Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 66

DESIGN OF BOX TYPE LINE DRAIN OF SIZE 0.

6m AND
HEIGHT UPTO 1.5m
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

DESIGN OF BOX TYPE DRAIN


0.60 m x 1.500 m

1.600 m
1.50 m 1.850 m
0.20 m 0.200 m
0.60 m Drain Base Width

0.200 m
1.000 m
0.400 m 0.400 m

0.800 m

Self weight of Earth = 2.00t/m3


Self weight of Concrete = 2.50t/m3

Grade of Concrete = M 25
Allowable Bending Stress scbc = 8.33 MPa
Grade of steel = Fe 500
Allowable stress in Steel = 240 MPa
Modular Ratio m = 10
n Neutral Axis depth factor = 0.258
j Leverarm factor = 0.914
Q Moment of Resistance factor = = 0.98 MPa

1 LOAD CALCULATION

1) Dead load

Wall
UDL of Vertical Walls 0.2 x 2.5 = in t/sq. m = = 0.5
Height of wall = 1.65 m
Weight of wall = 0.825 t/m

Base slab
UDL of Base Slab = 0.2 x 2.5 = 0.5
Length of slab = 1.00 m
Load = 0.50 t/m

0.100 m 0.100 m

0.800 m 1.600 m

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

0.83 t 0.83 t

0.000 t 0.000 t
0.50 t/m

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

2) Earth Pressure

Density of Soil = 2.0 t/m3


Angle of Internal Friction = 30 º
Surcharge Angle b = 0º
Wall Angle a = 90 º
SBC = 10 t/m2
Angle of Wall Friction d = 20 º
sin2 (   ) cos 1
Ka  x
sin2  sin( -  )  sin(   ) sin( -  ) 
2

1  
 sin( -  ) sin(   ) 

Earth pressure Coefficient = 0.279


Hence, Pressure at base of box = ###
Surcharge Height = ###
Pressure on Wall (1.2 x 0.279 x 2 ) = ###

settlement = 40 mm
Spring constant = 250.0 t/m2 per m width
No of Springs to be provided = 10 Nos
spring constant at end supports = 12.5 t/m depth per m width
spring constant at intermediate supports (adjacent to end support) = ### t/m depth per m width
spring constant at intermediate supports = ### t/m depth per m width

0.000
1.071 t
0.80 m 1.600 m
1.03m

0.67 m

1.032 t/m 0.67 t/m 0.67 t/m


Earth Surcharge 0.800 m Surcharge
Pressure Pressure Pressure

DL+SIDL
STAAD PLANE FRAME ANALYSIS FOR DRAIN OF SIZE 0.8 X 1.6
UNITS MTONS METERS
JOINT COORDINATES
1 0.00 0.00 0.00
2 0.800 0.00 0.00
4 0.00 1.600 0.00
3 0.800 1.600 0.00
Err:511
Err:511
7 0.800 0.100 0.00
8 0.00 0.100 0.00
Err:511
Err:511
Err:511
Err:511
Err:511
Err:511
MEMBER INCIDENCES

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

148
281
315
459
5 9 10
6 10 11
7 11 12
8 12 13
9 13 14
10 14 6
11 6 2
12 7 2
13 3 7
MEMBER PROPERTIES
3 11 PRIS YD 0.2 ZD 1.0
4 to 10 PRIS YD 0.2 ZD 1.0

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

1 13 PRIS YD 0.2 ZD 1.0


2 12 PRIS YD 0.2 ZD 1.0
CONSTANTS
E CONCRETE ALL
POISSON CONCRETE ALL
SUPPORTS
1 2 FIXED BUT FX FZ MX MY MZ KFY 12.500
5 6 FIXED BUT FX FZ MX MY MZ KFY 23.214
9 TO 14 FIXED BUT FX FZ MX MY MZ KFY 21.429
LOAD 1 DEAD LOADS
MEMBER LOADS
3 TO 11 UNI GY -0.500
3 CONC GY -0.000 0.100
11 CONC GY -0.000 0.000
1 13 CONC GY -0.825
LOAD 2 EARTH PRESSURES
MEMBER LOADS
1 TRAP GX 0 0.968
2 TRAP GX 0.968 1.032
13 TRAP GX 0 -0.968
12 TRAP GX -0.968 -1.032
1 TO 2 UNI GX 0.670
12 TO 13 UNI GX -0.670
LOAD COMB 3 LOAD COMBINATION
1 1.0 2 1.0
PERFORM ANALYSIS
PRINT ANALYSIS RESULTS
PRINT FORCE ENVELOPE NS 10
FINISH

2 ANALYSIS RESULTS

Description Base Slab Walls


Sl. No.
Moment-tm SF-d dist-t Moment-tm
1 Dead Load+Earth Pressures 1.23 0.75 1.12

3 DESIGN OF DRAIN
Design constants
Grade of Concrete = 25
M
Allowable Bending Stress (scbc) 8.33
= MPa
Grade of steel = 500
Fe
Allowable stress in Steel = MPa
240
modular Ratio (m) =
10
Neutral Axis depth factor (h) =
0.258
Leverarm factor (j) =
0.914
Moment of Resistance factor (Q) =
0.98 MPa

a) DESIGN OF BASE SLAB

Total moment on base slab due to Moment-tm Shear-t MAX Moment with impact-t
DL+Earth pressures 1.23 0.75
Net maximum moment on base slab = 1.23 t-m Clear Cover =
Hence, Effective Depth required = 111.8 mm
Total Depth Provided = 200 mm
Effective Cover = 80 mm
Hence, Effective Depth provided = 120 mm > Required, Hence, OK
Area of steel to be provided = 465.70 mm²

