3. HAZARDS IDENTIFICATION
HMIS RATING
HEALTH – 2 FLAMMABILITY – 3 REACTIVITY – 0
minimal…0 slight…1 moderate…2 serious…3 severe…4
Emergency Overview
Physical Appearance: Coloured liquid with a characteristic odor.
Potential Health Effects
INGESTION : Solvents present in this mixture may be fatal if swallowed. Also small
quantity may effect nervous system and cause abdominal discomfort.
INHALATION : Can cause moderate respiratory irritation, dizziness, fatigue, nausea &
headache.
Micro Inks Limited, Regd Off: Bilakhia House, Muktanand Marg, Chala, Vapi 396 191, Gujarat, India
T +91 260 2462811 / 0284, F +91 260 2463733 www.microinks.com
Page 1 of 5
4. FIRST AID MEASURES
EYES : Immediately flush eyes with plenty of water for two to three minutes. Remove
any contact lenses and continue flushing for 15 minutes. Get medical attention
SKIN : Remove contaminated clothing & immediately wash affected area with plenty
of soap and water. Seek medical attention if necessary. Wash contaminated
clothing before reuse.
INGESTION : Contact local poison control center or physician immediately. Do not induce
vomiting unless instructed so by a physician. If vomiting occurs, keep head
lower than hips to help prevent aspiration. Get medical attention immediately.
INHALATION : Remove to fresh air and supply oxygen if breathing is difficult. Seek medical
attention immediately.
GENERAL HAZARD : Dangerous fire hazard when exposed to heat or flame. Vapor can
flow along surfaces to distant ignition sources and flash back.
‘
EXTINGUISHING : Carbon Dioxide, Dry Chemical, Foam and Water Spray.
MEDIA
EXPLOSION HAZARDS : Above flash point, vapor-to-air mixtures are explosives if within
the flammable limits noted above. Contact with strong oxidizers
may cause fire or explosion.
FIRE FIGHTING : Wear full protective equipment and a self-contained breathing
EQUIPMENTS apparatus with the full face piece operated in the pressure demand
mode. Water spray may be used to keep fire-exposed containers
cool until they can be evacuated.
Micro Inks Limited, Regd Off: Bilakhia House, Muktanand Marg, Chala, Vapi 396 191, Gujarat, India
T +91 260 2462811 / 0284, F +91 260 2463733 www.microinks.com
Page 2 of 5
6. ACCIDENTAL RELEASE MEASURES
COMMENTS:
Ventilate area of leak or spill. Remove all ignition sources. Wear appropriate
personal protective equipment. Contain and recover liquid when possible. Use non-
sparking tools and equipment. Collect liquid in an appropriate container or absorb with an
inert material i.e. sawdust, dry sand, universal binder, acid binder or cloth etc., and place in
a chemical waste container. DO NOT FLUSH TO SEWER. If leak or spill has ignited, use
water spray to disperse any vapor and flush spill away from personnel or other ignitable
materials. When picked up, treat material as prescribed under heading “DISPOSAL”.
GENERAL PROCEDURES:
Protect containers against physical damage. Store in a cool, dry, well-ventilated location,
away from any area where a fire hazard may be acute. Containers should be bonded and grounded for
transfer to avoid static sparks. Do not permit smoking in storage areas. Use only non-sparking tools
and equipment around the liquid. Empty containers may be hazardous from residual liquid and vapor.
Observe all warnings and precautions listed.
EYES & FACE : Wear safety glasses with side shields or goggles when handling this
material.
Micro Inks Limited, Regd Off: Bilakhia House, Muktanand Marg, Chala, Vapi 396 191, Gujarat, India
T +91 260 2462811 / 0284, F +91 260 2463733 www.microinks.com
Page 3 of 5
9. PHYSICAL AND CHEMICAL PROPERTIES
STABILITY : Stable but may react with strong oxidizing agents, concentrated
nitric or sulfuric acid and halogens.
ACUTE TOXICITY : Over exposure to above solvents may cause fatigue, burning of eyes,
confusion, dissiness and drowsiness. Prolonged exposure may cause
unconsciousness.
ENVIRONMENTAL : The product should not be allowed to enter drains of water cources or
DATA soil.
PRODUCT : Material that cannot be saved for recovery or recycle should be handled as a
hazardous waste and disposed of at a govt. approved waste facility to
incinerator. Always dispose in accordance with current regulations of Govt. act
for disposal.
Micro Inks Limited, Regd Off: Bilakhia House, Muktanand Marg, Chala, Vapi 396 191, Gujarat, India
T +91 260 2462811 / 0284, F +91 260 2463733 www.microinks.com
Page 4 of 5
14. TRANSPORT INFORMATION
Road Rail
Proper shipping name: Printing Ink Flammable
Truck – ADR : Loaded: 3-5b Empty: II
Rail – RID/RMP : Loaded: 3-5b Empty: II
UN Number : 1210
Sea
Proper shipping name: Printing Ink Flammable
Sea – IMO/IMDG : Class 3 UN Number:1210 Label: 3
Packing Group : II
Air
Proper shipping name: Printing Ink Flammable
Air – ICAO/IATA : Class: 3 UN Number: 1210 Label: 3
Packing Group : II
Packing Instructions for Passenger: 353 Packing Instructions for cargo: 364
NFPA CODES
: Health :2
Fire :3
Reactivity :0
ADDITIONAL MSDS INFORMATION
The OSHA Hazard Communication Standard,29 CFR 1910.1200,paragraph (g)(4),specifically
permits chemical manufactures to produce single MSDS for a category of complex mixtures where
those mixtures "have similar hazards and contents. "Therefore, this MSDS applies to the range of
products described in Section 1,or all products with the same Product Name listed in section
1.Where specific data is required for the purposes of regulatory reporting, a Technical data sheet will
be provided for the specific product upon request to the Micro Inks Technical Department .
MANUFACTURER DISCLAIMER
Information given herein is offered in good faith as accurate, but with-out guarantee. Conditions of
use and suitability of the product for particular uses are beyond our control; the user therefore
assumes all risks of use of this product. Nothing is intended as a re-commendation for uses, which
infringe valid patents, or as extending license under valid patents. Appropriate warnings and safe