).

(15) Adjust the taxi light (Ref. TASK 33-46-12-730-001).

(16) Remove the blanking caps from the electrical connector (12) and the
socket (11).

(17) Make sure that the electrical connector (12) and the socket (11) are
in the correct condition.

(18) Connect the electrical connector (12) to the socket (11) and lock it.

**ON A/C 101-199, 901-999,

Subtask 33-46-12-420-050-A

A. Installation of the Taxi Light

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Make sure that the filament of the bulb and the lens of the optical
unit are in the correct condition.

(4) Make sure that the clamp is correctly installed.

(5) Put the light (10) on its support (3).



EFF :

ALL  33-46-12

Page 409
Feb 01/08
R  
IAC 
(6) Apply SPECIAL MATERIALS (Material No. 05-002) to the screws (1) and
(9).

(7) Install the light (10) in the lower fork on the support (3).

(8) Put the washer (8) on the screw (9).

(9) Install the screws (9) in the support (3).

(10) Install the washer (7) and tighten the nut (6).

(11) Turn the light to the upper forks.

(12) Install the washers (2) on the screws (1).

(13) Install the screws (1) in the support (3).

(14) Install the washers (4) and tighten the nuts (5).

(15) Remove the blanking caps from the electrical connector (12) and the
socket (11).

(16) Make sure that the electrical connector (12) and the socket (11) are
in the correct condition.

(17) Connect the electrical connector (12) to the socket (11) and lock it.

**ON A/C ALL

Subtask 33-46-12-865-052

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LR

Subtask 33-46-12-710-051

C. Operationnal Test of the Light

(1) Do the operational test of the taxi light (Ref. TASK 33-46-00-710-
001).



EFF :

ALL  33-46-12

Page 410
Feb 01/08
R  
IAC 
5. Close-up
________

Subtask 33-46-12-942-050

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-46-12

Page 411
Feb 01/08
R  
IAC 
TASK 33-46-12-960-001

Replacement of the Lamp in the Taxi Light (8LR)

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2 MINUTES


_______
AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

3 lamp 33-46-12 01 -030


3 lamp 33-46-12 01 -050
3 lamp 33-46-12 01A-030
R
6 gasket 33-46-12 01A-110
7 clamp 33-46-12 01 -010
7 clamp 33-46-12 01A-010



EFF :

ALL  33-46-12

Page 412
Feb 01/08
 
IAC 
C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-46-00-710-001 Operational Test of the Taxi and Take Off Lights


33-46-12-991-003-B Fig. 402

3. __________
Job Set-up

Subtask 33-46-12-865-058

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TAXI 1LR W08

4. Procedure
_________

Subtask 33-46-12-020-054-B

A. Removal of the Lamp


(Ref. Fig. 402/TASK 33-46-12-991-003-B)

(1) For the lamp (3):

(a) Remove the four screws (1).

(b) Remove the retainer (2).

(c) Pull the lamp (3) away from the support (5) and disconnect the
two electrical terminals (4).

(d) Remove the lamp (3).

(2) For the lamp (3) (alternate configuration):

(a) Remove the washer (9), the screw (10) and the insulating washer
(8).

(b) Remove the clamp (7).



EFF :

ALL  33-46-12

Page 413
Aug 01/06
 
IAC 
R Lamp of the Taxi Light
R Figure 402/TASK 33-46-12-991-003-B12 (SHEET 1)



EFF :

ALL  33-46-12

Page 414
Aug 01/06
 
IAC 
R Lamp of the Taxi Light
R Figure 402/TASK 33-46-12-991-003-B22 (SHEET 2)



EFF :

ALL  33-46-12

Page 415
Aug 01/06
 
IAC 
(c) Pull the lamp (3) away from the support (5) and disconnect the
two electrical terminals (4).

(d) Remove the lamp (3).

(e) If the gasket (6) on the support (5) is defective, remove and
discard it.

Subtask 33-46-12-420-054-B

B. Installation of the Lamp


(Ref. Fig. 402/TASK 33-46-12-991-003-B)

(1) For the lamp (3):

(a) Connect the two electrical terminals (4) to the new lamp (3) and
install it in position on its support (5). Hold it in this
position.

(b) Put the retainer (2) in position.

(c) Attach the assembly. To do this, tighten the four screws (1).

(2) For the lamp (3) (alternate configuration):

(a) If necessary, install a new gasket (6) in position on its support


(5).

(b) Connect the two electrical terminals (4) to the new lamp (3) and
install it in position on its support (5). Hold it in this
position.

(c) Put the clamp (7) in position.

NOTE : If the clamp is twisted, replace it.


____

(d) Install the insulating washer (8), the washer (9) and the screw
(10).

(e) For the GE technology:


R - Tighten the screw (10) by two turns after the screw head is in
R contact with the bracket.

NOTE : Make sure that there are no visual signs of distortion of


____
the clamp (7).



EFF :

ALL  33-46-12

Page 416
Feb 01/07
 
IAC 
(f) For the SHL technology:
- Put a gage with a thickness of 7 mm (0.2755 in.) between the
two brackets of the clamp (7).
- Tighten the screw (10) until the two brackets touch the gage
without visual signs of distortion of the clamp (7).
- Remove the gage.

Subtask 33-46-12-865-059

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LR

Subtask 33-46-12-710-053

D. Operational Test of the Taxi Light

(1) Do the operational test of the taxi light (Ref. TASK 33-46-00-710-
001).

5. Close-up
________

Subtask 33-46-12-942-053

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-46-12

Page 417
May 01/07
R  
IAC 
TASK 33-46-12-960-002

Replacement of the Halogen Bulb of the Taxi Light (8LR)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


R No specific soap solution

R B. Consumable Materials

R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------

R Material No. 11-010 USA TT-I-735 GRADE A


R ISOPROPYL ALCOHOL (Ref. 20-31-00)
R Material No. 19-003 USA AMS 3819
R LINT-FREE COTTON CLOTH (Ref. 20-31-00)

R C. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

4 retainer 33-46-12 01 -010


4 retainer 33-46-12 01A-010
8 halogen bulb 33-43-11 01 -070
8 halogen bulb 33-43-11 01A-070



EFF :

ALL  33-46-12

Page 418
May 01/07
 
IAC 
R D. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-46-00-710-001 Operational Test of the Taxi and Take Off Lights


33-46-12-991-007 Fig. 403

3. __________
Job Set-up

Subtask 33-46-12-865-066

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TAXI 1LR W08

4. Procedure
_________

(Ref. Fig. 403/TASK 33-46-12-991-007)

Subtask 33-46-12-020-055

A. Removal of the Halogen Bulb

(1) Remove the screw (1), the washer (2) and the insulating washer (3).

(2) Remove the retainer (4).

(3) Pull the lens (5) away from the support (9).

NOTE : Put an adhesive tape to hold the mirror (10) in position on


____
the support (9).

(4) Remove the two screws (6) and the two washers (7).

(5) Carefully remove the halogen bulb (8).



EFF :

ALL  33-46-12

Page 419
May 01/07
 
IAC 
Replacement of the Halogen Bulb
Figure 403/TASK 33-46-12-991-007



EFF :

ALL  33-46-12

Page 420
Aug 01/06
R  
IAC 
Subtask 33-46-12-420-055

B. Installation of the Halogen Bulb

(1) Carefully put a new halogen bulb (8) in position.

NOTE : Make sure that the pinched seal (11) end points forward.
____

(2) Install the two washers (7) and the two screws (6).

(3) Tighten the two screws (6). Apply one more quarter turn to the two
screws (6) after contact.

(4) Remove the adhesive tape from the mirror (10).

(5) Clean the component interface and/or the adjacent area.

R (6) Clean the surface of the lens (5) with CLEANING AGENTS (Material No.
R 11-010) made moist with warm soap solution.

R (7) Dry the surface of the lens (5) with a clean MISCELLANEOUS (Material
R No. 19-003).

R (8) Put the lens (5) in position on the mirror (10).

R (9) Put the retainer (4) in position.

NOTE : If the retainer (4) is twisted, replace it.


____

R (10) Install the insulating washer (3), the washer (2), and the screw (1).

R (11) Put a gage with a thickness of 7 mm (0.2755 in.) between the two
brackets of the retainer (4).

R (12) Tighten the screw (1) until the two brackets touch the gage without
visual signs of distortion of the retainer (4).

R (13) Remove the gage.

Subtask 33-46-12-865-067

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LR



EFF :

ALL  33-46-12

Page 421
May 01/07
 
IAC 
Subtask 33-46-12-710-054

D. Operational Test

(1) Do the operational test of the taxi light (Ref. TASK 33-46-00-710-
001).

5. Close-up
________

Subtask 33-46-12-942-054

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-46-12

Page 422
May 01/07
R  
IAC 
TASK 33-46-12-960-003

Replacement of the Lens and the Mirror of the Taxi Light (8LR)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

4 clamp 33-46-12 01 -010


4 clamp 33-46-12 01A-010
5 lens 33-46-12 01 -060
5 lens 33-46-12 01A-060
9 halogen bulb 33-46-12 01 -070
9 halogen bulb 33-46-12 01A-070
10 mirror 33-46-12 01 -080
10 mirror 33-46-12 01A-080
11 gasket 33-46-12 01A-110

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-46-00-710-001 Operational Test of the Taxi and Take Off Lights


33-46-12-991-008 Fig. 404



EFF :

ALL  33-46-12

Page 423
May 01/07
R  
IAC 
3. __________
Job Set-up

Subtask 33-46-12-865-068

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TAXI 1LR W08

4. Procedure
_________

(Ref. Fig. 404/TASK 33-46-12-991-008)

Subtask 33-46-12-020-057

A. Removal of the Lens and the Mirror

(1) Remove the screw (1), the washer (2) and the insulating washer (3).

(2) Remove the clamp (4).

(3) Pull the lamp away from the support (13).

(4) Disconnect the two electrical terminals (12).

(5) Pull the lens (5) away from the mirror (10).

(6) Remove the two screws (6) and the two washers (7).

(7) Carefully remove and keep the halogen bulb (9).

(8) If the gasket (11) on the support (13) is defective, remove and
discard it.

Subtask 33-46-12-420-057

B. Installation of the Lens and the Mirror

(1) Carefully put the halogen bulb (9) in position on a new mirror (10).

NOTE : If the halogen bulb is damaged, replace it.


____

NOTE : Make sure that the pinched seal (8) end points forward.
____

(2) Install the two washers (7) and the two screws (6).



EFF :

ALL  33-46-12

Page 424
May 01/07
R  
IAC 
Lens and Mirror of the Taxi Light (8LR)
Figure 404/TASK 33-46-12-991-008



EFF :

ALL  33-46-12

Page 425
May 01/07
R  
IAC 
(3) Tighten the two screws (6). Tighten them one more quarter turn after
contact.

(4) Install a new gasket (11) on the support (13).

(5) Put a new lens (5) in position on a new mirror (10) with the halogan
bulb installed.

(6) Put the lamp in position on the support (13).

(7) Put the clamp (4) in position.

NOTE : If the clamp (4) is twisted, replace it.


____

(8) Install the insulating washer (3), the washer (2), and the screw (1).

(9) Put a gage with a thickness of 7 mm (0.2755 in.) between the two
brackets of the clamp (4).

(10) Tighten the screw (1) until the two brackets touch the gage without
visual signs of distortion of the clamp (4).

(11) Remove the gage.

Subtask 33-46-12-865-069

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LR

Subtask 33-46-12-710-055

D. Operational Test

(1) Do the operational test of the taxi light (Ref. TASK 33-46-00-710-
001).

5. Close-up
________

Subtask 33-46-12-942-055

A. Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-46-12

Page 426
May 01/07
 
IAC 
LIGHT - TAXI (8LR) - ADJUSTMENT/TEST
____________________________________

TASK 33-46-12-730-001

Adjustment of the Taxi Light (8LR)

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2 MINUTES


_______
AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

R CAUTION : MAKE SURE THAT THE ITEMS IN THE FIXTURES, TOOLS, TEST AND SUPPORT
_______
R EQUIPMENT PARAGRAPH ARE APPLICABLE TO YOUR AIRCRAFT (THIS LIST IS
R NOT CUSTOMIZED). REFER TO THE APPLICABLE SUBTASKS.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific strap
98D33403501000 1 ADJUSTING TOOL - TAXI LIGHT

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 19-010 USA AMS 5687


LOCKWIRE STAINLESS STEEL ANNEALED 0.8MM DIA
(Ref. 20-31-00)


R

EFF :

001-012, 014-099,  33-46-12

Page 501
May 01/06
 
IAC 
C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

08-22-00-200-001 Precise Leveling


33-46-12-991-004 Fig. 501

3. __________
Job Set-up

Subtask 33-46-12-865-060

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TAXI 1LR W08

Subtask 33-46-12-860-050

B. Aircraft Maintenance Configuration

(1) Make sure that the aircraft fuselage is in the horizontal position.

(2) If not, do the precise leveling (Ref. TASK 08-22-00-200-001).

4. Procedure
_________

(Ref. Fig. 501/TASK 33-46-12-991-004)

Subtask 33-46-12-820-050

A. Adjustment of the Taxi Light with the Tool

(1) Install the ADJUSTING TOOL - TAXI LIGHT (98D33403501000) on the


light.

(2) Set the clinometer to an angle of 0 deg. + or - 2 minutes. Put it


against the tool (3) to make sure that the installation is vertical.

(3) Adjust the tool (3) if necessary and tighten the nuts (2).


R

EFF :

001-012, 014-099,  33-46-12

Page 502
May 01/06
 
IAC 
Adjustment of the Taxi Light
Figure 501/TASK 33-46-12-991-004


R

EFF :

001-012, 014-099,  33-46-12

Page 503
May 01/06
 
IAC 
(4) Angular adjustment of the taxi light

(a) Set the clinometer to an angle of 1 deg. 56 minutes + or - 2


minutes (nose down).

(b) Put the clinometer on the applicable zone of the tool,


perpendicular to the light and attach it with the strap.

(c) Tighten or loosen the nuts (1) of the lower fork to get the angle
of 1 deg. 56 minutes + or - 2 minutes.

(d) Tighten the nuts (1) and make sure that the adjustment is
correct.

(e) Remove the clinometer and the ADJUSTING TOOL - TAXI LIGHT
(98D33403501000).

(f) Safety the nuts (1) together with MISCELLANEOUS (Material No. 19-
010).

5. Close-up
________

Subtask 33-46-12-865-061

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LR


R

EFF :

001-012, 014-099,  33-46-12

Page 504
May 01/06
 
IAC 
TASK 33-46-12-730-001- 01

Adjustment of the Taxi Light (8LR) - Alternative Procedure

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2 MINUTES


_______
AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific screen

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 19-010 USA AMS 5687


LOCKWIRE STAINLESS STEEL ANNEALED 0.8MM DIA
(Ref. 20-31-00)

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

08-22-00-200-001 Precise Leveling


AMM 11-21-08 P.Block 001 LEVELING AND WEIGHING
33-46-12-991-006 Fig. 502


R

EFF :

001-012, 014-099,  33-46-12

Page 505
May 01/06
 
IAC 
3. __________
Job Set-up

Subtask 33-46-12-865-064

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TAXI 1LR W08

Subtask 33-46-12-860-052

B. Aircraft Maintenance Configuration

(1) Make sure that the aircraft is on a horizontal surface.

(2) Do a precise leveling (Ref. TASK 08-22-00-200-001).

4. Procedure
_________

(Ref. Fig. 502/TASK 33-46-12-991-006)

Subtask 33-46-12-820-052

A. Adjustment of the Taxi Light

(1) Install the screen (2) in front of the aircraft. The distance between
the screen and the nose landing gear must be 10 m (32.80 ft.).

NOTE : The screen can be a wooden board with a minimum height of 3 m


____
(9.84 ft.) and a minimum width of 2 m (6.56 ft.).

(2) Angular adjustment of the taxi light

(a) Measure the distance X between the aircraft centerline and the
ground. To do this, measure the distance between one of the
leveling triangles and the ground (Ref. AMM 11-21-08 P.Block
001).

NOTE : To get an accurate distance, the aircraft must be on a


____
horizontal surface.

(b) Subtract the vertical value 2.48 m (8.13 ft.) from the distance
X. This gives you the value Y, which is the distance between
the ground and the target on the screen. You must adjust the
light beam to the center of the target.


R

EFF :

001-012, 014-099,  33-46-12

Page 506
May 01/06
 
IAC 
(c) Tighten or loosen the nuts (1) of the lower fork to adjust the
light beam on the target.

(d) Tighten the nuts (1) and make sure that the adjustment is
correct.

(e) Safety the nuts (1) together with MISCELLANEOUS (Material No. 19-
010).

5. Close-up
________

Subtask 33-46-12-865-065

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LR


R

EFF :

001-012, 014-099,  33-46-12

Page 507
May 01/06
 
IAC 
Adjustment of the Taxi Light - Alternative Procedure
Figure 502/TASK 33-46-12-991-006- 12 (SHEET 1)


R

EFF :

001-012, 014-099,  33-46-12

Page 508
May 01/06
 
IAC 
Adjustment of the Taxi Light - Alternative Procedure
Figure 502/TASK 33-46-12-991-006- 22 (SHEET 2)


R

EFF :

001-012, 014-099,  33-46-12

Page 509
May 01/06
 
IAC 
LOGO LIGHTS - DESCRIPTION AND OPERATION
_______________________________________

1. _______
General
R The logo lights are installed to give illumination of the airlines emblem
R (logo), which is marked on each side of the vertical fin. They come on in
R conjunction with the navigation lights.

2. Component
__________________
Location
(Ref. Fig. 001)

-------------------------------------------------------------------------------
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
3LY LIGHT-LOGO, L 334 33-47-00
4LY LIGHT-LOGO, R 344 33-47-00

R 3. System
__________________
Description
R (Ref. Fig. 002)
R The logo lights 4LY and 5LY are installed on the horizontal stabilizer in
R the zones 334 and 344. Each logo light consists of a housing which contains
R the lamp assembly and a step-down transformer. The step-down transformer
R lower the aircrafts 115VAC to 28VAC power supply.
R The toggle switch NAV/LOGO 3LA, installed on the cockpit overhead panel
R 25VU, controls the logo lights together with the navigation lights. The
R toggle switch has these positions:
R - 2,
R - 1,
R - OFF.
R When you set the toggle switch 3LA to the 1 (2) position the logo lights
R come on automatically with the NAV1 (NAV2) lights during the subsequent
R flight phases:
R - taxiing,
R - take off,
R - landing.

4. Power
____________
Supply
R (Ref. Fig. 002)
R 115 V AC is supplied to each logo light from the normal busbars 101XP and
R 202XP.This is controlled through the circuit breakers 1LY and 2LY. The
R circuit breakers 1LY and 2LY are installed on the circuit breaker panel
R 122VU.



EFF :

ALL  33-47-00

Page 1
Nov 01/04
 
IAC 
R Logo Lights - Component Location
R Figure 001



EFF :

ALL  33-47-00

Page 2
May 01/98
 
IAC 
R Logo Lights - Schematic
R Figure 002



EFF :

ALL  33-47-00

Page 3
May 01/98
 
IAC 
R 5. _________
Operation
R (Ref. Fig. 002)
R With the switch NAV & LOGO (3LA) set to 1 or 2, 115 V AC is supplied to the
R relays 6LA and 7LA. When the flaps are lowered to 15 degrees or more, or the
R landing-gear struts are compressed, a ground signal is received. This
R energizes the coil of the relay 5LY. Power is then supplied to the step-down
R transformer of the light assemblies. From these transformers a decreased
R voltage of 28 V DC is supplied to the logo lights 3LY (4LY) which causes the
R logo lights to go on.
R When the landing-gear is retracted, and the flaps are retracted to less than
R 15 degrees, the ground signal is removed. In this condition, the logo lights
R go out. Also, with the switch 3LA set to OFF, the relays 6LA and 7LA are
R de-energized which causes the logo lights to go out.
R



EFF :

ALL  33-47-00

Page 4
Nov 01/04
 
IAC 
LOGO LIGHTS - DEACTIVATION/REACTIVATION
_______________________________________

TASK 33-47-00-040-001

Deactivation of the logo light lens (cover)

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE CLEAR.
_______
MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR
DAMAGE.

1. __________________
Reason for the Job

Refer to the CDL TASK: 33-5


Logo light lens (cover)

R NOTE : There is an alternative procedure in this Page Block.


____

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


R No specific 1 ACCESS PLATFORM 5M (16 FT)
R No specific AR WARNING NOTICE

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 05-065 C Z-24.380


EROSION PROTECTIVE TAPE (Ref. 20-31-00)
Material No. 05-096 AIB AIMS 04-12-001
POLYURETHANE ADHESIVE TAPE (Ref. 20-31-00)



EFF :

ALL  33-47-00

Page 401
Nov 01/07
 
IAC 
C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied


from the External Power
33-47-11-600-001 Replacement of the Lamp of the Logo Light 3LY (4LY)

3. __________
Job Set-up

Subtask 33-47-00-860-052

R A. Aircraft Maintenance Configuration


R

(1) On panel 25VU make sure that the switch 3LA NAV & LOGO ON/OFF is in
the OFF position.

Subtask 33-47-00-860-053

B. De-energize Electrical Circuits

R (1) De-energize the aircraft electrical circuits


R (Ref. TASK 24-41-00-862-002).
R

Subtask 33-47-00-865-052

C. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/LOGO/L 2LY V03
122VU LIGHTING/LOGO/R 1LY V02

Subtask 33-47-00-941-050

R D. Safety Precautions
R

R (1) Put the WARNING NOTICE in the flight compartment to tell persons not
R to operate the logo light.



EFF :

ALL  33-47-00

Page 402
Nov 01/07
 
IAC 
Subtask 33-47-00-010-051

R E. Get Access
R

R (1) Put the ACCESS PLATFORM 5M (16 FT) in position in zone 334AB for the
R left hand logo light and/or zone 344AB for the right hand logo light.

4. Procedure
_________

Subtask 33-47-00-040-050

A. Deactivation of the logo light lens

(1) Remove the logo light lens (Ref. TASK 33-47-11-600-001).

NOTE : It is not necessary to remove the logo light lamp. You must
____
only remove the lens of the logo light.

(2) Clean the surface around the logo light hole.

R (3) Put the high speed tape SPECIAL MATERIALS (Material No. 05-065) on
R the logo light hole.

NOTE : If this kind of high speed tape is not available you can also
____
use SPECIAL MATERIALS (Material No. 05-096) as alternative
solution.

(4) Write a note in the technical log book that the logo light lens has
been deactivated.

5. Close-up
________

Subtask 33-47-00-865-053

R A. Close this(these) circuit breaker(s):


R 1LY, 2LY
R

Subtask 33-47-00-942-052

B. Removal of Equipment

R (1) Make sure that the work area is clean and clear of tool(s) and other
R items.
R



EFF :

ALL  33-47-00

Page 403
Nov 01/07
 
IAC 
R (2) Remove the access platform(s).
R

R (3) Remove the ground support and maintenance equipment, the special and
R standard tools and all other items.
R



EFF :

ALL  33-47-00

Page 404
Nov 01/07
 
IAC 
TASK 33-47-00-440-001

Reactivation of the logo light lens (cover)

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE CLEAR.
_______
MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR
DAMAGE.

1. __________________
Reason for the Job

Refer to the CDL TASK: 33-5


Logo light lens (cover)

R NOTE : There is an alternative procedure in this Page Block.


____

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


R No specific 1 ACCESS PLATFORM 5M (16 FT)
R No specific AR WARNING NOTICE

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied


from the External Power
33-47-11-600-001 Replacement of the Lamp of the Logo Light 3LY (4LY)



EFF :

ALL  33-47-00

Page 405
Nov 01/07
 
IAC 
3. __________
Job Set-up

Subtask 33-47-00-860-056

R A. Aircraft Maintenance Configuration


R

(1) On panel 25VU make sure that the switch 3LA NAV & LOGO ON/OFF is in
the OFF position.

Subtask 33-47-00-860-057

B. De-energize Electrical Circuits

R (1) De-energize the aircraft electrical circuits


R (Ref. TASK 24-41-00-862-002).
R

Subtask 33-47-00-865-055

C. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/LOGO/L 2LY V03
122VU LIGHTING/LOGO/R 1LY V02

Subtask 33-47-00-941-053

R D. Safety Precautions
R

R (1) Put the WARNING NOTICE in the flight compartment to tell persons not
R to operate the logo light

Subtask 33-47-00-010-050

R E. Get Access
R

R (1) Put the ACCESS PLATFORM 5M (16 FT) in position in zone 334AB for the
R left hand logo light and/or zone 344AB for the right hand logo light.



EFF :

ALL  33-47-00

Page 406
Nov 01/07
 
IAC 
4. Procedure
_________

Subtask 33-47-00-440-051

A. Reactivation of the Logo Light Lens

R (1) Remove the high speed tape cover from the logo light hole.

R (2) Clean the area around the hole of the tape adhesive.

R (3) Install the logo light lens (Ref. TASK 33-47-11-600-001).

(4) Write a note in the aircraft technical log that the logo light lens
of the tail navigation light has been reactivate.

5. Close-up
________

Subtask 33-47-00-865-056

R A. Close this(these) circuit breaker(s):


R 1LY, 2LY
R

Subtask 33-47-00-942-054

B. Remove the equipment

R (1) Make sure that the work area is clean and clear of tool(s) and other
R items.

R (2) Remove the warning notice(s).


R

R (3) Remove the access platform(s).


R

R (4) Remove the ground support and maintenance equipment, the special and
R standard tools and all other items.
R



EFF :

ALL  33-47-00

Page 407
Nov 01/07
 
IAC 
R TASK 33-47-00-040-001- 01

R Deactivation of the logo light lens (cover)

R WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
R START A TASK ON OR NEAR:
R - THE FLIGHT CONTROLS
R - THE FLIGHT CONTROL SURFACES
R - THE LANDING GEAR AND THE RELATED DOORS
R - COMPONENTS THAT MOVE.

R WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE CLEAR.
_______
R MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR
R DAMAGE.

R 1. __________________
Reason for the Job

R Refer to the CDL TASK: 33-5


R Logo light lens (cover)

R NOTE : There is an alternative procedure in this Page Block.


____

R 2. ______________________
Job Set-up Information

R A. Fixtures, Tools, Test and Support Equipment

R -------------------------------------------------------------------------------
R REFERENCE QTY DESIGNATION
R -------------------------------------------------------------------------------

R No specific circuit breaker(s) safety clip(s)


R No specific 1 ACCESS PLATFORM 5M (16 FT)
R No specific AR WARNING NOTICE

R B. Consumable Materials

R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------

R Material No. 08-052 USA AMS-T-23397 AND/OR L-T-80B


R SELF ADHESIVEALUMINIUM TAPE (Ref. 20-31-00)



EFF :

ALL  33-47-00

Page 408
Nov 01/07
 
IAC 
R C. Referenced Information

R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------

R 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied


R from the External Power
R 33-47-11-600-001 Replacement of the Lamp of the Logo Light 3LY (4LY)

R 3. __________
Job Set-up

R Subtask 33-47-00-860-058

R A. Aircraft Maintenance Configuration

R (1) On panel 25VU make sure that the switch 3LA NAV & LOGO ON/OFF is in
R the OFF position.

R Subtask 33-47-00-860-059

R B. De-energize Electrical Circuits

R (1) De-energize the aircraft electrical circuits


R (Ref. TASK 24-41-00-862-002).

R Subtask 33-47-00-865-057

R C. Open, safety and tag this(these) circuit breaker(s):

R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R 122VU LIGHTING/LOGO/L 2LY V03
R 122VU LIGHTING/LOGO/R 1LY V02

R Subtask 33-47-00-941-055

R D. Safety Precautions

R (1) Put the WARNING NOTICE in the flight compartment to tell persons not
R to operate the logo light.



EFF :

ALL  33-47-00

Page 409
Nov 01/07
 
IAC 
R Subtask 33-47-00-010-052

R E. Get Access

R (1) Put the ACCESS PLATFORM 5M (16 FT) in position 334AB for the left
R hand logo light and/or zone 344AB for the right hand logo light.

R 4. Procedure
_________

R Subtask 33-47-00-040-051

R A. Deactivation of the logo light lens

R (1) Remove the logo light lens (Ref. TASK 33-47-11-600-001).

R NOTE : It is not necessary to remove the logo light lamp. You must
____
R only remove the lens of the logo light.

R (2) Clean the surface around the logo light hole.

R (3) Put the high speed tape BONDING AND ADHESIVE COMPOUNDS (Material No.
R 08-052) on the logo light hole.

R (4) Write a note in the technical log book that the logo light lens has
R been deactivated.

R 5. Close-up
________

R Subtask 33-47-00-942-055

R A. Removal of Equipment

R (1) Make sure that the work area is clean and clear of tool(s) and other
R items.

R (2) Remove the access platform(s).

R (3) Remove the ground support and maintenance equipment, the special and
R standard tools and all other items.



EFF :

ALL  33-47-00

Page 410
Nov 01/07
 
IAC 
R TASK 33-47-00-440-001- 01

R Reactivation of the logo light lens (cover)

R WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
R START A TASK ON OR NEAR:
R - THE FLIGHT CONTROLS
R - THE FLIGHT CONTROL SURFACES
R - THE LANDING GEAR AND THE RELATED DOORS
R - COMPONENTS THAT MOVE.

R WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE CLEAR.
_______
R MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR
R DAMAGE.

R 1. __________________
Reason for the Job

R Refer to the CDL TASK: 33-5


R Logo light lens (cover)

R NOTE : There is an alternative procedure in this Page Block.


____

R 2. ______________________
Job Set-up Information

R A. Fixtures, Tools, Test and Support Equipment

R -------------------------------------------------------------------------------
R REFERENCE QTY DESIGNATION
R -------------------------------------------------------------------------------

R No specific 1 ACCESS PLATFORM 5M (16 FT)


R No specific AR WARNING NOTICE

R B. Referenced Information

R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------

R 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied


R from the External Power
R 33-47-11-600-001 Replacement of the Lamp of the Logo Light 3LY (4LY)



EFF :

ALL  33-47-00

Page 411
Nov 01/07
 
IAC 
R 3. __________
Job Set-up

R Subtask 33-47-00-860-060

R A. Aircraft Maintenance Configuration

R (1) On panel 25VU make sure that the switch 3LA NAV & LOGO ON/OFF is in
R the OFF position.

R Subtask 33-47-00-860-061

R B. De-energize Electrical Circuits

R (1) De-energize the aircraft electrical circuits


R (Ref. TASK 24-41-00-862-002).

R Subtask 33-47-00-865-058

R C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
R tagged

R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R 122VU LIGHTING/LOGO/L 2LY V03
R 122VU LIGHTING/LOGO/R 1LY V02

R Subtask 33-47-00-941-056

R D. Safety Precautions

R (1) Put the WARNING NOTICE in the flight compartment to tell persons not
R to operate the logo light.

R Subtask 33-47-00-010-053

R E. Get Access

R (1) Put the ACCESS PLATFORM 5M (16 FT) in position in zone 334AB for the
R left hand logo light and/or zone 344AB for the right hand logo light.



EFF :

ALL  33-47-00

Page 412
Nov 01/07
 
IAC 
R 4. Procedure
_________

R Subtask 33-47-00-440-052

R A. Reactivation of the Logo Light Lens

R (1) Remove the high speed tape cover from the logo light hole.

R (2) Clean the area around the hole of the tape adhesive.

R (3) Install the logo light lens (Ref. TASK 33-47-11-600-001).

R (4) Write a note in the aircraft technical log that the logo light lens
R of the tail navigation light has been reactivate.

R 5. Close-up
________

R Subtask 33-47-00-865-059

R A. Close this(these) circuit breaker(s):


R 1LY, 2LY

R Subtask 33-47-00-942-056

R B. Remove the equipment

R (1) Make sure that the work area is clean and clear of tool(s) and other
R items.

R (2) Remove the warning notice(s).

R (3) Remove the access platform(s).

R (4) Remove the ground support and maintenance equipment, the special and
R standard tools and all other items.



EFF :

ALL  33-47-00

Page 413
Nov 01/07
 
IAC 
LOGO LIGHTS - ADJUSTMENT/TEST
_____________________________

TASK 33-47-00-710-002

Operational Test of the Logo Lights

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

To make sure that the logo lights operate correctly.

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
27-50-00-866-008 Extension of the Flaps on the Ground
27-50-00-866-009 Retraction of the Flaps on the Ground
31-32-00-860-009 Procedure to Get Access to the SYSTEM REPORT/TEST/L/G
Page
R 32-00-00-860-001 Flight Configuration Precautions with Electrical
R Power
R 32-00-00-860-002 Ground Configuration after Flight Configuration with
R Electrical Power

3. __________
Job Set-up

Subtask 33-47-00-860-050

A. Aircraft Maintenance Configuration

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

(2) Do the procedure of the flight configuration precautions (Ref. TASK


32-00-00-860-001).

(3) Get access to the L/G page on the MCDU (Ref. TASK 31-32-00-860-009).



EFF :

ALL  33-47-00

Page 501
May 01/06
 
IAC 
Subtask 33-47-00-865-051

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/LOGO/L 2LY V03
122VU LIGHTING/LOGO/R 1LY V02
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/CTL 2LR W09

4. Procedure
_________

Subtask 33-47-00-710-050-A

A. Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the overhead panel 25VU: On the Trimmable Horizontal Stabilizer


(THS):

- set the NAV/LOGO control switch - the logo lights 3LY and 4LY come on.
3LA to the 2 position.

2. In the cockpit, on the MCDU: On the MCDU:

- push the LGCIU2 line select - the LGCIU2 MENU page comes on.
key.

- push the NEXT PAGE pushbutton - the LANDING GEAR SIMULATION page
comes on.

- push the LANDING GEAR - the LANDING GEAR SIMULATION menu


SIMULATION line select key. comes on.

- push the LH+RH line select key. - the LH+RH menu page comes on.



EFF :

ALL  33-47-00

Page 502
Aug 01/06
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- push the EXTENDED line select On the THS:
key. - the logo lights 3LY and 4LY go off.

3. Put the slat/flap control lever On the THS:


to position 2 to extend the - the logo lights 3LY and 4LY come on.
flaps (Ref. TASK 27-50-00-866-
008)

4. On the overhead panel 25VU: On the THS:

- set the NAV/LOGO control switch - the logo lights 3LY and 4LY remain
3LA to the 1 position. on.

5. Put the slat/flap control lever On the THS:


to position 0 to retract the - the logo lights 3LY and 4LY go off.
flaps (Ref. TASK 27-50-00-866-
009)

6. In the cockpit, on the MCDU: On the THS:


- push the RETURN line select - the logo lights 3LY and 4LY come on.
key, until the SYSTEM
REPORT/TEST menu page comes on.

7. On the overhead panel 25VU: On the THS:

- set the NAV/LOGO control switch - the logo lights 3LY and 4LY go off.
3LA to the OFF position.

5. Close-up
________

Subtask 33-47-00-860-051

A. Put the aircraft back to its initial configuration.

(1) On the MCDU, put the BRT switch to OFF.

(2) Do the procedure of ground configuration after flight configuration


(Ref. TASK 32-00-00-860-002).

(3) De- energize the aircraft electrical circuits (Ref. TASK 24-41-00-
862-002).

(4) Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-47-00

Page 503
May 01/06
R  
IAC 
LIGHT - LOGO - MAINTENANCE PRACTICES
____________________________________

TASK 33-47-11-600-001

Replacement of the Lamp of the Logo Light 3LY (4LY)

WARNING : ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE
_______
ENVIRONMENT.

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE CLEAR.
_______
MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR
DAMAGE.

NOTE : The procedure is the same for the two logo lights.
____

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific warning notices
No specific access platform 5.0 m (16 ft. 5 in.)

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R Material No. 09-001 USA MIL-S-8802 TYPE I CLASS A


R FUEL TANK SEALANTPOLYSULFIDE (Ref. 20-31-00)
Material No. 16-016 C Z-12.383
EXTERNAL DECORATION PAINT (Ref. 20-31-00)



EFF :

ALL  33-47-11

Page 201
Aug 01/07
 
IAC 
C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
R 33-47-00-710-002 Operational Test of the Logo Lights
33-47-11-991-001 Fig. 201

3. __________
Job Set-up

Subtask 33-47-11-860-051

A. Aircraft Maintenance Configuration

(1) On panel 25VU make sure that the switch 3LA NAV & LOGO ON/OFF is in
the OFF position.

Subtask 33-47-11-860-050

B. De-energize Electrical Circuits

(1) De-energize the aircraft electrical circuits


(Ref. TASK 24-41-00-862-002).

Subtask 33-47-11-865-050

C. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 3LY
122VU LIGHTING/LOGO/L 2LY V03
FOR 4LY
122VU LIGHTING/LOGO/R 1LY V02



EFF :

ALL  33-47-11

Page 202
Aug 01/07
 
IAC 
R

Subtask 33-47-11-941-050

R D. Safety Precautions
R

(1) Put the warning notices in the flight compartment to tell persons not
to operate the logo lights.

R (2) Put the access platform in position at zone 334 for the left logo
R light and/or zone 344 for the right logo light.

4. Procedure
_________

(Ref. Fig. 201/TASK 33-47-11-991-001)

Subtask 33-47-11-020-052

R A. Removal of the Lamp

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.

(1) Remove the countersunk screws (1) around the frame assembly (2).

(2) Remove the frame assembly (2) and the seal (3).

(3) Release the quick-release fasteners (5) and remove the attach ring
(4).

(4) Remove the beam lamp (6) with the seal (8).

Subtask 33-47-11-020-053

B. Disconnect Electrical Connectors

R (1) Remove the screws (10) and disconnect the terminals of the electrical
R wires (11) from the electrical connector (7).

(2) Put blanking caps on the disconnected electrical connectors.



EFF :

ALL  33-47-11

Page 203
Aug 01/06
 
IAC 
R Lamp of the Logo Light 3LY/4LY
Figure 201/TASK 33-47-11-991-001



EFF :

ALL  33-47-11

Page 204
Aug 01/06
 
IAC 
Subtask 33-47-11-420-050

C. Replace the Lamp

(1) Replace the beam lamp (6) if necessary.

Subtask 33-47-11-420-052

D. Install the Lamp

(1) Remove the blanking caps from the electrical connectors.

(2) Connect the terminals of the electrical wires (11) in the electrical
connectors (7) of the beam lamp (6).

NOTE : Make sure that the terminals of the electrical wires (11) are
____
correctly positioned in the electrical connectors (7).

(3) Install the screws (10) in the electrical connectors (7).

(4) Install the beam lamp (6) with the seal (8) and tighten it with the
attach ring (4).

(5) Tighten the quick-release fasteners (5).

(6) Install the seal ring (3) and the frame assembly (2) and tighten it
with the countersunk screws (1).

R (7) Apply a fillet of SEALANTS (Material No. 09-001) between the frame
R assembly (2) contour and the spar box skin surface.

Subtask 33-47-11-370-050

E. Painting

(1) Apply STRUCTURE PAINTS (Material No. 16-016) to the heads of the
countersunk screws (1).

R Subtask 33-47-11-865-063

R F. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):

R (1) 2LY, 1LY



EFF :

ALL  33-47-11

Page 205
Aug 01/07
 
IAC 
R Subtask 33-47-11-710-053

R G. Operational Test

R (1) Do an operational test of the logo light (Ref. TASK 33-47-00-710-


R 002).

5. Close-up
________

Subtask 33-47-11-942-054

R A. Removal of the Equipment

(1) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.

(2) Remove the access platform(s).

(3) Remove the warning notice(s).

(4) Make sure that the work area is clean and clear of tool(s) and other
items.

Subtask 33-47-11-861-053

R B. Energize the aircraft electrical circuits

(1) Energize the aircraft electrical circuits


(Ref. TASK 24-41-00-861-002).



EFF :

ALL  33-47-11

Page 206
Aug 01/07
 
IAC 
LIGHT - LOGO - REMOVAL/INSTALLATION
___________________________________

TASK 33-47-11-000-002

Removal of the Logo Light 3LY (4LY)

WARNING : ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE
_______
ENVIRONMENT.

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE CLEAR.
_______
MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR
DAMAGE.

NOTE : The procedure is the same for the two logo lights.
____

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific warning notices
No specific access platfom 5.0 m (16 ft. 5 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied


from the External Power
33-47-11-991-003 Fig. 401



EFF :

ALL  33-47-11

Page 401
Aug 01/06
 
IAC 
3. __________
Job Set-up

Subtask 33-47-11-860-056

A. Aircraft Maintenance Configuration

(1) On panel 25VU make sure that the switch 3LA NAV & LOGO ON/OFF is in
the OFF position.

(2) De-energize the aircraft electrical circuits


(Ref. TASK 24-41-00-862-002).

Subtask 33-47-11-865-059

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/LOGO/L 2LY V03
122VU LIGHTING/LOGO/R 1LY V02

Subtask 33-47-11-941-054

C. Safety Precautions

(1) Put the warning notices in the flight compartment to tell the persons
not to operate the logo lights.

(2) Put the access platfom in position at zone 334 for the left logo
light and/or zone 344 for the right logo light.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-47-11-991-003)

Subtask 33-47-11-020-057

A. Removal of the Logo Light

(1) Remove the screws (1) around the frame assembly (2).

(2) Remove the frame assembly (2) and the seal (3).

(3) Remove the screws (9) from the housing (4) and remove the housing
(4).



EFF :

ALL  33-47-11

Page 402
Aug 01/06
 
IAC 
Logo Light 3YL/4YL
Figure 401/TASK 33-47-11-991-003



EFF :

ALL  33-47-11

Page 403
Aug 01/06
 
IAC 
(4) Disconnent the electrical connector (5).

(5) Remove the screw (6), the washer (7) and the bonding lead (8) from
the bottom of the housing (4).



EFF :

ALL  33-47-11

Page 404
Aug 01/06
 
IAC 
TASK 33-47-11-400-002

Installation of the Logo Light 3LY (4LY)

WARNING : ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE
_______
ENVIRONMENT.

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE CLEAR.
_______
MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR
DAMAGE.

NOTE : The procedure is the same for the two logo lights.
____

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 05-013 D TV-53-3507/73


RELEASE AGENT (OBSOLETE USE 05-013A) (Ref. 20-31-00)
Material No. 09-001 USA MIL-S-8802 TYPE I CLASS A
FUEL TANK SEALANTPOLYSULFIDE (Ref. 20-31-00)
Material No. 16-016 C Z-12.383
EXTERNAL DECORATION PAINT (Ref. 20-31-00)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-47-00-710-002 Operational Test of the Logo Lights


33-47-11-991-003 Fig. 401



EFF :

ALL  33-47-11

Page 405
Aug 01/06
 
IAC 
3. __________
Job Set-up

Subtask 33-47-11-860-057

A. Aircraft Maintenance Configuration

(1) On panel 25VU make sure that the switch 3LA NAV & LOGO is in the OFF
position.

(2) Make sure that the aircraft electrical circuits are de-energized.

(3) Make sure that the platform is in position at zone 334 for the left
logo light and/or 344 for the right logo light.

Subtask 33-47-11-865-060

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/LOGO/L 2LY V03
122VU LIGHTING/LOGO/R 1LY V02

Subtask 33-47-11-210-052

C. Preparation for Installation

(1) Make sure that the parts retained from the removed component are
clean and in the correct conditions.

(2) Do a visual inspection of the component interface and/or adjacent


area.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-47-11-991-003)

Subtask 33-47-11-420-056

A. Installation of the Logo Light

(1) Install the bonding lead (8), the washer (7) and the screw (6).

(2) Connect the electrical connector (5).



EFF :

ALL  33-47-11

Page 406
Aug 01/06
 
IAC 
(3) Apply a layer of SEALANTS (Material No. 09-001) to the spar box skin
that will be in contact with the housing logo light (4) and apply a
layer of SPECIAL MATERIALS (Material No. 05-013) to the housing logo
light surface that will be in contact with the spar box skin.

(4) Put in position the logo light housing (4) and tighten the screws
(9).

(5) Apply a layer of SPECIAL MATERIALS (Material No. 05-013) on both


sides of the seal (3) and put the seal (3) in position on the logo
light housing (4).

(6) Put the frame assy (2) in position on the seal (3) and tighten the
screws (1).

(7) Apply a fillet of SEALANTS (Material No. 09-001) between the frame
assy contour and the spar box skin surface.

Subtask 33-47-11-370-054

B. Painting

(1) Apply STRUCTURE PAINTS (Material No. 16-016) to the heads of the
screws (1).

R Subtask 33-47-11-865-061

R C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):

R (1) 2LY, 1LY

Subtask 33-47-11-710-052

R D. Operational Test

(1) Do an operational test of the logo light (Ref. TASK 33-47-00-710-


002).



EFF :

ALL  33-47-11

Page 407
Aug 01/07
 
IAC 
5. Close-up
________

Subtask 33-47-11-942-052

R A. Removal of the Equipment

(1) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.

(2) Remove the access platform(s).

(3) Remove the warning notice(s).

(4) Make sure that the work area is clean and clear of tool(s) and other
items.



EFF :

ALL  33-47-11

Page 408
Aug 01/07
 
IAC 
ANTI-COLLISION/STROBE LIGHTING - DESCRIPTION AND OPERATION
__________________________________________________________

1. General
_______

A. The aircraft recognition lighting system is designed as a visual aid to


other aircraft, so reducing the possibility of a collosion.
The system consists of:
- an anti-collision light providing a high-intensity red flashing light
on the top and on the bottom of the aircraft fuselage.
- a strobe light providing a high-intensity white flashing light. One
light is installed in each wing tip facing forward and one is installed
in the tailcone, below the APU exhaust, facing rearwards.

2. __________________
Component Location

**ON A/C 001-012, 014-099,

(Ref. Fig. 001)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 001A)

**ON A/C ALL

-------------------------------------------------------------------------------
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
3LV PWR SPLY UNIT-UPPER BEACON 244 33-48-36
4LV PWR SPLY UNIT-LOWER BEACON 192 33-48-37
6LV LIGHT-BEACON, LOWER 191 33-48-12
7LV LIGHT-BEACON, UPPER 244 33-48-11
14LV PWR SPLY UNIT-WING TIP STROBE LIGHT 634 634AB 33-48-38
632
15LV PWR SPLY UNIT-L WING TIP STROBE 534 534AB 33-48-38
LIGHT 631
16LV LIGHT-STROBE, R WING TIP 634 33-48-14
17LV LIGHT - STROBE, L WING TIP 534 33-48-14
18LV PWR SPLY UNIT-TAIL CONE STROBE LIGHT 311 33-48-39
19LV LIGHT-STROBE, TAIL CONE 317 33-48-13



EFF :

ALL  33-48-00

Page 1
Feb 01/07
 
IAC 
Anti-Collision/Beacon and Strobe Lighting - Component Location
Figure 001 (SHEET 1)


R

EFF :

001-012, 014-099,  33-48-00

Page 2
May 01/06
 
IAC 
Anti-Collision/Beacon and Strobe Lighting - Component Location
Figure 001 (SHEET 2)


R

EFF :

001-012, 014-099,  33-48-00

Page 3
May 01/06
 
IAC 
Anti-Collision/Beacon and Strobe Lighting - Component Location
Figure 001A (SHEET 1)


R

EFF :

101-199, 901-999,  33-48-00

Page 4
Feb 01/07
 
IAC 
Anti-Collision/Beacon and Strobe Lighting - Component Location
Figure 001A (SHEET 2)


R

EFF :

101-199, 901-999,  33-48-00

Page 5
Feb 01/07
 
IAC 
3. __________________
System Description

**ON A/C 001-012, 014-099,

(Ref. Fig. 002)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 002A)

**ON A/C ALL

(Ref. Fig. 003)


The aircraft recognition lighting system consists of two independent systems
which are designed to operate alternately in synchronization:
- the anti-collision light system and
- the strobe light system.
The anti-collision/beacon light system operates, when the BEACON ON-OFF
control switch (2LV), located on the overhead panel 25VU, is in the ON
position. This causes the power supply units (3LV) and (4LV) to energize
and supply the upper and lower anti-collision lights/beacon lights (6LV)
and (7LV) with power.
The strobe light system operates, when the STROBE ON-AUTO-OFF control
switch (11LV), located on the overhead panel 25VU, is in the ON/AUTO
position. This causes the power supply units (14LV), (15LV) and (18LV) to
energize and supply the two strobe lights (16LV) and (17LV) on each wing
tip and the strobe light (19LV) on the tailcone with power.
If a malfunction should occur at the high-intensity strobe lights (white)
or their power supply units, this does not have an affect of the function
of the fuselage anti-collision light (red).

**ON A/C 001-012, 014-099,

A. Anti-Collision/Beacon Lights
The two anti-collision/beacon lights which do not rotate flash at a rate
of 60 +/- 10 flashes per minute. Both lights give 360 degrees of
horizontal, and 75 degrees of vertical diffusion.



EFF :

ALL  33-48-00

Page 6
Feb 01/07
 
IAC 
Anti-Collision/Beacon Light and Strobe Lights
Figure 002


R

EFF :

001-012, 014-099,  33-48-00

Page 7
May 01/06
 
IAC 
Anti-Collision/Beacon Light and Strobe Lights
Figure 002A


R

EFF :

101-199, 901-999,  33-48-00

Page 8
Feb 01/07
 
IAC 
Anti-Collision/Beacon Light and Strobe Light - Power Unit
Figure 003



EFF :

ALL  33-48-00

Page 9
May 01/06
R  
IAC 
B. Strobe Lights
The two forward facing strobe lights and the rearward facing strobe light
flash at the same time at a rate of 60 +/- 10 flashes per minute.
Additionally a second flash tube in the forward facing strobe lights
flashes at a rate of 60 +/- 10 flashes per minute. This produces 120 +/-
10 flashes per minute in the forward direction and 60 +/- 10 flashes per
minute in the rearward direction.

**ON A/C 101-199, 901-999,

A. Anti-Collision/Beacon Lights
R The two anti-collision/beacon lights which do not turn, flash at a rate
R of 55 +/- 5 flashes per minute. The two lights give 360 degrees of
R horizontal, and 75 degrees of vertical diffusion.

B. Strobe Lights
The two forward facing strobe lights and the rearward facing strobe light
R flash at the same time at a rate of 55 +/- 5 flashes per minute. A second
R flash tube in the forward facing strobe lights flashes at a rate of 55
R +/- 5 flashes per minute. This gives 110 +/- 10 flashes per minute in the
R forward direction and 55 +/- 5 flashes per minute in the rearward
R direction.

**ON A/C ALL

4. Power
____________
Supply
The 115VAC 101XP and 202XP are three phase busbars which supply power
through the circuit breakers 1LV and 5LV to the power units 3LV and 4LV. The
power units, which control the flash rate, supply the power to each
anti-collision/beacon light.
The 115VAC three phase busbar 202XP supplies power through the circuit
breaker 10LV to the power units 14LV,15LV and 18LV. The power units, which
control the flash rate, supply power to each strobe light. The landing gear
computer supplies 28VDC to the coil of the relay 13LV when the landing gear
struts are compressed.

5. _____________________
Component Description

**ON A/C 001-012, 014-099,

(Ref. Fig. 002)



EFF :

ALL  33-48-00

Page 10
Nov 01/07
 
IAC 
R **ON A/C 101-199, 901-999,

(Ref. Fig. 002A)

**ON A/C ALL

A. Anti-Collision/Beacon and Strobe Light


The anti-collision/beacon and the rearward facing strobe light consists
of a flash tube mounted on a reflection. The tube is enclosed in a
faraday cage, and covered by a red glass for the anti-collision/beacon
and a white lens for the strobe light. The forward facing strobe light
consists of two tubes enclosed in a metal case with a faraday cage in the
white lens.

(1) A transformer is mounted in the base of the light. The housing of the
anti-collision/beacon transformer is provided with cooling fins.

(2) A start electrode is used to start the flash tube.

(3) The seperate power unit supplies the anode/cathode with a 400 to
500VDC. Also it supplies a start pulse for the anti-collision/beacon
and the strobe lights.

B. Power Unit
(Ref. Fig. 004)
The power unit supplies a high voltage frequency to start and operate the
anti-collision/beacon and the strobe lights. In the forward facing strobe
light there are two circuits the same.

(1) The power unit consists of an E.M.I. filter. It is a symmetrical


LC-LC filter which reduces the anount of interference to the supply
leads to an acceptable level.

(2) An AC/DC Converter converts the 200V/400Hz input power to the various
DC voltages used in the power unit.

(3) The flash rate is given by a timer to the connected light unit.

(4) A blocking converter divides the D.C. voltage, transformer it to a


higher voltage and then rectifies it.

(5) The capacitor charging voltage is limited to almost 450VDC by a


voltage limitor. This provides a discharge path when the output
circuit is open.



EFF :

ALL  33-48-00

Page 11
Feb 01/07
 
IAC 
(6) The blocking converter is made inoperative after each flash by an arc
blanking circuit. It reduces the arc-burning current of the connected
light unit to give complete arc-suppression.

(7) The output-pulse for synchronisation between the power unit is


produced by a clock generator.

(8) A chargeable accumulator which consist of series parallel connected


capacitors and a charge circuit.

(9) The start impulse generator produces a high voltage frequency


ascillation for the transformer in the connected power unit.

6. Operation
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 004)

A. Anti-Collision/Beacon Lights
The system is supplied with power when the busbars are energized and the
circuit breakers 1LV and 5LV are closed. The power control relay contacts
8LV and 9LV are supplied with 200VAC. The control switch 2LV in the
BEACON ON position energizes the relay 8LV and 9LV. The power units 3LV
and 4LV are supplied with 200VAC. The anti-collision light 7LV and 6LV
flash at a rate of 60+-10 flashes per minutes.

**ON A/C 101-199, 901-999,

(Ref. Fig. 004)

R A. Anti-Collision/Beacon Lights
The system is supplied with power when the busbars are energized and the
circuit breakers 1LV and 5LV are closed. The power control relay contacts
8LV and 9LV are supplied with 200VAC. The control switch 2LV in the
BEACON ON position energizes the relay 8LV and 9LV. The power units 3LV
and 4LV are supplied with 200VAC. The anti-collision light 7LV and 6LV
R flash at a rate of 55 +/- 5 flashes per minute.



EFF :

ALL  33-48-00

Page 12
Nov 01/07
 
IAC 
Anti-Collision/Beacon and Strobe Lighting - Schematic
Figure 004



EFF :

ALL  33-48-00

Page 13/14
May 01/06
 
IAC 
R **ON A/C ALL

B. Strobe Light
The strobe light system is supplied with three phase 200VAC/400Hz when
the busbar is energized and the circuit breaker 10LV is closed.

(1) With the switch STROBE 11LV set to AUTO, 115VAC is supplied to the
power relay 12LV. 28VDC, from the landing gear computer, is removed
when the landing gear struts are extended. This de-energizes the coil
of the control relay 13LV and gives a ground signal for the power
relay 12LV. The power units 14LV, 15LV and 18LV are supplied with
200VAC. From these power units an increased voltage is produced to
operate the strobe lights 16LV, 17LV and 19LV.
28VDC is supplied to the coil of relay 13LV when the landing gear
struts are compressed. This energizes the coil of the control relay
13LV and removes the ground signal. The power relay 12LV is
de-energized and the three phase 200VAC/400Hz is removed from the
power units 14LV, 15LV and 18LV.

(2) With the switch STROBE 11LV set to ON, 115VAC is supplied to the
power relay 12LV. It also gives a ground signal for the coil of the
power relay 12LV. The power units 14LV, 15LV and 18LV are supplied
with three phase 200VAC/400Hz from the power relay 12LV. The strobe
lights flash as described.

(3) With the switch STROBE 11LV set to OFF:


- the 115VAC is removed from the coil of power relay 12LV.
- the ground signal is removed from the coil of power relay 12LV.



