DESIGN OF BASE PLATE

Vertical Load over the column(P) 15 kN


Moment in x-direction Mx 0.15 kN-m Y
Moment in y-direction My 0.15 kN-m
Grade of concrete M:25
Allowable bearing pressure of concrete(sc) 8.5 N/mm2
Permissible bending stress in base (s) 250 N/mm2 b

Length of Base plate (l) 200 mm X


Width of Base plate (b) 300 mm
l
Eccentricity(ex & ey)
Area of Plate(A) = 60000 mm2
ex= 10 mm Zxx= 3000000 mm3
ey= 10 mm Zyy= 2000000 mm3

ex/lx 0.05 CASE 1 P/A = 0.25


ey/ly 0.033333333 CASE 1 Mx/Zxx= 0.05
My/Zyy= 0.075
CASE 1 e/l <1/6 There is no Tension OR Only comp. stress throughout
CASE 2 e/l >1/6 Tension developed at some portion pmax.= 0.375 Hence Safe

CASE 1
Width of base plate 8.82354265 mm ~ 300 mm x
Max. comp. stress at the edge of plate 0.4

Min. comp. stress at far end 0.25 125

Srress at critical section x-x 0.3375

Moment at crirical section x-x= 3450.52083 N-mm 0.25 0.25

M.R. at section x-x = Moment at section x-x


0.15
M.R. at section x-x = 1/6*t^2*s= 3450.52083

t= 9.10013736 mm
x x
CASE 2
Anchor bolts are not resisting the over-turning moment
125
Taking moment at the centre of Base
(Mx/P)+(My/P) = (L/2)-y

y= 80
3y
3*y = 240
c.g.+ px
Width of Base plate = 14.70588 mm = 300 mm y p

Actual Maximum intensity of pressure (p')= 0.416667 N/mm2


x
The intensity of pressure at section x-x at a distance 125 mm

px = 0.1996528

B.M. at section x-x in cantilevered portion of 1 mm strip

= 1559.787 + 1130.846

= 2690.633 N-mm

M.R. at section x-x = 1/6*t^2*s= 2690.633


(for 1mm strip)
t^2= 64.5752

t= 8.035869 mm
Gusset Plate
Providing gusset plate 16 mm
Gusset angle 2ISA150x150x10