N series / Y series / A series ◎CAD Data (DXF) is available in compact disc.

An Example of Standard Item Number

H N−N 21MP−L60−A A C ***


A B C D E F G H I
1 APPLICABLE INSPECTION/STANDARD
ITEM # Inspection/Standard - Please select the ITEM # which suits the regulations at the place for the accumulator
installation.
H High Pressure Gas Safety Law (Japan Authorization) Inspection Product
- Please refer to "The List of Applicable Inspection Code Stamps Per Pressure and Gas
F Labor Industrial Safety and Health Law (Japan) Volume" and confirm the applicable combination of pressure and gas volume for each
M ASME (U.S.A. etc) Inspection/Standard.
S ASME (Canada)
R PED (CE Marking)
D SARMBPV (China) Inspection Product (NOTE1)
N NACOL (NACOL Company Inspection)
NOTE1 - Mark D applies to the accumulator certified SARMBPV (Supervision Administration Regulation for Manufacture of Boiler and Pressure Vessel: China).
- When installing the accumulator at user, Chinese government requires an inspection to satisfy "the Supervisory Inspection for Safety Performance of the products", sometimes.
Then, the user shall perform that inspection on such occasion.
- Unless otherwise specified, the design and/or quality control standard inspection should be made in accordance with the "High Pressure Gas Safety Law, Japan".
- When other standard or code accumulator were in need, please tell that to our sales department beforehand.
2 BLADDER COMPOUND
ITEM # Bladder Compound Suitable Service Fluid Allowable Service Temp - Please select the ITEM # of Bladder
Compound which suits "Service Fluid" and
N Standard Nitrile Rubber (NBR) Turbine Oil (JIS K2213), Fatty Ester Fluid, Water -10 ~ +70 °C
"Service Temperature".
H Nitrile Rubber for High Temp. Use (H.NBR) Glycol Fluid, W/O Emulsion Fluid, O/W Emulsion -10 ~ +110 °C - The bladder compound of standard
L Nitrile Rubber for Low Temp. Use (L.NBR) Fluid, Biodegradable Fluid, Tap Water, Sea Water -35 ~ +70 °C accumulator is Standard Nitrile Rubber (NBR)
F Butyl Rubber (IIR) Phosphate Ester Fluid and the ITEM # is "N".
-10 ~ +70 °C - If you have any questions, please do not
E Ethylene Propylene Rubber (EPDM) Phosphate Ester Based Fluid hesitate to ask our sales department.
C Chloroprene Rubber (CR) Basic, Water -20 ~ +80 °C
G Epichlorohydrin Rubber (CHC) (NOTE2)
V Fluorine Rubber (FKM)
NOTE2 - When CHC bladders were chosen, "B" should be filled in 8, and the internal coating specification would be recommended.
However, when the fluid harmful for the paint were used, please consult with our sales department about the suitable specification before you issue an order.
3 SERIES 4 MAXIMUM ALLOWABLE WORKING PRESSURE (MAWP) 5 GAS VOLUME
ITEM # Series Name ITEM # MAWP ITEM # MAWP ITEM # MAWP In case 1 is R ITEM # Gas Volume ITEM # Gas Volume
N N series (20 ~ 160L) 15 15MPa 25MP 25MPa 33MP 33MPa ITEM # MAWP L20 20L L60 60L
Y Y series (60L) 17.5 17.5MPa 26MP 26MPa 35MP 35MPa 210B 210Bar L30 30L L80 80L
A A series (160L) 21MP 21MPa 28MP 28MPa 50MP 50MPa L40 40L 120 120L
- Please select the Item # which 23MP 23MPa 31.5 31.5MPa L50 50L 160 160L
shows the series name. - Please select the ITEM # which value exceeds the maximum operation pressure. - Please select the ITEM # which value exceeds the
- The maximum allowable working pressure (MAWP) is the maximum pressure, required gas volume(L) calculated by accumulator sizing
which is permitted to load the accumulator. calculation.
THE LIST OF APPLICABLE INSPECTION CODE STAMPS PER PRESSURE AND GAS VOLUME
MAWP Gas Volume (L) In case MAWP Gas Volume (L)
(MPa) 20 & 30 40 ~ 60 Y60, 80 • 120 160 A160 1 is R (MPa) 20 & 30 40 ~ 60 Y60, 80 • 120 160 A160
15 H, F, M, D, N 28 H, F, D, N
17.5 H, M, D, N H, F, M, D, N 31.5 H, F, D, N
21 H, M, S, R, D, N H, F, M, S, R, D, N 210 33 H, F, D, N
23 H, M, D, N H, F, M, D, N H, F, M, D, N 35 H, M, D, N H, F, M, D, N
25 H, F, M, D, N 50 H*, D, N H*, F, D, N
35 H, F, D, N *: NOTE3 When the High Pressure Gas Safety Law, Japan is applied, available max. allowable working press. is 49.1MPa.
6 SPECIFICATION FOR ACCUMULATOR CAP & GAS CHARGING SIDE (NOTE4)
- Please select the ITEM # which suits the gas charging side specification, accumulator cap specification and material. The ITEM # of standard accumulator is "A".
- When you need to monitor the pressure constantly, we recommend to select ITEM # "Q" (Fig.2) or "R" (Fig.3).
They have the "SG valve" which can be installed into the accumulator gas charging side permanently.
ITEM # Gas Charging Side Specification Acc. Cap Specification Shape
A Standard Type (Fig. 1) Spring Loaded Type Safety Valve SG Valve
H Plating SG Valve Pressure
Dynac Gas Valve (G thread) Dynac Gas Valve Gauge