EFF :

ALL  33-48-00

Page 15
May 01/06
 
IAC 
ANTI-COLLISION/STROBE LIGHTING - DEACTIVATION/REACTIVATION
__________________________________________________________

TASK 33-48-00-040-001

Deactivation of the Anti-Collision (Beacon) Lights 6LV and 7LV

1. __________________
Reason for the Job

Refer to the CDL TASK: 33-4


Upper and lower anti-collision
Light lens (cover)

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific soap solution
No specific 1 ACCESS PLATFORM 6M (20 FT)
No specific 1 WARNING NOTICE

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R Material No. 08-061 D DAN 328AS


TAPE SOUND DAMPENINGALUMINIUM FOIL (Ref. 20-31-00)
Material No. 19-003 USA AMS 3819
LINT-FREE COTTON CLOTH (Ref. 20-31-00)



EFF :

ALL  33-48-00

Page 401
Feb 01/07
 
IAC 
C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-48-00-710-002 Operational Test of the Anti-Collision/Strobe


Lighting
33-48-11-000-001 Removal of the Upper Beacon/Strobe Light 7LV from the
Outside of the Fuselage
33-48-12-000-001 Removal of the Lower Beacon/Strobe Light 6LV from the
Fuselage Outside

**ON A/C 001-012, 014-099,

33-48-00-991-001 Fig. 401

R **ON A/C 101-199, 901-999,

33-48-00-991-001-A Fig. 401A

**ON A/C ALL

3. __________
Job Set-up

Subtask 33-48-00-941-052

A. Aircraft Maintenance Configuration

(1) Make sure that the strobe lights operate correctly (Ref. TASK 33-48-
00-710-002).

(2) For the upper anti-collision light:


- Put the ACCESS PLATFORM 6M (20 FT) in position at the upper
anti-collision light.

(3) Put a WARNING NOTICE in position to tell persons not to operate the
anti-collision lights.



EFF :

ALL  33-48-00

Page 402
Feb 01/07
 
IAC 
Subtask 33-48-00-865-052

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/UPPER 1LV U06
122VU LIGHTING/EXT LT/BEACON/LOWER 5LV U03

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-48-00-991-001)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-48-00-991-001-A)

**ON A/C 001-012, 014-099,

Subtask 33-48-00-040-050

A. Deactivation of the Anti-Collision Lights

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.

(1) Remove the countersunk screws (1) from the lens (23) (Ref. TASK 33-
48-11-000-001) or (Ref. TASK 33-48-12-000-001).

NOTE : Make match marks on the screws (1) and/or their positions to
____
help with the installation procedure (different screw sizes).

(2) Remove and discard the remaining part of the lens (23) and the seal
(22) or (32).

(3) Remove the countersunk screws (3) from the plate (18).



EFF :

ALL  33-48-00

Page 403
Feb 01/07
 
IAC 
Anti-Collision (Beacon) Lights
Figure 401/TASK 33-48-00-991-001


R

EFF :

001-012, 014-099,  33-48-00

Page 404
May 01/06
 
IAC 
Anti-Collision (Beacon) Lights
Figure 401A/TASK 33-48-00-991-001-A


R

EFF :

101-199, 901-999,  33-48-00

Page 405
Feb 01/07
 
IAC 
(4) Lift the light assembly until you can see the electrical connector
(9).

(5) Disconnect the electrical connector (9) from the light assembly and
support the electrical connector (9).

(6) Remove the screws (2) from the cage (20) and remove the cage (20).

(7) Remove the screws (11) from the housing (12) and remove the housing
(12).

(8) Disconnect the electrical connectors (17) from the transformer (13).

NOTE : Put identification labels on the electrical leads. This will


____
help you to install the electrical connectors (17) again.

(9) Carefully remove the reflector (19) from the plate (18).

NOTE : Remove only the reflector (19) and not the light assembly.
____

(10) Install the transformer (13) in the housing (12) with the screws
(11).

(11) Install the plate (18) on the housing (12) with the screws (2).

(12) Make sure that the electrical connectors are clean and in the correct
condition.

(13) Connect the electrical connector (9) to the transformer (13).

(14) Install the plate (18) and the seal (14) or (34) on the flange (10)
with the countersunk screws (3).

(15) Make and install a cover for the cable hole in the plate (18) from
the high speed tape, BONDING AND ADHESIVE COMPOUNDS (Material No. 08-
061).

(16) Clean the surface of the fuselage (8) around the anti-collision light
with a lint-free cotton cloth, MISCELLANEOUS (Material No. 19-003)
made moist with a warm soap solution.

(17) Make sure that no liquid goes into the inside of the plate (18).

(18) Dry the surface with a dry lint-free cotton cloth, MISCELLANEOUS
(Material No. 19-003).



EFF :

001-012, 014-099,  33-48-00

Page 406
Feb 01/07
R  
IAC 
(19) Apply the high speed tape, BONDING AND ADHESIVE COMPOUNDS (Material
No. 08-061) on the top of the plate (18) and the adjacent area of the
fuselage (8).

NOTE : Do not cover the removed reflector (19) with tape.


____

(20) Make sure that the high speed tape is installed correctly. The high
speed tape must seal all of the opening for the anti-collision light.

(21) Write in the aircraft technical log that the anti-collision light has
a temporary repair.

(22) Keep the circuit breakers 1LV and 5LV open, safetied and tagged.

R **ON A/C 101-199, 901-999,

Subtask 33-48-00-040-050-A

A. Deactivation of the Anti-Collision Lights

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.

(1) Remove the countersunk screws (1) from the lens (23) (Ref. TASK 33-
48-11-000-001) or (Ref. TASK 33-48-12-000-001).

NOTE : Make match marks on the screws (1) and/or their positions to
____
help with the installation procedure (different screw sizes).

(2) Remove and discard the remaining part of the lens (23) and the seal
(22) or (32).

(3) Remove the screws (2) from the flash tube assy (21).

(4) Remove the countersunk screws (3) from the housing (15).

(5) Lift the housing (15) sufficiently to get access to the plate (4).

(6) Remove the screws (5) from the plate (4).

(7) Remove the plate (4) from the housing (15).

(8) Remove the screw (6) from the transformer (7).



EFF :

ALL  33-48-00

Page 407
Feb 01/07
 
IAC 
(9) Remove the transformer (7) from the housing (15).

(10) Support the transformer (7) and disconnect the electrical connectors
(17) from the transformer (7).

NOTE : Put identification labels on the electrical leads. This will


____
help you to install the electrical connectors (17) again.

(11) Carefully remove the flash tube assy (21) from the housing (15).

NOTE : Remove only the flash tube assy (21) and not the light
____
assembly.

(12) Install the transformer (7) in the housing (15) with the screw (6).

(13) Install the plate (4) on the housing (15) with the screws (5).

(14) Install the housing (15) and the seal (14) or (34) on the flange (10)
with the countersunk screws (3).

(15) Make and install a cover for the cable hole in the housing (15) from
the high speed tape, BONDING AND ADHESIVE COMPOUNDS (Material No. 08-
061).

(16) Clean the surface of the fuselage (8) around the anti-collision light
with a lint-free cotton cloth, MISCELLANEOUS (Material No. 19-003)
made moist with a warm soap solution.

(17) Make sure that no liquid goes into the inside of the housing (15).

(18) Dry the surface with a dry lint-free cotton cloth, MISCELLANEOUS
(Material No. 19-003).

(19) Apply the high speed tape, BONDING AND ADHESIVE COMPOUNDS (Material
No. 08-061) on the top of the housing (15) and the adjacent area of
the fuselage (8).

NOTE : Do not cover the removed flash tube assy (21) with tape.
____

(20) Make sure that the high speed tape is installed correctly. The high
speed tape must seal all of the opening for the anti-collision light.

(21) Write in the aircraft technical log that the anti-collision light has
a temporary repair.

(22) Keep the circuit breakers 1LV and 5LV open, safetied and tagged.


R

EFF :

101-199, 901-999,  33-48-00

Page 408
Feb 01/07
 
IAC 
**ON A/C ALL

TASK 33-48-00-440-001

Reactivation of the Anti-Collision (Beacon) Lights 6LV and 7LV

1. __________________
Reason for the Job

Refer to the CDL TASK: 33-4


Upper and lower anti-collision
Light lens (cover)

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific 1 ACCESS PLATFORM 6M (20 FT)


No specific 1 WARNING NOTICE

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 07-001B


ELECTRICAL BONDING COATING (BLUE COLOR)
(Ref. 20-31-00)
Material No. 09-013 C Z-16.127
CORROSION INHIBITING BRUSH CONSISTENCY
(Ref. 20-31-00)


R

EFF :

ALL  33-48-00

Page 409
Feb 01/07
 
IAC 
C. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

FOR FIN 6LV


14 seal 33-48-12 01 -040
14 seal 33-48-12 02 -110
22 seal 33-48-12 01 -030
22 seal 33-48-12 02 -030
FOR FIN 7LV
32 seal 33-48-11 01 -030
32 seal 33-48-11 01A-030
34 seal 33-48-11 01 -040
34 seal 33-48-11 01A-040
34 seal 33-48-11 01A-110

D. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

20-21-11-911-001 Tightening Torques for Standard Threaded Fasteners


20-28-00-912-004 Electrical Bonding of Components With Conductive
Bolts and Screws and Bonding Straps in the Fuselage
and in the Wings (this does not include the tanks)-
33-48-11-400-001 Installation of the Upper Beacon/Strobe Light 7LV
from the Outside of the Fuselage
33-48-12-400-001 Installation of the Lower Beacon/Strobe Light 6LV
from the Fuselage Outside

**ON A/C 001-012, 014-099,

33-48-00-991-001 Fig. 401

R **ON A/C 101-199, 901-999,

33-48-00-991-001-A Fig. 401A



EFF :

ALL  33-48-00

Page 410
Feb 01/07
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-48-00-941-053

A. Aircraft Maintenance Configuration

(1) Make sure that the WARNING NOTICE is in position to tell persons not
to operate the anti-collision lights.

(2) For the upper anti-collision light:


- Put the ACCESS PLATFORM 6M (20 FT) in position at the upper
anti-collision light.

Subtask 33-48-00-865-053

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/UPPER 1LV U06
122VU LIGHTING/EXT LT/BEACON/LOWER 5LV U03

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-48-00-991-001)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-48-00-991-001-A)



EFF :

ALL  33-48-00

Page 411
Feb 01/07
 
IAC 
INTENTIONALLY BLANK


R



 33-48-00

Page 412
Feb 01/07
 
IAC 
R **ON A/C 001-012, 014-099,

Subtask 33-48-00-440-050

A. Reactivation of the Anti-Collision Lights

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.

NOTE : For the torque values of the screws see the related AMM 20-21-11
____
(Ref. TASK 20-21-11-911-001).

(1) Remove the tape from the related anti-collision light.

(2) Remove the tape from the cable hole in the plate (18) of the
anti-collision light.

(3) Clean the component interface and/or the adjacent area.

(4) Remove the countersunk screws (3) from the plate (18).

(5) Lift the light assembly until you can see the electrical connector
(9).

(6) Disconnect the electrical connector (9) from the light assembly and
support the electrical connector (9).

(7) Replace the seal:


FOR 6LV
discard the seal (14) and install a new seal (14).
FOR 7LV
discard the seal (34) and install a new seal (34).

(8) Remove the screws (2) from the plate (18) and remove the plate (18).

(9) Remove the screws (11) from the housing (12) and remove the
transformer (13).

(10) Make sure that the work area is clean and clear of tool(s) and other
items.

(11) Make sure that the ignition wire of the xenon flash tube is fixed
below the reflector (19).



EFF :

001-012, 014-099,  33-48-00

Page 413
May 01/06
 
IAC 
(12) Put the leads of the reflector (19) through the cable hole of the
plate (18).

(13) Install the reflector (19) on the plate (18).

(14) Make sure that the electrical connectors are clean and in the correct
condition.

(15) Connect the electrical connectors (17) to the transformer (13).

NOTE : Obey the identification labels made during the removal


____
procedure to get the correct polarity and remove the
identification labels.

(16) Install the transformer (13) in the housing (12) with the screws
(11).

(17) Install the cage (20), the reflector (19) and the plate (18) on the
housing (12) with the screws (2).

(18) Connect the electrical connector (9) to the light assembly.

(19) Install the plate (18) and the seal (14) or (34) on the flange (10)
with the countersunk screws (3).

(20) Apply the SEALANTS (Material No. 09-013) to the heads of the
countersunk screws (3) (Ref. TASK 20-28-00-912-004) and let it dry.

(21) Apply the PAINTS FOR DETAIL (INTERNAL AND EXTERN AL) (Material No.
07-001B) to the head of the countersunk screw (3) which gives the
electrical bonding.

(22) For the lens drain plug of the new lens (23) obey subsequent:
FOR 6LV
remove the lens drain plug from the new lens (23) if installed.

NOTE : You must remove the lens drain plug from the new lens (23) to
____
prevent that the condensed water stays in the lens (23).

FOR 7LV
make sure that the lens drain plug is correctly installed in the new
lens (23).



EFF :

001-012, 014-099,  33-48-00

Page 414
May 01/06
 
IAC 
(23) Install a new seal:
FOR 6LV
install a new seal (22).
FOR 7LV
install a new seal (32).

(24) Install the new lens (23) on the fuselage (8) with the countersunk
screws (1) (Ref. TASK 33-48-11-400-001) or (Ref. TASK 33-48-12-400-
001).

NOTE : Refer to the match marks made during the removal procedure for
____
the screw (1) installation in the correct position.

R **ON A/C 101-199, 901-999,

Subtask 33-48-00-440-050-A

A. Reactivation of the Anti-Collision Lights

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.

NOTE : For the torque values of the screws see the related AMM 20-21-11
____
(Ref. TASK 20-21-11-911-001).

(1) Remove the tape from the related anti-collision light.

(2) Remove the tape from the cable hole in the housing (15) of the
anti-collision light.

(3) Clean the component interface and/or the adjacent area.

(4) Remove the countersunk screws (3) from the housing (15).

(5) Lift the housing (15) until you can see the electrical connector (9).

(6) Disconnect the electrical connector (9) from the housing (15) and
support the electrical connector (9).



EFF :

ALL  33-48-00

Page 415
Feb 01/07
 
IAC 
(7) Replace the seal:
FOR 6LV
discard the seal (14) and install a new seal (14).
FOR 7LV
discard the seal (34) and install a new seal (34).

(8) Make sure that the electrical connectors are clean and in the correct
condition.

(9) Connect the electrical connector (9) to the housing (15).

(10) Remove the screws (5) and the plate (4) from the housing (15).

(11) Remove the screw (6) and the transformer (7) from the housing (15).

(12) Support the transformer (7).

(13) Make sure that the work area is clean and clear of tool(s) and other
items.

(14) Put the leads of the flash tube assy (21) through the cable hole of
the housing (15).

(15) Install the flash tube assy (21) on the housing (15).

(16) Make sure that the electrical connectors are clean and in the correct
condition.

(17) Connect the electrical connectors (17) to the transformer (7).

NOTE : Obey the identification labels made during the removal


____
procedure to get the correct polarity and remove the
identification labels.

(18) Install the transformer (7) in the housing (15) with the screw (6).

(19) Install the plate (4) on the housing (15) with the screws (5).

(20) Install the housing (15) and the seal (14) or (34) on the flange (10)
with the countersunk screws (3).

(21) Apply the SEALANTS (Material No. 09-013) to the heads of the
countersunk screws (3) (Ref. TASK 20-28-00-912-004) and let it dry.

(22) Apply the PAINTS FOR DETAIL (INTERNAL AND EXTERN AL) (Material No.
07-001B) to the head of the countersunk screw (3) which gives the
electrical bonding.


R

EFF :

101-199, 901-999,  33-48-00

Page 416
Feb 01/07
 
IAC 
R (23) Install the flash tube assy (21) on the housing (15) with the four
R screws (2).

R (24) For the rubber bung (24) of the new lens (23) obey subsequent:
R FOR 6LV
R remove the rubber bung (24) from the new lens (23) if installed.

R NOTE : You must remove the rubber bung (24) from the new lens (23) to
____
R prevent that the condensed water stays in the lens (23).

R FOR 7LV
R make sure that the rubber bung (24) is correctly installed in the new
R lens (23).

R (25) Install a new seal:


R FOR 6LV
R install a new seal (22).
R FOR 7LV
R install a new seal (32).

R (26) Install the new lens (23) on the fuselage (8) with the countersunk
R screws (1) (Ref. TASK 33-48-11-400-001) or (Ref. TASK 33-48-12-400-
R 001).

R NOTE : The pin (16) must engage in the rubber bung (24) if installed.
____

R NOTE : Refer to the match marks made during the removal procedure for
____
R the screw (1) installation in the correct position.

R **ON A/C ALL

5. Close-up
________

Subtask 33-48-00-942-052

A. Put the aircraft back to the serviceable condition.

(1) Remove the warning notice(s).

(2) Remove the access platform(s).

(3) Write in the aircraft technical log that the lens of the
anti-collision light has been replaced.



EFF :

ALL  33-48-00

Page 417
May 01/06
 
IAC 
Subtask 33-48-00-865-054

B. Make sure that this(these) circuit breaker(s) is(are) closed:


1LV, 5LV



EFF :

ALL  33-48-00

Page 418
May 01/06
 
IAC 
ANTI-COLLISION/STROBE LIGHTING - ADJUSTMENT/TEST
________________________________________________

TASK 33-48-00-710-001

Operational Test of the Anti-Collision/Strobe Lighting

WARNING : DO NOT LOOK DIRECTLY AT THE LIGHT FLASH DURING THE TEST.
_______
SUPPLY A COVER, OR SHIELD, TO GIVE PROTECTION FROM THE LIGHT FLASH TO
PERSONS IN THE TEST AREA.

1. __________________
Reason for the Job

Make sure that the Beacon/Strobe Lights operate correctly.

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-48-00-861-050

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-48-00-865-050

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/EXT LT/BEACON/UPPER 1LV U06
122VU LIGHTING/EXT LT/BEACON/LOWER 5LV U03



EFF :

ALL  33-48-00

Page 501
Aug 01/06
 
IAC 
R

4. Procedure
_________

WARNING : DO NOT LOOK DIRECTLY AT THE LIGHT FLASH DURING THE TEST.
_______
SUPPLY A COVER, OR SHIELD, TO GIVE PROTECTION FROM THE LIGHT FLASH
TO PERSONS IN THE TEST AREA.

**ON A/C 001-012, 014-099,

Subtask 33-48-00-710-050

A. Test of the Anti-Collision/Strobe Lighting

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the overhead panel 25VU: On the upper and lower fuselage:


- put the switch BEACON 2LV to - the upper beacon light 7LV and the
the ON position. lower beacon light 6LV come on.
These lights flash at a rate of
approx. 60 flashes per minute.

2. On the overhead panel 25VU: On the upper and lower fuselage:


- put the switch BEACON 2LV to - the upper beacon light 7LV and the
the OFF position. lower beacon light 6LV go off.



EFF :

ALL  33-48-00

Page 502
Aug 01/06
 
IAC 
**ON A/C 101-199, 901-999,

Subtask 33-48-00-710-050-A

A. Test of the Anti-Collision/Strobe Lighting

R (1) Do this test:

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

R 1. On the overhead panel 25VU: On the upper and lower fuselage:

R
R - Put the switch BEACON 2LV in - The upper beacon light 7LV and the
R the ON position. lower beacon light 6LV come on.
R These lights flash at a rate of 55
R +/- 5 flashes per minute.

R 2. On the overhead panel 25VU: On the upper and lower fuselage:

R
R - Put the switch BEACON 2LV in - The upper beacon light 7LV and the
R the OFF position. lower beacon light 6LV go off.

**ON A/C ALL

5. Close-up
________

Subtask 33-48-00-862-050

A. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-48-00

Page 503
Nov 01/07
 
IAC 
TASK 33-48-00-710-002

Operational Test of the Anti-Collision/Strobe Lighting

WARNING : DO NOT LOOK DIRECTLY AT THE LIGHT FLASH DURING THE TEST.
_______
SUPPLY A COVER, OR SHIELD, TO GIVE PROTECTION FROM THE LIGHT FLASH TO
PERSONS IN THE TEST AREA.

1. __________________
Reason for the Job

Make sure that the Beacon/Strobe lights (Red) and the Strobe lights (White)
operate correctly.

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
31-32-00-860-009 Procedure to Get Access to the SYSTEM REPORT/TEST/L/G
Page

3. __________
Job Set-up

Subtask 33-48-00-861-051

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-48-00-865-051

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/UPPER 1LV U06
122VU LIGHTING/EXT LT/BEACON/LOWER 5LV U03
122VU LIGHTING/WING/STROBE 10LV V05



EFF :

ALL  33-48-00

Page 504
Feb 01/07
R  
IAC 
Subtask 33-48-00-869-050

C. Do the procedure to get access to the SYSTEM REPORT/TEST LG page of the


CFDS. (Ref. TASK 31-32-00-860-009).

4. Procedure
_________

WARNING : DO NOT LOOK DIRECTLY AT THE LIGHT FLASH DURING THE TEST.
_______
SUPPLY A COVER, OR SHIELD, TO GIVE PROTECTION FROM THE LIGHT FLASH
TO PERSONS IN THE TEST AREA.

**ON A/C 001-012, 014-099,

Subtask 33-48-00-710-051

A. Test of the Anti-Collision/Strobe Lighting

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the overhead panel 25VU: On the upper and lower fuselage:


- put the switch BEACON 2LV to - the upper beacon light 7LV and the
the ON position. lower beacon light 6LV come on.
These lights flash at a rate of
approx. 60 flashes per minute.

2. On the overhead panel 25VU: On the wing tips and tailcone:


- put the switch STROBE 11LV to - the strobe lights 17LV and 16LV at
the ON position. the end of the wing tips come on.
- the strobe light 19LV at the tailcone
below the APU exhaust comes on.
These lights flash at a rate of
approx. 60 flashes per minute.

NOTE : Make sure that the strobe lights


____
flash in different
synchronization with the upper
and lower beacon lights.

3. In the cockpit on the EXT LT On the wing tips and tailcone:


panel 25VU:
- put the switch STROBE 11LV to - the strobe lights go off.
the AUTO position.



EFF :

ALL  33-48-00

Page 505
Feb 01/07
R  
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
4. On the SYSTEM/REPORT TEST L/G On the MCDU:
page of the MCDU: - the LGCIU 2 page comes on.
- push the LGCIU 2 line key.
- push the NEXT PAGE pushbuttom - the LANDING GEAR MENU page comes on.
switch.
- push the LANDING GEAR - the LGCIU LANDING GEAR SIMULATION
SIMULATION line key. MENU page comes on.
- push the LH + RH line key.
- the LGCIU LH + RH MENU page comes on.

- push the EXTENDED line key. - the strobe lights come on and flash
in alternate synchronization with the
- push the COMPRESSED line key. upper and lower beacons.
- the strobe lights go off.

- push the RETURN line key. - the LGCIU MENU LANDING GEAR
SIMULATION page comes on.
- push the RETURN line key. - the LGCIU MENU page comes on.

- push the RETURN line key. - the SYSTEM REPORT/TEST L/G page comes
on.

5. In the cockpit on the EXT LT On the wing tips and tailcone:


panel 25VU:
- put the switch STROBE 11LV to - the strobe lights stay off.
the OFF position.

6. On the overhead panel 25VU: On the upper and lower fuselage:


- put the switch BEACON 2LV to - the upper beacon light 7LV and the
the OFF position. lower beacon light 6LV go off.



EFF :

001-012, 014-099,  33-48-00

Page 506
Feb 01/07
R  
IAC 
**ON A/C 101-199, 901-999,

Subtask 33-48-00-710-051-A

A. Test of the Anti-Collision/Strobe Lighting

R (1) Do this test:

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

R 1. On the overhead panel 25VU: On the upper and lower fuselage:

R
R - Put the switch BEACON 2LV in - The upper beacon light 7LV and the
R the ON position. lower beacon light 6LV come on.
R These lights flash at a rate of 55
R +/- 5 flashes per minute.

R 2. On the overhead panel 25VU: On the wing tips and the tailcone:

R
R - Put the switch STROBE 11LV in - The strobe lights 17LV and 16LV at
R the ON position. the end of the wing tips come on.
R - The strobe light 19LV at the tailcone
R below the APU exhaust comes on.
R These lights flash at a rate of 55
R +/- 5 flashes per minute.

R NOTE : It is necessary, that the strobe


____
R lights flash in different
R synchronization with the upper
R and lower beacon lights.

R 3. In the cockpit on the EXT LT On the wing tips and the tailcone:
panel 25VU:

R - Put the switch STROBE 11LV in - The strobe lights go off.


R the AUTO position.

R 4. On the SYSTEM/REPORT TEST L/G On the MCDU:


page of the MCDU:

R - Push the LGCIU 2 line key. - The LGCIU 2 page comes on.



EFF :

101-199, 901-999,  33-48-00

Page 507
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
R - Push the NEXT PAGE pushbutton - The LANDING GEAR MENU page comes on.
R switch.

R - Push the LANDING GEAR - The LGCIU LANDING GEAR SIMULATION


R SIMULATION line key. MENU page comes on.

R - Push the LH + RH line key. - The LGCIU LH + RH MENU page comes on.
R

R - Push the EXTENDED line key. - The strobe lights come on and flash
R in alternate synchronization with the
R upper and lower beacons.

R
R - Push the COMPRESSED line key. - The strobe lights go off.

R - Push the RETURN line key. - The LGCIU MENU LANDING GEAR
R SIMULATION page comes on.

R - Push the RETURN line key. - The LGCIU MENU page comes on.

R
R - Push the RETURN line key. - The SYSTEM REPORT/TEST L/G page comes
R on.

R 5. In the cockpit on the EXT LT On the wing tips and the tailcone:
panel 25VU:

R - Put the switch STROBE 11LV in - The strobe lights stay off.
R the OFF position.

R 6. On the overhead panel 25VU: On the upper and lower fuselage:

R
R - Put the switch BEACON 2LV in - The upper beacon light 7LV and the
R the OFF position. lower beacon light 6LV go off.


R

EFF :

101-199, 901-999,  33-48-00

Page 508
Nov 01/07
 
IAC 
**ON A/C ALL

5. Close-up
________

Subtask 33-48-00-860-050

A. Close Access

(1) On the MCDU, push the line key adjacent to the RETURN indication
until the CFDS menu page comes into view.

(2) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY
potentiometers to OFF.

Subtask 33-48-00-862-051

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-48-00

Page 509
Nov 01/07
 
IAC 
LIGHT - BEACON, UPPER (7LV) - REMOVAL/INSTALLATION
__________________________________________________

TASK 33-48-11-000-001

Removal of the Upper Beacon/Strobe Light 7LV from the Outside of the Fuselage

WARNING : ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE
_______
ENVIRONMENT.

NOTE : You can also remove the upper beacon/strobe light from the inside of the
____
fuselage (Ref. TASK 33-48-11-000-002).

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific access platform 6.0 m (19 ft. 8 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-099,

33-48-11-991-004 Fig. 401

R **ON A/C 101-199, 901-999,

33-48-11-991-004-A Fig. 401A



EFF :

ALL  33-48-11

Page 401
Feb 01/07
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-48-11-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/UPPER 1LV U06

Subtask 33-48-11-010-055

B. Get Access

(1) Make sure that the switch 2LV BEACON ON-OFF on the overhead panel
25VU is in the OFF position.

(2) Put the access platform in position.

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-48-11-991-004)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-48-11-991-004-A)

**ON A/C ALL

Subtask 33-48-11-020-051

A. Removal of the upper beacon/strobe light 7LV

(1) Remove the countersunk screws (11) from the lens (9).

NOTE : Make match marks on the screws (11) and/or their positions to
____
help with the installation procedure (different screw sizes).



EFF :

ALL  33-48-11

Page 402
Feb 01/07
 
IAC 
R Upper Beacon/Strobe Light 7LV
Figure 401/TASK 33-48-11-991-004



EFF :

001-012, 014-099,  33-48-11

Page 403
Feb 01/08
 
IAC 
R Upper Beacon/Strobe Light 7LV
Figure 401A/TASK 33-48-11-991-004-A



EFF :

101-199, 901-999,  33-48-11

Page 404
Nov 01/07
 
IAC 
(2) Remove the lens (9) and discard the seal (8).

(3) Remove the countersunk screws (5) from the light assembly (2).

(4) Lift the light assembly (2) until the electrical connector (1) is
visible.

(5) Disconnect the electrical connector (1) from the light assembly (2).

(6) Put blanking caps on the disconnected electrical connectors.

(7) Remove the light assembly (2) with the seal (12) from the aircraft.

(8) Discard the seal (12).



EFF :

ALL  33-48-11

Page 405
Feb 01/07
R  
IAC 
TASK 33-48-11-400-001

Installation of the Upper Beacon/Strobe Light 7LV from the Outside of the
Fuselage

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 07-001B


ELECTRICAL BONDING COATING (BLUE COLOR)
(Ref. 20-31-00)
R Material No. 09-013 C Z-16.127
CORROSION INHIBITING BRUSH CONSISTENCY
(Ref. 20-31-00)

B. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

8 seal 33-48-11 01 -030


8 seal 33-48-11 01A-030
12 seal 33-48-11 01 -040
12 seal 33-48-11 01A-040



EFF :

ALL  33-48-11

Page 406
May 01/06
 
IAC 
C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R 20-21-11-911-001 Tightening Torques for Standard Threaded Fasteners


20-28-00-912-004 Electrical Bonding of Components With Conductive
Bolts and Screws and Bonding Straps in the Fuselage
and in the Wings (this does not include the tanks)-
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

**ON A/C 001-012, 014-099,

33-48-11-991-004 Fig. 401

**ON A/C 101-199, 901-999,

33-48-11-991-004-A Fig. 401A

**ON A/C ALL

3. __________
Job Set-up

Subtask 33-48-11-860-052

A. Aircraft Maintenance Configuration

(1) Make sure that the parts retained from the removed component are
clean and in the correct condition.

(2) Make sure that the switch 2LV BEACON ON-OFF on the overhead panel
25VU is in the OFF position.



EFF :

ALL  33-48-11

Page 407
Nov 01/07
 
IAC 
Subtask 33-48-11-865-053

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/UPPER 1LV U06

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-48-11-991-004)

**ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-48-11-991-004-A)

R **ON A/C ALL

R WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL MATERIALS


_______
R ONLY WITH A GOOD SUPPLY OF AIR.
R OBEY THE MANUFACTURERS INSTRUCTIONS.
R PUT ON PROTECTIVE CLOTHING.
R DO NOT GET THEM IN YOUR MOUTH.
R DO NOT SMOKE.
R DO NOT BREATHE THE GAS.
R THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT.
R GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.

**ON A/C 001-012, 014-099,

Subtask 33-48-11-420-051

A. Installation of the Upper Beacon/Strobe Light 7LV

R NOTE : For the torque values that you must use for the screws, refer to
____
R (Ref. TASK 20-21-11-911-001).

(1) Clean the component interface and/or the adjacent area.



EFF :

ALL  33-48-11

Page 408
Nov 01/07
 
IAC 
(2) Do an inspection of the component interface and/or the adjacent area.

(3) Prepare the electrical bonding point at the flange (3) (Ref. TASK 20-
28-00-912-004).

(4) Remove the blanking caps from the electrical connectors.

(5) Make sure that the electrical connectors are clean and in the correct
condition.

(6) Connect the electrical connector (1) to the light assembly (2).

R (7) Use the correct sequence when you tighten the countersunk screws (5).
R Install the light assembly (2) and the new seal (12) with the
R countersunk screws (5) on the flange (3).

(8) Apply SEALANTS (Material No. 09-013) to the heads of the countersunk
screws (5) and let it dry.

(9) Apply PAINTS FOR DETAIL (INTERNAL AND EXTERN AL) (Material No. 07-
001B) to the head of the countersunk screw (5) which gives the
electrical bonding.

R (10) On all lights, but not on PN 2LA55010-00:

R (a) Use the correct sequence when you tighten the countersunk screws
R (11).
R Install the lens (9) with a new seal (8) and the countersunk
R screws (11) and tighten.

R NOTE : It is necessary to refer to the match marks made during


____
R the removal procedure for the countersunk screw (11)
R installation in the correct position.

(b) Make sure that the lens drain plug (10) is installed.

(11) On lights with PN 2LA55010-00:

(a) Make sure that the bung (10) is correctly installed in the lens
(9).

R (b) Use the correct sequence when you tighten the countersunk screws
R (11).
R Install the lens (9) with a new seal (8) and the countersunk
R screws (11) and tighten.


R

EFF :

001-012, 014-099,  33-48-11

Page 409
Nov 01/07
 
IAC 
R NOTE : It is necessary to refer to the match marks made during
____
R the removal procedure for the screw (11) installation in
R the correct position.

R (12) Make sure that the pin (13) engages in the bung (10).

**ON A/C 101-199, 901-999,

Subtask 33-48-11-420-051-A

A. Installation of the Upper Beacon/Strobe Light 7LV.

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Prepare the electrical bonding point at the flange (3) (Ref. TASK 20-
28-00-912-004).

(4) Remove the blanking caps from the electrical connectors.

(5) Make sure that the electrical connectors are clean and in the correct
condition.

(6) Connect the electrical connector (1) to the light assembly (2).

R (7) Use the correct sequence when you tighten the countersunk screws (5).
R Install the light assembly (2) and the new seal (12) with the
R countersunk screws (5) on the flange (3).

(8) Apply SEALANTS (Material No. 09-013) to the heads of the countersunk
screws (5) (Ref. TASK 20-28-00-912-004) and let it dry.

(9) Apply PAINTS FOR DETAIL (INTERNAL AND EXTERN AL) (Material No. 07-
001B) to the head of the countersunk screw (5) which gives the
electrical bonding.

(10) Make sure that the bung (10) is correctly installed in the lens (9).

R (11) Use the correct sequence when you tighten the countersunk screws
R (11).
R Install the lens (9) with a new seal (8) and the countersunk screws
R (11) and tighten.



EFF :

ALL  33-48-11

Page 410
Nov 01/07
 
IAC 
R NOTE : It is necessary to refer to the match marks made during the
____
R removal procedure for the countersunk screw (11) installation
R in the correct position.

R (12) Make sure that the pin (13) engages in the bung (10).

**ON A/C ALL

Subtask 33-48-11-860-051

B. Preparation for the Test

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED
_______
BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

Subtask 33-48-11-865-054

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/UPPER 1LV U06

Subtask 33-48-11-710-050

D. Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the overhead panel 25VU: On the upper fuselage:


- put the switch 2LV BEACON - the upper beacon/strobe light 7LV
ON-OFF to the ON position. flashes (1 flash per second).

- put the switch 2LV BEACON - the upper beacon/strobe light 7LV
ON-OFF to the OFF position. goes off.



EFF :

ALL  33-48-11

Page 411
Nov 01/07
 
IAC 
5. Close-up
________

Subtask 33-48-11-410-052

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the access platform(s).

Subtask 33-48-11-862-055

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-48-11

Page 412
Nov 01/07
R  
IAC 
TASK 33-48-11-000-002

Removal of the Upper Beacon/Strobe Light 7LV from the Inside of the Fuselage

WARNING : ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE
_______
ENVIRONMENT.

NOTE : You can also remove the upper beacon/strobe light from the outside of
____
the fuselage (Ref. TASK 33-48-11-000-001).

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific stepladder 1.5 m (4 ft. 11 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

25-23-41-000-001 Removal of the Ceiling Panels

**ON A/C 001-012, 014-099,

33-48-11-991-004 Fig. 401

**ON A/C 101-199, 901-999,

33-48-11-991-004-A Fig. 401A



EFF :

ALL  33-48-11

Page 413
Nov 01/07
R  
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-48-11-860-050

A. Aircraft Maintenance Configuration

(1) Make sure that the switch 2LV BEACON ON-OFF on the overhead panel
25VU is in the OFF position.

(2) Make sure that the switch 4WL EMER EXIT LT OFF-ARM-ON on the overhead
panel 25VU is in the OFF position.

(3) Make sure that the pushbutton EMERG LIGHT on the FWD Attendant Panel
(FAP) 120RH is in the released position.

Subtask 33-48-11-865-051

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/UPPER 1LV U06

Subtask 33-48-11-010-053

C. Get Access

(1) Put the stepladder in position.

(2) Remove the center ceiling panel 241CC to get access to the upper
beacon/strobe light (Ref. TASK 25-23-41-000-001).

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-48-11-991-004)

**ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-48-11-991-004-A)



EFF :

ALL  33-48-11

Page 414
Nov 01/07
R  
IAC 
**ON A/C ALL

Subtask 33-48-11-020-052

A. Removal of the Upper Beacon/Strobe LIght 7LV

(1) Disconnect the electrical connector (1) from the light assembly (2).

(2) Put blanking caps on the disconnected electrical connectors.

(3) Loosen the screw (7), remove the attach ring (6) from the flange (3)
and discard the O-ring (4).

(4) Remove the movable part of the flange (3) together with the light
assembly (2).

(5) Remove the countersunk screws (5).

(6) Remove the light assembly (2) with the seal (12) from the flange (3).

(7) Discard the seal (12).



EFF :

ALL  33-48-11

Page 415
Nov 01/07
R  
IAC 
TASK 33-48-11-400-002

Installation of the Upper Beacon/Strobe Light 7LV from the Inside of the
Fuselage

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 07-001B


ELECTRICAL BONDING COATING (BLUE COLOR)
(Ref. 20-31-00)
Material No. 08-007 USA MIL-R-46082 TYPE II
SEALANT, HIGH TEMP. (Ref. 20-31-00)
Material No. 09-013 C Z-16.127
CORROSION INHIBITING BRUSH CONSISTENCY
(Ref. 20-31-00)

B. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

4 O-ring 33-48-04 01 -090


12 seal 33-48-11 01 -040
12 seal 33-48-11 01A-040



EFF :

ALL  33-48-11

Page 416
Nov 01/07
R  
IAC 
C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

20-28-00-912-004 Electrical Bonding of Components With Conductive


Bolts and Screws and Bonding Straps in the Fuselage
and in the Wings (this does not include the tanks)-
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
25-23-41-400-001 Installation of the Ceiling Panels

**ON A/C 001-012, 014-099,

33-48-11-991-004 Fig. 401

**ON A/C 101-199, 901-999,

33-48-11-991-004-A Fig. 401A

**ON A/C ALL

3. __________
Job Set-up

Subtask 33-48-11-860-054

A. Aircraft Maintenance Configuration

(1) Make sure that the stepladder is in position below the ceiling panel
241CC.

(2) Make sure that the ceiling panel 241CC is removed.

(3) Make sure that the switch 2LV BEACON ON-OFF on the overhead panel
25VU is in the OFF position.

(4) Make sure that the switch 4WL EMER EXIT LT OFF-ARM-ON on the overhead
panel 25VU is in the OFF position.

(5) Make sure that the pushbutton EMERG LIGHT on the FWD Attendant Panel
(FAP) 120RH is in the released position.



EFF :

ALL  33-48-11

Page 417
Nov 01/07
R  
IAC 
Subtask 33-48-11-865-055

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/UPPER 1LV U06

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-48-11-991-004)

**ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-48-11-991-004-A)

R **ON A/C ALL

R WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL MATERIALS


_______
R ONLY WITH A GOOD SUPPLY OF AIR.
R OBEY THE MANUFACTURERS INSTRUCTIONS.
R PUT ON PROTECTIVE CLOTHING.
R DO NOT GET THEM IN YOUR MOUTH.
R DO NOT SMOKE.
R DO NOT BREATHE THE GAS.
R THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT.
R GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.

**ON A/C 001-012, 014-099,

Subtask 33-48-11-420-052

A. Installation of the Upper Beacon/Strobe Light 7LV.

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.



EFF :

ALL  33-48-11

Page 418
Nov 01/07
 
IAC 
(3) Prepare the electrical bonding point at the flange (3) (Ref. TASK 20-
28-00-912-004).

R (4) Use the correct sequence when you tighten the countersunk screws (5).
R Install the light assembly (2) and the new seal (12) with the
R countersunk screws (5) on the flange (3).

(5) Apply SEALANTS (Material No. 09-013) to the heads of the countersunk
screws (5) (Ref. TASK 20-28-00-912-004) and let it dry.

(6) Apply PAINTS FOR DETAIL (INTERNAL AND EXTERN AL) (Material No. 07-
001B) to the head of the countersunk screw (5) which gives the
electrical bonding.

(7) Make sure that the bung (10) is correctly installed in the lens (9).

(8) Put the light assembly (2) together with the movable part of the
flange (3) in position.
R

R (9) Only on light with PN 2LA55010-00:


R

R (a) Make sure that the pin (13) engages correctly in the bung (10).

R (10) Install the V-clamp (6) with a new O-ring (4) and tighten the screw
(7).

R (11) Safety the screw (7) with BONDING AND ADHESIVE COMPOUNDS (Material
No. 08-007).

R (12) Remove the blanking caps from the electrical connectors.

R (13) Make sure that the electrical connectors are clean and in the correct
condition.

R (14) Connect the electrical connector (1) to the light assembly (2).


R

EFF :

001-012, 014-099,  33-48-11

Page 419
Nov 01/07
 
IAC 
**ON A/C 101-199, 901-999,

Subtask 33-48-11-420-052-A

A. Installation of the Upper Beacon/Strobe Light 7LV.

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Prepare the electrical bonding point at the flange (3) (Ref. TASK 20-
28-00-912-004).

R (4) Use the correct sequence when you tighten the countersunk screws (5).
R Install the light assembly (2) and the new seal (12) with the
R countersunk screws (5) on the flange (3).

(5) Apply SEALANTS (Material No. 09-013) to the heads of the countersunk
screws (5) (Ref. TASK 20-28-00-912-004) and let it dry.

(6) Apply PAINTS FOR DETAIL (INTERNAL AND EXTERN AL) (Material No. 07-
001B) to the head of the countersunk screw (5) which gives the
electrical bonding.

(7) Make sure that the bung (10) is correctly installed in the lens (9).

(8) Put the light assembly (2) together with the movable part of the
flange (3) in position.
R

R (9) Make sure that the pin (13) engages correctly in the bung (10).

R (10) Install the V-clamp (6) with a new O-ring (4) and tighten the screw
(7).

R (11) Safety the screw (7) with BONDING AND ADHESIVE COMPOUNDS (Material
No. 08-007).

R (12) Remove the blanking caps from the electrical connectors.

R (13) Make sure that the electrical connectors are clean and in the correct
condition.

R (14) Connect the electrical connector (1) to the light assembly (2).


R

EFF :

101-199, 901-999,  33-48-11

Page 420
Nov 01/07
 
IAC 
**ON A/C ALL

Subtask 33-48-11-860-053

B. Preparation for the Test

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED
_______
BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

Subtask 33-48-11-865-056

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/UPPER 1LV U06

Subtask 33-48-11-710-051

D. Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the overhead panel 25VU: On the upper fuselage:


- put the switch 2LV BEACON - the upper beacon/strobe light 7LV
ON-OFF to the ON position. flashes (1 flash per second).

- put the swich 2LV BEACON ON-OFF - the upper beacon/strobe light 7LV
to the OFF position. goes off.



EFF :

ALL  33-48-11

Page 421
Nov 01/07
R  
IAC 
5. Close-up
________

Subtask 33-48-11-410-051

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the center ceiling panel (Ref. TASK 25-23-41-400-001).

(3) Remove the stepladder.

Subtask 33-48-11-862-054

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).


R

EFF :

ALL  33-48-11

Page 422
Nov 01/07
 
IAC 
TASK 33-48-11-000-003

Removal of the Flash Tube Assembly of the Upper Beacon Light

WARNING : ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE
_______
ENVIRONMENT.

WARNING : DO NOT TOUCH THE STROBE LIGHTS FOR AT LEAST 5 MINUTES AFTER
_______
OPERATION. THE STROBE LIGHT WILL STILL BE HOT.

WARNING : DO NOT REMOVE THE STROBE LIGHT FOR AT LEAST TEN MINUTES AFTER YOU
_______
DE-ENERGIZE THE ELECTRICAL CIRCUITS. THE HIGH VOLTAGE ELECTRICAL
CURRENT IN THE CAPACITOR OF THE STROBE LIGHT IS DANGEROUS.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific 1 ACCESS PLATFORM 6M (20 FT)
No specific 1 WARNING NOTICE

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-48-11-991-006 Fig. 402

3. __________
Job Set-up

Subtask 33-48-11-941-053

A. Safety Precautions

(1) Put a WARNING NOTICE on panel 25VU to tell persons not to operate the
strobe lights or the navigation lights.



EFF :

ALL  33-48-11

Page 423
Nov 01/07
R  
IAC 
Subtask 33-48-11-865-059

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/UPPER 1LV U06

Subtask 33-48-11-010-057

C. Get Access

(1) Make sure that the switch 2LV BEACON ON-OFF on the overhead panel
25VU is in the OFF position.

(2) Put the ACCESS PLATFORM 6M (20 FT) in position.

4. Procedure
_________

(Ref. Fig. 402/TASK 33-48-11-991-006)

Subtask 33-48-11-020-054

A. Removal of the Flash Tube Assembly of the Upper Beacon/Strobe Light 7LV

(1) Remove and discard the bung (1).

(2) Remove the countersunk screws (2) from the structure (3).

(3) Remove the lens (9) and discard the seal (8).

(4) Remove the countersunk screws (6) from the light assembly (4).

(5) Lift the flash tube assembly (7) until you can see the electrical
connectors (5).

(6) Disconnect the electrical connectors (5) from the light assembly (4).

(7) Remove the flash tube assembly (7) from the light assembly (4).

(8) Put blanking caps on the disconnected electrical connectors.


R

EFF :

ALL  33-48-11

Page 424
Nov 01/07
 
IAC 
R Flash Tube Assembly of the Upper Beacon Light
Figure 402/TASK 33-48-11-991-006



EFF :

ALL  33-48-11

Page 425
Nov 01/07
 
IAC 
TASK 33-48-11-400-003

Installation of the Flash Tube Assembly of the Upper Beacon Light

WARNING : ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE
_______
ENVIRONMENT.

WARNING : DO NOT TOUCH THE STROBE LIGHTS FOR AT LEAST 5 MINUTES AFTER
_______
OPERATION. THE STROBE LIGHT WILL STILL BE HOT.

WARNING : DO NOT REMOVE THE STROBE LIGHT FOR AT LEAST TEN MINUTES AFTER YOU
_______
DE-ENERGIZE THE ELECTRICAL CIRCUITS. THE HIGH VOLTAGE ELECTRICAL
CURRENT IN THE CAPACITOR OF THE STROBE LIGHT IS DANGEROUS.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific 1 WARNING NOTICE

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 08-013 USA MIL-R-46082 TYPE I MIL-S-22473


SEALANT, ANAEROBIC (Ref. 20-31-00)
Material No. 09-013 C Z-16.127
CORROSION INHIBITING BRUSH CONSISTENCY
(Ref. 20-31-00)



EFF :

ALL  33-48-11

Page 426
Feb 01/07
R  
IAC 
C. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

1 bung 33-48-11 01 -020


1 bung 33-48-11 01A-020
7 TUBE ASSEMBLY-FLASH 33-48-11 01 -060
7 TUBE ASSEMBLY-FLASH 33-48-11 01A-060
8 seal 33-48-11 01 -030
8 seal 33-48-11 01A-030

D. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R 20-21-11-911-001 Tightening Torques for Standard Threaded Fasteners


20-28-00-912-004 Electrical Bonding of Components With Conductive
Bolts and Screws and Bonding Straps in the Fuselage
and in the Wings (this does not include the tanks)-
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
33-48-11-991-006 Fig. 402

3. __________
Job Set-up

Subtask 33-48-11-941-054

A. Safety Precautions

(1) Make sure that the WARNING NOTICE is in position on panel 25VU to
tell persons not to operate the strobe lights or the navigation
lights.



EFF :

ALL  33-48-11

Page 427
Nov 01/07
 
IAC 
Subtask 33-48-11-860-056

B. Aircraft Maintenance Configuration

(1) Make sure that the parts retained from the removed component are
clean and in the correct condition.

(2) Make sure that the switch 2LV BEACON ON-OFF on the overhead panel
25VU is in the OFF position.

Subtask 33-48-11-865-060

C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/UPPER 1LV U06

4. Procedure
_________

(Ref. Fig. 402/TASK 33-48-11-991-006)

R WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL MATERIALS


_______
R ONLY WITH A GOOD SUPPLY OF AIR.
R OBEY THE MANUFACTURERS INSTRUCTIONS.
R PUT ON PROTECTIVE CLOTHING.
R DO NOT GET THEM IN YOUR MOUTH.
R DO NOT SMOKE.
R DO NOT BREATHE THE GAS.
R THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT.
R GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.

Subtask 33-48-11-420-054

A. Installation of the Flash Tube Assembly of the Upper Beacon/Strobe Light


7LV

R NOTE : For the torque values that you must use for the screws, refer to
____
R (Ref. TASK 20-21-11-911-001).

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Remove the blanking caps from the electrical connectors.


R

EFF :

ALL  33-48-11

Page 428
Nov 01/07
 
IAC 
(4) Make sure that the electrical connectors are clean and in the correct
condition.

(5) Connect the electrical connectors (5) to the light assembly (4).

(6) Put the new TUBE ASSEMBLY-FLASH (7) on the light assembly (4).

R (7) Use the correct sequence when you tighten the countersunk screws (6).
R Apply BONDING AND ADHESIVE COMPOUNDS (Material No. 08-013) to the
R threads of the countersunk screws (6), then install the screws and
tighten.

(8) Install a new bung (1).

(9) Install the lens (9) with a new seal (8).

R (10) Use the correct sequence when you tighten the countersunk screws (2).
R Apply BONDING AND ADHESIVE COMPOUNDS (Material No. 08-013) to the
R threads of the countersunk screws (2), then install the screws and
tighten.

R NOTE : It is necessary to refer to the match marks made during the


____
R removal procedure for the screw installation in the correct
R position.

(11) Apply SEALANTS (Material No. 09-013) to the heads of the countersunk
screws (2) (Ref. TASK 20-28-00-912-004) and let it dry.

Subtask 33-48-11-860-057

B. Preparation for the Test

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED
_______
BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

Subtask 33-48-11-865-061

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/UPPER 1LV U06



EFF :

ALL  33-48-11

Page 429
Nov 01/07
 
IAC 
Subtask 33-48-11-710-053

D. Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the overhead panel 25VU: On the upper fuselage:


- put the switch 2LV BEACON - the upper beacon/strobe light 7LV
ON-OFF in the ON position. flashes (1 flash per second).

- put the switch 2LV BEACON - the upper beacon/strobe light 7LV
ON-OFF in the OFF position. goes off.

5. Close-up
________

Subtask 33-48-11-410-053

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

Subtask 33-48-11-862-056

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).

Subtask 33-48-11-942-054

C. Removal of Equipment

(1) Remove the warning notice(s).

(2) Remove the access platform(s).

(3) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.



EFF :

ALL  33-48-11

Page 430
Nov 01/07
R  
IAC 
LIGHT - BEACON,LOWER (6LV) - REMOVAL/INSTALLATION
_________________________________________________

TASK 33-48-12-000-001

Removal of the Lower Beacon/Strobe Light 6LV from the Fuselage Outside

WARNING : ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE
_______
ENVIRONMENT.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-099,

33-48-12-991-001 Fig. 401

R **ON A/C 101-199, 901-999,

33-48-12-991-001-A Fig. 401A



EFF :

ALL  33-48-12

Page 401
Feb 01/07
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-48-12-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/LOWER 5LV U03

Subtask 33-48-12-869-050

B. Make sure that the switch 2LV BEACON ON-OFF on the overhead panel 25VU is
in the OFF position.

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-48-12-991-001)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-48-12-991-001-A)

**ON A/C ALL

Subtask 33-48-12-020-051

A. Removal of the Lower Beacon/Strobe Light 6LV

(1) Remove the screws (4) from the lens (6).

(2) Remove the lens (6) and discard the seal (7).

(3) Remove the screws (3) and (9) from the mount plate (8).



EFF :

ALL  33-48-12

Page 402
Feb 01/07
 
IAC 
R Lower Beacon/Strobe Light
Figure 401/TASK 33-48-12-991-001



EFF :

001-012, 014-099,  33-48-12

Page 403
Nov 01/07
 
IAC 
R Lower Beacon/Strobe Light
Figure 401A/TASK 33-48-12-991-001-A



EFF :

101-199, 901-999,  33-48-12

Page 404
Nov 01/07
 
IAC 
(4) Remove the light assembly (2) until the electrical connector (1) is
visible.

(5) Disconnect the electrical connector (1) from the light assembly (2).

(6) Put blanking caps on the disconnected electrical connectors.

(7) Remove the light assembly (2) with the seal (10)

(8) Discard the seal (10).



EFF :

ALL  33-48-12

Page 405
Aug 01/06
R  
IAC 
TASK 33-48-12-400-001

Installation of the Lower Beacon/Strobe Light 6LV from the Fuselage Outside

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 07-001B


ELECTRICAL BONDING COATING (BLUE COLOR)
(Ref. 20-31-00)
Material No. 09-013 C Z-16.127
CORROSION INHIBITING BRUSH CONSISTENCY
(Ref. 20-31-00)

B. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

R 3 seal 33-48-12 01 -030


R 7 seal 33-48-12 01 -030
R 10 seal 33-48-12 01 -040

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R 20-21-11-911-001 Tightening Torques for Standard Threaded Fasteners


20-28-00-912-004 Electrical Bonding of Components With Conductive
Bolts and Screws and Bonding Straps in the Fuselage
and in the Wings (this does not include the tanks)-
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power



EFF :

ALL  33-48-12

Page 406
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-099,

33-48-12-991-001 Fig. 401

R **ON A/C 101-199, 901-999,

33-48-12-991-001-A Fig. 401A

**ON A/C ALL

3. __________
Job Set-up

Subtask 33-48-12-869-051

A. Make sure that the switch 2LV BEACON ON-OFF on the overhead panel 25VU is
in the OFF position.

Subtask 33-48-12-865-051

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/LOWER 5LV U03

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-48-12-991-001)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-48-12-991-001-A)



EFF :

ALL  33-48-12

Page 407
Feb 01/07
 
IAC 
R **ON A/C ALL

R WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL MATERIALS


_______
R ONLY WITH A GOOD SUPPLY OF AIR.
R OBEY THE MANUFACTURERS INSTRUCTIONS.
R PUT ON PROTECTIVE CLOTHING.
R DO NOT GET THEM IN YOUR MOUTH.
R DO NOT SMOKE.
R DO NOT BREATHE THE GAS.
R THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT.
R GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.

**ON A/C 001-012, 014-099,

Subtask 33-48-12-420-050

A. Installation of the Lower Beacon/Strobe Light 6LV

R NOTE : For the torque values that you must use for the screws, refer to
____
R (Ref. TASK 20-21-11-911-001).

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Prepare the electrical bonding point at the mount plate (8)
(Ref. TASK 20-28-00-912-004).

(4) Remove the blanking caps from the electrical connectors.

(5) Make sure that the electrical connectors are clean and in the correct
condition.

(6) Connect the electrical connector (1) to the light assembly (2).

R (7) Use the correct sequence when you tighten the screws (3) and (9).
R Install the light assembly (2) and the new seal (10) with the screws
R (3) and (9) on the mount plate (8).

(8) Apply SEALANTS (Material No. 09-013) to the heads of the screws (9)
and let it dry.

(9) Apply PAINTS FOR DETAIL (INTERNAL AND EXTERN AL) (Material No. 07-
001B) to the sealant of the srews (9).


R

EFF :

ALL  33-48-12

Page 408
Nov 01/07
 
IAC 
R (10) On all lights, but not on PN 2LA55010-00:

(a) Remove the lens drain plug (5) if installed.

R NOTE : It is necessary to remove the lens drain plug (5) to make


____
R sure that no condensed water stays in the lens (6).

R (b) Use the correct sequence when you tighten the screws (4).
R Install the lens (6) with a new seal (7) and the screws (4) and
R tighten.

(11) On lights with PN 2LA55010-00:

(a) Make sure that the bung (5) is removed.

R NOTE : It is necessary to remove the bung (5) to make sure that


____
R no condensed water stays in the lens (6).

R (b) Use the correct sequence when you tighten the screws (4).
R Install the lens (6) with a new seal (7) and the screws (4) and
R tighten.

**ON A/C 101-199, 901-999,

Subtask 33-48-12-420-050-A

A. Installation of the Lower Beacon/Strobe Light 6LV

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Prepare the electrical bonding point at the mount plate (8)
(Ref. TASK 20-28-00-912-004).

(4) Remove the blanking caps from the electrical connectors.

(5) Make sure that the electrical connectors are clean and in the correct
condition.

(6) Connect the electrical connector (1) to the light assembly (2).

R (7) Use the correct sequence when you tighten the screws (3) and (9).
R Install the light assembly (2) and the new seal (10) with the screws
R (3) and (9) on the mount plate (8).

(8) Apply SEALANTS (Material No. 09-013) to the heads of the screws (9)
and let it dry.

(9) Apply PAINTS FOR DETAIL (INTERNAL AND EXTERN AL) (Material No. 07-
001B) to the sealant of the srews (9).



EFF :

ALL  33-48-12

Page 409
Nov 01/07
 
IAC 
(10) Make sure that the bung (5) is removed.