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

Minimum area of steel = 0.12% = 240.00 mm²


Provide TOR 10 dia @ 150 mm c/c 523 mm²
Shear check
Max. SF = 0.75 t
Shear Stress = 0.062MPa
For this percentage of steel, the allowable shear stress from table 11B of Amendments to IRC:21-1987
= 0.290MPa
> Actual, Hence OK

Distribution reinforcement = .2 DL Moment


= 0.25 t-m
Ast = 96.35 mm²
Provide 8 dia @ @ 521mm Provide @

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

b) DESIGN OF WALLS

Total moment on wall due to Moment-tm Shear-t Max Moment-tm


DL+Earth pressures 1.12 1.73

Net maximum moment on walls = 1.12 t-m Clear Cover =


Hence, Effective Depth required = 107 mm
Total Depth Provided = 200 mm
Effective Cover = 80 mm
Hence, Effective Depth provided = 120 mm > Required, Hence, OK
Area of steel to be provided = 424.30 mm²
Minimum area of steel = 0.12% = 240.00 mm²

Provide TOR 10 dia @ 150 mm c/c 523 mm²


Shear check
Max. SF = 1.73 t
Shear Stress = 0.144MPa
For this percentage of steel, the allowable shear stress from table 11B of Amendments to IRC:21-1987
= 0.290MPa
> Actual, Hence OK

Distribution reinforcement = .2 DL Moment


= 0.22 t-m
Ast = 87.79 mm²
Provide 8 dia @ @ 572mm Provide @

c) DESIGN OF TOP SLAB

Thickness of Top Slab = 150 mm


Span of Slab = 0.60 m
UDL of Top Slab = 0.375 t/m
Moment due to DL = 0.017 t/m
Footpath Live Load as per IRC:6-2010 = 0.400 t/m
Moment due to LL = 0.018 t/m
Total Bending Moment = 0.035 t-m
Effective Depth Required = 18.8 mm
Total Depth Provided = 150 mm Clear Cover =
Effective Cover = 55 mm
Effective Depth Provided = 95 mm > Required, Hence, OK
Area of steel to be provided = 16.73 mm²
Minimum area of steel = 0.12% = 180.00 mm²

Provide TOR 10 dia @ 150 mm c/c 523 mm²

Distribution reinforcement = .2 DL Moment + 0.3 LL Moment


= 0.01 t-m
Ast = 4.40 mm²
Provide 8 dia @ @ 11430mm Provide @

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

GN OF BOX TYPE DRAIN

Drain Base Width (Clear) 0.60


m
Drain Height (Clear) 1.50
m
Wall Thickness 0.20 m
Base Thickness 0.20 m
Top Slab Thickness 0.15 m

(IRC: 6 - 2010)

(Table 9 IRC 21-2000)

(Table 10 IRC 21-2000)


(Note 1Table 9 IRC 21-2000)

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

(IRC 6-2010 Cl. 217.1 )

(IRC 6-2010 Cl. 217.1 )

t/m depth per m width


t/m depth per m width
t/m depth per m width

1.032 t/m
Earth
Pressure

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

Walls
SF-d dist-t
1.73

MAX Moment with impact-tm

75.0 mm

> Required, Hence, OK

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

Percent = 0.44 %

r stress from table 11B of Amendments to IRC:21-1987

200mm

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

75.0 mm

> Required, Hence, OK

Percent = 0.44 %

r stress from table 11B of Amendments to IRC:21-1987

200mm

50.0 mm

> Required, Hence, OK

Percent = 0.55 %

200mm

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
DESIGN OF BOX TYPE LINE DRAIN OF SIZE 1.1m AND
HEIGHT UPTO 1.5m
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

DESIGN OF BOX TYPE DRAIN


1.10 m x 1.500 m

1.600 m
1.50 m 1.850 m
0.20 m 0.200 m
1.10 m Drain Base Width

0.200 m
1.500 m
0.650 m 0.650 m

1.300 m

Self weight of Earth = 2.00t/m3


Self weight of Concrete = 2.50t/m3

Grade of Concrete = M 25
Allowable Bending Stress scbc = 8.33 MPa
Grade of steel = Fe 500
Allowable stress in Steel = 240 MPa
Modular Ratio m = 10
n Neutral Axis depth factor = 0.258
j Leverarm factor = 0.914
Q Moment of Resistance factor = = 0.98 MPa

1 LOAD CALCULATION

1) Dead load

Wall
UDL of Vertical Walls 0.2 x 2.5 = in t/sq. m = = 0.5
Height of wall = 1.65 m
Weight of wall = 0.825 t/m

Base slab
UDL of Base Slab = 0.2 x 2.5 = 0.5
Length of slab = 1.50 m
Load = 0.75 t/m

0.100 m 0.100 m

1.300 m 1.600 m

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

0.83 t 0.83 t

0.000 t 0.000 t
0.50 t/m

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

2) Earth Pressure

Density of Soil = 2.0 t/m3


Angle of Internal Friction = 30 º
Surcharge Angle b = 0º
Wall Angle a = 90 º
SBC = 10 t/m2
Angle of Wall Friction d = 20 º
sin2 (   ) cos 1
Ka  x
sin2  sin( -  )  sin(   ) sin( -  ) 
2

1  
 sin( -  ) sin(   ) 

Earth pressure Coefficient = 0.279


Hence, Pressure at base of box = ###
Surcharge Height = ###
Pressure on Wall (1.2 x 0.279 x 2 ) = ###

settlement = 40 mm
Spring constant = 250.0 t/m2 per m width
No of Springs to be provided = 10 Nos
spring constant at end supports = 12.5 t/m depth per m width
spring constant at intermediate supports (adjacent to end support) = ### t/m depth per m width
spring constant at intermediate supports = ### t/m depth per m width

