AIM
To find out the horizontal component of earth’s magnetic field (H).
Materials Required
Tangent Galvanometer Ammeter Rheostat Spirit Level
Therefore,
the Reduction Factor of the Tangent Galvanometer is defined
as the current in amperes which when passed through the
tangent galvanometer produces a deflection of 45°.
i.e. F = H tanθ mF
S A
For the tangent galvanometer we have the relation
I = K tanθ …..(i) mH
H = µ°2πnI
4πr tan θ
- Hence Proved
From the above equation it is also clear that the graph of tanθ vs. I would
be a straight line with a slope = µ° 2πn / 4πr H.
Make the circuit connections in accordance with the diagram connecting the
positive terminal of the ammeter to the higher potential terminal of the battery and
using 50 turns in the coil of the tangent galvanometer.
Note the least count and the zero error of the ammeter.
Measure the inner and the outer diameter of the coil of the tangent
galvanometer three times with a meter scale.
Make the initial setting in the tangent galvanometer.
Switch on the current through the galvanometer by closing the key K. Read
both ends of the pointer after gently trapping the compass box. Using the
reversing key (R.K.), reverse the direction of the current through the coil and
again read the values of the deflection shown by the pointer in the to cases (i.e.,
before and after reversing the current) differ by more then 1°, then turn slightly
the vertical coil until the two value agree. This will set the plane of the coil
exactly in the magnetic meridian. Now mark the positions of the leveling screws
on the working table with a piece of chalk.
Bring the deflection in the galvanometer reading around 45° by adjusting
rheostat suitably & in on case the deflection should be outside range (30° - 60°).
Record the readings of the ammeter and the deflection of the
compass needle shown by the two ends of the aluminum pointer on
the scale.
Now reverse the current through the coil of the tangent
galvanometer by turning the reversing key & record the values of
current & deflection of the compass needle as shown in above step.
Change the current through the coil of the tangent galvanometer
by shifting the position of rheostat in such a way that the
deflection lies within (30° - 60°) range and record the readings as
explained in above two steps.
By changing the value of current through the coil, take fore more
sets of observations keeping the deflection within 30° - 60° range.
Measure the inner and outer diameters of the coil with a meter
scale at least two times.
Record your observations .
Range of the ammeter = Least count of the ammeter =
= tanθ / I
=m
=
Now, substituting the value of m in the equation
m = µ° 2πn / 4πr H
H=
H=
The value of the horizontal component of Earth’s magnetic
field is
Make sure that the connections are neat and tight and the plugs are not loose.
The battery or accumulator used should be freshly charged.
The reversing key should be switched off when the readings are not being taken.
The magnetic needle should swing freely in the horizontal plane. Leveling and other
setting for this purpose should be done carefully.
All the magnetic materials and current carrying wires should be carefully set in the
magnetic meridian. This is the most essential requirement of this experiment.
Both the ends of the pointer should be read for direct as well as reverse current and the
mean of the four readings should be used.
While noting down the deflection of the pointer ends, error due to parallax should be
avoided
and the compass box should be gently tapped before taking each reading.
All values of deflection should be adjusted between 30° and 60° as the measurement of
the instrument is maximum when the deflection is around 45°.