R NOTE : It is necessary to remove the bung (5) to make sure that no


____
R condensed water stays in the lens (6).

R (11) Use the correct sequence when you tighten the screws (4).
R Install the lens (6) with a new seal (3) and the screws (4) and
R tighten.

**ON A/C ALL

Subtask 33-48-12-865-053

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/LOWER 5LV U03

Subtask 33-48-12-710-051

C. Do this test

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. Energize the aircraft electrical


circuits (Ref. TASK 24-41-00-861-
002).

2. On the overhead panel 25VU: On the lower fuselage:


- put the switch 2LV BEACON - the lower beacon/strobe light 6LV
ON-OFF to the ON position. flashes (1 flash per second).

- put the switch 2LV BEACON - the lower beacon/strobe light 6LV
ON-OFF to the OFF position. goes off.

5. Close-up
________

Subtask 33-48-12-860-050

A. Put the aircraft back to the serviceable condition.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-48-12

Page 410
Nov 01/07
 
IAC 
TASK 33-48-12-700-001

Test of the Lower Beacon/Strobe Light 6LV

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-48-12-861-050

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-48-12-865-052

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/LOWER 5LV U03



EFF :

ALL  33-48-12

Page 411
Feb 01/07
R  
IAC 
INTENTIONALLY BLANK


R



 33-48-12

Page 412
Aug 01/06
 
IAC 
R **ON A/C ALL

4. Procedure
_________

Subtask 33-48-12-710-050

A. Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the overhead panel 25VU: On the lower fuselage:


- put the switch BEACON 2LV to - the lower beacon/strobe light 6LV
the ON position. flashes (1 flash per second).

- put the switch BEACON 2LV to - the lower beacon/strobe light 6LV
the OFF position. goes off.

5. Close-up
________

Subtask 33-48-12-410-050

A. Make sure that the work area is clean and clear of tool(s) and other
items.

Subtask 33-48-12-862-050

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-48-12

Page 413
May 01/06
 
IAC 
R TASK 33-48-12-000-002

R Removal of the Flash Tube Assembly of the Lower Beacon Light

R WARNING : ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE
_______
R ENVIRONMENT.

R WARNING : DO NOT TOUCH THE STROBE LIGHTS FOR AT LEAST 5 MINUTES AFTER
_______
R OPERATION. THE STROBE LIGHT WILL STILL BE HOT.

R WARNING : DO NOT REMOVE THE STROBE LIGHT FOR AT LEAST TEN MINUTES AFTER YOU
_______
R DE-ENERGIZE THE ELECTRICAL CIRCUITS. THE HIGH VOLTAGE ELECTRICAL
R CURRENT IN THE CAPACITOR OF THE STROBE LIGHT IS DANGEROUS.

R 1. __________________
Reason for the Job

R Self Explanatory

R 2. ______________________
Job Set-up Information

R A. Fixtures, Tools, Test and Support Equipment

R -------------------------------------------------------------------------------
R REFERENCE QTY DESIGNATION
R -------------------------------------------------------------------------------

R No specific blanking caps


R No specific circuit breaker(s) safety clip(s)
R No specific 1 WARNING NOTICE

R B. Referenced Information

R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------

R 33-48-12-991-002 Fig. 402

R 3. __________
Job Set-up

R Subtask 33-48-12-941-050

R A. Safety Precautions

R (1) Put a WARNING NOTICE on panel 25VU to tell persons not to operate the
R strobe lights or the navigation lights.



EFF :

ALL  33-48-12

Page 414
May 01/06
 
IAC 
Subtask 33-48-12-865-056

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/LOWER 5LV U03

Subtask 33-48-12-010-051

C. Make sure that the switch 2LV BEACON ON-OFF on the overhead panel 25VU is
in the OFF position.

4. Procedure
_________

(Ref. Fig. 402/TASK 33-48-12-991-002)

Subtask 33-48-12-020-052

A. Removal of the Flash Tube Assembly of the Lower Beacon/Strobe Light 6LV

(1) Remove the countersunk screws (2) from the structure (9).

(2) Remove the lens (4) and discard the seal (5).

(3) Remove the countersunk screws (1) from the light assembly (8).

(4) Lift the light assembly (8) until you can see the electrical
connectors (7).

(5) Disconnect the electrical connectors (7) from the light assembly (8).

(6) Remove the flash tube assembly (6) from the light assembly (8).

(7) Put blanking caps on the disconnected electrical connectors.



EFF :

ALL  33-48-12

Page 415
Nov 01/07
R  
IAC 
R Flash Tube Assembly of the Lower Beacon Light
Figure 402/TASK 33-48-12-991-002



EFF :

ALL  33-48-12

Page 416
Nov 01/07
 
IAC 
R TASK 33-48-12-400-002

R Installation of the Flash Tube Assembly of the Lower Beacon Light

R WARNING : ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE
_______
R ENVIRONMENT.

R WARNING : DO NOT TOUCH THE STROBE LIGHTS FOR AT LEAST 5 MINUTES AFTER
_______
R OPERATION. THE STROBE LIGHT WILL STILL BE HOT.

R WARNING : DO NOT REMOVE THE STROBE LIGHT FOR AT LEAST TEN MINUTES AFTER YOU
_______
R DE-ENERGIZE THE ELECTRICAL CIRCUITS. THE HIGH VOLTAGE ELECTRICAL
R CURRENT IN THE CAPACITOR OF THE STROBE LIGHT IS DANGEROUS.

R 1. __________________
Reason for the Job

R Self Explanatory

R 2. ______________________
Job Set-up Information

R A. Fixtures, Tools, Test and Support Equipment

R -------------------------------------------------------------------------------
R REFERENCE QTY DESIGNATION
R -------------------------------------------------------------------------------

R No specific 1 WARNING NOTICE

R B. Consumable Materials

R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------

R Material No. 08-013 USA MIL-R-46082 TYPE I MIL-S-22473


R SEALANT, ANAEROBIC (Ref. 20-31-00)
R Material No. 09-013 C Z-16.127
R CORROSION INHIBITING BRUSH CONSISTENCY
R (Ref. 20-31-00)



EFF :

ALL  33-48-12

Page 417
May 01/06
 
IAC 
R C. Expendable Parts

R -------------------------------------------------------------------------------
R FIG.ITEM |DESIGNATION |IPC-CSN
R -------------------------------------------------------------------------------

R 5 seal 33-48-12 02 -030


R 6 TUBE ASSEMBLY-FLASH 33-48-12 02 -060

R D. Referenced Information

R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------

R 20-21-11-911-001 Tightening Torques for Standard Threaded Fasteners


R 20-28-00-912-004 Electrical Bonding of Components With Conductive
R Bolts and Screws and Bonding Straps in the Fuselage
R and in the Wings (this does not include the tanks)-
R 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
R External Power
R 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
R from the External Power
R 33-48-12-991-002 Fig. 402

R 3. __________
Job Set-up

R Subtask 33-48-12-941-051

R A. Safety Precautions

R (1) Make sure that the WARNING NOTICE is in position on panel 25VU to
R tell persons not to operate the strobe lights or the navigation
R lights.

R Subtask 33-48-12-860-053

R B. Aircraft Maintenance Configuration

R (1) Make sure that the parts retained from the removed component are
R clean and in the correct condition.

R (2) Make sure that the switch 2LV BEACON ON-OFF on the overhead panel
R 25VU is in the OFF position.



EFF :

ALL  33-48-12

Page 418
May 01/06
 
IAC 
Subtask 33-48-12-865-057

C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/LOWER 5LV U03

4. Procedure
_________

(Ref. Fig. 402/TASK 33-48-12-991-002)

R WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL MATERIALS


_______
R ONLY WITH A GOOD SUPPLY OF AIR.
R OBEY THE MANUFACTURERS INSTRUCTIONS.
R PUT ON PROTECTIVE CLOTHING.
R DO NOT GET THEM IN YOUR MOUTH.
R DO NOT SMOKE.
R DO NOT BREATHE THE GAS.
R THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT.
R GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.

Subtask 33-48-12-420-051

A. Installation of the Flash Tube Assembly of the Lower Beacon/Strobe Light


6LV

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Remove the blanking caps from the electrical connectors.

(4) Make sure that the electrical connectors are clean and in the correct
condition.

(5) Connect the electrical connectors (7) to the light assembly (8).

(6) Put the new TUBE ASSEMBLY-FLASH (6) on the light assembly (8).
R

R (7) Use the correct sequence when you tighten the countersunk screws (1).
R Apply BONDING AND ADHESIVE COMPOUNDS (Material No. 08-013) to the
R threads of the countersunk screws (1), then install the countersunk
R screws and tighten. (Ref. TASK 20-21-11-911-001)



EFF :

ALL  33-48-12

Page 419
Nov 01/07
 
IAC 
(8) Make sure that the bung (3) is removed from the lens (4) to drain the
condensation.

(9) Install the lens (4) with a new seal (5).


R

R (10) Use the correct sequence when you tighten the countersunk screws (2).
R Apply BONDING AND ADHESIVE COMPOUNDS (Material No. 08-013) to the
R threads of the countersunk screws (2), then install the countersunk
R screws and tighten. (Ref. TASK 20-21-11-911-001)

(11) Apply SEALANTS (Material No. 09-013) to the heads of the countersunk
screws (2) (Ref. TASK 20-28-00-912-004) and let it dry.

Subtask 33-48-12-861-052

B. Preparation for the Test

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002)

Subtask 33-48-12-865-058

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/BEACON/LOWER 5LV U03

Subtask 33-48-12-710-053

D. Do this test

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the overhead panel 25VU: On the lower fuselage:


- put the switch 2LV BEACON - the lower beacon/strobe light 6LV
ON-OFF in the ON position. flashes (1 flash per second).

- put the switch 2LV BEACON - the lower beacon/strobe light 6LV
ON-OFF in the OFF position. goes off.



EFF :

ALL  33-48-12

Page 420
Nov 01/07
 
IAC 
5. Close-up
________

Subtask 33-48-12-410-052

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

Subtask 33-48-12-862-051

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).

Subtask 33-48-12-942-050

C. Removal of Equipment

(1) Remove the warning notice(s).

(2) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.



EFF :

ALL  33-48-12

Page 421
Aug 01/06
R  
IAC 
LIGHT - STROBE, TAIL CONE (19LV) - REMOVAL/INSTALLATION
_______________________________________________________

TASK 33-48-13-000-001

Removal of the Tail Cone Strobe-Light (19LV)

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific access platform 3.5 m (11 ft. 6 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-41-15-000-001 Removal of the Tail Navigation Light 15LA


33-41-15-000-002 Removal of the Lamp(s) of the Tail Navigation Light
15LA

**ON A/C 001-012, 014-099,

33-48-13-991-003 Fig. 401

R **ON A/C 101-199, 901-999,

33-48-13-991-003-A Fig. 401A



EFF :

ALL  33-48-13

Page 401
Feb 01/07
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-48-13-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
121VU APU/APU/CTL 2KD L42
121VU APU/ECB/SPLY 1KD L41
122VU LIGHTING/EXT LT/NAV1/AND LOGO/LT 1LA T03
122VU LIGHTING/EXT LT/NAV2/AND LOGO/LT 2LA T02
122VU LIGHTING/WING/STROBE 10LV V05

**ON A/C 001-012, 014-099,

Subtask 33-48-13-010-050

B. Get Access
(Ref. Fig. 401/TASK 33-48-13-991-003)

(1) Put the access platform in position at the APU tail cone exhaust-area
Zone 317.

(2) Remove the tail navigation light (15LA) (3) (Ref. TASK 33-41-15-000-
001).

R **ON A/C 101-199, 901-999,

Subtask 33-48-13-010-050-A

B. Get Access
(Ref. Fig. 401A/TASK 33-48-13-991-003-A)

(1) Put the access platform in position at the APU tail cone exhaust-area
Zone 317.

(2) Remove the lens from the tail navigation light (15LA) (3) (Ref. TASK
33-41-15-000-002).



EFF :

ALL  33-48-13

Page 402
Feb 01/07
 
IAC 
R Tail Cone Strobe Light
R Figure 401/TASK 33-48-13-991-003


R

EFF :

001-012, 014-099,  33-48-13

Page 403
Aug 01/06
 
IAC 
Tail Cone Strobe Light
Figure 401A/TASK 33-48-13-991-003-A


R

EFF :

101-199, 901-999,  33-48-13

Page 404
Feb 01/07
 
IAC 
**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-48-13-991-003)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-48-13-991-003-A)

**ON A/C ALL

Subtask 33-48-13-020-050

A. Removal of the Tail Cone Strobe-Light (19LV)

WARNING : DO NOT REMOVE THE STROBE LIGHT FOR AT LEAST TEN MINUTES AFTER
_______
YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS. THE HIGH VOLTAGE
ELECTRICAL CURRENT IN THE CAPACITOR OF THE STROBE LIGHT IS
DANGEROUS.

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2


_______
MINUTES AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

WARNING : BE CAREFUL IF YOU TOUCH THE STROBE LIGHT WITH THE COVER REMOVED
_______
AND THE POWER APPLIED. SOME COMPONENTS HAVE DANGEROUS VOLTAGES.

WARNING : DO NOT TOUCH THE STROBE LIGHTS FOR AT LEAST 5 MINUTES AFTER
_______
OPERATION. THE STROBE LIGHT WILL STILL BE HOT.

(1) Remove the screws (1), the washers (2) and the tail cone strobe-light
(4) from the tail navigation light (3).



EFF :

ALL  33-48-13

Page 405
Feb 01/07
 
IAC 
TASK 33-48-13-400-001

Installation of the Tail Cone Strobe-Light (19LV)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R Material No. 05-002 USA MIL-PRF-8116


PUTTY, ZINC CHROMATE GENERAL PURPOSE (Ref. 20-31-00)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-41-15-400-001 Installation of the Tail Navigation Light 15LA


33-41-15-400-002 Installation of the Lamp(s) of the Tail Navigation
Light 15LA
33-48-00-710-002 Operational Test of the Anti-Collision/Strobe
Lighting

**ON A/C 001-012, 014-099,

33-48-13-991-003 Fig. 401

**ON A/C 101-199, 901-999,

33-48-13-991-003-A Fig. 401A



EFF :

ALL  33-48-13

Page 406
Feb 01/08
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-48-13-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
121VU APU/APU/CTL 2KD L42
121VU APU/ECB/SPLY 1KD L41
122VU LIGHTING/EXT LT/NAV1/AND LOGO/LT 1LA T03
122VU LIGHTING/EXT LT/NAV2/AND LOGO/LT 2LA T02
122VU LIGHTING/WING/STROBE 10LV V05

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-48-13-991-003)

R **ON A/C 101-199, 901-999,

(Ref. Fig. 401A/TASK 33-48-13-991-003-A)

**ON A/C ALL

Subtask 33-48-13-910-050

A. Preparation for Installation

(1) Make sure that the parts retained from the removed component are
clean and in the correct condition.

(2) Clean the component interface and/or the adjacent area.

(3) Do an inspection of the component interface and/or the adjacent area.



EFF :

ALL  33-48-13

Page 407
Feb 01/07
 
IAC 
Subtask 33-48-13-420-051

B. Installation of the Tail Cone Strobe-Light (19LV)

(1) Apply SPECIAL MATERIALS (Material No. 05-002) to the washers (2) and
the screws (1).

(2) Install the tail cone strobe-light (4) in the tail navigation light
(3) with the washers (2) and the screws (1).

**ON A/C 001-012, 014-099,

Subtask 33-48-13-410-051

C. Close Access
(Ref. Fig. 401/TASK 33-48-13-991-003)

(1) Install the tail navigation light (15LA) (3) (Ref. TASK 33-41-15-400-
001).

(2) Make sure that the work area is clean and clear of tool(s) and other
items.

R **ON A/C 101-199, 901-999,

Subtask 33-48-13-410-051-A

C. Close Access
(Ref. Fig. 401A/TASK 33-48-13-991-003-A)

(1) Install the lens of the tail navigation light (15LA) (3) (Ref. TASK
33-41-15-400-002).

(2) Make sure that the work area is clean and clear of tool(s) and other
items.

**ON A/C ALL

Subtask 33-48-13-865-056

D. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):

(1) 1KD, 2KD, 1LA, 2LA, 10LV



EFF :

ALL  33-48-13

Page 408
Feb 01/07
 
IAC 
Subtask 33-48-13-710-050

E. Do the test of the tail cone strobe-light (19LV)

WARNING : DO NOT LOOK DIRECTLY AT THE LIGHT FLASH DURING THE TEST.
_______
SUPPLY A COVER, OR SHIELD, TO GIVE PROTECTION FROM THE LIGHT
FLASH TO PERSONS IN THE TEST AREA.

(1) Do the operational test of the anticollision/strobe light system


(Ref. TASK 33-48-00-710-002).

5. Close-up
________

Subtask 33-48-13-410-050

A. Close Access

(1) Put the system back to the serviceable condition.

(2) Remove the access platform(s).



EFF :

ALL  33-48-13

Page 409
Feb 01/07
R  
IAC 
R TASK 33-48-13-960-002

R Replacement of the Strobe-Light Flash-Tube Assembly

R WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
R YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

R 1. __________________
Reason for the Job

R Self Explanatory

R 2. ______________________
Job Set-up Information

R A. Fixtures, Tools, Test and Support Equipment

R -------------------------------------------------------------------------------
R REFERENCE QTY DESIGNATION
R -------------------------------------------------------------------------------

R No specific circuit breaker(s) safety clip(s)


R No specific access platform 3.5 m (11 ft. 6 in.)

R B. Expendable Parts

R -------------------------------------------------------------------------------
R FIG.ITEM |DESIGNATION |IPC-CSN
R -------------------------------------------------------------------------------

R 3 gasket 33-48-13 01 -020


R 5 flash tube assembly 33-48-13 01 -040

R C. Referenced Information

R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------

R 33-41-15-000-002 Removal of the Lamp(s) of the Tail Navigation Light


R 15LA
R 33-41-15-400-002 Installation of the Lamp(s) of the Tail Navigation
R Light 15LA
R 33-48-00-710-002 Operational Test of the Anti-Collision/Strobe
R Lighting
R 33-48-13-991-004 Fig. 402



EFF :

ALL  33-48-13

Page 410
Nov 01/06
 
IAC 
R 3. __________
Job Set-up

R Subtask 33-48-13-865-054

R A. Open, safety and tag this(these) circuit breaker(s):

R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R 121VU APU/APU/CTL 2KD L42
R 121VU APU/ECB/SPLY 1KD L41
R 122VU LIGHTING/EXT LT/NAV1/AND LOGO/LT 1LA T03
R 122VU LIGHTING/EXT LT/NAV2/AND LOGO/LT 2LA T02
R 122VU LIGHTING/WING/STROBE 10LV V05

R Subtask 33-48-13-010-052

R B. Get Access

R (1) Put the access platform in position at the APU tail cone exhaust-area
R Zone 317.

R (2) Remove the lens from the tail navigation light (15LA) (Ref. TASK 33-
R 41-15-000-002).

R 4. Procedure
_________

R (Ref. Fig. 402/TASK 33-48-13-991-004)

R Subtask 33-48-13-960-051

R A. Replacement of the Strobe-Light Flash-Tube Assembly

R WARNING : DO NOT REMOVE THE STROBE LIGHT FOR AT LEAST TEN MINUTES AFTER
_______
R YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS. THE HIGH VOLTAGE
R ELECTRICAL CURRENT IN THE CAPACITOR OF THE STROBE LIGHT IS
R DANGEROUS.

R WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2


_______
R MINUTES AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

R WARNING : BE CAREFUL IF YOU TOUCH THE STROBE LIGHT WITH THE COVER REMOVED
_______
R AND THE POWER APPLIED. SOME COMPONENTS HAVE DANGEROUS VOLTAGES.

R WARNING : DO NOT TOUCH THE STROBE LIGHTS FOR AT LEAST 5 MINUTES AFTER
_______
R OPERATION. THE STROBE LIGHT WILL STILL BE HOT.



EFF :

ALL  33-48-13

Page 411
Nov 01/06
 
IAC 
R Replacement of the Strobe-Light Flash-Tube Assembly
R Figure 402/TASK 33-48-13-991-004



EFF :

ALL  33-48-13

Page 412
Nov 01/06
 
IAC 
R (1) Remove the screws (1) and the lens (2).

R (2) Remove and discard the gasket (3).

R CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
R THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF
R THE LAMP.
R IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
R LINT-FREE CLOTH.

R (3) Remove the screws (4) and discard the flash tube assembly (5).

R (4) Install the new flash tube assembly (5) with the screws (4).

R (5) Install the new gasket (3) and the lens (2) with the screws (1).

R Subtask 33-48-13-410-052

R B. Close Access

R (1) Install the lens of the tail navigation light (15LA) (Ref. TASK 33-
R 41-15-400-002).

R (2) Make sure that the work area is clean and clear of tool(s) and other
R items.

R Subtask 33-48-13-865-055

R C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
R breaker(s):

R (1) 1KD, 2KD, 1LA, 2LA, 10LV

R Subtask 33-48-13-710-052

R D. Do the test of the tail cone strobe-light (19LV)

R WARNING : DO NOT LOOK DIRECTLY AT THE LIGHT FLASH DURING THE TEST.
_______
R SUPPLY A COVER, OR SHIELD, TO GIVE PROTECTION FROM THE LIGHT
R FLASH TO PERSONS IN THE TEST AREA.

R (1) Do the operational test of the anticollision/strobe light system


R (Ref. TASK 33-48-00-710-002).



EFF :

ALL  33-48-13

Page 413
Nov 01/06
 
IAC 
R 5. Close-up
________

R Subtask 33-48-13-410-053

R A. Close Access

R (1) Put the system back to the serviceable condition.

R (2) Remove the access platform(s).



EFF :

ALL  33-48-13

Page 414
Nov 01/06
 
IAC 
LIGHT - STROBE, WING TIP (16LV,17LV) - REMOVAL/INSTALLATION
___________________________________________________________

TASK 33-48-14-000-001

Removal of the Strobe Light

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

WARNING : DO NOT TOUCH THE STROBE LIGHTS FOR AT LEAST 5 MINUTES AFTER
_______
OPERATION. THE STROBE LIGHT WILL STILL BE HOT.

WARNING : DO NOT REMOVE THE STROBE LIGHT FOR AT LEAST TEN MINUTES AFTER YOU
_______
DE-ENERGIZE THE ELECTRICAL CIRCUITS. THE HIGH VOLTAGE ELECTRICAL
CURRENT IN THE CAPACITOR OF THE STROBE LIGHT IS DANGEROUS.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific safety barriers
No specific warning notice
No specific access platform 4.35 m (14 ft. 3 in.)



EFF :

ALL  33-48-14

Page 401
Feb 01/96
 
IAC 
B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

57-37-12-000-001 Removal of the Navigation Light Glazing Panel


33-48-14-991-001 Fig. 401

3. __________
Job Set-up

(Ref. Fig. 401/TASK 33-48-14-991-001)

Subtask 33-48-14-941-050

A. Safety Precautions

(1) Put the safety barriers in position.

(2) Put a warning notice in the cockpit on panel 25VU to tell persons not
to operate the navigation lights or the strobe lights.

Subtask 33-48-14-865-050

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/WING/STROBE 10LV V05

Subtask 33-48-14-010-050

C. Get Access

(1) Put the access platform in position below the applicable zone 534 or
634.

(2) Remove the applicable glazing panel (3) (Ref. TASK 57-37-12-000-001).



EFF :

ALL  33-48-14

Page 402
Aug 01/06
 
IAC 
Strobe Light
Figure 401/TASK 33-48-14-991-001



EFF :

ALL  33-48-14

Page 403
Feb 01/96
 
IAC 
4. Procedure
_________

(Ref. Fig. 401/TASK 33-48-14-991-001)

Subtask 33-48-14-020-050

A. Removal of the Strobe Light

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2


_______
MINUTES AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

(1) Remove the bolts (4) and the washers (5).

(2) Remove the strobe light sufficiently to get access to the electrical
connector (1).

(3) Disconnect the electrical connector (1).

(4) Remove the strobe light (2).

(5) Put blanking caps on the disconnected electrical connectors.



EFF :

ALL  33-48-14

Page 404
Feb 01/96
 
IAC 
TASK 33-48-14-400-001

Installation of the Strobe Light

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific safety barriers
No specific soap solution
No specific warning notice
No specific access platform 4.35 m (14 ft. 3 in.)

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 11-004 USA MIL-T-81533


1.1.1TRICHLOROETHANE (METHYL CHLOROFORM)
(Ref. 20-31-00)
R Material No. 15-008 AIB TN 10138 TYPE II GRADE 2
R CORROSION PREVENTIVE TEMPORARY PROTECTIVE COMPOUND
R (Ref. 20-31-00)
Material No. 19-003 USA AMS 3819
LINT-FREE COTTON CLOTH (Ref. 20-31-00)



EFF :

ALL  33-48-14

Page 405
May 01/06
 
IAC 
C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R 20-28-00-912-004 Electrical Bonding of Components With Conductive


R Bolts and Screws and Bonding Straps in the Fuselage
R and in the Wings (this does not include the tanks)-
33-48-00-710-001 Operational Test of the Anti-Collision/Strobe
Lighting
33-48-00-710-002 Operational Test of the Anti-Collision/Strobe
Lighting
57-37-12-400-001 Installation of the Navigation Light Glazing Panel
33-48-14-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-48-14-941-053

A. Safety Precautions

(1) Make sure that the safety barriers are in position.

(2) Make sure that the warning notice is in position on panel 25VU to
tell persons not to operate the navigation lights or the strobe
lights.

Subtask 33-48-14-860-052

B. Aircraft Maintenance Configuration

(1) Make sure that the access platform is in position below the
applicable zone 534, 634.



EFF :

ALL  33-48-14

Page 406
May 01/06
 
IAC 
Subtask 33-48-14-865-051

C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/WING/STROBE 10LV V05

4. Procedure
_________

(Ref. Fig. 401/TASK 33-48-14-991-001)

Subtask 33-48-14-420-052

A. Preparation for Installation

WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL


_______
MATERIALS ONLY WITH A GOOD SUPPLY OF AIR.
OBEY THE MANUFACTURERS INSTRUCTIONS.
PUT ON PROTECTIVE CLOTHING.
DO NOT GET THEM IN YOUR MOUTH.
DO NOT SMOKE.
DO NOT BREATHE THE GAS.
THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT.
GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.

(1) Clean the component interface and/or the adjacent area with a
MISCELLANEOUS (Material No. 19-003) made moist with CLEANING AGENTS
(Material No. 11-004).

(2) Clean the glazing panel with a MISCELLANEOUS (Material No. 19-003)
made moist with soap solution.

(3) Do an inspection of the component interface and/or the adjacent area.

(4) Make sure that the parts retained from the removed component are
clean and in the correct condition.



EFF :

ALL  33-48-14

Page 407
Feb 01/07
R  
IAC 
**ON A/C 001-012, 014-099,

Subtask 33-48-14-420-050

B. Installation of the Strobe Light

(1) Remove the blanking caps from the disconnected electrical connectors.

(2) Connect the electrical connector (1) to the strobe light (2).

(3) Install the strobe light (2) with the bolts (4) and the washers (5).

(4) Electrically bond the aft bottom bolt (4) (Ref. TASK 20-28-00-912-
004).

R **ON A/C 101-199, 901-999,

Subtask 33-48-14-420-050-A

B. Installation of the Strobe Light

(1) Remove the blanking caps from the disconnected electrical connectors.

(2) Connect the electrical connector (1) to the strobe light (2).

(3) Clean the electrical connector (1) with a MISCELLANEOUS (Material No.
19-003) made moist with CLEANING AGENTS (Material No. 11-004).

(4) Apply a continuous layer of STORAGE PRESERVATION (Material No. 15-


008) to the electrical connector (1).

(5) Install the strobe light (2) with the bolts (4) and the washers (5).

(6) Electrically bond the aft bottom bolt (4) (Ref. TASK 20-28-00-912-
004).

**ON A/C ALL

Subtask 33-48-14-865-052

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
10LV.



EFF :

ALL  33-48-14

Page 408
Feb 01/07
 
IAC 
Subtask 33-48-14-710-050

D. Test

WARNING : DO NOT LOOK DIRECTLY AT THE LIGHT FLASH DURING THE TEST.
_______
SUPPLY A COVER, OR SHIELD, TO GIVE PROTECTION FROM THE LIGHT
FLASH TO PERSONS IN THE TEST AREA.

WARNING : BE CAREFUL IF YOU TOUCH THE STROBE LIGHT WITH THE COVER REMOVED
_______
AND THE POWER APPLIED. SOME COMPONENTS HAVE DANGEROUS VOLTAGES.

CAUTION : DO NOT DISCONNECT THE CONNECTOR DURING OPERATION. ARCING CAN


_______
DAMAGE THE CONTACT PINS.

(1) Do the applicable operational test on the strobe light (Ref. TASK 33-
48-00-710-001) (Ref. TASK 33-48-00-710-002).

Subtask 33-48-14-865-053

E. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/WING/STROBE 10LV V05

5. Close-up
________

Subtask 33-48-14-410-050

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the applicable glazing panel (3) (Ref. TASK 57-37-12-400-
001).

Subtask 33-48-14-865-054

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
10LV.



EFF :

ALL  33-48-14

Page 409
Aug 01/06
 
IAC 
Subtask 33-48-14-942-052

C. Removal of Equipment

(1) Remove the safety barriers.

(2) Remove the warning notice(s).

(3) Remove the access platform(s).

(4) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.



EFF :

ALL  33-48-14

Page 410
Aug 01/06
R  
IAC 
TASK 33-48-14-000-002

Removal of the Strobe Light Flash-Tube Assembly

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

WARNING : DO NOT TOUCH THE STROBE LIGHTS FOR AT LEAST 5 MINUTES AFTER
_______
OPERATION. THE STROBE LIGHT WILL STILL BE HOT.

WARNING : DO NOT REMOVE THE STROBE LIGHT FOR AT LEAST TEN MINUTES AFTER YOU
_______
DE-ENERGIZE THE ELECTRICAL CIRCUITS. THE HIGH VOLTAGE ELECTRICAL
CURRENT IN THE CAPACITOR OF THE STROBE LIGHT IS DANGEROUS.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific safety barriers
No specific warning notice
No specific access platform 4.35 m (14 ft. 3 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

57-37-12-000-001 Removal of the Navigation Light Glazing Panel


33-48-14-991-002 Fig. 402



EFF :

ALL  33-48-14

Page 411
May 01/06
R  
IAC 
3. __________
Job Set-up

Subtask 33-48-14-941-052

A. Safety Precautions

(1) Put a warning notice on panel 25VU to tell persons not to operate the
strobe lights or the navigation lights.

(2) Put the safety barriers in position.

Subtask 33-48-14-865-055

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/WING/STROBE 10LV V05

Subtask 33-48-14-010-051

C. Get Access

(1) Put the access platform in position under the applicable wing-tip
strobe light in zone 534 or 634.

(2) Remove the glazing panel (1) from the applicable wing-tip strobe
light (Ref. TASK 57-37-12-000-001).

4. Procedure
_________

(Ref. Fig. 402/TASK 33-48-14-991-002)

Subtask 33-48-14-020-053

A. Removal of the Strobe Light Flash-Tube Assembly

CAUTION : BE CAREFULL WHEN YOU REMOVE THE ATTACHMENT SCREWS. THE LENS CAN
_______
FALL OUT.

(1) Remove the screws (2), the lens (3) and the gasket (4).



EFF :

ALL  33-48-14

Page 412
Aug 01/06
 
IAC 
Strobe Light Flash Tube Assembly
Figure 402/TASK 33-48-14-991-002



EFF :

ALL  33-48-14

Page 413
Aug 01/06
R  
IAC 
(2) Remove the screws (5) and carefully remove the flash tube assembly
(6).



EFF :

ALL  33-48-14

Page 414
Aug 01/06
R  
IAC 
TASK 33-48-14-400-002

Installation of the Strobe Light Flash-Tube Assembly

WARNING : MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING
_______
NOTICES ARE IN POSITION.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific safety barriers
No specific soap solution
No specific warning notice
No specific access platform 4.35 m (14 ft. 3 in.)

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 19-003 USA AMS 3819


LINT-FREE COTTON CLOTH (Ref. 20-31-00)

C. Expendable Parts

-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------

4 gasket 33-48-14 01 -035



EFF :

ALL  33-48-14

Page 415
May 01/06
R  
IAC 
D. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-48-00-710-001 Operational Test of the Anti-Collision/Strobe


Lighting
33-48-00-710-002 Operational Test of the Anti-Collision/Strobe
Lighting
57-37-12-400-001 Installation of the Navigation Light Glazing Panel
33-48-14-991-002 Fig. 402

3. __________
Job Set-up

Subtask 33-48-14-941-054

A. Safety Precautions

(1) Make sure that the safety barriers are in position.

(2) Make sure that the warning notice is on panel 25VU to tell persons
not to operate the strobe lights or the navigation lights.

Subtask 33-48-14-860-053

B. Aircraft Maintenance Configuration

(1) Make sure that the access platform is in position below the
applicable wing-tip strobe light in zone 534 or 634.

Subtask 33-48-14-865-056

C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/WING/STROBE 10LV V05



EFF :

ALL  33-48-14

Page 416
Aug 01/06
 
IAC 
R

4. Procedure
_________

(Ref. Fig. 402/TASK 33-48-14-991-002)

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE
LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A
LINT-FREE CLOTH.

Subtask 33-48-14-420-053

A. Preparation for Installation

(1) Make sure that the parts retained from the removed component are
clean and in the correct condition.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Clean the glazing panel with a MISCELLANEOUS (Material No. 19-003)
made moist with a warm soap solution.

Subtask 33-48-14-420-051

B. Installation of the Strobe Light Flash-Tube Assembly

(1) Install the flash tube assembly (6) and the screws (5).

(2) Install a new gasket (4), the lens (3) and the screws (2).

Subtask 33-48-14-865-057

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/WING/STROBE 10LV V05



EFF :

ALL  33-48-14

Page 417
Aug 01/06
 
IAC 
R

Subtask 33-48-14-710-051

D. Test

WARNING : DO NOT LOOK DIRECTLY AT THE LIGHT FLASH DURING THE TEST.
_______
SUPPLY A COVER, OR SHIELD, TO GIVE PROTECTION FROM THE LIGHT
FLASH TO PERSONS IN THE TEST AREA.

WARNING : BE CAREFUL IF YOU TOUCH THE STROBE LIGHT WITH THE COVER REMOVED
_______
AND THE POWER APPLIED. SOME COMPONENTS HAVE DANGEROUS VOLTAGES.

CAUTION : DO NOT DISCONNECT THE CONNECTOR DURING OPERATION. ARCING CAN


_______
DAMAGE THE CONTACT PINS.

(1) Do the applicable operational test of the strobe lights (Ref. TASK
33-48-00-710-001) (Ref. TASK 33-48-00-710-002).

Subtask 33-48-14-865-058

E. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/WING/STROBE 10LV V05

5. Close-up
________

Subtask 33-48-14-410-051

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the glazing panel (1) on the applicable wing-tip strobe light
(Ref. TASK 57-37-12-400-001).



EFF :

ALL  33-48-14

Page 418
Aug 01/06
 
IAC 
Subtask 33-48-14-865-059

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
10LV.

Subtask 33-48-14-942-055

C. Removal of Equipment

(1) Remove the safety barriers.

(2) Remove the warning notice(s).

(3) Remove the access platform(s).

(4) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.



EFF :

ALL  33-48-14

Page 419
May 01/06
 
IAC 
POWER SUPPLY UNIT - UPPER BEACON LIGHT (3LV) - REMOVAL/INSTALLATION
___________________________________________________________________

TASK 33-48-36-000-001

Removal of the Power Supply Unit 3LV

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific stepladder 1.5 m (4 ft. 11 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

25-23-41-000-001 Removal of the Ceiling Panels


33-48-36-991-001 Fig. 401

3. __________
Job Set-up

WARNING : ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE
_______
ENVIRONMENT.

Subtask 33-48-36-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/EXT LT/BEACON/UPPER 1LV U06



EFF :

ALL  33-48-36

Page 401
Aug 01/06
 
IAC 
R

Subtask 33-48-36-860-050

B. Aircraft Maintenance Configuration

(1) Make sure that the switch 2LV BEACON ON-OFF on the overhead panel
25VU is in the OFF position.

(2) Make sure that the switch 4WL EMER EXIT LT OFF-ARM-ON on the overhead
panel 25VU is in the OFF position.

(3) Make sure that the pushbutton EMERG LIGHT on the FWD Attendant Panel
(FAP) is in the released position.

Subtask 33-48-36-010-050

C. Get Access

(1) Put the stepladder in position at the applicable location.

(2) Remove the center ceiling panel 241CC to get access to the power
supply unit (1) (Ref. TASK 25-23-41-000-001).

4. Procedure
_________

(Ref. Fig. 401/TASK 33-48-36-991-001)

Subtask 33-48-36-020-050

A. Removal of the Power Supply Unit

(1) Remove and discard the lockwire from the electrical connector (5).

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2


_______
MINUTES AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

(2) Disconnect the electrical connectors (2) and (5) from the power
supply unit (1).

(3) Put blanking caps on the disconnected electrical connectors.

(4) Remove the screws (4) and the washers (3).

(5) Remove the power supply unit (1) from the fuselage.



EFF :

ALL  33-48-36

Page 402
Aug 01/06
 
IAC 
Power Supply Unit 3LV
Figure 401/TASK 33-48-36-991-001



EFF :

ALL  33-48-36

Page 403
Aug 01/06
R  
IAC 
TASK 33-48-36-400-001

Installation of the Power Supply Unit 3LV

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific stepladder 1.5 m (4 ft. 11 in.)

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

No specific lockwire - corrosion resistant steel 0.6mm (0.24


in.) dia.
Material No. 16-003 F ASNB70720
COATING (OBSOLETE USE 16-021) (Ref. 20-31-00)

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

20-28-00-912-004 Electrical Bonding of Components With Conductive


Bolts and Screws and Bonding Straps in the Fuselage
and in the Wings (this does not include the tanks)-
25-23-41-400-001 Installation of the Ceiling Panels
33-48-00-710-001 Operational Test of the Anti-Collision/Strobe
Lighting
33-48-36-991-001 Fig. 401



EFF :

ALL  33-48-36

Page 404
Aug 01/06
R  
IAC 
3. __________
Job Set-up

Subtask 33-48-36-860-051

A. Aircraft Maintenance Configuration

(1) Make sure that the switch 2LV BEACON ON-OFF on the overhead panel
25VU is in the OFF position.

(2) Make sure that the switch 4WL EMER EXIT LT OFF-ARM-ON on the overhead
panel 25VUis in the OFF position.

(3) Make sure that the pushbutton EMERG LIGHT on the FWD Attendant Panel
(FAP) is in the released position.

(4) Make sure that the stepladder is in position at the applicable


position.

(5) Make sure that the center ceiling panel 241CC is removed.

Subtask 33-48-36-865-051

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/EXT LT/BEACON/UPPER 1LV U06

4. Procedure
_________

(Ref. Fig. 401/TASK 33-48-36-991-001)

Subtask 33-48-36-420-050

A. Installation of the Power Supply Unit

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Put the power supply unit (1) in position on the fuselage.



EFF :

ALL  33-48-36

Page 405
Aug 01/06
 
IAC 
(4) Install the power supply unit (1) with the screws (4) and the washers
(3) and tighten.

(5) Apply STRUCTURE PAINTS (Material No. 16-003) on one of the screws (4)
(Ref. TASK 20-28-00-912-004).

(6) Remove the blanking caps from the electrical connectors.

(7) Make sure that the electrical connectors are clean and in the correct
condition.

(8) Connect the electrical connectors (2) and (5) to the power supply
unit (1).

(9) Safety the electrical connector (5) with lockwire - corrosion


resistant steel 0.6mm (0.24 in.) dia..

Subtask 33-48-36-710-050

B. Do an operational test of the upper beacon/strobe light 7LV (Ref. TASK


33-48-00-710-001).

5. Close-up
________

Subtask 33-48-36-410-050

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the center ceiling panel 241CC (Ref. TASK 25-23-41-400-001).

(3) Remove the stepladder.



EFF :

ALL  33-48-36

Page 406
Aug 01/06
R  
IAC 
POWER SUPPLY UNIT - LOWER BEACON LIGHT (4LV) - REMOVAL/INSTALLATION
___________________________________________________________________

TASK 33-48-37-000-001

Removal of the Power Supply Unit 4LV

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

53-35-13-000-002 Removal of the Quick-Release Access Panels from the


Belly Fairing Structure
33-48-37-991-001 Fig. 401

3. __________
Job Set-up

WARNING : ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE
_______
ENVIRONMENT.

Subtask 33-48-37-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/EXT LT/BEACON/LOWER 5LV U03



EFF :

ALL  33-48-37

Page 401
Aug 01/06
 
IAC 
R

Subtask 33-48-37-860-050

B. Aircraft Maintenance Configuration

(1) Make sure that the switch 2LV BEACON ON-OFF on the overhead panel
25VU is in the OFF position.

Subtask 33-48-37-010-050

C. Get Access

(1) Remove the access panel 191HB at the belly fairing to get access to
the power supply unit (1) (Ref. TASK 53-35-13-000-002).

4. Procedure
_________

(Ref. Fig. 401/TASK 33-48-37-991-001)

Subtask 33-48-37-020-050

A. Removal of the Power Supply Unit

(1) Remove and discard the lockwire from the electrical connector (5).

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2


_______
MINUTES AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

(2) Disconnect the electrical connectors (2) and (5) from the power
supply unit (1).

(3) Put blanking caps on the disconnected electrical connectors.

(4) Remove the screws (4) and the washers (3).

(5) Remove the power supply unit (1) from the fuselage.



EFF :

ALL  33-48-37

Page 402
Aug 01/06
 
IAC 
Power Supply Unit 4LV
Figure 401/TASK 33-48-37-991-001



EFF :

ALL  33-48-37

Page 403
Feb 01/96
 
IAC 
TASK 33-48-37-400-001

Installation of the Power Supply Unit 4LV

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

No specific lockwire - corrosion resistant steel 0.6mm (0.24


in.) dia.
Material No. 16-003 F ASNB70720
COATING (OBSOLETE USE 16-021) (Ref. 20-31-00)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

20-28-00-912-004 Electrical Bonding of Components With Conductive


Bolts and Screws and Bonding Straps in the Fuselage
and in the Wings (this does not include the tanks)-
33-48-12-700-001 Test of the Lower Beacon/Strobe Light 6LV
53-35-13-400-002 Installation of the Quick-Release Access Panels on
the Belly Fairing Structure
33-48-37-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-48-37-860-051

A. Aircraft Maintenance Configuration

(1) Make sure that the switch 2LV BEACON ON-OFF on the overhead panel is
in the OFF position.

(2) Make sure that the access panel 191HB at the belly fairing is
removed.



EFF :

ALL  33-48-37

Page 404
Aug 01/06
R  
IAC 
Subtask 33-48-37-865-051

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/EXT LT/BEACON/LOWER 5LV U03

4. Procedure
_________

(Ref. Fig. 401/TASK 33-48-37-991-001)

Subtask 33-48-37-420-050

A. Installation of the Power Supply Unit

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Put the power supply unit (1) in position on the fuselage.

(4) Install the power supply unit (1) with the screws (4) and the washers
(3) and tighten.

(5) Apply STRUCTURE PAINTS (Material No. 16-003) on one of the screws (4)
(Ref. TASK 20-28-00-912-004).

(6) Remove the blanking caps from the electrical connectors.

(7) Make sure that the electrical connectors are clean and in the correct
condition.

(8) Connect the electrical connectors (2) and (5) to the power supply
unit (1).

(9) Safety the electrical connector (5) with lockwire - corrosion


resistant steel 0.6mm (0.24 in.) dia..



EFF :

ALL  33-48-37

Page 405
Aug 01/06
 
IAC 
INTENTIONALLY BLANK


R



 33-48-37

Page 406
Aug 01/06
 
IAC 
Subtask 33-48-37-710-050

B. Do an operational test of the lower beacon/strobe light 6LV (Ref. TASK


33-48-12-700-001).

5. Close-up
________

Subtask 33-48-37-410-050

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the access panel 191HB to the belly fairing (Ref. TASK 53-35-
13-400-002).



EFF :

ALL  33-48-37

Page 407
May 01/06
 
IAC 
POWER SUPPLY UNIT - WING TIP STROBE LIGHT (14LV,15LV) - REMOVAL/INSTALLATION
____________________________________________________________________________

TASK 33-48-38-000-001

Removal of the Power Supply Unit

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific safety barriers
No specific warning notice
No specific access platform 4.0 m (13 ft. 1 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-48-38-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-48-38-941-052

A. Safety Precautions

(1) Put the safety barriers in position.

(2) Put a warning notice in position on panel 25VU to tell persons not to
operate the strobe lights or the navigation lights.



EFF :

ALL  33-48-38

Page 401
May 01/06
R  
IAC 
Subtask 33-48-38-865-050

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/WING/STROBE 10LV V05

Subtask 33-48-38-010-050

C. Get Access

(1) Put the access platform in position below the applicable access panel
534AB(634AB).

(2) Remove the applicable access panel:


FOR 15LV
remove 534AB
FOR 14LV
remove 634AB

4. Procedure
_________

(Ref. Fig. 401/TASK 33-48-38-991-001)

Subtask 33-48-38-020-050

A. Removal of the Power Supply Unit

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2


_______
MINUTES AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

(1) Disconnect the electrical connectors (1) from the power supply unit
(4).



EFF :

ALL  33-48-38

Page 402
Aug 01/06
 
IAC 
Power Supply Unit
Figure 401/TASK 33-48-38-991-001



EFF :

ALL  33-48-38

Page 403
Feb 01/96
 
IAC 
(2) Put blanking caps on the disconnected electrical connectors.

(3) Remove the bolts (3) and the washers (2).

NOTE : The power supply unit has two location pins. They locate in
____
the location pin sockets of the wing tip.

(4) Carefully remove the power supply unit (4).



EFF :

ALL  33-48-38

Page 404
Feb 01/96
 
IAC 
TASK 33-48-38-400-001

Installation of the Power Supply Unit

WARNING : MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING
_______
NOTICES ARE IN POSITION.

WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific safety barriers
No specific warning notice
No specific access platform 4 m (13 ft. 1 in.)

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 11-004 USA MIL-T-81533


1.1.1TRICHLOROETHANE (METHYL CHLOROFORM)
(Ref. 20-31-00)
Material No. 19-003 USA AMS 3819
LINT-FREE COTTON CLOTH (Ref. 20-31-00)



EFF :

ALL  33-48-38

Page 405
Feb 01/96
 
IAC 
C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

20-28-00-912-004 Electrical Bonding of Components With Conductive


Bolts and Screws and Bonding Straps in the Fuselage
and in the Wings (this does not include the tanks)-
33-48-00-710-002 Operational Test of the Anti-Collision/Strobe
Lighting
33-48-38-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-48-38-941-053

A. Safety Precautions

(1) Make sure that the safety barriers are in position.

(2) Make sure that the warning notice in on panel 25VU to tell persons
not to operate the strobe lights or the navigation lights.

Subtask 33-48-38-865-051

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/WING/STROBE 10LV V05

Subtask 33-48-38-860-050

C. Aircraft Maintenance Configuration

(1) Make sure that the access platform is position below the applicable
power suppply unit.

(2) Make sure that the access panels 534AB (634AB) are removed.



EFF :

ALL  33-48-38

Page 406
Aug 01/06
 
IAC 
4. Procedure
_________

(Ref. Fig. 401/TASK 33-48-38-991-001)

Subtask 33-48-38-420-051

A. Preparation for Installation

WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL


_______
MATERIALS ONLY WITH A GOOD SUPPLY OF AIR.
OBEY THE MANUFACTURERS INSTRUCTIONS.
PUT ON PROTECTIVE CLOTHING.
DO NOT GET THEM IN YOUR MOUTH.
DO NOT SMOKE.
DO NOT BREATHE THE GAS.
THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT.
GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.

(1) Clean the component interface and/or the adjacent area with a clean
MISCELLANEOUS (Material No. 19-003) made moist with CLEANING AGENTS
(Material No. 11-004).

(2) Make sure that the parts retained from the removed component are
clean and in the correct condition.

(3) Do an inspection of the component interface and/or the adjacent area.

Subtask 33-48-38-420-050

B. Installation of the Power Supply Unit

(1) Carefully install the power supply unit (4), and make sure that the
location pins are correctly engaged in their sockets.

(2) Attach the power supply unit (4) with the bolts (3) and the washers
(2).

(3) Electrically bond the applicable bolt (3) (Ref. TASK 20-28-00-912-
004):
- for the left wing bond the inboard bolt (3)
- for the right wing bond the outboard bolt (3).

(4) Remove the blanking caps from the disconnected electrical connectors.

(5) Connect the electrical connectors (1) to the power supply unit.



EFF :

ALL  33-48-38

Page 407
Aug 01/06
R  
IAC 
Subtask 33-48-38-865-052

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
10LV.

Subtask 33-48-38-710-050

D. Test

WARNING : DO NOT LOOK DIRECTLY AT THE LIGHT FLASH DURING THE TEST.
_______
SUPPLY A COVER, OR SHIELD, TO GIVE PROTECTION FROM THE LIGHT
FLASH TO PERSONS IN THE TEST AREA.

(1) Do an operational test of the strobe light (Ref. TASK 33-48-00-710-


002)

Subtask 33-48-38-865-053

E. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/WING/STROBE 10LV V05

5. Close-up
________

Subtask 33-48-38-410-050

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the applicable access panel:


- FOR 15LV
install 534AB
- FOR 14LV
install 634AB.



EFF :

ALL  33-48-38

Page 408
Aug 01/06
 
IAC 
Subtask 33-48-38-865-054

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
10LV.

Subtask 33-48-38-942-052

C. Removal of Equipment

(1) Remove the safety barriers.

(2) Remove the warning notice(s).

(3) Remove the access platform(s).

(4) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.



EFF :

ALL  33-48-38

Page 409
Aug 01/06
R  
IAC 
POWER SUPPLY UNIT - TAIL CONE STROBE LIGHT (18LV) - REMOVAL/INSTALLATION
________________________________________________________________________

TASK 33-48-39-000-001

Removal of the Power Supply Unit (18LV) of the Tail Cone Strobe-Light

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific access platform 3.5 m (11 ft. 6 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
33-48-39-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-48-39-861-050

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-48-39-865-053

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/WING/STROBE 10LV V05



EFF :

ALL  33-48-39

Page 401
Aug 01/06
 
IAC 
R

Subtask 33-48-39-010-050

C. Get Access

(1) Put the access platform in position below the access door 314AR at
Zone 310.

(2) Open the access door 314AR.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-48-39-991-001)

Subtask 33-48-39-020-050

A. Removal of the Power Supply Unit (18LV)

(1) Remove and discard the lockwires from the electrical connectors (4)
and (5).

(2) Disconnect the electrical connectors (4) and (5).

(3) Put blanking caps on the disconnected electrical connectors.

(4) Remove the screws (2) and the washers (3).

(5) Remove the power supply unit (1).



EFF :

ALL  33-48-39

Page 402
Aug 01/06
 
IAC 
Power Supply Unit
Figure 401/TASK 33-48-39-991-001



EFF :

ALL  33-48-39

Page 403
Feb 01/96
 
IAC 
TASK 33-48-39-400-001

Installation of the Power Supply Unit (18LV) of the Tail Cone Strobe-Light

WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL MATERIALS


_______
ONLY WITH A GOOD SUPPLY OF AIR.
OBEY THE MANUFACTURERS INSTRUCTIONS.
PUT ON PROTECTIVE CLOTHING.
DO NOT GET THEM IN YOUR MOUTH.
DO NOT SMOKE.
DO NOT BREATHE THE GAS.
THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT.
GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific lint-free cloth


No specific nonmetallic scraper
No specific access platform 3.5 m (11 ft. 6 in.)

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R Material No. 09-013 C Z-16.127


CORROSION INHIBITING BRUSH CONSISTENCY
(Ref. 20-31-00)
Material No. 11-003 USA ASTM D 740
METHYL-ETHYL-KETONE (Ref. 20-31-00)
Material No. 19-010 USA AMS 5687
LOCKWIRE STAINLESS STEEL ANNEALED 0.8MM DIA
(Ref. 20-31-00)



EFF :

ALL  33-48-39

Page 404
May 01/06
 
IAC 
C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

20-28-00-720-007 Test of the Bonding of the Electrical and Electrical


Equipment (that is not Related to the Fluid Systems)
20-28-00-912-004 Electrical Bonding of Components With Conductive
Bolts and Screws and Bonding Straps in the Fuselage
and in the Wings (this does not include the tanks)-
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
33-48-00-710-002 Operational Test of the Anti-Collision/Strobe
Lighting
33-48-39-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-48-39-860-050

A. Aircraft Maintenance Configuration

(1) Make sure that the access platform is in position below the access
door 314AR.

(2) Make sure that the access door 314AR is open.

(3) Make sure that the aircraft electrical circuits are energized
(Ref. TASK 24-41-00-861-002).

Subtask 33-48-39-865-051

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/WING/STROBE 10LV V05



EFF :

ALL  33-48-39

Page 405
Aug 01/06
 
IAC 
R

4. Procedure
_________

(Ref. Fig. 401/TASK 33-48-39-991-001)

WARNING : OBEY THE MANUFACTURERS INSTRUCTIONS WHEN YOU USE THE SPECIAL
_______
MATERIAL.
THIS MATERIAL IS DANGEROUS.

Subtask 33-48-39-910-050

A. Preparation for Installation

(1) Do an inspection of the component interface and/or the adjacent area.

(2) Make sure that the parts retained from the removed component are
clean and in the correct condition.

(3) Clean the component interface and/or the adjacent area.

(4) Remove the used sealant from the ground bonding surface of the
support and the power supply unit with a nonmetallic scraper.

(5) Make sure that the ground bonding surfaces have no signs of paint,
sealant or corrosion.

(6) Clean the ground bonding surfaces with CLEANING AGENTS (Material No.
11-003) and a lint-free cloth.

Subtask 33-48-39-420-050

B. Installation of the Power Supply Unit (18LV)

(1) Make sure that the ground bonding attachment point point is clean
(Ref. TASK 20-28-00-912-004).

(2) Install the power supply unit (1) with the washers (3) and the screws
(2).

(3) Tighten the screws (2) diagonally opposite.

(4) Remove the blanking caps from the electrical connectors.

(5) Make sure that the electrical connectors are clean and in the correct
condition.



EFF :

ALL  33-48-39

Page 406
Aug 01/06
 
IAC 
(6) Connect the electrical connectors (4) and (5).

(7) Safety the electrical connectors (4) and (5) with MISCELLANEOUS
(Material No. 19-010)

(8) Apply SEALANTS (Material No. 09-013) to the ground bonding attachment
point.

(9) Make sure that the bonding contact resistance between the power
supply unit and the support is not higher than 10 milliohms
(Ref. TASK 20-28-00-720-007).

Subtask 33-48-39-865-052

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/WING/STROBE 10LV V05

Subtask 33-48-39-710-050

D. Do the operational test of the anti-collision/strobe lighting (Ref. TASK


33-48-00-710-002).

5. Close-up
________

Subtask 33-48-39-410-050

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Close the access door 314AR.

(3) Remove the access platform(s).

Subtask 33-48-39-862-050

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-48-39

Page 407
Aug 01/06
 
IAC 
WING AND ENGINE SCAN LIGHTING - DESCRIPTION AND OPERATION
_________________________________________________________

1. _______
General
The wing and engine scan lights illuminate the wing leading edge and the
engine nacelle, on each side of the aircraft fuselage. These areas can be
examined during the flight or on the ground.

2. Component
__________________
Location
(Ref. Fig. 001)

-------------------------------------------------------------------------------
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
2LX SW-EXT LT/WING 25VU 210
3LX LT-WING & ENG SCAN, L 231 33-49-11
4LX LT-WING & ENG SCAN, R 232 33-49-11

3. ___________
Description
(Ref. Fig. 002)
The wing and engine scan light system has two lights 3LX and 4LX with a
fixed single filament. The lights are installed one on each side in the
forward fuselage of the aircraft. An attached transformer gives the rated
operation voltage to each light. Electrical power comes from the 115 VAC
busbars 202XP and 103XP through the circuit breakers 1LX and 5LX.