0.000
1.071 t
0.80 m 1.600 m
1.03m

0.67 m

1.032 t/m 0.67 t/m 0.67 t/m


Earth Surcharge 1.300 m Surcharge
Pressure Pressure Pressure

DL+SIDL
STAAD PLANE FRAME ANALYSIS FOR DRAIN OF SIZE 1.3 X 1.6
UNITS MTONS METERS
JOINT COORDINATES
1 0.00 0.00 0.00
2 1.300 0.00 0.00
4 0.00 1.600 0.00
3 1.300 1.600 0.00
Err:511
Err:511
7 1.300 0.100 0.00
8 0.00 0.100 0.00
Err:511
Err:511
Err:511
Err:511
Err:511
Err:511
MEMBER INCIDENCES

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

148
281
315
459
5 9 10
6 10 11
7 11 12
8 12 13
9 13 14
10 14 6
11 6 2
12 7 2
13 3 7
MEMBER PROPERTIES
3 11 PRIS YD 0.2 ZD 1.0
4 to 10 PRIS YD 0.2 ZD 1.0

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

1 13 PRIS YD 0.2 ZD 1.0


2 12 PRIS YD 0.2 ZD 1.0
CONSTANTS
E CONCRETE ALL
POISSON CONCRETE ALL
SUPPORTS
1 2 FIXED BUT FX FZ MX MY MZ KFY 12.500
5 6 FIXED BUT FX FZ MX MY MZ KFY 32.143
9 TO 14 FIXED BUT FX FZ MX MY MZ KFY 39.286
LOAD 1 DEAD LOADS
MEMBER LOADS
3 TO 11 UNI GY -0.500
3 CONC GY -0.000 0.100
11 CONC GY -0.000 0.000
1 13 CONC GY -0.825
LOAD 2 EARTH PRESSURES
MEMBER LOADS
1 TRAP GX 0 0.968
2 TRAP GX 0.968 1.032
13 TRAP GX 0 -0.968
12 TRAP GX -0.968 -1.032
1 TO 2 UNI GX 0.670
12 TO 13 UNI GX -0.670
LOAD COMB 3 LOAD COMBINATION
1 1.0 2 1.0
PERFORM ANALYSIS
PRINT ANALYSIS RESULTS
PRINT FORCE ENVELOPE NS 10
FINISH

2 ANALYSIS RESULTS

Description Base Slab Walls


Sl. No.
Moment-tm SF-d dist-t Moment-tm
1 Dead Load+Earth Pressures 1.22 0.79 1.12

3 DESIGN OF DRAIN
Design constants
Grade of Concrete = 25
M
Allowable Bending Stress (scbc) 8.33
= MPa
Grade of steel = 500
Fe
Allowable stress in Steel = MPa
240
modular Ratio (m) =
10
Neutral Axis depth factor (h) =
0.258
Leverarm factor (j) =
0.914
Moment of Resistance factor (Q) =
0.98 MPa

a) DESIGN OF BASE SLAB

Total moment on base slab due to Moment-tm Shear-t MAX Moment with impact-t
DL+Earth pressures 1.22 0.79
Net maximum moment on base slab = 1.22 t-m Clear Cover =
Hence, Effective Depth required = 111.6 mm
Total Depth Provided = 200 mm
Effective Cover = 80 mm
Hence, Effective Depth provided = 120 mm > Required, Hence, OK
Area of steel to be provided = 464.18 mm²

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

Minimum area of steel = 0.12% = 240.00 mm²


Provide TOR 10 dia @ 150 mm c/c 523 mm²
Shear check
Max. SF = 0.79 t
Shear Stress = 0.066MPa
For this percentage of steel, the allowable shear stress from table 11B of Amendments to IRC:21-1987
= 0.290MPa
> Actual, Hence OK

Distribution reinforcement = .2 DL Moment


= 0.24 t-m
Ast = 96.04 mm²
Provide 8 dia @ @ 523mm Provide @

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

b) DESIGN OF WALLS

Total moment on wall due to Moment-tm Shear-t Max Moment-tm


DL+Earth pressures 1.12 1.73

Net maximum moment on walls = 1.12 t-m Clear Cover =


Hence, Effective Depth required = 107 mm
Total Depth Provided = 200 mm
Effective Cover = 80 mm
Hence, Effective Depth provided = 120 mm > Required, Hence, OK
Area of steel to be provided = 424.30 mm²
Minimum area of steel = 0.12% = 240.00 mm²

Provide TOR 10 dia @ 150 mm c/c 523 mm²


Shear check
Max. SF = 1.73 t
Shear Stress = 0.144MPa
For this percentage of steel, the allowable shear stress from table 11B of Amendments to IRC:21-1987
= 0.290MPa
> Actual, Hence OK

Distribution reinforcement = .2 DL Moment


= 0.22 t-m
Ast = 87.79 mm²
Provide 8 dia @ @ 572mm Provide @

c) DESIGN OF TOP SLAB

Thickness of Top Slab = 150 mm


Span of Slab = 1.10 m
UDL of Top Slab = 0.375 t/m
Moment due to DL = 0.057 t/m
Footpath Live Load as per IRC:6-2010 = 0.400 t/m
Moment due to LL = 0.061 t/m
Total Bending Moment = 0.117 t-m
Effective Depth Required = 34.6 mm
Total Depth Provided = 150 mm Clear Cover =
Effective Cover = 55 mm
Effective Depth Provided = 95 mm > Required, Hence, OK
Area of steel to be provided = 56.24 mm²
Minimum area of steel = 0.12% = 180.00 mm²

