CALCULATION SHEET

DESIGNED FOR STILT+5 FLOORS


Office : Calculated : naga Date :
Ref No./Dwg No. Checked : Date :
Project: AT Rayadurgam Remarks :
DESIGN OF SLOPED FOOTING
FOOTING NO. F1 196.5
Unit
PU (p*1.5) T 500.00
MU T-M 300.00
SBC T/SQM 20.00
B
FOS 1.50
b
AREA req SQM 18.33
LENGTH (L) M 4.70 l
BREADTH (B) M 4.00
muy
D depth MM 1500
d effective depth MM 1432 (L)
edge thk (T) MM 381 0 mux
Chk for sbc T/SQM 31.31
Shorter side column (b)(pedestal) M 0.400 D 59.0551181 INCHES
Longer sidecolumn (l)(pedestal) M 0.600 d $ 15.00 INCHES
PROJECTION ALROUND 0.100 Footing 15.42 6'3"
PRO-SS (b') 0.600 1.2875 13.12 6'3"
PRO-LS (l') 0.800 1.025 column 9"x21"
Width of footing Shorter side M 4.000 pedestal 0
Width of footing longer side M 4.700
OH-Lx M 1.800
Mux T-M 228.420
Kx N/SQMM 0.865
Pt-x % 0.25
Ast-x SQMM 4663.0 31915
Dia of bar 10mm 12mm 16mm 20mm 25mm
No of bar req 59 41 23 15 10
OH-Ly M 2.050
Muy TM 194.0
Ky N/SQMM 0.923
Pt-y % 0.27
Ast-y SQMM 3975.97
Dia of bar 10mm 12mm 16mm 20mm 25mm
No of bar req 51 35 20 13 9

CHECK FOR ONE WAY SHEAR - LONGER DIRECTION


projection MM 368.000
b' MM 3264.00
d' MM 568.231
SF T 44.160
AREA FOR SHEAR 2163781
Tow-v N/SQMM 0.20 provide pt
Pt % 0.216 0.167
Tow-c N/SQMM 0.354 safe

TWO WAY SHEAR


Perimeter MM 7728.00
P-area SQM 3.72
Punch-load T 452.32
upword force T 106.09
Net downword force 457.91
d/2 716.00
eff edge thick 326.00
m 1143604.0
n 1750.00
D'' 979.49
PSS N/SQMM 0.598
Beta-c 0.67
ks 1.17
fck N/SQMM 20.00
tow-c 1.12
Per.punching shear stress (T v) 1.12 > 0.598 safe
spacing in longer dic c/c T 12 114 mm
spacing in shorter dic c/c T 12 114 mm
footing volume = 15.48 m3 wt / m3 22 kg/m3
weight of steel = 331 kg