Parameters in transmission lines

Transmission Line:
Coaxial Cable

a= 3.500E-04 m [meters] Electric conductor radio


Geometric
b= 3.000E-02 m insulation coverage radius
parameters
t= 40+10 m outer conductor thickness
Conductor
σc= 5.800E+07 Sm/m Wire conductivity
properties
σd= 1.000E-16 Sm/m Dielectric Conductivity
εr= 2.250E+00 Relative electrical permittivity
Properties of the
εo= 0.000E+00 C^2/Nm^2 Electric vacuum permittivity
insulator
μr= 1.000E+00 Relative magnetic permeability
μo= 1.257E-06 Tm/A Magnetic vacuum permeability
frequency f= 103000 Hz Frecuency

Penetration depth δp= 2.002E-04 m Penetration depth


Range= Medium frecuency Frequency range
RAC/RDC= 1.657E+00 AC/DC resistance ratio
Parameters in R= 7.750E-02 Ohm/m Resistance
transmission line G= 0.000E+00 Sm/m Conductance
L= 9.902E-07 H/m Inductance
C= 0.0000E+00 F/m Capacitance

r= 0.00021+0.00362i Propagation constant


Distributed a= 0.00020618 Np/m Attenuation constant
parameters b= 0.00361993 Rad/m Phase constant
Zo= 187.94989-10.70487i Ohm Characteristic impedance

propagation Vp= 1.892E+08 m/s Propagation speed


characteristics of λ= 1735.720565 m Wavelength
the wave a[dB/m]= -0.0017896 dB/m Attenuation

Just fill in the spaces in yellow

Vp = w / b = 2 pi f / b
Lambda = 2 pi / b
a[db/m] = -8.68 * a
Zo= 50 Ohm
Transmission Line
ZL= 45-75i Ohm
Features
l= 0.26 Lambda
Input impedance Zin= 11.7914+4.5363i Ohm
T= 0.35154-0.51195i Ohm
Reflection coefficient
T= 0.62103<-55.52384º Ohm
Stationary Wave Ratio VSWR= 4.27741

Example:

Just fill in the spaces in yellow

17.56756757
Characteristic impedance of the line
Load impedance
Electrical length
Input impedance
Input impedance
Stationary Wave Ratio
First plotted point
Put the mouse over the point