Provide TOR 10 dia @ 150 mm c/c 523 mm²

Distribution reinforcement = .2 DL Moment + 0.3 LL Moment


= 0.03 t-m
Ast = 14.77 mm²
Provide 8 dia @ @ 3401mm Provide @

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

GN OF BOX TYPE DRAIN

Drain Base Width (Clear) 1.10


m
Drain Height (Clear) 1.50
m
Wall Thickness 0.20 m
Base Thickness 0.20 m
Top Slab Thickness 0.15 m

(IRC: 6 - 2010)

(Table 9 IRC 21-2000)

(Table 10 IRC 21-2000)


(Note 1Table 9 IRC 21-2000)

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

(IRC 6-2010 Cl. 217.1 )

(IRC 6-2010 Cl. 217.1 )

t/m depth per m width


t/m depth per m width
t/m depth per m width

1.032 t/m
Earth
Pressure

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

Walls
SF-d dist-t
1.73

MAX Moment with impact-tm

75.0 mm

> Required, Hence, OK

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

Percent = 0.44 %

r stress from table 11B of Amendments to IRC:21-1987

200mm

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

75.0 mm

> Required, Hence, OK

Percent = 0.44 %

r stress from table 11B of Amendments to IRC:21-1987

200mm

50.0 mm

> Required, Hence, OK

Percent = 0.55 %

200mm

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

DESIGN OF BOX TYPE DRAIN


1.10 m x 1.500 m

1.600 m
1.50 m 1.700 m
0.20 m 0.200 m
1.10 m Drain Base Width

0.200 m
1.500 m
0.650 m 0.650 m

1.300 m

Self weight of Earth = 2.00t/m3


Self weight of Concrete = 2.50t/m3

Grade of Concrete = M 20
Allowable Bending Stress scbc = 6.67 MPa
Grade of steel = Fe 500
Allowable stress in Steel = 240 MPa
Modular Ratio m = 10
n Neutral Axis depth factor = 0.217
j Leverarm factor = 0.928
Q Moment of Resistance factor = = 0.67 MPa

1 LOAD CALCULATION

1) Dead load

Wall
UDL of Vertical Walls 0.2 x 2.5 = in t/sq. m = = 0.5
Height of wall = 1.50 m
Weight of wall = 0.750 t/m

Base slab
UDL of Base Slab = 0.2 x 2.5 = 0.5
Length of slab = 1.50 m
Load = 0.75 t/m

0.100 m 0.100 m

1.300 m 1.600 m

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

0.75 t 0.75 t

0.000 t 0.000 t
0.50 t/m

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

2) Earth Pressure

Density of Soil = 2.0 t/m3


Angle of Internal Friction = 30 º
Surcharge Angle b = 0º
Wall Angle a = 90 º
SBC = 10 t/m2
Angle of Wall Friction d = 20 º
sin2 (   ) cos 1
Ka  x
sin2  sin( -  )  sin(   ) sin( -  ) 
2

1  
 sin( -  ) sin(   ) 

Earth pressure Coefficient = 0.279


Hence, Pressure at base of box = ###
Surcharge Height = ###
Pressure on Wall (1.2 x 0.279 x 2 ) = ###

settlement = 40 mm
Spring constant = 250.0 t/m2 per m width
No of Springs to be provided = 10 Nos
spring constant at end supports = 12.5 t/m depth per m width
spring constant at intermediate supports (adjacent to end support) = ### t/m depth per m width
spring constant at intermediate supports = ### t/m depth per m width

0.000
1.071 t
0.80 m 1.600 m
0.89m

0.67 m

0.893 t/m 0.67 t/m 0.67 t/m


Earth Surcharge 1.300 m Surcharge
Pressure Pressure Pressure

DL+SIDL
STAAD PLANE FRAME ANALYSIS FOR DRAIN OF SIZE 1.3 X 1.6
UNITS MTONS METERS
JOINT COORDINATES
1 0.00 0.00 0.00
2 1.300 0.00 0.00
4 0.00 1.600 0.00
3 1.300 1.600 0.00
Err:511
Err:511
7 1.300 0.100 0.00
8 0.00 0.100 0.00
Err:511
Err:511
Err:511
Err:511
Err:511
Err:511
MEMBER INCIDENCES

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

148
281
315
459
5 9 10
6 10 11
7 11 12
8 12 13
9 13 14
10 14 6
11 6 2
12 7 2
13 3 7
MEMBER PROPERTIES
3 11 PRIS YD 0.2 ZD 1.0
4 to 10 PRIS YD 0.2 ZD 1.0

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

1 13 PRIS YD 0.2 ZD 1.0


2 12 PRIS YD 0.2 ZD 1.0
CONSTANTS
E CONCRETE ALL
POISSON CONCRETE ALL
SUPPORTS
1 2 FIXED BUT FX FZ MX MY MZ KFY 12.500
5 6 FIXED BUT FX FZ MX MY MZ KFY 32.143
9 TO 14 FIXED BUT FX FZ MX MY MZ KFY 39.286
LOAD 1 DEAD LOADS
MEMBER LOADS
3 TO 11 UNI GY -0.500
3 CONC GY -0.000 0.100
11 CONC GY -0.000 0.000
1 13 CONC GY -0.750
LOAD 2 EARTH PRESSURES
MEMBER LOADS
1 TRAP GX 0 0.837
2 TRAP GX 0.837 0.893
13 TRAP GX 0 -0.837
12 TRAP GX -0.837 -0.893
1 TO 2 UNI GX 0.670
12 TO 13 UNI GX -0.670
LOAD COMB 3 LOAD COMBINATION
1 1.0 2 1.0
PERFORM ANALYSIS
PRINT ANALYSIS RESULTS
PRINT FORCE ENVELOPE NS 10
FINISH

2 ANALYSIS RESULTS

Description Base Slab Walls


Sl. No.
Moment-tm SF-d dist-t Moment-tm
1 Dead Load+Earth Pressures 1.17 0.72 1.07