4. _________
Operation
(Ref. Fig. 002)
The switch 2LX is supplied with 115 VAC when:
- the busbars 202XP and 103XP are energized,
- the circuit breakers 1LX and 5LX are closed.
The wing and engine scan lights come on when the switch 2LX is in the ON
position.



EFF :

ALL  33-49-00

Page 1
Feb 01/96
 
IAC 
Wing and Engine Scan Lights - Component Location
Figure 001



EFF :

ALL  33-49-00

Page 2
Feb 01/96
 
IAC 
Wing and Engine Scan Lights - Schematic
Figure 002



EFF :

ALL  33-49-00

Page 3
Feb 01/96
 
IAC 
WING AND ENGINE SCAN LIGHTING - DEACTIVATION/REACTIVATION
_________________________________________________________

TASK 33-49-00-040-001

Deactivation of the Wing and Engine Scan Light (3LX, 4LX)

1. __________________
Reason for the Job

Refer to the CDL TASK: 33-1


Wing/engine scan light cover 3(4) LX

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

R No specific blanking cap


No specific circuit breaker(s) safety clip(s)
No specific soap solution
No specific 1 WARNING NOTICE

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 05-065 C Z-24.380


EROSION PROTECTIVE TAPE (Ref. 20-31-00)
Material No. 08-052 USA AMS-T-23397 AND/OR L-T-80B
SELF ADHESIVEALUMINIUM TAPE (Ref. 20-31-00)
Material No. 19-003 USA AMS 3819
LINT-FREE COTTON CLOTH (Ref. 20-31-00)

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-49-11-000-001 Removal of the Wing and Engine Scan Light (3LX, 4LX)
R



EFF :

ALL  33-49-00

Page 401
Feb 01/08
 
IAC 
3. __________
Job Set-up

Subtask 33-49-00-941-050

A. Safety Precautions

(1) On the EXT LT section of the overhead panel 25VU:


- Put a WARNING NOTICE in position to tell persons not to operate the
wing and engine scan light.

Subtask 33-49-00-865-051

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU LIGHTING/EXT LT/WING/AND ENG SCAN/R 1LX W03
122VU LIGHTING/EXT LT/WING/AND ENG SCAN/L 5LX W02

4. Procedure
_________

Subtask 33-49-00-040-050

A. Deactivation of the Wing and Engine Scan Light


R

R (1) If you do not replace the cracked wing and engine scan light, you can
R do an alternative repair with transparent high-speed tape as follows:

(a) Clean the surface of the wing and engine scan-light lens with
MISCELLANEOUS (Material No. 19-003) made moist with warm soap
solution.

(b) Dry the surface of the wing and engine scan-light lens with a
clean MISCELLANEOUS (Material No. 19-003).

(c) Apply SPECIAL MATERIALS (Material No. 05-065) or BONDING AND


ADHESIVE COMPOUNDS (Material No. 08-052) to cover the crack(s).

NOTE : Make sure that the tape is correctly installed and has no
____
bubbles, wrinkles or tears in it.

(d) Let the tape cure for 15 minutes minimum at a minimum temperature
of 15 deg.C (59.00 deg.F).
R



EFF :

ALL  33-49-00

Page 402
Feb 01/08
 
IAC 
R (e) Write in the aircraft technical log that the wing and engine scan
R light is damaged.

R (2) If you do not replace the cracked wing and engine scan light, you can
R do an alternative repair with non-transparent high-speed tape. Then
R do the deactivation of the wing and engine scan light as follows:
R - In the forward passenger compartment:

R (a) Disconnect the movable connector from the applicable light and
R put a blanking cap on the disconnected connector (Ref. TASK 33-
49-11-000-001).

R (b) Write in the aircraft technical log that the wing and engine scan
R light is deactivated.

5. Close-up
________

Subtask 33-49-00-865-052

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LX, 5LX.

Subtask 33-49-00-942-051

B. Put the aircraft back to its initial configuration.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the warning notice(s).



EFF :

ALL  33-49-00

Page 403
Feb 01/08
 
IAC 
TASK 33-49-00-440-001

Reactivation of the Wing and Engine Scan Light (3LX, 4LX)

1. __________________
Reason for the Job

Refer to the CDL TASK: 33-1


Wing/engine scan light cover 3(4) LX

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific 1 WARNING NOTICE

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-49-11-000-001 Removal of the Wing and Engine Scan Light (3LX, 4LX)
33-49-11-400-001 Installation of the Wing and Engine Scan Light (3LX,
4LX)

3. __________
Job Set-up

Subtask 33-49-00-941-051

A. Safety Precautions

(1) On the EXT LT section of the overhead panel 25VU:


- Put a WARNING NOTICE in position to tell persons not to operate the
wing and engine scan light.



EFF :

ALL  33-49-00

Page 404
May 01/05
 
IAC 
Subtask 33-49-00-865-053

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/EXT LT/WING/AND ENG SCAN/R 1LX W03
122VU LIGHTING/EXT LT/WING/AND ENG SCAN/L 5LX W02

4. Procedure
_________

Subtask 33-49-00-440-050

A. Reactivation of the Wing and Engine Scan Light

(1) Replace the wing and engine scan light (Ref. TASK 33-49-11-000-001)
and (Ref. TASK 33-49-11-400-001).

5. Close-up
________

Subtask 33-49-00-865-054

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1LX, 5LX

Subtask 33-49-00-942-052

B. Put the aircraft back to its initial configuration.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the warning notice(s).



EFF :

ALL  33-49-00

Page 405
Aug 01/06
 
IAC 
WING AND ENGINE SCAN LIGHTING - ADJUSTMENT/TEST
_______________________________________________

TASK 33-49-00-710-001

Operational Test of the Wing and Engine Scan Lights

1. __________________
Reason for the Job

Make sure that the wing/engine scan lights operate correctly.

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-49-00-861-051

A. Energize the aircraft electrical circuits


(Ref. TASK 24-41-00-861-002).

Subtask 33-49-00-865-050

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R
122VU LIGHTING/EXT LT/WING/AND ENG SCAN/R 1LX W03
122VU LIGHTING/EXT LT/WING/AND ENG SCAN/L 5LX W02



EFF :

ALL  33-49-00

Page 501
Aug 01/06
 
IAC 
R

4. Procedure
_________

Subtask 33-49-00-710-050

A. Operational Test of the Wing and Engine Scan Lights

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the panel 25VU: From each side of the fuselage:


- set the EXT LT/WING selector - the wing/engine scan-lights come on,
switch to ON,

- set the EXT LT/WING selector - the wing/engine scan lights go off.
switch to OFF.

5. Close-up
________

Subtask 33-49-00-862-051

A. De-energize the aircraft electrical circuits


(Ref. TASK 24-41-00-862-002).



EFF :

ALL  33-49-00

Page 502
Aug 01/06
 
IAC 
LIGHT - WING AND ENGINE SCAN (3LX,4LX) - REMOVAL/INSTALLATION
_____________________________________________________________

TASK 33-49-11-000-001

Removal of the Wing and Engine Scan Light (3LX, 4LX)

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2 MINUTES


_______
AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking cap


No specific circuit breaker(s) safety clip(s)
No specific access platform 3.50 m (11 ft. 6 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-49-11-991-001 Fig. 401



EFF :

ALL  33-49-11

Page 401
Feb 01/96
 
IAC 
3. __________
Job Set-up

Subtask 33-49-11-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 4LX
R
122VU LIGHTING/EXT LT/WING/AND ENG SCAN/R 1LX W03
R
FOR 3LX
R
122VU LIGHTING/EXT LT/WING/AND ENG SCAN/L 5LX W02

Subtask 33-49-11-010-051

B. Get Access

(1) Put the access platform in position in zone 230.

(2) Remove the sidewall panel in the forward passenger compartment:


- FOR 3LX
231RW
- FOR 4LX
232KW

(3) Remove the thermal and acoustic insulation in zones 231 and 232.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-49-11-991-001)

Subtask 33-49-11-020-050

A. Removal of the Wing and Engine Scan Light

(1) Outside the aircraft:

(a) Loosen the 16 screws (2) which attach the wing and engine scan
light (1) to the structure (3) of the aircraft.



EFF :

ALL  33-49-11

Page 402
Aug 01/06
 
IAC 
Wing and Engine Scan Light
Figure 401/TASK 33-49-11-991-001



EFF :

ALL  33-49-11

Page 403
Aug 01/06
R  
IAC 
(2) Inside the forward passenger compartment:

(a) Disconnect the movable connector (4) from the light (1) and put a
blanking cap on the disconnected connector.

(3) Remove the wing and engine scan light (1).

NOTE : It could be possible that the wing and engine scan lights are
____
not easy to remove. Do not use tools which could damage the
aircraft structure.



EFF :

ALL  33-49-11

Page 404
Aug 01/06
R  
IAC 
TASK 33-49-11-400-001

Installation of the Wing and Engine Scan Light (3LX, 4LX)

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking cap


No specific lint-free cloth
No specific non-metallic scraper
No specific access platform 3.5 m (11 ft. 6 in.)

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 09-019 USA AMS 3267/3


LOW ADHESION CORROSION INHIBITING SEALANT
(Ref. 20-31-00)
R Material No. 11-003 USA ASTM D 740
METHYL-ETHYL-KETONE (Ref. 20-31-00)

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-49-00-710-001 Operational Test of the Wing and Engine Scan Lights


33-49-11-991-001 Fig. 401



EFF :

ALL  33-49-11

Page 405
Nov 01/04
 
IAC 
3. __________
Job Set-up

Subtask 33-49-11-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 4LX
R
122VU LIGHTING/EXT LT/WING/AND ENG SCAN/R 1LX W03
R
FOR 3LX
R
122VU LIGHTING/EXT LT/WING/AND ENG SCAN/L 5LX W02

Subtask 33-49-11-010-052

B. Get Access

(1) Make sure that the access platform is in position in zone 230.

(2) Make sure that the sidewall panel is removed in the forward passenger
compartment:
- FOR 3LX
231RW.
- FOR 4LX
232KW.

(3) Make sure that the thermal and acoustic insulation is removed in zone
231/232.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-49-11-991-001)

Subtask 33-49-11-914-050

A. Installation of a sealant

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.



EFF :

ALL  33-49-11

Page 406
Aug 01/06
 
IAC 
(3) Remove the used sealant from the aircraft structure with a non-
metallic scraper.

(4) Clean the aircraft structure with CLEANING AGENTS (Material No. 11-
003) and a lint-free cloth.

(5) Install the SEALANTS (Material No. 09-019) between the wing and
engine scan light (1) and the structure (3) of the aircraft.

Subtask 33-49-11-420-050

B. Installation of the Wing and Engine Scan Light

(1) Inside the forward passenger compartment, install the new wing and
engine scan light (1).

(2) Remove the blanking cap and connect the movable connector (4) to the
light (1).

(3) Outside the aircraft, tighten the 16 screws (2) which attach the wing
and engine scan light (1) to the aircraft structure (3).

Subtask 33-49-11-865-061

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 4LX
R
122VU LIGHTING/EXT LT/WING/AND ENG SCAN/R 1LX W03
R
FOR 3LX
R
122VU LIGHTING/EXT LT/WING/AND ENG SCAN/L 5LX W02

Subtask 33-49-11-710-050

D. Operational Test of the Wing and Engine Scan Lights

(1) Do the operational test of the Wing and Engine Scan Lights (Ref. TASK
33-49-00-710-001).



EFF :

ALL  33-49-11

Page 407
Aug 01/06
 
IAC 
5. Close-up
________

Subtask 33-49-11-410-050

A. Close Access

(1) Install the thermal and acoustic insulation in zones 231/232.

(2) Install the sidewall panel in the forward passenger compartment.

(3) Make sure that the work area is clean and clear of tool(s) and other
items.

(4) Remove the access platform(s).



EFF :

ALL  33-49-11

Page 408
Aug 01/06
R  
IAC 
TASK 33-49-11-960-001

R Replacement of the lamp of the Wing and Engine Scan Light

WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2 MINUTES


_______
AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.

WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______

CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.


_______
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE
CLOTH.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific access platform 3.5 m (11 ft. 6 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-49-00-710-001 Operational Test of the Wing and Engine Scan Lights

**ON A/C 001-012, 014-099,

33-49-11-991-003 Fig. 402

**ON A/C 101-199, 901-999,

33-49-11-991-003-A Fig. 402A



EFF :

ALL  33-49-11

Page 409
Aug 01/07
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-49-11-865-059

R A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
FOR 4LX
122VU LIGHTING/EXT LT/WING/AND ENG SCAN/R 1LX W03
FOR 3LX
122VU LIGHTING/EXT LT/WING/AND ENG SCAN/L 5LX W02

Subtask 33-49-11-010-050

B. Get Access

(1) Put the access platform in position at zone 230.

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 402/TASK 33-49-11-991-003)

**ON A/C 101-199, 901-999,

(Ref. Fig. 402A/TASK 33-49-11-991-003-A)

**ON A/C 001-012, 014-099,

Subtask 33-49-11-020-052

A. Removal of the Lamp

(1) Remove the four screw (2) from the lens assembly (1).

(2) Remove the lens assembly (1) away from the housing (7).



EFF :

ALL  33-49-11

Page 410
Aug 01/07
 
IAC 
Lamp of the Wing and Engine Scan Light
Figure 402/TASK 33-49-11-991-003


R

EFF :

001-012, 014-099,  33-49-11

Page 411
Aug 01/06
 
IAC 
Lamp of the Wing and Engine Scan Light
Figure 402A/TASK 33-49-11-991-003-A


R

EFF :

101-199, 901-999,  33-49-11

Page 412
Feb 01/07
 
IAC 
(3) Remove the screw (11), the washers (10) and the nut (9). Release the
terminal (3) from the lens assembly (1).

(4) Remove the two screws (4) from the retainer (5).

(5) Remove the retainer (5).

(6) Pull the lamp (8) away from the housing (7) and disconnect the two
electrical terminals (6).

(7) Remove the lamp (8).

Subtask 33-49-11-420-053

B. Installation of the Lamp

(1) Connect the electrical terminals (6) to the new lamp (8) and install
it in the position in its housing (7). Hold it in this position.

(2) Put the retainer (5) in position.

(3) Attach the assembly. To do this, tighten the screws (4).

(4) Attach the terminal (3) to the lens assembly (1) with the nut (9),
the washers (10) and the screw (11).

(5) Install the lens assembly (1) in the position on the housing (7).

(6) Attach the assembly. To do this, tighten the screws (2).

R **ON A/C 101-199, 901-999,

Subtask 33-49-11-020-052-A

A. Removal of the Lamp

(1) Loosen the four fasteners (3).

(2) Carefully remove the lamp assembly (2).

(3) Hold the lamp assembly (2).

(4) Remove the three screws (7) and washers (6).

(5) Remove the lamp holder (5) from the lamp assembly (2).


R

EFF :

ALL  33-49-11

Page 413
Feb 01/07
 
IAC 
(6) Remove the lamp (4) from the lamp holder (5).

Subtask 33-49-11-420-053-A

B. Installation of the Lamp

(1) Install a new lamp (4) on the lamp holder (5).

(2) Hold the lamp assembly (2).

(3) Carefully, put the lamp holder (5) in position on the lamp assembly
(2).

(4) Install the three washers (6) and screws (7).

(5) Put the lamp assembly (2) in position.

R NOTE : Manually adjust to centre the optical support of the lamp. Use
____
R a shim and check that the peripheral gap between the lamp
R assembly (2) and the lamp houssing assembly (1) is 0.5 mm
R minimum.

(6) Tighten the four fasteners (3).

**ON A/C ALL

Subtask 33-49-11-865-060

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
FOR 4LX
1LX
FOR 3LX
5LX

Subtask 33-49-11-710-053

D. Operational Test of the lighting

(1) Do the operational test of the Wing and Engine Scan Lights (Ref. TASK
33-49-00-710-001).



EFF :

ALL  33-49-11

Page 414
Aug 01/07
 
IAC 
5. Close-up
________

Subtask 33-49-11-942-054

A. Put the aircraft back to its initial configuration.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the access platform(s).



EFF :

ALL  33-49-11

Page 415
Feb 01/07
R  
IAC 
EMERGENCY LIGHTING - DESCRIPTION AND OPERATION
______________________________________________

1. General
_______

R **ON A/C 001-012, 014-099, 901-999,

The emergency lighting system is installed to give:


- illumination of the cabin and the exit areas during emergency conditions,
- illumination of the escape route over the wings,
- illumination of the emergency-escape hatch handles at the emergency exits,
- power supply of the exit location signs and the exit marking signs,
- power supply to the integral lights of the door escape slides,
- illumination of the Floor-Proximity Emergency-Escape Path-Marking System
(FPEEMS).

R **ON A/C 101-199,

R The emergency lighting system is installed to give:


R - illumination of the cabin and the exit areas during emergency conditions,
R - power supply of the exit location signs and the exit marking signs,
R - power supply to the integral lights of the door escape slides,
R - illumination of the Floor-Proximity Emergency-Escape Path-Marking System
R (FPEEMS).

R **ON A/C ALL

2. __________________
Component Location

**ON A/C 001-012, 014-099,

A. Emergency Power Supply Units (EPSU)


The EPSUs control and monitor the emergency lighting system. They are
installed in the ceiling of the passenger compartment.

B. Cabin Emergency Lights


The ceiling emergency lights are installed to give sufficient
illumination in an emergency condition. The lights are installed in the
ceiling panels of the aisles, cross-aisles and exit areas.
The exit marking signs are installed to show the position of the exits.
The lights are installed near each passenger/crew door and emergency
exit.
The exit location signs are installed to show the position of the exit
areas. The lights are installed in the aisles.



EFF :

ALL  33-50-00

Page 1
Feb 01/07
 
IAC 
C. FPEEPMS
The FPEEPMS is installed on the floor or on the seats (as applicable) at
the aisle and the emergency-exit area. The system provides floor-level
illumination of the passenger aisles and escape routes in the event that
smoke obscures normal emergency lighting.

D. Integrated Escape Slide Lights


The escape slide lights are integrated in the escape slides. They come on
when the escape slides are deployed.

R **ON A/C 101-199, 901-999,

A. Emergency Power Supply Units (EPSU)


The EPSUs control and monitor the emergency lighting system. They are
installed in the ceiling of the passenger compartment.

B. Cabin Emergency Lights


The ceiling emergency lights are installed to give sufficient
illumination in an emergency condition. The lights are installed in the
ceiling panels of the aisles, cross-aisles and exit areas.
The exit marking signs are installed to show the position of the exits.
The lights are installed near each passenger/crew door and emergency
exit.
The exit location signs are installed to show the position of the exit
areas. The lights are installed in the aisles.

C. Photoluminescent Marking System


The system consists of a number of flexible photoluminescent strips. They
are installed on the floor and on convertible seats (if applicable) on
the two sides of the aisle and the emergency-exit area. The system gives
the floor-level illumination of the passenger aisles and escape routes in
the event that smoke obscures normal emergency lighting. The
photoluminescent marking system supplies sufficient light for eight hours
in a dark area when it is fully charged. When the system is fully
discharged, a charge time of at least ten minutes with full brightness of
the cabin lighting is necessary.

D. Integrated Escape Slide Lights


The escape slide lights are integrated in the escape slides. They come on
when the escape slides are deployed.



EFF :

ALL  33-50-00

Page 2
Feb 01/07
 
IAC 
**ON A/C ALL

3. __________________
System Description

A. General
The cabin emergency-lighting system is supplied with power, when the AC
normal busbar and the DC essential busbar are energized and the circuit
breakers are closed.
You can control the cabin emergency-lighting system with the control
switch EMER EXIT LT, installed in the cockpit. The pushbutton EMERG ON,
installed on the FAP, is connected in parallel to the control switch EMER
EXIT LT. The control switch EMER EXIT LT 4 WL has these three positions:
- OFF
- ARM
- ON
Each of the set positions cause the cabin emergency-lighting system to
operate in a different way.

(1) OFF Position


The cabin emergency lighting system is disarmed.

(2) ARM Position


The cabin emergency lighting system is set to the Automatic Mode. All
cabin emergency lights are off as long as no failure in the aircraft
power supply system occurs.

(3) ON Position
The cabin emergency lighting system is activated; all cabin emergency
lights are on. The lights are supplied by the DC essential busbar or,
in case of a DC essential busbar failure, by the EPSU batteries.

4. Power
____________
Supply
The emergency lighting system is supplied with 115 V AC from the normal
busbar 103XP-B and with 28 V DC from the essential busbar 801PP. The circuit
breakers 1WL and 2WL are installed on the circuit breaker panel 49VU. The
circuit breaker 3WL is installed on circuit breaker panel 122VU. When the DC
essential aircraft power supply is not available, the integrated batteries
of the EPSUs supply the cabin emergency lighting system. They can supply the
system for a least 10 minutes.

5. _________
BITE Test



EFF :

ALL  33-50-00

Page 3
Feb 01/07
R  
IAC 
**ON A/C 001-012, 014-099,

A. General
Each EPSU has two different integrated BITE functions:
- A system test
- A battery capacity test
The EPSUs have an interface to the CIDS to read the BITE results of a
system test and a battery capacity test.

(1) System Test


The system test monitors the subsequent functions:
- The aircraft AC power supply
- The aircraft DC power supply
- A short circuit on each output
- An overvoltage on each output
- The output voltage of the battery pack
- The battery heating device
- The proper function of the EPSU logic and switching circuits
- If the connected loads are in the pre-determined values
The system test has a limit of 20 seconds to prevent discharge of the
battery pack.

(2) Battery Capacity Test


The battery capacity test monitors:
- If the capacity of each EPSU battery is sufficient enough to supply
its emergency lights for at least 10 minutes
- If the loss of the capacity of each battery, between two
consecutive battery capacity tests, is smaller than 0.40 Ah
It can take up to three hours to complete the battery capacity test.

R **ON A/C 101-199, 901-999,

A. General
Each EPSU has two different integrated BITE functions:
- A system test
- A battery capacity test
The EPSUs have an interface to the CIDS to read the BITE results of a
system test and a battery capacity test on the CFDS/MCDU.

(1) System Test


The system test monitors the subsequent functions:
- The aircraft AC power supply
- The aircraft DC power supply
- A short circuit on each output
- An overvoltage on each output



EFF :

ALL  33-50-00

Page 4
Feb 01/07
 
IAC 
- The output voltage of the battery pack
- The battery heating device
- The proper function of the EPSU logic and switching circuits
- If the connected loads are in the pre-determined values
The system test has a limit of 20 seconds to prevent discharge of the
battery pack.

(2) Battery Capacity Test


The battery capacity test monitors:
- If the capacity of each EPSU battery is sufficient enough to supply
its emergency lights for at least 10 minutes
- If the loss of the capacity of each battery, between two
consecutive battery capacity tests, is smaller than 0.40 Ah
It can take up to three hours to complete the battery capacity test.



EFF :

101-199, 901-999,  33-50-00

Page 5
Feb 01/07
 
IAC 
CABIN EMERGENCY LIGHTING - DESCRIPTION AND OPERATION
____________________________________________________

1. General
_______

R **ON A/C 001-012, 014-099, 901-999,

A. The cabin emergency-lighting system supplies power for:

- the illumination of the cabin and the exit areas in the event of a
failure of the main lighting system,

- the illumination of an exit location and an exit marking sign at each


of the passenger/crew doors and at each of the emergency exit hatches,

- the illumination of the marking system of the emergency escape path,

- the illumination of the lavatories independent of the main lighting


system of the lavatories.

- the illumination of the escape route over the wings,

- the illumination of the door escape-slides and the emergency-exit


escape-slides,

- the illumination of the emergency-escape hatch-handles.

R **ON A/C 101-199,

R A. The cabin emergency-lighting system supplies power for:


R
R - the illumination of the cabin and the exit areas in the event of a
R failure of the main lighting system,
R
R - the illumination of an exit location and an exit marking sign at each
R of the passenger/crew doors and at each of the emergency exit doors,
R
R - the illumination of the marking system of the emergency escape path,
R
R - the illumination of the lavatories independent of the main lighting
R system of the lavatories,
R
R - the illumination of the door escape slides.



EFF :

ALL  33-51-00

Page 1
Feb 01/07
 
IAC 
R **ON A/C ALL

2. __________________
Component Location

**ON A/C 001-012, 014-099,

(Ref. Fig. 001, 002, 003)

-------------------------------------------------------------------------------
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
10WL POWER SUPPLY UNIT-EMERGENCY 221BC 221 831 33-51-38
11WL POWER SUPPLY UNIT-EMERGENCY 241KW 241 831 33-51-38
12WL POWER SUPPLY UNIT-EMERGENCY 242KW 242 831 33-51-38
13WL POWER SUPPLY UNIT-EMERGENCY 261KW 261 832 33-51-38
20WL LIGHT-EMERGENCY, CABIN 222 841 33-51-11
21WL LIGHT-EMERGENCY, CABIN 221 831 33-51-11
22WL2 LIGHT-EMERGENCY, CABIN 232 831 33-51-11
22WL4 LIGHT-EMERGENCY, CABIN 242 831 33-51-11
22WL6 LIGHT-EMERGENCY, CABIN 242 832 33-51-11
22WL8 LIGHT-EMERGENCY, CABIN 252 832 33-51-11
22WL10 LIGHT-EMERGENCY, CABIN 252 832 33-51-11
23WL1 LIGHT-EMERGENCY, CABIN 231 831 33-51-11
23WL3 LIGHT-EMERGENCY, CABIN 231 831 33-51-11
23WL5 LIGHT-EMERGENCY, CABIN 241 832 33-51-11
23WL7 LIGHT-EMERGENCY, CABIN 251 832 33-51-11
23WL9 LIGHT-EMERGENCY, CABIN 251 832 33-51-11
32WL LIGHT-EMERGENCY, CABIN 262 842 33-51-11
33WL LIGHT-EMERGENCY, CABIN 261 832 33-51-11
40WL SIGN-EXIT MARKING 222 841 33-51-16
41WL SIGN-EXIT MARKING 221 831 33-51-16
42WL SIGN-EXIT MARKING 242 841 33-51-16
43WL SIGN-EXIT MARKING 241 831 33-51-16
44WL SIGN-EXIT MARKING 262 842 33-51-16
45WL SIGN-EXIT MARKING 261 832 33-51-16
50WL SIGN-EXIT LOCATION, 1 SIDED 221 831 33-51-17
51WL SIGN-EXIT LOCATION, 1 SIDED 241 831 33-51-17
52WL SIGN-EXIT LOCATION, 1 SIDED 261 832 33-51-17
53WL SIGN-EXIT LOCATION, 1 SIDED 241 831 33-51-17
60WL LIGHT-EMERGENCY, OVERWING 242 831 33-51-15
61WL LIGHT-EMERGENCY, OVERWING 241 831 33-51-15
62WL LIGHT-EMERGENCY, OVERWING 242 831 33-51-15
63WL LIGHT-EMERGENCY, OVERWING 241 831 33-51-15
70WL1 ESCAPE HATCH HANDLE LIGHT 241 831 33-51-11


R

EFF :

ALL  33-51-00

Page 2
Feb 01/07
 
IAC 
Cabin Emergency Lighting - Component Location
Figure 001


R

EFF :

001-012, 014-099,  33-51-00

Page 3
Feb 01/07
 
IAC 
Cabin Emergency Lighting - Component Location
R Figure 001A


R

EFF :

101-199, 901-999,  33-51-00

Page 4
May 01/07
 
IAC 
INTENTIONALLY BLANK


R



 33-51-00

Page 5
May 01/07
 
IAC 
Cabin Emergency Lighting - Component Location
Figure 002 (SHEET 1)


R

EFF :

001-012, 014-099,  33-51-00

Page 6
Aug 01/07
 
IAC 
Cabin Emergency Lighting - Component Location
Figure 002 (SHEET 2)


R

EFF :

001-012, 014-099,  33-51-00

Page 7
Aug 01/07
 
IAC 
Cabin Emergency Lighting - Component Location
Figure 002 (SHEET 3)


R

EFF :

001-012, 014-099,  33-51-00

Page 8
Aug 01/07
 
IAC 
R Cabin Emergency Lighting - Component Location
R Figure 002A



EFF :

101-199,  33-51-00

Page 9
Aug 01/07
 
IAC 
Cabin Emergency Lights - Component Location
R Figure 002B


R

EFF :

901-901,  33-51-00

Page 10
May 01/07
 
IAC 
R Cabin Emergency Lighting - Component Location
R Figure 002C


R

EFF :

902-999,  33-51-00

Page 11
Aug 01/07
 
IAC 
Lavatory Auxiliary Lights - Component Location
Figure 003



EFF :

001-012, 014-099,  33-51-00

Page 12
Aug 01/07
R  
IAC 
-------------------------------------------------------------------------------
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
70WL2 ESCAPE HATCH HANDLE LIGHT 242 831 33-51-11
70WL3 ESCAPE HATCH HANDLE LIGHT 241 831 33-51-11
70WL4 ESCAPE HATCH HANDLE LIGHT 242 831 33-51-11
80WL LIGHT-AUXILIARY, LAVATORY 223 831 33-51-14
81WL LIGHT-AUXILIARY, LAVATORY 263 832 33-51-14
83WL LIGHT-AUXILIARY, LAVATORY 264 842 33-51-14
90WL1 SIGN-EXIT MARKING, WALL MOUNTED 221 831 33-51-13
90WL2 SIGN-EXIT MARKING, WALL MOUNTED 222 841 33-51-13
90WL3 SIGN-EXIT MARKING, WALL MOUNTED 241 831 33-51-13
90WL4 SIGN-EXIT MARKING, WALL MOUNTED 242 831 33-51-13
90WL5 SIGN-EXIT MARKING, WALL MOUNTED 241 831 33-51-13
90WL6 SIGN-EXIT MARKING, WALL MOUNTED 242 831 33-51-13
90WL7 SIGN-EXIT MARKING, WALL MOUNTED 261 832 33-51-13
90WL8 SIGN-EXIT MARKING, WALL MOUNTED 262 842 33-51-13
100WL1 LIGHT-EMERGENCY, SEAT MOUNTED 200 831 33-51-19
100WL2 LIGHT-EMERGENCY, SEAT MOUNTED 200 831 33-51-19
100WL3 LIGHT-EMERGENCY, SEAT MOUNTED 200 831 33-51-19
100WL4 LIGHT-EMERGENCY, SEAT MOUNTED 200 831 33-51-19
100WL5 LIGHT-EMERGENCY, SEAT MOUNTED 200 832 33-51-19
100WL6 LIGHT-EMERGENCY, SEAT MOUNTED 200 832 33-51-19
100WL7 LIGHT-EMERGENCY, SEAT MOUNTED 200 832 33-51-19
100WL8 LIGHT-EMERGENCY, SEAT MOUNTED 200 832 33-51-19
100WL9 LIGHT-EMERGENCY, SEAT MOUNTED 200 832 33-51-19
100WL10 LIGHT-EMERGENCY, SEAT MOUNTED 200 832 33-51-19
100WL11 LIGHT-EMERGENCY, SEAT MOUNTED 200 832 33-51-19
101WL1 LIGHT-EMERG. EXIT LOC., SEAT MOUNTED 200 831 33-51-18
101WL2 LIGHT-EMERG. EXIT LOC., SEAT MOUNTED 200 831 33-51-18
101WL3 LIGHT-EMERG. EXIT LOC., SEAT MOUNTED 200 831 33-51-18
101WL4 LIGHT-EMERG. EXIT LOC., SEAT MOUNTED 200 831 33-51-18
150WL1 LIGHT-EMERGENCY, WALL MOUNTED 200 831 33-51-19
361WL1 LIGHT-EMERGENCY, WALL MOUNTED 200 832 33-51-19
361WL2 LIGHT-EMERGENCY, WALL MOUNTED 200 832 33-51-19


R

EFF :

001-012, 014-099,  33-51-00

Page 13
Aug 01/07
 
IAC 
**ON A/C 101-199,

(Ref. Fig. 001A, 002A, 003A, 004, 005, 006, 007)

-------------------------------------------------------------------------------
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
10WL POWER SUPPLY UNIT-EMERGENCY 221BC 221 831 33-51-38
11WL POWER SUPPLY UNIT-EMERGENCY 251KC 251 834 33-51-38
12WL POWER SUPPLY UNIT-EMERGENCY 251KC 221 834 33-51-38
13WL POWER SUPPLY UNIT-EMERGENCY 33WR 260 832 33-51-38
14WL POWER SUPPLY UNIT-EMERGENCY 231JC 231 833 33-51-38
15WL POWER SUPPLY UNIT-EMERGENCY 231JC 231 833 33-51-38
20WL LIGHT-EMERGENCY, CABIN 222 841 33-51-11
21WL LIGHT-EMERGENCY, CABIN 221 831 33-51-11
32WL LIGHT-EMERGENCY, CABIN 262 842 33-51-11
33WL LIGHT-EMERGENCY, CABIN 261 832 33-51-11
34WL LIGHT-EMERGENCY, CABIN 232 843 33-51-11
35WL LIGHT-EMERGENCY, CABIN 231 833 33-51-11
36WL LIGHT-EMERGENCY, CABIN 252 844 33-51-11
37WL LIGHT-EMERGENCY, CABIN 251 834 33-51-11
40WL SIGN-EXIT MARKING 222 841 33-51-16
41WL SIGN-EXIT MARKING 221 831 33-51-16
42WL SIGN-EXIT MARKING 252 844 33-51-16
43WL SIGN-EXIT MARKING 251 834 33-51-16
44WL SIGN-EXIT MARKING 262 842 33-51-16
45WL SIGN-EXIT MARKING 261 832 33-51-16
46WL SIGN-EXIT MARKING 232 843 33-51-16
47WL SIGN-EXIT MARKING 231 833 33-51-16
50WL SIGN-EXIT LOCATION, 1 SIDED 221 831 33-51-17
51WL SIGN-EXIT LOCATION, 1 SIDED 251 834 33-51-17
52WL SIGN-EXIT LOCATION, 1 SIDED 261 832 33-51-17
53WL SIGN-EXIT LOCATION, 1 SIDED 251 834 33-51-17
54WL SIGN-EXIT LOCATION, 1 SIDED 231 833 33-51-17
55WL SIGN-EXIT LOCATION, 1 SIDED 231 833 33-51-17
90WL1 SIGN-EXIT MARKING, WALL MOUNTED 221 831 33-51-13
90WL2 SIGN-EXIT MARKING, WALL MOUNTED 222 841 33-51-13
90WL3 SIGN-EXIT MARKING, WALL MOUNTED 231 833 33-51-13
90WL4 SIGN-EXIT MARKING, WALL MOUNTED 232 843 33-51-13
90WL5 SIGN-EXIT MARKING, WALL MOUNTED 251 834 33-51-13
90WL6 SIGN-EXIT MARKING, WALL MOUNTED 252 844 33-51-13
90WL7 SIGN-EXIT MARKING, WALL MOUNTED 261 832 33-51-13
90WL8 SIGN-EXIT MARKING, WALL MOUNTED 262 842 33-51-13
200WL LIGHT-EMERGENCY, CABIN 231 831 33-51-11
201WL LIGHT-EMERGENCY, CABIN 231 831 33-51-11



EFF :

101-199,  33-51-00

Page 14
Aug 01/07
R  
IAC 
Lavatory Auxiliary Lights - Component Location
Figure 003A


R

EFF :

101-199,  33-51-00

Page 15
Aug 01/07
 
IAC 
Lavatory Auxiliary Lights - Component Location
Figure 003B


R

EFF :

901-999,  33-51-00

Page 16
Aug 01/07
 
IAC 
Emergency Power Supply Unit - Component Location
Figure 004


R

EFF :

101-199,  33-51-00

Page 17
Aug 01/07
 
IAC 
Emergency Power Supply Unit - Component Location
Figure 004A


R

EFF :

901-999,  33-51-00

Page 18
Aug 01/07
 
IAC 
Exit Marking and Exit Location Signs - Component Location
Figure 005


R

EFF :

101-199,  33-51-00

Page 19
Aug 01/07
 
IAC 
Exit Marking and Exit Location Signs - Component Location
Figure 005A


R

EFF :

901-999,  33-51-00

Page 20
Aug 01/07
 
IAC 
Wall Mounted Exit Marking Signs - Component Location
Figure 006


R

EFF :

101-199,  33-51-00

Page 21
Aug 01/07
 
IAC 
Wall Mounted Exit Marking Signs - Component Location
Figure 006A


R

EFF :

901-999,  33-51-00

Page 22
Aug 01/07
 
IAC 
Photoluminescent Light Strips - Component Location
Figure 007


R

EFF :

101-199,  33-51-00

Page 23
Aug 01/07
 
IAC 
-------------------------------------------------------------------------------
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
202WL LIGHT-EMERGENCY, CABIN 231 833 33-51-11
203WL LIGHT-EMERGENCY, CABIN 231 833 33-51-11
204WL LIGHT-EMERGENCY, CABIN 241 833 33-51-11
205WL LIGHT-EMERGENCY, CABIN 241 834 33-51-11
206WL LIGHT-EMERGENCY, CABIN 251 834 33-51-11
207WL LIGHT-EMERGENCY, CABIN 251 834 33-51-11
208WL LIGHT-EMERGENCY, CABIN 251 834 33-51-11
209WL LIGHT-EMERGENCY, CABIN 251 832 33-51-11
210WL LIGHT-EMERGENCY, CABIN 251 832 33-51-11
22LQ1 LIGHT-AUXILIARY, LAVATORY 221 831 33-51-14
22LQ4 LIGHT-AUXILIARY, LAVATORY 261 832 33-51-14
22LQ9 LIGHT-AUXILIARY, LAVATORY 251 832 33-51-14
22LQ10 LIGHT-AUXILIARY, LAVATORY 252 842 33-51-14
PHOTOLUMINESCENT-STRIP, FLOOR-PROXIMITY 200 831 33-51-21
EMERGENCY-ESCAPE-PATH-MARKING

**ON A/C 901-901,

(Ref. Fig. 001A, 002B, 003B, 004A, 005A, 006A, 007A, 008)

-------------------------------------------------------------------------------
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
10WL POWER SUPPLY UNIT-EMERGENCY 221BC 221 831 33-51-38
11WL POWER SUPPLY UNIT-EMERGENCY 241KW 241 831 33-51-38
12WL POWER SUPPLY UNIT-EMERGENCY 242KW 242 831 33-51-38
13WL POWER SUPPLY UNIT-EMERGENCY 33WR 260 832 33-51-38
20WL LIGHT-EMERGENCY, CABIN 222 841 33-51-11
21WL LIGHT-EMERGENCY, CABIN 221 831 33-51-11
32WL LIGHT-EMERGENCY, CABIN 262 842 33-51-11
33WL LIGHT-EMERGENCY, CABIN 261 832 33-51-11
40WL SIGN-EXIT MARKING 222 841 33-51-16
41WL SIGN-EXIT MARKING 221 831 33-51-16
42WL SIGN-EXIT MARKING 242 841 33-51-16
43WL SIGN-EXIT MARKING 241 831 33-51-16
44WL SIGN-EXIT MARKING 262 842 33-51-16
45WL SIGN-EXIT MARKING 261 832 33-51-16
50WL SIGN-EXIT LOCATION, 1 SIDED 221 831 33-51-17
51WL SIGN-EXIT LOCATION, 1 SIDED 241 831 33-51-17
52WL SIGN-EXIT LOCATION, 1 SIDED 261 832 33-51-17
53WL SIGN-EXIT LOCATION, 1 SIDED 241 831 33-51-17


R

EFF :

101-199, 901-901,  33-51-00

Page 24
Aug 01/07
 
IAC 
Photoluminescent Light Strips - Component Location
Figure 007A


R

EFF :

901-901,  33-51-00

Page 25
Aug 01/07
 
IAC 
R Photoluminescent Light Strips - Component Location
R Figure 007B


R

EFF :

902-999,  33-51-00

Page 26
Aug 01/07
 
IAC 
Overwing Emergency Light and Escape Hatch Handle Light - Component Location
Figure 008



EFF :

901-999,  33-51-00

Page 27
Aug 01/07
R  
IAC 
-------------------------------------------------------------------------------
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
60WL LIGHT-EMERGENCY, OVERWING 242 831 33-51-15
61WL LIGHT-EMERGENCY, OVERWING 241 831 33-51-15
62WL LIGHT-EMERGENCY, OVERWING 242 831 33-51-15
63WL LIGHT-EMERGENCY, OVERWING 241 831 33-51-15
70WL1 ESCAPE HATCH HANDLE LIGHT 241 831 33-51-11
70WL2 ESCAPE HATCH HANDLE LIGHT 242 831 33-51-11
90WL1 SIGN-EXIT MARKING, WALL MOUNTED 221 831 33-51-13
90WL2 SIGN-EXIT MARKING, WALL MOUNTED 222 841 33-51-13
90WL3 SIGN-EXIT MARKING, WALL MOUNTED 241 831 33-51-13
90WL4 SIGN-EXIT MARKING, WALL MOUNTED 242 831 33-51-13
90WL5 SIGN-EXIT MARKING, WALL MOUNTED 261 832 33-51-13
90WL6 SIGN-EXIT MARKING, WALL MOUNTED 262 842 33-51-13
200WL LIGHT-EMERGENCY, CABIN 231 831 33-51-11
201WL LIGHT-EMERGENCY, CABIN 231 831 33-51-11
202WL LIGHT-EMERGENCY, CABIN 241 831 33-51-11
203WL LIGHT-EMERGENCY, CABIN 241 831 33-51-11
204WL LIGHT-EMERGENCY, CABIN 251 832 33-51-11
205WL LIGHT-EMERGENCY, CABIN 251 832 33-51-11
206WL LIGHT-EMERGENCY, CABIN 261 832 33-51-11
22LQ1 LIGHT-AUXILIARY, LAVATORY 221 831 33-51-14
22LQ4 LIGHT-AUXILIARY, LAVATORY 261 832 33-51-14
22LQ5 LIGHT-AUXILIARY, LAVATORY 262 842 33-51-14
PHOTOLUMINESCENT STRIP-FLOOR PROXIMITY 200 831 33-51-21
EMERGENCY ESCAPE PATH MARKING

R **ON A/C 902-999,

R (Ref. Fig. 001A, 002C, 003B, 004A, 005A, 006A, 007B, 008)

R -------------------------------------------------------------------------------
R FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
R | | | | DOOR | REF.
R -------------------------------------------------------------------------------
R 10WL POWER SUPPLY UNIT-EMERGENCY 221BC 221 831 33-51-38
R 11WL POWER SUPPLY UNIT-EMERGENCY 241KW 241 831 33-51-38
R 12WL POWER SUPPLY UNIT-EMERGENCY 242KW 242 831 33-51-38
R 13WL POWER SUPPLY UNIT-EMERGENCY 33WR 260 832 33-51-38
R 20WL LIGHT-EMERGENCY, CABIN 222 841 33-51-11
R 21WL LIGHT-EMERGENCY, CABIN 221 831 33-51-11
R 32WL LIGHT-EMERGENCY, CABIN 262 842 33-51-11
R 33WL LIGHT-EMERGENCY, CABIN 261 832 33-51-11
R 40WL SIGN-EXIT MARKING 222 841 33-51-16


R

EFF :

901-999,  33-51-00

Page 28
Aug 01/07
 
IAC 
-------------------------------------------------------------------------------
FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF.
-------------------------------------------------------------------------------
R 41WL SIGN-EXIT MARKING 221 831 33-51-16
R 42WL SIGN-EXIT MARKING 242 841 33-51-16
R 43WL SIGN-EXIT MARKING 241 831 33-51-16
R 44WL SIGN-EXIT MARKING 262 842 33-51-16
R 45WL SIGN-EXIT MARKING 261 832 33-51-16
R 50WL SIGN-EXIT LOCATION, 1 SIDED 221 831 33-51-17
R 51WL SIGN-EXIT LOCATION, 1 SIDED 241 831 33-51-17
R 52WL SIGN-EXIT LOCATION, 1 SIDED 261 832 33-51-17
R 53WL SIGN-EXIT LOCATION, 1 SIDED 241 831 33-51-17
R 60WL LIGHT-EMERGENCY, OVERWING 242 831 33-51-15
R 61WL LIGHT-EMERGENCY, OVERWING 241 831 33-51-15
R 62WL LIGHT-EMERGENCY, OVERWING 242 831 33-51-15
R 63WL LIGHT-EMERGENCY, OVERWING 241 831 33-51-15
R 70WL1 ESCAPE HATCH HANDLE LIGHT 241 831 33-51-11
R 70WL2 ESCAPE HATCH HANDLE LIGHT 242 831 33-51-11
R 90WL1 SIGN-EXIT MARKING, WALL MOUNTED 221 831 33-51-13
R 90WL2 SIGN-EXIT MARKING, WALL MOUNTED 222 841 33-51-13
R 90WL3 SIGN-EXIT MARKING, WALL MOUNTED 241 831 33-51-13
R 90WL4 SIGN-EXIT MARKING, WALL MOUNTED 242 831 33-51-13
R 90WL5 SIGN-EXIT MARKING, WALL MOUNTED 261 832 33-51-13
R 90WL6 SIGN-EXIT MARKING, WALL MOUNTED 262 842 33-51-13
R 200WL LIGHT-EMERGENCY, CABIN 231 831 33-51-11
R 201WL LIGHT-EMERGENCY, CABIN 231 831 33-51-11
R 202WL LIGHT-EMERGENCY, CABIN 241 831 33-51-11
R 203WL LIGHT-EMERGENCY, CABIN 241 831 33-51-11
R 204WL LIGHT-EMERGENCY, CABIN 251 832 33-51-11
R 205WL LIGHT-EMERGENCY, CABIN 251 832 33-51-11
R 206WL LIGHT-EMERGENCY, CABIN 261 832 33-51-11
R 22LQ1 LIGHT-AUXILIARY, LAVATORY 221 831 33-51-14
R 22LQ4 LIGHT-AUXILIARY, LAVATORY 261 832 33-51-14
R 22LQ5 LIGHT-AUXILIARY, LAVATORY 262 842 33-51-14
R PHOTOLUMINESCENT STRIP-FLOOR PROXIMITY 200 831 33-51-21
R EMERGENCY ESCAPE PATH MARKING

**ON A/C ALL

3. __________________
System Description


R

EFF :

ALL  33-51-00

Page 29
Aug 01/07
 
IAC 
**ON A/C 001-012, 014-099,

(Ref. Fig. 009, 010)

A. Emergency Lighting System


The emergency lighting system of the cabin consists of:
- fourteen 6 V cabin emergency lights,
- six 6 V exit marking signs,
- four 6 V exit location signs,
- four 6 V overwing emergency-exit lights, installed in the wing fairing,
- four emergency-power supply units,
- one 28 V auxiliary light, installed in each lavatory,
- eleven 6 V seat-mounted floor-proximity emergency-lights,
- two 6 V wall-mounted floor-proximity emergency-lights,
- eight 6 V wall-mounted exit markers,
- four 6 V seat-mounted emergency-exit location-lights.

**ON A/C 101-199,

(Ref. Fig. 009A, 010A)

A. Emergency Lighting System

The emergency lighting system of the cabin consists of:


- six emergency power-supply units
- a number of 6VDC escape slide lights as parts of the escape slides
- nineteen 6VDC cabin emergency lights
- eight 6VDC exit marking signs
- six 6VDC exit location signs
- eight 115VAC wall-mounted exit-marking signs
- four 28VDC auxiliary lights, one installed in each lavatory
- photoluminescent strips in the aisle for the marking system of the
floor-proximity emergency escape-path.

R **ON A/C 901-999,

R **ON A/C 901-901,

R (Ref. Fig. 009B)



EFF :

ALL  33-51-00

Page 30
Aug 01/07
 
IAC 
Cabin Emergency Lighting - Schematic
Figure 009


R

EFF :

001-012, 014-099,  33-51-00

Page 31/32
May 01/07
 
IAC 
INTENTIONALLY BLANK


R



 33-51-00

Page 33
May 01/07
 
IAC 
R Cabin Emergency Lighting - Schematic
R Figure 009A (SHEET 1)


R

EFF :

101-199,  33-51-00

Page 34
May 01/07
 
IAC 
R Cabin Emergency Lighting - Schematic
R Figure 009A (SHEET 2)


R

EFF :

101-199,  33-51-00

Page 35
May 01/07
 
IAC 
R Cabin Emergency Lighting - Schematic
R Figure 009A (SHEET 3)


R

EFF :

101-199,  33-51-00

Page 36
May 01/07
 
IAC 
INTENTIONALLY BLANK


R



 33-51-00

Page 37
May 01/07
 
IAC 
Cabin Emergency Lighting - Schematic
Figure 009B (SHEET 1)


R

EFF :

901-901,  33-51-00

Page 38
May 01/07
 
IAC 
Cabin Emergency Lighting - Schematic
Figure 009B (SHEET 2)


R

EFF :

901-901,  33-51-00

Page 39
May 01/07
 
IAC 
Cabin Emergency Lighting - Schematic
Figure 009B (SHEET 3)


R

EFF :

901-901,  33-51-00

Page 40
May 01/07
 
IAC 
INTENTIONALLY BLANK


R



 33-51-00

Page 41
May 01/07
 
IAC 
R Cabin Emergency Lighting - Schematic
R Figure 009C (SHEET 1)



EFF :

902-999,  33-51-00

Page 42
Aug 01/07
 
IAC 
R Cabin Emergency Lighting - Schematic
R Figure 009C (SHEET 2)



EFF :

902-999,  33-51-00

Page 43
Aug 01/07
 
IAC 
R Cabin Emergency Lighting - Schematic
R Figure 009C (SHEET 3)



EFF :

902-999,  33-51-00

Page 44
Aug 01/07
 
IAC 
Lavatory Auxiliary Lights - Schematic
Figure 010


R

EFF :

001-012, 014-099,  33-51-00

Page 45
May 01/07
 
IAC 
R Lavatory Auxiliary Lights - Schematic
R Figure 010A


R

EFF :

101-199,  33-51-00

Page 46
May 01/07
 
IAC 
R **ON A/C 902-999,

R (Ref. Fig. 009C)

R **ON A/C 901-999,

R (Ref. Fig. 010B)

A. Emergency Lighting System

The emergency lighting system of the cabin consists of:


- four emergency power-supply units,
- eleven 6VDC cabin emergency lights,
- two 6VDC escape hatch-handle lights,
- six 6VDC exit marking signs,
- four 6VDC exit location signs,
- four 6VDC overwing emergency-exit lights, installed in the wing
fairing,
- a number of 6VDC escape slide lights as parts of the escape slides,
- six 6VDC wall-mounted exit-marking signs,
- three 28VDC auxiliary lights, one installed in each lavatory.
- photoluminescent strips in the aisle for the marking system of the
floor-proximity emergency escape-path,
R

**ON A/C ALL

4. ____________
Power Supply

**ON A/C 001-012, 014-099,

The 28VDC essential busbar 801PP and the 115VAC normal busbar 103XP supply
the Emergency Power Supply Units (EPSUs). The EPSUs convert 28VDC into 6VDC
to operate the lights in the system. A battery in each EPSU is charged
continuously when the essential busbar is energized and the circuit breakers
are closed. Each of the four EPSUs supplies electrical power to different
emergency lights and signs. The emergency lights and signs are always
supplied with power, even if the aircraft has crashed and the fuselage has
broken. This is because the four EPSUs are installed in different places in
the cabin.


R

EFF :

ALL  33-51-00

Page 47
Aug 01/07
 
IAC 
Lavatory Auxiliary Lights - Schematic
Figure 010B


R

EFF :

901-999,  33-51-00

Page 48
Aug 01/07
 
IAC 
The EMER EXIT LT switch 4WL on the overhead panel 25VU controls the
emergency lighting system. Self-monitoring circuit breakers 1WL, 2WL and 3WL
protect the system from too much current flow. The EMER EXIT LT switch 4WL
has three positions, OFF, ARM and ON. Each of these positions gives a
discrete ground signal to all EPSUs. The EPSUs also monitor the correct
voltage of the AC and DC busbars. When the voltage on these busbars falls
below a specified level, the emergency lighting automatically comes on. This
is when the EMER EXIT LT switch 4WL is in the ARM position.
When only the AC normal busbar fails:
- the 28VDC essential busbar supplies the emergency lighting system through
the 28VDC/6VDC converter in each EPSU.
When the 28VDC essential busbar fails:
- the internal batteries in the EPSUs supply the emergency lighting system.

When the EMER EXIT LT switch 4WL is in the ON position:


- the converters or the internal batteries in the EPSUs supply the emergency
lighting system.

When the LIGHT EMER pushbutton switch and its integral light on the forward
attendant panel 120RH are on:
- the converters or the internal batteries in the EPSUs supply the emergency
lighting system.

An open or short circuit in the control lines causes the emergency lighting
to come on. The internal test program in the EPSUs finds defects in the load
circuits.

**ON A/C 101-199, 901-999,

The 28VDC essential busbar 801PP and the 115VAC normal busbar 103XP supply
the Emergency Power Supply Units (EPSUs). The EPSUs 10WL thru 13WL convert
28VDC into 6VDC to operate the lights in the normal emergency light system
and the marking system of the emergency escape path. A battery in each EPSU
is charged continuously when the essential busbar is energized and the
circuit breakers are closed. Each of the EPSUs supplies electrical power to
different emergency lights and signs. The emergency lights and signs are
always supplied with power, even if the aircraft has crashed and the
fuselage has broken. This is because the four EPSUs are installed in
different places in the cabin.
The EMER EXIT LT switch 4WL on the overhead panel 25VU controls the
emergency lighting system. Self-monitoring circuit breakers 1WL, 2WL and 3WL
protect the system from too much current flow. The EMER EXIT LT switch 4WL
has three positions, OFF, ARM and ON. Each of these positions gives a
discrete ground signal to all EPSUs. The EPSUs also monitor the correct
voltage of the AC and DC busbars. When the voltage on these busbars falls



EFF :

ALL  33-51-00

Page 49
Aug 01/07
R  
IAC 
below a specified level, the emergency lighting automatically comes on. This
is when the EMER EXIT LT switch 4WL is in the ARM position.
When only the AC normal busbar fails:
- the 28VDC essential busbar supplies the emergency lighting system through
the 28VDC/6VDC converter in each EPSU.
When the 28VDC essential busbar fails:
- the internal batteries in the EPSUs supply the emergency lighting system.

When the EMER EXIT LT switch 4WL is in the ON position:


- the converters or the internal batteries in the EPSUs supply the emergency
lighting system.

When the EMER pushbutton switch and its integral light on the flight
attendant panel 120RH are on:
- the converters or the internal batteries in the EPSUs supply the emergency
lighting system.

An open or short circuit in the control lines causes the emergency lighting
to come on. The internal test program in the EPSUs finds defects in the load
circuits.

**ON A/C 001-012, 014-099, 901-999,

When the emergency exit hatches are open and the slides are released, the
respective overwing emergency lights and the integral lights in the
respective escape slide come on.
When the passenger/crew doors are open and the slides are armed, the
integral lights in the respective escape slide come on.

**ON A/C 101-199,

When the passenger/crew doors or the emergency exit doors are open and the
slides are armed, the integral lights in the respective escape slide come
on.

**ON A/C 001-012, 014-099,

In an emergency condition it is possible that the normal cabin


emergency-lighting system is not sufficient. This is when smoke enters the
cabin. In order to give sufficient illumination of the aisle, exits and
emergency exits, a low-level emergency-lighting system is installed. These
emergency lights are installed in selected aisle seats and at the passenger
exits. They come on when the emergency lighting system is activated.



EFF :

ALL  33-51-00

Page 50
Aug 01/07
R  
IAC 
**ON A/C 101-199, 901-999,

In an emergency condition it is possible that the normal cabin


emergency-lighting system is not sufficient. This is when smoke enters the
cabin. In order to give sufficient illumination of the aisle, exits and
emergency exits, a floor-level marking-system for the emergency escape-path
is installed.
The electrical marking system consists of a wall-mounted exit-marking sign
at each passenger/crew door and emergency exit. They come on when the
emergency lighting system is energized.
The photoluminescent marking system consists of a number of flexible
photoluminescent strips. They are installed on the floor at both sides of
the aisle.

**ON A/C ALL

When the EMER EXIT LT control switch 4WL is in the OFF position and the DC
essential busbar 801PP is energized:
- The EMER EXIT LT OFF annunciator light 5WL in the cockpit comes on.

**ON A/C 001-012, 014-099,

You can test the emergency lighting system through the Programming and Test
Panel (PTP) 110RH of the Cabin Intercommunication Data System (CIDS).
There are two tests :
- the BAT test indicates the battery capacity condition of the emergency
power-supply units 10WL thru 13WL,
- the SYS test indicates the condition of the internal loads, the external
loads and the battery charge limiter of the emergency power-supply units
10WL thru 13WL.
Internal loads are all electrical loads located inside the cabin and
served by these emergency power-supply units.
External loads are all electrical loads located outside the cabin and
served by these emergency power-supply units.

