Technical data Pump name 100x80 FS HCA

Customer Date 20-February -2019 Company


Contact Item no. Issued by
Phone Project Phone
E-mail Project ID E-mail

Requested data
1 Pump ty pe End Suction Volute Pump Fluid Water, clean
2 Number of pumps / Reserv e 1 / 0 Liquid temperature °C 20
3 Flow m³/h 200 Kin. v iscosity mm²/s 1
4 Head m 45 Vapour pressure bar 0.022
5 Static head m 0 PH v alue 7
6 Inlet pressure bar 0 Density kg/dm³ 1
7 Av ailable sy stem NPSH 0 Solids Weight % 0
8 Env ironmental temperature °C 20

Pump
9 Pump name 100x80 FS HCA Frequency Hz 50
10 Design End Suction Volute Pump Installation ty pe with base, motor
11 Manuf acturer PTEI Impeller Max. mm 223
12 Speed 1/min 2900 Diameter Designed mm 203
13 No. of Stage 1 Min. mm 187
14 Connection Suction side JIS 10K Flow Operating m³/h 200
15 Connection Discharge side JIS 10K Max- m³/h 287
16 Max Working Pressure bar 10 Min- m³/h 48
17 Shut-of f head bar 5.58 Head Operating m 45.0
18 Total weight kg See the table of "Dimensions". - (Qmax.) m 29.3
19 Shaf t power kW 30.58 - (Qmin.) m 57.1
20 Max. Shaf t Power at max. impeller kW 48.05
21 Required NPSH m 3.3 Ef f iciency % 80.9

M aterials
22 Casing Cast iron M.S.mating ring Ceramic
23 Impeller Bronze M.S.seal ring Carbon
24 Shaf t 403 Stainless steel
25 Casing ring Bronze
26 Ball bearing .
27 Mechanical seal .

M otor
28 Manuf acturer ATT Insulation class F
29 Ty pe 200LA_B3_37_3_400 Phases 3~
30 Specif ic design TEFC / 50 Hz / Pole pairs 1 Frame size 200 LA_37
31 Rated power kW 37 Weight kg 291
32 Number of poles 2 Electric v oltage V 400
33 Speed 1/min 2955 Electric current A 66.2
34 Degree of protection IP 55
35

Remarks
Performance curve Pump name 100x80 FS HCA

Customer Date 20-February -2019 Company


Contact Item no. Issued by
Phone Project Phone
E-mail Project ID E-mail

Requested data Pump


1 Flow m³/h 200 Operating Flow m³/h 200 Frequency Hz 50
2 Head m 45 Operating Head m 45.0 Number of poles 2
3 Static head m 0 Impeller Diameter Designed mm 203 Speed 1/min 2900

Test standard: ISO 9906:2012 - Grade3B Water, clean [100%] ; 20°C; 0.9983kg/dm³; 1mm²/s

Head

[m]

50

81.1% 45 m
1
Frequency
40

30
Ø 203.2

20

10

0
[kW]
Shaft power P2
Ø 203.2 (P2)

30 30.6 kW

20

10

0
[m] NPSH-values 80.9 %
[%] Efficiency Ø 203.2

Ø 203.2
60 4

3.31 m
40

20

200 m³/h
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 [m³/h]
Dimensions Pump name 100x80 FS HCA

Customer Date 20-February -2019 Company


Contact Item no. Issued by
Phone Project Phone
E-mail Project ID E-mail

T otal weight : 421 kg


Pum p dim ensi ons mm Suction si de mm Discharge si de mm

A 125 L 1259 D 100 D 80


B 360 MA 374.5 e 175 e 150
BC 275 MR 395.5 f 210 f 185
BJ 95 n 4 (Num) g 151 g 126
BL 1040 SA 100 h 19 h 19
BM 660 t 4 n Num 8 n Num 8
BN1 185 t 24 t 22
BN2 195 t1 2 t1 2
BY 1 440
BY 2 440
D 250
DA 80
Fd M16
(1/2)
Construction Pump name 100x80 FS HCA

Customer Date 20-February -2019 Company


Contact Item no. Issued by
Phone Project Phone
E-mail Project ID E-mail
(2/2)
Construction Pump name 100x80 FS HCA

Customer Date 20-February -2019 Company


Contact Item no. Issued by
Phone Project Phone
E-mail Project ID E-mail