3 DESIGN OF DRAIN
Design constants
Grade of Concrete = 20
M
Allowable Bending Stress (scbc) 6.67
= MPa
Grade of steel = 500
Fe
Allowable stress in Steel = MPa
240
modular Ratio (m) =
10
Neutral Axis depth factor (h) =
0.217
Leverarm factor (j) =
0.928
Moment of Resistance factor (Q) =
0.67 MPa

a) DESIGN OF BASE SLAB

Total moment on base slab due to Moment-tm Shear-t MAX Moment with impact-t
DL+Earth pressures 1.17 0.72
Net maximum moment on base slab = 1.17 t-m
Hence, Effective Depth required = 131.9 mm
Total Depth Provided = 200 mm
Effective Cover = 55 mm
Hence, Effective Depth provided = 145 mm > Required, Hence, OK
Area of steel to be provided = 362.16 mm²

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

Minimum area of steel = 0.12% = 174.00 mm²


Provide TOR 10 dia @ 150 mm c/c 523 mm²
Shear check
Max. SF = 0.72 t
Shear Stress = 0.050MPa
For this percentage of steel, the allowable shear stress from table 11B of Amendments to IRC:21-1987
= 0.255MPa
> Actual, Hence OK

Distribution reinforcement = .2 DL Moment


= 0.23 t-m
Ast = 74.49 mm²
Provide 8 dia @ @ 674mm Provide @

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

b) DESIGN OF WALLS

Total moment on wall due to Moment-tm Shear-t Max Moment-tm


DL+Earth pressures 1.07 1.63

Net maximum moment on walls = 1.07 t-m


Hence, Effective Depth required = 126 mm
Total Depth Provided = 200 mm
Effective Cover = 55 mm
Hence, Effective Depth provided = 145 mm > Required, Hence, OK
Area of steel to be provided = 330.87 mm²
Minimum area of steel = 0.12% = 174.00 mm²

Provide TOR 10 dia @ 150 mm c/c 523 mm²


Shear check
Max. SF = 1.63 t
Shear Stress = 0.113MPa
For this percentage of steel, the allowable shear stress from table 11B of Amendments to IRC:21-1987
= 0.255MPa
> Actual, Hence OK

Distribution reinforcement = .2 DL Moment


= 0.21 t-m
Ast = 68.05 mm²
Provide 8 dia @ @ 738mm Provide @

c) DESIGN OF TOP SLAB

Thickness of Top Slab = 150 mm


UDL of Top Slab = 0.375 t/m
Footpath Live Load as per IRC:6-2010 = 0.400 t/m
Total Load = 0.775 t/m
Span of Slab = 1.10 m
Bending Moment = 0.117 t-m
Effective Depth Required = 41.8 mm
Total Depth Provided = 150 mm
Effective Cover = 50 mm
Effective Depth Provided = 100 mm > Required, Hence, OK
Area of steel to be provided = 52.66 mm²
Minimum area of steel = 0.12% = 120.00 mm²

Provide TOR 10 dia @ 150 mm c/c 523 mm²

Distribution reinforcement = .2 DL Moment


= 0.02 t-m
Ast = 10.97 mm²
Provide 8 dia @ @ 4580mm Provide @

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

GN OF BOX TYPE DRAIN

Drain Base Width (Clear) 1.10


m
Drain Height (Clear) 1.50
m
Wall Thickness 0.20 m
Base Thickness 0.20 m
Top Slab Thickness 0.15 m

(IRC: 6 - 2010)

(Table 9 IRC 21-2000)

(Table 10 IRC 21-2000)


(Note 1Table 9 IRC 21-2000)

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

(IRC 6-2010 Cl. 217.1 )

(IRC 6-2010 Cl. 217.1 )

t/m depth per m width


t/m depth per m width
t/m depth per m width

0.89 t/m
Earth
Pressure

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

Walls
SF-d dist-t
1.63

MAX Moment with impact-tm

> Required, Hence, OK

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

Percent = 0.36 %

r stress from table 11B of Amendments to IRC:21-1987

200mm

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
Detailed Design for 6 loaning of Hosur- Krishnagiri Section of NH-7

> Required, Hence, OK

Percent = 0.36 %

r stress from table 11B of Amendments to IRC:21-1987

200mm

> Required, Hence, OK

Percent = 0.52 %

200mm

DESIGN OF BOX TYPE DRAIN


H K Toll Road Pvt. Ltd.
REVISION : R0
DESIGN OF DRAIN
0.60 m x 1.000 m

1.100 m
1.00 m 1.200 m
0.20 m 0.200 m
0.60 m Drain Base Width (

0.200 m
1.000 m
0.400 m 0.400 m

0.800 m

Self weight of Earth = 2.00t/m3


Self weight of Concrete = 2.50t/m3

Grade of Concrete = M 25
Allowable Bending Stress scbc = 8.33 MPa
Grade of steel = Fe 500
Allowable stress in Steel = 240 MPa
Modular Ratio m = 10
n Neutral Axis depth factor = 0.258
j Leverarm factor = 0.914
Q Moment of Resistance factor = = 0.98 MPa

1 LOAD CALCULATION

1) Dead load

Wall
UDL of Vertical Walls 0.2 x 2.5 = in t/sq. m = = 0.5
Height of wall = 1.00 m
Weight of wall = 0.500 t/m

Base slab
UDL of Base Slab = 0.2 x 2.5 = 0.5
Length of slab = 1.00 m
Load = 0.50 t/m