**ON A/C 101-199, 901-999,

You can test the emergency lighting system through the Centralized Fault
Display System/Multipurpose Control and Display Unit (CFDS/MCDU).
There are two tests :
- the BAT test indicates the battery capacity condition of the emergency
power-supply units 10WL thru 13WL,



EFF :

ALL  33-51-00

Page 51
Aug 01/07
R  
IAC 
- the SYS test indicates the condition of the internal loads, the external
loads and the battery charge limiter of the emergency power-supply units
10WL thru 13WL.
Internal loads are all electrical loads located inside the cabin and
served by these emergency power-supply units.
External loads are all electrical loads located outside the cabin and
served by these emergency power-supply units.

**ON A/C 001-012, 014-099,

Before you start the BAT test, you must select the applicable code on the
PTP 110RH. A note BATTERY TEST ACTIVATE comes on on the PTP display. Two
hours could be necessary to complete the test. When the TEST EMER LIGHT BAT
membrane switch on the PTP 110RH in the cabin is pushed:
- a Light Emitting Diode (LED) in the TEST EMER LIGHT BAT membrane switch
comes on to show the start of the battery test,
- the BAT OK annunciator light adjacent to the membrane switch comes on when
the battery test in all the power supply units is completed.
When the test is completed, an acknowledge code is selected on the PTP. The
LED in the TEST EMER LIGHT BAT membrane switch and the BAT OK annunciator
light go off.
When the TEST EMER LIGHT SYS membrane switch on the programming and test
panel 110RH is pushed:
- the SYS OK annunciator light adjacent to the membrane switch comes on when
the system test of all power supply units is completed.

**ON A/C 001-012, 014-099, 901-999,

The exit location signs, the exit marking signs and the escape hatch-handle
lights come on automatically when the NO SMOKING signs come on, or if
selected, when the landing gear extends.

**ON A/C 101-199,

The exit location signs and the exit marking signs switch on automatically
when the NO SMOKING signs come on, or if selected, when the landing gear
extends.

**ON A/C 001-012, 014-099,

One 28VDC auxiliary light is installed in each lavatory. The light is


permanently on when the essential busbar 801PP is energized and the circuit
breaker 79WL is closed.



EFF :

ALL  33-51-00

Page 52
Aug 01/07
R  
IAC 
**ON A/C 101-199, 901-999,

One 28VDC auxiliary light is installed in each lavatory. The light is


permanently on when the essential busbar 401PP is energized and the circuit
breaker 79WL is closed.

**ON A/C ALL

The circuit breakers used in the emergency lighting system are a special
type. When a circuit breaker is open a pair of contacts closes to complete
the monitoring circuit (Ref. 31-59-00).

5. _____________________
Component Description

**ON A/C 001-012, 014-099,

(Ref. Fig. 011)

A. Emergency Power-Supply Unit


The emergency power-supply units supply different lights. These lights
are exit signs, cabin emergency lights, overwing emergency lights, escape
slide lights, floor proximity lights and emergency-escape hatch-handle
lights.

(1) The emergency power-supply unit consists of:

(a) Electronic logic and switching circuits.

(b) A 28VDC/6VDC converter which supplies the loads whenever the


essential busbar is energized and the emergency lighting system
is activated.

(c) A 6VDC battery supplies the loads whenever the system is not
selected OFF and the power supply from the essential busbar is
not available. The essential busbar charges the battery through
the 28VDC/6VDC unit converter. Whenever the ambient temperature
falls below +20 DEG. C (68 DEG. F), the 28VDC essential busbar
provides electrical heating for the battery. The battery is
changed without removal of the emergency power-supply unit.

(d) A test circuit tests the condition of the unit battery, the unit
logic and the related loads. The battery test procedure starts
after coding selection when the TEST EMER LIGHT BAT membrane
switch on the programming and test panel 110RH (CIDS) is pushed.


R

EFF :

ALL  33-51-00

Page 53
Aug 01/07
 
IAC 
Emergency Power-Supply Unit
Figure 011


R

EFF :

001-012, 014-099,  33-51-00

Page 54
Aug 01/07
 
IAC 
If all batteries are serviceable, the BAT OK annunciator light
adjacent to the membrane switch comes on. The system test
procedure starts when the EMER LIGHT SYS membrane switch on the
programming and test panel 110RH is pushed. The test circuit
carries out an interrogation of the units and monitors the output
current.
If all units are serviceable the SYS OK annunciator light
adjacent to the membrane switch comes on. This test loop
completes only when unit output currents are within the expected
value. An individual test on each emergency power-supply unit
must be carried out when either the BAT OK or SYS OK annunciator
light does not come on. The individual test starts when the
pushbutton on the unit is pushed. A defective unit will cause a
red LED on the unit to come on. A green light in the LED
indicates a serviceable emergency power-supply unit.
There are three pairs of red and green LED. One pair provides
indication of defects in the external loads. One pair provides
indication of defects in the internal loads. One pair provides
indication of defects in the battery. Each output is separately
fused. The fuses are installed on top of the emergency
power-supply unit.

**ON A/C 101-199,

(Ref. Fig. 011A)

A. Emergency Power-Supply Unit


The emergency power-supply units supply different lights. These lights
are exit signs, cabin emergency lights and escape slide lights.

(1) The emergency power-supply unit has:

(a) Electronic logic and switching circuits.

(b) A 28VDC/6VDC converter which supplies the loads when the


essential busbar is energized and the emergency lighting system
is activated.

(c) A 6VDC battery which supplies the loads when the system is not
selected OFF and the power supply from the essential busbar is
not available. The essential busbar charges the battery through
the 28VDC/6VDC unit converter. When the ambient temperature falls
below +20 DEG. C (68 DEG. F) the 28VDC essential busbar gives
electrical heating for the battery. The battery can be replaced
without removal of the emergency power-supply unit.


R

EFF :

001-012, 014-099, 101-199,  33-51-00

Page 55
Aug 01/07
 
IAC 
Emergency Power-Supply Unit
Figure 011A



EFF :

101-199, 901-999,  33-51-00

Page 56
Aug 01/07
R  
IAC 
(d) A test circuit which tests the condition of the battery unit, the
unit logic and the related loads.
The battery test procedure starts after selection of the EPSU BAT
CAP TEST on the CIDS page of the MCDU/CFDS. If all the batteries
are serviceable, the TEST OK legend shows on the MCDU.
The system test procedure starts after selection of the EPSU SYS
R TEST on the CIDS page of the MCDU/CFDS. The test monitors the
R circuits of the EPSUs and the output currents.
If all the units are serviceable the TEST OK legend shows on the
MCDU. This test loop is completed only when all the unit output
currents are in the correct tolerance.
You must do a test of each emergency power-supply unit when the
EPSU BAT CAP TEST or the EPSU SYS TEST thru the CFDS/MCDU do not
give the correct results.
The isolated test starts when you push the TEST membrane switch
on the EPSU. A defective emergency lighting system will cause a
red LED on the EPSU to come on. The green LED SYSTEM OK on the
EPSU shows a serviceable emergency lighting system.
The four red LEDs show the indication of defects:
- in the exterior lights (external loads),
- in the interior lights (internal loads),
- in the battery,
- in the unit.
Each output has its own fuse. The fuses are installed in the
EPSU.

**ON A/C 901-999,

(Ref. Fig. 011A)

A. Emergency Power-Supply Units

The EPSUs supply different lights and signs:


- cabin emergency lights,
- escape hatch-handle lights,
- exit location signs,
- exit marking signs,
- wall-mounted exit-marking signs,
- overwing emergency lights,
- escape slide lights.



EFF :

101-199, 901-999,  33-51-00

Page 57
Feb 01/08
 
IAC 
(1) Each EPSU consists of the subsequent:

(a) Electronic logic and switching circuits.

(b) A 28VDC/6VDC converter which supplies the loads whenever the


essential busbar is energized and the emergency lighting system
is activated.

(c) A 6VDC battery supplies the loads whenever the system is not
selected OFF and the power supply from the essential busbar is
not available. The essential busbar charges the battery through
the 28VDC/6VDC unit converter. Whenever the ambient temperature
falls below +20 DEG. C (68 DEG. F) the 28VDC essential busbar
provides electrical heating for the battery. The battery could be
replaced without removal of the emergency power-supply unit.

(d) A test circuit tests the condition of the battery unit, the unit
logic and the related loads. The battery test procedure starts
after coding selection when the EPSU BAT CAP TEST on the CIDS
page of the MCDU/CFDS is selected. If all batteries are
serviceable, the TEST OK legend is shown on the MCDU.
R The system test procedure starts when EPSU SYS TEST on the CIDS
R page of the MCDU/CFDS is selected. The test circuit carries out
an interrogation of the units and monitors the output current.
If all units are serviceable the TEST OK legend is shown on the
MCDU. This test loop completes only when all unit output currents
are within the expected value. An individual test on each
emergency power-supply unit must be carried out when the EPSU BAT
CAP TEST or the EPSU SYS TEST thru the CFDS/MCDU fails.
The isolated test starts when you push the TEST membrane switch
on the EPSU. A defective emergency lighting system will cause a
red LED on the EPSU to come on. The green LED SYSTEM OK on the
EPSU shows a serviceable emergency lighting system.
The four red LEDs show the indication of defects:
- in the exterior lights (external loads),
- in the interior lights (internal loads),
- in the battery,
- in the unit.
Each output has its own fuse. The fuses are installed in the
EPSU.



EFF :

901-999,  33-51-00

Page 58
Feb 01/08
 
IAC 
**ON A/C 001-012, 014-099,

B. Exit Lights

(1) The exit signs consist of a plastic case housing, a lens and a number
of 6VDC lamps connected in parallel. There are different types:

(a) Ceiling-mounted exit location signs 50Wl and 52WL, single-sided,


one for the forward and one for the aft passenger/crew doors.

(b) Ceiling-mounted exit location signs 51WL and 53WL, single-sided,


one for each pair of the overwing emergency exits.

(c) Exit marking signs 40WL thru 45WL, single-sided, one for each
passenger/crew door and one for each pair of emergency exits.

(2) The escape hatch-handle lights 70WL1 thru 70WL4 consist of a plastic
case housing, a lens and two 6VDC lamps connected parallel. One
escape hatch-handle light is installed in each emergency exit.

C. Cabin Emergency Light

(1) Cabin emergency light units 20Wl thru 33WL consist of a housing and a
lens, containing two 6VDC lamps.

D. External Lights

(1) Overwing emergency lights 60WL thru 63WL consist of a housing, a lens
and one 6VDC lamp.

(2) Escape slide lights, integrated in the escape slides, consist of a


number of 6VDC lamps.

E. Floor Proximity Lights

(1) Seat/wall-mounted floor proximity lights consist of a housing and a


lens, containing two 6VDC lamps.

(2) Wall-mounted exit markers 90WL1 thru 90WL8, single-sided, one for
each of the passenger/crew doors and one for each of the emergency
exits.


R

EFF :

001-012, 014-099,  33-51-00

Page 59
Aug 01/07
 
IAC 
F. System Control

(1) The EMER EXIT LT switch 4WL in the cockpit is a 3-position


double-pole toggle switch. It is used to switch the emergency
lighting system on (ON position) and off (OFF position). The
emergency lighting comes on automatically when the toggle switch is
selected to ARM, if the battery busbar power fails. The toggle switch
must be pulled to make a selection. This prevents accidental system
selection.

(2) The emergency lighting system comes on when the LIGHT EMER pushbutton
on the forward attendant panel 120RH is pushed. The pushbutton
contains an integral light.

(3) The NO SMOKING switch 190RH on the overhead panel 25VU controls the
relay 8WL in the relay box 103VU. The relay 8WL switches the exit
signs on or off.

**ON A/C 101-199,

B. Cabin Emergency Lights

(1) The cabin emergency lights 20WL, 21WL, 32WL thru 37WL and 200WL thru
210WL consist of a housing, a lens and a number of LED connected in
parallel.

C. Exit Signs

(1) The exit signs consist of a plastic case housing, a lens and a number
of LED connected in parallel. There are different types:

(a) The ceiling-mounted exit-location signs 50Wl and 52WL,


single-sided, one for the forward and one for the aft
passenger/crew doors.

(b) The ceiling-mounted exit-location signs 51WL, 53WL, 54WL and


55WL, single-sided, two for each pair of emergency exit doors.

(c) The exit marking signs 40WL thru 47WL, single-sided, one for each
passenger/crew door and one for each emergency exit door.

D. External Lights

(1) The escape slide lights are integrated in the escape slides and
consist of a number of 6VDC lamps.


R

EFF :

001-012, 014-099, 101-199,  33-51-00

Page 60
Aug 01/07
 
IAC 
E. Floor Proximity Lights

(1) The wall-mounted exit-marking signs 90WL, single sided, one for each
passenger/crew door and one for each emergency exit door, contain
five 6VDC lamps.

F. System Control

(1) The EMER EXIT LT switch 4WL on the overhead panel 25VU is a
3-position double-pole toggle switch. It is used to switch the
emergency lighting system on (ON position) and off (OFF position).
The emergency lighting comes on automatically when the toggle switch
is selected to ARM, if the battery busbar power fails. The toggle
switch must be pulled to make a selection. This prevents accidental
system selection.

(2) The emergency lighting system comes on when the EMER pushbutton on
the Flight Attendant Panel (FAP) 120RH is pushed. The pushbutton
contains an internal light.

(3) The NO SMOKING switch 190RH on the overhead panel 25VU controls the
relay 8WL in the relay box 103VU. The relay 8WL switches the exit
signs on or off.

**ON A/C 901-901,

B. Cabin Emergency Lights

(1) The cabin emergency lights 20WL, 21WL, 32WL, 33WL and 200WL thru
206WL have:
- a housing
- a lens
- a number of LEDs connected in parallel.

C. Exit Signs

(1) The exit signs have:


- a plastic case housing
- a lens
- a number of LEDs connected in parallel.
There are different types:

(a) The ceiling-mounted exit-location signs 50WL and 52WL are


single-sided. There is one for the forward and one for the aft
passenger/crew doors.


R

EFF :

101-199, 901-901,  33-51-00

Page 61
Aug 01/07
 
IAC 
(b) The ceiling-mounted exit-location signs 51WL and 53WL are
single-sided for the emergency exits.

(c) The exit marking signs 40WL thru 45WL are single-sided. There is
one for each passenger/crew door and one for each emergency exit.

(2) The escape hatch-handle lights 70WL1 and 70WL2 have:


- a plastic case housing
- a lens
- two LEDs connected in parallel.
One escape hatch-handle light is installed in each emergency exit.

D. External Lights

(1) The overwing emergency lights 60WL thru 63WL have:


- a housing
- a lens
- two 6VDC lamps.

(2) The escape slide lights are a part of the escape slides. Their 6VDC
lamps are connected in parallel.

E. Floor Proximity Lights

(1) The wall-mounted exit-marking signs 90WL. There is one for each
passenger/crew door and one for each emergency exit. They have:
- a plastic case housing
- a lens
- a number of LEDs.

F. System Control

(1) The EMER EXIT LT switch 4WL on the overhead panel 25VU is a
3-position double-pole toggle switch. The positions are ON, OFF and
ARM. It sets the emergency lighting system to on or off. The
emergency lighting comes on automatically when the toggle switch is
set to ARM, if there is a failure of the battery busbar power.
The toggle switch must be pulled to make a selection. This prevents
accidental system selection.

(2) The emergency lighting system comes on when the LIGHT EMER pushbutton
switch on the forward attendant panel 120RH is pushed. The pushbutton
switch has an internal light.

(3) The NO SMOKING switch 190RH on the overhead panel 25VU controls the
relay 8WL in the relay box 103VU through the CIDS. The relay 8WL sets
the exit signs on or off.


R

EFF :

901-901,  33-51-00

Page 62
Aug 01/07
 
IAC 
**ON A/C 902-999,

B. Exit Lights

(1) The exit signs consist of a plastic case housing, a lens and a number
of LED connected in parallel. There are different types:

(a) The ceiling-mounted exit location signs 50WL and 52WL,


single-sided, one for the forward and one for the aft
passenger/crew doors.

(b) The ceiling-mounted exit location signs 51WL and 53WL,


single-sided, for the emergency exits.

(c) The exit marking signs 40WL thru 45WL, single-sided, one for each
passenger/crew door and one for each emergency exit.

(2) The escape hatch-handle lights 70WL1 and 70WL2 consist of a plastic
case housing, a lens and two LED connected in parallel.
One escape hatch-handle light is installed in each emergency exit.

C. Cabin Emergency Lights

(1) The cabin emergency lights 20WL, 21WL, 32WL, 33WL and 200WL thru
206WL consist of a housing, a lens and a number of LED connected in
parallel.

D. External Lights

(1) The overwing emergency lights 60WL thru 63WL consist of a housing, a
lens and two 6VDC lamps connected in parallel.

(2) The escape slide lights, integrated in the escape slides, consist of
a number of 6VDC lamps.

E. Floor Proximity Lights

(1) The wall-mounted exit-marking signs 90WL1 thru 90WL6, single sided,
one for each passenger/crew door and one for each emergency exit, are
modules with LED.

F. System Control

(1) The EMER EXIT LT switch 4WL on the overhead panel 25VU is a
3-position double-pole toggle switch. It is used to switch the
emergency lighting system on (ON position) and off (OFF position).
The emergency lighting comes on automatically when the toggle switch
is set to ARM, if the battery busbar power fails. The toggle switch
must be pulled to make a selection. This prevents accidental system
selection.



EFF :

902-999,  33-51-00

Page 63
Feb 01/08
R  
IAC 
(2) The emergency lighting system comes on when the EMER button on the
Flight Attendant Panel (FAP) 120RH is pushed. The button has a light.

(3) The NO SMOKING switch 190RH on the overhead panel 25VU controls the
relay 8WL in the relay box 103VU. The relay 8WL switches the exit
signs on or off.

R **ON A/C 101-199, 901-999,

R G. Photoluminescent Floor Path-Marking-System

R (1) The photoluminescent strips have no electrical power supply and are
R self-luminescent. They are charged by the cabin lights. The charging
R and discharging time can be increased and decreased by the related
R conditions:
R - Length of time of the charging
R - Light intensity during the charging
R - Color filter film (if installed).

**ON A/C ALL

6. Operation
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 009, 010, 012)

A. Operation of the Emergency Lighting System

(1) The system is supplied with power when the busbars 103XP-B and 801PP
are energized and the circuit breakers 1WL, 2WL and 3WL are closed.
With the EMER EXIT LT switch 4WL and the LIGHT EMER pushbutton switch
on the forward attendant panel 120RH in the OFF positions the
power-supply units control-line OFF is grounded. All lights and signs
are off and the battery in each power-supply unit is on charge. The
EMER EXIT LT OFF annunciator light 5WL comes on.

**ON A/C 101-199, 901-999,

**ON A/C 101-199,

(Ref. Fig. 009A)



EFF :

ALL  33-51-00

Page 64
Feb 01/08
 
IAC 
Cabin Emergency Lighting - Switching Table
Figure 012


R

EFF :

001-012, 014-099,  33-51-00

Page 65
Aug 01/07
 
IAC 
**ON A/C 901-901,

(Ref. Fig. 009B)

**ON A/C 902-999,

(Ref. Fig. 009C)

**ON A/C 101-199,

(Ref. Fig. 010A)

**ON A/C 901-999,

(Ref. Fig. 010B)

**ON A/C 101-199, 901-999,

(Ref. Fig. 012A)

A. Operation of the Emergency Lighting System

(1) The system is supplied with power when the busbars 103XP-B and 801PP
are energized and the circuit breakers 1WL, 2WL and 3WL are closed.
With the EMER EXIT LT switch 4WL and the EMER pushbutton switch on
the flight attendant panel 120RH in the OFF positions the
power-supply units control-line OFF is grounded. All lights and signs
are off and the battery in each power-supply unit is on charge. The
EMER EXIT LT OFF annunciator light 5WL comes on.

**ON A/C 001-012, 014-099, 901-999,

(2) When the NO SMOKING switch 190RH is in the ON position, independent


of the landing gear position, the power-supply units EXIT SIGN
control line is grounded. The EXIT SIGN control line is also grounded
when the NO SMOKING switch is in the AUTO position with the landing
gear extended. With a grounded EXIT SIGN control line the exit signs
and the emergency-escape hatch-handle lights come on.


R

EFF :

ALL  33-51-00

Page 66
Aug 01/07
 
IAC 
Cabin Emergency Lighting - Switching Table
Figure 012A


R

EFF :

101-199, 901-999,  33-51-00

Page 67
Aug 01/07
 
IAC 
(3) The exit signs and the emergency-escape hatch-handle lights go off
when the NO SMOKING switch 190RH is in the OFF position. The ground
signal is removed from the EXIT SIGN control line. The exit signs and
the emergency-escape hatch-handle lights also go off when the landing
gear retracts and the NO SMOKING switch 190RH is in the AUTO
position.

**ON A/C 101-199,

(2) When the NO SMOKING switch 190RH is in the ON position, independent


of the landing gear position, the power-supply units EXIT SIGN
control line is grounded. The EXIT SIGN control line is also grounded
when the NO SMOKING switch is in the AUTO position with the landing
gear extended. With a grounded EXIT SIGN control line the exit signs
come on.

(3) The exit signs go off when the NO SMOKING switch 190RH is in the OFF
position. The ground signal is removed from the EXIT SIGN control
line. The exit signs also go off when the landing gear retracts and
the NO SMOKING switch 190RH is in the AUTO position.

**ON A/C ALL

(4) With the EMER EXIT LT switch 4WL in the ARM position, the
power-supply units control-line ARM is grounded. The EMER EXIT LT OFF
annunciator light 5WL goes off. If the power supply on the 115VAC
normal busbar 103XP fails, the cabin emergency lights and the floor
proximity lights come on. The lights are supplied with power through
the 28VDC/6VDC converter in each emergency power-supply unit.

(5) If the 28VDC essential busbar voltage falls below 16VDC +/- 1VDC, the
batteries in the power supply units provide the power supply and
continue to supply the loads for at least 12 minutes.

**ON A/C 001-012, 014-099,

(6) With the EMER EXIT LT switch 4WL in the ON position, the power-supply
units control-line ON is grounded. This control line also has a
ground connection, when the LIGHT EMER pushbutton switch on the
forward attendant panel 120RH is pushed. In either case the cabin
emergency lights, the exit signs, the escape hatch-handle lights and
the floor proximity lights come on. The 28VDC/6VDC converter of the
power supply units supply these loads as long as the 28VDC essential
busbar power is available. If the essential busbar fails see above.



EFF :

ALL  33-51-00

Page 68
Aug 01/07
R  
IAC 
R **ON A/C 101-199,

R (6) With the EMER EXIT LT switch 4WL in the ON position, the emergency
R power-supply units control-line ON is grounded. This control line
R also has a ground connection, when the EMER button on the Flight
R Attendant Panel (FAP) 120RH is pushed. In each condition the cabin
R emergency lights, the exit signs and the wall-mounted exit-marking
R signs come on. The 28VDC/6VDC converter of the emergency power-supply
R units supply these loads as long as the 28VDC essential busbar power
R is available. If the essential busbar has a failure see above.

R **ON A/C 901-999,

R (6) With the EMER EXIT LT switch 4WL in the ON position, the power-supply
R units control-line ON is grounded. This control line also has a
R ground connection, when the EMER button on the Flight Attendant Panel
R (FAP) 120RH is pushed. In each condition the cabin emergency lights,
R the exit signs, the escape hatch-handle lights and the wall-mounted
R exit-marking signs come on. The 28VDC/6VDC converter of the emergency
R power-supply units supply these loads as long as the 28VDC essential
R busbar power is available. If the essential busbar has a failure see
R above.

**ON A/C 001-012, 014-099, 901-999,

(7) With the passenger/crew doors open and the escape slides armed,
independent of switch positions, the integral lights in the
respective escape slides come on.
With the emergency exit hatches removed and the escape slides
released, independent of switch positions, the integral lights in the
respective escape slides and two overwing lights at these hatches
come on.

**ON A/C 101-199,

(7) With the passenger/crew doors or the emergency exit doors open and
the escape slides armed, independent of switch positions, the
integral lights in the respective escape slides come on.



EFF :

ALL  33-51-00

Page 69
Aug 01/07
 
IAC 
**ON A/C 001-012, 014-099,

(8) With the essential busbar 801PP energized and the circuit breaker
79WL closed, a 28VDC auxiliary light comes on in each lavatory.

**ON A/C 101-199, 901-999,

(8) With the essential busbar 401PP energized and the circuit breaker
79WL closed, a 28VDC auxiliary light comes on in each lavatory.

**ON A/C 001-012, 014-099, 901-999,

(9) In the event of excessive cabin depressurization, the exit marking


signs, the exit location signs and the emergency-escape hatch-handle
lights automatically come on.

**ON A/C 101-199,

(9) In the event of excessive cabin depressurization, the exit marking


signs and the exit location signs automatically come on.

**ON A/C ALL

7. _________
BITE TEST

**ON A/C 001-012, 014-099,

A. Emergency Lighting System


An electronic test circuit energizes when the TEST EMER LIGHT SYS
membrane switch on the programming and test panel 110RH (CIDS) is pushed.
The test circuit supplies the ground for the emergency power-supply units
control line TEST and, at the same time, the circuit for the SYS OK
annunciator light.

The emergency power-supply units 10WL thru 13WL start the following
tests:
- internal logic circuits,
- battery charging and monitoring circuits,
- 28VDC power supply,
- 115VAC power supply,
- external loads and



EFF :

ALL  33-51-00

Page 70
Aug 01/07
R  
IAC 
- internal loads.

If there are no failures, the emergency power-supply unit completes the


test signal loop. When the test loops of all emergency power-supply units
are complete, the test circuit is complete and the SYS OK annunciator
light comes on.

**ON A/C 101-199, 901-999,

A. General
Each EPSU has two different integrated BITE functions:
- a system test,
- a battery capacity test.
The EPSUs have an interface to the CIDS to read the BITE results of a
system test and a battery capacity test.

(1) System Test


The system test monitors the subsequent functions:
- a short circuit on each output,
- an overvoltage on each output,
- the output voltage of the battery pack,
- the battery heating device,
- the proper function of the EPSU logic and switching circuits,
- if the connected loads are in the pre-determined values.
The pre-determined resistance values are used as reference values.
The referenced values are stored in a memory of the EPSU electronic
and monitoring circuits during a load programming (TEACH-IN)
procedure. The procedure is accomplished as follows:
- disconnect EPSU from 28 V DC aircraft power supply,
- remove EPSU battery,
- re-connect EPSU to 28 V DC aircraft power supply,
- install EPSU battery.
During the system test each EPSU measure the resistance values of its
connected loads. These measured values are compared with the
reference values.
The system test has a limit of 60 seconds to prevent discharge of the
battery pack.

**ON A/C 001-012, 014-099,

The test signal loop of the emergency power-supply unit is not


complete if there is a defect found during the tests. If the test
circuit is not complete, the SYS OK annunciator light does not come
on. The display of the programming and test panel 110RH (CIDS) shows
the messages:


R

EFF :

ALL  33-51-00

Page 71
Aug 01/07
 
IAC 
- EPSU UNIT,
- EPSU BATTERY,
- EPSU 28 VDC,
- EPSU 115 VAC,
- EPSU EXT LOAD,
- EPSU INT LOAD.

The EPSU UNIT message is shown when there is a failure in the


internal logic circuits.
The EPSU BATTERY message is shown when there is a failure in the
battery charging and monitoring circuits.
The EPSU 28 VDC or the EPSU 115 VAC messages are shown when there is
a failure in the related power supply.
The EPSU EXT LOAD or the EPSU INT LOAD messages are shown when there
are failures in the external and the internal loads. A failure is
found when the resistance values of these loads are not in their
given limits.
During the tests of the external and the internal loads and a load
programming (TEACH-IN) procedure the emergency power-supply units
switch on these loads. This tests and the TEACH-IN measure the
resistance values of the loads.
The TEACH-IN calculates the resistance limits of the loads and stores
their values in the memories of the emergency power-supply units.
Each emergency power-supply unit compares the measured values of the
test with the stored limits of the TEACH-IN.

The TEACH-IN starts automatically when:


- the 115VAC and the 28VDC power are available,
- on the forward attendant panel 120RH the LIGHT EMER pushbutton
switch is in the released position,
- on the overhead panel 25VU the EMER EXIT LT switch 4WL is in the
OFF position,
- on the overhead panel 25VU the NO SMOKING switch 190RH is in the
OFF position,
- the overwing emergency lights are off,
- the emergency power-supply unit is installed on the A/C for the
first time, or
the battery was removed for more than 5 s and is then installed
again.

(2) Not Applicable


External loads are:
- the overwing emergency lights,
- the escape slide lights.

Internal loads are:


- the cabin emergency lights,


R

EFF :

001-012, 014-099,  33-51-00

Page 72
Aug 01/07
 
IAC 
- the escape hatch-handle lights,
- the exit location signs,
- the exit marking signs,
- the wall-mounted exit marking signs,
- the seat/wall-mounted emergency-lights,
- the seat/wall-mounted emergency-exit location-lights.

If there is a communication failure between the emergency


power-supply units and the programming and test panel 110RH (CIDS),
the display of the programming and test panel 110RH (CIDS) shows the
message:
- EPSU COMM.

NOTE : For detailed system information refer to 23-73-00.


____

The GND SCAN mode on the programming and test panel 110RH (CIDS)
gives the operator information on the status of the emergency
power-supply units. After a failure message, the test buttons of the
individual emergency power-supply units are pushed. A red LED shows
the defective emergency power-supply units or the associated
defective loads.

**ON A/C 101-199, 901-999,

(2) Battery Capacity Test


The battery capacity test monitors:
- if the capacity of each EPSU battery is sufficient enough to supply
its emergency lights for at least 10 minutes,
- if the loss of the capacity of each battery, between two
consecutive battery capacity tests, is smaller than 0.40 Ah.
The battery capacity test requires up to three hours to be completed.
External loads are:
- the overwing emergency lights,
- the escape slide lights.

Internal loads are:


- the cabin emergency lights,
- the escape hatch-handle lights,
- the exit location signs,
- the exit marking signs.

If there is a communication failure between the emergency


power-supply units and the programming and test panel 110RH (CIDS),
the display of the programming and test panel 110RH (CIDS) shows the
message:
- EPSU COMM.



EFF :

ALL  33-51-00

Page 73
Aug 01/07
R  
IAC 
NOTE : For detailed system information refer to 23-73-00.
____

The GND SCAN mode on the programming and test panel 110RH (CIDS)
gives the operator information on the status of the emergency
power-supply units. After a failure message, the test buttons of the
individual emergency power-supply units are pushed. A red LED shows
the defective emergency power-supply units or the associated
defective loads.

**ON A/C 001-012, 014-099,

B. Emergency Lighting Batteries


The code for the battery capacity test is selected on the programming and
test panel 110RH (CIDS) and the display shows the message BATTERY
CAPACITY TEST ACTIVE. An electronic test circuit energizes when the TEST
EMER LIGHT BAT membrane switch on the programming and test panel 110RH
(CIDS) is pushed. The integral light in this membrane switch comes on.
The test circuit connects a 28 VDC positive for the emergency
power-supply units 10WL thru 13WL control line TEST and completes, at the
same time, the circuit for the BAT OK annunciator light. If all batteries
have full capacity, the test circuit is complete and the BAT OK
annunciator light comes on.

If the annunciator light does not come on, the display of the programming
and test panel 110RH (CIDS) shows the message EPSU BAT CAP. The message
EPSU BAT CAP indicates that one or more batteries of the emergency
power-supply units 10WL thru 13WL is/are defective.

NOTE : For detailed system information refer to 23-73-00.


____

The GND SCAN mode on the programming and test panel 110RH (CIDS) gives
the operator information on the status of the emergency power-supply
units. After a failure message the test buttons of the individual
emergency power-supply units are pushed. A red LED indicates the
defective emergency power-supply units or the defective batteries.

**ON A/C 101-199, 901-999,

C. Description
The EPSUs and the CIDS use a RS232 interface for the data exchange of
both BITE functions. You can start the two different BITE functions only
on the ground with a related CFDS/MCDU test menu page. Additionally the
start of the battery capacity test is code protected against inadvertent
action, because the batteries are discharged during the battery capacity
test.


R

EFF :

ALL  33-51-00

Page 74
Aug 01/07
 
IAC 
The EPSUs only accept the test start commands when the subsequent
conditions are fulfilled:
- aircraft on ground,
- all emergency lights OFF,
- 28 V DC available,
- 115 V AC available,
- control switch EMER EXIT LT 4WL in OFF position,
- pushbutton EMER on the FAP in OFF position,
- control switch NO SMOKING 190RH in OFF position.

(1) System Test


(Ref. Fig. 013, 014, 015)

When you start the system test via a CFDS/MCDU test page action the
CIDS transmit the EPSU SYS TEST data word through the related DEU
Bs to the EPSUs. When the EPSU SYS TEST data word is accepted the
EPSUs are set to the system test mode.
When the EPSUs can start the system test the status message TEST IN
PROGRESS is send to the CIDS. The system test will be completed
within approximately 60 seconds. When the system test is completed
the test results are sent to the CIDS and shown as a test result
message on the CFDS/MCDU.
When the EPSUs cannot start the system test the reason for not
starting the system test is sent to the CIDS and shown as a status
message on the CFDS/MCDU.

(2) Battery Capacity Test


(Ref. Fig. 016, 017)

You can start the battery capacity test via a CFDS/MCDU test page
action. The test start procedure is protected against accidental
operation with a code. When the EPSUs accept the code you can start
the battery capacity test and the EPSUs are set to the battery
capacity test mode. The status message EPSU BAT CAP TEST IN
PROGRESS is sent to the CFDS/MCDU.
Before the main battery capacity test starts a system test is
automatically done. If there is a system failure the battery capacity
test is stopped.

When the battery capacity test is started during high environmental


temperature conditions, e.g. Aircraft in sunlight without Air
Conditioning and the battery temperature exceeds more than 45 deg.C,
the test is delayed.
When the temperature falls to a normal day profile, the normal
battery test cycle continuous. The message on the MCDU remains for
information.



EFF :

101-199, 901-999,  33-51-00

Page 75
Aug 01/07
R  
IAC 
EPSU System Test - MCDU Start Menu
Figure 013



EFF :

101-199, 901-999,  33-51-00

Page 76
Aug 01/07
R  
IAC 
MCDU Failure Page (1/2)
Figure 014



EFF :

101-199, 901-999,  33-51-00

Page 77
Aug 01/07
R  
IAC 
MCDU Failure Page (2/2)
Figure 015



EFF :

101-199, 901-999,  33-51-00

Page 78
Aug 01/07
R  
IAC 
EPSU Battery Capacity Test - MCDU Menu Pages (1/2)
Figure 016



EFF :

101-199, 901-999,  33-51-00

Page 79
Aug 01/07
R  
IAC 
EPSU Battery Capacity Test - MCDU Menu Pages (2/2)
Figure 017



EFF :

101-199, 901-999,  33-51-00

Page 80
Aug 01/07
R  
IAC 
The maximum time for a delayed battery capacity test is 24 hours.
After a delay of more than 24 hours, the battery capacity test is
stopped.

D. Operation

(1) System Test


You can start the system test of the emergency lighting system when
you select the CIDS main menu through the CFDS SYSTEM REPORT TEST
menu page. In the CIDS main menu you have to select the SYSTEM
TEST menu page. When you push the EPSU SYS TEST line select key of
the SYSTEM TEST menu the EPSU SYS TEST menu comes on and shows
the subsequent data:
- initial conditions of starting the system test,
- < START,
- < RETURN.
When you set the START line key and the system test starts, the
message TEST IN PROGRESS XXs comes on. When the system test cannot
start, a status message shows the reason for not start the test.
When the system test is completed, a test result message comes on.

(2) Battery Capacity Test


You can start the EPSU BAT CAP TEST of the emergency lighting
system, when you select the CIDS main menu through the CFDS SYSTEM
REPORT TEST menu page. When you push the EPSU BAT CAP TEST line
key, the EPSU BAT CAP TEST 1/2 page comes on and shows the
subsequent data:
- a CAUTION message,
- initial conditions to start the test,
- < RETURN.
When you push the NEXT PAGE line key the CIDS requests the status
of all EPSUs and the message IN PROGRESS XXs comes on during the
waiting time.
After approximately XXs the EPSU BAT CAP TEST 2/2 page comes on and
shows the subsequent data:
- a CAUTION message,
- a request to enter the access code,
- START TEST,
- TEST RESULT.
As long as the correct code is not entered and there are no test
results of a previous test available there are no < prompts in
front of the START TEST and TEST RESULT messages.
When you enter the code, the < prompt comes on in front of the
START TEST message. Now you can push the START TEST line key and
the < CONFIRM START OF TEST message comes on. Push the CONFIRM
START OF TEST line key and the battery capacity test starts. The
message TEST IN PROGRESS 3HR comes on.



EFF :

101-199, 901-999,  33-51-00

Page 81
Aug 01/07
R  
IAC 
When the battery capacity test cannot start, a status message shows
the reason for not start the test.
After approximately 3 hours, when the battery capacity is completed,
a test result message or a status message comes on.



EFF :

101-199, 901-999,  33-51-00

Page 82
Aug 01/07
 
IAC 
CABIN EMERGENCY LIGHTING - DEACTIVATION/REACTIVATION
____________________________________________________

R **ON A/C 001-012, 014-099,

TASK 33-51-00-040-001

Deactivation of the EMER SYSTEM TEST of the Cabin Emergency Lighting System

1. __________________
Reason for the Job

Refer to the MMEL TASK: 33-50-07-B)


Lights
EMER LIGHT TEST on PTP
SYS TEST

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-51-00-861-057

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-51-00-865-056

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05
122VU LIGHTING/CABIN/EMER/LT 3WL V07



EFF :

ALL  33-51-00

Page 401
Nov 01/07
 
IAC 
R

Subtask 33-51-00-860-055

C. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.
R

4. Procedure
_________

Subtask 33-51-00-710-060

A. Operational test of the Cabin Emergency-Lighting System

NOTE : The time to do this test must not be more than 3 minutes, to
____
prevent discharge of the emergency lighting batteries.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. In the cockpit, on the SIGNS In the cockpit, on the SIGNS panel


panel 25VU: 25VU:
- set the EMER EXIT LT switch 4WL - the EMER EXIT LT OFF annunciator
to the ARM position. light 5WL is off.

2. On the circuit breaker panel In the cabin:


49VU:
- open the circuit breakers 1WL - all the cabin emergency lights come
and 2WL. on
- all the exit marking signs come on
- all the exit location signs come on
- all the electrical lights of the
Floor-Proximity Emergency-Escape-Path
Marking-System come on
- all the emergency-escape hatch-handle
lights come on.


R

EFF :

001-012, 014-099,  33-51-00

Page 402
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
3. On the circuit breaker panel In the cabin:
49VU:
- close the circuit breakers 1WL - all the cabin emergency lights go off
and 2WL. - all the exit marking signs go off
- all the exit location signs go off
- all the electrical lights of the
Floor-Proximity Emergency-Escape-Path
Marking-System go off
- all the emergency-escape hatch-handle
lights go off.

4. In the cockpit, on the SIGNS In the cockpit, on the SIGNS panel


panel 25VU: 25VU:
- set the EMER EXIT LT switch 4WL - the EMER EXIT LT OFF annunciator
to the OFF position. light 5WL comes on.

5. Close-up
________

Subtask 33-51-00-862-056

A. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).


R

EFF :

001-012, 014-099,  33-51-00

Page 403
Nov 01/07
 
IAC 
R **ON A/C ALL

TASK 33-51-00-040-002

Deactivation of the EMER EXIT LT OFF Annunciator Light 5WL

1. __________________
Reason for the Job

Refer to the MMEL TASK: 33-50-08


Lights
EMER EXIT LT OFF
Light on SIGNS Overhead Panel

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-51-00-861-058

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-51-00-865-057

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05
122VU LIGHTING/CABIN/EMER/LT 3WL V07



EFF :

ALL  33-51-00

Page 404
Nov 01/07
 
IAC 
INTENTIONALLY BLANK


R



 33-51-00

Page 405
Nov 01/07
 
IAC 
INTENTIONALLY BLANK


R



 33-51-00

Page 406
Nov 01/07
 
IAC 
R **ON A/C 001-012, 014-099,

Subtask 33-51-00-860-058

C. Aircraft Maintenance Configuration

(1) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the overhead panel 25VU, set the EMER EXIT LT switch 4WL to the
ARM position.

R **ON A/C 101-199, 901-999,

R Subtask 33-51-00-860-058-A

R C. Aircraft Maintenance Configuration

R (1) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
R button and its light are off.

R (2) On the overhead panel 25VU, make sure that the NO SMOKING switch
R 190RH is in the OFF position.

R (3) On the overhead panel 25VU, set the EMER EXIT LT switch 4WL to the
R ARM position.



EFF :

ALL  33-51-00

Page 407
Aug 01/07
 
IAC 
R **ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099, 901-999,

Subtask 33-51-00-710-061

A. Operational test of the Cabin Emergency Lighting System

NOTE : The time taken to do this test must not be more than 3 minutes, to
____
prevent discharge of the emergency lighting batteries.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the circuit breaker panel In the cabin:


49VU:
- open the circuit breakers 1WL - all the cabin emergency lights come
and 2WL. on
- all the exit marking signs come on
- all the exit location signs come on
- all the electrical lights of the
Floor-Proximity Emergency-Escape-Path
Marking-System come on
- all the emergency-escape hatch-handle
lights come on.

2. On the circuit breaker panel In the cabin:


49VU:
- close the circuit breakers 1WL - all the cabin emergency lights go off
and 2WL. - all the exit marking signs go off
- all the exit location signs go off
- all the electrical lights of the
Floor-Proximity Emergency-Escape-Path
Marking-System go off
- all the emergency-escape hatch-handle
lights go off.



EFF :

ALL  33-51-00

Page 408
Aug 01/07
 
IAC 
**ON A/C 101-199,

Subtask 33-51-00-710-061-A

A. Operational test of the Cabin Emergency Lighting System

NOTE : The time to do this test must not be more than 3 minutes, to
____
prevent discharge of the emergency lighting batteries.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the circuit breaker panel In the cabin:


49VU:
- open the circuit breakers 1WL - all the cabin emergency lights come
and 2WL. on
- all the exit marking signs come on
- all the exit location signs come on
- all the electrical lights of the
Floor-Proximity Emergency-Escape-Path
Marking-System come on.

2. On the circuit breaker panel In the cabin:


49VU:
- close the circuit breakers 1WL - all the cabin emergency lights go off
and 2WL. - all the exit marking signs go off
- all the exit location signs go off
- all the electrical lights of the
Floor-Proximity Emergency-Escape-Path
Marking-System go off.

**ON A/C ALL

5. Close-up
________

Subtask 33-51-00-860-060

A. Put the aircraft back to the serviceable condition.

(1) Set the EMER EXIT LT switch 4WL on the overhead panel 25VU to the OFF
position.

(2) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-51-00

Page 409
Aug 01/07
R  
IAC 
TASK 33-51-00-440-002

Reactivation of the EMER EXIT LT OFF Annunciator Light 5WL

1. __________________
Reason for the Job

Refer to the MMEL TASK: 33-50-08


Lights
EMER EXIT LT OFF
Light on SIGNS Overhead Panel

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

TSM CH 33 (for corrective action)

3. __________
Job Set-up

Subtask 33-51-00-860-059

A. There is no special job set-up for this task.

4. Procedure
_________

Subtask 33-51-00-810-051

A. Do the trouble shooting procedure of the cabin emergency lighting system


(Ref. TSM CH 33)



EFF :

ALL  33-51-00

Page 410
Aug 01/07
 
IAC 
CABIN EMERGENCY LIGHTING - ADJUSTMENT/TEST
__________________________________________

TASK 33-51-00-710-001

R Operational Test of Emergency Lights

1. __________________
Reason for the Job

Refer to the MPD TASK: 335100-01

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

23-73-00-861-001 Energize the Cabin Intercommunication Data System


(CIDS)
23-73-00-862-001 De-energize the Cabin Intercommunication Data System
(CIDS)
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
R 31-32-00-860-003 Procedure to Get Access to the SYSTEM REPORT/TEST/COM
R Page

3. __________
Job Set-up

R **ON A/C 101-199, 901-999,

R Subtask 33-51-00-860-072

R A. Aircraft Maintenance Configuration

R (1) Energize the aircraft electrical circuits


R (Ref. TASK 24-41-00-861-002).

R (2) Get access to the SYSTEM/REPORT/TEST COM Page : (Ref. TASK 31-32-00-
R 860-003).



EFF :

ALL  33-51-00

Page 501
Nov 01/07
 
IAC 
R (3) Make sure that the Cabin-Intercommunication Data System (CIDS) is
R energized (Ref. TASK 23-73-00-861-001).

R (4) On the Flight Attendant Panel (FAP) 120RH in the cabin, make sure
R that the pushbutton-switch EMER is released (position out/indicator
R light is off).

R (5) On the overhead panel 25VU in the cockpit make sure that:
R - The switch 4WL EMER EXIT LT is in the OFF position
R - The switch 190RH NO SMOKING is in the OFF position
R - The indicator 5WL EMER EXIT LT OFF is on.

R **ON A/C 001-012, 014-099,

Subtask 33-51-00-861-050

R B. Aircraft Maintenance Configuration

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

(2) Energize the Cabin Intercommunicatin Data System (CIDS) (Ref. TASK
23-73-00-861-001).

R **ON A/C ALL

Subtask 33-51-00-865-050

R C. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05
122VU LIGHTING/CABIN/EMER/LT 3WL V07


R

EFF :

ALL  33-51-00

Page 502
Nov 01/07
 
IAC 
R **ON A/C 001-012, 014-099,

Subtask 33-51-00-869-055

R D. Preparation for Test

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.

R **ON A/C ALL

4. Procedure
_________

R **ON A/C 001-012, 014-099,

Subtask 33-51-00-710-050

A. Test of the emergency lights

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the Programming and Test Panel On the PTP 110RH:


(PTP) 110RH:
- push the TEST EMER LIGHT/SYS - the SYS OK light comes on after
membrane switch for not less approx. 30 s.
than 3 s.

On the display of the PTP 110RH:


- the EMER SYSTEM ATA 33-51-38 TEST OK
status comes on.

NOTE : If the SYS OK LED comes on,


____
there are no limitations in the
operation of the emergency light


R

EFF :

ALL  33-51-00

Page 503
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
system. Any associated failure
message can be ignored for
maintenance.

On the PTP 110RH:


- the SYS OK light goes off after
approx. 60 s.

R **ON A/C 101-199, 901-999,

R Subtask 33-51-00-710-073

R B. Do this test:

R -------------------------------------------------------------------------------
R ACTION RESULT
R -------------------------------------------------------------------------------

R 1. In the cockpit on the MCDU: In the cockpit on the MCDU:

R - Push the line select key - The menu page


R CIDS 1. CIDS 1 comes into view.

R - Push the line select key - The menu page


R SYSTEM TESTS. SYSTEM TESTS comes into view.

R - Push the line select key - The menu page


R EPSU SYS TEST. EPSU SYS TEST comes into view.

R - Push the line select key - The system test starts and
R START TEST. the message TEST IN PROGRESS 60S
R shows, then
R the message TEST OK shows.

R - Push the line select key


R RETURN until the menu page
R SYSTEM REPORT/TEST comes into
R view.


R

EFF :

ALL  33-51-00

Page 504
Nov 01/07
 
IAC 
R **ON A/C ALL

5. Close-up
________

Subtask 33-51-00-862-050

A. Put the aircraft back to the serviceable condition.

(1) De-energize the CIDS (Ref. TASK 23-73-00-862-001).

(2) De-energize the aircraft electrical circuits


(Ref. TASK 24-41-00-862-002).


R

EFF :

ALL  33-51-00

Page 505
Nov 01/07
 
IAC 
TASK 33-51-00-710-003

R Check Battery Capacity

1. __________________
Reason for the Job

Refer to the MPD TASK: 335100-03

2. ______________________
Job Set-up Information

R A. Fixtures, Tools, Test and Support Equipment

R -------------------------------------------------------------------------------
R REFERENCE QTY DESIGNATION
R -------------------------------------------------------------------------------

R No specific warning notice

R B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

23-73-00-861-001 Energize the Cabin Intercommunication Data System


(CIDS)
23-73-00-862-001 De-energize the Cabin Intercommunication Data System
(CIDS)
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
R 31-32-00-860-003 Procedure to Get Access to the SYSTEM REPORT/TEST/COM
R Page


R

EFF :

ALL  33-51-00

Page 506
Nov 01/07
 
IAC 
3. __________
Job Set-up

R **ON A/C 001-012, 014-099,

Subtask 33-51-00-860-050

A. Aircraft Maintenance Configuration

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

(2) Energize the Cabin Intercommunication System (CIDS) (Ref. TASK 23-73-
00-861-001).

R **ON A/C 101-199, 901-999,

R Subtask 33-51-00-860-074

R B. Aircraft Maintenance Configuration

R (1) Energize the aircraft electrical circuits


R (Ref. TASK 24-41-00-861-002).

R (2) Get access to the SYSTEM/REPORT/TEST COM Page : (Ref. TASK 31-32-00-
R 860-003).

R (3) Make sure that the Cabin Intercommunication Data System (CIDS) is
R energized (Ref. TASK 23-73-00-861-001).

R (4) On the Flight Attendant Panel (FAP) 120RH in the cabin make sure that
R the pushbutton-switch EMER is released (position out/indicator light
R is off).

R (5) On the overhead panel 25VU in the cockpit make sure that
R - The switch 4WL EMER EXIT LT is in the OFF position
R - The switch 190RH NO SMOKING is in the OFF position
R - The indicator 5WL EMER EXIT LT OFF is on.

R (6) Put a warning notice in position at the MCDU to tell persons not to
R use the MCDU after the test start.


R

EFF :

ALL  33-51-00

Page 507
Nov 01/07
 
IAC 
R **ON A/C ALL

Subtask 33-51-00-865-052

R C. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05
122VU LIGHTING/CABIN/EMER/LT 3WL V07

4. Procedure
_________

R **ON A/C 001-012, 014-099,

Subtask 33-51-00-860-051

A. Preparation for Test

(1) Make sure that the emergency escape hatches are closed and the covers
of the control handles are installed.

(2) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(3) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(4) Reset the emergency lighting system:


- On the Forward Attendant Panel (FAP) 120RH, push the LIGHT EMER
pushbutton switch to the on position
- On the FAP 120RH, push the LIGHT EMER pushbutton switch to the off
position.


R

EFF :

ALL  33-51-00

Page 508
Nov 01/07
 
IAC 
Subtask 33-51-00-710-052

B. Check battery capacity

NOTE : Make sure that the aircraft power supply stays on during this
____
test.

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the Programming and Test Panel On the PTP 110RH:


(PTP) 110RH:
- push the DSPL ON membrane - the CIDS menu comes on.
switch.

- push the SYST TEST line select - the SYST TEST menu comes on.
key.

- push CONT until the EMER LIGHT


BATTERY display comes on.

- push the EMER LIGHT BATTERY - the ENTER ACCESS CODE page comes on.
line select key.

- put in this users code: 3351.

- push the ENTER line select key. - the EMER BATTERY TEST page and the
PUSH BAT KEY display comes on.

- push the TEST EMER-LIGHT BAT - the integral light of the BAT
membrane switch. membrane switch comes on.
- on the PTP display a clock comes on
and shows the time taken for the
test.

On the PTP 110RH after approx. 2 h:


- the EMER BATTERY ATA 33-51-38 TEST OK
status comes on.
- the BAT OK light comes on.

2. On the PTP 110RH: On the PTP 110RH:


- push the RET line select key. - the EMER LIGHT BATTERY display comes
on.


R

EFF :

001-012, 014-099,  33-51-00

Page 509
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
NOTE : If you select another mode/menu
____
on the PTP when the battery
capacity check is running. And
you then push the RET line
select key the PTP will not show
the EMER BATTERY TEST page. But
it will show the first page of
the mode/menu you selected
before.

- push the EMER LIGHT BATTERY - the EMER BATTERY TEST page comes on.
line select key.

- push the BAT TEST RESET line - the SYST TEST menu comes on.
select key. - the BAT OK light goes off.
- the integral light of the BAT
membrane switch goes off.

- push the DSPL ON membrane - the CIDS menu comes on.


switch.

R **ON A/C 101-199, 901-999,

R Subtask 33-51-00-710-075

R C. Do this test:

R NOTE : For the battery capacity test, a maximum of 3 hours can be


____
R necessary. The aircraft power supply must stay on during the full
R test. The batteries are discharged and charged during the test.

R NOTE : After the start of the test, the MCDU must stay in the menu page
____
R CIDS/EPSU BAT CAP TEST during the full test to get the test
R result, because the test result cannot get through the menu page
R CIDS/EPSU BAT CAP TEST RESULT (CIDS fault).



EFF :

ALL  33-51-00

Page 510
Nov 01/07
 
IAC 
R -------------------------------------------------------------------------------
R ACTION RESULT
R -------------------------------------------------------------------------------

R 1. In the cockpit on the MCDU: In the cockpit on the MCDU:

R - Push the line select key - The menu page


R CIDS 1. CIDS 1 comes into view.

R - Push the line select key - The menu page


R EPSU BAT CAP TEST. EPSU BAT CAP TEST 1/2 comes into
R view.

R - Push the down-arrow function - The message IN PROGRESS 60S comes on,
R key. then the menu page
R EPSU BAT CAP TEST 2/2 shows.

R - With the alphanumeric keys - In the scratchpad the


R enter the four digits 3351. user-access-code 3351 appears.
R
R - The < prompt in front of
R the message START TEST comes into
R view.

R - Push the line select key - The message CONFIRM START OF TEST
R START TEST. shows.

R - Push the line select key - The message TEST IN PROGRESS 3HR
R CONFIRM START OF TEST. shows, then the message TEST OK
R shows.

R NOTE : If the battery capacity


____
R test is started during
R high environmental
R temperature conditions,
R e.g. > 45 deg.C, and the
R status message BAT
R OVERTEMP - END OF TEST
R DELAYED is shown on MCDU,
R the test will be delayed.
R If the temperature falls
R to a normal day profile,
R the test will continue.
R The message on the MCDU
R remains for information.

R - Push the line select key


R

EFF :

101-199, 901-999,  33-51-00

Page 511
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
R RETURN, until the menu page
R MCDU MENU comes into view.

R **ON A/C ALL

5. Close-up
________

Subtask 33-51-00-862-052

A. Put the aircraft back to the serviceable condition.

(1) De-energize the CIDS (Ref. TASK 23-73-00-862-001).

(2) De-energize the aircraft electrical circuits


(Ref. TASK 24-41-00-862-002).


R

EFF :

ALL  33-51-00

Page 512
Nov 01/07
 
IAC 
TASK 33-51-00-710-003- 01

Remove Batteries for Capacity Check

1. __________________
Reason for the Job

Refer to the MPD TASK: 335100-03

R NOTE : This task is alternative to 33-51-00-710-003.


____

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-51-38-000-002 Removal of the Battery of the Emergency Power-Supply


Unit
33-51-38-400-002 Installation of the Battery of the Emergency
Power-Supply Unit

3. __________
Job Set-up

Subtask 33-51-00-860-057

A. There is no special job set-up for this task.

4. Procedure
_________

R **ON A/C 001-012, 014-099,

Subtask 33-51-00-920-050

A. Replacement of the Battery Pack

(1) Remove the batteries of all Emergency Power Supply Units (EPSU)
(Ref. TASK 33-51-38-000-002).

(2) Install fully charged batteries to all EPSU (Ref. TASK 33-51-38-400-
002).



EFF :

ALL  33-51-00

Page 513
May 01/08
 
IAC 
R **ON A/C ALL

TASK 33-51-00-710-004

Check manual Operation from both Control Panels and check all Cabin Lights and
Signs illuminated by Batteries

1. __________________
Reason for the Job

Refer to the MPD TASK: 335100-05

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-51-00-861-053

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-51-00-865-053

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05
122VU LIGHTING/CABIN/EMER/LT 3WL V07



EFF :

ALL  33-51-00

Page 514
May 01/08
 
IAC 
4. Procedure
_________

**ON A/C 001-012, 014-099,

Subtask 33-51-00-860-052

A. Preparation for Test

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.