Pressure
P Stainless Steel Gauge Fuse Plug
D Two pieces type of Acc. Cap
U Standard Type (Fig. 1)
L Plating
Dynac Gas Valve (UNF thread)
N Stainless Steel
K Two pieces type of Acc. Cap
Q SG Valve + Spring Loaded Type Safety Valve + Pressure Gauge SG Type (Fig. 2)
R SG Valve + Fuse Plug + Pressure Gauge SG Type (Fig. 3)
7 SPECIFICATION FOR OIL PORT SIDE (NOTE5) NOTE4
- Please select the ITEM # which valve material suits the service fluid. Allowable oil flow in/out speed when Fuse Plug
- The ITEM # "A" is for the standard model. vertically installed (16 ~ 320 cSt)
ITEM # Oil Port Side Specification Valve Material Specification N series 20 ~ 60L 600L/min
Pressure Gauge
A Standard Material (Carbon Steel) Y, N series 20, 80 & 120L Containing Glycerol
900L/min SG Valve
D Standard Type Stainless Steel Material A series 160L
- For installing the SG Valve to the
C Poppet Valve: Stainless + Oil Port Valve: Plating N series 160L 1,200L/min accumulator cap, turnbuckle (See
NOTE5 - When the required oil flow volume exceeds the above allowance, please select the high flow type accumulator (page 52 ~ 59). Page 38) is necessary.
8 SPECIFICATION FOR ACCUMULATOR SHELL (NOTE6) - The pressure scale of pressure gauge
- Please select the ITEM # which material of shell and surface treatment suits the operating circumstance and service fluid. is in MPa.
- The ITEM # "C" is for standard accumulator. Suitable rust-prevention treatment corresponding to the installation place is required. - The standard pressure gauge for SG
Valve is containing glycerol.
ITEM # Material of Shell Treatment Specification Service Fluid - Please refer to the table on page 40,
C Zinc Phosphate Treatment on Inside & Outside Petroleum based Hydraulic Oil & Other Fluid and select the suitable pressure gauge.
D Surface (Standard Spec.) Fire Resistant Fluid (WG) - Turnbuckle, pressure gauge containing
glycerol, fuse plug and spring loaded
A Standard Standard Paint Coating on Inside & Outside Surface type safety valve are option articles.
B Material Standard Paint Coating on Inside only Petroleum based Hydraulic Oil & Other Fluid
N Carbon Standard Paint Coating on Outside Surface NOTE6
- The "Standard Paint Coating" on the table means as
W Steel Zinc Phosphate Treatment on Inside Surface Fire Resistant Fluid (WG)
follows:
H Petroleum based Hydraulic Oil & Other Fluid Heat Hardening Type Painting: Heat Hardening Type
Standard Plating on Inside & Outside Surface
F Fire Resistant Fluid Acrylic Resin/Painting Color: Munsell Hue No.5GY9/1
- When the Fire resistant fluid or the fluid harmful for the paint were used, there would be a possibility of pealing off of the painting from the inside surface.
So, on such case consult with our sales department about the suitable specification before you issue an order.
9 SPECIAL SPECIFICATION
ITEM # Special Specification - Please select the ITEM # which suits
Blank When there is no special specification: Blank / When there is special specification: 3 digits number filled in.

36
N (Y · A) series : 20 ~ 160L



75
A B 20 85 852 859 326
90
97
250
A B 30 112 1,097 1,104 571 N175:160
118
123 267.4
A B 40 140 1,312 1,319 85 157 786 400 77 M60×2
148 [C267]
156 210
A B 50 180 1,634 1,641 1,108 N230:165
190
168
700
A B 60 190 1,772 1,779 1,246 100
200
170 1,286 Y
A B 60 220 1,326 638 N 150:210
250 (1,295)
400
210 1,541 355.6 Y
A B 80 270 1,581 99 210 893 92.5 N 210:230 M75×2
310 (1,550) [C350]
270 1,993 Y
A B 120 360 2,033 1,345 N 250:230
410 (2,002)
1,000
370 406.4
A B 160 490 2,088 2,128 119 246 1,340 110 260 M90×2
500 [C406]
150 865 872
A B 20 320
150 <865> <->
250
205 1,110 1,117
A B 30 565
205 <1,110> <->
255 1,325 1,332 298.5
A B 40 95 164 780 400 77 200 M60×2
255 <1,325> <-> [C298]
330 1,647 1,654
A B 50 1,102
330 <1,647> <->
700
355 1,785 1,792
A B 60 1,240 100
355 <1,785> <->
220
A B 60 1,286 1,326 638
250
400
270 355.6
A B 80 1,541 1,581 99 210 893 92.5 230
310 [C350]
M75×2
360
A B 120 1,993 2,033 1,345
410
1,000
460 406.4 A260:280
A B 150 2,101 2,107 97 256 1,342 111
540 [C406] A315:300
q A B

w
e
r
t
37