Feedback Infra Privet Limited


0.100 m 0.100 m

0.800 m 1.100 m

0.50 t 0.50 t

0.000 t 0.000 t
0.50 t/m

Feedback Infra Privet Limited


2) Earth Pressure

Density of Soil = 2.0 t/m3


Angle of Internal Friction = 30 º
Surcharge Angle b = 0º
Wall Angle a = 90 º
SBC = 10 t/m2
Angle of Wall Friction d = 20 º
sin 2 (   ) cos 1
Ka  x
sin2  sin( -  )  sin(   ) sin( -  ) 
2

1  
 sin( -  ) sin(   ) 

Earth pressure Coefficient = 0.279


Hence, Pressure at base of box = ###
Surcharge Height = ###
Pressure on Wall (1.2 x 0.279 x 2 ) = ###

settlement = 40 mm
Spring constant = 250.0 t/m2 per m width
No of Springs to be provided = 10 Nos
spring constant at end supports = 12.5 t/m depth per m width
spring constant at intermediate supports (adjacent to end support) = ### t/m depth per m width
spring constant at intermediate supports = ### t/m depth per m width

0.000
0.737 t
0.55 m 1.100 m
0.61m

0.46 m

0.614 t/m 0.67 t/m 0.67 t/m


Earth Surcharge 0.800 m Surcharge
Pressure Pressure Pressure

DL+SIDL
STAAD PLANE FRAME ANALYSIS FOR DRAIN OF SIZE 0.8 X 1.1
UNITS MTONS METERS
JOINT COORDINATES
1 0.00 0.00 0.00
2 0.800 0.00 0.00
4 0.00 1.100 0.00
3 0.800 1.100 0.00
Err:511
Err:511
7 0.800 0.100 0.00
8 0.00 0.100 0.00
Err:511
Err:511
Err:511

Feedback Infra Privet Limited


Err:511
Err:511
Err:511
MEMBER INCIDENCES
148
281
315
459
5 9 10
6 10 11
7 11 12
8 12 13
9 13 14

Feedback Infra Privet Limited


10 14 6
11 6 2
12 7 2
13 3 7
MEMBER PROPERTIES
3 11 PRIS YD 0.2 ZD 1.0
4 to 10 PRIS YD 0.2 ZD 1.0
1 13 PRIS YD 0.2 ZD 1.0
2 12 PRIS YD 0.2 ZD 1.0
CONSTANTS
E CONCRETE ALL
POISSON CONCRETE ALL
SUPPORTS
1 2 FIXED BUT FX FZ MX MY MZ KFY 12.500
5 6 FIXED BUT FX FZ MX MY MZ KFY 23.214
9 TO 14 FIXED BUT FX FZ MX MY MZ KFY 21.429
LOAD 1 DEAD LOADS
MEMBER LOADS
3 TO 11 UNI GY -0.500
3 CONC GY -0.000 0.100
11 CONC GY -0.000 0.000
1 13 CONC GY -0.500
LOAD 2 EARTH PRESSURES
MEMBER LOADS
1 TRAP GX 0 0.558
2 TRAP GX 0.558 0.614
13 TRAP GX 0 -0.558
12 TRAP GX -0.558 -0.614
1 TO 2 UNI GX 0.670
12 TO 13 UNI GX -0.670
LOAD COMB 3 LOAD COMBINATION
1 1.0 2 1.0
PERFORM ANALYSIS
PRINT ANALYSIS RESULTS
PRINT FORCE ENVELOPE NS 10
FINISH

2 ANALYSIS RESULTS

Description Base Slab Walls


Sl. No.
Moment-tm SF-d dist-t Moment-tm
1 Dead Load+Earth Pressures 0.49 0.46 0.43

3 DESIGN OF DRAIN
Design constants
Grade of Concrete = 25
M
Allowable Bending Stress (scbc) 8.33
= MPa
Grade of steel = 500
Fe
Allowable stress in Steel = MPa
240
modular Ratio (m) =
10
Neutral Axis depth factor (h) =
0.258
Leverarm factor (j) =
0.914
Moment of Resistance factor (Q) =
0.98 MPa

Feedback Infra Privet Limited


a) DESIGN OF BASE SLAB

Total moment on base slab due to Moment-tm Shear-t MAX Moment with impact-tm
DL+Earth pressures 0.49 0.46
Net maximum moment on base slab = 0.49 t-m
Hence, Effective Depth required = 70.3 mm
Total Depth Provided = 200 mm
Effective Cover = 30 mm
Hence, Effective Depth provided = 170 mm > Required, Hence, OK
Area of steel to be provided = 130.04 mm²
Minimum area of steel = 0.12% = 204.00 mm²
Provide TOR 10 dia @ 150 mm c/c 523 mm²

Feedback Infra Privet Limited


Shear check
Max. SF = 0.46 t
Shear Stress = 0.027MPa
For this percentage of steel, the allowable shear stress from table 11B of Amendments to IRC:21-1987
= 0.249MPa
> Actual, Hence OK

Distribution reinforcement = .2 DL Moment


= 0.10 t-m
Ast = 26.64 mm²
Provide 8 dia @ @ 1886mm Provide @

b) DESIGN OF WALLS

Total moment on wall due to Moment-tm Shear-t Max Moment-tm


DL+Earth pressures 0.43 0.95

Net maximum moment on walls = 0.43 t-m


Hence, Effective Depth required = 66 mm
Total Depth Provided = 200 mm
Effective Cover = 55 mm
Hence, Effective Depth provided = 145 mm > Required, Hence, OK
Area of steel to be provided = 134.55 mm²
Minimum area of steel = 0.12% = 174.00 mm²

Provide TOR 10 dia @ 150 mm c/c 523 mm²


Shear check
Max. SF = 0.95 t
Shear Stress = 0.065MPa
For this percentage of steel, the allowable shear stress from table 11B of Amendments to IRC:21-1987
= 0.265MPa
> Actual, Hence OK

