Operating Equip Area

Equipment Details Flash Point Auto Ign. Source of Release Equip Hazard Radius
Material Type Conditions Fluid Temp Class Hole Size Classification of the
Ventilation Temp 0C Temp 0C Gas IP Code Reference Notes & Remarks Holds Rev
Handled Press Category (mm) Vertical Horizantal Equipment
Tag No. Description Temp C 0 (Note 1) (Note 2) Description Grade Class Group Zone
bara (R1) (R2)
HC Gas Open Area / Flammable Flanges, Valves &
65 98 >450 Secondary G(i) T1 IIA Zone 2 2 1.5 2 IP15 Table C9(a), (b)
(Methane Rich) Natural Gas Instrument Connections.
Zone 2, IIA, T3
Open Area / Flanges, Valves &
HC Liquid 65 98 Note - 1 >200 Secondary C T3 IIA Zone 2 2 5 6 IP15 Table C9(a), (b)
Natural Instrument Connections.

Since the pressure is above 100barg, Haz


HC Gas Open Area / Flammable Flanges, Valves &
68 107 >450 Secondary G(i) T1 IIA Zone 2 2 1.7 2 IP15 Table C9 (b) Radius determined using Shell Fred
(Methane Rich) Natural Gas Instrument Connections.
software.
Since the pressure is above 100barg, Haz
Open Area / Flanges, Valves &
HC Liquid 68 107 Note - 1 >200 Secondary C T3 IIA Zone 2 2 5.5 6 Zone 2, IIA, T3 IP15 Table C9 (b) Radius determined using Shell Fred
Natural Instrument Connections.
software.

Open Area / Flanges, Valves &


Aqueous Fluid 68 107 -- -- Unclassified
Natural Instrument Connections.

Since the pressure is above 100barg, Haz


HC Gas Open Area / Flammable Flanges, Valves &
68 107 >450 Secondary G(i) T1 IIA Zone 2 2 1.7 2 IP15 Table C9 (b) Radius determined using Shell Fred
(Methane Rich) Natural Gas Instrument Connections.
software.
Since the pressure is above 100barg, Haz
Open Area / Flanges, Valves &
HC Liquid 68 107 Note - 1 >200 Secondary C T3 IIA Zone 2 2 5.5 6 Zone 2, IIA, T3 IP15 Table C9 (b) Radius determined using Shell Fred
Natural Instrument Connections.
software.

Open Area / Flanges, Valves &


Aqueous Fluid 68 107 -- -- Unclassified
Natural Instrument Connections.

Since the pressure is above 100barg, Haz


HC Gas Open Area / Flammable Flanges, Valves &
60 105 >450 Secondary G(i) T1 IIA Zone 2 2 1.7 2 IP15 Table C9 (b) Radius determined using Shell Fred
(Methane Rich) Natural Gas Instrument Connections.
software.
Since the pressure is above 100barg, Haz
Open Area / Flanges, Valves &
HC Liquid 60 105 Note - 1 >200 Secondary C T3 IIA Zone 2 2 5.5 6 Zone 2, IIA, T3 IP15 Table C9 (b) Radius determined using Shell Fred
Natural Instrument Connections.
software.

Open Area / Flanges, Valves &


Aqueous Fluid 60 105 -- -- Unclassified
Natural Instrument Connections.

Since the pressure is above 100barg, Haz


HC Gas Open Area / Flammable Flanges, Valves &
63 106 >450 Secondary G(i) T1 IIA Zone 2 2 1.7 2 Zone 2, IIA, T3 IP15 Table C9 (b) Radius determined using Shell Fred
(Methane Rich) Natural Gas Instrument Connections.
software.
Since the pressure is above 100barg, Haz
HC Gas Open Area / Flammable Flanges, Valves &
60 105 >450 Secondary G(i) T1 IIA Zone 2 2 1.7 2 Zone 2, IIA, T3 IP15 Table C9 (b) Radius determined using Shell Fred
(Methane Rich) Natural Gas Instrument Connections.
software.
Since the pressure is above 100barg, Haz
HC Gas Open Area / Flammable Flanges, Valves &
60 106 >450 Secondary G(i) T1 IIA Zone 2 2 1.8 2 Zone 2, IIA, T3 IP15 Table C9 (b) Radius determined using Shell Fred
(Methane Rich) Natural Gas Instrument Connections.
software.
Since the pressure is above 100barg, Haz
Open Area / Flanges, Valves &
HC Liquid 60 105 Note - 1 >200 Secondary C T3 IIA Zone 2 2 3.3 6 Zone 2, IIA, T3 IP15 Table C9 (b) Radius determined using Shell Fred
Natural Instrument Connections.
software.
Since the pressure is above 100barg, Haz
HC Gas Open Area / Flammable Flanges, Valves &
65 104 >450 Secondary G(i) T1 IIA Zone 2 2 1.7 2 Zone 2, IIA, T3 IP15 Table C9 (b) Radius determined using Shell Fred
(Methane Rich) Natural Gas Instrument Connections.
software.

Open Area / Flammable >450 (Gas) Flanges, valves &


HC Gas & HC Liquid 72 112 Secondary G(i) T1 IIA Zone 2 2 1.9 2 Zone 2, IIA, T3 IP15 Table C9(a), (b) Off Plot Facility
Natural Gas >200 (Liq) Instrument Connections

HC Gas Flammable Inside buried pit is Zone 1.


Closed Amb Atm >450 Pit Vent Secondary G(i) T1 IIA Zone 2 101.6 2 -- Zone 2, IIA, T3 Table 5.4 and Section 5.4.9
(Methane Rich) Gas Drains from Wellhead.

Since the hole size =pipesize (> 10 mm),


HC Gas Open area / Flammable 100
Amb Atm >450 Vent Secondary G(i) T1 IIA Zone 2 2 -- Zone 2, IIA, T3 Haz Radius determined using Shell Fred
(Methane Rich) Natural Gas (Vent Dia)
software
The instrument air package is located in
unclassified non-hazardous area and all the
Air Partially Enclosed Amb 10 Instrument Air Unclassified Unclassified electrical equipment including motor on
compressor skid is suitable for unclassified
non-hazardous area only

Open Area / Flammable >450 (Gas) Flanges, valves &


HC Gas & HC Liquid 72 112 Secondary G(i) T1 IIA Zone 2 2 1.9 2 Zone 2, IIA, T3 IP15 Table C9(a), (b) Off Plot Facility
Natural Gas >200 (Liq) Instrument Connections

HC Gas Flammable Inside buried pit is Zone 1.


Closed Amb Atm >450 Pit Vent Secondary G(i) T1 IIA Zone 2 101.6 2 -- Zone 2, IIA, T3 Table 5.4 and Section 5.4.9
(Methane Rich) Gas Drains from Wellhead.

Since the hole size =pipesize (> 10 mm),


HC Gas Open area / Flammable 100
Amb Atm >450 Vent Secondary G(i) T1 IIA Zone 2 2 -- Zone 2, IIA, T3 Haz Radius determined using Shell Fred
(Methane Rich) Natural Gas (Vent Dia)
software.
The instrument air package is located in
unclassified non-hazardous area and all the
Air Partially Enclosed Amb 10 Instrument Air Unclassified Unclassified electrical equipment including motor on
compressor skid is suitable for unclassified
non-hazardous area only

HC Gas Open Area / Flammable Flanges, Valves &


75 7 >450 Secondary G(i) T1 IIA Zone 2 2 1 1 Zone 2, IIA, T3 IP15 Table C9(a), (b)
(Methane Rich) Natural Gas Instrument Connections