Subtask 33-51-00-710-053

B. Test of both Control Panels and the Emergency Lighting System

R (1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. In the cockpit, on the SIGNS In the cockpit, on the SIGNS panel


panel 25VU: 25VU:
R - Set the EMER EXIT LT switch 4WL - The EMER EXIT LT OFF annunciator 5WL
R to the ON position. goes off.

In the cabin:
R - The signs and the lights of the
R emergency lighting system come on.

2. On the SIGNS panel 25VU: On the SIGNS panel 25VU:


R - Set the EMER EXIT LT switch 4WL - The EMER EXIT LT OFF annunciator 5WL
R to the OFF position. comes on.

In the cabin:
R - The signs and the lights of the
R emergency lighting system go off.

3. On the FAP 120RH: On the FAP 120RH:



EFF :

ALL  33-51-00

Page 515
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
R - Push the LIGHT EMER pushbutton - The red light of the LIGHT EMER
R switch. pushbutton switch comes on.

In the cabin:
R - The signs and the lights of the
R emergency lighting system come on.

4. On the FAP 120RH: On the FAP 120RH:


R - Push the LIGHT EMER pushbutton - The red light of the LIGHT EMER
R switch. pushbutton switch goes off.

In the cabin:
R - The signs and the lights of the
R emergency lighting system go off.

**ON A/C 101-199, 901-999,

Subtask 33-51-00-860-052-A

A. Preparation for Test

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
pushbutton switch and its integral light are off.


R

EFF :

ALL  33-51-00

Page 516
Nov 01/07
 
IAC 
Subtask 33-51-00-710-053-A

B. Test of both Control Panels and the Emergency Lighting System

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. In the cockpit, on the SIGNS In the cockpit, on the SIGNS panel


panel 25VU: 25VU:
- set the EMER EXIT LT switch 4WL - the EMER EXIT LT OFF annunciator 5WL
to the ON position. goes off.

In the cabin:
- the signs and lights of the emergency
lighting system come on.

2. On the SIGNS panel 25VU: On the SIGNS panel 25VU:


- set the EMER EXIT LT switch 4WL - the EMER EXIT LT OFF annunciator 5WL
to the OFF position. comes on.

In the cabin:
- the signs and lights of the emergency
lighting system go off.

3. On the FAP 120RH: On the FAP 120RH:


- push the EMER pushbutton - the integral light of the EMER
switch. pushbutton switch comes on.

In the cabin:
- the signs and lights of the emergency
lighting system come on.

4. On the FAP 120RH: On the FAP 120RH:


- push the EMER pushbutton - the integral light of the EMER
switch. pushbutton switch goes off.

In the cabin:
- the signs and lights of the emergency
lighting system go off.



EFF :

101-199, 901-999,  33-51-00

Page 517
Nov 01/07
R  
IAC 
**ON A/C ALL

Subtask 33-51-00-710-057

C. Test of both Control Panels and the Emergency Lighting System

R NOTE : The time to do this test must not be more than 1 minute. This is
____
R to prevent the discharge of the emergency lighting batteries.

(1) Do this test with the circuit breakers 1WL and 2WL on the circuit
breaker panel 49VU.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. In the cockpit, on the SIGNS In the cockpit, on the SIGNS panel


panel 25VU: 25VU:
R - Set the EMER EXIT LT switch 4WL - The EMER EXIT LT OFF annunciator 5WL
R to the ARM position. goes off.

2. On the circuit breaker panel In the cabin:


49VU:
R - Open the circuit breakers 1WL - The emergency lights and signs come
R and 2WL. on.

R - Close the circuit breakers 1WL - The emergency lights and signs go
R and 2WL. off.

3. On the SIGNS panel 25VU: On the SIGNS panel 25VU:


R - Set the EMER EXIT LT switch 4WL - The EMER EXIT LT OFF annunciator 5WL
R to the OFF position. comes on.

5. Close-up
________

Subtask 33-51-00-862-053

A. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-51-00

Page 518
Nov 01/07
 
IAC 
TASK 33-51-00-710-006

Operational Test of Emergency Lights not with CIDS

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific stepladder 1.5 m (4 ft. 11 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
FOR FIN 10WL
25-23-42-000-001 Removal of the Ceiling Panels - Forward Utility Area
25-23-42-400-001 Installation of the Ceiling Panels - Forward Utility
Area
FOR FIN 13WL
25-23-45-000-003 Removal of the Door Frame Linings at the Left AFT
Passenger/Crew Door
25-23-45-400-008 Installation of the Door Frame Linings at the Left
AFT Passenger/Crew Door
35-21-41-000-001 Removal of the Emergency Oxygen Containers
35-21-41-400-001 Installation of the Emergency Oxygen Containers
FOR FIN 11WL
25-23-41-000-001 Removal of the Ceiling Panels
25-23-41-400-001 Installation of the Ceiling Panels
25-23-44-000-001 Removal of the Lower Sidewall-Panels (Dado Panels)
25-23-44-400-001 Installation of the Lower Sidewall-Panels (Dado
Panels)
FOR FIN 12WL
25-23-41-000-001 Removal of the Ceiling Panels



EFF :

ALL  33-51-00

Page 519
Nov 01/07
R  
IAC 
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

25-23-41-400-001 Installation of the Ceiling Panels


25-23-44-000-001 Removal of the Lower Sidewall-Panels (Dado Panels)
25-23-44-400-001 Installation of the Lower Sidewall-Panels (Dado
Panels)
FOR FIN 14WL
25-23-41-000-001 Removal of the Ceiling Panels
25-23-41-400-001 Installation of the Ceiling Panels
FOR FIN 15WL
25-23-41-000-001 Removal of the Ceiling Panels
25-23-41-400-001 Installation of the Ceiling Panels

3. __________
Job Set-up

Subtask 33-51-00-861-056

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

**ON A/C 001-012, 014-099,

Subtask 33-51-00-010-053

B. Get Access

(1) Put the stepladder in position:


FOR 10WL
at the left FWD passenger/crew door,
FOR 13WL
at the left AFT passenger/crew doors.

(2) Remove the ceiling panel to get access to the emergency power-supply
unit:
FOR 10WL
remove 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-42-
000-001).

(3) Remove the lower sidewall panel to get access to the emergency
power-supply unit:
FOR 11WL
remove 241KW at the left emergency exits (Ref. TASK 25-23-44-000-
001),
FOR 12WL



EFF :

ALL  33-51-00

Page 520
Nov 01/07
R  
IAC 
remove 242KW at the right emergency exits (Ref. TASK 25-23-44-000-
001).

(4) Remove the door frame lining to get access to the emergency
power-supply unit:
FOR 13WL
remove 261KW at the left AFT passenger/crew door (Ref. TASK 25-23-45-
000-003).

**ON A/C 101-199,

Subtask 33-51-00-010-053-B

B. Get Access

(1) Put the stepladder in position:


FOR 10WL
at the left FWD passenger/crew door,
FOR 11WL
between the rear emergency exit doors,
FOR 12WL
between the rear emergency exit doors,
FOR 13WL
between the AFT passenger/crew doors,
FOR 14WL
between the forward emergency exit doors,
FOR 15WL
between the forward emergency exit doors.

(2) Remove the ceiling panel to get access to the emergency power-supply
unit:
FOR 10WL
remove 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-42-
000-001),
FOR 11WL
remove 251KC between the rear emergency exit doors (Ref. TASK 25-23-
41-000-001),
FOR 12WL
remove 251KC between the rear emergency exit doors (Ref. TASK 25-23-
41-000-001),
FOR 14WL
remove 231JC between the forward emergency exit doors (Ref. TASK 25-
23-41-000-001),
FOR 15WL
remove 231JC between the forward emergency exit doors (Ref. TASK 25-
23-41-000-001),



EFF :

001-012, 014-099, 101-199,  33-51-00

Page 521
Nov 01/07
R  
IAC 
(3) Lower one side of the emergency oxygen container to get access to the
emergency power-supply unit:
FOR 13WL
disengage and lower one side of the emergency oxygen container 33WR
between the AFT passenger/crew doors (Ref. TASK 35-21-41-000-001).

NOTE : Do not disconnect the electrical connector of the emergency


____
oxygen container.

**ON A/C 901-999,

Subtask 33-51-00-010-053-A

B. Get Access

(1) Put the stepladder in position:


FOR 10WL
at the left FWD passenger/crew door,
FOR 13WL
between the AFT passenger/crew doors,

(2) Remove the ceiling panel to get access to the emergency power-supply
unit:
FOR 10WL
remove 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-42-
000-001).

(3) Remove the lower sidewall panel to get access to the emergency
power-supply unit:
FOR 11WL
remove 241KW at the left emergency exit(s) (Ref. TASK 25-23-44-000-
001),
FOR 12WL
remove 242KW at the right emergency exit(s) (Ref. TASK 25-23-44-000-
001).

(4) Lower one side of the emergency oxygen container to get access to the
emergency power-supply unit:
FOR 13WL
disengage and lower one side of the emergency oxygen container 33WR
between the AFT passenger/crew doors (Ref. TASK 35-21-41-000-001).

NOTE : Do not disconnect the electrical connector of the emergency


____
oxygen container.


R

EFF :

101-199, 901-999,  33-51-00

Page 522
Nov 01/07
 
IAC 
**ON A/C ALL

Subtask 33-51-00-865-055

C. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05
122VU LIGHTING/CABIN/EMER/LT 3WL V07

**ON A/C 001-012, 014-099,

Subtask 33-51-00-869-057

D. Preparation for Test

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.

**ON A/C 101-199, 901-999,

Subtask 33-51-00-869-057-A

D. Preparation for Test

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
pushbutton switch and its integral light are off.



EFF :

ALL  33-51-00

Page 523
Nov 01/07
R  
IAC 
**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

Subtask 33-51-00-710-059

A. Test of the Emergency Lights

NOTE : The test is the same for all emergency power-supply units.
____

(1) Do this test when the SYSTEM TEST through the PTP is not available.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the emergency power-supply On the emergency power-supply unit:


unit:
- push the TEST pushbutton for - the green LED
approx. 2 s. - BATTERY OK,
- INTERNAL LOADS OK,
- EXTERNAL LOADS OK
come on for approx. 1 min if all test
loops are completed without
malfunction.



EFF :

ALL  33-51-00

Page 524
Nov 01/07
R  
IAC 
**ON A/C 101-199, 901-999,

Subtask 33-51-00-710-059-A

A. Test of the Emergency Lights

NOTE : The test is the same for all emergency power-supply units.
____

(1) Do this test when the SYSTEM TEST through the MCDU is not available.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the emergency power-supply On the emergency power-supply unit:


unit:
- push the TEST membrane switch - the green SYSTEM OK LED comes on for
for approximately 2 s. approximately 30 s if all test loops
are completed without malfunction.

**ON A/C ALL

5. Close-up
________

**ON A/C 001-012, 014-099,

Subtask 33-51-00-410-053

A. Close Access

(1) Install the ceiling panel:


FOR 10WL
install 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-
42-400-001).

(2) Install the lower sidewall panel:


FOR 11WL
install 241KW at the left emergency exits (Ref. TASK 25-23-44-400-
001),
FOR 12WL
install 242KW at the right emergency exits (Ref. TASK 25-23-44-400-
001).



EFF :

ALL  33-51-00

Page 525
Nov 01/07
R  
IAC 
(3) Install the door frame lining:
FOR 13WL
install 261KW at the left AFT passenger/crew door (Ref. TASK 25-23-
45-400-008).

(4) Remove the stepladder(s).

**ON A/C 101-199,

Subtask 33-51-00-410-053-B

A. Close Access

(1) Install the ceiling panel:


FOR 10WL
install 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-
42-400-001),
FOR 11WL
install 251KC between the rear emergency exit doors (Ref. TASK 25-23-
41-400-001),
FOR 12WL
install 251KC between the rear emergency exit doors (Ref. TASK 25-23-
41-400-001),
FOR 14WL
install 231JC between the forward emergency exit doors (Ref. TASK 25-
23-41-400-001),
FOR 15WL
install 231JC between the forward emergency exit doors (Ref. TASK 25-
23-41-400-001),

(2) Engage the emergency oxygen container:


FOR 13WL
lift and engage the emergency oxygen container 33WR between the AFT
passenger/crew doors (Ref. TASK 35-21-41-400-001).

(3) Remove the stepladder(s).


R

EFF :

001-012, 014-099, 101-199,  33-51-00

Page 526
Nov 01/07
 
IAC 
**ON A/C 901-999,

Subtask 33-51-00-410-053-A

A. Close Access

(1) Install the ceiling panel:


FOR 10WL
install 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-
42-400-001).

(2) Install the lower sidewall panel:


FOR 11WL
install 241KW at the left emergency exit(s) (Ref. TASK 25-23-44-400-
001),
FOR 12WL
install 242KW at the right emergency exit(s) (Ref. TASK 25-23-44-400-
001).

(3) Engage the emergency oxygen container:


FOR 13WL
lift and engage the emergency oxygen container 33WR between the AFT
passenger/crew doors (Ref. TASK 35-21-41-400-001).

(4) Remove the stepladder(s).

**ON A/C ALL

Subtask 33-51-00-862-055

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-51-00

Page 527
Nov 01/07
R  
IAC 
TASK 33-51-00-710-007

Operational Test of the Emergency Lighting in the Cabin by LIGHT EMER


Pushbutton Switch

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-51-00-861-059

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-51-00-865-058

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05
122VU LIGHTING/CABIN/EMER/LT 3WL V07



EFF :

ALL  33-51-00

Page 528
Nov 01/07
R  
IAC 
**ON A/C 001-012, 014-099,

Subtask 33-51-00-860-061

C. Preparation for Test

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.

**ON A/C 101-199, 901-999,

Subtask 33-51-00-860-061-A

C. Preparation for Test

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
pushbutton switch is off and its internal light is dim.



EFF :

ALL  33-51-00

Page 529
Nov 01/07
R  
IAC 
**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

Subtask 33-51-00-710-062

A. Test of the Emergency Lighting in the Cabin with the LIGHT EMER
Pushbutton Switch

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. In the cabin, on the FAP 120RH: In the cabin, on the FAP 120RH:
- push the LIGHT EMER pushbutton - the red integral light of the LIGHT
switch. EMER pushbutton switch comes on.

In the cabin:
- the emergency lighting comes on.

2. In the cabin, on the FAP 120RH: In the cabin, on the FAP 120RH:
- push the LIGHT EMER pushbutton - the red integral light of the LIGHT
switch. EMER pushbutton switch goes off.

In the cabin:
- the emergency lighting goes off.



EFF :

ALL  33-51-00

Page 530
Nov 01/07
R  
IAC 
**ON A/C 101-199, 901-999,

Subtask 33-51-00-710-062-A

A. Test of the Emergency Lighting in the Cabin with the EMER Pushbutton
Switch

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. In the cabin, on the FAP 120RH: In the cabin, on the FAP 120RH:
- push the EMER pushbutton - the integral light of the EMER
switch. pushbutton switch comes on.

In the cabin:
- the emergency lighting comes on.

2. In the cabin, on the FAP 120RH: In the cabin, on the FAP 120RH:
- push the EMER pushbutton - the red internal light of the EMER
switch. pushbutton switch becomes dim.

In the cabin:
- the emergency lighting goes off.

**ON A/C ALL

5. Close-up
________

Subtask 33-51-00-862-058

A. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-51-00

Page 531
Nov 01/07
R  
IAC 
TASK 33-51-00-710-008

Operational Test of the Emergency Lighting in the Cabin by EMER EXIT LT
Switch

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-51-00-861-060

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-51-00-865-059

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05
122VU LIGHTING/CABIN/EMER/LT 3WL V07


R

EFF :

ALL  33-51-00

Page 532
Nov 01/07
 
IAC 
**ON A/C 001-012, 014-099,

Subtask 33-51-00-860-062

C. Preparation for Test

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.

**ON A/C 101-199, 901-999,

Subtask 33-51-00-860-062-A

C. Preparation for Test

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
pushbutton switch and its integral light are off.


R

EFF :

ALL  33-51-00

Page 533
Nov 01/07
 
IAC 
**ON A/C ALL

4. Procedure
_________

Subtask 33-51-00-710-063

A. Test of the Emergency Lighting in the Cabin with the EMER EXIT LT Switch

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. In the cockpit, on the overhead In the cockpit, on the overhead panel


panel 25VU: 25VU:
- set the EMER EXIT LT switch 4WL - the EMER EXIT LT OFF annunciator
to the ON position. light 5WL goes off.

In the cabin:
- the emergency lighting comes on.

2. In the cockpit, on the overhead In the cockpit, on the overhead panel


panel 25VU: 25VU:
- set the EMER EXIT LT switch 4WL - the EMER EXIT LT OFF annunciator
to the OFF position. light 5WL comes on.

In the cabin:
- the emergency lighting goes off.

5. Close-up
________

Subtask 33-51-00-862-059

A. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-51-00

Page 534
Nov 01/07
R  
IAC 
TASK 33-51-00-720-001

Check Door Switch Power supplied by Emer. Light System and check Door Switch
Operation to activate the Exterior Lights

1. __________________
Reason for the Job

Refer to the MPD TASK: 335100-06

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific digital multimeter


No specific warning notice
No specific stepladder 1.5 m (4 ft. 11 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
31-60-00-860-001 EIS Start Procedure
31-60-00-860-002 EIS Stop Procedure
R 33-51-00-710-001 Operational Test of Emergency Lights
R
52-21-00-720-001 Functional Test of the Automatic and the Manual Slide
Release Signal
FOR FIN 10WL
25-23-42-000-001 Removal of the Ceiling Panels - Forward Utility Area
25-23-42-400-001 Installation of the Ceiling Panels - Forward Utility
Area
FOR FIN 13WL
25-23-42-000-002 Removal of the Ceiling Panels - Aft Utility Area
25-23-42-400-002 Installation of the Ceiling Panels - Aft Utility Area
25-23-45-000-003 Removal of the Door Frame Linings at the Left AFT
Passenger/Crew Door



EFF :

ALL  33-51-00

Page 535
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

25-23-45-400-008 Installation of the Door Frame Linings at the Left


AFT Passenger/Crew Door
FOR FIN 11WL
25-23-41-000-001 Removal of the Ceiling Panels
25-23-41-400-001 Installation of the Ceiling Panels
FOR FIN 12WL
25-23-41-000-001 Removal of the Ceiling Panels
25-23-41-400-001 Installation of the Ceiling Panels
FOR FIN 14WL
25-23-41-000-001 Removal of the Ceiling Panels
25-23-41-400-001 Installation of the Ceiling Panels
FOR FIN 15WL
25-23-41-000-001 Removal of the Ceiling Panels
25-23-41-400-001 Installation of the Ceiling Panels

3. __________
Job Set-up

Subtask 33-51-00-861-054

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-51-00-865-054

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05

**ON A/C 001-012, 014-099,

121VU COM NAV/CIDS/PROG AND TST PNL 161RH M06

**ON A/C ALL

121VU EIS/SLIDES/ARM AND WARN/FLT 15WN P11


121VU EIS/SLIDES/ARM AND WARN/GND 13WN P10
121VU EIS/SDAC1 AND 2/DOOR/DET/PAX 48WV P05
122VU LIGHTING/CABIN/EMER/LT 3WL V07



EFF :

ALL  33-51-00

Page 536
Nov 01/07
R  
IAC 
**ON A/C 001-012, 014-099,

Subtask 33-51-00-010-050

C. Get Access

(1) Put the stepladder in position:


FOR 10WL
at the left FWD passenger/crew door,
FOR 13WL
at the left AFT passenger/crew doors.

(2) Remove the ceiling panel to get access to the emergency power-supply
unit:
FOR 10WL
remove 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-42-
000-001),

(3) Remove the door frame lining to get access to the emergency
power-supply unit:
FOR 13WL
remove 261KW at the left AFT passenger/crew door (Ref. TASK 25-23-45-
000-003).

**ON A/C 101-199,

Subtask 33-51-00-010-050-B

C. Get Access

(1) Put the stepladder in position:


FOR 10WL
at the left FWD passenger/crew door,
FOR 11WL
between the rear emergency exit doors,
FOR 12WL
between the rear emergency exit doors,
FOR 13WL
at the left AFT passenger/crew door,
FOR 14WL
between the forward emergency exit doors,
FOR 15WL
between the forward emergency exit doors.


R

EFF :

001-012, 014-099, 101-199,  33-51-00

Page 537
Nov 01/07
 
IAC 
(2) Remove the ceiling panel to get access to the emergency power-supply
unit:
FOR 10WL
remove 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-42-
000-001),
FOR 11WL
remove 251KC between the rear emergency exit doors (Ref. TASK 25-23-
41-000-001),
FOR 12WL
remove 251KC between the rear emergency exit doors (Ref. TASK 25-23-
41-000-001),
FOR 14WL
remove 231JC between the forward emergency exit doors (Ref. TASK 25-
23-41-000-001),
FOR 15WL
remove 231JC between the forward emergency exit doors (Ref. TASK 25-
23-41-000-001),
FOR 13WL
remove 261CC at the left AFT passenger/crew door (Ref. TASK 25-23-42-
000-002).

**ON A/C 901-999,

Subtask 33-51-00-010-050-A

C. Get Access

(1) Put the stepladder in position:


FOR 10WL
at the left FWD passenger/crew door,
FOR 13WL
at the left AFT passenger/crew door.

(2) Remove the ceiling panel to get access to the emergency power-supply
unit:
FOR 10WL
remove 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-42-
000-001),
FOR 13WL
remove 261CC at the left AFT passenger/crew door (Ref. TASK 25-23-42-
000-002).


R

EFF :

101-199, 901-999,  33-51-00

Page 538
Nov 01/07
 
IAC 
**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

Subtask 33-51-00-860-053

A. Preparation for Test

(1) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
(Ref. TASK 31-60-00-860-001).

(2) Close all passenger/crew doors and emergency exits.

(3) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(4) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(5) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.

(6) Put the warning notice in position internally on the passenger/crew


doors and the emergency exits to tell persons not to open the doors
and the emergency exits.

(7) Use the digital multimeter (DGTL multimeter) for this test.

**ON A/C 101-199, 901-999,

Subtask 33-51-00-860-053-A

A. Preparation for Test

(1) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
(Ref. TASK 31-60-00-860-001).

(2) Close all passenger/crew doors and emergency exits.

(3) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.



EFF :

ALL  33-51-00

Page 539
Nov 01/07
R  
IAC 
(4) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(5) On the FLight Attendant Panel (FAP) 120RH, make sure that the EMER
pushbutton switch and its integral light are off.

(6) Put the warning notice in position internally on the passenger/crew


doors and the emergency exits to tell persons not to open the doors
and the emergency exits.

(7) Use the digital multimeter (DGTL multimeter) for this test.

**ON A/C 001-012, 014-099, 901-999,

Subtask 33-51-00-710-054

B. Test of the door-switch power supplies with the EMER-EXIT LT switch 4WL

WARNING : BEFORE YOU START WORK ON THE DOOR, MAKE SURE THAT:
_______
- THE EMERGENCY CONTROL HANDLE IS IN THE DISARMED POSITION WITH
THE SAFETY PIN INSTALLED.
- THE PERCUSSION LEVER OF THE DOOR-DAMPER AND
EMERGENCY-OPERATION CYLINDER IS IN THE DISARMED POSITION WITH
THE SAFETY PIN INSTALLED.

WARNING : DO NOT OPEN THE PASSENGER/CREW DOORS.


_______

NOTE : The time taken to do this test should not exceed 3 minutes to
____
prevent discharge of the emergency lighting batteries.

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On all passenger/crew doors:


- remove the safety pins.
- put the escape-slide control
handle to the ARM position.

2. In the cockpit, on the ECAM In the cockpit, on the lower ECAM


control panel: display unit:
- push the DOOR membrane switch. - the DOOR/OXY status page comes on.



EFF :

ALL  33-51-00

Page 540
Nov 01/07
R  
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- the DOOR symbols are shown in green
and the SLIDE messages are shown in
white.

3. In the cockpit on the secondary


circuit breaker panel 121VU:

- open the circuit breakers 13WN - the DOOR symbols become amber and the
and 15WN. SLIDE messages go out of view.

4. In the cockpit on the SIGNS panel


25VU:

- set the EMER EXIT LT switch 4WL - the DOORS symbols become green and
to the ON position. the SLIDE messages come into view.

- set the EMER EXIT LT switch 4WL - the DOOR symbols become amber and the
to the OFF position. SLIDE messsages go out of view.

5. In the cockpit, on the secondary


circuit breaker panel 121VU:
- close the circuit breakers 13WN
and 15WN.

On all passenger/crew doors:


- put the escape-slide control
handle to the DISARMED
position.
- install the safety pin.

**ON A/C 101-199,

Subtask 33-51-00-710-054-A

B. Test of the door-switch power supplies with the EMER-EXIT LT switch 4WL

WARNING : BEFORE YOU START WORK ON THE DOOR, MAKE SURE THAT:
_______
- THE EMERGENCY CONTROL HANDLE IS IN THE DISARMED POSITION WITH
THE SAFETY PIN INSTALLED.
- THE PERCUSSION LEVER OF THE DOOR-DAMPER AND
EMERGENCY-OPERATION CYLINDER IS IN THE DISARMED POSITION WITH
THE SAFETY PIN INSTALLED.



EFF :

ALL  33-51-00

Page 541
Nov 01/07
R  
IAC 
WARNING : DO NOT OPEN THE PASSENGER/CREW DOORS.
_______

NOTE : The time taken to do this test should not exceed 3 minutes to
____
prevent discharge of the emergency lighting batteries.

(1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On all passenger/crew doors and


emergency exit doors:
- remove the safety pins.
- put the escape-slide control
handle to the ARMED position.

2. In the cockpit, on the ECAM In the cockpit, on the lower ECAM


control panel: display unit:
- push the DOOR membrane switch. - the DOOR/OXY status page comes on.
- the DOOR symbols are shown in green
and the SLIDE messages are shown in
white.

3. In the cockpit on the secondary


circuit breaker panel 121VU:

- open the circuit breakers 13WN - the DOOR symbols become amber and the
and 15WN. SLIDE messages go out of view.

4. In the cockpit on the SIGNS panel


25VU:

- set the EMER EXIT LT switch 4WL - the DOORS symbols become green and
to the ON position. the SLIDE messages come into view.

- set the EMER EXIT LT switch 4WL - the DOOR symbols become amber and the
to the OFF position. SLIDE messsages go out of view.

5. In the cockpit, on the secondary


circuit breaker panel 121VU:
- close the circuit breakers 13WN
and 15WN.

On all passenger/crew doors and


emergency exit doors:


R

EFF :

101-199,  33-51-00

Page 542
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- put the escape-slide control
handle to the DISARMED
position.
- install the safety pin.

**ON A/C ALL

Subtask 33-51-00-720-050

C. Test of the FWD and AFT passenger/crew door switches of the


emergency-exit escape-slide lighting.

WARNING : BEFORE YOU START WORK ON THE DOOR, MAKE SURE THAT:
_______
- THE EMERGENCY CONTROL HANDLE IS IN THE DISARMED POSITION WITH
THE SAFETY PIN INSTALLED.
- THE PERCUSSION LEVER OF THE DOOR-DAMPER AND
EMERGENCY-OPERATION CYLINDER IS IN THE DISARMED POSITION WITH
THE SAFETY PIN INSTALLED.

WARNING : DO NOT OPEN THE PASSENGER/CREW DOORS.


_______

NOTE : Make sure that the EMER EXIT LT switch 4WL on the SIGNS panel 25VU
____
is in the OFF position. This test is for the FWD RH/LH
passenger/crew doors. For the AFT RH/LH passenger/crew doors use
the information in the brackets.

(1) Do this Test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the aircraft:
- make sure that the related
passenger/crew door is closed.

2. In the cockpit, on the overhead


circuit breaker panel 49VU:
- open the circuit breakers,
LIGHTING EMER LT CABIN, 1WL and
2WL.


R

EFF :

ALL  33-51-00

Page 543
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
3. In the cockpit, on the secondary
circuit breaker panel 122VU:
- open the circuit breaker, CABIN
EMER LT, 3WL.

4. In Zone 221 (261) on the


emergency power-supply unit 10WL
(13WL):
- remove the electrical connector
10WL-A (13WL-A).

5. On the DGTL multimeter:


- connect the positive test lead
of the DGTL multimeter to pin C
of the connector 10WL-A
(13WL-A),
- connect the negative test lead
of the DGTL multimeter to pin m
of the connector 10WL-A
(13WL-A).
- set the DGTL multimeter to the
kilo ohm range.

NOTE : The closed circuit is in the kilo ohm range because the door switches
____
are electronic types.

6. On the FWD (AFT) left In Zone 221 (261) on the DGTL


passenger/crew door: multimeter:
- remove the safety pin from the
control handle of the escape
slide.

- set the slide control handle to - the DGTL multimeter shows a closed
the ARMED position. circuit.

- set the slide control handle to - the DGTL multimeter shows an open
the DISARMED position. circuit.

- install the safety pin in the


control handle of the escape
slide.

7. On the DGTL multimeter:


R

EFF :

ALL  33-51-00

Page 544
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- connect the positive test lead
of the DGTL multimeter to pin D
of the connector 10WL-A
(13WL-A),
- connect the negative test lead
of the DGTL multimeter to pin m
of the connector 10WL-A
(13WL-A).

8. On the FWD (AFT) left


passenger/crew door:

- lift the door handle - the DGTL multimeter shows an open


approximately 10.0 mm (0.3937 circuit.
in.), but do not open the
passenger/crew door.

- lock the door handle. - the DGTL multimeter shows a closed


circuit.

9. On the DGTL multimeter:


- connect the positive test lead
of the DGTL multimeter to pin S
of the connector 10WL-A
(13WL-A),
- connect the negative test lead
of the DGTL multimeter to pin m
of the connector 10WL-A
(13WL-A).

10. On the FWD (AFT) right


passenger/crew door:
- remove the safety pin from the
control handle of the escape
slide.

- set the slide control handle - the DGTL multimeter shows a closed
to the ARMED position. circuit.

- set the slide control handle - the DGTL multimeter shows an open
to the DISARMED position. circuit.


R

EFF :

ALL  33-51-00

Page 545
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- install the safety pin in the
control handle of the escape
slide.

11. On the DGTL multimeter:


- connect the positive test lead
of the DGTL multimeter to pin
k of the connector 10WL-A
(13WL-A),
- connect the negative test lead
of the DGTL multimeter to pin
m of the connector 10WL-A
(13WL-A).

12. On the FWD (AFT) right


passenger/crew door:

- lift the door handle - the DGTL multimeter shows an open


approximately 10.0 mm (0.3937 circuit.
in.), but do not open the
passenger/crew door.

- lock the door handle. - the DGTL multimeter shows a closed


circuit.

13. On the DGTL multimeter:


- disconnect the testleads and
remove the DGTL multimeter.

14. On the emergency power-supply


unit 10WL (13WL):
- connect the electrical
connector 10WL-A (13WL-A).

15. In the cockpit, on the overhead


circuit breaker panel 49VU:
- close the circuit breakers,
LIGHTING EMER LT CABIN, 1WL
and 2WL.

16. In the cockpit, on the secondary


circuit breaker panel 122VU:
- close the circuit breaker,
CABIN EMER LT, 3WL.


R

EFF :

ALL  33-51-00

Page 546
Nov 01/07
 
IAC 
**ON A/C 001-012, 014-099,

Subtask 33-51-00-720-051

D. Test of the left and right escape-hatch switches of the emergency-exit


escape-slide lighting.

WARNING : MAKE SURE THAT THE SAFETY PIN IS CORRECTLY INSTALLED IN THE
_______
HATCH FRAME IF THE EMERGENCY EXIT HATCH IS REMOVED. THIS
PREVENTS AN ACCIDENTAL OPERATION OF THE ESCAPE SLIDE MECHANISM
DURING THE MAINTENANCE.

WARNING : DO NOT OPEN THE EMERGENCY EXITS.


_______

NOTE : This test is for the left emergency exits. The test for the right
____
emergency exits is the same.

(1) Do this Test.


(Ref. TASK 52-21-00-720-001)

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. In the cockpit, on the overhead


circuit breaker panel 49VU:

- make sure that the circuit


breakers, LIGHTING/EMER
LT/CABIN, 1WL and 2WL are
closed.

2. On the forward left emergency Between the left emergency exits:


escape hatch:

- pull down and remove the cover - the SLIDE ARMED light on the cabin
flap from the hatch, lining comes on,

- push the latch pin against the - the SLIDE ARMED light goes off.
spring and turn it a quarter
turn counterclockwise to
retract it to the DISARMED
position,

On the left overwing fuselage:


R

EFF :

001-012, 014-099,  33-51-00

Page 547
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- the overwing emergency lights come
on,

- push the latch pin against the - the overwing emergency lights go off.
spring and turn it a quarter
turn clockwise to extend it to
the ARMED position,

Between the left emergency exits:

- the SLIDE ARMED light comes on,

- install and close the removed - the SLIDE ARMED light goes off.
cover flap on the hatch.

3. On the aft left emergency escape Between the left emergency exits:
hatch:

- pull down and remove the cover - the SLIDE ARMED light comes on,
flap from the hatch,

- push the latch pin against the - the SLIDE ARMED light goes off.
spring and turn it a quarter
turn counterclockwise to
retract it to the DISARMED
position,

On the left overwing fuselage:

- the overwing emergency lights come


on,

- push the latch pin against the - the overwing emergency lights go off.
spring and turn it a quarter
turn clockwise to extend it to
the ARMED position,

Between the left emergency exits:

- the SLIDE ARMED light comes on,

- install and close the removed - the SLIDE ARMED light goes off.
cover flap on the hatch.


R

EFF :

001-012, 014-099,  33-51-00

Page 548
Nov 01/07
 
IAC 
**ON A/C 101-199,

Subtask 33-51-00-720-051-B

D. Test of the forward and rear emergency-exit door switches of the


emergency-exit escape-slide lighting.

WARNING : BEFORE YOU START WORK ON THE DOOR, MAKE SURE THAT:
_______
- THE EMERGENCY CONTROL HANDLE IS IN THE DISARMED POSITION WITH
THE SAFETY PIN INSTALLED.
- THE PERCUSSION LEVER OF THE DOOR-DAMPER AND
EMERGENCY-OPERATION CYLINDER IS IN THE DISARMED POSITION WITH
THE SAFETY PIN INSTALLED.

WARNING : DO NOT OPEN THE EMERGENCY EXITS.


_______

NOTE : Make sure that the EMER EXIT LT switch 4WL on the SIGNS panel 25VU
____
is in the OFF position. This test is for the forward RH/LH
emergency-exit doors. For the rear RH/LH emergency-exit doors use
the information in the brackets.

(1) Do the test of the forward and rear emergency-exit door switches of
the emergency-exit escape-slide lighting.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the aircraft:
- make sure that the related
emergency-exit door is closed.

2. In the cockpit, on the overhead


circuit breaker panel 49VU:
- open the circuit breakers,
LIGHTING EMER LT CABIN, 1WL and
2WL.

3. In the cockpit, on the secondary


circuit breaker panel 122VU:
- open the circuit breaker, CABIN
EMER LT, 3WL.

4. In Zone 231 (251), on the


emergency power-supply unit 15WL
(11WL):


R

EFF :

101-199,  33-51-00

Page 549
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- remove the electrical connector
15WL-A (11WL-A).

5. On the DGTL multimeter:


- connect the positive test lead
of the DGTL multimeter to pin C
(S) of the connector 15WL-A
(11WL-A),
- connect the negative test lead
of the DGTL multimeter to pin m
of the connector 15WL-A
(11WL-A).
- set the DGTL multimeter to the
kilo ohm range.

NOTE : The closed circuit is in the kilo ohm range because the door switches
____
are electronic types.

6. On the forward (rear) left In Zone 231 (251) on the DGTL


emergency-exit door: multimeter:
- remove the safety pin from the
control handle of the escape
slide.

- set the slide control handle to - the DGTL multimeter shows a closed
the ARMED position. circuit.

- set the slide control handle to - the DGTL multimeter shows an open
the DISARMED position. circuit.

- install the safety pin in the


control handle of the escape
slide.

7. On the DGTL multimeter:


- connect the positive test lead
of the DGTL multimeter to pin D
(k) of the connector 15WL-A
(11WL-A),
- connect the negative test lead
of the DGTL multimeter to pin m
of the connector 15WL-A
(11WL-A).


R

EFF :

101-199,  33-51-00

Page 550
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
8. On the forward (rear) left
emergency-exit door:

- lift the door handle - the DGTL multimeter shows an open


approximately 10.0 mm (0.3937 circuit.
in.), but do not open the
emergency-exit door.

- lock the door handle. - the DGTL multimeter shows a closed


circuit.

9. On the DGTL multimeter:


- disconnect the testleads and
remove the DGTL multimeter.

10. On the emergency power-supply


unit 15WL (11WL):
- connect the electrical
connector 15WL-A (11WL-A).

11. In Zone 231 (251), on the


emergency power-supply unit 14WL
(12WL):
- remove the electrical
connector 14WL-A (12WL-A).

12. On the DGTL multimeter:


- connect the positive test lead
of the DGTL multimeter to pin
S of the connector 14WL-A
(12WL-A),
- connect the negative test lead
of the DGTL multimeter to pin
m of the connector 14WL-A
(12WL-A).
- set the DGTL multimeter to the
kilo ohm range.

13. On the forward (rear) right In Zone 231 (251) on the DGTL
emergency-exit door: multimeter:
- remove the safety pin from the
control handle of the escape
slide.



EFF :

101-199,  33-51-00

Page 551
Nov 01/07
R  
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- set the slide control handle - the DGTL multimeter shows a closed
to the ARMED position. circuit.

- set the slide control handle - the DGTL multimeter shows an open
to the DISARMED position. circuit.

- install the safety pin in the


control handle of the escape
slide.

14. On the DGTL multimeter:


- connect the positive test lead
of the DGTL multimeter to pin
k of the connector 14WL-A
(12WL-A),
- connect the negative test lead
of the DGTL multimeter to pin
m of the connector 14WL-A
(12WL-A).

15. On the forward (rear) right


emergency-exit door:

- lift the door handle - the DGTL multimeter shows an open


approximately 10.0 mm (0.3937 circuit.
in.), but do not open the
emergency-exit door.

- lock the door handle. - the DGTL multimeter shows a closed


circuit.

16. On the DGTL multimeter:


- disconnect the test leads and
remove the DGTL multimeter.

17. On the emergency power-supply


unit 14WL (12WL):
- connect the electrical
connector 14WL-A (12WL-A).

18. In the cockpit, on the overhead


circuit breaker panel 49VU:


R

EFF :

101-199,  33-51-00

Page 552
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- close the circuit breakers,
LIGHTING EMER LT CABIN, 1WL
and 2WL.

19. In the cockpit, on the secondary


circuit breaker panel 122VU:
- close the circuit breaker,
CABIN EMER LT, 3WL.

**ON A/C 901-999,

Subtask 33-51-00-720-051-A

D. Test of the left and right escape-hatch switches of the emergency-exit


escape-slide lighting.

WARNING : MAKE SURE THAT THE SAFETY PIN IS CORRECTLY INSTALLED IN THE
_______
HATCH FRAME IF THE EMERGENCY EXIT HATCH IS REMOVED. THIS
PREVENTS AN ACCIDENTAL OPERATION OF THE ESCAPE SLIDE MECHANISM
DURING THE MAINTENANCE.

WARNING : DO NOT OPEN THE EMERGENCY EXITS.


_______

NOTE : This test is for the left emergency exit. The test for the right
____
emergency exit is the same.

(1) Do this Test.


(Ref. TASK 52-21-00-720-001)

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. In the cockpit, on the overhead


circuit breaker panel 49VU:

- make sure that the circuit


breakers, LIGHTING/EMER
LT/CABIN, 1WL and 2WL are
closed.

2. On the left emergency escape At the left emergency exit:


hatch:


R

EFF :

101-199, 901-999,  33-51-00

Page 553
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- pull down and remove the cover - the SLIDE ARMED light on the cabin
flap from the hatch, lining comes on,

- push the latch pin against the - the SLIDE ARMED light goes off.
spring and turn it a quarter
turn counterclockwise to
retract it to the DISARMED
position,

On the left overwing fuselage:

- the overwing emergency lights come


on,

- push the latch pin against the - the overwing emergency lights go off.
spring and turn it a quarter
turn clockwise to extend it to
the ARMED position,

At the left emergency exit:

- the SLIDE ARMED light comes on,

- install and close the removed - the SLIDE ARMED light goes off.
cover flap on the hatch.

R **ON A/C ALL

Subtask 33-51-00-710-055

E. Do the operational test of the emergency lighting system (Ref. TASK 33-
51-00-710-001).
R



EFF :

ALL  33-51-00

Page 554
Nov 01/07
 
IAC 
5. Close-up
________

Subtask 33-51-00-860-054

A. Put the system back to the serviceable condition.

(1) Do the EIS stop procedure


(Ref. TASK 31-60-00-860-002).

(2) Remove the DGTL multimeter.

**ON A/C 001-012, 014-099,

Subtask 33-51-00-410-050

B. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the ceiling panel:


FOR 10WL
install 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-
42-400-001),

(3) Install the door frame lining:


FOR 13WL
install 261KW at the left AFT passenger/crew door (Ref. TASK 25-23-
45-400-008).

(4) Remove the warning notices.

(5) Remove the stepladder(s).



EFF :

ALL  33-51-00

Page 555
Nov 01/07
R  
IAC 
**ON A/C 101-199,

Subtask 33-51-00-410-050-B

B. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the ceiling panel:


FOR 10WL
install 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-
42-400-001),
FOR 11WL
install 251KC between the rear emergency exit doors (Ref. TASK 25-23-
41-400-001),
FOR 12WL
install 251KC between the rear emergency exit doors (Ref. TASK 25-23-
41-400-001),
FOR 14WL
install 231JC between the forward emergency exit doors (Ref. TASK 25-
23-41-400-001),
FOR 15WL
install 231JC between the forward emergency exit doors (Ref. TASK 25-
23-41-400-001),
FOR 13WL
install 261CC at the left AFT passenger/crew door (Ref. TASK 25-23-
42-400-002).

(3) Remove the warning notices.

(4) Remove the stepladder(s).


R

EFF :

101-199,  33-51-00

Page 556
Nov 01/07
 
IAC 
**ON A/C 901-999,

Subtask 33-51-00-410-050-A

B. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the ceiling panel:


FOR 10WL
install 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-
42-400-001),
FOR 13WL
install 261CC at the left AFT passenger/crew door (Ref. TASK 25-23-
42-400-002).

(3) Remove the warning notices.

(4) Remove the stepladder(s).

**ON A/C ALL

Subtask 33-51-00-862-054

C. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-51-00

Page 557
Nov 01/07
R  
IAC 
TASK 33-51-00-710-009

Check all Cabin Lights and Signs for correct illumination

1. __________________
Reason for the Job

Do this check of Cabin Lights and Signs for maintenance.

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

3. __________
Job Set-up

Subtask 33-51-00-861-061

A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-51-00-865-060

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05
122VU LIGHTING/CABIN/EMER/LT 3WL V07


R

EFF :

ALL  33-51-00

Page 558
Nov 01/07
 
IAC 
4. Procedure
_________

**ON A/C 001-012, 014-099,

Subtask 33-51-00-860-063

A. Preparation for Test

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.

Subtask 33-51-00-710-064

B. Test of both Control Panels and the Emergency Lighting System

R NOTE : All the individual lamps in the cabin lights and signs must come
____
R on or go off as necessary during the subsequent test.

R (1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. In the cockpit, on the SIGNS In the cockpit, on the SIGNS panel


panel 25VU: 25VU:
R - Set the EMER EXIT LT switch 4WL - The EMER EXIT LT OFF annunciator 5WL
R to the ON position. goes off.

In the cabin:
R - The signs and the lights of the
R emergency lighting system come on.

2. On the SIGNS panel 25VU: On the SIGNS panel 25VU:


R - Set the EMER EXIT LT switch 4WL - The EMER EXIT LT OFF annunciator 5WL
R to the OFF position. comes on.

In the cabin:
R - The signs and the lights of the
R emergency lighting system go off.


R

EFF :

ALL  33-51-00

Page 559
Nov 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
3. On the FAP 120RH: On the FAP 120RH:
R - Push the LIGHT EMER pushbutton - The red light of the LIGHT EMER
R switch. pushbutton switch comes on.

In the cabin:
R - The signs and the lights of the
R emergency lighting system come on.

4. On the FAP 120RH: On the FAP 120RH:


R - Push the LIGHT EMER pushbutton - The red light of the LIGHT EMER
R switch. pushbutton switch goes off.

In the cabin:
R - The signs and the lights of the
R emergency lighting system go off.

**ON A/C 101-199, 901-999,

Subtask 33-51-00-860-063-A

A. Preparation for Test

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
pushbutton switch and its integral light are off.


R

EFF :

ALL  33-51-00

Page 560
Nov 01/07
 
IAC 
Subtask 33-51-00-710-064-A

B. Test of both Control Panels and the Emergency Lighting System

R NOTE : All the individual lamps in the cabin lights and signs must come
____
R on or go off as necessary during the subsequent test.

R (1) Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. In the cockpit, on the SIGNS In the cockpit, on the SIGNS panel


panel 25VU: 25VU:
R - Set the EMER EXIT LT switch 4WL - The EMER EXIT LT OFF annunciator 5WL
R to the ON position. goes off.

In the cabin:
R - The signs and the lights of the
R emergency lighting system come on.

2. On the SIGNS panel 25VU: On the SIGNS panel 25VU:


R - Set the EMER EXIT LT switch 4WL - The EMER EXIT LT OFF annunciator 5WL
R to the OFF position. comes on.

In the cabin:
R - The signs and the lights of the
R emergency lighting system go off.

3. On the FAP 120RH: On the FAP 120RH:


R - Push the EMER pushbutton - The light of the EMER pushbutton
R switch. switch comes on.

In the cabin:
R - The signs and the lights of the
R emergency lighting system come on.

4. On the FAP 120RH: On the FAP 120RH:


R - Push the EMER pushbutton - The light of the EMER pushbutton
R switch. switch goes off.

In the cabin:
R - The signs and the lights of the
R emergency lighting system go off.



EFF :

101-199, 901-999,  33-51-00

Page 561
Nov 01/07
 
IAC 
**ON A/C ALL

5. Close-up
________

Subtask 33-51-00-862-060

A. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).
R


R

EFF :

ALL  33-51-00

Page 562
Nov 01/07
 
IAC 
LIGHT - EMERGENCY, CABIN (20WL,21WL,28WL,32WL,33WL) - REMOVAL/INSTALLATION
__________________________________________________________________________

TASK 33-51-11-000-001

Removal of the Cabin Emergency Lights

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

NOTE : The procedure is the same for all cabin emergency lights.
____

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-099,

33-51-11-991-001 Fig. 401

**ON A/C 101-199,

R 33-51-11-991-001-D Fig. 401A

R **ON A/C 901-901,

33-51-11-991-001-A Fig. 401B



EFF :

ALL  33-51-11

Page 401
Aug 01/07
 
IAC 
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R **ON A/C 902-999,

R 33-51-11-991-001-C Fig. 401C

**ON A/C 001-012, 014-099,

33-51-11-991-002 Fig. 402

**ON A/C 901-999,

33-51-11-991-002-A Fig. 402A

**ON A/C ALL

3. __________
Job Set-up

Subtask 33-51-11-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05

R **ON A/C 001-012, 014-099,

Subtask 33-51-11-860-050-A

B. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.



EFF :

ALL  33-51-11

Page 402
Aug 01/07
 
IAC 
(3) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.

**ON A/C 101-199,

Subtask 33-51-11-860-050-B

B. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
pushbutton and its internal light are off.

R **ON A/C 901-999,

R Subtask 33-51-11-860-050-C

R B. Aircraft Maintenance Configuration

R (1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
R 4WL is in the OFF position.

R (2) On the overhead panel 25VU, make sure that the NO SMOKING switch
R 190RH is in the OFF position.

R (3) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
R pushbutton and its light are off.

**ON A/C 001-012, 014-099,

Subtask 33-51-11-010-052

C. Get Access

FOR 70WL1
Remove the access panel 241CW.

FOR 70WL2
Remove the access panel 242CW.

FOR 70WL3
Remove the access panel 241LW.



EFF :

ALL  33-51-11

Page 403
Aug 01/07
 
IAC 
FOR 70WL4
Remove the access panel 242LW.

**ON A/C 901-999,

Subtask 33-51-11-010-052-A

C. Get Access

FOR 70WL1
Remove the access panel 241FW.

FOR 70WL2
Remove the access panel 242FW.

**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-51-11-991-001)

**ON A/C 101-199,

R (Ref. Fig. 401A/TASK 33-51-11-991-001-D)

R **ON A/C 901-901,

(Ref. Fig. 401B/TASK 33-51-11-991-001-A)

R **ON A/C 902-999,

R (Ref. Fig. 401C/TASK 33-51-11-991-001-C)

R **ON A/C 001-012, 014-099,

(Ref. Fig. 402/TASK 33-51-11-991-002)



EFF :

ALL  33-51-11

Page 404
Aug 01/07
 
IAC 
**ON A/C 901-999,

(Ref. Fig. 402A/TASK 33-51-11-991-002-A)

**ON A/C 001-012, 014-099,

Subtask 33-51-11-020-050

A. Removal of the Cabin Emergency Light

(1) Removal of the Cabin Emergency-Light Assembly

(a) Carefully remove the lens (2), (6) from the light housing (4),
(7).

(b) Release the attachment clips (5), (9) and remove the light
housing (4), (7) from the mounting hole.

(c) Support the light housing (4), (7) and disconnect the electrical
connectors (1), (8).

(d) Remove the light housing (4), (7).

(2) Removal of the Bulb(s) of the Cabin Emergency Light

(a) Carefully remove the lens (2), (6) from the light housing (4),
(7).

(3) Remove the bulb(s) (3), (10).

R **ON A/C 101-199,

R Subtask 33-51-11-020-050-C

R A. Removal of the Cabin Emergency Light

R (1) Removal of the Cabin Emergency-Light Assembly installed in the


R Ceiling

R (a) Release the attachment clip (3) and remove the light housing (2)
R from the wall panel.

R (b) Hold the light housing (2) and disconnect the electrical
R connectors (4) from the Faston tabs (1).


R

EFF :

ALL  33-51-11

Page 405
Aug 01/07
 
IAC 
Cabin Emergency Light
Figure 401/TASK 33-51-11-991-001- 12 (SHEET 1)


R

EFF :

001-012, 014-099,  33-51-11

Page 406
Feb 01/07
 
IAC 
Cabin Emergency Light
Figure 401/TASK 33-51-11-991-001- 22 (SHEET 2)


R

EFF :

001-012, 014-099,  33-51-11

Page 407
Feb 01/07
 
IAC 
R Cabin Emergency Light
R Figure 401A/TASK 33-51-11-991-001-D12 (SHEET 1)



EFF :

101-199,  33-51-11

Page 408
Aug 01/07
 
IAC 
R Cabin Emergency Light
R Figure 401A/TASK 33-51-11-991-001-D22 (SHEET 2)



EFF :

101-199,  33-51-11

Page 409
Aug 01/07
 
IAC 
R Cabin Emergency Light
Figure 401B/TASK 33-51-11-991-001-A12 (SHEET 1)



EFF :

901-901,  33-51-11

Page 410
May 01/08
 
IAC 
R Cabin Emergency Light
Figure 401B/TASK 33-51-11-991-001-A22 (SHEET 2)



EFF :

901-901,  33-51-11

Page 411
May 01/08
 
IAC 
R Cabin Emergency Light
R Figure 401C/TASK 33-51-11-991-001-C12 (SHEET 1)


R

EFF :

902-999,  33-51-11

Page 412
Aug 01/07
 
IAC 
R Cabin Emergency Light
R Figure 401C/TASK 33-51-11-991-001-C22 (SHEET 2)


R

EFF :

902-999,  33-51-11

Page 413
Aug 01/07
 
IAC 
Cabin Emergency Light - Escape-Hatch Handle Lighting
Figure 402/TASK 33-51-11-991-002


R

EFF :

001-012, 014-099,  33-51-11

Page 414
Aug 01/07
 
IAC 
Cabin Emergency Light - Escape-Hatch Handle Lighting
Figure 402A/TASK 33-51-11-991-002-A


R

EFF :

901-999,  33-51-11

Page 415
Aug 01/07
 
IAC 
R (c) Remove the light housing (2).

R (d) Put blanking caps on the disconnected electrical connectors.

R (2) Removal of the Cabin Emergency-Light Assembly installed in the


R Door-Area

R (a) Carefully remove the lens (5), (12) from the light housing (6),
R (10).

R (b) Release the attachment clips (8), (11) and remove the light
R housing (6), (10) from the mounting hole.

R (c) Hold the light housing (6), (10) and disconnect the electrical
R connectors (7), (9).

R (d) Remove the light housing (6), (10).

R **ON A/C 901-901,

Subtask 33-51-11-020-050-A

A. Removal of the Cabin Emergency Light

(1) Removal of the Cabin Emergency-Light Assembly mounted in the Ceiling

(a) Carefully remove the lens (3) from the light housing (4).

(b) Remove the screws (1) and remove the light housing (4) from the
mounting hole.

(c) Support the light housing (4) and disconnect the electrical
connector (2).

(d) Remove the light housing (4).

(e) Put blanking caps on the disconnected electrical connectors.

(2) Removal of the Cabin Emergency-Light Assembly mounted in the


Door-Area

(a) Carefully remove the lens (5) from the light housing (6).

(b) Release the attachment clips (8) and remove the light housing (6)
from the mounting hole.


R

EFF :

101-199, 901-901,  33-51-11

Page 416
Aug 01/07
 
IAC 
(c) Support the light housing (6) and disconnect the electrical
connectors (7).

(d) Remove the light housing (6).

R **ON A/C 902-999,

R Subtask 33-51-11-020-050-D

R A. Removal of the Cabin Emergency Light

R (1) Removal of the Cabin Emergency-Light Assembly installed in the


R Ceiling

R (a) Release the attachment clip (3) and remove the light housing (2)
R from the wall panel.

R (b) Hold the light housing (2) and disconnect the electrical
R connectors (4) from the Faston tabs (1).

R (c) Remove the light housing (2).

R (d) Put blanking caps on the disconnected electrical connectors.

R (2) Removal of the Cabin Emergency-Light Assembly installed in the


R Door-Area

R (a) Carefully remove the lens (5) from the light housing (6).

R (b) Release the attachment clips (8) and remove the light housing (6)
R from the mounting hole.

R (c) Hold the light housing (6) and disconnect the electrical
R connectors (7).

R (d) Remove the light housing (6).


R

EFF :

901-999,  33-51-11

Page 417
Aug 01/07
 
IAC 
**ON A/C 001-012, 014-099,

Subtask 33-51-11-020-051

B. Removal of the Escape Hatch-Handle Light

(1) Removal of the Escape Hatch-Handle Light-Assembly

(a) Disconnect the electrical connectors (19).

(b) Release the spring clips (18) and remove the escape hatch-handle
light (15).

(2) Removal of the Bulb(s) of the Escape Hatch-Handle Light

(a) Remove the lens (17) from the light housing.

(b) Remove the bulb(s) (16).

**ON A/C 901-999,

Subtask 33-51-11-020-051-A

B. Removal of the Escape Hatch-Handle Light

(1) Removal of the Escape Hatch-Handle Light-Assembly

(a) Disconnect the electrical connectors (17).

(b) Release the spring clips (16) and remove the escape hatch-handle
light (15).


R

EFF :

001-012, 014-099, 901-999,  33-51-11

Page 418
Aug 01/07
 
IAC 
**ON A/C ALL

TASK 33-51-11-400-001

Installation of the Cabin Emergency Light

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied


from the External Power

**ON A/C 001-012, 014-099,

33-51-11-991-001 Fig. 401

**ON A/C 101-199,

R 33-51-11-991-001-D Fig. 401A

R **ON A/C 901-901,

33-51-11-991-001-A Fig. 401B

R **ON A/C 902-999,

R 33-51-11-991-001-C Fig. 401C

**ON A/C 001-012, 014-099,

33-51-11-991-002 Fig. 402



EFF :

ALL  33-51-11

Page 419
Aug 01/07
 
IAC 
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 901-999,

33-51-11-991-002-A Fig. 402A

**ON A/C ALL

3. __________
Job Set-up

R **ON A/C 001-012, 014-099,

Subtask 33-51-11-860-051-A

A. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.