Distribution reinforcement = .2 DL Moment


= 0.09 t-m
Ast = 27.67 mm²
Provide 8 dia @ @ 1815mm Provide @

c) DESIGN OF TOP SLAB

Thickness of Top Slab = 150 mm


UDL of Top Slab = 0.375 t/m
Footpath Live Load as per IRC:6-2010 = 0.400 t/m
Total Load = 0.775 t/m
Span of Slab = 0.60 m
Bending Moment = 0.035 t-m
Effective Depth Required = 18.8 mm
Total Depth Provided = 150 mm
Effective Cover = 50 mm
Effective Depth Provided = 100 mm > Required, Hence, OK
Area of steel to be provided = 15.90 mm²
Minimum area of steel = 0.12% = 120.00 mm²

Provide TOR 10 dia @ 150 mm c/c 523 mm²

Feedback Infra Privet Limited


Distribution reinforcement = .2 DL Moment
= 0.01 t-m
Ast = 3.31 mm²
Provide 8 dia @ @ 15170mm Provide @

Feedback Infra Privet Limited


DESIGN OF DRAIN

Drain Base Width (Clear) 0.60 m


Drain Height (Clear) 1.00 m
Wall Thickness 0.20 m
Base Thickness 0.20 m
Top Slab Thickness 0.15 m

(IRC: 6 - 2010)

(Table 9 IRC 21-2000)

(Table 10 IRC 21-2000)


(Note 1Table 9 IRC 21-2000)

Feedback Infra Privet Limited


(IRC 6-2010 Cl. 217.1 )

(IRC 6-2010 Cl. 217.1 )

t/m depth per m width


t/m depth per m width
t/m depth per m width

0.61 t/m
Earth
Pressure

Feedback Infra Privet Limited


Walls
SF-d dist-t
0.95

Feedback Infra Privet Limited


MAX Moment with impact-tm

> Required, Hence, OK

Percent = 0.31 %

Feedback Infra Privet Limited


ear stress from table 11B of Amendments to IRC:21-1987

200mm

> Required, Hence, OK

Percent = 0.36 %

ear stress from table 11B of Amendments to IRC:21-1987

200mm

> Required, Hence, OK

Percent = 0.52 %

Feedback Infra Privet Limited


200mm

Feedback Infra Privet Limited


DESIGN OF DRAIN
1.10 m x 1.000 m

1.100 m
1.00 m 1.200 m
0.20 m 0.200 m
1.10 m Drain Base Width (

0.200 m
1.500 m
0.650 m 0.650 m

1.300 m

Self weight of Earth = 2.00t/m3


Self weight of Concrete = 2.50t/m3

Grade of Concrete = M 25
Allowable Bending Stress scbc = 8.33 MPa
Grade of steel = Fe 500
Allowable stress in Steel = 240 MPa
Modular Ratio m = 10
n Neutral Axis depth factor = 0.258
j Leverarm factor = 0.914
Q Moment of Resistance factor = = 0.98 MPa

1 LOAD CALCULATION

1) Dead load

Wall
UDL of Vertical Walls 0.2 x 2.5 = in t/sq. m = = 0.5
Height of wall = 1.00 m
Weight of wall = 0.500 t/m

Base slab
UDL of Base Slab = 0.2 x 2.5 = 0.5
Length of slab = 1.50 m
Load = 0.75 t/m

Feedback Infra Privet Limited


0.100 m 0.100 m

1.300 m 1.100 m

0.50 t 0.50 t

0.000 t 0.000 t
0.50 t/m

Feedback Infra Privet Limited


2) Earth Pressure

Density of Soil = 2.0 t/m3


Angle of Internal Friction = 30 º
Surcharge Angle b = 0º
Wall Angle a = 90 º
SBC = 10 t/m2
Angle of Wall Friction d = 20 º
sin 2 (   ) cos 1
Ka  x
sin2  sin( -  )  sin(   ) sin( -  ) 
2

1  
 sin( -  ) sin(   ) 

Earth pressure Coefficient = 0.279


Hence, Pressure at base of box = ###
Surcharge Height = ###
Pressure on Wall (1.2 x 0.279 x 2 ) = ###

settlement = 40 mm
Spring constant = 250.0 t/m2 per m width
No of Springs to be provided = 10 Nos
spring constant at end supports = 12.5 t/m depth per m width
spring constant at intermediate supports (adjacent to end support) = ### t/m depth per m width
spring constant at intermediate supports = ### t/m depth per m width

0.000
0.737 t
0.55 m 1.100 m
0.61m

0.46 m

0.614 t/m 0.67 t/m 0.67 t/m


Earth Surcharge 1.300 m Surcharge
Pressure Pressure Pressure

DL+SIDL
STAAD PLANE FRAME ANALYSIS FOR DRAIN OF SIZE 1.3 X 1.1
UNITS MTONS METERS
JOINT COORDINATES
1 0.00 0.00 0.00
2 1.300 0.00 0.00
4 0.00 1.100 0.00
3 1.300 1.100 0.00
Err:511
Err:511
7 1.300 0.100 0.00
8 0.00 0.100 0.00
Err:511
Err:511
Err:511

Feedback Infra Privet Limited


Err:511
Err:511
Err:511
MEMBER INCIDENCES
148
281
315
459
5 9 10
6 10 11
7 11 12
8 12 13
9 13 14

