STRUCTURAL ANALYSIS AND DESIGN

DATA AND SPECIFICATIONS :


Owner : MR. PAULINO ULBA
Name of Project : Proposed ONE STOREY POULTRY HOUSE
Location of Building : BRGY. MUTA KASIBU, NUEVA VIZCAYA
Unit Wt. Of concrete : 24.00 KN / m3.
Exterior Walls : 2.11 KN / m2.
Slab Thickness ( t ) : 0.125 m.
Live Loads ( LL ) : 4.80 KN / m2.
Live Loads on stairs : 2.40 KN / m2.
Super imposed DL : 1.45 KN / m2.
height of CHB : 2.80 m.
Stair : 4.80 KN / m2.

Design Specifications / Criteria :

fc' = 20.70 Mpa n= 10.00


fs = 124.00 Mpa E= 17,300.00 Mpa
fy = 280.00 Mpa Sp= 170.00 Mpa
Fy= 0.70 Mpa

۷allow. = 0.17(fc') - for beam stress


= 0.33(fc') - for punching shear

μallow. = 10.12(fc')/D for Bond Shear

Seismic load provisions - Allowable 10 - 20 % of DL and LL

Prepared by :

JANSEN B. TABDI
Civil Engineer
PRC No. : 158015
PRTR No. : 6087158
D-Issued: : April 3, 2019
P-Issued: : La Trinidad, Benguet
DESIGN OF COLUMNS :

C 1: Design Load P = 110.00 KN

Add 15 % for Seismic load provision :

Pu= 126.50 KN

Using = 0.013

Ag = Pu / [ø (0.80) { 0.85 x fc' ( 1 - ρg ) + (fy x ρg) }]

= 10753.5945654 mm^2
? ?
CHECK ACTUAL COLUMN SIZE : USE 250 X 250

Ag = 62500 mm^2 10753.59457 mm^2 Required

Therefore Very S A F E ! ! !

CHECK FOR STEEL REQUIREMENT :

As = ρg x Ag = 812.5 mm2

Using 16 mm ø RSB : n = 4.04103403 4 pcs.

Check Area of Steel :

Ast = 812.5 mm^2 812.5 mm^2 = As req'd

Therefore Very S A F E ! ! !

therefore adopt : 250 x 250 column with 4 16 mm^2 ø


RSB with 10 mm ø RSB as stirrups spaced at 7 @ 0.05 m.; 3 @ 0.10 m.; 3 @ 0.15 m. and
rest at 0.20 m. on center.

check Spacing of stirrups :


1 16 ø = 256 mm.
2. 48 x tie ø = 480 mm.
3. Least dimension = 250 mm.

CHECK FOR Pu allow. :


Pu = Φ (0.80) { 0.85 x Fc' x ( Ag - Ast ) + fy x Ast }

= 607.82519 KN 110.00 KN
therefore S A F E !!!

DESIGN OF FOOTING:

Use Pu = 110.00 KN

Using Sp = 170.00 Mpa

A req'd = Pu / Sp = 0.6470588235 m2

Using 0.8043996665 0.8

APPROX. USE 0.5 X 0.5

Sp net = Pu / A = 440 KN/ m2

CHECK FOR BENDING SHEAR :

use = ρmin = 1.4 / fy = 0.005

w = fy / fc' = 0.0676328502 X = 0.125

0
0.5 0.25
Mu = Sp x Ab x X/2

= 1.71875 KN.m.
0.5 m.

DESIGN DEPTH d OF FOOTING :

Mu = Φ fc' . Bd^2 x (ω) ( 1 - 0.59ω)

Mu = 604.860869565 d^2

d = 53.3063088049 mm. + 100 mm steel cover = 153.3063

therefore d 300 mm.


STEEL REQUIREMENT :

As = min. L . d min = 0.0035

= 268.286040409 mm^2

TRY = 16 mm ø RSB

Ao = 201.0624 mm^2

N = As / Ao = 1.5343421764

SAY 2 PCS. - 16 mm ø RSB

MINIMUM : 2 PCS. - 16 mm ø RSB MATTING


BOTHWAYS FOR 0.5 X 0.5 X 300
FOOTING .

P= 110.00 Kn.

300 mm.

L= 0.50 m.
w= 0.50 m.
0.50
0.50 0.25

0.25

USE : 6 PCS. - 16 mm ø RSB MATTING

You might also like