**ON A/C 101-199,

Subtask 33-51-11-860-051-B

A. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
pushbutton and its internal light are off.


R

EFF :

ALL  33-51-11

Page 420
Aug 01/07
 
IAC 
R **ON A/C 901-999,

R Subtask 33-51-11-860-051-C

R A. Aircraft Maintenance Configuration

R (1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
R 4WL is in the OFF position.

R (2) On the overhead panel 25VU, make sure that the NO SMOKING switch
R 190RH is in the OFF position.

R (3) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
R pushbutton and its light are off.

**ON A/C 001-012, 014-099,

Subtask 33-51-11-010-054

B. Make sure that the access panels 241CW, 242CW, 241LW, 242LW are open.

**ON A/C 901-999,

Subtask 33-51-11-010-054-A

B. Make sure that the access panels 241FW, 242FW are open.

**ON A/C ALL

Subtask 33-51-11-865-053

C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05


R

EFF :

ALL  33-51-11

Page 421
Aug 01/07
 
IAC 
4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-51-11-991-001)

**ON A/C 101-199,

R (Ref. Fig. 401A/TASK 33-51-11-991-001-D)

R **ON A/C 901-901,

(Ref. Fig. 401B/TASK 33-51-11-991-001-A)

R **ON A/C 902-999,

R (Ref. Fig. 401C/TASK 33-51-11-991-001-C)

R **ON A/C 001-012, 014-099,

(Ref. Fig. 402/TASK 33-51-11-991-002)

**ON A/C 901-999,

(Ref. Fig. 402A/TASK 33-51-11-991-002-A)

**ON A/C ALL

Subtask 33-51-11-910-050

A. Preparation for Installation

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Clean the component interface and/or the adjacent area.

(3) Do an inspection of the component interface and/or the adjacent area.


R

EFF :

ALL  33-51-11

Page 422
Aug 01/07
 
IAC 
**ON A/C 001-012, 014-099,

Subtask 33-51-11-420-050

B. Installation of the Cabin Emergency Light

(1) Installation of the Cabin Emergency-Light Assembly

(a) Make sure that the electrical connectors are clean and in the
correct condition.

(b) Connect the electrical connectors (1), (8) to the light housing
(4), (7).

(c) Install the light housing (4), (7).


Make sure that you hear a click when the light housing (4), (7)
locks in position.

(d) Install the lens (2), (6) to the light housing (4), (7).
Make sure that you hear a click when the lens (2), (6) locks in
position.

(2) Installation of the Bulb(s) of the Cabin Emergency Light

(a) Install the bulb(s) (3), (10) in the light housing (4), (7).

(b) Install the lens (2), (6) to the light housing (4), (7).
Make sure that you hear a click when the lens (2), (6) locks in
position.

R **ON A/C 101-199,

R Subtask 33-51-11-420-050-C

R B. Installation of the Cabin Emergency Light

R (1) Installation of the Cabin Emergency-Light Assembly installed in the


R Ceiling

R (a) Remove the blanking caps from the electrical connectors.

R (b) Make sure that the electrical connectors are clean and in the
R correct condition.

R (c) Connect the electrical connectors (4) to the Faston tabs (1).


R

EFF :

001-012, 014-099, 101-199,  33-51-11

Page 423
Aug 01/07
 
IAC 
R (d) Install the light housing (2) on the wall panel.
R Make sure that you hear a click when the light housing (2) locks
R in position.

R (2) Installation of the Cabin Emergency-Light Assembly installed in the


R Door-Area

R (a) Make sure that the electrical connectors are clean and in the
R correct condition.

R (b) Connect the electrical connectors (7), (9) to the light housing
R (6), (10).

R (c) Install the light housing (6), (10).


R Make sure that you hear a click when the light housing (6), (10)
R locks in position.

R (d) Install the lens (5), (12) on the light housing (6), (10).
R Make sure that you hear a click when the lens (5), (12) locks in
R position.

R **ON A/C 901-901,

Subtask 33-51-11-420-050-A

B. Installation of the Cabin Emergency Light

(1) Installation of the Cabin Emergency-Light Assembly mounted in the


Ceiling

(a) Remove the blanking caps from the electrical connectors.

(b) Make sure that the electrical connectors are clean and in the
correct condition.

(c) Connect the electrical connector (2) to the light housing (4).

(d) Install the light housing (4) with the screws (1).

(e) Install the lens (3) to the light housing (4).


Make sure that you hear a click when the lens (3) locks in
position.


R

EFF :

101-199, 901-901,  33-51-11

Page 424
Aug 01/07
 
IAC 
(2) Installation of the Cabin Emergency-Light Assembly mounted in the
Door-Area

(a) Make sure that the electrical connectors are clean and in the
correct condition.

(b) Connect the electrical connectors (7) to the light housing (6).

(c) Install the light housing (6).


Make sure that you hear a click when the light housing (6) locks
in position.

(d) Install the lens (5) to the light housing (6).


Make sure that you hear a click when the lens (5) locks in
position.

R **ON A/C 902-999,

R Subtask 33-51-11-420-050-D

R B. Installation of the Cabin Emergency Light

R (1) Installation of the Cabin Emergency-Light Assembly installed in the


R Ceiling

R (a) Remove the blanking caps from the electrical connectors.

R (b) Make sure that the electrical connectors are clean and in the
R correct condition.

R (c) Connect the electrical connectors (4) to the Faston tabs (1).

R (d) Install the light housing (2) on the wall panel.


R Make sure that you hear a click when the light housing (2) locks
R in position.

R (2) Installation of the Cabin Emergency-Light Assembly installed in the


R Door-Area

R (a) Make sure that the electrical connectors are clean and in the
R correct condition.

R (b) Connect the electrical connectors (7) to the light housing (6).



EFF :

901-999,  33-51-11

Page 425
Aug 01/07
 
IAC 
R (c) Install the light housing (6).
R Make sure that you hear a click when the light housing (6) locks
R in position.

R (d) Install the lens (5) on the light housing (6).


R Make sure that you hear a click when the lens (5) locks in
R position.

**ON A/C 001-012, 014-099,

Subtask 33-51-11-420-052

C. Installation of the Escape Hatch-Handle Light

(1) Installation of the Escape Hatch-Handle Light-Assembly

(a) Install the escape hatch-handle light (15).


Make sure that you hear a click when the escape hatch-handle
light (15) locks in position.

(b) Make sure that the electrical connectors are clean and in the
correct condition.

(c) Connect the electrical connectors (19) to the escape-hatch handle


light (15).

(2) Installation of the Bulb(s) of the Escape Hatch-Handle Light

(a) Install the bulb(s) (16) in the light housing.

(b) Install the lens (17) to the light housing.

**ON A/C 901-999,

Subtask 33-51-11-420-052-A

C. Installation of the Escape Hatch-Handle Light

(1) Installation of the Escape Hatch-Handle Light-Assembly

(a) Install the escape hatch-handle light (15).


Make sure that you hear a click when the escape hatch-handle
light (15) locks in position.



EFF :

001-012, 014-099, 901-999,  33-51-11

Page 426
Aug 01/07
 
IAC 
(b) Make sure that the electrical connectors are clean and in the
correct condition.

R (c) Connect the electrical connectors (17) to the escape hatch-handle


R light (15).

**ON A/C ALL

Subtask 33-51-11-865-051

D. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1WL, 2WL.

Subtask 33-51-11-861-050

E. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).

Subtask 33-51-11-710-050

F. Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. In the cockpit on the SIGNS panel In the cockpit, on the SIGNS panel
25VU: 25VU:
- set the EMER EXIT LT switch 4WL - the EMER EXIT LT OFF annunciator 5WL
to the ON position. goes off.
In the cabin:
- the related emergency light comes on.

2. In the cockpit, on the SIGNS In the cockpit, on the SIGNS panel


panel 25VU: 25VU:
- set the EMER EXIT LT switch 4WL - the EMER EXIT LT OFF annunciator 5WL
to the OFF position. comes on.
In the cabin:
- the related emergency light goes off.



EFF :

ALL  33-51-11

Page 427
Feb 01/08
 
IAC 
5. Close-up
________

**ON A/C 001-012, 014-099,

Subtask 33-51-11-410-053

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the access panels 241CW, 242CW, 241LW, 242LW.

**ON A/C 901-999,

Subtask 33-51-11-410-053-A

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the access panels 241FW, 242FW.

**ON A/C ALL

Subtask 33-51-11-862-050

B. De-energize the aircraft electrical circuit (Ref. TASK 24-41-00-862-002).



EFF :

ALL  33-51-11

Page 428
Aug 01/07
 
IAC 
SIGN - EXIT MARKING, WALL MOUNTED - REMOVAL/INSTALLATION
________________________________________________________

TASK 33-51-13-000-001

Removal of the Cabin Wall-Mounted Emergency-Exit-Markers

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

NOTE : The procedure is the same for all wall-mounted emergency-exit-markers.


____

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific insertion/removal tool M 15.570-22
R

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-099,

33-51-13-991-001 Fig. 401

**ON A/C 101-199,

33-51-13-991-001-C Fig. 401A



EFF :

ALL  33-51-13

Page 401
Aug 01/07
 
IAC 
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R **ON A/C 901-999,

33-51-13-991-001-A Fig. 401B

**ON A/C ALL

3. __________
Job Set-up

Subtask 33-51-13-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05

R **ON A/C 001-012, 014-099,

Subtask 33-51-13-860-050

B. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.



EFF :

ALL  33-51-13

Page 402
Aug 01/07
 
IAC 
R **ON A/C 101-199, 901-999,

Subtask 33-51-13-860-050-A

B. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
pushbutton and its internal light are off.

**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-51-13-991-001)

**ON A/C 101-199,

(Ref. Fig. 401A/TASK 33-51-13-991-001-C)

R **ON A/C 901-999,

(Ref. Fig. 401B/TASK 33-51-13-991-001-A)



EFF :

ALL  33-51-13

Page 403
Aug 01/07
 
IAC 
Cabin Wall-Mounted Emergency-Exit-Markers
Figure 401/TASK 33-51-13-991-001


R

EFF :

001-012, 014-099,  33-51-13

Page 404
May 01/07
 
IAC 
R Cabin Wall-Mounted Emergency-Exit-Markers
R Figure 401A/TASK 33-51-13-991-001-C


R

EFF :

101-199,  33-51-13

Page 405
May 01/07
 
IAC 
Cabin Wall-Mounted Emergency-Exit-Markers
Figure 401B/TASK 33-51-13-991-001-A


R

EFF :

901-999,  33-51-13

Page 406
Aug 01/07
 
IAC 
**ON A/C 001-012, 014-099,

Subtask 33-51-13-020-050

A. Removal of the Cabin Wall-Mounted Emergency-Exit Markers

(1) Removal of the Emergency-Exit-Marker Assembly

(a) Remove the screw (4) from the lens (5).

(b) Carefully remove the lens (5) from the light housing (6).

(c) Remove the screws (3) and the washers (2) from the light housing
(6).

(d) Remove the light housing (6) from the wall panel.

(e) Support the light housing (6) and disconnect the electrical
connections (7) with the insertion/removal tool M 15.570-22.

(f) Remove the light housing (6).

(2) Removal of the Bulb(s) of the Emergency-Exit-Marker

(a) Remove the screw (4) from the lens (5).

(b) Carefully remove the lens (5) from the light housing (6).

(c) Remove the bulb(s) (1).

R **ON A/C 101-199, 901-999,

Subtask 33-51-13-020-050-B

A. Removal of the Cabin Wall-Mounted Emergency-Exit-Markers

(1) Carefully remove the lens (3) from the light housing (2).

(2) Release the two attachment clips (1) and remove the light housing (2)
from the wall panel.

(3) Support the light housing (2) and disconnect the electrical
connectors (4).


R

EFF :

ALL  33-51-13

Page 407
Aug 01/07
 
IAC 
(4) Remove the light housing (2).
R



EFF :

101-199, 901-999,  33-51-13

Page 408
Aug 01/07
 
IAC 
**ON A/C ALL

TASK 33-51-13-400-001

Installation of the Cabin Wall-Mounted Emergency-Exit-Markers

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

NOTE : The procedure is the same for all wall-mounted emergency-exit-markers.


____

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific insertion/removal tool M15.570-22

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

**ON A/C 001-012, 014-099,

33-51-13-991-001 Fig. 401

**ON A/C 101-199,

R 33-51-13-991-001-C Fig. 401A



EFF :

ALL  33-51-13

Page 409
May 01/07
 
IAC 
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R **ON A/C 901-999,

33-51-13-991-001-A Fig. 401B

**ON A/C ALL

3. __________
Job Set-up

R **ON A/C 001-012, 014-099,

Subtask 33-51-13-860-052

A. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.

R **ON A/C 101-199, 901-999,

Subtask 33-51-13-860-052-A

A. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
pushbutton and its internal light are off.



EFF :

ALL  33-51-13

Page 410
Aug 01/07
 
IAC 
**ON A/C ALL

Subtask 33-51-13-865-055

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-51-13-991-001)

**ON A/C 101-199,

(Ref. Fig. 401A/TASK 33-51-13-991-001-C)

R **ON A/C 901-999,

(Ref. Fig. 401B/TASK 33-51-13-991-001-A)

**ON A/C 001-012, 014-099,

Subtask 33-51-13-420-050

A. Installation of the Cabin Wall-Mounted Emergency-Exit Markers

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Installation of the Emergency-Exit-Marker Assembly

(a) Make sure that the electrical connectors are clean and in the
correct condition.



EFF :

ALL  33-51-13

Page 411
Aug 01/07
 
IAC 
(b) Connect the electrical connections (7) with the insertion/removal
tool M15.570-22.

(c) Install the light housing (6) with the washers (2) and the screws
(3) to the wall panel.

(d) Install the lens (5) with the screw (4) to the light housing (6).

(4) Installation of the Bulb(s) of the Emergency-Exit-Marker

(a) Install the bulb(s) (1) in the light housing (6).

(b) Install the lens (5) with the screw (4) to the light housing (6).

R **ON A/C 101-199, 901-999,

Subtask 33-51-13-420-050-B

A. Installation of the Cabin Wall-Mounted Emergency-Exit-Markers

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Installation of the Emergency-Exit-Marker Assembly

(a) Make sure that the electrical connectors are clean and in the
correct condition.

(b) Connect the electrical connectors (4) to the light housing (2).

(c) Install the light housing (2) to the wall panel.


Make sure that you hear a click when the light housing (2) locks
in position.

(d) Install the lens (3) to the light housing (2).


Make sure that you hear a click when the lens (3) locks in
position.
R


R

EFF :

ALL  33-51-13

Page 412
Aug 01/07
 
IAC 
**ON A/C ALL

Subtask 33-51-13-865-051

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1WL, 2WL.

Subtask 33-51-13-860-051

C. Preparation for the Test

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the overhead panel 25VU, make sure that the EMER EXIT LT OFF
annunciator light 5WL is on.

Subtask 33-51-13-710-050

D. Do this test:

NOTE : The time taken to do this test should not exceed 3 min to prevent
____
discharge of the emergency lighting batteries.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the overhead panel 25VU: On the overhead panel 25VU:


- set the EMER EXIT LT switch 4WL - the EMER EXIT LT OFF annunciator
to the ON position. light 5WL goes off.

In the cabin:
- the related wall-mounted
emergency-exit-marker comes on.

2. On the overhead panel 25VU: On the overhead panel 25VU:


- set the EMER EXIT LT switch 4WL - the EMER EXIT LT OFF annunciator
to the OFF position. light 5WL comes on.

In the cabin:



EFF :

ALL  33-51-13

Page 413
Aug 01/07
R  
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
- the related wall-mounted
emergency-exit-marker goes off.

5. Close-up
________

Subtask 33-51-13-860-053

A. Put the aircraft back to the serviceable condition.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-51-13

Page 414
Aug 01/07
R  
IAC 
R LIGHT - AUXILIARY, LAVATORY (80WL,81WL,82WL,83WL) - REMOVAL/INSTALLATION
________________________________________________________________________

R **ON A/C 001-012, 014-099,

TASK 33-51-14-000-001

Removal of the Auxiliary Lavatory Light 80WL

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific insertion/removal tool M15.570-22
No specific stepladder 1.0 m (3 ft. 3 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-019,

33-51-14-991-001 Fig. 401

**ON A/C 020-099,

33-51-14-991-001-A Fig. 401A



EFF :

ALL  33-51-14

Page 401
May 01/06
 
IAC 
R **ON A/C 001-012, 014-099,

3. __________
Job Set-up

Subtask 33-51-14-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 79WL H07

Subtask 33-51-14-010-050

B. Get Access

(1) Put the stepladder in position below access panel 221AC.

(2) Remove the access panel 221AC.

4. Procedure
_________

**ON A/C 001-012, 014-019,

(Ref. Fig. 401/TASK 33-51-14-991-001)

**ON A/C 020-099,

(Ref. Fig. 401A/TASK 33-51-14-991-001-A)

**ON A/C 001-012, 014-019,

Subtask 33-51-14-020-050

A. Removal of the Auxiliary Lavatory Light

(1) Disconnect the electrical connections (3) with the insertion/removal


tool M15.570-22 from the auxiliary lavatory light (4).

(2) Remove the screws (1), the washers (2) and the auxiliary lavatory
light (4) from the lavatory structure.


R

EFF :

001-012, 014-099,  33-51-14

Page 402
May 01/06
 
IAC 
Auxiliary Lavatory Light 80WL
Figure 401/TASK 33-51-14-991-001



EFF :

001-012, 014-019,  33-51-14

Page 403
Feb 01/96
 
IAC 
Auxiliary Lavatory Light 80WL
Figure 401A/TASK 33-51-14-991-001-A


R

EFF :

020-099,  33-51-14

Page 404
May 01/03
 
IAC 
**ON A/C 020-099,

Subtask 33-51-14-020-050-A

A. Removal of the Auxiliary Lavatory Light

(1) Disconnect the electrical connections (4) with the insertion/removal


tool M15.570-22 from the auxiliary lavatory light (3).

(2) Remove the screws (1), the washers (2) and the auxiliary lavatory
light (3) from the lavatory structure.



EFF :

020-099,  33-51-14

Page 405
May 01/06
R  
IAC 
R **ON A/C 001-012, 014-099,

TASK 33-51-14-400-001

Installation of the Auxiliary Lavatory Light 80WL

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific insertion/removal tool M15.570-22


No specific stepladder 1.0 m (3 ft. 3 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
26-17-00-750-002 Check the Lavatory Air-Extraction Airflow

**ON A/C 001-012, 014-019,

33-51-14-991-001 Fig. 401

**ON A/C 020-099,

33-51-14-991-001-A Fig. 401A


R

EFF :

001-012, 014-099,  33-51-14

Page 406
May 01/06
 
IAC 
R **ON A/C 001-012, 014-099,

3. __________
Job Set-up

Subtask 33-51-14-860-050

A. Aircraft Maintenance Configuration

(1) Make sure that the stepladder is in position below access panel
221AC.

(2) Make sure that the access panel 221AC is removed.

Subtask 33-51-14-865-066

B. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 79WL H07

4. Procedure
_________

**ON A/C 001-012, 014-019,

(Ref. Fig. 401/TASK 33-51-14-991-001)

**ON A/C 020-099,

(Ref. Fig. 401A/TASK 33-51-14-991-001-A)

**ON A/C 001-012, 014-019,

Subtask 33-51-14-420-050

A. Installation of the Auxiliary Lavatory Light

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.


R

EFF :

001-012, 014-099,  33-51-14

Page 407
May 01/06
 
IAC 
(3) Connect the electrical connections (3) with the insertion/removal
tool M15.570-22 to the auxiliary lavatory light (4).

(4) Install the auxiliary lavatory light (4) to the lavatory structure
with the washers (2) and the screws (1).

**ON A/C 020-099,

Subtask 33-51-14-420-050-A

A. Installation of the Auxiliary Lavatory Light

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Connect the electrical connections (4) with the insertion/removal


tool M15.570-22 to the auxiliary lavatory light (3).

(4) Install the auxiliary lavatory light (3) to the lavatory structure
with the washers (2) and the screws (1).

R **ON A/C 001-012, 014-099,

Subtask 33-51-14-861-050

B. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-51-14-865-054

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
79WL.

Subtask 33-51-14-710-055

D. Test

(1) Make sure that the auxiliary lavatory light 80WL comes on. when the
circuit breaker has been closed.

(2) Do the operational test of the lavatory air-extraction airflow


(Ref. TASK 26-17-00-750-002).


R

EFF :

001-012, 014-099,  33-51-14

Page 408
May 01/06
 
IAC 
5. Close-up
________

Subtask 33-51-14-410-055

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Close the access panel 221AC.

(3) Remove the stepladder.

Subtask 33-51-14-862-051

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).


R

EFF :

001-012, 014-099,  33-51-14

Page 409
May 01/06
 
IAC 
TASK 33-51-14-000-002

Removal of the Auxiliary Lavatory Light 81WL

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific insertion/removal tool M15.570-22
No specific stepladder 1.0 m (3 ft. 3 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-019,

33-51-14-991-002 Fig. 402

**ON A/C 020-099,

33-51-14-991-002-A Fig. 402A


R

EFF :

001-012, 014-099,  33-51-14

Page 410
May 01/06
 
IAC 
R **ON A/C 001-012, 014-099,

3. __________
Job Set-up

Subtask 33-51-14-865-051

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 79WL H07

**ON A/C 001-012, 014-019,

Subtask 33-51-14-010-051

B. Get Access

(1) Put a stepladder in position at lavatory D.

**ON A/C 020-099,

Subtask 33-51-14-010-051-A

B. Get Access

(1) Put a stepladder in position at lavatory D.

(2) Remove the ceiling panel 261BC.

R **ON A/C 001-012, 014-099,

4. Procedure
_________

**ON A/C 001-012, 014-019,

(Ref. Fig. 402/TASK 33-51-14-991-002)


R

EFF :

001-012, 014-099,  33-51-14

Page 411
May 01/06
 
IAC 
Auxiliary Lavatory Light 81WL
Figure 402/TASK 33-51-14-991-002



EFF :

001-012, 014-019,  33-51-14

Page 412
Feb 01/96
 
IAC 
R **ON A/C 020-099,

(Ref. Fig. 402A/TASK 33-51-14-991-002-A)

**ON A/C 001-012, 014-019,

Subtask 33-51-14-020-051

A. Removal of the Auxiliary Lavatory Light

(1) Remove the screws (2) from the lavatory ceiling panel (3).

(2) Lower the lavatory ceiling panel (3) to the full length of the
retainer strips (1).

(3) Remove the srews (6), the washers (5) and the cover (7) from the
lavatory ceiling panel (3).

(4) Disconnect the electrical connections (10) with the insertion/removal


tool M15.570-22 from the auxiliary lavatory light (4).

(5) Remove the screws (8), the washers (9) and the auxiliary lavatory
light (4) from the lavatory ceiling panel (3).

R **ON A/C 020-099,

Subtask 33-51-14-020-051-A

A. Removal of the Auxiliary Lavatory Light

(1) Disconnect the electrical connections (4) with the insertion/removal


tool M15.570-22 from the auxiliary lavatory light (3).

(2) Remove the screws (1), the washers (2) and the auxiliary lavatory
light (3) from the lavatory structure.



EFF :

ALL  33-51-14

Page 413
May 01/03
 
IAC 
Auxiliary Lavatory Light 81WL
Figure 402A/TASK 33-51-14-991-002-A


R

EFF :

020-099,  33-51-14

Page 414
May 01/03
 
IAC 
R **ON A/C 001-012, 014-099,

TASK 33-51-14-400-002

Installation of the Auxiliary Lavatory Light 81WL

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific insertion/removal tool M15.570-22


No specific stepladder 1.0 m (3 ft. 3 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
26-17-00-750-002 Check the Lavatory Air-Extraction Airflow

**ON A/C 001-012, 014-019,

33-51-14-991-002 Fig. 402

**ON A/C 020-099,

33-51-14-991-002-A Fig. 402A


R

EFF :

001-012, 014-099,  33-51-14

Page 415
May 01/06
 
IAC 
R **ON A/C 001-012, 014-099,

3. __________
Job Set-up

Subtask 33-51-14-865-067

A. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 79WL H07

**ON A/C 001-012, 014-019,

Subtask 33-51-14-410-060

B. Aircraft Maintenance Configuration

(1) Make sure that the stepladder in in position at lavatory D.

**ON A/C 020-099,

Subtask 33-51-14-410-060-A

B. Aircraft Maintenance Configuration

(1) Make sure that the stepladder in in position at lavatory D.

(2) Make sure that the ceiling panel 261BC is open.

R **ON A/C 001-012, 014-099,

4. Procedure
_________

**ON A/C 001-012, 014-019,

(Ref. Fig. 402/TASK 33-51-14-991-002)


R

EFF :

001-012, 014-099,  33-51-14

Page 416
May 01/06
 
IAC 
**ON A/C 020-099,

(Ref. Fig. 402A/TASK 33-51-14-991-002-A)

**ON A/C 001-012, 014-019,

Subtask 33-51-14-420-051

A. Installation of the Auxiliary Lavatory Light

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Connect the electrical connections (10) with the insertion/removal


tool M15.570-22 to the auxiliary lavatory light (4).

(4) Install the auxiliary lavatory light (4) to the lavatory structure
with the washers (9) and the screws (8).

CAUTION : MAKE SURE THAT THE AIR EXTRACTION GRILL, THE SMOKE DETECTOR
_______
AND THE AIR EXTRACTION DUCT ARE IN LINE WITH THE EXTRACTOR
AIRFLOW.
INCORRECT INSTALLATION CAN CAUSE MALFUNCTION OF THE SMOKE
DETECTOR.

(5) Install the cover (7) with the washers (5) and the screws (6).

(6) Install the lavatory ceiling panel (3) with the screws (2).

(7) Make sure that the auxiliary lavatory light (4) in the air extraction
grill (11) does nut cover the air extraction-duct inlet.

**ON A/C 020-099,

Subtask 33-51-14-420-051-A

A. Installation of the Auxiliary Lavatory Light

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.


R

EFF :

001-012, 014-099,  33-51-14

Page 417
May 01/06
 
IAC 
(3) Connect the electrical connections (4) with the insertion/removal
tool M15.570-22 to the auxiliary lavatory light (3).

(4) Install the auxiliary lavatory light (3) to the lavatory structure
with the washers (2) and the screws (1).

R **ON A/C 001-012, 014-099,

Subtask 33-51-14-861-051

B. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-51-14-865-055

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
79WL.

Subtask 33-51-14-710-056

D. Test

(1) Make sure that the auxiliary lavatory light 81WL comes on when you
close the circuit breaker.

(2) Do the operational test of the lavatory air-extraction airflow


(Ref. TASK 26-17-00-750-002).

5. Close-up
________

**ON A/C 001-012, 014-019,

Subtask 33-51-14-410-061

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Remove the stepladder.


R

EFF :

001-012, 014-099,  33-51-14

Page 418
May 01/06
 
IAC 
**ON A/C 020-099,

Subtask 33-51-14-410-061-A

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the ceiling panel 261BC.

(3) Remove the stepladder.

R **ON A/C 001-012, 014-099,

Subtask 33-51-14-862-052

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).


R

EFF :

001-012, 014-099,  33-51-14

Page 419
May 01/06
 
IAC 
TASK 33-51-14-000-004

Removal of the Auxiliary Lavatory Light 83WL

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific insertion/removal tool M15.570-22
No specific stepladder 1.0 m (3 ft. 3 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-019,

33-51-14-991-004 Fig. 403

**ON A/C 020-099,

33-51-14-991-004-A Fig. 403A


R

EFF :

001-012, 014-099,  33-51-14

Page 420
May 01/06
 
IAC 
**ON A/C 001-012, 014-099,

3. __________
Job Set-up

Subtask 33-51-14-865-053

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 79WL H07

Subtask 33-51-14-010-055

B. Get Access

(1) Put the stepladder in position below the access panel 261AC.

(2) Remove the access panel 261AC.

4. Procedure
_________

**ON A/C 001-012, 014-019,

(Ref. Fig. 403/TASK 33-51-14-991-004)

**ON A/C 020-099,

(Ref. Fig. 403A/TASK 33-51-14-991-004-A)

**ON A/C 001-012, 014-019,

Subtask 33-51-14-020-055

A. Removal of the Auxiliary Lavatory Light

(1) Remove the clamp (2) from the lavatory ventilation flexible-hose (1).

(2) Lift the lavatory ventilation flexible-hose (1) clear of the cover
(9).

(3) Remove the screws (3), the washers (4) and the cover (9).



EFF :

001-012, 014-099,  33-51-14

Page 421
Nov 01/06
R  
IAC 
Auxiliary Lavatory Light 83WL
Figure 403/TASK 33-51-14-991-004



EFF :

001-012, 014-019,  33-51-14

Page 422
Feb 01/96
 
IAC 
Auxiliary Lavatory Light 83WL
Figure 403A/TASK 33-51-14-991-004-A


R

EFF :

020-099,  33-51-14

Page 423
May 01/03
 
IAC 
(4) Disconnect the electrical connections (6) with the insertion/removal
tool M15.570-22 from the auxiliary lavatory light (5).

(5) Remove the screws (8), the washers (7) and the auxiliary lavatory
light (5).

**ON A/C 020-099,

Subtask 33-51-14-020-055-A

A. Removal of the Auxiliary Lavatory Light

(1) Disconnect the electrical connections (4) with the insertion/removal


tool M15.570-22 from the auxiliary lavatory light (3).

(2) Remove the screws (1), the washers (2) and the auxiliary lavatory
light (3).


R

EFF :

001-012, 014-099,  33-51-14

Page 424
Nov 01/06
 
IAC 
R **ON A/C 001-012, 014-099,

TASK 33-51-14-400-004

Installation of the Auxiliary Lavatory Light 83WL

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific insertion/removal tool M15.570-22


No specific stepladder 1.0 m (3 ft. 3 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
26-17-00-750-002 Check the Lavatory Air-Extraction Airflow

**ON A/C 001-012, 014-019,

33-51-14-991-004 Fig. 403

**ON A/C 020-099,

33-51-14-991-004-A Fig. 403A


R

EFF :

001-012, 014-099,  33-51-14

Page 425
May 01/06
 
IAC 
R **ON A/C 001-012, 014-099,

3. __________
Job Set-up

Subtask 33-51-14-865-069

A. Make sure that this(these) circuit breaker(s) is(are) closed:

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 79WL H07

Subtask 33-51-14-860-051

B. Aircraft Maintenance Configuration

(1) Make sure that the stepladder is in position below the access panel
261AC.

(2) Make sure that the access panel 261AC is removed.

4. Procedure
_________

**ON A/C 001-012, 014-019,

(Ref. Fig. 403/TASK 33-51-14-991-004)

**ON A/C 020-099,

(Ref. Fig. 403A/TASK 33-51-14-991-004-A)

**ON A/C 001-012, 014-019,

Subtask 33-51-14-420-056

A. Installation of the Auxiliary Lavatory Light

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.


R

EFF :

001-012, 014-099,  33-51-14

Page 426
May 01/06
 
IAC 
(3) Install the auxiliary lavatory light (5) to the lavatory structure
with the washers (7) and the screws (8).

(4) Connect the electrical connections (6) with the insertion/removal


tool M15.570-22 to the auxiliary lavatory light (5).

CAUTION : MAKE SURE THAT THE AIR EXTRACTION GRILL, THE SMOKE DETECTOR
_______
AND THE AIR EXTRACTION DUCT ARE IN LINE WITH THE EXTRACTOR
AIRFLOW.
INCORRECT INSTALLATION CAN CAUSE MALFUNCTION OF THE SMOKE
DETECTOR.

(5) Install the cover (9) with the washers (4) and the screws (3).

(6) Make sure that the auxiliary lavatory light (5) in the air extraction
grill (10) does not cover the air extraction-duct inlet.

(7) Lower the lavatory ventilation flexible-hose (1) onto the cover (9).

**ON A/C 020-099,

Subtask 33-51-14-420-056-A

A. Installation of the Auxiliary Lavatory Light

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Install the auxiliary lavatory light (3) to the lavatory structure
with the washers (2) and the screws (1).

(4) Connect the electrical connections (4) with the insertion/removal


tool M15.570-22 to the auxiliary lavatory light (3).

(5) Install the lavatory ventilation flexible-hose (1) with the clamp
(2).

R **ON A/C 001-012, 014-099,

Subtask 33-51-14-861-053

B. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).


R

EFF :

001-012, 014-099,  33-51-14

Page 427
May 01/06
 
IAC 
Subtask 33-51-14-865-057

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
79WL.

Subtask 33-51-14-710-058

D. Test

(1) Make sure that the auxiliary lavatory light 83WL comes on when you
close the circuit breaker.

(2) Do the operational test of the lavatory air-extraction airflow


(Ref. TASK 26-17-00-750-002).

5. Close-up
________

Subtask 33-51-14-410-054

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Close the access panel 261AC.

(3) Remove the stepladder.

Subtask 33-51-14-862-050

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).


R

EFF :

001-012, 014-099,  33-51-14

Page 428
May 01/06
 
IAC 
**ON A/C 101-199, 901-999,

TASK 33-51-14-000-006

Removal of the Auxiliary/Mirror Lavatory Light

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R **ON A/C 101-199,

R 33-51-14-991-006-A Fig. 404

R **ON A/C 901-999,

R 33-51-14-991-006 Fig. 404A



EFF :

101-199, 901-999,  33-51-14

Page 429
May 01/07
 
IAC 
**ON A/C 101-199, 901-999,

3. __________
Job Set-up

Subtask 33-51-14-865-064

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 79WL H07
2000VU LAV FWD/OCCUPIED 1WJ F01
2001VU LAVATORY AFT/OCCUPIED 11WJ B04

4. Procedure
_________

**ON A/C 101-199,

(Ref. Fig. 404/TASK 33-51-14-991-006-A)

**ON A/C 901-999,

(Ref. Fig. 404A/TASK 33-51-14-991-006)

**ON A/C 101-199, 901-999,

Subtask 33-51-14-020-058

A. Removal of the Auxiliary/Mirror Lavatory Light (LED)

(1) Push the locking catches (2) of the auxiliary/mirror light housing
(3) to remove the auxiliary/mirror light housing (3).

(2) Identify the electrical connectors (1) before you disconnect them.



EFF :

101-199, 901-999,  33-51-14

Page 430
Aug 01/07
 
IAC 
R Auxiliary/Mirror Lavatory Light
R Figure 404/TASK 33-51-14-991-006-A


R

EFF :

101-199,  33-51-14

Page 431
May 01/07
 
IAC 
Auxiliary/Mirror Lavatory Light
R Figure 404A/TASK 33-51-14-991-006


R

EFF :

901-999,  33-51-14

Page 432
May 01/07
 
IAC 
(3) Disconnect the electrical connectors (1) from the auxiliary/mirror
light housing (3).



EFF :

101-199, 901-999,  33-51-14

Page 433
May 01/07
R  
IAC 
TASK 33-51-14-400-006

Installation of the Auxiliary/Mirror Lavatory Light

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

R **ON A/C 101-199,

R 33-51-14-991-006-A Fig. 404

R **ON A/C 901-999,

R 33-51-14-991-006 Fig. 404A



EFF :

101-199, 901-999,  33-51-14

Page 434
May 01/07
 
IAC 
**ON A/C 101-199, 901-999,

3. __________
Job Set-up

Subtask 33-51-14-865-071

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 79WL H07
2000VU LAV FWD/OCCUPIED 1WJ F01
2001VU LAVATORY AFT/OCCUPIED 11WJ B04

4. Procedure
_________

**ON A/C 101-199,

(Ref. Fig. 404/TASK 33-51-14-991-006-A)

**ON A/C 901-999,

(Ref. Fig. 404A/TASK 33-51-14-991-006)

**ON A/C 101-199, 901-999,

Subtask 33-51-14-420-058

A. Installation of the Auxiliary/Mirror Lavatory Light (LED)

(1) Clean the component interface and/or the adjacent area.

(2) Do an inspection of the component interface and/or the adjacent area.

(3) Make sure that the electrical connectors are clean and in the correct
condition.



EFF :

101-199, 901-999,  33-51-14

Page 435
Aug 01/07
 
IAC 
(4) Connect the electrical connectors (1) as identified during the
removal procedure to the auxiliary/mirror light housing (3).

(5) Install the auxiliary/mirror light housing (3) to the lavatory


structure.

NOTE : Make sure that you hear a click when the catches (2) lock in
____
position.

Subtask 33-51-14-861-059

B. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-51-14-865-065

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s): 79WL, 1WJ, 11WJ.

Subtask 33-51-14-710-060

D. Test

(1) Make sure that the auxiliary lavatory light comes on when you close
the circuit breaker 79WL.

(2) Make sure that the mirror lavatory light comes on when you close and
lock the lavatory door.
R

5. Close-up
________

Subtask 33-51-14-860-053

A. Put the aircraft back to the serviceable condition.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Close the lavatory door.

(3) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

101-199, 901-999,  33-51-14

Page 436
Aug 01/07
 
IAC 
LIGHT - EMERGENCY, OVERWING (60WL,61WL,62WL,63WL) - REMOVAL/INSTALLATION
________________________________________________________________________

TASK 33-51-15-000-001

Removal of the Emergency Overwing Lights 60WL (61WL, 62WL, 63WL)

WARNING : ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE
_______
ENVIRONMENT.

WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.

NOTE : The procedure is the same for all emergency overwing lights 60 WL (61WL,
____
62WL, 63WL).

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific access platform 3.5 m (11 ft. 6 in.)
FOR FIN 61WL, 63WL
No specific wing mats

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-51-15-991-001 Fig. 401


R

EFF :

001-012, 014-099, 901-999,  33-51-15

Page 401
Feb 01/07
 
IAC 
3. __________
Job Set-up

Subtask 33-51-15-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05
122VU LIGHTING/CABIN/EMER/LT 3WL V07

R **ON A/C 001-012, 014-099,

Subtask 33-51-15-860-050

B. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.

R **ON A/C 901-999,

R Subtask 33-51-15-860-050-A

R B. Aircraft Maintenance Configuration

R (1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
R 4WL is in the OFF position.

R (2) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
R button and its light are off.



EFF :

001-012, 014-099, 901-999,  33-51-15

Page 402
Aug 01/07
 
IAC 
R **ON A/C 001-012, 014-099, 901-999,

Subtask 33-51-15-010-051

C. Get Access

(1) Put the access platform in position:


FOR 60WL, 62WL
at Zone 844,
FOR 61WL, 63WL
at Zone 834.

(2) Put the wing mats in position at the respective emergency overwing
light.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-51-15-991-001)

Subtask 33-51-15-020-050

A. Removal of the Emergency Overwing Light

(1) Removal of the Emergency Overwing-Light Assembly

(a) Remove the screws (4).

(b) Remove the emergency overwing-light assembly sufficient to get


access to the electrical connector (1) and the bonding strap (3).

(c) Support the emergency overwing-light assembly and disconnect the


electrical connector (1).

(d) Remove the screw (2) and disconnect the bonding strap (3).

(e) Put blanking caps on the disconnected electrical connectors.

(f) Remove the emergency overwing-light assembly.

(2) Removal of the Bulb(s) of the Emergency Overwing Light

(a) Remove the screws (5).

(b) Remove the lens (6) and the sealing (7) from the light housing
(10).



EFF :

001-012, 014-099, 901-999,  33-51-15

Page 403
Aug 01/07
 
IAC 
Emergency Overwing Light 60WL/61WL/62WL/63WL
Figure 401/TASK 33-51-15-991-001


R

EFF :

001-012, 014-099, 901-999,  33-51-15

Page 404
Feb 01/07
 
IAC 
(3) Remove the lens diffuser (8).

(4) Remove the bulb(s) (9).



EFF :

001-012, 014-099, 901-999,  33-51-15

Page 405
Aug 01/07
R  
IAC 
TASK 33-51-15-400-001

Installation of the Emergency Overwing Lights 60WL (61WL, 62WL, 63WL)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

20-28-00-912-004 Electrical Bonding of Components With Conductive


Bolts and Screws and Bonding Straps in the Fuselage
and in the Wings (this does not include the tanks)-
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
33-51-15-991-001 Fig. 401

3. __________
Job Set-up

R **ON A/C 001-012, 014-099,

Subtask 33-51-15-860-052

A. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.



EFF :

001-012, 014-099, 901-999,  33-51-15

Page 406
Aug 01/07
 
IAC 
R **ON A/C 901-999,

R Subtask 33-51-15-860-052-A

R A. Aircraft Maintenance Configuration

R (1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
R 4WL is in the OFF position.

R (2) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
R button and its light are off.

R **ON A/C 001-012, 014-099, 901-999,

Subtask 33-51-15-865-054

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05
122VU LIGHTING/CABIN/EMER/LT 3WL V07

4. Procedure
_________

(Ref. Fig. 401/TASK 33-51-15-991-001)

Subtask 33-51-15-910-050

A. Preparation for Installation

(1) Make sure that the parts retained from the removed component are
clean and in the correct condition.

(2) Clean the component interface and/or the adjacent area.

(3) Do an inspection of the component interface and/or the adjacent area.



EFF :

001-012, 014-099, 901-999,  33-51-15

Page 407
Aug 01/07
 
IAC 
Subtask 33-51-15-420-050

B. Installation of the Emergency Overwing Light

(1) Installation of the Emergency Overwing-Light Assembly

(a) Remove the blanking caps from the electrical connectors.

(b) Make sure that the electrical connectors are clean and in the
correct condition.

(c) Connect the electrical connector (1).

(d) Install the bonding strap (3) with the screw (2) (Ref. TASK 20-
28-00-912-004).

(e) Make sure that the work area is clean and clear of tool(s) and
other items.

(f) Put the emergency overwing-light assembly into position in the


fuselage structure.

(g) Install the screws (4).

(2) Installation of the Bulb(s) of the Emergency Overwing Light

(a) Install the bulb(s) (9) in the light housing (10).

(b) Install the lens diffuser in the light housing (10).

(c) Install the lens (6) and the sealing (7) with the screws (5) to
the light housing (10).

Subtask 33-51-15-865-051

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1WL, 2WL, 3WL.



EFF :

001-012, 014-099, 901-999,  33-51-15

Page 408
Aug 01/07
R  
IAC 
Subtask 33-51-15-860-051

D. Preparation for the Test

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED
_______
BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

Subtask 33-51-15-710-053

E. Do this test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. At the emergency exits: At the emergency exits:

- pull down and remove the cover - the SLIDE ARMED light on the cabin
flap from one of the related lining comes on,
hatches,

- push the latch pin against the - the SLIDE ARMED light goes off,
spring and turn it a quarter
turn counterclockwise to
retract it to the DISARMED
position.

On the overwing fuselage:

- the related emergency overwing lights


come on.

2. At the emergency exits: At the emergency exits:

- push the latch pin against the - the SLIDE ARMED light comes on.
spring and turn it a quarter
turn clockwise to extend it to
the ARMED position.

On the overwing fuselage:

- the related emergency overwing lights


go off.



EFF :

001-012, 014-099, 901-999,  33-51-15

Page 409
Aug 01/07
R  
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
3. At the emergency exits: At the emergency exits:

- install and close the removed - the SLIDE ARMED light goes off.
cover flap on the related
hatch.

5. Close-up
________

Subtask 33-51-15-410-053

A. Close Access

(1) Remove the wing mats.

(2) Remove the access platform(s).

Subtask 33-51-15-862-052

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

001-012, 014-099, 901-999,  33-51-15

Page 410
Aug 01/07
 
IAC 
SIGN - EMERGENCY EXIT (40WL,41WL,42WL,43WL,44WL,45WL) - REMOVAL/INSTALLATION
____________________________________________________________________________

TASK 33-51-16-000-001

Removal of the Emergency Exit Sign

NOTE : The procedure is the same for all emergency exit signs.
____

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific stepladder 1.0 m (3 ft. 3 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

R **ON A/C 001-012, 014-099, 101-199,

33-51-16-991-001 Fig. 401

R **ON A/C 901-999,

33-51-16-991-001-A Fig. 401A



EFF :

ALL  33-51-16

Page 401
Feb 01/07
 
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-51-16-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05

R **ON A/C 001-012, 014-099,

Subtask 33-51-16-860-050

B. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position

(3) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.

(4) Put the stepladder in position:

FOR 40WL, 41WL


in Zone 222 or in Zone 221,

FOR 42WL, 43WL


in Zone 242 or in Zone 241,

FOR 44WL, 45WL


in Zone 262 or in Zone 261.



EFF :

ALL  33-51-16

Page 402
Aug 01/07
 
IAC 
**ON A/C 101-199,

Subtask 33-51-16-860-050-B

B. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
pushbutton and its internal light are off.

(4) Put the stepladder in position:

FOR 40WL, 41WL


in Zone 222 or in Zone 221,

FOR 42WL, 43WL


in Zone 252 or in Zone 251,

FOR 44WL, 45WL


in Zone 262 or in Zone 261,

FOR 46WL, 47WL


in Zone 232 or in Zone 231.

R **ON A/C 901-999,

R Subtask 33-51-16-860-050-C

R B. Aircraft Maintenance Configuration

R (1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
R 4WL is in the OFF position.

R (2) On the overhead panel 25VU, make sure that the NO SMOKING switch
R 190RH is in the OFF position

R (3) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
R pushbutton and its internal light are off.


R

EFF :

101-199, 901-999,  33-51-16

Page 403
Aug 01/07
 
IAC 
R (4) Put the stepladder in position:
R
R FOR 40WL, 41WL
R in Zone 222 or in Zone 221
R
R FOR 42WL, 43WL
R in Zone 242 or in Zone 241
R
R FOR 44WL, 45WL
R in Zone 262 or in Zone 261.

**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099, 101-199,

(Ref. Fig. 401/TASK 33-51-16-991-001)

**ON A/C 901-999,

(Ref. Fig. 401A/TASK 33-51-16-991-001-A)

**ON A/C 001-012, 014-099, 901-999,

Subtask 33-51-16-020-050

A. Removal of the Emergency Exit Sign

(1) Remove the emergency exit sign-lens (2).

(2) Remove the screws (3) and the washers (4).

(3) Remove the emergency exit sign (1) sufficiently to get access to the
electrical connectors (5).

(4) Disconnect the electrical connectors (5).

(5) Put blanking caps on the disconnected electrical connectors.

(6) Remove the emergency exit sign (1).


R

EFF :

ALL  33-51-16

Page 404
Aug 01/07
 
IAC 
Emergency Exit Sign
Figure 401/TASK 33-51-16-991-001


R

EFF :

001-012, 014-099, 101-199,  33-51-16

Page 405
Aug 01/07
 
IAC 
Emergency Exit Sign
Figure 401A/TASK 33-51-16-991-001-A


R

EFF :

901-999,  33-51-16

Page 406
Aug 01/07
 
IAC 
**ON A/C 101-199,

Subtask 33-51-16-020-050-A

A. Removal of the Emergency Exit Sign

(1) Remove the lenses (1), (6) from the housings (4), (9).

(2) Remove the screws (2), (7) and the washers (3), (8).

(3) Disconnect the electrical connectors (5), (10).

(4) Put blanking caps on the disconnected electrical connectors.

(5) Remove the housings (4), (9).


R

EFF :

101-199,  33-51-16

Page 407
Aug 01/07
 
IAC 
**ON A/C ALL

TASK 33-51-16-400-001

Installation of the Emergency Exit Sign

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

**ON A/C 001-012, 014-099, 101-199,

33-51-16-991-001 Fig. 401

**ON A/C 901-999,

33-51-16-991-001-A Fig. 401A



EFF :

ALL  33-51-16

Page 408
Aug 01/07
R  
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-51-16-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05

R **ON A/C 001-012, 014-099,

Subtask 33-51-16-860-053

B. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.

(4) Make sure that the stepladder is in the correct position.

R **ON A/C 101-199, 901-999,

Subtask 33-51-16-860-053-A

B. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.



EFF :

ALL  33-51-16

Page 409
Aug 01/07
 
IAC 
(3) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
pushbutton and its internal light are off.

(4) Make sure that the stepladder is in the correct position.

**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099, 101-199,

(Ref. Fig. 401/TASK 33-51-16-991-001)

**ON A/C 901-999,

(Ref. Fig. 401A/TASK 33-51-16-991-001-A)

**ON A/C ALL

Subtask 33-51-16-910-056

A. Preparation for Installation

(1) Make sure that the parts retained from the removed component are
clean and in the correct condition.

(2) Clean the component interface and/or the adjacent area.

(3) Do an inspection of the component interface and/or the adjacent area.

**ON A/C 001-012, 014-099, 901-999,

Subtask 33-51-16-420-050

B. Installation of the Emergency Exit Sign

(1) Remove the blanking caps from the electrical connectors.

(2) Make sure that the electrical connectors are clean and in the correct
condition.

(3) Connect the electrical connectors (5).



EFF :

ALL  33-51-16

Page 410
Aug 01/07
R  
IAC 
(4) Install the emergency exit sign (1) with the washers (4) and the
screws (3) on the fuselage structure.

(5) Install the emergency exit sign-lens (2).

**ON A/C 101-199,

Subtask 33-51-16-420-050-A

B. Installation of the Emergency Exit Sign

(1) Remove the blanking caps from the electrical connectors.

(2) Make sure that the electrical connectors are clean and in the correct
condition.

(3) Connect the electrical connectors (5), (10).

(4) Put the housings (4), (9) in position.

(5) Install the screws (2), (7) and the washers (3), (8).

(6) Install the lenses (1), (6).

**ON A/C ALL

Subtask 33-51-16-865-053

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1WL, 2WL

Subtask 33-51-16-860-051

D. Preparation for the Test

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED
_______
BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.



EFF :

ALL  33-51-16

Page 411
Aug 01/07
R  
IAC 
(3) On the overhead panel 25VU, make sure that the EMER EXIT LT OFF
annunciator light 5WL is on.

Subtask 33-51-16-710-051

E. Do this operational test

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

On the overhead panel 25VU: On the related emergency exit sign:

- set the EMER EXIT LT switch 4WL to - the related emergency exit sign comes
the ON position. on.
On the overhead panel 25VU:
- the EMER EXIT LT OFF annunciator
light 5WL goes off.

On the overhead panel 25VU: On the related emergency exit sign:

- set the EMER EXIT LT switch 4WL to - the related emergency exit sign goes
the OFF position. off.
On overhead panel 25VU:
- the EMER EXIT LT OFF annunciator
light 5WL comes on.

5. Close-up
________

Subtask 33-51-16-860-052

A. Put the aircraft back to the serviceable condition.

(1) Make sure that the work area is clean and clear of tools and other
items.

(2) Remove the stepladder.

(3) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-51-16

Page 412
Aug 01/07
 
IAC 
SIGN - EMERGENCY EXIT LOCATION (50WL,51WL,52WL,53WL) - REMOVAL/INSTALLATION
___________________________________________________________________________

TASK 33-51-17-000-001

Removal of the Emergency Exit Location-Sign

WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.

NOTE : The procedure is the same for all emergency exit location-signs.
____

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific stepladder 1.0 m (3 ft. 3 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 001-012, 014-099,

33-51-17-991-001 Fig. 401

**ON A/C 101-199,

R 33-51-17-991-001-B Fig. 401A



EFF :

ALL  33-51-17

Page 401
Feb 01/07
 
IAC 
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 901-999,

33-51-17-991-001-A Fig. 401B

**ON A/C ALL

3. __________
Job Set-up

Subtask 33-51-17-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05

R **ON A/C 001-012, 014-099,

Subtask 33-51-17-860-050

B. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.

(4) Put the stepladder in position at the applicable zone.



EFF :

ALL  33-51-17

Page 402
Aug 01/07
 
IAC 
R **ON A/C 101-199, 901-999,

Subtask 33-51-17-860-050-A

B. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
pushbutton and its internal light are off.

(4) Put the stepladder in position at the applicable zone.

**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-51-17-991-001)

**ON A/C 101-199,

(Ref. Fig. 401A/TASK 33-51-17-991-001-B)

**ON A/C 901-999,

(Ref. Fig. 401B/TASK 33-51-17-991-001-A)



EFF :

ALL  33-51-17

Page 403
Aug 01/07
 
IAC 
Emergency Exit Location Sign
Figure 401/TASK 33-51-17-991-001


R

EFF :

001-012, 014-099,  33-51-17

Page 404
May 01/07
 
IAC 
R Emergency Exit Location Sign
R Figure 401A/TASK 33-51-17-991-001-B


R

EFF :

101-199,  33-51-17

Page 405
Feb 01/07
 
IAC 
Emergency Exit Location Sign
R Figure 401B/TASK 33-51-17-991-001-A


R

EFF :

901-999,  33-51-17

Page 406
Feb 01/07
 
IAC 
**ON A/C ALL

Subtask 33-51-17-020-050

A. Removal of the Emergency Exit Location-Sign

(1) Remove the emergency exit location-sign lens (1).

(2) Remove the screws (2) and the washers (3).

(3) Lower the emergency exit location-sign (4) to get access to the
electrical connectors (5).

(4) Disconnect the electrical connectors (5).

(5) Put blanking caps on the disconnected electrical connectors.

(6) Remove the emergency exit location-sign (4).



EFF :

ALL  33-51-17

Page 407
May 01/07
R  
IAC 
TASK 33-51-17-400-001

Installation of the Emergency Exit Location-Sign

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power

**ON A/C 001-012, 014-099,

33-51-17-991-001 Fig. 401

**ON A/C 101-199,

33-51-17-991-001-B Fig. 401A

**ON A/C 901-999,

33-51-17-991-001-A Fig. 401B



EFF :

ALL  33-51-17

Page 408
May 01/07
R  
IAC 
**ON A/C ALL

3. __________
Job Set-up

Subtask 33-51-17-865-051

A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05

R **ON A/C 001-012, 014-099,

Subtask 33-51-17-860-053

B. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.

(4) Make sure that the stepladder is in position.

R **ON A/C 101-199, 901-999,

Subtask 33-51-17-860-053-A

B. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.



EFF :

ALL  33-51-17

Page 409
Aug 01/07
 
IAC 
R (3) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
R pushbutton and its internal light are off.

R (4) Make sure that the stepladder is in position.

R **ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-51-17-991-001)

**ON A/C 101-199,

(Ref. Fig. 401A/TASK 33-51-17-991-001-B)

**ON A/C 901-999,

(Ref. Fig. 401B/TASK 33-51-17-991-001-A)

**ON A/C ALL

Subtask 33-51-17-910-051

A. Preparation for Installation

(1) Make sure that the parts retained from the removed component are
clean and in the correct condition.

(2) Clean the component interface and/or the adjacent area.

(3) Do an inspection of the component interface and/or the adjacent area.

Subtask 33-51-17-420-050

B. Installation of the Emergency Exit Location-Sign

(1) Remove the blanking caps from the electrical connectors.

(2) Make sure that the electrical connectors are clean and in the correct
condition.



EFF :

ALL  33-51-17

Page 410
May 01/07
 
IAC 
(3) Connect the electrical connectors (5).

(4) Install the emergency exit location-sign (4) to the fuselage


structure with the washers (3) and the screws (2).

(5) Install the emergency-exit location-sign lens (1).

Subtask 33-51-17-865-053

C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):
1WL, 2WL.

Subtask 33-51-17-860-051

D. Preparation for the Test

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the overhead panel 25VU, make sure that the EMER EXIT LT OFF
annunciator light 5WL is on.

Subtask 33-51-17-710-051

E. Do this operational test.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the overhead panel 25VU: On the related emergency exit location


sign:
- set the EMER EXIT LT switch 4WL - the related emergency exit location
to the ON position. sign comes on.

On the overhead panel 25VU:


- the EMER EXIT LT OFF annunciator
light 5WL goes off.

2. On the overhead panel 25VU: On the related emergency exit location


sign:
- set the EMER EXIT LT switch 4WL - the related emergency exit location
to the OFF position. sign goes off.



EFF :

ALL  33-51-17

Page 411
May 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
On the overhead panel 25VU:
- the EMER EXIT LT OFF annunciator
light 5WL comes on.

5. Close-up
________

Subtask 33-51-17-860-052

A. Put the aircraft back to the serviceable condition.

(1) Remove the stepladder.

(2) Make sure that the work area is clean and clear of tool(s) and other
items.

(3) De-energize the aircraft electrical circuits. (Ref. TASK 24-41-00-


862-002)



EFF :

ALL  33-51-17

Page 412
May 01/07
 
IAC 
LIGHT - EMERGENCY EXIT LOCATION, SEAT/WALL MOUNTED - REMOVAL/INSTALLATION
_________________________________________________________________________

TASK 33-51-18-000-001

Removal of the Seat/Wall-Mounted Emergency-Exit Location-Light

WARNING : ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE
_______
ENVIRONMENT.