Feedback Infra Privet Limited


10 14 6
11 6 2
12 7 2
13 3 7
MEMBER PROPERTIES
3 11 PRIS YD 0.2 ZD 1.0
4 to 10 PRIS YD 0.2 ZD 1.0
1 13 PRIS YD 0.2 ZD 1.0
2 12 PRIS YD 0.2 ZD 1.0
CONSTANTS
E CONCRETE ALL
POISSON CONCRETE ALL
SUPPORTS
1 2 FIXED BUT FX FZ MX MY MZ KFY 12.500
5 6 FIXED BUT FX FZ MX MY MZ KFY 32.143
9 TO 14 FIXED BUT FX FZ MX MY MZ KFY 39.286
LOAD 1 DEAD LOADS
MEMBER LOADS
3 TO 11 UNI GY -0.500
3 CONC GY -0.000 0.100
11 CONC GY -0.000 0.000
1 13 CONC GY -0.500
LOAD 2 EARTH PRESSURES
MEMBER LOADS
1 TRAP GX 0 0.558
2 TRAP GX 0.558 0.614
13 TRAP GX 0 -0.558
12 TRAP GX -0.558 -0.614
1 TO 2 UNI GX 0.670
12 TO 13 UNI GX -0.670
LOAD COMB 3 LOAD COMBINATION
1 1.0 2 1.0
PERFORM ANALYSIS
PRINT ANALYSIS RESULTS
PRINT FORCE ENVELOPE NS 10
FINISH

2 ANALYSIS RESULTS

Description Base Slab Walls


Sl. No.
Moment-tm SF-d dist-t Moment-tm
1 Dead Load+Earth Pressures 0.48 0.49 0.43

3 DESIGN OF DRAIN
Design constants
Grade of Concrete = 25
M
Allowable Bending Stress (scbc) 8.33
= MPa
Grade of steel = 500
Fe
Allowable stress in Steel = MPa
240
modular Ratio (m) =
10
Neutral Axis depth factor (h) =
0.258
Leverarm factor (j) =
0.914
Moment of Resistance factor (Q) =
0.98 MPa

Feedback Infra Privet Limited


a) DESIGN OF BASE SLAB

Total moment on base slab due to Moment-tm Shear-t MAX Moment with impact-tm
DL+Earth pressures 0.48 0.49
Net maximum moment on base slab = 0.48 t-m
Hence, Effective Depth required = 70.1 mm
Total Depth Provided = 200 mm
Effective Cover = 30 mm
Hence, Effective Depth provided = 170 mm > Required, Hence, OK
Area of steel to be provided = 129.51 mm²
Minimum area of steel = 0.12% = 204.00 mm²
Provide TOR 10 dia @ 150 mm c/c 523 mm²

Feedback Infra Privet Limited


Shear check
Max. SF = 0.49 t
Shear Stress = 0.029MPa
For this percentage of steel, the allowable shear stress from table 11B of Amendments to IRC:21-1987
= 0.249MPa
> Actual, Hence OK

Distribution reinforcement = .2 DL Moment


= 0.10 t-m
Ast = 26.53 mm²
Provide 8 dia @ @ 1894mm Provide @

b) DESIGN OF WALLS

Total moment on wall due to Moment-tm Shear-t Max Moment-tm


DL+Earth pressures 0.43 0.95

Net maximum moment on walls = 0.43 t-m


Hence, Effective Depth required = 66 mm
Total Depth Provided = 200 mm
Effective Cover = 55 mm
Hence, Effective Depth provided = 145 mm > Required, Hence, OK
Area of steel to be provided = 134.55 mm²
Minimum area of steel = 0.12% = 174.00 mm²

Provide TOR 10 dia @ 150 mm c/c 523 mm²


Shear check
Max. SF = 0.95 t
Shear Stress = 0.065MPa
For this percentage of steel, the allowable shear stress from table 11B of Amendments to IRC:21-1987
= 0.265MPa
> Actual, Hence OK

Distribution reinforcement = .2 DL Moment


= 0.09 t-m
Ast = 27.67 mm²
Provide 8 dia @ @ 1815mm Provide @

c) DESIGN OF TOP SLAB

Thickness of Top Slab = 150 mm


UDL of Top Slab = 0.375 t/m
Footpath Live Load as per IRC:6-2010 = 0.400 t/m
Total Load = 0.775 t/m
Span of Slab = 1.10 m
Bending Moment = 0.117 t-m
Effective Depth Required = 34.6 mm
Total Depth Provided = 150 mm
Effective Cover = 50 mm
Effective Depth Provided = 100 mm > Required, Hence, OK
Area of steel to be provided = 53.43 mm²
Minimum area of steel = 0.12% = 120.00 mm²

Provide TOR 10 dia @ 150 mm c/c 523 mm²

Feedback Infra Privet Limited


Distribution reinforcement = .2 DL Moment
= 0.02 t-m
Ast = 11.13 mm²
Provide 8 dia @ @ 4513mm Provide @

Feedback Infra Privet Limited


DESIGN OF DRAIN

Drain Base Width (Clear) 1.10 m


Drain Height (Clear) 1.00 m
Wall Thickness 0.20 m
Base Thickness 0.20 m
Top Slab Thickness 0.15 m

(IRC: 6 - 2010)

(Table 9 IRC 21-2000)

(Table 10 IRC 21-2000)


(Note 1Table 9 IRC 21-2000)

Feedback Infra Privet Limited


(IRC 6-2010 Cl. 217.1 )

(IRC 6-2010 Cl. 217.1 )

t/m depth per m width


t/m depth per m width
t/m depth per m width

0.61 t/m
Earth
Pressure

Feedback Infra Privet Limited


Walls
SF-d dist-t
0.95

Feedback Infra Privet Limited


MAX Moment with impact-tm

> Required, Hence, OK

Percent = 0.31 %

Feedback Infra Privet Limited


ear stress from table 11B of Amendments to IRC:21-1987

200mm

> Required, Hence, OK

Percent = 0.36 %

ear stress from table 11B of Amendments to IRC:21-1987

200mm

> Required, Hence, OK

Percent = 0.52 %

Feedback Infra Privet Limited


200mm

Feedback Infra Privet Limited

You might also like