CAUTION : DO NOT DISCONNECT THE CONNECTOR DURING OPERATION. ARCING CAN DAMAGE
_______
THE CONTACT PINS.

NOTE : The procedure is the same for all the seat/wall-mounted emergency-exit
____
location-lights.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-51-18-991-001 Fig. 401


R

EFF :

001-012, 014-099,  33-51-18

Page 401
May 01/06
 
IAC 
3. __________
Job Set-up

Subtask 33-51-18-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05

Subtask 33-51-18-860-050

B. Aircraft Maintenance Configuration

(1) Make sure that the EMER EXIT LT switch 4WL on the overhead panel 25VU
is in the OFF position

(2) Make sure that the LIGHT EMER pushbutton switch and its integral
light on the forward attendant panel 120RH are off.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-51-18-991-001)

Subtask 33-51-18-020-050

A. Removal of the Seat-Mounted Emergency-Exit Location-Light (AIRSIGNA)

(1) Removal of the Light Assembly

(a) Carefully remove the lens (4) from the light housing (2).

(b) Release the two attachment clips (1) and remove the light housing
(2) from the passenger seat.

(c) Support the light housing (2) and disconnect the electrical
connectors (5).

(d) Remove the light housing (2).

(2) Removal of the Bulb(s) of the Light

(a) Carefully remove the lens (4) from the light housing (2).

(b) Remove the bulb(s) (3).


R

EFF :

001-012, 014-099,  33-51-18

Page 402
May 01/06
 
IAC 
Seat-Mounted Emergency-Exit Location-Light
Figure 401/TASK 33-51-18-991-001


R

EFF :

001-012, 014-099,  33-51-18

Page 403
May 01/06
 
IAC 
TASK 33-51-18-400-001

Installation of the Seat/Wall-Mounted Emergency-Exit Location-Light

NOTE : The procedure is the same for all the seat/wall-mounted emergency-exit
____
location- lights.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
33-51-00-710-001 Operational Test of Emergency Lights by TEST EMER
LIGHT SYS Pushbutton
33-51-18-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-51-18-860-053

A. Aircraft Maintenance Configuration

(1) Make sure that the EMER EXIT LT switch 4WL on the overhead panel 25VU
is in the OFF position.

(2) Make sure that the LIGHT EMER pushbutton switch and its integral
light on the forward attendant panel 120RH are off.


R

EFF :

001-012, 014-099,  33-51-18

Page 404
May 01/06
 
IAC 
Subtask 33-51-18-865-051

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05

4. Procedure
_________

(Ref. Fig. 401/TASK 33-51-18-991-001)

Subtask 33-51-18-910-050

A. Preparation for Installation

(1) Make sure that the parts retained from the removed component are
clean and in the correct condition.

(2) Clean the component interface and/or the adjacent area.

(3) Do an inspection of the component interface and/or the adjacent area.

Subtask 33-51-18-420-050

B. Installation of the Seat-Mounted Emergency-Exit Location-Light (AIRSIGNA)

(1) Installation of the Light Assembly

(a) Make sure that the electrical connectors are clean and in the
correct condition.

(b) Connect the electrical connectors (5) to the light housing (2).

(c) Install the light housing (2) with the reflectors at the top to
the passenger seat.
Make sure that you hear a click when the light housing (2) locks
in position.

(d) Install the lens (4) with the red stripe at the top to the light
housing (2).
Make sure that you hear a click when the lens (4) locks in
position.


R

EFF :

001-012, 014-099,  33-51-18

Page 405
May 01/06
 
IAC 
(2) Installation of the Bulb(s) of the Light

(a) Install the bulb(s) (3) in the light housing (2).

(b) Install the lens (4) with the red stripe at the top to the light
housing (2).
Make sure that you hear a click when the lens (4) locks in
position.

Subtask 33-51-18-861-050

C. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-51-18-710-050

D. Do the operational test of the cabin emergency lighting (Ref. TASK 33-51-
00-710-001).

5. Close-up
________

Subtask 33-51-18-860-052

A. Put the aircraft back to the serviceable condition.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).


R

EFF :

001-012, 014-099,  33-51-18

Page 406
May 01/06
 
IAC 
LIGHT - EMERGENCY, SEAT/WALL MOUNTED - REMOVAL/INSTALLATION
___________________________________________________________

TASK 33-51-19-000-001

Removal of the Seat/Wall-Mounted Emergency Light

WARNING : ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE
_______
ENVIRONMENT.

CAUTION : DO NOT DISCONNECT THE CONNECTOR DURING OPERATION. ARCING CAN DAMAGE
_______
THE CONTACT PINS.

NOTE : The procedure is the same for all the seat/wall-mounted emergency
____
lights.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific welded plastic bag

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-51-19-991-001 Fig. 401


R

EFF :

001-012, 014-099,  33-51-19

Page 401
May 01/06
 
IAC 
3. __________
Job Set-up

Subtask 33-51-19-865-050

A. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05

Subtask 33-51-19-860-050

B. Aircraft Maintenance Configuration

(1) Make sure that the EMER EXIT LT switch 4WL on the overhead panel 25VU
is in the OFF position

(2) Make sure that the LIGHT EMER pushbutton switch and its integral
light on the forward attendant panel 120RH are off.

4. Procedure
_________

(Ref. Fig. 401/TASK 33-51-19-991-001)

Subtask 33-51-19-020-050

A. Removal of the Seat-Mounted Emergency Light

(1) Carefully remove the lens (4) from the housing (2).

(2) Release the two attach/detach clips (1) and remove the housing (2)
from the passenger seat.

(3) Support the housing (2) and disconnect the electrical connectors (5).

(4) Remove the housing (2) and keep it together with the lens (4) in a
welded plastic bag.


R

EFF :

001-012, 014-099,  33-51-19

Page 402
May 01/06
 
IAC 
Seat-Mounted Emergency Light
Figure 401/TASK 33-51-19-991-001


R

EFF :

001-012, 014-099,  33-51-19

Page 403
May 01/06
 
IAC 
TASK 33-51-19-400-001

Installation of the Seat/Wall-Mounted Emergency Light

NOTE : The procedure is the same for all the seat/wall-mounted emergency
____
lights.

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
33-51-00-710-001 Operational Test of Emergency Lights by TEST EMER
LIGHT SYS Pushbutton
AIPC 33511901010
AIPC 33511901020
AIPC 33511901030
33-51-19-991-001 Fig. 401

3. __________
Job Set-up

Subtask 33-51-19-860-054

A. Aircraft Maintenance Configuration

(1) Make sure that the EMER EXIT LT switch 4WL on the overhead panel 25VU
is in the OFF position.

(2) Make sure that the LIGHT EMER pushbutton switch and its integral
light on the forward attendant panel 120RH are off.


R

EFF :

001-012, 014-099,  33-51-19

Page 404
May 01/06
 
IAC 
Subtask 33-51-19-865-051

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05

4. Procedure
_________

(Ref. Fig. 401/TASK 33-51-19-991-001)

Subtask 33-51-19-910-050

A. Preparation for Installation

(1) Make sure that the parts retained from the removed component are
clean and in the correct condition.

(2) Clean the component interface and/or the adjacent area.

(3) Do an inspection of the component interface and/or the adjacent area.

Subtask 33-51-19-420-050

B. Installation of the Seat-Mounted Emergency Light

(1) Connect the electrical connectors (5) to the housing (2) (Ref. AIPC
33511901030).

(2) Install the housing (2) with the reflectors at the top to the related
passenger seat.

NOTE : Make sure that you hear a click when the housing locks in
____
position.

(3) Replace the lamp (3) (Ref. AIPC 33511901020) if necessary.

(4) Install the lens (4) (Ref. AIPC 33511901010) to the housing (2).

NOTE : Make sure that you hear a click when the lens locks in
____
position.


R

EFF :

001-012, 014-099,  33-51-19

Page 405
May 01/06
 
IAC 
Subtask 33-51-19-861-050

C. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

Subtask 33-51-19-710-050

D. Do the operational test of the cabin emergency lighting (Ref. TASK 33-51-
00-710-001).

5. Close-up
________

Subtask 33-51-19-860-053

A. Put the aircraft back to the serviceable condition.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).


R

EFF :

001-012, 014-099,  33-51-19

Page 406
May 01/06
 
IAC 
______________________________________________________________________
PHOTOLUMINESCENT STRIP - FLOOR PROXIMITY EMERGENCY ESCAPE PATH MARKING
____________________
REMOVAL/INSTALLATION

TASK 33-51-21-000-001

Removal of the Photoluminescent Strip of the Floor-Proximity Emergency-Escape


Path-Marking

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific nonmetallic scraper

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-42-00-861-001 Energize the Ground Service Network from the External


Power

**ON A/C 101-199,

33-51-21-991-001-B Fig. 401

**ON A/C 901-901,

33-51-21-991-001-A Fig. 401A

**ON A/C 902-999,

R 33-51-21-991-001-C Fig. 401B



EFF :

101-199, 901-999,  33-51-21

Page 401
Aug 01/07
 
IAC 
**ON A/C 101-199, 901-999,

3. __________
Job Set-up

Subtask 33-51-21-860-050

A. Energize the ground service network


(Ref. TASK 24-42-00-861-001)

4. Procedure
_________

**ON A/C 101-199,

(Ref. Fig. 401/TASK 33-51-21-991-001-B)

**ON A/C 901-901,

(Ref. Fig. 401A/TASK 33-51-21-991-001-A)

**ON A/C 902-999,

R (Ref. Fig. 401B/TASK 33-51-21-991-001-C)

**ON A/C 101-199, 901-999,

Subtask 33-51-21-020-050

A. Removal of the Photoluminescent Strip of the Floor-Proximity


Emergency-Escape Path-Marking

(1) Remove the sealant (4) between the non textile floor covering and the
photoluminescent strip (1) with a nonmetallic scraper.

(2) Remove the photoluminescent strips (1) and (2) from the floor panels.
Use a nonmetallic scraper to help the removal procedure.

(3) Remove the filler (3) together with the photoluminescent strips (1)
and (2), if installed.



EFF :

101-199, 901-999,  33-51-21

Page 402
Aug 01/07
 
IAC 
INTENTIONALLY BLANK





 33-51-21

Page 403
Aug 01/06
 
IAC 
R Photoluminescent Strip (Floor Mounted)
R of the Floor-Proximity Emergency-Escape Path-Marking
R Figure 401/TASK 33-51-21-991-001-B12 (SHEET 1)



EFF :

101-199, 

33-51-21 Page 404
May 01/07
 
IAC 
R Photoluminescent Strip (Floor Mounted)
R of the Floor-Proximity Emergency-Escape Path-Marking
R Figure 401/TASK 33-51-21-991-001-B22 (SHEET 2)



EFF :

101-199, 

33-51-21 Page 405
May 01/07
 
IAC 
Photoluminescent Strips (Floor Mounted)
of the Floor-Proximity Emergency-Escape Path-Marking
Figure 401A/TASK 33-51-21-991-001-A12 (SHEET 1)



R EFF :

901-901, 

33-51-21 Page 406
May 01/07
 
IAC 
Photoluminescent Strips (Floor Mounted)
of the Floor-Proximity Emergency-Escape Path-Marking
Figure 401A/TASK 33-51-21-991-001-A22 (SHEET 2)



R EFF :

901-901, 

33-51-21 Page 407
May 01/07
 
IAC 
R Photoluminescent Strip (Floor-Mounted)
R of the Floor-Proximity Emergency-Escape Path-Marking
R Figure 401B/TASK 33-51-21-991-001-C12 (SHEET 1)



EFF :

902-999, 

33-51-21 Page 408
Aug 01/07
 
IAC 
R Photoluminescent Strip (Floor-Mounted)
R of the Floor-Proximity Emergency-Escape Path-Marking
R Figure 401B/TASK 33-51-21-991-001-C22 (SHEET 2)



EFF :

902-999, 

33-51-21 Page 409
Aug 01/07
 
IAC 
TASK 33-51-21-400-001

Installation of the Photoluminescent Strip of the Floor-Proximity


Emergency-Escape Path-Marking

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific nonmetallic scraper

B. Consumable Materials

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

Material No. 09-036


SILICONE SEALANT (1 PART) (Ref. 20-31-00)
Material No. 11-003 USA ASTM D 740
METHYL-ETHYL-KETONE (Ref. 20-31-00)

C. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-42-00-861-001 Energize the Ground Service Network from the External


Power
24-42-00-862-001 De-energize the Ground Service Network Supplied from
the External Power

**ON A/C 101-199,

R 33-51-21-991-001-B Fig. 401



EFF :

101-199, 901-999,  33-51-21

Page 410
May 01/07
 
IAC 
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

**ON A/C 901-901,

33-51-21-991-001-A Fig. 401A

**ON A/C 902-999,

R 33-51-21-991-001-C Fig. 401B

**ON A/C 101-199, 901-999,

3. __________
Job Set-up

Subtask 33-51-21-860-051

A. Make sure that the ground service network is energized (Ref. TASK 24-42-
00-861-001).

4. Procedure
_________

**ON A/C 101-199,

(Ref. Fig. 401/TASK 33-51-21-991-001-B)

**ON A/C 901-901,

(Ref. Fig. 401A/TASK 33-51-21-991-001-A)

**ON A/C 902-999,

R (Ref. Fig. 401B/TASK 33-51-21-991-001-C)



EFF :

101-199, 901-999,  33-51-21

Page 411
Aug 01/07
 
IAC 
**ON A/C 101-199, 901-999,

Subtask 33-51-21-910-050

A. Preparation for Installation

WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL


_______
MATERIALS ONLY WITH A GOOD SUPPLY OF AIR.
OBEY THE MANUFACTURERS INSTRUCTIONS.
PUT ON PROTECTIVE CLOTHING.
DO NOT GET THEM IN YOUR MOUTH.
DO NOT SMOKE.
DO NOT BREATHE THE GAS.
THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT.
GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.

(1) Remove the sealant (4) with a nonmetallic scraper.

(2) Clean the component interface and/or the adjacent area on the floor
panels with CLEANING AGENTS (Material No. 11-003).

(3) Do an inspection of the component interface and/or the adjacent area.

Subtask 33-51-21-420-050

B. Installation of the Photoluminescent Strips of the Floor-Proximity


Emergency-Escape Path-Marking

(1) Installation of the filler (3).

NOTE : The filler is only necessary for flush installation of the


____
photoluminescent strips with the floor covering.

(a) Between the ends of the filler (3) must be a distance of 2.0 mm
(0.0787 in.).

(b) Cut the filler (3) to the correct length.

(c) Remove the protective foil from the filler (3).

(d) Align the filler (3) and install it with a soft cotton cloth.

(2) Installation of the photoluminescent strips (1) and (2).

(a) Between the ends of the photoluminescent strips (1) and (2) must
be a distance of 2.0 mm (0.0787 in.).



EFF :

101-199, 901-999,  33-51-21

Page 412
Aug 01/07
R  
IAC 
(b) Cut the photoluminescent strips (1) and (2) to the correct
length.

(c) Remove the protective foil from the photoluminescent strips (1)
and (2).

(d) Align the photoluminescent strips (1) and (2) and install it with
a soft cotton cloth. Do the installation with light hand pressure
from one end of the photoluminescent strip (1) and (2) to the
other.

(e) Make sure that the photoluminescent strips (1) and (2) are
correctly installed.

(3) Apply SEALANTS (Material No. 09-036) (4) between the photoluminescent
strips (1) and (2) and the non-textile floor-covering.

5. Close-up
________

Subtask 33-51-21-860-052

A. De-energize the ground service network


(Ref. TASK 24-42-00-862-001)



EFF :

101-199, 901-999,  33-51-21

Page 413
Aug 01/07
R  
IAC 
TASK 33-51-21-920-002

Discard Photoluminescent Floor Path Marking System

1. __________________
Reason for the Job

R
R Self Explanatory

2. ______________________
Job Set-up Information

A. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

33-51-21-000-001 Removal of the Photoluminescent Strip of the


Floor-Proximity Emergency-Escape Path-Marking
33-51-21-400-001 Installation of the Photoluminescent Strip of the
Floor-Proximity Emergency-Escape Path-Marking

3. __________
Job Set-up

Subtask 33-51-21-941-050

A. There is no special job set-up for this task.

4. Procedure
_________

Subtask 33-51-21-020-051

A. Remove and discard the Strips of the Photoluminescent Floor Path Marking
System (Ref. TASK 33-51-21-000-001).

Subtask 33-51-21-420-051

B. Install the new Strips of the Photoluminescent Floor Path Marking System
(Ref. TASK 33-51-21-400-001).



EFF :

101-199, 901-999,  33-51-21

Page 414
Aug 01/07
 
IAC 
______________________________________________________________________
PHOTOLUMINESCENT STRIP - FLOOR PROXIMITY EMERGENCY ESCAPE PATH MARKING
_________________
CLEANING/PAINTING

TASK 33-51-21-100-001

Cleaning of the Photoluminescent Strips of the Floor-Proximity Emergency-Escape


Path-Marking

1. __________________
Reason for the Job

To make sure that the photoluminescent strips operate correctly.

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific lint-free cloth


No specific masking paper
No specific mild detergent

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-42-00-861-001 Energize the Ground Service Network from the External


Power
24-42-00-862-001 De-energize the Ground Service Network Supplied from
the External Power
33-51-21-991-003 Fig. 701

3. __________
Job Set-up

Subtask 33-51-21-860-053

A. Energize the ground service network


(Ref. TASK 24-42-00-861-001).


R

EFF :

101-199, 901-999,  33-51-21

Page 701
Feb 01/07
 
IAC 
4. Procedure
_________

Subtask 33-51-21-110-050

A. Cleaning of the Floor-Mounted Photoluminescent-Strips of the


Floor-Proximity Emergency-Escape Path-Marking
(Ref. Fig. 701/TASK 33-51-21-991-003)

R NOTE : The procedure to clean one photoluminescent strip is given. The


____
R procedure to clean the other photoluminescent strips is almost the
R same.

R (1) Attach the masking paper to each side of the photoluminescent strip
R (1), to protect the floor covering (2) from contamination.

(2) Use a lint-free cloth and a mixture of warm water and a mild
R detergent to remove the heavy contamination from the photoluminescent
R strip (1).
R

R (3) Make sure that you do not damage the floor covering (2).

R (4) Use a clean lint-free cloth and clean water to remove the remaining
contamination.

R (5) If necessary, do the cleaning procedure again, until the


R photoluminescent strip (1) is clean.

R (6) Use a clean lint-free cloth to dry and polish the photoluminescent
R strip (1).

R (7) Remove and discard the masking paper.

5. Close-up
________

Subtask 33-51-21-860-054

A. Put the aircraft back to the serviceable condition.

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

R (2) De-energize the ground service network


(Ref. TASK 24-42-00-862-001).


R

EFF :

101-199, 901-999,  33-51-21

Page 702
Feb 01/07
 
IAC 
Floor Mounted Photoluminescent-Strips
Figure 701/TASK 33-51-21-991-003


R

EFF :

101-199, 901-999,  33-51-21

Page 703
Feb 01/07
 
IAC 
POWER SUPPLY UNIT - EMERGENCY (10WL,11WL,12WL,13WL) - REMOVAL/INSTALLATION
__________________________________________________________________________

TASK 33-51-38-000-001

Removal of the Emergency Power-Supply Unit (EPSU)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific blanking caps


No specific circuit breaker(s) safety clip(s)
No specific stepladder 1.5 m (4 ft. 11 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

CMM 335107

**ON A/C 001-012, 014-099,

33-51-38-991-001 Fig. 401

**ON A/C 101-199,

R 33-51-38-991-001-B Fig. 401A

R **ON A/C 901-999,

R 33-51-38-991-001-A Fig. 401B


FOR FIN 10WL
25-23-42-000-001 Removal of the Ceiling Panels - Forward Utility Area
FOR FIN 13WL



EFF :

ALL  33-51-38

Page 401
Feb 01/07
 
IAC 
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

25-23-42-000-002 Removal of the Ceiling Panels - Aft Utility Area


25-23-45-000-003 Removal of the Door Frame Linings at the Left AFT
Passenger/Crew Door
35-21-41-000-001 Removal of the Emergency Oxygen Containers
FOR FIN 11WL
25-23-41-000-001 Removal of the Ceiling Panels
25-23-44-000-001 Removal of the Lower Sidewall-Panels (Dado Panels)
FOR FIN 12WL
25-23-41-000-001 Removal of the Ceiling Panels
25-23-44-000-001 Removal of the Lower Sidewall-Panels (Dado Panels)
FOR FIN 14WL
25-23-41-000-001 Removal of the Ceiling Panels
FOR FIN 15WL
25-23-41-000-001 Removal of the Ceiling Panels

**ON A/C ALL

3. __________
Job Set-up

R **ON A/C 001-012, 014-099,

Subtask 33-51-38-860-050

A. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.



EFF :

ALL  33-51-38

Page 402
Aug 01/07
 
IAC 
R **ON A/C 101-199, 901-999,

Subtask 33-51-38-860-050-A

A. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
pushbutton and its internal light are off.

**ON A/C ALL

Subtask 33-51-38-865-050

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05
122VU LIGHTING/CABIN/EMER/LT 3WL V07

**ON A/C 001-012, 014-099,

Subtask 33-51-38-010-050

C. Get Access

(1) Put the stepladder in position:


FOR 10WL
at the left FWD passenger/crew door,
FOR 13WL
at the left AFT passenger/crew door.



EFF :

ALL  33-51-38

Page 403
Aug 01/07
 
IAC 
(2) Remove the ceiling panel to get access to the the emergency
power-supply unit:
FOR 10WL
remove 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-42-
000-001).

(3) Remove the lower sidewall panel to get access to the emergency
power-supply unit:
FOR 11WL
remove 241KW at the left emergency exits (Ref. TASK 25-23-44-000-
001),
FOR 12WL
remove 242KW at the right emergency exits (Ref. TASK 25-23-44-000-
001).

(4) Remove the door frame lining to get access to the emergency
power-supply unit:
FOR 13WL
remove 261KW at the left AFT passenger/crew door (Ref. TASK 25-23-45-
000-003).

**ON A/C 101-199,

Subtask 33-51-38-010-050-B

C. Get Access

(1) Put the stepladder in position:


FOR 10WL
at the left FWD passenger/crew door,
FOR 11WL
between the rear emergency exit doors,
FOR 12WL
between the rear emergency exit doors,
FOR 13WL
between the AFT passenger/crew doors,
FOR 14WL
between the forward emergency exit doors,
FOR 15WL
between the forward emergency exit doors.

R (2) Remove the ceiling panel to get access to the emergency power-supply
R unit:
FOR 10WL
remove 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-42-
000-001),


R

EFF :

001-012, 014-099, 101-199,  33-51-38

Page 404
May 01/07
 
IAC 
FOR 11WL
remove 251KC between the rear emergency exit doors (Ref. TASK 25-23-
41-000-001),
FOR 12WL
remove 251KC between the rear emergency exit doors (Ref. TASK 25-23-
41-000-001),
FOR 14WL
remove 231JC between the forward emergency exit doors (Ref. TASK 25-
23-41-000-001),
FOR 15WL
remove 231JC between the forward emergency exit doors (Ref. TASK 25-
23-41-000-001),

(3) Lower one side of the emergency oxygen container and remove the
ceiling panel to get access to the emergency power-supply unit:
FOR 13WL
- disengage and lower one side of the emergency oxygen container 33WR
between the AFT passenger/crew doors (Ref. TASK 35-21-41-000-001),
R - do not disconnect the electrical connector of the emergency oxygen
R container.
- remove the ceiling panel 261CC at the left AFT passenger/crew door
(Ref. TASK 25-23-42-000-002).

**ON A/C 901-999,

Subtask 33-51-38-010-050-A

C. Get Access

(1) Put the stepladder in position:


FOR 10WL
at the left FWD passenger/crew door,
FOR 13WL
between the AFT passenger/crew doors.

R (2) Remove the ceiling panel to get access to the emergency power-supply
R unit:
FOR 10WL
remove 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-42-
000-001),

(3) Remove the lower sidewall panel to get access to the emergency
power-supply unit:
FOR 11WL
remove 241KW at the left emergency exit(s) (Ref. TASK 25-23-44-000-
001),


R

EFF :

101-199, 901-999,  33-51-38

Page 405
May 01/07
 
IAC 
FOR 12WL
remove 242KW at the right emergency exit(s) (Ref. TASK 25-23-44-000-
001).
FOR 13WL

(4) Open the ceiling filler-panel door adjacent to the ceiling panel
261CC at the left AFT passenger/crew door.

**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-51-38-991-001)

**ON A/C 101-199,

(Ref. Fig. 401A/TASK 33-51-38-991-001-B)

**ON A/C 901-999,

(Ref. Fig. 401B/TASK 33-51-38-991-001-A)

**ON A/C ALL

Subtask 33-51-38-020-051

A. Removal of the Emergency Power-Supply Unit (EPSU)

(1) Disconnect the electrical connector (2) from the emergency


power-supply unit (1).

(2) Put blanking caps on the disconnected electrical connectors.

(3) Remove the screws (3) and the washers (4) from the emergency
power-supply unit (1).

(4) Remove the emergency power-supply unit (1).

(5) Remove the screws (5) from the battery (6).


R

EFF :

ALL  33-51-38

Page 406
May 01/07
 
IAC 
Emergency Power-Supply Unit
Figure 401/TASK 33-51-38-991-001


R

EFF :

001-012, 014-099,  33-51-38

Page 407
May 01/07
 
IAC 
Emergency Power-Supply Unit
Figure 401A/TASK 33-51-38-991-001-B


R

EFF :

101-199,  33-51-38

Page 408
May 01/07
 
IAC 
Emergency Power-Supply Unit
R Figure 401B/TASK 33-51-38-991-001-A


R

EFF :

901-999,  33-51-38

Page 409
Feb 01/07
 
IAC 
(6) Carefully remove the battery (6) from the emergency power-supply unit
(1).

(7) Keep the battery (6) and/or the spare batteries under work shop
conditions connected to a constant power source (Ref. CMM 335107).



EFF :

ALL  33-51-38

Page 410
May 01/07
R  
IAC 
TASK 33-51-38-400-001

Installation of the Emergency Power-Supply Unit (EPSU)

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific stepladder 1.5 m (4 ft. 11 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
CMM 335107

**ON A/C 001-012, 014-099,

33-51-38-991-001 Fig. 401

**ON A/C 101-199,

33-51-38-991-001-B Fig. 401A

**ON A/C 901-999,

33-51-38-991-001-A Fig. 401B


FOR FIN 10WL
25-23-42-400-001 Installation of the Ceiling Panels - Forward Utility
Area



EFF :

ALL  33-51-38

Page 411
May 01/07
R  
IAC 
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

FOR FIN 11WL


25-23-41-400-001 Installation of the Ceiling Panels
25-23-44-400-001 Installation of the Lower Sidewall-Panels (Dado
Panels)
FOR FIN 12WL
25-23-41-400-001 Installation of the Ceiling Panels
25-23-44-400-001 Installation of the Lower Sidewall-Panels (Dado
Panels)
FOR FIN 13WL
25-23-42-400-002 Installation of the Ceiling Panels - Aft Utility Area
25-23-45-400-008 Installation of the Door Frame Linings at the Left
AFT Passenger/Crew Door
35-21-41-400-001 Installation of the Emergency Oxygen Containers
FOR FIN 14WL
25-23-41-400-001 Installation of the Ceiling Panels
FOR FIN 15WL
25-23-41-400-001 Installation of the Ceiling Panels

**ON A/C ALL

3. __________
Job Set-up

R **ON A/C 001-012, 014-099,

Subtask 33-51-38-860-053

A. Aircraft Maintenance Configuration

(1) Make sure that the stepladder is in position.

(2) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(3) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(4) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.



EFF :

ALL  33-51-38

Page 412
Aug 01/07
 
IAC 
**ON A/C 101-199,

Subtask 33-51-38-860-053-B

A. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
pushbutton and its internal light are off.

(4) Make sure that the stepladder is in position:


FOR 10WL
at the left forward passenger/crew door
FOR 11WL
between the rear emergency exit doors
FOR 12WL
between the rear emergency exit doors
FOR 13WL
between the aft passenger/crew doors
FOR 14WL
between the forward emergency exit doors
FOR 15WL
between the forward emergency exit doors.

R **ON A/C 901-999,

R Subtask 33-51-38-860-053-C

R A. Aircraft Maintenance Configuration

R (1) Make sure that the stepladder is in position.

R (2) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
R 4WL is in the OFF position.

R (3) On the overhead panel 25VU, make sure that the NO SMOKING switch
R 190RH is in the OFF position.

R (4) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
R pushbutton and its internal light are off.


R

EFF :

101-199, 901-999,  33-51-38

Page 413
Aug 01/07
 
IAC 
**ON A/C ALL

Subtask 33-51-38-865-051

B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05
122VU LIGHTING/CABIN/EMER/LT 3WL V07

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-51-38-991-001)

**ON A/C 101-199,

(Ref. Fig. 401A/TASK 33-51-38-991-001-B)

**ON A/C 901-999,

(Ref. Fig. 401B/TASK 33-51-38-991-001-A)

**ON A/C ALL

Subtask 33-51-38-420-050

A. Installation of the Emergency Power-Supply Unit (EPSU)

(1) Put the emergency power-supply unit (1) in position.

(2) Install the emergency power-supply unit (1) with the screws (3) and
the washers (4).

(3) Remove the blanking caps from the electrical connectors.



EFF :

ALL  33-51-38

Page 414
Aug 01/07
R  
IAC 
(4) Make sure that the electrical connectors are clean and in the correct
condition.

(5) Connect the electrical connector (2) to the emergency power-supply


unit (1).

NOTE : Make sure that the cable installed to the emergency


____
power-supply unit (1) has a drop loop in front of the
electrical connector.

Subtask 33-51-38-865-054

B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05
122VU LIGHTING/CABIN/EMER/LT 3WL V07

**ON A/C 001-012, 014-099, 901-999,

Subtask 33-51-38-860-052

C. Preparation for the Test

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

(2) If the emergency power-supply unit supplies overwing emergency


lights, make sure that these overwing emergency lights operate:

(a) Pull down and remove the cover flap from one of the related
hatches.

NOTE : The SLIDE ARMED light on the cabin lining at the emergency
____
exits comes on.

(b) Push the latch pin against the spring and turn it a quarter turn
counterclockwise to retract it to the DISARMED position.

NOTE : The SLIDE ARMED light goes off.


____

(c) Make sure that the overwing emergency lights come on.

(d) Push the latch pin against the spring and turn it a quarter turn
clockwise to extend it to the ARMED position.

NOTE : The SLIDE ARMED light comes on.


____



EFF :

ALL  33-51-38

Page 415
Aug 01/07
R  
IAC 
(e) Make sure that the overwing emergency lights go off.

(f) Install and close the removed cover flap on the related hatch.

NOTE : The SLIDE ARMED light goes off.


____

(3) On the overhead panel 25VU, set the EMER EXIT LT switch 4WL to the ON
position.

(4) Make sure also that all the other lights and signs of the emergency
lighting system connected to this emergency power-supply unit are
operate correctly.

(5) On the overhead panel 25VU, set the EMER EXIT LT switch 4WL to the
OFF position.

(6) Make sure that the battery is fully charged before you install it in
the power-supply unit (Ref. CMM 335107).

(7) Carefully put the battery (6) in the emergency power-supply unit (1)
and install the screws (5).

NOTE : To measure and keep the load values, the load programming
____
(TEACH IN) of the EPSU starts automatically when:
- the AC and the DC power are available
- on the FAP 120RH the LIGHT EMER pushbutton switch and its
integral light are off
- on the overhead panel 25VU the EMER EXIT LT switch 4WL is in
the OFF position
- on the overhead panel 25VU the NO SMOKING switch 190RH is in
the OFF position
- the overwing emergency lights are off
- the emergency power-supply unit is installed on the A/C for
the first time, or
the battery was removed for more than 5 s and is then
installed again.

**ON A/C 101-199,

Subtask 33-51-38-860-052-A

C. Preparation for the Test

(1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

(2) On the overhead panel 25VU, set the EMER EXIT LT switch 4WL to the ON
position.



EFF :

ALL  33-51-38

Page 416
Aug 01/07
R  
IAC 
(3) Make sure that all the lights and signs of the emergency lighting
system connected to this emergency power-supply unit are operate
correctly.

(4) On the overhead panel 25VU, set the EMER EXIT LT switch 4WL to the
OFF position.

(5) Make sure that the battery is fully charged before you install it in
the power-supply unit (Ref. CMM 335107).

(6) Carefully put the battery (6) in the emergency power-supply unit (1)
and install the screws (5).

NOTE : To measure and keep the load values, the load programming
____
(TEACH IN) of the EPSU starts automatically when:
- the AC and the DC power are available
- on the FAP 120RH the LIGHT EMER pushbutton switch and its
integral light are off
- on the overhead panel 25VU the EMER EXIT LT switch 4WL is in
the OFF position
- on the overhead panel 25VU the NO SMOKING switch 190RH is in
the OFF position
- the emergency power-supply unit is installed on the A/C for
the first time, or
the battery was removed for more than 5 s and is then
installed again.

**ON A/C 001-012, 014-099,

Subtask 33-51-38-740-050

D. Do this test.

NOTE : The test is the same for all emergency power-supply units.
____

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
**ON EPSU P/N 3214-5X

1. On the emergency power-supply On the emergency power-supply unit:


unit:
- push the TEST pushbutton for - the green LED
approx. 2 s. - BATTERY OK,
- INTERNAL LOADS OK,
- EXTERNAL LOADS OK


R

EFF :

001-012, 014-099, 101-199,  33-51-38

Page 417
May 01/07
 
IAC 
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
come on for approx. 1 min, if all
test loops are completed without
malfunction.
**ON EPSU P/N 3214-54-10

2. On the emergency power-supply On the emergency power-supply unit:


unit:
- push the TEST membrane switch - the green SYSTEM OK LED comes on for
for approximately 2 s. approximately 30 s if all test loops
are completed without malfunction.

**ON A/C 101-199, 901-999,

Subtask 33-51-38-740-050-A

D. Do this test.

NOTE : The test is the same for all emergency power-supply units.
____

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the emergency power-supply On the emergency power-supply unit:


unit:
- push the TEST membrane switch - the green SYSTEM OK LED comes on for
for approximately 2 s. approximately 30 s if all test loops
are completed without malfunction.



EFF :

ALL  33-51-38

Page 418
May 01/07
R  
IAC 
**ON A/C ALL

5. Close-up
________

**ON A/C 001-012, 014-099,

Subtask 33-51-38-410-052

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the ceiling panel:


FOR 10WL
install 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-
42-400-001).

(3) Install the lower sidewall panel:


FOR 11WL
install 241KW at the left emergency exits (Ref. TASK 25-23-44-400-
001),
FOR 12WL
install 242KW at the right emergency exits (Ref. TASK 25-23-44-400-
001).

(4) Install the door frame lining:


FOR 13WL
install 261KW at the left AFT passenger/crew door (Ref. TASK 25-23-
45-400-008).

(5) Remove the stepladder(s).


R

EFF :

ALL  33-51-38

Page 419
May 01/07
 
IAC 
**ON A/C 101-199,

Subtask 33-51-38-410-052-B

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the ceiling panel:


FOR 10WL
install 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-
42-400-001),
FOR 11WL
install 251KC between the rear emergency exit doors (Ref. TASK 25-23-
41-400-001),
FOR 12WL
install 251KC between the rear emergency exit doors (Ref. TASK 25-23-
41-400-001),
FOR 14WL
install 231JC between the forward emergency exit doors (Ref. TASK 25-
23-41-400-001),
FOR 15WL
install 231JC between the forward emergency exit doors (Ref. TASK 25-
23-41-400-001),

(3) Engage the emergency oxygen container and install the ceiling panel:
FOR 13WL
- lift and engage the emergency oxygen container 33WR between the AFT
passenger/crew doors (Ref. TASK 35-21-41-400-001),
- install the ceiling panel 261CC at the left AFT passenger/crew door
(Ref. TASK 25-23-42-400-002).

(4) Remove the stepladder(s).

**ON A/C 901-999,

Subtask 33-51-38-410-052-A

A. Close Access

(1) Install the ceiling panel:


FOR 10WL
install 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-
42-400-001).


R

EFF :

101-199, 901-999,  33-51-38

Page 420
May 01/07
 
IAC 
(2) Install the lower sidewall panel:
FOR 11WL
install 241KW at the left emergency exit(s) (Ref. TASK 25-23-44-400-
001),
FOR 12WL
install 242KW at the right emergency exit(s) (Ref. TASK 25-23-44-400-
001).
FOR 13WL

(3) Close the ceiling filler-panel adjacent to the ceiling panel 261CC at
the left AFT passenger/crew door.

(4) Remove the stepladder(s).

**ON A/C ALL

Subtask 33-51-38-862-051

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-51-38

Page 421
May 01/07
R  
IAC 
TASK 33-51-38-000-002

Removal of the Battery of the Emergency Power-Supply Unit

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific circuit breaker(s) safety clip(s)


No specific stepladder 1.5 m (4 ft. 11 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

CMM 335107

**ON A/C 001-012, 014-099,

33-51-38-991-001 Fig. 401

**ON A/C 101-199,

33-51-38-991-001-B Fig. 401A

**ON A/C 901-999,

33-51-38-991-001-A Fig. 401B


FOR FIN 10WL
25-23-42-000-001 Removal of the Ceiling Panels - Forward Utility Area
FOR FIN 13WL
25-23-45-000-003 Removal of the Door Frame Linings at the Left AFT
Passenger/Crew Door
35-21-41-000-001 Removal of the Emergency Oxygen Containers



EFF :

ALL  33-51-38

Page 422
May 01/07
R  
IAC 
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

FOR FIN 11WL


25-23-41-000-001 Removal of the Ceiling Panels
25-23-44-000-001 Removal of the Lower Sidewall-Panels (Dado Panels)
FOR FIN 12WL
25-23-41-000-001 Removal of the Ceiling Panels
25-23-44-000-001 Removal of the Lower Sidewall-Panels (Dado Panels)
FOR FIN 14WL
25-23-41-000-001 Removal of the Ceiling Panels
FOR FIN 15WL
25-23-41-000-001 Removal of the Ceiling Panels

**ON A/C ALL

3. __________
Job Set-up

R **ON A/C 001-012, 014-099,

Subtask 33-51-38-860-051

A. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.



EFF :

ALL  33-51-38

Page 423
Aug 01/07
 
IAC 
R **ON A/C 101-199, 901-999,

Subtask 33-51-38-860-051-A

A. Aircraft Maintenance Configuration

(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch
4WL is in the OFF position.

(2) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(3) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
pushbutton and its internal light are off.

**ON A/C ALL

Subtask 33-51-38-865-055

B. Open, safety and tag this(these) circuit breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05
122VU LIGHTING/CABIN/EMER/LT 3WL V07

**ON A/C 001-012, 014-099,

Subtask 33-51-38-010-051

C. Get Access

(1) Put the stepladder in position:


FOR 10WL
at the left FWD passenger/crew door,
FOR 13WL
at the left AFT passenger/crew doors.



EFF :

ALL  33-51-38

Page 424
Aug 01/07
 
IAC 
(2) Remove the ceiling panel to get access to the emergency power-supply
unit:
FOR 10WL
remove 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-42-
000-001).

(3) Remove the lower sidewall panel to get access to the emergency
power-supply unit:
FOR 11WL
remove 241KW at the left emergency exits (Ref. TASK 25-23-44-000-
001),
FOR 12WL
remove 242KW at the right emergency exits (Ref. TASK 25-23-44-000-
001).

(4) Remove the door frame lining to get access to the emergency
power-supply unit:
FOR 13WL
remove 261KW at the left AFT passenger/crew door (Ref. TASK 25-23-45-
000-003).

**ON A/C 101-199,

Subtask 33-51-38-010-051-B

C. Get Access

(1) Put the stepladder in position:


FOR 10WL
at the left FWD passenger/crew door,
FOR 11WL
between the rear emergency exit doors,
FOR 12WL
between the rear emergency exit doors,
FOR 13WL
between the AFT passenger/crew doors,
FOR 14WL
between the forward emergency exit doors,
FOR 15WL
between the forward emergency exit doors.

(2) Remove the ceiling panel to get access to the emergency power-supply
unit:
FOR 10WL
remove 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-42-
000-001),


R

EFF :

001-012, 014-099, 101-199,  33-51-38

Page 425
May 01/07
 
IAC 
FOR 11WL
remove 251KC between the rear emergency exit doors (Ref. TASK 25-23-
41-000-001),
FOR 12WL
remove 251KC between the rear emergency exit doors (Ref. TASK 25-23-
41-000-001),
FOR 14WL
remove 231JC between the forward emergency exit doors (Ref. TASK 25-
23-41-000-001),
FOR 15WL
remove 231JC between the forward emergency exit doors (Ref. TASK 25-
23-41-000-001),

(3) Lower one side of the emergency oxygen container to get access to the
emergency power-supply unit:
FOR 13WL
disengage and lower one side of the emergency oxygen container 33WR
R between the AFT passenger/crew doors (Ref. TASK 35-21-41-000-001),
R do not disconnect the electrical connector of the emergency oxygen
R container.

**ON A/C 901-999,

Subtask 33-51-38-010-051-A

C. Get Access

(1) Put the stepladder in position:


FOR 10WL
at the left FWD passenger/crew door,
FOR 13WL
between the AFT passenger/crew doors.

(2) Remove the ceiling panel to get access to the emergency power-supply
unit:
FOR 10WL
remove 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-42-
000-001).

(3) Remove the lower sidewall panel to get access to the emergency
power-supply unit:
FOR 11WL
remove 241KW at the left emergency exit(s) (Ref. TASK 25-23-44-000-
001),
FOR 12WL


R

EFF :

101-199, 901-999,  33-51-38

Page 426
May 01/07
 
IAC 
remove 242KW at the right emergency exit(s) (Ref. TASK 25-23-44-000-
001).

(4) Lower one side of the emergency oxygen container to get access to the
emergency power-supply unit:
FOR 13WL
disengage and lower one side of the emergency oxygen container 33WR
between the AFT passenger/crew doors (Ref. TASK 35-21-41-000-001).

NOTE : Do not disconnect the electrical connector of the emergency


____
oxygen container.

**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-51-38-991-001)

**ON A/C 101-199,

(Ref. Fig. 401A/TASK 33-51-38-991-001-B)

**ON A/C 901-999,

(Ref. Fig. 401B/TASK 33-51-38-991-001-A)

**ON A/C ALL

Subtask 33-51-38-020-053

A. Removal of the Battery of the Emergency Power-Supply Unit

(1) Remove the screws (5) from the battery (6).

(2) Carefully remove the battery (6) from the emergency power-supply unit
(1).

(3) Keep the battery (6) and/or the spare batteries under work shop
conditions connected to a constant power source (Ref. CMM 335107).



EFF :

ALL  33-51-38

Page 427
May 01/07
R  
IAC 
TASK 33-51-38-400-002

Installation of the Battery of the Emergency Power-Supply Unit

1. __________________
Reason for the Job

Self Explanatory

2. ______________________
Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------

No specific stepladder 1.5 m (4 ft. 11 in.)

B. Referenced Information

-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied


from the External Power
CMM 335107

**ON A/C 001-012, 014-099,

33-51-38-991-001 Fig. 401

**ON A/C 101-199,

33-51-38-991-001-B Fig. 401A

**ON A/C 901-999,

33-51-38-991-001-A Fig. 401B


FOR FIN 10WL
25-23-42-400-001 Installation of the Ceiling Panels - Forward Utility
Area
FOR FIN 13WL



EFF :

ALL  33-51-38

Page 428
May 01/07
R  
IAC 
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------

24-41-00-861-002 Energize the Aircraft Electrical Circuits from the


External Power
25-23-45-400-008 Installation of the Door Frame Linings at the Left
AFT Passenger/Crew Door
35-21-41-400-001 Installation of the Emergency Oxygen Containers
FOR FIN 11WL
25-23-41-400-001 Installation of the Ceiling Panels
25-23-44-400-001 Installation of the Lower Sidewall-Panels (Dado
Panels)
FOR FIN 12WL
25-23-41-400-001 Installation of the Ceiling Panels
25-23-44-400-001 Installation of the Lower Sidewall-Panels (Dado
Panels)
FOR FIN 14WL
25-23-41-400-001 Installation of the Ceiling Panels
FOR FIN 15WL
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
25-23-41-400-001 Installation of the Ceiling Panels

**ON A/C ALL

3. __________
Job Set-up

Subtask 33-51-38-865-056

A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
breaker(s):

-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU LIGHTING/EMER LT/CABIN 2WL H06
49VU LIGHTING/EMER LT/CABIN 1WL H05
122VU LIGHTING/CABIN/EMER/LT 3WL V07


R

EFF :

ALL  33-51-38

Page 429
May 01/07
 
IAC 
R **ON A/C 001-012, 014-099,

Subtask 33-51-38-860-054

B. Aircraft Maintenance Configuration

(1) Make sure that the stepladder is in position:


FOR 10WL
at the left FWD passenger/crew door,
FOR 13WL
between the AFT passenger/crew doors.

(2) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

(3) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(4) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT
EMER pushbutton switch and its integral light are off.

(5) If the emergency power-supply unit supplies overwing emergency


lights, make sure that these overwing emergency lights operate:

(a) Pull down and remove the cover flap from one of the related
hatches.

NOTE : The SLIDE ARMED light on the cabin lining at the emergency
____
exits comes on.

(b) Push the latch pin against the spring and turn it a quarter turn
counterclockwise to retract it to the DISARMED position.

NOTE : The SLIDE ARMED light goes off.


____

(c) Make sure that the overwing emergency lights come on.

(d) Push the latch pin against the spring and turn it a quarter turn
clockwise to extend it to the ARMED position.

NOTE : The SLIDE ARMED light comes on.


____

(e) Make sure that the overwing emergency lights go off.


R

EFF :

001-012, 014-099,  33-51-38

Page 430
Aug 01/07
 
IAC 
(f) Install and close the removed cover flap on the related hatch.

NOTE : The SLIDE ARMED light goes off.


____

(6) On the overhead panel 25VU, set the EMER EXIT LT switch 4WL to the ON
position.

(7) Make sure that the other loads connected to the emergency
power-supply unit operate.

(8) On the overhead panel 25VU, set the EMER EXIT LT switch 4WL to the
OFF position.

**ON A/C 101-199,

Subtask 33-51-38-860-054-B

B. Aircraft Maintenance Configuration

(1) Make sure that the stepladder is in position:


FOR 10WL
at the left forward passenger/crew door
FOR 11WL
between the rear emergency exit doors
FOR 12WL
between the rear emergency exit doors
FOR 13WL
between the aft passenger/crew doors
FOR 14WL
between the forward emergency exit doors
FOR 15WL
between the forward emergency exit doors.

(2) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


002).

(3) On the overhead panel 25VU, make sure that the NO SMOKING switch
190RH is in the OFF position.

(4) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
pushbutton and its internal light are off.

(5) On the overhead panel 25VU, set the EMER EXIT LT switch 4WL to the ON
position.


R

EFF :

001-012, 014-099, 101-199,  33-51-38

Page 431
Aug 01/07
 
IAC 
(6) Make sure that the loads connected to the emergency power-supply unit
operate.

(7) On the overhead panel 25VU, set the EMER EXIT LT switch 4WL to the
OFF position.

R **ON A/C 901-999,

R Subtask 33-51-38-860-054-C

R B. Aircraft Maintenance Configuration

R (1) Make sure that the stepladder is in position:


R FOR 10WL
R at the left forward passenger/crew door
R FOR 13WL
R between the AFT passenger/crew doors.

R (2) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-


R 002).

R (3) On the overhead panel 25VU, make sure that the NO SMOKING switch
R 190RH is in the OFF position.

R (4) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER
R pushbutton and its internal light are off.

R (5) If the emergency power-supply unit supplies overwing emergency


R lights, make sure that these overwing emergency lights operate:

R (a) Pull down and remove the cover flap from one of the related
R hatches.

R NOTE : The SLIDE ARMED light on the cabin lining at the emergency
____
R exits comes on.

R (b) Push the latch pin against the spring and turn it a quarter turn
R counterclockwise to retract it to the DISARMED position.

R NOTE : The SLIDE ARMED light goes off.


____

R (c) Make sure that the overwing emergency lights come on.


R

EFF :

101-199, 901-999,  33-51-38

Page 432
Aug 01/07
 
IAC 
R (d) Push the latch pin against the spring and turn it a quarter turn
R clockwise to extend it to the ARMED position.

R NOTE : The SLIDE ARMED light comes on.


____

R (e) Make sure that the overwing emergency lights go off.

R (f) Install and close the removed cover flap on the related hatch.

R NOTE : The SLIDE ARMED light goes off.


____

R (6) On the overhead panel 25VU, set the EMER EXIT LT switch 4WL to the ON
R position.

R (7) Make sure that the other loads connected to the emergency
R power-supply unit operate.

R (8) On the overhead panel 25VU, set the EMER EXIT LT switch 4WL to the
R OFF position.

**ON A/C ALL

4. Procedure
_________

**ON A/C 001-012, 014-099,

(Ref. Fig. 401/TASK 33-51-38-991-001)

**ON A/C 101-199,

(Ref. Fig. 401A/TASK 33-51-38-991-001-B)

**ON A/C 901-999,

(Ref. Fig. 401B/TASK 33-51-38-991-001-A)



EFF :

ALL  33-51-38

Page 433
Aug 01/07
 
IAC 
R **ON A/C 001-012, 014-099,

Subtask 33-51-38-420-052

A. Installation of the Battery of the Emergency Power-Supply Unit

NOTE : Make sure that the contacts between the battery and the emergency
____
power supply unit are clean and in good condition.

(1) Carefully install the battery (6) to the emergency power-supply unit
(1) with the screws (5) and tighten.

NOTE : Make sure that the battery is fully charged before you install
____
it to the emergency power-supply unit (Ref. CMM 335107).

NOTE : To measure and keep the load values, the load programming
____
(TEACH IN) of the EPSU starts automatically when:
- the AC and the DC power are available,
- on the FAP 120RH the LIGHT EMER pushbutton switch and its
integral light are off,
- on the overhead panel 25VU the EMER EXIT LT switch 4WL is in
the OFF position,
- on the overhead panel 25VU the NO SMOKING switch 190RH is in
the OFF position,
- the overwing emergency lights are off,
- the emergency power-supply unit is installed on the A/C for
the first time, or
the battery was removed for more than 5 s and is then
installed again.

R **ON A/C 101-199,

R Subtask 33-51-38-420-052-C

R A. Installation of the Battery of the Emergency Power-Supply Unit (EPSU)

R (1) Make sure that the contacts between the battery and the EPSU are
R clean and in good condition.

R (2) Carefully install the battery (6) to the EPSU (1) with the screws (5)
R and tighten.


R

EFF :

001-012, 014-099, 101-199,  33-51-38

Page 434
Aug 01/07
 
IAC 
R (3) Make sure that the battery is fully charged before you install it to
R the EPSU (Ref. CMM 335107).

R NOTE : To measure and keep the load values, the load programming
____
R (TEACH IN) of the
R EPSU starts automatically when:
R - The AC and the DC power are available.
R - On the Flight Attendant Panel (FAP) 120RH the EMER button
R and its light are off.
R - On the overhead panel 25VU the EMER EXIT LT switch 4WL is in
R the OFF position.
R - On the overhead panel 25VU the NO SMOKING switch 190RH is in
R the OFF position.
R - The EPSU is installed on the A/C for the first time, or
R the battery was removed for more than 5 s and is then
R installed again.

R **ON A/C 901-999,

R Subtask 33-51-38-420-052-B

R A. Installation of the Battery of the Emergency Power-Supply Unit (EPSU)

R (1) Make sure that the contacts between the battery and the EPSU are
R clean and in good condition.

R (2) Carefully install the battery (6) to the EPSU (1) with the screws (5)
R and tighten.

R (3) Make sure that the battery is fully charged before you install it to
R the EPSU (Ref. CMM 335107).

R NOTE : To measure and keep the load values, the load programming
____
R (TEACH IN) of the EPSU starts automatically when:
R - The AC and the DC power are available.
R - On the Flight Attendant Panel (FAP) 120RH the EMER button
R and its light are off.
R - On the overhead panel 25VU the EMER EXIT LT switch 4WL is in
R the OFF position.
R - On the overhead panel 25VU the NO SMOKING switch 190RH is in
R the OFF position.
R - The overwing emergency lights are off.
R - The EPSU is installed on the A/C for the first time, or
R the battery was removed for more than 5 s and is then
R installed again.


R

EFF :

101-199, 901-999,  33-51-38

Page 435
Aug 01/07
 
IAC 
**ON A/C 001-012, 014-099,

Subtask 33-51-38-710-052

B. Do this test.

NOTE : The test is the same for all batteries of the emergency
____
power-supply units.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
**ON EPSU P/N 3214-5X

1. On the emergency power-supply On the emergency power-supply unit:


unit:
- push the TEST pushbutton for - the green LED
approx. 2 s. - BATTERY OK,
- INTERNAL LOADS OK,
- EXTERNAL LOADS OK
come on for approx. 1 min, if all
test loops are completed without
malfunction.
**ON EPSU P/N 3214-54-10

2. On the emergency power-supply On the emergency power-supply unit:


unit:
- push the TEST membrane switch - the green SYSTEM OK LED comes on for
for approximately 2 s. approximately 30 s if all test loops
are completed without malfunction.


R

EFF :

001-012, 014-099,  33-51-38

Page 436
Aug 01/07
 
IAC 
**ON A/C 101-199, 901-999,

Subtask 33-51-38-710-052-A

B. Do this test.

NOTE : The test is the same for all batteries of the emergency
____
power-supply units.

-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------

1. On the emergency power-supply On the emergency power-supply unit:


unit:
- push the TEST membrane switch - the green SYSTEM OK LED comes on for
for approximately 2 s. approximately 30 s if all test loops
are completed without malfunction.

**ON A/C ALL

5. Close-up
________

**ON A/C 001-012, 014-099,

Subtask 33-51-38-410-053

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the ceiling panel:


FOR 10WL
install 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-
42-400-001).

(3) Install the lower sidewall panel:


FOR 11WL
install 241KW at the left emergency exits (Ref. TASK 25-23-44-400-
001),
FOR 12WL
install 242KW at the right emergency exits (Ref. TASK 25-23-44-400-
001).



EFF :

ALL  33-51-38

Page 437
Aug 01/07
R  
IAC 
(4) Install the door frame lining:
FOR 13WL
install 261KW at the left AFT passenger/crew door (Ref. TASK 25-23-
45-400-008).

(5) Remove the stepladder(s).

**ON A/C 101-199,

Subtask 33-51-38-410-053-B

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the ceiling panel:


FOR 10WL
install 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-
42-400-001),
FOR 11WL
install 251KC between the rear emergency exit doors (Ref. TASK 25-23-
41-400-001),
FOR 12WL
install 251KC between the rear emergency exit doors (Ref. TASK 25-23-
41-400-001),
FOR 14WL
install 231JC between the forward emergency exit doors (Ref. TASK 25-
23-41-400-001),
FOR 15WL
install 231JC between the forward emergency exit doors (Ref. TASK 25-
23-41-400-001),

(3) Engage the emergency oxygen container:


FOR 13WL
lift and engage the emergency oxygen container 33WR between the AFT
passenger/crew doors (Ref. TASK 35-21-41-400-001).

(4) Remove the stepladder(s).



EFF :

001-012, 014-099, 101-199,  33-51-38

Page 438
Aug 01/07
 
IAC 
**ON A/C 901-999,

Subtask 33-51-38-410-053-A

A. Close Access

(1) Make sure that the work area is clean and clear of tool(s) and other
items.

(2) Install the ceiling panel:


FOR 10WL
install 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-
42-400-001).

(3) Install the lower sidewall panel:


FOR 11WL
install 241KW at the left emergency exit(s) (Ref. TASK 25-23-44-400-
001),
FOR 12WL
install 242KW at the right emergency exit(s) (Ref. TASK 25-23-44-400-
001).

(4) Engage the emergency oxygen container:


FOR 13WL
lift and engage the emergency oxygen container 33WR between the AFT
passenger/crew doors (Ref. TASK 35-21-41-400-001).

(5) Remove the stepladder(s).

**ON A/C ALL

Subtask 33-51-38-862-052

B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-


002).



EFF :

ALL  33-51-38

Page 439